The resulting emissions of the firing of ceramic products of all type are described, the factors are enumerated to diminish the emissions in the kilns and the technologies applied in the kilns to reduce these emissions while carrying out energy saving are described briefly. (author)
In the last issue of 'L'Industrie ceramique et verriere', we presented the first part of this study. We describe in this issue the experimental procedure, the results and the conclusions of this work. (authors)
The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.
This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements require a linear filter combined with a ...
This document deals with the couplings between the W boson and Z and gamma particles. WWZ and WW{gamma} vertex are predicted by the electroweak theory based on the symmetry group SU(2){sub L}*U(1){sub Y}, their existence is confirmed by the measurement of the production cross-section of W pairs at LEP. The effective values of the couplings are modified by the introduction of standard model particle loops at the vertex level, the impact on the coupling value is assessed to reach 10{sup -3}. These loops can also include beyond-the-standard-model particles, their impact is in the magnitude order of 10{sup -3} for most models. The fully description of these loops requires the values of 14 complex parameters whose measurement will give information about the existence of new particles. Nevertheless the number of events at LEP is not sufficient to measure all the parameters simultaneously. As a consequence the analysis is limited to the 3 most promising parameters: g{sub 1}{sup Z}, ...
This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...
The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)
This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was measured by gamma spectroscopy of irradiated ...
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without ...
The aim of the thesis is to validate concepts used in hydrocarbon generation and migration models; the model considered is the Temispack model developed by IFP, and the validation is based on the investigation of the thermal and hydraulic evolution in various sedimentary basins. It is shown that, in general, the thermal history of sediments is influenced by external processes (sedimentation rates, lithology, climate changes, regional-scale groundwater circulations) which frequently overprint internal processes (variations of crustal/mantle heat flow). It is found that external processes can frequently explain past thermal events that were erroneously attributed to internal causes (tectonic-thermal events). The origin of over-pressures in young basins with high sedimentation rates is shown to be generally related to compaction disequilibrium. Shale permeability values calibrated against overpressure profiles are consistent with experimental constraints. Compaction ...
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region observations. I have approached ...
Qualitative interpretation of data of different nature and sources, based on segmentation techniques such as discriminant analysis, is useful to characterize and monitor hydrocarbon reservoirs. In order to make this interpretation more reliable, it is necessary to characterize uncertainties attached to data and then, to propagate them in the interpretation work-flow. In this thesis, uncertainties are represented by intervals, because usually, little is known about input data errors. The uncertainty characterization issue is dealt with specifically for each case study. The uncertainty propagation issue is treated by a new technique, based on interval analysis, which consists in extending to intervals various popular approaches (non parametric, quadratic and linear) to discriminant analysis: Firstly, a learning phase allows calibrating an imprecise classifying model on the basis of pre-interpreted data. If the quality of this model is good enough, it is used to ...
Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included
The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.
sur la médiatisation des élections Il s'est ouverte le 16 septembre 2011 à Matadi dans le Bas-Congo une formation sur la médiatisation des questions électorales,...
We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).
The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...
The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available
In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...
L'invention concerne un procede de triage de cristaux irradies. Ce procede non destructeur comporte l'irradiation des cristaux par un rayonnement ionisant pendant une duree et avec une intensite telles qu'il se forme des centres colores distinctifs dans les matieres contenant des ions aluminium. Les cristaux colores qui correspondent en teinte et en profondeur de couleur a des teneurs en aluminium en dehors de la teneur desiree peuvent etre separes. On peut isoler ainsi des matieres de quartz, de verre, de silicates exemptes d'aluminium dans un melange, ou bien on peut choisir des fractions de ces matieres, chacune contenant une teneur uniforme en aluminium.
Maintenance energy expenditures were mesured for five rumen bacteria, Selenomonas ruminantium, Butyrivibrio fibrisolvens, Bacteroides ruminicola, Megasphaera elsdenii, and Streptococcus bovis, by using a complex medium with glucose as the carbon source. Large differences (as high as 8.5-fold) in maintenance energy expenditures were seen among these bacteria. The suggestion is made that maintenance requirements could be a significant determinant of bacterial competition in the rumen. Theoretical maximum growth yields, calculated from double reciprocal plots of yield versus dilution rate, were compared to theoretical Y(ATP) values in order to estimate minimum molar adenosine 5'-triphosphate yields from glucose for each bacterium. Results showed that relative yield among the bacteria was growth rate dependent. At high dilution rates, both S. ruminantium and S. bovis produced lactate as their principal fermentation product. At lower dilution rates very little lactate ...
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...
This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...
The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...
Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...
... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for ...
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).
Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...
The UFIP (French Petroleum Industry Association) studies concerning polluted sites and soils and their rehabilitation are presented: characterization of the admissible maximum fuel or gas oil content in the ground, the issue of time effects, and the risks it may induce for public health; study on the various pollutant impacts on the environment (underground waters, biotope...); approach to the development of a dynamical model describing these phenomena and their influence on man, in order to derive consistent and reasonable decontamination objectives
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
This document is the safety analysis made by the national association of the local commissions of information about nuclear activities (ANCLI), about the safety of graphite storage silos of Saint Laurent des Eaux nuclear facility. The analysis covers: the operation safety and the accident hypothesis, the monitoring of indoor and outdoor contamination in routine situation, the geotechnical characteristics of the site environment, the isotopic inventory and the estimation of radioactivity in routine and accidental situation, the estimation of doses received by the population in accidental situation and the internal emergency plan. After examination of these different points, the scientific committee of the ANCLI considers that a new global evaluation of risks, which integrates more recent exposure data, has to be carried out. (J.S.)
The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...
This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...
BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...
The central topic of this work is the study of the properties and the implementation of a Paul trap used for the measurement of the beta-neutrino angular correlation parameter in the decay of {sup 6}He. This coefficient provides a signature of the nature of the interactions involved in the weak interaction. The value of this coefficient can be deduced from the kinematical distribution of the decay events. An electromagnetic trap is used for the trapping of {sup 6}He{sup +} ions in a small volume. This trap has an open geometry that enables the detection in coincidence of the electron and the recoil ion emitted in the beta decay. A dedicated detection set up is used for the measurement of the electron energy, the ion time of flight and the position of the two particles for each event. A general description of the LPCTrap facility and of its performances is presented and shows that this set up is able to fulfill the proposed measurement. Especially, a comparison is made between the ...
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert ...
Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between...Full Text Available
The IWA and ISWA congresses organized in Paris in july showed the latest research developments in the field of water and wastes management. The water sector is more mature than the waste sector but for both a closer association of the public and private is increasing. A summary of the presentations in successively the water and the wastes management is proposed bringing an analysis of the international situation and regulations. (A.L.B.)
This text presents the annotations of all different articles of the law text concerning the sustainable development of radioactive materials and wastes. (A.L.B.)
After a presentation of methods and tools for the basic and extensive characterization of polluted sites and the study of evolution and transfer of current organic pollutants in the ground, the example of the rehabilitation of an old Rhone-Poulenc site (at Chauny, France) polluted with metals and arsenic, is described: soil and aquifer diagnosis, risk analysis and determination of migration schemes
This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
RESUME: Cet article propose une tude du r le croissant que joue l valuation dans la gouvernance des services domicile en Europe. L introduction de quasi march s dans plusieurs pays europ ens va de pair avec un processus d autonomisation de la fonction d valuation qui devient un v ritable outil de r gulation de la concurrence. Une analyse compar e des situations en Belgique, France et Royaume Uni, tant de la demande que de l offre de services, met en vidence les tensions r currentes dans les objectifs de l valuation (qualit des services, ma trise des budgets sociaux, cr ation d emploi), la faible prise en compte de la qualit de l emploi ainsi que les limites des dispositifs standardis s d valuation au regard de la rh torique du libre choix de l usager (consommateur).
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...
The presented paper describes the formulation of the fractional mass balances which are used to calculate the concentration and size distribution of char in the balance cells of a circulating fluidized bed boiler. In case of using the shrinking core model additionally the distribution of conversion of the char particles is calculated. Basically two reaction models (a shrinking particle and a shrinking core model) are available to describe the combustion process. The model considers all essential physico/chemical phenomena (primary fragmentation, attrition, mass transfer to gas phase) which have to be taken into account for the description of the combustion process. The model is part of an overall simulation program for circulating fluidized bed boilers. This engineering simulator has been developed to return the main performance parameters of such systems like temperature along the furnace height, size distribution of balanced solid components, heat flows at the different heat ...
MPA research activities focus on fracture prevention and on the development of a generally applicable method of component integrity testing which, independent of the safety relevance of the components involved, is also part of ageing management. (orig.) [German] Die Forschungsaktivitaeten an der MPA im Hinblick auf die Erhoehung der Sicherheit und Zuverlaessigkeit komplex beanspruchter Bauteile orientieren sich an den Grundgedanken des Basissicherheitskonzepts (Prinzip des Bruchausschlusses). Zielsetzung war dabei die Entwicklung eines allgemein anwendbaren Nachweisverfahrens zur Komponentenintegritaet, das, abhaengig von der sicherheitstechnischen Relevanz der zu betrachtenden Komponenten, auch Bestandteil des Alterungsmanagements ist. (orig.)
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
The report published in 2003 by the European committee on the risk of irradiation (C.E.R.I.) criticizes a part of the ICRP recommendations relative to the internal contaminations.Consequently, I.R.S.N. wishes to supply its own analysis. The present report points the questions linked to the internal contamination and to the difficulties inherent to the risk incurred after chronic exposure.Consequently it does not treat all the problems of the workers and populations radiation protection. (N.C.)
This issue of Barrages newsletter comprises three articles. The first article treats of the quality approach relative to the organization of the inspections of big and medium size dams. It summarizes the improvements of this approach added in 2003 after analysis of the experience feedback. The second article presents the conclusions of the decennial and annual inspections of dams in exploitation. Only the observations requiring a special follow-up are reported. The last article summarizes the activities of the control services for the third quarter of 2003: decennial and annual visits, important facts, administrative instructions, studies, projects and works, organization of services, technical studies etc.. (J.S.)
French ... Orig. Title Scintigraphie osseuse quantifiee chez l'enfant et l'adolescent - repartition selon l'age des taux de fixation de diverses pieces osseuses normales.
The authors introduce the above electric car. They deal particularly with the vehicle concept, the energy consumption and the emission balance. (orig.).
French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.
Field campaigns were conducted in 1981 and 1982/83 on the Dutch coast near Egmond. Measurements were made of surface elevations, water velocities and sediment concentrations in 3 to 8 surf zone locations and 2 to 5 offshore locations simultaneously. A des...
Neonatal exposure to diethylstilbestrol (DES) can alter the structure of the testicular excurrent ducts in rats. We characterized these changes according to dose and time posttreatment and established...Full Text Available
ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available
Coasts are exposed to chronic or accidental pollutions by hydrocarbons. The aim of this study is to show the importance of the microbial layers (stratified sedimentary systems) in the biodegradation of the hydrocarbons. (A.L.B.)
Some crops of important nutritive requirements have been collected from farmlands located in Bitsichi an old tin mining town in north central region of Nigeria. The food crops were analyzed in order to determine trace element concentrations level using Neutron Activation Analysis (NAA). The activity concentrations due to natural radionuclides in the food samples and soil samples collected within the root zone of the crops were also determined using gamma-ray spectrometry (GRS). The NAA results obtained showed higher concentration of Potassium among the essential elements in all the crops. Calcium concentration in both maize and Guinea corn was below detection limit and also Zn in Green beans, sweet potato and cassava. The trace elements; Sc, Hf, Sm, and Th, were below detection limit in all the crops except in Green beans. Rubidium (Rb) and lanthanum (La) were below detection limits only in Cabbage. The activity concentrations of the natural radionuclides in the food samples were found ...
Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...
This work gives a global view of legislations in which are included metals chemical states, briefly recalls the conditions to be respected for the CRM (Certified Reference Materials), and describes the results of some current plans for the Norms, Measures and Tests program. (O.M.) 23 refs.
This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels
Two of the working sessions of the meeting were devoted to aspects of international atomic energy law; the international character of the meeting was also reflected by the home countries of the members of the panel discussion concluding the working sessions. There was substantial reason to put emphasis on the international dimension of the topics discussed. In June 1994, the Nuclear Safety Convention had been signed in Vienna by diplomatic representatives of the signatory countries, and this Convention marks a signpost in the history of international atomic energy law. At the time the meeting was held, negotiations for improving the international nuclear lability law, which had been dragging on since 1989, had come to a stalemate. The meeting offered a suitable forum for taking a scientific approach to tackle the complex problems involved in reshaping the law on nuclear safety and nuclear liability. The third working session of the meeting has been discussing topics relating to the ...
CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung ...
Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und detailreich darstellen lassen. In der ...
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.
Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...
The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...
Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein ...
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
From autumn this year, the FRJ-2 of the Research Center Juelich will be supplying molybdenum targets to the Institut National des Radioelements in Fleurus, Belgium - which deals in medical radio-isotopes worldwide - thus helping to meet the need for technetium-99, which is used in the medical profession for diagnostic purposes because of its favourable radiological characteristics. Technetium-99 is formed as a result of the radioactive decay of molybdenum-99. For many years now, molybdenum has been produced by the irradiation of uranium in research reactors, so that the initiation of molybdenum production in the FRJ-2 is not especially new. What is unusual, however, are the particular peripheral conditions which result from the combination of the irradiation requirements, a predetermined target design and the technical characteristics of the reactor and which necessitated special solutions. This applies especially to the handling of the targets after irradiation, ...
The objective of the project was to develop an infiltration material based on SiC that should have improved corrosion resistance and should permit higher operating temperatures. From a variety of tested doping agents, zirconium silicide and molybdenum proved to be the most appropriate agents. The respective infiltration materials permit a combination of advantages of the SSiC with those of the SiSiC. Silicide SiC, analogous to the SiSiC, is almost nonshrinking, and above all is more corrosion-resistant than SiSiC in the alkaline regime, due to the replacement of free silicon by silicide phases. The operating temperature of the molybdenum-base variant is 1600 C. (orig./CB) [Deutsch] Ziel des Vorhabens war die Entwicklung eines Infiltrationswerkstoffes auf SiC-Basis mit verbesserter Korrosionsbestaendigkeit und hoeherer Einsatztemperatur. Aus einer Vielzahl von getesteten Dotierungsmoeglichkeiten kristallisierten sich Zirkondisilicid und Molybdaen als geeingete ...
Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische Information unabdingbar: Wenn neurologische Veraenderungen im Bereich ...
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films ...
Abuzakuk T, Coward P, Shenava Y, Kumar VS, Skinner JA. The management of wounds following primary lower limb arthroplasty: a prospective, randomised study comparing hydrofibre and central pad dressings. Pris en charge des plaies apres arthroplastie primaire du member inferieur: une etude randomisee prospective comparant hydrofibre et pansements central pad La prise en charge des plaies apres arthroplastie du member inferieur n'a pas fait l'objet de recherches approfondies, essentiellement car ces plaies cicatrisent habituellement sans complications. Cependant, lorsque des implants prothetiques sont utilizes, les serieux problemes de plaies peuvent devenir desastreux. Nous rapportons les resultants d'une etude prospective, randomisee, controlee comparant un hydrofibre et un pasnement centra...
The contribution outlines the current status of the building construction projects for the German Bundestag in Berlin. The following subjects are discussed: Energetic quality of the building, energy supply concept, integrated energy supply system, electric CHP systems, cogeneration (vegetable oil), aquifer storage (heat storage, cold storage), solar energy (photovoltaic energy conversion, thermal solar energy use), economic and ecological aspects. (HW) [Deutsch] Der vorliegende Beitrag gibt einen Ueberblick ueber den aktuellen Stand des Bauvorhabens des Deutschen Bundestages in Berlin. In diesem Zusammenhang wird auf folgende Themen eingegangen: Energetische Gebaeudequalitaet, Energieversorgungskonzept, Energieverbund, stromgefuehrte BHKWs, Kraft-Waerme-Kopplung (Pflanzenoel), Aquiferspeicher (Waermespeicher, Kaeltespeicher), Sonnenergienutzung (Photovoltaik, thermische Solarenergienutzung), Wirtschaftlichkeit und Oekologie. (HW)
In the first part of the symposium, experts reviewed the state of the art of decentralized waste water treatment in Europe. In the second part, exemplary solutions in Poland and the Czech Republic were presented. The final part was dedicated to future concepts and strategies. [German] Im Herbst letzten Jahres hat die Kommunale Umwelt-AktioN U.A.N. in einer Abfolge von drei Abwasserfachsymposien Expertenrunden zum Austausch ueber den aktuellen Stand des Wissens zum Thema dezentrale Abwasserbehandlung veranstaltet. Mit dem Internationalen Symposium 'Konzepte zur Abwasserbehandlung im laendlichen Raum Europas' in Celle hat das Projekt der U.A.N. seinen Abschluss gefunden. Der Konzeption des Projektes entsprechend haben im 1. Teil des Symposiums Experten ueber den Stand der Entwicklung auf dem Sektor der dezentralen Abwasserbehandlung in Deutschland berichtet. Im 2. Teil unserer Fachtagung wurden europaeische ...
The goal of this project was to develop a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing. For this purpose processes of ion-beam-assisted removal (sputtering), separation, sample handling and ion-beam-assisted chemical etching as well of system-inherent components were examined. As an alternative to a Ga-source a liquid-metal ion source based on a AuGeSi alloy was developed, characterised and used in the FIB 4400. [German] Aufgabe des Projektes war die Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung. Dazu wurden Prozesse der ionenstrahlgestuetzten Abtragung (Sputtern), der Abscheidung, des Probenhandling, des ionenstrahlgestuetzten chemischen Aetzens sowie systemeigener Komponenten untersucht. Als Alternative zur Ga-Quelle wurde eine ...
The first working meeting of the SAPIERR project about regional final storage of radioactive waste in the European Union was held in Piestany, Slovak Republic, on February 19 and 20, 2004. SAPIERR stands for Support Action: Pilot Initiative for European Regional Repositories. This is an independent study supported financially by the European Union within the 6th Research Framework Program. The background to the project is the debate about the feasibility of regional repositories for radioactive waste in the European Union, which has come up again especially with a view to the new accession countries and the draft of a waste management directive within the framework of the Nuclear Package. The results of the SAPIERR Project will be presented in Brussels at a concluding international seminar, most probably in October 2005. The seminar will be open not only to the participating countries but also to other interested European and non-European states. (orig.) [German] Am 19. und 20. Februar ...
On account of a raised appearing of plastic waste and shreddered light fraction (SLF) from old car utilization as well as legal handicaps experiments were carried out at the Institute of Ferrous Metallurgy (RWTH Aachen) on a laboratory rig to inject DSD (Duales System Deutschland)-plastic waste and SLF with the destination of a subsequent raw material utilization in the blast furnace and cupola furnace. The experiments on the laboratory rig with DSD plastics could verify that by injection of specific coal/plastic mixtures into the blast furnace the injection rate could be raised by an improvement in the conversion degree and therefore the amount of the inserted reducing agent can be lowered. The injection of SLF without reduction of the inert materials and of the contents on alloying elements and/or tramp elements by extensive preparation has no advantages according to the experiments for the blast furnace process. Pilot experiments on the cupola furnace showed that, assuming a certain ...
The situation of natural gas in the Federal Republic of Germany is described, with particular emphasis on the advantages and consequences of natural gas supply. The brochure discusses the role of natural gas on the energy market, the reliability of natural gas supply, the environmental impacts, the energy-saving effect of natural gas, natural gas prices, the competitive strength of the German gas industry, and the long-term reliability of natural gas supply. (orig.) [German] Die Situation des Erdgases in der Bundesrepublik Deutschland wird beschrieben, wobei die wichtigsten Vorteile und Auswirkungen der Erdgasversorgung besonders hervorgehoben werden. Es geht um die Stellung des Erdgases im Energiemarkt, die Sicherheit der Energieversorgung, Umweltschutz, Energieeinsparung durch Erdgaseinsatz, Erdgaspreise, Leistungsfaehigkeit der deutschen Gaswirtschaft und um die langfristig gesicherte Erdgasversorgung. (orig.)
High energy physics is a basic research domain with a well established European and international cooperation. Cooperation can be of different type depending on the size of the facilities involved (accelerators), on their financing, and on the type of experiments that use these facilities. The CERN, the European center for nuclear research, created in October 1954, is the best example of such a cooperation. This article examines first the juridical and scientifical structure of the CERN and the mode of organization of big experiments. Then, it presents the role of international committees in the establishment of a common scientific policy in Europe and in the rest of the world. Finally, the possible future evolution of the CERN towards a worldwide project is evoked. (J.S.)
Sur l'origine des chiffres arabes A. Boucenna 1 From the pagination of an Algerian Arabic manuscript of the beginning of the 19th century,we rediscover the original shape that the Arabic numerals had before passing in Europe and underwent the transformation that gave the modern Arabic numerals. This original shape,whose use disappeared completely, proves that these numerals have their origin in the Arabic letters. Contrary to what some hypotheses pretend, particularly those that present them as drifting of Indian characters, the 10 Arabic numerals that we use are, nothing else, 10 Arabic letters more or less modified and taken in the "Abjadi" order. The hypothesis of the Indian origin of the Arabic numerals is revealed a mistake denied by the shape of the Arabic numerals and by the logic of the right to left representation of the numbers and the algorithm of the elementary operations. The Arabic numerals that simplified the writing of the numbers and the algorithms ...
In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden Definitionen von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)
In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)
Apart from condensing the off-air condensers have a number of additional functions, which have been added more or less incidentally as development progressed. Advanced development of certain types of turbine condensers justifies the hope that these additional functions can be improved as power plants become cheaper and simpler.(orig.) [German] Kondensatoren haben neben ihrer Hauptaufgabe, der Kondensation des Turbinenabdampfes eine Reihe zusaetzlicher Funktionen, die sich z.T. im Laufe der Entwicklung eher beilaeufig ergeben haben. Der hohe Entwicklungsstand bei bestimmten Bauarten von Turbinenkondensatoren laesst die Erwartung zu, dass im Zuge der Vereinfachung und Verbilligung von Kraftwerksanlagen 'Nebenfunktionen' verbessert werden koennen. (orig.)
The paper describes the latest developments in STRASSY (Strategy Assistance System), the strategy assistance system for the inspection of nuclear materials. The user can now select the fuel cycle he wishes to investigate from an initial range of 19 facilities. An inspection interface has been developed to enable the details and dates of inspections to be modified. One of the special features of the application of STRASSY in international safeguards is the taking into account of timeliness of detection; certain aspects of the time manager algorithms are presented and analysed, including the guaranteed existence of a solution. The results of a study of diversion paths in a simplified cycle consisting of our facilities are presented. Finally, the modifications necessary to enable STRASSY to be used for a posterior analysis of inspection results are discussed. (authors). 7 refs., 3 figs.
Utilisation of geothermal energy may soon become an important factor in power supply in Germany. The contribution discusses the utilisation of hydrothermal low-pressure systems, the geological boundary conditions, the technical design of the thermal water cycle, and the current status of the hot dry rock technology. [German] Die Nutzung der Energie ausd Erdwaerme kann in naher Zukunft eine wichtige Rolle in der Energieversorgung Deutschlands spielen. Der vorliegende Artikel gibt einen Ueberblick ueber die Nutzung hydrothermaler Niederdrucksysteme, die geologischen Rahmenbedingungen, den technischen Aufbau des Thermalwasserkreislaufes sowie zum aktuellen Stand des Hot Dry Rock Verfahrens.
This evaluation has for object to inform about the levels in carbon 14 in the environment of the factories of La Hague. Two sectors were differentiated on one hand the terrestrial environment, and on the other hand the marine environment. The investigations concerned first and foremost food products stemming as the vegetable culture (vegetables) or individual breeding (milk, eggs) but also foodstuffs stemming from the local agriculture (cereal). In touch with the second sector, the marine environment, the sampling concerned the accessible products of the sea by all and those locally marketed (fishes, molluscs, shellfishes). The different results are presented in tables. (N.C.)
The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)
The aim of this work is the study of the heat transfer and of thermal behaviour of the HF (high frequency) components (in fact capacitors) of the ITER-proto-2005-FCI antenna. Preliminary results carried out with the Castem software show that it is possible to cool the hottest part of the antenna efficiently. A water flow (1 bar, 25 Celsius degrees) or an helium flow (10 bars, 50 Celsius degrees) permit to limit the maximal value of the temperature to 270 Celsius degrees. A second software Ansys has allowed the author to simulate capacitors with more complicated shapes. (A.C.)
Fur die Trennung binarer Gemische wird zunehmend das Simulated Moving Bed (SMB)-Verfahren verwendet. Fur einen storungsfreien Betrieb mussen die Volumenstrome sowie die Umschaltzeit exakt eingestellt werden. In diesem Beitrag wird mit Hilfe des Coherence-Konzepts eine Methode aufgezeigt, mit der sich die Stellgroen fur einen dispersionsfreien SMB-Prozess bestimmen lassen. Fur Langmuir- und Anti-Langmuir-Isotherme konnen einfache explizite Gleichungen bei vollstandiger Trennung angegeben werden. Das Grundprinzip dieser Methode lasst sich auch auf andere Isotherme sowie fur die unvollstandige Trennung ubertragen.
Japanese companies have developed suitable cleansing technologies and export their know-how. Some original technologies are developed today, like: in-situ chemical oxidation, iron confinement, hot-soil process, low-temperature catalytic decomposition or dechlorination of dioxins. However, some pollutions are still poorly considered (nitrates) or badly mastered (dioxins). This situation is partly due to late legal decisions and to limited pollution abatement measures. Japan is also very active in bio-cleansing research, and this, despite the lack of dialogue and directives at the national level. Several research programs with important funds have started since 1995. However, Japan is still at the preliminary stage in open-field applications of cleansing methods. (J.S.)
Trapezblechstege im Bruckenbau kommen trotz der groen Vorteile, die diese Bauweise bietet, in Deutschland bisher nur an einem Pilotprojekt zur Anwendung. Durch die charakteristischen Eigenschaften des Trapezbleches entstehen konstruktive und wirtschaftliche Vorteile gegenuber herkommlichen Bruckenbauweisen. Allerdings lassen die aktuell gultigen Regelwerke aufgrund fehlender Kenntnis zum Tragverhalten und mangelnder Erfahrung keine wirtschaftliche Ausbildung zu. Dies zeigt sich am Beispiel des Pilotprojekts. Die Ausbildung der Verbundfuge wurde hier nur sehr unbefriedigend gelost und verdeutlicht somit die Notwendigkeit einfacher und praktikabler Verbindungsmoglichkeiten. Am Institut fur Leichtbau Entwerfen und Konstruieren der Universitat Stuttgart wurde in Zusammenarbeit mit dem Institut...
This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...
A whole sequence of the parameters of the combined heat and power system (KWK) is described which enables a comparison between the electricity and heat demand of a consumer and the energy availability through a combined heat and power system. Proceeding from this, a thermodynamic model of a steam and gas process with combined heat and power is introduced which is based on an exergetic balancing of the subsystems of the process. In this way, the varying thermodynamic quality of the energy flows occuring in the process will be taken into consideration so that the results of the model correspond in any case with the second law of thermodynamics. (orig.) [Deutsch] Es wird ein vollstaendiger Satz von Kenngroessen der Kraft-Waerme-Kopplung (KWK) beschrieben, mit dessen Hilfe der Strom- und Waermebedarf eines Verbrauchers mit der Energiebereitstellung durch eine KWK-Anlage verglichen werden kann. Darauf aufbauend wird ein thermodynamisches Modell des GuD-Prozesses mit ...
'Within 15 years the energy consumption bottleneck has shifted from the supply side to emissions, i.e. to the waste side.' Reflecting this statement one may realize the importance of lending more weight to energy conservation but may also be induced to critically analyze the corresponding measures. First results of such reflections are given with regard to the payback periods of air pollution abatement measures relative to the additional emissions they cause. (orig.).
The design changes of the improved 2,5 l direct injection Diesel engine with the nominal power output of 52 kW and a maximum torque of 143 Nm are described. This engine which is installed in the Ford Transit meets all relevant exhaust emission standards that are presently in effect. (orig.).
This publication of the Areva Group, a world nuclear industry leader, provides information on the energy in many domains. This issue deals with the nuclear fuel cycle, the biofuels, the everyday geothermal power, the Unites States energy supply and types, the Bertrand Picard solar aircraft, the kyoto protocol and the wind power leaders. A special chapter is devoted to the renaissance of solar homes. (A.L.B.)
The petroleum and petroleum products increase offer a real development opportunity to the alternative fuels. In the context of the french energy accounting increase, the energy independence notion incites the government to promote these new fuels. If the LPG seems declining because of the accident risks fear, the fuel cell is not for today. Near these two sectors what is the future of the biofuels and the natural gas vehicle or the electric cars? (A.L.B.)
Background and ObjectivesClopidogrel resistance or low-responsiveness may be associated with recurrent atherothrombotic events after drug-eluting stent (DES) implantation. We prospectively...Full Text Available
The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality
This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)
... Producers and their Impacts on Women in Central Java, IndonesiaActions basées sur des scénarios visant à élever ... impact sur les femmes dans le centre de Java, en IndonésieInvestigación-acción basada en...
This study was aimed to test and select hydrophobic activated charcoal, manufactured in Romania, used as adsorbents of solvents which partly compose diluters employed in car industry. With regard to the diluters, three of the seven types of activated charcoal studied (Sorbent 1, R - Cafs and AD3) showed the greatest capacity of adsorption, when determined under dynamic and static conditions. (authors) 8 refs.
This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)
An important opportunity for solving future traffic problems lies in a change of the connection existing between traffic growth and economic development. It could help bring about a cut in traffic intensity. This can be achieved by rationalizing transport processes, i.e. by enhancing the efficiency of traffic via improved organization and infrastructure. Rationalization means that a given traffic effort (distance in kilometres, time, route, energy) can yield a higher transport effect, or a certain transport effect can be attained with less traffic effort. Enhanced productivity permits more transport without more traffic-related and environmental nuisances. (orig.) [Deutsch] Ein wichtiger Weg zur Loesung der kuenftigen Verkehrsprobleme liegt in der Veraenderung des Zusammenhangs der zwischen Verkehrswachstum und Wirtschaftsentwicklung besteht. Damit koennte eine Senkung der Transportintensitaet erreicht werden. Ein Ansatz hierzu bietet die Rationalisierung der ...
The work of the study group for coal conversion by hydrogenation (G.E.C.H.) is an example of well concerted association between research laboratories (CNRS, Ecole des Mines...) and directly interested industrial research centers, (CERCHAR, G d F, IFP). This paper presents the activities of G.E.C.H. in the field of coal conversion by hydroliquefaction.
The position paper will provide the basis for further strategies on offshore wind power development in consideration of ecological and conservation aspects. [German] Das Positionspapier des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit (BMU) einschliesslich des Umweltbundesamtes (UBA) und des Bundesamtes fuer Naturschutz (BfN) ist Ergebnis der Arbeiten der BMU-Projektgruppe 'Windenergienutzung im Offshore-Bereich im Hinblick auf die BMU-Anliegen'. Es beschreibt den derzeitigen Stand einer Strategie zur umwelt- und naturvertraeglichen Erschliessung der Windenergienutzung auf See (Offshore). Es bildet die Grundlage fuer die Weiterentwicklung dieser Strategie und dabei insbesondere zur Abstimmung mit den Anliegen anderer Bundesressorts und den Kuestenlaendern, sowie zur intensiveren Einbeziehung beteiligter Verbaende und Fachkreise. Vor dem Hintergrund der zur Genehmigung eingereichten ...
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
French ... Title Synthese d'agregats metalliques par radiolyse de solutions aqueuses de sels simples ou complexes. Etude par M. E. du greffage des agregats sur membranes de carbone.
Zusammenfassung Der vom Bundesamt f?r Sicherheit in der Informationstechnik (BSI) entwickelte Ansatz des IT-Grundschutzes war bereits Gegenstand von Beitr?gen in der DuD. Inzwischen hat das ?Grundschutzhandbuch? Eingang in die internationale Standard-Familie ISO 2700x gefunden. Der Autor berichtet ?ber die Erfahrungen mit den ersten durchgef?hrten Zertifizierungen nach dem neuen ISO-Standard auf der Basis von IT-Grundschutz.
Some 43 papers were presented in 4 sections: Organ and bud culture of tree species (24 papers); Cell suspension and callus culture of tree species (11); Culture of haploid tissue of tree species and production of wood homozygotes (3); and Isolation, culture and somatic fusion of protoplasts as a means of somatic hybridization and genetic engineering (5).
The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, and building location and planning.
Climate change is not only dangerous but also expensive. On the other hand, air pollution abatement measures are costly as well. Scientists of the Microeconomics Department investigated how air pollution abatement and cost efficiency can best be combined. (orig.)
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
The results of the creep performance studies at temperatures from 700-1000 C with welds of alloy 800 HT, the manual shielded metal arc welds made with Githerm 85 and Grini 209 filler metals, as well as the MIG pulsed arc welds made with the Nicrofer S 206 and Nicrofer S 5520 filler metals, proved to be in very good agreement with the calculated characteristic values published on VdTUeV sheet 434 in comparative assessments based on creep values valid for a service period of 10 000 hours. The MIG pulsed arc weld made with the Nicrofer S 5520 filler metal achieved by far the best results and strength values comparable to those of the base material, whereas the values of the other welds were corresponding to calculated strength values of the base material reduced by 20%. (orig./CB) [Deutsch] Die im Temperaturbereich von 700-1000 C an Alloy 800 HT und den Elektrodenhandschweissverbindungen mit den Schweisszusaetzen Gritherm 85 und Grini 209, sowie den MIG-Pulsed-Arc-Schweissungen mit den ...
The author cites the example of Gelsenkirchen in order to illustrate the measures taken in the field of power supply with regard to air pollution abatement. (orig.) [Deutsch] Der Verfasser gibt am Beispiel der Stadt Gelsenkirchen einen Ueberblick darueber, was hinsichtlich des Klimaschutzes - und zwar bezogen auf die Energieversorgung - in den letzten Jahren in Gelsenkirchen getan wurde. (orig.)
Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0
The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...
Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...
Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.
Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...
Austenitic stainless steel (18% Cr, 12% Ni, Mo gradation between 0,06 to 3,6%) had been solution nitrided. By step-by-step removing, the samples could be prepared with various surface contents of nitrogen from 0.04 to 0.42%. In two test series the influence of nitrogen had been determined. The susceptibility against pitting corrosion of these samples had been tested by the chronopotentiostatical method. For the investigated steel composition and the used corrosion system there is no influence of molybdenum on the effectiveness of nitrogen. The effectiveness of nitrogen can be described by the factor 25 in the PRE. By the investigation of the surfaces with the XPS analysis, it could be shown that the passivation and the pit nucleation is influenced by nitrogen. In these ranges NO{sub x}, NH{sub x}, and NH{sub z}-spectra have been detected. Bound Mo was found in steels containing molybdenum. It is assumed that the repassivation mechanisms of N and Mo work independently of each other. ...
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...
Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.
In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.
The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...
This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. Finally T1-weighted spinecho sequences in high ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects ...
The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row ...
This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free chlorine are discussed. Several possible adaptations of the existing space heating, domestic water heating and ...
The Ministere des Ressources naturelles du Quebec (Quebec Natural Resources Department) implemented a remedial program to treat the waste rock pile at Wood Cadillac, located near Cadillac, in Abitibi, Quebec. The solutions proposed by INRS-Georessources and ENVIROCONSEIL are aimed at eliminating erosion and stabilizing the geochemical processes. Part of the proposed solution also included the use of a reducing trickling filter for the treatment of acid leachates, which also contain arsenic when exiting the waste rock pile. The trickling filter is composed of forest tailings in which the bacteria reduce the sulphates and stimulate the precipitation of arsenic into arsenic sulphates. This is a new treatment that was developed following laboratory experiments which demonstrated the feasibility of the process and quantified the parameters. A demonstration unit was constructed by ENVIROCONSEIL and installed at the Wood Cadillac waste rock pile under the supervision of ...
The project is intended to yield information on the transfer factors describing the transfer of ingested radionuclides to breast milk for the following elements: antimony, cerium, chromium, cobalt, gallium, lanthanum, molybdenum, niobium, radium, ruthenium, silver, thorium, titanium, and uranium. Those yet unknown or poorly known transfer factors are required in order to be able to develop a reliable model for description and assessment of the transfer of the radionuclides and the possibly resulting hazardous doses to infants, and for subsequent formulation of recommendations for radiological protection of the population. (orig./CB) [German] Ziel des Projektes ist die Ermittlung von Transferfaktoren fuer den Uebergang von Radionukliden aus der Nahrung der Muetter in die Muttermilch fuer die Elemente Antimon, Cer, Chrom, Cobalt, Gallium, Lanthan, Molybdaen, Niob, Radium, Ruthenium, Silber, Thorium, Titan und Uran. Um die Exposition und damit die moegliche Gefaehrung ...
R?sum? La rate baladeuse est une anomalie rare chez l?enfant. Elle est souvent d?crite chez l?adulte, particuli?rement la femme enceinte. Elle est due ? un d?faut de fixit? anatomique de la rate avec les organes de voisinage. Ses manifestations cliniques sont variables, mais la complication la plus redoutable est la survenue d?une torsion du p?dicule spl?nique. Nous rapportons le cas d?une fille de 11 ans qui s?est pr?sent?e avec des douleurs abdominales aigu?s et des vomissements. Les examens radiologiques ont montr? une absence de la vascularisation spl?nique. ? l?exploration chirurgicale, on a d?couvert une torsion du p?dicule spl?nique avec une isch?mie tissulaire avanc?e. La rate ?tait d?pourvue d?attaches ligamentaires. La d?torsion n?a pas permis de sauvegarder la rate, et une spl?n...
The sedimentary geometry is determined by several types of stratigraphic surfaces: transgressive surfaces (TS), maximum flooding surfaces (MFS) and downward shift surfaces (DS). They are organized hierarchically into major and minor surfaces from the facies stacking-pattern. These surfaces which are observable on well logs and cores structure the sedimentary architecture and are, therefore, the best candidates to form major seismic reflectors. The well (logs and cores) to seismic (surface seismic) passage involves inherently a change of observation scale. That is from a high resolution sequence stratigraphy (metric to pluri-metric) to a sequence stratigraphy s.l. (decametric to pluri-decametric). This passage is composed of two phases. The first phase consists of the validation of density and sonic logs whose product corresponds to the acoustic impedance. The second phase allows for the modelling of the geological cross section of a field in a synthetic seismic section which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The need of conventional ...
For the laying of natural gas transport pipelines severe soil protection guidelines are in force in Switzerland. These guidelines influence, above all, the course of the construction in a substantial way. The Federal Office of Energy promulgated these guidelines in May 1993. They have provisional character and shall be reviewed based on the experiences with the in 1994 executed pipeline constructions. The protection of the soil from mechanical-physical loads, specially from soil erosion and compaction, is also a part of the modification of the federal legislation concerning environmental protection which is being dealt with at present by the federal parliament. (orig.) [Deutsch] Fuer die Verlegung von Erdgas-Transportleitungen gelten in der Schweiz strenge Bodenschutzrichtlinien, die vor allem den Bauablauf nachhaltig beeinflussen. Die Richtlinien wurden im Mai 1993 durch das Bundesamt fuer Energiewirtschaft erlassen. Sie haben provisorischen Charkater und sollen aufgrund der ...
On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am 21. Juli 1998 ...
Passive films, formed on annealed and cold worked AISI 304 stainless steel in hot chloride media, were examined using polarization resistance and impedance measurements. The obtained results show the influence of cold work on film conductivity, which can be correlated to conditions of susceptibility to stress corrosion cracking. Capacitance measurements, using the Mott-Schottky approach, revealed that a change from n to p type semi-conductivity is associated to susceptible conditions with an increase in the doping density estimated for cold worked samples in the presence of chloride. It is assumed that p-type semi-conductivity of the passive film together with the position of the flat band potential has a strong influence on the dissolution processes at the corrosion potential. Based on this analysis the influence of plastic deformation, at the dislocation scale, is discussed. (authors)
Proactive qualification is today an integral part of the development process for steam turbines used in steam and combined cycle power plants. By providing experimentally based `random` variables, such as the steam path efficiency and blading reliability, it makes a valuable contribution to the economic `random` variables of the power plant, e.g. the rate of return, as viewed by the customer. One of the areas in which proactive product and process qualification plays an important role is the development of LP steam paths. (orig.) [Deutsch] Die proaktive Qualifikation ist heute fester Bestandteil des Entwicklungsprozesses bei Dampfturbinen, die fuer den Einsatz in Dampf- und Kombikraftwerken bestimmt sind. Sie leistet mit Hilfe experimentell ermittelter `Zufalls`-Variablen, wie z.B. Wirkungsgrad der Fluten und Zuverlaessigkeit der Beschaufelungen, einen wertvollen Beitrag zu den fuer die Kunden wichtigen wirtschaftlichen `Zufalls`-Variablen des ...
Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)
LP steam turbine retrofits are generally undertaken as a result of mechanical problems, for example due to stress corrosion cracking, torsional vibration or erosion. They present plant operators with an opportunity to introduce advanced aerodynamic technology, and at the same time improve efficiency and availability. Standard components, the majority proven in long-term service, can be used to obtain a permanent solution to the problems. In several European countries, retrofits have been carried out on intact LP steam turbines owned by utilities whose primary motivation is efficiency improvement. (orig.) [Deutsch] Niederdruck-Dampfturbinen werden in der Regel nur dann nachgeruestet, wenn waehrend des Betriebes Probleme durch Spannungsrisskorrosion, Torsionsschwingungen oder Erosion auftreten. In solchen Faellen bietet sich die Gelegenheit, eine moderne aerodynamische Loesung zu waehlen, die gleichzeitig Wirkungsgrad und Verfuegbarkeit verbessert. Es wird gezeigt, ...
For the inventory of water tritium concentration in the Manche department, it is the complementarity that animated the work opened during year 2001. To answer to a commune sensitivity such water quality, particularly drinking water at tap, the A.C.R.O. laboratory brought its know how to make and its technical means in the area of tritium analysis and the general council brought its know how to make and its logistics means in matter of sanitary control. This collaboration has allowed to supply an indication on the tritium content of the distribution waters of thirty of the most important cities of the department. Then, it allowed to inform on the radiological situation (in relation with the tritium presence) of coast waters and principal rivers waters. More than 160 controls have been realised between the months of march 2001 and february 2002. Only the tritium under the shape of tritiated water has been measured. The measures have been made by liquid scintillation according to the ...
In this paper, we present the work carried out within the framework of the FEVER project (Fuel cell Electric Vehicle for Efficiency and Range), an European project coordinated by Renault, joining Ecole des Mines de Paris, Ansaldo, De Nora, Air Liquide and Volvo. For the FEVER project, where an electrical air compressor is used for oxidant supply, there is no need for hydrogen spill over, meaning that the hydrogen stoichiometry has to be as close to one as possible. To determine the optimum hydrogen utilization efficiency for a 10 kW Proton Exchange Membrane Fuel Cell (PEMFC) fed with pure hydrogen, a 4 kW prototype fuel cell was tested with and without a hydrogen recirculator at the test facility of Ecole des Mines de Paris. Nitrogen cross over from the cathodic compartment to the anodic compartment limits the hydrogen utilization of the fuel cell without recirculator to 97.4 % whereas 100% is feasible when a recirculator is used. 5 refs.
The second volume contains a comprehensive presentation of inflammatory bone diseases, including seldom primary chronic osteomyelitis and morbus Paget. Substantial chapters on bone tumors and tumor-like lesions of bone joints are covering the state-of-the-art of diagnostic techniques of these seldom but important diseases. Besides the importance of projection radiography the contribution of MRI within differential diagnosis und staging of these diseases is emphasized. [German] Der zweite Band des Muskuloskelettalen Systems befasst sich mit der umfassenden Darstellung zur Diagnostik entzuendlicher Knochenerkrankungen und beinhaltet neben den klassischen infektioesen auch die seltenen, primaer chronischen Osteomyelitiden und den Morbus Paget. Umfangreiche Kapitel ueber die Knochentumoren und tumoraehnlichen Laesionen der Gelenke stellen in modernster Weise den aktuellen Stand des Wissens und der Diagnostik dieser seltenen, aber aus ...
In the course of the research project 'Investigations of trace element concentrations in coal seams with different mineral groups', 31 seam coals of the Ruhr Carboniferous were analysed in order to determine the bending of 14 coal-relevant trace elements to the mineral groups and/or minerals of the coals. Products with different ash content were produced by fluctuation of the seam coals in a laboratory cell. The raw coals and fluctuation component products were analyzed chemically and mineralogically in order to get a quantitative raw material characterisation of the sampled material. Particular interest is taken in the chemical and non-ecological composition of the mineral as ash carrier in the coal and the fluctuation component products, as well as in trace element control. (orig./EF).
The examples quoted show that damage is mostly due to faults of design and construction or faulty operation. The ever shorter development cycles, the further development of existing constructions and cost pressure owing to price slumps are very important in this context. Careful endoscopic inspections and monitoring and early identification of beginning damage helps to prevent major damage and follow-up damage. The causes of changing operational performance must be established as early as possible to prevent larger damages from being caused by continued operations.(orig.) [German] Die vorgestellten Schadenbeispiele zeigen, dass die Schaeden vorwiegend durch Auslegungsfehler und Konstruktionsfehler aber auch durch Bedienungsfehler verursacht wurden. Die immer kuerzeren Entwicklungszeiten fuer Neukonstruktionen und die Weiterentwicklung vorhandener Konstruktionen sowie der Kostendruck infolge des Preisverfalles sind hierbei von grosser Bedeutung. Weitherhin ist die ...
Freezing and thaw have an effect on soils, and the effect of the freeze-thaw cycle on soil covers used in the control of acid mine drainage was discussed in this poster presentation. The purpose of soil covers in cases involving acid mine drainage (AMD) is to reduce the exposure of tailings to oxygen which cause AMD. The effect of this freezing-thaw cycle on soft materials used in soil covers with capillary effect was studied. Some laboratory experiments were conducted to evaluate the properties of the moisture retention layer. The preliminary results were presented. The results indicated that the freeze-thaw cycle might affect the performance of soil covers in the long term, depending on the type of materials selected. Further research is undergoing. 26 figs.
Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
Developments in the past 10 -15 years in the fiels of `steel`, `boilers`, `steam turbines` and `environmental protection` show that the advanced coal dust furnace technology is another option of clean coal technology. The contribution discusses some of the current problems facing the main partners of the coal sector, e.g. coal producers, public utilities and suppliers of steel, boilers and turbines. (orig./GL) [Deutsch] Die Entwicklung der vergangenen 10-15 Jahre in den Bereichen `Stahl`, `Kessel`, `Dampfturbinen` und `umweltschutztechnische Anlagen` verdeutlicht, dass die fortgeschrittene Kohlestaubfeuerungstechnologie ebenfalls eine Option der `Clean Coal Technologies` ist. Im Rahmen dieses kurzen Aufsatzes wird nun versucht, einige zeitgemaesse Problemkreise der Hauptakteure des Strommarktes, wie z.B. des Kohlefoerderers, der Stromproduzenten und der Stahl-, Kessel- sowie Turbinenhersteller anzudeuten. (orig./GL)
The analyses were carried out using real climate data for the years 1987 and 1989. The course of the indoor climate for year-round free ventilation with a constant flow volume is discussed. Numerous diagrams inform on ambient temperature, water vapour content, the condition of space air, and temperature drops below dew point. For the event of heating of the central part of the church, space air condition, the annual air humidification requirement, and the temperature field in this part of the building are described. (MSK) [Deutsch] Die Untersuchungen wurden mit aktuellen Klimadaten fuer die Jahre 1987 und 1989 durchgefuehrt. Der Verlauf des Raumklimas bei ganzjaehrig freier Klimatisierung mit konstantem Foerderstrom wird erlaeutert. Dabei wird die Raumlufttemperatur, der Wasserdampfgehalt, der Raumluftzustand sowie die Taupunktunterschreitung in zahlreichen Diagrammen aufgezeigt. Weiter werden fuer den Fall der Beheizung des Hauptraums der ...
The wastes management policy takes into account more and more often the environmental impacts mastership. This evolution is particularly appreciable when the wastes directly interact with the environment: storage, utilization for roads construction and so on. In this context the ADEME organized the 8 june 2000 a colloquium to present the new evaluation methods and tools, to describe the regulations and to identify the research programs needed for this environmental policy. Eleven papers are presented. (A.L.B.)
Although the oil price is still far from its historical maximum, the oil market is today in crisis. To explain this situation the author discusses the nature of the supply constraints. The reserves are today better known and so more plentiful than at a previous period of the oil history and the russian production since 2004 is stagnating. The main factor seems to be the OPEC policy and in particular the will of limiting the oil production to defend upper prices. (A.L.B.)
The European Court of Justice has defined a clear means by which waste utilisation methods can be distinguished from waste disposal methods in a logical, well-understandable manner. With its stringent definition of ''utilisation'' this judgement points the way to quality-oriented waste management practices. We do not share the often voiced fear that this decision will lead to an increased incineration of compound wastes in industrial plants such as cement works. From the fact that, according to the decision by the European Court of Justice, wastes destined for utilisation fulfil a certain purpose and therefore, if not available in sufficient quantity must be replaced by primary raw materials, it follows that these wastes are required to fulfil specific quality criteria. This is rarely the case, if at all, with compound wastes. From the viewpoint of Luxembourg the decision by the European Court of Justice can be regarded as a positive impulse towards ...
The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)
The French office for technical studies and control of big dams (BETCGB), has recently reedited the `guidebook for the control of dams in exploitation`. The aim of this document is to provide to the regional directions of industry, research and environment (DRIRE) a methodological help for their control actions of hydroelectric dams granted for exploitation. It comprises 6 chapters dealing with: the different type of dams, the inspection, the surveillance, the floods evacuation, the flood instructions, and the particular emergency plans. (J.S.)
This report is published in the framework of the 1991 French law for the nuclear waste management. The state of the art reported here concerns the long term evolution of spent fuel in the various environmental conditions corresponding to dry storage and geological disposal: closed system, air and water saturated medium. This review is based on the results of the french PRECCI project (Research Program on Long term Evolution of Spent Nuclear Fuel) and on literature data. (authors)
The study required by the West German Ministry of Research and Technology (RS 605) for the Committee on 'Future Nuclear Energy Policy' of the 9th German Parliament is concerned with the following main points: 1) Assessment of technical risks from the social aspect; 2) Discussion of terms and quantification of risks; 3) 'Engineering judgment' and 'questionable' methods in the Fast Breeder analysis of the Society for Reactor Safety (GRS); 4) Assessment criteria of potential damage.
The work opened by the A.C.R.O. is in line with in an initiative of evaluation of the radiological quality of marine and continental waters of the Normandy coast. In this perspective, measures of radioactivity were made, not near an emissary (already very watched environment) but in more large scale because in marine environment, more than 640 km of coast are concerned. It was a question of supplying a representative assessment of the radioecological situation, for one year,of the marine environment (along the Normandy coast) and main streams which supplies it. (N.C.)
Court decisions available so far do not primarily consider the problems linked to the commissioning of an expert and his mandate, as well as the legal status of the commissioning of an expert as an administrative act which might be legally contestable. Thus there are at present no court decisions that would create legal certainty in matters of the act of commissioning a nuclear expert opinion. The current legal situation is such that an independent order for commissioning of an expert opinion in compliance with section 19 III AtG (Atomic Energy Act), which in general is given in response to the refusal of the facility operator to do so, can be independently contested on the basis of section 44 a, sentence 2 VwGO (Rules of Administrative Courts). The current practice of conflict-oriented, or nuclear power phase-out-oriented, implementation of the nuclear law poses a threat to our constitutional state and to our democracy. The supply of energy as a common good is of essential importance ...
A major component of the 1990 recommendations of ICRP (ICRP, 1991a) was the revision of the dose limits. But other changes were introduced which necessitated a review of earlier guidance. In particular, ICRP set up a Task Group in 1993 to prepare a report on the principles for the protection of workers. The report was adopted in 1997 and has now been published as ICRP Publication 75 (ICRP, 1997). It is for others to judge the real significance of the guidance provided; what follows are some of the main points. (author)
The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)
This paper presents fundamental researches based on the electronic structure calculations and X absorption spectroscopy, allowing the knowledge on nuclear fuels at an atomic scale. They bring a better understanding of these material behavior to accurate the macroscopic simulation. The calculation methods, the experimental techniques of validation and the ab initio calculations results are detailed. (A.L.B.)
Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [German] Das Staging ...
There is much interest worldwide in low-emission, low-noise electric cars. Modern vehicles with advanced technology are an interesting alternative to conventional cars. (orig.) [Deutsch] Das Interesse an den emissionsfreien und leisen Elektroautos ist weltweit ungebrochen. Die heute verfuegbaren Fahrzeuge zeigen die betraechtlichen, in den letzten Jahren erzielten Fortschritte, die sie fuer immer mehr Anwender zu einer beliebten Alternative zur Benutzung des konventionellen Autos machen. (orig.)
The nuclear structure of A {proportional_to} 100 nuclei has been studied in the frame of this thesis with a recently developed {beta} - {gamma} - {gamma} triple coincidence fast timing technique and different models such as shell model, hydrodynamic model, Nilsson and particle-rotor models. This technique which allows the measurement of the level lifetimes in the ps range has been applied at JOSEF at the research reactor DIDO of KFA Juelich in studes of the short-lived neutron-rich nuclei in the A {approx_equal} 100 region. Lifetimes of level in {sup 96},{sup 98},{sup 100} ZR, {sup 99},{sup 101}-{sup 104} Nb, {sup 100}-{sup 105} Mo have been measured, which are in many cases completely new, and otherwise more precise than previously published data. From the lifetimes of the members of rotational bands, the size of the nuclear deformations has been deduced. (orig./HSI). [Deutsch] Im Rahmen dieser Doktorarbeit wurde die Kernstruktur der A {proportional_to} 100 Kerne untersucht. Dazu ...
The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the results presented in this work it is concluded ...
The report discusses: Combustion characteristics of various commercial cokes for cupola furnace operation; quality level of modern cokes; foundry coke, blast furnace coke, MB coke; characteristic data, e.g. grain size distribution, drum resistance, concentrations of water, carbon, sulphur, ash, and volatiles, reactivity; changes in coke quality during transport. (HS)
An investigation of the solidification behavior was carried out on the directionally solidified single crystal superalloy CMSX 6. The relationship between structure morphology and the process parameters has been experimentally determined and illustrated in a solidification diagram. The metallographic analyses of transverse sections within the solidification interval yield the sequence of phase formation and the evolution of solid fraction. The solidification process and the corresponding structure have been discussed in detail. (orig.)
A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)
Two hypotheses are in the centre of this investigation, on the one hand the question, whether microwaves as exogenous fields alone are able to stimulate human muscle cells above-threshold, and on the other hand, whether microwaves as conditioning to cathodical electrical pulses can modify the excitation threshold and form. No excitation through the application of microwaves alone can be introduced at any subject. The conditioning of above-threshold cathodical electrical pulses with UMTS-microwaves leads not to a transgression of the threshold or the electrical muscle response (EMG) depending on the amplitude, the duration or the dose rate. (orig.)
The in-situ observation of dendritic growth in lithium/polymer electrolyte-LiTFSI/lithium battery cells shows that dendrites grow up with about the same rate as anion migration. Memory effects have been evidenced in cycling experiments and limit the dendrites length. An overall movement of the electrolyte due to variations of electrolyte concentration in the vicinity of the electrodes has been observed too. (J.S.) 13 refs.
In the framework of the carbon storage two forestry methods are analyzed by the author: the standing capitalization (slowing of the crops) and the spices substitution (slow growing species by fast growing species). The construction of a model taking into account the all stage of the carbon implication (biomass, soil, forest products) offers simulation and quantitative results on these methods. (A.L.B.)
Progress reports on the European Research Centre for Air Pollution Control Measures project are presented. Topics covered were: assessment and analysis of the impacts of airborne pollutants on forest trees, and distinction from other potential causes of recent forest dieback; research into atmospheric dispersion, conversion and deposition of airborne pollutants; development and optimization of industrial technical processes to reduce or avoid emissions; and providing instruments and making recommendations to the industrial and political sectors.
High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d`Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d'Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.
In order to improve the capacity and service life of cathodes, the effect of carboxy-methyl cellulose, soot, silica gel and fibres was examined. Structural tests and electrical and electro-chemical measurements are used for this. The additives can affect crystallization in the manufacturing stage of the electrodes and can increase the storage capacity for water and the electronic conductivity. They act to stabilize the mass in cyclic operation. Soot additive has little effect on the properties of the electrode, but the other substances increase the service life or the use of the mass. (LU).
CYRANO3 is the new EDF thermomechanical code developed to evaluate the overall fuel rod behavior under irradiation. In that context, this paper presents the phenomena to be simulated and the correlations adopted for modelling purposes. The empirical models presented are taken from the CYRANO2 code and a compilation of the relevant literature. The present revision corrects and supplements version B on the basis of its use during the software coding phase from January 1991 to May 1993. (authors). figs., tabs., 120 refs.
Vol. 4 of the DKV Conference Proceedings 2000 contains 19 papers on air quality, thermal comfort, space HVAC engineering and alternative cooling concepts. [German] Der Band 4 des DKV-Tagungsberichts 2000 enthaelt 19 Beitraege. Sie befassen sich mit speziellen Themen der Heiztechnik; Luftqualitaet und Behaglichkeit; Raumlufttechnik und Alternativen Kuehlkonzepten.
The results make appear that the cesium 137 would be eliminated less quick than what the ICRP considered for its models. Pectin would accelerate the cesium elimination but less quick than what is announced by its promotors. Politically speaking, the pectin is ignored by the officials of medicine and radiation protection at the pretext that its efficiency is not proved but no study is made. (N.C.)
This book of proceedings reports on 7 papers on combustion chemistry and formation of pollutants presented during the workshop organized by the `Combustion and Flames` section of the French society of thermal engineers. The chemistry of combustion is analyzed in various situations such as: turbojet engines, spark ignition engines, industrial burners, gas turbines etc... Numerical simulation is used to understand the physico-chemical processes involved in combustion, to describe the kinetics of oxidation, combustion and flame propagation, and to predict the formation of pollutants. (J.S.)
We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).
This report completes the documentation for the research project 'High Pressure Compressor - Preliminary Design as Basis for the Development of an Efficient and Environmentally Friendly Core Engine' which was funded by the Ministry of Economics of State Brandenburg. The objective of the project is to deliver a preliminary compressor aerodynamic design as well as design studies for an efficient, weight and cost improved compressor. The increase of stage pressure ratio and improved efficiency, whilst stage and blade count is reduced, has been achieved by advanced 3D methods. Compressor stability also at off-design conditions will be retained. The mechanical design focusses on a cost and weight optimised rotor not only for a conventional bladed discs but also for Blish stages. Various options for split casings have been developed and assessed. Alternative vortex reducers based on different design options have been carried out. The results from this project will be ...
On the 28{sup th} of May in 1998, the regulation of the ''Application of roof bolt support in coal mines'' came into force. Afterwards, the new roof bolt permission guidelines have been worked out by the Landesoberbergamt (Inspectorate of mines) in co-operation with the Deutsche Montan Technologie GmbH, with the Deutsche Steinkohle AG and with bolt manufacturers. These guidelines have been put into force on the 31{sup st} of August in 2000. Topics of this paper are the new regulation and first experiences. (orig.) [German] Nach der Erarbeitung der ''Richtlinien ueber die Verwendung von Ankerausbau im Steinkohlenbergbau (Anker-Richtlinien)'' vom 28. Mai 1998 wurden unverzueglich auch die ''Richtlinien ueber die Genehmigung von Ankerausbau (Ankergenehmigungs-Richtlinien)'' in Angriff genommen. Diese Richtlinien, die das Landesoberbergamt NRW gemeinsam mit Fachleuten der Deutschen ...
The ECOTEC combustion system and the architecture of the new Opel 2.2 l aluminum engine have been configured to achieve low noise and exhaust emissions. This power unit, employed in Germany for the first time in the Astra Coupe, already complies with the Euro IV emissions standard. It features minimum maintenance requirements and a long operating life. The DOHC spark-ignition engine with four valves per cylinder has two chain-driven camshafts, valve gear with roller cam followers and hydraulic lash adjusters. Two chain driven balancer shafts have been integrated into the engine block. The cylinder head and block, lower crankcase, oil pan, and cylinder head cover are all made of aluminum. A modular concept makes it possible to adapt the engine effectively to different vehicle concepts and markets. (orig.) [German] Das ECOTEC-Verbrennungssystem und die Motorarchitektur des neuen 2,2-l-Aluminium-Triebwerks von Opel sind auf niedrige Geraeusch- und Abgasemissionen ...
The ERICAM model (Environmental Risk Internalization through Capital Markets) includes the capital markets as a source contributing to the coverage of risks due to nuclear activites, thus enhancing the effectiveness and functions of the nuclear liability law. The model proposed will allow higher amounts for compensation and will increase financial security, flow of information, and efficient use of resources. The implementation of the model can be achieved on the financing side by issuing Nuke bonds, linking accident-specific options to government bonds. This will essentially increase the risk coverage compared to present means, and will be a pin-pointed addition to the existing layer system. There are three institutions proposed to act as mediators in the implementation of the model: A government authority to supervise the trade in Nuke bonds. Risk-bearing associations in oder to enhance the model`s efficiency, and to reduce transaction costs. Rating agencies that will reduce the ...
The study presented in this thesis is a contribution about the analysis of failures modes of electrolytic capacitors and thyristors. The studied components are main elements of the protection system of the superconductive magnets of the LHC. The study of the ageing of the electrolytic capacitors has shown that their reliability is strongly related to their technological characteristic. Evolution of their principal indicator of ageing (ESR) can be modeled according to different laws chosen according to their running mode. It appears that the prediction of failure of these components other than that due to wear can be only statistical taking into account the many causes of failure involving various modes of failure. In order to be able to evaluate influence of the ageing of the electrolytic capacitors on a system, simple models taking into account this parameters as well as the effective temperature of the component are proposed. An acceptable precision taking into account the simplicity ...
It is demonstrated that highly dispersed molybdenum sulfide catalysts are prepared by using Mo(CO){sub 6} adsorbed on the support. The structure of ultradispersed molybdenum sulfide is suggested by EXAFS techniques to be different from that of MoS{sub 2}. The TOF of the thiophene HDS is almost invariant with the dispersion of molybdenum sulfide at a high molybdenum dispersion, whereas the TOF of the hydrogenation greatly increases with increasing dispersion. On the basis of the HDS activity and optimum Co/Mo ratio of Co-Mo/Al{sub 2}O{sub 3} catalysts having a variety of molybdenum dispersion fabricated by using carbonyl complexes, it is demonstrated that highly active HDS catalysts are prepared by highly dispersing molybdenum sulfide phases. Edge decorations of molybdenum sulfides by cobalt are suggested for the synergy generation between cobalt and molybdenum sulfides. (orig.) [Deutsch] Unter Verwendung von auf dem Traeger adsorbierten Mo(CO){sub 6} lassen sich hochdispergierte ...
Policy strategies for the promotion of electricity from renewable energy sources differ significantly among the Member States of the European Union with respect to the amount of additional installed capacity as well as concerning the country-specific support costs. The present report aims to assess the effectiveness and the economic efficiency of the support policies in the EU based on both historical experiences and prospective model-based analysis. The main message of the investigation is that the most effective policy instruments tend to be cost-efficient at the same time. In particular, feed-in tariff systems were identified as a successful instrument for supporting renewable energies in terms of effectiveness and efficiency, whereas quota systems still have to prove themselves in practice. (orig.) [German] Bezueglich des Erfolges bei der Foerderung erneuerbarer Energietraeger im Stromsektor bestehen deutliche Unterschiede zwischen den Mitgliedsstaaten der ...
It is necessary to measure strength and creep behavior to guarantee the safe and reliable usage of refractory alloys at extremely high temperatures. In the literature there is very little information available about the properties of Mo-Re alloys at temperatures higher than 1000 C. A special test facility has been designed and built for stress-rupture testing at very high temperatures (up to 3000 C) of refractory metals and alloys in inert atmospheres. - The stress-rupture strength as well as the creep behavior of molybdenum-rhenium alloys with rhenium contents between 41 and 51 wt.% have been determined at temperatures ranging from 1200 to 2000 C, and rupture times of up to 10 hours using this facility. Previous measurements of stress-rupture strength and creep behavior of pure rhenium have been compared with the measurement results of Mo-Re alloys. - The discussion of the values measured is based on metallographic test results and scanning electron microscopy (SEM) images of Mo-Re ...
The typical MRI features of the most common pancreatic diseases, such as pancreatitis and adenocarcinoma of the pancreas, have been established. However, even in these common pancreatic disorders, MRI correlation with the underlying pathology is limited for clinical reasons. We emphasize MR-pathological correlation of inflammatory and neoplastic pancreatic changes, including pancreatitis, adenocarcinoma, acinar cell carcinoma, rare cystic and solid pancreatic neoplasms, and islet cell tumors. By highlighting the correlation of key pathological features with MR findings, a better understanding of the MR appearance of pancreatic pathology can be provided. In addition, MRI may prove a powerful tool in detection and characterization of pancreatic tumors. (orig.) [Deutsch] Das MR-tomographische Erscheinungsbild von Pankreatitiden und Adenokarzinomen des Pankreas, als den haeufigsten Pankreaserkrankungen, ist zwar ausreichend bekannt; allerdings ist selbst bei diesen ...
A process model is presented and used for identifying options for controlling the cupola furnace process and for investigating natural gas substitutes. Fuel substitution will affect temperature curves (i.e. tapping temperatures and melting capacity), outlet temperatures and gas mass flow out of the preheating zone. The contribution presents several process variations to overcome these problems and compares them with the natural gas process. [German] Mit dem Prozessmodell werden zunaechst Moeglichkeiten der Steuerung von Abstichtemperatur und Schmelzleistung, insbesondere unter Beruecksichtigung der Schrottqualitaet (spezifische Oberflaeche a{sub G}), untersucht. Es wird gezeigt, dass das Prozessmodell die Ergebnisse aus der Praxis wiedergibt. Daran anschliessend wird mit dem Prozessmodell die Substitution von Erdgas durch minderwertige Gase untersucht (Brennstoffsubstitution, Ressourcenschonung). Durch die Brennstoffsubstitution veraendern sich die Temperaturverlaeufe und damit auch ...
56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das Lig. talofibulare ...
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [Deutsch] Wasserkraftanlagen bedeuten Planung, Gestaltung, Ausfuehrung und Betrieb von Bauwerken und hydraulischen sowie elektrischen Maschinen. Ihre Typenvielfalt ...
In 1986, following comprehensive preliminary studies, a 17 MW battery energy storage plant was set up in the insular power supply system of Berlin (West) for the purpose of frequency and output control and provision of immediate reserve capacities. The present paper reports on the initial task, and the dimensioning and construction of this large-scale demonstration as well as the costs entailed in this. It also relates the experiences gained with the operation of the battery energy storage plant in its function as a fast-responding control unit and gives an account of its economic efficiency. Recent studies on the economic efficiency of the plant in conditions as they exist in the present interconnected power supply system are presented. Finally the author reports on the experiences gained with individual plant components, i.e., battery, battery periphery, and power converter and quantifies the cost of plant operation, maintenance, and servicing. (orig./HW) [Deutsch] Im Inselnetz von ...
The precipitation of heavy metals as hydroxides is the standard technique for the decontamination of waste water streams polluted by these elements. On the other side, progress in research has been made concerning the biosorption onto dead biomass and bioprecipitation supported by physiologically active bacteria. As the aim of this study, a flexible strategy has been envisaged cleaning a waste water with definite heavy metal load underlying the process mentioned above. Suitable bacteria were enriched and the process was tested in a technical plant. As result, a very high efficiency of heavy metal elimination has been found. The field of application covered by the acquired process is identical with the whole range of the waste water streams polluted by heavy metals. In addition, a second stage may be necessary if there are any further contaminants to be removed. (orig.) [Deutsch] Bei der Reinigung von schwermetallhaltigen Abwaessern ist der derzeitige Stand der Technik gegeben durch die ...
This report presents the results of the BMBF-sponsored project Fundamentals and models for assessing the effect of climate changes on soil, plant development and the crops of an economically significant range of farm products. Its aim was to study, by means of the results obtained for winter wheat, the dependence of plant growth on temperature, radiation and water as well as nutrient supply for other economically important crop types. Building on this, process-oriented, climate-sensitive agricultural ecosystem models for winter rye, winter barley, sugar-beet and winter intercrops were developed, verified and, in some sites, validated. First scenario calculations served to demonstrate the climate sensitivity of these models. (orig./KW) [Deutsch] Im vorliegenden Bericht werden die Ergebnisse des BMBF - Vorhabens `Grundlagen und Modelle zur Abschaetzung von Klimaaenderungen auf den Boden, die Pflanzenentwicklung sowie den verwertbaren Ernteertrag einer wirtschaftlich ...
The g factors of the 2_1"+ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g("8"4Sr)= + 0.419(47), g("8"6Sr)= + 0.273(50) and g("8"8Sr)= + 1.15(17). The mean lifetimes of the 2_1"+ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions. (author).
A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was calibrated with ...
The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the features and performance of the models ...
The objectives of this study were to estimate symbiotic nitrogen fixation by two common pasture legumes, Trifolium subterraneum L. and Medicago truncatula Gaertn., and an Australian native legume, Acacia dealbata Link, growing in pots using an indirect isotopic method. This method was also used to calibrate the C2H2 reduction assay of the intact plants. In addition, hydrogen evolution was measured in an attempt to explain the variations in C2H2:N2 ratios between the species. 25 refs.; 1 figure; 4 tabs.
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
The sequence of events from the assembly of a space nuclear power system to its integration in the Space Shuttle Transportation System (STS) is considered. First, the sequence followed for SNAP-10A, the only free world space reactor electric power system ever launched and operated in space, is reviewed. Before shipment, the SNAP-10A reactor was raised to operating temperature using electrically supplied heat and operated at low power for control calibration. Next we discuss shipment to the launch site, a phase that is critical because of the potential for various accidents. Once the power system arrives at the launch site, the processing sequence is performed. This sequence includes checkout, mating with the payload or upper stage launch vehicle, and integration into the STS.
A distributed watershed hydrologic model soil and water assessment tool (SWAT, 2000 Version) was applied to simulate stream flow and nutrient loadings (including total nitrogen (TN) and total phosphorus (TP)) in Gucheng Lake Basin, which is located in the lower reach of Yangtze River Basin. Model parameters related to stream flow and nutrient loadings were calibrated and validated by the observed value, and the simulation showed that the simulated values were reasonably comparable to the observed data, suggesting the validity of SWAT model. The simulated surface runoff and nutrient yield between two stages, viz. 1981-2000 and 1951-1960, were compared, basically considering land reclamation in the mid-1970s. The result indicated that, the average annual runoff and output of TN and TP in 198...
Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...
In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
Reliability analysis is now being used to a large extent for several civil engineering structures. Such analysis has not been used for rockfill dams, the most common dams in Norway. Following work on reliability analysis for breakwaters, reliability analysis was then used to investigate the ability of the stone material on the upstream face of a rockfill dam to withstand wind generated waves. An attempt is made to follow up this work by including discharge overtopping on a rockfill dam in a reliability analysis. This report primarily goes through previous work on the required weight of protective stones on the downstream face of the dam for specified discharges over the dam and also deals with the probability formulation of extreme floods. A failure function with partial coefficients is formulated. But for reasons of economy the calibration of the partial coefficients remains for a next phase of the project. 14 refs., 17 figs.
The theory of a method of determination of the reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mock-up of a liquid-metal fast breeder reactor and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mock-up, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies, to approximately 30 dollars subcritical.
The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material
The general objective of this workshop is to investigate and discuss methods by which uncertainties in mass balance models for toxics in the Great Lakes may be reduced. As described by the workshop prospectus, this paper is focused on problems of reducing (and quantifying) uncertainty as they relate to in situ field observations/system response measurements for the establishment of initial conditions, boundary conditions, calibration/confirmation data sets, and model post-audit data sets.'' I have taken this description to refer not only to the evaluation of uncertainty in the field observations themselves, but also to the uncertainty associated the analyses of in situ observations as they interact in the overall modeling process. Thus, I will be concerned here with quantification and reduction of uncertainty both (1) as they may be applied to descriptions of the system that is being modeled and (2) as they may be associated with model ...
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce exceptional fuel economy.
We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...
Two natural gas/diesel dual fuel conversion systems for the Detroit Diesel 6V-71 transit bus engine were described. The basic concept of a dual fuel engine was to operate a diesel engine with both liquid fuel injection and a lean premixed gas mixture. The engine achieved high efficiency due to the high compression ratio typical of the diesel engine. Test results were obtained using three different calibrations on one engine. The objectives were to match existing engine performance with improved emissions and better overall fuel economics. Results showed that overall, engine conversion has both economic and emissions advantages over a straight diesel engine. However, the durability and in-use applicability of the system remains to be demonstrated with an in-bus demonstration project.. 3 tabs., 4 figs.
The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...
The use of numerical modeling in oil spill incidents is a well established technique that has proven to provide cost-effective and reasonable estimates of oil surface drift. Good predictability of such models depends highly on the quality of the input data of the incident and on the model calibration effort. This paper presents the results of simulating oil spillage trajectory in the Arabian (Persian) Gulf. The study employed a 3-D rectilinear hydrodynamic model combined with oil spill model. Typical representative environmental conditions of the Arabian Gulf were first setup into a hydrodynamic circulation model using data from various sources. The performance of the hydrodynamic model was then tested against measurements of tidal fluctuation and sea currents at selected locations. The sp...
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.
This report gives a brief introduction to the project `Probabilistic Design Tool for Wind Turbines` - PRODETO - which was carried out during the years 1996-98 with partial funding from the European Commission under the Non-Nuclear Energy Programme JOULE III. The report gives an overview of the objectives and motivation for the project, and the methodology used. In this context, an example of reliability-based wind turbine design against fatigue failure is outlined with emphasis on the various important steps herein, which include probabilistic load and resistance modelling, calculation of failure probability, and calibration of partial safety factors for use with a deterministic design code format. The results of the project are presented with emphasis on a developed computer program and its capabilities, and the various elements of an executed case study are outlined. A list of project reports concludes the report. (au)
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise ...
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.
This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic ...
The preparation and luminescence properties of crystal phosphors based on alkali metal iodide and calcium oxide substrates were studied. The highest luminescence intensities were achieved with iodide substrates at 200/sup 0/ and with the calcium oxide substrate at 800/sup 0/. The calibration graphs were linear in the thallium concentration ranges 0.03-5.0 and 0.1-2.0 mu g using sodium and potassium oxides, respectively, and in the range 0.05-5 mu g using cesium iodide and calcium oxide. A method is proposed for the determination of down to 3 x 10/sup -4/% thallium in rocks, using a crystal phosphor with sodium iodide substrate.
Theoretical and experimental research efforts in evaluating an innovative concept for vertical axis wind turbines (VAWT) are described. The concept is that of using straight blades composed of circulation controlled airfoil sections. The theoretical analysis has been developed to determine the unsteady lift and moment characteristics of multiple-blade cross-flow wind turbines. To determine the drag data needed as input to the theoretical analysis, an outdoor test model VAWT has been constructed; design details, instrumentation, and calibration results are reported. Initial testing is with fixed pitch blades having cross-sections of conventional symmetrical airfoils. Costs of building the test model are included, as well as estimates for blades constructed with composite materials. These costs are compared with those of other types of wind turbines.
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
The g factors of the 2/sub 1//sup +/ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g(/sup 84/Sr)= + 0.419(47), g(/sup 86/Sr)= + 0.273(50) and g(/sup 88/Sr)= + 1.15(17). The mean lifetimes of the 2/sub 1//sup +/ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions.
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
A stable chlorobenzene dispersion of conducting polyaniline (PANI) has been obtained by doping emeraldine base with dodecylbenzene sulfonic acid (DBSA) and studied by spectrophotometric measurements in the UV-vis-IR range. The electrical properties of PANI: DBSA films obtained from the above dispersion have been investigated under different temperature and relative humidity conditions. All-organic chemoresistive devices have been developed by spin-coating the PANI: DBSA dispersion on flexible substrates, and then by depositing electrodes on the top, from a carbon nanotube conducting ink. Sensing tests performed under exposition to calibrated amounts of ammonia reveal that these simple and inexpensive sensors are able to detect ammonia at room temperature in a reliable way, with a sensitivity linearly related to concentration in the range between 5 ppm and 70 ppm.
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which gives rise to a medical ...
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...
In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
Electric utility plants, for which construction commenced after September 18, 1978, must install and operate continuous emission monitoring (CEM) systems to demonstrate compliance with SO_2 and NO_x emission standards. Furthermore, effective December 4, 1987, each plant must develop and implement a CEM quality assurance (QA) program. This paper reviews the CEM and QA requirements set forth by new source performance standards (NSPS) promulgated by the Environmental Protection Agency. The paper summarizes operating characteristics of the 32 power plants currently subject to NSPS and describes the types of CEM systems used by these plants. Also, to the extent available, the paper presents the results of initial (i.e., first quarter 1988) QA activities (e.g., audits and calibration drift assessments) conducted by these plants.
The Cycle 8A static tests conducted in the Fast Flux Test Facility (FFTF) during 1986 have resulted in the separation of various feedback reactivity components. These feedback components, described by closed-form equations depending only on the reactor temperature field, can be regarded as database for the validation and/or calibration of feedback mechanistic models. The SASSYS safety analysis code contains the most developed feedback reactivity models and was selected for the comparison study between database and mechanistic calculations for the FFTF. Although detailed feedback models for control rod repositioning and core radial expansion/bowing exist, only the simple models were available in SASSYS at the time of this study. The results are described in this paper.
A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.
The Jeanne d`Arc Basin is located 320 km offshore in the Grand Banks of Newfoundland. It is a Mesozoic failed-rift basin with recoverable oil reserves of about 2 billion barrels. Its huge Hibernia Field will be in production by late 1997. The basin has been reappraised using sequence stratigraphic concepts, and renewed exploration in the area is expected. The Upper Jurassic - Lower Cretaceous sedimentary accumulation in the Basin was formed by the extensional tectonics that created the North Atlantic Ocean. The sedimentary packages were placed in chronostratigraphic order by calibrating the biostratigraphy of the Oxfordian to Maastrichtian section to the detailed ammonite zonation from the North Sea.
The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous ...
This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.
In view of no satisfactory mathematical model is presently available for the dose-response curve of immunoradiometric assay, a three parameter model based on single binding site mass action law has been derived. A curve fitting method based on similar principle of linear robust regression was designed and a software was prepared for use on IBM personal computers. Experiments revealed that the model is applicable to a variety of IRMA systems as well as to time-resolved immunofluorometric assay of hAFP. When there was outlier(s) of the calibration curve, the average bias of unknown samples obtained with this method is significantly smaller than methods using four parameter logistic model or four parameter single site mass action model.
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured shear wall height. 14 refs., 11 figs.
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to ...
Purpose: {sup 31}P-MRS is used to assess the influence of sex and age on quadriceps muscle metabolism before and after exercise. Materials and Methods: 32 healthy volunteers (15 women, 17 men; mean age: 38{+-}17 yrs.) were examined by dynamic phosphorus-31 ({sup 31}P) magnetic resonance spectroscopy (MRS). In the magnet, the quadriceps muscle was stressed by an isometric and an isotonic form of exercise until exhaustion, respectively. Results: Resting conditions: With increasing subjects` age, the ratio {beta}-adenosine triphosphate/total phosphate decreased (r=-0.37; p=0.02). With increasing subjects` age, the ratios inorganic phosphate/phosphocreatine (r=0.79; p=5x10{sup -8}), phosphomonoester/{beta}-adenosine triphosphate (r=0.74; p=10{sup -6}) and phosphodiester/{beta}-adenosine triphosphate (r=0.62; p=10{sup -4}) increased. The pH was the only one of the evaluated spectroscopic parameters which showed a sex-dependence: Female subjects had a significantly lower pH (7.03{+-}0.02) ...
This paper describes a 1993 field experiment entitled Marine Aerosol Properties and Thermal Imager Performance Trial (MAPTIP) conducted by NATO AC/243 Panel 04/RSG.8 and 04/RSG.5 in the Dutch coastal waters. Objectives were: to improve and validate vertical marine aerosol models by providing an extensive set of aerosol and meteorological measurements, within a coastal environment at different altitudes and for a range of meteorological conditions; make aerosol and meteorological observations in the first 10 m of the ocean surface with a view to extending existing aerosol models to incorporate near-surface effects; and to assess marine boundary layer effects on thermal Imaging systems. Aerosol and meteorological instruments, as well as thermal imagers and calibrated targets, were utilized. This network of instrumentation has provided a comprehensive database of aerosol size distribution profiles and relevant meteorological variables throughout the marine atmospheric ...
The K site near Seoul began landfilling in 1992. The landfilled wastes include municipal solid waste (66.4%), construction residues (20.4%), water and wastewater sludges (trace levels), and hazardous waste (trace levels). The water content of the municipal solid waste is very high (47.3%); as a result, the leachate level (average E.L.) of the landfill, the design value of which is 7.0 m, was measured at 10.3 m in January 1995 and is increasing. The increase of leachate level in the landfill site causes a problem with slope stability. The leachate level at each disposal stage divided by the intermediate cover layer was calculated with the HELP (Hydrologic Evaluation of Landfill Performance) model and calibrated with the data measured from February 1993 to June 1995. Also, the hydraulic conductivities of the waste layer and the intermediate cover layer in each stage were calibrated continuously with HELP model analysis. To verify these results, ...
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, individual waves are imaged and the ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...
The shock-induced {alpha}(bcc){r_arrow}{var_epsilon}(hcp) transition in iron begins at 13 GPa on the Hugoniot. In the two-phase region above 13 GPa, the Hugoniot lies well above the equilibrium surface defined by G{sub {alpha}}=G{sub {var_epsilon}}, with G the Gibbs free energy. Also, the phase transition relaxation time {tau} is uncertain, with estimates ranging from {lt}50 ns to {approx}180 ns. Here we present an extensive study of these important aspects, metastability and dynamics, of the {alpha}-{var_epsilon} transition in iron. Our primary theoretical tools are (a) accurate theoretically based free energies for {alpha} and {var_epsilon} phases of iron and (b) accurate calculations of the wave evolution following planar impacts. We define metastable surfaces for forward and reverse transitions by the condition that the thermodynamic driving force G{sub {alpha}}{minus}G{sub {var_epsilon}} is just balanced by an opposing force resulting from elastic stresses, and we ...
Continental facies of Scythian-early Anisian age (Buntsandstein) of East of the Paris Basin form the underground gas storage reservoir exploited by Gaz de France in the area of Nancy (east of France). An accurate sedimentological study and the application of Genetic Stratigraphy principles lead to the understanding of the deposition of fluvial, which form the reservoirs, and to the reconstruction of their geometries. The subsurface data are calibrated on outcrops. Three types of fluvial systems (braided, sinuous to straight and anastomosed) are defined. A special focus on anastomosed channels permits to differentiate a proximal and a distal facies. Study of laterally continuous outcrops induces recurrent cycles of thickness, velocity and time variations (few tens to hundred ka). These correspond to the highest frequence stratigraphic units, i.e. parasequences or genetic units. Maximum of channel and levee presentation occurs during base-level rise: base-level fall ...
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International ...
The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document ...
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of the parameters should also be as easy as possible to interpret. The models are to ...
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical ...
A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric ...
We investigated summer activity patterns in a panel of volunteers drawn from a population segment with potentially high exposure to ambient oxidant pollution. The subjects were 15 men and 5 women aged 19-50, all of whom worked outdoors in the Los Angeles area at least 10 hr per week. The general approach was to (i) calibrate the relationship between ventilation rate (VR) and heart rate (HR) for each subject in controlled exercise; (ii) have subjects monitor their own normal activities with diaries and electronic HR recorders; (iii) estimate VR from HR recordings; and (iv) relate VR with diary descriptions of activities. Calibration data were fit to the equation log (VR) = (intercept) + (slope x HR), intercept and slope being determined separately for each individual to provide a specific equation to predict her/his VR from measured HR. Individuals' correlation coefficients relating log (VR) with HR ranged from 0.83 to 0.95. Subjects ...
SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface water system at Forsmark is described with the one-dimensional ...
In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...
Normally, the alloy NiMo28 is used in the solution annealed and quenched condition in which it has a face centred cubic matrix structure. The matrix of the material is supersaturated with molybdenum and, at temperatures above 800 C, has a tendency to form intermetallic precipitates such as the Ni{sub 4}Mo-ordered phase leading to the embrittlement of the NiMo28-ordered phase leading to the embrittlement of the NiMo28 alloy during hot working. For this reason, the aim of these investigations was to optimise the alloy by reducing its tendency to embrittle. The TEM-analyses carried out served to investigate the precipitation of the material as a function of its iron content after ageing at 700 C. The change in hardness and in the lattice constants of the NiMo28-specimens with iron content were also determined. To improve the hot working properties of this material it is recommended that the iron content be kept to about 3.2 mass % in order to reduce the tendency of the alloy to ...
DMT has developed what is called the stepped reforming process. This is an allothermal gasification process which uses hydrogen for a gasification medium. First the biomass is pyrolised by means of a heat transfer material. The escaping gaseous and condensable constituents are hydrogenated, heated in a reforming stage and are made to react to a hydrogen-rich product gas by means of homogeneous gasification. The heat required for this is provided by burning the pyrolysis coke. This makes it possible to dispense with process stages that would involve gasification of solid material and hence require higher pressure levels. The present process also works at ambient pressure. Moreover, stepped reforming promises a number of additional advantages: low-tar product gas containing 60% hydrogen, high cold gas efficiency, no wastewater arisings, robust operating behaviour. This paper outlines the basic ideas that led to the development of stepped reforming process and describes its diverse ...
In the year 1996 the spheres of competence of several DLR-Institutes working in the areas of fluid dynamics, reaction kinetics, combustion, numerical methods and laser measuring techniques have been brought together while contributing to the internal DLR project 'combustion chamber modelling (BKM)', in order to proceed with the computational simulation of combustion processes in combustion chambers of gas turbines. The main issue was the development of a research code for numerical simulation of fluid flow in real combustion chambers. Here the development of computational models of physical and chemical processes was emphasized, among other processes the formation of soot was treated. Moreover, a worldwide outstanding database of measured data for the purpose of code validation has been created within the framework of the BKM project using the laboratory facilities of the DLR, which are in Germany unique for the experimental investigation of the various processes in ...
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens ...
Preserving customers` investments in capital goods is one of the strategic market services offered by ABB, and to this end the company has developed project-specific retrofit concepts especially for older power generation plant. A prime example of such a modernization is the Umm Al Nar East (UANE) combined cycle power station in Abu Dhabi, UAE. UANE has two gas turbines of type GT13D, which together generate 140 MW of electrical energy, and heat-recovery boilers which supply steam to a seawater desalination plant with a capacity of 80 million liters of drinking water per day. After almost 20 years in operation, UANE is being modernized. To address the owner`s concerns and minimize plant downtime, ABB has introduced Service, Operation and Rehabilitation (SOR) Key Account Management for Abu Dhabi. In the first phase of the modernization project, the static starting equipment was upgraded and the mechanical turbine governor replaced by the EGATROL electro-hydraulic control system. Also, ...
In comparison to deterministic criteria, probabilistic reliability indices like interruption frequency and unavailability give a more differentiated insight into reliability in an electrical energy network. One possibility for network planning based on these indices is the definition of limits for customer nodes, another is the monetarisation of reliability in terms of interruption costs. Because of numerous disadvantages, interruption cost methods could not up to now win broad recognition in network planning in Western Europe. A more recent method for the monetarisation of reliability circumventing most of these disadvantages is the insurance system. In this system the customer selects a tariff class in an insurance system, and the utility reimburses its customers in the case of an interruption. In its first section, the paper describes a method for the flexible and realistic optimisation of MV networks. This method based on Genetic optimisation is able to integrate probabilistic ...
Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. Especially for follow-up examinations in ...
Tribological performance of alumina and silicon carbide ceramics as well as of the hardened steel 100Cr6 for reference was studied during reciprocating sliding and cavitation erosion in isooctane as substitute of gasoline and in distilled water. It was the aim to characterize effects of surface finish of the specimens and the liquid media on friction, resistance to sliding wear and cavitation erosion. Sliding wear tests were run on the self-mated ceramics and ceramic/steel pairs under conditions of boundary lubrication using a laboratory tribometer with cylinder-on-plate geometry. Vibratory cavitation erosion tests were conducted according to ASTM G 32-92. High initial surface roughness of coarse ground specimens led to a distinct running-in period during sliding contact with a transition from high to low values of friction coefficient and wear intensity. Incubation time was reduced with increasing surface roughness in the cavitation tests. Depending on the materials investigated, the ...
The influences of temperature and duration of tempering on hardness and microstructure were investigated at high-temperature martensitic and low-carbon steels with 9% chrome and the further alloying elements molybdenium, vanadium, niobium and partially tungsten. After austenitizing and subsequent air cooling the steels were tempered at temperatures below, at and above Ac{sub 1b} for different times and finally a hardness test was performed. Making use of the temperature dependence of the hardness tempering diagrams were constructed and the Hollomon-Jaffe-Parameter on the three steels was determined within its application limits. Micrographs of the structure shows the formation of the carbides and the martensite. At tempering temperatures below Ac{sub 1b} a decrease of hardness occurs, above Ac{sub 1b}, a hardness rise due to the partial austenitizing was obtained. While hardening below Ac{sub 1b}, the tempering quality increases from P 91, NF 616 to E 911. (orig.) [Deutsch] An ...
FLUTAN is a highly vectorized computer code for 3D fluiddynamic and thermal-hydraulic analyses in Cartesian or cylinder coordinates. It is related to the family of COMMIX codes originally developed at Argonne National Laboratory, USA, and particularly to COMMIX-1A and COMMIX-1B, which were made available to FZK in the frame of cooperation contracts within the fast reactor safety field. FLUTAN 2.0 is an improved version of the FLUTAN code released in 1992. It offers some additional innovations, e.g. the QUICK-LECUSSO-FRAM techniques for reducing numerical diffusion in the k-{epsilon} turbulence model equations; a higher sophisticated wall model for specifying a mass flow outside the surface walls together with its flow path and its associated inlet and outlet flow temperatures; and a revised and upgraded pressure boundary condition to fully include the outlet cells in the solution process of the conservation equations. Last but not least, a so-called visualization option based on VISART ...
Already in 1998, the city of Hanover, the Stadtwerke Hannover and six further cities of the region initiated the funding programme 'Hannover proKlim' for promoting energy-relevant modernization measures in domestic buildings. One year later, the social marketing campaign 'Haus-Partner Hannover / Der (H)Eissbaer'' was started, which addresses building owners in Hanover with the intention to induce them to action. The 'Energiepass Hannover' is another important instrument of the campaign. This report takes stock of the results achieved so far. [German] Beim Klimaschutz im Gebaeudebestand lassen sich in Hannover drei Ansaetze hervorheben, die parallel zueinander entwickelt wurden und die in besonderer Weise dazu beitragen, die CO{sub 2}-Emissionen im Gebaeudebestand zu reduzieren: Bereits 1998 hat die Landeshauptstadt Hannover gemeinsam mit den Stadtwerken Hannover und sechs weiteren Staedten der Region den Klimaschutz-Fonds ...
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. (orig./MG) ...
Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no complications were encountered. ...
The influence of a decarburisation process during austenitising of the through-hardenable rolling bearing steel 100Cr6 (SAE 52100) on the rim zone properties of the martensitic through-hardened material was investigated by means of material analysis and diffusion calculations. For this purpose, two specimens were prepared under defined heat treatment conditions, and the near-surface carbon distribution was determined micro-chemically by using secondary ion mass spectrometry (SIMS). In part 1 of the present work, these concentration profiles are compared with the depth variation of the micro-hardness and with the distance curves of the residual stresses and the line broadening ({l_brace}211{r_brace} {alpha}'-Fe diffraction line) both measured by X-ray diffraction (XRD). In addition, microstructure investigations were performed. In part 2, a refined kinetics model of a diffusion-controlled reaction based on the finite element method (FEM) will be applied to the decarburisation ...
Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial plateau and 3.5% ({+-}2.0%) in the lateral tibial plateau. The ...
Energy projects are extremely capitalistic and the costs involved have a significant weight on the balance sheets of companies. This paper describes the general rules of financing policies used by companies from the natural gas and petroleum industries: constraints (external and financial markets, partnership, warranties..); implication of financiers; risk analysis (political (nationalization, civil or military troubles, difficult transfer of profits outside the project..), financial (property developer, nature of the project, delay, cost overruns, performance, market..)); financial instruments (proper funds and debt, bankers and insurers, loans etc..). These rules are illustrated with several examples of recent projects of gas pipelines and exploitation of oil fields abroad. (J.S.)
The German National Group of the International Nuclear Law Association, AIDN/INLA, held its 10{sup th} regional conference in Celle on September 2 and 3, 2004. The event was attended by approx. 120 participants from twenty countries discussing 'the Internationalization of Nuclear Law'. Four sessions were devoted to in-depth studies of these topics: - Legal problems associated with the management of radioactive waste. - Regional nuclear safety vs. global nuclear safety. Do the Europeans need a supplementary EU regime of nuclear safety? - Liability and insurance in cases of nuclear damage. - Topical issues of German nuclear law. (orig.)
Different cooling speeds after previous solution annealing at 1130deg C for 0.5 hour were simulated in laboratory experiments. The following conditions were examined: (1) Direct water quenching, (2) cooling in air for 0.5 min to 950deg C/water quenching, (3) cooling in air for 1.5 min to 750deg C/water quenching, (4) cooling in furnace for 5 min to 750deg C/water quenching. The results of the investigations have shown that a variation of the cooling conditions causes considerable changes in the creep behaviour. (orig.).
The contribution attempts a definition of the concepts of ``technical facilities`` and ``facility management``. [Deutsch] Um mit der Ueberschrift zu beginnen: Was ist Gebaeudetechnik? Die Antwort ist nicht ganz einfach. An der TU Berlin gibt es einen Ingenieur-Studiengang mit dieser Bezeichnung. Es hat etwas mit dem Gebaeude, aber nicht viel mit Architektur zu tun, wie manchmal faelschlich angenommen wird. Um solche Missverstaendnisse gar nicht erst aufkommen zu lassen, hat sich die Gruppe des Vereins Deutscher Ingenieure, die sich mit der Gebaeudetechnik beschaeftigt, als `VDI-Gesellschaft Technische Gebaeudeausruestung` bezeichnet. (orig.)
TRITEX was a pumped loop with Pb-15.8Li, fabricated from steel 1.4922. In contact with the molten eutectic were also molybdenum, vanadium and armco-iron. The loop was originally designed to investigate tritium extraction using solid getter metals. Over the years the goal changed to the study of metals, corrosion products and purification of the eutectic mixture. Therefore many modifications were done. The first part of this report describes TRITEX. All parts were enclosed in thermoboxes for a homogeneous temperature. One test section was in an argon glove box and could be opened during operation. Other special equipment`s were: permeation membranes and liquid-metal-covergas-interfaces to study the transport of H{sub 2}, D{sub 2} and {sup 3}H, different purification devices, a quartz observation window to see the liquid metal surface, 4 different kinds of flow measurements, level indicators, freeze valves. The second part describes loop operation. Between 1989 and 1996, the eutectic ...
We have studied freshly prepared lysozyme solutions in heavy water for two NaCl concentrations as a function of temperature. Lysozyme solubilities in this solvent are determined by static light scattering. By small angle neutron scattering, we evidence that interactions between lysozyme molecules are characterized by a second virial coefficient A{sub 2} whether the solution is under-saturated or supersaturated. From the variation of A{sub 2} as a function of temperature we have evaluated the enthalpy corresponding to the interaction between lysozyme molecules. We show that the interactions between protein molecules are higher in heavy water than in light water. (authors). 13 refs., 3 figs.
So far, publications in turbomachinery engineering have tended to neglect the description of control systems and strategies which could be converted into practical guidelines for turbine operation. The contribution describes the power station turbine as a basis for modelling the control stage. The solutions will serve as a basis for further type-specific investigations of the problem. [German] Eine vornehmlich regelungstechnisch ausgerichtete Beschreibung des thermodynamisch-mechanischen Wirkungsgeschehens im Bereich der Regelstufe von Dampfturbinen sowie deren Umsetzung in schluessige, betriebsrelevante Aussagen fehlen bislang in der Turbomaschinenliteratur. Im Beitrag werden am Beispiel der Kraftwerksturbine die Grundlagen fuer eine modelltechnische Nachbildung der Regelstufe entwickelt. Die Loesungen dienen als Ausgangsbasis fuer weitere typenspezifische Bearbeitungen dieses Problems. (orig.)
Facility management has long been regarded as a cost reduction measure, but it is also a means of raising the financial worth of a building so that landlords can get higher rents or sell the building at a better price. [German] Lange Zeit wurde Facility Management als eine Massnahme zur Kostensenkung angesehen. Heutzutage zeigt sich immer mehr, dass das Facility Management sehr viel umfassender zu verstehen ist: Der Wert eines Gebaeudes bemisst sich nicht allein an einer niedrigen Kostenquote, sondern er soll umfassend Investoren wie Mietern den hoechst moeglichen Nutzen bringen. Nicht allein der kostenguenstige Betrieb ist entscheidend, sondern der Wert des Gebaeudes muss insgesamt gesteigert werden. (orig.)
To make a quantitative comparison of risks between the SNR-300 and a modern PWR (Biblis B), the consequences of an accident or the extent of damage of a release of radionuclides to the environment due to an accident are estimated by computer programs for accident consequence models. The accident analysis includes an analysis of events for Bethe-Tait accidents with failure of the outer containment. The FGSB release rates are compared with those of the Society for Reactor Safety (GRS).
The passive films formed on 316L stainless steel in various NaCl solutions have been investigated by capacitance measurements (Mott-Schottky). Pitting parameters have been determined using the galvano-kinetic polarisation method. The obtained results reveal the existence of a shallow and a deep donor level localised in the band gap of the semiconducting oxide film. These energy levels are due to iron ions in the tetrahedral and octahedral positions. It also appears that the participation of the deep donor level effects the electric field. The study developed allows us to compare characteristic parameters of the electronic structure of the passive film to those related to pitting susceptibility. (authors) 25 refs.
The aim of this work was the examination of the coarse grain recrystallisation of the {gamma}-free ODS nickel-based alloy PM 1000 depending on the various parameters due to the processing during heat treatment. After isotropic hot compacting (HIP) of the mechanically alloyed powder, one observes a homogeneous sub-microscopic fine grain structure which can coarsen during high temperature heat treatment, due to sufficiently high driving force from the grain boundary energy via abnormal grain growth to 600 times its size. The setting of the elongated high temperature resistant recrystallisation structure is, however, not connected with this. The dependence of the sucess of re-crystallisation on the re-forming parameters (re-forming temperature and degree of re-forming) was shown by a socalled re-forming card. In order to achieve re-crystallisation to a coarse and aligned grain structure, apart from a certain absolute minimum degree of re-forming, the re-forming must occur within a defined ...
Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.
Calcium sulfate dihydrate which is co-produced in the scrubbing of waste gases from bituminous coal power plants is employed in the underground road securing after recrystallization. Beta-sulfate semi hydrate is obtained from the dihydrate by recrystallisation and it is used as such or as a stiff mixture with additives as a stowing material. Particularly fly ash from coal combustion units, washery refuses and development rocks from coal mining or slags from the metallurgical industry can be used as additives. The compressive and the bending tensile strength of the stowing material can be adjusted by the water content in case beta sulfate semihydrate is used as such.
The author investigates whether the international law regime so far has developed any legal principles dealing with the problem of the dumping of radioactive waste in the sub-seabed, and whether any of such provisions available adequately tackle the problem in the light of the gravity of danger emanating from radioactive waste. The study covers over 30 different texts of international treaties and protocols. Points of main interest are the London Dumping Convention and the Montego Bay Convention on the Law of the Sea. The author concludes that the disposal of radioactive waste into the seabed belongs to the permissible, although not specially allowed activities within the framework of the freedom of the high seas, and therefore urgently calls for establishing an international regulatory system pertaining to the planning and accomplishment of such activities. An outline legal concept of a regulatory system is explained. (orig./HSCH).
Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% (n=15) of patients ...
Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields (pumps, flow regulation). (author)
The biological treatment process was selected by Gaz de France (GDF), the French national gas utility, for the de-pollution of an old gas works where the main pollutants are coal tars containing polycyclic aromatic hydrocarbons. Microorganism-based biological treatment techniques may involve bio-reactors, static ground knolls (where oxygen is brought through drains) and dynamic knolls (where oxygenation is carried out by turning up the soil). Issues on sampling, sorting, process testing, site preparation, process control, etc. are reviewed
The dogmatic and constitutional basis as well as points of definition concerning the Technical Code Clean Air (TA Luft) are explained at first, followed by an assessment of the air pollution concentrations within the overall complex of the air pollution abatement measures, and an analyses of air pollution concentrations as a concretization of the state-of-the-art. In connection with the differentiation of the various applicability levels of TA Luft, the inhouse validy for authorities, the importance for law courts and, finally, the external binding effect for plant operators and possible third parties are discussed. At the center of attention are questions concerning validity claims and validity possibilities. (HSCH).
Chronic exposure to uranium compounds such as UO{sub 2} and U{sub 3}O{sub 8} led to the development of a methodology, based on the recommendation of ICRP, involving four main steps: the measurement of the uranium concentration and the particle size distribution at the workstation, the assessment of physico-chemical properties of the compound, the study of in-vitro solubility using a chemical test and the monitoring of workers. Results and comments on UO{sub 2} and U{sub 3}O{sub 8} are given. (author)
ResumeLa convergence des solutions faibles du systeme de Navier-Stokes-Fourier-Poisson compressible avec un terme de frottement est etudiee dans la limite dun frottement infini, la loi de pression incluant, comme cas particulier, celle correspondant aux particules de Fermi-Dirac. La limite se trouve etre une solution faible dun systeme de Smoluchowski-Poisson non isotherme, la temperature ne dependant que de la variable temporelle et etant determinee par la conservation de lenergie totale.
This work aimed to develop a fast-dissolving film made of low dextrose equivalent maltodextrins (MDX) containing nicotine hydrogen tartrate salt (NHT). Particular attention was given to the selection of the suitable taste-masking agent (TMA) and the characterisation of the ductility and flexibility under different mechanical stresses. MDX with two different dextrose equivalents (DEs), namely DE 6 and DE 12, were selected in order to evaluate the effect of polymer molecular weight on film tensile properties. The bitterness and astringency intensity of NHT and the suppression effect of several TMA were evaluated by a Taste-Sensing System. The films were characterised in term of NHT content, tensile properties, disintegration time and drug dissolution test. As expected, placebo films made of ...
Modern tubular type pumps commonly have lubricated radial bearings which require no compressed water supply and reduce the servicing requirements. Problems that may possibly result from entrained sand in the pumped fluid were solved with the development of ceramic Residur {sup trademark} bearngs in the early eighties. (orig.) [German] In zunehmendem Masse werden Rohrgehaeusepumpen mit foerdermediumgeschmierten Radiallagern ausgestattet, da dies z.B. neben dem Wegfall einer ansonsten notwendigen Druckwasserversorgung auch einen deutlichen reduzierten Wartungsaufwand nach sich zieht. Den Problemen durch eine moegliche Sandbeladung des Foerdermedium wurde bereits durch die Entwicklung der keramischen Residur {sup trademark} -Lager Anfang der 80er Jahre Rechnung getragen. (orig.)
Over the decades, basic research in life sciences has profited greatly from the study of the small unicellular fungal species Saccharomyces cerevisiae. This yeast turned out to be key for the identification and understanding of molecular mechanisms that underlay the basic functions of all eukaryotic cells. These include, but are not limited to, the regulatory mechanisms behind cellular reproduction (cell cycle control), cellular morphogenesis (cell polarity, cytoskeleton and membrane trafficking) and the management of cellular information (chromosome biology, transcription and translation). Rapid access to genomic information of many yeast species, combined with bioinformatics analyses, provide information on the evolutionary history of yeasts and the molecular ancestry of their constituen...
Economic and safe operation of nuclear power plants requires reliable steam turbines with high efficiencies. The progress in flow mechanics achieved over the past few years has allowed the use of powerful methods of flow calculation in developments of new blading with greatly enhanced efficiencies. Thanks to the latest manufacturing techniques, the newly developed blading systems can be produced at low cost. Next to progress in flow mechanics, also the broadbased use of advanced finite-element calculations resulted in a more thorough grasp of the many problems associated with structural mechanics assessment of steam turbine components. The theoretical methods have been supplemented by comprehensive efforts in fracture mechanics and experimental materials studies, thus helping to create a reliable knowledge base which will help to avoid the dreaded stress corrosion cracking phenomenon, in components of steam turbines. The measures introduced to improve operational reliability already in ...
Elektrochemische Potentialmessungen (auch Potentialfeldmessungen) haben sich seit Jahren bewahrt, Bereiche mit aktiver chloridinduzierter Korrosion an tausalzexponierten Bauwerken, wie z. B. Bruckentafeln sowie Zwischendecks und Bodenplatten von Parkhausern und Tiefgaragen nachzuweisen. Bereits 1990 erschien die erste Fassung des Merkblatts B3 der DGZfP. Das DAfStb Heft 422 (1991) - Prufung von Beton Empfehlungen und Hinweise zu DIN 1048 - enthielt die Potentialfeldmessung bzw. das Merkblatt B3 im Anhang. In Deutschland liegen somit zwei Jahrzehnte Erfahrungen mit den entsprechenden Regelwerken und naturlich auch in der praktischen Anwendung vor. In der Praxis zeigte sich jedoch auch, dass die Anwendung verbessert werden muss. Die Potentialmessung wurde vielfach sogar falsch durchgefuhrt, ...
Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of the cases. Single, combined and bland lesions were accurately ...
The law of the 30 December 1991 on the high activity long lived radioactive wastes reached the end. This synthesis final document presents the scientific and technological results, obtained still the end of 2005, on the separation and the transmutation of long lived radionuclides of high activity long lived radioactive wastes. It is organized in five chapters: a presentation of the context and the historical aspects, the researches, the objectives and the strategy of the axis 1, the researches results on the advanced separation, the researches results on the transmutation, the scenario of separation-transmutation and their environmental, technical and economical impacts. (A.L.B.)
Technical education in the preparatory classes for the technology-based 'baccalaureat' prioritize experimental teaching activities. With the option 'Genie Electrotechnique', the subjects always deal with systems or processes connected with the use of electrical energy. Among the different topics, a lighting system brings to many prospects which cover various points of the teaching syllabus. After defining and studying the technical object, it is necessary to consider the educational adaptation by a model whose reduction scale must take into account the dimensions, cost and security constraints. Thanks a concrete example this paper describes a tool that brings to test and confirm the small scale model. Some teaching activities can be then considered but never losing touch with the actual application. (author)
Zusammenfassung Eine genauere Untersuchung der bekannten Modelle isotropen Materialverhaltens (z.B. von Mises, Tresca, Mohr-Coulomb, Drucker-Prager usw.) zeigt, dass sie selten mit Versuchsergebnissen ?bereinstimmen. Modelle mit inkompressiblen Eigenschaften sch?tzen oft das Materialverhalten bei mehraxialen Zugbelastungen falsch ein. Beim Flie?en unter Druck liefern die Modelle mit kompressiblen Eigenschaften unzul?ssige Werte der Querkontraktionszahl. Erfahrungen zeigen, dass es schwierig ist, mehrdimensionales Materialverhalten bei h?ufig fehlenden Informationen werkstoffgerecht abzubilden. Viele Modelle liefern akzeptable Ergebnisse nur f?r bestimmte Bereiche des Spannungsraumes. Diese Beobachtung hat auf die Idee gef?hrt, ,,bew?hrte?? Modelle miteinander zu verbinden. In diesem Artike...
In a water well sunk in the Grafschaft Bentheim region of northern Germany, small volumes of methane were emitted regularly and large volumes of methane in eruptions at irregular intervals. After some extreme gas eruptions in 2002 and 2004, the Grafschaft Bentheim district government initiated a project to investigate underground conditions in the region between Nordhorn and Bad Bentheim in order to prevent potential hazards to the locals population. The main purpose of the project was to provide information on underground mechanisms as far as possible in order to develop long-term safety strategies for freshwater supply in the region. (orig.)
The program introduced here for determining and describing the multi-axial creep of pipes is based, on the one hand, on the results of the nuclear process heat prototype plant material program and, on the other hand, on the possible load conditions which arise for evaluating accidents or extreme working situations. The basis of a theoretical description of multi-axial creep is the invariant theory in which both the von Mises configuration change hypothesis and the Norton creep law are included. Combined tension and torsion are also considered in detail, the superimposition of cyclic stresses in the tensile threshold area is discussed and cases of partial relaxation are explained. Experimental results for the discussed loads are introduced, which have led to satisfactory agreement between theory and experiment. (orig./MM).
Diagnostic systems make it possible to recognize incipient faults in good time and help to increase the availability of power stations. The thermal efficiency and the effective terminal output are didicated by a number of influences. Deviations from the expected status can be identified via continuous recording of the operating parameters and calculation of derived data. An improved efficiency and economical load distribution lead to considerable cost savings. (orig.) [Deutsch] Die Verarbeitung von Messwerten und Signalen ermoeglicht eine umfassende Beurteilung des Anlagenzustandes und die Erkennung sich anbahnender Veraenderungen. Stoerungen, Schaeden oder eine unwirtschaftliche Betriebsweise koennen fruehzeitig erkannt werden. Erhoehte Verfuegbarkeit, geringerer Brennstoffverbrauch und optimierte Lastaufteilung bringen Kostenvorteile. (orig.)
The electrochemical performances of orthorhombic LiMnO{sub 2} compounds are analyzed in order to find a structural and/or morphological origin to the differences of electrochemical behaviours observed in compounds with different size of crystallites and different amounts of lattice defects. Energy capacity performances of 200 Ah/kg are reached for materials with crystallites of about 10{sup 7} Angstrom{sup 3} and with about 7% of defects, while energy capacities of only 80 Ah/kg are obtained for materials with ten times bigger crystallites. (J.S.) 3 refs.
Zusammenfassung Hintergrund Seit 2005 finden schriftliche Anfragen und Vor-Ort-Pr?fungen durch den Medizinischen Dienst der Krankenversicherungen (MDK) statt. Diese spiegeln in ihren Ver?nderungen sowohl die Erfahrung der Kassen mit dem G-DRG-System (G-DRG German Diagnosis Related Groups) als auch der zust?ndigen ?rztlichen Mitarbeiter und des Krankenhauscontrollings wider. Wir wollten aufarbeiten, welche Entwicklung die MDK-Pr?fungen seit 2005 genommen haben. Hierf?r wurden s?mtliche Pr?fberichte seit Einf?hrung der Pr?fungen ausgewertet. Ergebnisse W?hrend anfangs haupts?chlich Fragen zur Kodier- und Dokumentationsqualit?t erfolgten, werden jetzt ?berwiegend Fehlbelegungspr?fungen durchgef?hrt. Zwischenzeitlich wurden konsequent die unterschiedlichen Klinikbereiche gepr?ft. Die Anfragen ...
Mechanical ventilation in private homes was for many years a stepchild of air conditioning engineers. A decisive impulse for change came in January 1995 with the enactment of the new Thermal Insulation Ordinance which for the first time allows house owners to exceed the usual admissible annual heating requirement by a certain amount on the condition that they equip the house with mechanical ventilation systems. (orig.) [Deutsch] Ueber lange Jahre war die mechanische Wohnungslueftung ein Stiefkind der Raumlufttechnik. Einen entscheidenden Impuls gab erst die seit Januar 1995 gueltige Waermeschutzverordnung, die erstmals zulaesst, dass ein gewisses Quantum des Jahres-Heizwaermebedarfs durch den Einbau mechanischer Wohnungslueftungen kompensiert werden kann. (orig.)
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an in-plane resolution of ...
Three different guidelines define the methods to be used for the quantification of exposures due to the incorporation of radionuclides. The adoption of the Euratom-directive into German law requires the adaptation of these guidelines. With this process, the experiences with the practical application of these regulations must be taken into account. (orig.) [Deutsch] Die Ermittlung der Koerperdosis durch inkorporierte Radionuklide ist in drei Richtlinien des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit (BMU) geregelt. Die Umsetzung der Euratom-Direktive in deutsches Recht erfordert die Anpassung dieser Richtlinien. Dabei muessen die bisherigen Erfahrungen mit diesen Richtlinien beruecksichtigt werden. (orig.)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
Zusammenfassung Das Konzept der ?quivalenten Spannung (Vergleichsspannung) wird seit langem angewendet und hat sich bew?hrt. Ein wesentlicher Grund daf?r liegt darin, dass es u.?a. bei der Formulierung ph?nomenologischer Werkstoffmodelle weiterhilft. Von Nachteil ist, dass es weder mit physikalischen Prinzipien in Verbindung steht, noch Informationen ?ber die Mikrostruktur des Werkstoffs enth?lt. Trotzdem wurden zahlreiche Hypothesen zur Formulierung von ?quivalenten Spannungen in der Vergangenheit aufgestellt und in der Praxis mit unterschiedlichem Erfolg angewendet. Als Basis f?r die Systematisierung der zahlreichen Modelle hat Yu die Unified Strength Theory (UST) vorgeschlagen. Diese eignet sich, u.?a. inkompressibles inelastisches Materialverhalten sowie kompressible Werkstoffe mit unt...
Atomization of liquid fuel in aircraft engines requires application of airblast atomizers, where the kerosene is supplied into the shear layer between two swirling airstreams. The transfer of this functional principle towards gaseous fuel, as illustrated in Fig. 1, yielded a strong influence of the swirl arrangement of the airflows on flame stability and homogeneity of the fuel/air-mixture. Compared to the co-swirl configuration the flow field of the counter-swirl arrangement exhibits a marked increase of the mass flow recirculated in the internal recirculation zone and a reduction of its length in axial direction. This is attributed to the faster decay of tangential velocity maxima in case of counter-rotating airflows. This generates a stronger positive axial pressure gradient dp/dx, thus enhancing the internal recirculation zone. Analysis of local turbulence quantities yields a restriction of turbulent exchange to smaller radial sections and lower maximum values in the jet dominated ...
The study abstracted aims at analyzing the economic effects of energy policies using simulations. Emphasis is on assessing the effects of decisions in favour of an expanding electric power industry based on nuclear energy and hard coal. The study discusses alternative assumptions concerning the cost involved, pollution abatement measures, shutdown and dismantling costs etc. Input-output analyses make the simulation model a consistent vehicle. Besides, the model in question is characterized by its explaining the investment demand of the different sectors by referring to the continuous annual development of innovative technologies.
This guidebook concerns the design of air-conditioning and air-treatment installations in recent and old buildings. The design of indoor atmosphere treatment systems is based on a rigorous and safe methodology. The following aspects are reviewed: situation of ambient air treatment, different aspects of a project, humid-air technique, principles of air treatment, basic conditions for a successful project, determination of enthalpy and hydric loads of rooms, design of ambient treatment systems, cold water production using a thermodynamical system, aeraulics, hydraulics, acoustics, logics of operation, forecasting of energy consumptions, global management of air-conditioning installations, ambient air-treatment systems. (J.S.)
This document exposes the results of the fourth evaluation report of the working group II of the inter government experts group on the climatic change. This evaluation presents the today scientific understanding of the climatic change impacts on the humans and their adaptation ability and vulnerability. It is based on the GIEC evaluations and new knowledge added since the third evaluation report. (A.L.B.)
Two isothermal sections were prepared at 1000 and 1150 C showing the low-Zr phases of the system Fe-Al-Zr. The phase equilibria were determined by means of X-ray powder diffractometry and electron beam microanalysis. For initial characterisation of mechanical properties, hardness values are determined and added to the tabulated data. (orig./MM) [German] Es werden am Fe-Al-Zr-System zwei isotherme Schnitte durch den zirkoniumarmen Teil des Systems bei 1000 und 1150 C erstellt. Die auftretenden Phasengleichgewichte werden mit Hilfe der Roentgenpulverdiffraktometrie und Elektronenstrahlmikroanalyse aufgeklaert. Zusaetzlich werden zur ersten Charakterisierung der mechanischen Eigenschaften Haertewerte bestimmt.
The quantitative measurement of carbon concentration-distance curves serves as fundamental prerequisite for the evaluation of rim zone properties connected with decarburisation processes in material science. This was shown in part 1 of the present work with two samples from through-hardenable rolling bearing steel 100Cr6 (SAE 52100) austenitised in different oxidising atmospheres by position dependent determination of hardness, residual stresses, and X-ray line broadening ({l_brace}211{r_brace} {alpha}'-Fe diffraction line). In practice, it is important to predict carbon concentration-distance curves under prevailing heat treatment conditions or to conclude conversely from profile measurements. Based on a refined kinetics model of a diffusion-controlled process, part 2 therefore presents a simulation tool developed by means of the finite element method (FEM). Apart from the concentration dependence of the diffusion coefficient, it also considers the decarburisation induced ...
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
Climate change is one of the main global issues of modern time. Ever increasing demand for food/feed and the need for higher environmental standards require shaping of the agricultural activities toward ecological and more sustainable efficient systems. One of the principal ways of attaining higher productivity and environmental standards is identification and adoption of beneficial management practices (BMP) by reviewing the conventional agricultural activities. The BMP are agricultural practices that promote sustainable land stewardship and maintain/increase profitability of farms. The BMP are from both crop and animal production systems and tradeoffs between the two systems could provide several opportunities in reducing, removing and/or avoiding of greenhouse gases (GHG) emissions. Des...
This conference report contains the lectures presented at the BMBF status seminar on the cooperative project ``Bodies of landfills``, which took place at Wuppertal on 25th and 26th April 1995. The cooperative project was started in autumn 1993 and studies the long-term behaviour of wastes deposited at landfills in general. Inorganic and municipal wastes are studied separately. (orig./SR) [Deutsch] Der vorliegende Tagungsband enthaelt die Vortraege des BMBF-Statusseminars zum Verbundvorhaben `Deponiekoerper` vom 25. und 26. April 1995 in Wuppertal. Das Verbundvorhaben `Deponiekoerper` wurde im Herbst 1993 begonnen und befasst sich ganz generell mit dem langfristigen Deponieverhalten von Abfaellen. Es ist unterteilt in die Untersuchung von anorganischen Abfaellen und von Siedlungsabfaellen. (orig./SR)
The aim of this economic study is the wording of a synthetic document for the public information in the framework of the 98/30/CE european directive transposition to the gas internal market. It is writing in four main chapters, one for each country concerned: the Germany, the Spain, the Netherlands and the United Kingdom. Each one presents the historical context, the actors of the natural gas industry and the main provisions. (A.L.B.)
Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...
The replacement of lithium metal from the negative electrode of lithium batteries by a material allowing the reversible insertion of lithium ions is an undeniable commercial success. Carbon electrodes, generally called Li{sub x}C{sub 6}, are the most common type and allow to increase the service life of the battery, its charging fastness and its safety. The safety of such batteries is well known in normal conditions of use, but it has to be known also in any abusive condition of use, whatever is the charging state. The mastery of the phenomena that can occur requires a good knowledge of the kinetics of the exothermal chemical reactions involved. (J.S.) 8 refs.
The ARE progress report discusses the following issues: Economic development and its effects on power supply; Deregulation of the electricity and gas market; Competition between regional utilities; Energy policy of the new German government; European regulations; Legislation on energy supply; Energy supply and cartel law; Regional supply in the East German states. [German] Der Taetigkeitsbericht der ARE befasst sich mit folgenden Themen: Gesamtwirtschaftliche Entwicklung und ihre Auswirkung auf die Energiewirtschaft, Oeffnung des Monopoles fuer Strom und Gas, Wettbewerb der regionalen Energieversorger, Energiepolitik der neuen Bundesregierung, Europaeische Richtlininen, energiewirtschaftsrecht, Versorgungswirtschaft und Kartellrecht und der Regionalversorgung in den neuen Bundeslaendern.