Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to ...
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip ...
This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.
This report gives a brief introduction to the project `Probabilistic Design Tool for Wind Turbines` - PRODETO - which was carried out during the years 1996-98 with partial funding from the European Commission under the Non-Nuclear Energy Programme JOULE III. The report gives an overview of the objectives and motivation for the project, and the methodology used. In this context, an example of reliability-based wind turbine design against fatigue failure is outlined with emphasis on the various important steps herein, which include probabilistic load and resistance modelling, calculation of failure probability, and calibration of partial safety factors for use with a deterministic design code format. The results of the project are presented with emphasis on a developed computer program and its capabilities, and the various elements of an executed case study are outlined. A list of project reports concludes the report. (au)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without ...
In this paper the authors present some final results from a research project focused on introducing automatic control to the operation of cupola iron furnaces. The main aim of this research is to improve the operational efficiency and performance of the cupola furnace, an important foundry process used to melt iron. Previous papers have described the development of appropriate control system architectures for the cupola. In this paper experimental data is used to calibrate the model, which is taken as a first-order multivariable system with time delay. Then relative gain analysis is used to select loop pairings to be used in a multiloop controller. The resulting controller pairs melt rate with blast volume, iron temperature with oxygen addition, and carbon composition with metal-to-coke ratio. Special (nonlinear) filters are used to compute melt rate from actual scale readings of the amount of iron produced and to smooth the temperature measurement. The temperature ...
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and ...
The Structural Aging (SAG) Program is carried out by the Oak Ridge National Laboratory (ORNL) under sponsorship of the United States Nuclear Regulatory Commission (USNRC). The Program has evolved from preliminary studies conducted to evaluate the long-term environmental challenges to light-water reactor safety-related concrete civil structures. An important conclusion of these studies was that a damage methodology, which can provide a quantitative measure of a concrete structure's durability with respect to potential future requirements, needs to be developed. Under the SAG Program, this issue is being addressed through: establishment of a structural materials information center, evaluation of structural component assessment and repair technologies, and development of a quantitative methodology for structural aging determinations. Progress to date of each of these activities is presented as well as future plans. 7 refs., 5 figs.
The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for Testing and ...
Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included
An internal flooding (IF) risk assessment refers to the quantitative probabilistic safety assessment (PSA) treatment of flooding as a result of pipe and tank breaks inside the plants, as well as from other recognized flood sources. The industry consensus standard for Internal Events Probabilistic Risk Assessment (ASME-RA-Sb-2005) includes high-level and supporting technical requirements for developing internal flooding probabilistic risk assessment (IFPRA). This industry standard is endorsed in Regulatory Guide 1.200, Revision 1 as an acceptable approach for addressing the risk contribution from IF events for risk informed applications that require U.S. Nuclear Regulatory commission (NRC) approval. In 2006, EPRI published a draft report for IFPRA that addresses the requirements of the ASME PRA consensus standard and have made efforts to refine and update the final EPRI IFPRA guideline. Westinghouse has performed an IFPRA analysis for several nuclear power plants ...
The Geothermal Energy Association ({open_quotes}GEA{close_quotes}) will create and manage a Geothermal Heat Pump ({open_quotes}GHP{close_quotes}) Training Center to deliver GHP and HVAC courses throughout California in response to imminent demand driven by national promotion. GEA services include providing management structure, cadre, curricula, promotion and physical equipment. The Center is dedicated to infrastructure strengthening goals of the Geothermal Heat Pump Consortium, Inc. ({open_quotes}GHPC{close_quotes}), the California Energy Commission ({open_quotes}CEC{close_quotes}) and Interagency Geothermal Heat Pump Task Force, and Geothermal Energy Association ({open_quotes}GEA{close_quotes}). Second-half 1996 start-up is co-funded by GHPC, CEC, GEA and three California utilities. Initial support is to five utilities representing 70 percent of California power users. Goals include becoming market driven by year No. 3 ...
The diffuse background light in the Coma cluster is measured using isodensity tracings of B, G, V, and R photographic plates taken with the Palomar 1.2-m Schmidt telescope. The isodensity contours are calibrated using the star profile derived by Kormendy (1973). Between 4 and 14 arc min from the center, the surface brightness of the diffuse light decreases from approximately 26 to approximately 28 G magnitudes arc sec"-"2. The total magnitude in this annulus is G = 11.22, which is approximately 45 percent of the light in galaxies alone, or approximately 30 percent of the total. This does little to alleviate the ''missing mass'' problem. The isodensity contours and the equivalent profile of the diffuse light closely parallel the distribution of light in galaxies, implying no strong mass segregation. However, the background light appears to be bluer than the galaxies. This is consistent with the hypothesis that the background consists of stars ...
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)
The Center for Nuclear Waste Regulatory Analyses organized and hosted a workshop on ``Rock Mechanics Issues in Repository Design and Performance Assessment`` on behalf its sponsor the U.S. Nuclear Regulatory Commission (NRC). This workshop was held on September 19- 20, 1994 at the Holiday Inn Crowne Plaza, Rockville, Maryland. The objectives of the workshop were to stimulate exchange of technical information among parties actively investigating rock mechanics issues relevant to the proposed high-level waste repository at Yucca Mountain and identify/confirm rock mechanics issues important to repository design and performance assessment The workshop contained three technical sessions and two panel discussions. The participants included technical and research staffs representing the NRC and the Department of Energy and their contractors, as well as researchers from the academic, commercial, and international technical communities. These ...
This report summarizes the progress made on the development of an integrated multistage fluidized bed retorting process (KENTORT II) during the period of October 1, 1992 through September 30, 1993 under Cooperative Agreement No. DE-FC21-90MC27286 with the Morgantown Energy Technology Center, US Department of Energy. The KENTORT II process includes integral fluidized bed zones for pyrolysis, gasification, and combustion of the oil shale. The purpose of this program is to design and test the KENTORT II process at the 50-lb/hr scale. The PDU was assembled, instrumented and tested during this fiscal year. Along with the major activity of commissioning the 50-lb/hr retort, work was also completed in other areas. Basic studies of the cracking and coking kinetics of model compounds in a fixed bed reactor were continued. Additionally, as part of the effort to investigate niche market applications for KENTORT II-derived products, a study of the ...
France has a wide variety of experimental spent fuels different from LWR spent fuel discharged from commercial reactors. Reprocessing such fuels would thus require the development and construction of special facilities. The French Atomic Energy Commission (CEA) has consequently opted for long-term interim storage of these spent fuels over a period of 50 years. Comparative studies of different storage concepts have been conducted on the basis of safety (mainly containment barriers and cooling), economic, modular design and operating flexibility criteria. These studies have shown that dry storage in a concrete vault cooled by natural convection is the best solution. A research and development program including theoretical investigations and mock-up tests confirmed the feasibility of cooling by natural convection and the validity of design rules applied for fuel storage. A facility called CASCAD was built at the CEA's Cadarache Nuclear Research ...
Rapid growth in economic development, coupled with the absence of an electric grid in large areas of the rural countryside, have created a need for new energy sources both in urban centers and rural areas in China. Environmental pollution from the increased use of coal-fired steam turbines to meet this capacity expansion is a concern. There is a growing interest in China to develop renewable-energy resources and technologies to meet energy demands and help mitigate pollution problems. In February 1995, Secretary Hazel O`Leary of the U.S. Department of Energy signed an Energy Efficiency and Renewable Energy Protocol Agreement with the Chinese State Science and Technology Commission in Beijing, China. Under this agreement, projects using photovoltaics for rural electrification are being conducted in Gansu Province in western China and Inner Mongolia in northern China, providing the basis for much wider deployment and use of photovoltaics for ...
The staff of the Spent Fuel Project Office at the U.S. Nuclear Regulatory Commission undertook the investigation and thermal analysis of the Baltimore tunnel fire event. This event occurred in the Howard Street tunnel, in Baltimore, Maryland, on July 18, 2001. The staff was tasked with assessing the consequences of this event on the transportation of spent nuclear fuel. This paper describes the staff's coordination with the following government and laboratory organizations: the National Transportation Safety Board (NTSB), to determine the details of the train derailment and fire; the National Institute of Standards and Technology (NIST), to quantify the thermal conditions within the tunnel; the Center for Nuclear Waste Regulatory Analysis (CNWRA), to validate the NIST evaluations, and the Pacific Northwest National Laboratory (PNNL), to assist in the thermal analysis. The results of the staff's review and analysis efforts are ...
Concerning the above, it is discussed whether such a system is feasible in Japan. A zinc/air cell system requires some special plants for zinc regeneration, etc. It is necessary to build a zinc refining plant and to install dozens of electrode replacing facilities in an area dozens of kilometers in diameter with the plant at the center. For such a system to be functional, there have to be several tens of thousands of automobile users in a limited area. In Japan, so large a number will not be found anywhere even if the appeal is directed to those in the postal service and electric utilities. There will be no economic success in Japan, different from in Germany. As for the economic comparison between a zinc/air cell system and natural gas system, the two will be equivalent to each other as far as the use of the quick filling stations for the natural gas automobiles remains as it is. When the number in consideration is so large as several tens of thousands, however, ...
ECAL Barrel (EB) As already mentioned in June, the Barrel ECAL is fully commissioned and routinely used during CRUZET runs. Good progress has been made in the last months to ensure a stable and fully reliable operation, in particular for the Trigger path. More details can be found in the DPG report in this bulletin. ECAL Endcaps (EE) In the June CMS bulletin, it had been announced that the Dee’s mechanical assembly had been finished end of May. However the electronics integration was still going on for the first Dee. The Summer has seen a spectacular breakthrough of the Endcap project. The electronics integration of Dee1 was completed early July, and this first Dee was transported to point 5 on July 8th. The completion of the three other Dees followed at a pace of one per week. In all cases the quality of the detector as measured in the assembly center was excellent, with all channels active ...
Following the unexpected, but safely terminated, power and flow oscillations in the LaSalle-2 Boiling Water Reactor (BWR) on March 9, 1988, the Nuclear Regulatory Commission (NRC) Offices of Nuclear Reactor Regulation (NRR) and of Analysis and Evaluation of Operational Data (AEOD) requested that the Office of Nuclear Regulatory Research (RES) carry out BWR stability analyses, centered around fourteen specific questions. Ten of the fourteen questions address BWR stability issues in general and are dealt with in this paper. The other four questions address local, out-of-phase oscillations and matters of instrumentation; they fall outside the scope of the work reported here. It was the purpose of the work documented in this report to answer ten of the fourteen NRC-stipulated questions. Nine questions are answered by analyzing the LaSalle-2 instability and related BWR transients with the BNL Engineering Plant Analyzer (EPA) and by performing an ...
The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)
To obtain reactor physics parameters for high-moderation mixed-oxide (MOX) cores, Nuclear Power Engineering Corporation (NPEC), the French Atomic Commission (CEA), and their industrial partners have conducted a MOX core physics experimental program called MISTRAL with the EOLE critical facility of the Cadarache research center. This program consists of four high-moderation cores and was successfully completed in July 2000. This paper describes the analysis results of MISTRAL-3 that is a homogeneous full MOX cylindrical core (H/HM = 6.2) with an 80-cm height and a 59-cm diameter consisting of 1388 standard pressurized water reactor-type MOX fuel rods of 7.0 wt% plutonium-enrichment in a square pitch of 1.39 cm. NPEC has been analyzing the experimental results by using the SRAC and MVP code systems. SRAC and MVP calculate the nuclear core characteristics correctly for the high-moderation MOX core MISTRAL-3. No apparent trend with the moderation ...
... 4? Program History 5? Center for Advanced Materials and Smart Structures 6? Center for Systems ... Systems 14? Center for Photonic Materials Research 15? Synthesis, Manufacturing and Characterization ...
The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.
In this paper we present some final results from a research project focused on introducing automatic control to the operation of cupola iron furnaces. The main aim of this research is to improve the operational efficiency and performance of the cupola furnace, an important foundry process used to melt iron. Previous papers have described the development of appropriate control system architectures for the cupola. These results are summarized. Then we describe the experimental results obtained with the U.S. Department of Energy Albany Research Center`s research cupola. First, experimental data is used to calibrate the model, which is taken as a first-order multivariable system with time delay. Then relative gain analysis is used to select loop pairings to be used in a multi-loop controller. The resulting controller pairs meltrate with blast volume, iron temperature with oxygen addition, and carbon composition with percent coke. Special ...
This report to the Nuclear Regulatory Commission (NRC) describes the development and application of a methodology to systematically and quantitatively assess predictive uncertainty in groundwater flow and transport modeling that considers the combined impact of hydrogeologic uncertainties associated with the conceptual-mathematical basis of a model, model parameters, and the scenario to which the model is applied. The methodology is based on a n extension of a Maximum Likelihood implementation of Bayesian Model Averaging. Model uncertainty is represented by postulating a discrete set of alternative conceptual models for a site with associated prior model probabilities that reflect a belief about the relative plausibility of each model based on its apparent consistency with available knowledge and data. Posterior model probabilities are computed and parameter uncertainty is estimated by calibrating each model to observed system behavior; prior ...
Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from ...
The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...
The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...
CORAL-I was an experimental, zero-power, fast-spectrum, high-enriched metal uranium reactor that operated from 1968 until 1988 at the former Junta de Energia Nuclear (JEN), CIEMAT at present. The critical measurements performed at the startup of the reactor are being evaluated as part of the International Critical Safety Benchmark Evaluation Program (ICSBEP) and proposed to be included in its 2001 edition. Additionally, the measurement of the mass reactivity coefficient is compared with MCNP4B calculations. This measurement allows one to perform the approach to critical without the need of a previous control rod calibration, thus enhancing the safety of such an approach. This technique can also be applied to other reactor types. CORAL-I (Ref. 1) is a 90% enriched metal uranium reactor domestically designed and manufactured in the experimental facilities of JEN, now CIEMAT, in Madrid, Spain. The enriched uranium was supplied by the International Atomic Energy Agency ...
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available
In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
creating such active galactic nuclei as quasars. Strangely, the center of this fiery whirlpool is offset from the exact center of the galaxy - for a reason that for now remains an...
picture will download the highest resolution version available. In the Center of the Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...
Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with ...
From autumn this year, the FRJ-2 of the Research Center Juelich will be supplying molybdenum targets to the Institut National des Radioelements in Fleurus, Belgium - which deals in medical radio-isotopes worldwide - thus helping to meet the need for technetium-99, which is used in the medical profession for diagnostic purposes because of its favourable radiological characteristics. Technetium-99 is formed as a result of the radioactive decay of molybdenum-99. For many years now, molybdenum has been produced by the irradiation of uranium in research reactors, so that the initiation of molybdenum production in the FRJ-2 is not especially new. What is unusual, however, are the particular peripheral conditions which result from the combination of the irradiation requirements, a predetermined target design and the technical characteristics of the reactor and which necessitated special solutions. This applies especially to the handling of the targets after irradiation, ...
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...
The present thesis presents two different aspects of my work in the L3 experiment, which are on one side the search for supersymmetric particles, the scalar leptons, in two different topologies 'electron + X + E' and '2 leptons + 2 photons + E', each of them being related to two theoretical SUSY models, m-SUGRA and GMSB. On the other side my work has been completed by the study of the BGO crystal electromagnetic calorimeter of L3, and the calibration of the electromagnetic calorimeter EGAP. After the essential motivations being reviewed, the production and disintegration modes are detailed concerning the scalar lepton sector at LEP. Then one presents the analysis techniques which I used to perform my selection, and also the results obtained from the data collected by L3 for center of mass energies between {radical} S =183 GeV and 202 GeV. The selection criteria that allow to isolate the events I looked for, ...
Although the standard model of particle physics agrees perfectly with experimental data, it is unlikely the final theory describing particles and their interactions. New phenomena has been searched in the jets and missing transverse energy topology. Such phenomena may be due to the pair production of leptoquarks decaying into a quark and a neutrino or the pair production of stops decaying into a charm and a neutralino which is assumed to be the lightest supersymmetric particle. These searches have been performed with the Ddiamter detector at hadronic collider TeVatron with a center of mass energy of 1.96 TeV. This kind of searches needs a good understanding of the jet energy calibration. The determination of the relative jet energy scale has allowed us to reduce the systematic uncertainties on the jet energy measurement when comparing the data and the simulation. Moreover a new method has been developed in order to correct simulated jets for ...
The National Oceanic and Atmospheric Administration (NOAA), Department of Defense (DoD), and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation weather and environmental satellite system; the National Polar-orbiting Operational Environmental Satellite System (NPOESS). NPOESS replaces the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA and the Defense Meteorological Satellite Program (DMSP) managed by the DoD. The NPOESS satellites carry a suite of sensors that collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The NPOESS design allows centralized mission management and delivers high quality environmental products to military, civil and scientific users. The ground data processing segment for NPOESS is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence and Information Systems. IDPS processes NPOESS ...
In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to ...
The advantages offered by green roofs range from improvement in architectural and landscape aesthetics to reductions in building energy costs. Seattle Public Utilities (SPU) is encouraging sustainable community development through new policies and regulations that promote green roof installation on public and commercial rooftops in Seattle's urban center. An understanding of climate-specific green roof performance is required in order to develop an accurate representation of the stormwater benefits of green roofs. This paper explored the relative importance of green roofs in storm water management and low impact development (LID) in various areas of Seattle. It also examined the relative effectiveness and applicability of green roofs under various conditions and in various parts of the city compared to other LID strategies such as Seattle's natural drainage systems (NDS) designs, swales and ponds, rain gardens, rainwater harvesting, and porous ...
The Joint Commission on Accreditation of Hospitals (JCAH) has continuously emphasized improvement in the quality of care provided in hospitals as the central purpose of the accreditation process. In...Full Text Available
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judges (AU), the Directors` Decisions (DD), and the Decisions on Petitions for Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission, the Atomic Safety and Licensing Appeal Boards, the Atomic Safety and Licensing Boards, the Administrative Law Judge, the Directors' Decisions, and the Denials of Petitions for Rulemaking.
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions for Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLl), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), The Directors' Decisions (DD), and the Denials of Petitions For Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judges (ALJ), the Directors Decisions (DD), and the Decisions on Petitions for Rulemaking (DPRM).
In Germany, the Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) generally sets maximum workplace concentration values (i.e., a proposed occupational...Full Text Available
Summarizing the three main reasons why customized programs are commissioned, this book explains and explores the key aspects of successful development programs, with views from corporate sponsors, participants, faculty contributors and case studies of customised programs commissioned by 6 organizations
situ by isolating portions of the building envelope and performing tests .MAXIMUM ALLOWED LOAD ...and shall identify commissioning team members who will perform testing and prepare documentation.The commissioning agent may be
The commissioning of four CANDU-600 reactors is discussed, with mention of some design features. The four are Point Lepreau, Gentilly-2, Wolsung and Cordoba reactors. The commissioning of Pickering-5 is also mentioned, and so are some events affecting other CANDU reactors.
The COSA II (computer codes for salt) benchmark problem has been pursued with the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) program code. With the use of this, the code should be validated by means of experimental data and the ability to reproduce real-life calculation results of the KfK (Kernforschungszentrum Karlsruhe/Nuclear Research Center in Karlsruhe) should be proven. A successful validation of the code then forms the foundation stone for the ability to use different calculation problems in the final (ultimate) storage. This also accompanies the consequent reaction of replacing the STEALTH (Solids and Thermal Hydraulics Code for EPRI Adapted from LAGRANGE TOODY and HEMP) program which has a number of program-specific weaknesses compared to the ADINA computer code. In order to reproduce the approximate values from the KfK, the same values have been used. Differences were evident in the discretion and the selection of the initial values for ...
On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB), the U.S. agency responsible for determining the cause of transportation accidents, to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for ...
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving ...
Dual fuel operation, in which natural gas is mixed with the diesel engine intake air and ignition is by diesel fuel spray, has the advantage that engine conversion is simple. Under high load it has the same high efficiency as a diesel engine and it can be switched to normal diesel operation for long distance running. Also, NO{sub x} and black smoke emissions can also be reduced. However, the disadvantages are to increase HC and CO emissions, to reduce efficiency under low load, and to emit the large amount of NO{sub x} under high load. Waseda University was commissioned by Tokyo Gas Co., Ltd. to conduct research program involving experimentation ragarding a dual fuel engine. It was then discovered that the most effective means of solving the problems mentioned above is Exhaust Gas Recirculation (EGR) and that the effect can be increased by heating the intake air. An old engine before the current emission standard was converted to dual fuel operation. It was found ...
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...
This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...
The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...
Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...
... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.
World - USGS visual identity mark and link to main Web site at http://www.usgs.gov/ GEOLOGY OF THE OCOEE WHITEWATER CENTER, CHEROKEE NATIONAL FOREST Ocoee Whitewater Center logo...
... Programmatic Terms and Conditions for the Materials Research Science and Engineering Centers (MRSEC ... NSF Grants Officer. 2. Program Description: Materials Research Science and Engineering Centers ...
will download the highest resolution version available. M51: The Center Of The Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...
Commissioning of a Pressurized heavy water reactor (PHWR) plant of NPCIL involves three phases viz phase-A which consist of pre-criticality activities such as hydro test, air hold test, no load test of motors etc., phase-B consist of criticality and post criticality physics experiments. The phase-C, which is considered the major phase, consist of initial power raise to about 10 % , TG rolling, synchronization, going to significant power in steps and performance tests such as load rejection tests from various power levels. In order to have smooth commissioning for the Phase-C, an integrated team consisting of engineers from various design and analysis groups of NPCIL headquarters was formed to participate along with site O and M engineers, closely observe and coordinate phase-C commissioning activities. During this commissioning some major events and observations took place. An attempt is made to bring ...
A 1976 decision of the US Supreme Court made it clear that the Federal Energy Regulatory Commission (then the Federal Power Commission) has a responsibility to consider and determine allegations that proposed wholesale electric rates create a price squeeze against customers who compete with the wholesaler in making retail electric sales. This article reviews how the commission has approached the matter of discharging its newly recognized responsibility since that time, and describes its current position regarding the several issues and questions that price squeeze allegations raise. 35 references.
29 matches ... 09.20.1999. FOX SPORTS TELEVISION CREW TAPING SEGEMENT IN VISITOR CENTER + More Details. 10.23.2010. USA Science and Engineering Festival ...
Research Center last approximately 1.5 hours and include stops at the Space Weather Prediction Center, ESRL Global Monitoring Division for information on the carbon dioxide...
This is the monthly progress report for the Savannah River Technology Center, which covers the following areas of interest, Tritium, Separation processes, Environmental Issues, and Waste Management.
... Harbor Township Vineland Voorhees Pediatric Partner Hospitals AtlantiCare Regional Medical Center- City Campus, Atlantic City AtlantiCare Regional Medical Center - ...
ObjectiveFamily-centered bedside rounds (FCBR) are recommended to improve trainee education, patient outcomes, and family satisfaction. However, bedside teaching...Full Text Available
... centers in materials research. MRSECs address fundamental materials research topics of intellectual ... in materials research. II. PROGRAM DESCRIPTION MRSECs are supported by NSF to undertake materials ...
The Global Warming International Center (GWIC) is the international body disseminating information on global warming science and policy, serving both governamental, non-governamental ... ...
[Originating_Center='Centro Nacional Patagonico-Laboratorio de Mamiferos Marinos ']. Refine by Category. Please select a field, Projects, Data Centers ...
creating such active galactic nuclei as quasars. Strangely, the center of this fiery whirlpool is offset from the exact center of the galaxy - for a reason that for now remains an...
Pages 184-197: Understanding Personal Change in a Women’s Faith-Based Transitional Center/title link ...titleUnderstanding Personal Change in a Women’s Faith-Based Transitional Center/dc:title
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).
Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
Performance testing and ...Performance testing and commissioning In either an Authority-owned or a dedicated MRF, the Contracting Authority should ...Performance testing is done to demonstrate that the contractor is able to meet the guarantees given
may experience difficulty opening the Facebook page due to current HHS policy and network security that blocks access to the site. Site Map - Contact Us - Linking to USPHS.gov -...
Jul 15, 2004 ... Responding to the recommendations of the President's Commission on Implementation of United States Space Exploration Policy, NASA is teaming ...
On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB, the U.S. agency responsible for determining the cause of transportation accidents), to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for ...
Due to current social and economical framework, in last years many nuclear power plant owners started a program for the Long Term Operation (LTO)/PLIM (Plant Life Management) of their older nuclear facilities. PLIM/PLEX has already been implemented in many countries (USA, Russia, etc.). This process has many nuclear safety implications, other than strategic and political ones. The need for tailoring the available safety assessment tools to such applications has become urgent in recent years and triggered many research actions. In particular, a PLIM framework requires both a detailed review of the features of the main safety programs (Maintenance, ISI, Surveillance) and a complete integration of these programs into the general management system of the plant. New external factors, such as: large use of subcontractors, need for efficient management of spare parts, request for heavy plant refurbishment programs demand for updated techniques in the overall management of the plant. Therefore ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data ...
The perceptual center (P-center) is fundamental to the timing of heterogeneous event sequences, including music and speech. Unfortunately, there is currently no comprehensive and reliable model of P-centers in acoustic events, so P-centers must instead be measured empirically. This study reviews existing measurement methods and evaluates two methods in detail?the rhythm adjustment method and a new method based on the phase correction response (PCR) in a synchronous tapping task. The two methods yielded consistent P-center estimates and showed no evidence of P-center context dependence. The PCR method appears promising because it is accurate and efficient and does not require explicit perceptual judgments. As a secondary result, the magnitude of the PCR is shown to vary systematically with ...
Using the infrared spectroscopy method, we have studied the effect of thermal dehydration (under vacuum and in air) and treatment with water vapor on the acid centers of very high silicon zeolites of the ZSM type. We have shown that dehydration under vacuum and in air completely and irreversibly removes the OH groups at 1120/sup 0/K, while treatment with water vapor removes these groups at 770/sup 0/K. The Lewis acid centers of dehydrated zeolites (represented by two types of centers) are more heat-stable than the Bronsted acid centers, but the vapor treatment at 1020/sup 0/K leads to the disappearance of the Lewis acid centers. In this work, we discuss the reasons for destruction of the acid centers of the zeolites under different treatment conditions.
The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...
The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the station has been commissioned in preparation for commercial service and on the skills that were dedicated to the completion of the project. The paper also deals with some of the features of the CANDU 600 MWe Nuclear Power Plant that make it viable for export.
Public Law 95-209 includes a requirement that the Advisory Committee on Reactor Safeguards submit an annual report to Congress on the safety research program of the Nuclear Regulatory Commission. This report presents the results of the ACRS review and evaluation of the NRC safety research program for Fiscal Year 1983. The report contains a number of comments and recommendations.
Public Law 95-209 includes a requirement that the Advisory Committee on Reactor Safeguards submit an annual report to Congress on the safety research program of the Nuclear Regulatory Commission. This report presents the results of the ACRS review and evaluation of the NRC safety research program for Fiscal Year 1982. The report contains a number of comments and recommendations.
...notice de en es fr it nl European Commission Research Index aeronews All keywords Index feedback The number of documents that contain the keyword aeronews is: 1 EU Transport lsquo;AERONEWSrsquo; -good news for early detection of microdamage European Commission - lsquo;AERONEWSrsquo; -good news for early detection of microdamage ...
...EU Descartes Prizes for excellence in research and science communication descartes, prize, science communication, research, rtd, european commission, ...european union, eu EU Descartes Prizes for excellence in research and science communication Research - EU Descartes Prizes for excellence in research and science ...communication en European Commission Research Descartes Prize Contact | Search ...
This report includes the issuances received during April 1984 from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions for Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions For Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Director's Decisions (DD), and the Denials of Petitions For Rulemaking (DPRM).
This report includes the issuances received during November, 1983, from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions for Rulemaking (DPRM).
This report includes the issuances received during January 1984 from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions for Rulemaking (DPRM).
In November 1998, President Clinton charged the National Bioethics Advisory Commission with the task of conducting a thorough review of the issues associated with human stem cell research, balancing all ethical and medical considerations. The President's ...
The study concludes that while the diversification into nonutility activities by the Rural Electric Cooperatives and the Rural Telephone Cooperatives has been expanding, the regulatory activities by the Rural Electrification Administration and the state public utility commissions have been inadequate to guard against cross-subsidization. In fact, there generally exist no data to identify and investigate illegal cross-subsidization activities of cooperatives. Increasing the regulatory functions of state public utility commissions and the REA was recommended.
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
By opinion and order dated May 20, 2003, Judge Richard K. Eaton of the U.S. Court of International Trade remanded the Commission's (U.S. International Trade Commission) preliminary negative determinations in Blast Furnace Coke from China and Japan for fur...
This forum showcases the work of a variety of different heritage-based centers, organizations, and projects dedicated to research, education, and preservation of tangible and intangible forms of cultural heritage. The descriptions of these centers demonstrate the diversity of heritage work being done today. The centers and projects described in the forum vary in their contexts, missions, and outcomes. Highlighted in the forum are preservation organizations, university-based heritage centers, and a global collaborative cultural heritage project. Each organization in the forum provides information about their missions and goals, their approaches or methods to heritage work, and a brief description of some of their initiatives.
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...
BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...
This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
The group- V vacancy pair, the so-called E-center, has recently been demonstrated to have, both in Si and Ge, more complicated energy-level schemes in the energy gap than were previously assumed. The E-center in silicon has, in addition to its well-established single-acceptor level in the upper half of the band gap, also a donor level in the lower half of the band gap; this donor level has lain hidden for more than 40 years. The E-center in Ge has an even more complicated level scheme as it induces, in addition to two levels analogous to those found in Si, also a double-acceptor level in the upper half of the band gap. Thus the E-center in Si can exist in three charge states and the E-center in Ge in four.
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...
This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...
This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the Commission`s rules, regulatory guides, or ...
It was recognized from the early days of commissioning of Bruce B that Control Maintenance staff would require a level of expertise to be able to maintain Special Safety Systems in proper running order. In the early 80's this was achieved through hands on experience during the original commissioning, troubleshooting and placing of the various systems in service. Control maintenance procedures were developed and implemented as the new systems came available for commissioning, as were operating manuals,training manuals etc. Under the development of the Maintenance Manager, a Conduct of Maintenance section was organized. One of the responsibilities of this section was to develop a series of Maintenance Administrative Procedures (MAPs) that set the standards for maintenance activities including training.
The University of North Carolina Comprehensive Pain Center, which has been in existence since 1972, is a pain evaluation, treatment and research program based upon individual diagnosis, comprehensive...Full Text Available
The National Nuclear Data Center provides information on nuclear reactions, nuclear structure, and decay data, and is a part of the Nuclear Data Center Network, established to coordinate the compilation and dissemination of nuclear data on an international scale.
This quarterly update contains information on the National Bioenergy Center Biochemical Platform Integration Project, R&D progress and related activities.
... materials science and education beyond what is expected from any one Center. "Advanced materials are ... for DMR's Division of Materials Research. "Fundamental research on materials is essential to the ...
Oct 11, 1993 ... Lease: Meadowgreen,3-2.5-2, 2 storyon cuI- ..... also will have the Lunar Landing Training Vehicle elevated over the center of the ...
Jul 5, 2007 ... Search Criteria: Search Field: All > Results : All > Search Term: (Manganese 63) [x]. Sort results by: NASA Center | Date Added to NTRS ...
Features: CHUQUICAMATA, LARGE OPEN PIT MINING OPERATIONS, ROADS, HILLS Center Point Latitude: -22.3 Center Point Longitude: -68.9 (Negative numbers indicate ...
Features: CHUQUICAMATA, LARGE OPEN PIT MINING OPERATIONS, ROADS, HILLS Center Point Latitude: -22.3 Center Point Longitude: -68.9 (Negative numbers indicate ...
The concept of "one-stop information shopping" is becoming a reality at Columbia-Presbyterian Medical Center. Our goal is to provide access from a single workstation to clinical, research, and library...Full Text Available
The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the s...
The CWDD injector has been shipped to Argonne National Laboratory, installed, and recommissioned. Commissioning progress, operational status, and future plans are reported. Operational experience at ANL is compared with that obtained at Culham.
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
... The high resolution imagery , collected over Rio de Janeiro, Brazil, included a mixture of large commercial buildings and private houses, as well as the airport and some community parks. 10/08/11 Read more Top EU R&D companies expect a 5% ...
On 12 July the Audit Commission published For Your Information, a well researched report about information and its management in acute hospitals in Britain, how and why it is failing, and steps that...Full Text Available
This standard provides the general requirements used in the design, construction, testing, and commissioning of concrete containment structures for CANDU nuclear power plants designated as class containment and is directed to the owners, designers, manufacturers, fabricators, and constructors of the concrete components and parts.
Scoping studies have been used across a range of disciplines for a wide variety of purposes. However, their value is increasingly limited by a lack of definition and clarity of purpose. The UK's Service...Full Text Available
After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)
BackgroundWe were commissioned to carry out three health assessments in urban areas of Dublin in Ireland. We required an epidemiologically robust method that could collect data rapidly...Full Text Available
The color centers, which are generated in yttrium-aluminium perovskite (YAP):Nd(1 at.%) and YAP:Er(50 at.%) crystals under the influence of ultraviolet and #gamma#-irradiation, have been studied by absorption spectroscopy. The generated color centers are both stable and transient at room temperature. It is shown that the transient color centers are mainly responsible for the decrease of laser generation efficiency of Nd:YAP and YAP:Er irradiated crystals, although physical mechanisms leading to efficiency decrease are different in these materials. (orig.)
In CsCdBr_3, Tm"3"+ substitutes for Cd"2"+. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm"3"+ ions. (orig.)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power ...
A variety of engineering and experimental applications require primary support structures which are self-centering. High mechanical strength, low-density, carbon fiber/epoxy matrix composite springs are used in unique planar, cylindrical, conical, and spherical configurations to self-center components. The sinusoidal and triangular-shaped composite springs are readily manufactured and assembled into component hardware. Design considerations, flexural strength properties, load bearing and centering data plus procedures for the manufacture of composite springs are presented.
At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.
A first sub-set of the collimation system has been installed for the 2008 first beam commissioning of the LHC. It included 88 collimators around the ring and the two injection lines. Each collimator has two jaws for which must be controlled and monitored with high precision. The LHC collimation system was put into operation from July to October 2008. The installed system is described and first results from system operation without and with beam are presented. It is shown that the LHC collimation system achieved the specified accuracy and reproducibility of jaw positioning. Next steps in collimation commissioning are described and planned system upgrades for high beam intensities are outlined.
Construction and commissioning period of NPP are reduced world over drastically by stringent schedule for financial and economic reasons. For meeting the schedule, commissioning of components and systems are started immediate after installation, while construction activities are continued in parallel at the same place. Parallel activities' and 'Time Constraint' have brought new challenges to 'Management of Fire and Industrial Safely' during commissioning. An innovative approach was used during such phase of commissioning of TAPP-3 and 4. This paper outlines challenges encountered during this phase and special approach and measures used to meet those challenges. This paper also outlines problems encountered during implementation of these measures and subsequent change in approach to ensure smooth and safe execution of activities. Primarily, challenges were conflicting requirements by various agencies to ...
The authors trace the early history of nuclear power regulation in the US. Focusing on the Atomic Energy Commission, they describe the role of other groups that figured in the development of regulatory policies, including the Congressional Joint Committee on Atomic Energy, other federal agencies, state governments, the nuclear industry, and scientific organizations. They consider changes in public perceptions of and attitudes toward atomic energy and the dangers of radiation exposure. The basic purpose of the book is to provide the Nuclear Regulatory Commission and the general public with information on the historical antecedents and background of regulatory issues so that there will be continuity in policy decisions. The book concludes with an annotated bibliography of selected references. 19 figures.
Meet the NCI Expert: Edward Helton (Center for Biome dical Informatics and Information Technology) Orange County Convention Center: NCI Exhibit Booth #500 20110404T140000Z PRODID -//Microsoft Corporation//Outlook 12.0 MIMEDIR//EN 2.0 METHOD PUBLISH X-MS-OLK-FORCEINSPECTOROPEN TRUE PUBLIC CREATED 20110308T204510Z American
This presentation gives an overview of IBM's experience with its approach to usability engineering, User-Centered Design (UCD), which has been introduced nearly one decade ago. It discusses the characteristics of User-Centered Design and the critical factors for successful deployment: - Establishing a culture for usability engineering. - Making User-Centered Design an integral part of the development process. - Multi-disciplinary teams for the design and evaluation of the total user experience. - Building up organizational structures and an infrastructure for methods, tools, communication, and education. - Applying UCD to UCD itself to continuously improve its process and methods. (orig.)
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
The DLTS technique was employed to study deep defect centers in Si doped epitaxial layers of Al_0_._3_7Ga_0_._1_6In_0_._4_7P grown by MOCVD as a part of epitaxial structure GaAs/AlGaInP/GaAs on GaAs substrates. A high concentration of DX centers located in a region near the inverted interface GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P was found. The width of this region with the maximum DX center concentration ranges from 5 to 20 nm. By filling the DX centers in the whole region, the activation energy for electron emission was found to be 0.48 eV. However, it is shown for the first time, that the activation energy of the DX center increases with increasing the distance from the GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P inverted interface. A nonuniform of the DX center concentration on the wafers is also observed. The concentration varies in the range of 1#centre dot#10"1"7 ...
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.
Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...
The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...
Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
In FY-2000, Engineering at Lawrence Livermore National Laboratory faced significant pressures to meet critical project milestones, and immediate demands to facilitate the reassignment of employees as the National Ignition Facility (the 600-TW laser facility being designed and built at Livermore, and one of the largest R&D construction projects in the world) was in the process of re-baselining its plan while executing full-speed its technology development efforts. This drive for change occurred as an unprecedented level of management and program changes were occurring within LLNL. I am pleased to report that we met many key milestones and achieved numerous technological breakthroughs. This report summarizes our efforts to perform feasibility and reduce-to-practice studies, demonstrations, and/or techniques--as structured through our technology centers. Whether using computational engineering to predict how giant structures like suspension bridges will ...
France began atmospheric nuclear testing at Mururoa and Fangataufa atolls in the South Pacific in July 1966. Following international protest, atmospheric testing ceased in August 1970. In late 1995, an International Geomechanical Commission (IGC) was created to assess the short- and long-term effects of underground nuclear testing on the stability and hydrology of Mururoa and Fangataufa. With the aid of its consultants, the Commission sought to develop its own understanding of the mechanics and consequences of the underground nuclear tests. It carried out extensive numerical analyses of shock wave effects, seismic wave propagation, slope stability and pre- and post-test hydrology. However, in its studies, the IGC was constrained to use the data made available to it by the French authorities. The Commission's report (International Geomechanical Commission 1998) has been submitted to the French ...
Since mid-March the Commission on Water Management, with the assistance of the appropriate ministries, visited all regions of the province in order to acquaint themselves first hand with regional water management problems. During the month of June, the Commission also organized a series of ten workshops, attended by a limited number of experts, to explore in depth certain specific questions in the area of water management. During these public sessions the Commission hoped to discuss specifically the specific questions relating to water management problems of First Nations communities, bearing in mind the essential nature of water in maintaining traditional activities. The workshop took place on the Montanard reserve of Mashteuiatsh (Pointe-Bleu). The morning session was devoted to presentations by invited experts, followed by an exchange of views between the experts and the Commissioners, with opportunity for participants ...
This report provides a chronological history of policies and practices relating to the management of radioactive waste for which the US Atomic Energy Commission and its successor agencies, the Energy Research and Development Administration and the Department of Energy, have been responsible since the enactment of the Atomic Energy Act in 1946. The defense programs and capabilities that the Commission inherited in 1947 are briefly described. The Commission undertook a dramatic expansion nationwide of its physical facilities and program capabilities over the five years beginning in 1947. While the nuclear defense activities continued to be a major portion of the Atomic Energy Commission`s program, there was added in 1955 the Atoms for Peace program that spawned a multiplicity of peaceful use applications for nuclear energy, e.g., the civilian nuclear power program and its associated nuclear fuel cycle; a ...
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the ...
The dynamics of a general Bianchi type-IX model with three scale factors is examined. The matter content of the model is assumed to be comoving dust plus a positive cosmological constant. The model presents a critical point of saddle-center-center type in the finite region of phase space. This critical point engenders in the phase space dynamics the topology of stable and unstable four dimensional tubes RxS"3, where R is a saddle direction and S"3 is the manifold of unstable periodic orbits in the center-center sector. A general characteristic of the dynamical flow is an oscillatory mode about orbits of an invariant plane of the dynamics which contains the critical point and a Friedmann-Robertson-Walker (FRW) singularity. We show that a pair of tubes (one stable, one unstable) emerging from the neighborhood of the critical point towards the FRW singularity have homoclinic transversal crossings. The homoclinic intersection manifold has topology ...
The pressurized Heavy Water Reactor (PHWR) consists of horizontal calandria vessel containing a large number of pressure tubes (fuel channels) connected to the reactor inlet and outlet headers by individual feeders. Coolant flow distribution among the pressure tubes play a vital role in extraction of thermal power. For these reactors one of the design objectives is to achieve uniform coolant outlet temperatures by providing coolant flows according to the channel power. This is achieved by the design process known as feeder sizing. This basically consists of accounting for the individual channel power and centre line geometry of individual feeder and iteratively adjusting the feeder hydraulic resistances within the design constraints such as limiting flow velocities, channel flows. Recently, the first unit of 540 MWe i.e Tarapur Atomic Power Project (unit 4) has been commissioned. This paper discusses the verification of the coolant flow distribution in the core ...
The European Commission recently has adopted a new European Strategy for Environment and Health focusing on the growing concern over the adverse health effects caused by environmental pollution. Based on the results of various studies carried out in recent years polychlorinated dioxins and furans (PCDD/Fs) and PCBs are playing an important role in this strategy. In view of the enlargement of the European Union (EU) to include Candidate Countries (CCs) the Commission stressed the need to involve the Candidate Countries from an early stage on in the development of such a strategy. Thus two studies have been commissioned which are particularly directed to provide a) an overview on environmental levels and human exposure of dioxins and PCBs and b) an harmonised PCDD/F emission inventory for the target matrices air, water and land The latter study, entitled ''Dioxin Emissions in Candidate ...
The interferometric gravitational wave detector Virgo has successfully completed the first major step of its commissioning. It consists of a Michelson interferometer with 6 m arms with suspended mirrors. The interferometer is tuned to the dark fringe with a recycling mirror on the other port (bright fringe) to form an equivalent 12 m long Fabry-Perot cavity. This setup has allowed us to validate the major technology choices that have been made: passive seismic attenuators, a light source with a long mode cleaner, many analogue and digital servo loops, control software, high speed data acquisition system. A sensitivity of 8 x 10"-"1"7 m Hz"-"1"/"2 at 1 kHz together with a duty cycle of 80% has been attained during a 72 h engineering run. The data analysis allowed us to understand the noise contributions, and several improvements have been carried out while proceeding with the end of the installation of vacuum tubes and the remaining suspensions, and before starting ...
Traditionally, the Federal Energy Regulatory Commission has implemented its statutory requirement that wholesale electric rates be just and reasonable by comparing a seller's proposed rates to its own cost of service. In the last four years, 40 requests for market-based prices have opened up an alternate path for just and reasonable rates. The common characteristic of these 40 requests is that the price is not tied directly to the seller's own costs but rather to market conditions. To date, the Commission has approved 28 of these requests and rejected eight. Four are pending. In this paper the authors assess what has happened, and describe the common standards that have been developed on a case-by-case basis in the last four years. In particular, they examine how these standards have been applied in cases involving affiliates of traditional utilities. Finally, they discuss some of the unresolved issues and possible ...
BHP Petroleum (BHPP) has now operated the 164 tonne per day Methanol Research Plant (MRP) located on the outskirts of Melbourne, Australia for over one year. This plant was commissioned in 1994 making first methanol on 17th October and has operated since then, selling product by pipeline to two local customers, ICI Adhesives and Borden Australia. The plant is based on the Leading Concept Methanol technology (LCM) licensed from ICI Katalco. Since 1985 BHPP has been involved in the development of Floating Production Storage and Offloading (FPSO) technology for the production of oil and gas offshore. In order to utilize the gas associated with oil on remote offshore oil production facilities the combination of gas conversion to methanol and existing FPSO technology is being investigated. The LCM technology being commercialized at the MRP is part of the strategy to demonstrate and develop LCM technology such that it could be located on the deck of a floating vessel in ...
Electric utilities are actively seeking ways of optimizing the economics of their operations by improving productivity and reducing time and money spent on maintenance. Iberdrola, a Spanish utility, is using advanced machine condition-monitoring technology to centralize control and maintenance of its hydropower projects as a means of achieving those goals. The company is using a blend of technologies to supervise their projects from a regional control center. The monitoring scheme makes use of data from on-line, machine-condition monitors, displays from in-plant audio asnd video equipment, and analysis from the control center`s SCADA system.
Several possibilities of the use of molecular models in quantum-chemical investigations of the structure of defect centers on the surfaces of oxides on nontransition elements have been illustrated. There has been a special discussion of the assumption of the local nature of the chemical interactions in these systems, which underlies such an approach, and of the consequent laws governing the formation of their lattices in the example cases of zeolites, kaolinites, and comparable boron- and aluminum-containing oxides. A quantum-chemical interpretation of the body of experimental data from investigations of the dehydroxylation of H forms of zeolites has been given. The structure of the Lewis acid centers formed as a result, and their chemisorption properties, have been discussed.
This paper obtains the acidity spectra of modernites and SVK-zeolites from the heats of adsorption of NH/sub 3/ at 300 C and compares the catalytic activity of these zeolites with the cracking of n-octane and the isomerization of o-xylene. It is shown that the calculation of the specific catalytic activity of centers of different strengths by the method of regional rates allows one to predict the activity of the zeolites from the acidity spectra. It follows from the calculation that only the centers of Bronsted acidity are active towards cracking but that the centers of Lewis acidity are also active towards isomerization.
CRE is the French commission for energy regulation. CRE's remit is to assist in ensuring the proper operation of the electricity and natural gas markets for the benefit of the end-user. In particular, CRE ensures that the conditions of access to electricity and natural gas transmission and distribution systems do not hinder the development of competition. It monitors, for the electricity and natural gas sectors, all transactions made between suppliers, traders and producers, all transactions made on the organised markets and cross-border trading. It ensures that suppliers, traders and producers propose offers that are consistent with their financial and technical constraints. It monitors the implementation of and compliance with regulations giving consumers the right to choose their supplier in a competitive market, and allowing new suppliers to enter the market. This document is the 2008 activity report of CRE. Content: A - How CRE works: CRE regulatory ...
Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and inconsistent. Methodologies were developed to identify the problem and ...
Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...
Engine flow simulation was provided by four separately mounted air ejectors connected to a high-pressure air supply. The engine nacelle center lines were ...
Challenges of robotic cars, sponsored by the Defense Advanced Research Projects Agency (DARPA) of the U.S. Defense Department. Carroll Cordes, recently retired USGS branch chief,...
The results of this research centered on the experimental studies of a single superconducting persistent current qubit, the implementation of type-II algorithms using these qubits, and the proposal for adiabatic quantum computing using these qubits. The m...
Nat'l Training Center Contact Us Directory Email Us BLM > Socioeconomic Impacts > Timber Print Page Socioeconomic Impacts from Timber BLM-administered lands yielded $337...
Lead is known to enter substitutionally in divalent state when doped in alkali halides. When irradiated at room temperature these lead centers (Pb"+"+) act as traps for electrons knocked off from the halogen ions and become Pb"+ and Pb"0 (for large doses of irradiation). These changes could be followed in the optical absorption studies. These lead-doped crystals after X-ray irradiation yield a thermoluminescence output smaller than that observed in 'pure' crystals. However, two new glow peaks are observed in additions to those due to F-centers. In KCl : Pb and Kbr : Pb crystals part of the F-center glow preceds the new glow peaks. The new peaks are attributed to the Pb"+ and Pb"0 centers. The glow peak temperatures and trap depths for these peaks an obtained by total-curve fitting method are reported. (author).
... Astronomy & Space Biology Chemistry & Materials Computing Earth & Environment Education ... Materials Research Center at the University of Chicago, one of nearly 30 NSF-supported Materials ...
Education resources dealing with solar-terrestrial physics, solar effects, solar radiation, etc. Includes links to short reference papers on subjects ... ...
ROBOT-ASSISTED RADICAL LAPAROSCOPIC PROSTATECTOMY WAKE FOREST UNIVERSITY BAPTIST MEDICAL CENTER WINSTON-SALEM, NC 00:00:08 ANTHONY ATALA, MD: I would like ...
... The study cohort consisted of 2,123 military working dogs that were ... maintained at the Department of Defense Military Working Dog Training Center ...
This paper summarizes the main features of four current REDD proposals: Compensated Reduction, Papua New Guinea et al; Joint Research Center; and Brazil. ... ...
Sep 12, 1975 ... POCKET CALCULATORS. Jose P. Olivares 35, Robert B. Clowns and ... of pocket calculators and has an- Washington to arrive by Nov. 20. ...
Sep 5, 2008 ... Russia. The six-component balance for blunt models aerodynamic force measurement in shock tunnel. Lu Zhiquo, Liu Hongshan, Zhang Yan ...
Oct 30, 2006 ... Pigment Analysis by HPLC at Horn Point Laboratory. Laurie Van Heukelem. Crystal Thomas. Meg Maddox. University of Maryland Center for ...
Background Trauma centers are designated to provide systematized multidisciplinary care to injured patients. Effective trauma systems reduce patient mortality by facilitating the treatment of injured patients at appropriately resourced hospitals. Several U.S. studies report reduced mortality among patients admitted directly to a level I trauma center compared with those admitted to hospitals with less resources. It has yet to be shown whether there is an outcome benefit associated with the ?level of hospital? initially treating severely injured trauma patients in Australia. This study was designed to determine whether the level of trauma center providing treatment impacts mortality and/or hospital length of stay. Methods Outcomes were evaluated for severely injured trauma patients with an ...
Data on French nuclear electricity generation sites, nuclear power plant operations personnel, operation simulators, nuclear training centers and training statistics are presented.
Like few other organs, the skin is continuously exposed to multiple exogenous and endogenous stressors. Superimposed on this is the impact of psychological stress on skin physiology and pathology....Full Text Available
operations and defense, personnel misconduct (PM), law enforcement (LE), and counterintelligence (CI) investigations.- At any time, the USG may inspect and seize data stored on...
and the Wildland Firefighter Foundation. To request a marker click here. Engraved bricks may also be purchased from the Foundation to become part of the site. To request a...
Co-op students hired since December 3, 1983 will be covered under FERS. ... amount of sick leave that can be accumulated for use in succeeding years. 11. ...
of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...
A waterjet coating-removal system was developed at NASA's Marshall Space Flight Center in Huntsville, Ala., to remove thermal protective coatings from the ...
Jul 7, 2008 ... HOUSTON -- Following a detailed, integrated assessment, NASA selected ... in the center that provides a 360-degree view around the station. ...
Jun 21, 2006 ... The competition is organized by the Marine Advanced Technology Education Center (MATE) and Marine Technology Society's (MTS) ROV Committee. ...
star formation. To either side of the center, a small bar of dust and gas is helping to fuel the new stars. NASA's Jet Propulsion Laboratory, Pasadena, Calif., manages the...
The Bantam System Technology Project is one element of the Advanced Space Transportation Program -- a NASA initiative to reduce the cost of space launch and ...
In CsCdBr{sub 3}, Tm{sup 3+} substitutes for Cd{sup 2+}. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm{sup 3+} ions. (orig.) 22 refs.
... of China Lake Naval Weapons Center, California. ... Figure 4: The Space-Based Laser cleaning ... of Aeronautics and Astronautics (AIAA) Space 2001 ...
A new supersymmetric gauge-invariant model is proposed. It is shown that the hidden-symmetry algebra for this model is the Kac-Moody algebra without a center.
MD, Chief, Division of Endocrinology, Diabetes and Metabolism, Trinitas Regional Medical Center, Elizabeth, NJ. Review provided by VeriMed Healthcare Network. Also reviewed...
indicate incipient flow separation. The peak stagnation line ...... culations of Transonic Fan Performance, AGARD Propul- sion and Energetics Symposium on ...
By W. Wayne Scott. Langley Research Center. SUMMARY. Thin- and thick-target bremsstrahlung spectra are presented for electron energies up to 7.0 MeV. ...
and audio technology. The exhibition will travel to muse- ums and science centers in several U.S. cities over the next 5 years. Back in the classroom, ...
be due to flow separation and reattachment, rather than transition. The analysis predicted a .... lations of Transonic Fan Performance," AGARD Propulsion ...
To study the defect creation induced by electronic processes in refractory oxides, MgO single crystals were irradiated with high energy tin, uranium and lead ions. Optical absorption measurements showed that F-type centers (oxygen vacancies with trapped electrons) were created during irradiation. The total number of centers per unit area of bombarded sample increases linearly with irradiating fluence. The main part of the point defects was found to arise from electronic processes. The concentration of F-type centers induced by ionization increases with the electronic energy losses. Assuming a saturation of point defect concentration at high fluences, F-type center creation cross sections could be estimated. The influence of irradiation temperature and of the velocity of the bombarding ions are discussed.
diet and genetic obesity metabolic defects and inflammation. To determine the role of adipocyte death in promoting adipose tissue inflammation and insulin resistance in animal...
... Uninterrupted access to and use of critical infrastructure in the Arabian Gulf region are key to the successful prosecution of the Global War on Terror ...
CESAREAN SECTION SHAWNEE MISSION MEDICAL CENTER MERRIAM, KANSAS March 13, 2008 00:00:09 ANNOUNCER: Tonight you will experience the miracle of birth during ...
CESAREAN SECTION SHAWNEE MISSION MEDICAL CENTER MERRIAM, KANSAS March 13, 2008 00:00:09 ANNOUNCER: Tonight you will experience the miracle of birth during a live ...
evaluation, novelty detection, resource discovery, interfaces and visualization, digital libraries, computational social science, and cross-lingual information retrieval. The CIIR...
... a Networked Embedded Sensing Toolkit (MSR Sense ... edging due to mis-registration than the ... Langrebe, Signal theory in multisensor remote sensing ...
During instrumentation of the root canal, it is important to develop a continuously tapered form and to maintain the original shape and position of the apical foramen. However, the presence of curvatures...Full Text Available
respectively. This is a NASA and GSFC requirement to help ensure our computer and network security on center. In the near future, ftp access, with the exception of anonymous ftp of...
who was appointed in July to lead the Defense Advanced Research Projects Agency, or DARPA, made visits last week to UC Berkeley, Stanford, UCLA and the California Institute of...
Aug 6, 2009 ... be cleaned with common household disinfectants regularly and after increased crowd contact. Marshall's Emergency Operations Center and the ...
Barlow, Nadine Northern Arizona University, Flagstaff, AZ. 10. Barker, Don NASA Johnson Space Center, TX. 11. Beaty, David NASA Jet Propulsion Laboratory, ...
The NASA Langley Distributed Active Archive Center archives and distributes data relating to Radiation Budget, Clouds, Aerosols, and Troposheric Chemistry.
Information search in a distributed environment is an interactive process between the user and the artifact. How the information is distributed across the user and the artifact determines the efficacy...Full Text Available
We advance a tentative composite model for computer security at JPL, together with inter and intra networking with other NASA centers and overseas clients.
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW)
The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW).
The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary excretion patterns for different physicochemical forms of uranium. The ...
This third Missouri River Basin Commission report on Status of Electric Power in the Missouri River Basin provides information on the status of electric power generation, future needs, and potentials for meeting these needs. Information for this 1980 update is based upon available published information up to and including December 31, 1979. State and federal members of the Missouri River Basin Commission provided information for sections of the report and on legislative activities. Information is included on the planning and projected costs of hydro, nuclear and fossil-fuel power plants, pumped-storage plants, transmission systems, projected power demands, the environmental, socio-economic-cultural impacts of electric power generation, and regulations affecting energy development. (LCL)
This is the seventh report by the Advisory Committee on Reactor Safeguards (ACRS) in response to the Congressional requirement for an annual report on the Nuclear Regulatory Commission (NRC) Reactor Safety Research Program. As previously requested by the Congress, the timing of this report has been adjusted to enable the ACRS to address the proposed budget for FY 1985 that has been submitted to the Congress by the President. Part I is a compilation of our comments and recommendations regarding the NRC Safety Research Program budget for FY 1985. It is intended to serve as an Executive Summary. Part II is divided into eight chapters, each of which represents a Decision Unit of the NRC research program. In each chapter, specific comments are included on the research involved in the Decision Unit, an assessment of priorities, and recommendations regarding new directions and levels of funding.
This is the sixth report by the Advisory Committee on Reactor Safeguards (ACRS) that has been prepared in response to the Congressional requirement for an annual report on the Nuclear Regulatory Commission (NRC) Reactor Safety Research Program. Part I is a compilation of our general comments and recommendations regarding the NRC Safety Research Program, and includes budget recommendations and an identification of matters of special importance that deserve increased emphasis. It is intended to serve as an Executive Summary. Part II is divided into ten chapters, each of which represents a Decision Unit of the NRC research program. In each chapter, specific comments are included on the research involved in the Decision Unit, an assessment of priorities, and recommendations regarding new directions and levels of funding.
In 2009, following approval of the European Marine Strategy Framework Directive (MSFD, 2008/56/EC), the European Commission (EC) created task groups to develop guidance for eleven quality descriptors that form the basis for evaluating ecosystem function. The objective was to provide European countries with practical guidelines for implementing the MSFD, and to produce a Commission Decision that encapsulated key points of the work in a legal framework. This paper presents a review of work carried out by the eutrophication task group, and reports our main findings to the scientific community. On the basis of an operational, management-oriented definition, we discuss the main methodologies that could be used for coastal and marine eutrophication assessment. Emphasis is placed on integrated ap...
This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the Commission's rules, regulatory ...
Digests and indexes for issuances of the Commission (CLI), the Atomic Safety and Licensing Board Panel (LBP), the Administrative Law Judges (ALJ), the Directors` Decisions (DD), and the Decision on Petitions for Rulemaking (DPRM) are presented in this document. These digests and indexes are intended to serve as a guide to the issuances. Information elements common to the cases heard and ruled upon are: case name (owner(s) of facility); full text reference (volume and pagination); issuance number; issues raised by apellants; legal citations (cases, regulations, and statutes); name of facility, docket number; subject matter of issues and/or rulings; type of hearing (operating license, operating license amendment, etc.); type of issuance (memorandum, order, decision, etc.).
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of Sizewell B. A specific example is ...
At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The experience on the ...
Digital libraries continue to flourish. At the same time, the principles of user-centered design and the practice of usability testing have been growing in popularity, spreading their influence into the library sphere. This article explores the confluence of these two trends by surveying the current literature on usability studies of digital libraries. This article focuses on the methodology of studies of multimedia digital libraries. (Contains 1 table and 45 notes.)
...Resort and Convention Center, National Harbor, Maryland, USA September 18-20, 2011 XX HELSINKI DRUG RESEARCH CONGRESS Helsinki, Finland October 23-27, 2011 2011 AAPS Annual Meeting and Exposition Washington Convention Center Washington, DC June 26-29 2012 10th International Symposium on Pharmaceutical Sciences Ankara, Turkey Printer-friendly version Home | Elsevier ...
... Research Center, Washington DC May 23 BBC NEws: US used Nuclear Weapons in Afghanistan Jalalabad: New reference levels based on recent samples show uranium levels 45 times normal. New bioassay studies identify uranium internal contamination in Spin Gar (Tora Bora) area and the City ...
... Studies People Projects Opportunities Framework Critical Sectors Development Goals Geographic Region Geographic Scale Research Themes Printer-Friendly Center for Ocean Solutions Early Career Fellowship Program Location: Stanford, California Source: The Center for Ocean Solutions (“Ocean Solutions”) seeks one or more recent graduates who have received a JD, MBA or PhD in the natural, physical or social sciences in the last five years, and who ...
CEA is a public body devoted to technological research with 9 research centers throughout France. The activities of its 16,000 scientists, engineers, and technicians deal with new technologies for nuclear energy and alternative energies (fuel batteries, solar energy, energy storage) as well as technologies related to the new economy, in particular in the fields of microelectronics, bio-technologies, and materials. (author)
This report summarizes activities of the Amarillo National Resource Center for Plutonium during the quarter. The report describes the Electronic Resource Library; DOE support activities; current and future environmental health and safety programs; pollution prevention and pollution avoidance; communication, education, training, and community involvement programs; and nuclear and other material studies, including plutonium storage and disposition studies.
Programs in coal research by the Pittsburgh Energy Technology Center are discussed. Topics include: Coal Science and Chemistry, Coal Liquefaction, Alternative Fuels, Coal Preparation, Combustion, MHD Program, Flue Gas Cleanup, Environmental Coordination, and Technology Transfer. (CBS)
This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.
This is the sixth book on reactor materials published under sponsorship of the Naval Reactors Office of the United States Department of Energy, formerly the United States Atomic Energy Commission. This book presents a comprehensive compilation of the most significant properties of thorium dioxide, much like the book Uranium Dioxide: Properties and Nuclear Applications presented information on the fuel material used in the Shippingport Pressurized Water Reactor core.
The NuMI beam at Fermilab has delivered over 5 x 10{sup 20} 120 GeV protons to the neutrino production target since the start for MINOS [1] neutrino oscillation experiment operation in 2005. We report on proton beam commissioning and operation status, including successes and challenges with this beam.
Description is given of how the design challenges were met in commissioning the Sasol Two plant in 1980, a larger plant than Sasol One, and devoted to producing liquid fuels. The design parameters included treating South African coals of poor quality with high ash contents, and rapidity in building the plant.
Changes to SEER Data Set for 2003 SEER Program Code Manual, 3rd Edition, 1st revision Data Items Required by SEER but No Longer Collected by COC The following fields will still be required by SEER or its participating central registries, even though they will no longer be collected by Commission on Cancer-approved facilities.
The report is an overview on the production of the nuclear energy all over the world. The amount of production at present and in future, availability of the nuclear fuel, development of nuclear technology, environmental and safety issues, radioactive waste management and commissioning of the plants and also the competitivity of nuclear energy compared with other energy forms are considered. (91 refs.).
In 1991 the Federal Energy Regulatory Commission (FERC) continued it efforts to restructure the electric utility industry, emphasizing market-based pricing of wholesale power transactions and transmission access and pricing. Other issues covered in this report include pricing and policy initiatives, filing procedures, the generic rate of return on common equity, the price squeeze, contract interpretation, and legislative developments.
Appendix B to 10 CFR Part 50 establishes overall quality assurance requirements for the design, construction and operation of safety-related structures, systems, and components. This guide presents a method acceptable to the Commission for complying with these regulations with regard to overall quality assurance program requirements during design and construction of nuclear power plants. Input to this guide has been provided by the Advisory Committee on Reactor Safeguards.
The Tevatron Run 2 has begun. The Tevatron program in the next six years offers a real opportunity to significantly advance our understanding of the fundamental properties of the universe. It is an exciting, challenging program that goes straight to the highest priorities of high energy physics worldwide. The accelerator and detectors are being commissioned and seem to be performing well. We anticipate first physics results in the summer of 2002.
The Commission of the European Communities has submitted a directive for the protection against microwaves. According to this directive, exposures above the upper limit established for the protection of individuals and the general population are permissible only if the respective individuals are required to submit to occupational medical control. An introductory overview is presented giving information on microwaves, applied techniques and available protective means.
Norad commissioned Econ Poeyry to map teaching and research activities and capacity related to clean energy in selected Ethiopian universities. The mapping identified challenges and opportunities with the aim of facilitating future intervention by the Ethiopian Government and donors to help improve the energy sector development of the country. The report covered the government-owned universities of Bahir Dar, Mekelle, Jimma, Arba Minch and Addis Ababa. The mapping was based on a questionnaire and on interviews at each university. (Author)
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
To meet growth in the fast developing Pearl River Delta economic zone in China`s Guangdong province, a 270 MW oil-fired combined cycle at Foshan was built and commissioned in only 22 months from financial closure. This article describes the Foshan power station, specifications, design, procurement, construction and operating concerns. 5 figs.
In an effort to accelerate deployment of Distributed Energy Resources (DER) such as wind, solar, and conventional backup generators to our nation's electrical grid, Northern Power Systems (NPS), the California Energy Commission (CEC), and the National Renewable Energy Laboratory (NREL) collaborated to create a prototype universal interconnect device called the DER Switch.
...htm Waste Framework Directive 75/442/EEC (amended by Directive 91/156/EEC) and Waste Management Planning http://ec.europa.eu/environment/waste/plans/index.htm Selected EC commissioned/supported projects including LCA IPP Pilot Product exercise on mobile phones and on tropical garden furniture http://ec.europa.eu/environment/ipp/pilot.htm \\
The Department of Energy has used its seldom-used statutory authority and filed comments with the Federal Energy Regulatory Commission urging support for Public Service Company of Indiana's request that the FERC allow it to sell up to 450 megawatts of firm power to eligible wholesale purchasers at negotiated or market-based rates in exchange for open transmission access for other generators.
DescriptionCEH - Quest CCMAP see http://quest.bris.ac.uk/research/themes/CCMAP.html CCMAP (Climate-carbon modelling, assimilation and prediction) Leader: Dr. Eleanor Blyth (CEH, Wallingford) Overview and Goals CCMAP is one of QUEST's Theme 1 projects and is about to be commissioned to the Centre for Ecology and Hydrology at Wallingford. The Principal Investigator will be Dr. Eleanor Blyth, with subcontracts to the Universities of Bristol (Dr. Wolfgang Knorr, Earth Sciences and QUEST; Andy Ridgw [continued...
A consortium of four institutions, based at Western Michigan University, was to plan a Research and Development Center on Student Testing, Evaluation, and Standards Setting. The four consortium sites are Boston College, the Dallas Independent School District, the University of Kansas, and Western Michigan University. This report is a final performance report for the planning grant made to Western Michigan University by the National Institute of Education. The first section provides a summary of the planning activities actually conducted under the grant. It includes a description of particular problems and successes, a list of participants and their affiliations, and an evaluation report for the planning project. The second section is a technical report on the Research and Development (R and D) mission for the Center. It updates the mission and strategy statement contained in the planning grant application and includes an agenda, with ...
Material related to routine as well as sensitive aspects of parent/day care center relationships is presented in this training module, one of a series providing staff development information for programs operated for dependents of military personnel. The module offers a brief discussion of ways caregivers can help parents feel at ease about leaving their children in child care and presents a set of multiple-choice skill-building exercises for effectively working with parents. Exercises focus on various topics, including how parents can be approached when their child may have a health problem, when child abuse or neglect is suspected, and when parental cooperation is needed to stop a child's undesirable or disruptive behavior. Exercises are also devoted to the questions of whether or not caregivers should act as advisors to parents or tell parents about their child's behavior at the center. Concluding exercises indicate how caregivers can ...
This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and ...
This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and the ...
This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional ...
This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional ...
Court decisions available so far do not primarily consider the problems linked to the commissioning of an expert and his mandate, as well as the legal status of the commissioning of an expert as an administrative act which might be legally contestable. Thus there are at present no court decisions that would create legal certainty in matters of the act of commissioning a nuclear expert opinion. The current legal situation is such that an independent order for commissioning of an expert opinion in compliance with section 19 III AtG (Atomic Energy Act), which in general is given in response to the refusal of the facility operator to do so, can be independently contested on the basis of section 44 a, sentence 2 VwGO (Rules of Administrative Courts). The current practice of conflict-oriented, or nuclear power phase-out-oriented, implementation of the nuclear law poses a threat to our constitutional state and ...
Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...
In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0
The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...
Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...
Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.
Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...
Amorphous materials in the system xLi{sub 2}S{center_dot}(100-x)SiS{sub 2}, where x ranged from 50 to 70 mol %, and (100-y) (0.6Li{sub 2}S{center_dot}0.4SiS{sub 2}){center_dot}yLi{sub 4}SiO{sub 4}, where y ranged from 0 to 10 mol %, were synthesized by mechanical milling of crystalline starting materials, Li{sub 2}S, SiS{sub 2} and Li{sub 4}SiO{sub 4}. At the compositions with large amounts of Li{sup +} ions, a part of crystalline Li{sub 2}S used as a starting material remained in the milled powder samples. It was found that the milled powder samples in both systems obtained by mechanical milling exhibited high conductivities in the order of 10{sup -4}S{center_dot}cm{sup -1} at room temperature in spite of the presence of small amounts of Li{sub 2}S crystals. The conductivity values of the pelletized samples of xLi{sub 2}S{center_dot}(100-x)SiS{sub 2} powders maximized at the ...
This Environmental Assessment (EA) reviews the environmental consequences associated with the proposed action of granting a site use permit to construct and operate a conference center on an approximately 70-acre tract of land on the Savannah River Site (SRS). While the proposed action requires an administrative decision by DOE, this EA reviews the linked action of physically constructing and operating a conference center. The SRS is a DOE-owned nuclear production facility encompassing approximately 200,000 acres in southwestern South Carolina. The proposed conference center would have an area of approximately 4,000 square feet, and would infrequently accommodate as many as 150 people, with the average being about 20 people per day. In addition to the No-Action alternative, under which the Research Foundation would not require the 70-acre tract of SRS land for a conference center, this EA considers site ...
Lawrence Livermore National Laboratory's Engineering Directorate has two primary discretionary avenues for its investment in technologies: the Laboratory Directed Research and Development (LDRD) program and the ''Tech Base'' program. This volume summarizes progress on the projects funded for technology-base efforts in FY2004. The Engineering Technical Reports exemplify Engineering's more than 50-year history of researching and developing (LDRD), and reducing to practice (technology-base) the engineering technologies needed to support the Laboratory's missions. Engineering has been a partner in every major program and project at the Laboratory throughout its existence, and has prepared for this role with a skilled workforce and technical resources. This accomplishment is well summarized by Engineering's mission: ''Enable program success today and ensure the Laboratory's vitality ...
Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.
In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.
The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.
The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
Post-tensioned (PT) self-centering moment frames have been developed as an alternative to typical moment-resisting frames (MRFs) for earthquake resistance. When a PT frame deforms laterally, gaps between the beams and columns open. However, the gaps are constrained by the columns and the slab in a real PT self-centering building frame. This paper presents a methodology for evaluating the column restraint and beam compression force based on the column deformation and gap openings at all stories. The method is verified by cyclic tests of a full-scale, two-bay by one-story PT frame. Moreover, a sliding slab is proposed to minimize restraints on the expansion of the PT frame. Shaking table tests were conducted on a reduced-scale, two-by-two bay one-story specimen, which comprises one PT frame ...
This final scientific report documents the Industrial Technology Program (ITP) Stage 2 Concept Development effort on Data Center Energy Reduction and Management Through Real-Time Optimal Control (RTOC). Society is becoming increasingly dependent on information technology systems, driving exponential growth in demand for data center processing and an insatiable appetite for energy. David Raths noted, 'A 50,000-square-foot data center uses approximately 4 megawatts of power, or the equivalent of 57 barrels of oil a day1.' The problem has become so severe that in some cases, users are giving up raw performance for a better balance between performance and energy efficiency. Historically, power systems for data centers were crudely sized to meet maximum demand. Since many servers operate at 60%-90% of maximum power while only utilizing an average of 5% to 15% of their capability, there are ...
Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.
The introduction of numerical control (NC) machine tools has made it possible to automate machining in series and small series production. The organization of automated production sections merged NC machine tools with automated transport systems. However, both the one and the other require the presence of an operative at the machine for low skilled operations. Industrial robots perform a number of auxiliary operations, such as equipment loading-unloading and control, changing cutting and auxiliary tools, controlling workpieces and parts, and cleaning of location surfaces. When used with a group of equipment they perform transfer operations between the machine tools. Industrial robots eliminate the need for workers to form auxiliary operations. This underscores the importance of developing robotized manufacturing centers providing for minimal human participation in production and creating conditions for two and three shift operation of equipment. Work carried out at ...
Southern California Gas Co.`s (SoCalGas) Energy Resource Center (ERC) in Downey, Calif. is a 45,000 ft{sup 2} (4,181 m{sup 21}) conference and education center created to help energy decision-makers find the most energy-efficient, cost-effective and environment-sensitive solutions to their energy requirements. The center has 36,000 ft{sup 2} (3,344 m{sup 2}) of remodeled space and 9,000 ft{sup 2} (836 m{sup 2}) of new space, all designed to showcase the latest energy-efficient and environment-sensitive technologies. The building is one of the 25 buildings in the US to be designated as Energy Star Showcase buildings by the US Environmental Protection Agency.
Bioethics--the study of ethical issues in science and medicine--has grown to become a significant academic and service-oriented discipline with its own research centers, conferences, journals, and degree programs. As these issues have moved to the center of public debate, the law has assumed an increasingly important place in the discipline of bioethics. Today, embryonic stem cell research stands out as a critically important issue about which the U.S. has neither ethical consensus nor clear, comprehensive regulation. The ethical debate centers on the fact that stem cell research involves the destruction of very early human embryos. This article provides a brief scientific background followed by a discussion of key ethical and legal/regulatory issues that surround embryonic stem cell research.
This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
The study examines the question of whether or not civilian marketing practices and principles can be applied in the military care setting. Using the NRMC Great Lakes as a basis, the answer is yes--consumers of military medical care are ready to be the rec...
The effects of response effort on safe behaviors (i.e., glove wearing, hand sanitizing, and electrical outlet replacement) exhibited by therapists at an autism treatment center were examined. Participants...Full Text Available
NASA needed a way to safely strip old paint and thermal protection material from reusable components from the Space Shuttle; to meet this requirement, Marshall Space Flight Center teamed with United Technologies' USBI Company and developed a stripping sys...
Oct 28, 2009 ... Note: FERS employees become eligible for disability retirement after 18 ... Can I use advanced sick leave while I am on the Voluntary Leave ...
... York, 7/15/2008) Cancers Adrenal Gland Cancer Laparoscopic Adrenalectomy (Shawnee Mission Medical Center, Shawnee Mission, KS, ... MN, 1/24/2007) Colorectal Cancer Advances in Laparoscopic Colorectal Surgery (Charles E. Schmidt College of Biomedical ...