During a hypothetical severe incident in a nuclear power plant with core meltdown a large part of radioactive material is present as aerosol particles in the reactor containment. In current severe accident containment codes the potential influences of hydrogen combustions on the behaviour of aerosols are not considered. Among other effects dry resuspension can increase the aerosol concentration in the atmosphere. Already deposited aerosolmaterial can be re-released into the containment atmosphere by atmospheric currents induced by hydrogen deflagrations or by other phenomena like steam explosions. The objective is to assess the possible influence of this dry resuspension effect on the radioactive source term. (author)
This paper describes a 1993 field experiment entitled Marine Aerosol Properties and Thermal Imager Performance Trial (MAPTIP) conducted by NATO AC/243 Panel 04/RSG.8 and 04/RSG.5 in the Dutch coastal waters. Objectives were: to improve and validate vertical marine aerosol models by providing an extensive set of aerosol and meteorological measurements, within a coastal environment at different altitudes and for a range of meteorological conditions; make aerosol and meteorological observations in the first 10 m of the ocean surface with a view to extending existing aerosol models to incorporate near-surface effects; and to assess marine boundary layer effects on thermal Imaging systems. Aerosol and meteorological instruments, as well as thermal imagers and calibrated targets, were utilized. This network of instrumentation has provided a ...
This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. The program also provides significant technical and political benefits in international cooperation. We are quantifying the Spent Fuel Ratio (SFR), the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions, in a contained test chamber. In addition, we are ...
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).
In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. ...
Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).
The atmospheric processing by ozone of peptide-containing mixed particles was investigated as proxies for biogenic and sea spray primary organic aerosol. Reactions were performed in a flow reactor and particle composition was monitored by photoelectron resonance capture ionization aerosol mass spectrometry. Mixed particles containing dipeptides in a saturated organic matrix of stearic and palmitic acids showed no reaction under ozonolysis at exposure levels of 2.5???10?4?atm s O3. However reactions of mixed particles of a dipeptide (Leu-Leu) in an unsaturated matrix (oleic acid) under the same conditions resulted in a rapid loss of the peptide ion signal, as well as the carrier matrix, and appearance of a number of ion signals corresponding to secondary products. High molecular weight imid...
The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.
The sampling is described for radionuclide X-ray fluorescence analysis. Aerosols are captured with various filter materials whose properties are summed up in the table. Fine dispersed solid and liquid particles and gaseous admixtures may be captured by bubbling air through a suitable absorption solution. The concentration of small amounts of impurities from large volumes of air is done by adsorbing impurities on surfactants, e.g., activated charcoal, silica gel, etc. Aerosols may be captured using an electrostatic precipitator and aerosol fractions may be separated with a cascade impactor. Water sampling differs by the water source, i.e., ground water, surface water, rain or waste water. Soil samples are taken by probes. (ES).
The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolizedmaterials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, ...
The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolizedmaterials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, ...
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical ...
In laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), the properties of laser-generated aerosols, such as size and composition, are crucial for matrix-independent quantification. In this study, the aerosol particle morphology and elemental composition generated by two state-of-the-art laser systems (ArF excimer nanosecond-UV laser and Ti:sapphire femtosecond-IR laser) were investigated by electron microscopic techniques. Electrostatic sampling of the aerosols directly onto transmission electron microscopy (TEM) grids allowed us to study the morphology and elemental composition of the aerosols using TEM and TEM-EDX (energy dispersive X-ray spectroscopy) analyses, respectively. The results of the electron microscopic studies were finally compared to the LA-ICPMS signals of the main matrix components. The investigations were carried out for non-conducting materials ...
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO ...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase test design and a ...
We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase test design and a ...
A summary of the off-gas behavior in the HARVEST pot vitrification process is presented. Experimental runs were carried out on 3 representative wastes (MAGNOX - thermal reactor, metal fuel, THORP - thermal oxide fuel and PFR - fast reactor oxide fuel) using 2 methods of feeding the glass-formers (slurry and crizzle). Materials were carried over from the vitrification vessel into the off-gas system by entrainment supplemented by volatilization. The main volatile elements were Ru, B, Cs. Some volatility was also shown by Na and Li. The overall behavior of the off-gas was consistent with the presence in it of 5 separate aerosols of particulate matter. Sources of entrainment gave rise to 3 aerosols, and a further 2 aerosols were formed as a result of chemical reaction (Ru) and condensation (Cs) proceses involving the volatile species. Entrainment was enhanced when the feed contained free alkali nitrate. The ...
Additional measurements have been made of deposition and retention of inhaled radioactively labeled iron oxide aerosols generated by a spinning top aerosol generator.
Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full phase function versus ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...
We provide a detailed overview of an ongoing, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolizedmaterials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high energy density device, HEDD. The program participants in the U.S. plus Germany, France, and the U.K., part of the international Working Group for Sabotage Concerns of Transport and Storage Casks, WGSTSC have strongly supported and coordinated this research program. Sandia National Laboratories, SNL, has the lead role for conducting this research program; test program support is provided by both the U.S. Department of Energy and Nuclear Regulatory Commission. WGSTSC partners need this research to better understand potential ...
Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 ..mu..m; drops of diameter size 1.5 ..mu..m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water.
Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 #mu#m; drops of diameter size 1.5 #mu#m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water. ...
The conversion of highly radioactive waste liquor into glass by the pot vitrification process has been studied at Harwell using a full-scale inactive pilot plant. A summary of the off-gas behavior and its interpretation is presented. Experimental runs were carried out on 3 representative wastes (MAGNOX - thermal reactor, metal fuel, THORP - thermal oxide fuel and PFR - fast reactor oxide fuel) using 2 methods of feeding the glass-formers (slurry and crizzle). Materials were carried over from the vitrification vessel into the off-gas system by entrainment supplemented by volatilization. The overall behavior of the off-gas was consistent with the presence in it of 5 separate aerosols of particulate matter. Sources of entrainment gave rise to 3 aerosols, and a further 2 aerosols were formed as a result of chemical reaction (Ru) and condensation (Cs) processes involving the volatile species. Entrainment was ...
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The ...
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., ...
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual ...
A multielement apparatus for the removal of aerosols formed in the vitrification of simulated high-activity accident wastes from the decommissioned nuclear power plant A-1 has been designed, manufactured and tested. The apparatus consists of two cooling and condensing steps connected in series, and of five filtration steps also connected in series. The five filtration steps allowed to achieve a decontamination factor of 1x10"5 in the case of removal of a NaCl("2"4Na) testing model aerosol. The decontamination factor for removal of the cesium aerosol by the whole apparatus was 3.3x10"6. In the first filtration step the aerosols are removed by the cartridge with a filtration fabric made of polyethylene fibers, in the second step by the cartridge with a granulated natural material, in the third step by the cartridge with glass-fiber filtration paper, in the fourth and fifth steps by ...
Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431
the southern Arabian Gulf region left its signature on the heterogeneous aerosol .... Arabian Gulf region, since large differences in ? may be caused by ...
Aerosol particles are ubiquitous in the troposphere and exert an important influence on global climate and the environment. They affect climate through scattering, transmission, and absorption of...Full Text Available
The NASA Langley Distributed Active Archive Center archives and distributes data relating to Radiation Budget, Clouds, Aerosols, and Troposheric Chemistry.
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers ...
This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.
This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.
An apparatus is described for measuring the overall decontamination factor of first and second filters, the first and second filters being located in a plenum having an upstream chamber, an intermediate chamber, and a downstream chamber. The first filter is located between the upstream and intermediate chambers and the second filter is located between the intermediate and downstream chambers. The apparatus comprises a. an aerosol generator for producing a challenge aerosol composed of individual particles, the aerosol generator being in fluid communication with the upstream chamber; b. an upstream collector for collecting the challenge aerosol before the challenge aerosol enters the first filter, the upstream collector being disposed in the upstream chamber; c. an intermediate collector for collecting the challenge aerosol that passes through the first filter, ...
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without ...
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
Thin-film solar cells on flexible, lightweight, space-qualified substrates provide an attractive approach to fabricating solar arrays with high mass-specific power. A polycrystalline chalcopyrite absorber layer is among the new generation of photovoltaic device technologies for thin film solar cells. At NASA Glenn Research Center we have focused on the development of new single-source precursors (SSPs) for deposition of semiconducting chalcopyrite materials onto lightweight, flexible substrates. We describe the syntheses and thermal modulation of SSPs via molecular engineering. Copper indium disulfide and related thin-film materials were deposited via aerosol-assisted chemical vapor deposition using SSPs. Processing and post-processing parameters were varied in order to modify morphology, stoichiometry, crystallography, electrical properties, and optical properties to optimize device quality. Growth at atmospheric pressure ...
Up to now the retention of radioactive material for nuclear facilities has been based on the maximum individual dose. The maximum individual dose can locally be lowered considerably by higher dissolution. In general, the collective doses are not lowered by this. In order to set up regulations concerning collective doses, the new recommmendations of the ICRP are very welcome. However, the costs of detriment and the period to be considered have not yet been defined. Therefore there are no fixed methods for carrying out a cost-benefit analysis. Furthermore, for nuclear technology the costs and the effectiveness of the retention of radioactive material for non-realized facilities can only be quoted roughly, which makes a cost-benefit analysis more difficult. A cost-benefit analysis for the retention of radioactive material in nuclear power plants with LWRs and reprocessing plants of the PUREX process has been carried out with ...
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...
Using a model of the acidification process of rain, the authors calculate and analyze the effects and contributions of a below-cloud aerosol in its different concentrations and acidities on the pH and ion components of rain under the conditions of different concentrations of pollution gases. The results show that the aerosol has an acidification or alkalization effect on the rain which changes the pHs of rain and aerosol. As acidifying pollution gas concentrations (SO[sub 2]), HNO[sub 3] are low, the acid aerosol has important effects on the pH and H+ of rain, but as the gas concentrations are high, the acid aerosol has very little effect. The alkalizing aerosol makes the pH of rain increase by between 0.3 and 0.5 and neutralizes about 60%of H[sup +] in the rain. As alkalizing pollution gas NH[sub 3] exists, the acid aerosol has important ...
Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.
A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. ...
BackgroundRecent research highlights the promise of remotely sensed aerosol optical depth (AOD) as a proxy for ground-level particulate matter with aerodynamic diameter ≤...Full Text Available
A combined ozone and aerosol LIDAR was developed at the Institute of Physics of the Atmosphere at the DLR in Oberpfaffenhofen. It is an airborne version, that, based on the DIAL-principle, permits the recording of two-dimensional ozone profiles. This presentation will focus on the ozone-part; the aerosol subsection will be treated later.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...
NASA's Glory spacecraft is equipped to survey and map aerosols in Earth's atmosphere during a mission marking the return to flight of the Taurus XL rocket.
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included
The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past ...
The characteristics of aerosol generation were studied experimentally in an ammonia-based wet flue gas desulfurization process. Particle size distributions and concentrations, morphologies and compositions before and after desulfurization were measured using an electrical low pressure impactor and scanning electron microscopy, respectively. The results show that aerosols can be generated between ammonia and sulfur dioxide resulting in gas-phase reaction and the aerosol concentration at the outlet of scrubber is significantly higher than at the inlet. Before desulfurization the particles are primarily silica-alumina minerals including O, Al, Si and C, while after ammonia-based desulfurization aerosol particles have smooth surfaces with regular structures, such as cubic and prismatic crystal...
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of the parameters should also be as easy as ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for ...
Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...
Reliability analysis is now being used to a large extent for several civil engineering structures. Such analysis has not been used for rockfill dams, the most common dams in Norway. Following work on reliability analysis for breakwaters, reliability analysis was then used to investigate the ability of the stone material on the upstream face of a rockfill dam to withstand wind generated waves. An attempt is made to follow up this work by including discharge overtopping on a rockfill dam in a reliability analysis. This report primarily goes through previous work on the required weight of protective stones on the downstream face of the dam for specified discharges over the dam and also deals with the probability formulation of extreme floods. A failure function with partial coefficients is formulated. But for reasons of economy the calibration of the partial coefficients remains for a next phase of the project. 14 refs., 17 figs.
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.
Theoretical and experimental research efforts in evaluating an innovative concept for vertical axis wind turbines (VAWT) are described. The concept is that of using straight blades composed of circulation controlled airfoil sections. The theoretical analysis has been developed to determine the unsteady lift and moment characteristics of multiple-blade cross-flow wind turbines. To determine the drag data needed as input to the theoretical analysis, an outdoor test model VAWT has been constructed; design details, instrumentation, and calibration results are reported. Initial testing is with fixed pitch blades having cross-sections of conventional symmetrical airfoils. Costs of building the test model are included, as well as estimates for blades constructed with composite materials. These costs are compared with those of other types of wind turbines.
A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.
A workshop on radioactivity in coal use was held on September 15 through 17, 1981, under the auspices of the US Department of Energy, Office of Environmental Programs, and the Los Alamos National Laboratory. The purpose of the workshop was to identify research issues associated with radioactivity resulting from the use of coal for electric power generation. The concensus of the 10 scientists participating in the workshop was that a moderate to strong need exists for research in solubility of fly ash in different fluids and for determination of radioactivity in construction materials. Several additional research issues were identified but were given a lower priority. Summaries of each presentation are included. Titles are: some effects of coal combustion on the radiation environment; radionuclides in western coal at Mound; low-level radiation in coals utilized and ashes produced at New York State electric utilities; radioactivity from coal use - where are the ...
Mullite long fibres, which are a candidate for high temperature applications were prepared by sol-gel method from water solvent systems. They were synthesized from three different combinations of raw materials as follows: (1):Al(O{sub 1}C{sub 3}H{sub 7}){sub 3}, Al-nitrate and Si(OC{sub 2}H{sub 5}){sub 4} (TEOS), (2):Al metal, Al-chloride and TEOS, (3):Al metal, Al-nitrate and TEOS. In the methods (1) and (2), very fine SiO{sub 2} aerosol particles were also used partially replacing TEOS. The prepared solutions were condensed and examined the spinability by a hand drawing method. Dense and crack free mullite fibres were prepared from the methods (1) and (3) by firing up to 1100 C. Whereas the fibres prepared from the method (2) were less SiO{sub 2} than mullite composition and were porous by the firing due to evaporation of residual Cl ions at high temperature. (orig.) 10 refs.
Aerosol and gas measurements were made with the University of Minnesota Mobile Laboratory (UMML) during the VISTTA programme near Page, Arizona. The UMML was stationed on Zilnez Mesa approx. 65 km east of the Navajo coal-fired power plant. Measurements were made both in and out of the power plant plume and were made during the day and night. Measured parameters included aerosol size distributions, Aitken nuclei count, ozone and sulphur dioxide concentrations, the aerosol light scattering coefficient, and meteorological parameters including ultraviolet radiation intensity. Concentrations of NO and NO/SUB/x were occasionally measured. Data show clear evidence of gas-to-particle conversion in the plume with aerosol volume being added in the 0.01 MUm - 0.32 MUm dia. range and new particles being formed. The observed excess aerosol volume depends strongly upon the SO/SUB/2 concentrations ...
The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.
The admissibility of nuclear forensics measurements and opinions derived from them in US Federal and State courts are based on criteria established by the US Supreme Court in the case of Daubert v. Merrell Dow and the 2000 Amendment of Rule 702 of the Federal Rules of Evidence. These criteria are being addressed by new efforts that include the development of certified reference materials (CRMs) to provide the basis for analytical method development, optimization, calibration, validation, quality control, testing, readiness, and declaration of measurement uncertainties. Quality data is crucial for all stages of the program, from R and D, and database development, to actual casework. Weakness at any point in the program can propagate to reduce the confidence of final conclusions. The new certified reference materials will provide the necessary means to demonstrate a high level of metrological rigor for nuclear forensics ...
During the water detritiation process most of the tritium inventory is transferred from water into the gaseous phase, then it is further enriched and finally extracted and safely stored. The control of tritium inventory is an acute issue from several points of view: - Financially - tritium is an expensive material; - Safeguard - tritium is considered as nuclear material of strategic importance; - Safety - tritium is a radioactive material: requirements for documented safety analysis report (to ensure strict limits on the total tritium allowed) and for evaluation of accident consequences associated with that inventory. Large amounts of tritium can be stored, in a very safely manner, as metal tritides. A bench-scale experiment of a tritium storage bed with integrated system for in-situ tritium inventory accountancy was designed and developed at ICSI Rm. Valcea. The calibration curve and the detection ...
Major advances in 'Energy and Materials Cycles' have been achieved in the removal of heavy metals from the solid residues of municipal waste incineration. It has been conclusively shown that the oxidation/reduction conditions established during the thermal treatment of filter ash have a decisive influence on the evaporation of groups of heavy metals. With respect to biomass gasification, studies have been carried out with respect to the best way of extracting pure hydrogen from the low calorific value gas that is typically obtained from a biomass gasifier. The overarching goal of the laboratory 'High Temperature Solar Technology' is the use of solar energy for the production of solar fuels, or for the reduction of CO{sub 2} emissions in large scale industrial processes that are conventionally carried out with the use of fossil fuels. In a short-term project targeted at the solar production of lime, highly encouraging results (98% ...
When combining aerosol retention components in the dissolver offgas stream of a reprocessing plant, the behavior both of the individual aerosol filter stages and the overall removal efficiency of all filters connected in series vis-a-vis an aerosol spectrum to be expected must be determined for the benefit of the licensing authority. A fast method of determining removal efficiencies is described, which can also be applied in hot operation. This method was used to demonstrate, with high certainty, decontamination factors of a whole filter train in the range of 10"7.
This contribution analyzes elastic-backscatter lidar data and temperature and humidity profiles from radiosondes acquired in Barcelona in July 1992. Elastic-backscatter lidar data reveal the distribution of aerosols within the volume of atmosphere scanned. By comparing this information with temperature and humidity profiles of the atmosphere at a similar time, we are able to asses de relationship among aerosol distribution and atmospheric stability or water content, respectively. Comparisons have shown how lidar`s revealed layers of aerosols correspond to atmospheric layers with different stability condition and water content.
The article focusses on operational experience gained with the following items: scrubbing system with oxidation, regenerative gas preheater, blower/fan, aerosol filter, and product processing. (orig./PW).
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing aerosol on the distance ...
This article addresses the need for new data on indirect effects of natural and anthropogenic aerosol particles on atmospheric ice clouds. Simultaneous measurements of the concentration and composition...Full Text Available
A 340-watt CO_2 laser is being used to generate PuO_2-UO_2 condensation aerosol from the surface of a Liquid Metal Fast Breeder Reactor (LMFBR) fuel pellet. A wide range of concentrations is achieved by varying the laser power, pulse width, and/or pulse period. The resulting aerosol is composed of branch chain-like aggregates, with the primary particle size ranging between 0.005 and 0.15 #mu#m. X-ray diffraction analyses show that these aerosols condense into a face-centered cubic crystal structure. The activity mean aerodynamic diameter (AMAD), for most power levels, is approximately 0.85 #mu#m with a geometric standard deviation of 1.5.
Photoelectron resonance capture ionization aerosol mass spectrometry (PERCI-AMS) has been applied to the analysis of proxies for marine aerosols with and without ozone; proxies used were mixed oleic acid-amino acid particles. The mechanism of ion formation for serine (104 m/z), glutamic acid (146 m/z), and phenylalanine (164 m/z) was dissociative electron attachment. This corresponds to loss of the hydrogen atom only, allowing for straightforward identification of the free amino acids. No ozonolysis products for the free amino acids were observed, even at high concentrations of ozone (500 ppm for 19 s). The direct detection of a novel gas-phase hydrated anion, [serine + H2O-H]-, is described. These preliminary results suggest that PERCI-AMS may provide an effective, simple and direct onlin...
The project is focusing on the formation and growth mechanisms of atmospheric aerosol and cloud droplets. Both aerosol particles and cloud droplets affect strongly on the atmospheric radiation fluxes by scattering and absorption. The droplet formation results from physical and chemical processes occurring simultaneously. The studies concerning the tropospheric cloud droplet formation, laboratory experiments with a cloud chamber and stratospheric cloud formation are summarized. The recent studies summarized in this presentation indicate that both aerosol particles and cloud droplets have a significant role in climatic change and ozone depletion problems. The anthropogenic emissions of gaseous and particulate pollutants change the properties of atmospheric aerosols and cloud droplets. The research in this field will be continued and more quantitative understanding based both experimental and theoretical ...
The effect of aerosol on clouds poses one of the largest uncertainties in estimating the anthropogenic contribution to climate change. Small human-induced perturbations to cloud characteristics via aerosol pathways can create a change in the top-of-atmosphere radiative forcing of hundreds of Wm-2. Here we focus on links between aerosol and deep convective clouds of the Atlantic and Pacific Intertropical Convergence Zones, noting that the aerosol environment in each region is entirely different. The tops of these vertically developed clouds consisting of mostly ice can reach high levels of the atmosphere, overshooting the lower stratosphere and reaching altitudes greater than 16 km. We show a link between aerosol, clouds and the free atmosphere wind profile that can change the magnitude and sign of the overall climate radiative forcing. We find that increased ...
From aerosol spectral optical depths ({tau}{sub p{lambda}}) at wavelengths in the range 380 to 1025 nm estimated at different locations in the near and far coastal regions of the Arabian sea adjoining the western coast of central India, the spatial and spectral characteristics of coastal aerosols and the effect of the proximity to the (urban) continent are investigated. The Aangstroem parameters are deduced from {tau}{sub p{lambda}} values. A significant increase, both in aerosol optical depths at shorter (visible) wavelengths ({lambda} {<=} 600 nm) and the Aangstroem wavelength exponent are observed in the near coastal regions, suggesting an increase in the (relative) concentration of sub micron particles, apparently of anthropogenic origin. The Aangstroem turbidity coefficient remains nearly steady spatially, indicating a (spatially) uniform loading of large particles. 31 refs, 10 figs, 1 tab
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
Recently there has been much concern with the ability of plants to uptake heavy metals from their surroundings. With the development of instrumental techniques with low detection limits such as inductively coupled plasma-mass spectrometry (ICP-MS), attention is shifting toward achieving faster and more elegant ways of oxidizing the organic material inherent in environmental samples. Closed-vessel microwave dissolution was compared with conventional methods for the determination of concentrations of cerium, samarium, europium, terbium, uranium and thorium in a series of samples from the National Institute of Standards and Technology and from fields in Idaho. The ICP-MS technique exhibited detection limits in parts-per-trillion and linear calibration plots over three orders of magnitude for the elements under study. The results obtained by using nitric acid and hydrogen peroxide in a microwave digestion system for the analysis of reference ...
A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different ...
The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...
The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...
The Coal Fired Combined Cycle (CFCC) is the unique powerplant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined cycle powerplant. On the basis of previous studies and confirming work under this contract, General Electric continues to believe that the CFCC approach offers important advantages over alternate approaches: higher powerplant efficiency in the combustor temperature range of interest; reduced combustor/steam generator corrosion potential, due to low fluid-bed tube temperature (as contrasted to the air in tube cycle); and increased gas turbine bucket life from improved material protection systems. The objective of this program is to evaluate the coal fired combined cycle powerplant conceptual design, and to conduct a supporting development program. The supporting development is required for evaluating the pressurized fluidized bed combustion concept, for developing ...
Aircraft constitute a unique environment which places stringent requirements on the instruments used to measure the concentrations of atmospheric trace gases and aerosols. Some of these requirements such as minimization of size, weight, and power consumption are general; others are specific to individual techniques. This review presents the basic principles and considerations governing the deployment of trace gas and aerosol instrumentation on an aircraft. An overview of common instruments illustrates these points and provides guidelines for designing and using instruments on aircraft-based measurement programs.
The Two-Column Aerosol Project (TCAP) field campaign will provide a detailed set of observations with which to (1) perform radiative and cloud condensation nuclei (CCN) closure studies, (2) evaluate a new retrieval algorithm for aerosol optical depth (AOD) in the presence of clouds using passive remote sensing, (3) extend a previously developed technique to investigate aerosol indirect effects, and (4) evaluate the performance of a detailed regional-scale model and a more parameterized global-scale model in simulating particle activation and AOD associated with the aging of anthropogenic aerosols. To meet these science objectives, the Atmospheric Radiation Measurement (ARM) Climate Research Facility will deploy the ARM Mobile Facility (AMF) and the Mobile Aerosol Observing System (MAOS) on Cape Cod, Massachusetts, for a 12-month period starting in the summer of 2012 in order to ...
Preliminary results suggest that Pu(NO_3)_4 inhaled as crystalline solid aerosol is retained more tenaciously in the lung and excreted less in urine than inhaled Pu(NO_3)_4 aerosols generated from a nitric acid solution.
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.
An observational and modeling study was performed over the Arabian Gulf region to investigate the coastal circulations and aerosol transport in the area. Climatological data and observations from the United Arab Emirates' Unified Aerosol Experiment were used to develop a better understanding of the complex meteorological processes in the Arabian Gulf region. Climatological data suggests that sea breezes occur on more than 77 percent of days in all months of the year and land breezes occur on more than 70 percent of the days. The occurrence of the sea and land breeze circulations are higher (90-99 percent) during the summer months when large-scale weather patterns are quiescent. Measurements of aerosol concentrations taken during the Unified Aerosol Experiment(2004) experiment are used to investigate aerosols, namely dust, transported in the Arabian Gulf region. Vertical profiles of ...
... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... Aerosol Chemical Processes in the Environment Spurny, Kvetoslav R., $164,95, 䀈... More Journals » MAGAZINES & JOURNALS Water Science & Technology: Water Supply Water Science and Technology: Water Supply is p... ...
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available
In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.
An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the ...
The close-in extrasolar giant planets (CEGPs) reside in irradiated environments much more intense than that of the giant planets in our solar system. The high UV irradiance strongly influences their photochemistry and the general current view believed that this high UV flux will greatly enhance photochemical production of hydrocarbon aerosols. In this letter, we investigate hydrocarbon aerosol formation in the atmospheres of CEGPs. We find that the abundances of hydrocarbons in the atmospheres of CEGPs are significantly less than that of Jupiter except for models in which the CH$_4$ abundance is unreasonably high (as high as CO) for the hot (effective temperatures $\\gtrsim 1000$ K) atmospheres. Moreover, the hydrocarbons will be condensed out to form aerosols only when the temperature-pressure profiles of the species intersect with the saturation profiles--a case almost certainly not realized in the hot CEGPs atmospheres. ...
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a ...
This facility has treatment capacity of 12 kg/hr, and is equipped with a furnace, two ceramic filter chambers, each of which hangs inside the 36 ceramic filter elements having mean pore size of 44 #mu#m. Three series of experiments were performed during a period from October 1972 to August 1973. The first was measurement of the change of pressure drop of the primary and the secondary filters after an operation of 52 days (352 hours). The pressure drop of the primary filter did not change during the operation, but the secondary brought a fairly large increment, from 79 to 140 mmAq. The second was measurement of the after-burning effect of the primary filter for the soot and tar in the off-gas. Through the after-burning most of the soot was removed from the off-gas, though the tar was not perfectly taken off. At the secondary filter, some of the tar was burnt, but most of it was caught by the filter as aerosol. The third was measurement of decontamination factors of ...
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional advantage of requiring ...
Specimen strips of pure alpha titanium and beta titanium alloy were exposed to a range of up to 46 deuterium plasma discharges in the Princeton Large Torus Tokamak (PLT) under simulated first wall conditions, and the amount of trapped deuterium in these specimens was measured, using carbon as a calibration standard for trapping. The Deuterium Nuclear Microprobe was used to study the total trapped deuterium and the deuterium depth distribution in the exposed materials before and after annealing at 373 and 423"0K. The Scanning Auger Microprobe was used to identify the effects of surface impurities on the deuterium distribution. Results indicate that about 20 to 40% of the incident deuterium was trapped by the surface and about 90% of the trapped deuterium remained in a 20A carbonaceous film deposited during plasma exposure. Annealing resulted in a gradual loss from the film. These results indicate the importance of impurity film formation which ...
Aerosols affect the radiative energy budget on both the regional and global scales. The wavelength-dependent aerosol optical depth (AOD) is a fundamental determinant of the amount by which extra-terrestrial incoming sunlight and outgoing terrestrial radiation are being attenuated in the atmosphere. The present study addresses the influence of local waste burning on aerosol characteristics, black carbon (BC) aerosol mass concentration and spectral solar irradiance using ground-based measurements over the tropical urban environment of Hyderabad, India. AOD has been observed to be maximum during burning days compared to normal days. Aerosol size spectra suggest bimodal distributions during pre-and post-burning periods and trimodal distributions during burning periods. Angstrom wavelength exponent estimated from spectral variation of AOD suggested dominance of accumulation mode particle ...
Anthropogenic sulfate aerosol, together with particles from biomass burning, may significantly reduce the climatic warming due to man-made greenhouse gases. The radiative forcing of aerosol particles is based on their ability to scatter and absorb solar radiation (direct effect), and on their influences on cloud albedos and lifetimes (indirect effect). The direct aerosol effect depends strongly on the size, number and chemical composition of particles, being greatest for particles of 0.1-1 {mu}m in diameter. The indirect aerosol effect is dictated by the number of particles being able to act as cloud condensation nuclei (CCN). For sulfate particles, the minimum CCN size in tropospheric clouds is of the order of 0.05-0.2 {mu}m. To improve aerosol parameterizations in future climate models, it is required that (1) both primary and secondary sources of various particle types will be ...
Chemical composition of fine aerosol particles over the northern Chilean coastal waters was determined onboard the U.S. DOE G-1 aircraft during the VOCALS (VAMOS Ocean-Cloud-Atmosphere-Land Study) field campaign between October 16 and November 15, 2008. SO42-, NO3-, NH4+, and total organics (Org) were determined using an Aerodyne Aerosol Mass Spectrometer, and SO42-, NO3-, NH4+, Na+, Cl-, CH3SO3-, Mg2+, Ca2+, and K+ were determined using a particle-into-liquid sampler-ion chromatography technique. The results show the marine boundary layer (MBL) aerosol mass was dominated by non- sea-salt SO42- followed by Na+, Cl-, Org, NO3-, and NH4+, in decreasing importance; CH3SO3-, Ca2+, and K+ rarely exceeded their respective limits of detection. The SO42- aerosols were strongly acidic as the equivalent NH4+ to SO42- ratio was only ~0.25 on average. NaCl particles, presumably of sea-salt origin, showed chloride ...
The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We ...
Recent work has shown that natural hydrocarbon emissions can significantly affect the levels of urban and regional tropospheric ozone. We report on the reactivities of these biogenic trace gases, particularly isoprene, focusing on their importance in the production of aldehydes and peroxy radicals, leading to increased levels of hydrogen over regional forests. Hydrogen peroxide can lead to the wet oxidation of sulfur dioxide to acidic sulfate in aerosols, fogs, and clouds. In turn, acidic sulfate can act to as a light scattering aerosol and a source of cloud condensation nuclei (CCN), potentially leading to global cooling. Aerosol sulfate and other dissolved organic and inorganic compounds can also play important roles as a greenhouse species in the lower troposphere.
The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.
Evaporation of "9"9"mTc-pertechnetate at about 2500"0C on a carbon surface generates an ultrafine aerosol of labelled carbon clusters. Its particle size of about 2-5 nm enables the aerosol to behave similarly to a gas regarding the ability of penetration. After inhalation, the radioactive particles adhere to the walls of the respiratory bronchioli and alveoli. The high concentration of the radioactivity in the argon carrier gas makes it possible to record a scintigram after a single deep breath. We studied four healthy volunteers and 79 patients including 34 with a tentative diagnosis of pulmonary embolism, 20 with bronchus carcinoma, and 15 with various other lung diseases. Ten of these patients were infants, the youngest being nine months old. All patients also had a perfusion scintigraphy. (orig.).
The possible physical linkage between galactic cosmic rays intensity and the Earth's cloud cover is discussed using the analysis of the first indirect aerosol effect (Twomey effect) and its experimental representation as the dependence of average cloud droplet effective radius on aerosol index characterizing the aerosol concentration in the atmospheric air column of unit section. It is shown that the basic kinetic equation of the Earth's climate energy-balance model is described by the bifurcation equation (with respect to the temperature of the Earth's surface) in the form of fold catastrophe with two governing parameters defining the variations of insolation and Earth's magnetic field (or galactic cosmic rays intensity in the atmosphere), respectively. The principle of hierarchical climatic models construction, which consists in the structural invariance of balance equations of these models evolving on the different time ...
Papers are presented on the modeling, dispersion, formation, transformation, monitoring and biological effects of atmospheric pollution. Specific topics include a prognostic mesoscale model for pollutant transport and diffusion, commuter exposure modeling, a Gaussian plume model for an urban area, carbon monoxide dispersion in an urbanized area, wind-tunnel modeling of flue gas dispersion, the regional-scale transport of fine aerosol components in eastern North America, and a Markov process for the generation of hourly average wind vectors. Attention is also given to photochemical aerosol formation in multicomponent systems, heterogeneous nitrogen oxide-particulate reactions, the generation and measurement of primary soot aerosols of size between 50 and 400 A, inertial particle size classification techniques, the design of air quality monitoring networks, visibilities in polluted and unpolluted areas, and monitoring air ...
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of par...
An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent "1"4C analysis is described. The outcome of the programme will provide a detailed quantification of the uncertainties associated with "1"4C measurements including the issues of accuracy and precision. Such projects have become recognised as a fundamental aspect of continuing laboratory quality assurance schemes, providing a mechanism for the harmonisation of measurements and for demonstrating the traceability of results. The design of this study and its rationale are described. In summary, a suite of core samples has been defined which will be made available to both AMS and radiometric laboratories. These core materials are representative of routinely dated material and their ages span the full range of the applied "1"4C ...
Wood Plastic Composites (WPCs) have experienced a healthy growth during the last decade. However, improvement in properties is necessary to increase their utility for structural applications. The toughness of WPCs can be improved by creating a fine cellular structure while reducing the density. Extrusion processing is one of the most economical methods for profile formation. For our study, rectangular profiles were extruded using a twin-screw extrusion system with different grades of HDPE and with varying wood fibre and lubricant contents together with maleated polyethylene (MAPE) coupling agent to investigate their effects on WPC processing and mechanical properties. Work has been done to redesign the extrusion system setup to achieve smoother and stronger profiles. A guiding shaper, submerged in the water, has been designed to guide the material directly through water immediately after exiting the die; instead of passing it through a water cooled vacuum ...
Full text: Nuclear material is subjected to chemical processing throughout the entire fuel cycle. Traces of the chemical reagents and solvents are left behind in the nuclear material. So far essentially metallic impurities or light elements have been investigated for their potential in providing clues on the type of process they originate from. In the present investigation, the applicability of anions for attributing nuclear material to a certain chemical process has been investigated. Anions (e.g. nitrate, sulphate, phosphate, chloride) originate from acids or salt solutions that are used for processing of solutions containing uranium or plutonium. The study presented in this paper focuses on yellow cake samples originating from different mines applying different chemical processes for leaching, dissolving and precipitating the uranium. Consequently, the anionic patterns should be different. The concentrations of different ...
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This ...
Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...
Mechanistic models of aerosol decontamination by an overlying water pool during core debris/concrete interactions and spray removal of aerosols from a Mark I drywell atmosphere are developed. Eighteen uncertain features of the pool decontamination model and 19 uncertain features of the model for the rate coefficient of spray removal of aerosols are identified. Ranges for values of parameters that characterize these uncertain features of the models are established. Probability density functions for values within these ranges are assigned according to a set of rules. A Monte Carlo uncertainty analysis of the decontamination factor produced by water pools 30 and 50 cm deep and subcooled 0--70 K is performed. An uncertainty analysis for the rate constant of spray removal of aerosols is done for water fluxes of 0.25, 0.01, and 0.001 cm{sup 3} H{sub 2}O/cm{sup 2}-s and decontamination factors of 1.1, 2, 3.3, ...
The concentration of some organic acids in the atmosphere was determined using a wet effluent diffusion denuder-aerosol collector coupled with Ion Chromatography. Three organic acids and four inorganic anions were identified and quantified in the air sample, taken from the backyard of PSI. (author)
As part of the 1999 NARSTO Northeast Oxidant and Particulate Study (NE-OPS) field campaign, the DOE G-1 aircraft sampled trace gases and aerosols in and around the Philadelphia metropolitan area. Twenty research flights were conducted between July 25 and August 11. The overall goals of these flights were to obtain a mechanistic understanding of O(sub 3) production; to characterize the spatial and temporal behavior of photo-oxidants and aerosols; and to study the evolution of aerosol size distributions, including the process of new particle formation. Within the NE-OPS program, other groups provided additional trace gas, aerosol, and meteorological observations using aircraft, balloon, remote sensing, and surface based instruments (Phillbrick et al., 2000). In this article we provide an overview of the G-1 observations related to O(sub 3) production, focusing on the vertical distribution of pollutants. ...
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
Air pollution measurements were conducted over a 1-year period in 24 North American communities participating in a respiratory health study. Ozone, particle strong acidity, sulfate, and mass (PM10 and...Full Text Available
retrieve detailed aerosol and cloud particle size distribution and shape ...... but on rain types, and hydrometeor characteristics. ..... of ice streams, decreasing sea ice cover in the Arctic, poleward movement of forest cover, and ...
Chemoprevention strategies to prevent the development of lung cancer in at-risk individuals are a key component in disease management. In addition to being highly effective, an ideal chemopreventive...Full Text Available
Results related to the experimental measurement campaign to characterize atmospheric aerosol carried out near Avigliana (Turin) from 18 to 22 October 1994 are presented in this paper. In the frame of the project aimed at evaluating the impact of the mountain motor way A-32 Rivoli-Bardonecchia-Frejus on the Susa Valley environment and on man the present measurement campaign is the second, and last, one envisaged in the project. The sampling place is in the initial part of the Susa Valley while previous measurements were carried out in the high part of it. Mass mean concentrations result greater in the low than in the high part of the valley approximately by a factor of 3. It is not possible to prove a difference between the 3 sampling positions transversely placed from 20 to 80 m. in comparison with the motor way axis. Whereas mass mean concentrations dropped substantially due to atmospheric precipitations during the last two measurement day. ...
Remote sensing data over North America document the ubiquity of secondary aerosols resulting from a combination of primary biogenic and anthropogenic emissions. The spatial and temporal distribution...Full Text Available
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of particle introduction, assessed using Trypan blue dye exclusion, had no effect on cell viability. In combination with a differential ...
Hypersensitivity pneumonitis (HP) is an inflammatory lung disease caused by repeated inhalation of aerosolized antigens. With chronic exposure to an inhaled antigen, patients are at risk of...Full Text Available
The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...
Mar 1, 2011 ... The movement of hydrothermal fluids and/or fumarolic vapors through local rocks prior ... The Solar Energetic Particle Event of December 14, 2006 .... for measurement of non-precipitating cloud hydrometeors and aerosols, ...
This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.
Adult and newborn rats were exposed to "2"3"9PuO_2 aerosols of four different size distributions. Rats of both ages were killed at intervals between 1 hr and 60 days postexposure. There were marked age- and particle-related size differences in deposition, although retention was similar throughout. The differences in deposition are attributable to relatively greater deposition of larger particles in the upper respiratory tracts of newborns.
Abstract First results showing the viability of combining laser chemical processing (LCP) and aerosol jet printing (AJP) technologies to produce a high-efficiency front side for silicon solar cells are presented. LCP simultaneously opens the anti-reflection coating (ARC) and highly dopes the underlying silicon to create a selective emitter, while AJP is the first in a two-step fine-line contact formation procedure. The electrical properties as well as the morphology of the resulting structures are presented. Performance similar to that achieved with evaporated TiPdAg metallization is demonstrated. Copyright 2010 John Wiley & Sons, Ltd.
Large amounts of atmospheric dust are lifted from the North African deserts and are transported by the trade winds over the Caribbean region, especially during the summer months. How African dust particles influence the earth's radiative budget is not well understood because these particles are highly variable and their physical, optical, and chemical properties are poorly characterized, especially when they are atmospherically processed as are those that travel from Africa to the Caribbean region. Here we present results of aerosol measurements performed at Cape San Juan (CPR), a ground-based station located at the northeastern tip of the Caribbean island of Puerto Rico. We used a condensation particle counter to determine the particle number concentration, a sunphotometer (part of the AErosol RObotical NETwork, AERONET, aeronet.gsfc.nasa.gov) to determine volume size distributions and aerosol optical thickness, and ...
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...
This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...
The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...
Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...
... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
The lignite used for Phase I of the project was a Texas lignite from the Martin Lake mine obtained from the stockpile for the Martin Lake Power Plant of the Texas Utilities Generating Company. The power requirements for the fluid-energy mill were determined from the measured steam (or air) temperatures, pressures and pressure drops and the lignite flow rate. The instrument locations for the tests are shown on Figure 1. All of the instruments were connected to a microcomputer via an analog input interface board. Data were recorded on disks periodically throughout the tests. Appropriate calibration procedures were followed to assure that reliable data were being obtained. The combined grinding/drying tests were conducted in Vicksbuth, MS at Ergon, Inc.'s fluid-energy-mill facility. both steam and air were used as grinding fluids. With steam, tests were used as grinding fluids. With steam, tests were run with the following temperatures maintained inside the ...
Synthetic zeolite of 0.5 nm pore size (5A) and blue silica gel were tested to determine their capability to be used as radon collectors. Tests conducted in a radon chamber under controlled conditions of temperature and relative humidity indicate that simple, inexpensive and maintenance-free passive devices containing about 250 g of synthetic zeolite or about 270 g of blue silica gel in open face metal canisters that can measure radon conveniently and adequately, the latter though being suitable only for dry-medium dry atmosphere with quite high radon concentrations. Both materials can be recycled for reuse, in a way similar to the recycle and reuse of active carbon. The amount of radon adsorbed in such collectors is determined by counting the gamma rays from the radon decay products. The lower limit of detection (LLD) is estimated to {approx}45 Bqm{sup -3} for the synthetic zeolite and to {approx}350 Bqm{sup -3} for the blue silica gel, for an exposure of 48 h at a ...
The paper describes the production of highly enriched isotopes of uranium, plutonium, americium and curium by electromagnetic separation for scientific and applied researches in physics, chemistry, geology, medicine, biology and other fields. Using the equipment described, the isotopes are produced in quantities sufficient to set up nuclear physical experiments, to produce nuclear reference materials and standard sources for calibration of radiometrical and mass spectrometrical equipment, in radionuclide metrology, etc. For the following isotopes the indicated degrees of isotopic enrichment were achieved: "2"3"3U-99.97%; "2"3"5U-99.97%; "2"3"6U-98.0%; "2"3"8U-99.997%; "2"3"8Pu-99.6%; "2"3"9Pu-99.9977%; "2"4"0Pu-99.9-100%; "2"4"1Pu-96.998%; "2"4"2Pu-97.8-99.96%; "2"4"4Pu-96.7%; "2"4"1Am-99.6%; "2"4"2"mAm-73.6%; "2"4"3Am-99.2-99.94%; "2"4"3Cm-99.99%; "2"4"5Cm-99.998%; "2"4"6Cm-99.8%; "2"4"7Cm-90%, "2"4"8Cm-97%. Methods for preparing layers of ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried out under high OH ...
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As career aerosols of radon progeny, carnauba ...
The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August University of Goettingen in mid-April 1994 (Goettingen University, TUeV Saxonia and Bavaria) and from June ...
Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to ...
The effectiveness of Noveko's antimicrobial filter was evaluated after 16 months of exposure to commercial swine production. The experiment involved the use of a scaled model of a commercial swine facility consisting of 2 small chambers connected by a duct containing the filters. A 5 kg naive pig was placed in the reception chamber for a period of 6 hours after aerosolization with porcine reproductive and respiratory syndrome virus (PRRSV). Blood samples from pigs were collected before and after aerosolization to test for the presence of PRRSV RNA. Only blood samples were tested for PRRSV antibodies by IDEXX 2XR ELISA. None of the 9 pigs tested were found to be infected. The study showed that the technology used to integrate the antimicrobial agent into the filter fibers allows the filter combination to withstand extreme weather and endure commercial swine production for at least 16 months, and can maintain its effectiveness to avoid ...
Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined source terms. The code accurately reproduces ...
Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined source terms. The code accurately reproduces ...
DF (decontamination factor) of two types of air filter was investigated against /sup 198/Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 ..mu..m and sigmag (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mmphi, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mmphi. DF of the SO filter was found to be over 5 x 10/sup 4/ at air flow rate of 1 lmin. And DF of HE-40 T filter was determined to be 94+-4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each successive filter. It was also confirmed that DF could be predicted by the numerical simulaiton, if particle penetration function of filter and size distribution function of ...
DF (decontamination factor) of two types of air filter was investigated against "1"9"8Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 #mu#m and #sigma#g (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mm#phi#, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mm#phi#. DF of the SO filter was found to be over 5 x 10"4 at air flow rate of 1 l/min. And DF of HE-40 T filter was determined to be 94#+-#4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each successive filter. It was also confirmed that DF could be predicted by the numerical simulaiton, if particle penetration function of filter and size distribution function of ...
Observational evidence is presented for the nucleation of condensation nuclei (CN) in the clear air adjacent to an isolated, marine, cumulus cloud. Two separate regions of particle nucleation are identified: one located above the cloud top, and the second located downwind of the cloud near the level of the anvil outflow. The regions of high CN concentrations were located in extremely clean marine air, with unactivated aerosol surface area (excluding the nucleation mode) less than 2 sq micrometers/cu cm, air temperature -31 C, and higher relative humidities than the undisturbed environment. Vertical profile measurements downwind of the cloud showed that CN concentrations at the level of the anvil outflow (4.9 km) were 8 times greater than at any other level between the surface and 5.3 km. A conceptual model is formulated in which aerosol particles, sulfur dioxide (SO2), sulfuric acid vapor (H2SO4), dimethyl sulfide (DMS), and ozone (O3) from the ...
There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.
The Toxicological Evaluation of Realistic Emissions of Source Aerosols (TERESA) study involved withdrawal, aging, and atmospheric transformation of emissions of three coal-fired power plants. Toxicological evaluations were carried out in rats exposed to different emission scenarios with extensive exposure characterization. Data generated had multiple levels of resolution: exposure, scenario, and constituent chemical composition. Here, we outline a multilayered approach to analyze the associations between exposure and health effects beginning with standard ANOVA models that treat exposure as a categorical variable. The model assessed differences in exposure effects across scenarios (by plant). To assess unadjusted associations between pollutant concentrations and health, univariate analyses...
Through an international collaborative effort, a special version of the CONTAIN code is being developed for integrated mechanistic analysis of the conditions in liquid metal reactor (LMR) containments during severe accidents. The capabilities of the most recent code version, CONTAIN LMR/1B-Mod.1, are discussed. These include new models for the treatment of two condensables, sodium condensation on aerosols, chemical reactions, hygroscopic aerosols, and concrete outgassing. This code version also incorporates all of the previously released LMR model enhancements. The results of an integral demonstration calculation of a sever core-melt accident scenario are given to illustrate the features of this code version. 11 refs., 7 figs., 1 tab.
The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm/sup -2/, and then 1 g of powdered sample (0.08 g cm/sup -2/) was placed on the disk and repressed at 1.6 t cm/sup -2/. X-ray measurements were performed for total XRF intensity (I/sub p/) at the characteristic line of each element and background intensity (I/sub b/) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I/sub p/ - I/sub b/ vs. concentration for Ca, Na and Pb and by the plot of I/sub p//I/sub b/ ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, ...
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm"-"2, and then 1 g of powdered sample (0.08 g cm"-"2) was placed on the disk and repressed at 1.6 t cm"-"2. X-ray measurements were performed for total XRF intensity (I_p) at the characteristic line of each element and background intensity (I_b) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I_p - I_b vs. concentration for Ca, Na and Pb and by the plot of I_p/I_b ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, Cu, Zn, Pb, Sr and Ba, respectively. The ...
The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...
The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...
Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements ...
GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...
The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...
This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...
BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
BackgroundThere are several known factors that cause ischemic heart disease. However, the part played by air pollution still remains something of a mystery. Recent attention has...Full Text Available
Possible causes of forest damage are discussed. Mapping of affected areas by various workers resulted in dissimilar pictures. Release of radioactive rare gases, aerosols, tritium and carbon-14 seems unlikely to have a significant influence on forest damage. Influence of radioactive fallout, ozone formation by high-voltage transmission lines and synergistic effects is also found to be negligible.
Sulfuric acid and its partially or completely neutralized salts with ammonia are believed to result from the oxidation of sulfur dioxide in cloud water and in other heterogeneous media present in the atmosphere. Due to the natural abundance of ammonia and the ubiquitous presence of sulfur in the atmosphere, (NH/sub 4/)/sub 2/SO/sub 4/ is commonly the dominant chemical species in the ambient aerosol. The amounts of ammonium sulfates are expected to be very low in areas far removed from anthropogenic emissions of sulfur dioxide. The chemical composition of submicrometer aerosol particles was determined at the Mauna Loa Observatory (MLO) on Mauna Loa in Hawaii during an eight-day period in August 1986. The MLO site was selected for this measurement because it is the only ground-based aerosol observatory in the remote Pacific Ocean that allows extended sampling of aerosols in the free troposphere. ...
A method is described to smear extremely thin layers of nuclear emulsion on labeled electron microscope preparations and to measure the thicknesses of these layers, Without further separation, preparation and emulsion can be observed after exposure and development in an electron microscope. The source of the tracks formed in the emulsion can be exactly identified and the size and structure determined. This method finds applications in dust research and also in the analysis of medical and biological sections. Further information can be obtained about properties of different emulsions. (auth)
... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... Light Scattering Media Optics Alexander A. Kokhanovsky 159.00 USD; 123.00 EUR; 103.50 GBP... More Journals » MAGAZINES & JOURNALS Water Policy - Official Journal of the World... Water Policy publishes reviews, research papers... ...
... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... More Journals » MAGAZINES & JOURNALS Journal of Water Supply: Research &Technology -... Journal of Water Supply: Research and Technolog... Environmental Quarterly - 2009 Fall Trinity`s Environmental Quarterly (EQ) magazine co... ...
... Boreal Forest and Climate Change Pertti Hari, Liisa Kulmala, 160.45 EUR; 209.00 USD; 135.00 GBP... Global Atmospheric Change and its Impact on... Ian Barnes 145.00 USD; 128.35 EUR; 95.00 GBP... More Journals » MAGAZINES & JOURNALS Journal of Water Supply: Research &Technology -... Journal of Water Supply: Research and Technolog... ...
... Boreal Forest and Climate Change Pertti Hari, Liisa Kulmala, 160.45 EUR; 209.00 USD; 135.00 GBP... More Journals » MAGAZINES & JOURNALS Journal of Water and Health The journal represents a joint commitment to pr... Environmental Quarterly - 2009 Fall Trinity`s Environmental Quarterly (EQ) magazine co... ...
BackgroundIn recent years, much attention has been given to the spread of influenza around the world. With the continuing human outbreak of H5N1 beginning in 2003 and the H1N1 pandemic...Full Text Available
This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
The heterogeneous processing of atmospheric aerosols by reaction with nitrogen oxides results in the formation of particulate and adsorbed nitrates. The water content of these hygroscopic nitrate aerosols and consequently the nitrate ion concentration depend on relative humidity, which can impact the physicochemical properties of these aerosols. This report focuses on the 310 nm photolysis of aqueous sodium and calcium nitrate solutions at pH 4 over a wide concentration range of nitrate ion concentrations representative of atmospheric aerosols. In particular, the quantum yield (phi) of nitrite formation was measured and found to significantly decrease at high concentrations of nitrate for Ca(NO(3))(2). In particular, phi for Ca(NO(3))(2) was found to have a maximum value of (7.8 +/- 0.1) x 10(-3) for nitrate ion solution concentrations near one molal, with the smallest quantum yield for the highest ...
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...
This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...
The goal of this project is to provide materials engineers, chemical engineers and plant operators with a software tool that will enable them to predict localized corrosion of process equipment including fabricated components as well as base alloys. For design and revamp purposes, the software predicts the occurrence of localized corrosion as a function of environment chemistry and assists the user in selecting the optimum alloy for a given environment. For the operation of existing plants, the software enables the users to predict the remaining life of equipment and help in scheduling maintenance activities. This project combined fundamental understanding of mechanisms of corrosion with focused experimental results to predict the corrosion of advanced, base or fabricated, alloys in real-world environments encountered in the chemical industry. At the heart of this approach is the development of models that predict the fundamental parameters that control the ...
... Materials (PREM) Synopsis of Program: The objective of PREM is to enhance diversity in materials ... careers in materials research. The Partnerships for Research and Education in Materials (PREM ...
... Materials (PREM) Synopsis of Program: The objective of PREM is to enhance diversity in materials ... careers in materials research.The Partnerships for Research and Education in Materials (PREM ...
... centers in materials research. MRSECs address fundamental materials research topics of intellectual ... in materials research. II. PROGRAM DESCRIPTION MRSECs are supported by NSF to undertake materials ...
... Materials Research - Major Instrumentation Project (IMR-MIP) program in the Division of Materials ... for materials preparation and characterization essential for researchers studying materials in a ...
... Instrumentation for Materials Research (IMR) Division of Materials Research Synopsis of Program ... for Materials Research (IMR) program in the Division of Materials Research (DMR) is designed to ...
... Materials Development Program TECHNOLOGY EDUCATION INSTRUCTIONAL MATERIALS Elementary - High School ... of technology education materials through its Instructional Materials Development (IMD) program. The ...
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ratio, air exchange rate ...
Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can therefore exclude the ...
This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, ...
Canary Islands are normally interested by dominant North-East winds that, in some meteorological conditions, can transport sand at high altitude from the Sahara desert. The dust may affect the efficiency of the telescopes and decreases the transparency of the sky. In order to maximize the scientific return of the telescopes located at the ORM, we present an analysis of the atmospheric dust content and its effects on astronomical observations. B, V and I dust aerosol astronomical extinction are derived. Using a 5 years series database of data taken from the four channel TNG dust monitor, we compute a mean hourly and daily values of the dust content. We have detected particles having size 0.3, 0.5, 1.0 and 5.0 um. Using a power law we have derived the content of 10.0 um particles. We found a typical local dust concentration ranging from 3x10^6 particles per cubic meter at 0.3 um, to 10^3 at 5.0 um and 10 at 10.0 um, increasing up to 3 order of magnitudes during the ...
... materials science and engineering, condensed-matter or materials physics, solid-state or materials ... include materials theory, condensed-matter and materials physics, solid-state and materials ...
The second international conference on containment design and operation included sessions on the following topics: performance and regulatory requirements; radionuclide behaviour; severe accident design and analysis; operation, maintenance, leaking and aging of containment systems; thermal hydraulic behaviour of containment systems; hydrogen mixing and mitigation; design methods and concepts; code validation; structural analysis and response tests; passive safety systems; aerosol behaviour; containment reliability, integrity, and risk assessment; hydrogen deflagration and detonation. Due prominence was given to CANDU and other PHWR reactors. The individual papers have been abstracted separately.
Doped ultrafine silicon dioxide powder with a narrow particle size distribution was obtained by RF discharge-stimulated dichlorosilane (SiH2C) oxidation at a low pressure using isobutylene as the combustion inhibitor and chromium hexacarbonyl (Cr(CO)6) as the dopant. The formation and morphology of the ultrafine particles are governed by the parameters of the RF discharge and by the chemical mechanism of the combustion reaction yielding the aerosol. Submicron-sized filamentous carbon structures can be obtained by isobutylene decomposition under spark discharge conditions in the presence of a molybdenum metal catalyst.
Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37 [1
The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.
The primary objective is to perform a fundamental study of filtration of nanoparticles, and to obtain filtration knowledge necessary to design particle collection devices/systems for nanoparticle processing and for preventing nanoparticle emissions into the environment. The research covered a wide area relevant to nanoparticle filtration, under these main topics: (1) nanoparticle filtration and molecular dynamics simulation, (2) nanoparticle virtual impactor, (3) particle transport under low pressure, and (4) development of a high-throughput nanoparticle generator. A number of novel tools and numerical models have been developed under the DOE support.
Models of the human airways have played a major role in evaluating the health effects of inhaled radionuclides. While models such as those of Weibel (1963) provide data necessary for characterizing deposition of aerosol, they have not characterized the cells at risks in the airspaces. Given the advancements in techniques and study of cell cultures exposed to ionizing radiation there is a need to extrapolate between the simple structures of cell culture systems and the complex architecture of the human airways. The preliminary data in this paper provide a complete characterization of the size and number of cells in the airways and represents a significant advance in our study of the health consequences of exposure to inhaled radionuclides. 26 refs., 2 figs., 4 tabs.
Thirty-two asthmatic volunteers 8 to 16 yr of age, recruited through local schools and private physicians, were exposed in a chamber to clean air (control condition) and to sulfuric acid aerosol at a low concentration (46 +/- 11 micrograms/m3; mean +/- SD) and at a high concentration (127 +/- 21 micrograms/m3). Acid aerosols had mass median aerodynamic diameters near 0.5 microns with geometric standard deviations near 1.9. Temperature was 21 degrees C, and relative humidity was near 50%. Subjects were exposed with unencumbered oronasal breathing for 30 min at rest plus 10 min at moderate exercise (ventilation rate approximately 20 L/min/m2 of body surface). A subgroup (21 subjects) were exposed similarly to clean air and to high acid (134 +/- 20 micrograms/m3) with 100% oral breathing. Increased symptoms and bronchoconstriction were found after exercise under all exposure conditions. For the group, symptom and lung function responses were not ...
We have estimated the mixing height (MH) and investigated the relationship between vertical mixing and ground-level ozone concentrations in Seoul, Korea, by using three ground-based active remote sensing instruments operating side by side: micro-pulse lidar (MPL), differential absorption lidar (DIAL), and differential optical absorption spectroscopy (DOAS). The M H is estimated from MPL measurements of aerosol extinction profiles by the gradient method under convective conditions. Comparisons of the MHs estimated from MPL and radiosonde measurements show a good agreement (r"2 = 0.99). Continuous MPL measurements with high temporal and vertical resolution reveal the diurnal variations of the MH under convective conditions and the presence of a residual layer during the nighttime. Comprehensive measurements of ozone and aerosol by MPL, DIAL and DOAS during an high ozone episode (24-26 May 2000) in Seoul, Korea, reveal that (1) photochemical ozone ...
Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged test pieces, total leak area was estimated which was smaller than ...
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.
Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...
The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...
Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.
Materials World Network: Cooperative Activity in Materials Research between US Investigators and ... Program Title: Materials World Network: Cooperative Activity in Materials Research between US ...
Materials World Network: Cooperative Activity in Materials Research between US Investigators and ... Program Title: Materials World Network: Cooperative Activity in Materials Research between US ...
This definitive reference is organized in an easy-to-follow format based on materials properties. It features new and existing data verified through major professional societies in the materials fields, such as ASM International and the American Ceramic Society. The third edition has been significantly expanded, most notably by the addition of new tabular material for a wide range of nonferrous alloys and various materials. The contents include: Structure of materials; Composition of materials; Phase diagram sources; Thermodynamic and kinetic data; Thermal properties of materials; Mechanical properties of materials; Electrical properties of materials; Optical properties of materials; Chemical properties of materials.
NSF-NIST Interaction in Chemistry, Materials Research, Molecular Biosciences, Bioengineering, and ... Laboratory (CSTL). Materials research is centralized in the Materials Science and Engineering ...
A method is described for immobilizing or solidifying waste material, which includes blending the waste material with powdered metal and subjecting the mixture of waste material and powdered metal to high pressure. (author).
... Schioler (703) 306-1836 lschiole@nsf.gov This material is available primarily for archival purposes ... of superconducting materials. Colossal magnetoresistance materials are those in which the electrical ...
... of this material is, however, outside the currently approved earth fill materials collection area ... fill material suitable for its intended use. The currently approved site contains material that is ...
The results of the thermo-hydro-mechanical (THM) study of the FEBEX bentonite performed during FEBEX II are presented. The laboratory test program continued in part with the works carried out during FEBEX I, particularly in activities related to tests aimed to the calibration of the models, the acquisition of parameters by back-analysis and the improvement of the knowledge on the behaviour of expansive clays. But the program has also included tests on new areas: investigations about the influence of the microstructure changes in bentonite, of temperature and of the solute concentration on the behaviour of clay. Besides, several tests were proposed in order to understand the unexpected behaviour observed in the mock-up test, towards the end of year 2. Temperature effects on water retention curves in confined and unconfined conditions were determined, and swelling pressure, hydraulic conductivity and swelling and consolidation strains as a function of temperature ...
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
Given the concern over the potential for health risks associated with certain ingredients (e.g., phthalates) in personal care products, usage patterns of 30 types of personal care products (e.g., shampoo, sunscreen, fragrance, etc.) were collected in 604 California households through a telephone interview. Preferences in selecting products, e.g., scented or unscented, aerosol, and brand loyalty, were also investigated. Participants were recruited in three age groups, children (mostly preschoolers), their parents, and adults age 55 or older. Use frequencies of various product types varied by sex, age group, race, education, and climatic region. Product use by parent and child from the same household were correlated. Use frequencies of products in the same class (e.g., skincare) were moderat...
A review of the ALPHA project is presented, including a summary of progress and current status. The project comprises the experimental and analytical investigation of the long-term decay heat removal phenomena from the containment of the next generation of ''passive'' Advanced Light Water Reactors. The effects of aerosols that may result from hypothetical severe accidents are also considered. The construction of the major ALPHA experimental facilities, PANDA, LINX-2 and AIDA, has been completed. First steady-state tests have been performed on PANDA. The other facilities are now in their commissioning phases. Scaling studies have guided the design of the experimental facilities. Several small-scale experimental and studies have already produced valuable results which can be used to direct the experimental work, as well as the design of the passive ALWRs. (author). 23 refs, 6 figs.
The depletion of stratospheric ozone is caused by chlorine species formed in heterogeneous processes on the surfaces of polar stratospheric cloud (PSC) particles. For studying local PSC formation processes in the Arctic a temperature lidar receiver was developed that makes use of the rotational Raman method, the only lidar technique for measuring atmospheric temperature profiles not perturbed by the presence of aerosols or cloud particles. The receiver was implemented in the mobile GKSS Raman lidar and transferred to Esrange (67.9 N, 21.1 E) near Kiruna in northern Sweden in winter 1997/98. Temperature data measured between January 22 and February 6, 1998, are presented and compared to model data analyzed by the European centre for medium-range weather forecast. Local temperature profiles are studied in three cases of type-Ib PSCs. This type is characterized by a low depolarization ratio. (orig.)
This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10"4, noble gas 2.03 x 10"4, halogen 0.13, aerosol 7.57 x 10"-"3. For "1"1"0"mAg, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997
This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny`s atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.
This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny's atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.
Possible factors regulating phytoplankton variability in the Arabian (Persian) Gulf were analyzed on the basis of satellite observations and meteorological data (1997-2009), including remotely-sensed chlorophyll a concentration (CHL), sea surface temperature, wind, solar radiation, precipitation, and aerosols. Shallow waters of northwestern Gulf influenced by Shatt Al-Arab River discharge were more productive than open Gulf waters, although seasonal CHL patterns in this and other shallow regions looked unrealistic likely because the CHL signal was obscured by bottom reflection. Therefore our further analyses focused on the open Gulf waters, which show a subtropical seasonal CHL cycle with maximum in winter and minimum in spring-summer. This cycle, however, was decoupled from the seasonal e...
The development of the monitoring network for background measurements of air pollution in the USSR is noted. The use of paired stations, to aid in locating permanent sites as well as for determining the local component of background air pollution, is described. Thermoelectric actionometers with five glass filters are used to measure Shupp's turbidity coefficient for estimating extinction of solar radiation due to aerosols. Sampling and chemical analysis of precipitation uses methods developed during the International Geophysical Year. An intercomparison of meteorological instruments was carried out in the USSR in 1973 and 1978. The most stable actinometer was the Linke-Foisner device. Chemical analyses of precipitation made since 1958 in the USSR show increases in air pollution levels only in particular areas.
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of radiation observations.
Fischer-344 rats were exposed to quartz dusts and to quartz-bearing oil shale dusts in long-term inhalation studies. Aerosol concentrations of 12 mg/m/sup 3/ and 152-176 mg/m/sup 3/ for quartz and shale dusts, respectively, were used in exposure regimens lasting up to two years. Pulmonary fibrosis was observed in most animals surviving beyond 400 days. Adenocarcinomas and epidermoid carcinomas of the lung were observed in animals from all exposure groups, including those exposed to quartz alone. The pulmonary tumors were a late effect, with the earliest lung tumor being observed after 651 days. 13 references, 10 figures, 4 tables.
Ozone plays a critical role in both the chemistry and radiation balance of the troposphere. Understanding the factors controlling tropospheric ozone levels is critical to our understanding of a variety of issues in global chemistry and climate change. Chlorine atoms have the potential to contribute significantly to the ozone balance in the free troposphere. They can react directly with ozone or alternately, with organics and may actually lead to the formation of ozone in the presence of sufficient NO. Reactions of alkali halides in sea salt particles are a potential source of atomic chlorine, hence reactions of these alkali halides, especially those producing precursors to atomic chlorine, are of great interest. Finally, the mechanisms, intermediates and products of the Cl-biogenic reactions are unknown; these could serve as unique markers of chlorine atom chemistry in the troposphere, and hence are important to define.
High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...
Spacecraft studies of the three terrestrial planets with atmospheres have made it possible to make meaningful comparisons that shed light on their common origin and divergent evolutionary paths. Early in their histories, all three apparently had oceans and extensive volcanism; Mars and Earth, at least, had magnetic fields, and Earth, at least, had life. All three currently have climates determined by energy balance relationships involving carbon dioxide, water and aerosols, regulated by solar energy deposition, atmospheric and ocean circulation, composition, and cloud physics and chemistry. This paper addresses the extent to which current knowledge allows us to explain the observed state of each planet, its planetology, climatology and biology, within a common framework. Areas of ignorance...
A highly effective and economical apparatus was developed by the All-Union Scientific Research Institute for Energy and Nonferrous Metallurgy for cleaning waste gases from cupola and electric arc steel melting furnaces --- the ''Ural'' rotoclone, which has been successfully introduced in many enterprises. Research results are presented for the efficiency of operation of these aggregates on equipping them on cupola and electric furnaces. With a 2 kPa aerodynamic resistance of the rotoclone the flue gas of the cupola furnace is cleaned to the sanitary standard. Highly effective collection of sublimates and aerosols from the electric arc furnace takes place with a ''Ural'' rotoclone aerodynamic resistance
A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.
This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...
A survey is given on the results in hand on the natural radioactivity of building materials. It is shown that only a small percentage of building materials has an increased content of radioactive materials. The results are compared with approximate values given in a Russian publication. (orig./AK).
... Highly-Functional Materials" was launched in JFY1996 under the New Materials field. This project was ... Bio-mimetic materials" (1) Advanced stimuli responsive materials (2) Harmonized molecular materials ...
... materials science and education beyond what is expected from any one Center. "Advanced materials are ... for DMR's Division of Materials Research. "Fundamental research on materials is essential to the ...
... 1995 Trilateral Materials Workshop PDF (202K) Report of the Workshop on Materials for Future ... in Materials Research Technology and Education PDF (163K) US-Asian Pacific Materials Research ...
The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol ...
Combinations of exposure concentrations, durations and frequencies were tested in four-week inhalation exposures followed by two weeks of recovery to define the interactive effects of these variables on biologic responses and to select the most-sensitive biologic response parameters for the subsequent subchronic studies. Response surface modeling was used for the experimental design and statistical analysis of the data. Results of preliminary testing suggested that exposure duration and frequency did not have major effects. Subsequently, male and female Sprague-Dawley rats were exposed in separate studies to RP/BR aerosols ranging from 0.40 to 1.20 mg/1 or to filtered air for 2.25 hr/day on four days/week for four weeks. Test-atmosphere monitoring data demonstrated that aerosol concentrations were consistently within 4% of the target values and mean particle size ranged from 0.44-0.64 ..mu..m with mean sigma g's of 1.66-1.97. During ...
This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size (MMAD 0.25 ..mu..m +- 0.1) by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of 12 2-in. scintillation detectors and two 2-in. leg counters, all coupled to single channel analyzers. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 h. When the retention data were corrected for blood-borne /sup 203/Pb, the ...
The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the experiments. At high Reynolds numbers, ...
The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the experiments. At high Reynolds numbers, ...
Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0
The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...
Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.
Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...
Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.
In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.
The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.
... Astronomy & Space Biology Chemistry & Materials Computing Earth & Environment Education ... Materials Research Center at the University of Chicago, one of nearly 30 NSF-supported Materials ...
... of Award Costs (Schedule A), are free of material misstatement. An audit includes examining, on a ... support costs, materials and supplies, and the indirect costs. We found two material internal ...
International Patenting Trends in Advanced Materials: Ceramics (June 18, 1999) This report is the ... manufacturing, biotechnology, and advanced materials. Hypertext Format Portable Document Format ...
... s guides and "how-to" videos and other materials, and 7. Receive continuing support from GLOBE's ... and educational materials that result from international proposals in its materials and support ...
As adulterated and substituted Chinese medicinal materials are common in the market, therapeutic effectiveness of such materials cannot be guaranteed. Identification at species-, strain- and locality-levels,...Full Text Available
... curricula and prototypical instructional materials have been emphasized. The program has provided ... materials are adapted and implemented on a state-wide basis. The laboratory materials and the text ...
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...
This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...
... Tokyo Report: Japanese Government Budget for Materials R&D Date: 6/17/97 The National Science ... Graded Materials Area coordinator: Dr. Toshio Hirai, Professor, Institute for Materials Research ...
... impact criterion, as demonstrated by the materials research community. These include training ... designing new materials or new processing/fabrication routes to existing materials; exploring and ...
... of new construction materials; and the behavior of infrastructure materials and structural ... polymers, reinforcing materials, wood and biodegradable structural materials; scale effects from ...
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
... and Security..........................13 Materials Science ... hybrid system theory, Internet analysis, materials science, mixing, physiology, iterative control ...
... many intriguing new possibilities in the materials sciences. Or consider solitons, a mathematical ... point out that advanced instrumentation, new materials, novel production methods, and efficient ...
As a part of DOE's Meteorological Effects of Thermal Energy Releases (METER) program a field study was undertaken at the Bowen Electric Generating Plant (Plant Bowen) in December 1979. The study was a joint endeavor of Battelle Pacific Northwest Laboratories (PNL), Pennsylvania State University (PSU), and Oak Ridge National Laboratory (ORNL) with the main objective of determining the effects of the plant's smokestack effluents on aerosol characteristics and precipitation chemistry. Other objectives included studies of cooling tower temperature and humidity (T/h) plumes and drift drop concentrations. Conducted over a period of three weeks, the study involved an instrumented aircraft, pilot balloons, a tethered balloon system, a dense network of wetfall chemistry collectors and numerous ground- and tower-based meteorological instruments. Rainfall samples collected during the precipitation event of December 13, 1979, revealed some evidence of plume ...
The role of atmospheric urea on the biogeochemical cycle of Water Soluble Organic Nitrogen (WSON) in the Eastern Mediterranean was assessed by collecting and analyzing wet and dry deposition samples and size segregated aerosols during a one year period (2006). In rain water volume weighted mean (VWM) concentration of urea was found equal to 5.5mM. In atmospheric particles the average concentration of urea in coarse and fine mode was 0.9+/-1.9nmolNm^-^3 (median 0.0nmolNm^-^3) and 2.2+/-3.0nmolNm^-^3 (median 1.1nmolNm^-^3), respectively. The percentage contribution of urea to WSON fraction was 0% and 20% in coarse and fine particles respectively. On an annual basis 0.81mmolm^-^2 and 1.78mmolm^-^2 of urea were deposited via wet and dry deposition, contributing to WSON by 10% and 11% respectiv...
On behalf of the United Nations Environment Programme (UNEP) a study has been established by the Refrigeration, Air Conditioning and Heat Pump Technical Options Committee in which famous experts of refrigeration technology compiled facts which allow for a reliable prospect of real possibilities of changing from fluorine hydrogen to ozone innoxious substitutes and substitute technologies. With regard to the organization, a division into 6 committees for the establishment of the study has been made: 1. Refrigeration Options Committee, 2. Foams Options Committee, 3. Solvents, Coatings and Adhesives Options Committee, 4. Aerosols, Sterilants and Miscellaneous Uses Options Committee, 5. Halons Technical Options Committee and 6. Economic Options Committee. (BWI).
One of the main objectives of the Finnish Research Programme on Climate Change (SILMU) has been to assess the possible impacts of future changes in climate due to the enhanced greenhouse effect on natural systems and human activities in Finland. In order to address this objective, it was first necessary to specify the types of climate changes to be expected in the Finnish region. Estimates of future climate are conventionally obtained using numerical models, which simulate the evolution of the future climate in response to radiative forcing due to changes in the composition of the atmosphere (i.e. of greenhouse gases and aerosols). However, there are large uncertainties in the model estimates because current knowledge and understanding of atmospheric processes remains incomplete. Since accurate predictions of climate change are not available, an alternative approach is to develop scenarios. These are plausible projections which reflect the best estimates to the ...
A technical review is presented of experiment activities and state of knowledge on air-borne, radiation source terms resulting from explosive sabotage attacks on spent reactor fuel subassemblies in shielded casks. Current assumptions about the behavior of irradiated fuel are largely based on a limited number of experimental results involving unirradiated, depleted uranium dioxide ''surrogate'' fuel. The behavior of irradiated nuclear fuel subjected to explosive conditions could be different from the behavior of the surrogate fuel, depending on the assumptions made by the evaluator. Available data indicate that these potential differences could result in errors, and possible orders-of-magnitude overestimates of aerosol dispersion and potential health effects from sabotage attacks. Furthermore, it is suggested that the current assumptions used in arriving at existing regulations for the transportation and storage of spent fuel in ...
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual arc welding of high alloy steels with ...
We evaluated the similarities between ozone-induced and mite-induced emission of volatile organic compounds (VOCs) from lima beans, and tested the response of the natural enemies of herbivores to these emissions using trophic system of two-spotted spider mites and predatory mites. The acute ozone-exposure and spider mite-infestation induced the emission of two homoterpenes, (E)-4,8-dimethyl-1,3,7-nonatriene and (E,E)-4,8,12-trimethyl-1,3,7,11-tridecatetraene, and (Z)-3-hexenyl acetate. Only plants with spider mite-infestation emitted the monoterpene (E)-{beta}-ocimene. Predatory mites were equally attracted to ozone-exposed and unexposed plants, but discriminated between spider mite-infested and uninfested plants, when both were exposed to ozone. The similarities between ozone and herbivore-induced VOCs suggest that plant defence against phytotoxic ozone and the production of VOCs for attraction of the natural enemies of herbivores may have adaptive coevolution. However, the expected ...
This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm{sup 2}. Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used on GCMs.
The studies reported here used genetic differences in susceptibility of C57BL/6N and C3H/HeN mice and exacerbation of the disease by nitrogen dioxide (NO/sub 2/) as tools in assessing the role of early host responses in the pathogenesis of MRM. The two strains did not differ in susceptibility to infection, but C3H/HeN mice were more susceptible to and had increased severity of lung lesions 14 days after intranasal inoculation as determined by 50% biological endpoints and morphometric analysis of tissues. Exposure to NO/sub 2/ for 4 hours prior to exposure to infectious aerosols exacerbated murine respiratory mycoplasmosis (MRM) by 7 days after exposure in both mouse strains. NO/sub 2/ appeared to affect host lung defense mechanisms responsible for limiting mycoplasmal growth in the lungs. The NO/sub 2/ exposure concentration required for this effect varied with the genetic background of the host, the dose of mycoplasmas administered, and the endpoint measured. ...
The photoelectron resonance capture ionization (PERCI) of cysteine (Cys) and small gas-phase neutral peptides that contain the Cys residue (Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)) is reported. At an ionization energy less than 1eV two types of dissociative electron attachment ionization were observed for Cys: hydrogen atom loss, resulting in formation of the ion [Cys-H]-, and dissociation of the CH2-SH bond, resulting in formation of the ion [SH]-. The presence of these ions suggests that both the p*(-CO2H) and *(C-S) orbitals can act as low energy electrophores on Cys. This ionization trend was observed for the dipeptides Cys-Gly and g-Glu-Cys as well as glutathione, with evidence that dissociation of the CH2-SH bond in these peptides can also result in ions of the form [M-SH...
The EUROTRAC sub-project ''Tropospheric Ozone Research'' (TOR) follows a dual strategy: - Observation of the chemical processes contributing to the oxygen balance directly in the atmosphere; - Establishment of a validated data base for model calculations. Both tasks require simultaneous measurements of a wide range of chemical and meteorological components. In the case of the investigation of the chemical processes, it is also desirable to measure the free radicals directly involved in ozone production. In the project described, a measuring station was set up. For a period of two years and a half, continuous measurements were made of ozone and its chemical precursors (NO, NO_2, NO_y, VOC, CO), as well as other photooxidants (H_2O_2 and organic hydroperoxides, organic nitrates), the photolysis frequency of NO_2, and meteorological parameters (wind, temperature, moisture, aerosols). The station was located on the Schauinsland mountain in the southern Black Forest, at ...
The terrestrial biosphere can significantly affect the exchange of water and energy at the biosphere-atmosphere interface. Additionally, the land cover type can affect regional atmospheric chemistry and climate via biogenic volatile organic carbon (VOC) emissions and their formation of secondary organic aerosols. The broad goal of this study is to investigate the impact of land cover and vegetation changes on these specific chemistry and climate effects. The Common Land Model (CLM) is used to parameterize the biosphere-atmosphere interface over the Shanghai region in China. Phase 1 of this study, described in this report, generates input parameters for this model based on a time series of actual and derived parameters. Atmospheric forcing data are generated on an hourly temporal resolution based on a 20-year series of monthly and daily averages. Surface data, including land cover/land use and soil information, are generated for two scenarios: (a) the current land ...
Hydrolysis of olive oil by Chromobacterium viscosum lipase was studied in a reverse micellar system of a anionic surfactant Aerosol OT (AOT) and isooctane. Different methods of solubilization of the micellar system afford specific dependence of enzymatic activity of the lipase on the water content in the micelles. In an injection method, water content is controlled by the amount of injected water, which determines the micelle size and hydrophobicity of the micelle without salt addition and changes reversibly the conformation of lipase corresponding to the change of lipase activity. The activity reaches the maximum at a water content (water/AOT)of 7. In a phase transfer method, water content is determined by salt concentration in the aqueous phase in contact with micelles and the water content corresponding to the maximum activity is 12 to 13, below which the activity decrese drastically. Addition of taurodeoxycholic acid to the AOT micelles suppresses the ...
Beagle dogs given a single exposure to "2"3"9PuO_2 or "2"3"8PuO_2 aerosols are being observed for life-span dose-effect relationships. The "2"3"9Pu body burden of the nine dogs that died of pulmonary fibrosis-induced respiratory insufficiency during the first 3 yr after exposure was 1 to 12 #mu#Ci. One of these dogs had a pulmonary tumor. Five additional dogs with body burdens of 0.7 to 1.8 #mu#Ci died due to pulmonary neoplasia 3 to 5 yr after exposure. None of the dogs exposed to "2"3"8Pu have died during the first 3 postexposure yr. Lymphocytopenia was the earliest observed effect after inhalation of "2"3"9PuO_2 or "2"3"8PuO_2, occurring 0.5 to 2 yr after deposition of greater than or equal to 80 nCi plutonium in the lungs.
Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.
The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying levels.
The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined measurements of the field of atmospheric temperature and ...
A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga{sup +} ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.
A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga"+ ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.
A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was calibrated with ...
The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the features and performance of the models ...
The objectives of this study were to estimate symbiotic nitrogen fixation by two common pasture legumes, Trifolium subterraneum L. and Medicago truncatula Gaertn., and an Australian native legume, Acacia dealbata Link, growing in pots using an indirect isotopic method. This method was also used to calibrate the C2H2 reduction assay of the intact plants. In addition, hydrogen evolution was measured in an attempt to explain the variations in C2H2:N2 ratios between the species. 25 refs.; 1 figure; 4 tabs.
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
The sequence of events from the assembly of a space nuclear power system to its integration in the Space Shuttle Transportation System (STS) is considered. First, the sequence followed for SNAP-10A, the only free world space reactor electric power system ever launched and operated in space, is reviewed. Before shipment, the SNAP-10A reactor was raised to operating temperature using electrically supplied heat and operated at low power for control calibration. Next we discuss shipment to the launch site, a phase that is critical because of the potential for various accidents. Once the power system arrives at the launch site, the processing sequence is performed. This sequence includes checkout, mating with the payload or upper stage launch vehicle, and integration into the STS.
A distributed watershed hydrologic model soil and water assessment tool (SWAT, 2000 Version) was applied to simulate stream flow and nutrient loadings (including total nitrogen (TN) and total phosphorus (TP)) in Gucheng Lake Basin, which is located in the lower reach of Yangtze River Basin. Model parameters related to stream flow and nutrient loadings were calibrated and validated by the observed value, and the simulation showed that the simulated values were reasonably comparable to the observed data, suggesting the validity of SWAT model. The simulated surface runoff and nutrient yield between two stages, viz. 1981-2000 and 1951-1960, were compared, basically considering land reclamation in the mid-1970s. The result indicated that, the average annual runoff and output of TN and TP in 198...
In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
The theory of a method of determination of the reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mock-up of a liquid-metal fast breeder reactor and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mock-up, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies, to approximately 30 dollars subcritical.
The general objective of this workshop is to investigate and discuss methods by which uncertainties in mass balance models for toxics in the Great Lakes may be reduced. As described by the workshop prospectus, this paper is focused on problems of reducing (and quantifying) uncertainty as they relate to in situ field observations/system response measurements for the establishment of initial conditions, boundary conditions, calibration/confirmation data sets, and model post-audit data sets.'' I have taken this description to refer not only to the evaluation of uncertainty in the field observations themselves, but also to the uncertainty associated the analyses of in situ observations as they interact in the overall modeling process. Thus, I will be concerned here with quantification and reduction of uncertainty both (1) as they may be applied to descriptions of the system that is being modeled and (2) as they may be associated with model ...
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...
Two natural gas/diesel dual fuel conversion systems for the Detroit Diesel 6V-71 transit bus engine were described. The basic concept of a dual fuel engine was to operate a diesel engine with both liquid fuel injection and a lean premixed gas mixture. The engine achieved high efficiency due to the high compression ratio typical of the diesel engine. Test results were obtained using three different calibrations on one engine. The objectives were to match existing engine performance with improved emissions and better overall fuel economics. Results showed that overall, engine conversion has both economic and emissions advantages over a straight diesel engine. However, the durability and in-use applicability of the system remains to be demonstrated with an in-bus demonstration project.. 3 tabs., 4 figs.
The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...
The use of numerical modeling in oil spill incidents is a well established technique that has proven to provide cost-effective and reasonable estimates of oil surface drift. Good predictability of such models depends highly on the quality of the input data of the incident and on the model calibration effort. This paper presents the results of simulating oil spillage trajectory in the Arabian (Persian) Gulf. The study employed a 3-D rectilinear hydrodynamic model combined with oil spill model. Typical representative environmental conditions of the Arabian Gulf were first setup into a hydrodynamic circulation model using data from various sources. The performance of the hydrodynamic model was then tested against measurements of tidal fluctuation and sea currents at selected locations. The sp...
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.
This report gives a brief introduction to the project `Probabilistic Design Tool for Wind Turbines` - PRODETO - which was carried out during the years 1996-98 with partial funding from the European Commission under the Non-Nuclear Energy Programme JOULE III. The report gives an overview of the objectives and motivation for the project, and the methodology used. In this context, an example of reliability-based wind turbine design against fatigue failure is outlined with emphasis on the various important steps herein, which include probabilistic load and resistance modelling, calculation of failure probability, and calibration of partial safety factors for use with a deterministic design code format. The results of the project are presented with emphasis on a developed computer program and its capabilities, and the various elements of an executed case study are outlined. A list of project reports concludes the report. (au)
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise ...
The preparation and luminescence properties of crystal phosphors based on alkali metal iodide and calcium oxide substrates were studied. The highest luminescence intensities were achieved with iodide substrates at 200/sup 0/ and with the calcium oxide substrate at 800/sup 0/. The calibration graphs were linear in the thallium concentration ranges 0.03-5.0 and 0.1-2.0 mu g using sodium and potassium oxides, respectively, and in the range 0.05-5 mu g using cesium iodide and calcium oxide. A method is proposed for the determination of down to 3 x 10/sup -4/% thallium in rocks, using a crystal phosphor with sodium iodide substrate.
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which gives rise to a medical ...
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...
In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
The Cycle 8A static tests conducted in the Fast Flux Test Facility (FFTF) during 1986 have resulted in the separation of various feedback reactivity components. These feedback components, described by closed-form equations depending only on the reactor temperature field, can be regarded as database for the validation and/or calibration of feedback mechanistic models. The SASSYS safety analysis code contains the most developed feedback reactivity models and was selected for the comparison study between database and mechanistic calculations for the FFTF. Although detailed feedback models for control rod repositioning and core radial expansion/bowing exist, only the simple models were available in SASSYS at the time of this study. The results are described in this paper.
The Jeanne d`Arc Basin is located 320 km offshore in the Grand Banks of Newfoundland. It is a Mesozoic failed-rift basin with recoverable oil reserves of about 2 billion barrels. Its huge Hibernia Field will be in production by late 1997. The basin has been reappraised using sequence stratigraphic concepts, and renewed exploration in the area is expected. The Upper Jurassic - Lower Cretaceous sedimentary accumulation in the Basin was formed by the extensional tectonics that created the North Atlantic Ocean. The sedimentary packages were placed in chronostratigraphic order by calibrating the biostratigraphy of the Oxfordian to Maastrichtian section to the detailed ammonite zonation from the North Sea.
The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous ...
This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.
In view of no satisfactory mathematical model is presently available for the dose-response curve of immunoradiometric assay, a three parameter model based on single binding site mass action law has been derived. A curve fitting method based on similar principle of linear robust regression was designed and a software was prepared for use on IBM personal computers. Experiments revealed that the model is applicable to a variety of IRMA systems as well as to time-resolved immunofluorometric assay of hAFP. When there was outlier(s) of the calibration curve, the average bias of unknown samples obtained with this method is significantly smaller than methods using four parameter logistic model or four parameter single site mass action model.