WorldWideScience
1

Calibration of the solar UV radiometers in Finland  

Energy Technology Data Exchange (ETDEWEB)

In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

1996-12-31

2

Automated radon radiometers of RRA family  

Energy Technology Data Exchange (ETDEWEB)

Two automated radiometers of RRA family designed for radon concentration measurements are presented. Principal performance specifications and promising applications of the radiometers are presented.

1999-08-01

3

Radiometric measurement of temperature distributions in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...

1989-03-01

4

THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA  

Science.gov (United States)

tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...

5

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR ...

2011-03-14

6

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the ...

2010-07-26

7

VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:  

Science.gov (United States)

0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...

8

Mission Science Calibration and Validation Plan - SMAP  

Science.gov (United States)

Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...

9

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

10

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the ...

1997-04-01

11

Intercomparison of irradiance measurements based on WRR and ETL irradiance scales  

Energy Technology Data Exchange (ETDEWEB)

We report the corrected intercomparison of the World Radiometer Reference (WRR) irradiance scale and the Electrotechnical Laboratory (ETL) spectral irradiance scale. In addition, we confirm the intercomparison precision using the test facility where the irradiance of ETL 500 W standard lamp can be measured directly with the cavity radiometer. The results showed that the irradiance based on the WRR scale was 0.5-0.7% lower than the one based on the ETL scale

1997-10-14

12

Sigma-Point Kalman Filter Based Sensor Integration ...  

Science.gov (United States)

... is the extended Kalman filter (EKF ... Kalman filters called sigma-point Kalman filters ... INFERENCE, *KALMAN FILTERING, *DRONES, *SITUATIONAL ...

2004-10-25

13

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

14

NASA Surfs the Skies Above Oahu, Hawaii  

National Aeronautics and Space Administration (NASA)

This flyover of the Hawaiian island of Oahu was made by draping Jan. 13, 2010, image data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra spacecraft over new ASTER Version 2 digital elevation data.

2011-10-17

15

Comparison of Soil Surface Temperature Measurements by Means of Standard Soil Mercury Thermometers and a Barnes Prt-5 Infrared Thermometer.  

Science.gov (United States)

A short account is given of the difficulties encountered in temperature measurement of boundary layers and a comparison of two types of thermometers, an infrared radiometer and mercury in glass thermometer. (Author)

1972-01-01

16

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

17

The Hubble Space Telescope Wide Field Camera 3 Early Release Science Data: Panchromatic Faint Object Counts From 0.2-2 Micron To Ab=26-27 Mag  

Science.gov (United States)

We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the GOODS-South field. The new WFC3 ERS data provide calibrated, drizzled mosaics with FHWM=0.07--0.15" in the near-UV (filters F225W, F275W, and F336W) and near-IR (F098W, F125W, and F160W) in typically 2 orbits per filter. Together with the existing HST/ACS GOODS-S mosaics in the BVi'z' filters, the 10-band ERS data cover 40-50 sq. arcmin to AB=26-27.0 mag (10-sigma for point sources). In this poster, we describe the: (1) scientific rationale, data taking and reduction procedures of the WFC3 ERS mosaics; (2) object cataloging and star-galaxy separation techniques used in these 10 different filters; (3) reliability and completeness of the 10-band object catalogs from the ERS mosaics; (4) object counts in 10 different filters from 0.2-1.7 microns ...

2010-01-01

18

Dead-time calibrator  

International Nuclear Information System (INIS)

... interval analyzers counting techniques discriminators electronic circuits

21

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without ...

2008-11-19

22

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full ...

2009-05-26

23

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery ...

1998-01-16

24

Experimental control of a cupola furnace  

Energy Technology Data Exchange (ETDEWEB)

In this paper the authors present some final results from a research project focused on introducing automatic control to the operation of cupola iron furnaces. The main aim of this research is to improve the operational efficiency and performance of the cupola furnace, an important foundry process used to melt iron. Previous papers have described the development of appropriate control system architectures for the cupola. In this paper experimental data is used to calibrate the model, which is taken as a first-order multivariable system with time delay. Then relative gain analysis is used to select loop pairings to be used in a multiloop controller. The resulting controller pairs melt rate with blast volume, iron temperature with oxygen addition, and carbon composition with metal-to-coke ratio. Special (nonlinear) filters are used to compute melt rate from actual scale readings of the amount of iron produced and to smooth the temperature ...

1998-08-01

25

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...

2008-07-01

26

Desensitized Optimal Filtering and Sensor Fusion Tool Kit  

Science.gov (United States)

Sep 18, 2009 ... It is proposed to develop desensitized optimal filtering ... in robust and/or adaptive generalized Kalman and Sigma-Point filters for ...

27

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document ...

2009-11-01

28

Network Security Defense Tools  

Science.gov (United States)

Lecturo on Firewalls, VPNs, Intrusion Detection, and filters

2009-02-11

29

Uncertainty analysis of high altitude aircraft air mass zero solar cell calibration  

Energy Technology Data Exchange (ETDEWEB)

Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.

1997-12-31

30

Merged Sounding Value-Added Product  

Energy Technology Data Exchange (ETDEWEB)

The Merged Sounding value-added product (VAP) uses a combination of observations from radiosonde soundings, the microwave radiometer (MWR), surface meteorological instruments, and European Centre for Medium-Range Weather Forecasts (ECMWF) model output with a sophisticated scaling/interpolation/smoothing scheme in order to define profiles of the atmospheric thermodynamic state at one-minute temporal intervals and a total of 266 altitude levels.

2010-03-03

31

Gastrin releasing peptide (GRP) receptor targeted radiopharmaceuticals: A concise update  

Energy Technology Data Exchange (ETDEWEB)

The gastrin releasing peptide (GRP) receptor is becoming an increasingly attractive target for development of new radiolabeled peptides with diagnostic and therapeutic potential. The attractiveness of the GRP receptor as a target is based upon the functional expression of GRP receptors in several tumors of neuroendocrine origin including prostate, breast, and small cell lung cancer. This concise review outlines some of the efforts currently underway to develop new GRP receptor specific radiopharmaceuticals by employing a variety of radiometal chelation systems.

2003-11-01

32

S-shaped magnetic macroparticle filter for cathodic arc deposition  

Energy Technology Data Exchange (ETDEWEB)

A new magnetic macroparticle filter design consisting of two 90{sup o} filters forming an S-shape is described. Transport properties of this S-filter are investigated using Langmuir and deposition probes. It is shown that filter efficiency is product of the efficiencies of two 90{sup o} filters and the deposition rate is still acceptably high to perform thin film deposition. Films of amorphous hard carbon have been deposited using a 90{sup o} filter and the S-filter, and macroparticle content of the films are compared.

1996-04-01

33

PERFORMANCE CHARACTERISTICS OF AN ...  

Science.gov (United States)

... Abstract : A COMMERCIALLY AVAILABLE CAMOO4 TUNABLE ACOUSTO- OPTIC FILTER HAS BEEN ... OF THE FILTER CAN BE SWITCHED IN 20 ...

1976-05-01

34

Partially-carbonized polyacrylonitrile filter  

Energy Technology Data Exchange (ETDEWEB)

A filter for extracting solids and liquids from gaseous combustion exhausts comprises a textile filter element formed of polyacrylonitrile fibers oxidized by careful heat treatment and comprising approximately 61% carbon after treatment. The filter may be woven, knitted or formed as a batting of randomly-oriented fibers. Abrasion resistant coatings and lubricants for the fibers are disclosed. The filter material is especially useful as a filter bag.

1984-04-24

35

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

36

Estimation of half-life values of actinide radionuclides  

International Nuclear Information System (INIS)

... actinides americium 241 americium 242 americium 243 calibration standards

1986-04-15

39

Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator  

CERN Document Server

The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

2002-01-01

40

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

41

lib_general.pro - ECCO2  

Science.gov (United States)

Returns singular values (sigma), ;left field (x) vectors, ..... n) do begin point=ngbrs(i) if (point+tau le nt-1) then begin if (x(point+tau,0) ne q) then .... ;FILTER ;applies a gaussian filter in the frequency domain function filter, x ...

42

ENVI Reference Guide - NASA  

Science.gov (United States)

ADD_MEAN is a floating point number. This value is only used for the LEE filter, ... an averaging filter. This value is only used for the Frost filter, ...... Use this keyword to specify the gaussian sigma value for methods 4 and 5. For ...

43

Decontamination factor of air filter against /sup 198/Au aerosol particles  

Energy Technology Data Exchange (ETDEWEB)

DF (decontamination factor) of two types of air filter was investigated against /sup 198/Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 ..mu..m and sigmag (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mmphi, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mmphi. DF of the SO filter was found to be over 5 x 10/sup 4/ at air flow rate of 1 lmin. And DF of HE-40 T filter was determined to be 94+-4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each ...

1987-12-01

44

Decontamination factor of air filter against "1"9"8Au aerosol particles  

International Nuclear Information System (INIS)

DF (decontamination factor) of two types of air filter was investigated against "1"9"8Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 #mu#m and #sigma#g (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mm#phi#, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mm#phi#. DF of the SO filter was found to be over 5 x 10"4 at air flow rate of 1 l/min. And DF of HE-40 T filter was determined to be 94#+-#4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each ...

45

Tightly-Coupled Image-Aided Inertial Navigation Using the ...  

Science.gov (United States)

... The unscented "sigma-point" Kalman filter "UKF ... set of carefully chosen sample points. ... Descriptors : *KALMAN FILTERING, *INERTIAL NAVIGATION ...

46

The determination of particulate contamination in miniature ball bearings  

Energy Technology Data Exchange (ETDEWEB)

A method is described for determining the particulate contamination in miniature ball bearings in which the bearing is flushed with a solvent that is then filtered. The particles that are collected on the filter are examined by optical microscopy.

1992-12-01

47

Radiological Source Localisation  

Science.gov (United States)

... The goal of filtering (the sequential Bayesian ... 5] and the unscented Kalman filter (UKF) [16 ... set of deterministically chosen sample (or sigma) points. ...

2007-07-01

48

Filtered Density Function for Subgrid Scale Modeling of ...  

Science.gov (United States)

... Compilation Part Notice ADP023645 TITLE: Filtered Density Function for Subgrid Scale Modeling of Turbulent Diffusion Flames ...

2006-06-01

50

Condition Monitoring of Aircraft by Quantitative Filter Debris ...  

Science.gov (United States)

... 15- Two Sigma from Mean S..... I ..... 2 ... only a small number of engine filter debris samples ... comprehensive, but it does point out that ...

1996-04-01

51

COMPARING CONSIDER-COVARIANCE ANALYSIS WITH SIGMA-POINT CONSIDER ...  

Science.gov (United States)

As presented in [4], the Sigma-Point Consider Filter (SPCF) algorithm extends ... lines of the derivative-free, Sigma-Point Kalman Filter algorithm given in ...

52

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is described for measuring the overall decontamination factor of first and second filters, the first and second filters being located in a plenum having an upstream chamber, an intermediate chamber, and a downstream chamber. The first filter is located between the upstream and intermediate chambers and the second filter is located between the intermediate and downstream chambers. The apparatus comprises a. an aerosol generator for producing a challenge aerosol composed of individual particles, the aerosol generator being in fluid communication with the upstream chamber; b. an upstream collector for collecting the challenge aerosol before the challenge aerosol enters the first filter, the upstream collector being disposed in the upstream chamber; c. an intermediate collector for collecting the challenge aerosol that passes through the first filter, ...

1986-10-28

53

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol ...

1985-07-03

54

An Extended Kalman Filter for Use in a Shared Aperture ...  

Science.gov (United States)

... used to track a point source target ... A one sigma tracking error of .2 ... LOOKING INFRARED SYSTEMS, *KALMAN FILTERING, SIGNAL PROCESSING ...

1978-12-01

55

The calibration of sub-Coulomb heavy ion proton transfer reactions  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si systems was collected to provide ...

1987-01-01

56

Feedback control of a cupola - concepts and experimental results  

Science.gov (United States)

In this paper we present some final results from a research project focused on introducing automatic control to the operation of cupola iron furnaces. The main aim of this research is to improve the operational efficiency and performance of the cupola furnace, an important foundry process used to melt iron. Previous papers have described the development of appropriate control system architectures for the cupola. These results are summarized. Then we describe the experimental results obtained with the U.S. Department of Energy Albany Research Center`s research cupola. First, experimental data is used to calibrate the model, which is taken as a first-order multivariable system with time delay. Then relative gain analysis is used to select loop pairings to be used in a multi-loop controller. The resulting controller pairs meltrate with blast volume, iron temperature with oxygen addition, and carbon composition with percent coke. Special (nonlinear) ...

1998-10-01

57

Experiments in High-Frequency Imaging of the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We attempt to image the rupture propagation of the 2004 M6.0 Parkfield earthquake by analyzing records from the USGS Parkfield seismic array (UPSAR) and other strong-motion stations. The UPSAR array consists of 12 stations distributed over about one square kilometer at a distance of 10~km from the San Andreas fault near Parkfield, California. We employ a method that uses reverse time migration to stack the seismograms at back-projected locations along the fault. We use waveform cross-correlation to align the initial P-wave arrivals and correct for small static time shifts in the records. This forces a coherent image at the hypocenter at the quake origin time. Initial results at later time steps show some evidence of the expected rupture propagation to the north. However, the resolution of the back-projection is limited by the small aperture of the UPSAR array. Records from other strong-motion stations can improve the theoretical resolution kernels but are less coherent among records ...

2006-12-01

58

ALOS satellite imagery utilizations for safeguards  

International Nuclear Information System (INIS)

This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 degrees, 691.65 km ...

2006-10-16

59

Fast Wire Scanner Calibration  

CERN Document Server

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...

2009-01-01

60

"Advanced" data reduction for the AMBER instrument  

CERN Document Server

The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...

2008-01-01

63

Mathematical two-dimensional model for three-phase filtering of compressible fluids  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model is proposed for three-phase filtering which is a particular case of a more general model of filtering multiple component mixtures and makes it possible to describe three-phase filtering flows under conditions where the pressure of saturation is variable in time and in space. In the proposed model, the system of unknown functions is selected so that it makes it possible to trace fairly simply the pressure of saturation and to compute the corresponding equation coefficients.

1982-01-01

65

Continuous flow dielectrophoretic particle concentrator  

Energy Technology Data Exchange (ETDEWEB)

A continuous-flow filter/concentrator for separating and/or concentrating particles in a fluid is disclosed. The filter is a three-port device an inlet port, an filter port and a concentrate port. The filter separates particles into two streams by the ratio of their dielectrophoretic mobility to their electrokinetic, advective, or diffusive mobility if the dominant transport mechanism is electrokinesis, advection, or diffusion, respectively.Also disclosed is a device for separating and/or concentrating particles by dielectrophoretic trapping of the particles.

2007-04-17

67

Clinoptilolite filter for the removal of tritiated water vapour  

International Nuclear Information System (INIS)

The removal of tritiated water vapour was tested by use of a small burning apparatus and a clinoptilolite filter. It was found that decontamination factor of about 10"4 could be obtained by a clinoptilolite filter. The adsorption of HTO in the clinoptilolite is caused by the diffusion, so it is necessary that filtration velocity is maintained below 0.01 m/sec. Decontamination factor was not influence by the moisture content of a clinoptilolite and tritiated water vapour once adsorbed on a filter was hardly removed. (auth.).

68

Barrier filter for fluorescence microscopy of strongly autofluorescent plant tissues. Application to actin cables in Chara.  

Science.gov (United States)

A liquid barrier filter for use in fluorescence microscopy of strongly autofluorescent plant tissues is described. The filter consists of a methanol solution of cupric chloride and ferric chloride and isolates fluorescein fluorescence from the strong red autofluorescence of photosynthetic plant tissues. Subcortical actin cables in the giant alga Chara are being visualized through use of this filter together with heavy meromyosin labeling. PMID:90068

1979-05-01

69

Decontamination factors of ceramic filter in radioactive waste incineration system  

International Nuclear Information System (INIS)

A suspension-firing type radioactive waste incineration system is developed and cold demonstration testing of ceramic filters for the system are carried out. The incineration system, which is useful for a wide variety of waste materials, can serve to simplify the facilities and to reduce the costs for waste disposal. The incineration system can be used for drying-processing of concentrated waste liquids and disposal of flame resistant materials including ion exchange resins and rubber, as well as for ordinary combustible solid materials. An on-line backwash system is adopted to allow the ceramic filters to operate stably for a long period of time. For one-step filtering using the ceramic filter, the decontamination factor is greater than 10"5 for the processing of various wastes. In a practical situation, there exist vapor produced by the spray drier and the cladding in used ion exchange resin, which ...

70

HPA - Radon Calibration Facilities  

Wastenet

... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...

71

Design Calibration and Field Use of a Stomatal Diffusion Porometer  

UK PubMed Central (United Kingdom)

Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available

1969-06-01

72

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Function of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.

2009-06-17

73
74

Development and Calibration of Two and Four Wire Water ...  

Science.gov (United States)

... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...

1992-12-01

75

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

76

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption ...

1976-05-21

77

Iron Aluminide Hot Gas Filters  

Energy Technology Data Exchange (ETDEWEB)

Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide ...

1996-12-31

78

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...

2003-04-08

79

Monitoring transplanting operation of rice crop using passive microwave radiometer data  

British Library Electronic Table of Contents (United Kingdom)

This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...

2011-01-01

80

Hyperspectral remote sensing for mineral exploration in Pulang, Yunnan Province, China  

British Library Electronic Table of Contents (United Kingdom)

The launch of the first spaceborne hyperspectral instrument, Hyperion, in 2000 has provoked further research into its capabilities with regard to mineral exploration. Our study in the remote, mountainous region of Pulang, China employed a two-step progressive approach, first to locate target areas characterized by hydrothermal mineral alteration, using the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and secondly, to attempt detailed mineral mapping using Hyperion. The preliminary target detection involved principal components and broad-band spectral analysis and led to the detection of two target areas characterized by argillic alteration, iron-oxide- and sulphate-bearing minerals. A focused hyperspectral study followed using Spectral Angle Mapper (SAM) and Mixt...

2011-01-01

81

Evaluation of soil moisture derived from passive microwave remote sensing over agricultural sites in Canada using ground-based soil moisture monitoring networks  

British Library Electronic Table of Contents (United Kingdom)

Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...

2010-01-01

82

C-106 tank process ventilation test  

Energy Technology Data Exchange (ETDEWEB)

Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air filter and housing to the recirculation system. This configuration would eventually ...

1998-07-20

83

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) ...

1994-10-01

84

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) ...

1994-01-01

85

TO: All GCN Notice recipients RE  

Science.gov (United States)

These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...

86

Swift Science Center - HEASARC - NASA  

Science.gov (United States)

Apr 20, 2009 ... "YY" is the 2-digit filter identifier .... In our example you can see a point- like optical/UV source in each of the filters at the ... The "sigma" paramter gives the detection threshold in terms of Gaussian sigma. ...

87

Stations Maidanak2  

Science.gov (United States)

Identification of the Ranging System Reference Point (SRP) ... Daylight Filter Type : (SPECTRAL FILTER/FABRY-PEROT/etc) Dayl. Filt. ... INT/etc) Edit Criterion 1st Chain : (ITERATIVE n.n SIGMA/MANUAL/NONE/etc) Edit Criterion 2nd Chain ...

88

Stations Maidanak1  

Science.gov (United States)

Identification of the Ranging System Reference Point (SRP) ... Daylight Filter Type : (SPECTRAL FILTER/FABRY-PEROT/etc) Dayl. Filt. ... INT/etc) Edit Criterion 1st Chain : (ITERATIVE n.n SIGMA/MANUAL/NONE/etc) Edit Criterion 2nd Chain ...

89

Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI  

UK PubMed Central (United Kingdom)

A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available

1998-04-14

90

Light amplifier with filtering of spontaneous background  

Energy Technology Data Exchange (ETDEWEB)

A comparitive analysis is made of the principal characteristics of narrow-band and conventional semiconductor light amplifiers. It is shown that quasi-distributed filtering of the spontaneous radiation ensures a high gain and a low level of the spontaneous noise at the amplifier output.

1980-06-01

91

Comparison of membrane filters for recovery of legionellae from water samples.  

UK PubMed Central (United Kingdom)

The procedure currently used for isolating legionellae from environmental samples recommend filtration through a 0.2-microns-pore-size polycarbonate filter. In this study we evaluated the performance...Full Text Available

1993-01-01

92

40 CFR 63.322 - Standards.  

Science.gov (United States)

...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...

2009-07-01

94

The Ames Stereo Pipeline:  

Science.gov (United States)

In application, there is also a little filtering of the tie points with RANSAC .... Sets the multiplier that is used to adjust the sigma (or uncertainty) of ...

95

Sidelobe Suppression in an Acousto-Optic Filer with a Raised ...  

Science.gov (United States)

... Abstract : The acousto-optic filter (AOF) is ... for large switch networks. ... FOURIER TRANSFORMATION, OPTICAL SWITCHING, SURFACE ACOUSTIC ...

1992-04-01

96

Photopolymer Holographic Optical Elements  

Science.gov (United States)

... The re-emergence of holographic photopolymers in the 1980's created an interest as to the cause of holographic notch filter instability. ...

1987-06-01

98

Optical Processing and Control  

Science.gov (United States)

... the application of an acousto- optical tunable filter ... Couplers for Large Switch-Array Applications ... Symmetric Integrated Optic X Junction," Electronics ...

1994-01-01

99

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

100

Ensemble Forecasting with the Ensemble Transform Kalman ...  

Science.gov (United States)

... of these points corresponds to the ( " 2) term in ... (d) is identical to the 1-sigma ellipse corresponding ... A new approach to linear filtering and predicted ...

2004-08-01

101

Enabling Lightwave Electronics with Nanotechnology ...  

Science.gov (United States)

... Acousto-optic programmable dispersive filters (AOPDF) have been developed for optical signal processing, polarization switching in lasers, and ...

2011-03-29

102

Decontamination factor determination for adsorption filters in nuclear power plants  

International Nuclear Information System (INIS)

Slovak 1985. p. 110-111. Czechoslovakia Moravek, J. Pietrik, I. Janecka,

1985-08-26

103

Damping of capacitance voltage substations ferroresonance using a suitable RLC filter  

Energy Technology Data Exchange (ETDEWEB)

The underlying theory and model of capacitive voltage substations and its associated problems are described. This system is intended to supply electricity to rural communities directly from high-voltage transmission lines. This technique leads to important cost reductions when compared with conventional alternatives. However, in several transient cases, some problems such as ferroresonance and overvoltages could occur in these substations. Using a developed capacitive substation model these transient cases are simulated. A suitable filter is designed to damp overvoltages clue to ferroresonance. Analytical aspects of filter design are presented and some computer simulation tests are provided to highlight the usefulness of the proposed filter. (author)

2004-11-01

104

Absorbent for removal of heavy metal impurities from gases and its production  

Energy Technology Data Exchange (ETDEWEB)

This is an adsorbent for removal of heavy metal impurities from gases. In addition to activated charcoal and ferric chloride, it contains a nonwoven dacron filter material to increase the purification level. The filter material has the following mass % composition: 27-54 activated charcoal, 7-35 ferric chloride, the remainder dacron filter material. The activated charcoal is applied to the dacron filter and the resulting mixture is treated with a ferric chloride solution. The activated charcoal is applied in the form of a suspension with a particle diameter of 0.1-0.16 mm. The treatment solution is 3-20% ferric chloride.

1981-03-23

105

A Kalman Filter Clock Algorithm for Use in the Presence of ...  

Science.gov (United States)

... Following the application of the error covariance update equation, we apply the following operation to the parameter covariance matrix P+: ...

2004-09-01

106

Variosorb - advanced gas sorption with powder sorbent technology  

Energy Technology Data Exchange (ETDEWEB)

In contrast to plants based on formed coal where, for the purposes of calculating sorbent volume, only one activated charcoal design can be used in a filter layer, powder sorbent technology enables two variations to be used. This can be either a mixture of a number of different activated charcoal forms in one and the same filter layer, or the combination of a number of filter layers on top of each other, each containing a different activated charcoal form, in one and the same construction unit.

1983-01-01

107

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

108

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...

1999-07-01

109

Signal simulator for the calibration of eddy current probes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.

1994-01-01

110

Continuous measurement of blast-furnace coke moisture  

International Nuclear Information System (INIS)

After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).

111

Calibration system for spot welding robots in offline-teaching; Offline teaching ni okeru spot yosetsu robot yo calibration system  

Energy Technology Data Exchange (ETDEWEB)

Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)

1999-04-01

112

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

113

Process for the manufacture of a filter material for cleaning industrial or internal combustion engine exhaust gases and filter material manufactured according to the process. Verfahren zur Herstellung eines Filterstoffes zur Reinigung von industriellen oder Brennkraftmaschinen-Abgasen und ein hiernach hergestellter Filterstoff  

Energy Technology Data Exchange (ETDEWEB)

This is a process for the manufacture of a filter material for cleaning industrial or internal combustion engine exhaust gases and filter material manufactured according to the process. The filter material is manufactured from the mineralized combustion product of peel of tropical fruits burnt at a temperature of 820/sup 0/C to 840/sup 0/C in an oxidising atmosphere excluding the production of carbon, particularly using banana skins and orange peels, which product is granulated with carrier materials or compressed.

1986-01-02

114

A method for producing a filtering material for organic substances  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for making a filtering material (FM) through applying bitumen or tar to a porous substance and subsequent roasting. Blast furnace slag, pumice and other inorganic substances are used as the porous substance. The method makes it possible to acquire an inexpensive filtering material with a developed surface (Pv), which replaces activated charcoal. Example. Blast furnace slag is heated to 200 to 300 degrees and with mixing is impregnated by 5 to 15 percent bitumen or tar. The impregnated slag is roasted at 800 to 1,000 degrees until full carbonization of the bitumen or tar, acquiring in this way a filtering material, which is characterized by a specific surface of 700 to 1,000 square centimeters per gram and suitable as a replacement for activated charcoal for removing organic components and heavy metals from gaseous and liquid phases. The cost of the filtering material is one eighth ...

1981-06-27

115

Tests of the ONERA Calibration Models in Three Transonic ...  

Science.gov (United States)

... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...

1976-11-01

116

Stability of modulation transfer function calibration of surface profilometers using binary pseudo-random gratings and arrays with nonideal groove shapes  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.

2010-03-31

117

Satellite Calibration Data. Annual Data Report - 1977  

Science.gov (United States)

... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...

1979-08-01

118

Salt Lake City shows hot and cold spots - NASA ... - Science@NASA  

Science.gov (United States)

Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...

119

LBA Calibrator Survey - NASA  

Science.gov (United States)

Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...

120

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...

121

DMSP Special Sensor Microwave/Imager Calibration ...  

Science.gov (United States)

... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...

2011-05-14

122

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

123

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

124

Calibrating Cosmological Chronometers: White Dwarf Masses ...  

Science.gov (United States)

... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...

2011-05-14

125

BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)  

Science.gov (United States)

replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...

126

AGARD Flight Test Techniques Series. Volume 1. Calibration ...  

Science.gov (United States)

... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...

1983-09-01

127

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

British Library Electronic Table of Contents (United Kingdom)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...

2007-01-01

128

Experiences in radioactive gaseous effluent management in JAERI  

International Nuclear Information System (INIS)

In the Japan Research Reactor-II (JRR-2), the main source of _4_1Ar generation is the exhaust air from the horizontal experimental holes and the pneumatic tubes. For the horizontal experimental holes, the flow of exhaust air through the holes was decreased by improving the airtightness, and a decay duct of capacity 2.4 m_3 was installed in the middle of the exhaust line. In consequence, the release rate of _4_1Ar was reduced by 6-8%. For the pneumatic tubes, a mechanical shutter was installed in the tube. The shutter stops the exhaust air flow, except when the pneumatic tube is used. Prior to the use, the activated air in the tube is led to a decay tank. As a result, the _4_1Ar release rate was reduced by 10-20%. By the above means, the yearly exposure at the site boundary was reduced to 0.36 mR from 2.6 mR. In Hot Laboratory for metallurgical examination of spent fuel, the exhaust filtration system consists of filters in the cave, i.e. frame trap, prefilter, HEPA ...

1983-05-01

129

Development of an incinerator using ceramic filters for low level radioactive solid waste treatment  

International Nuclear Information System (INIS)

This facility has treatment capacity of 12 kg/hr, and is equipped with a furnace, two ceramic filter chambers, each of which hangs inside the 36 ceramic filter elements having mean pore size of 44 #mu#m. Three series of experiments were performed during a period from October 1972 to August 1973. The first was measurement of the change of pressure drop of the primary and the secondary filters after an operation of 52 days (352 hours). The pressure drop of the primary filter did not change during the operation, but the secondary brought a fairly large increment, from 79 to 140 mmAq. The second was measurement of the after-burning effect of the primary filter for the soot and tar in the off-gas. Through the after-burning most of the soot was removed from the off-gas, though the tar was not perfectly taken off. At the secondary filter, some of the tar was burnt, but ...

130

On the plasma rotation in a straight magnetized filter of a pulsed vacuum arc  

International Nuclear Information System (INIS)

In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify ...

2007-01-21

131

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the ...

2009-01-01

132

Industrial experience with an intelligent AC/DC standard  

Energy Technology Data Exchange (ETDEWEB)

AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.

1989-04-01

133

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

134

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

135

Determination of efficiency curves of germanium detectors using natural radioactive materials  

International Nuclear Information System (INIS)

Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).

136

Thermal infrared spectra of surface rocks. Comparison of in the laboratory, in situ, and remote sensing data; Chihyo ganseki no netsusekigaiiki bunko tokusei. Chijo sokutei data to remote sensing data no hikaku  

Energy Technology Data Exchange (ETDEWEB)

An ASTER (advanced spaceborne thermal emission and reflection radiometer) is one of the image sensors. It is to be installed in an earth survey polar orbit platform satellite, EOS-AM1, which is to be launched in 1998, and it is going to start its operation. Data observed by the thermal infrared remote sensing of ASTER include the spectral emissivity, and the spectral emission reflectivity which is expressed by the function of temperature. It is required to overcome technical problems how to extract the spectral emissivity from the observed data. The spectral emissivity extracted from the remote sensing data by the MMD method, measured for samples collected in Cuprite area, Nevada, and/or measured at sampled points were compared to each other and discussed. The hemisphere spectral reflectivity, which is indirect spectral emissivity, agreed well with the direct spectral emissivity. Data suggesting the establishment of Kirchhoff`s law were obtained even for the ...

1996-10-01

137

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.

1988-01-01

138

Testing of the SpinTek Rotary Microfilter Using Actual Waste  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy selected caustic-side solvent extraction (CSSX) as the preferred cesium-removal technology for SRS high-level waste. In the pretreatment step of the CSSX flowsheet, the incoming salt solution, which contains entrained sludge, is contacted with MST to adsorb strontium and selected actinides. An alternative approach replaces MST with the addition of sodium permanganate, strontium nitrate, and hydrogen peroxide. The pretreatment operation then filters the resulting slurry to remove the sludge and MST or manganese oxide and strontium carbonate solids. The filtrate receives further treatment in the solvent extraction system. SRTC personnel coordinated tests using a SpinTek rotary microfilter at the vendor location in FY01. These tests demonstrated a significant improvement - 2.5 to 6 times increase - in performance relative to the conventional cross-flow filter units. Rotary microfilter testing used a ...

2004-02-13

139

The protective role of ceramic filters against natural radioactivity of water  

International Nuclear Information System (INIS)

The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 #+-# 18%; the 'gross' beta by 1.53 #+-# 1.6%. (author).

140

Simulation of non-linear and switching elements for transient analysis based on wave digital filters  

Science.gov (United States)

A previous paper introduced the use of wave digital filters as a basic building block for power system simulation, particularly suitable for real-time applications. This paper stresses the simulation of non-linear and switching elements, emphasizing the advantages of the wave filters implementation. The digital structure is maintained even when non-linear components change their characteristics or power electronic devices switch their states. As a very important by-product, the suppression of numerical oscillations related to the trapezoidal rule is achieved in a rather simple way, with no effects on simulation results.

1996-10-01

141

Predicting the efficiency of activated charcoal for filtering radon  

Energy Technology Data Exchange (ETDEWEB)

In order to accurately assess the effectiveness of activated charcoal for the removal of radon from flowing air, a literature survey was performed to identify the models and relevant data that were available. It was found that by modifying the mathematical model of equilibrium stage theory used by Strong and Levins, the output rate of an activated charcoal filter exposed to a step function input in the radon rate at time zero with a given carrier gas flow velocity could be predicted. This paper outlines the modifications made to Strong and Levins's model and presents predictions for the filter output from the modified model.

1993-01-01

142

New method of determining the overall particle decontamination factor for multiple offgas cleaning components in reprocessing plants  

International Nuclear Information System (INIS)

When combining aerosol retention components in the dissolver offgas stream of a reprocessing plant, the behavior both of the individual aerosol filter stages and the overall removal efficiency of all filters connected in series vis-a-vis an aerosol spectrum to be expected must be determined for the benefit of the licensing authority. A fast method of determining removal efficiencies is described, which can also be applied in hot operation. This method was used to demonstrate, with high certainty, decontamination factors of a whole filter train in the range of 10"7.

1983-02-01

143

Walther process  

Energy Technology Data Exchange (ETDEWEB)

The article focusses on operational experience gained with the following items: scrubbing system with oxidation, regenerative gas preheater, blower/fan, aerosol filter, and product processing. (orig./PW).

1985-09-01

144

Technique for compressing light intensity ranges utilizing a specifically designed liquid crystal notch filter  

Energy Technology Data Exchange (ETDEWEB)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.

1988-01-01

145

TUNABLE FIBER FABRY-PEROT FILTER FOR OPTICAL CARRIER-SUPPRESSION AND SINGLE-SIDEBAND MODULATION IN RADIO OVER FIBER LINKS  

British Library Electronic Table of Contents (United Kingdom)

A novel method of simultaneous realization of optical carrier-suppression and single-sideband modulation using fiber Fabry-Perot tunable filter is presented. In order to enhance transmission performance of radio over fiber links, we use a fiber Fabry-Perot tunable filter to filter out one sideband as well as suppress the optical carrier power. The results demonstrate 20.5dB and 14.2dB improvement in the signal noise ratios when 18GHz and 10GHz microwave signals carrying 5Mbit/s quadrature-phase-shift-keyed (QPSK) format data is transmitted over 35 km single mode fiber, respectively.

2006-01-01

146

TOPIC O4 Navigation - NASA's SBIR & STTR Programs  

Science.gov (United States)

Applications of cutting-edge estimation techniques, such as, but not limited to, sigma-point and particle filters, to spaceflight navigation problems. ...

147

Simulation study of feedback systems based on a two-tap FIR filter. Under beam-beam collisions  

Energy Technology Data Exchange (ETDEWEB)

The performance of bunch-feedback systems based on two-tap FIR filters is discussed, particularly for transverse cases. Since they are the simplest type of FIR digital filters, the two-tap FIR filters should be suited to systems that require a very fast processing speed. However, in these feedback systems, a bunch must turn along a ring several times from the position-measurement to feedback kicking. Within these turns, irregular phase-jumps in the betatron motion can occur, due to several causes, such as the wake forces and beam-beam force. The discussion given in this paper is focussed on the effect of beam-beam collisions on these feedback systems. Based on linear theory and simulation studies, it has been found that these feedback systems can work with good performance, even under the influence of a strong beam-beam force. (author)

1998-04-01

148

New anti-jamming technique for GPS and GALILEO receivers using adaptive FADP filter  

British Library Electronic Table of Contents (United Kingdom)

Anti-jamming techniques to improve Global Positioning System (GPS) receivers robustness have been mainly developed in military applications. None of civilian techniques can procure sufficient robustness against occasional or intentional jammers for civil GPS or GALILEO navigation receivers. The amplitude domain processing (ADP) filtering is a technique based upon Capon works and Neyman-Pearson theory. Several experiments concerning the ADP filtering have been considered at the 3DETSNAV division of LACIME laboratory at Ecole de technologie superieure (ETS), which have proved that the technique is reliable in order to eradicate powerful interference present in the spread spectrum signal. However, the results show that the ADP filter has a real limitation when submitted to multiple interferen...

2006-01-01

149

MASTER - NASA Technical Reports Server  

Science.gov (United States)

Reactor Effluent Purification System. 7.4.3. Filter Reactor Outlet Gas (FROG). 7.5. Instrumentation and Controls for NSS Tests ...

150

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

151

Kepler: Transit Detection - Kepler - NASA  

Science.gov (United States)

Nov 12, 2010 ... The adaptive, nonparametric matched filter algorithm suggested by Kay ... For the point design of a 4 sigma single event SNR the combined NR ...

152

Efficient DSP Hardware Implementations for Navy RF Systems  

Science.gov (United States)

... of the loop filter based on ... algorithms, including delta-sigma approaches, routinely uses double-precision floating point number representations for ...

2010-09-30

153

Effect of application rates and media types on nitrogen and surfactant removal in trickling filters applied to the post-treatment of effluents from UASB reactors  

International Nuclear Information System (INIS)

Tricking filters are a very promising alternative for the post treatment of effluents from UASB reactors treating domestic sewage,especially in developing countries. Although a fair amount of information is already available regarding organic mater removal in this combined system, very little is known in relation to nitrogen and surfactant removal in trickling filters post-UASB reactors. Therefore, the purpose of this study was to evaluate and compare the effect evaluate and compare the effect of different application rates and packing media types on trickling filters applied to the post-treatment of effluents from UASB reactors, regarding the removal of ammonia nitrogen and surfactants. (Author)

154

CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...  

Science.gov (United States)

Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...

155

CBSD Version 2 Component Models of the IR Celestial ...  

Science.gov (United States)

... 1-sigma ZOHF pixel-to-plxel statistical fluctuations ... Spatial frequency filtering shows distinct bands, but miss ... LOS emissivity at the point of closest ...

1990-12-07

156

A Neuro-Fuzzy Multi Swarm FastSLAM Framework  

CERN Document Server

FastSLAM is a framework for simultaneous localization using a Rao-Blackwellized particle filter. In FastSLAM, particle filter is used for the mobile robot pose (position and orientation) estimation, and an Extended Kalman Filter (EKF) is used for the feature location's estimation. However, FastSLAM degenerates over time. This degeneracy is due to the fact that a particle set estimating the pose of the robot loses its diversity. One of the main reasons for loosing particle diversity in FastSLAM is sample impoverishment. It occurs when likelihood lies in the tail of the proposal distribution. In this case, most of particle weights are insignificant. Another problem of FastSLAM relates to the design of an extended Kalman filter for landmark position's estimation. The performance of the EKF and the quality of the estimation depends heavily on correct a priori knowledge of the process and measurement noise ...

2010-01-01

157
158

3-D depth migration via McClellan transformations  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient algorithm for 3-D depth migration. 21 ...

1990-01-01

159

Dating divergences in the Fungal Tree of Life: review and new analyses.  

Science.gov (United States)

The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...

160

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...

2010-08-15

161

Particle Flow at CMS and the ILC  

CERN Document Server

This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...

2010-01-01

162

Low-range flowmeters for use with vacuum and leak standards  

Energy Technology Data Exchange (ETDEWEB)

Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.

1987-05-01

163

Experimental compliance calibration for the mixed-mode bending (MMB) specimen  

Energy Technology Data Exchange (ETDEWEB)

A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.

1997-12-31

164

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-15

165

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-01

166

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

167

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

168

Analysis of installation damage tests for LRFD calibration of reinforced soil structures  

British Library Electronic Table of Contents (United Kingdom)

North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...

2011-01-01

169

A refined lack-of-fit statistic to calibrate pesticide fate models for responsive systems  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...

2009-01-01

170

Model system using coliphage phi X174 for testing virus removal by air filters.  

UK PubMed Central (United Kingdom)

Short-term (15-min-duration) and long-term (5- to 6-day-duration) test procedures have been developed for determining the efficiency of the removal of bacteriophage phi X174 by air-sterilizing filters....Full Text Available

1992-03-01

171

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

172

Glovebox  

Energy Technology Data Exchange (ETDEWEB)

On handling nitric solutions in the glove box nitrous gases are formed that are sucked off via a heated activated charcoal filter and a catalyst cartridge containing e.g. the FG 590 H catalist (Degussa). By the activated charcoal the nitrous gases are reduced to N/sub 2/ and CO gas; the catalyst will oxidize CO to CO/sub 2/. The CO/sub 2/ obtained is discharged through an exhaust air filter in the glove box.

1980-02-21

173

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

174

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

175

Covariance matrices for track fitting with the Kalman filter  

Science.gov (United States)

We present a simple and intuitive derivation of the track parameter covariance matrix due to multiple Coulomb scattering for use in track fitting with the Kalman filter. We derive all the covariance matrix elements for two experimentally relevant track parameterizations (i.e. x and y slopes and intercepts, and direction cosines and intercepts) in the presence of thin scatterers and absence of magnetic fields. We further comment on how to account for thick and/or continuous scattering centers.

1993-06-01

176

Optimization algorithm for linearity enhancement in the design of continuous-time sigma-delta modulators  

Science.gov (United States)

This paper proposes an optimization algorithm to reduce the distortion produced in the loop-filter of Continuous-Time Sigma-Delta Modulators. The aim of the algorithm is to find the loop-filter implementation that minimizes distortion at the output of the modulator, by modifying the output swing of every integrator. The algorithm is implemented in Matlab as an evolutive searching. During each step of the searching, the algorithm evaluates the harmonical distortion of a tone when it is applied to the modulator with a certain loop-filter implementation. The output of the algorithm is an optimum linear state-space representation of the loop-filter. This particular state-space representation leads to minimum distortion at the output of the modulator when the loop-filter is implemented with some specific circuitry previously defined. As long as the search is of evolutive type, the ...

2005-06-01

177

Manganese removal using an aerated granular filter  

Energy Technology Data Exchange (ETDEWEB)

Experiments on manganese removal using an aerated granular filter with mean particle size of 3.68 mm and 5.21 mm anthracite were conducted at a filtration rate of 100 m d{sup -1}. Air, with a rate of 0 to 366 m d{sup -1}, was supplied through nozzles positioned 100 mm above the filter column bottom. From the experiments that were conducted, it was found that manganese removal is completed at a pH of 9.6 or above. In addition, the oxidation and removal rate of dissolved manganese were expressed as a first-order reaction. The smaller the filter media particles were, the higher the manganese removal efficiency was. The aeration rate of dissolved oxygen in raw water is sufficient for the manganese removal process. The manganese removal rate increased with time due to the catalytic effect of manganese dioxide (MnO{sub 2}) attached to the media. The x-ray diffraction analysis showed that the solids attached to the ...

2007-09-15

178

Evaluation of the effectiveness of an antimicrobial air filter to avoid porcine reproductive and respiratory syndrome virus (PRRSV) aerosol transmission, after 16 months of exposure to a commercial swine environmental conditions  

Energy Technology Data Exchange (ETDEWEB)

The effectiveness of Noveko's antimicrobial filter was evaluated after 16 months of exposure to commercial swine production. The experiment involved the use of a scaled model of a commercial swine facility consisting of 2 small chambers connected by a duct containing the filters. A 5 kg naive pig was placed in the reception chamber for a period of 6 hours after aerosolization with porcine reproductive and respiratory syndrome virus (PRRSV). Blood samples from pigs were collected before and after aerosolization to test for the presence of PRRSV RNA. Only blood samples were tested for PRRSV antibodies by IDEXX 2XR ELISA. None of the 9 pigs tested were found to be infected. The study showed that the technology used to integrate the antimicrobial agent into the filter fibers allows the filter combination to withstand extreme weather and endure commercial swine production for at least 16 months, and ...

2010-07-01

179

Collection efficiency and decontamination factor of HEPA filter  

International Nuclear Information System (INIS)

It is very important in a nuclear air cleaning system that HEPA (High Efficiency Particulate Air) filter is for reduction of releasing amounts of airborne radioactive particles. HEPA filter, by definition, has a minimum collection efficiency of 99.97 % for 0.3 #mu#m particles. However, DF (Decontamination Factor), which is necessary for safety management, can not be directly derived from the efficiency. And the current standard defined for 0.3 #mu#m particles has no scientific justification, because it has been found that the most penetrating particle size through HEPA filter is not always 0.3 #mu#m. In the present paper, a numerical experiment was made in order to estimate a relationship between DF and the efficiency. And new standard, in which the minimum DF is able to be easily obtained, was proposed. In the multistage filtration system, it was found that lower values of DF was possible to be experimentally indicated in ...

180

UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)

1991-07-30

181

Spectral Cross-calibration of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT Data using Gamma-Ray Bursts  

CERN Document Server

We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...

2010-01-01

182

Measurements of Spectral Characteristics of Swimmer Targets ...  

Science.gov (United States)

... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...

1974-05-01

183

Los Alamos second-generation system for passive and active neutron assays of drum-size containers  

International Nuclear Information System (INIS)

We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...

1972-09-17

184

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

185

Exploding Bridgewire Electrical System Test Unit.  

Science.gov (United States)

The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...

1964-01-01

186

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

187

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

188

COSPIN-ANISOTROPY TELESCOPE for ULY - PDS - NASA  

Science.gov (United States)

To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...

189

Binary pseudo-random gratings and arrays for calibration of the modulation transfer function of surface profilometers: recent developments  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...

2009-07-07

190

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

191

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

192

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

193

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

194

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

195

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...

1997-12-31

196

Software framework and jet energy scale calibration in the ATLAS experiment; Environnement logiciel et etalonnage de l'echelle en energie des jets dans l'experience ATLAS  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...

2006-07-01

197

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...

2006-04-01

198

Depth migration in transversely isotropic media with explicit operators  

Energy Technology Data Exchange (ETDEWEB)

The author presents and analyzes three approaches to calculating explicit two-dimensional (2D) depth-extrapolation filters for all propagation modes (P, SV, and SH) in transversely isotropic media with vertical and tilted axis of symmetry. These extrapolation filters are used to do 2D poststack depth migration, and also, just as for isotropic media, these 2D filters are used in the McClellan transformation to do poststack 3D depth migration. Furthermore, the same explicit filters can also be used to do depth-extrapolation of prestack data. The explicit filters are derived by generalizations of three different approaches: the modified Taylor series, least-squares, and minimax methods initially developed for isotropic media. The examples here show that the least-squares and minimax methods produce filters with accurate extrapolation (measured in the ability to ...

1994-12-01

199

Widely Linear Kalman Filtering  

CERN Document Server

For a zero mean, proper, complex random vector x, the Hermitian covariance ExxH is a complete second-order characterization. However, if the vector x is improper, it is correlated with its complex conjugate, meaning ExxT = 0. This improper or complementary covariance must be accounted for in a complete second-order characterization. The improper covariance has been exploited for widely linear (WL) Wiener filters and WL minimum mean squared error (MMSE) estimators, and the improvement in performance of the WLMMSE estimator over the LMMSE estimator has been quantified. In this paper we consider the design of the widely linear Kalman filter (WLKF). We analyze the WLKF, extended WLKF, and unscented WLKF. The key idea of this paper is to modify the error covariance matrices and the construction of effective sigma points in the WLKF in a systematic way that exploits the Hermitian and complementary covariance of improper states and noises.

2011-01-01

200

Tunneling magnetoresistance from a symmetry filtering effect  

International Nuclear Information System (INIS)

This paper provides a brief overview of the young, but rapidly growing field of spintronics. Its primary objective is to explain how as electrons tunnel through simple insulators such as MgO, wavefunctions of certain symmetries are preferentially transmitted. This symmetry filtering property can be converted into a spin-filtering property if the insulator is joined epitaxially to a ferromagnetic electrode with the same two-dimensional symmetry parallel to the interface. A second requirement of the ferromagnetic electrodes is that a wavefunction with the preferred symmetry exists in one of the two spin channels but not in the other. These requirements are satisfied for electrons traveling perpendicular to the interface for Fe-MgO-Fe tunnel barriers. This leads to a large change in the resistance when the magnetic moment of one of the electrodes is rotated relative to those of the other electrode. This large tunneling magnetoresistance effect is ...

2008-04-01

201

Sound climate installations. Gezonde klimaatinstallaties  

Energy Technology Data Exchange (ETDEWEB)

An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella pneumophila), ...

1989-10-01

202

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of /sup 54/Mn, /sup 59/Fe, /sup 60/Co, /sup 65/Zn and /sup 137/Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10/sup 5/. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin.

1987-02-01

203

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

International Nuclear Information System (INIS)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of "5"4Mn, "5"9Fe, "6"0Co, "6"5Zn and "1"3"7Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10"5. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin. (author).

204

Improvement of tracking performance using prediction-based algorithms for a maneuvering target  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a study involving prediction of a complicated maneuvering target, with the aim of improving the tracking performance of a fire control system (FCS). In this study, we predict the position of a complicated maneuvering target 5 s in advance using the information up to the current time. Because of the large error caused by the complicated maneuvers and the long prediction time interval, the mechanical system of the fire control system will take a heavy load. In order to cope with this problem, several approaches to decreasing the prediction error have been proposed including the prediction algorithms based on the multiple model(MM) filter, interacting multiple model (IMM) filter, and variable dimension with input estimation (VDIE) filter. Finally, comparative simulation re...

2011-01-01

205

Ecological risk assessment of water environment for Luanhe River Basin based on relative risk model  

British Library Electronic Table of Contents (United Kingdom)

The relative risk model (RRM) was applied in regional ecological risk assessments successfully. In this study, the RRM was developed through increasing the data of risk source and introducing the source?stressor?habitat exposure filter (SSH), the endpoint?habitat exposure filter (EH) and the stressor?endpoint effect filter (SE) to reflect the meaning of exposure and effect more explicit. Water environment which include water quality, water quantity and aquatic ecosystems was selected as the ecological risk assessment endpoints. The Luanhe River Basin located in the North China was selected as model case. The results showed that there were three low risk regions, one medium risk region and two high risk regions in the Luanhe River Basin. The results also indicated habitat destruction was th...

2010-01-01

206

Design: voice activated door opener.  

Science.gov (United States)

A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601

1993-01-01

207

DNase-resistant transfer of chromosomal cat and tet insertions by filter mating in pneumococcus  

Energy Technology Data Exchange (ETDEWEB)

Genes for chloramphenicol resistance, Cm(r) and tetracycline resistance, Tc(r), which are present as heterologous insertions in the chromosomes of some clinical isolates of Streptococcus pneumoniae (pneumococcus) and derivative strains, were transferred at a low frequency to other pneumococci by a DNase-resistant filter mating process that resembles conjugation. Cotransfer of Cm(r) and Tc(r) was the most common event. Neither the donor strains nor the transconjugants contained detectable plasmids. Transconjugants acted as donors for transformation and for filter mating and had properties similar to those of the parent strain. The presence of the conjugative plasmid pIP501 in the donor did not appear to influence the transfer properties of the Cm(r) or Tc(r) determinants.

1980-01-01

208

Characterization of Filter Elements for Service in a Coal Gasification Environment  

Energy Technology Data Exchange (ETDEWEB)

The Power Systems Development Facility (PSDF) is a joint Department of Energy/Industry sponsored engineering-scale facility for testing advanced coal-based power generation technologies. High temperature, high pressure gas cleaning is critical to many of these advanced technologies. Barrier filter elements that can operate continuously for nearly 9000 hours are required for a successful gas cleaning system for use in commercial power generation. Since late 1999, the Kellogg Brown & Root Transport reactor at the PSDF has been operated in gasification mode. This paper describes the test results for filter elements operating in the Siemens-Westinghouse particle collection device (PCD) with the Transport reactor in gasification mode. Operating conditions in the PCD have varied during gasification operation as described elsewhere in these proceedings (Martin et al, 2002).

2002-09-19

209

Application of feedback connection artificial neural network to seismic data filtering  

CERN Document Server

The Elman artificial neural network (ANN) (feedback connection) was used for seismic data filtering. The recurrent connection that characterizes this network offers the advantage of storing values from the previous time step to be used in the current time step. The proposed structure has the advantage of training simplicity by a back-propagation algorithm (steepest descent). Several trials were addressed on synthetic (with 10% and 50% of random and Gaussian noise) and real seismic data using respectively 10 to 30 neurons and a minimum of 60 neurons in the hidden layer. Both an iteration number up to 4000 and arrest criteria were used to obtain satisfactory performances. Application of such networks on real data shows that the filtered seismic section was efficient. Adequate cross-validation test is done to ensure the performance of network on new data sets.

2008-01-01

210

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

211

The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors  

Energy Technology Data Exchange (ETDEWEB)

Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...

1996-01-01

212

Temporal measures and controls in ultrafast laser domain; Mesures et controles temporels dans le domaine des lasers ultrabrefs  

Energy Technology Data Exchange (ETDEWEB)

This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements require a linear ...

2004-12-15

213

Synchrony between orientation-selective neurons is modulated during adaptation-induced plasticity in cat visual cortex  

UK PubMed Central (United Kingdom)

BackgroundVisual neurons respond essentially to luminance variations occurring within their receptive fields. In primary visual cortex, each neuron is a filter for stimulus features...Full Text Available

214

Suitability of filter ash surfaces as locations for plants  

Energy Technology Data Exchange (ETDEWEB)

The possibility of a positive agricultural use of flue gas filter ash from brown coal power plants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal power plants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 cm. Tests of plant ...

1980-01-01

215

Selection of Inhibitor-Resistant Viral Potassium Channels Identifies a Selectivity Filter Site that Affects Barium and Amantadine Block  

UK PubMed Central (United Kingdom)

BackgroundUnderstanding the interactions between ion channels and blockers remains an important goal that has implications for delineating the basic mechanisms of ion channel function...Full Text Available

216

Print - NASA  

Science.gov (United States)

Jul 17, 2008 ... The first version uses a red-green-blue filter; the second, an infrared-green- blue. Videos credit: Donald J. Lindler, Sigma Space Corporation/GSFC; ... The video will help us connect a varying point of planetary light ...

217

Premium performance heating oil - Part 2, Field trial results  

Energy Technology Data Exchange (ETDEWEB)

Limited field trial results of a heating oil additive package developed to minimize unscheduled maintenance indicate that it achieves its goal of keeping heating oil systems cleaner. The multifunctional additive package was developed to provide improved fuel oxidation stability, improved corrosion protection, and dispersency. This combination of performance benefits was chosen because we believed it would retard the formation of sludge, as well as allow sludge already present to be carried through the system without fouling the fuel system components (dispersency should keep sludge particles small so they pass through the filtering system). Since many unscheduled maintenance calls are linked to fouling of the fuel filtering system, the overall goal of this technology is to reduce these maintenance calls. Photographic evidence shows that the additive package not only reduces the amount of sludge formed, but even removes existing sludge from ...

1996-07-01

218

Name of Presentation!  

Wastenet

Up-flow anaerobic attached-growth bioreactors filled with pre-treated coir fibres ...coir-fibre arranged in bottle-brush configuration bounded by a novel plastic binding technique ...-three anaerobic filter reactors in series -coir fibre as the bacteria growth media a sedimentation

219

Membrane filtration of food suspensions.  

UK PubMed Central (United Kingdom)

Factors affecting the membrane filtration of food suspensions were studied for 58 foods and 13 membrane filters. Lot number within a brand, pore size (0.45 or 0.8 micrometer), and time elapsed before...Full Text Available

1979-01-01

220

MSI Observation Overview Document Author - Ann Harch, Cornell ...  

Science.gov (United States)

Seq 1 was 8 images spaced 2sec apart, 999 ms man exp, filter 0. ... This region is the 2 sigma ellipsoid. This means, there was 90% chance that ... At this point the ellipse was fat and collapsed as we were still looking more or less ...

221

Iterative estimation of the background in noisy spectroscopic data  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we present an iterative filtering method to estimate the background of noisy spectroscopic data. The proposed method avoids the calculation of the average full width at half maximum (FWHM) of the whole spectrum and the peak regions, and it can estimate the background efficiently, especially for spectroscopic data with the Compton continuum.

2009-04-21

222

GRB 090510 - GCN - NASA  

Science.gov (United States)

May 10, 2009 ... The estimated magnitude is 18.95 with a 1-sigma error of about 0.17. ... The points of contact for this burst is Masanori Ohno .... 80 seconds after the BAT trigger with a settling exposure in the UVOT v filter. ...

223

GCN/MOA Gravitational Lensing Event Notices - GCN - NASA  

Science.gov (United States)

Jul 16, 2011 ... The standard filtering applies to all the existing distribution methods/media. ... needed to allow your data point(s) to be added to the MOA lightcurve. .... name="t1" value="0.00" unit="sigma" ucd="stat.snr" />

224

GCN/Fermi GRB and Transient Notices - GCN - NASA  

Science.gov (United States)

The GBM location uncertainties range from 5-15deg (radius, 1 sigma, stat+sys). ... The site's dis/enabling on Notice types and their other filter criteria .... Fermi Pointing Direction Notice gives the current pointing direction of the ...

225

Federated sigma point filter for multi-sensor attitude and rate estimation of spacecraft  

Science.gov (United States)

High precision, fast computation speed, as well as a good capability of fault tolerant and reconstruction are required more and more for spacecraft attitude determination system. To realize the above requirement, an approach was presented to the synthesis of federated filters using sigma point technique. In this algorithm, the sigma point technique brought the algorithm a high precision, while the federated structure significantly enhanced the filters' capability of multi-rate information fusion, fault tolerance, and system modularity. Within consideration of computation consumption, a simple information-sharing formulation was derived to adapt to the special property of sigma point distribution, and a dynamical information sharing strategy for multi-rate fusion was developed. A numerical simulation example was employed to give the algorithm a test, where the simulated system contained a suit of gyroscopes; a three-axis magnetometer and a sun ...

2008-11-01

226

FDA Survey of Imported Fresh Produce - Import Produce Assignment ...  

Science.gov (United States)

... dilutions greater than 10 -5 for an end-point. ... Polyvinyl polypyrrolidone (PVPP) (Sigma, P-6755); NET buffer ... The adsorbent celite should prevent filter clogging. ...

227

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

228

Dried blood spots as a source of anti-malarial antibodies for epidemiological studies  

UK PubMed Central (United Kingdom)

BackgroundBlood spots collected onto filter paper are an established and convenient source of antibodies for serological diagnosis and epidemiological surveys. Although recommendations...Full Text Available

229

Dosing Recommendations for Continuous Venovenous Hemodiafiltration with AN69 Filter Membranes and Prismaflex Dialyzers  

UK PubMed Central (United Kingdom)

Background:Continuous renal replacement therapy is used to manage fluid and solute imbalances in critically ill patients but may affect the clearance of concurrently administered...Full Text Available

2009-11-01

230

Chromatography Equipment on Environmental Expert  

Wastenet

...for free Subscribe your products Categories All Categories Monitoring & Testing ChromatographyDelete Category Filter anion exchange chromatography biogas chromatographs chromatographic media chromatographic separations chromatographs chromatography ...

231

Ceramics Thermosynthesis in Combustion Wave  

International Science & Technology Center (ISTC)

Development of New Resource-Saving Technologies for Ceramic Material Production: High resistant Pigments, Heat Shielding, Plasters, Filters, etc.; by the Method of Controllable Thermosynthesis in Combustion Wave Using Industrial Metal-Containing Wastes

232

CHANDFS2MS - Chandra Deep Field South 2 ... - HEASARC - NASA  

Science.gov (United States)

This table contains point-source catalogs for the ~2 Ms exposure of the Chandra Deep ... Source positions are determined using centroid and matched-filter techniques; .... The 1-sigma upper statistical error (Gehrels 1986, ApJ, 303, ...

233

CERES BDS Quality Summaries - Atmospheric Science Data Center - NASA  

Science.gov (United States)

Nov 18, 2010 ... Roughly speaking, the fidelity interval we quote is a "3 sigma" value. ... surface of the foremost quartz filter which is then chemically altered by ... ( CERES) scanner point accuracy using a coastline detection system", ...

234

Automatic scene-adaptive pattern removal  

Energy Technology Data Exchange (ETDEWEB)

A new method for removing periodic background patterns from pictures is presented. The basic spatial frequency composition of the pattern is determined from an estimate of the power spectrum of the picture. A digital restoration filter is then created from a modified version of the power spectrum. The method is extremely effective and can be automated.

1982-01-01

235

Air conditioner for radioactive material handling facility  

Energy Technology Data Exchange (ETDEWEB)

An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. ...

1991-04-26

236

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

237

AVISO and PODAAC User Handbook IGDR and GDR Jason Products - NASA  

Science.gov (United States)

An ascending node occurs when the subsatellite point crosses the earth's equator going from .... 11dB sigma-naught. This error budget includes the altimeter noise, ...... it is also recommended to filter the data as follows to ...

238

AAS 94-164 Demonstration of a Precision Data Reduction Technique ...  

Science.gov (United States)

and a flyby of the asteroid Ida, the enhanced filter is shown to substantially improve the ... twoway range, and ADOR data points acquired at S-band frequencies. .... The result of this fit and its l-sigma uncertainty ellipse is ...

239

A widely tunable continuous-time LPF for a direct conversion DBS tuner  

Energy Technology Data Exchange (ETDEWEB)

A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in 0.35 mum SiGe BiCMOS technology. The filter's -3 dB cutoff frequency f{sub 0} can be tuned from 4 to 40 MHz. A novel on-chip automatic tuning scheme has been successfully realized to tune and lock the filter's cutoff frequency. Measurement results show that the filter has -0.5 dB passband gain, +-5% bandwidth accuracy, 30 nV/Hz{sup 1/2} input referred noise, -3 dBVrms passband IIP3, and 27 dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 13 mA (with f{sub 0} = 20 MHz) from 5 V supply, and occupy 0.5 mm{sup 2}.

2009-02-15

240

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

241

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

242

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...

2010-10-01

243

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...

2002-07-01

244

Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code  

Energy Technology Data Exchange (ETDEWEB)

In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...

1998-12-01

245

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

Energy Technology Data Exchange (ETDEWEB)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...

2007-12-15

246

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

International Nuclear Information System (INIS)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...

2007-12-01

247

Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy  

International Nuclear Information System (INIS)

Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly ...

1990-08-26

248

Ground- and space-based temperature and humidity retrievals: Statistical evaluation  

Energy Technology Data Exchange (ETDEWEB)

A near-real-time integrated temperature and water vapor sounding system has been designed and in operation since June 1993. It combines hourly data from the ground-based radio acoustic sounding system (RASS), a two-channel microwave radiometer, standard surface meteorological instruments, a lidar ceilometer, and the Aerodynamic Research Incorporated Communication, Addressing and Reporting System aboard commercial airlines with space-based data from the TIROS-N Operational Vertical Sounder (TOVS). The physical retrieval algorithm provided by the International TOVS Processing Package is used for combining the ground- and space-based temperature and humidity profiles. The first-guess profiles of temperature and humidity required by the physical retrieval algorithm are obtained by using a statistical inversion technique and the ground-based remote sensors measurements. Statistical error estimates are presented for the hourly, near-real-time, ground-, and space-based ...

1996-03-01

249

Efficient preparation of 99mTc(III) '4+1' mixed-ligand complexes for peptide labeling with high specific activity  

International Nuclear Information System (INIS)

An improved labeling procedure for peptides attached to organometallic 99mTc(III) '4+1' mixed-ligand complexes in which the radiometal is coordinated by a tripodal tetradentate chelator 2,2',2''-nitrilotriethanethiol (NS3) and a monodentate isocyanide ligand is presented. The labeling procedure was evaluated by the synthesis of [99mTc(NS3)(L2-RGD)]. The containing radiopharmaceutically interesting RGD-peptide cyclo[Arg-Gly-Asp-D-Tyr-Lys] was modified with 4-isocyanobutanoic acid (L2) as linker conjugated to N6-Lys to get the monodentate ligand L2-RGD. The structural identity of the 99mTc-conjugate was confirmed by comparison to a Re reference compound. The Tc- and Re-conjugates had matching retention times under identical HPLC conditions. The 99mTc-labeling was performed in a novel one-step procedure using the eluate of a 99Mo/99mTc generator, NS3, the isocyanide modified peptide, SnCl2, Na2EDTA, mannitol and ascorbic acid in the reaction mixture. Using optimized ...

2010-09-01

250

Development of a new radiolabel (lead-203) and new chelating agents for labeling monoclonal anntibodies for imaging  

International Nuclear Information System (INIS)

High liver uptake and slow body clearance presently limit the usefulness of "1"1"1In labeled antibodies for tumor imaging. We have investigated "2"0"3Pb as an alternate and better antibody label. The DTPA and cyclohexyl EDTA (CDTA) conjugates of an anticolon carcinoma antibody, 17-1A were labeled (bicyclic anhydride method) with "2"0"3Pb and "1"1"1In with 60 and 90% labeling yields, respectively. The biodistribution of "2"0"3Pb-17-1A conjugates was compared with the corresponding "1"1"1In-labeled preparations and with "2"0"3Pb-DTPA, "2"0"3Pb-nitrate and nonrelevant antibody controls in normal and human tumor (SW948) xenografted nude mice at 24, and 96 hr. Lead-203-labeled CDTA and DTPA antibody conjugates gave similar in vivo distributions. Even though the lead bound to these chelate-antibody conjugates was more labile in serum and in vivo, compared to indium, it cleared much faster from the liver and the whole body. A new series of chelating agents based on the incorporation of a ...

1988-05-22

251

Neural solution to the target intercept problems in a gun fire control system  

British Library Electronic Table of Contents (United Kingdom)

Time delay neural networks trained with the backpropagation algorithm are derived for the gun fire control system to correct the miss distance between a target and the projectiles from the gun. Its performance is compared to optimum linear filter based on minimum mean square error [R.E. Kalman, A new approach to linear filtering and prediction problems, J. Basic Eng. 82D (1960) 35-44.]. The structure of the proposed neural controller is described and performance results are shown.

2007-01-01

252

Entrained Solids, Strontium-Transuranic Precipitation, and Crossflow Filtration of AN102 Small C  

Energy Technology Data Exchange (ETDEWEB)

This work is the first active crossflow filter testing of the new strontium-permanganate process for Envelope C at the Savannah River Technology Center. Extreme filtration difficulties with the ferric hydroxide precipitation led to investigations of other chemistries with simulants. The current process includes the isotopic dilution by precipitation from inactive strontium nitrate addition. A permanganate strike to replace ferric reagents was found to provide practical filterability and good lanthanide or transuranic decontamination. That work had been supported with simulant and active beaker testing.

2000-09-27

253

Cubature Kalman smoothers  

British Library Electronic Table of Contents (United Kingdom)

The cubature Kalman filter (CKF) is a relatively new addition to derivative-free approximate Bayesian filters built under the Gaussian assumption. This paper extends the CKF theory to address nonlinear smoothing problems; the resulting state estimator is named the fixed-interval cubature Kalman smoother (FI-CKS). Moreover, the FI-CKS is reformulated to propagate the square-root error covariances. Although algebraically equivalent to the FI-CKS, the square-root variant ensures reliable implementation when committed to embedded systems with fixed precision or when the inference problem itself is ill-conditioned. Finally, to validate the formulation, the square-root FI-CKS is applied to track a ballistic target on reentry.

2011-01-01

254

A navigation filter for fusing DTM/correspondence updates  

CERN Document Server

An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.

2011-01-01

255

Model for predicting the effects of laser exposures and eye protection on vision. Interim report, January 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser safety standards and eye protection (filters) are designed to limit ocular exposures to prevent retinal lesions, yet eyesafe laser exposures can disrupt vision by causing glare and flashblindness. Protective filters can have opposing effects on vision function. They reduce laser exposures but also reduce task luminance and contrast. Filters alone may interfere with vision and consequently reduce work safety and performance. It is therefore important to be able to predict the effects of both laser exposures and protective filters to assess trade-offs between protection and visual function. This paper briefly reviews the methods, concepts, and experimental database used in our laboratory to predict laser, filter, and laser-plus-filter effects on tasks involving visual detection. The modeling approach uses estimates of the spatial distribution of light in the ...

1990-01-01

256

Lubricant wear particle analysis by filter patch extraction  

Energy Technology Data Exchange (ETDEWEB)

Lubricating Oil Analysis (LOA) has become an important part of a comprehensive Reliability Centered Maintenance (RCM) program. However, knowing the condition of the lubricant alone does not provide a complete description of equipment reliability. Condition monitoring for equipment can be accomplished through Wear Particle Analysis (WPA). This usually involves separating suspended materials and wear products from the lubricant by magnetic (ferrographic) means. This paper will present a simple, low-cost, alternate method of particle acquisition called Filter Patch Extraction (FPE). This method removes solids, regardless of their composition, from the lubricant by vacuum filtration and deposits them onto a filter for microscopic examination similar to that of analytical ferrography. A large filter pore size retains suspended materials and permits rapid filtration of large volumes of lubricant thereby increasing the accuracy of ...

1996-07-01

257

Investigation of techniques to improve continuous air monitors under conditions of high dust loading in environmental setting. 1998 annual progress report  

Energy Technology Data Exchange (ETDEWEB)

'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and ...

1998-06-01

258

H{sup -} ion source using a localized virtual magnetic filter in the plasma electrode: type I LV magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

A new multicusp H{sup -} ion source using a Localized Virtual magnetic filter of type I [Ref.6] in the plasma electrode is investigated. A multipole (MP) arrangement with a spacing of 10 mm of the magnet bars holds an extraction hole, optimizing the efficient production of high H{sup -} current, and at the same time only a small electron component was co-extracted with the H{sup -} ions. The local filter arrangement separates the beam electrons at a low energy. It is shown that the co-extracted total electron current is determined principally by the integrated magnetic field flux (Gcm) of the local filter with an extraction system at a constant extraction voltage. When the value of the Gcm is increased, the total electron component is reduced, while the H{sup -} electrical efficiency had a broad maximum around the optimized value of the Gcm. A thicker plasma electrode should be necessary for sufficient reduction of electron ...

1999-12-01

259

Experimental study of nanoparticles penetration through commercial filter media  

Energy Technology Data Exchange (ETDEWEB)

In this study, nanoparticle penetration was measured with a wide range of filter media using silver nanoparticles from 3 nm to 20 nm at three different face velocities in order to define nanoparticle filtration characteristics of commercial fibrous filter media. The silver particles were generated by heating a pure silver powder source via an electric furnace with a temperature of 870 deg. C, which was found to be the optimal temperature for generating an adequate amount of silver nanoparticles for the size range specified above. After size classification using a nano-DMA, the particle counts were measured by an Ultrafine Condensation Particle Counter (UCPC) both upstream and downstream of the test filter to determine the nanoparticle penetration for each specific particle size. Particle sampling time continued long enough to detect more than 10{sup 5} counts at the upstream and 10 counts at the downstream sampling point so ...

2007-01-15

260

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the charcoal and heat is generated. The part of ...

2006-11-13

261

[Comparison of wound morphology following gunshots by machine guns and sub-machine guns].  

Science.gov (United States)

Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...

262

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...

2009-01-01

263

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

264

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...

1997-06-01

265

Heat pump modeling in TRNSYS  

Energy Technology Data Exchange (ETDEWEB)

Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...

1997-11-01

266

Development of highly reliable screening by using x-ray fluorescence spectrometry. Applications to determine lead in tin plated and tin-bismuth plated samples  

International Nuclear Information System (INIS)

A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)

2009-03-01

267

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-15

268

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-01

269

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

270

The KCAL VERA 22 GHz calibrator survey  

CERN Document Server

We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.

2011-01-01

271

On the problem of magnitude calibration of palaeoearthquakes  

British Library Electronic Table of Contents (United Kingdom)

Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...

2011-01-01

272

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

273

Enamel-Calibrated Lamellar Bone Reveals Long Period Growth Rate Variability in Humans  

British Library Electronic Table of Contents (United Kingdom)

Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...

2011-01-01

274

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].

2005-06-11

275

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

276

Comparison of constitutive models for plastic-bonded explosives  

British Library Electronic Table of Contents (United Kingdom)

A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...

2008-01-01

277

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...

2007-07-25

278

An application of UV-derivative spectrophotometry and bivariate calibration algorithm for study of photostability of levomepromazine hydrochloride  

British Library Electronic Table of Contents (United Kingdom)

Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.

2008-01-01

279

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

280

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

281

Spectral D line of Na-like multicharged ions and phenomenological inclusion of the Lamb shift in the many-electron systems  

International Nuclear Information System (INIS)

Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.

282

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

283

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...

1995-05-01

284

Regulatory experience on safety system instrument uncertainty of Wolsong units  

International Nuclear Information System (INIS)

This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...

2001-05-01

285

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

286

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

287

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

288

Ground water modelling in artificial recharge projects  

International Nuclear Information System (INIS)

Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.

1991-05-09

289

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

290

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

291

Colorimetric porous indicator of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.

1986-03-01

292

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

293

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

294

Applications of Auger spectroscopy and ESCA to the study of thin films formed on metals  

International Nuclear Information System (INIS)

Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.

1979-05-23

295

An ultrasonic goniometer for surface stress measurement  

Science.gov (United States)

An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.

1978-09-01

296

An instrument for measuring spatial and time characteristics of sea agitation in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.

1981-01-01

297

WIS decontamination factor demonstration test with radioactive nuclides  

Energy Technology Data Exchange (ETDEWEB)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10/sup 5/ for every nuclide, and from the results of above DF, over 10/sup 8/ is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of ...

1987-04-01

298

WIS decontamination factor demonstration test with radioactive nuclides  

International Nuclear Information System (INIS)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10"5 for every nuclide, and from the results of above DF, over 10"8 is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of only single ...

299

Use of neutron activation analysis for the control of air pollution of Algiers; Utilisation de l'analyse par activation neutronique pour le controle de la pollution de l'air d'Alger  

Energy Technology Data Exchange (ETDEWEB)

The urban zone needs clean air to assure public health. To achieve this goal several filter samples were collected in different sites in Algiers city. Toxic elements such as: Na, Mg, Cl, Sc, Cr, Ti, V, Fe, Co, Cu, Zn, Se, Br, Ag, Sb, Ce, La, Hf, Ta and Hg have been measured in the filters using neutron activation analysis technique. Irradiation of filter samples and standards were carried out in Es-Salem reactor. The experimental procedure and the results are discussed. We noted during this work that the upper limit values for suspended dusts and the high concentrations for some toxic elements found are due to the weather conditions and intense road traffic around collecting sites. (authors)

2010-07-15

300

Treatment of waste rock piles at Wood Cadillac using a reducing trickling filter; Traitement des resurgences du parc a residus miniers Wood Cadillac au moyen d'un biofiltre reducteur  

Energy Technology Data Exchange (ETDEWEB)

The Ministere des Ressources naturelles du Quebec (Quebec Natural Resources Department) implemented a remedial program to treat the waste rock pile at Wood Cadillac, located near Cadillac, in Abitibi, Quebec. The solutions proposed by INRS-Georessources and ENVIROCONSEIL are aimed at eliminating erosion and stabilizing the geochemical processes. Part of the proposed solution also included the use of a reducing trickling filter for the treatment of acid leachates, which also contain arsenic when exiting the waste rock pile. The trickling filter is composed of forest tailings in which the bacteria reduce the sulphates and stimulate the precipitation of arsenic into arsenic sulphates. This is a new treatment that was developed following laboratory experiments which demonstrated the feasibility of the process and quantified the parameters. A demonstration unit was constructed by ENVIROCONSEIL and installed at the Wood Cadillac waste rock pile under ...

2000-07-01

301

The effect of the primary collimator and flattening filter on asymmetric fields for a Siemens PRIMUS linear accelerator  

CERN Document Server

Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under ...

2005-01-01

302

Reappraisal of solid selective emitters  

Energy Technology Data Exchange (ETDEWEB)

New rare earth oxide emitters show greater efficiency than previous emitters. As a result, based on a simple model the efficiency of these emitters was calculated. Results indicate that the emission band of the selective emitter must be at relatively low energy (less than or equal to .52 eV) to obtain maximum efficiency at moderate emitter temperatures (less than or equal to 1500 K). Thus low bandgap energy PV materials are required to obtain an efficient thermophotovoltaic (TPV) system. Of the 4 specific rare earths (Nd, Ho, Er, Yb) studied Ho has the largest efficiency at moderate temperatures (72 percent at 1500 K). A comparison was made between a selective emitter TPV system and a TPV system that uses a thermal emitter plus a band pass filter to make the thermal emitter behave like a selective emitter. Results of the comparison indicate that only for very optimistic filter and thermal emitter properties will the filter ...

1990-05-01

303

High performance fiber filtration and its fluid flow  

Energy Technology Data Exchange (ETDEWEB)

A new filtration process using acrylic fiber has been developed which has wide applications in water works, sewage water treatment and waste water treatment facilities. Instead of sand, the common filter media in conventional systems, this new system uses long, fine acrylic fibers. Compared with a conventional system, the filtration speed and suspended solids (SS) retention of the new system have been increased 500% from 120--200 m/d to 400--1,200 m/d and from 2--3 kg/m{sup 2} to 5--20 kg/m{sup 2}, respectively. In addition, the backwash time has been decreased 60%, from 20--30 min to 10 min. As SS retention increase, the empty space between the fibers (fiber void) decreases and pressure drops due to the high filtration rate. Thus the pressure decreases rapidly after a certain period of filtration because of the increased SS retention cause fiber compression. This system is primarily based on solution clarification, but differs in that the fiber ...

1994-12-31

304

Decontamination performance in off-gas cleaning system of radioactive solid waste incineration unit  

International Nuclear Information System (INIS)

At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the docontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined as the ratio of radioactivities input to the furnace to ...

305

Crud behaviors and water chemistry in nuclear reactors  

International Nuclear Information System (INIS)

The deposit of radioactive corrosion products in the cooling systems of nuclear reactors becomes a serious problem for the personnel of facilities. Crud has an important role in the process of depositing radioactive corrosion products. The main components of crud are hematite, magnetite, nickel ferrite and so on, and the particles of these oxide compounds are distributed in water. Most of the behavior of crud are still not known. As for the mechanism of the production of crud, the Potter-Mann model has been proposed. However, the precipitation process of iron ions in water is unknown. The crud is defined as the particles filtered by 0.45 micrometer millipore filters. However, it is not known whether there are crud particles smaller than this size. The crud particles can be adsorbed on the filters by the surface electrochemical interaction. The adsorption of cations to crud particles was studied. The adhesion of crud ...

306

Argentinian doctors accused of spreading AIDS.  

Science.gov (United States)

The provincial ministry of health has taken over a dialysis center in La Plata, Argentina, following the discovery that at least 20 of the clinic's 34 regular patients have been infected with the human immunodeficiency virus (HIV). Catheters of the clinic's dialysis machines were found to be contaminated with HIV. The 5 physicians associated with the Centro Modelo de Dialisis have been discharged for negligence. 20 of the regular patients also contracted hepatitis C. Argentinian law stipulates that filters for the same patient must be changed after 4 times and prohibits the use of the same vessel to administer medication to more than 1 patient. Testimony from nurses at the La Plata clinic revealed that filters were reused for several patients and basic sanitary procedures were not followed. In 1990, 33 kidney disease patients at a dialysis center in Cordoba became infected with HIV and it was discovered that filters ...

1993-09-01

307

An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.  

Science.gov (United States)

A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems ...

2010-07-19

308

Understanding collaborative filtering parameters for personalized recommendations in e-commerce  

British Library Electronic Table of Contents (United Kingdom)

Collaborative Filtering (CF) is a popular method for personalizing product recommendations for e-Commerce and customer relationship management (CRM). CF utilizes the explicit or implicit product evaluation ratings of customers to develop personalized recommendations. However, there has been no in-depth investigation of the parameters of CF in relation to the number of ratings on the part of an individual customer and the total number of ratings for an item. We empirically investigated the relationships between these two parameters and CF performance, using two publicly available data sets, EachMovie and MovieLens. We conducted three experiments. The first two investigated the relationship between a particular customer?s number of ratings and CF recommendation performance. The third experim...

2007-01-01

309

Selective association rule generation  

CERN Document Server

Mining association rules is a popular and well researched method for discovering interesting relations between variables in large databases. A practical problem is that at medium to low support values often a large number of frequent itemsets and an even larger number of association rules are found in a database. A widely used approach is to gradually increase minimum support and minimum confidence or to filter the found rules using increasingly strict constraints on additional measures of interestingness until the set of rules found is reduced to a manageable size. In this paper we describe a different approach which is based on the idea to first define a set of ``interesting'' itemsets (e.g., by a mixture of mining and expert knowledge) and then, in a second step to selectively generate rules for only these itemsets. The main advantage of this approach over increasing thresholds or filtering rules is that the number of rules found is ...

2008-01-01

310

Manufacturing of Austenitic Stainless Steel-Zirconia Composites by Infiltration  

British Library Electronic Table of Contents (United Kingdom)

Abstract Within the framework of the CRC 799 -TRIP-Matrix-Composites- at the TU Bergakademie Freiberg new composite materials consisting of TRIP steel and zirconium dioxide ceramics are designed in a powder route and a casting route. To manufacture faultless samples basic investigations of the feeding and infiltration behaviour within macro porous ceramics such as filters were needed. The effects of bottom pouring and top pouring were investigated as well as the effects of different preheating temperatures, contents of phosphorous in the steel and flow trough rates. Bottom pouring corrupts the feeding mainly of filters with high ppi (pores per inch). Top pouring improves the feeding, but generates inhomogeneous infiltration qualities, which can affected and enhanced by a increasing preheat...

2011-01-01

311

Investigation of the removal efficiency of gasborne particles in a scrubber column  

Energy Technology Data Exchange (ETDEWEB)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 ..mu..m; drops of diameter size 1.5 ..mu..m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water.

1983-01-01

312

Investigation of the removal efficiency of gasborne particles in a scrubber column  

International Nuclear Information System (INIS)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 #mu#m; drops of diameter size 1.5 #mu#m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water. (orig.).

313

Identification of prostate cancer antigens by automated high-throughput filter immunoscreening  

British Library Electronic Table of Contents (United Kingdom)

There is a need for earlier and more accurate cancer diagnostics as well as new targets for cancer immunotherapy. To this end, it is important to identify sets of tumour antigens specific for different cancer forms. Several methods that identify potential tumour antigens in an arrayed and high-throughput format have been developed during the last years of SEREX (serological identification of antigens by recombinant expression cloning) related research. Such techniques may hold the potential to describe the complete immunogenic part of the cancer proteome, also called the cancer immunoproteome.We have developed a powerful platform for automated serological high-throughput filter screening of tumour cDNA libraries. The screening format of this method is 18,000 single cDNAs clones, which is s...

2008-01-01

314

High frequency converters for thermophotovoltaic applications  

Energy Technology Data Exchange (ETDEWEB)

Thermophotovoltaic (TPV) converters were developed and tested at the heat source operating temperature of 1,700 K. Rare-earth-doped yttrium aluminum garnet (YAG) and lutetium yttrium aluminum garnet (Lu, YAG) selective emitters, as well as a blackbody emitter, were coupled to InGaAs/InP photovoltaic (PV) cells and bandpass/infrared (IR) reflector filters. YAG-based selective emitters were adopted with Ho, Tm, and Er. PV cells had bandgaps of 0.51, 0.57, and 0.69 eV. Converter energy conversion efficiencies approaching 30%, as well as electrical output power densities near 2 W/cm{sup 2} were demonstrated. The overall performance of the filtered blackbody-based converter was found to be superior to the selective emitter YAG-based converters. The details of the measurements performed on the above converters and their individual components are presented.

1996-12-31

315

Evaluation of Capiox FX05 Oxygenator With an Integrated Arterial Filter on Trapping Gaseous Microemboli and Pressure Drop With Open and Closed Purge Line  

British Library Electronic Table of Contents (United Kingdom)

Abstract Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass (CPB) because there is a positive correlation between microemboli exposure during CPB and postoperative neurological injury. Thus, minimizing the number of GME delivered to pediatric patients undergoing CPB procedures would lead to better clinical outcomes. In this study, we used a simulated CPB model to evaluate the effectiveness of capturing GME and the degree of membrane pressure drop for a new membrane oxygenator, Capiox Baby FX05 (Terumo Corporation, Tokyo, Japan), which has an integrated arterial filter with open and closed purge line. We used identical components in this study as our clinical CPB circuit. Three emboli detection and classification quantifier transducers were placed at prepump, preoxygena...

2010-01-01

316

Development of magnet power supply for J-PARC 50-GEV synchrotron  

International Nuclear Information System (INIS)

A new magnet power supply system for J-PARC 50GeV Synchrotron is proposed as solutions both in the power capacity and in the precision at the same time. The developed 10MW class magnet power supply consists of the advanced self-commutated current-source type converter (ACSC) using the new device IEGT rated at 4500V-2100A and the ''hybrid filter'' including the variable impedance filter with the equivalent 16 kHz switching. With 1/16 scale-model system using a prototype bending magnet, the experimental results showed the current ripple less than 1 x 10"-"6 and the tracking error less than #+-#0.5 x 10"-"4. (author)

2004-08-04

317

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

318

Correlation, hierarchies, and networks in financial markets  

CERN Document Server

We discuss some methods to quantitatively investigate the properties of correlation matrices. Correlation matrices play an important role in portfolio optimization and in several other quantitative descriptions of asset price dynamics in financial markets. Specifically, we discuss how to define and obtain hierarchical trees, correlation based trees and networks from a correlation matrix. The hierarchical clustering and other procedures performed on the correlation matrix to detect statistically reliable aspects of the correlation matrix are seen as filtering procedures of the correlation matrix. We also discuss a method to associate a hierarchically nested factor model to a hierarchical tree obtained from a correlation matrix. The information retained in filtering procedures and its stability with respect to statistical fluctuations is quantified by using the Kullback-Leibler distance.

2008-01-01

319

Consumption of filtered and boiled coffee and the risk of incident cancer: a prospective cohort study  

British Library Electronic Table of Contents (United Kingdom)

Background Despite potentially relevant chemical differences between filtered and boiled coffee, this study is the first to investigate consumption in relation to the risk of incident cancer. Methods Subjects were from the V?sterbotten Intervention Project (64,603 participants, including 3,034 cases), with up to 15?years of follow-up. Hazard ratios (HR) were calculated by multivariate Cox regression. Results No associations were found for all cancer sites combined, or for prostate or colorectal cancer. For breast cancer, boiled coffee ?4 versus <1 occasions/day was associated with a reduced risk (HR?=?0.52, CI?=?0.30?0.88, p trend?=?0.247). An increased risk of premenopausal and a reduced risk of postmenopausal breast cancer were found for both total (HRpremenopausal?=?1.69, CI?=?0.96?2.98...

2010-01-01

320

Applications of nanomaterials in environmental protection; Untersuchung des Einsatzes von Nanomaterialien im Umweltschutz  

Energy Technology Data Exchange (ETDEWEB)

Following comprehensive research nanomaterials or products which were either still in a re-search/development status or are already available in the marketplace were identified for the water and air sectors. Based on life cycle assessments for two case studies, it was checked how the potential benefits and impacts on the environment for nanotechnology products or processes compare with those for conventional solutions. The first case study deals with the solar treatment of water contami-nated with tetrachloroethylene, comparing nanoscale titanium dioxide (photo-catalysis) and a photo-Fenton process. The second case study on air filtration compares a passenger car cabin-air filter with nanofibres and a conventional filter. (orig.)

2010-06-15

321

Application of Vertically Integrated Electronics to Intelligent Trackers  

CERN Document Server

At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

2010-01-01

322

A novel volumetric method for quantitation of titanium dioxide in cosmetics  

British Library Electronic Table of Contents (United Kingdom)

Nowadays there are many sun-protection cosmetics incorporating organic or inorganic UV filters as active ingredients. Chemically stable inorganic sunscreen agents, usually metal oxides, are widely employed in high-SPF (sun protection factor) products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as a pigment for a long period of cosmetic history. With the development of micronization techniques, it has become possible to incorporate titanium dioxide in sunscreen formulations without the previous whitening effect, and hence its use in cosmetics has become an important research topic. However, there are very few works related to quantitation of titanium dioxide in sunscreen products. In this research, we analysed the amounts of titanium dioxide i...

2007-01-01

323

A hybrid time-frequency method based on improved Morlet wavelet and auto terms window  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a hybrid time-frequency method (HTM) based on the improved Morlet wavelet and auto terms window (ATW) is presented. The Morlet wavelet, for its shape is similar to the mechanical shock signals, is added two parameters which decide the shape of the mother wavelet. The added parameters and the appropriate scale parameter for continuous wavelet transformation (CWT) are calculated using the cross validation method (CVM) and the minimum Shannon entropy method. The useless noise in the original signal can be filtered by the CWT filter de-noising process. An ATW based on the Smoothed Pseudo Wigner-Ville Distribution (SPWVD) spectrum is designed as a window function to suppress the cross terms in Wigner-Ville Distribution (WVD). The gear fault diagnosis experiment results show that ...

2011-01-01

324

A Study on Feature Selection Techniques in Educational Data Mining  

CERN Document Server

Educational data mining (EDM) is a new growing research area and the essence of data mining concepts are used in the educational field for the purpose of extracting useful information on the behaviors of students in the learning process. In this EDM, feature selection is to be made for the generation of subset of candidate variables. As the feature selection influences the predictive accuracy of any performance model, it is essential to study elaborately the effectiveness of student performance model in connection with feature selection techniques. In this connection, the present study is devoted not only to investigate the most relevant subset features with minimum cardinality for achieving high predictive performance by adopting various filtered feature selection techniques in data mining but also to evaluate the goodness of subsets with different cardinalities and the quality of six filtered feature selection algorithms in terms of F-measure ...

2009-01-01

325

Sensitivity analysis and development of calibration methodology for near-surface hydrogeology model of Laxemar  

Energy Technology Data Exchange (ETDEWEB)

This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...

2007-11-15

326

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...

2001-06-17

327

Vehicle Emissions Team diesel particulate filter sub-group : final report  

Energy Technology Data Exchange (ETDEWEB)

In 2003, Vehicle Emissions Team of the Clean Air Strategic Alliance (CASA) decided to explore ways to reduce vehicle emissions such as particulate matter, nitrogen oxides, carbon monoxide, and hydrocarbons from diesel engines. One of the options for reducing emissions from diesel engines, a diesel particulate filter (DPF), is the subject of a demonstration project to test the effectiveness of the Johnson Matthey diesel particulate filter called Continuously Regenerating Technology (CRT) under cold weather conditions. The project involved filter testing between January 2003 and January 2004 on two diesel buses in Edmonton Transit System's (ETS) fleet. Vehicle exhaust emissions were tested for total hydrocarbons, nitrogen oxides, carbon monoxide, carbon dioxide, and particulate matter. The objectives of the project were to: prove the effectiveness of DPF under cold weather conditions in Alberta; provide an ...

2004-09-16

328

The denoising of Monte Carlo dose distributions using convolution superposition calculations  

International Nuclear Information System (INIS)

Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to ...

2007-09-07

329

Swift Observations of GRB 070318 - GCN - NASA  

Science.gov (United States)

Apr 16, 2007 ... with a 1-sigma error radius of about 0.5 arc sec. ... It was consistent with a single point source at: RA (J2000) = 03h 13m 57.6s ... At 13000 sec. after the trigger, the magnitude in the UVOT B filter was ~19.9 with a ...

330

Sweden employs a multi venturi scrubber for containment venting  

Energy Technology Data Exchange (ETDEWEB)

The Filtra-MVSS for filtered venting of containment overpressure is a flexible system capable of covering a wide range of hypothetical design basis events for BWRs and PWRs. The system encompasses a number of special features, can be optimized for a specified decontamination factor, and can accommodate a wide range of off-gas flow rates.

1988-03-01

331

Structural features and types of collectors of productive formations of the North Saremboyskiy field  

Energy Technology Data Exchange (ETDEWEB)

An examination is made of the structure of the North Saremboyskiy oil field and productive lower Devonian deposits of well 15. Based on detailed lithological studies, as well as investigation of filtering-capacitance properties of rocks, the complex structure of the carbonate deposits and the dominant development of complex type collectors is indicated.

1982-01-01

332

Solar Eclipse Images - SDAC Home Page - NASA  

Science.gov (United States)

Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...

333

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...

2006-07-01

334

Red mud and sands handling: New thoughts on an old problem  

Energy Technology Data Exchange (ETDEWEB)

The alumina industry is facing worldwide a growing disposal problem. Red mud creates increasingly technical, economic and environmental problems. Available solutions are reviewed and an old idea using a new approach with pressurized disc or drum filters for red mud is herewith presented and submitted for consideration as a potential and prospective solution to the problem.

1996-10-01

335

Recent process developments at the COMINAK uranium mill  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews the mill flowsheet applied at the COMINAK uranium mill (Compagnie Miniere d'Akouta) in Niger. For ore treatment, it focuses on the major improvements to the operations using sulfonitric pugging and solids/liquid separation using belt filter double filtration after leaching. The precipitation circuits have been improved with molybdenum elimination through caustic washing of the yellow cake. (author)

2000-07-01

336

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

337

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

338

Process for uranium processing  

International Nuclear Information System (INIS)

To the crushed ore leaching is applied. The resulting solid-liquid mixture is fed to a hydro-cyclon grading facility; here the superfine grain is separated before the concentrated mixture can be filtered or centrifuged. The grading is done in several steps. From the liquid, ultimately ridded of the solid, uranium compounds are precipitated and the yellow cake is obtained. (DG).

1984-11-12

339

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

340

Predictive wavefront control for Adaptive Optics with arbitrary control loop delays  

Energy Technology Data Exchange (ETDEWEB)

We present a modification of the closed-loop state space model for AO control which allows delays that are a non-integer multiple of the system frame rate. We derive the new forms of the Predictive Fourier Control Kalman filters for arbitrary delays and show that they are linear combinations of the whole-frame delay terms. This structure of the controller is independent of the delay. System stability margins and residual error variance both transition gracefully between integer-frame delays.

2007-10-30

341

Practical Aspects of Kalman Filtering Implementation  

Science.gov (United States)

... L z xyx 0 0 0 0 0 0 0 0 0 0 0 0 -V 0 0 0 0 oj A ~ 0 0 1 0 v 0 I - z Fiue2. Inertial Navigation Error Lquation-i in the Platform Frame t 'I A Page 35. ...

1976-03-01

342

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

343

Optimal Knot Selection for Least-squares Fitting of Noisy Data with Spline Functions  

Energy Technology Data Exchange (ETDEWEB)

An automatic data-smoothing algorithm for data from digital oscilloscopes is described. The algorithm adjusts the bandwidth of the filtering as a function of time to provide minimum mean squared error at each time. It produces an estimate of the root-mean-square error as a function of time and does so without any statistical assumptions about the unknown signal. The algorithm is based on least-squares fitting to the data of cubic spline functions.

2008-05-15

344

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

345

On some problems caused by wavelet filtering in calculated spectra  

Energy Technology Data Exchange (ETDEWEB)

It is shown that de-noising a measured time signal by wavelet technique produces a rather good result in time domain, while it has unwanted consequences in spectrum estimation. Therefore it can be used for reconstruction of the picture of the physical process, but it should be avoided, when the aim is to reveal eigenfrequencies or transient behaviour of the spectra.

1999-08-01

346

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

347

Nine-component vertical seismic profiling at Yucca Mountain, Nevada  

Energy Technology Data Exchange (ETDEWEB)

Nine-component vertical seismic profiling has been conducted at the UE-25 UZ No. 16 borehole at Yucca Mountain, Nevada, in support of investigation of the hydrologic significance of fault and fracture systems. A large data set from multi-component sources and receivers allows state-of-the-art advances in processing using polarization filtering and reverse time migration, for enhanced interpretation of geologic features.

1996-12-01

348

Nine-component vertical seismic profiling at Yucca Mountain, Nevada  

International Nuclear Information System (INIS)

Nine-component vertical seismic profiling has been conducted at the UE-25 UZ No. 16 borehole at Yucca Mountain, Nevada, in support of investigation of the hydrologic significance of fault and fracture systems. A large data set from multi-component sources and receivers allows state-of-the-art advances in processing using polarization filtering and reverse time migration, for enhanced interpretation of geologic features.

349

Nanophotonic components utilizing channel plasmon polaritons  

Science.gov (United States)

Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.

2008-08-01

350

Method for the elimination of simple organic compounds by filtration on activated-charcoal particles  

Energy Technology Data Exchange (ETDEWEB)

The use of filters of activated-charcoal particles in drinking-water purification plants assists in the elimination of organic micropollutant substances. The authors report on a study which sought to investigate the mechanism of organic matter; they describe the experimental programme, which used different size ranges of mineral-based activated charcoal, present the experimental findings and discuss the results. 16 references.

1984-12-01

351

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

352

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

353

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment  

Energy Technology Data Exchange (ETDEWEB)

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality ...

2009-01-29

354

I_ 66- 1 Z_5 27 _O - NASA Technical Report Server (NTRS)  

Science.gov (United States)

sigma confidence of hitting a 21 km atmospheric entry corridor ...... end-point state and the end time f(X,T). (2-27) where X = Nominal end-point state. T = Nominal ..... which assumes a linear filter is given in Reference. 2 to- ...

355

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

356

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

357

FastBit -- Helps Finding the Proverbial Needle in a Haystack  

Energy Technology Data Exchange (ETDEWEB)

FastBit is a software package designed to meet the searching and filtering needs of data intensive sciences. In these applications, scientists are trying to find nuggets of information from petabytes of raw data. FastBit has been demonstrated to be an order of magnitude faster than comparable technologies. In this brief report, we highlight how we work with a visualization team, a network security team and a DNA sequencing center to find the nuggets in their data.

2006-07-05

358

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.

2001-03-23

359

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.

2000-01-24

360

Cobalt and organics removal effect using fiber filter/reverse osmosis combination process for LLRW from korean PWR NPP  

Energy Technology Data Exchange (ETDEWEB)

Evaporation system for liquid radioactive waste process has been used in Korean PWR nuclear power plants. The system is the most desirable process for decontamination factor (DF) theoretically. However, during the operation of the system, various problems have been arising such as scaling, carry over, etc. Because these problems make DF low, advanced technologies for liquid radwaste process have been world widely developed instead of keeping evaporation system. The main goal of new technologies is ALARA, ease of operation, cost effectiveness and minimization of environmental effect. Korea Electric Power Corporation is currently developing a combined treatment process for liquid radwaste using Micro-filter, Ultra-filter, Reverse Osmosis (RO) membrane, etc for the purpose of partly enhancement of evaporator and of having an alternative liquid radwaste process system for new reactors. As a part of the above project, the feasibility study using the ...

2001-07-01

361

Assessment of the efficacy of braking radiation beam formation of electron accelerators  

International Nuclear Information System (INIS)

Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.

362

Analysis of longitudinal bunching in an FEL driven two-beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

2000-08-01

363

West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes  

Energy Technology Data Exchange (ETDEWEB)

Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...

1994-05-01

364

Using calibrated engineering models to predict energy savings in large-scale geothermal heat pump projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-10-01

365

Using Calibrated Engineering Models To Predict Energy Savings In Large-Scale Geothermal Heat Pump Projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-01-01

366

Type Ia supernova science 2010-2020  

CERN Document Server

In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0

2009-01-01

367

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...

1995-12-31

368

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...

2009-09-14

369

Simultaneous determination of dorzolamide HCL and timolol maleate in eye drops by two different spectroscopic methods.  

Science.gov (United States)

Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...

2002-04-15

370

Quantification of the local glucose utilization and local blood flow in the heart of the awake rat using the /sup 14/C-2-deoxyglucose and /sup 14/C-iodoantipyrine methods  

Science.gov (United States)

Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.

1986-03-05

371

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

372

Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument  

Science.gov (United States)

The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...

2006-05-01

373

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...

1977-11-01

374

Life Under Your Feet: An End-to-End Soil Ecology Sensor Network, Database, Web Server, and Analysis Service  

CERN Document Server

Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...

2007-01-01

375

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-07-01

376

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-05-10

377

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...

1978-04-01

378

Determination of binary mixtures of analgesic and spasmolytic drugs in pure and dosage forms by derivative spectrophotometry.  

Science.gov (United States)

Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...

2003-10-15

379

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...

2008-01-16

380

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...

2007-08-01

381

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

Energy Technology Data Exchange (ETDEWEB)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-15

382

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

International Nuclear Information System (INIS)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-01

383

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

Energy Technology Data Exchange (ETDEWEB)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.

2005-02-15

384

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

International Nuclear Information System (INIS)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.

2005-02-01

385

A proposed methodology for computational fluid dynamics code verification, calibration, and validation  

Energy Technology Data Exchange (ETDEWEB)

Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...

1995-07-01

386

Yucca Mountain Task 4, Final report FY 1993  

Energy Technology Data Exchange (ETDEWEB)

Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.

1993-09-30

387

VDMA contribution to functional safety of turbo-machines - A necessary risk reduction by means of safety function for steam turbines; VDMA-Beitrag zur Funktionalen Sicherheit von Turbomaschinen. Notwendige Risikoreduktion durch Schutzfunktionen fuer Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.

2010-07-01

388

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

389

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

390

Reliable dates for the last 50.000 years; Des dates fiables pour les 50 000 dernieres annees  

Energy Technology Data Exchange (ETDEWEB)

The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)

2004-03-01

391

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

392

Proceedings of the fourth international airborne remote sensing conference and exhibition/ 21st Canadian symposium on remote sensing  

Energy Technology Data Exchange (ETDEWEB)

The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.

1999-07-01

393

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

394

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

395

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

396

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

397

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

398

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

399

In situ observation of axial irradiation growth in liquid-metal reactor metal fuel  

International Nuclear Information System (INIS)

Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.

1989-11-26

400

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

401

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

402

Experimental Uncertainty for the Thermal Expansion of a Simulated Fuel  

Energy Technology Data Exchange (ETDEWEB)

Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.

2006-07-01

403

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

404

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

405

Determining nuclear morphology using an improved angle-resolved low coherence interferometry system  

Science.gov (United States)

We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.

2003-12-01

406

Dependence of thermal plasma jet temperature on discharge power and gas flow rate  

International Nuclear Information System (INIS)

With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)

2008-03-01

407

Beam position monitor readout and control in the SLC linac  

Energy Technology Data Exchange (ETDEWEB)

A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.

1985-04-01

408

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

409

A theoretical study of radon measurement with activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.

1998-04-11

410

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...

1988-08-01

411

Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...

2005-05-13

412

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...

2007-08-01

413

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1997-01-05

414

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1996-09-01

415

WWW expert system on producer gas cleaning  

Energy Technology Data Exchange (ETDEWEB)

The University of Groningen (RUG) has developed an expert system on cleaning of biomass producer gas. This work was carried out in close co-operation with the Biomass Technology Group B.V. (BTG) in Enschede, The Netherlands within the framework of the EC supported JOR3-CT95-0084 project. The expert system was developed as a tool for the designer-engineer of downstream gas cleaning equipment and consists of an information package and a flowsheet package. The packages are integrated in a client/server system. The flowsheeting package of the expert system has been designed for the evaluation of different gas cleaning methods. The system contains a number of possible gas cleaning devices such as: cyclone, fabric filter, ceramic filter, venturi scrubber and catalytic cracker. The user can select up to five cleaning steps in an arbitrary order for his specific gas cleaning problem. After specification of the required design parameters, the system ...

1999-07-01

416

Ultratrace analysis of mercury and methylmercury (MM) in rain water using cold vapor atomic absorption spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Ultratrace analysis of mercury in rain water has been investigated, including recovery of ionic mercury with the addition of acids, treatment and storage and stability studies of mercury in rain water. Recovery of ionic mercury from rain water samples increased with increased acid concentrations and increased substantially with UV-irradiation. Recovery of ionic mercury in the presence of different acids was compared. Treatment studies of rain water for the analysis of total mercury were done using different decomposition methods. More than 20% of the total mercury was found in rain water residue after filtration through 0.45 ..mu..m membrane filters. Methylmercury (MM) content in filtered and unfiltered rain water however was nearly the same. On long term storage of rain water without acids at pH = 2.0 and 4.5 loss of total mercury occurred, but in the presence of acids increasing amounts of ionic mercury were recovered from rain water samples ...

1987-03-01

417

Trapping technology for gaseous fission products from voloxidation process  

Energy Technology Data Exchange (ETDEWEB)

The objective of this report is to review the different technologies for trapping the gaseous wastes containing Cs, Ru, Tc, {sup 14}C, Kr, Xe, I and {sup 3}H from a voloxidation process. Based on literature reviews and KAERI's experimental results on the gaseous fission products trapping, appropriate trapping method for each fission product has been selected considering process reliability, simplicity, decontamination factor, availability, and disposal. Specifically, the most promising trapping method for each fission product has been proposed for the development of the INL off-gas trapping system. A fly ash filter is proposed as a trapping media for a cesium trapping unit. In addition, a calcium filter is proposed as a trapping media for ruthenium, technetium, and {sup 14}C trapping unit. In case of I trapping unit, AgX is proposed. For Kr and Xe, adsorption on solid is proposed. SDBC (Styrene Divinyl Benzene Copolymer) is also ...

2005-05-15

418

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATION  

Energy Technology Data Exchange (ETDEWEB)

This report describes experimental results for the selective removal of strontium and cesium from simulated waste solutions using monosodium titanate (MST) and crystalline silicotitanate (CST)-laden filter cartridges. Four types of ion exchange cartridge media (CST and MST designed by both 3M and POROX{reg_sign}) were evaluated. In these proof-of-principle tests effective uptake of both Sr-85 and Cs-137 was observed. However, the experiments were not performed long enough to determine the saturation levels or breakthrough curve for each filter cartridge. POREX{reg_sign} MST cartridges, which by design were based on co-sintering of the active titanates with polyethylene particles, seem to perform as well as the 3M-designed MST cartridges (impregnated filter membrane design) in the uptake of strontium. At low salt simulant conditions (0.29 M Na{sup +}), the instantaneous decontamination factor (D{sub F}) for Sr-85 with the ...

2011-05-26

419

Production of a cellulolytic enzyme system in mixed-culture solid-state fermentation of soybean hulls supplemented with wheat bran  

British Library Electronic Table of Contents (United Kingdom)

Solid-state fermentation of soybean hulls supplemented with wheat bran using a co-culture of Trichoderma reesei and Aspergillus oryzae was performed. Three parameters - initial moisture content, incubation temperature, and initial pH - were optimized in culture flasks using response surface methodology. Parameter optimization was carried out with respect to filter paper activity and b-glucosidase activity in the culture. Temperature of 30^oC, pH of 5, and moisture content of 70% were found to be optimum. Optimized parameters were used for laboratory scale-up in static tray fermenters. The maximum filter paper activity of 10.7FPU/g-ds and b-glucosidase of 10.7IU/g-ds were obtained after 96-h incubation period in static tray fermenters in agreement with optimized activities at shake flask le...

2010-01-01

420

PDE-based Non-Linear Diffusion Techniques for Denoising Scientific and Industrial Images: An Empirical Study  

Energy Technology Data Exchange (ETDEWEB)

Removing noise from data is often the first step in data analysis. Denoising techniques should not only reduce the noise, but do so without blurring or changing the location of the edges. Many approaches have been proposed to accomplish this; in this paper, they focus on one such approach, namely the use of non-linear diffusion operators. This approach has been studied extensively from a theoretical viewpoint ever since the 1987 work of Perona and Malik showed that non-linear filters outperformed the more traditional linear Canny edge detector. They complement this theoretical work by investigating the performance of several isotropic diffusion operators on test images from scientific domains. They explore the effects of various parameters such as the choice of diffusivity function, explicit and implicit methods for the discretization of the PDE, and approaches for the spatial discretization of the non-linear operator etc. They also compare these schemes with ...

2001-12-20

421

Observation of the limit cycle in the asymmetric plasma divided by the magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

Asymmetric plasma divided by the magnetic filter (MF) is numerically simulated by the one-dimensional particle-in-cell code VSIM1D. Depending on the asymmetry, the system behaves static or dynamic. In the static state, the potentials of the main plasma and the sub-plasma are given by the sheath potentials, {phi}{sub M} - 3T{sub Me}/e and {phi}{sub S} - 3T{sub Se}/e, respectively, with e being an electron charge and T{sub Me} and T{sub Se} being electron temperatures (T{sub Me} > T{sub Se}). In the dynamics state, while {phi}{sub M} - 3T{sub Me}/e, {phi}{sub S} oscillates periodically between {phi}{sub S,min} - 3T{sub Se}/e and {phi}{sub S,max} - 3T{sub Me}/e. The ions accelerated by the time varying potential gap get into the sub-plasma and excite the laminar shock waves. This periodic phenomenon can be understood as a limit cycle due to transitions between two bifurcated states of {phi}{sub S,min} and {phi}{sub S,max}. (author)

2000-08-01

422

Local composition analysis of SiC microstructures formed by ion projection in silicon using energy filtered TEM in combination with FIB specimen preparation  

International Nuclear Information System (INIS)

Buried silicon carbide (SiC) microstructures with lateral dimensions in the #mu#m range were formed by high-dose projection of 1.5 MeV C"2"+ ions in Si(100) at different doses and temperatures and subsequent annealing for 10 h at 1250 deg. C. Sections of individual SiC microstructures were prepared for cross-sectional transmission electron microscopy (TEM) analysis using a focused ion beam (FIB). Besides the possibility to select an individual microstructure, the FIB technique has the advantage of producing specimen foils of uniform thickness. Therefore, it was possible to map the carbon concentration of microstructures by energy filtered TEM (EFTEM) using the C_K absorption edge without the need of any sample thickness correction. Local overstoichiometric (>50%) carbon concentrations are shown to be correlated to the formation of an amorphous phase in the SiC and to significant swelling visible at the Si wafer surface 2 #mu#m above.

2003-09-15

423

Kinetic aspects of the photolysis of in-station airborne methyl iodide  

International Nuclear Information System (INIS)

A method for converting organic iodides to elemental iodine would be advantageous in improving the performance of charcoal filters for the removal of radio iodines from reactor off gases. A photochemical method has been developed. The HAVCHM code was used to establish the relevant process time scales on a complete set of rate equations describing the primary and secondary reactions occurring in a plug-flow reactor containing low levels of elemental iodine and methyl iodide in air, which is irradiated by intense u.v. light. These simulations were used to justify the contraction of the complete set of reactions to the most significant elementary processes. The contracted set of rate equations are then solved analytically to render the concentration-time profiles of methyl iodide, total inorganic iodine and total oxidized organics, consistent with the achievement of a desirable radioiodine decontamination factor. For the short contact times available, the flux of ...

424

High temperature aluminum electrolytic capacitors for ULEV inverters  

Energy Technology Data Exchange (ETDEWEB)

A comparison between the concepts of the hybrid electric vehicle (HEV) and the ultra low emission vehicle (ULEV) was presented. The ULEV uses a much larger engine compared to the HEV, but it uses a lower Kw generator/motor and inverter/charger to use the latest engine and battery technology. The underlying goal of the ULEV is to supply auxiliary power under start-up and heavy load conditions and to remove indirect systems such as steering, starting and blower control from the engine via small electric drives. The challenge is to build a ULEV that is robust enough to withstand any environmental conditions. Since the ULEV engine is larger, it can experience compartment temperatures greater than 125 degrees C, which limits the use of conventional filter capacitors. Nippon Chemi-Con has recently developed U787D, the world's first continuous 150 degrees C rated aluminum electrolytic capacitor designed to meet the ambient, ripple currents and vibration ...

2000-07-01

425

High efficiency direct thermal to electric energy conversion from radioisotope decay using selective emitters and spectrally tuned solar cells  

International Nuclear Information System (INIS)

Thermophotovoltaic (TPV) systems are attractive possibilities for direct thermal-to-electric energy conversion, but have typically required the use of black body radiators operating at high temperatures. Recent advances in both the understanding and performance of solid rare-earth oxide selective emitters make possible the use of TPV at temperatures as low as 1200K. Both selective emitter and filter system TPV systems are feasible. However, requirements on the filter system are severe in order to attain high efficiency. A thin-film of a rare-earth oxide is one method for producing an efficient, rugged selective emitter. An efficiency of 0.14 and power density of 9.2 W/KG at 1200K is calculated for a hypothetical thin-film neodymia (Nd2O3) selective emitter TPV system that uses radioisotope decay as the thermal energy source.

1993-08-23

426

Fast Implementation of Matched Filter Based Automatic Alignment Image Processing  

Energy Technology Data Exchange (ETDEWEB)

Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field programmable logic array (FPGA) to speed up these computations. The results indicate a performance improvement of 20 using the FPGA ...

2008-04-02

427

Energy-filtered electron microscopy for imaging core-shell nanostructures  

Energy Technology Data Exchange (ETDEWEB)

CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the core-shell arrangements in the nanoparticle ...

2008-08-15

428

Energy and exergy analyses of malt drink production in Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Energy requirements and exergy inefficiencies for processing of malt drink were estimated for a Nigerian brewery. The process was divided into twenty-one basic unit operations and grouped into four main group operations: silo house, brew house, filter room and packaging house. The energy intensity for processing a batch of 9.8 tonnes brew grains to 562 hl of malt drink was estimated as 261.63 MJ/hl consisting of electrical (41.01%), thermal (58.81%) and manual (0.19%) of the total energy. The most energy intensive group operation was the Packaging House operation, followed by the Brew House operation with energy intensities of 223.19 and 35.94 MJ/hl, respectively. The exergy analysis revealed that the packaging house operation was responsible for most of the inefficiency (92.16%) followed by brew house operation (7.17%) and the silo house and filter room operations with less than 1% of the total exergy lost. The most exergy loss took place in ...

2010-12-15

429

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of complicating factors such as solar ...

1997-08-01

430

EDF waste packages transport and compliance with regulations: prediction of retention of radionuclides by cementitious materials  

International Nuclear Information System (INIS)

Different concrete waste packages have been designed by Electricite de France (EDF) for the long-term storage of radioactive Low Level Waste (LLW). Their main function is to confine radionuclides from the biosphere for three hundred years in a near-surface disposal. According to the transport regulations, a Type-B package is needed for some waste like water filters. The water filters from EDF nuclear power plants are encapsulated in mortar and placed in a concrete container. Transport regulations for these containers have required the development of a methodology for safety assessment. The reference scenario of container degradation during transport considers a 9 m drop and a 800"oC fire for 30 min. First, the different chemical and physical processes involved in the containment of radionuclides are analysed. In particular, the radionuclide transport mechanisms in cement-based materials have been reviewed. Secondly, the effects of a container ...

431

Diminished osmotic fragility of human erythrocytes following the membrane insertion of oxygenated sterol compounds  

Energy Technology Data Exchange (ETDEWEB)

Oxygenated sterol compounds (OSC), when incubated for 1 hr with human erythrocytes in lipoprotein-depleted medium at concentrations of 0.625-5 x 10/sup -5/M, are inserted into the cell membrane and remain there despite subsequent washing of the cells. The insertion results in expansion of the surface area of the red cell ghost membrane, an increase in critical hemolytic volume, and as a consequence, in dimished osmotic fragility of the erythrocytes. This effect is seen with echinocyte-forming as well as with non-echinocyte-forming OSC. Erythrocytes treated with OSC do not differ from control cells with respect to their mean cell volume (MCV) in isotonic solution, water content, ion fluxes, and filterability through polycarbonate filters. The shift of the osmotic fragility curve toward lower NaCl concentrations is proportional to the amount of OSC inserted into the red cell membrane. 7BETA-Hydroxycholesterol, 22-ketocholesterol, and 20 ..cap ...

1981-08-01

432

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was trapped in the magnetic filter under an external magnetic field of ...

2009-10-15

433

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the ...

434

Unitizations of double-ring structure and Erbium-doped waveguide amplifier for stable and tunable fiber laser  

British Library Electronic Table of Contents (United Kingdom)

We propose and demonstrate experimentally a singlelongitudinal-mode (SLM) fiber double-ring laser using an Erbium-doped waveguide amplifier (EDWA), polarization controller (PC), and a fiber Fabry-Perot tunable filter (FFP-TF) into the ring cavity. In addition, the output power, side-mode suppression ratio (SMSR), and the stabilities of power and wavelength of the laser also are investigated. (Copyright 2007 by Astro Ltd., Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA)

2007-01-01

435

Theoretical investigation of the behavior of an acoustic metamaterial with extreme Young's modulus  

British Library Electronic Table of Contents (United Kingdom)

A mechanical model with local resonators is proposed as an acoustic metamaterial that exhibits an unusual frequency-dependent effective stiffness. If treated as an equivalent elastic solid, its effective Young's modulus can become unbounded or vanishingly small at two respective frequencies. Moreover, in a certain frequency range, the effective Young's modulus would become negative, resulting in a band gap that coincides with this frequency range. The wave attenuation behavior and mechanism are studied through numerical simulations on the acoustic metamaterial model. The capability of the metamaterial to selectively block or filter unwanted waves is demonstrated by a numerical simulation example.

2011-01-01

436

The production of carrier-free lead-203  

International Nuclear Information System (INIS)

The chemical separation of carrier-free "2"0"3Pb following deuterium bombardment of a "2"0"3Tl target is described. Coprecipitation from strontium sulphate was used to separate the "2"0"3Pb from a solution of the thallium target in sulphuric acid. The SrSO_4 precipitate was filtered, washed and dissolved in hydrochloric acid, from which "2"0"3Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given. (U.K.).

437

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

438

Spinodal decomposition and giant magnetoresistance  

International Nuclear Information System (INIS)

We explore the relation of nanostructures with the appearance of giant magnetoresistance (GMR) in melt-spun CuCo ribbons. We find by energy-filtered transmission electron microscopy that the ribbons are composed of a periodic distribution of Co within the Cu, as in spinodal decomposition. The lamellar structure should thus be associated with GMR, as only a small percentage of the Co is present in the form of grains. This is counterintuitive, for no clear interfaces are present as required by standard models, and the period of the composition oscillation (43-52 nm) is an order of magnitude larger than the mean free paths for electrons. Upon annealing, a secondary spinodal decomposition appears following the same direction as the original.

2006-10-01

439

Selection of transverse modes in laser cavities containing waveguides and open parts  

International Nuclear Information System (INIS)

The transverse modes of a submillimetre laser cavity that contains waveguides and open parts were studied theoretically and experimentally with the purpose of finding methods for mode selection. Two methods based on the filtering of the Fourier spectra of the waveguide modes and the use of their interference were substantiated numerically and realised in experiment. Special attention was paid to the mode selection in tunable lasers. Scaling laws allowing one to use the obtained results in a wide range of the cavity parameters and wavelengths are presented. (laser applications and other topics in quantum electronics)

2001-04-30

440

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

441

Regeneration behavior of light-duty catalytic trap oxidizer systems  

Science.gov (United States)

A catalytic trap oxidizer based on a radial flow metal mesh filter was developed for use as an after treatment device on light-duty diesel vehicles. A complete system for assisted regeneration was devised to enable this unit to operate without blocking during all normal driving modes. The integration of the catalyzed trap and regeneration system with the vehicle to provide a practical system for the reduction of diesel particulate emissions is discussed. To date, many prototype catalytic trap and regeneration system installations have been completed on various test vehicles, both naturally aspirated and turbocharged. The operational conditions and test results from a selection of these studies are presented.

1984-01-01

442

Rapid Tools for Joint Inversion and Imaging. Final report  

Energy Technology Data Exchange (ETDEWEB)

The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.

2000-08-02

443

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

444

Radiation effect on optical, electrophysical and surface properties of GaAlAs heterostructures  

Energy Technology Data Exchange (ETDEWEB)

A study was made on the effect of 3.5 MeV electron irradiation on the properties of light-emissive structure based on GaAlAs. It is shown that a considerable decrease in the emitted light intensity as a result of electron irradiation not accompanied by changes in recombination- and electric properties of the mentioned structures. It is established by the electron-microscopy and Auger-spectroscopy meazurements that electron irradiation causes the occurrence of regions of free aluminium clusters on the external surface of the structure n-layer. The number and the sizes of the regions depend on the electron doze. It was assumed that the mentioned regions can play a role of attenuation filter for the light emitted by the structure.

1984-07-01

445

Provenance study of excavated pottery from Beirut using PIXE cluster analysis  

International Nuclear Information System (INIS)

The study of imported ceramics found in Beirut and suspected to belong to north Syrian products will provide key evidence for the roles in trade of the various postulated centers in northern Syria and northern Lebanon. It is proposed that a comprehensive range of likely north Syrian products imported to Beirut will be chemically analyzed by PIXE (proton induced X-ray emission) in order to characterize, compare and isolate the various regional production centers that supplied the city from the Persian to Byzantine periods. In this work, we were mainly focusing on the characterization of Amrit products, by using 3 MeV proton beam and Al funny filter, as X-ray absorber.

2006-08-01

446

Progress towards a 20 Ah/12 V zinc/air battery  

Energy Technology Data Exchange (ETDEWEB)

Electrode areas, for the bifunctional O{sub 2}-electrodes and the pasted Zn-electrodes, have been successfully scaled up from 25 cm{sup 2} up to 250 cm{sup 2}. A filter press type cell was used to measure the cycle life of larger electrodes (100 cm{sup 2}). Up to now, more than 100 charge-discharge cycles (900 hours) with these scaled up Zn/O{sub 2}-cells could be demonstrated. (author) 2 figs., 2 refs.

1997-06-01

447

Production of carrier-free lead-203  

Energy Technology Data Exchange (ETDEWEB)

The chemical separation of carrier-free /sup 203/Pb following deuterium bombardment of a /sup 203/Tl target is described. Coprecipitation from strontium sulphate was used to separate the /sup 203/Pb from a solution of the thallium target in sulphuric acid. The SrSO/sub 4/ precipitate was filtered, washed and dissolved in hydrochloric acid, from which /sup 203/Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given.

1982-07-01

448

Physics with Polarized Antiprotons  

Energy Technology Data Exchange (ETDEWEB)

Polarized antiprotons produced by spin filtering with an internal polarized gas target provide access to a wealth of single- and double-spin observables, thereby opening a window to physics uniquely accessible with the HESR at FAIR. This includes a first measurement of the transversity distribution of the valence quarks in the proton, and a first measurement of the moduli and the relative phase of the time-like electric and magnetic form factors G{sub E,M} of the proton. In polarized and unpolarized pp-bar elastic scattering open questions like the contribution from the odd charge-symmetry Landshoff-mechanism at large |t| and spin-effects in the extraction of the forward scattering amplitude at low |t| can be addressed.

2006-04-15

449

PLZT electrooptic shutters: applications  

Science.gov (United States)

Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.

1975-08-01

450

On the Suitability of Interleaved Switched Capacitor Converter as an Interface for Electric Vehicle Dual Energy Storage Systems  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the analysis and novel hybrid controller design for an interleaved 2-quadrant switched capacitor (SC) bidirectional DC/DC converter for a hybrid electric vehicle (HEV) dual energy storage system. The designed novel control strategy enables simpler dynamics compared to a standard buck converter with input filter, good regulation capability, low EMI, lower source current ripple, ease of control, and continuous input current waveform in both buck as well as boost modes of operation.

2010-09-15

451

Networks of companies and branches in Poland  

CERN Document Server

In this study we consider relations between companies in Poland taking into account common branches they belong to. It is clear that companies belonging to the same branch compete for similar customers, so the market induces correlations between them. On the other hand two branches can be related by companies acting in both of them. To remove weak, accidental links we shall use a concept of threshold filtering for weighted networks where a link weight corresponds to a number of existing connections (common companies or branches) between a pair of nodes.

2006-01-01

452

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

453

Modified-VSIMM algorithm with an application to the naval fire control technology  

British Library Electronic Table of Contents (United Kingdom)

A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.

2011-01-01

454

Interpreting Mammalian Evolution using Fugu Genome Comparisons  

Energy Technology Data Exchange (ETDEWEB)

Comparative sequence analysis of the human and the pufferfish Fugu rubripes (fugu) genomes has revealed several novel functional coding and noncoding regions in the human genome. In particular, the fugu genome has been extremely valuable for identifying transcriptional regulatory elements in human loci harboring unusually high levels of evolutionary conservation to rodent genomes. In such regions, the large evolutionary distance between human and fishes provides an additional filter through which functional noncoding elements can be detected with high efficiency.

2004-04-02

455

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

456

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

457

Device for increasing the decontamination factor in the treatment of radioactive waste water. Vorrichtung zur Erhoehung der Dekontaminationsfaktoren bei der Aufbereitung radioaktiver Abwaesser  

Energy Technology Data Exchange (ETDEWEB)

In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.

1982-06-09

458

Automatic interpretation of Schlumberger soundings  

Energy Technology Data Exchange (ETDEWEB)

The automatic interpretation of apparent resistivity curves from horizontally layered earth models is carried out by the curve-fitting method in three steps: (1) the observed VES data are interpolated at equidistant points of electrode separations on the logarithmic scale by using the cubic spline function, (2) the layer parameters which are resistivities and depths are predicted from the sampled apparent resistivity values by SALS system program and (3) the theoretical VES curves from the models are calculated by Ghosh's linear filter method using the Zhody's computer program. Two soundings taken over Takenoyu geothermal area were chosen to test the procedures of the automatic interpretation.

1980-09-01

459

Attenuated response to repeated daily ozone exposures in asthmatic subjects  

Energy Technology Data Exchange (ETDEWEB)

The development of attenuated response ({open_quotes}tolerance{close_quotes}) to daily ozone (O{sub 3}) exposures in the laboratory is well established in healthy adult volunteers. However, the capability of asthmatics to develop tolerance during multiday ozone exposures in unclear. We exposed 10 adult volunteers with mild asthma to 0.4 ppm O{sub 3} in filtered air for 3 h/d on 5 consecutive d. Two similar filtered-air exposures during the preceding week served as controls. Follow-up O{sub 3} exposures were performed 4 and 7 d after the most recent consecutive exposure. All exposures were performed in an environmental chamber at 31 {degrees}C and 35% relative humidity. The subjects performed moderate exercise (mean ventilation rate of 32 l/min) for 15 min of each half-hour. Responses were measured with spirometry and symptom evaluations before and after each exposure, and a bronchial reactivity test (methacholine challenge) was conducted after ...

1997-01-01

460

An optical fiber methane sensing system employing a two-step reference measuring method  

British Library Electronic Table of Contents (United Kingdom)

An optical fiber methane sensing system utilizing a super-luminescent diode (SLD) in the 1.33-mm band and a fiber Fabry-Perot tunable filter (FFP-TF) is developed. A two-step reference measuring method, which is based on differential absorption technique, is employed; a reference channel is introduced to eliminate the fluctuation of the illuminant spectrum, and the reference wavelength acquired by tuning the FFP-TF is introduced to eliminate the environmental influence. The two-step reference measuring method has improved the reliability and stability of the system. A minimum detectable methane concentration of 0.3% has been experimentally achieved.

2008-01-01

461

Ambient Air Radionuclide Concentrations at and near TA-50 from 2003 through the First Quarter of 2004  

Energy Technology Data Exchange (ETDEWEB)

The Meteorology and Air Quality (MAQ) group at Los Alamos National Laboratory maintains and operates a large network of environmental air samplers called AIRNET. Some of these samplers are located near Material Disposal Area C at TA-50, a low-level radioactive waste burial site in the semiarid environment of the Pajarito Plateau, near Los Alamos. AIRNET sampling media consist of a filter and silica gel. They are exchanged once every 2 weeks. Presented are 5 months of air sampling results for 5 stations operating in the vicinity of Material Disposal Area C.

2005-09-05

462

Accurate determination of detection efficiency and self-absorption factors in measuring radon daughter  

International Nuclear Information System (INIS)

The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.

463

A 40 GByte/s read-out system for GEM  

Energy Technology Data Exchange (ETDEWEB)

The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.

1994-04-01

464

Testing of CoTreat Inorganic Ion Exchange Media for the Removal of 60Co from Thorp Pond Water  

Energy Technology Data Exchange (ETDEWEB)

CoTreat, a new inorganic ion exchange media, has been studied in the laboratory to support its application as a pre- coat to existing Funda filters in THORP feed pond plant (Sellafield, UK). This is a novel way of application of CoTreat, which is usually utilized in fixed-bed ion exchange columns in a granular form. The results present the effect of operating conditions (CoTreat dose, pond water chemistry) on CoTreat performance for the removal of Co-57 tracer from simulated pond water. Major findings include the strong dependence of Co-57 decontamination factor (DF) on feed activity. At the 200 Bq/L feed level, the observed DF was 10-20 but rose to 1000 and above when the feed level was increased to 20000 Bq/L. Calcium present in the feed was found to decrease the DF at concentrations higher than 1 ppm. The laboratory studies showed significantly higher DF's than what has been observed in large-scale THORP tests. This discrepancy is likely to be due to ...

2003-02-25

465

Radiochemical Analyses of the Filter Cake, Granular Activated Carbon, and Treated Ground Water from the DTSC Stringfellow Superfund Site Pretreatment Plant  

Energy Technology Data Exchange (ETDEWEB)

The Department of Toxic Substance Control (DTSC) requested that Lawrence Livermore National Laboratory (LLNL) evaluate the treatment process currently employed at the Department's Stringfellow Superfund Site Pretreatment Plant (PTP) site to determine if wastes originating from the site were properly managed with regards to their radioactivity. In order to evaluate the current management strategy, LLNL suggested that DTSC characterize the effluents from the waste treatment system for radionuclide content. A sampling plan was developed; samples were collected and analyzed for radioactive constituents. Following is brief summary of those results and what implications for waste characterization may be made. (1) The sampling and analysis provides strong evidence that the radionuclides present are Naturally Occurring Radioactive Material (NORM). (2) The greatest source of radioactivity in the samples was naturally occurring uranium. The sample results indicate that the uranium ...

2005-09-16

466

Radiochemical Analyses of the Filter Cake, Granular Activated Carbon, and Treated Ground Water from the DTSC Stringfellow Superfund Site Pretreatment Plant  

International Nuclear Information System (INIS)

The Department of Toxic Substance Control (DTSC) requested that Lawrence Livermore National Laboratory (LLNL) evaluate the treatment process currently employed at the Department's Stringfellow Superfund Site Pretreatment Plant (PTP) site to determine if wastes originating from the site were properly managed with regards to their radioactivity. In order to evaluate the current management strategy, LLNL suggested that DTSC characterize the effluents from the waste treatment system for radionuclide content. A sampling plan was developed; samples were collected and analyzed for radioactive constituents. Following is brief summary of those results and what implications for waste characterization may be made. (1) The sampling and analysis provides strong evidence that the radionuclides present are Naturally Occurring Radioactive Material (NORM). (2) The greatest source of radioactivity in the samples was naturally occurring uranium. The sample results indicate that the uranium concentration ...

467

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and ...

2001-11-01

468

Guideline for Sampling and Analysis of Tar and Particles in Biomass Producer Gases. Version 3.3  

Energy Technology Data Exchange (ETDEWEB)

This Guideline provides a set of procedures for the measurement of organic contaminants and particles in producer gases from biomass gasifiers. The procedures are designed to cover different gasifier types (updraft or downdraft fixed bed or fluidised bed gasifiers), operating conditions (0 - 900C and 0.6-60 bars) and concentration ranges (1 mg/m{sub n}{sup 3} to 300 g/m{sub n}{sup 3}). The Guideline describes a modular sampling train, and a set of procedures, which include: planning and preparation of the sampling, sampling and post-sampling, analysis, calculations, error analysis and reporting. The modular sampling train consists of 4 modules. Module 1 is a preconditioning module for isokinetic sampling and gas cooling. Module 2 is a particle collection module including a heated filter. Module 3 is a tar collection module with a gas quench (optionally by circulating a liquid), impinger bottles and a backup adsorber. Module 4 is a volume-sampling module consisting ...

2002-07-01

469

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate from the field of Mathematical Morphology, focusing on region-based watershed segmentation. First biomedical images were ...

2006-03-01

470

An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy  

International Nuclear Information System (INIS)

Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition dose model is used to compute dose ...

1995-07-15

471

National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware  

Energy Technology Data Exchange (ETDEWEB)

When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...

2001-07-27

472

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and stations. Shelly et al. [2007] attempted ...

2009-12-01

473

Study of some Ayurvedic Indian medicinal plants for the essential trace elemental contents by instrumental neutron activation analysis and atomic absorption spectroscopy techniques  

Energy Technology Data Exchange (ETDEWEB)

Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)

2009-07-01

474

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

475

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

476

Reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of the reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mock-up of a liquid-metal fast breeder reactor and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mock-up, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies, to approximately 30 dollars subcritical.

1977-08-01

477

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

478

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

479

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

480

Peel-off case failure in thermal explosions observed by the deflagration cylinder test  

British Library Electronic Table of Contents (United Kingdom)

We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...

2009-01-01

481

Optimizing the emissions and diesel replacement on a dual fuel, two stroke bus engine  

Energy Technology Data Exchange (ETDEWEB)

Two natural gas/diesel dual fuel conversion systems for the Detroit Diesel 6V-71 transit bus engine were described. The basic concept of a dual fuel engine was to operate a diesel engine with both liquid fuel injection and a lean premixed gas mixture. The engine achieved high efficiency due to the high compression ratio typical of the diesel engine. Test results were obtained using three different calibrations on one engine. The objectives were to match existing engine performance with improved emissions and better overall fuel economics. Results showed that overall, engine conversion has both economic and emissions advantages over a straight diesel engine. However, the durability and in-use applicability of the system remains to be demonstrated with an in-bus demonstration project.. 3 tabs., 4 figs.

1995-12-31

482

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

483

Oil Spill Simulation and Validation in the Arabian (Persian) Gulf with Special Reference to the UAE Coast  

British Library Electronic Table of Contents (United Kingdom)

The use of numerical modeling in oil spill incidents is a well established technique that has proven to provide cost-effective and reasonable estimates of oil surface drift. Good predictability of such models depends highly on the quality of the input data of the incident and on the model calibration effort. This paper presents the results of simulating oil spillage trajectory in the Arabian (Persian) Gulf. The study employed a 3-D rectilinear hydrodynamic model combined with oil spill model. Typical representative environmental conditions of the Arabian Gulf were first setup into a hydrodynamic circulation model using data from various sources. The performance of the hydrodynamic model was then tested against measurements of tidal fluctuation and sea currents at selected locations. The sp...

2007-01-01

484

Microtiter plate assay for phosphate using a europium-tetracycline complex as a sensitive luminescent probe  

Energy Technology Data Exchange (ETDEWEB)

A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.

2006-01-12

485

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise ...

486

Innovative wind turbines. Circulation controlled vertical axis wind turbine. Progress report, March 1-December 31, 1976  

Science.gov (United States)

Theoretical and experimental research efforts in evaluating an innovative concept for vertical axis wind turbines (VAWT) are described. The concept is that of using straight blades composed of circulation controlled airfoil sections. The theoretical analysis has been developed to determine the unsteady lift and moment characteristics of multiple-blade cross-flow wind turbines. To determine the drag data needed as input to the theoretical analysis, an outdoor test model VAWT has been constructed; design details, instrumentation, and calibration results are reported. Initial testing is with fixed pitch blades having cross-sections of conventional symmetrical airfoils. Costs of building the test model are included, as well as estimates for blades constructed with composite materials. These costs are compared with those of other types of wind turbines.

1978-10-01

487

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

488

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

489

Improving functional esophageal surgery with a ?smart? bougie: endoflip  

British Library Electronic Table of Contents (United Kingdom)

Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...

2011-01-01

490

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

491

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

492

Fitness of equipment used for medical exposure to ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which gives rise to a medical ...

1992-05-01

493

Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation  

British Library Electronic Table of Contents (United Kingdom)

Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...

2011-01-01

494

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

495

Determination of macro, micro nutrient and trace element concentrations in Indian medicinal and vegetable leaves using instrumental neutron activation analysis  

Energy Technology Data Exchange (ETDEWEB)

Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.

1999-05-01

496

Analysis on Correlation between AE Parameters and Stress Intensity Factor using Principal Component Regression and Artificial Neural Network  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model

2001-02-15

497

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous ...

2009-07-23

498

A study on effects of parameters in the Lagrangian code based on F.E.M. through oblique dual-plates perforation phenomena  

International Nuclear Information System (INIS)

This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.

2004-11-03