WorldWideScience
1

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

2

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

3

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

4

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

5

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

6

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with ...

1984-11-08

7

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. ...

2008-08-01

8

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

9

Population exposure to external natural radiation background in the United States  

Energy Technology Data Exchange (ETDEWEB)

This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.

1981-04-01

10

Methodology used to compute maximum potential doses from ingestion of edible plants and wildlife found on the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential ...

1990-10-01

11

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

12

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

13

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

14

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

15

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

16

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

17

A marine compartment model for collective dose assessment of liquid radioactive effluents  

International Nuclear Information System (INIS)

A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).

1982-01-01

18

Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985  

Energy Technology Data Exchange (ETDEWEB)

Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.

1986-04-01

19

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from ...

2002-12-01

20

A comparison study for dose calculation in radiation therapy: pencil beam Kernel based vs. Monte Carlo simulation vs. measurements  

International Nuclear Information System (INIS)

Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment ...

2002-10-20

21

Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization  

CERN Document Server

Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator ...

2005-01-01

22

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as ...

1988-01-01

23

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

24

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of ...

2003-01-01

25

Mathematical child phantom for the calculation of dose to the organs at risk  

Energy Technology Data Exchange (ETDEWEB)

In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.

1988-05-01

26

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations ...

2007-08-01

27

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

28

Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres  

International Nuclear Information System (INIS)

Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.

1977-05-01

29

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average ...

2001-02-01

30

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated ...

2003-07-01

31

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

32

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. ...

1986-01-01

33

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the ...

1996-12-01

34

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

35

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses ...

1993-05-01

36

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses ...

1993-01-01

37

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by ...

1987-01-01

38

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

39

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the ...

1991-01-01

40

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with ...

1991-11-01

41

Calculated doses from inhaled transuranium radionuclides and potential risk equivalence to whole-body radiation  

International Nuclear Information System (INIS)

The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic ...

1975-11-17

42

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter ...

1988-10-01

43

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the ...

2011-01-01

44

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

45

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' ...

2009-10-15

46

Low dose effects - is the fear more dangerous than the radiation?  

Energy Technology Data Exchange (ETDEWEB)

The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value ...

1996-01-01

47

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous ...

2010-10-01

48

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. ...

2007-05-01

49

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

51

Estimated values of the genetic and somatic radiation exposure of the Bulgarian population in 1976  

International Nuclear Information System (INIS)

The genetically and leukemia-significant doses (GSD and LSD) were calculated from the average gonad and bone marrow doses caused by the most frequently applied radiopharmaceuticals in Bulgaria in 1976. Because of the lack of information about the age groups of the patients examined assumptions have been made which led to estimated values of 0.97 mrad for GSD and 2.0 mrad for LSD which must be considered as the upper limit of the real GSD and LSD. The influence of the different radiopharmaceuticals on the average radiation exposure of the population is discussed. (author).

1976-01-01

52

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

53

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...

2011-01-01

54

Alpha-particle dose distribution effects at the cellular level  

International Nuclear Information System (INIS)

Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.

1985-02-01

55

Bomb "1"4C and human radiation burden  

International Nuclear Information System (INIS)

Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially ...

56

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

57

Concepts in radiation protection  

International Nuclear Information System (INIS)

This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the ...

1996-01-01

58

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

59

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue  

International Nuclear Information System (INIS)

Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared ...

2003-10-01

60

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning ...

2001-03-01

61

Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools  

Energy Technology Data Exchange (ETDEWEB)

The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of ...

1987-06-15

62

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

63

The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)  

International Nuclear Information System (INIS)

As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.

64

Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki  

International Nuclear Information System (INIS)

For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the ...

1980-01-01

65

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation ...

2007-06-01

66

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment ...

67

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

68

Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2  

International Nuclear Information System (INIS)

The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 ...

1981-01-01

69

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose ...

1991-10-01

70

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

71

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...

2008-10-01

72

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

74

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is ...

75

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast ...

2004-07-01

76

A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-  

Energy Technology Data Exchange (ETDEWEB)

The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler ...

1995-07-01

77

Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs  

International Nuclear Information System (INIS)

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 ...

2008-09-07

78

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations  

International Nuclear Information System (INIS)

The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each ...

2006-09-01

79

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

80

Preparation of wood-polymer composites by using ionizing radiation  

International Nuclear Information System (INIS)

Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).

1982-05-01

81

Updated estimates of the proportion of childhood leukaemia incidence in Great Britain that may be caused by natural background ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of ...

2009-12-01

82

Pharmacokinetic and dosimetric characteristics of some thallium isotopes  

International Nuclear Information System (INIS)

Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the ...

83

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...

2007-01-01

84

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

85

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

87

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

International Nuclear Information System (INIS)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted ...

2009-10-01

88

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion ...

2006-09-15

89

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion ...

2006-09-01

90

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

91

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

92

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

93

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

94

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

95

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

96

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up ...

1983-01-01

97

Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation  

International Nuclear Information System (INIS)

Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by ...

1988-04-01

98

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

99

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

100

Dose consequences from a postulated criticality occurring in a low-level waste disposal facility  

Energy Technology Data Exchange (ETDEWEB)

Evaluations were done to determine conditions that could permit nuclear criticality with fissile uranium in low-level waste (LLW) facilities and to estimate potential radiation exposures to personnel if there were such an accident. Simultaneous hydrogeochemical and nuclear criticality studies were done (1) to identity realistic scenarios for uranium migration and concentration increase at LLW disposal facilities, (2) to model groundwater transport of uranium and subsequent concentration via sorption or precipitation, (3) to evaluate the potential for nuclear criticality resulting from potential increases in uranium concentration over disposal limits, and (4) to estimate potential radiation exposures to personnel resulting from criticality consequences. This paper presents the details of the radiation exposure calculations relying on the conditions as determined from the preceding studies detailed in a ...

1997-12-01

101

Monte Carlo-based investigation of effect of inhomogeneity in brachytherapy dose calculation - Part I  

International Nuclear Information System (INIS)

Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a ...

2009-04-01

102

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from ...

2002-12-01

103

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

International Nuclear Information System (INIS)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both ...

2005-03-01

104

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

105

Effective dose estimation in whole-body multislice CT in paediatric trauma patients  

Energy Technology Data Exchange (ETDEWEB)

The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a ...

2009-03-15

106

Ultraviolet radiation in Finland  

Energy Technology Data Exchange (ETDEWEB)

Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV ...

1996-12-31

107

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key ...

1983-01-01

108

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key ...

7871-01-01

109

Is uniform target dose possible in IMRT plans in the head and neck?  

International Nuclear Information System (INIS)

Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...

2002-04-01

110

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the ...

2010-07-07

111

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

112

PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT  

Energy Technology Data Exchange (ETDEWEB)

This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be essentially zero. In contrast, potential accidental releases from ...

2000-09-01

113

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

114

Radiological dose assessment for the decontaminated concrete removed from 183-H solar evaporation basins at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used ...

1997-01-01

115

Dosimetric evaluation and therapeutic response to iodine-131 labelled lipiodol in treatment of hepatocellular carcinomas; Evaluation dosimetrique et reponse therapeutique de la curietherapie metabolique des hepatocarcinomes par le lipiodol marque par l'iode 131  

Energy Technology Data Exchange (ETDEWEB)

Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution ...

2006-12-15

116

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

117

Radiotherapeutic methods for Ewing's sarcoma of the long tubular bones in children  

International Nuclear Information System (INIS)

Radiotherapeutic results of the Ewing sarcoma of the long tubular bones in 140 pediatric patients aged 3-16 are analyzed with the respect to different methods of irradiation. Three-field irradiation, the fields being located at 120 deg to one another with daily irradiation of all three fields at a focal dose of 2 Gy, was found superior in treatment of primary neoplasm. It is stressed that the disease termination mainly depends on the efficiency of primary neoplasm treatment, as the neoplasm reccurence generally is followed by metastases. Radiation load is calculated for maximal irradiation area of soft tissues in children.

118

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

119

Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)

2006-11-13

120

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay ...

121

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon ...

1999-09-20

122

The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations  

International Nuclear Information System (INIS)

Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The ...

2002-07-01

123

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

124

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

125

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

126

The optimum modification of energy spectra using FFT convolution/multigrid superposition algorithm on the focus radiation treatment system  

International Nuclear Information System (INIS)

In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The ...

2003-06-01

127

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

128

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

129

Induction of tumors by screening mammography  

International Nuclear Information System (INIS)

Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.

1983-01-01

130

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

131

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray ...

132

Cell death (apoptosis) in mouse intestine after continuous irradiation with gamma rays and with beta rays from tritiated water  

Energy Technology Data Exchange (ETDEWEB)

Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose ...

1989-04-01

133

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

Energy Technology Data Exchange (ETDEWEB)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT ...

2005-03-01

134

Deterministic calculations of radiation doses from brachytherapy seeds  

International Nuclear Information System (INIS)

Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third ...

2003-08-17

135

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

136

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

138

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

139

A proposal for prevention of acute radiation hazard and social panic regarding orphan sources in Japan  

International Nuclear Information System (INIS)

To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a categorization of orphan sources according to dose rates to deal with ...

2002-10-20

140

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

141

Radiation inactivation target size of rat adipocyte glucose transporter  

Energy Technology Data Exchange (ETDEWEB)

In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due ...

1987-05-01

142

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy ...

1993-10-13

143

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, ...

2003-06-01

144

Results of radon concentration measurements in some regions of Russia  

Energy Technology Data Exchange (ETDEWEB)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and ...

1996-01-01

145

Results of radon concentration measurements in some regions of Russia  

International Nuclear Information System (INIS)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the ...

146

A two-stage sequential linear programming approach to IMRT dose optimization  

UK PubMed Central (United Kingdom)

The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available

2010-02-07

147

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

148

Four cases of bowel perforation following radiation therapy for cervical cancer  

Energy Technology Data Exchange (ETDEWEB)

External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.

1984-10-01

149

Worker radiation doses in the United States at the dawn of the atomic era (1940--1960)  

Energy Technology Data Exchange (ETDEWEB)

Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.

1994-06-01

150

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for ...

1984-01-01

151

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

152

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the ...

2007-05-01

153

Significance of the results from probabilistic safety assessment at level 2 for off-site consequences  

Energy Technology Data Exchange (ETDEWEB)

The procedure was developed to enable STUK (Radiation and Nuclear Safety Authority) to make simplified estimates on off-site consequences based on the existing results of the PSA level 2 calculations done by e.g. power utilities. Method is based on dose calculated from each nuclide group of reactor activity inventory when the same release fraction for each group is assumed. This means that a specific new result from PSA level 2 can be categorised to find out a representative PSA level 3 result for this case. In addition a user interface including the procedure was prepared. Secondly some new insights about consequences based on the releases from PSA level 2 is expected to give better understanding of risks at prevailing increased reactor power levels. In this case only some early health effects and long-term doses were estimated without full-scope PSA level 3 approach. (orig.)

2000-07-01

154

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the ...

2007-04-01

155

Range and modulation dependencies for proton beam dose per monitor unit calculations  

UK PubMed Central (United Kingdom)

Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available

2009-02-01

156

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction ...

1997-08-01

157

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing ...

2006-04-01

158

Improvement of top shield analysis technology for CANDU 6 reactor  

Energy Technology Data Exchange (ETDEWEB)

As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex ...

1996-07-01

159

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant ...

1984-06-01

160

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

161

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

162

Luminescence geochronology and evaluation of the environmental dose rate for the Neanderthal deposits at Vindija Cave (Northern Croatia)  

International Nuclear Information System (INIS)

Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our ...

2008-04-13

163

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal ...

2008-11-19

164

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide ...

165

27: Development of a convolution/superposition method for photon beams  

International Nuclear Information System (INIS)

The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.

166

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the ...

2006-07-01

167

Fluence-convolution broad-beam (FCBB) dose calculation  

International Nuclear Information System (INIS)

IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in ...

2010-12-07

168

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

169

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high ...

1976-01-01

170

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like ...

2003-08-17

171

Development of an irradiation system for a small size continuous run multipurpose gamma irradiator  

International Nuclear Information System (INIS)

The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 ...

172

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

173

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

174

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those ...

2003-07-21

175

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

176

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace the focal and ...

2005-09-07

177

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the ...

1992-07-12

178

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

179

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

180

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

181

Decree of the Ministry of Health about conditions of irradiation of food, permissible additional substances or other food components, which can be subjected to ionizing radiation action, their specification, maximum irradiation doses as well as about requirements for marking and introducing into turnover  

International Nuclear Information System (INIS)

The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.

2003-03-04

182

Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator  

International Nuclear Information System (INIS)

The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance ...

2002-09-21

183

Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications  

International Nuclear Information System (INIS)

A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.

1996-07-15

184

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse ...

185

The natural background approach to setting radiation standards  

International Nuclear Information System (INIS)

The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent ...

1979-03-09

186

Long-term effects of inhaled uranyl nitrate in rats  

International Nuclear Information System (INIS)

Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.

1977-05-01

187

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

1981-06-01

188

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

189

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example ...

1980-10-31

190

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

191

Analysis of photon beam exit dose using photon point kernels  

International Nuclear Information System (INIS)

The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).

192

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

193

Effect of radiation dose on the properties of natural rubber nanocomposite  

Energy Technology Data Exchange (ETDEWEB)

Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the ...

2010-12-15

194

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also ...

2004-12-01

195

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

197

Radiation oxidation of phenol in petrochemical waste water. II  

International Nuclear Information System (INIS)

The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and ...

1981-01-01

198

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

200

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. ...

1992-11-01

201

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

203

Adaptive Management of Liver Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available

2010-04-01

204

Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV  

Energy Technology Data Exchange (ETDEWEB)

Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).

1989-01-01

205

Optimizing an analytical dose calculation algorithm for fast 2D calculations  

International Nuclear Information System (INIS)

Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly ...

206

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

207

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

208

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

209

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

210

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...

1982-06-25

211

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...

2008-05-01

212

Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT  

International Nuclear Information System (INIS)

With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix ...

2007-08-01

213

Risk assessment for radiation protection purposes  

International Nuclear Information System (INIS)

In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is ...

1980-01-01

214

Health risks arising from ionizing radiation and chemical pollutants  

International Nuclear Information System (INIS)

In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the ...

1979-10-03

215

Continuous intensity map optimization (CIMO): A novel approach to leaf sequencing in step and shoot IMRT  

International Nuclear Information System (INIS)

A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle"3 treatment planning system. The CIMO algorithm was applied, and the optimized aperture shapes and weights were ...

2006-04-01

216

Application of low dose radiation for preservation of sea foods  

International Nuclear Information System (INIS)

Treatment of food with low doses of gamma radiation has been recognized to have two main advantages. These consist of: (1) improvement of food safety by elimination of pathogens and (2) reduction of microbial spoilage and extension of shelf life of perishable items by reducing the number of viable spoilage organisms. Studies during the last few decades have conclusively proved the beneficial effects of radiation with respect to fishery products. The three potential areas of application to fish products include: (i) radurization for shelf life extension (ii) radicidation to eliminate food borne pathogens in the products and (iii) radiation treatment to dried products to control insects.

1994-03-01

217

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

218

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL ...

1991-06-01

219

AIDE: internal dosimetry software.  

Science.gov (United States)

AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and ...

2008-03-12

220

Postremediation dose assessment for the former Alba Craft Laboratory site, Oxford, Ohio  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates were calculated for the former Alba Craft Laboratory site in Oxford, Ohio, which was involved in machining of uranium metal in the 1950s for the U.S. atomic energy program. The site is not currently being used. The residual radioactive material guidelines (RESRAD) computer code, which implements the methodology described in the US Department of Energy`s (DOE`s) manual for establishing residual radioactive material guidelines, was sued in this evaluation. Three potential land use scenarios were considered for the former Alba Craft site; the scenarios vary with regard to the type of site use, time spent at the site by the exposed individual, and sources of food consumed. Scenario A (a possible land use scenario) assumed industrial use of the site; Scenario B (a likely future land use scenario) assumed residential use of the site; and Scenario C (a possible but unlikely land use scenario) ...

1996-04-01

221

Evaluation of Beta-Absorbed Fractions in a Mouse Model for 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177Lu Radionuclides  

Energy Technology Data Exchange (ETDEWEB)

Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% ...

2005-08-01

222

Depuration of shellfish by irradiation: Final technical report, October 1, 1987--March 31, 1989  

International Nuclear Information System (INIS)

Studies by the University of Lowell Radiation Laboratory and the US National Marine Fisheries Service N.E. Laboratory in Gloucester, MA on softshelled clams (Mya arenaria) demonstrated the effectiveness of low to medium doses of Cobalt 60 source gamma irradiation in the inactivation of Escherichia coli, Salmonella typhimurium, Staphylococcus aureus and Streptococcus faecalis. Post-irradiation survival and organoleptic studies when extended to hardshelled clams (Mercinaria mercenaria) and American oysters (Crassostrea virginica) showed no significant decline in consumer qualities or 6 day post irradiation survival in oysters at doses of up to 3.0 kGy. The capacities of the American oyster to sustain relatively high doses of gamma irradiation were demonstrated by 6 day post-exposure survivorship values of greater than 90% for samples receiving 3.0, 5.0 and 7.0 kGy. Initial studies of inactivation of Polio ...

223

Medical irradiation and the use of the 'effective dose equivalent' concept  

International Nuclear Information System (INIS)

By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also ...

1980-03-01

224

Experts' discussion on the possibility of quantification of the radiation hazard  

International Nuclear Information System (INIS)

Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).

1978-01-01

225

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

226

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use ...

2005-02-21

227

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

228

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly ...

2005-10-01

229

Inhalation Exposure Input Parameters for the Biosphere Model  

Energy Technology Data Exchange (ETDEWEB)

This analysis is one of 10 reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN) biosphere model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. Inhalation Exposure Input Parameters for the Biosphere Model is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the ...

2004-09-10

230

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural ...

1990-05-01

231

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: Proposal for an adapted formalism  

International Nuclear Information System (INIS)

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.

2001-04-01

232

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can ...

233

Effect of Nordic diets on ECOSYS model predictions of ingestion doses  

British Library Electronic Table of Contents (United Kingdom)

The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...

2010-01-01

234

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be ...

2001-03-01

235

Comparing dose calculation algorithms for an orthovoltage beam in a bone phantom  

International Nuclear Information System (INIS)

The aim of this work was to compare dose calculation algorithm results at orthovoltage energies for a phantom composed of a bone slab in water. The calculation methods investigated were: no correction, ETAR, Batho, convolution/superposition and Monte Carlo. All algorithms calculated depth dose curves in a water phantom within 4% of experiment. However in the bone phantom, differences of over 40% between the No Correction / ETAR / Batho / Convolution and Monte Carlo results in the 1 cm thick bone slab were observed. These differences are predominantly because the algorithms do not account for the differing atomic number of the bone compared to water The increased dose to bone and the tissue adjacent to the bone interface should be considered when treating with orthovoltage photons. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

1998-09-01

236

Report of National Cancer Institute symposium: comparison of mechanisms of carcinogenesis by radiation and chemical agents. I. Common molecular mechanisms  

Science.gov (United States)

Some aspects of molecular mechanisms common to radiation and chemical carcinogenesis are discussed, particularly the DNA damage done by these agents. Emphasis is placed on epidemiological considerations and on dose-response models used in risk assessment to extrapolate from experimental data obtained at high doses to the effects from long-term, low-level exposures. 3 references, 6 figures. (ACR)

1984-01-01

237

Induced mutation in Lupinus mutabilis sweet in Peru  

International Nuclear Information System (INIS)

Mutagenesis of Lupinus mutabilis was started at the UNA LM (Peru) to obtain mutants with low alkaloid content and early germination. Varieties SCG 25 and Lib 020 were irradiated with gamma radiation. The optimum dose for the SCG 25 variety was 15 Krad and for Lib 020 15 to 20 Krad. The relation between the plant height and radiation dose fits the quadratic polynomial model.

1984-04-01

238

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to ...

239

Basic mechanisms of radiation effects in the natural space radiation environment  

Energy Technology Data Exchange (ETDEWEB)

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

1994-06-01

240

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

241

Mechanism of radiation induced carcinogenesis: does a threshold exist?  

International Nuclear Information System (INIS)

Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).

1996-10-23

242

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

243

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made ...

2005-11-23

244

Radiation decontamination of dry food ingredients and processing aids  

International Nuclear Information System (INIS)

Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial ...

245

Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium  

International Nuclear Information System (INIS)

Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)

2007-09-03

246

Mutual recombination and clusterization effect of the vacancy and interstitial barriers on radiation hardening materials  

British Library Electronic Table of Contents (United Kingdom)

There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.

2009-01-01

247

The importance and unique aspects of radiation protection in medicine  

British Library Electronic Table of Contents (United Kingdom)

Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...

2010-01-01

248

Radiation: how safe is safe?  

International Nuclear Information System (INIS)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-01

249

Radiation: how safe is safe  

Energy Technology Data Exchange (ETDEWEB)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic ...

1993-05-15

250

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

251

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

252

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

253

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

254

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points ...

2009-07-01

255

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and ...

256

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose ...

2011-02-01

257

Radiation-stimulated diffusion of aerosols  

Energy Technology Data Exchange (ETDEWEB)

The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.

1984-04-01

258

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

259

RADSOLVER: a computer program for calculating spectrally-dependent radiative heat transfer in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.

1981-09-01

260

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two ...

1996-12-31

261

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

262

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

263

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...

2006-04-01

264

Practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc

2004-05-01

265

Difference between delayed radiation-necroses of the cerebral hemispheres and midline: its bearing in radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.

1980-08-01

266

Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics  

International Nuclear Information System (INIS)

Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)

2008-08-01

267

On the effects of low radiation doses  

International Nuclear Information System (INIS)

The prevailing hypothesis of linear extrapolation from high to low radiation doses without any threshold level is being questioned more and more strongly for radiobiological and epidemiological reasons and, consequently, also on socio-economic and ethical grounds. A cost-benefit analysis based on scientific facts and made plausible to the general public, concentrating on a comparison with demonstrable natural and manmade risks, most probably would result not only in the permissible limits being raised by a considerable margin, but also in billions of costs saved, and in greater acceptance of all peaceful uses of radiation, nuclear power included. (orig.)

1998-10-01

268

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

269

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

270

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

271

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

272

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

273

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...

1989-08-15

274

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection ...

1995-07-01

275

Ingestion dose for molybdenum: dependence on the administration form; Ingestionsdosis fuer Molybdaen: Abhaengigkeit von der verabreichten Form  

Energy Technology Data Exchange (ETDEWEB)

Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer ...

1998-12-31

276

Retrospective Monte Carlo dose calculations with limited beam weight information  

International Nuclear Information System (INIS)

An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient ...

2007-01-01

277

Methodology for calculating guideline concentrations for safety shot sites  

Energy Technology Data Exchange (ETDEWEB)

Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites ...

1997-06-01

278

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also ...

1994-02-01

279

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

280

Environmental Radiation Effects: A Need to Question Old Paradigms  

Energy Technology Data Exchange (ETDEWEB)

A historical perspective is given of the current paradigm that does not explicitly protect the environment from radiation, but instead, relies on the concept that if dose limits are set to protect humans then the environment is automatically protected as well. We summarize recent international questioning of this paradigm and briefly present three different frameworks for protecting biota that are being considered by the U.S. DOE, the Canadian government and the International Commission on Radiological Protection. We emphasize that an enhanced collaboration is required between what has traditionally been separated disciplines of radiation biology and radiation ecology if we are going to properly address the current environmental radiation problems. We then summarize results generated from an EMSP grant that allowed us to develop a Low Dose Irradiation Facility ...

2003-03-27

281

Effect of radiation on certain animal viruses in liquid swine manure  

International Nuclear Information System (INIS)

The virucidal effect of _6_0Co gamma radiation was studied in cell culture medium and in liquid swine manure involving the most important porcine viruses that can be spread by liquid manure. The radiation doses (20 kGy and 30 kGy) were determined in preliminary experiments employing a porcine enterovirus from the serogroup 1 (Teschen group). In the main experiment, the following viruses were employed: swine vesicular disease (SVD) virus, type C foot-and-mouth disease (FMD) virus, a field strain of Aujeszky's disease (AD) virus, transmissible gastroenteritis (TGE) virus, as well as bovine viral diarrhoea (BVD) virus. The latter strain served as a model for hog cholera virus. The results of the experiments indicate that safe disinfection of the virus infected liquid swine manure by ionizing radiation requires a radiation dose of 30 kGy. (author).

1983-01-01

282

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal ...

2008-11-19

283

Chain radiation-chemical cross-linking of polyethylene under high pressures. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Regularities in the radiation cross-linking of low-density polyethylene under various conditions of ..gamma..-irradiation were studied. It is shown that at the 0.5 GPa pressure and 450 K the gel formation is initiated at doses of about 1 kGy, i.e. at doses 10 times as low as compared to normal conditions. Abnormally high rate of radiation cross-linking at high temperature and high pressure is an evidence of changes in the mechanism of polyethylene, radiation cross-linking, i.e. of the process transition from nonchain to chain conditions. Decrease in the potential barriers of macroradical reactions with macromolecules is the most probable reason of change in the polymer cross-linking nature.

1984-01-01

284

C-14 release and transport from a nuclear waste repository in an unsaturated medium  

Energy Technology Data Exchange (ETDEWEB)

The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...

1990-06-01

285

Calculating electron dose using a convolution/superposition method. 120  

International Nuclear Information System (INIS)

The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on ...

286

AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source  

International Nuclear Information System (INIS)

We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be ...

2004-04-01

287

Radiation hazards from medical applications  

International Nuclear Information System (INIS)

An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).

1980-05-31

288

Health hazards to children due to the Chernobyl accident?  

International Nuclear Information System (INIS)

The article tries to assess the radiation effects as objectively as possible. In conclusion, some steps that should be taken in future are listed, as e.g.: continuous monitoring of the radioactivity levels in air and soil, and recording of data for complete information. Further, investigation and assessment of radiation exposure of children, especially in regions most heavily affected; radioactivity monitoring of the food and milk given to children, and scientific research into the problem by pediatrists, and determination of maximum acceptable radiation doses. (orig./HSCH).

289

Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability  

Energy Technology Data Exchange (ETDEWEB)

Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation ...

2005-06-01

290

Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)  

Energy Technology Data Exchange (ETDEWEB)

The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities ...

2006-01-17

291

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the ...

2010-06-15

292

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance ...

2010-06-01

293

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at ...

1976-01-01

294

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have ...

2006-01-01

295

Influence of dose calculation algorithms on isotoxic dose-escalation of non-small cell lung cancer radiotherapy  

International Nuclear Information System (INIS)

Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same ...

2010-12-01

296

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...

297

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

298

Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone  

International Nuclear Information System (INIS)

Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.

299

Prediction of monitoring data for 239Pu accidentally injected via wound site based on the proposed NCRP wound model.  

Science.gov (United States)

In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The committed ...

2007-06-07

300

Mechanical Engineering and Design of the LHC Phase II Collimators  

CERN Document Server

Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time ...

2010-01-01

301

Implementation of the NCRP wound model for interpretation of bioassay data for intake of radionuclides through contaminated wounds.  

Science.gov (United States)

Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and daily urinary or ...

2009-05-01

302

Environmental pollutant isotope measurements and natural radioactivity assessment for North Tushki area, south western desert, Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is ...

2002-09-01

303

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high ...

1981-01-01

304

Principles of protection: a formal approach for evaluating dose distributions  

International Nuclear Information System (INIS)

One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.

2006-03-01

305

Preparation of wood-polymer composites using radiation  

International Nuclear Information System (INIS)

Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical ...

1976-11-25

306

Effect of some chemicals on the radiation-induced lipid peroxidation  

International Nuclear Information System (INIS)

The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).

307

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs ...

2009-01-01

308

The elevation of blood levels of zinc protoporphyrin in mice following whole body irradiation  

Energy Technology Data Exchange (ETDEWEB)

Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system ...

1984-05-01

309

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

310

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

311

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

312

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

313

Detection of irradiated chicken by ESR spectroscopy of bone  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).

1995-10-01

314

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut ...

1984-10-01

315

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut ...

1984-10-01

316

Cooperative spontaneous emission from two different atoms  

International Nuclear Information System (INIS)

The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).

1986-01-01

317

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...

2001-07-01

318

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during ...

319

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was ...

1983-12-01

320

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized ...

2009-08-01

321

Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects  

Energy Technology Data Exchange (ETDEWEB)

Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate ...

1996-12-31

322

Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler  

Energy Technology Data Exchange (ETDEWEB)

A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.

1986-09-01

323

Assessing radiologic risk for population due to human activities  

International Nuclear Information System (INIS)

The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well ...

2002-09-06

324

The calculation of derived release limit on Wolsung NPPs based on reduced public dose limit  

Energy Technology Data Exchange (ETDEWEB)

According to enactment of reduced dose limit based on ICRP-60, the calculation of Derived Release Limits(DRL) on Wolsung NPPs was carried out. There are two methods of determination on DRL; that is MPC(Maximum Permissible Concentration) method and system analysis method. In order to use the system analysis method, lots of environmental data are necessary and complicated exposure pathway are considered. So we intend to apply MPC method that is sort of simple. In addition the calculated results were compared with derived release limit on Canadian nuclear power plant.

2000-10-01

325

Monte Carlo Uncertainty Analyses of Pulsed Activation in the National Ignition Facility Gunite Shielding  

International Nuclear Information System (INIS)

The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.

2003-05-01

326

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

327

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

328

Cooperative Effects on Transient Spectral Hole Burning  

Science.gov (United States)

... of Dist SpeA tI/ __LLL5' Page 5. 3 the coherent effects on the spontaneous radiation, we calculate the pump- field-induced ...

1992-06-01

329

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three ...

1981-01-01

330

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...

2006-07-01

331

Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases  

International Nuclear Information System (INIS)

The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm ...

2007-07-07

332

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

333

Possible preparation of wood-plastic composites based on unsaturated polyester resins and styrene by radiation and chemical methods in combination  

Energy Technology Data Exchange (ETDEWEB)

Using the radiation chemical method it is possible to prepare wood-plastic composites using doses of 1 to 2.5 kGy. The impregnation mixture in the wood gelatinates and subsequent curing using chemical initiators takes place without outflow of the mixture from the wood and without formation of incrustations. The basic components of the impregnation mixtures used were unsaturated polyester resins; styrene or methyl methacrylate was used as the thinner. The proven initiator of polymerization was 2,2'-azobisisobutyronitrile. The technology is described of wood impregnation and radiation or chemical curing. The effects were monitored of viscosity, temperature, radiation dose and the concentrations of the individual components of the impregnation mixtures and initiators of polymerization on the process of the preparation of wood-plastic composites.

1983-06-01

334

Effect of ionizing radiation on the properties of PLA packaging materials  

International Nuclear Information System (INIS)

Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)

335

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived ...

1988-09-01

336

Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983  

International Nuclear Information System (INIS)

Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be ...

1988-01-01

337

Salmonella radicidation of poultry carcasses  

International Nuclear Information System (INIS)

This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were ...

2005-09-22

338

Radioactivity of Tobacco Leaves and Radiation Dose Induced from Smoking  

UK PubMed Central (United Kingdom)

The radioactivity in tobacco leaves collected from 15 different regions of Greece and before cigarette production was studied in order to find out any association between the root uptake of radionuclides...Full Text Available

2009-02-01

339

Radiation grafting processes and properties of leathers modified with butyl acrylate  

International Nuclear Information System (INIS)

Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished by traditional ...

1982-01-01

340

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

341

Emergency Reference Levels: Criteria for Limiting Doses to the Public in the Event of Accidental Exposure to Radiation.  

Science.gov (United States)

Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...

1981-01-01

342

Elimination of organics chemicals in aqueous solutions by gamma radiation processing  

International Nuclear Information System (INIS)

The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, ...

1992-08-16

343

Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available

344

An Association between the Radiation-Induced Arrest of G2-Phase Cells and Low-Dose Hyper-Radiosensitivity: A Plausible ...  

Science.gov (United States)

... Regine, Nader Hanna, Michael C. Garofalo, Austin Doyle, Susanne Arnold, Ritesh Kataria, Jacqueline Sims, Ming Tan, Mohammed Mohiuddin. ( ... ...

345

A computer program for rapid calculation of internal committed effective dose through inhalation and ingestion pathways under radiological emergency  

International Nuclear Information System (INIS)

Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)

2008-08-01

346

Radiation induced micrencephaly in guinea pigs  

International Nuclear Information System (INIS)

A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays ...

2006-04-20

347

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability ...

348

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin ...

2010-07-01

349

Estimation of dose in irradiated chicken bone by ESR method  

Energy Technology Data Exchange (ETDEWEB)

The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones ...

1998-03-01

350

Study of total ionizing dose radiation effects on nitride/oxide stack gate MOS capacitor  

International Nuclear Information System (INIS)

The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)

2008-07-01

351

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

352

IRSL characteristics of NaCl and KCl relative to dosimeter  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is to determine and compare the dosimetric properties of NaCl and KCl samples using infrared-stimulated luminescence (IRSL) technique. For a material to be used as dosimeter, both the IRSL temperature dependence and the radiation dose response have critical importance. In this work the IRSL characteristics from NaCl and KCl samples were experimentally investigated as a function of temperature and laboratory radiation doses. Dosimetric properties of NaCl and KCl samples were found significantly different. The IRSL signals displayed by NaCl were found to be more stable, reliable and agreeable than those of KCl.

2007-01-15

353

Comparison of Atmospheric Dispersion Models Between PHWR and PWR  

International Nuclear Information System (INIS)

The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences

2010-10-01

354

Calculated fluence spectra at neutron therapy facilities  

International Nuclear Information System (INIS)

The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).

1995-11-13

355

Radiation hardening of final optics for an ICF reactor  

International Nuclear Information System (INIS)

Radiation damage of the final optical components in an Inertial Confinement Fusion (ICF) reactor is a crucial issue for development of a laser-fusion reactor. To some extent, this problem will be encountered in the National Ignition Facility (NIF), but there, the integrated radiation dose will be considerably less than that encountered in a future reactor. This extremely harsh radiation environment necessitates shielding the ICF optics from direct neutron and x-ray bombardment. Several approaches have been suggested, such as the use of grazing incidence metal mirrors or fused silica wedge deflectors. While metal mirrors can withstand a larger radiation dose, their focusing qualities pose problems. Therefore wedge deflectors, originally suggested by Lawrence Livermore National Laboratory (LLNL) staff, represent a promising alternative. ...

1995-04-24

356

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants ...

357

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...

2008-05-01

358

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

359

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single ...

2007-09-15

360

Non-Linear Dose-Response Relationships in Biology, Toxicology and Medicine - An International Conference  

Energy Technology Data Exchange (ETDEWEB)

Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.

2002-05-28

361

Commentary  

International Nuclear Information System (INIS)

1. It is not possible to give a threshold value for the dose - nor for genetic neither for somatic late effects. 2. The linear dose-effect exprapolation is not conservative in the sense of 'fying on the safe side'. 3. There has been found no relative reduction of the effects at chronic radiation exposure in man. 4 The numbers given by authorities and utilities for damage rates per rem received, that are called upper limits, are by far too low. (orig./HP).

1980-02-01

362

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

363

Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation  

International Nuclear Information System (INIS)

Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).

364

Radiation factors specifying safety in reactor compartments handling in the process of decommissioning nuclear-powered submarines  

International Nuclear Information System (INIS)

The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity ...

1996-03-10

365

Effect of gamma radiation on the survival of fungal and actinomycetal florae contaminating medicinal plants  

Energy Technology Data Exchange (ETDEWEB)

This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total ...

1997-01-01

366

Monte Carlo treatment planning for photon and electron beams  

British Library Electronic Table of Contents (United Kingdom)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...

2007-01-01

367

Collapsed cone and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases  

International Nuclear Information System (INIS)

The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use ...

2007-06-01

368

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo ...

2007-04-01

369

Isochron measurements of naturally irradiated K-feldspar grains  

International Nuclear Information System (INIS)

The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their ...

2007-09-01

370

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped ...

2006-02-07

371

Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada  

Energy Technology Data Exchange (ETDEWEB)

Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and ...

1994-06-01

372

Assessment of the impact of the greenhouse gas emission and sink scenarios in Finland on radiative forcing and greenhouse effect  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...

1996-12-31

373

Calculation method for microwave pyramidal horn radiators with curvilinear generatrix  

British Library Electronic Table of Contents (United Kingdom)

Calculation method for pyramidal horn radiators (PHR) with curvilinear generatrix has been developed on the basis of the theory of waveguide tapers. This method makes it possible to reduce the value of spurious reflection coefficients and transformation of the principal wave into waves of higher order modes by forming generatrixes of walls with specific curvilinearity.

2008-01-01

374

Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ ...

2003-01-01

375

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss ...

2008-01-01

376

The influence of electron-beam irradiation on some mechanical properties of commercial multilayer flexible packaging materials  

International Nuclear Information System (INIS)

The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.

2008-09-21

377

Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE  

International Nuclear Information System (INIS)

A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.

1990-07-16

378

Nuclei with protrusions - tailed nuclei - and radiation cytogenetic markers in X-irradiated lymphocytes in vitro  

International Nuclear Information System (INIS)

The results of an investigation into tailed nuclei (TN) and features of dose dependence on frequency of the binuclear cells with TN in human lymphocyte cultures by cytogenetic block method upon X-ray radiation dose are presented. The frequencies of metaphases with dicentric and ring chromosomes are investigated concurrent with TN formed upon completion of first postradiation mitosis. Frequency of the appearance of binuclear cells with nuclei having outgrowth into the cytoplasmic space and arises after first mitosis in human lymphocyte culture is linear-square dependent on the X-irradiation at doses from 0.0 to 4.0 Gy. Positive correlation between frequency of cells with tailed nuclei and frequency of metaphases of first mitosis having dicentric and rings was established. Apparently, formation such TN is connected with dicentric and rings

379

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Science.gov (United States)

Recently the author showed that the widely used simulation code TDA3D, even though a single frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, the author applies this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, he shows that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is substracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1998-08-01

380

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Energy Technology Data Exchange (ETDEWEB)

Recently, we showed (Yu, Phys. Rev. E 58 (1998) 4991) that the widely used simulation code TDA3D, even though a single-frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, we apply this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, we show that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is subtracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1999-06-01

381

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood ...

2003-01-01

382

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the ...

1999-02-01

383

Unusual resistance to ionizing radiation of the viruses of kuru, Creutzfeldt-Jakob disease, and scrapie.  

UK PubMed Central (United Kingdom)

The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available

1978-12-01

384

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

385

Serious radiation accidents and the radiological impact on agriculture  

International Nuclear Information System (INIS)

The consumption of food products obtained in areas subjected to radioactive contamination as a consequence of a radiation accident appears to be the most significant source of irradiation for the population. At the same time, this route can be regulated very effectively. The regularities of contamination of agricultural production, peculiar features of internal dose formation in the population and the effectiveness of countermeasures in agriculture have been analysed using the experience of two major accidents in the former USSR - in the South Urals (Kyshtym accident) in 1957, and at the Chernobyl NPP in 1986. (Author).

386

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

Mechanical properties of vanadium, irradiated with fast neutrons up to 8.6x10"-"4 dpa depending on postirradiation annealing temperature, are studied. It is shown that radiation-annealing hardening (RAH) is observed at 300 deg C, which agrees with earlier performed studies. It is first stated that RAH is accompanied by plasticity decrease. Phenomenological model permitting to explain RAH dependence on irradiation temperature and dose and also on content of chemically active alloying impurities is suggested.

387

Radiation hardening of a high voltage IC technology (BCDMOS)  

International Nuclear Information System (INIS)

A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.

1990-07-16

388

Biological effects and health risks following to the exposition to ionizing radiation  

International Nuclear Information System (INIS)

Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.

1976-01-01

389

Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur  

International Nuclear Information System (INIS)

Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting

2010-02-03

390

Advanced composite materials made by radiation processing  

Energy Technology Data Exchange (ETDEWEB)

An industrial EB processing line is started to produce cement-bound /CB/ chipboard with radiation cured acrylic coating. The basic features of this line are presented here. The main technological parameters of coating such as: effect of oligomer- and monomer reactivity, monomer functionality, dose-rate and inerting atmosphere on the progress of curing have been discussed. The EB processed CB board is an advanced composite material for the modern lightweight architecture.

1988-01-01

391

Radioactivity of people in Finland after the Chernobyl accident in 1986  

International Nuclear Information System (INIS)

After the reactor accident at Chernobyl on April 26, 1986 radioactive fallout was carried by air currents to most parts of Europe. The radioactive air currents reached Finland on April 27. Immediately after the arrival of such air in Finland, contamination of people by radioactive nuclides began via inhalation of this air. The ingestion route become important later, when radionuclides were transported via different foodchains to man. To determine the level of radionuclides in the body and to estimate the internal radiation doses caused by the Chernobyl accident, whole-body counting measurements were performed. The results of whole-body counting of six different groups of Finnish people measured during 1986 after the accident at Chernobyl are reported. Three were reference groups measured routinely once or twice annually, two groups were comprised of workers at nuclear power stations and one group consisted of 262 persons not belonging to any ...

2004-02-01

392

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

393

Solar flux distribution in cavity receivers with parabolic dish collector  

Energy Technology Data Exchange (ETDEWEB)

Thermal absorption with its combined thermal and mechanical loads in a solar receiver does depend significantly on the distribution of incident solar radiation. For a cavity receiver with paraboloid collectar a method is derived which enables the calculation of solar radiation distribution on the areas inside the receiver. The theoretical bases are presented first, and a subsequent example shows the influence of the most important geometric parameters on the distribution of solar radiation.

1982-01-01

394

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency ...

2010-04-15

395

The effect of irradiation on packaging materials  

International Nuclear Information System (INIS)

Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for ...

396

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose ...

397

Multicellular level dosimetry and low dose rate effects  

International Nuclear Information System (INIS)

Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.

1989-09-21

398

A dose computation algorithm used in MLC conformal treatment  

International Nuclear Information System (INIS)

A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)

2007-12-01

399

Phase I Study of Conformal Radiotherapy and Concurrent Full-Dose Gemcitabine with Erlotinib for Unresected Pancreatic Cancer.  

Science.gov (United States)

PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting ...

2011-05-01

400

Prenatal exposure to ionizing radiation and subsequent development of seizures  

International Nuclear Information System (INIS)

Seizures are a frequent sequela of impaired brain development and can be expected to affect more children with radiation-related brain damage than children without such damage. This report deals with the incidence and type of seizures among survivors prenatally exposed to the atomic bombing of Hiroshima and Nagasaki, and their association with specific stages of prenatal development at the time of irradiation. Fetal radiation dose was assumed to be equal to the dose to the maternal uterus. Seizures here include all references in the clinical record to seizure, epilepsy, or convulsion. Histories of seizures were obtained at biennial routine clinical examinations starting at about the age of 2 years. These clinical records were used to classify seizures as febrile or unprovoked (without precipitating cause). No seizures were ascertained among subjects exposed 0-7 weeks after fertilization at ...

401

Effects of an acute dose of gamma radiation exposure on stem diameter growth, carbon gain, and biomass partitioning in Helianthus annuus  

Energy Technology Data Exchange (ETDEWEB)

Nineteen-day-old dwarf sunflower plants (Helianthus annuus, variety NK894) received a variable dose (0-40 Gy) from a cobalt-60 gamma source. A very sensitive stem monitoring device, developed at Battelle's Pacific Northwest Laboratories, Richland, Washington was used to measure real-time changes in stem diameter. Exposure of plants caused a significant reduction in stem growth and root biomass. Doses as low as 5 Gy resulted in a significant increase in leaf density, suggesting that nonreversible morphological growth changes could be induced by very low doses of radiation. Carbohydrate analysis of 40-Gy irradiated plants demonstrated significantly more starch content in leaves and significantly less starch content in stems 18 days after exposure than did control plants. In contrast, the carbohydrate content in roots of 40-Gy irradiated plants were not significantly different from unirradiated ...

1988-05-25

402

Adaptive response of the chicken embryo to low doses of x-irradiation  

Energy Technology Data Exchange (ETDEWEB)

Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair inhibitors, it is concluded that a reduction of the ...

1995-08-01

403

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To ...

2000-04-01

404

Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses  

International Nuclear Information System (INIS)

A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).

1985-05-01

405

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

406

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...

2003-06-01

407

Study on prepartion of polyethylene ion-exchange capillary by radiation induced graft co-polymerization  

International Nuclear Information System (INIS)

The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.

408

Radiation processed composite materials of wood and elastic polyester resins  

International Nuclear Information System (INIS)

The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of ...

1982-09-19

409

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

410

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

411

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

412

Determination of gamma radiation dose as a post-harvest treatment in mangos infested with the South American fruit fly  

International Nuclear Information System (INIS)

Efforts are being made to determine a gamma radiation dose for mortality of third-instar larvae of Anastrepha fraterculus which infest mangos of the Haden variety of 400 g weight. Four radiation treatments were tested: 0.4 kGy, 0.6 kGy, 0.8 kGy and 1.0 kGy. Using as a criterium for mortality the interruption of the biological cycle between larva and pupa, the following results were achieved: 49.61%, 63.33%, 74.86% and 90.72%. The percentages obtained have been corrected using the Abbot formula. When the criterium was based on no adult emergence, 100% mortality was achieved for the four treatments. (author)

1999-01-01

413

Nuclear fuel behavior at an atomic scale: the contributions of the ab initio calculations and the synchrotron radiation; Comportement du combustible nucleaire a l'echelle atomique: les apports des calculs ab initio et du rayonnement synchrotron  

Energy Technology Data Exchange (ETDEWEB)

This paper presents fundamental researches based on the electronic structure calculations and X absorption spectroscopy, allowing the knowledge on nuclear fuels at an atomic scale. They bring a better understanding of these material behavior to accurate the macroscopic simulation. The calculation methods, the experimental techniques of validation and the ab initio calculations results are detailed. (A.L.B.)

2000-07-01

414

Neon-20 depth-dose relations in water  

Energy Technology Data Exchange (ETDEWEB)

The dose from heavy ion beams has been calculated using a one-dimensional transport theory and evaluated for 670 MeV/amu /sup 20/Ne beams in water. The result is presented so as to be applicable to arbitrary ions for which the necessary interaction data are known. The present evaluation is based on the Silberberg-Tsao fragmentation parameters augmented with light fragment production from intranuclear cascades, recently calculated nuclear absorption cross sections, and evaluated stopping power data. Comparison with recent experimental data obtained at the Lawrence Berkeley Laboratory reveals the need for more accurate fragmentation data.

1984-05-01

415

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat ...

2005-11-23

416

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...

417

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin ...

2010-08-18

418

Study of somatic radiation effects in environment  

International Nuclear Information System (INIS)

A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).

419

Radiation hardening of semiconductor parts  

International Nuclear Information System (INIS)

This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.

420

Inactivation of aflatoxin B1 by using the synergistic effect of hydrogen peroxide and gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.

1989-02-01

421

Accelerated-aging tests for predicting radiation degradation of organic materials  

Energy Technology Data Exchange (ETDEWEB)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-03-01

422

Accelerated-aging tests for predicting radiation degradation of organic materials  

International Nuclear Information System (INIS)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-01-01

423

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

424

Improvement of wood quality used in Syria by irradiation polymerization  

International Nuclear Information System (INIS)

Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In ...

2010-04-01

425

Gene expression analysis after low dose ionising radiation exposure of the developing organism  

International Nuclear Information System (INIS)

Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two ...

2007-09-01

426

Envelope correlation in (N, N) MIMO antenna array from scattering parameters  

DEFF Research Database (Denmark)

A simple closed-form equation to calculate the envelope correlation between any two receiver or transmitter antennas in a multi-input multi-output (MIMO) system of an arbitrary number of elements is derived. The equation uses the scattering parameters obtained at the antenna feed point to calculate the envelope correlation coefficient. This approach has the advantage that it does not require knowledge of the antenna radiation pattern. Numerical data that include conductor and permittivity loss are shown to validate the approach. Using the scattering parameters for calculating the envelope correlation is less laborious and relatively cheaper, as compared to the radiation pattern approach.

2006-01-01

427

The denoising of Monte Carlo dose distributions using convolution superposition calculations  

International Nuclear Information System (INIS)

Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. ...

2007-09-07

428

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per ...

1979-01-01

429

Modeling human risk: Cell & molecular biology in context  

Energy Technology Data Exchange (ETDEWEB)

It is anticipated that early in the next century manned missions into outer space will occur, with a mission to Mars scheduled between 2015 and 2020. However, before such missions can be undertaken, a realistic estimation of the potential risks to the flight crews is required. One of the uncertainties remaining in this risk estimation is that posed by the effects of exposure to the radiation environment of outer space. Although the composition of this environment is fairly well understood, the biological effects arising from exposure to it are not. The reasons for this are three-fold: (1) A small but highly significant component of the radiation spectrum in outer space consists of highly charged, high energy (HZE) particles which are not routinely experienced on earth, and for which there are insufficient data on biological effects; (2) Most studies on the biological effects of radiation to date have been ...

1997-06-01

430

Radioiodine dosimetry and prediction of consequences of thyroid exposure of the Russian population following the Chernobyl accident  

International Nuclear Information System (INIS)

In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The ...

431

The preliminary success of ALARA implementation in Daya Bay NPP  

International Nuclear Information System (INIS)

Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for ...

2000-05-01

432

Gravitational waves from the big bang  

Energy Technology Data Exchange (ETDEWEB)

The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.

1980-12-20

433

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron ...

2002-05-20

434

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover ...

2006-11-13

435

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements ...

2005-11-23

436

On-site radiation exposure in severe reactor accidents: Scoping study  

Energy Technology Data Exchange (ETDEWEB)

The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses ...

1990-09-01

437

Dose and temporary characteristics of the changes in the amount of nucleic acids in leucocytes of irradiated rats  

International Nuclear Information System (INIS)

An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their ...

438

Age and carcinogenesis of "2"3"9Pu  

International Nuclear Information System (INIS)

The late effects of "2"3"9Pu have been studied after its administration to perinatal, juvenile and adult rats. Adults and weanlings were injected intravenously, newborns intracardially and 19-day foetuses by intravenous injection of the dam. Dose levels were selected to deliver radiation doses of approximately 7, 23, or 70 rads to the femur of all ages during the first 10 days post injection; in general these values were achieved as shown by tissue analysis. Dose rates subsequently diverged, resulting in widely varying cumulative radiation doses for the four age groups. Survival times of rats exposed post-natally were progressively decreased by increasing dose. No decrement in survival was found for those exposed prenatally. Bone tumour incidence was increased by exposure to Pu in all age groups. The younger rats were less sensitive on an ...

1979-03-30

439

Radiation exposure to anesthesiologist and nurse in the orthopedic room  

International Nuclear Information System (INIS)

We report the radiation exposure dose received by the anesthesiologist and nurse in the orthopaedic operating room, when a fluoroscopic image intensifier is in use. This study was done in 12 femoral neck fracture operations performed from January to May 1995. Radiation was monitored with the MYDOSE MINIX PDM 107 made by Aloka Co. which were attached in front and behind the nurse's lead apron, in front of the lead apron of the anesthesiologist. The average imaging time was 9.78 min. The average radiation dose in front of the anesthesiologist is lead apron was 2.08#mu#SV, and in front and behind the nurse's lead apron were 5.67#mu#SV, 0.08#mu#SV respectively. This study and review of the literature indicate that the operating room anesthesiologist and nurse receive a lower exposure than the orthopaedist. We can disregard the problem of radiation exposure to the ...

440

Environmental impact assessment around TRIGA research reactor  

International Nuclear Information System (INIS)

Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by ...

1985-04-01

441

Effective radiation therapy on two cases of primary Ewing's sarcoma of the rib  

International Nuclear Information System (INIS)

Two cases of primary Ewing's sarcoma of the rib are reported, in which radiation therapy was quite effective. Case 1 was an 18-year-old female who had had an operation and radiation therapy for Ewing's sarcoma of the left 7th rib. She was referred to our hospital after a recurrent tumor was found. Radiation therapy (tumor dose 46.2 Gy) and chemotherapy were given. The tumor disappeared and there has been no relapse for 1 year and 3 months after the treatment. Case 2 was a 2-year-old-infant. Radiation therapy (tumor dose 74 Gy) was given for primary Ewing's sarcoma of the left 6th rib. The tumor became small and was successfully removed at operation. There has been no relapse or distant metastasis for 8 months following the operation. We emphasize the importance of multidisciplinary treatment in case 1 and the usefulness of preoperative radiotherapy in case 2. ...

442

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was ...

2007-03-15

443

Enjebi Island dose assessment  

Energy Technology Data Exchange (ETDEWEB)

We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral ...

1987-07-01

444

Verification of the Gaspar dose assessment module used in Maxigasp and Popgasp  

Energy Technology Data Exchange (ETDEWEB)

The GASPAR module utilized in MAXIGASP and POPGASP has been verified by hand calculations. The program operates as documented by the NRC [Eckerman et. al. 1980]. Equations used in the code to calculate downwind deposition rates, concentrations in air, on ground surfaces, and in vegetables, meat, and milk are provided in this report.

1992-12-31

445

Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice  

International Nuclear Information System (INIS)

A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse ...

446

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an input fluence map. The ...

2002-08-01

447

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

448

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -I. 6. Neutronics Analyses for Beamline Upgrades to the High Flux Isotope Reactor  

International Nuclear Information System (INIS)

The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...

2001-06-17

449

Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.

2006-01-01

450

Cobalt release from PCA steel during possible fusion reactor accidents  

Energy Technology Data Exchange (ETDEWEB)

Possible accident scenarios for a fusion reactor include breaches in the vacuum or cooling system. Intruding air or steam could react with structural or plasma facing materials, possibly mobilizing radioactive isotopes. Safety assessments must consider the early dose at the site boundary from the release of these activated materials. Previous calculations have indicated that cobalt isotopes dominate dose calculations for designs using stainless steel. Values used in these calculations, however, had been largely determined by the measurement limits of the chemical analysis methodology instead of measured releases. The purpose of the current study was to refine the analytical method to reduce the limit for detecting cobalt, and then test PCA steel in air and steam between 973 and 1473 K. Goals were to obtain more accurate measurements of cobalt mobilization in terms of g/m{sup ...

1995-01-01

451

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose ...

2004-12-01

452

Radiation hardening of CMOS-based circuitry in SMART transmitters  

International Nuclear Information System (INIS)

Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a ...

453

Radiation effects on MOS devices and radiation-hard CMOS technologies  

International Nuclear Information System (INIS)

Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. ...

454

Modulating factors in the expression of radiation-induced oncogenic transformation  

Energy Technology Data Exchange (ETDEWEB)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-08-01

455

Modulating factors in the expression of radiation-induced oncogenic transformation  

International Nuclear Information System (INIS)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-01-01

456

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the ...

2006-02-24

457

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...

2009-03-01

458

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

459

Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation  

International Nuclear Information System (INIS)

Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for different times.

460

The effects of cosmic radiation on implantable medical devices  

Energy Technology Data Exchange (ETDEWEB)

Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset ...

1996-12-31

461

Calculations of the self-amplified spontaneous emission performance of a free-electron laser.  

Energy Technology Data Exchange (ETDEWEB)

The linear integral equation based computer code (RON: Roger Oleg Nikolai), which was recently developed at Argonne National Laboratory, was used to calculate the self-amplified spontaneous emission (SASE) performance of the free-electron laser (FEL) being built at Argonne. Signal growth calculations under different conditions are used for estimating tolerances of actual design parameters. The radiation characteristics are discussed, and calculations using an ideal undulator magnetic field and a real measured magnetic field will be compared and discussed.

1999-04-20

462

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

Energy Technology Data Exchange (ETDEWEB)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18{sup 0}C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4{sup 0}C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation ...

1990-01-01

463

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

International Nuclear Information System (INIS)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18"0C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4"0C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation damage of ...

464

Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K  

Energy Technology Data Exchange (ETDEWEB)

Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with temperature. The melting point of each sample was also ...

1994-08-15

465

Studies on radiation induced changes in bovine hemoglobin type A  

International Nuclear Information System (INIS)

In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the ...

466

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

Energy Technology Data Exchange (ETDEWEB)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical ...

1982-04-01

467

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

International Nuclear Information System (INIS)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical ...

1982-01-01

468

Induction of apoptosis in chicken bursal B cells  

Energy Technology Data Exchange (ETDEWEB)

Cell death in general can be a physiological process of cell number regulation in tissue, or it can be the result of exo or endogenous injuries, such a low-dose of radiation. Chicken B cell population in the bursa of Fabricius are very susceptible to PCD. Our present studies concern the development of radiation damage of chicken defence mechanisms. In 6 experiments pathogen free chicken were irradiated by gamma rays with the total doses of 0.25, 0.5, 1.0, 2.0 and 4.0 Gy. The induction of apoptosis was checked by Flow-cyto-meter 12 h after irradiation in bursa cell suspension. There is some increase in the number of induced apoptotic cells 12 h after irradiation at the dose 0.5-.4.0 Gy. There were no significant changes in the proportion of proliferating lymphocytes (G2 M), but cellularity decreased significantly at dose 2.0 and 4.0 Gy/12 h after irradiation. ...

1997-03-01

469

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972. Hanford Environmental Dose Reconstruction Project  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate ...

1992-07-01

470

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...

1984-12-01

471

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...

1984-01-01

472

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 ...

2010-03-15

473

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate ...

1986-01-01

474

Theoretical considerations for SRAM total-dose hardening  

International Nuclear Information System (INIS)

The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented.

475

Possible processes of abiogenic synthesis of biologically important compounds on surface of small bodies in the Solar System  

International Nuclear Information System (INIS)

A mixture of aminoacids was irradiated by a scattered proton beam, its energy varying from 4 to 6.6 MeV, by doses up to 5 x 10"1"1 proton/cm"2 for studying the potentiality of abiogenic synthesis of biologically important compounds in space. It was ascertained that increase in the radiation dose and reduction of proton energy involve increase in effectiveness both of destruction of the initial aminoacid (tryptophan, tyrosine, glycine) and synthesis of the relevant dipeptide. Essential influence of mineral substrate on abiogenic synthesis of natural nucleotides under the action of diverse energy sources was pointed out

2004-04-01

476

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

477

Development and utilization of the nominal standard dose for the tolerance dose to sound tissue with radiation t: m1herapy  

International Nuclear Information System (INIS)

The utilization of the Ellis-formula for the determination of the tolerance of normal connective tissue is described. Beyond this, the formula is adapted to so-called critical organs. The individual suppositions implicated by the Ellis-formula are commented. Because of the verifyable congruency of the Ellis-formula with data obtained in clinical practice also by other authors, this conception is presented for the provisional determination of the limits of tolerance of normal tissue together with a computerized programme elaborated for use in different therapeutic techniques. (orig.).

1976-01-01

478

Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning  

International Nuclear Information System (INIS)

This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on ...

2003-09-07

479

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with ...

1997-05-01

480

Effects of low-level radiation upon the hematopoietic steam cell: implications for leukemogenesis  

Energy Technology Data Exchange (ETDEWEB)

These studies have addressed firstly the effect of single small doses of x-ray upon murine hematopoietic stem cells to obtain a better estimate of the D/sub q/. It is small, of the order of 20 rads. Secondly, a dose fractionation schedule tht does not kill or perturb the kinetics of hemopoietic cell proliferation was sought in order to investigate the leukemogenic potential of low level radiation upon an unperturbed hemopoietic system. The studies reported herein show tht 1.25 rads every other day decrease the CFU-S content of bone marrow by the time 40 rads are accumulated. Studies on the effect of 0.5, 1.0, 2.0, and 3.0 rads 3 times per week are under way. Two rads 3 times per week produced a modest decrease in CFU-S content of bone marrow after an accumulation of 68 rads. With 3.0 rads 3 times per week an accumulation of 102 rads produces a significant decrease in CFU-S content of bone marrow. Dose ...

1983-01-01

481

Effective equivalent dose and radiation risk in radionuclide diagnostics estimated in patients of the Nuclear Medicine Department of the Medical Academy 'Carl Gustav Carus' Dresden  

International Nuclear Information System (INIS)

7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x ...

1986-01-01

482

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

483

A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT  

International Nuclear Information System (INIS)

Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a photon is sampled in the ...

2005-04-01

484

Wood-polymer composites. Polymerization of methyl-metacrylate in Pinus strobus var. chiapensis wood by gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

To obtain Pinus wood-plastic composites, wood samples were impregnated with methyl methacrylate and polymerized by the use of gamma rays from a /sup 60/Co at different dose exposure and total dose. The best percentage of polymerization was obtained with the exposure of 2.0 MR of gamma radiation. It was found that the impregnation and polymerization, determined by the density values along the samples were uniform. The density became 2.6 times higher in relation to the control samples. The storage of the impregnated wood samples showed losses of the monomer, even when wrapped with aluminum or polyethylene film. It is recommended that the wood samples should be irradiated soon after impregnation.

1984-12-01

485

UK regulations for NORM [naturally occurring radioactive material  

International Nuclear Information System (INIS)

The primary UK legislation relating to the use of radioactive materials are the Radioactive Substances Act 1993 (RSA, 1993) and the Ionising Radiations Regulations 1999 (IRR, 1999). These implement the European Union's Basic Safety Standards Directive (EUBSS) (EC, 1996). The Radioactive Substances Act 1993 (RSA93) regulates the accumulation, storage and disposal of radioactive waste, principally to control potential doses to members of the public. The Ionising Radiations Regulations 1999 (IRR, 1999) deal primarily with regulating the doses that people receive at work. Both of these pieces of legislation apply to the use of materials containing naturally occurring radionuclides. Historically UK regulations relating to radioactive materials have covered both artificial and natural radionuclides

2002-09-23

486

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

487

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

488

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

489

Somatic effects in nuclear medicine and radiology  

International Nuclear Information System (INIS)

Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.

1999-01-01

490

Effect of gamma rays on grafting parameters and liquid retention property of cassava starch-g-PAN  

International Nuclear Information System (INIS)

Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.

1992-10-20

491

Effect of gamma radiation on chlorophylls contents, net photosynthesis and respiration of chlorella pyrenoidosa  

International Nuclear Information System (INIS)

The effect of five doses of gamma radiation: 10, 100, 500, 1000 and 5000 Gy on chlorophylls content, net photosynthesis and respiration of chlorella pyrenoidosa has been studied. A decrease in chlorophylls levels is produced after irradiation at 500, 1000 and 5000 Gy, being, at first 'b' chlorophyll affected to a greater extent than 'a' chlorophyll. Net photosynthesis and respiration decline throughout the time of the observations after irradiation, this depressing effect being much more remarkable for the first one. Net photosynthesis inhibition levels of about 30% have got only five hours post irradiation at a dose of 5000 Gy. (author).

492

Channeling studies of radiation damage in metal-silicides  

Science.gov (United States)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.

1978-01-01

493

Channeling studies of radiation damage in metal-silicides  

International Nuclear Information System (INIS)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.

494

The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 ...

1996-09-01

496

Radiative properties of a solar cavity receiver/reactor with quartz window  

British Library Electronic Table of Contents (United Kingdom)

An energy transfer and conversion model for high-temperature solar cavity receivers has been developed using the transport behaviour of solar radiation as described by the spectral radiative exchange factors. A Monte-Carlo ray-tracing method coupled with optical properties was adopted, to predict radiation characteristics of the solar collector system by calculating radiative exchange factors. A cavity receiver with a plano-convexo quartz window was proposed, based upon the directional characteristics of the focal flux and the redistribution effect of the quartz window. Parametric studies on the windowed receiver provided a more uniform flux distribution, higher efficiency and lower loss than the windowless receivers. The predicted results serve as a design reference for the solar receiver...

2011-01-01

497

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...

2005-03-18

498

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...

1996-09-01