Energy Technology Data Exchange (ETDEWEB)
Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)
2005-11-01
Numerical heat transfer studies of PCMs used in a box-type solar cooker
Energy Technology Data Exchange (ETDEWEB)
Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heat exchanger container materials in the numerical calculations. The large value of thermal conductivity of heat exchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent ...
2008-05-15
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to determine the thermal reliability of stearic acid, palmitic acid, myristic acid and lauric acid as latent heat energy storage materials with respect to various numbers of thermal cycles. The fatty acids, as phase change materials (PCMs), of industrial grade (purity between 90% and 97%) were subjected to accelerated thermal cycle tests. The differential scanning calorimetry (DSC) analysis technique was applied to the PCMs after 0, 120, 560, 850 and 1200 melt/freeze cycles in order to measure the melting temperatures and the latent heats of fusion of the PCMs. The DSC results indicated that the change in melting temperature for the PCMs was in the range of 0.07-7.87 {sup o}C, and the change in latent heat of fusion was -1.0% to -27.7%, except for stearic acid between 560 and 1200 melt/freeze cycles. However, the decrease in the ...
2003-08-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to determine the thermal reliability of stearic acid, palmitic acid, myristic acid and lauric acid as latent heat energy storage materials with respect to various numbers of thermal cycles. The fatty acids, as phase change materials (PCMs), of industrial grade (purity between 90% and 97%) were subjected to accelerated thermal cycle tests. The differential scanning calorimetry (DSC) analysis technique was applied to the PCMs after 0, 120, 560, 850 and 1200 melt/freeze cycles in order to measure the melting temperatures and the latent heats of fusion of the PCMs. The DSC results indicated that the change in melting temperature for the PCMs was in the range of 0.07-7.87 deg. C, and the change in latent heat of fusion was -1.0% to -27.7%, except for stearic acid between 560 and 1200 melt/freeze cycles. However, the decrease in the ...
2003-08-01
Low temperature latent heat thermal energy storage - heat storage materials
Energy Technology Data Exchange (ETDEWEB)
Heat-of-fusion storage materials for low temperature latent heat storage in the temperature range 0-120 C are reviewed. Organic and inorganic heat storage materials classified as paraffins, fatty acids, inorganic salt hydrates and eutectic compounds are considered. The melting and freezing behavior of the various substances is investigated using the techniques of Thermal Analysis and Differential Scanning Calorimetry. The importance of thermal cycling tests for establishing the long-term stability of the storage materials is discussed. Finally, some data pertaining to the corrosion compatibility of heat-of-fusion substances with conventional materials of construction is presented.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
1999-08-31
Energy Technology Data Exchange (ETDEWEB)
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
1999-08-31
Performance characteristics of a natural circulation cooling/latent heat storage system
Energy Technology Data Exchange (ETDEWEB)
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the ...
1987-09-25
Monitoring global land surface drought based on a hybrid evapotranspiration model
British Library Electronic Table of Contents (United Kingdom)
The latent heat of evapotranspiration (ET) plays an important role in the assessment of drought severity as one sensitive indicator of land drought status. A simple and accurate method of estimating global ET for the monitoring of global land surface droughts from remote sensing data is essential. The objective of this research is to develop a hybrid ET model by introducing empirical coefficients based on a simple linear two-source land ET model, and to then use this model to calculate the Evaporative Drought Index (EDI) based on the actual estimated ET and the potential ET in order to characterize global surface drought conditions. This is done using the Global Energy and Water Cycle Experiment (GEWEX) Surface Radiation Budget (SRB) products, AVHRR-NDVI products from the Global Inventory ...
2011-01-01
Thermal and heat transfer characteristics in a latent heat storage system using lauric acid
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The present study deals with two subjects. The first one is to determine the thermal properties of lauric acid (LA)-stearic acid (SA), myristic acid (MA)-palmitic acid (PA) and palmitic acid (PA)-stearic acid (SA) eutectic mixtures as latent heat storage material. The properties were measured by the differential scanning calorimetry (DSC) analysis technique. The second one is to study the thermal reliability of these materials in view of the change in their melting temperatures and latent heats of fusion with respect to repeated thermal cycles. For this aim, the eutectic mixtures were subjected to 360 repeated melt/freeze cycles, and their thermal properties were measured after 0, 90,1 80 and 360 thermal cycles by the technique of DSC analysis. The DSC thermal analysis results show that the binary systems of LA-SA in the ratio of 75.5:24.5 wt.%, MA-PA in the ratio of 58:42 wt.% and PA-SA in the ratio of ...
2004-02-01
Performance analysis on a hybrid air-conditioning system of a green building
Energy Technology Data Exchange (ETDEWEB)
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a ...
2006-05-15
Thermal energy storage performance of fatty acids as a phase change material
Energy Technology Data Exchange (ETDEWEB)
Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0{sup o}C to 61.20{sup o}C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the ...
2006-01-21
International Nuclear Information System (INIS)
To clarify the effects of the principal factors that govern the thermal fragmentation of a molten metallic fuel jet in the course of fuel-coolant interaction, which is important in evaluating the sequence of core disruptive accidents (CDAs) for metallic fuel fast reactors, basic experiments were carried out using molten metallic fuel simulants (copper and silver) and a sodium pool.Fragmentation of a molten metal jet with a solid crust was caused by internal pressure produced by the boiling of sodium, which is locally entrapped inside the jet due to hydrodynamic motion between the jet and the coolant. The superheating and the latent heat of fusion of the jet are the principal factors governing this type of thermal fragmentation. On the other hand, the effect of the initial sodium temperature is regarded as negligible in the case of thermal conditions expected to result in CDAs for practical metallic fuel cores. Based on the fragmentation data ...
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
MAGMA is a FORTRAN computer code designed to viscous flow in in situ vitrification melt pools. It models three-dimensional, incompressible, viscous flow and heat transfer. The momentum equation is coupled to the temperature field through the buoyancy force terms arising from the Boussinesq approximation. All fluid properties, except density, are assumed variable. Density is assumed constant except in the buoyancy force terms in the momentum equation. A simple melting model based on the enthalpy method allows the study of the melt front progression and latent heat effects. An indirect addressing scheme used in the numerical solution of the momentum equation voids unnecessary calculations in cells devoid of liquid. Two-dimensional calculations can be performed using either rectangular or cylindrical coordinates, while three-dimensional calculations use rectangular ...
1991-11-01
Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes
Energy Technology Data Exchange (ETDEWEB)
This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.
2011-06-01
Accuracy improvement of T-history method for measuring heat of fusion of various materials
Energy Technology Data Exchange (ETDEWEB)
T-history method, developed for measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and convenience with no sampling process. However, some improper assumptions in the original method, such as using a degree of supercooling as the end of latent heat period and neglecting sensible heat during phase change, can cause significant errors in determining the heat of fusion. We have improved this problem in order to predict better results. The present study shows that the modified T-history method is successfully applied to a variety of PCMs such as paraffin and lauric acid having no or a low degree of supercooling. Also it turned out that selected periods for sensible and latent heat do not significantly affect the accuracy of heat- of-fusion. As a result, ...
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
With the development of the latent heat store and its inclusion in the conventional heating control of cars, success has been achieved both in increasing comfort and in making an important contribution to safety of driving. Great store is set in development of the system on its environmental friendliness, for example by the thorough use of environmentally friendly and reusable materials. This also means the use of clean materials. It was shown that the latent heat store (apart from the aspects of comfort and safety of driving) can also make a contribution to saving fuel and reducing the exhaust gas. The sum total of the advantages makes it clear that the latent heat store introduced here is a very environmentally friendly system with multi-functional properties. (orig.) [Deutsch] Mit der Entwicklung des Latentwaermespeichers und seiner ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper presents the experimental measurements of the transmittivity of commercial grade stearic acid. The effects of temperature and thickness on transmittance have been studied. The study indicates that the effect of temperature on the transmittance of stearic acid in the liquid phase is not significant. However, it is highly dependent on temperature during the solidification process. Because of its low thermal conductivity and high transmittivity, it can be used as a transparent insulating material. (Author)
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
Land surface parameterization schemes such as the Simple Biosphere Model (SiB2) have found considerable use in climate simulation models, where they provide lower boundary conditions in the form of surface sensible and latent heat fluxes. A methodology is described to apply models of this type at high resolution, using data from the Department of Energy{close_quote}s Cloud and Radiation Testbed in Oklahoma and Kansas, to determine the spatial variations of heat fluxes over the domain and to determine area-weighted flux averages for use in single-column model studies. Data from a dense array of meteorological instruments are interpolated to provide the wind, temperature, vapor pressure, radiation, and precipitation values needed by SiB2. The state of the vegetation is characterized through the use of the normalized difference vegetation index determined from satellites. The performance of the SiB2 model is evaluated by ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
The ultrafine fibers based on the composites of polyethylene terephthalate (PET) and a series of fatty acids, lauric acid (LA), myristic acid (MA), palmitic acid (PA), and stearic acid (SA), were prepared successfully via electrospinning as form-stable phase change materials (PCMs). The morphology and thermal properties of the composite fibers were studied by field emission scanning electron microscopy (FE-SEM) and differential scanning calorimetry (DSC), respectively. It was found that the average fiber diameter increased generally with the content of fatty acid (LA) in the LA/PET composite fibers. The fibers with the low mass ratio maintained cylindrical shape with smooth surface while the quality became worse when the mass ratio is too high (more than 100/100). Moreover, the latent heat of the composite fibers increased with the increase of LA content and the phase transition temperature of the fibers have no obvious variations compared with ...
2008-11-15
Enhancement of convective heat transfer by using microencapsulated PCM slurry
Energy Technology Data Exchange (ETDEWEB)
As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, ...
2005-04-01
Horizontal and Vertical Structure of Easterly Waves in the Pacific ITCZ
Outgoing longwave radiation (OLR) and low-level wind fields in the Atlantic and Pacific Intertropical Convergence Zone (ITCZ) are dominated by variability on synoptic time scales primarily associated with convectively coupled easterly waves during boreal summer and fall. This study uses spectral filtering of observed OLR data to capture the convective variability coupled to Pacific easterly waves. Filtered OLR is then used to isolate easterly waves in winds, temperature and humidity fields from TAO/TRITON and TAO/EPIC buoys, radiosondes, and gridded reanalysis products. Our analysis shows that while some of the Pacific easterly waves originate in the Atlantic, most of the waves appear to form and strengthen within the Pacific. Pacific easterly waves have wavelengths of 3300-5500 km and phase speeds of 9-13 m s-1. A warm, moist boundary layer is observed ahead of the convective wave, with moisture lofted quickly through the troposphere by deep convection, followed by a cold, dry signal ...
2006-12-01
Thermal energy storage system using stearic acid as a phase change material
Energy Technology Data Exchange (ETDEWEB)
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM ...
2001-07-01
Experimental assessment of energy storage via variable speed compressor
British Library Electronic Table of Contents (United Kingdom)
In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The present study includes thermal stability of some fatty acids as phase change materials (PCMs). The selected fatty acids were stearic, palmitic, myristic and lauric acid with melting temperatures between 40-63{sup o}C and industrial-grade with 90-95% purity. Latent heat storage capacity and phase transition temperature of the PCMs were determined by Differential Scanning Calorimetry (DSC) technique as a function of after repeated thermal cycles such as 40, 410, 700 and 910. The present work also comprises the investigation of corrosion resistance of some construction materials to the fatty acids over a long period. The containment materials tested were stainless steel (SS 304 L), carbon steel (steel C20), aluminium (Al) and copper (Cu). Gravimetric analysis as mass loss (mg/cm{sup 2}), corrosion rate (mg/day) and a microscopic or metallographic investigation were performed for corrosion tests after 910 thermal cycles. DSC measurements showed ...
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
Fatty acids such as stearic acid (SA), palmitic acid (PA), myristic acid (MA), and lauric acid (LA) are promising phase change materials (PCMs) for latent heat thermal energy storage (LHTES) applications, but high cost is the most drawback which limits the utility area of them in thermal energy storage. The use of fatty acids as form-stable PCM will increase their feasibilities in practical LHTES applications due to reduced cost of the energy storage system. In this regard, a series of fatty acid/poly(methyl methacrylate) (PMMA) blends, SA/PMMA, PA/PMMA, MA/PMMA, and LA/PMMA were prepared as new kinds of form-stable PCMs by encapsulation of fatty acids into PMMA which acts as supporting material. The blends were prepared at different mass fractions of fatty acids (50, 60, 70, 80, and 90% w/w) to reach maximum encapsulation ratio. All blends were subjected to leakage test by heating the blends over the melting temperature of ...
2008-02-15
On the solid-fluid transition zone in welding analysis
Energy Technology Data Exchange (ETDEWEB)
Equilibrium and energy equations have been developed in describing the solid-fluid transition zone during the melting and solidification of the binary alloys. Due to the existence of the transition region exhibited both solid and fluid phases at the same material point from continuum point of view, mixture theory was utilized to analyze the region. Unlike the Stefan problem, the latent heat due to the phase change appears as a source term in the heat equation. The molten fluid is treated as a thermoviscous and incompressible fluid, whereas the solid is thermoviscoplastic described by the Bodner-Partom/Walker type of constitutive equations. Thermal mechanical behaviors of the solid and the fluid phases are determined separately because of insignificant mechanical interactions between them. Volume fractions of the phases are obtained according to the equilibrium phase diagram. The simulation process of the transition zone and ...
1993-01-01
Energy balance of the area influenced by brown coal mining in three phases
The change in the energy flow on land used for brown coal mining is examined. Terrain mapping was used to obtain land use data for a 14 km{sup 2} mining area and its surroundings. The focus is on the proportion of incident solar energy that is changed to latent heat during evapotranspiration. Each land use unit was assigned an average value for evapotranspiration for the growing season. Satellite data of surface temperature and surface wetness values show incident radiation converted to heat. Relationships between evapotranspiration and surface temperature and between wetness index and evapotranspiration were verified. The results confirm the hypothesis that changes in land use can have a significant effect on total average evapotranspiration. 18 refs., 5 figs., 3 tabs.
2005-07-01
Recovery of Water from Boiler Flue Gas
Energy Technology Data Exchange (ETDEWEB)
This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature and low temperature ...
2008-09-30
Energy Technology Data Exchange (ETDEWEB)
The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase ...
1994-12-31
The capric-lauric acid and pentadecane combination as phase change material for cooling applications
Energy Technology Data Exchange (ETDEWEB)
The mixture of 65 mol% capric acid and 35 mol% lauric acid (C-L acid) is a potential latent heat storage material. However, its melting temperature of 18.0 {sup o}C is quite high for low-temperature thermal energy storage. Addition of pentadecane, with a melting point of 9.9 {sup o}C, is proposed. The thermal characteristics of the combination of the C-L acid with pentadecane (CL:P) in different volume ratio are investigated employing the DSC analysis. The actual thermal performance of each CL:P combination is further determined from their radial and axial temperature distribution employing a fabricated thermal storage capsule. The 90:10 CL:P combination manifests an improvement in the melting characteristic of the C-L acid.(author)
2002-03-01
The Stefan Problem Revisited: A Continuum Model of Frost Heave
The classical Stefan problem describes the motion of a solidification front through a uniform half-space in response to a step change in temperature on its boundary. The predictions of such a model can be applied quite accurately to the freezing of water in a porous medium so long as the pore geometry remains unaltered by the passing solidification front. It is observed, however, that in fine-grained porous media, ice has a tendency to form in segregated horizontal bands, known as ice lenses, that disrupt the regular pattern of heat flow through their enhanced consumption of latent heat. This process, known as frost heave, causes significant ground deformation in regions subject to prolonged freezing, and is one of the most important weathering processes in polar and alpine regions. Recent improvements to our understanding of the mechanics of ice lens nucleation and growth are applied here to predict the conditions and ...
2005-12-01
Bioprocess control from a multivariate process trajectory.
A multivariate bioprocess control approach, capable of tracking a pre-set process trajectory correlated to the biomass or product concentration in the bioprocess is described. The trajectory was either a latent variable derived from multivariate statistical process monitoring (MSPC) based on partial least squares (PLS) modeling, or the absolute value of the process variable. In the control algorithm the substrate feed pump rate was calculated from on-line analyzer data. The only parameters needed were the substrate feed concentration and the substrate yield of the growth-limiting substrate. On-line near-infrared spectroscopy data were used to demonstrate the performance of the control algorithm on an Escherichia coli fed-batch cultivation for tryptophan production. The controller showed good ability to track a defined biomass trajectory during varying process dynamics. The robustness of the control was high, despite significant external ...
2003-09-05
Energy Technology Data Exchange (ETDEWEB)
In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are ...
1999-07-01
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for some of the most frequent ...
1980-03-01
Energy Technology Data Exchange (ETDEWEB)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.
1982-10-01
International Nuclear Information System (INIS)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).
1982-01-01
UK PubMed Central (United Kingdom)
Latent inhibition (LI) manifests as poorer conditioning to a CS that has previously been presented without consequence. There is some evidence that LI can be potentiated by reduced mesoaccumbal dopamine...Full Text Available
2011-03-01
UK PubMed Central (United Kingdom)
SummaryAttention deficit hyperactivity disorder (ADHD) is a neurodevelopmental disorder which is most often diagnosed in childhood with symptoms often persisting into adulthood....Full Text Available
2010-01-01
COOLOD, Steady-State Thermal Hydraulics of Research Reactors
International Nuclear Information System (INIS)
1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. ...
Water induction studies in a hydrogen-diesel dual-fuel engine
Energy Technology Data Exchange (ETDEWEB)
Power output of a hydrogen-diesel dual-fuel engine is limited by the onset of knock as the percentage of heat input derived from hydrogen increased beyond a certain limit. Earlier work carried out at the Internal Combustion Engines Laboratory, Indian Institute of Technology, Madras, indicates that this knock sets in when the induced hydrogen exceeds about 60% of input energy at a pilot diesel quantity of 30% of full load diesel amount. At higher rates of hydrogen induction, the richer hydrogen-air mixture is more prone to knocking. Hardly any information is available on the possibilities of improving the knock limited power output of a hydrogen-diesel dual-fuel engine. Water can serve as a powerful internal coolant in decreasing the unburned mixture temperature because of its high latent heat. This paper presents the results of our investigation on improving the knock limited power output when water is inducted with the ...
1987-01-01
Postulated weather modification effects of large energy releases
International Nuclear Information System (INIS)
Postulated impacts of large energy releases were examined in the light of existing technical information. The magnitudes of direct atmospheric modifications were estimated, and the ecological and economic implications of the modifications were explored. Energy releases from energy centers (10 to 40 power plants at a single site) and individual power plant clusters (1 to 4 power plants) were considered. In the atmosphere the energy will exist initially as increased temperature (sensible heat), moisture (latent heat), and air motion (kinetic energy). Addition of energy could result in increased cloudiness and fog, and changed precipitation patterns. A framework for economic analysis of the impacts of the postulated atmospheric modifications was established on the basis of costs and benefits. Willingness-to-pay was selected as the appropriate measure for valuing each impact. The primary and secondary atmospheric modifications ...
1977-01-01
UK PubMed Central (United Kingdom)
Transforming growth factor (TGF)-βs are secreted in large latent complexes consisting of TGF-β, its N-terminal latency-associated peptide (LAP) propeptide, and latent TGF-β...Full Text Available
2000-08-01
Energy Technology Data Exchange (ETDEWEB)
Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.
1980-01-01
Experimental and theoretical studies on humidification-dehumidification-desalination
Energy Technology Data Exchange (ETDEWEB)
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water properties within humidification and ...
2006-07-01
Phase diagram of the ternary system lauric acid-capric acid-naphthalene
Energy Technology Data Exchange (ETDEWEB)
The mixture of lauric acid and capric acid is a potential latent heat storage material. However, its eutectic melting temperature is quite high for low-temperature thermal energy storage. Addition of naphthalene is proposed. The ternary system lauric acid-capric acid-naphthalene has been investigated by differential scanning calorimetry (DSC), visual polythermal and chromatography of gases. The phase diagram is of an incongruent eutectic type. The eutectic mixture contains 18.4mol% lauric acid, 63.1mol% capric acid and 18.5mol% naphthalene and melts at 13.3{sup o}C. The peritectic mixture contains 32.4mol% lauric acid, 48.2mol% capric acid and 19.4mol% naphthalene and peritectic temperature of 16.2{sup o}C. The incongruent compound was analysed to be CH{sub 3}(CH{sub 2}){sub 10}COOH.CH{sub 3}(CH{sub 2}){sub 8}COOH. The melting temperature of the lauric acid-capric acid-naphthalene eutectic mixture makes it suitable for cooling applications.
2004-12-15
Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea
Energy Technology Data Exchange (ETDEWEB)
An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
The buckwheat soup is a mixture of seasonings such as soy sauce, sweet sake, sugar and the like and stock of dried bonito. This paper describes an analysis of the stock manufacturing step, an important step in the manufacture of buckwheat soup, and the setting of stock extraction conditions on the basis of this analysis. If the rate of infiltration of water into the dried bonito is found, it is a very effective finding for setting the thickness of flakes of dried bonito and the extraction time to prepare buckwheat soup industrially. To obtain such knowledge, the time taken for the water to pass through flakes of dried bonito of various thicknesses, to vaporize and to remove latent heat till the temperature of the surfaces of flakes lowers was measured. The thickness of flakes of dried bonito and extraction time were set on the basis of the data thus obtained. Dired bonito was then supplied to a bench scale flow extraction apparatus filled with ...
1997-05-05
Energy Technology Data Exchange (ETDEWEB)
A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The variables collected in the experimental procedures was gathered in the ...
1997-07-01
British Library Electronic Table of Contents (United Kingdom)
An approach to the calculation of the quantity of heat consumed in the process of coal formation is presented. The variability of this parameter in a coalification series is analyzed using coals from the Kuznetsk and Tunguska Basins as an example.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.
1985-08-01
International Nuclear Information System (INIS)
... 5. Formation of the annular two-phase flow regime, with a wavy film on the
1974-01-01
Modeling of snow melting and uniform wetting front migration in a layered subfreezing snowpack
Energy Technology Data Exchange (ETDEWEB)
A method of modeling freeze-thaw cycles of naturally deposited snowpacks is presented. The model involves the Stefan condition as an independent governing equation on the exterior moving boundary to calculate snowpack thinning, flow of water through a variably saturated layered porous medium as described by the Richards equation, and heat conduction with a phase change. The heat conduction problem was treated in two ways. Local heat conduction between a snow grain and its surrounding water film was treated by using a simple energy balance. Global heat conduction with a phase change (the Stefan problem) was introduced to calculate the space-time temperature distribution. In order to handle multiple interior moving boundaries, a specific form of the enthalpy formulation was used for heat conduction with a phase change. Changing material ...
1994-08-01
Heat-transfer augmentation in rod bundles near grid spacers
International Nuclear Information System (INIS)
Heat-transfer augmentation by straight grid spacers in rod bundles is studied for single-phase flow and for post-critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single-phase flow is also examined. Governing heat-transfer mechanisms are analyzed, and predictive formulations are established. For single-phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. The effect of local velocity increasing near swirling spacer is considered. For post critical heat flux (CHF) dispersed flow, the heat transfer by thermal radiation, fin cooling, and vapor convection near the spacer are calculated. The predictions are compared with experimental data with satisfactory agreement.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the effects of combustion chamber specifications and swirl ratios on the heat release and transient heat transfer characteristics. Heat rejection was examined on the basis of heat release calculations using cylinder pressure time histories. Transient surface temperature data obtained from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. The results showed good agreement with the heat rejection calculated from cylinder pressure data and that transient heat flux in a piston cavity was reduced with the larger cavity diameter and a higher swirl ratio. On the other hand, a transient heat flux in a ...
1997-09-25
Enhanced heat transfer through oscillatory flow
Energy Technology Data Exchange (ETDEWEB)
The enhancement of longitudinal heat transfer by means of fluid pulsation in a pipe has been investigated analytically and numerically, including the transient state. The effects of pulsation amplitude, frequency, and pipe length on thermal properties such as effective thermal diffusivity and delay time are clarified. Their effects on numerical calculations are also presented and suggestions for efficient numerical calculations of this problem are made concerning the combination of parameters.
1994-03-01
Energy Technology Data Exchange (ETDEWEB)
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the transient heat transfer characteristics. Transient temperature data from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. Transient surface temperature was measured using the thin film thermocouples. At first, the transient heat flux rates calculated from the analysis method used in this paper were compared with the results from FEM. The results showed good agreement. Using this analysis method, the transient heat flux rates were calculated. The tests were performed at 1200 rpm with constant air flow. The parameters that were varied included the fuel rate and injection timing. Based on these results, the present paper discusses the mechanism of heat ...
1997-09-25
Development of a solar thermal storage system suitable for the farmhouse heating in northeast China
Energy Technology Data Exchange (ETDEWEB)
This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable energy.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state temperature is developed. (author)
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
1982-06-01
Dynamic behavior of a solar-heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1987-01-01
Dynamic behavior of a solar heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1986-01-01
Analysis and optimization of convective trapezoidal profile pin fins with internal heat generation
Energy Technology Data Exchange (ETDEWEB)
An analysis of trapezoidal profile convective pin fins, with internal heat generation density is presented. The solution of the optimal problem is also given, when either the desired heat dissipation rate or the volume of the pin is specified. The results are presented graphically and in polynomial forms that are particularly useful for computerized calculations. The effect of the fin`s profile and thermal conductivity upon the optimum dimensions is discussed. An example serves to demonstrate the usefulness of the method.
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
It is planned to bulk-heat a unit cell of a fusion reactor solid-breeder blanket in a fission reactor to study thermo-mechanical and thermal-hydraulic properties of fusion blankets. This study investigates the neutronic feasibility of using the Power Burst Facility (PBF) for this purpose. Heating rates were calculated for a Li/sub 2/O experiment placed in the PBF test space. The ANISN code and a 56-group coupled neutron-gamma library based on FLUNG and VITAMIN C were used to compute the heating rates. The results show that an average heating rate level of 1-3 W/cc can be produced in PBF with a local power profile that should be typical of a fusion blanket unit cell.
1982-11-01
Text Mining Classification, Clustering, and Applications
An extension of data mining, text mining involves the extraction of information and knowledge from unstructured text. This constantly evolving field is increasingly used by major corporations, such as Google, Yahoo, and Microsoft. Featuring contributions from leading researchers in the field, this book provides a detailed overview of text mining theory, applications, and visualization. The theory section discusses text mining, information retrieval, latent semantic analysis, pagerank, latent Dirichlet allocation, and probabilistic relational models. In the section on text mining applications,
2009-01-01
UK PubMed Central (United Kingdom)
The Epstein-Barr virus nuclear antigen (EBNA I) present in latently infected cells is encoded in a 2-kilobase exon contained in the BamHI K viral genomic fragment. This exon is, however, found within...Full Text Available
1985-12-01
Development of an experimental installation for short-lived isotopes production in INR linac
International Nuclear Information System (INIS)
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
2010-01-01
Afterheat assessment for conceptual tokamak reactors
International Nuclear Information System (INIS)
Afterheat represents an important consideration in design of conceptual fusion power reactors, particularly during normal or unplanned shutdown. Afterheat calculations have been undertaken for various generic designs, but with special reference to the Culham DEMO reactor. These calculations have included the redistribution of heating by gamma ray transport. Selected temperature response calculations have been undertaken. (author).
1987-12-01
Thermal performance of phase change wallboard for residential cooling application
Energy Technology Data Exchange (ETDEWEB)
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat storage takes place ...
1997-04-01
Natural-convection cooling of heat-producing radioactive waste in transport and storage casks
International Nuclear Information System (INIS)
The heat transfer characteristics of a newly developed transport and storage cask for vitrified heat-producing radioactive waste from reprocessing are described. The theoretical layout of the cask was tested by measurements on a prototype cask of the scale 1:1. These measurements confirmed the theoretical thermodynamic layout data. They can be described by the function Nu=CxRa"m, with the constant C, but not the constant m, differing for a vertical and a horizontal position of the cask. The measured velocity and temperature profiles of the cask were verified with an existing code for the calculation of heat transfer from finned horizontal cylinders by natural convection. (orig.).
Convection heat loss from a cavity receiver
Energy Technology Data Exchange (ETDEWEB)
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
1984-02-01
A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
1996-12-31
Evaluation of heat exchange rate of GHE in geothermal heat pump systems
Energy Technology Data Exchange (ETDEWEB)
Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal heat ...
2009-12-15
Correlations for the yearly or seasonally optimum salt-gradient solar pond in Greece
Energy Technology Data Exchange (ETDEWEB)
Simple correlations and corresponding nomographs are presented, which express the maximum useful heat received from salt-gradient solar ponds throughout the year or during a specified season of the year, and the corresponding optimum depth of the nonconvective zone in terms of the thickness of the upper convective zone and the temperature under which the maximum useful heat is received. The correlations are valid for the Athens (Greece) area or for regions with a similar climate, because solar radiation and ambient temperature values for Athens have been employed, obtained by a statistical process of hourly measurements over a period of about 20 years. For other climates, it is easy to develop similar correlations using the same methodology, Development of the proposed correlations is based on a method, which simulates the transient operation of the salt-gradient pond using finite-differences, and calculates the useful ...
1993-05-01
International Nuclear Information System (INIS)
The super simulator 'SAMPSON' has been developed to show that there exist certain safety margins for light water reactors under hypothetical severe accidents and to investigate realistic measures of accident management by simulating accidents with a parallel computer. Heat-up of fuel rods and release of fission products from fuels are important factors to evaluate source terms. Models for fuel rod heat-up, hydrogen production due to cladding oxidation and cladding deformation and failure in the core region have been developed in the fuel rod heat-up analysis module. Fuel temperatures were calculated by solving the heat conduction equation. The calculated results for fuel temperature and hydrogen production were compared with CORA-13 experiment results. The comparisons showed prediction capability for the heat-up of fuel rods. The fission ...
1999-04-19
Thermal performance simulation of a solar cavity receiver under windy conditions
British Library Electronic Table of Contents (United Kingdom)
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
2011-01-01
Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test
International Nuclear Information System (INIS)
The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL ...
2010-11-15
International Nuclear Information System (INIS)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL ...
2010-11-01
The influence of heating rate on the response and trapping parameters of {alpha}-Al{sub 2}O{sub 3}:C
Energy Technology Data Exchange (ETDEWEB)
The effects of the heating rate from 0.6 up to 50{sup o}C.s{sup -1} on the thermoluminescence of {alpha}-Al{sub 2}O{sub 3}:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).
1994-12-31
The influence of heating rate on the response and trapping parameters of #alpha#-Al_2O_3:C
International Nuclear Information System (INIS)
The effects of the heating rate from 0.6 up to 50"oC.s"-"1 on the thermoluminescence of #alpha#-Al_2O_3:C are very intensive. The material rapidly loses its high sensitivity as the heating rate increases. The peak shape characteristics, peak maximum and full width at half maximum agree only qualitatively with those theoretically predicted. The trapping parameters calculated by the curve fitting method, the peak shape method, the variable heating rate method and the initial rise method, were found to decrease as the heating rate increases. The validity of the results are discussed in the framework of the kinetic models. (author).
Improvement of the PGV-1000 steam generator in-vessel components
International Nuclear Information System (INIS)
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
1988-01-01
First ICRF heating experiment in the large helical device
Energy Technology Data Exchange (ETDEWEB)
Initial ICRF heating experiment in the LHD was carried out in 1998. One pair of the movable loop antennas was used and the coupling resistance was around one ohm for the low density ECH plasma. The loading characteristics were consistent with the fast wave excitation. By applying the ICRF heating of 300 kW to the ECH target plasma, the diamagnetic energy was increased from 13 kJ to 26 kJ. The heating performance was decided by hydrogen mixture rate on puffing gas. Efficient electron heating was observed at the higher hydrogen gas ratio. These results can be explained by the one dimensional wave analysis calculation on slab plasma model. (J.P.N.)
1999-07-01
Pressure drop and heat transfer in gas-cooled rod bundles
International Nuclear Information System (INIS)
Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).
Convection in the cavity between two rollers: The effect of thermal boundary conditions
Energy Technology Data Exchange (ETDEWEB)
In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.
1991-02-01
Load calculation and system evaluation for electric vehicle climate control
Energy Technology Data Exchange (ETDEWEB)
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV HVAC. These are, vapor compression, ice storage and adsorption systems. These systems ...
1994-09-12
Kelvin-day function for climatic solar heating design
Energy Technology Data Exchange (ETDEWEB)
A method of Kelvin-day function for climatic solar heating design is presented. The long term temperature distribution is used to find the solar fraction for building heating. A solar heating system is considered to provide heat needed up to an auxiliary heater cut-in temperature which is determined by both heat gain of solar heating system and overall heat loss coefficient of the building. The amount of auxiliary heat needed is calculated from a Kelvin-day value at this cut-in temperature. The cut-in temperature will change from different solar heating system designs, and the Kelvin-day value at this cut-in temperature will be varied. By using the numerical curve-fitting method, the Kelvin-day value at any temperature base can be expressed into a second order algebraic equation, ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Three systems for the heat supply in the built environment have been compared for the costs, the energy consumption and emissions of CO{sub 2}, NO{sub x} and SO{sub 2}. The heating systems compared are based on central heating boilers, district heating systems in combination with combined steam and gas turbine cycles, and heating by means of several gas engines. From the results it appears that the boilers demand the lowest investments. The district heating systems are more expensive. Both heating systems, however, show considerable savings of energy (55 to 70%). The exploitation costs depend strongly on the fuel price scenarios used and the assumptions with regard to interest and inflation. The emissions of CO{sub 2} are also considerably lower for both combined heat and power generating systems. The use of gas engines ...
1991-07-01
Survey of the core helium flash with dynamic convection
Energy Technology Data Exchange (ETDEWEB)
Calculations have been performed to study the dependence on model parameters of convectively heating the region interior to the core convection zone for core helium flash models. We find that interior heating always occurs on a time scale significantly shorter than the evolutionary time scale even at the peak of the flash.
1983-06-15
Steam generator PGV-1000 thermal-hydraulics
International Nuclear Information System (INIS)
The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.
1995-09-21
Performance of large LWR system codes in calculating the steam-generator heat-transfer behavior
Energy Technology Data Exchange (ETDEWEB)
This paper presents a series of modeling experiences and problems in simulating the thermal-hydraulic behavior of large PWR steam generators using the RELAP4 and RELAP5 computer codes. Sensitivity studies investigating the heat transfer characteristics of both once-through and U-tube steam generators are discussed. Suggestions and recommendations are given for effective use and potential future improvements of these codes.
1982-01-01
Investigation on natural convection decay heat removal for the EFR: Status of the program
International Nuclear Information System (INIS)
The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)
1991-11-05
Contribution of surface rayleigh waves to the heat capacity of poly(vinyl chloride)
British Library Electronic Table of Contents (United Kingdom)
The method of surface acoustic waves is employed to determine the frequency and temperature dependences of the molar heat capacity of poly(vinyl chloride) on the contribution of Rayleigh local components of the longitudinal and transverse vibrations of structural units of the polymer. The calculated and experimental data are compared in terms of their dependence on the relaxation state of the system.
2009-01-01
Optimum profiles for asymmetrical longitudinal fins in annular ducts
Energy Technology Data Exchange (ETDEWEB)
In the present work the geometry of annular ducts with asymmetrical longitudinal fins is optimized in order to enhance the heat transfer under laminar coolant flow conditions. The heat transferred is also maximized for a given amount of material or hydraulic resistance. Polynomial profiles are assigned to the two lateral fin surfaces. Velocity and temperature distributions on the annular duct cross section are determined with the help of a finite-element model. A global heat transfer coefficient and an equivalent Nusselt number are then calculated. Lastly, optimum asymmetrical fins obtained by means of a genetic algorithm are shown for different situations and their performance is compared with those of optimum symmetrical fins.
2000-04-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.
1992-01-01
Oil/electric hybrid heating experiment and demonstration. [Executive summary is a separate volume
Energy Technology Data Exchange (ETDEWEB)
Oil/electric heating systems and energy measuring instrumentation were installed in 50 houses in Deep River, Ontario. These were operated and monitored for two heating seasons to demonstrate their performance and determine the percentage oil placement as a function of heater capacity and control system. All experimental data was stored and processed by computer. It was found that oil furnace utilization efficiency varied from 48 to 59% for an average of 53.5%. Oil displacement ranged from 49 to 83% for 2.5 and 5.0 kW electric heaters controlled by two-stage indoor thermostats. Fuel costs for oil/electric hybrid heating, with 5.0 kW plenum heaters and indoor two-stage thermostats, were 20% less than for oil heating, based on average furnace efficency and 1983 January retail fuel prices. Annual load factors above 37% were achieved for plenum heaters compared to 11.9% for all-electric systems. Space ...
1983-07-01
UK PubMed Central (United Kingdom)
Recent reports confirm that, due to the presence of long-lived, latently infected cell populations, eradication of human immunodeficiency virus type 1 (HIV-1) from infected patients by using antiretroviral...Full Text Available
2003-09-01
UK PubMed Central (United Kingdom)
BackgroundThe long latent stage seen in syphilis, followed by chronic central nervous system infection and inflammation, can be explained by the persistence of atypical cystic and...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundCalcium signaling plays an important role in B lymphocyte survival and activation, and is critically dependent on the inositol-1,4,5-tris-phosphate-induced...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundMalignant catarrhal fever (MCF) is a lethal disease of cattle, characterized by vasculitis, necrosis, and accumulation of activated, dysregulated cytotoxic lymphocytes...Full Text Available
UK PubMed Central (United Kingdom)
Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available
2009-01-01
Adherence with isoniazid for prevention of tuberculosis among HIV-infected adults in South Africa
UK PubMed Central (United Kingdom)
BackgroundTuberculosis (TB) is the most common opportunistic infection in HIV-infected adults in developing countries. Isoniazid (INH) is recommended for treatment of latent TB infection,...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundWith the explosion in data generated using microarray technology by different investigators working on similar experiments, it is of interest to combine results across...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)
2006-07-01
A microscopic model of electronic field noise heating in ion traps
Motional heating of ions in micro-fabricated traps is a challenge hindering experimental realization of large-scale quantum processing devices. Recently a series of measurements of the heating rates in surface-electrode ion traps characterized their frequency, distance, and temperature dependencies, but our understanding of the microscopic origin of this noise is still vague. In this work we develop a theoretical model for the electric field noise which is associated with a random distribution of adsorbed atoms on the trap electrode surface. By using first principle calculations of the fluctuating dipole moments of the adsorbed atoms we evaluate the distance, frequency and temperature dependence of the resulting electric field fluctuation spectrum.Our theory calculates the noise spectrum beyond the standard scenario of two-level fluctuators, by incorporating all the relevant vibrational states. The ...
2011-01-01
Theoretical calculation for the elastic wave velocities and thermodynamic functions of graphite
International Nuclear Information System (INIS)
Based on the generalized gradient approximation (GGA) of density functional theory (DFT) and the full-potential linearized augmented plane wave (FLAPW) at the level including all electrons, the lattice parameters of graphite are calculated and optimized. Some elastic wave velocities transmitted in graphite are deduced. Using the methods of elastic wave velocity method and the atomic displacement method, the Debye frequency of graphite is obtained. The standard heat capacity, entropy, sublimation enthalpy of graphite is deduced at 289.5 k and 1 atm. The calculated results are discussed and compared with experimental data. (authors)
2006-06-01
Electronic structure of one-to-one and defect scandium sulfide
Energy Technology Data Exchange (ETDEWEB)
Self-consistent electronic structure calculations have been performed on two compositions of scandium sulfide ScS and Sc/sub 3/S/sub 4/. The results of the calculation of ScS are similar to those obtained for other transition metal chalcogenides and are in excellent agreement with heat capacity and reflectance measurements as well as UPS experiments. The calculation of the defect structure indicates the creation of sulfur p nonbonding states in metal-deficient ScS. The valency of the metal ions remains unchanged upon the creation of vacancies.
1984-03-01
British Library Electronic Table of Contents (United Kingdom)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exc...
2010-01-01
International Nuclear Information System (INIS)
The LWR fuel performance analysis computer code, FRAPCON-1, are evaluated to investigate the performance of CANDU fuel elements loaded in Wolsung-1 reactor. The FRAPCON-1 models of neutron flux depression in fuel and of fuel-to-cladding heat transfer are modified, and the validity of fission gas release model for CANDU fuel is evaluated. And the heavy water properties are provided in calculating the heat transfer coefficient between cladding and coolant. By using the modified code, FRAPCON-1-CSK, the sensitivity studies are carried out for Wolsung-1 fuel element design parameters. The performance analysis is also performed for Wolsung-1 fuel elements. The calculated results are discussed in terms of LWR fuel design criteria because of unavailability of CANDU fuel design criteria. (Author).
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
1995-02-01
Analysis of the omnium-g receiver
Energy Technology Data Exchange (ETDEWEB)
A thermal analysis of the Omnium-G receiver is presented and the technique is shown to be generally applicable to solar thermal receivers utilizing a directly heated thermal mass. The thermal loss coefficient, including reradiation losses, is calculated and shown to agree quite well with the experimentally measured thermal loss coefficient. The rate of heat transfer to the working fluid is also analyzed and the analysis is used to show that the Omnium-G receiver is well matched to the water/steam working fluid because the steam outlet temperature is almost the same as the receiver temperature. A general procedure for calculating receiver performance is presented. With this procedure, the energy delivery to any working fluid, the delivered temperature of the working fluid, and the pressure drop through the receiver can be determined. An example of the calculation is also presented.
1980-03-01
Analysis of in-pile heat transfer tests: Final report
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of analysis of selected data from the NRU test series dealing with heatup and reflood heat transfer during postulated PWR LOCA conditions. These tests used nuclear fuel rods and some considered clad ballooning and rupture. Also included was an electrically-heated rod ballooning test, REBEKA-6. The COBRA-TF computer program, renamed PYTHONS, was modified and used for the analytical tool. Modifications included provisions for fuel rod gas flow and pressure, creep deformation and rupture, channel blockage, and blockage heat transfer. Calculated clad temperatures for NRU unpressurized rods show quite good agreement with experimental data. The calculated amount and axial extent of clad ballooning for pressurized rods agrees reasonably well with post-test examinations of the NRU bundles. Time to failure was underpredicted in the MT-3 test as a result of ...
1986-11-01
Energy Technology Data Exchange (ETDEWEB)
A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. ...
2009-06-15
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ...
1992-07-01
International Nuclear Information System (INIS)
To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ...
1992-10-31
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the ...
1984-01-01
Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si
Energy Technology Data Exchange (ETDEWEB)
The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition strongly influences the magnetocaloric ...
2001-01-22
Magnetocaloric and magnetoresistance studies of GdPd_2Si
International Nuclear Information System (INIS)
The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition strongly influences the magnetocaloric effect ...
2001-01-22
British Library Electronic Table of Contents (United Kingdom)
An analysis is presented for the effects of chemical reaction and thermal radiation on hydromagnetic free convection heat and mass transfer for a micropolar fluid via a porous medium bounded by a semi-infinite vertical porous plate in the presence of heat generation. The plate moves with a constant velocity in the longitudinal direction and the free stream velocity follows an exponentially small perturbation law. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micropolar fluid with a suction velocity varying with time. Analytical expressions are computed numerically. Numerical calculations are carried out the purpose of the discussion of the results which are shown on graphs and the effects of the various dimensionless parameters entering into the p...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The application of a method for determining the temperature of an oxygen-replenished air stream heated to 2600 K by a hydrogen burner is reviewed and discussed. The purpose of the measurements is to determine the spatial uniformity of the temperature in the core flow of a ramjet test facility. The technique involves sampling the product gases at the exit of the test section nozzle to infer the makeup of the reactant gases entering the burner. Knowing also the temperature of the inlet gases and assuming the flow is at chemical equilibrium, the adiabatic flame temperature is determined using an industry accepted chemical equilibrium computer code. Local temperature depressions are estimated from heat loss calculations. A description of the method, hardware and procedures is presented, along with local heat loss estimates and uncertainty assessments. The uncertainty of the method is estimated at {+-}31 K, ...
1995-08-01
Heat capacities of the mixtures of ionic liquids with acetonitrile
International Nuclear Information System (INIS)
Isobaric specific heat capacities were measured for {1-hexyl-3-methylimidazolium tetrafluoroborate (HMIMBF4) + acetonitrile (MeCN)} and {1-methyl-3-octylimidazolium tetrafluoroborate (OMIMBF4) + acetonitrile} within the whole range of composition and temperatures from (283.15 to 323.15) K. The excess molar heat capacities were calculated from the experimental results and satisfactorily fitted to Redlich-Kister type polynomials for several selected temperatures. Negative deviations from the additivity of molar heat capacities were observed within the whole composition range of (HMIBMF4 + MeCN) and (OMIMBF4 + MeCN). The results obtained have been interpreted in terms of interactions between ionic liquids and acetonitrile.
2010-02-01
An economic planning tool for geothermal energy projects
Energy Technology Data Exchange (ETDEWEB)
Three geothermal direct heat applications were examined to derive a set of cost estimates from which one could determine the effect of changes in system parameters (temperature, flow, load, etc.) on the cost of heat. For each application, a set of resource characteristics and system inputs were chosen to best represent a site specific baseline condition. The baseline estimated cost of heat was calculated along with other cost estimates representing optimistic and pessimistic conditions, bracketing the range any input variable might reasonably take. Regression equations based upon these cost estimates were developed for each application to quantitatively relate changes in cost to changes in the input variables. These three equations and their accompanying nomographs serve as easily understandable planning tools for direct heat geothermal energy projects.
1980-12-01
Energy Technology Data Exchange (ETDEWEB)
The overall aim is to develope programme modules for a Danish integrated computer system for projecting buildings and to ensure that Danish programmes are compatible with international systems. The programmes to be integrated here were AutoCAD and SCRIBE-models and the simulation programme tsbi3 for the calculation of indoor climate conditions, power demand and energy consumption in buildings. For the calculation of humidity and temperature conditions in constructions a certain amount of integration is carried out with the MATCH programme (Moisture And Temperature calculations for Constructions of Hygroscopic materials). The activities embodied in the pilot projects are described in this working report in addition to the individual computer programmes and prototypes, and examples and diagrams are presented. The programmes included are a geometry programme for the calculation of areas, lengths and ...
1993-03-01
Economic thickness for industrial insulation
Energy Technology Data Exchange (ETDEWEB)
This manual is presented in 8 chapters plus appendices. Chapters 1 and 2 are included as background information. The economic insulation thickness is found using the following chapters: Chapter 3, cost of energy (heat and refrigeration); Chapter 4, cost of insulation, and Chapter 5, economic thickness determination. Each of these chapters contains a worksheet, which provides a step-by-step procedure for solving the problem. Nomographs are included in each section for simplifying the required calculations. For subambient temperature systems, the economic insulation thickness calculated with Chapters 3 to 5 should be compared to the thickness required to prevent condensation (sweating), as calculated with Chapter 6. Chapter 7 presents the procedure for calculating economic insulation for retrofit situations. Sample problems are included in Chapter 8.
1983-01-01
International Nuclear Information System (INIS)
Non-design-basis transition changes in the level fluctuations in the surrounds of a hot steam generator collector for a WWER-440 reactor and the corresponding responses of the temperature fields, strains and stresses are examined. A new approach to the thermal calculation of the horizontal steam generator, which is rapid and affords accurate results, is suggested. An important result of the calculation is the shape of the transition region level and the corresponding distribution of the heat transfer coefficient values. This was used for the calculation of the temperature fields, strain and stress of the hot collector. The stress values obtained were deeply below the yield point of the hot collector material but they get superimposed on the stress from overpressure in the primary and secondary circuits. The obtained fluctuations of the secondary medium level in the surrounds of the hot collector give ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to ...
2006-07-01
Investigation of Heat Transfer in Supercritical Fluids for Application to the Generation IV
Energy Technology Data Exchange (ETDEWEB)
Using a facility named SPHINX, which can accommodate a heat transfer test with CO{sub 2} at supercritical pressure, a series of tests was performed. The test geometries include tubes with the inner diameter of 4.4, 6.32 and 9 mm. a concentric annular passages with 8 x 10 mm, and an eccentric annular passages with 9.5 x 12.5 mm. Based on the test results, heat transfer correlations were developed and compared with the existing correlations. The heat transfer deterioration which may occur at certain conditions of heat and mass flux, were carefully studied and the published criteria were reviewed against our test results. Numerical calculation by using commercial CFD code, Fluent, were performed in order to provide the pre-test information for the heat transfer tests. Various turbulence models were evaluated and reliable models were suggested for each case
2007-08-15
International Nuclear Information System (INIS)
The applicability of the thermal response of an electrically heated simulated rod mostly used in loss-of-coolant-accident (LOCA) experiments to that of a nuclear fuel rod is a concern for the safety evaluation of a reactor. The present analysis describes the characteristics of the thermal response for both electrically heated and nuclear fuel rods during typical reflood conditions for a PWR-LOCA. A model describing the radial temperature field in the rod is developed based on the scheme in HETRAP code by Malang and incorporated into a reflood analysis code, REFLA for that purpose. The calculations applied to the existing reflood tests gave good agreement with experiments, showing the validity of the present model. The analysis has shown that the nuclear fuel rod tends to give a lower clad temperature and a sooner quench time than the electrically heated rod in a typical reflood condition, due to the ...
Design of a closed 4 MW spallation target module with heat removal system for an ADS system
International Nuclear Information System (INIS)
At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the numerical results can be ...
Energy Technology Data Exchange (ETDEWEB)
Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.
1982-04-01
Improvement of FLOWER code and its application in Daya Bay
International Nuclear Information System (INIS)
FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.
International Nuclear Information System (INIS)
When analyzing the loss-of-coolant accidents at VVER reactor NPP the problem of the effect of noncondensable gases on heat transfer in a horizontal steam generator (HSG) is gaining in importance. Based on the RELAP5/MOD3.2 computer code one analyzed the experiments to condense steam-and-gas mixture in a HSG. The calculations are shown to predict satisfactorily duration of steam generator poisoning from noncondensable gas
2005-03-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents a procedure for the calculation of an absorption-refrigeration plant that uses an LiBr/ZnBr{sub 2}/CH{sub 3}OH solution and is driven throughout the year by heat received from a solar pond. The calculations for the solar pond are based on a finite-difference solution of the transient heat conduction differential equation during the year, and the operation of the refrigeration unit is simulated by the use of functions describing the thermodynamic behaviour of the working medium. On the basis of the procedure devised, correlations and nomographs are developed that describe the seasonally optimum operation of the proposed composite system. The nomographs may be employed for a first estimation in the design of such systems. (Author).
1992-07-01
International Nuclear Information System (INIS)
Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the ...
2006-06-15
Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5
Energy Technology Data Exchange (ETDEWEB)
Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. ...
1988-01-01
Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5
International Nuclear Information System (INIS)
Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. The ...
1988-11-04
Energy Technology Data Exchange (ETDEWEB)
An investigation was carried out to determine the significance of a large input of cogeneration units for the electric power generation, next to the input of coal and uranium. Thereto a production plant has been set up to generate heat and electric power. The plant serves as a basis for a number of comparative calculations: basic calculations to investigate the influence of some strategies on the cogeneration input, and sensitivity calculations to determine the influence of a few changes in the starting points. Some variants have been deduced from this plant, which is based on prognosis for the year 2000. By means of the computer calculation program OPINIE (Optimale Inzet en Instelling van Eenheden: Optimal Input and Installation of Units) the minimal variable costs were calculated for different situations. Finally for each considered situation the total annual ...
1987-02-01
Energy Technology Data Exchange (ETDEWEB)
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
1981-09-01
Energy nomographs as a design tool for daylighting
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to inform commercial building designers about an energy analysis tool which can aid them in making appropriate decisions about daylighting. The energy nomographs are an energy design tool which calculate the annual energy consumption of commercial buildings, including lighting, heating, cooling, domestic hot water, fans, pumps, and miscellaneous items. This paper specifically discusses the daylighting aspects of the tool. The calculation procedure is presented with an example to explain how this design tool can be used to make good energy decisions early in the design process.
1984-01-01
A correlation of the acidity and catalytic activity of zeolites
This paper obtains the acidity spectra of modernites and SVK-zeolites from the heats of adsorption of NH/sub 3/ at 300 C and compares the catalytic activity of these zeolites with the cracking of n-octane and the isomerization of o-xylene. It is shown that the calculation of the specific catalytic activity of centers of different strengths by the method of regional rates allows one to predict the activity of the zeolites from the acidity spectra. It follows from the calculation that only the centers of Bronsted acidity are active towards cracking but that the centers of Lewis acidity are also active towards isomerization.
1985-12-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
1984-12-01
Turbulent flow in a channel with transverse rib heat transfer augmentation
Turbulent flow in a 2D channel with repeated rectangular rib roughness was numerically simulated using a low Reynolds number form of the k-epsilon turbulence model. Friction factors and average Stanton numbers were calculated for various pitch to rib height ratios and bulk Reynolds numbers. Comparisons with experiment were generally adequate, with the predictions of friction superior to those for heat transfer. The effect of variable properties for channel flow was investigated, and the results showed a greater effect for friction than for heat transfer. Comparison with experiment yielded no clear conclusions. The turbulence model was also validated for a related problem, that of flow downstream of an abrupt pipe expansion.
1993-04-01
International Nuclear Information System (INIS)
A numerical and experimental investigation is carried out in a solar thermochemical reactor for the thermal dissociation of ZnO at 2000 K using concentrated solar energy. The reactor consists of a cavity-receiver lined with ZnO particles and directly exposed to high-flux irradiation. A transient heat transfer model is formulated to link the rate of radiation, convection, and conduction heat transfer to the reaction kinetics. The radiosity and Monte Carlo methods are applied to obtain the distribution of net radiative fluxes at the internal surfaces of the reactor cavity and at the surface of the ZnO bed. Validation is accomplished in terms of the calculated and measured transient temperature profiles and chemical reaction rates.
2008-04-01
International Nuclear Information System (INIS)
Heat capacities and densities of aqueous MgCl/sub 2/, CaCl/sub 2/, and SrCl/sub 2/ from the accompanying paper are combined with literature data up to 473 K to yield temperature-dependent equations by using the ion-interaction model of Pitzer. These heat capacity equations have been integrated to yield the enthalpy and the Gibbs energy. The enthalpy parameters for 298 K are evaluated in separate calculations using published high-temperature osmotic data as well as heats of dilution, while the Gibbs energy parameters for 298 K are taken from the literature. The range of validity of the final equations is described.
1987-01-01
The lost heat capacity and entropy in the helical magnet MnSi
We report results of measurements and analysis of the heat capacity of MnSi. The measurements included data collection at a magnetic field of 4T, which suppresses strongly the longitudinal spin fluctuations and the phase transition. To analyze the experimental data, calculations of the phonon spectrum and phonon density of states in MnSi were performed. Inelastic neutron scattering with a polycrystalline sample of MnSi was used to validate the computational results. The combination of the experimental and theoretical data turned out to be decisive in revealing some hidden features of the thermal excitations in MnSi. In particular, the analysis of the available data led conclusively to the existence of a negative contribution to the heat capacity and entropy in MnSi at T>Tc, implying that a specific spin ordering process did occur in the paramagnet phase of MnSi.
2011-03-01
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Mixed convection in a rectangular channel (width/height = 2) with bottom-heated and top-cooled sections is studied by laser Doppler anemometry in nitrogen at Ra = 22,200 and Re = 18.75, 36, and 54. At the lower Re values, symmetry breaking is observed in steady but spatially oscillating flows that prevail over a certain distance from the leading edge of the differentially heated section. Further downstream, unsteady flows are found even for Re = 18.75. Numerical models are used to investigate the effects of adiabatic, conducting (with a conductive-convective heat transfer coefficient), and perfectly conducting side walls; channel tilts and Prandtl number dependence. Good agreement between calculations and experiment is obtained for longitudinal convective roll velocities. The transverse velocities are found to be independent of Re.
1992-06-01
Heat transfer augmentation in a rectangular channel with a vee-shaped vortex generator
International Nuclear Information System (INIS)
The unsteady flow and heat transfer are simulated using LES and DNS for a channel with two angled ribs as a vee-shaped vortex generator to augment heat transfer. The vortex generators are attached on the bottom wall of the channel and their angles in respect to the main flow are between 10"o and 30"o. The Prandtl number is 0.71 and the Reynolds numbers based on the inflow velocity and the height of channel are from 200 to 2000. Based on the results of this work, the variations of the Nusselt number, pressure coefficient, bulk temperature, friction factor and Colburn factor with the Reynolds numbers and the incidence angles are provided. The relation between the key parameters of the velocity (friction factor f) and thermal (Colburn factor J) boundary layers is calculated for all cases and their values are compared with the predicted values by the Chilton-Colburn analogy. A comparison between the DNS and LES results is ...
2007-04-01
Drying characteristics and nitrogen loss of biogas digestate during drying process
Energy Technology Data Exchange (ETDEWEB)
The cost of transporting biogas digestate can be decreased by reducing its water content. However, the digestate emits volatile compounds during drying. This study investigated the drying behaviour and the change of digestate composition. Drying took place in a hybrid solar/waste-heat dryer that used solar energy as well as waste heat from a combined heat and power unit (CHP) and the exhaust air of a microturbine. The experiment involved the use of 60 t of liquid digestate. Climatic conditions were measured inside and outside the drying hall. Dry matter (DM) and organic dry matter (ODM) were also measured on a daily basis. In addition, the energy consumption of waste and solar heat were recorded and related to the quantity of dried feedstock. The total nitrogen, ammonium, phosphate, potassium oxide, magnesium oxide and calcium oxide in the digestate were subjected to chemical analysis before and after ...
2010-07-01
A study of the effect of rod-bowing on critical heat flux
International Nuclear Information System (INIS)
An experimental study was carried out to determine the effect of rod-bowing on critical heat flux, using an electrically heated rod cluster. In this experiment, rod-bow was set to occur in the severest subchannel and axially at the middle between the last two spacers, with uniform axial heat flux. The maximum gap between the outer and inner rods was reduced variously to 1.6 mm, 1.00 mm and zero from the nominal value of 2.1 mm. Other experimental conditions were as follows: pressure 7 MPa; mass velocity 640-2600 kg/m"2sec; inlet subcooling 40-560 kJ/kg. Experimental results show only a slight rod-bowing effect, if any, compared with normal spacing, as confirmed by analysis of three-dimensional heat conduction around the rod-bowing area and by the local steam quality deviations calculated by subchannel analyses. (Auth.).
Dimensions and Latent Classes of Episodic Mania-Like Symptoms in Youth: An Empirical Enquiry
British Library Electronic Table of Contents (United Kingdom)
The dramatic increase in diagnostic rates of bipolar disorder in children and adolescents in the USA has led to an intense interest in the phenomenology of the disorder. Here we present data from a newly-developed instrument to assess episodic mania-like symptoms in youth in a large population-based sample (N?=?5326) using parent- and self-report. We found that a substantial proportion of children screened positive for having episodes of ?going high? and were at an increased risk for morbidity and impairment. Using factor analysis, we identified that episodic mania-like symptoms comprised two dimensions: An under-controlled dimension that was associated with significant impairment, and a low-risk exuberant dimension. Using latent class analysis, we identified a small group of children scor...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The thermodynamic characteristics of adsorption (the Henry constant, the heat and entropy of adsorption) of amino acids associates with acetic, trifluoroacetic, nonafluoropentanoic acids and formamide with different values of hydrogen bond lengths and various conformations on a graphitized thermal carbon black (GTCB) were calculated. The experimental results, as the Henry constant, lnK1, and the differences in the molar Gibbs energies, d(DG), obtained by a high performance liquid chromatography (HPLC) on a carbon sorbent Hypercarb, were compared with the values of thermodynamic characteristics of adsorption of the amino acids on the GTCB surface calculated by a molecular-statistical method. A satisfactory correlation was observed between the experimental and calculated values with a coeffi...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Density functional theory calculations were performed to study the effects of different substituents and bridge groups on the heats of formation (HOFs), thermal stability, and detonation properties for a series of diiminotetrazole derivatives. The isodesmic reaction method was employed to calculate the HOFs of the derivatives using total energies obtained from electronic structure calculations. The bond dissociation energies and bond orders for the weakest bonds were analyzed to investigate the thermal stability of the diiminotetrazole derivatives. The detonation velocities and pressures were evaluated by using the semiempirical Kamlet-Jacobs equations, based on the theoretical densities and HOFs. These results provide basic information for the molecular design of novel high-energy density...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments. (orig.) 4 refs.
1997-12-01
International Nuclear Information System (INIS)
Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments. (orig.).
1995-09-10
Adiabatic flame temperature of hydrogen in combination with gaseous fuels
Energy Technology Data Exchange (ETDEWEB)
The equilibrium composition and temperature resulting from the combustion of hydrocarbon fuels in combination with hydrogen have been analytically evaluated. Rich, lean and stoichiometric mixtures have been considered for this purpose. The flame temperature data obtained from computer calculations has been fitted with an equation expressed in terms of calorific value, C/H ratio, air-fuel ratio and heat of dissociation of the fuel mixture. This equation can be used to calculate the flame temperature directly without resorting to the elaborate calculation of species concentration. The results obtained using the equation have been found to have an accuracy of 0.05 to 2.5% for different fuel combinations. (author).
1989-01-01
UAl/sub 2/: Fine structure of the f bands
Energy Technology Data Exchange (ETDEWEB)
The electronic structure of the C15, or cubic-Laves-phase material, UAl/sub 2/ has been calculated using the linearized relativistic augmented-plane-wave method. The anomalous behavior of the electrical resistivity, specific heat, and magnetic susceptibility can be explained by the fine structure of the density of states near the Fermi energy alone, without the necessity of the introduction of drastic spin fluctuations or many-body effects.
1985-08-15
Thermo-hydraulic design of Chinese helium cooled solid breeder blanket for ITER-TBM
International Nuclear Information System (INIS)
To further optimize thermo-hydraulic capability of HCSB-TBM, two different thermo-hydraulic schemes would be proposed and investigated by relevant calculating and simulating of thermo-dynamics in normal and peak heat flux condition. With computational fluid dynamics (CFD) code FLUENT, the actual temperature distribution of key components of HCSB-TBM is simulated. (authors)
2009-06-01
Lattice parameters and thermal expansion of solid ortho-deuterium
Energy Technology Data Exchange (ETDEWEB)
X-ray results on the lattice parameters, molar volume and thermal expansion coefficients of solid ortho-deuterium for the region from 2 K to the melting point are reported. It is found that the thermal expansion of ortho-deuterium crystals, similarly to parahydrogen is essentially anisotropic near the melting temperature. The vacancy density at the triple point is estimated. Some thermodynamic characteristics of ortho-deuterium are calculated and temperature dependences of heat capacity at constant volume, isothermal compressibility and Gruneisen constant are analyzed.
1984-01-01
Ignition and combustion features of biofuels
British Library Electronic Table of Contents (United Kingdom)
This paper presents the results of experimental investigations of the ignition and combustion of plant biofuels (wood particles, date stones) and products of their mechanical and thermal treatment (pellets, charcoal) at temperatures typical of the burning process in nonforced furnaces and fixed-bed and fluidized-bed gas producers. The influence of the furnace heat treatment of a fuel on its inflammation and combustion has been revealed. The results have been compared with the known data on the burning of pellets, brown coals, and anthracites and with the calculation by the classical diffusion-kinetic model.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from ...
1982-01-01
International Nuclear Information System (INIS)
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate estimation of the large (factor of 2) changes in the gamma energy ...
1976-01-01
Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event
International Nuclear Information System (INIS)
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle ...
2001-10-01
Energy Technology Data Exchange (ETDEWEB)
Apparent molar volumes V{sub phi} and apparent molar heat capacities C{sub p,phi} were determined for aqueous solutions of nickel(II) nitrate, copper(II) nitrate, and zinc(II) nitrate at molalities m=(0.01 to 0.5) mol {center_dot} kg{sup -1}, and at the pressure p=0.35 MPa. Solution densities obtained using a vibrating-tube densimeter at T=(278.15 to 368.15) K were used to calculate V{sub phi} values. Heat capacity measurements obtained with a twin fixed-cell, differential-output, power-compensating, temperature-scanning calorimeter at T=(278.15 to 393.15) K were used to calculate values of C{sub p,phi}. Our results were then fitted to functions of m and T and compared to literature values.
2004-05-01
Heat capacity of VT1-0 commercial titanium and VT5 and VT5-1 titanium base alloys at low temperature
International Nuclear Information System (INIS)
The temperature dependences of the heat capacity of commercial titanium VT1-0 and alloys on its base, VT5 and VT5-1, have been derived in the temperature range of 4 to 290 K. For comparison, similar measurements have been conducted on pure titanium and specially prepared solid solutions on its base (Ti+3.7 at.% Al and Ti+0.82 at.% Sn). The measurement accuracy has been sufficient for comparing the results with calculation data. The obtained results are interpreted using the known concepts of the role of the mass of interstitial atoms and changes in the interatomic bond forces. It is shown that the phonon components of the molar heat capacities of solid solutions of Al in titanium have lower values in the entire temperature range, as compared to titanium. The corresponding differences are proportional to the Al concentrations. The lower molar heat capacity in the case of dissolution of Al is due to the ...
1978-01-01
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting ...
Advanced nuclear data for radiation-damage calculations
Energy Technology Data Exchange (ETDEWEB)
Accurate calculations of atomic displacement damage in materials exposed to neutrons require detailed spectra for primary recoil nuclei. Such data are not available from direct experimental measurements. Moreover, they cannot always be computed accurately starting from evaluated nuclear data libraries such as ENDF/B-V that were developed primarily for neutron transport applications, because these libraries lack detailed energy-and-angle distributions for outgoing charged particles. Fortunately, a new generation of nuclear model codes is now available that can be used to fill in the missing spectra. One example is the preequilibrium statistical-model code GNASH. For heating and damage applications, a supplementary code called RECOIL has been developed. RECOIL uses detailed reaction data from GNASH, together with angular distributions based on Kalbach-Mann systematics to compute the energy and angle distributions of recoil nuclei. The ...
1983-01-01
UK PubMed Central (United Kingdom)
The Epstein-Barr virus protein, LMP1, is a functional mimic of the cellular receptor CD40, but signals to B lymphocytes in an amplified and sustained manner compared to CD40. LMP1 contributes...Full Text Available
2009-09-01
Energy Technology Data Exchange (ETDEWEB)
Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was ...
1989-09-01
Energy Technology Data Exchange (ETDEWEB)
Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was ...
1989-09-01
Steady-state film-boiling data in rod-bundle geometry and non-equilibrium correlation assessment
Energy Technology Data Exchange (ETDEWEB)
A series of 22 steady-state, rod bundle, dispersed flow film boiling experiments has been performed in the Thermal-Hydraulic Test Facility (THTF), a pressurized-water loop containing 64 full-length electrically heated rods. Test parameters in the upflow experiments cover a wide range of conditions typical of those which might be encountered during a nuclear reactor loss-of-coolant accident. Local equilibrium fluid conditions were calculated using mass and energy conservation considerations. Experimentally determined heat transfer coefficients were compared to several available film boiling heat transfer correlations: Dougall-Rohsenow, Groeneveld 5.7, Groeneveld-Delorme, Chen, Jones-Zuber, and Yoder-Rohsenow. The Groeneveld 5.7 correlation tended to predict the data better than any other correlation tested. The Dougall-Rohsenow correlation tends to overpredict the data while the Yoder-Rohsenow ...
1982-01-01
Radio Frequency Plasma Applications for Space Propulsion
Energy Technology Data Exchange (ETDEWEB)
Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...
1999-09-13
Energy Technology Data Exchange (ETDEWEB)
The described heat transfer model supplies plausible results for the size distribution of active nucleation spots. For boiling states for which a comparison with measured bubble covering density is possible, that is for low boiling pressures and low heat flux densities, the bubble covering densities calculated by model on the basis of heat transfer measurements agree relatively well with the values observed. (orig.) [Deutsch] Das beschriebene Waermeuebergangsmodell liefert plausible Ergebnisse fuer die Groessenverteilung der aktiven Keimstellen. Fuer die Siedezustaende, fuer die ein Vergleich mit gemessenen Blasenbelegungsdichten moeglich ist, d.h. fuer niedrige Siededruecke und kleine Waermestromdichten, stimmen die aufgrund der Waermeuebergangsmessungen mit dem Modell berechneten Blasenbelegungsdichten verhaeltnismaessig gut mit den beobachteten Werten ueberein. (orig.)
1992-02-15
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
International Nuclear Information System (INIS)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. ...
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. ...
2007-03-15
A hydroxide mixture as working fluid for absorption heat pumps
Energy Technology Data Exchange (ETDEWEB)
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer ...
1996-11-01
Calculation of current-carrying capacity of forced cooled high-voltage cable lines
Energy Technology Data Exchange (ETDEWEB)
The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current ...
1982-01-01
International Nuclear Information System (INIS)
Relative densities and relative massic heat capacities have been measured for aqueous solutions of Y(ClO_4)_3, Yb(ClO_4)_3, Dy(ClO_4)_3, and Sm(ClO_4)_3 at T=(288.15,298.15,313.15, and 328.15) K and p=0.1 MPa. These measurements were made in the concentration range 0.01624#<=#m/(mol#centre dot#kg"-"1)#<=#0.41822 using a Sodev 02D Vibrating Tube Densimeter and a Picker Microflow Calorimeter, respectively. To counter the potential effects of hydrolysis, aqueous solutions of the investigated salts were acidified with perchloric acid. After correcting for the presence of the acid, the measured properties were used to calculate apparent molar volumes and apparent molar heat capacities for solutions of the perchlorate salts in water. The calculated apparent molar properties were modeled at each investigated temperature using Pitzer ion interaction equations to produce estimates of apparent molar volumes ...
2003-05-01
In this paper, the effects of surface mediation on the adsorption isotherm and isosteric heat of adsorption on a graphite surface were investigated, as the surface mediation is known to affect the intermolecular interaction of adsorbed molecules close to the surface. Kim and Steele (Phys. Rev. B 45 (11) (1992) 6226-6233) and others have assumed that the surface mediation is confined only to the first layer. This will be tested in this paper with a combined experimental and Grand Canonical Monte Carlo (GCMC) simulation of adsorption of argon on graphitized thermal carbon black (GTCB) over a range of temperatures (77-95.25K). By matching the simulation results against the experimental data, we have found that the surface mediation is extended up to the fourth layer, rather than only the first as suggested by Kim and Steele, and the extent of this mediation is reduced with distance from the surface. This reinforces the important role of surface on the intermolecular ...
2009-11-14
Boil-off experiments with the EIR-NEPTUN Facility: Analysis and code assessment overview report
International Nuclear Information System (INIS)
The NEPTUN data discussed in this report are from core uncovery (boil-off) experiments designed to investigate the mixture level decrease and the heat up of the fuel rod simulators above the mixture level for conditions simulating core boil-off for a nuclear reactor under small break loss-of-coolant accident conditions. The first series of experiments performed in the NEPTUN test facility consisted of ten boil-off (uncovery) and one adiabatic heat-up tests. In these tests three parameters were varied: rod power, system pressure and initial coolant subcooling. The NEPTUN experiments showed that the external surface thermocouples do not cause a significant cooling influence in the rods to which they are attached under boil-off conditions. The reflooding tests performed later on indicated that the external surface thermocouples have some effect during reflooding for NEPTUN electrically heated rod bundle. Peak cladding ...
International Nuclear Information System (INIS)
Thermodynamic data has been selected for solids and aqueous species of technetium. Equilibrium constants have been calculated in the temperature range 0 to 300 deg C at a pressure of 1 bar for T<100 deg C and at the steam saturated pressure at higher temperatures. For aqueous species, the revised Helgeson-Kirkham-Flowers model is used for temperature extrapolations. The data base contains a large amount of estimated data, and the methods used for these estimations are described in detail. A new equation is presented that allows the estimation of #DELTA#_rCdeg_p_m values for mononuclear hydrolysis reactions. The formation constants for chloro complexes of Tc(V) and Tc(IV), whose existence is well established, have been estimated. The majority of entropy and heat capacity values in the data base have also been estimated, and therefore temperature extrapolations are largely based on estimations. The uncertainties derived from these ...
Thermal hydraulic analysis of nuclear reactors (THEA). THEA summary report
Energy Technology Data Exchange (ETDEWEB)
The project is focused on the thermal hydraulic analyses of nuclear power plants. Specific areas of research have been the modelling of heat transfer in horizontal steam generator in presence of non-condensable gas, and the development of tools for multidimensional two-phase flow simulations. The effect of non-condensable gas on the heat transfer in the horizontal steam generator (SG) has been studied by calculating with APROS the PACTEL experiments NCG-1 (air injection) and NCG-3 (helium injection). The work done for the two-phase flow model development consists of two parts; improving the solution algorithm of porous media code PORFLO, and adding a homogeneous two-phase model to the commercial CFD code Fluent. (orig.)
2004-07-01
The transition of metallic crystals nanostructure into the nanostructure of metallic liquids
International Nuclear Information System (INIS)
The evolution of metallic substance atomic structure is studied on temperature variation including crystal heating up to melting points, a crystal- liquid phase transition and initiation of a high-density liquid specific structure. It is marked that heat induced changes of simple metal structure can be described as changes around a natural elementary cell which is common for both a crystal and a liquid and consists of a central atom and Z_1 atoms of the first coordination sphere. On this basis the vacancy model of melting is verified. Concentrations of melting vacancies are determined by coordination numbers in the form of Z_1/(1+Z_1)"2 which are the same for both a crystal and a natural elementary cell. The size of natural elementary cells is in an agreement with that of the coordination sphere featured in the liquid and phase transition statistical theory. Calculated data are given for a number of metals, Cs, Eu, Ni, V ...
The questions of liquid metal two-phase flow modelling in the FBR core channels
International Nuclear Information System (INIS)
The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
The main purpose of the study on the title subject is to gain insight into the strategic options to optimize energy production from waste processing in the Netherlands in the long term. The developed optimization model will be used by the Dutch Ministry of Public Health, Spatial Planning en Environment (VROM) for scenarios to calculate and determine expectations and uncertainties in the development of waste processing in the Netherlands. Attention is paid to (1) the impact of present and future technology on the costs and energetic efficiency of waste processing, (2) several techniques for the generation of electricity and heat, the production of fuels, and recycling, (3) the impact of scale (capacity) on costs and energetic efficiency of waste processing installations, and (4) the impact of transport and heat distribution. The time frame is the year 2020. 66 refs.
2001-01-01
Oak Ridge Research Reactor. Quarterly report, July, August, and September 1984
Energy Technology Data Exchange (ETDEWEB)
The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.
1985-03-01
Indoor climate seminar; Sisaeilmastoseminaari
Energy Technology Data Exchange (ETDEWEB)
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
1989-12-31
Energy from waste: current progress in Sweden
Energy Technology Data Exchange (ETDEWEB)
Considerable effort worldwide has been put into trying to find the best way to utilise the large amount of energy that we put into our dustbins every day. One of the problems encountered is that the waste collection systems tend to gather together in one place between 400 and 1000 t of the stuff everyday and since it is possible to extract rather more than 2 MW from each tonne, that is a lot of energy for which to find a market. In continental European cities, especially Germany, and Sweden with most of the population living in apartment blocks, and with colder winters than the UK, district heating provides a suitable market. With its milder winters, more diverse housing and cheap gas the UK is not such a fertile ground for district heating. But since the passing of the Energy Act in 1984, there is a steady market in electricity generation with the advantage that the purchase tariffs are published so that income can be accurately ...
1988-11-01
Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K
International Nuclear Information System (INIS)
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
1991-01-01
Effects of the alfven wave spectrum in heating experiments in TCA
International Nuclear Information System (INIS)
Reduction of the metallic impurity concentration in the TCA plasma has enabled us to correlate the observed heating with the calculated position where the rf energy is deposited. In modelling the measured antenna loading due to the presence of Alfven resonance surfaces, and hence inferring the energy deposition profile, both ion cyclotron effects and the toroidal geometry must be considered. In particular, toroidicity couples energy to resonance surfaces that would not be excited in cylindrical geometry. The increase in electron density during a rf pulse changes the positions of these surfaces so that spectrum-related effects may be observed. The appearance of a new surface at the centre of the plasma is seen as a sharp discontinuity on many of the macroscopic parameters, accompanied by evidence of changes in the current density profile. These results, and the predictions of numerical codes, have imposed new constraints on the optimisation of ...
Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces
Energy Technology Data Exchange (ETDEWEB)
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of ...
1981-10-01
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...
2005-07-01
International Nuclear Information System (INIS)
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...
2005-10-02
Thermalhydraulic Characteristics for Wolsung-1 after retubing
International Nuclear Information System (INIS)
The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated
2009-05-01
International Nuclear Information System (INIS)
The temperature dependences of the Grueneisen parameter, heat capacity, bulk modulus and linear thermal expansion coefficient of sixteen III-V zincblende compounds are studied by first-principles response-function calculations. The fundamental relationships among these physical parameters are explored. Negative thermal expansions at lower temperature are found in most of these III-V phases except for the nitrides and boron compounds. By analyzing the cell-volume dependences of the phonon spectrum, it is found that the phases with a negative thermal expansion show a significant acoustic phonon weakening at the X-point in their phonon dispersion, while slight weakening is only seen around the L-point for those boron phases. There is no sign of phonon weakening in the nitrides. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2009-07-01
Steady state temperature profile in a cylinder heated by microwaves
Energy Technology Data Exchange (ETDEWEB)
A new theory has been developed to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii contained in a cavity excited in one of the TM{sub 0n0} modes with n = 1, 2 or 3. Calculations were also performed with a concentric outer cylindrical tube surrounding the rod to investigate hybrid treating. The parametric studies of the total sample center and surface temperatures were performed as a function of the total power transmitted into the cavity. Also, the total hemispherical emissivity was varied at boundaries of the rod, surrounding tube, and cavity walls. The results are discussed in the context of controlling the average rod temperature and the temperature distribution in the rod during microwave processing.
1995-12-31
Nomographs for predicting crown fire initiation in Aleppo pine (Pinus halepensis Mill.) forests
British Library Electronic Table of Contents (United Kingdom)
Nomographs that calculate the threshold values of surface fire parameters which lead to crown fire initiation were created by linking two separate fire behavior models: Van Wagner?s crown fire ignition criteria and Byram?s surface fire model. The nomographs were also based on the existing surface (fuel load, fuel heat content) and canopy (foliar moisture content, live crown base height) fuel models of Aleppo (Pinus halepensis Mill.) pine forests of Mediterranean Greece. The most important fire parameters for crown fire initiation that are calculated by the nomographs are the critical flame length and the forward spread rate of the surface fire. These parameters are readily observable in the field during fires. The nomographs provide a judicious way to assess whether a crown fire is likely ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Total hemispherical emittance was measured for the SP-100 reactor fuel cladding alloy (Nb-l% Zr). Based on a standard test method (ASTM C 835-82), experiments were conducted on a reference sample of oxidized stainless steel and then on a sample of actual cladding. The sample is heated in a vacuum by passing DC current through it until reaching equilibrium. Measurements are made of the electrical power dissipated in the sample and of the surface temperature. Using the Stefan-Boltzmann Law and some key assumptions concerning conductive and radiative heat transfer, the measured quantities are used to calculate emittance. Calculated values for unoxidized cladding range from 0.159 +/- 5.35% at 913 K to 0.200 +/- 4.51% at 1091 K. Highest value measured after onset of visible oxidation was 0.339 +/- 3.92% at 1269 K.... SP-100, Reactor, Emittance, Niobium, Fuel cladding, Emissivity.
1992-12-01
International Nuclear Information System (INIS)
The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents and daughters) is ...
2009-05-27
Development and validation of steam generator models for thermal performance monitoring
International Nuclear Information System (INIS)
The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. ...
2003-04-20
International Nuclear Information System (INIS)
Isobaric specific heat capacities were measured for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol within the temperature range from (284 to 353) K, and for 2-methyl-2-butanol in the (284 to 368) K temperature interval by means of a differential scanning calorimeter. The excess molar heat capacities were calculated from the experimental results. For the temperature range from (284 to 287) K, the excess molar heat capacity is S-shaped with negative values in the 2-methyl-2-butanol rich region and with small negative values at low alcohol concentrations at temperatures from (295 to 353) K. The excess molar heat capacities are positive for all compositions under test at temperatures from (288 to 294) K. The results are explained in terms of the influence of the molecular size and configuration of the alkanols on their self-association capability and of the change in ...
2009-03-01
International Nuclear Information System (INIS)
In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat ...
1983-10-14
3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4
International Nuclear Information System (INIS)
This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the charcoal and heat is ...
2006-11-13
International Nuclear Information System (INIS)
The molar heat capacities (Cp,m) of a series of synthetic forsterite (Fo)-fayalite (Fa), (Mg2SiO4+Fe2SiO4), olivines have been measured between 5K and 300K on milligram-sized samples with the Physical Properties Measurement System (Quantum Design(R)). Sharp, ?-type heat capacity anomalies are observed in the Fe-rich compositions fayalite, Fo10Fa90, Fo20Fa80, Fo30Fa70, and Fo40Fa60. The corresponding Neel temperatures TN decrease linearly from 64.5K in fayalite to 32.8K in Fo40Fa60 following the relationship TN=79.02.xFa-14.07. Fo50Fa50 and Mg-richer olivines show weak broad features in the heat capacity data around 15K to 20K that decrease in magnitude with increasing forsterite content. In order to derive and separate molar electronic, magnetic and vibrational heat capacity contributions, Cel,m, Cmag,m, and Cvib,m from the experimental heat capacities (Ctot,m), we used a ...
2007-06-01
Thermodynamics of potassium diclofenac salt aqueous solutions at various temperatures
British Library Electronic Table of Contents (United Kingdom)
Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A simple theory for predicting the convective energy loss from side-facing cavity receivers in windless environments has been developed. The approach used is to determine the velocity distribution of the incoming air in the aperture plane (and thereby the rate of mass entrainment); and then to estimate the bulk temperature of the heated emerging air. The convective loss is then calculated from an energy balance. To illustrate this theory, numerical results applicable to the 2.15 meter cubic cavity being tested in the laboratory are provided.
1981-01-01
Natural convection cooling of circumferentially finned transport casks
International Nuclear Information System (INIS)
It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.
1983-12-01
International Nuclear Information System (INIS)
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
1985-10-22
Ground temperatures surrounding a molten fuel pool
International Nuclear Information System (INIS)
In the analysis of the consequences of a hypothetical meltdown accident in an LMFBR, it is important to estimate the final location of the molten fuel pool in the concrete and ground underlying the reactor vessel. The GROWS program and the AYER program have been developed to calculate the final location of the molten fuel pool as the culmination of the transient analysis of this unusual Stefan problem but these programs require extensive computational resources. The solution is provided to the concrete and ground temperatures surrounding the stationary fuel pool and the related heat flux from the pool to the ground surface outside the containment building. This solution can be used to estimate the final location of the fuel pool and to check the end results of the sophisticated programs.
1977-06-01
Design parameters for tube cavity receivers in solar power plants
Energy Technology Data Exchange (ETDEWEB)
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
1981-01-01
Conjugate parallel-flowing free and forced convection boundary layers on vertical wall sides
Energy Technology Data Exchange (ETDEWEB)
The paper describes an analytical study of two parallel-flowing boundary layers of free and forced convection modes on the facing sides of a vertical thin wall. The two layers are analyzed separately within the framework of boundary layer theory, and coupled by the matching conditions at wall. Numerical data are obtained for a wide range of a dimensionless conjugation parameter {zeta} relating the heat transfer effectiveness of two convection modes. Based on these data, an expression for calculating the conjugate mean Nusselt number as a function of {zeta}-parameter is found by means of a curve-fitting method. (orig.)
2003-02-01
Energy Technology Data Exchange (ETDEWEB)
In an adiabatic low-pressure calorimeter, the temperature dependence of the standard molar heat capacity of paramagnetic dicarbonyl rhodium complex with o-semiquinone (CO){sub 2}Rh(SQ) has been determined in the range from T=(6 to 355)K mainly with an accuracy of about 0.3%. Over the ranges from T=(205 to 234) K, T=(266 to 315)K and T=(316 to 345)K physical transformations have been revealed and their enthalpies and entropies have been estimated. The experimental data were used to calculate the thermodynamic functions C{sub p,m}{sup o}/R,{delta}{sub 0}{sup T}H{sub m}{sup o}/(R.K),{delta}{sub 0}{sup T}S{sub m}{sup o}/R and {phi}{sub m}{sup o}={delta}{sub 0}{sup T}S{sub m}{sup o}-{delta}{sub 0}{sup T}H{sub m}{sup o}/T (where R is the universal gas constant) between T=(0 and 355)K. The fractal dimension D in the heat capacity function of the fractal variant of Debye heat capacity theory has been evaluated.
2006-06-15
International Nuclear Information System (INIS)
Experimental and theoretical work have been carried out to find out the effects of heat transfer augmentation on two-phase flow instabilities in a single channel system. The effect of mass flow rate, heat input and inlet subcooling on the system behavior is studied using Freon-11 as the test fluid and six different heater surfaces are tested at various experimental conditions. Experimental evaluation is done using the steady-state pressure drop versus mass flow rate curves along with the curves of additional inlet pressure drop required to stabilize the system during the oscillations, and tables generated using the experimental data. Homogeneous equilibrium flow model and finite differences are used in theoretical analysis. An empirical relationship is obtained to calculate the pressure drop across the exit restriction. Characteristic equation for the system is found by linearizing the dynamic equations of the overall ...
1985-11-01
Energy Technology Data Exchange (ETDEWEB)
Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using HCEDs of the type tested. (author)
2006-09-15
Heat capacities between 1.5 and 16 K and superconductivity of V/H and Nb/H alloys
International Nuclear Information System (INIS)
Molar heat capacities have been measured for VHsub(n) and NbHsub(n) with n up to 1.93 at temperatures between 1.5 and 16 K. The height of the peak in plots of the electronic specific heat, indicating superconductivity, diminishes with increasing hydrogen content in the #alpha# + #beta# two-phase region, and can be taken as a measure of the fractional amount of #alpha#-phase present (lever-rule). In NbHsub(n) accordingly, the two-phase region presumably extends up to n = approximately 0.9 at helium temperatures. No hydride phase, including VH_2 and NbH_2, showed superconductivity above 1.5 K. The measured #gamma#-coefficients of the V/H-alloys agree with APW band-structure calculations for V metal in the range 5 =< nsub(e) =< 7 of band electron concentration. They coincide with the #gamma#-coefficients of V/Cr-alloys reported in the literature. Hence VHsub(n) represents another example of the 'shifting bands' concept ...
1977-05-01
Energy Technology Data Exchange (ETDEWEB)
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to collect basic data for ...
1999-12-05
International Nuclear Information System (INIS)
The static thermophysical properties of the molten salt system like LiF-NaF-BeF_2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 0.15LiF-0.58NaF-0.27BeF_2, over the temperature range from 873.15K to 1073.15K at one atmosphere pressure, is described by using modified Peng-Robinson equation. The density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermophysical properties such as the enthalpy, entropy and heat capacity at constant pressure are evaluated by the fugacity coefficient and residual function methods respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and heat capacity evaluated by such two ...
2008-03-01
International Nuclear Information System (INIS)
The static thermodynamic properties of the molten salt system like LiF-NaF-BeF_2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 15%LiF-58%NaF-27%BeF_2, over the temperature range of 873.15K to 1073.15K at one atmosphere pressure, is described using Peng-Robinson equation modified by us. And the density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermodynamic properties such as the enthalpy, entropy and heat capacity at constant pressure are estimated by the residual function method and the fugacity coefficient method respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and heat capacity evaluated by such ...
2007-04-22
The static thermophysical properties of the molten salt system like LiF-NaF-BeF2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 0.15LiF-0.58NaF-0.27BeF2, over the temperature range from 873.15K to 1073.15K at one atmosphere pressure, is described by using modified Peng-Robinson equation. The density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermophysical properties such as the enthalpy, entropy and heat capacity at constant pressure are evaluated by the fugacity coefficient and residual function methods respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and heat capacity evaluated by such two ...
2008-01-01
Estimation of CHF ratio at various power levels in TAPP-3 and 4 reactors
International Nuclear Information System (INIS)
TAPP-3 and 4 are the 540 MWe PHWRs having horizontal fuel channel. At normal 100% FP operation there is no boiling in the channel. However, when the power increases due to any transient, the boiling may start in the channel. The main application for critical heat flux (CHP) prediction is to set the operating power with a comfortable margin to avoid CHF occurrence. This margin of CHF can be expressed in terms of minimum critical heat flux ratio (MCHFR), which is the ratio of CHF to local heat flux for the same pressure, mass flux and quality. The CHF depends on power, coolant flow rate as well as coolant condition in the channel. As the power increases the flow reduces in the channel and cooling is degraded. The thermal hydraulic code is developed for present analysis. The output of analysis are CHF prediction quality calculation at axial locations of the maximum rated channel at various power levels and ...
2005-12-01
International Nuclear Information System (INIS)
A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating conditions. This is ...
Conceptual Design for BOP of the Sodium-Cooled Fast Reactor
International Nuclear Information System (INIS)
The heavy dependence on nuclear power eventually raise the issues of an efficient utilization of uranium resources, which Korea presently imports from abroad, end of a spent fuel storage. From the viewpoint that sodium-cooled fast Reactors (SFRs) have the potential of an enhanced safety by utilizing inherent safety characteristics, trans-uranics (TRU) reduction and resolving the spent fuel storage problems through a proliferation-resistant actinide recycling. SFRs are sure to be most promising nuclear power operation. The Korea Atomic Energy Research Institute (KAERI) has been developing SFR design technologies since 1997. And nowadays, the preliminary heat balance of the demonstration SFR is calculated. However, in order to verify design condition of the NSSS, it is necessary to set the heat balance and the conceptual design for BOP of the SFR as a part of the SFR design technique development business. Moreover, in order ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the ...
1992-10-01
A simplified two step thermal analysis method for Wolsung (CANDU) spent fuel dry storage canister
A simplified two step thermal analysis method has been develop to evaluate (1) the mean temperature of the CANDU fuel bundles within a fuel basket in a given spent fuel dry storage canister by HEATING5 code with additional input data and heat transfer correlations in the step-1 analysis and (2) the maximum fuel rod temperature within a CANDU 37-element fuel bundle by MAXROT code developed here for step-2 analysis. In addition, the results of sample analysis is performed to examine the parametric effects of the site-specific ambient conditions on the maximum fuel temperature within a canister are presented. The comparison between the results of step-1 analysis and the mock-up test, in particular, is quite satisfactory. In essence, the two-step thermal analysis method proposed here is a code package that used the HEATING5 and MAXROT codes, respectively, for step-1 and step-2 calculations in series.
1993-03-01
A simplified two step thermal analysis method for Wolsung (CANDU) spent fuel dry storage canister
International Nuclear Information System (INIS)
A simplified two step thermal analysis method has been develop to evaluate (1) the mean temperature of the CANDU fuel bundles within a fuel basket in a given spent fuel dry storage canister by HEATING5 code with additional input data and heat transfer correlations in the step-1 analysis and (2) the maximum fuel rod temperature within a CANDU 37-element fuel bundle by MAXROT code developed here for step-2 analysis. In addition, the results of sample analysis is performed to examine the parametric effects of the site-specific ambient conditions on the maximum fuel temperature within a canister are presented. The comparison between the results of step-1 analysis and the mock-up test, in particular, is quite satisfactory. In essence, the two-step thermal analysis method proposed here is a code package that used the HEATING5 and MAXROT codes, respectively, for step-1 and step-2 calculations in series.
1993-01-01
International Nuclear Information System (INIS)
Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test ...
2001-03-20
International Nuclear Information System (INIS)
We have measured the densities at temperatures T = (278.15 to 363.15) K and heat capacities at T = (278.15 to 393.15) K of aqueous solutions of 18-crown-6 and of (18-crown-6 + KCl) at molalities m = (0.02 to 0.3) mol . kg"-"1 and at the pressure 0.35 MPa. We have calculated apparent molar volumes V_#phi# and apparent molar heat capacities C_p_,_#phi# for 18-crown-6(aq), and we have applied Young's Rule and have accounted for chemical speciation and relaxation effects to resolve V_#phi# and C_p_,_#phi# for the (18-crown-6: K"+,Cl"-)(aq) complex in the mixture. We have also calculated estimates of the change in volume #DELTA#_rV_m, the change in heat capacity #DELTA#_rC_p_,_m, the change in enthalpy #DELTA#_rH_m, and the equilibrium quotient log Q for formation of the complex at T = (278.15 to 393.15) K and m = (0 to 0.3) mol . kg"-"1.
2004-12-01
Simplified methods in the estimation of the K-value of insulated cargo holds on ships
Energy Technology Data Exchange (ETDEWEB)
The problem of buried steelwork in cargo hold insulation has been investigated by several using empirical methods. These efforts have resulted in correction factors that serve as a useful aid in the complex task of estimating the K-value of a ship`s cargo holds for the correct dimensioning of the refrigeration plant. Today, the advent of the digital computer has established numerical methods of analysis as a common working tool among practicing engineers. For estimating the flow in cases of buried steelwork that cannot be handled by correction factors, this is an effective approach. This study is an analytical/numerical investigation of the effect that buried steelworks have on the heat leakage across cargo hold walls. It aims at providing enlightenment on the physical significance of the parameters influencing the problem and developing practically simple methods for predicting the heat leakage across the hold walls. The study is set in the ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral ...
1996-03-01
Investigation of thermohydraulic parameters during natural convection cooling of TRIGA reactor
International Nuclear Information System (INIS)
Important steady-state thermohydraulic parameters of the TRIGA research reactor operating under natural convection mode of coolant flow were investigated using NCTRIGA computer code. Neutronic parameters used in preparing the input of NCTRIGA were taken from the analysis performed by 3-D Monte Carlo code MCNP4C. Benchmarking of the NCTRIGA calculated results were performed against the experimental data measured by the thermocouples in the instrumented fuel element (IFE) during the steady state operation of the reactor under natural convection mode of coolant flow. Various thermohydraulic parameters like the coolant velocity, flow rate and mass flow rate were generated for the hot channel as well as for the two channels comprising instrumented fuels. Calculated peak fuel temperatures at different power levels were compared with the measured values and also with the calculations performed by PARET code. Axial temperature ...
2006-09-01
Hidden Markov Mixture Autoregressive Models: Stability and Moments
This paper introduces a new parsimonious structure for mixture of autoregressive models. the weighting coefficients are determined through latent random variables, following a hidden Markov model. We propose a dynamic programming algorithm for the application of forecasting. We also derive the limiting behavior of unconditional first moment of the process and an appropriate upper bound for the limiting value of the variance. This can be considered as long run behavior of the process. Finally we show convergence and stability of the second moment. Further, we illustrate the efficacy of the proposed model by simulation and forecasting.
2011-01-01
International Nuclear Information System (INIS)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low ...
Techno-economic assessment of anaerobic digestion systems for agri-food wastes
Energy Technology Data Exchange (ETDEWEB)
Activities in British Columbia's Fraser Valley generate an estimated 3 million tones of agriculture and food wastes annually, of which 85 per cent are readily available for anaerobic digestion. The potential for energy generation from biogas through anaerobic digestion is approximately 30 MW. On-farm manure-based systems represent the most likely scenario for the development of anaerobic digestion in British Columbia in the near future. Off-farm food processing wastes may be an alternative option to large centralized industrial complexes. Odour control, pathogen reduction, improved water quality, reduced greenhouse gas emissions and reduced landfill usage are among the environmental benefits of anaerobic digestion. The economical benefits include power and heat generation, biogas upgrading, and further processing of the residues to produce compost or animal bedding. This paper described a newly developed anaerobic digestion (AD) ...
2010-07-01
International Nuclear Information System (INIS)
We provide a numerically efficient procedure to perform LDA+Hubbard I calculations including self-consistency over the charge density in the FP-LAPW basis. The method is applied to Pu, Am, and PuAm and PuCe alloys. Our results for valence photoemission spectra (PES) agree with experimental data and with previous LDA+DMFT calculations. Analysis of the J=5/2 and J=7/2 contributions to the f-occupation supports the intermediate-coupling picture of f-states in heavy actinides. The electronic specific heat coefficient is calculated for PuAm and PuCe alloys in reasonable agreement with recent experiments. We show that Pu atoms keep their mixed-valence character in these alloys. Next, we study electronic and spectral properties of Pu-based superconductor PuCoGa_5 and obtain good agreement with experimental PES. Finally, we analyze surface effects. In Pu monolayer, we find substantial modification of PES due to ...
2010-03-21
Energy Technology Data Exchange (ETDEWEB)
Three dimensional computational fluid dynamic (CFD) calculations of a typical prismatic very high temperature gas-cooled reactor (VHTR) were conducted to investigate the influence of gap geometry on flow and temperature distributions in the reactor core using commercial CFD code FLUENT. Parametric calculations changing the gap width in a whole core length model of fuel and reflector columns were performed. The simulations show the effects of core by-pass flows in the heated core region by comparing results for several gap widths including zero gap width. The calculation results underline the importance of considering inter-column gap width for the evaluation of maximum fuel temperatures and temperature gradients in fuel blocks. In addition, it is shown that temperatures of core outlet flow from gaps and channels are strongly affected by the gap width of by-pass flow in the reactor core.
2009-09-01
International Nuclear Information System (INIS)
The Department of Nuclear Engineering and Fluid Mechanics in the University of the Basque Country (UPV-EHU), has done calculations for the proposed benchmark problem, in the frame of the 11th international meeting of the IAHR working group on advanced nuclear reactors thermal-hydraulics (Obninsk-Russian Federation, 5-9 July 2004). The purpose of the benchmark is to compare experimental and analytical results of some experiments carried out in the State Scientific Center of Russian Federation 'Institute of Physics and Power Engineering' (SSC RF IPPE). These experiments were held to research the cooling of pin bundles by liquid metals in reference to the core of Nuclear Reactors such as BREST. The analytical results have been done with the Computational Fluid Dynamics (CFD) code FLUENT. Temperature and velocity fields are the main variables considered for the comparison, and some assumptions has been made in order to simplify a complicate geometry with grids and ...
2004-07-05
Energy Technology Data Exchange (ETDEWEB)
To propose a new design concept of a nuclear reactor used in the space, research has been conducted on the conceptual design of a new nuclear reactor on the basis of the following three main concepts: (1) Thermionic generation by thermionic fuel elements (TFE), (2) reactivity control by rotary reflector, and (3) reactor cooling by liquid metal. The outcomes of the research are: (1) A calculation algorithm was derived for obtaining convergent conditions by repeating nuclear characteristic calculation and thermal flow characteristic calculation for the space nuclear reactor. (2) Use of this algorithm and the parametric study established that a space nuclear reactor using 97% enriched uranium nitride as the fuel and lithium as the coolant and having a core with a radius of about 25 cm, a height of about 50 cm and a generation efficiency of about 7% can probably be operated continuously for at least more than ten years at 100 ...
1998-01-01
The feasibility study of hot cell decontamination by the PFC spray method
International Nuclear Information System (INIS)
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various exergoeconomic performance parameters are ...
2010-11-15
International Nuclear Information System (INIS)
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various exergoeconomic performance parameters are ...
2010-11-01
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A ...
1989-10-01
Final technical report for ''Frontiers in Plasma Kinetic Theory''
International Nuclear Information System (INIS)
This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field approximation, one neglects turbulent motions of field lines, and calculates the diffusion coefficient ...
2007-02-01
Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.
A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...
2004-01-01
Development of the Precarbon process
The Precarbon process has been developed jointly by the Bergbauforschung Institute and the Federal German company, Didier. The characteristic feature of the process is the combination of two-stage coal heating in pipe dryers to 200/sup 0/C and its smokeless charging to the coke ovens by means of a Redler conveyor passing over the coke oven battery. Calculations have shown that the use of preheated coal can be justified economically in three cases: (1) To increase coke oven battery outputs. When using standard coals the battery throughput increase of approximately 45% due to coal preheating reduces costs for coking in comparison with wet coal coking, which would require larger coke ovens. (2) To improve coke quality. Use of preheated coal produces a blast furnace coke of the required quality from charges containing increased weakly-coking coal contents. 3. To increase output from coke oven batteries being rebuilt. A recent development of the ...
1980-01-01
Large Eddy Simulation for Heat Transfer Prediction in a Gas ...
... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...
2007-03-30
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in ...
2006-07-15
International Nuclear Information System (INIS)
The COSA II (computer codes for salt) benchmark problem has been pursued with the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) program code. With the use of this, the code should be validated by means of experimental data and the ability to reproduce real-life calculation results of the KfK (Kernforschungszentrum Karlsruhe/Nuclear Research Center in Karlsruhe) should be proven. A successful validation of the code then forms the foundation stone for the ability to use different calculation problems in the final (ultimate) storage. This also accompanies the consequent reaction of replacing the STEALTH (Solids and Thermal Hydraulics Code for EPRI Adapted from LAGRANGE TOODY and HEMP) program which has a number of program-specific weaknesses compared to the ADINA computer code. In order to reproduce the approximate values from the KfK, the same values have been used. Differences were evident in the discretion and the selection of the ...
Emergency ampacities of direct buried three phase underground cable systems
Energy Technology Data Exchange (ETDEWEB)
A thermal model is formulated for the determination of the emergency transient ampacities of a three phase, horizontally spaced underground cable system. The model is based on a finite difference heat transfer analysis and the principle of superposition which permits the summation of the temperature rise of individual heat sources to eventually provide for the temperature rise of a multiple cable system. The thermal model is transformed into a complex computer program that is capable of calculating the real time cable temperature for any change in conductor current. The program is used to calculate the response of conductor temperatures caused by both ramp and step changes in currents for four conductor sizes between 4/0 and 1500 kcmil. The amount of time to reach conductor temperatures of 100/sup 0/C and 120/sup 0/C from a steady conductor temperature of 75/sup 0/C is calculated ...
1983-07-01
Electronic instabilities and the martensitic transition in A-15 compounds
International Nuclear Information System (INIS)
The structural transition and anomalous properties of the high temperature A-15 superconductors have been investigated from two different standpoints. The first is a Landau theory based on Gorkov's physical model of a Peierls-like charge density wave (CDW) transition involving electronic CDW order parameters coupled to phonon coordinates. Pretransition elastic anomalies, softening of the [1 anti 10] transverse ([1 anti 10] polarized) phonon, sublattice distortions, variation of transition temperature with stress and alloying and other effects have been accurately predicted, and a detailed comparison is made with experimental results. Central peaks in neutron scattering are shown to be non-dynamic in nature and no pretransition forbidden (300) reflection is predicted. The GAMMA_1_2 optic mode does not go soft at the transition, though its frequency is expected to be temperature dependent right up to room temperature. A tight binding, two (3-D) band model of the A-15 compounds, using ...
Energy Technology Data Exchange (ETDEWEB)
In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission products to deduce fission-product yields. Spectral decomposition ...
1997-05-01
The use of supplementary firing in an externally-fired combined cycle power plant
Energy Technology Data Exchange (ETDEWEB)
The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heat exchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine avoids hot gas clean-up and turbine blade corrosion by coal ash. ...
1997-12-31
A study of passive and inherent safety design concepts for advanced light= water reactors
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of condensation heat transfer and effect of ...
1997-07-01
International Nuclear Information System (INIS)
Based on the occurrence of a number of plant incidents during low power and shutdown operating conditions, the Nuclear Regulatory Commission (NRC) has initiated several programs to better quantify risk during these periods. One specific issue of interest is the loss of residual heat removal (RHR) under reduced coolant inventory conditions. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-3 experimental facility at Siemens-KWU to supply applicable data. Recently, an effort has been undertaken at the Idaho National Engineering Laboratory (INEL) to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following loss of vital AC power and consequent loss of the RHR system during reduced inventory operation. The thermal-hydraulic response of a nuclear steam supply system (NSSS) with a closed reactor coolant system (RCS) to loss of residual ...
1991-10-01
Ultra-thin {sup 242m}Am fuel elements in nuclear reactors
Energy Technology Data Exchange (ETDEWEB)
There is a growing interest in using {sup 242m}Am as a nuclear fuel. The advantages of {sup 242m}Am as a nuclear fuel derive from the fact that {sup 242m}Am has the highest thermal fission cross section. The thermal capture cross section is relatively low and the number of neutrons per thermal fission is high. These nuclear properties make it possible to obtain nuclear criticality with ultra-thin fuel elements. The possibility of having ultra-thin fuel elements enables the use of these fission products directly, without the necessity of converting their energy to heat, as is done in conventional reactors. There are three options of using such highly energetic and highly ionized fission products. - Using the fission products themselves for ionic propulsion. - Using the fission products in an MHD generator, in order to obtain electricity directly. - Using the fission products to heat a gas up to a high temperature for propulsion purposes. In this ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
In the present work temperature dependences of heat capacity of carbosilane dendrimers with butyl terminal groups of the third and the fourth generations as well as of the fifth and the sixth generations have been determined first in the range from 6 to 340K and between 6 and 600K, respectively, by precision adiabatic vacuum and dynamic calorimetry. In the above temperature ranges the physical transformations have been detected and their thermodynamic characteristics have been estimated and analyzed. The experimental data were used to calculate standard thermodynamic functions, namely the heat capacity C{sub p}{sup o}(T), enthalpy H{sup o}(T)-H{sup o}(0), entropy S{sup o}(T)-S{sup o}(0) and Gibbs function G{sup o}(T)-H{sup o}(T), for the range from T->0 to (340-600)K. Linear dependences of changing the corresponding thermodynamic functions of the dendrimers on their molecular weight and the number of butyl groups on ...
2006-01-15
Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying out the base of the deposit. The pore to ...
1984-01-01
Powdering characteristics of thin film evaporator, 1. Drying and powdering of solution
Energy Technology Data Exchange (ETDEWEB)
Vertical thin film evaporators have been used to concentrate and dry solutions because their rotating swing blades prevent scale from being deposited on the heated surfaces. Powdering capacity of the vertical thin film evaporator was examined experimentally for drying applications of radioactive liquid waste generated from nuclear power plants. As a result, it was found that the powdering capacity increased with the blade rotation, changing significantly in the low ratational region and scarcely in the high rotational region. The powdering capacity in the high rotational region was restricted by the lack of heat flux which was theoretically evaluated for the concentrating process. As the critical factor in the low rotational region was not clear, a visual test apparatus was made to observe flow patterns in the evaporator, and a powdering model was obtained. This model showed that powdering process was obstructed when the liquid film lost its ...
1983-01-01
Powdering characteristics of thin film evaporator, 1
International Nuclear Information System (INIS)
Vertical thin film evaporators have been used to concentrate and dry solutions because their rotating swing blades prevent scale from being deposited on the heated surfaces. Powdering capacity of the vertical thin film evaporator was examined experimentally for drying applications of radioactive liquid waste generated from nuclear power plants. As a result, it was found that the powdering capacity increased with the blade rotation, changing significantly in the low ratational region and scarcely in the high rotational region. The powdering capacity in the high rotational region was restricted by the lack of heat flux which was theoretically evaluated for the concentrating process. As the critical factor in the low rotational region was not clear, a visual test apparatus was made to observe flow patterns in the evaporator, and a powdering model was obtained. This model showed that powdering process was obstructed when the liquid film lost its ...
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K
Energy Technology Data Exchange (ETDEWEB)
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al{sub 2}O{sub 3} {times} H{sub 2}O), which dehydrated to alumina (Al{sub 2}O{sub 3}) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
1991-02-01
Coriolis effect on thermal convection in a couple-stress fluid-saturated rotating rigid porous layer
Energy Technology Data Exchange (ETDEWEB)
Both linear and weakly nonlinear stability analyses are performed to study thermal convection in a rotating couple-stress fluid-saturated rigid porous layer. In the case of linear stability analysis, conditions for the occurrence of possible bifurcations are obtained. It is shown that Hopf bifurcation is possible due to Coriolis force, and it occurs at a lower value of the Rayleigh number at which the simple bifurcation occurs. In contrast to the nonrotating case, it is found that the couple-stress parameter plays a dual role in deciding the stability characteristics of the system, depending on the strength of rotation. Nonlinear stability analysis is carried out by constructing a set of coupled nonlinear ordinary differential equations using truncated representation of Fourier series. Sub-critical finite amplitude steady motions occur depending on the choice of physical parameters but at higher rotation rates oscillatory convection is found to be the preferred mode of instability. ...
2011-04-15
Energy Technology Data Exchange (ETDEWEB)
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements ...
1981-10-01
A comprehensive approach to cooling tower design
Energy Technology Data Exchange (ETDEWEB)
In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow fields are presented for different distances ...
2001-06-01
Thermal model and thermodynamic performance of molten salt cavity receiver
British Library Electronic Table of Contents (United Kingdom)
The design of a global steady-state thermal model of a 100kWt molten salt cavity receiver was developed as part of the key project of the Ministry of Science and Technology of People's Republic of China (MOST). In the design process, the following factors were analyzed: receiver area, heat loss (convective, emissive, reflective and conductive), number of tubes in the receiver panel, tube diameter and receiver surface temperature. The model was also used to calculate the receiver performance of the Sandia National Laboratories' molten salt electric experiment (MSEE). In addition, the thermal performance of the designed molten salt cavity receiver is presented for a fixed outlet flow rate and a fixed output temperature.
2010-01-01
Synthesis and investigation of tungsten-phosphorus catalysts
Energy Technology Data Exchange (ETDEWEB)
The authors present the results of their investigation of the effect of phosphorus compounds on the activity of tungsten-containing catalysts in the oxidation of ethane. They investigated tungsten-phosphorus catalysts with different phosphorus concentrations (calculated on the basis of P/sub 2/O/sub 5/). The catalysts were prepared by heat decomposition of the starting compounds at 750/sup 0/C for 4 h. As their starting compounds, they used two types of materials: heteropoly acids mixtures of monosubstituted ammonium phosphoric and tungstic acids. The specific surface area of the catalysts was determined using the nitrogen desorption method. The x-ray phase analysis was carried out using a DRON-1.5 diffractometer. The catalytic activity was determined using the impulse method in a reactor with a vibrofluidized catalyst layer.
1988-11-10
Study on cold startability and mixture formation of high-percentage methanol blends
Energy Technology Data Exchange (ETDEWEB)
Using gasoline as an example of additives for cold start improvement, fuel vapor composition of methanol-gasoline mixtures, fuel evaporation rate in consideration of temperature drop due to heat of fuel evaporation, air fuel ratio, stoichiometric air fuel ratio and excess air ratio of fuel vapor were calculated. The mixture formation of methanol-gasoline mixtures at low temperature in otto cycle engines was studied. Van Laar's empirical formula was used to estimate the partial pressure of high-percentage methanol blends. It was found that the most part of fuel vapor is occupied by gasoline, even when a small amount of gasoline is added to methanol resulting to an extremely small excess air ratio. It is obvious that this vapor pressure adjustment using gasoline is the dominant factor for improvement in cold startability. (10 figs, 1 tab, 10 refs)
1988-05-31
Structural and electronic properties of the A-15 compounds Nb_3Rh and Nb_3Ir
International Nuclear Information System (INIS)
The structural and electronic properties of the A-15 compounds Nb_3Rh and Nb_3Ir were studied by means of escalar relativistic full-potential linearized augmented-plane wave (FP-LAPW) calculations with generalized gradient corrections. An investigation of the band structure of the hypothetical Nb_3Nb compound was also performed at the theoretical equilibrium lattice constant to ascertain the contribution of the nontransition elements on the B site in these A_3B-type compounds. Band structures and total densities of states were obtained. A rough estimate of the electron-phonon coupling parameter #lambda# as well as of the electronic specific-heat coefficient #gamma# were obtained for both Nb_3Rh and Nb_3Nb, which confirms that this latter is a low-temperature superconductor with T_c - 10K.
2007-04-30
Solar thermophotovoltaic (STPV) system with thermal energy storage
Energy Technology Data Exchange (ETDEWEB)
A solar thermophotovoltaic (STPV) system has both terrestrial and space applications because thermal energy storage can be utilized. Excellent properties (heat of fusion=1800 j/gm and melting temperature=1680 K) make silicon the ideal thermal storage material for an STPV system. Using a one dimensional model with tapering of the silicon storage material, it was found that several hours of running time with modest lengths ({approximately}15 cm) of silicon are possible. Calculated steady-state efficiencies for an STPV system using an Er-YAG selective emitter and ideal photovoltaic (PV) cell model are in the range of 15{percent}{endash}17{percent}. Increasing the taper of the storage material improves both efficiency and power output. {copyright} {ital 1996 American Institute of Physics.}
1996-02-01
Radius of thawing around an injection well and time of complete freezeback
An approximate method of calculating the radius of thawing around an injection well is presented. The method is based on the assumption that for a cylindrical system the position of the phase interface in the Stefan problem can be approximated through two functions: one function determines the position of the melting-temperature isotherm in the problem without phase transitions and the second function does not depend on time. The adjusted heating time concept was used to describe the first function. The second function is a known analytical relationship and is expressed in terms of ice content, thermal properties of thawed/frozen formations, formation temperature and the temperature of the injected fluid. Simple approximate formulae are suggested to estimate the duration of the freezeback period. To verify the proposed formulae, the results of numerical solutions were used. An example which shows that the duration of the 'safety period' (free ...
2006-06-01
Proteomic analysis of apoptosis induction in human lung cancer cells by recombinant MVL
British Library Electronic Table of Contents (United Kingdom)
Lung cancer is still difficult to treat by current chemotherapeutic procedures. We recently found that MVL, an anti-HIV lectin from blue-green algae Microcystis viridis, also has antitumor activity. The objective of this study was to investigate apoptosis-inducing activity of recombinant MVL (R-MVL) and proteomic changes in A549 cells, and to identify the molecular pathways responsible for the anti-cancer action of R-MVL. We found that R-MVL induces A549 cells apoptosis in a dose-dependent manner by using MTT assay, fluorescent microscope (FM) and flow cytometry (FCM), and the IC50 was calculated to be 24.12??g/ml. Subsequently, 7 altered proteins in R-MVL-treated A549 cells were identified, including upregulated aldehyde dehydrogenase 1 and ?-actin, and five downregulated proteins: heat s...
2011-01-01
Optimization of decontamination strategy for CANDU-PHW reactors
International Nuclear Information System (INIS)
Theoretical models of the decontamination process are developed and combined with an existing model of "6"0Co production in CANDU PHW reactors to predict the effects of decontamination on long term "6"0Co build-up in reactor primary heat transport systems. The effects of decontamination interval, decontamination factor, and post-decontamination corrosion release are calculated. An optimum decontamination strategy for a Pickering G.S. type reactor is developed on the basis of a cost-benefit analysis. This study indicates that the optimum decontamination interval is approximately six years. This optimum interval is relatively insensitive to variations in the costs of personnel exposure, the cost of a decontamination, the decontamination factor, and the post-decontamination corrosion model used. (author).
Natural convection cooling of the IFMIF target and test cell
International Nuclear Information System (INIS)
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
The liquid/vapor coexistence density, the partial vapor pressure, and the heat of vaporization were calculated using Gibbs ensemble Monte Carlo simulation techniques. Long-range interactions such as charge-charge, charge-dipole, and dipole-dipole were evaluated using Ewald summation techniques. A polarizable potential model was used to describe the water-water interactions (Dang and Chang, J. Chem. Phys. 106, 8149, 1997). The model yields good agreement with the corresponding experimental data in the lower temperature region and moderate agreement in the higher temperature region. The critical temperature and density were estimated to be 565 K and 0.28 g/cm3.
2001-12-01
FIRESET is a PC-based computer code which calculates current as a function of time for an RLC circuit containing up to fifteen series conductors which undergo rapid heating and subsequent explosion as a consequence of an electric current which passes through them. In its original form, the code was developed to model electrical waveforms measured when a large, typically 25.4 x 25.4 x 0.051-mm, aluminum foil was exploded using a capacitor bank with tens of kilojoules of stored energy. The code proved to be useful for this purpose, and it was recognized that it could also be used for modeling the electrical response of detonator bridgewires. In view of the increasing use of slapper detonators for DOD applications, we wish to make the latest version of the code, available to DOD laboratories and contractors for use in designing firing systems which employ slapper or exploding bridgewire detonators. This document provides instructions for the code.
1988-02-19
FFTF reactor characterization program
International Nuclear Information System (INIS)
Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.
Exergy analysis of the solar multi-effect humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heat exchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...
2007-01-01
Electrostatic discharge effects on EBW detonators
With appropriate circuit resistance and inductance and sufficient stored energy, discharging a charged human body or component through an exploding bridgewire (EBW) detonator may cause the detonator to function or may damage the detonator. We have studied the effects of electrostatic discharge (ESD) on a number of exploding bridgewire detonators which were subjected to discharges which passed directly through the bridgewires (pin-to-pin), as well as discharges which passed from the bridge to the metal case of the detonator (pin-to-case). We have performed calculations to determine the values of inductance and resistance for which burst and melt may occur for given ESD sources, using a phenomenological model of bridgewire burst in a computer code called FIRESET. Bridge melt was computed using the same computer code, but using experimental values of bridge resistivity and specific heat up to melt. 13 refs., 5 figs.
1991-04-01
International Nuclear Information System (INIS)
Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.
1999-03-29
Current drive and heating systems based on high-energy (1- to 3-MeV) negative ion beams
Energy Technology Data Exchange (ETDEWEB)
This paper describes a concept for a current drive system based on negative ions with beam energy > 1 MeV. Preliminary physics calculations show that the core current necessary for stability enhancement can best be achieved by beams with energy ranging from 1 to 4 MeV. Further study and experiments will better define the optimum energy. Work under way at Oak Ridge National Laboratory (ORNL) and at collaborating institutes in Canada and the Federal Republic of Germany is defining a system, its elements, a configuration and operational scenarios deemed appropriate for such devices as ITER and other future steady-state tokamaks, and the requisite research and development to provide such a system. 7 refs., 2 figs.
1988-01-01
CFD analysis and overheating control of a turbine
Energy Technology Data Exchange (ETDEWEB)
The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the installation of external ...
2004-11-01
Australia's Latrobe Valley brown coal fields
Energy Technology Data Exchange (ETDEWEB)
Brown coal resources of the Latrobe Valley in Australia total 140 billion tons to a depth of 975 feet, while economically recoverable reserves have been calculated to total 57 billion tons. Although the coal provides only a very low heating value, about 3300 Btu/lb with 60% moisture content, the enormous seam thicknesses with little overburden allow large scale, open cut mining operations. The low cost and high reactivity of the coal is attracting extensive coal liquefaction research. Research into dewatering processes for the high moisture content brown coal is being conducted. The dried brown coal could be used both domestically and internationally for electricity generation and as an industrial fuel.
1984-02-01
Energy Technology Data Exchange (ETDEWEB)
An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance data.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Examination is made of the main features of the physical and chemical preignition processes within homogeneous mixtures of air and gaseous fuels, such as propane, methane and hydrogen in a motored engine, while employing detailed chemical kinetics in a one zone analytical model. The changes in the compression temperature and pressure due to the admission of gaseous fuels, energy release during the preingition reactions and the contributions of heat transfer and residual gases to the preignition reaction activity were followed over a number of consecutive cycles until the occurrence of autoignition. Some of the observed differences in engine behaviour when operating on methane, propane and hydrogen were discussed with particular reference to the observed trends in dual fuel engine operation. Calculated results showed good agreement with some corresponding experimental trends. 14 refs., 9 figs.
1994-10-01
A cone concentrator for high-temperature solar cavity-receivers
Energy Technology Data Exchange (ETDEWEB)
A cone concentrator combined with a solar cavity receiver is presented and its performance compared to a single cavity receiver. For both cases the available heat sink within the receiver is calculated. The cone concentrator suffers from a high amount of rejected rays if the exit aperture is made too small. A larger exit aperture on the other hand increases the thermal losses of the cavity. The optimum cone geometry therefore has to be found taking also into account a model of the cavity. Different operating temperatures and different values of absorption coefficients of the cavity walls are considered. A cone concentrator was built and tested at the solar furnace in Cologne. It transmits 97 percent of the rays entering the entrance aperture, which is in exact agreement with the theoretical predictions. (author)
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The following subjects were discussed at the conference: Stability of welded joints, creep stress in CrMo steels, life prediction, developments in modern power plant steels, testing, calculation of deformation, crack propagation and crack analysis under complex loads. [German] Die Autoren der Tagung referieren ueber folgende Themen: Stabilitaet von Schweissverbindungen, Kriechbeanspruchung von Chrom-Molybdaen Staehlen, Lebensdauervorhersage, Entwicklungen fuer die Anwendung in modernen Kraftwerken, Prueftechnik, Berechnung von Verformung, Rissentwicklung und -bewertung bei komplexer Beanspruchung. (uke)
2002-07-01
Process model for carbothermic production of silicon metal
Energy Technology Data Exchange (ETDEWEB)
This thesis discusses an advanced dynamical two-dimensional cylinder symmetric model for the high temperature part of the carbothermic silicon metal process, and its computer encoding. The situation close to that which is believed to exist around one of three electrodes in full-scale industrial furnaces is modelled. This area comprises a gas filled cavity surrounding the lower tip of the electrode, the metal pool underneath and the lower parts of the materials above. The most important phenomena included are: Heterogeneous chemical reactions taking place in the high-temperature zone (above 1860 {sup o}C), Evaporation and condensation of silicon, Transport of materials by dripping, Turbulent or laminar fluid flow, DC electric arcs, Heat transport by convection, conduction and radiation. The results from the calculations, such as production rates, gas- and temperature distributions, furnace- and particle geometries, fluid flow fields etc, are ...
1995-09-12
Optimization of district heating power stations; Optimierung von Blockheizkraftwerken
Energy Technology Data Exchange (ETDEWEB)
A computer program for optimization of modular cogeneration plants is introduced. Computer calculation fundamentals are discussed referring to examples which elucidate the verification of the calculated data by measured data or empirical values. The results obtained as one optimizes plants by varying their size or by splitting them into modules are introduced referring to examples. Sensitivity analyses are made to investigate the influence of parameters such as fuel prices, electricity tariffs and interest rates. (orig.) [Deutsch] Im vorliegenden Beitrag wird ein Computerprogramm zur Optimierung von BHKW-Anlagen vorgestellt. Zunaechst werden in einem ersten Schritt die Berechnungsgrundlagen an einem Beispiel in Hinblick auf ihre Ueberpruefung durch Messdaten oder durch Erfahrungswerte diskutiert. Dann werden in einem zweiten Schritt exemplarisch die Ergebnisse einer Optimierung durch Variation der Gesamtanlagengroesse auf Aufsplittung der ...
1994-10-01
On the off-design of a natural gas-fired combined cycle with CO{sub 2} capture
Energy Technology Data Exchange (ETDEWEB)
During the last 15 years cycles with CO{sub 2} capture have been in focus, due to the growing concern over our climate. Often, a natural gas fired combined cycle with a chemical absorption plant for CO{sub 2} capture from the flue gases have been used as a reference in comparisons between cycles. Neither the integration of the steam production for regeneration of amines in the combined cycle nor the off-design behaviour of such a plant has been extensively studied before. In this paper, the integration of steam production for regeneration of the amines is modelled at design load and studied in off-design conditions for a combined cycle. Different ambient conditions and part-load strategies and their influence on the cycle performance are also examined. Of particular interest is a novel strategy with the possibility of longer life of gas turbine blading, with marginal loss in efficiency. The off-design performance of the combined cycle is modelled in a rigorous way using a gas turbine ...
2007-04-15
Energy Technology Data Exchange (ETDEWEB)
A central issue to be addressed within the Nevada Nuclear Waste Storage Investigations (NNWSI) is the role which fractures will play as the variably saturated, fractured rock mass surrounding the waste package responds to heating, cooling, and episodic infiltration events. Understanding the role of fractures during such events will, in part, depend on our ability to make geophysical measurements of perturbations in the moisture distribution in the vicinity of fractures. In this study we first examine the details of the perturbation in the moisture distribution in and around a fracture subjected to an episodic infiltration event, and then integrate that behavior over the scale at which moisture measurements are likely to be made during the Engineered Barrier Design Test of the NNWSI project. To model this system we use the TOUGH hydrothermal code and fracture and matrix properties considered relevant to the welded ash flow tuff found in the Topopah Spring member at ...
1988-05-31
Energy Technology Data Exchange (ETDEWEB)
A one-way coupling system between the plant simulator TRAC/BF1-ENTREE and the subchannel code with the improved cross flow model, NASCA, has been developed. Based on a scenario of turbine trip tests in the Peach Bottom Unit 2, the wide and rapid reactivity insertion transient induced by the system pressure rise was calculated. The pin power distribution in hot bundles was re-constructed considering heterogeneity of the fuel bundle. When the neighboring control blade is withdrawn, NASCA predicted that the steady-state bundle exit void distribution was nearly flat with regardless of the pin power distribution. However, void distributions in the middle and lower bundle regions became complicated depending on the pin power and the two-phase flow regime in each subchannel. The pin power distribution rapidly changed according to traveling of control blades. However, influence in the void distribution was delayed and damped due to the fuel heat ...
2002-11-01
Analytical model for the dynamic resistivity of electrically-exploded conductors
A detailed model for the dynamic resistivity of an exploding conductor presents many difficulties. An electrically-exploded conductor undergoes significant hydrodynamic expansion as it is heated. Resistivity is a function of both the temperature and density of a conductor and realistic models for resistivity over the range of parameter space experienced by an exploding conductor are quite complex. See for example, the model of Lee and More (1984). Calculation of the hydrodynamic expansion of the conductor during and subsequent to the explosion is likewise dependent on detailed knowledge of the equation of state for the conductor in a range where few experimental data exist. A further complication is the strong magnetic field which couples the hydrodynamic expansion to the currents flowing in the expanding material. In spite of the difficulties, progress is being made on detailed modeling of fuses and exploding conductors (Lidemuth and ...
1986-10-10
Analysis of natural convection in narrow annular gaps of LMFBR
International Nuclear Information System (INIS)
The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiant heat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code coincided with that obtained ...
Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator
Energy Technology Data Exchange (ETDEWEB)
Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity ...
2001-10-01
Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator
International Nuclear Information System (INIS)
Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity into the ...
2001-10-01
A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator
International Nuclear Information System (INIS)
A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the steam component in the ...
1994-01-01
Heat transfer problems in high temperature heat exchangers
International Nuclear Information System (INIS)
This paper deals with construction types of high temperature heat exchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiant heat transfer interaction in high temperature heat exchangers. The ways of heat transfer augmentation and efficient heat exchanger construction are discussed.
1986-01-01
Development of wood fuel delivery logistics; Puupolttoaineiden hankintalogistiikan kehittaeminen
Energy Technology Data Exchange (ETDEWEB)
The main aim of the project is to model the energy wood business and total logistics in a certain large region. First, wood utilisation locations inside this area are examined; the most important ones are the wood processing factories, and the heating- and power plants. After that, wood potentials in the forests of the area are evaluated in sub-areas suitable in size and sufficiently detailed for further evaluations. For that purpose, the most valuable source data are forest management plans, up to ten years forward, on which basis the wood fuel potentials can be evaluated following sustainable development. In Finland there are extensive and detailed data bases storing forest information and it is possible to collect necessary data for a data base applicable to our calculations. In logistical sense it is important to know, by which delivery chains the economically best and desired results are achieved. The software prototype based on data base ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.
1989-01-01
The effect of family processes on school achievement as moderated by socioeconomic context
British Library Electronic Table of Contents (United Kingdom)
This longitudinal study examined a model of early school achievement in reading and math, as it varies by socioeconomic context, using data from the NICHD Study of Early Child Care and Youth Development. A conceptual model was tested that included features of family stress, early parenting, and school readiness, through both a single-group analysis and also a multiple-group analysis. Latent profile analysis was used to identify subgroups of more advantaged and less advantaged families. Family stress and parenting were shown to operate differently depending on the socioeconomic context, whereas child-based school readiness characteristics were shown to operate similarly across socieodemographic contexts. Implications for intervention are discussed.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The thermal spike model has been successfully applied to track formation by swift heavy ions in insulators. Arguments are given supporting the assumption that the thermal spike mechanism is also valid for the anisotropic growth. The glass transition temperature is used as the main thermal parameter of the amorphous solids. Experimental results on the track formation in {alpha}-quartz and in crystalline Ni{sub 3}B and also on the anisotropic growth in Pyrex and Synsil glasses, in amorphous Pd{sub 80}Si{sub 20}, Ni{sub 3}B and Fe{sub 85}B{sub 15} are discussed. Good agreement is found with the predictions of the thermal spike model. (orig.).
1996-02-01
TNF-alpha antagonist therapy modify the tuberculin skin test response
British Library Electronic Table of Contents (United Kingdom)
Tumour necrosis factor-alpha (TNF-?) antagonist drugs have been associated with increased risk of tuberculosis (TB). Tuberculin skin test (TST) is the most frequently used tool for identification of latent TB infection. We herein aimed to analyse the effect of TNF-? antagonists on the TST responses in a prospective study. The study group consisted of 182 patients (99 female, 83 male) who received TNF-? antagonists for various rheumatic disorders. All patients were evaluated with TST along with other parameters on the day of referral and on the 12th month visit. For those patients with a response of <5?mm induration at the initial evaluation, the TST was repeated to observe the booster effect. Out of 182 patients, 87 patients (48%) had a negative (0?4?mm) and 95 (52%) had a positive (?5?mm)...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Background Previous reports in adults have suggested that the effects experienced after cannabis use can be described in terms of positive and negative subtypes that are heritable and are associated with abuse and dependence. This study extends existing research by inclusion of adolescents and young adults in an offspring of twins design which makes it possible to take into account genetic and environmental risks for substance use disorder. Methods Data were collected from 725 twin members of the Vietnam Era Twin Registry, 839 of their 12-32 year old biological offspring and 427 mothers. Offspring who had ever used cannabis (n=464) were asked the degree to which they typically experienced 13 subjective effects shortly after using cannabis. Latent class analysis (LCA) was used to derive sub...
2009-01-01
Environmental Research Database
ObjectivesTo determine the reaction rate of slag during curing and factors affecting reactivity.~%~~%~To measure the rates of chloride ingress into concrete and the extent of chloride binding.~%~~%~To determine conditions for pitting corrosion and the nature of corrosion products.~%~~%~To characterise the reactions in slag-calcium alumina cement hydration and the nature of the products.~%~DescriptionBlast-furnace slag has latent hydraulic properties, giving considerable potential for commercial use in addition to its widespread use as a partial replacement for Portland cement, notably in alkali-activated slag (AAS) and slag-calcium alumina cement (CAC) concretes. Use of AAS concretes is already well-established in China and the former USSR, but their further application is hindered by lack of research into setting, hydration and durability, Slag/CAC blends are new materials whose chemistr [continued...
1999-01-09
British Library Electronic Table of Contents (United Kingdom)
The primary objective of batch data as trajectory alignment (or synchronization) is to standardize the data sampling per batch according to the evolution of the process, and secondarily to homogenize the samples per run. The use of an indicator variable performs both objectives well. Two examples from the pharmaceutical sector are discussed to illustrate the different ways to deal with uneven samples across batches and across variables in the same batch. Since trajectory alignment requires large time investment, a simple triage approach is proposed to assess the need to analyze the dynamics of a given process and hence perform alignment. The presented examples are representative of a broad variety of batch processes that are operated by recipe in the pharmaceutical sector. In our experienc...
2011-01-01
Empirically defined subtypes of alcohol dependence in an Irish family sample
British Library Electronic Table of Contents (United Kingdom)
Alcohol dependence (AD) is clinically and etiologically heterogeneous. The goal of this study was to explore AD subtypes among a sample of 1221 participants in the Irish Affected Sib Pair Study of Alcohol Dependence, all of whom met DSM-IV criteria for AD. Variables used to identify the subtypes included major depressive disorder, antisocial personality disorder, illicit drug dependence (cannabis, sedatives, stimulants, cocaine, opioids, and hallucinogens), nicotine dependence, the personality traits of neuroticism and novelty seeking, and early alcohol use. Using latent class analysis, a 3-class solution was identified as the most parsimonious description of the data. Individuals in a Mild class were least likely to have comorbid psychopathology, whereas a severe class had highest probabi...
2010-01-01
International Nuclear Information System (INIS)
Endophytes are microorganisms that live within healthy plant tissues, and include fungi and bacteria. They can be mutualists, comensals or even latent pathogens. Presence of these endosymbionts may affect host physiology, for example by consuming products of photosynthesis (endophytes are heterotrophs) or producing toxic metabolites. In this work two fungicides were used to eliminate fungal endophytes from seedlings of guarea guidonia. light saturated photosynthesis (Amax) was measured in endophytefree plants and compared with control plants. Each fungicide killed different fungal endosymbionts. phomopsis was more susceptible to benomyl while colletotrichum was more susceptible to propiconazole. Although suggestive, values of Amax were not significantly different for each treatment compared with control plants. No prediction can be made at this point about the final outcome of a given plantendophytic fungi interaction
2005-12-01
Does superior firm performance lead to higher quality outside directorships?
British Library Electronic Table of Contents (United Kingdom)
Purpose - Holding the number of outside directorships constant, this paper aims to test whether executive directors from superior performing firms are subsequently rewarded with better quality outside directorships. Design/methodology/approach - The quality of new outside directorship appointments is modelled using a two-step Heckman selection procedure to control for the probability of acquiring a new outside board seat. Outside directorship quality is estimated using an index formed from series of observable firm-specific characteristics proxying for the following three latent aspects of quality: prestige, reputational risk and monetary rewards. The index aggregates across these three dimensions to produce an overall quality score, with higher scores signifying higher quality directorshi...
2008-01-01
Association study of SNAP25 and schizophrenia in Irish family and case-control samples
British Library Electronic Table of Contents (United Kingdom)
SNAP25 occurs on chromosome 20p12.2, which has been linked to schizophrenia in some samples, and recently linked to latent classes of psychotic illness in our sample. SNAP25 is crucial to synaptic functioning, may be involved in axonal growth and dendritic sprouting, and its expression may be decreased in schizophrenia. We genotyped 18 haplotype-tagging SNPs in SNAP25 in a sample of 270 Irish high-density families. Single marker and haplotype analyses were performed in FBAT and PDT. We adjusted for multiple testing by computing q values. Association was followed up in an independent sample of 657 cases and 411 controls. We tested for allelic effects on the clinical phenotype by using the method of sequential addition and 5 factor-derived scores of the OPCRIT. Nine of 18 SNPs had P values <...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
IntroductionFocusing on people and organizations, this paper aims to contribute to offshore safety assessment by proposing a methodology to model causal relationships.MethodThe methodology is proposed in a general sense that it will be capable of accommodating modeling of multiple risk factors considered in offshore operations and will have the ability to deal with different types of data that may come from different resources. Reason's ?Swiss cheese?? model is used to form a generic offshore safety assessment framework, and Bayesian Network (BN) is tailored to fit into the framework to construct a causal relationship model. The proposed framework uses a five-level-structure model to address latent failures within the causal sequence of events. The five levels include Root causes level, Tr...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Low-temperature specific-heat measurements have been carried out between 0.5 and 30--50 K on the high-T/sub c/ copper oxide superconductors La/sub 1.8/Sr/sub 0.2/CuO/sub 4-//sub delta/ and RBa/sub 2/Cu/sub 3/O/sub 7-//sub delta/ (R = Y, Eu, Ho, Tm, and Yb). The specific heat of the La/sub 1.8/Sr/sub 0.2/CuO/sub 4-//sub delta/ and YBa/sub 2/Cu/sub 3/O/sub 7-//sub delta/ compounds below T/sub c/ can be resolved into a contribution of the form C/sub e/(T) = ..gamma..'T with a finite ..gamma..' and a lattice contribution that consists of Debye and Einstein terms. Specific-heat data for the RBa/sub 3/Cu/sub 3/O/sub 7-//sub delta/ compounds with R = Ho, Tm, and Yb exhibit no features due to magnetic order above 0.5 K, but reveal electronic Schottky anomalies associated with crystalline electric field (CEF) splitting of the Hund's-rules ground-state multiplet of the R/sup 3+/ ions. The Schottky anomalies ...
1988-02-01
International Nuclear Information System (INIS)
Wolsong 2,3 and 4 fuel channel analysis during a large break loss of coolant accident with loss of ECCS injection (LOCA/LOECC) is performed to obtain the heat load to moderator. Because the single channel analysis requires the establishment of the safety codes and their input decks, the present study follows the same safety analysis methodology found in FSAR of Wolsong 2,3 and 4. From this work we obtain the safety tools such as CATHENA MOD3.5b/Rev.1 and CHAN-II/A MOD2 codes, and their code modeling in a form of code input deck. The analysis consists of two parts: front-end (blowdown period) and back-end. For the front-end analysis the fuel and pressure tube (PT) temperatures, and PT circumferential strains at the end of front-end as well as fuel channel depressurization are calculated using CATHENA code and used as initial and boundary conditions for back-end analysis. The back-end period under the conditions of prolonged low steam flow is ...
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives values of Rainier Mesa 0.15 +- .01, Paintbrush 0.18 +- .03, Tunnel Beds 0.20 +- .04, and ...
1981-05-01
Study of the thermal plasma etching at atmospheric pressure on silica rods
International Nuclear Information System (INIS)
Etching of SiO_2 rods has been obtained with a dc torch with argon as the process gas in an air environment at atmospheric pressure; the high temperature of the plasma jet causes vaporization of the exposed area. The apparatus and torch operative parameters have been set up to obtain a depth etch rate of up to 0.6 mm min"-"1 corresponding to 0.826 g min"-"1. An enthalpy probe has been employed to monitor the plasma conditions before the thermal plasma etching process and from the experimental etch rate a surface rod temperature of T_s_u_r = 2057 K has been derived. Etching has been obtained with uniformity over the entire exposed area with peak to peak differences below 1%. The plasma to rod heat transfer has been simulated using a commercial CFD code Fluent (copyright). The model consists of a non-steady two-dimensional simulation for a compressible turbulent fluid, with an adapted grid calculation. Boundary conditions have been set out using ...
2004-04-21
Energy Technology Data Exchange (ETDEWEB)
The presented paper describes the formulation of the fractional mass balances which are used to calculate the concentration and size distribution of char in the balance cells of a circulating fluidized bed boiler. In case of using the shrinking core model additionally the distribution of conversion of the char particles is calculated. Basically two reaction models (a shrinking particle and a shrinking core model) are available to describe the combustion process. The model considers all essential physico/chemical phenomena (primary fragmentation, attrition, mass transfer to gas phase) which have to be taken into account for the description of the combustion process. The model is part of an overall simulation program for circulating fluidized bed boilers. This engineering simulator has been developed to return the main performance parameters of such systems like temperature along the furnace height, size distribution of balanced solid components, ...
1998-12-31
Development and use of localized arc filament plasma actuators for high-speed flow control
International Nuclear Information System (INIS)
The paper discusses recent results on the development of localized arc filament plasma actuators and their use in controlling high-speed and high Reynolds number jet flows. Multiple plasma actuators (up to 8) are controlled using a custom-built 8-channel high-voltage pulsed plasma generator. The plasma generator independently controls pulse repetition rate (0-200 kHz), duty cycle and phase for each individual actuator. Current and voltage measurements demonstrated the power consumption of each actuator to be quite low (20 W at 20% duty cycle). Emission spectroscopy temperature measurements in the pulsed arc filament showed rapid temperature increase over the first 10-20 ?s of arc operation, from below 1000 deg. C to up to about 2000 deg. C. At longer discharge pulse durations, 20-100 ?s, the plasma temperature levels off at approximately 2000 deg. C. Modelling calculations using an unsteady, quasi-one-dimensional arc filament model showed that rapid localized ...
2007-02-07
Computational fluid dynamic analysis of core bypass flow phenomena in a prismatic VHTR
International Nuclear Information System (INIS)
The core bypass flow in a prismatic very high temperature reactor (VHTR) is an important design consideration and can have considerable impact on the condition of reactor core internals including fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) are affected by bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to better understand bypass flow phenomena and establish an evaluation method for the reactor core using the commercial CFD code FLUENT. Parametric calculations ...
2010-09-01
Computational Fluid Dynamic Analysis of Core Bypass Flow Phenomena in a Prismatic VHTR
Energy Technology Data Exchange (ETDEWEB)
The core bypass flow in a prismatic very high temperature gas-cooled reactor (VHTR) is one of the important design considerations which impacts considerably on the integrity of reactor core internals including operating fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) will be affected by the bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to understand better the bypass flow phenomenon and establish the evaluation method in the reactor core using commercial CFD code FLUENT. Parametric ...
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
Polychlorinated dibenzo-p-dioxins and dibenzo-furans form a family of more than 200 compounds which are relatively stable in the biosphere and tend to accumulate in the human body. The tetra- to hexa-chlorinated dioxins and furans are considered highly toxic. To facilitate the assessment of the total toxicity of dioxin and furan mixtures, the estimated toxic effects of the individual compounds relative to the 2,3,7,8-tetrachloro-dibenzo-p-dioxin (TCDD) were introduced as Toxic Equivalent Factors which yield, when multiplied with the respective concentrations, the Toxic Equivalent (TE) of the mixture. Toxic dioxins and furans are unintentionally formed in a number of industrial combustion processes such as waste incineration and iron ore sintering, in the chemical industry and in household heating. To keep the emissions as low as possible, off-gas clearing systems for the collection of dioxins and furans are increasingly prescribed by the authorities. In addition, ...
1997-12-31
Cylindrical heat receiver for thermal solar-energy converters
Energy Technology Data Exchange (ETDEWEB)
Theoretical and experimental results of investigating a cylindrical heat receiver with secondary reflectors are presented. One important element of solar thermal power plants (STPP) is the heat receiver. Several forms of heat receiver exist; the main form is the heat receiver of cavity form (including cylindrical, rectangular, and cubic heat receivers with a noncircular aperture). The linear dimension of such heat receivers is equal to, or larger than, the theoretical diameter of the concentrator focal spot.
1984-01-01
Advances in enhanced heat transfer: 1987
Energy Technology Data Exchange (ETDEWEB)
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
1987-01-01
Advances in enhanced heat transfer: 1987
International Nuclear Information System (INIS)
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
1987-08-09
Energy Technology Data Exchange (ETDEWEB)
Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1998-02-01
International Nuclear Information System (INIS)
Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1999-11-03
International Nuclear Information System (INIS)
Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1998-03-16
Cask consolidated spent fuel thermal analyses using the COBRA-SFS code
Energy Technology Data Exchange (ETDEWEB)
The COBRA-SFS computer code was used to perform thermal-hydraulic analyses of consolidated spent fuel stored in casks. The ability of the COBRA-SFS code to model consolidated fuel was evaluated by comparing predictions with experimental data obtained from electrically heated rod bundles by Ridihalgh, Eggers, and Associates and Eggers Ridihalgh Partners, Inc. under sponsorship of the Electric Power Research Institute. The calculations agreed with the measured temperatures well within the bounds of experimental error. Based on the evaluation results, best-estimate temperature predictions were performed for consolidated fuel in several cask designs. Results are presented for the REA 2023 BWR cask, the CASTOR-1C BWR cask, and the Concrete Sealed Storage Cask designed for Monitored Retrievable Storage (MRS). The cask simulation results indicate that consolidation of spent fuel results in a reduction of convection and radiation ...
1986-04-01
Emergency core cooling device for a reactor
International Nuclear Information System (INIS)
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
1982-01-24
Optimal thermodynamic heat transfer
Energy Technology Data Exchange (ETDEWEB)
This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.
1989-06-01
Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger
International Nuclear Information System (INIS)
In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. ...
2003-05-28
Conjugate Heat Transfer Predictions of a Combustor ...
... To maximise heat transfer rates, many heatshield designs make use of heat transfer augmentation devices such as large numbers of pin-fin ...
2003-03-01
Augmentation of heat and mass transfer
Energy Technology Data Exchange (ETDEWEB)
This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.
1986-01-01
Introduction. This study used Item-Response Theory (IRT) to model the psychometric properties of a false belief picture sequencing task. Consistent with the mental time travel hypothesis of paranoia, we anticipated that performance on this deductive theory of mind (ToM) task would not be associated with the presence of persecutory delusions but would be related to other clinical, cognitive, and demographic factors. Method. A large (N=237) and diverse clinical and nonclinical sample differing in levels of depression and paranoid ideation performed 2 ToM tasks: the false belief sequencing task and a ToM stories task that was used to assess the validity of the false belief sequencing task as a measure of ToM. Results. A unidimensional IRT model was found to fit the data well. Latent ToM ability as measured by the false belief sequencing task was negatively related with age and positively with IQ. In contrast to the ToM stories measure, there was no association between ...
2011-08-15
Simulation of natural convection cooling phenomena for research reactors using the code PARET
International Nuclear Information System (INIS)
This study deals with testing the capability of the code PARET to simulate natural convection cooling phenomena under different boundary conditions. In addition to applying and testing some new options related to simulation of the control rod movement and studying the reactivity effect of thermal expansion fuel elements. The experiments of the simple thermal hydraulic loop of Missouri university about natural cooling phenomena in two narrow paralled channels were used to validate the code. The study indicate good results regarding the distribution of coolant flux velocity and clad temperature. In particular the heat transfer coefficient of natural convection has been calculated in good agreement with the experiment. On the other hand, the core of MNSR reactor has been modelled to simulate the reactor dynamic behaviour under natural convection cooling conditions for different initial power level. The observed oscillation during the initial phase ...
International Nuclear Information System (INIS)
The isostructural #gamma#-#alpha# phase transition of Ce which occurs at 8 kbar has been studied by means of fully self-consistent (non-muffin-tin potential) linearized-augmented-plane-wave energy band calculations carried out for five different values of the lattice constant. In contradiction to the 4f electron promotional model of the transition, the results yield essentially one 4f electron to be occupied in each phase but with the 4f wave function somewhat less localized, and therefore more bandlike, in the ''collapsed'' #alpha# phase. A singly occupied 4f state is shown to be consistent with the available experimental data. These results strongly support the picture of a 4f localized bold-arrow-left-right itinerant transition at the #gamma#-#alpha# transition and conflict with the promotional model in which some fraction of 4f electrons are transferred to the sd conduction bands. The weaker bonding of the 4f electrons, compared to that of the 6s-5d valence ...
HEXTRAN-SMABRE calculation of the 6th AER Benchmark, main steam line break in a WWER-440 NPP
International Nuclear Information System (INIS)
The sixth AER benchmark is the second AER benchmark for couplings of the thermal hydraulic codes and three dimensional neutron kinetic core models. It concerns a double end break of one main steam line in a WWER-440 plant. The core is at the end of its first cycle in full power conditions. In VTT HEXTRAN2.9 is used for the core kinetics and dynamics and SMABRE4.8 as a thermal hydraulic model for the primary and secondary loop. The plant model for SMABRE consists mainly of two input models, Loviisa model and a standard WWER-440/213 plant model. The primary loop includes six separate loops, the pressure vessel is divided into six parallel channels in SMABRE and the whole core calculation is performed in the core with HEXTRAN. The horizontal steam generators are modelled with heat transfer tubes in five levels and vertically with two parts, riser and downcomer. With this kind of detailed modelling of steam generators there occurs strong flashing ...
2003-11-01
Energy Technology Data Exchange (ETDEWEB)
The fixed bed pilot plant, the catalyst testing procedure, and the calculations for conversion and selectivities were previously described in the technical progress report covering the period of 3/16/88 to 6/16/88 for Contract DE-AC22-87PC79812. Conversions and hydrocarbon selectivities were calculated using data from an on-line gas chromatography (GC) analyzer. Alcohol selectivities were calculated using data from an on-line boiling point GC analyzer which analyzed the liquid product. The catalysts were prepared via the steps of impregnation, calcination, and reduction on a special Y-zeolite-derived support. The impregnation step consisted of evaporation of metal salts on to the support from an aqueous solution. For one catalyst (No. 6531-188) the metal salts were evaporated on to the support from a reverse micelle solution containing the metal salts. All the catalysts were calcined for four hours at 450{degree}C. The ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
This study follows previous experimental work showing that the shrinking-core model applies to the pyrolysis (i.e., heating in the absence of oxygen) of particles (diam.{approx}14 mm) of a bituminous coal or a lignite in a fluidized bed at 700-950 {sup o}C. These experimental facts are in accord with the production of volatile matter being endothermic and not thermoneutral, as often assumed. Also, the rate at which volatile matter is produced in the presence of oxygen (i.e., devolatilization) or in its absence (pyrolysis) is demonstrated here to be controlled not at all by mass transfer, but by heat conduction to a moving reaction front inside a coal particle, provided its diameter exceeds {approx}3 mm. The resulting steady-state model of devolatilization indicates that six dimensionless groups are required to describe the rate of(I)coal->char+volatile matter for a nonfragmenting and nonswelling coal. This reaction occurs for a total ...
2006-08-15
Municipal Heat Wave Response Plans
UK PubMed Central (United Kingdom)
Approximately 400 people die from extreme heat each year in the United States, and the risk of heat waves may increase as a result of global climate change. Despite the risk of heat-related morbidity...Full Text Available
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
Several heat transfer augmentation mechanisms contribute to the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. Among those contributions, that of heat exchange was numerically analyzed and characteristically elucidated by the unsteady direct contact heat conduction at the time of impingement between the laden particles and heat transfer surface. In other words, if the contact time is short between the particles and heat transfer surface, the former is heated by heat stored in the latter as a heat capacity. In such a region, the heat quantity to be transferred to the particles changes by not only the thermal property value (heat capacity multiplied by heat conduction coefficient) of ...
1991-05-25
Heat transfer. Fundamentals. 5. rev. ed.
International Nuclear Information System (INIS)
This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heat exchangers. It includes the physical foundations for all these aspects and many examples. (orig.)
ASME proceedings of the 31. national heat transfer conference: Volume 2. HTD-Volume 324
Energy Technology Data Exchange (ETDEWEB)
This volume is divided into the following sections: (1) fundamentals of convection heat transfer; (2) fundamentals of heat transfer with impinging jets; and (3) fundamentals of heat transfer augmentation. Separate abstracts were prepared for most papers in this volume.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
1994-07-01
The Effect of the Temperature to Which the Material is Heated ...
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
1980-09-01
SPECIAL EDDY CURRENT PROBES FOR HEAT ...
... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...
1986-11-01
Development of a geothermal heat pump. Final report
Energy Technology Data Exchange (ETDEWEB)
In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.
1981-11-02
Heat transfer augmentation in rod bundles near grid spacers
International Nuclear Information System (INIS)
Heat transfer augmentation by straight grid spacers in rod bundles is studied for single phase flow and for post critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single phase flow is also examined. Governing heat transfer mechanisms are analyzed, and predictive formulations are established. For single phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. 18 refs.
1980-01-01
Geothermal heat-pump systems of heat supply
International Nuclear Information System (INIS)
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
2004-06-01
Air-side flow and heat transfer in compact heat exchangers: A discussion of enhancement mechanisms
Energy Technology Data Exchange (ETDEWEB)
The behavior of air flows in complex heat exchanger passages is reviewed with a focus on the heat transfer effects of boundary-layer development, turbulence, spanwise and streamwise vortices, and wake management. Each of these flow features is discussed for the plain, wavy, and interrupted passages found in contemporary compact heat exchanger designs. Results from the literature are used to help explain the role of these mechanisms in heat transfer enhancement strategies.
1998-10-01
Binary heat pump system. Binary heat pump system
Energy Technology Data Exchange (ETDEWEB)
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This ...
1993-11-30
Al2O3-based ceramic is one of the most widely used materials for tools employed in hardened steel turning applications due to its high hardness, wear resistance, heat resistance and chemical stability. The objective of this work is to predict the lives of Al2O3-(W, Ti)C ceramic tools in intermittent turning of hardened AISI 1045 steel by means of damage evolution model taking into account the mechanical loading and thermal effect in the cutting process. A damage evolution model analyzing the RVE with uniformly distributed interacting cracks is constructed based on micromechanics. The calculated results of the proposed damage evolution model are compared with the lives of two kinds of Al2O3-(W, Ti)C ceramic tools obtained through experiments. It is found that the proposed model can be used to predict the lives of the ceramic cutting tools in intermittent turning operation.
2011-07-01
Time-Dependent 2D Modeling of Magnetron Plasma Torch in Turbulent Flow
International Nuclear Information System (INIS)
A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, while the current density distribution at the anode is more concentrated with a ...
2008-06-01
The technique and preliminary results of LEU U-Mo full-size IRT type fuel testing in the MIR reactor
In March 2007 in-pile testing of LEU U-Mo full-size IRT type fuel elements was started in the MIR reactor. Four prototype fuel elements for Uzbekistan WWR SM reactor are being tested simultaneously - two of tube type design and two of pin type design. The dismountable irradiation devices were constructed for intermediate reloading and inspection of fuel elements during reactor testing. The objective of the test is to obtain the experimental results for determination of more reliable design and licensing fuel elements for conversion of the WWR SM reactor. The heat power of fuel elements is measured on-line by thermal balance method. The distribution of fission density and burn-up of uranium in the volume of elements are calculated by using the MIR reactor MCU code (Monte-Carlo) model. In this paper the design of fuel elements, the technique, main parameters and preliminary results are described. (author)
2008-07-15
Energy Technology Data Exchange (ETDEWEB)
Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are generated within the ...
1989-01-01
The effect of welding parameters on hydrogen distribution in pipeline welds
Energy Technology Data Exchange (ETDEWEB)
There is currently considerable interest in identifying and quantifying the effects of welding procedure parameters and steel composition factors on the risk of cracking in pipeline girth welds that may be experienced during winter construction. Although low ambient temperatures, that may be experienced during winter construction, are generally assumed to increase the risk of cracking there has been little work to quantify the effects and to suggest how welding procedures should be modified for winter conditions. The present work was undertaken to calculate the effects of changes in welding parameters on the thermal cycle and the diffusion of hydrogen for a typical pipeline girth weld. A simple analytical method and the finite element method (FEM) were used. Both methods gave similar results but the simple method was very sensitive to the value of heat transfer coefficient. The results showed that the relation between the hydrogen diffusion ...
1990-03-01
Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA
International Nuclear Information System (INIS)
SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various combinations of the safety systems helps to develop an event tree of SGTR accident ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
In this study, WO{sub 3} thin films were grown on glass substrates using an aqueous solution containing tungstate (NH{sub 4}){sub 2}WO{sub 4} as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at T{sub s} = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T({lambda}) and reflectance R({lambda}) spectra in 300-1800 nm domain. The ...
2009-11-13
International Nuclear Information System (INIS)
In this study, WO3 thin films were grown on glass substrates using an aqueous solution containing tungstate (NH4)2WO4 as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at Ts = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T(?) and reflectance R(?) spectra in 300-1800 nm domain. The refractive and absorption indexes, n and k were ...
2009-11-13
Structural and electronic properties of the A-15 compounds Nb{sub 3}Rh and Nb{sub 3}Ir
Energy Technology Data Exchange (ETDEWEB)
The structural and electronic properties of the A-15 compounds Nb{sub 3}Rh and Nb{sub 3}Ir were studied by means of escalar relativistic full-potential linearized augmented-plane wave (FP-LAPW) calculations with generalized gradient corrections. An investigation of the band structure of the hypothetical Nb{sub 3}Nb compound was also performed at the theoretical equilibrium lattice constant to ascertain the contribution of the nontransition elements on the B site in these A{sub 3}B-type compounds. Band structures and total densities of states were obtained. A rough estimate of the electron-phonon coupling parameter {lambda} as well as of the electronic specific-heat coefficient {gamma} were obtained for both Nb{sub 3}Rh and Nb{sub 3}Nb, which confirms that this latter is a low-temperature superconductor with T{sub c} - 10K.
2007-04-30
Space effect on liquid film flow in a BWR fuel bundle
Critical power at boiling transition is an important factor in a boiling water reactor (BWR) fuel bundle design. Boiling transition under high quality accounts for dryout as the result of the complete disappearance of film flow on a fuel rod. This liquid film vanishing process can be calculated by the liquid film model, which takes into account the evaporation due to heat from the rod surface, liquid film entrainment by steam flow, and liquid droplet deposition. It is known that spacers affect liquid film entrainment and liquid droplet deposition, so the detailed study of spacer effects on hydrodynamic characteristics is necessary for critical power prediction based on the film flow model. Many studies have been conducted to examine spacer effects on liquid film flow. However, most of them are restricted to simple test sections such as a rectangular conduit. There are a few reports on fuel bundle geometry; however the bundle studied was only a ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The PuO/sub 2/ cask or SP 5320-2 and 3 cask is designed for surface shipment of americium or plutonium. The cask design was physically tested to demonstrate that it met the criteria specified in US ERDA Manual Chapter 0529, and Chapter I, Interstate Commerce Commission. The package has been assessed for transport of up to 357 grams of plutonium (403 grams PuO/sub 2/ powder) and up to 176 grams of americium (200 grams AmO/sub 2/ powder), having a maximum decay heat of 203 watts. Criticality evaluation alone would allow the shipment as Fissile Class II but the radiation level of the cask, measured at the time of shipment, may exceed 50 mrem/h at the surface and require shipment as Fissile Class III. Sample calculations address only the more restrictive of the two materials, which in most cases is /sup 238/PuO/sub 2/.
1980-05-01
SEAFP-2 bounding accident analyses
Energy Technology Data Exchange (ETDEWEB)
Analyses have been performed of the potential consequences to the public of hypothetical loss-of-coolant accidents in conceptual fusion power plant designs. In order to establish upper bounds to the consequences of such events, a case has been studied in which total loss of all active cooling has been assumed, with no remedial intervention for the duration of the accident sequence. The analyses are based on three conceptual power plant designs, two of them similar to those assumed in the earlier safety and environmental assessment of fusion power (SEAFP) study (Raeder et al., 1995), with updating of assumed structural materials. The three models studied provide a broad range of design options. In all cases the decay-heat driven temperature transients are well below the level at which structural melting would begin. Based on conservative assumptions, mobilisation, release and dose calculations show that potential maximum doses to the public are ...
2000-09-01
International Nuclear Information System (INIS)
The relationship between the current density distribution and the electron density profile during the flat-top phase of Ohmic discharges in TEXTOR has been investigated by means of far-infrared interferometry and polarimetry. It is found that neither gradual nor rapid changes of the electron density distribution (induced by continuous gas feed or pellet injection) alter the current profile significantly. The conclusion is drawn from the temporal evolution of the measured Faraday rotation signals #alpha#_e_x_p(x,t) which are proportional to the line integrals of n_c times the poloidal magnetic field component B_p_c along the probing beam paths (x is the distance of a chord from the plasma centre). By taking into account the known variation of the density profile but keeping the current distribution fixed, theoretical signals #alpha#_s_i_m(x,t) can be calculated which match the observed waveforms very well without any need to readjust the poloidal field. Under ...
Energy Technology Data Exchange (ETDEWEB)
Petrographic research for the Nevada Nuclear Waste Storage Investigations focused on xenolithic variability in the Topopah Spring Member and on variations of clinoptilolite composition at Yucca Mountain. Zeolite and smectite occurrences were considered in terms of their relation to a disturbed zone beneath the potential repository, and mineral stability experiments have produced a new clinoptilolite structure as a result of prolonged heating at low temperature. Limitations were defined on the abundance of erionite and of sulfur. X-ray diffraction studies lead to improved analytical methods. Progress was made in the comparative study of mineralogy in sand ramps and in faults. Geological modeling considered the differences of the diffusion of nonsorbing tracers in vertically and in horizontally fractured rock. Modeling also treated the diffusion of a nonsorbing tracer in devitrified and in zeolitized rock. The results of these experiments in all cases show relatively ...
1987-10-01
International Nuclear Information System (INIS)
A series of 27 reflood experiments has been carried out in a full-length electrically heated rod bundle facility. The primary objective of these tests was to study the effects of a simultaneous upper plenum and downcomer coolant injection and to provide data for the verification of computer codes. The experimental results indicate that an upper plenum injection alone cools the test rods slowly, a simultaneous coolant injection to the downcomer improves cooling significantly, and a downcomer injection alone cools the test rod bundle best if the total value of the coolant flow rate is the same in these three different cases. If the coolant injected to the upper plenum increases the total flow rate, the quench time of the test rods decreases at all elevations. Quenching time and clad temperature histories calculated with the computer codes NORCOOL-I and FLOOD4 are in a reasonable quantitative agreement with experiments in the case of pure ...
1983-02-01
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected radiosity field for the ...
1989-03-01
Probabilistic power generation planning with environmental consideration for Lebanon
International Nuclear Information System (INIS)
Full text.This paper describes a software tool for generation expansion planning based on dynamic programming, probabilistic production simulation, and environmental assessment. The aim is to determine the units needed to expand a given system in order to minimize either the cost or the environmental impact or some weighed function of the two. The problem of generation expansion planning is solved in stages using Tunnel Dynamic Programming (TDP) with Heuristic rules to limit the number of options analyzed. The production costing methodology is based on combining a probabilistic generation model known as the capacity outage table (COT) with the load duration curve (LDC) of the system to deduce a risk model from which the expected energy not supplied (EENS) is estimated. The generation model is built recursively using an efficient numerical convolution procedure and is combined at each step with the LDC to calculate the expected energy produced by each unit, its ...
2000-11-23
Energy Technology Data Exchange (ETDEWEB)
Airborne pollutants can cause failures in switching and computing equipment. This paper focuses on a subset of such pollutants - airborne fine particles (<2.5 [mu]m diameter). It begins by examining the extent to which different improvements in heating, ventilating and air conditioning (HVAC) systems reduce indoor concentrations of fine particles. For each modification, the consequent reduction in soiling rate is derived. The concomitant increase in operating costs is also calculated. These costs are then compared with the costs of failures in telephone switching offices, leading to estimates of failure rate reductions that would make improvements cost-effective. Finally, the reduction in failures required to offset the costs of the improvements are compared with documented differences in failure rates between unimproved and improved environments. This study suggests that, in many telephone switching offices, the added operating costs ...
1991-01-01
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
2001-06-17
Modeling the internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
A mathematical model was developed to predict the penetration of a transient fuel spray, the temporal and spatial distribution of air-fuel mixture before the end of ignition delay and the subsequent pressure rise during combustion in a Direct-Injection Diesel Engine with and without swirl. The model accounts for the non-isothermal and non-isobaric character of processes during fuel injection resulting from continuous motion of the piston. The effects of various engine operating variables on spray were studied and graphically presented. The calculated spray penetration with and without crossflow of air is compared with the available experimental data of other researchers with good agreement. The model can predict the rate of combustible-mixture formation, the rate of heat release and cylinder pressure as a function of time in direct injection (DI) diesel engine. A single-cylinder D.I. research diesel engine was operated with N-hexadecane as the ...
1988-01-30
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water production is found to ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water production is found to ...
2006-03-01
Laser-assisted solar cell metallization processing. Quarterly report, March 13-June 12, 1984
Energy Technology Data Exchange (ETDEWEB)
Laser-assisted processing techniques, utilized to produce fine, metal grid patterns for high-efficiency solar cells, are being investigated, developed, and characterized. The work performed in the third quarter of this contract is detailed here. A preliminary economic evaluation has yielded the conclusion that laser-assisted pyrolysis of spun-on silver neodecanoate is the most promising of all the metallization techniques being investigated in this contract. Early adhesion problems have been solved by optimizing deposition parameters. Linewidth studies have been carried out as a function of laser power, scan speed, and film thickness. Preliminary solar cells have been fabricated and characterized using this metallization scheme. Silver neodecanoate films have also been decomposed using a pulsed uv laser and metal mask. A detailed study of the various models of localized surface temperature rise in silicon due to laser heating has been carried out. A review of this ...
1984-08-20
Knight shift in the superconducting state of several vanadium based A-15 compounds
International Nuclear Information System (INIS)
The resonance line shift of a series of A-15 structures (V_3Pt, Vsub(0.76)Ptsub(0.24) and Vsub(0.62)Irsub(0.38) is measured as a function of temperature in the superconducting state. A method will be described to separate the contribution of the diamagnetism of the superconductor (Meissner effect) and that of the Knight shift to this line shift. From the temperature dependence of the Knight shift of the V atoms the sum of the s and d contribution to the Knight shift can be determined. In these three compounds the s and d contributions appear to cancel out nearly. Moreover the temperature dependence of kappa_2 can be calculated from the measurements. The values of kappa_2 extrapolated at T=Tsub(c) are about 70 for these samples. From the obtained sum of Ksub(s) and Ksub(d) and the data of the susceptibility or of the specific heat of these samples Ksub(s) and Ksub(d) can be separated. For all samples Ksub(s)=0.06+-0.005%. Finally it was observed ...
Energy Technology Data Exchange (ETDEWEB)
Anisotropy finite element analysis was performed to study stresses associated with the tetragonal precipitates and the tetragonal to monoclinic transformation in MgO partially stabilized zirconia. Stresses were assumed to be caused by the lattice misfits between the product phase and the parent phase. In the finite element calculations, the tetragonal and monoclinic precipitates were assumed to be lenticular in shape, and the anisotropic elastic constants of the cubic, tetragonal and monoclinic phases were considered. The purpose of this paper is to obtain some knowledge about how stresses respond when the microstructure is changed, and how stress fields affect microstructure development. The finite element results show that increasing a{sub t}/a{sub c} and decreasing c{sub t}/a{sub c} can create a favorable stress field to reduce the growth rate of tetragonal precipitates during the heat treatment. Stresses associated with the single ...
1999-11-30
Feasibility of an antiproton catalyzed fission fragment rocket
Energy Technology Data Exchange (ETDEWEB)
The purpose of this project was to investigate the feasibility of an antiproton catalyzed fission fragment rocket (FFR). The FFR is characterized by the extraction of fission fragments from the fissile fuel, and the utilization of their kinetic energy for thrust generation. A significant drawback to previous FFR designs was the requirement to maintain a critical nuclear pile as the fission fragment source. The author examined the possibility of replacing the critical pile with a sub-critical pile driven by antiprotons. Recent experiments have revealed that antiprotons stimulate highly energetic fissions in {sup 238}U, with a neutron multiplicity of 13.7 neutrons per fission. This interaction was used as a throttled neutron source. The pile consisted of layers of fissile coated fibers which are designed to allow fission fragments to escape them, where the fragments collide with a fluid. The heated fluid is then ejected from the rocket to provide thrust. The ...
1992-03-01
Experiments with the HORUS-II test facility
Energy Technology Data Exchange (ETDEWEB)
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests ...
1997-12-31
Development of magnetic drive packless valves for commercial purpose
Energy Technology Data Exchange (ETDEWEB)
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve and ...
1995-09-01
Coal quality engineering analysis aids plant performance
Energy Technology Data Exchange (ETDEWEB)
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant operations may be improved is discussed. 7 ...
1988-10-01
Energy Technology Data Exchange (ETDEWEB)
The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of ...
1987-03-01
International Nuclear Information System (INIS)
The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of ...
1987-01-01
International Nuclear Information System (INIS)
There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-III experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor coolant system, and void fraction distributions on the primary side ...
1992-04-01
International Nuclear Information System (INIS)
There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-HI experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho-National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor coolant system, and void fraction distributions on the primary side ...
1991-10-28
The bright star 55 Cancri is known to host five planets, including a transiting super-Earth. The interferometric study presented here yields directly determined values for 55 Cnc's stellar astrophyiscal parameters: $R=0.943 \\pm 0.010 R_{\\odot}$, $T_{\\rm EFF} = 5196 \\pm 24$ K. We use isochrone fitting to determine 55 Cnc's age to be 10.2 $\\pm$ 2.5 Gyr, implying a stellar mass of $0.905 \\pm 0.015 M_{\\odot}$. Our analysis of the location and extent of the system's habitable zone (0.67--1.32 AU) shows that planet f ($M \\sin i = 0.155 M_{Jupiter}$) spends the majority of the duration of its elliptical orbit in the circumstellar habitable zone, where, with moderate greenhouse heating, it could harbor liquid water. Finally, our direct value for 55 Cancri's stellar radius allows for a model-independent calculation of the physical diameter of the transiting super-Earth 55 Cnc e ($\\sim 2.05 \\pm 0.15 R_{\\earth}$), which, depending on the ...
2011-01-01
Simulation of sludge deposit onto a 900 MW steam generator tubesheet with the 3D code GENEPI
Energy Technology Data Exchange (ETDEWEB)
Heat transfer processes use fluids which are generally not pure and can react with transfer surfaces. These surfaces are subject to deposits which can be sediments harmful to heat transfer and to integrity of materials. For nuclear plant steam generators, sludge build-up accelerates secondary side corrosion by concentrating chemical species. A major safety problem involved with such a corrosion is the growing of circumferential cracks which are very difficult to detect and size with eddy current probes. With a view to understand and control this problem, it is necessary to develop a mathematical model for the prediction of sludge behavior in PWR steam generators. Based on fundamental principles, this work intends to use different models available in literature for the prediction of the phenomenon leading to the accumulation of sludge particles at the bottom (the tubesheet) of a PWR. For that, a three-dimensional simulation of magnetite ...
1998-07-01
Thermal fatigue of HIPed W/Cr-bronze divertor small scale mock-ups
International Nuclear Information System (INIS)
Thermal fatigue is one of the key factors governing the lifetime of the divertor plate. Tungsten is a promising candidate to cover the surface of the divertor plate in the design of the international thermonuclear experimental reactor (ITER). The W/Cr-bronze divertor small scale mock-ups were manufactured by hot isostatic pressing (HIPing) technique. Thermal fatigue tests of W/Cr-bronze divertor mock-ups have been carried out by an electron beam facility. The mock-ups were tested under a cyclic surface heat flux of 9 MW m"-"2 for 1000 cycles. The electron beam was loaded on the mock-up surface for 20 s and unloaded for 20 s, alternately. The flow rate of water coolant was 0.1 L s"-"1. The 0.3 mm diameter NiCr-NiSi thermocouples were used to monitor the temperature distribution of the mock-up. It was found that the maximum temperature of the tungsten surface was about 400 degree sign C. The saturated temperature at the joint of tungsten and Cr-bronze was 160 degree ...
2004-11-15
Energy Technology Data Exchange (ETDEWEB)
The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue Verfahren zur wahlweisen Zuschaltung ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
The research project's objective is to create a decision help for owners of residential buildings for several families regarding the renewal of decentralized heating and warm water preparation systems in the flats. The focus lies on a comparison of the costs of typical systems on the basis of a full cost calculation. This is done by taking into consideration the intentions of residential building companies like the reduction of additional costs to be paid by the tenants (both for social reasons and to make the flats easier to rent), low investment costs, low maintenance costs, energy saving, tenants' claims for comfort and acceptance by the tenants, economical reasons, especially regarding flats fully amortized (activation in the balance sheet). In addition to the quantitative comparison, the advantages and disadvantages of the different systems were also compared to one another from the qualitative point of view. [German] ...
2004-04-01
Simulation and Observation of Acoustic-Gravity Waves in the Ionosphere
Atmospheric and ionospheric perturbations associated with the acoustic-gravity waves (AGW) with typical frequencies of a few hertz -millihertz are considered. These events may be caused by the influence from space and atmosphere as well as by oscillations of the Earth surface and other near-surface phenomena. The surface sources include long-period oscillations of the Earth's surface, earthquakes, explosions, thermal heating, seisches and tsunami waves. The wavelike phenomena manifest themself as travelling disturbances of air (in the atmosphere) and of electron density (in the ionosphere). Travelling ionospheric disturbances (TIDs) are well detected by radio physical methods. AGW generation by near-surface sources is modeled by the numerical solution of the equation of geophysical fluid dynamics for different sources in two-dimensional non-linear dissipative compressible atmosphere. The numerical calculations are based on the FCT (Flux ...
2010-01-01
Screening Criteria for Loss of Room Cooling Failure
Energy Technology Data Exchange (ETDEWEB)
In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. Even though we ...
2007-01-15
Geothermal Heat Pump Profitability in Energy Services
Energy Technology Data Exchange (ETDEWEB)
If geothermal heat pumps (GHPs) are to make a significant mark in the market, we believe that it will be through energy service pricing contracts offered by retailcos. The benefits of GHPs are ideally suited to energy service pricing (ESP) contractual arrangements; however, few retailcos are thoroughly familiar with the benefits of GHPs. Many of the same barriers that have prevented GHPs from reaching their full potential in the current market environment remain in place for retailcos. A lack of awareness, concerns over the actual efficiencies of GHPs, perceptions of extremely high first costs, unknown records for maintenance costs, etc. have all contributed to limited adoption of GHP technology. These same factors are of concern to retailcos as they contemplate long term customer contracts. The central focus of this project was the creation of models, using actual GHP operating data and the experience of seasoned professionals, to simulate the financial ...
1997-11-01
Gas turbine applications in the drying industry
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to determine if it is feasible to utilize the hot exhaust gas discharged from gas turbines in direct applications. This report illustrates the technical feasibility and economic viability of using gas turbines in drying applications. The size of turbines in this investigation ranges from 2 MW to 10 MW. In addition, an implementation strategy has been developed to employ this new system. The method used to structure the scope of this undertaking is as follows: Step 1. Collecting information by contacting dryer manufacturer and companies drying different products. Information was also gathered by literature studies and the internet. Thomas register is a great tool when it comes to company and market searches. Step 2. Looking into if it is technically possible to use the exhaust gas directly into dryers. The parameters needed for these calculations were gathered in step 1, and some of the more important are temperature, mass flow, ...
2000-07-01
Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report
Energy Technology Data Exchange (ETDEWEB)
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between cable pipes ...
1984-07-01
Energy Technology Data Exchange (ETDEWEB)
Organic Rankine cycles (ORC) have unique properties that are well suited to solar power generation. In this work design and performance calculations are performed using MatLab/SimuLink computational environment. The cycle consists of thermal solar collectors (Flat Plate Solar Collector (FPC), or Parabolic Trough Collector (PTC), or Compound Parabolic Concentrator (CPC)) for heat input, expansion turbine for work output, condenser unit for heat rejection, pump unit, and Reverse Osmosis (RO) unit. Reverse osmosis unit specifications used in this work is based on Sharm El-Shiekh RO desalination plant. Different working fluids such as: butane, isobutane, propane, R134a, R152a, R245ca, and R245fa are examined for FPC. R113, R123, hexane, and pentane are investigated for CPC. Dodecane, nonane, octane, and toluene are allocated for PTC. The proposed process units are modeled and show a good validity with literatures. Exergy and ...
2010-11-15
Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre
Energy Technology Data Exchange (ETDEWEB)
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of monitoring (temperature, ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The molar heat capacities (C{sub p,m}) of crystalline potassium dichromate (K{sub 2}Cr{sub 2}O{sub 7} (cr)) and aqueous K{sub 2}Cr{sub 2}O{sub 7} solution (0.1699 mol.kg{sup -1}) were measured in the temperature range from 100 to 390 K and from 80 to 370 K by an automatic adiabatic calorimeter equipped with a small cell of internal volume of 6 cm{sup 3}, respectively. No phase transition took place in the temperature range from 100 to 390 K for K{sub 2}Cr{sub 2}O{sub 7} (cr). The relationships of C{sub p,m} of K{sub 2}Cr{sub 2}O{sub 7} (cr) with respect to T were established to be C{sub p,m} 177.53 + 161.92 X - 138.14 X{sup 2} - 209.67 X{sup 3} + 160.35 X{sup 4} + 137.44 X{sup 5} - 41.291 X{sup 6} and C{sub p,m} 177.52 + 171.66 X -149.59 X{sup 2} - 246.17 X{sup 3} + 194.79 X{sup 4} + 167.30 X{sup 5} - 64.368 X{sup 6} (X=(T-245.00)/145.00) for Series 1 and Series 2 experiments, respectively. No phase transition took place for the solution from 80 to 270 K. The ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
A heat pump was tested in the cooling mode under the following conditions: (1) a steady-state test with 95/sup 0/F (35/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (2) a steady-state test with 82/sup 0/F (27.8/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (3) a cyclic test with an outdoor room temperature of 82/sup 0/F (27.8/sup 0/C), various indoor conditions, and a dry indoor coil. The indoor conditions were varied as follows: (1) indoor temperatures of 75/sup 0/F (23.9/sup 0/C), 80/sup 0/F (26.7/sup 0/C) and 85/sup 0/F (29.4/sup 0/C); (2) volume flowrates over the evaporator coil of 880 cfm (0.47 m/sup 3//s), 1100 cfm (0.52 m/sup 3//s) and 1425 cfm (0.67 m/sup 3//s); (3) during the off-time the dampers were closed in one test series and kept open with a continuously running air handling fan in another test series; (4) the on and off times of the heat pump during the cyclic ...
1982-05-01
Interaction of antimicrobial peptides with lipid membranes
International Nuclear Information System (INIS)
This study aims to investigate the difference in the interaction of antimicrobial peptides with two classes of zwitterionic peptides, phosphatidylethanolamines (PE) and phosphatidylcholines (PC). Further experiments were performed on model membranes prepared from specific bacterial lipids, lipopolysaccharides (LPS) isolated from Salmonella minnesota. The structure of the lipid-peptide aqueous dispersions was studied by small-and wide-angle X-ray diffraction during heating and cooling from 5 to 85 C. The lipids and peptides were mixed at lipid-to-peptide ratios 10-10000 (POPE and POPC) or 2-50 (LPS). All experiments were performed at synchrotron soft condensed matter beamline A2 in Hasylab at Desy in Hamburg, Germany. The phases were identified and the lattice parameters were calculated. Alamethicin and melittin interact in similar ways with the lipids. Pure POPC forms only lamellar phases. POPE forms lamellar phases at low temperatures that ...
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This extrapolation procedure, ...
1976-01-01
Reducing indoor air formaldehyde concentrations
Energy Technology Data Exchange (ETDEWEB)
Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission significantly, and UF-bonded wood products are ...
1985-08-01
Energy Technology Data Exchange (ETDEWEB)
Chloride-induced pitting corrosion of stainless steel (Materials No. 1.4301 and 1.4571) was investigated with the aid of chronopotentiostatic tests. Oxide films upon the surface (temper colours), addition of inhibitors (sulphate and nitrate) and temperature were the testing variables. Two different critical pitting potentials have been found, which give information on the potential ranges for stable passivity, latent and stable pitting corrosion. The results only indicate a small effect of Mo content of the material and test temperature. The inhibitors (sulphate and nitrate) have a marked effect. Specimens with a clean surface produced by pickling are markedly more resistant against pitting corrosion than specimens with a yellow temper colour, whereas the difference in corrosion resistance between yellow and blue films is relatively small. The width of the critical potential range for pitting corrosion generally increases with increasing oxide film thickness. ...
1993-09-01
Examination of measurement invariance provides a powerful method to evaluate the hypothesis that the same set of psychological constructs underlies a set of test scores in different populations. If measurement invariance is observed, then the same psychological meaning can be ascribed to scores in both populations. In this study, the measurement model including core and supplementary subtests of the Wechsler Adult Intelligence Scale-Fourth edition (WAIS-IV) were compared across the U.S. and Canadian standardization samples. Populations were compared on the 15 subtest version of the test in people aged 70 and younger and on the 12 subtest version in people aged 70 or older. Results indicated that a slightly modified version of the four-factor model reported in the WAIS-IV technical manual provided the best fit in both populations and in both age groups. The null hypothesis of measurement invariance across populations was not rejected, and the results provide direct evidence for the ...
2011-06-01
Association study of SNAP25 and schizophrenia in Irish family and case-control samples.
SNAP25 occurs on chromosome 20p12.2, which has been linked to schizophrenia in some samples, and recently linked to latent classes of psychotic illness in our sample. SNAP25 is crucial to synaptic functioning, may be involved in axonal growth and dendritic sprouting, and its expression may be decreased in schizophrenia. We genotyped 18 haplotype-tagging SNPs in SNAP25 in a sample of 270 Irish high-density families. Single marker and haplotype analyses were performed in FBAT and PDT. We adjusted for multiple testing by computing q values. Association was followed up in an independent sample of 657 cases and 411 controls. We tested for allelic effects on the clinical phenotype by using the method of sequential addition and 5 factor-derived scores of the OPCRIT. Nine of 18 SNPs had P values Irish family sample. Although we failed to replicate this in an independent sample, this gene should be further tested in other samples. PMID:19806613
2010-03-01
International Nuclear Information System (INIS)
A case study is presented where an integrated, ecologically relevant exposure assessment is presented for a polluted lowland river. Using partial least squares regression of latent structures (PLS), an analysis of the impact of two effluents on physico-chemical water quality measures, macroinvertebrate and diatom communities, and in situ bioassay responses with four different test species are combined into an integrative exposure assessment. Bioassays focussed on growth and condition related endpoints, because they are key functional processes of organisms and populations. Integrating these multiple lines of evidence, we were able to discriminate among the impact of both effluents, link changes in physico-chemical water quality with bioassay endpoints and ecological quality of the ecosystem, and address the importance of integrating all information into one exposure assessment framework. The bioassays under field conditions indicated that most endpoints measured ...
2004-11-01
The role of large-scale, extratropical dynamics in climate change
Energy Technology Data Exchange (ETDEWEB)
The climate modeling community has focused recently on improving our understanding of certain processes, such as cloud feedbacks and ocean circulation, that are deemed critical to climate-change prediction. Although attention to such processes is warranted, emphasis on these areas has diminished a general appreciation of the role played by the large-scale dynamics of the extratropical atmosphere. Lack of interest in extratropical dynamics may reflect the assumption that these dynamical processes are a non-problem as far as climate modeling is concerned, since general circulation models (GCMs) calculate motions on this scale from first principles. Nevertheless, serious shortcomings in our ability to understand and simulate large-scale dynamics exist. Partly due to a paucity of standard GCM diagnostic calculations of large-scale motions and their transports of heat, momentum, potential vorticity, and moisture, a comprehensive ...
1994-02-01
Technical development of double-clad process for thin strip casting of carbon steel
Energy Technology Data Exchange (ETDEWEB)
This report documents the technical development for a patent disclosure of a double-clad process for the continuous casting of thin-strip carbon steel. The fundamental idea of the disclosure is to form a product strip by depositing molten steel between two, cooled, clad strips of the same material. The claimed benefits include: (a) the conservation of energy in steel making through the elimination of soaking pits and reheat cycles, and (b) an improved surface on both sides of the as-cast product such that it will be suitable for direct feed to a cold-reduction mill. However, the process as conceived is not necessarily limited to the casting of carbon steel, but may be also applied to other metals and alloys. The work is described under three headings as follows. Preliminary Considerations and Scoping Analysis presents the basic idea of the double-clad, thin-strip casting process; the energy conservation potential; scoping heat transfer ...
1984-08-01
Simulation of natural convection cooling phenomena for research reactors using the code PARET
International Nuclear Information System (INIS)
This study deals with testing the capacity of the code PARET to simulate natural circulation phenomena under different boundary conditions in addition to assessment of some new options related to simulation of control rod movement and the reactivity effect of thermal expansion fuel elements. the experiments of the simple thermal hydraulic loop of Missouri University about natural circulation phenomena in narrow parallel channel were used to validate the code. The results indicate good agreements regarding the evolution of coolant velocity and clad temperature. In particular the heat transfer coefficient of natural convection has been calculated in good agreement with the experiment. On the other hand, the core of MNSR reactor has been modelled to stimulate the reactor dynamic behaviour under natural circulation condition for different initial power level. The observed oscillations during the initial phase vanish gradually with passing time. In ...
International Nuclear Information System (INIS)
The results of calculational comparative study into radiotoxicity and residual power release time dependences for spent uranium-plutonium and thorium-uranium nuclear fuels from the WWER-1000 reactors during ling- time (up to 300 thousand years) storage are discussed. It is shown that the total radiotoxicities for actinides from uranium, uranium-plutonium and thorium-uranium spent fuels at storage period begin amount to 5.2 x 10"1"4, 1.3 x 10"1"5 and 1.5 x 10"1"4 kg of water per 1 t of discharged fuel, respectively. Radiotoxicity of actinides in uranium-plutonium fuel is revealed to be by the factor of 2.5 greater than that for ordinary uranium fuel because of greater accumulation of "2"3"9Pu, "2"4"0Pu, "2"4"1Pu and "2"4"4Cm. Radiotoxicity of actinides for thorium-uranium fuel calculated taking into account "2"3"4U is estimated to be by the factor 3.5 smaller than that for uranium fuel. The residual power releases for actinides from uranium, ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
The performance of the Magma Power Company's reinjection well No. 46-7 at East Mesa has been examined. Water was cooled to 100/sup 0/F(+-) to simulate total heat extraction and then tested using membrane filter flow procedures. The cooled water contains particles which are in the high colloid size range, and formation impairment by these particles is unlikely. There is evidence that acid soluble corrosion products and calcium compounds constitute about two thirds of the particulates, and that the acid insoluble residue contains precipitated silica, insoluble corrosion products, and possibly formation fines carried in the produced water. Under stabilized conditions, the suspended solids content of the water is less than 2 parts per million. However, during the frequent production well start ups, a higher concentration of suspended solids is carried in the produced water and into the injection well, conceivably augmenting fill in the injector. But most ...
1980-02-01
Hitch code capabilities for modeling AVT chemistry
International Nuclear Information System (INIS)
Several types of corrosion have damaged alloy 600 tubing in the secondary side of steam generators. The types of corrosion include wastage, denting, intergranular attack, stress corrosion, erosion-corrosion, etc. The environments which cause attack may originate from leaks of cooling water into the condensate, etc. When the contaminated feedwater is pumped into the generator, the impurities may concentrate first 200 to 400 fold in the bulk water, depending on the blowdown, and then further to saturation and dryness in heated tube support plate crevices. Characterization of local solution chemistries is the first step to predict and correct the type of corrosion that can occur. The pH is of particular importance because it is a major factor governing the rate of corrosion reactions. The pH of a solution at high temperature is not the same as the ambient temperature, since ionic dissociation constants, solubility and solubility products, activity coefficients, etc., ...
1985-03-01
Heavy fuel oil combustion in a cylindrical laboratory furnace: measurements and modeling
Energy Technology Data Exchange (ETDEWEB)
The finite-volume based commercial CFD-code Fluent was used to simulate the reacting flow in a heavy fuel oil fired laboratory furnace. Both the standard {kappa}-{epsilon} turbulence model and the Reynolds stress model (RSM) were tested. The combustion model was based on the conserved scalar (mixture fraction) and prescribed probability density function approach. The heavy fuel oil droplet trajectories were predicted by solving the momentum equations for the droplets using the Lagrangian treatment. The soot distribution in the furnace was calculated by solving a transport equation for the soot mass fraction. Simple expressions for the soot formation and oxidation rates were employed. The radiation heat transfer equation was solved using the finite volume method. The formation of thermal NO from molecular nitrogen was modeled according to the extended Zeldovich mechanism. Fuel-based NO was modeled assuming that all the nitrogen in the fuel is ...
2005-03-01
Energy Technology Data Exchange (ETDEWEB)
Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling ...
1995-01-01
C-14 release and transport from a nuclear waste repository in an unsaturated medium
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to ...
1990-06-01
Aerosol deposition in horizontal steam generator tubes in severe accident conditions
Energy Technology Data Exchange (ETDEWEB)
The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the ...
2003-07-01
Aerosol deposition in horizontal steam generator tubes in severe accident conditions
International Nuclear Information System (INIS)
The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree well with the ...
2003-10-05
In the Loop : A look at Manitoba's geothermal heat pump industry
International Nuclear Information System (INIS)
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...
A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath
International Nuclear Information System (INIS)
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large ...
2003-11-28
Calculating plume rise above level of stack
Energy Technology Data Exchange (ETDEWEB)
A method for calculating plume rise above stack level is presented. The equations set forth by Briggs, which are presently the most popular for such calculations, are discussed. A method using 2 nomographs, simplifying the calculations is given. (JMT)
1982-04-01
Renewable energy technologies for federal facilities: Geothermal heat pump
Energy Technology Data Exchange (ETDEWEB)
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
1996-05-01
Performance of a commercial heat pipe under operational conditions
Energy Technology Data Exchange (ETDEWEB)
The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.
1983-04-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning industrial uses and design of microwave heating equipment. Included are heating and drying of paper, industrial process heat, vulcanization, textile processing, metallurgical heat for sintering and ceramic manufacturing, food processing, and curing of polymers.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
1995-12-01
Heating and hot water: the installations; Chauffage et eau chaude: les installations
Energy Technology Data Exchange (ETDEWEB)
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.
1999-07-01
Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
1992-02-01
Convective heat transfer in annular flow
International Nuclear Information System (INIS)
Several aspects of heat transfer at the annular two phase flow regime are considered. Nucleate boiling is supposed to be absent. Theoretical solutions for cases of laminar and turbulent flow in the liquid film, respectively, are considered, when steam presence does not effect the heat transfer. Heat transfer in annular flows is also considered, where steam phase consists totally or partially of the so-called incondensable gas. In this case steam phase can be a considerable resistance to heat transfer.
1980-01-01
Verification of the CFD code FLUENT by post test calculation of ROCOM experiments
International Nuclear Information System (INIS)
Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory ...
2005-10-02
Transport in a toroidally confined pure electron plasma
International Nuclear Information System (INIS)
O close-quote Neil and Smith [T.M. O close-quote Neil and R.A. Smith, Phys. Plasmas 1, 8 (1994)] have argued that a pure electron plasma can be confined stably in a toroidal magnetic field configuration. This paper shows that the toroidal curvature of the magnetic field of necessity causes slow cross-field transport. The transport mechanism is similar to magnetic pumping and may be understood by considering a single flux tube of plasma. As the flux tube of plasma undergoes poloidal ExB drift rotation about the center of the plasma, the length of the flux tube and the magnetic field strength within the flux tube oscillate, and this produces corresponding oscillations in T_p_a_r_a_l_l_e_l and T_p_e_r_p_e_n_d_i_c_u_l_a_r. The collisional relaxation of T_p_a_r_a_l_l_e_l toward T_p_e_r_p_e_n_d_i_c_u_l_a_r produces a slow dissipation of electrostatic energy into heat and a consequent expansion (cross-field transport) of the plasma. In the limit where the cross section of ...
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Different to the very simple class of homogeneous non-equilibrium models (HEM) an one dimensional thermal-hydraulic theoretical drift-flux based and thus non-homogeneous coolant channel model and, as a result, an in itself complete thermal-hydraulic coolant channel module CCM have been established allowing to simulate in a very general way the steady state and transient behaviour of the most important parameters of a single- or two-phase fluid flowing within any type of heated or non-heated coolant channel (with an eventually varying cross flow area). To avoid mathematical discontinuities at the transition from single- to two-phase flow the coolant channel will, in its general form, be split into different regions, i.e. be looked as a basic channel (BC) which can consist of a number of different flow regimes and can, accordingly, be subdivided into a number of sub-channels (SC-s). All of them belong, obviously, ...
2005-07-01
Theoretical Calculation of Jet Fuel Thermochemistry
High-level ab initio calculations have been performed on the exo and endo isomers of gas-phase
2010-01-01
Thermal energy considerations on solar cavity wall building
Energy Technology Data Exchange (ETDEWEB)
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
1983-02-01
Recovering heat from the cupola stack
Energy Technology Data Exchange (ETDEWEB)
A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).
1986-01-01
Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM
The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)
1982-06-30
Mushy state forming of magnesium alloy making use of resistance heating
Energy Technology Data Exchange (ETDEWEB)
Feasibility of mushy state forming of magnesium alloys making use of resistance heating was examined. Magnesium alloys, AZ31, AZ61 and AZ91, were taken up as experimental materials and cylindrical billets with a diameter of 15 mm and a height of 20 mm were used for both resistance heating and forming experiments. Input heat control was applied to the billet heating and insertion of thin discs of austenitic stainless steel with a low thermal conductivity between the billet and copper electrodes was attempted in order to improve the efficiency of the billet heating. Results were summarized as follows. (1) Resistance heating by input heat control was successful to heat the billets to their respective mushy state. (2) Insertion of the discs was very helpful in heating the billets and realized the ...
2003-07-01
The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall decreases slightly with increasing wall ...
1992-10-01
Heat Transfer Augmentation in Turbulent Impinging Jets.
Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...
1979-01-01
In this paper, the authors first describe a fourth order accurate finite difference discretization for both the Laplace equation and the heat equation with Dirichlet boundary conditions on irregular domains. In the case of the heat equation, they use an i...
2004-01-01
Environmental and yield aspects of heat provision
International Nuclear Information System (INIS)
The advantages of district heating as an environmental-friendly and energy-saving technique are reviewed. The role of district heating as part of the Dutch national plan to reduce the emission of acidification and greenhouse gases by respectively 50 and 25 percent is clarified. 12 Tabs. (A.S.).
1994-01-01
UK PubMed Central (United Kingdom)
In heat-shocked tomato cell cultures, cytoplasmic heat shock granules (HSGs) are tightly associated with a specific subset of mRNAs coding mainly for the untranslated control proteins. This messenger...Full Text Available
1989-03-01
?Activation of the mitogen-activated protein kinase pathways by heat shock
UK PubMed Central (United Kingdom)
In addition to inducing new transcriptional activities that lead within a few hours to the accumulation of heat shock proteins (Hsps), heat shock activates within minutes the major signaling transduction...Full Text Available
2002-04-01
Thermodynamic analysis of a hybrid geothermal heat pump system
British Library Electronic Table of Contents (United Kingdom)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
2011-01-01
The study of thermal characteristics of high temperature oven for atomic spectroscopy
International Nuclear Information System (INIS)
We present a high temperature heat oven with merits of conventional heat pipe oven and study ots thermal characteristics. The oven consists of stainless steel body and heating part of three layers of ceramic tubes. We obtained the maximum temperature of about 1350. deg. C at the center which was measured by thermocouple and infrared thermometer. And we compared the heating characteristics in the cases of external heating and no extent heating. It was applied to self diffraction experiment in the samarium gas which was one of the high melting point material.
1997-11-01
Perturbation solution to heat conduction in melting or solidification with heat generation
The Stefan problem involving a source term is considered in this technical note. As an example, planar solidification with time-dependent heat generation in a semi-infinite plane is solved by use of a perturbation technique. The perturbation solution is validated by reducing the problem to the case without heat generation whose exact solution is available. An application to the case with constant heat generation is presented, for which a closed-form solution is obtained. The effects of heat generation and Stefan number on the evolution of solidification are examined using the perturbation solution.
2010-04-01
Geothermal heat pump applications: Industrial/commercial
Energy Technology Data Exchange (ETDEWEB)
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
1999-07-01
Workability and Heat Treatment Characteristics of Beta ...
... Accession Number : ADD135317. Title : Workability and Heat Treatment Characteristics of Beta Titanium Alloy, Ti-15V-3Cr-3Sn-3Al,. ...
1986-04-01
Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems
Energy Technology Data Exchange (ETDEWEB)
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
2006-03-01
International Nuclear Information System (INIS)
The problem of fast wave plasma heating in reactor-torsatron at the ICRF range in scenarios, optimal for fusion reactor, is numerically studied.
2006-01-01
Subcooled Flow Boiling in a Minichannel
British Library Electronic Table of Contents (United Kingdom)
It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...
2011-01-01
Rural residential application of geothermal heat pump. Progress report
Energy Technology Data Exchange (ETDEWEB)
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
1981-07-20
PROCEEDINGS OF THE 1966 HEAT TRANSFER AND FLUID ...
... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...
NASA Technical Paper 3487 ... - NASA Technical Reports Server
heat transfer augmentation was found to increase with decreasing length scale but no optimum length scale was found. Heat transfer augmentation due to turbu- ...
Metal Foam Heat Exchangers for Heat Transfer Augmentation from a Cylinder in Cross-Flow
British Library Electronic Table of Contents (United Kingdom)
A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan?s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heat exchanger to observe much higher heat transfer rate with reasonab...
2011-01-01
Long-term storage of solar heat
Energy Technology Data Exchange (ETDEWEB)
Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
A numerical analysis is made of the unsteady flow and heat transfer characteristics of mixed convection in a vertical block-heated channel with and without installing an inclined plate above an upstream block. Parameter studies including the inclined plate angle, Reynolds number (ranging from 260 to 530), and Grashof number (in the range of 0--3,200,000) on heat transfer performance have been explored in detail. The results show that the installation of an inclined plate in the vertical block-heated channel can effectively augment the blocks` heat transfer performance in the channel. This can be applied to heat exchangers.
1998-02-06
Glass-heat-pipe evacuated-tube solar collector
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
1981-08-06
Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters
1987-03-01
Forced convective heat transfer in cross-corrugated solar air heaters
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local ...
1994-11-01
Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
1981-02-10
International Nuclear Information System (INIS)
The molar heat capacities of chloroform, dichloromethane, methanol, acetonitrile, acetone, dimethyl sulfoxide, benzene, dimethylformamide, toluene, and cyclohexane, as well as their deuterated isotopologues, were measured using a multi-channel heat conduction TAM (Thermal Activity Monitor) III microcalorimeter. In addition, the apparent molar heat capacities of some of the associated dilute aqueous solutions (0.0039 i < 0.0210) were also measured. A temperature drop method from (298.15 to 297.15) K at 0.1 MPa was employed. The corresponding heat capacities were determined from the integration of the measured heat flow. The heat capacity results are shown to be in good to very good agreement with the available literature values. In addition, good correlations were obtained for the effect of isotopic substitution on both molar heat capacity ...
2008-11-01
DEPLOYABLE HEAT PDPE RADUATOR - NASA Technical Report Server (NTRS)
Eninger, J. E.: "Menisci Coalesence as a Mechanism for Venting Noncondensible. Gas From Heat-Pipe Arteries", AIAA Paper No. 74-748. ...
Analysis of Rough Wall Turbulent Heating with Application to ...
... roughness. Since T u'v' and q v'"F the heat transfer augmentation is the square root of the skin friction augmentation: - 1/2 (( St - ,Cf 0 ...
1979-01-01
TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR
Energy Technology Data Exchange (ETDEWEB)
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) ...
2010-03-01
Energy Technology Data Exchange (ETDEWEB)
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, ...
1996-12-01
Heat pumps in urban space heating systems: Energy and environmental aspects
International Nuclear Information System (INIS)
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with ...
1991-01-01
Augmentation of heat transfer in heat conductive medium by electro-hydrodynamic effect
Energy Technology Data Exchange (ETDEWEB)
A method of augmenting heat transfer in the interior of a fluid or from the interface of a solid in contact to a fluid by utilizing electro hydrodynamic (EHD) phenomena has the following advantages: the heat transfer can be effected by using a relatively small, light-weight high voltage source and some simple structural members; no vibration and noise are generated; the method has a control function to control heat transfer by adjustment of field and voltage; and this method is effective in cost-saving. It is mass transfer by the electric force caused by interaction between true charges or polarized charges in a fluid and external electric filed that plays an important role in most of such heat transfer augmentation methods by EHD. Examples of heat transfer augmentation by EHD phenomena include electricaly induced convection, contribution of EHD effect to heat ...
1988-04-20
Full potential all electron positron lifetime calculations: assessment of local enhancement factors
International Nuclear Information System (INIS)
We report the implementation of positron wave function and lifetime calculations in the all-electron full-potential linearized augmented plane wave method. Calculations of lifetimes for more than 30 materials with two different forms of the enhancement factor were done and compared to prior calculations and experiment. We find that reasonable agreement with experiment can be obtained within the local density approximation when all-electron full-potential calculations are done.
2008-04-01
Calculation of cosmic ray antiproton-proton ratio
Energy Technology Data Exchange (ETDEWEB)
Independent calculations of the antiproton-to-proton ratio by Gaisser and Maurer and by Badhwar et al. have produced conflicting results which obscure the interpretation of recent measurements of cosmic ray antiprotons. A detailed reexamination of these calculations has been performed and these differences have been resolved. We find that the first calculation was essentially correct and the reported fluxes of antiprotons are significantly higher than expected for secondary antiprotons in conventional models of cosmic ray propagation, as indicated by other recent calculations.
1982-01-15
Accelerating the convergence of self-consistent linearized augmented-plane-wave calculations
International Nuclear Information System (INIS)
The applicability of Broyden's second method for accelerating the convergence of self-consistent electronic-structure calculations based on the linearized augmented-plane-wave method is discussed in terms of a W(001) surface calculation. It is found that its use results in a significant improvement in the convergence of the calculation, and based on this it is concluded that its use should increase the size of the systems for which such calculations are feasible.
The adiabatic engine:Global developments
Energy Technology Data Exchange (ETDEWEB)
This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.
1986-01-01
Neutron star evolution with internal heating
The thermal evolution predicted by current models of the superfluid-crust interaction is noted to
1989-01-01
Geothermal heat pumps - gaining ground in the UK and worldwide
Energy Technology Data Exchange (ETDEWEB)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
2001-07-01
Geothermal heat pumps - gaining ground in the UK and worldwide
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
Energy Technology Data Exchange (ETDEWEB)
Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)
1982-12-01
Website Policies and Important Links Comments