The Container Analysis Fire Environment (CAFE) computer code has been developed to model all relevant fire physics for predicting the thermal response of massive objects engulfed in large fires. It provides realistic fire thermal boundary conditions for use in design of radioactive material packages and in risk-based transportation studies. The CAFE code can be coupled to commercial finite-element codes such as MSC PATRAN/THERMAL and ANSYS. This coupled system of codes can be used to determine the internal thermal response of finite element models of packages to a range of fire environments. This document is a user manual describing how to use the three-dimensional version of CAFE, as well as a description of CAFE input and output parameters. Since this is a user manual, only a brief theoretical description of the equations and physical models is included.
A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated ...
In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...
In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow ...
Forms used in conducting a national survey about solar energy are presented. Forms for representatives from the domestic, commercial, and industrial sectors, owners and non-owners of solar equipment, are shown. Participants were to be contacted by telephone, mail, and personal visits. (MCW)
Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common ...
A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to ...
A study was conducted to examine the energy consumption in existing and new hog farming facilities and to analyse the potential for increased natural gas use in the Saskatchewan hog industry. Existing heating/cooling, ventilation and feed mill equipment choices offer possibilities for running on electricity, natural gas or propane. Energy costs are lowest when natural gas is used. To put the study in context, an overview of the Saskatchewan hog industry was provided. The potential increase in natural gas use in hog production by year 2005 was estimated. 10 refs., 6 tabs., 8 figs.
The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current ...
Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no ...
Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet ...
The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.
Results of three-dimensional laminar and standard K-#epsilon# turbulent numerical simulations of natural convection cooling of ten cubic aluminum blocks mounted on an insulated plate, facing a shrouding wall, are presented. This geometry is chosen so that comparison with experimental results is possible. The considered problem is of great practical importance because it simulates the case of heated electronic chips, mounted on printed board assemblies, which are frequently encountered in electronic industry applications. The problem is mathematically modeled by the three-dimensional conservation differential equations of mass, momentum, energy and turbulent kinetic energy and dissipation (for the turbulent flow model). IN this paper, these equations are numerically solved by a finite volume method and the laminar and turbulent results are compared to the experimental results obtained with similar parameters.
This research investigated the inhibiting effects that sodium salts of linear monocarboxylic acids displayed towards the corrosion process of AZ31 Mg alloy in ASTM D 1387 saline solution (a synthetic industrialcooling water). The length of the aliphatic chain of the acids ranged between 7 and 15 carbon atoms. The inhibiting action of these salts can be related to the precipitation of an insoluble magnesium salt, which mainly affected the anodic reaction. The aliphatic chain length controlled the anion solubility and the reaction rate of magnesium carboxylate formation. For all the salts, an optimum concentration was experienced: 10{sup -2} M for sodium decanoate (caprate), 10{sup -3} M for sodium dodecanoate (laurate), 10{sup -4} M for sodium tetradecanoate (myristate); when this concentration was exceeded, a diminution (even a disappearance) in the inhibiting action was found. (Abstract Copyright [2009], Wiley Periodicals, Inc.)
One of the most important factors affecting the postharvest life and quality of horticultural crops is temperature. Quality loss after harvest occurs as a result of physiological and biological processes, the rates of which are influenced primarily by product temperature. As the maintenance of market quality is of vital importance to the success of the horticultural industry, it is necessary not only to cool the product but to cool it as quickly as possible after harvest. The process of precooling is the removal of field heat which arrest the deteriorative and senescence processes so as to maintain a high level of quality that ensures customer satisfaction. This paper provides a critical review to portray precooling as an intricate part of temperature management and to highlight the importance of its utilisation for extending the shelf life and maintaining the quality of horticultural products with emphasis on cut flowers. ...
The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool
Growing competitiveness of alternative manufacturing routes requires cost minimization in the production of drop forged components. The authors analyse the potential of medium carbon, vanadium microalloyed steels for drop forging. Laboratory and industrial experiments have been carried out emphasizing deformation and temperature cycles, strain rates and dwell times showing a typical processing path, associated mechanical properties and corresponding microstructures. The steels the required levels of mechanical properties on cooling after forging, eliminating subsequent heat treatment. The machinability of V-microalloyed steels is also improved when compared with plain medium carbon steels. (author)
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that ...
Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...
In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions simulating either ...
Ferritic/martensitic steel, modified 9Cr-1Mo steels have been used most extensively in the power generation industry throughout the world due to having superior high temperature properties such as high strength, creep resistance, and good microstructure stability. These steels are also the primary candidate for the RPVs(Reactor Pressure Vessels) of High Temperature Gas-Cooled Reactors. Currently, many studies has been conducted in laboratory-scale for mod. 9Cr-1Mo steels. However, there is a lack of the study on forged thick- section for RPVs. The differences in characteristics including the through thickness microstructure and mechanical properties between internal and external locations may occur during cooling after austenitization, because the thickness of RPVs is over about 200mm. Therefore, in order to use ferritic/martensitic steel as RPVs, a detailed assessment of the through thickness properties is needed. The ...
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.
... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...
In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent ...
Recently it is strongly required to reduce energy consumption to cope with the global warming. Since energy consumption in commercial and residential sectors are increasing while industrial sector is almost constant in Japan, policies to lead energy conservation in urban areas is quite important. This study aims at investigating the performance of urban energy systems which install combined heat and power (CHP) as a district heating and cooling (DHC) plant and the influence of CHP on the structure of electric power systems of utilities. The behavior of energy technologies and the possibility of energy conservation are evaluated based on an optimization model with respect to total system cost. Sensitivity analysis of population allocation into urban areas indicates that fossil fuel consumption varies in the range of 10--20% compared with conventional systems.
In the new system presented in this paper, the cement clinker is sintered, not in a rotary kiln, but in two different furnaces: a spouted bed kiln and a fluidized bed kiln. The heat generated in the process of cooling the cement clinker is recovered by a fluidized bed cooler and a packed bed cooler, which are more efficient than the conventional coolers. Compared with the rotary kiln system, the new technology significantly reduces NO{sub x} emissions, appreciably cuts energy consumption, and reduces CO{sub 2} emissions as well. Thus, the new system is an efficient cement sintering system that is friendly to the global environment. In this paper, we describe this new technology as one of the applied technologies at an industrial level that is being developed in the Clean Coal Technology Project, and we present the results from test operations at our pilot plant.
With the ever increasing awareness of the toxicity of Pb, significant pressure has been put on the electronics industry to get the Pb out of solder. This work pertains to the development and characterization of an alloy which is Pb-free, yet retains the proven positive qualities of current Sn-Pb solders while enhancing the shortcomings of Sn-Pb solder. The solder studied is the Sn-4.7Ag-1.7Cu wt% alloy. By utilizing a variety of experimental techniques the alloy was characterized. The alloy has a melting temperature of 217{degrees}C and exhibits eutectic melting behavior. The solder was examined by subjecting to different annealing schedules and examining the microstructural stability. The effect of cooling rate on the microstructure of the solder was also examined. Overall, this solder alloy shows great promise as a viable alternative to Pb-bearing solders and, as such, an application for a patent has been filed.
Manufacturers may be required to design transformers to overload specifications. Oil viscosity changes and loss variation with temperature are not accounted for in the industry loading guide. A comprehensive test program was performed using a winding assembly with imbedded thermocouples. Steady state and transient tests were performed for natural and non-directed forced oil circulation. The temperature distribution in the winding was not linear with height as usually assumed. A large number of temperature sensors is required to determine the hot spot location. The location of the hot spot was found to be different and less predictable for natural oil circulation compared with non-directed forced oil circulation especially during overload conditions. This paper reports that improved loading guide equations were developed to account for oil viscosity, resistance change, cooling duct oil rise, and location of the hot spot.
Support for raising energy efficiency is reported for the following five areas during 1998-2001: 1. Fuel-based energy systems with the sub-areas: Sustainable production of biofuels, including ash recycling; Cogeneration; and Large scale heat production. 2. Transport with two sub-areas: Internal combustion engines; and Electric drive-lines. 3. Power production/Power technology with the sub-areas: Hydropower; Wind power; Power transmission and distribution; and Photovoltaic solar cells. 4. Industry with the sub-areas: Processes; and Support systems in industry. 5. Buildings with the sub-areas: Heating, cooling and climatic shields; and Components and support systems. In total, 1,800 M SEK (about 180 M USD) was contributed by the Energy Administration during this period. An overview of the projects is presented in this report.
Energy is a critical factor which determines the progress of rural development. Energy is therefore an area of concern. The quality, availability and cost of conventional energies, plus the associated environmental effects are a growing problem - not only for the health infrastructure but also for agriculture and domestic life. This is true not only in developing countries where the fast growing industries and urban populations demand a soaring proportion of available energy at the expense of the rural communities, but also in the poorest countries with weak energy infrastructure. Renewable energies, much studied in the last 20 years, can meet the needs of rural health and education services and communities by providing high quality, low cost, non-polluting energy. Solar energy, in particular, has the flexibility to produce electricity, heat and cooling. Solar technologies, furthermore, are backed by an established and experienced ...
The objective of this 3.5 year project is to develop a commercially competitive vehicle powered by ethanol (or ethanol blend) that can meet California`s ultra-low emission vehicle (ULEV) standards and equivalent corporate average fuel economy (CAFE) energy efficiency for a light-duty passenger car application. The definition of commercially competitive is independent of fuel cost, but does include technical requirements for competitive power, performance, refueling times, vehicle range, driveability, fuel handling safety, and overall emissions performance. This report summarizes a system design study completed after six months of effort on this project. The design study resulted in recommendations for ethanol-fuel blends that shall be tested for engine low-temperature cold-start performance and other criteria. The study also describes three changes to the engine, and two other changes to the vehicle to improve low-temperature starting, efficiency, and emissions. ...
Nowadays, computational fluid dynamics is being applied in many fronts to improve the understanding of the flow and heat transfer behaviour in engineering applications. Unfortunately, there are not so many computational investigations regarding the ventilation and temperature distribution in discs-brakes. In this respect, this study presents a (CFD) analysis is carried out to investigate temperature distributions and flow patterns through disc brakes. The final goal is the development of shapes that optimize heat dissipation rates dictating the stopping capability of disc brakes. High performance discs brakes have a variety of cooling channels and the optimization of these passages is a challenging task for the manufacturing industry. High values of heat transfer coefficients of disc-brake configurations, are the most critical quantities during the design phase of new braking systems. In this context, a parametric study of the influence of the ...
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology' project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Test data are as follows: CORA-13 (FZK) for the Core Heat-up Module; VI-3 of HI/VI Test (ORNL) for the FP Release from Fuel Module; KROTOS-37 (JRC-ISPRA) for the Molten Core Relocation Module; Water Spread Test (UCSB) for the Debris Spreading Model and Benard's Melting Test for Natural Convection Model in the Debris Cooling Module; Hydrogen Burning Test (NUPEC) for the Ex-Vessel Thermal Hydraulics Module; PREMIX, PM10 (FZK) for the Steam Explosion Module; and SWISS-2 (SNL) for the Debris-Concrete Interaction Module. Second, with the Simulation Supervisory System, up to ...
The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat transfer whilst ...
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost ...
This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts ...
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts ...
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts ...
Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, and closure relations ...
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced ...
A new rapid solidification process machine will be able to produce eight-inch diameter by six-inch thick finished cavities at the rate of one per hour - a rate that will change the tooling industry dramatically. Global Metal Technologies, Inc. (GMTI) (Solon, OH) has signed an exclusive license with Idaho National Engineered and Environmental Laboratories (INEEL) (Idaho Falls, ID) for the development and commercialization of the rapid solidification process (RSP tooling). The first production machine is scheduled for delivery in July 2001. The RSP tooling process is a method of producing production level tooling in prototype timing. The process' inventor, Kevin McHugh, describes it as a rapid solidification method, which differentiates it from the standard spray forming methods. RSP itself is relatively straightforward. Molten metal is sprayed against the ceramic pattern, replicating the pattern's contours, surface texture and details. After ...
Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it will be examined all parameters and done comparison with already existing ones. It is analyzed ...
Macrofouling of cooling-water systems is one of the more significant and costly problems encountered in the nuclear power industry. Both marine and freshwater macroinvertebrates can be responsible for losses in plant availability because of plugged intakes and heat transfer equipment. There is a greater diversity of macrofouling organisms in marine waters than in fresh waters. Marine macrofouling organisms include barnacles, mollusks, bryozoans, and hydroids. Barnacles are crustaceans with feathery appendages, which allow them to attach to a variety of surfaces. They are a major cause of severe macrofouling because they can remain attached even after death. The major freshwater macrofouling organisms include the Asiatic Clam (Corbicula fluminea) and the newest freshwater macrofouler, the Zebra Mussel (Dreissena polymorpha). The introduction of the Zebra Mussel into the Great Lakes has created economic and ecological problems that will not ...
In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already supports the advance of SRF and closely ...
A 1,200 bird solar chicken brooder was indigenously designed and operated by the Indian scientists for the first time in the country as a Project under funding by the Ministry of Non Conventional Energy Sources to the All India Women`s Conference. This multi disciplinary project was taken up on the International Sun Day, May 3, 1993 and completed on May, 1994. Data has been collected for the first nine months of operation. Its successful operation has justified multi disciplinary approach. The solar chicken brooder incorporates modern poultry concepts of breeding under controlled temperatures. In view of the mixed climate of Delhi, provision was made for heating and cooling both to take care of the 24 hour cycle. Comfort conditions have been identified and maintained (as is done in the their genetic characteristics) at different temperatures for a period of 8--10 weeks to grow them to a uniform weight of 2.0 kg. Growing them under controlled temperature for the ...
The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of water flows and the environmental impact of cooling towers. Other factors are also ...
This paper describes the challenges involved in the construction of a mid-rise housing development in Boston, Massachusetts, during which the development team elected to upgrade the initial design criteria from Minimum Building Code to Energy Star and Leadership in Energy and Environmental Design (LEED) certification. The various constraints imposed on the development were discussed, including constraints imposed by the involvement of substantial public funds as well as the constraints imposed by various funding sources that were approached to leverage energy efficiency and green building investment via competitive grant solicitations. Building owner and utility cost management priorities were outlined along with details of central mechanical system selection. Issues concerning isolation and compartmentalization were examined along with indoor pollution source control. A building load analysis was presented as well as details of daily heating and cooling ...
There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it essential to use alternatives ...
The Cryocycling of Energetic Materials Project is sponsored by the Memorandum of Understanding (MOU) on advanced munition technologies. This MOU is an agreement between the Department of Energy and the Department of Defense (Office of Munitions) that facilitates the development of technologies of mutual interest to the two Departments. The cryocycling project is one of several that focus on demilitarization aspects of conventional weapons and weapon systems. During FY94 the project pursued the development of analytical and numerical models that can be used to describe and optimize the cryocycling process for preparing energetic materials for recycle and reuse. In addition, the demilitarization stockpile of the Department of Defense was analyzed to identify candidate munitions for the process, and pilot scale cryocycling operations were begun at an industrial contractor. When a material is cryocycled, it is repeatedly subjected to cycles of rapid ...
Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)
At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to examine the designs in detail to determine whether the 95 F (35 C) limit was adequate to ensure occupant ...
The objectives of this program are to evaluate the Coal Fired Combined Cycle (CFCC) power plant conceptual design and to conduct supporting development programs for pressurized fluidized bed technology advancement in combustion/steam generator, gas turbine and hot gas cleanup technologies. The Coal-Fired Combined Cycle is the unique power plant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined-cycle power plant. The advantages of the combined cycle for higher efficiency and the potential of the pressurized fluidized bed combustor improvements in emissions could offer a new and attractive option to the electric utility industry. The CFCC approach provides for cooling the fluid bed combustor through the use of steam tubes in the bed which supply a steam turbine generator. The partially cooled combustion gases drive a gas turbine ...
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high ...
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption ...
Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the ...
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department ...
In 1994, the United States Department of Energy, the United States electric utilities and the geothermal heat pump (GeoExchange) industry formed a non-profit collaborative effort called the Geothermal Heat Pump Consortium (GHPC). The objectives were the reduction and/or elimination of 1.5 million metric tons of carbon equivalent per year and making geothermal heat pumps a significant part of the Heating Ventilation Air Cooling (HVAC) industry. Federal funding of 35 million dollars over six years was matched by 65 million dollars of private sector funds to attain these objectives and create a self-sustainable GeoExchange market. The major accomplishments of this endeavour, as well as the lessons learned were presented in this paper. The infrastructure was strengthened, first cost was reduced, and awareness of the technology was increased over the past six years as a result of the efforts deployed by the GHPC. More than ...
In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell system integrated. Specific computational models are developed for radiators and condensers to evaluate the ...
Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).
A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, ...
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had ...
In order to achieve the safe core cooling during normal operation and upset conditions, HANARO adopted an upward forced convection cooling system with dual containment arrangements instead of the forced downward flow system popularly used in the majority of forced convection cooling research reactors. This kind of upward flow system was selected by comparing the relative merits of upward and downward flow systems from various points of view such as safety, performance, maintenance. However, several operational matters which were not regarded as serious at design come out during operation. In this paper are presented the design and operational experiences on the unique cooling features of HANARO. (author)
Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.
Competitiveness of the UK furniture manufacturing industry.2010 ...is clear from the study that the UK furniture manufacturing industry has responded to the challenge of ...Competitiveness of the UK furniture manufacturing industry.2010
A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes ...
This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.
The laser cooling and trapping of ultracold neutral dysprosium has been recently demonstrated using the broad, open 421-nm cycling transition. Narrow-line magneto-optical trapping of Dy on longer wavelength transitions would enable the preparation of ultracold Dy samples suitable for loading optical dipole traps and subsequent evaporative cooling. We have identified the closed 741-nm cycling transition as a candidate for the narrow-line cooling of Dy. We present experimental data on the isotope shifts, the hyperfine constants A and B, and the decay rate of the 741-nm transition. In addition, we report a measurement of the 421-nm transition's linewidth, which agrees with previous measurements. We summarize the laser cooling characteristics of these transitions as well as other narrow cycling transitions that may prove useful for cooling Dy.
A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.
There are two types in quench distortion of steel parts: thermal distortion and transformation distortion. Quench distortion is caused mainly by uneven cooling rate of steel parts from Austenitising temperature. The rapid cooled side is lengthened (convex deformation); the slow cooled side is shortened (concave deformation). So, to control the quench distortion, it is necessary to regulate the cooling rate of steel parts during quenching. TWO COMPONENTS produce the quench distortion of steel parts: the thermal stress and transformation stress. Generally, the effect of the thermal stress on the quench distortion is stronger than the transformation stress. The quench distortion is caused by uneven cooling rate of the steel parts, from Austenitising temperature to Ms point and Ms-Mf range. So, to control the quench distortion, it is very important to regulate the ...
In an effort to minimize the distortion of bearing steel rings during the production process, 100Cr6 steel billets are spray formed with a unique cooling control system to control the cooling and solidification behavior of the deposits. Effects of heating around the deposits, gas cooling at the substrate bottom and the gas flow over the deposits are investigated both by numerical simulation and experiment. Porosity profiles and microstructures of spray formed bearing steel are examined and evaluated. The investigation results show that the thermal boundary conditions of the deposits play important roles on the cooling and solidification behavior of the deposits, especially at the deposit periphery. Porosity in the 100Cr6 bearing steel deposit can be reduced significantly with the special cooling control system.
A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.
We present a single solid-state laser system to cool, coherently manipulate and detect $^{25}$Mg$^+$ ions. Coherent manipulation is accomplished by coupling two hyperfine ground state levels using a pair of far-detuned Raman laser beams. Resonant light for Doppler cooling and detection is derived from the same laser source by means of an electro-optic modulator, generating a sideband which is resonant with the atomic transition. We demonstrate ground-state cooling of one of the vibrational modes of the ion in the trap using resolved-sideband cooling. The cooling performance is studied and discussed by observing the temporal evolution of Raman-stimulated sideband transitions. The setup is a major simplification over existing state-of-the-art systems, typically involving up to three separate laser sources.
This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)
Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power ...
BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
Three Legionella-like organisms were isolated from water from the cooling towers of two Australian institutions. The strains grew on buffered charcoal-yeast extract (BCYE) agar but not on BCYE agar...Full Text Available
The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.
This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available
disciplinary methods were used to independently determine the aerodynamic loads, the thermal response, and strardural performance of the hydrogen cooled ...
... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...
A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.
In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear power plants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.
Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.
An AHR (Advanced HANARO Reactor) based on the HANARO has been conceptually developed for the future needs of research reactors. Generally, a natural convection cooling in nuclear installations is an ultimate heat removal mechanism as an inherent safety feature. This paper presents the preliminary thermal hydraulic characteristics and safety margins for a natural convection cooling in the AHR.
Effect of cooling rates within the wide range (0.003-45 grad/s) on the complex of mechanical properties of (#alpha#-#beta#)-titanium alloy VT3-1 is studied in the process of heat treatment. Cooling conditions of semifinished product made of this alloy with a different structure providing optimum combination of strength, ductility fracture toughness, heat resistance, and endurance are determined.
The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.
Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable ...
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
Results are reported from dye tests of the dispersion of the vapor plume from the natural draft cooling tower of a fossil-fuel power plant located in the coastal region of Maryland.
Full text of publication follows: Slightly over-stoichiometric lithium orthosilicate pebbles have been selected as one optional breeder material for the European Helium Cooled Pebble Bed (HCPB) blanket. This material has been developed in collaboration of Research Center Karlsruhe and the Schott Glass, Mainz. The lithium orthosilicate pebbles are fabricated from lithium hydroxide and silica by a melting and spraying method in a semi-industrial scale facility. Lithium hydroxide was selected as the precursor since enriched lithium hydroxide is commercially available. The lithium orthosilicate pebbles produced by the process contains oxide phases besides orthosilicate, but it was also found that the oxide phases can be decomposed by annealing at high temperatures. The lithium orthosilicate pebbles produced in this way possesses satisfactory pebble characteristics. Therefore, the authors performed out-of-pile annealing tests using the lithium ...
Thermoplastic encapsulation has been extensively studied at Brookhaven National Laboratory`s (BNL) Environmental and Waste Technology Center (EWTC) as a waste encapsulation technology applicable to a wide range of waste types including radioactive, hazardous and mixed wastes. Encapsulation involves processing thermoplastic and waste materials into a waste form product by heating and mixing both materials into a homogeneous molten mixture. Cooling of the melt results in a solid monolithic waste form in which contaminants have been completely surrounded by a polymer matrix. Heating and mixing requirements for successful waste encapsulation can be met using proven technologies available in various types of commercial equipment. Processing techniques for thermoplastic materials, such as low density polyethylene (LDPE), are well established within the plastics industry. The majority of commercial polymer processing is accomplished using extruders, ...
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation have been reported. ...
About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten chemischen Produktionsanlage an einer mit Flusswasser beaufschlagten Kuehlwasserleitung ...
This article gives an account of the recent development of light water reactors new concepts in the world. Different projects are being studied. The CE80+ from Combustion Engineering (CE) is a 1350 MWe-PWR-type reactor whose primary circuit is confined in a spherical metallic containment. This reactor was certified by NRC (national regulatory commission) in mid-1996. The APWR (advanced pressurized water reactor) is developed by MHI (Mitsubishi heavy industries) in a collaboration with Westinghouse, this PWR-type reactor fitted with 4 loops derived from the SP90 model that was developed by Westinghouse during the eighties. 2 units of ABWR (advanced boiling water reactor) were commissioned in Japan in 1996 and 1997, ABWR was certified by NRC in mid-1996. The BWR90+ is developed by ABB-atom (Sweden) and it represents a cautious advanced version of the BWR75. Passive reactors are reactors that rely only on potential energy (compressed gas, gravitational flow or ...
This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that ...
In order to provide pigs a comfortable sleeping area in hot weather, a floor cooling system was designed and applied to production buildings. Experiments were conducted to compare the floor temperatures and to observe the lying behaviour of pigs in the sleeping area of the buildings with and without floor cooling system. The results showed that, without the floor cooling system, the floor temperature was nearly the same as the air temperature in the open pig house. With the floor cooling system, the floor temperature of the sleeping area was controlled at 22-26degreeC, even though the air temperature was as high as 34degreeC, which improved the comfort of the pigs in the sleeping area. The pig lying behaviour was greatly affected by the floor temperature. More than 85% of the pigs were lyi...
The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships for friction factor ...
Different cooling speeds after previous solution annealing at 1130deg C for 0.5 hour were simulated in laboratory experiments. The following conditions were examined: (1) Direct water quenching, (2) cooling in air for 0.5 min to 950deg C/water quenching, (3) cooling in air for 1.5 min to 750deg C/water quenching, (4) cooling in furnace for 5 min to 750deg C/water quenching. The results of the investigations have shown that a variation of the cooling conditions causes considerable changes in the creep behaviour. (orig.).
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
Both simulations and recent experiments conducted at the Advanced Photon Source showed that the performance of liquid-nitrogen-cooled single-silicon crystal monochromators can degrade in a very rapid nonlinear fashion as the power and for power density is increased. As a further step towards improving the performance of silicon optics, we propose cooling with liquid helium, which dramatically improves the thermal properties of silicon beyond that of liquid nitrogen and brings the performance of single silicon-crystal-based synchrotrons radiation optics up to the ultimate limit. The benefits of liquid helium cooling as well as some of the associated technical challenges will be discussed, and results of thermal and structural finite elements simulations comparing the performance of silicon monochromators cooled with liquid nitrogen and helium will be given.
A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)
The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an ...
After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.
The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. ...
A comparative core design study is performed on Pb-Bi cooled reactors with forced and natural convection (FC and NC) cooling. Major interests of the study are core performance and core safety features. The designed core concepts with nitride fuel achieve reasonable breeding capability. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features to withstand unprotected events due to negative reactivity feedback by Doppler effect, control rod drive line expansion, etc. These results lead to a conclusion that both of concepts have possible capability as one of future promising core concepts. A FC cooling core concept has more advantage if fuel recycle viewpoint is emphasized. (author)
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread ...
Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. ...
Discussion is presented of world crude steel production, the Japanese steel industry and its expectations of the Canadian coal industry. It is concluded that the Canadian coal industry should pay attention to the trend in customer's requirements regarding coal quality, maintain price competitiveness in the international market place, and remain flexible with regard to the market trend.
The Danish windmill industry has become an international success. This book describes the historical development of the Danish windmill industry and technology and evaluates the innovation ability of these. (LG) 176 ref.
This cost-effectiveness analysis supports the proposed effluent limitations guidelines and standards for the Metal Products and Machinery Industry (MP and M) Phase I Industry. The report assesses the cost-effectiveness of five regulatory options for indir...
This report discusses the current state and the future of the Dutch basic metal industry. The steel industry and the aluminium industry are discussed in detail. First their current energy use, the technology and their product markets are analysed. The competitiveness of Dutch and Western European producers is discussed. Main technological developments and other key issues (especially future CO2 policies) are analysed. Based on this analysis, scenarios are developed for the energy use in the basic metal industry for the period 2000-2020. 88 tabs., 55 figs., 143 refs.
The US Department of Energy (DOE) Office of Industrial Technologies (OIT) conducts research and development activities which focus on improving energy efficiency and providing for fuel flexibility within US industry in the area of industrial conservation. The mission of OIT is to increase the utilization of existing energy-efficient equipment and to find and promote new, cost-effective ways for industrial facilities to improve their energy efficiency and minimize waste products. To ensure advancement of the technological leadership of the United States and to improve the competitiveness of American industrial products in world markets, OIT works closely with industrial partners, the staffs of the national laboratories, and universities to identify research and development needs and to solve technological challenges. This report contains summaries of the ...
Jun 16, 2011 ... Description: Most of the approximately 25 to 30 million tons of industrial wood waste generated in the United States per year is burned for ...
This report discusses the development and demonstration of innovative combustion technologies that improve energy conservation and environmental practices in the US industrial sector. The report includes recommendations by industry on R&D needed to resolve current combustion-related problems. Both fundamental and applied R&D needs are presented. The report assesses combustion needs and suggests research ideas for seven major industries, which consume about 78% of all energy used by industry. Included are the glass, pulp and paper, refinery, steel, metal casting, chemicals, and aluminum industries. Information has been collected from manufacturers, industrial operators, trade organizations, and various funding organizations and has been supplemented with expertise at the Idaho National Engineering Laboratory to develop a list of suggested research and ...
Sources of industrial emissions of 1,3-butadiene are discussed both by process (production, consumers) and type (equipment leaks, point sources). Quantification of the emissions are presented, as reported...Full Text Available
Efficiency and Renewable Energy EERE Home | Programs & Offices | Consumer Information Chemicals Search Search Help Chemicals EERE » Industrial Technologies Program » Chemicals...
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing ...
This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. ...
The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the ...
The SONACO experiments are conducted on an electrically heated 37-pin rod bundle, immersed in liquid sodium and contained within a hexagonal wrapper. The rig was designed to investigate natural convection cooling for a geometry representative of fast reactor fuel assemblies. Heat can be removed from the test section in several ways, but in this paper only the axial cooling mode is examined. Above the heated bundle is a plenum, at the top of which is a cooling coil containing a separate, forced sodium flow. Heat transfer from the bundle to this cooling coil is effected by means of buoyancy driven circulatory flow in the sodium, and in the axial cooling mode almost all the heat is removed by the coil. This mode is intended to simulate the natural convection cooling of a blocked fuel assembly by way of thermosyphon coupling to the inner pool. In this paper ...
We show the propagation of regularity, uniformly in time, for the scaled solutions of the inelastic Maxwell model for small inelasticity. This result together with the weak convergence towards the homogenous cooling state present in the literature implies the strong convergence in Sobolev norms and in the $L^1$ norm towards it depending on the regularity of the initial data. The strategy of the proof is based on a precise control of the growth of the Fisher information for the inelastic Boltzmann equation. Moreover, as an application we obtain a bound in the $L^1$ distance between the homogeneous cooling state and the corresponding Maxwellian distribution vanishing as the inelasticity goes to zero.
For light water reactors, loss of coolant is an important point in safety analysis, whereas for gas-cooled reactors the ingress of water into the core region is an incident of safety relevance. The applicability of the computer code system GAMTEREX to pebble beds of spherical high-temperature gas-cooled reactor fuel elements with simulated water ingress is verified by experiment. The measurements were performed at a Siemens-Argonaut reactor, using its ring core as a driver zone for a pebble-bed core in the center of the reactor.
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).
The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.
The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.
Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).
Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).
The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)
This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.
A 20-cell PEFC stack was designed and built. Resin impregnated graphite was used as bipolar plate material. The air cooling of the stack was optimized by introducing high surface structures into the open space of the cooling plates. At {eta} (H{sub 2} LHV) = 0.5 a power of 880 W was obtained under conditions of low gas-pressures of 1.15 bar{sub a}. The auxiliary power for process air supply and cooling at 880 W power is less than 7% of the power output, indicating that the described system may be operated at a high efficiency. (author) 5 figs., 2 refs.
This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.
Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired power plant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.
Various schemes of cooling have been investigated for the purpose of assessing potential benefits on the operational characteristics of the Syrian MNSR reactor. A detailed thermal hydraulic model for the analysis of MNSR has been developed. The analysis shows that an auxiliary cooling system, installed in the pool which surrounds the lower section of the reactor vessel, will significantly offset the consumption of excess reactivity due to the negative reactivity temperature coefficient, Hence, the maximum operating time of the reactor is extended. Compared with experimental data, the suggested model proves to be valid for the analysis of MNSR behavior under both steady state and transient conditions. (author)
Nickel-based alloys are presently used as brazing filler metals for components which undergo mechanical stress in corrosive conditions, f. e. heat exchangers. When soldering chrome containing steel parts with nickel based brazing filler metals additionally containing boron and silicon a reaction of chrome and boron can occur. This evolution of chromium borides, depositing on grain boundaries, causes a lack of chrome in the steel part. A drop of the chrome content in the parts below 13 % leads to a loss of corrosion resistance. It is possible to change the microstructure of brazing joints by modification with chromium and molybdenum. Continuous brittle phases could be successfully avoided with this modification. Furthermore it could be shown that the choice of additives, the heating respectively cooling rate and the brazing temperature have important influence on the microstructure evolution and therefore on the mechanical and corrosive properties of joints. ...
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling optional boundary ...
The objective of this study was to analyze the industrial demand for energy in seven Organization for Economic Cooperation and Development (OECD) countries with particular emphasis on fuel substitution between oil, natural gas, coal, and electricity. Changing fuel demand also results from economic growth, changes in industrial structure, and changes in the energy intensity of industrial output. A historical analysis of these factors and fuel substitution is undertaken for industry as an aggregate, and for 12 specific industries. The major results of the historical analysis are: (1) fuel use changes are a result of fuel switching, changing energy intensity, changing industrial structure, and economic growth; (2) fuel substitutability depends upon fuel use. The three fossil fuels are substitutes in the industrial heat market, but there are ...
to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.
The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...
The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature batteries.
Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...
lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...
Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)
Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).
... CVn) consisting of a dM3 star and a cool white dwarf that must have evolved through the common-envelope stage of binary star evolution (Else van ...
Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.
to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
The thermal transpiration method has been employed to replace the temperature of liquid nitrogen by #approx#12 K. This is done by bubbling He (g) through the liquid nitrogen.
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
The production, principal applications, characteristics and properties, advantages of the gas natural is showed. A sectorial overview of the ceramic industry and the utilization of the natural gas in the ceramic industry is presented. The expectations are systematized and the impact of the natural gas utilization in the ceramic industry is evaluated. Some conclusions are withdrawn and recommendations suggested.
In this study, we investigate an inter-industrial and inter-regional recycling system for industrial waste by the cement industry in Japan. We develop a linear programming model that represents cement production processes and waste transportation of all cement factories in Japan. We simulate cost and CO{sub 2}-minimizing systems. The result implies that making waste transportation more efficient in cost is an effective means for CO{sub 2} reduction. (author)
Advances in robotic technologies reflected in commercially available and demonstrated capabilities provide exceptional alternatives to the designer of new and upgraded production processes. This paper discusses the states of the art of these technologies, describes some of the research and application engineering which has extended and exploited these capabilities, and provides some conceptual synthesis of advanced robotics and other industrial automation to hypothetical nuclear industry/laboratory tasks. Nuclear industry applications are oriented upon tasks in hazardous and contaminating environments and with hazardous materials.
Table of Contents: Executive Summary; Introduction; Data Sources; Industry Profile and Economic Baseline; Industry Compliance Costs; Industry Impacts; Additional Economic Impacts; Cost-Effectiveness; Environmental Impacts and Benefits; Social Costs and Be...
The Netherlands Chemical Industry Association (VNCI) is investigating the potential for expansion of the CHP capacity in the Dutch chemical industry. This report discusses the return on investment for CHP installations and the market conditions. Moreover, scenario results are presented for the CHP potential and the development of CHP in the chemical industry until 2020. [Dutch] De Vereniging van de Nederlandse Chemische Industrie (VNCI) heeft onderzoek laten uitvoeren om vast te stellen welke economische en beleidsmatige voorwaarden er zijn om het WKK-potentieel in de Nederlandse chemie te realiseren. Dit rapport brengt de marktpositie van WKK en de rentabiliteit van investeringen in WKK in beeld. Verder worden resultaten gegeven voor de potentiele energiebesparing en emissiereductie en wordt een scenario gepresenteerd voor het WKK-potentieel in de chemische industrie tot 2020.
This paper describes industrial aspects of combined inventory management and routing in maritime and road-based transportation, and gives a classification and comprehensive literature review of the current state of the research. The literature is contrasted with aspects of industrial applications from a constructive, but critical, viewpoint. Based on the status and trends within the field, future research is suggested with regard to both further development of the research area and industrial needs. By highlighting the industrial aspects, practitioners will hopefully see the benefit of using advanced decision support systems in complex situations related to combined inventory management and routing in their business. In addition, a classification and presentation of the research should hel...
The production of process heat for agriculture and industry is one of the applications of solar energy which is very close to economic competitivity. Solar collectors can be produced at a reasonable cost by existing industries and are used optimally through applications which present a good time correlation between energy needs and the possible production of solar heat. This article studies heat consumption in industrial and agricultural sectors, gives hints on collectors choices, rates the different projects by simulation taking into account the nature of agricultural and industrial activities and the geographical location of the projects, examines when the equipment first competes according to hypotheses made on the various energy and collectors cost.
A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally
A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
We used the tissue distribution of ({sup 14}C)butanol to quantitate regional blood flow in the spinal cord (RSCBF) of pentobarbital-anesthetized, normothermic rats in which segmental local cooling pentobarbital-anesthetized, normothermic rats in which segmental local cooling of the spinal cord (to 25-28{degrees}C) at vertebral levels C4-C6 (n = 6) or T13-L1 (n = 6) was induced. Thirty minutes later, blood flow measurements were made at seven levels of the spinal cord and in the sciatic nerve trunks and biceps femoris muscles. Sham-cooled rats served as controls (n = 12). In control rats, RSCBF varied between 41.5 +/- 2.4 and 65.1 +/- 3.2 ml.min-1.100 g-1. Local cooling of the C4-C6 cord segment reduced RSCBF by 32%, from 65.1 +/- 3.2 to 44.4 +/- 3.5 ml.min-1.100 g-1 (P less than 0.01). Tissue vascular resistance (R) in the cooled C4-C6 segment was elevated versus control. There were ...
The aim of this study concerns the use of numerical methods for the resolution of the Reynolds Averaged Navier Stokes equations adapted to the simulation of the cooling of the trailing edge of a stator in a high pressure turbine. These methods, based on the elsA solver developed at ONERA, use a four steps Runge Kutta time discretization scheme and a Jameson centered space discretization scheme. The scheme is applied through a finite volume approach on control volume centered on the cells of a multi-block structured mesh. Turbulence is simulated either through the algebraic Michel model, or through the one-transport-equation Spalart-Allmaras model, or through the two-transport-equations k 1, k {omega} and k {epsilon} models, and through ASM model. A simulation of the flow in a bidimensional stator, without cooling, is carried out. The cooling, which is realized with trailing edge slots, is then simulated on a bidimensional ...
Natural cooling conditions of the nuclear fuel in the channel type reactor after its shut down are commonly determined with relatively high uncertainty. This is not only to he lack of adequate measurements of thermal parameters i.e. the residual power generation, the coolant flow and temperatures, but also due to indeterminate model of convection mechanism. The numerical simulation of natural convection in multitube fuel assembly in the fuel channel leads to various convection modes including evidently chaotic behaviour. To determine the real cooling conditions in the MARIA research reactor a series of experiments has been performed with fuel assembly equipped with a set of thermocouples. After some forced cooling period (the shortest was half an hour after the reactor shut down) the reactor was left with the only natural convection. Two completely different cooling modes have been observed. The MARIA ...
This paper is concerned with the development and application of an analytical method for the performance prediction of air cooled condensers. A local analysis is employed in which the condenser is considered as a matrix of small basic heat transfer modules. For each element, local film coefficients for both the air and the condensing fluid are determined according to the existing local conditions, including the two-phase flow regime. The paper considers an application of the method to heat pump condensing.
The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.
The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)
This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the ...
The two favourable dry storage concepts being under consideration in the Federal Republic of Germany are presented and the physical behaviour or natural convection cooling with air is explained. With the three examples cask store, vault storage horizontally and vertically arranged the main thermodynamical design parameters and their influence on the efficiency of the cooling system and on the temperature distribution inside the store and of the stored material are discussed. Moreover, the importance of the fulfilment and the harmony of all safety criteria and the difficulties while to do so are carried out especially with the vault store.
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as ...
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
This report contains data collected on a monthly basis over the period April, 1973 - April, 1975 for dustfall particulates, sodium and chloride and SO2 levels obtained from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO and ...
This report contains a summary of monthly dustfall, SO2, rainfall, crops and soils information obtained over the period May, 1976 to March, 1977 from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO which is located 65 km sout...
A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle ...
Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in ...
Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...
Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...
Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and ...
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load ...
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by ...
A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and hydrogen's ...
This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the gravity ...
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is ...
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a ...
In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...
Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.
Over the last decade {\\it ab initio} modeling of material properties has become widespread in diverse fields of research. It has proved to be a powerful tool for predicting various properties of matter under extreme conditions. We apply modern computational chemistry and materials science methods, including density functional theory (DFT), to solve lingering problems in the modeling of the dense atmospheres of cool white dwarfs ($T_{\\rm eff}\\rm <7000 \\, K$). Our work on the revision and improvements of the absorption mechanisms in the hydrogen and helium dominated atmospheres resulted in a new set of atmosphere models. By inclusion of the Ly-$\\rm \\alpha$ red wing opacity we successfully fitted the entire spectral energy distributions of known cool DA stars. In the subsequent work we fitted the majority of the coolest stars with hydrogen-rich models. This finding challenges our understanding of the spectral evolution of ...
Grain refinement behavior of copper alloys cast in permanent molds was investigated. This is one of the least studied subjects in copper alloy castings. Grain refinement is not widely practiced for leaded copper alloys cast in sand molds. Aluminum bronzes and high strength yellow brasses, cast in sand and permanent molds, were usually fine grained due to the presence of more than 2% iron. Grain refinement of the most common permanent mold casting alloys, leaded yellow brass and its lead-free replacement EnviroBrass III, is not universally accepted due to the perceived problem of hard spots in finished castings and for the same reason these alloys contain very low amounts of iron. The yellow brasses and Cu-Si alloys are gaining popularity in North America due to their low lead content and amenability for permanent mold casting. These alloys are prone to hot tearing in permanent mold casting. Grain refinement is one of the solutions for reducing this problem. However, to use this ...
Industrial effects have long been significant factors in wage inequality. Previous research indicates that wage differentials across industries were increasing through the mid 1980s. Using more recent data, however, we find that the level of inter-industry wage dispersion declined by 36% from 1986 to 2002 despite the continued trend towards increasing inequality in the labor force. This decline in inter-industry wage dispersion is evident across gender and educational groups. Using multilevel growth curve models, our multivariate results indicate that the decline is only weakly related to industrial changes in education, occupation or even productivity despite the fact that the latter variable had been a critical factor in the prior period. Indicators of globalization and downsizing also d...
A design for passive cooling of large containment structures has progressed sufficiently to move forward into the detailed design stage necessary for plant construction. For such application, a safety analysis report has already been submitted to the US Nuclear Regulatory Commission. The design considers an annulus between the inner steel containment vessel and outer, thick-walled concrete shield building with chimney-like natural convection cooling driven only by a density gradient relative to the atmosphere. Air within the annulus is heated as internal containment temperature rises and heat is transferred through the steel containment shell. The resulting air density gradient between the annulus and the environment causes the heated air to rise, producing a natural convection flow through inlets in the shield building, past the steel shell, and out an exit chimney. Several options for enhancing passive heat removal of large containment ...
Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through ...
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB ...
A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a ...
A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...
We have investigated the microstructure evolutions in the Ti17 near #beta# titanium alloy during heat treatments. The phase transformation has first been studied experimentally by combining X-ray diffraction analysis, electrical resistivity and microscopy observations. From a series of isothermal treatments, a IT diagram has been determined, which takes into account the different morphologies. Then, a Johnson-Mehl-Avrami-Kolmogorov (JMAK) model has been successfully used to describe the phase transformation kinetics during either isothermal or cooling treatments. Finally, the coupling of the JMAK model to the finite element software ZeBuLoN allowed us to investigate the evolution of the spatial distribution of the different morphologies during the cooling of an aircraft engine shaft disk after forging.
One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for ...
An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ratio provides a ...
Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.
The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...
After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)
The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.
The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.
A novel continuous laminar shear structuring crystallizer with a suitable cooling system was designed and built. This is a new method to continuously crystallize edible fat in the desirable polymorphic form from the melt while being uniformly sheared.The machine consists of four main sections: Feed unit, shearing mechanism, cooling system and power unit. In each of these sections specific design considerations are taken into account which makes the process controllable and continuous. The shearing unit is made of two concentric cylinders. The internal cylinder is stationary and has a cooling system inside for temperature control. The outer cylinder rotates to produce a uniform shear in the sample fluid placed in the 1.5mm gap between the cylinders. The sample's feed rate is controlled whil...
Background: Ecchymosis, oedema, haematoma and pain after SMAS-based facelift surgery are all the direct result of the physical trauma of surgery and subsequent inflammatory response. Hilotherapy is a novel form of cryotherapy that purports to minimise these events through single-use face masks circulating cooled, sterile water. This study was performed to assess the validity of Hilotherapy in this population of patients. Methods: Over 14 weeks fifty consecutive patients were randomised to post-operative facial cooling with Hilotherapy or management with standard dressings alone, while fifteen subsequent, consecutive patients were randomised to cooling of one side of the face but not the other. Assessment of ecchymosis, oedema, haematoma and pain was performed independently by clinical staf...
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, ...
This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine system will also be needed.
A model is presented for heat and fluid flow during hammer and anvil splat cooling. Predictions are made for the effects of superheat and hammer speed on splat thickness, cooling rate, and subsequent glass formation. The regime of Newtonian heat flow is extended well beyond the previously accepted limiting value of Nusselt number. Measurements of the structure, stability, and thickness of Fe{sub 80}B{sub 20} and Pd{sub 80}Si{sub 20} hammer and anvil splats qualitatively confirm the model prediction. Variations of superheat in shock tube splats produced similar trends to those observed in the hammer and anvil device. In an attempt to vary the equivalent of hammer speed in a shock tube device, an orifice producing a supersonic shock wave was utilized. Significant splat flake thickness reductions resulted as compared to subsonic orifices.
A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
In a turbine rotor, a thermal mismatch between various component parts of the rotor occurs particularly during transient operations such as shutdown and startup. A thermal medium flows past and heats or cools one part of the turbine which may have a deleterious thermal mismatch with another part. By passively controlling the flow of cooling medium past the one part in response to relative movement of thermally responsive parts of the turbine, the flow of thermal medium along the flow path can be regulated to increase or reduce the flow, thereby to regulate the temperature of the one part to maintain the thermal mismatch within predetermined limits.
The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)
Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
The central engine of Gamma Ray Bursts is hidden from direct probing with photons mainly due to the high densities involved. Inferences on their properties are thus made from their cosmological setting, energetics, low-energy counterparts and variability. If GRBs are powered by hypercritical accretion onto compact objects, on small spatial scales the flow will exhibit fluctuations, which could in principle be reflected in the power output of the central engine and ultimately in the high energy prompt emission. Here we address this issue by characterizing the variability in neutrino cooled accretion flows through local shearing box simulations with magnetic fields, and then convolving them on a global scale with large scale dynamical simulations of accretion disks. The resulting signature is characteristic, and sensitive to the details of the cooling mechanism, providing in principle a discriminant for GRB central engine properties.
At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The ...
An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...
The cattle industry in Canada has changed greatly over the past several decades. Size of the national dairy herd has reduced steadily but this reduction has been more than offset by an increase in...Full Text Available
An overview of the Department of Energy`s Office of Industrial Technologies and its private sector partnerships is presented. Commercial success stories and real-world benefits of the technology partnerships are discussed.
The report contains detailed information with regard to the data collected in the 1977 Survey of Industry on the Use of Food Additives undertaken by committees of the Food and Nutrition Board of the National Research Council under sponsorship of the Food ...
Most Danish windmill manufacturers have experienced a grave economic crisis during the last three years. In 1987, the total windmill industry in this country ran at a loss of 40 million Danish crowns where the turnover was 550 million crowns. Danish firms...
...Agriculture Analysis of food supply chains and linkages in relation to quality and safety assurances Dept of Primary Industries, Australia Impact of food chain quality assurance requirements on farmer adoption and competitiveness UK Research Councils Review of environmental certification through farm assurance followed by industry developmental workshop Agriculture & ...
The aim of this work is to the application of a methodology to evaluate the energy associated to the industrial solid wastes in the metropolitan region of Campinas. The methodological route proposed is: the characterization of the research area and the production/management of the industrial solid wastes; the energetic classification and the qualitative/quantitative research of the energy associated to the industrial solid wastes; and, the valuation of the applicability of the energetic utilization mechanisms proposed to the region. This methodology when applied at the Campinas metropolitan region proved to be valid and it resulted in a synthetically presentation of the social and environmental reality of the industrial sector and the destination of the wastes, as well as it indicated the potentialities related to the energetic utilization of the industrial solid waste in the ...
An incidence study of malignant melanoma of the skin (MMS), conducted previously among the workers of four plants of a large telecommunications industry located in Montreal, Canada, showed a standardised...Full Text Available
Taiwan has completed a very successful five-year industrial waste minimization (IWM) demonstration and promotion project sponsored by the government. From 1990 to 1995, the project successfully disseminated the IWM concept of pollution prevention (P2) to industries. It effectively reduced industrial waste while significantly benefitting the economy by assisting industries in implementing in-plant IWM programs. In July 1995, the second stage of the five-year IWM and ISO 14000 promotion project was initiated for further promoting the IWM, P2, and cleaner production and, in particular, coping with the upcoming international environmental management standards (ISO 14000). To assist industries in establishing an environmental management system (EMS) and accumulating related experience, an EMS pilot demonstration project of five model industries and an ISO 14001 EMS ...
This report estimates the economic and financial effects of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts...
The report presents detailed technical information concerning application of flue gas desulfurization (FGD) systems to industrial boilers. The information was obtained by a survey of plant personnel, control system vendors, regulatory agencies, and consulting engineering firms. T...
This analysis, submitted in support of proposed effluent limitations guidelines and standards for the centralized waste treatment (CWT) industry, investigates the cost-effectiveness of 24 regulatory options, representing all possible combinations of nine ...
Toluene diisocyanate (TDI) and methylene diphenyldiisocyanate (MDI) are used in large quantities in the polyurethane foam manufacturing industry. Both substances are mutagenic and at least TDI is carcinogenic...Full Text Available
Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).
Risoe`s 40th anniversary was celebrated June 3, 1998 by a symposium held at Risoe. The interaction of research at Risoe with academia and industry was presented in both national and international perspective. Most of the presentations are in English, a few in Danish. (au)
An overview of the Canadian mining industry`s state of preparedness for the Year 2000 is presented. Committees within the mining industry are working on scheduling and implementing activities, defining criticality, monitoring remedial action, and contingency planning. The Mining Association of Canada is working with the Federal Government`s National Contingency Planning Group to deal with potential threats to health and security. Survey results suggest that mining poses a low to medium risk based on the state of planning for Y2K. The results of a survey of member preparedness is tabulated. 1 tab.
The power industry is undergoing major changes. Deregulation and a competitive climate demand effective solutions. Costs and losses must be reduced, and overall efficiency must be raised. Industrial options connected to energy market and environmental considerations are discussed. Themes discussed in this paper are environmental challenges, the fuel factor, power plants in use today, the Norwegian power system, the European system, power exchange across borders, the transmission system, the future European system, and options for Norwegian industry. 27 figs.
For reliable operation and the optimization of production, industrial fermentation processes require appropriate tools for monitoring the process in real time. This work presents the structure and operation of a soft sensor for the on-line monitoring of biomass and product concentration during salinomycin and bacitracin fermentation in an industrial, 80-m^3 batch reactor; moreover it provides a tool for evaluation of batch production verified in industrial application. The process estimation algorithm consists of decoupled growth and product models, which ensures an unbiased convergence of the estimator and the robustness of the model. The production of secondary metabolites is described with a non-structured model upgraded with a variable forgetting factor that demonstrated a successful e...
...Surface Aerators Products and Equipment Find and compare a variety of surface aerators products and equipment on the world's largest environmental industry portal. ...
...Extraction Arms Products and Equipment Find and compare a variety of extraction arms products and equipment on the world's largest environmental industry portal. ...
... Tunnel Composting Products and Equipment Find and compare a variety of tunnel composting products and equipment on the world's largest environmental industry portal. ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
Energy productivity and energy intensity within the industrial sector of the economy are examined. Results suggest that relative prices and other economic factors can explain much of the variation in both energy productivity and energy intensity for manufacturing and mining and for the industrial sector as a whole. Cyclical factors, seasonal factors and trend variables are also useful in explaining variation in these data, both for annual and monthly time series. Of the variables examined, it appears that the relative price of energy is a highly significant factor in accounting for the difference between actual industrial energy intensity and that which might have been expected had pre-1973 trends continued.
Energy conservation presents major opportunities to industry, both to improve its energy efficiency (hence its competitiveness and profitability) and to supply services and equipment. There are vast markets, both in the United Kingdom and overseas, but there are also barriers. There is reluctance on one hand to make new investment on the scale required. On the other hand, the problems of meeting a fragmented new demand are complicated by the fragmentation of the conservation supply industry. This calls for a new coherent, and innovative approach by both the conservation supply industry and the financial institutions. 3 tables.
The world steel industry and market and the current status and prospects for the Japanese steel industry are discussed with particular reference to China, Europe, and the US. Trends in coking coal supply from Australia, Canada, and Mongolia and changes in demand for hard and semi-soft coking coals are considered. Canadian coal plays a significant role in the hard coking coal and PCI coal markets. This is expected to continue. Emerging concerns include the strong Canadian dollar and increases in fuel and materials costs. Canadian suppliers are asked to improve efficiencies, be competitive in the overall coal chain, and diversify their PCI coal reserves. 14 figs.
This essay focuses on the major industrial changes from the late 1950s onwards in the industrial basins from the Nord/Pas-de-Calais to the Ruhrgebiet. The notion of industrial redeployment (reconversion industrielle) is critically analysed in the framework of European integration. The comparative approach highlights the importance of the time-space dimension which differs from one basin to the other. The diverse individual and collective actors also were in command of different power resources according to the various state traditions. The European Community, however, appears to have played an increasing role, culminating at the time of the steel industry crisis (1975-1985).
...The British Furniture Confederation, the trade association representing the UK furniture manufacturing industry, is delighted to announce that the A FIRA - Furniture ...Group reformed The British Furniture Confederation, the trade association representing the UK furniture manufacturing industry, is delighted to announce that the All-Party Parliamentary ...
The objective of the program is to develop technology that results in economical, industry produced, and commercially marketable wind energy systems. The purpose of the VAWT Design Technology Seminar for Industry was to provide for the exchange of the current state of the art and predictions for future VAWT technology. Emphasis was placed on technology transfer on Sandia's technical developments and on defining the available analytic and design tools.
Motivation is given for a technique to more thoroughly test semiconductor equipment control systems. A description is given of a simulator-based control system testing technique. Potential benefits that could be realized by using this technique in the semiconductor industry as well as benefits documented by using this technique in other industries are described. Specific requirements for using the technique in the semiconductor industry are outlined. A summary of a survey of nine commercial simulation systems is given. Finally, the outcome of the survey is compared with the requirements for using the technique.
Vietnam is beginning its industrialization process, and it currently lacks the capital necessary for expensive pollution control and treatment systems. Pollution strategies are critical for the country. This study evaluates the present status of industry and the pollution problems associated with industrial development in Vietnam. The purpose of the study is to identify sectors that may have potential for promoting cleaner production practices. 4 refs.
The bibliography contains citations concerning industrial uses and design of microwave heating equipment. Included are heating and drying of paper, industrial process heat, vulcanization, textile processing, metallurgical heat for sintering and ceramic manufacturing, food processing, and curing of polymers.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
This product provides detailed data and graphics on airborne and liquid effluent releases, fuel oil consumption, and water usage for the calendar year 1990. It summarizes industrial waste data records compiled since 1971 for the Idaho National Engineering Laboratory (INEL). The data presented are from the INEL Industrial Waste Management Information System (IWMIS).
This paper very briefly outlines hazardous waste management issues, including regulations, in Mongolia. Air, water, and soil pollutants are identified and placed in context with climatic, social, and economic circumstances. The primary need identified is technology for the collection and disposal of solid wastes. Municipal waste problems include rapid urbanization and lack of sanitary landfills. Industrial wastes of concern are identified from the mining and leather industries. 4 refs., 2 tabs.
This document presents the activity of KiloFarad International (KFI), a trade association for the promotion of the interests of the international ultra-capacitor industry through education and representation. KFI provides a forum for the ultra-capacitor industry to work on non-competitive activities (standards, working groups, test procedures etc..). The rest of the document presents some informations about ultra-capacitors technology and some advanced applications in the automotive and telecommunication industries. (J.S.)
Abstract The success of software projects is quite subjective in nature and is fettered by many risks, the perception of which varies from individual to individual and largely depends on the demographic characteristics of the executives and even the characteristics of the project. This study aims to identify and gauge the software risk dimensions and analyze the differences of perception among executives toward software risks. The contributions of this study untangle the issues underlying risks in the software industry and associates these issues with the perception of the -human- factor present in the industry.
Contains Executive Summary and Chapters on: Energy and the Internet; Internet Developments; Search Guide; Oil and Gas Industry; Electricity and Utilities; Nuclear Energy; Coal Industry; Alternative Energy; Government and Supranational Agencies; Research Institutions and Universities; Energy Statistics; Commodity Pricing and financial Markets; Company Information; Country Information; Associations; Engineering; Environment; Patents, Trademarks and Standards; News; Industry Events; Miscellaneous. (Author)
Key elements in strategic planning in the nonferrous mining industry are discussed. Included are price forecasting, financial planning, government relations, research and development, and exploration. Financial planning is discussed in terms of 1) forecasting of earnings, 2) investment policy and 3) tax planning. Costs of environmental liabilities are expected to have a major impact on the industry. (JMT)
A brief overview is given of the developments in the Dutch offshore industry where new offshore sites appear to be retrofitted or recycled platforms and contractors take over the work from petroleum companies (e.g. as so-called Floating Production Storage Offloading or FPSO). It is expected that in ten years from now a large number of oil platforms will be disappeared or transported to the Chinese Bohai Sea where a new oil field will be explored.
The EPA proposed effluent limitations guidelines and standards for the offshore segment of the oil and gas industry on August 26, 1985. On November 26, 1990, and March 13, 1991, the Agency reproposed effluent limitations guidelines and standards for both drilling and production wastes. The report is primarily concerned with the total annualized cost incurred by the offshore oil and gas industry in complying with the regulations.
The bibliography contains citations from a worldwide literature survey pertaining to the uses of activated charcoal in industry as well as in the laboratory, including its use in air pollution, chemical adsorption, radioactive waste adsorption, electrochemistry, industrial waste treatment, and the mining industry. (This updated bibliography contains 92 citations, 12 of which are new entries to the previous edition.)
Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially {sup 90}Sr and {sup 137}Cs are dominant contributor nuclides until 30 years and especially {sup 90}Sr and {sup 137}Cs have the highest activity and decay heat than other LLFP. In this study, recovery of {sup 90}Sr and {sup 137}Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 ...
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 after 1000 years ...
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyro-processing. In the assessment of long-lived fission products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02 E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26 E+05 after 100 years cooling, 1.97 E+04 after 300 years cooling, 9.52 E+03 after 1000 years ...
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low temperature cooling ...
The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the magnets and control dewar; (3) the control dewar and ...
The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...
The objective of the project was to provide a readily understandable and usable methodology for preliminary analysis of the economic benefit that can accrue from the use of thermal energy storage for building heating and cooling. The procedure was to be capable of providing an estimate of cooling plant and storage size, as well as the monthly savings that can be saved. The research focused on the development of a procedure for a limited class of commercial and institutional buildings in North Carolina. A simplified procedure for analyzing the potential for using thermal energy storage (TES) in such buildings in North Carolina was developed. The procedure developed consists of charts and nomographs that can be used for estimating the size of TES systems, and for estimating the monthly demand savings. The monthly demand savings can be combined with the applicable rate schedule to determine the annual cost savings. An overview of the procedure and ...
A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100/sup 0/C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300/sup 0/ to 1375/sup 0/C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on ...
A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100"0C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300"0 to 1375"0C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on mechanical ...
This report has reviewed the construction of a cooling tower for the K reactor at the DOE Savannah River Site in Aiken, South Carolina. It has been found that the cooling tower would prevent further destruction of cypress and tupelo trees, would maintain a more consistent flow from site streams, and would allow earlier recovery of stream corridors inside a portion of the site. About 630 acres of wetlands have already been affected by the hot water discharged by the K reactor during the past 35 years. GAO believes that about 10 to 12 acres of additional damage would be prevented by the tower for every year the reactor is operated, and if current plans for re-start and retirement of the reactor are followed, less than 100 acres would be preserved. As requested, GAO also identified an example of a project that could be funded as compensation to the public for the damage the K reactor would do if Congress exempted it from the Clean Water Act and ...
The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the flow rate and the coolant temperature during natural circulation ...
Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured ...
This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental facilities, and analysis with thermal hydraulic system codes have demonstrated the ...
The design and performance of small incinerators used at the Mound Laboratory for the disposal of explosives are described. These units, which cost less than $1000 each, are about the size of a 55-gal drum, have water jackets for cooling, and have provided a flexible, efficient, and clean burning explosives disposal unit. (LCL)
In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is supported by an integrated analysis of the ...
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, besides offering ...
Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts containing circulating ...
Purpose: To effectively cool the reactor core in a steam atmosphere by upwardly directing several of spray nozzles attached to a ring header thereby increasing the flying distance of the spray. Constitution: Ring headers in two upper and lower stages are disposed above the outer circumference of a reactor core and each of the ring headers is mounted with spray nozzles. Among the spray nozzles, at least several nozzles mounted to the ring header at the lower stage are directed such that the center axis for each of the nozzle is raised above the horizontal axis and other several nozzles are mounted with the nozzle center axis directed downwardly from the horizontal axis. Accordingly, even if collapsing phenomenon occurs in the jetting stream due to the condensation in the steams that forms the operation atmosphere of the reactor core spray cooling device, a sufficient amount of emergency cooling water can be distributed over ...
The goal of this study was to evaluate topics used to troubleshoot circuit boards with known or suspected thermally intermittent components. Failure modes for thermally intermittent components are typically mechanical defects, such as cracks in solder paths or joints, or broken b...
For sufficiently cool remote gases, the cylindrical stretched flame shows classical ignition-extinction behavior. For remote gas temperatures close to the adiabatic flame temperature, the flame response is qualitatively different, with negative flame speed solutions which may be physically accessible.
To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features ...
The feasibility study on conceptual design methodology for accelerator-driven sodium-cooled sub-critical transmutation reactors has been conducted to optimize the design parameters from the scale laws and validates the reactor performance with the integrated code system. A 1000 MWth sodium-cooled sub-critical transmutation reactor has been scaled and verified through the methodology in this paper, which is referred to Advanced Liquid Metal Reactor (ALMR). A Pb-Bi target material and a partitioned fuel are the liquid phases, and they are cooled by the circulation of secondary Pb-Bi coolant and by primary sodium coolant, respectively. Overall key design parameters are generated from the scale laws and they are improved and validated by the integrated code system. Integrated Code System (ICS) consists of LAHET, HMCNP, ORIGEN2, and COMMIX codes and some files. Through ICS the target region, the core region, and ...
Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that ...
Results of feasibility experiments for determining the mineral content of individual stains on special Sensitized Paper are presented. The stains were formed on the paper by the impaction of laboratory generated salt water droplets. Of the techniques exam...
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
Remote sensing data over North America document the ubiquity of secondary aerosols resulting from a combination of primary biogenic and anthropogenic emissions. The spatial and temporal distribution...Full Text Available
Air conditioning of urban electric cars by Peltier effect is simulated. Advantages (noise, simplicity of construction and of regulation, good heating performances...) and disadvantages (cooling performances lower than actual compressors, actual costs...) are presented. (A.B.). 8 refs., 5 figs.
We investigate the thermodynamic and chemical structure of the intracluster medium (ICM) across a statistical sample of 20 galaxy clusters analysed with the Chandra X-ray satellite. In particular, we focus on the scaling properties of the gas density, metallicity and entropy and the comparison between clusters with and without cool cores (CCs). We find marked differences between the two categories except for the gas metallicity, which declines strongly with radius for all clusters (Z ~ r^{-0.31}), outside ~0.02 r500. The scaling of gas entropy is non-self-similar and we find clear evidence of bimodality in the distribution of logarithmic slopes of the entropy profiles. With only one exception, the steeper sloped entropy profiles are found in CC clusters whereas the flatter slope population are all non-CC clusters. We explore the role of thermal conduction in stabilizing the ICM and conclude that this mechanism alone is sufficient to balance ...
IntroductionA rare side effect of antipsychotic medication is neuroleptic malignant syndrome, mainly characterized by hyperthermia, altered mental state, haemodynamic dysregulation,...Full Text Available
Profound myocardial hypothermia (below 17° C, and more often around 12° C) is imperative in myocardial protection while the aorta is cross-clamped. Based on our experience in...Full Text Available
... At the Vintage at Goodwood festival we're curating this summer, we intend to demonstrate how sustainability can be cool without being hippy in 2010. It really can - I'm the living embodiment of that . . .\\
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.
Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling ...
A method of making high strength coke briquettes suitable for use as blast furnace coke comprising, (A) providing coal, (B) heating the coal at a temperature at or above the softening point of the coal to form partially carbonized char, (C) cooling the partially carbonized char below the softening point of the coal, (D) mixing the cooled partially carbonized char and tar to form a mixture of tar and partially carbonized char, (E) briquetting the mixture of tar and partially carbonized char to form briquettes of tar and partially carbonized char, (F) calcinating the briquettes to form high strength briquettes.
Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.
It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.
Everyone is developing iPhone applications, and it's clear why. The iPhone is the coolest mobile device available, and the App Store makes it simple to get an application out into the unstoppable iPhone app market. With hundreds of thousands of app developers entering the game, it's crucial to learn from those who have actually succeeded. This book shows you how some of the most innovative and creative iPhone application developers have developed cool, best-selling apps. Not only does every successful application have a story, but behind every great app is excellent code. In this book, you'll
Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)
This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.
Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.
An apparatus is provided for rapidly restarting the flow of coolant through the cold electromagnetic shield of a superconducting rotor following a thermal transient episode. A vortex diode inhibits coolant flow in the undesirable reverse direction and encourages the reestablishment of a normal thermosyphon cooling loop flow quickly following the termination of a thermal transient such as that caused by transmission line faults. The present invention requires no moving parts and may therefore be permanently sealed in the superconducting rotor without risk of costly repair efforts caused by components failure.
Preliminary experiments have been performed to investigate the effects of radiative cooling on plasma jets. Thin (3 um - 5 um) conical shells were irradiated with an intense laser, driving jets with velocities > 100 km/s. Through use of different target materials - aluminium, copper and gold - the degree of radiative losses was altered, and their importance for jet collimation investigated. A number of temporally resoved optical diagnostics was used, providing information about the jet evolution. Gold jets were seen to be narrower than those from copper targets, while aluminium targets produced the least collimated flows.
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
The high temperature gas-cooled test reactor HTR-10 achieved the first criticality in last December in Institute of Nuclear Energy Technology of Tsinghua University in Beijing. Fuji Electric and Nissho Iwai have a cooperative information exchange agreement on the commercialization of the HTGRs with INET, and held an information exchange meeting in last March in INET. INET has started a study on the modification of the HTR-10 to couple with gas turbine system and a pre-feasibility study on the commercial HTGR under the cooperation with China State Power Company. The experiences and abilities of INET in the field of the HTGR and the aggressive plan for commercialization of the HTGR in China are summarized and discussed. (author)
Within the framework of the EU power plant conceptual study (PPCS), a modular He-cooled divertor concept with integrated pin array (HEMP) is being developed at the Forschungszentrum Karlsruhe. The design goal is to achieve a high heat flux of at least about 10-15 MW/m"2, which is proposed for a near-term reactor model like DEMO. The development and optimization of the divertor concept require a close link between the main issues: design, analyses, materials and fabrication technology, and experiments with feedbacks between them to be accounted for. Design-specific requirements on materials and fabrication issues will be discussed.
Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.
The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.
Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).
The renewed interest for using wind energy commercially is not more than twenty-five years old. From an experimental stage of turning wind energy into electricity in the 1970s, a new industry for producing standardised windmills gained foothold in the beginning of the 1980s and since then it has developed rapidly through the 1980s and the 1990s. The Danish innovators of the new windmill technology have been the pioneers behind this development, and Denmark has succeeded in acquiring a first mover advantage on the world market. This position has been maintained and at present Denmark satisfies more than half of the world market's demand for windmills. There are at least two reasons for this pioneering position of the Danish windmill industry. First, Denmark is by nature very `abundant' in wind energy due to its geographical position at the nexus between the Gulf Stream and the European continent. The windy climate makes given ...
The renewed interest for using wind energy commercially is not more than twenty-five years old. From an experimental stage of turning wind energy into electricity in the 1970s, a new industry for producing standardised windmills gained foothold in the beginning of the 1980s and since then it has developed rapidly through the 1980s and the 1990s. The Danish innovators of the new windmill technology have been the pioneers behind this development, and Denmark has succeeded in acquiring a first mover advantage on the world market. This position has been maintained and at present Denmark satisfies more than half of the world market's demand for windmills. There are at least two reasons for this pioneering position of the Danish windmill industry. First, Denmark is by nature very 'abundant' in wind energy due to its geographical position at the nexus between the Gulf Stream and the European continent. The windy climate makes given technologies of ...
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the ...
An experimental program has been conducted to determine the feasibility of natural convection cooling of a reactor following a beyond-design-based accident. The particular application under consideration was the heavy-water new production reactor. The questions to be resolved include the verification that a natural convection cooling pattern would be established and the determination of the power limit for which convective cooling will occur for a significant period of time. In the experiment, the reactor configuration was simulated using small-diameter vertical heated tubes in parallel with a large-diameter bypass line. Following a loss-of-flow event, the flow in the bypass line will reverse direction and pass through the heated channel by means of natural convection. If, however, the channel power is too high, void formation will block the channel and prevent the reverse flow pattern from occurring. The test procedure ...
This article identifies the key role of the sugar industry in the rural development of developing countries. The Indian sugar industry, already second largest among the country`s processing industries, shows even greater potential, according to the Plan Documents (shown in a table). The potential of waste heat in sugar processing plants, which produce white crystal sugar using the double sulphitation clarification process, is estimated at 5757.9 KJ/kg of sugar. Efficient waste heat recovery (WHR) systems could help arrest the trend of increasing production costs. This would help the sugar industry not only in India, but in many other countries as well. The innovative methods suggested and discussed briefly in this article include dehydration of prepared cane, bagasse drying, and juice heating using waste heat. These methods can reduce the cost of energy in sugar production by at least 10% and improve ...
Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety ...
In this paper we show that the recent model by Gilles Duranton [Duranton, G., 2007. Urban evolutions: The fast, the slow, and the still. American Economic Review 97, 197-221] performs remarkably well in replicating the city size distribution of West Germany, much better than the simple rank-size rule known as Zipfs law. The main mechanism of this theoretical framework is the "churning" of industries across cities. Little is known in urban economics about the determinants of local industry turnover so far. We present an empirical analysis of the excess churning index for West German cities, which describes the strength of intra-city industry reallocations over time. We find that urban growth and industry turnover are not notably correlated: Some, but not all fast-growing cities have notably...
Efforts in industry concerning pollution abatement up to nowadays were aimed at: solid particles contained in gaseous effluents, SO_2 effluent reduction, nitrogen oxide effluent limitation through combustion technology enhancement. Various CO_2 emission scenarios with different energy production means (same or increased nuclear plant number, energy consumption reduction) show that energy conservation schemes for the developed countries are the best solution to CO_2 control. Different solutions for greenhouse gas abatement from industrial plant are reviewed: effluent processing, burner technological enhancement, heat transfer optimization on industrial processes, computer assisted management for industrial processes, plasma technic for refining, substitution of gas to oil in chemistry, etc.
In this paper, an empirical model is developed for electricity consumption of the Jordanian industrial sector based on multivariate linear regression to identify the main drivers behind electricity consumption. In addition, projection of electricity consumption for the industrial sector based on time series forecasting is presented. It was found that industrial production outputs and capacity utilization are the two most important variables that affect demand on electrical power and the multivariate linear regression model can be used adequately to simulate industrial electricity consumption with very high coefficient of determination. To illustrate the importance of integrating energy efficiency within national energy plans, the impact of implementing high-efficiency motors was investigat...
Industrial premises bear more and more important thermal constraints which can commonly reach 150 W/m{sup 2} and more. The reason is the general development of automation and automatic devices and the better thermal insulation of buildings. Production quality requires also more and more strict ambient conditions (temperature, humidity, air quality, air flow etc..). Thus, the air-conditioning market in the industrial sector is more linked to economic factors such as productivity and profit than to thermal comfort of workers. However, the air-conditioning potentialities in the industrial sector remains under-exploited in France. This paper analyzes the reasons of this situation in terms of investments and equipments. (J.S.)
The slow or stagnant rate of nuclear power generation development in many developed countries over the last two decades has resulted in a significant shortage in the population of mid-career nuclear industry professionals. This shortage is even more pronounced in some specific areas of expertise such as radiological protection, waste management and decommissioning. This situation has occurred at a time when the renaissance of nuclear power and the globalization of the nuclear industry are steadily gaining momentum and when the industry's involvement in international and national debates in these three fields of expertise (and the industry's impact on these debates) is of vital importance. This paper presents the World Nuclear Association (WNA) approach to building and enhancing worldwide industry cooperation in radiological protection, waste management and decommissioning, which is ...
There are many factors contributing to the changes taking place within the electric utility industry. The environmental pressures on the industry are substantial and include the global warming issue, hazardous and nuclear waste challenges, air toxicities, and the electromagnetic field controversy. An issue of special concern is deregulation of the industry, which brought with it retail wheeling, wholesale wheeling, transmission access, and market-based pricing, all of which have greatly shaken the industry. The changes are expected to happen quickly. This is quite different from the 31 years it took to deregulate the telecommunications industry, the 15 to 20 years for railroads, the 9 years for the natural gas industry, and the 2 years for the airline industry. Historically there has been a general willingness among the utilites to share ...
In many ways, the Advanced Industrial Materials (AIM) Program underwent a major transformation in Fiscal Year 1995 and these changes have continued to the present. When the Program was established in 1990 as the Advanced Industrial Concepts (AIC) Materials Program, the mission was to conduct applied research and development to bring materials and processing technologies from the knowledge derived from basic research to the maturity required for the end use sectors for commercialization. In 1995, the Office of Industrial Technologies (OIT) made radical changes in structure and procedures. All technology development was directed toward the seven ``Vision Industries`` that use about 80% of industrial energy and generated about 90% of industrial wastes. The mission of AIM has, therefore, changed to ``Support development and commercialization of new or improved ...
Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of noncondensable gas is presented. The integral thermal-hydraulic tests simulate the small LOCA ...
The brain hypothermia treatment is an attractive therapy for the neurologist because of its neuroprotection in hypoxic-ischemic encephalopathy patients. The present paper deals with the possibility of controlling the brain and other viscera in different temperatures from the viewpoint of system control. It is theoretically attempted to realize the special brain hypothermia treatment to cool only the head but to warm the body by using the simple apparatus such as the cooling cap, muffler and warming blanket. For this purpose, a biothermal system concerning the temperature difference between the brain and the other thoracico-abdominal viscus is synthesized from the biothermal model of hypothermic patient. The output controllability and the asymptotic stability of the system are examined on the basis of its structure. Then, the maximum temperature difference to be realized is shown dependent on the temperature range of the apparatus and also on ...
This study deals with testing the capability of the code PARET to simulate natural convection cooling phenomena under different boundary conditions. In addition to applying and testing some new options related to simulation of the control rod movement and studying the reactivity effect of thermal expansion fuel elements. The experiments of the simple thermal hydraulic loop of Missouri university about natural cooling phenomena in two narrow paralled channels were used to validate the code. The study indicate good results regarding the distribution of coolant flux velocity and clad temperature. In particular the heat transfer coefficient of natural convection has been calculated in good agreement with the experiment. On the other hand, the core of MNSR reactor has been modelled to simulate the reactor dynamic behaviour under natural convection cooling conditions for different initial power level. The observed oscillation ...
This paper describes the use of numerical analysis for studying natural convection cooling systems for long term storage of heat producing radioactive materials, including special nuclear materials and nuclear waste. The paper explains the major design philosophy, and shares the experiences of numerical modeling. The strategy of storing radioactive material is to immobilize nuclear high-level waste by a vitrification process, convertion it into borosilicate glass, and cast the glass into stainless steel canisters. These canisters are seal welded, decontaminated, inspected, and temporarily stored in an underground vault until they can be sent to a geologic repository for permanent storage. These canisters generate heat by nuclear decay of radioactive isotopes. The function of the storage facility ventilation system is to ensure that the glass centerline temperature does not exceed the glass transition temperature during storage and the vault concrete temperatures ...
One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change the form of the core. Instead of employing the standard cylindrical geometry a plate shaped core should ...
A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is supported off the ...
This report contains the results of the Photovoltaic (PV) Industry Manufacturing Technology Assessment performed by the Automation and Robotics Research Institute (ARRI) of the University of Texas at Arlington for the National Renewable Energy laboratory. ARRI surveyed eleven companies to determine their state-of-manufacturing in the areas of engineering design, operations management, manufacturing technology, equipment maintenance, quality management, and plant conditions. Interviews with company personnel and plant tours at each of the facilities were conducted and the information compiled. The report is divided into two main segments. The first part of the report presents how the industry as a whole conforms to ``World Class`` manufacturing practices. Conclusions are drawn from the results of a survey as to the areas that the PV industry can improve on to become more competitive in the industry and ...
Program Review VI was comprised of six sessions, including an opening session, four technical sessions that addressed each of the major DOE research areas, and a session on special issues. The technical sessions were on Hydrothermal, Hot Dry Rock, Geopressured and Magma resources. Presenters in the technical sessions discussed their R and D activities within the context of specific GTD Programmatic Objectives for that technology, their progress toward achieving those objectives, and the value of those achievements to industry. The ''Special Issues'' presentations addressed several topics such as the interactions between government and industry on geothermal energy R and D; the origin and basis for the programmatic objectives analytical computer model; and international marketing opportunities for US geothermal equipment and services. The unique aspect of Program Review VI was that it was held in conjunction ...
In this paper, an empirical model is developed for electricity consumption of the Jordanian industrial sector based on multivariate linear regression to identify the main drivers behind electricity consumption. In addition, projection of electricity consumption for the industrial sector based on time series forecasting is presented. It was found that industrial production outputs and capacity utilization are the two most important variables that affect demand on electrical power and the multivariate linear regression model can be used adequately to simulate industrial electricity consumption with very high coefficient of determination. To illustrate the importance of integrating energy efficiency within national energy plans, the impact of implementing high-efficiency motors was investigated and found to be significant. Without such basic energy conservation and management programs, electricity ...
In Arabian Gulf industrial development, location factors show a favorable decline compared to the US as a result of industrial experience and the development of a data base on which to base comparisons. Petrochemical feedstocks and capital are the major resources for the Arabian states' investments. Cost analyses of ammonia, ethylene, and methanol show that production is only a little more than half the US production costs. While ethylene derivatives lose their economic advantage, they are more practical for marketing. Methanol production is developing slower than the production of ethylene derivatives because of competition in industrialized countries and low world prices for gas, but rising gas prices and the use of methanol for fuel are changing this situation. Comparisons of the growing aluminum industry with the investment and operating costs of other countries show that total operating ...
The reduction of emission from power plants of the public power industry inevitably leads to more and more residual products being obtained which require utilization. Traditionally, the building and building materials industry as well as, for a number of years, the gypsum industry have been the main customers processing these residual materials. To avoid having to tip them at landfills that are in short supply already, further uses are sought; so, for instance, in farming to ameliorate soil and fertilize plants. Relative to this subject, proposals are already available which are presented as lectures at the conference and discussed, together with practical knowledge and new investigation results. (BBR).
Three samples of dusts generated by the non ferrous metallurgical industries are treated between 200 and 800 degree centigree in controlled oxidizing and reducing atmospheres. The objective of this study is to recover the valuable metals from these wastes. The treatments of these solids under oxidizing conditions at 700 degree centigree are well adapted for two samples. The totality of valuable elements are concentrated in the treatments residues. The use of hydrogen at 600 degree centigree, permits the removal of up to 100 % of valuable metals contained in the treated industrial wastes. The recovery rate of valuable metals (Pb, Zn, Cu) as well as the Global Decontamination Factor are reported. (Author) 9 refs.
This paper presents anew design concept for a gamma irradiation plant for the continuous processing of pumpable liquids. Typical applications of such a plant include: the irradiation vulcanisation of natural latex rubber; disinfection of municipal sewage sludge for agricultural use; sterilisation of liquids in the pharmaceutical and cosmetics industries; industrial processing of bulk liquids The authors describe the design and operation of the latex irradiator now operating on a small production scale in Malaysia and proposed developments. The design allows irradiation processing to be carried out under an inert or other gaseous environment. State-of-the-art computer control system ensures the fully automatic processing operation needed by industrial computers.
Oil and gas industry is the largest user of radioactive materials in Nigeria. They make use of radiation generators, sealed and unsealed radioactive sources.Some of these are potentially dangerous to human health and environment if not properly controlled. here is also the need to maintain control over occupational exposures to radiation, as well as to protect the public and the environment through proper management of wastes that may be radiologically hazardous. To minimize these, effective regulatory infrastructure is being put in place.For a smooth take-off of the nuclear power program, the National Nuclear Regulatory Authority and other stake holders in the nuclear industry need to start to put together licensing procedure for these.
The subject of this paper is based on necessity to register occurrence in petroleum industry. Specifically we are making reference about Exploration and Production at petroleum industry, using a photography as job instrument. The PETROBRAS - Petroleo Brasileiro S.A., apply the photography resources in almost all service. The Campos basin Exploration and Production, responsible for 70% Brazil's petroleum production, utilizes photographies in many solutions. This paper is based on the following premises: the photography as register way; the information facility; the technical applies; the use of this register in the academic, scientific and operational ways. (author)
Saskatchewan boasts the greatest concentration of high-grade uranium of any place in the world. Properly managed, its current reserves of 238U can easily fuel the entire province for some 10,000 years (in comparison, the world's oil supplies may be gone in 100). It is likely that Saskatchewan, with all that uranium, can build an industry and renew Canada's nuclear dream. The authors believe in the value of nuclear energy, in general, and the value of uranium mining in Saskatchewan and other parts of the world, in particular. We also believe in the value of research, development, innovation and training in the nuclear industry and the uranium industry
The solar energy industry experienced unprecedented growth in the eight years from 2000 to 2007, with explosive growth occurring in the latter half of this period. From 2004 to 2007, global private sector investment in solar energy increased by almost twenty-fold, marking a dramatic increase in the short span of four years. This paper examines the timing, magnitude, focus and location of various forms of investment in the solar energy sector. It analyzes their trends to provide an understanding of the growth of the solar industry during the past eight years and to identify emerging themes in this rapidly evolving industry.
Laccases are increasingly being used in food industry for production of cost-effective and healthy foods. To sustain this trend widespread availability of laccase and efficient production systems have to be developed. The present paper delineate the recent developments that have taken place in understanding the role of laccase action, efforts in overexpression of laccase in heterologous systems, and various cultivation techniques that have been developed to efficiently produce laccase at the industrial scale. The role of laccase in different food industries, particularly the recent developments in laccase application for food processing, is discussed. PMID:21048859
Technical Development Document supporting proposed water discharge regulations for the Coal Mining Industry authorized by the Clean Water Act. Proposed regulations include revised best practicable technology limitations, best available technology limitations and new source performance standards for the Coal Mining Industry. Industry operations include: coal preparation and amillary operations, active mining, F bituminous, anthracite and lignite coal, and the reclamation phase of mining.
Lead-acid batteries, one of eight types, account for about 70% of annualized control costs facing the battery manufacturing industry as a result of EPA's guidelines. This report is the industry's response. It makes counter recommendations for effluent limitations, discusses selected control technologies and effluent limitations, makes control cost estimates, and provides an economic impact analysis and a benefits effectiveness analysis.
The bibliography contains citations concerning the properties, industrial uses and federal regulation of asbestos. The references explore advantages and disadvantages associated with use of industrial robots in areas containing high concentrations of asbestos dust, the use of water as a cutting tool to control the generation of asbestos dust, and governmental policies and attitudes relative to the health and welfare of workers subjected to asbestos. Thermal insulation properties, wear characteristics, high temperature capabilities, use as a reinforcement in composite materials, and asbestos substitutes are included. (Contains a minimum of 69 citations and includes a subject term index and title list.)
There have been many recent explosive advances in both IR and Raman spectroscopy which have developed in response to industrial problems of increasing complexity. Probably the biggest factor in these advances has been computerization, which has contributed not only to substantial improvements in data handling but to enormous gains in sensitivities of analyses as well. In this paper numerous examples of Raman and IR applications in industry are given using many of these recent advances, including in-situ techniques, microprobe analyses, unusual combinations of instruments - i.e., hyphenated methods - and new sample handling techniques. The bright future of FT-IR and Raman spectroscopy is also briefly discussed.
The Austrian sugar industry has developed a project for the manufacture of alcohol that is geared to the conditions in that country and is based on sugar beet as raw material. An alcohol production plant could be integrated in a sugar factory and operate all the year round at a capacity of 120,000 l/d. In this factory, the fermentation raw material would be in the form of green syrup (also thick juice if the need arose) and would be supplied from other sugar factories operating without molasses. The vinasse is to be concentrated and used or burnt. The project provides new possibilities for agriculture, and the sugar industry expects an improvement in plant utilization and a diversification.
... Tunnel Sensors Equipment on Environmental Expert Find and compare a variety of tunnel sensors equipment on the world's largest environmental industry portal. View ...
This article describes the disenchantment with electric cars after considerable hype by industry. Also discussed is why electric cars have failed to catch on.
from a broad range of sources including industrial and consumer products, food additives and drugs that never made it to the market to evaluate the predictive toxicity...
The article presents briefly the plans of the British Petroleum Oil Company for a new hydrogen power plant that includes an offshore platform in the North Sea.
The economic development of eastern Europe was associated during the last 15 years with the following average annual increases in energy consumption: Approximately 1% in the sectors industry, building and transport, almost 7% in the farming sector, approximately 3% in households, and nearly 4% in the municipal sector. This trend will not continue. As the economic system shifts from centrally planned to free economy and as the previously secluded economy is forced to face world market conditions as well as changed pars of exchange and conditions of payment, it not only experiences a transitory, sharp dip of economic growth in general but, in particular, drastic structural changes. - While there is to be expected, on the whole a slump in national economic growth, in tradiational branches of industry (e.g., metallurgy, the chemicals and textile industry) as well as in farming, such sectors as the service ...
depth timber industry experience with state-of-the-art ... difficult to find high-value pockets of timber (also known as timber stands ) to supply his ...
... and facilities; the physical processing of materials into products; and processes associated with ... area of bulk silicon prod! uction as wafer material has been omitted, in keeping with current ...
Streptococcus agalactiae continues to be a major cause of subclinical mastitis in dairy cattle and a source of economic loss for the industry. Veterinarians are often asked to provide information on...Full Text Available
The key to the future for electric utilities will not be found in legislation or regulation. Title VII of the Energy Policy Act of 1992 will prove to be just as ineffectual in improving the industry's position as was the Public Utility Regulatory Policies Act of 1978. These legislative palliatives, which produced so much commotion and so many reams of heated commentary, are largely irrelevant to a successful future for electric utilities. The key will be found in economics, not in law, and the future will lie in completing Thomas A. Edison's century-old vision for the industry, half of which the industry has heretofore ignored. The industry must embrace the complete vision and evolve from electric utilities into [open quotes]end-use energy utilities.[close quotes
This paper first discusses the challenge offered by natural and anthropogenic systems in all of their complexity and then indicates some areas of research in which specific scientific and technological needs are identifiable.
Safety in general and harmonization of International Maritime Organization rules on mobile offshore drilling rig operation in particular are discussed. The improvement of the industry's safety record is also discussed.
Objectives:Myocardial infarction (MI) is a leading cause of death in both the industrialized and developing countries globally. The economic evaluation of MI is undertaken...Full Text Available
In order to promote uniformity between jurisdictions, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has developed the National Directory for Radiation Protection, which is a regulatory framework that all Australian governments have agreed to adopt. There is a large and diverse range of industries involved in mining or mineral processing, and the production of fossil fuels in Australia. Enhanced levels of naturally occurring radionuclides can be associated with mineral extraction and processing, other industries (e.g. metal recycling) and some products (e.g. plasterboard). ARPANSA, in conjunction with industry and State regulators, has undertaken a review and assessment of naturally occurring radioactive material (NORM) management in Australian industries. This rev...
This document is a collection of spreadsheets detailing on a county by county basis the agricultural crop, agricultural wastes, municipal wastes, and industrial wastes of Virginia that are potential biomass energy sources.
This document is a collection of spreadsheets detailing in a county by county manner the agricultural crop, agricultural wastes, municipal wastes and industrial wastes in Florida that are potential biomass energy sources.
This document is a collection of spreadsheets detailing on a county by county basis the agricultural crop, agricultural wastes, municipal wastes and industrial wastes of Alabama that are potential biomass energy sources.
Total anthocyanins in different cultivars of mulberry were measured and a process for the industrial preparation of mulberry anthocyanins as a natural food colorant was studied. In 31 cultivars of mulberry,...Full Text Available
Jun 16, 2011 ... The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or ...
The photovoltaic (PV) industry is rapidly beginning to recognize the market potential of the buildings sector. New PV-for-buildings products have recently become commercially available, and numerous products that are under development will be introduced within the next 5 years. To ensure that these new products will be adopted and used in common building practices, the PV industry should recognize and address important buildings industry issues. These issues include building codes and standards, after-market servicing, education, and warranties and insurance policies. Photovoltaic systems are also still very expensive. The simplest method for increasing their value for a building is to decrease the building's electrical loads through energy efficiency and conservation. Meeting these goals can only be accomplished through partnerships with the U.S. Department of Energy (DOE), private industry, ...
ObjectivesTo assess the magnitude of cigarette smuggling after the market opened in Taiwan.MethodsReview of tobacco industry documents for references...Full Text Available
The battery manufacturing industry has not been immune to the impact of new technologies. How one company is adapting production techniques to meet the demand for better products is discussed.
... Waste Collection Systems Products and Equipment Find and compare a variety of waste collection systems products and equipment on the world's largest environmental industry portal. View product ...
...Air Quality Monitoring Networks Products and Equipment Find and compare a variety of air quality monitoring networks products and equipment on the world's largest environmental industry portal. ...
To quantify the opportunities for natural gas and identify technological advances needed to capture such opportunities, the mineral-wool industry was analyzed with respect to the principal companies, their capabilities, and markets. The mineral-wool industry is stable with a slightly declining market. Of its market segments, only commercial acoustic insulation (which is currently dominant) is likely to be affected by growth in the next ten years. The principal process is based on treatment of blast-furnace slags in a cupola furnace using coke as the fuel and reducing agent. Expanded use of gas, as a substitute for coke, would eliminate environmental problems and expand the latitude of suitable raw materials. The study provides insights into the mineral-wool industry and identifies factors that may constitute bases for future usage of natural gas.
Purpose - This paper seeks to deal with the history of Research and Development (R&D) management. It takes the history of the R&D Department of the Royal Philips Electronics of The Netherlands as an example to unravel the dynamics behind industrial R&D management. Design/methodology/approach - This paper is based upon historical and theoretical studies on industrial R&D institutions and research cultures. Findings - The paper proposes that the directors of the Philips R&D Department continually shaped and reshaped the organization in order to retain researchers with creative ideas, and to stimulate innovativeness. The R&D-management was the outcome of a search process that comprehended a mixture of scientific and industrial (management) skills, knowledge and experti...
Austria, Belgium, Czech Republic,. Denmark, Finland, France, Germany, .... Another study on ESA industry and partners: in relation with sustainability of ...
This is Japan Report with Science and Technology. It contains the issues with different topics on biotecnology, defense industry, nuclear engineering, Marine technology, science and technology policy.
... more so when that and he is leaving it with ... reminds me of the story about the sick man who ... fers based on industrial cooperation and the establish- ...
Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries
... accidentally released from a Soviet military laboratory (Meselson ... Robert Koch and Louis Pasteur worked to introduce ... species (eg, rat, mouse, dog, monkey) for ...
... Fuel Cell Technologies Equipment on Environmental Expert Find and compare a variety of fuel cell technologies equipment on the world's largest environmental industry portal. View ...
A growing number of environmental toxicants found in pesticides, herbicides, and industrial solvents are believed to have deleterious effects on development by disrupting hormone-sensitive processes....Full Text Available
... Environmental Assessment of Proposed Effluent Limitations Guidelines and Standards for the Meat and Poultry Industry Point Source; EPA-821-B-01-008; US ...
Raffle, P. A. B. (1974).British Journal of Industrial Medicine,31, 152-158. Disability rates of bus drivers. The proposal that ordinary driving...Full Text Available
The goal of this project was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and the upper use temperature by 86 to 140 degrees fahrenheit (30 to 60 degrees celsius). Meeting this goal is expected to result in energy savings of 35 trillion Btu/year by 2020 and energy cost savings of approximately $230 million/year. The higher-strength H-Series cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat treating industry, including radiant burner tubes. The project was led by Duraloy Technologies, Inc., with research participation by Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies.
This document includes the following topics: Background; Data Collection; Scope/Applicability of the Proposed Regulation; Description of the Industry; Industry Subcategorization; Pollutants of Concern for the Centralized Waste Treatment Industry; Pollutants Selected for Regulation; Wastewater Treatment Technologies; Regulatory Options Considered and Selected for Basis of Regulation; Long-Term Averages, Variability Factors, and Limitations and Standards; Cost of Treatment Technologies; Pollutant Loading and Removal Estimates; Non-Water Quality Impacts; Implementation; Analytical Methods and Baseline Values; List of Definitions; List of Acronyms; Appendix A--Pollutant Groups; Appendix B--Listing of Characerization Data From Non-Hazardous Oils Facilities; Appendix C--Listing of Daily Influent and Effluent Measuements; Appendix D--Facility-Specific Compliance Costs; Appendix E--Attachements to Chapter 10; and Appendix ...
... Corrosive Fumes Equipment on Environmental Expert Find and compare a variety of corrosive fumes equipment on the world's largest environmental industry portal. View ...
... Corrosion Inhibitors Equipment on Environmental Expert Find and compare a variety of corrosion inhibitors equipment on the world's largest environmental industry portal. View ...
... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...
Documents an early American industrial process of making blast furnace coke using techniques and equipment from the 19th century. Photographed at Bretz, WV.
This paper discusses geology, coalfields, coal quality, seams and strata, coal reserves, mining methods, production, coal liquefaction, and research on spontaneous combustion and methane explosions.
Many family physicians are considering purchasing a computer in the near future. This article explains some of the jargon of the computer industry and describes the various specifications that will...Full Text Available
Chemical leucoderma is an industrial disorder in developed countries and the common causative chemicals are phenols and catechols. Due to stringent controls and preventive measures the incidence has...Full Text Available
The next generation of particle accelerator is currently being designed at CERN. An understanding of the market forces in the computer industry will play a crucial role in the success of the project.
... Biogas Analyzers Equipment on Environmental Expert Find and compare a variety of biogas analyzers equipment on the world's largest environmental industry portal. View ...
The attendees this year included partic- ipants from space agencies, industry, and academia from Canada, the Czech Republic, France, Germany, Italy, Japan, ...
An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)
In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting behaviour predicted by ...
We calculate the structure of accretion disks around Kerr black holes for accretion rates 0.001 - 10 M_sun/s. Such disks are plausible candidates for the central engine of gamma-ray bursts. Our disk model is fully relativistic and treats accurately microphysics of the accreting matter: neutrino emissivity, opacity, electron degeneracy, and nuclear composition. The neutrino-cooled disk forms above a critical accretion rate that depends on the black hole spin. The disk has the ``ignition'' radius r_ign where neutrino flux rises dramatically, cooling becomes efficient, and the proton-to-nucleon ratio Y_e drops. Other characteristic radii are r_alpha where most of alpha-particles are disintegrated, r_nu where the disk becomes neutrino-opaque, and r_trap where neutrinos get trapped and advected into the black hole. We find r_alpha, r_ign, r_nu, r_trap and show their dependence on the accretion rate. We discuss the qualitative picture of accretion ...
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...
Shape optimization of heat transfer augmentation device employed in turbine blade internal cooling passage has been performed numerically using single as well as multi-objective optimization procedures. Polynomial response surface approximation method and multi-objective genetic algorithm are used for single and multi-objective optimizations, respectively. Problem to enhance heat transfer rate considering staggered dimples on single surface of cooling passage has been formulated, and Reynolds-averaged Navier-Stokes equations are solved to analyze the flow field and the heat transfer. Three design variables defining channel and dimple dimensions, and two objective functions related to Nusselt number and friction drag are employed. Latin hypercube sampling is used to generate sampling points in design space, and the evaluated objectives are used to generate a set of optimal designs. Optimal shapes show higher heat transfer rates in the case of ...
Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an overflow pipe in its ...
Therapeutic hypothermia is a promising method for controlling intracranial pressure (ICP) in severely brain-injured patients. However, clinical data regarding the effect of brain hypothermia on overall outcome of these patients is limited. This may be because there are specific pitfalls associated with the clinical management of induced hypothermia in patients with severe traumatic brain injury (TBI). These pitfalls may be avoided by preventing specific risk factors when cooling is induced and with rewarming. However, these risk factors have not been well systematically discussed in the literature. In this paper, three categories of clinical issues regarding the management of brain hypothermia are discussed: (1) stress-induced secondary brain injury mechanisms; (2) technical aspects of intensive care unit (ICU) cooling management; and (3) rewarming rates and methods. For patients with a Glasgow Coma Scale (GCS) score of less than 8, management ...
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...
The purpose of this paper is to assess a new local air coolers model in ISAAC 2.0, as ISAAC 1.0 could model local air coolers only at two locations. In the new model, local air coolers up to twelve locations could be handled. Large LOCA and loss of feed water sequences were selected for the model comparison. Two cases were analyzed with ISAAC 2.0: one with 6 local air coolers in one of the fueling machine room and in the steam generator room, respectively, and the other with 3 local air coolers at both fueling machine room and 6 local air coolers in the steam generator room. The study assumes that the safety systems such as emergency core cooling system, shield cooling system and moderator cooling system are unavailable. According to the ISAAC 2.0 results, the new local air coolers model showed almost no difference between two cases. Also it was found that as the location of LACs increased, the new model worked properly and ...
Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...
The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on governing equations, the heat transfer of ...
The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying levels.