WorldWideScience
1

Ramp-rate sensitivity of SSC dipole magnet prototypes  

Energy Technology Data Exchange (ETDEWEB)

One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A magnets. The behavior of ...

1994-07-01

2

Nb{sub 3}Sn LLNL cable test strand  

Energy Technology Data Exchange (ETDEWEB)

Axial strain characterization was completed for a Nb{sub 3}Sn conductor from Lawrence Livermore National Lab used in a transverse stress test of a cable-in-conduit conductor. The effect of axial strain on the critical current of the LLNL Nb{sub 3}Sn test strand was measured at magnetic fields from 8 T to 22 T. The conductor specifications are shown in Table 3, and the measured data are shown in Table 4. The data are presented graphically in Figs. 5 through 7. The I{sub c} and J{sub c} values are based on an electric field criterion (E{sub c}) of 2 {mu}V/cm. The zero-strain 12 T value of J{sub c} at 12 T was 0.39 GA/m{sup 2}. The irreversible strain limit was quite high, 1.0 strain, and the compressive prestrain was relatively low at 0.27%. Fracture strain was 1.10%.

1994-01-01

3

R and D for a single-layer Nb{sub 3}Sn common coil dipole using the react-and-wind fabrication technique  

Energy Technology Data Exchange (ETDEWEB)

A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight ...

2002-01-14

4

Method of fusing segments of armored logging cables  

Energy Technology Data Exchange (ETDEWEB)

The method is used for repairing armored logging cables. It consists of preparing armor, subsequent connection of current-conducting strands and wires of the armor, and laying of the armor. Sections of connecting the wires of the armor of the lower and upper layers are scattered over the length of the fused section of the cable. In order to improve the fault strength of the cable, the junctions of connection of the armor wires are scattered among themselves at a distance determined by the Euler formula, and thermal tempering of the wire sections is carried out near these junctions, and then the fused section of the cable is reinforced.

1982-01-01

5

Screening of Flexible Cables by Nonlinear Resistance ...  

Science.gov (United States)

... Abstract : Two traces in flexible cables used in the Milstar agile beam antenna system failed during acceptance testing. ...

1994-01-10

6

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). ...

2004-01-01

7

Long term accelerated aging tests on distribution cables under wet conditions  

Energy Technology Data Exchange (ETDEWEB)

Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.

1996-10-01

8

Eddy current inspection of superconducting cable during manufacturing  

Energy Technology Data Exchange (ETDEWEB)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current ...

1992-03-01

9

Eddy current inspection of superconducting cable during manufacturing  

International Nuclear Information System (INIS)

The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures is costly both financially and because of the time needed to recover from them. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers, which drastically reduce the mechanical integrity of the strand and thus of the cable itself. But because of the large volume of cable that will be manufactured, an automated flaw detection system that can inspect the cable and detect these types of defects will be needed. We have recently done an on-line experiment using an Eddy current system and specialized Eddy current probes to inspect ...

1992-03-04

10

Very high voltage cables with synthesis insulation; Les cables tres haute tension a isolation synthetique  

Energy Technology Data Exchange (ETDEWEB)

A historical review on insulated cables for power transmission, is presented, beginning with impregnated paper insulation, oil filled cables and natural rubber cables. High density and chemically reticulated polyethylene were then used for high voltage and very high voltage cables; the advantages of polyethylene compared to impregnated paper cables are discussed, which led to research programs at EDF on various themes concerning the optimization of polyethylene cables: dielectric properties and reliability, thermomechanical behaviour, thermal ageing of materials, testing methods (acceptance dielectric test and long duration temperature test); utilization of low- and high-density and chemically reticulated polyethylene for 225 kV cables is discussed

1997-06-01

11

Development of new 500kV laminated paper insulated self-contained oil-filled cable and its accessories  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development of cellulose paper/plastic film/cellulose paper laminate insulated Self-Contained 500 kV Oil-Filled (OF) Cable and its accessories. Dielectric loss of this new cable was confirmed to be about one third that of conventional kraft paper cable. Moreover, by employing the reduced insulation thickness of 25 mm rather than that of 33 mm, as is usual with conventional cables, the new cable could be made very compact, due to the high dielectric strengths of laminated paper. As a result, the shipping reel length of the new cable, which is about 10% lighter in total weight and 10% smaller in overall diameter than conventional cables, could be dramatically increased. The reliability and the stability of the new cable have been demonstrated by the successful completion of a one and a half year ...

1988-01-01

12

Oil-filled, multi-core cable with at least one conductor differing from others  

Energy Technology Data Exchange (ETDEWEB)

This patent discloses an oil-filled, multi-core, electric cable having three cores within a metal sheath suitable for underwater applications. Each core has a conductor surrounded by insulation and has substantially the same outer dimensions as the other cores. One conductor is made of copper and has a central oil duct. The other conductors are made of stranded aluminum wires in side-by-side and contacting relation and the ratio of the cross-sectional area of the metal of the copper conductor to the cross-sectional area of the metal of each aluminum conductor is the reciprocal of the ratio of the electrical conductivities thereof. One object of this invention is that of overcoming the drawbacks existing in the known oil-filled, multi-core cables, i.e. to provide cable which, in case of a rupture of the cable sheath, has fairly small leakages of insulating, fluid oil from the ...

1987-02-03

13

Evaluation of a solid hydrophone cable  

Energy Technology Data Exchange (ETDEWEB)

In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage ...

1982-07-01

14

A statistical evaluation of recent SSC conductors produced at IGC/ASI  

International Nuclear Information System (INIS)

One of the requirements for uniform field quality in the SSC dipole magnets is the consistency in the superconducting strand characteristics from start to finish to the production phase. As full scale production of strand and cable approaches, the consistency in performance of the early batches of conductor needs to be examined. A number of 300 mm billets have been manufactured at IGC with tight process controls. The performance of the final conductor in terms of piece lengths, current density, Cu/Sc ratio and wire diameter has been evaluated. The data are analyzed in order to understand the variations that are related to the conductor design and processing. In this paper the current density of the strand is examined over the length of the billet to determine inherent variability in the Nb/Ti alloy itself.

1990-09-24

15

Development of 275kV oil-filled cable insulated with polypropylene laminated paper (PPLP)  

Energy Technology Data Exchange (ETDEWEB)

In 1969, the authors started R and D on a polypropylene laminated paper (PPLP) as a new low-loss insulating paper for oil-filled (OF) cables. Through the material research and the trial manufacture of 275 kV OF cable and four years of long-term field test, PPLP has reached the stage of commercial use. This paper introduces a summary of the history of the development of PPLP, the characteristics of PPLP and cable, the results of long-term field test of 275 kV cable, and other relevant data.

1982-12-01

16

Evaluation of 230 kV HPFF pipe-type cable with wrinkled and creased insulating tapes  

Energy Technology Data Exchange (ETDEWEB)

Severe collapse wrinkles and circumferential creases were discovered in the cellulose paper insulating tapes of a newly installed IIPFF pipe-type cable during splicing and terminating. An evaluation program was developed to assess the electrical and mechanical integrity of the cable having wrinkled and creased insulating tapes. The test results indicated that the cable would perform satisfactorily in service.

1995-01-01

17

Evaluation of HVDC cables for the St. Lawrence crossing of Hydro-Quebec 500 kV DC Line. Part 1; Dielectric and accelerated aging tests on prototypes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.

1992-04-01

18

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric ...

1985-04-01

19

Polypropylene/paper laminates as high voltage power cable insulation  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to identify optimal laminate/oil combinations for low pressure oil filled and high pressure pipe-type cables, and to establish taping criteria under factory conditions. Laminates from two sources were evaluated in conjunction with Sun XX high viscosity mineral oil and Cosden 015SH polybutene oil for high pressure type cables, and Dussek TC-2288N mineral oil, Shell P2 dedecylbenzene and Chevron DF-100 alkylbenzene for low pressure oil-filled cables. Swelling tests, infrared analysis, dissipation and dielectric measurements, impulse tests and a taping trial were performed. It was found that there is no appreciable difference in performance of both laminates when tested on model cables in a variety of oils. Both types exhibited superior aging characteristics vis-a-vis cellulose paper when tested with ...

1983-08-01

20

MPS [More Power Submarine] cables could be MIND [Mass Impregnated Non-Draining Cable] blowing for 1200 MW links  

Energy Technology Data Exchange (ETDEWEB)

ABB High Voltage Cables AB started the MPS (More Power Submarine cables) project in 1993 with a view to exploring new technology opportunities. The goal is to design and type test a submarine HVDC cable for a capacity of 1200 MW at 600 kV. On the day before ABB announced its success in winning the contract for the world`s largest ever submarine HVDC link project for the gigantic Bakun project in Malaysia, ABB Power Systems described progress to date at a symposium in Karlskrona. The proceedings included a test demonstration on an extruded cable which eventually broke down at a stress of over 935 kV -not in the insulation itself but in the end terminations. The electric field was in excess of 200 kV/mm which is higher than ever before reported. (UK)

1996-07-01

21

Rehabilitation of a gassy low pressure liquid filled 115 kV cable  

Energy Technology Data Exchange (ETDEWEB)

The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined ...

1994-12-31

22

PILC cable technology and accessories  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it has proven to be ...

1996-08-01

23

A connecting coupling  

Energy Technology Data Exchange (ETDEWEB)

The flexible, insulated, single strand cables are electrically connected with a cylindrical polar tip (PN) by means of cylindrical and conical shafts for the polar tips, which enter the faces of the divided, multiwire strand, clamped by tension half couplings. The flat ends of the polar tips being joined are positioned in two concentric mandrel bushings, an internal fixed one and an external, axially movable bushing (PV). The internal bushing is rigidly attached to the end of the left polar tip and equipped with three or four rounded, radial openings, whose diameter is determined by the external diameter of the locking device hinges (ShF) of the connecting couplings. The right polar tip is equipped with an annular channel of trapezoidal section into which the locking device hinges enter. The external movable bushing on the right side has a conical turning and on the left, a cylindrical into which the cylindrical spring ...

1981-06-05

24

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

25

Back-up for high voltage cable pressurizing system  

Energy Technology Data Exchange (ETDEWEB)

A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.

1982-07-19

26

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe ...

1982-07-01

27

A. C. losses in the SSC high energy booster dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.

1991-06-01

28

Field validation of cable monitoring and rating system (CMARS) laboratory model. Semi-annual report, 1 May 1979-31 December 1979  

Energy Technology Data Exchange (ETDEWEB)

One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)

1980-01-01

29

Development of radial-flow type internally oil-cooled oil-filled cable  

Energy Technology Data Exchange (ETDEWEB)

A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.

1988-01-01

30

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

31

Increasing pipe-cable section lengths. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the results of an experimental program which developed a needed reliable data base on modern pipe-type cable construction from which designers can knowledgeably consider maximizing cable pulling lengths with resulting cost savings. The program comprised evaluations of available commercial constructions over the range of conductor sizes (both copper and aluminum) and insulation thicknesses in general utilization. The work focussed on determining the cable's performance under the three mechanical stress modes to which the cable is subjected during installation; (a) tension and elongation, (b) torsion and (c) sidewall (bearing) pressure in bends. Additionally, the program included experimentation to determine the effective coefficient of friction of the various combinations of modern skid wire materials and pipe filling oils used as lubricants with the ...

1983-03-01

32

A stand for testing supports  

Energy Technology Data Exchange (ETDEWEB)

The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.

1980-07-30

33

Test of use of MN-4 oil in 110 to 220 kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

Beginning in 1972 low-pressure cables filled with MN-4 oil produced by the Yaroslav Petroleum Processing Plant arrived at the Leningrad Cable Network of the Leningrad Rayon Power Administration. Lines formed with these cables have been successfully used. The parameters of the oil in them have not changed with respect to the values present when the lines were placed in operation. However, from here on filling in of the 110 to 220 kV input lines of low and high pressure will be accomplished with MN-4 oil produced by the Gorkiy Petroleum Processing Plant. Because petroleum from various fields and the properties of the oil produced from it are unlike, samples were taken from some elements of the lines filled in with MN-4 oil. The results of the tests are described.

1980-09-01

34

Multiple stress aging of solid-dielectric extruded dry-cured insulation systems for power transmission cables  

Energy Technology Data Exchange (ETDEWEB)

A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.

1994-01-01

35

Field-effect research at the High Voltage Transmission Research Center  

Energy Technology Data Exchange (ETDEWEB)

This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are ...

1991-02-01

36

Fiber optic quality assurance at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.

1981-01-01

37

Elastic flexural properties of multistranded stainless steel versus conventional nickel titanium archwires.  

Science.gov (United States)

Based on a recent investigation that modeled the elastic properties (ie, strength, stiffness and range) of multistranded wires made from linearly elastic materials, three-stranded (triple) and six-stranded coaxial (coax) stainless steel (SS) wires were compared to single-stranded (single) SS and conventional nickel titanium (NiTi) leveling wires. To measure Young's modulus of elasticity (E), flexural tests were performed with an Instron mechanical testing machine in a three-point bending arrangement having a span length of 8.9 mm or 12.5 mm. A strong correlation between wire stiffness and the area moment of inertia demonstrated that strand interaction was negligible at low activations and that E = 199 GPa was constant even for the heavily drawn coax strands. Using the Instron with an extensometer, the 0.1% yield strengths (sigma(YS)) of the ...

2002-08-01

38

Emergency ampacities of direct buried three phase underground cable systems  

Energy Technology Data Exchange (ETDEWEB)

A thermal model is formulated for the determination of the emergency transient ampacities of a three phase, horizontally spaced underground cable system. The model is based on a finite difference heat transfer analysis and the principle of superposition which permits the summation of the temperature rise of individual heat sources to eventually provide for the temperature rise of a multiple cable system. The thermal model is transformed into a complex computer program that is capable of calculating the real time cable temperature for any change in conductor current. The program is used to calculate the response of conductor temperatures caused by both ramp and step changes in currents for four conductor sizes between 4/0 and 1500 kcmil. The amount of time to reach conductor temperatures of 100/sup 0/C and 120/sup 0/C from a steady conductor temperature of 75/sup 0/C is calculated for the different conductor sizes and for ...

1983-07-01

39

Underground high-power transmission: first results of testing a 110 kV lowpressure oil-filled cable with a water cooled conductor in Berlin (West), Germany  

Energy Technology Data Exchange (ETDEWEB)

The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.

1982-07-01

40

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at ...

2000-05-01

41

Resistive cryogenic cable economic-viability evaluation. Final report, Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It ...

1980-03-31

42

Cost reduced inspection concept of PE/XLPE medium voltage cables; Kostensparende Zustandsanalyse an PE-/VPE-isolierten Mittelspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten ...

1997-12-15

43

Weld integrity of the superconducting cable aluminium jackets of W7-X  

British Library Electronic Table of Contents (United Kingdom)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...

2009-01-01

44

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach ...

1986-04-01

45

Evaluation of improvements in the installation of rural underground transmission lines: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.

1987-10-01

46

Fire preventive materials for nuclear power plants  

International Nuclear Information System (INIS)

With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with ...

47

Development of a tool to collect insulation oil in a cable connection box without interrupting power supply; Muteiden ni yoru cable setsuzokubakonai zetsuen`yu saishu kogu no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

While underground power transmission lines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that insulation oil can go through the oil collecting tool and gets collected. ...

1999-02-10

48

Weld integrity of the superconducting cable aluminium jackets of W7-X  

Energy Technology Data Exchange (ETDEWEB)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...

2009-06-15

49

Weld integrity of the superconducting cable aluminium jackets of W7-X  

International Nuclear Information System (INIS)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...

2009-06-01

50

White oils for high voltage cables  

Energy Technology Data Exchange (ETDEWEB)

S-120 white oils are used to impregnate insulation and fill high voltage wires. Cooling oil flows of specified viscosities can increase the load capacity of wires. White oils are studied for viscosities and dielectric properties. To meet requirements, S-220 type oils of different medium or low viscosities are tested. Capacity can be increased by viscosity adjustment. Tests were also made to select optimum stabilizing additives to keep low-viscosity.

1983-05-01

51

Development of 345-kV capacitive-graded joint. Final report  

Energy Technology Data Exchange (ETDEWEB)

The design of a 345-kV prefabricated capacitive-graded joint for oil-filled cables and the manufacture and testing of prototype joints are described. Tests on prototype No. 4 demonstrated the adequacy of the printed circuit design. It was not possible to consistently obtain high-quality capacitive sheets and substantial effort is required to remedy this problem. Advantages of these prefabricated joints are summarized, and specific recommendations are made for further development of the concept.

1980-09-01

52

Advanced power cable technology. Volume II. Present and future  

Energy Technology Data Exchange (ETDEWEB)

In this book an attempt has been made to describe the most recent information, but at the same time set out the fundamentals of cable technology in some depth. A focus is directed on general features of various kinds of cables. This book is written for cable engineers, and those interested in cable research, the book will also be useful to university students and management personnel interested in electric power engineering. This volume contains chapters on Present Cables and Their Improvement and New Types of Cables. (CS)

1983-01-01

53

An analysis of selected atmospheric icing events on test cables  

Energy Technology Data Exchange (ETDEWEB)

In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud ...

1996-12-01

54

Mesenchymal stem cell transplantation for diffuse alveolar hemorrhage in SLE  

British Library Electronic Table of Contents (United Kingdom)

Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...

2010-01-01

55

Biotin-labeled hairpin oligonucleotides: probes to detect double-strand breaks in DNA in apoptotic cells.  

UK PubMed Central (United Kingdom)

Hairpin oligonucleotides were synthesized with stems ending in a double-stranded structure, which can be ligated to double-strand breaks in DNA, and with loops that contain nucleotides modified by the...Full Text Available

1998-04-01

56

A rapid and efficient method for region- and strand-specific mutagenesis of cloned DNA.  

UK PubMed Central (United Kingdom)

The single-stranded viral DNA of an M13 phage recombinant containing the early promoter region of SV40 was hybridized with linear, double-stranded replicative form DNA of a related M13 phage containing...Full Text Available

1982-01-01

57

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

Energy Technology Data Exchange (ETDEWEB)

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power ...

1983-12-01

58

Oceans 82 conference record: Industry, government, education. partners in progress  

Energy Technology Data Exchange (ETDEWEB)

Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.

1982-01-01

59

Neurobrucellosis in Stranded Dolphins, Costa Rica  

UK PubMed Central (United Kingdom)

Ten striped dolphins, Stenella coeruleoalba, stranded along the Costa Rican Pacific coast, had meningoencephalitis and antibodies against Brucella spp. Brucella...Full Text Available

2008-09-01

60

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between ...

1984-07-01

61

A review of the technical development of electric cables in the history of the Berlin electric utilities. Ein Rueckblick auf die Berliner Kabeltechnik aus Sicht der Energieversorgung  

Energy Technology Data Exchange (ETDEWEB)

The technical development of electric cables in the history of the Berlin electric utilities looks back on more than one century of continuous progress from jute-insulated direct-voltage cables, to 30 kV paper-insulated mass-impregnated cables, 110 kV plastic-insulated cables, 380 kV oil-filled cables, and 380 kV XLPE cables which are increasingly used today. A brief review informs about the major stages of power cable development. (orig.).

1992-05-15

62

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from ...

1994-01-01

63

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

Energy Technology Data Exchange (ETDEWEB)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging ...

1992-10-01

64

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging ...

1992-01-01

65

HVDC submarine cables for the Hokkaido Honshu linkage  

Energy Technology Data Exchange (ETDEWEB)

The direct-current submarine cable interconnecting Hokkaido and Honshu (hereafter called HH linkage) is an example of installation of an undersea cable for long-distance power transmission crossing a sea strait. In particular, the feature of this interconnection is that an oil-filled (OF) cable is used for the high-voltage side with crosslinked polyethylene (XPLE) cable adopted for the return to comprise a conductor return system. The details of the facilities, especially the design of the OF submarine cable are described. 3 refs.

1981-04-01

66

Experience acquired in the carrying out of the long duration test on XLPE-insulated, mediumvoltage cable according to DIN VDE 0276; Erfahrungen bei der Umsetzung der Langzeitpruefung an VPE-isolierten MS-Kabeln nach DIN VDE 0276  

Energy Technology Data Exchange (ETDEWEB)

Long duration investigations on XLPE-insulated, medium-voltage cable have been intensively carried out by producers, institutes and users for decades. These tests have concentrated on cable ageing especially under the influence of water. About six years ago, a standard test procedure was developed based on comprehensive know-how. This test procedure is now included in DIN VDE 0276-620. In the following text, experience gained during testing and while performing tests in numerous laboratories is reported, and a summary of the test results is given. (orig.) [Deutsch] Langzeituntersuchungen an VPE-isolierten Mittelspannungskabeln, die sich mit der Alterung der Kabel, besonders unter dem Einfluss von Wasser beschaeftigen, wurden seit Jahrzehnten durch Hersteller, Institute und Anwender intensiv betrieben. Basierend auf ...

1997-06-30

67

Elastic properties of alternative versus single-stranded leveling archwires.  

Science.gov (United States)

The strength, stiffness, and range of single-stranded stainless steel (SS) and superelastic nickel-titanium (NiTi) archwires were compared with those of alternative leveling products, including nylon-coated and multistranded wires. Wire cross-sections were photographed after being potted in polymer, ground, and polished. Because the rectangular wires had rounded or beveled corners, gravimetric measurements and specific gravity calculations quantified the actual polygonal cross-sectional areas versus the ideal rectangular cross-sectional areas. Beveling reduced the cross-sectional areas by 7% to 8%; this decreased the wire stiffnesses by 15% to 19%. Using a testing machine, we measured the yield strengths, the elastic limits, and the ultimate tensile strengths in tension, and wire stiffnesses in 3-point bending. From cyclic loading tests, the elastic limits of the superelastic NiTi wires were approximately 90% and 45% of ...

2002-11-01

68

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

69

Checking the condion of 500 kV cable lines by chromatographic analysis of gases dissolved in oil  

Energy Technology Data Exchange (ETDEWEB)

A chromatographic technique is described for checking the condition of cable insulation by analyzing cable oil for the gases that are typical of defects in power transformers: carbon dioxide, acetylene, methane and ethylene. This technique was successfully used for predicting breakdown of insulation on KL-2 cable at one of the hydroelectric plants of Kirgizglavenergo power grid 1.5 months in advance. The presence of the above-mentioned gases in cable oil can provide a signal for monitoring the state of cable insulation. Further research is needed in addition to more operational experience to work out criteria for objective evaluation of the state of cable lines.

1980-03-01

70

Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line  

Energy Technology Data Exchange (ETDEWEB)

A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the field tests. As a result, a close accordance was found between ...

1982-08-01

71

Tritium contamination and decontamination study on materials for ITER remote handling equipment  

Energy Technology Data Exchange (ETDEWEB)

Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO{sub 2} containing alkaline barium glass (NB), CeO{sub 2} containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm{sup 2}, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm{sup 2}, respectively. The tritium concentration in an electric ...

2001-09-01

72

Tritium contamination and decontamination study on materials for ITER remote handling equipment  

International Nuclear Information System (INIS)

Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO_2 containing alkaline barium glass (NB), CeO_2 containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm"2, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm"2, respectively. The tritium concentration in an electric ...

2001-09-01

73

Oil cable pumping plant. Pumpestasjon  

Energy Technology Data Exchange (ETDEWEB)

The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.

1988-12-27

74

110-500 kV high-pressure cables  

Energy Technology Data Exchange (ETDEWEB)

The use of oil-filled high-pressure electric cables has increased significantly. In recent years, the electric cable industry has developed new designs, manufacturing technology, and has mastered the production of 110 to 220 kV cables without using a temporary lead sheath. The design, fabrication, and performance of high-pressure electric cables for power systems are discussed.

1982-08-01

75

Proceedings: Water treeing and aging  

Energy Technology Data Exchange (ETDEWEB)

This report presents the record of the workshop Water Treeing and Aging.'' The workshop was held in Phoenix, Arizona on December 9--11, 1990 and was sponsored by the Distribution Program of the Electrical Systems Division of the Electric Power Research Institute (EPRI). Attendance at the workshop was by invitation only. Twenty two attendees from seven countries, from universities, research organizations, electric utilities and polymeric materials suppliers took part in this workshop. The workshop was designed to assess progress in the understanding of water treeing phenomena and polymeric cable insulation aging since the last meeting of a similar forum of experts, which was organized by the Office of Exploratory Research of EPRI in December 1985. The objective of the present workshop was to assess progress and to provide direction for further studies in this field. The discussions covered a wide range of subjects including water tree structure, ...

1991-10-01

76

Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses  

International Nuclear Information System (INIS)

We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.

1984-11-01

77

Investigation of anomalous CXR response of filled cables  

Energy Technology Data Exchange (ETDEWEB)

An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.

1982-12-01

78

Improving performance of e. h. v. cable systems  

Energy Technology Data Exchange (ETDEWEB)

Following an earlier article on developments to enhance the reliability of supertension oil filled cables and accessories, changes are described in design and installation of complete cable systems which have similarly improved operating performance.

1983-03-04

79

Mathematical model of heat transfer for bloom continuous casting  

British Library Electronic Table of Contents (United Kingdom)

A mathematical model for heat transfer during solidification in continuous casting of automobile steel, was established on researching under the influence of the solidifying process of bloom quality of CCM in the EAF steelmaking shop, at Shijiazhuang Iron and Steel Co. Ltd. Several steel grades were chosen to research, such as, 40Cr and 42CrMo. According to the results of the high temperature mechanical property tests of blooms, the respective temperature curves for controlling the solidification of different steels were acquired, and a simulating software was developed. The model was verified using two methods, which were bloom pinshooting and surface strand temperature measuring experiments. The model provided references for research on the solidifying process and optimization of a secon...

2008-01-01

80

Failure modes of safety-related components at fires on nuclear power plants; Saekerhetsrelaterade systemkomponenters felmoder vid brand paa kaernkraftverk  

Energy Technology Data Exchange (ETDEWEB)

Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in this report. Also a summary of results from ...

2000-03-01

81

Translation Elongation Factor 1A Facilitates the Assembly of the Tombusvirus Replicase and Stimulates Minus-Strand Synthesis  

UK PubMed Central (United Kingdom)

Replication of plus-strand RNA viruses depends on host factors that are recruited into viral replicase complexes. Previous studies showed that eukaryotic translation elongation factor (eEF1A) is one...Full Text Available

2010-11-01

82

The first international standard for antibodies to double stranded DNA.  

UK PubMed Central (United Kingdom)

This paper announces the availability of the first international standard for anti-double-stranded DNA (anti-dsDNA). The material, coded Wo/80, was obtained after recalcification of plasma taken from...Full Text Available

1988-09-01

83

Strand displacement synthesis capability of Moloney murine leukemia virus reverse transcriptase.  

UK PubMed Central (United Kingdom)

The accepted model of retroviral reverse transcription includes a circular DNA intermediate which requires strand displacement synthesis for linearization and creation of an integration-competent, long...Full Text Available

1994-08-01

84

Selecting Folded Proteins from a Library of Secondary Structural Elements  

UK PubMed Central (United Kingdom)

A protein evolution strategy is described by which double-stranded DNA fragments encoding defined E. coli protein secondary structural elements (α-helices, β-strands...Full Text Available

2008-01-09

85

Naturally occurring double-stranded RNA and immune responses. III. Immunogenicity and antigenicity in animals.  

UK PubMed Central (United Kingdom)

Naturally occurring, double-stranded RNA (ds-RNA)) was immunogenic when injected into mice, rats, guinea-pigs, rabbits, dogs and baboons. The response to native material administered intravenously (i.v.)...Full Text Available

1975-12-01

86

Naturally occurring double-stranded RNA and immune responses. Effects on plaque-forming cells and antibody formation.  

UK PubMed Central (United Kingdom)

A highly purified preparation of double-stranded RNA, obtained from virus-like particles in Penicillium cultures, was found to affert humoral immune responses in mice differentially depending on its...Full Text Available

1975-03-01

87

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

88

A second origin of DNA plus-strand synthesis is required for optimal human immunodeficiency virus replication.  

UK PubMed Central (United Kingdom)

We recently reported that human immunodeficiency virus type 1 (HIV-1) unintegrated linear DNA displays a discontinuity in its plus strand, precisely defined by a second copy of the polypurine tract...Full Text Available

1992-05-01

89

A model for the single stranded random coil form of polydeoxyadenylic acid from minimum energy conformations of the dimeric subunit.  

UK PubMed Central (United Kingdom)

The minimum energy conformations of dApdA have been examined for their suitability as buildings blocks of the single stranded coil form of polynucleotides. Calculations of the characteristic ratio C...Full Text Available

1978-09-01

90

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have ...

2009-09-14

91

Low-cost FPSO for service in the Zaafarana oil field  

Energy Technology Data Exchange (ETDEWEB)

The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced estimate, combined ...

1997-04-01

92

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being especially outstanding. ...

93

The condition monitoring of fluid-filled taped cables employed in underground transmission through dissolved gas analysis  

Energy Technology Data Exchange (ETDEWEB)

There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal ...

1994-12-31

94

Life estimation of high-voltage electric cable. Koden prime atsu cable no jumyo yosoku  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of life estimation of CV cable and OF cable which are generally used as high-voltage power cable. CV cable uses XLPE (crosslined polyethylene) and OF cable uses oil-immersed paper as electrical insulators. Relating to CV cable, voltage deterioration due to partial discharge and electric treeing occurs in a high electric field, and by extrapolating the data of up to the actually used electric field in this high electric field, the life is estimate (there is an n-power deterioration law which is V{sup n} = t between breakdown voltage V and electric applied time t). Validity of this extrapolation, however, is a future issue. Further, in the use under the immersion condition, water tree deterioration phenomena influenced by water content and the electric field which are characteristic of CV cable are seen even in the ...

1991-12-15

96

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, ...

2005-06-15

97

XLPE cables move in on underground transmission  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in cross-linked polyethylene cables mean they can be used at higher voltages and are starting to replace some oil-filled cables. Their good thermal and electrical properties, easy installation and minimal maintenance have helped their growth. A group at Sumitomo Electric Industries Ltd., Japan is studying the performance of these cables. (author).

1986-02-01

99

Fuel wood yarder  

Energy Technology Data Exchange (ETDEWEB)

A small cable yarding system for accumulations of slash on forested land and overstocked non-productive stands is described.

1984-01-01

102

Cable lines for 500 kV  

Energy Technology Data Exchange (ETDEWEB)

Application, design, and installation of the cable line in steel pipe with oil under pressure for 500 kV is considered. The cable construction and design specifications are presented. Manpower requirements for the installation of the cable, extending from the hydrogenerators to the outdoor switchgears or to the change point where they are connected to overhead power lines, are discussed and data provided.

1980-08-01

104

Monitoring oil pressure in h. v. cables  

Energy Technology Data Exchange (ETDEWEB)

The paper-insulated low-pressure oil-filled cable invented in 1917 has been used throughout the world as the major cable system for voltages from 33kV to 525kV and experimentally to 1100kV. The proven reliability of the design is amply demonstrated by the cables installed in the early 1930s still currently in service. The inherent design of an oil-filled cable requires that the low viscosity oil is retained within a lead or aluminium sheath. Changes in oil volume due to changes in ambient temperature and load are accommodated by oil reservoirs which maintain the cable oil pressure within design limits. A microprocessor monitoring system that allows early detection and quick location of oil leaks from high voltage oil-filled cables is described.

1985-03-01

105

High voltage cable in municipal electricity supply  

Energy Technology Data Exchange (ETDEWEB)

The author explains current developments in high voltage cable technology and subsequently describes problems inherent in its application, from the users viewpoint, in municipal electricity supply. The planning of a high voltage cable network and the selection of a specific type of cable are not only dependent on the typical properties of various cables but to a major degree also on the feasible laying technique, the power transmitted, the costs, the stellation treatment of the high voltage network, the acceptance requirement, the inductive influence from telecommunication cable, thermal influences from the environment, eventual safeguards from mechanical and chemical damage to the network, frequency of failure and surveillance and breakdown location. In conclusion, the author portrays potential developments in the fields of high and maximum voltage cable from ...

1980-12-22

106

Analysis on Fault for the Underground Cable Systems at Home  

Energy Technology Data Exchange (ETDEWEB)

Many power apparatus and underground cable systems have been constructed since 1970 in korea. Recently, as the needs for underground T and D systems increase rapidly, any fault on the systems causes enormous economic losses in our society. Thus, this paper described. (1) Survey on the amount and the increasing rates of the underground cable systems at home and abroad. (2) Survey on fault data for the underground cables and joints at home and abroad.From the analysis on fault data, we analyzed the cause of fault and classified the typical fault mode for the underground cable systems. (author). 5 refs., 3 figs., 11 tabs.

1999-05-01

107

Design, manufacturing, installation, protection of 345 kV 750 MVA submarine power cables in New York  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the criteria used for the thermal, electrical, mechanical, hydraulical design of the submarine power cables crossing Long Island Sound to feed New York City. The cables are of the self contained fluid filled (SCFF) type. There is also a description of the special measures adopted to face the exceptionally aggressive environment, due to presence of hydrogen sulphide and of stray currents (caused by electric railways and pipes cathodic protection). The most significant example of such measures is a third sacrificial armour. Four single-core SCFF cables (one spare) were manufactured in Arco Felice (near Naples, Italy), for the New York Power Authority. The average length of the cables is 13 km, jontless. The Italian cable ship 'Giulio Verne', managed by Pirelli, was utilized for the transportation and laying. The ship is equipped with a turntable ...

1992-04-01

108

Oil-filled electric cable with alternate layers of plastic and paper tape  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an oil-filled electric cable and a manufacturing method for said cable, in which the solid insulation is formed, at least in part, by separately applied, alternate layers of cellulose paper tape and of film tapes made of plastic. Prior to application of the tapes around the cable conductor, the moisture content of the paper tape is selected and the swelling of the plastic tape by the oil after application is adjusted, if necessary, such as by immersing the plastic tape in the oil prior to application, so that the swelling of the plastic tape by the oil in the formed cable is offset by the shrinkage of the paper tape during drying of the cable. Also, an apparatus for pre-swelling the plastic tape is described. 4 figs.

1988-01-12

109

External gas pressure oil filled cable; Gasaussendruck-Oelkabel  

Energy Technology Data Exchange (ETDEWEB)

Only two types of 110-kV-cables: Namely XLPE-Cables and External-Gas-Pressure-Cables will be reinstalled in the Federal Republic of Germany. XLPE-Cables have been already developed for higher voltages. An idea how the external-gas-pressure-cable could be made fit for higher voltage levels will be given in this paper. (orig.) [Deutsch] In der Bundesrepublik Deutschland werden in der Zukunft nur noch zwei Kabeltypen der 110-kV-Ebene den Kabelmarkt beherrschen, naemlich: VPE-Kabel und Gasaussendruck-Kabel. Waehrend VPE-Kabel auch fuer hoehere Spannungsebenen bereits entwickelt worden sind, wird im folgenden vorgeschlagen, wie auch das Prinzip der Gasaussendruck-Kabel zu hoeheren Spannungen hin erweitert werden kann. (orig.)

1997-06-02

110

Electrohydrodynamic pumping in cable pipes. Final report  

Energy Technology Data Exchange (ETDEWEB)

Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in ...

1983-02-01

111

Computerized pressure monitoring and control of Hydro-Quebec`s fluid-filled high-voltage underground cable network in Montreal  

Energy Technology Data Exchange (ETDEWEB)

The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management ...

1996-08-01

112

The influence of the explosion of the conductor of an electric cable on the dielectric properties of the polymer insulator  

British Library Electronic Table of Contents (United Kingdom)

The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.

2010-01-01

113

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

114

From 33kV to 132kV cables: Norweb rises to the task  

Energy Technology Data Exchange (ETDEWEB)

Responsibility for the operation and maintenance of the bulk of the 132 kV cable network in England and Wales was transferred from the CEGB to the area boards in the 1970s. Norweb has successfully dealt with the increase in work using in-house expertise exclusively.

1982-09-17

115

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit ...

1981-05-01

116

Gene repression by minimal lac loops in vivo  

UK PubMed Central (United Kingdom)

The inflexibility of double-stranded DNA with respect to bending and twisting is well established in vitro. Understanding apparent DNA physical properties in vivo is...Full Text Available

2010-12-01

117

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

118

HVDC cable design logic for digital computers  

Energy Technology Data Exchange (ETDEWEB)

The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.

1992-10-01

119

HPOF transmission-system economic-evaluation program. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.

1983-01-01

120

Ampacity calculations for mixed underground cable systems in the same ductbank  

Energy Technology Data Exchange (ETDEWEB)

The steady state ampacity is calculated for mixed electric power underground cable circuits in a single trench or ductbank. The methodology presented in this paper can be applied to any practical number of balanced, three phase circuits (each in trefoil, pipe or conduit) of different voltage classes, cable sizes, load currents and cable systems to located anywhere within a single trench or ductbank. The different thermal resistivities of the backfill or ductbank and the surrounding soil are taken into consideration. A practical example for 10 circuits in a trench is provided.

1994-12-31

121

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

122

Transient sheath overvoltages in armored power cables  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.

1996-07-01

123

New type of high voltage sea cable for floating installations; Ny type hoeyspent sjoekabel for flytende installasjoner  

Energy Technology Data Exchange (ETDEWEB)

Nexans has developed a new type of high voltage sea cable with metal barrier for dynamic application, suited for floating installations such as vessels, floating wind turbines or floating platforms. A brief presentation of the cable's design (ml)

2007-07-01

124

Marine cables for high power; Sjoekabel med hoeyere effekt  

Energy Technology Data Exchange (ETDEWEB)

A new type of impregnation jelly can be used instead of traditional oil may reduce the formation of cavities in marine high-voltage direct current cables. This provides a foundation for the development of cables with improved insulation and for higher power. This was a conclusion of the Norwegian ''EFFEKT''-project. Using the jelly reduces the size of the cavities substantially and no discharges seem to occur during formation, growth and collapse of cavities. It is also environmentally friendly, since there is no leakage of oil.

2001-07-01

125

HVDC power cable crossing Kii channel. Advanced technology to lay the submarine cable in two days; Kii suido wo yokogiru denryoku cable. Kaitei fusetsu wo futsuka de konasu shin`ei sochi  

Energy Technology Data Exchange (ETDEWEB)

Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning ...

1998-07-01

126

Fully synthetic taped insulation cables  

Energy Technology Data Exchange (ETDEWEB)

A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

1984-12-11

127

French power for Jersey goes under water  

Energy Technology Data Exchange (ETDEWEB)

A proposed project by which the island of Jersy could buy electric power from France is discussed. The interconnector will be capable of transmitting up to 50MW. Included in the project will be 27 km of submarine cable and 23 km of underground cable. An oil-filled cable containing 120 mm diameter copper conductors and weighing 47 kg/m is used. Details of the installation and oil system are given.

1983-01-21

128

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

129

Calculation of the thermal load of a high voltage cable with forced circulation of oil with the help of modeling on an analog computer  

Energy Technology Data Exchange (ETDEWEB)

Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.

1980-01-01

130

Calculating ac/dc resistance ratios for high-pressure oil-filled cable designs. Volume 2. Details of mathematical derivations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.

1985-04-01

131

Test results of TQS03: a LARP shell-based Nb3Sn quadrupole using 108/127 conductor  

Energy Technology Data Exchange (ETDEWEB)

Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an increased fraction of copper and a lower Jc were ...

2009-09-13

132

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer circumferential wall thinning ...

1979-01-01

133

Proposal for a commercial interconnection among the Hawaiian islands based on the results of the Hawaii deep water cable program  

Energy Technology Data Exchange (ETDEWEB)

After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.

1992-10-01

134

Elimination of L-A double-stranded RNA virus of Saccharomyces cerevisiae by expression of gag and gag-pol from an L-A cDNA clone.  

UK PubMed Central (United Kingdom)

We report that expression of a nearly full-length cDNA clone of the L-A double-stranded RNA virus causes virus loss in a wild-type strain of Saccharomyces cerevisiae. We show that in this system exclusion...Full Text Available

1993-05-01

135

Characterization and engineering of sequences controlling in vivo synthesis of brome mosaic virus subgenomic RNA.  

UK PubMed Central (United Kingdom)

Expression of brome mosaic virus (BMV) coat protein and internal genes of many other positive-strand RNA viruses requires initiation of subgenomic mRNA synthesis from specific internal sites on minus-strand...Full Text Available

1988-07-01

136

A single-stranded gap in human immunodeficiency virus unintegrated linear DNA defined by a central copy of the polypurine tract.  

UK PubMed Central (United Kingdom)

The structure of unintegrated human immunodeficiency virus type 1 (HIV-1) DNA from acutely infected human lymphoid cells was analyzed by nuclease S1 cleavage. We observed a unique, discrete single-stranded...Full Text Available

1991-05-01

137

Honshu-Shikoku linking transmission cable building plan. ; Development of power sources. Honshi renkei sodensen kensetsu keikaku. ; Dengen kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground ...

1992-03-01

138

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers ...

1981-05-01

139

Cable-to-air terminations: The cable system's second weakest link  

Energy Technology Data Exchange (ETDEWEB)

Transmission terminations available today are very reliable, but they need to be. In the field, they are continually exposed to pollution and extremes of ambient temperature. In many cases, they are in the rifle sights of vandals. In contrast, cable joints - often cited as the weakest links from an electrical viewpoint - are generally protected from physical damage underground and many of the short cable systems being installed in the US today can be built without joints. All cable systems need terminations - mostly to air-insulated equipment. At 69 through 138 kV, there is intense competition among manufacturers to supply terminations for solid-dielectric cable that are low in cost, reliable, and require a minimum of skill to install. Some utilities are looking also for terminations that fit a range of cable sizes; terminations that do not contain liquid that can leak out; and ...

1994-12-01

140

HVDC submarine power cables systems state of the art and future developments  

Energy Technology Data Exchange (ETDEWEB)

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, ...

1995-12-31

141

Study for developing method of repairing interior of duct. Kanro naimen hoshu koho no kaihatsu kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, water cut-off performance, chemical resistance, and shape retention performance against ...

1991-03-25

142

Integration of turbo-generator modules in digital transient network analyzer  

Science.gov (United States)

The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: (a) the theoretical ...

1994-05-01

143

DYMAC communications system  

Energy Technology Data Exchange (ETDEWEB)

The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system components are commercially available; some have been modified at LASL for DYMAC purposes; others were designed and fabricated at LASL. This manual provides circuit diagrams ...

1980-01-01

144

Unique approach to an old problem: New technology helps BC Hydro locate heat resistance  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the ...

1997-06-01

145

Repair of failed 138kV pipe type cable line  

Energy Technology Data Exchange (ETDEWEB)

On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short length of ...

1996-11-01

146

Calculation of the transmission capacity of long-distance EHV single-core submarine cable systems  

Energy Technology Data Exchange (ETDEWEB)

A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the transmission capacities ...

1981-11-01

147

Application of the CFAST zone model to the Fire PSA  

Energy Technology Data Exchange (ETDEWEB)

The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the cable integrity. According to the analysis results, the integrity of the ...

2010-10-15

148

Ultrafast fluorescence dynamics of Sybr Green I/DNA complexes  

British Library Electronic Table of Contents (United Kingdom)

The ultrafast dynamics of the DNA fluorescent dye Sybr Green I (SG) has been studied in buffer, single-stranded (ssDNA), double-stranded (dsDNA) and triple-stranded DNA (tsDNA). The fluorescence quantum yield of SG increases dramatically when bound to DNA (including tsDNA). The fluorescence dynamics of the free SG has shown two decay components with 0.15-0.4ps and 1.3-2.1ps time constants, depending on the fluorescence wavelength. Upon binding to DNA, the dynamics becomes slower exhibiting four decay components. This is mainly due to the restriction of the internal motions of the dye caused by the relatively rigid environment of the dye complexed with DNA.

2010-01-01

149

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

150

Axiomatic Design Approach for a Reactor Head Structure Assembly  

Energy Technology Data Exchange (ETDEWEB)

Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.

2006-07-01

151

ch4  

Science.gov (United States)

Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...

152

State of the art in installation of buried HV and EHV cables; Etat de l'art sur la pose des cables souterrains a haute et tres haute tension  

Energy Technology Data Exchange (ETDEWEB)

CIGRE has set up a new working group - Insulated High Voltage Cables - under the auspices of Study Group 21. The working group will examine the various techniques used for the installation of HV and EHV cables and the design parameters to be applied. Twelve installation techniques are known, but only three of these ar used at present. Following an international study carried out by the working group, a clear picture of the state of the art in 1998 has emerged. It has also been possible to identify future trends in the design of buried circuits. (authors)

2000-05-01

153

Large eddy simulation based fire modeling applications for Indian nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. Keeping this in mind the deterministic fire hazard analysis was carried out for the Madras Atomic Power ...

2005-07-01

154

Application of the CFAST zone model to the Fire PSA  

British Library Electronic Table of Contents (United Kingdom)

The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the c...

2010-01-01

155

Two Proline-Rich Nuclear Localization Signals in the Amino- and Carboxyl-Terminal Regions of the Borna Disease Virus Phosphoprotein  

UK PubMed Central (United Kingdom)

Borna disease virus (BDV) uses a unique strategy of replication and transcription which takes place in the nucleus, unlike other known, nonsegmented, negative-stranded RNA viruses of animal origin....Full Text Available

1998-12-01

156

Transcription induces strand-specific mutations at the 5? end of human genes  

UK PubMed Central (United Kingdom)

A regional analysis of nucleotide substitution rates along human genes and their flanking regions allows us to quantify the effect of mutational mechanisms associated with transcription in germ line...Full Text Available

2008-08-01

157

The role of Holliday junction resolvases in the repair of spontaneous and induced DNA damage  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) and other lesions occur frequently during cell growth and in meiosis. These are often repaired by homologous recombination (HR). HR may result in the formation of DNA...Full Text Available

2011-09-01

158

Potential of cattails as an energy source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Research on the feasibility of growing cattails as an energy crop is described. The following topics are included: productivity in natural strands, germination requirements for seed, establishing stands by seeding, rhizome dormancy and development, harvesting and stand establishment, and analysis of canopy structure and radiation profiles in a natural community. (MHR)

1980-01-01

159

Palindromic Sequence Plays a Critical Role in Human Foamy Virus Dimerization  

UK PubMed Central (United Kingdom)

The retroviral RNA genome is dimeric, consisting of two identical strands of RNA linked near their 5′ ends by a dimer linkage structure. Previously it was shown that human foamy virus (HFV)...Full Text Available

2001-04-01

160

Molecular dynamics of a ?B DNA element: base flipping via cross-strand intercalative stacking in a microsecond-scale simulation  

UK PubMed Central (United Kingdom)

The sequence-dependent structural variability and conformational dynamics of DNA play pivotal roles in many biological milieus, such as in the site-specific binding of transcription factors to target...Full Text Available

2008-09-01

161

Mechanisms of chemotherapy-induced human ovarian aging: double strand DNA breaks and microvascular compromise  

UK PubMed Central (United Kingdom)

The mechanism of chemotherapy-induced acceleration of ovarian aging is not fully understood. We used doxorubicin, a widely used cancer chemotherapeutic, in a variety of in vivo xenograft,...Full Text Available

162

J4P Evaluation of Externally Heated Pulsed MPD Thruster Cathodes  

Science.gov (United States)

twenty 350 V, 2.5 mF aluminum electrolytic capacitors with 10.8 mH inductors made of multi-strand wire. The PFN discharge was controlled using an silicon ...

163

Insights into Cdc13 dependent telomere length regulation  

UK PubMed Central (United Kingdom)

Cdc13 is a single stranded telomere binding protein that specifically localizes to the telomere ends of budding yeasts and is essential for cell viability. It caps the ends of chromosomes thus preventing...Full Text Available

164

Identification of a Central DNA Flap in Feline Immunodeficiency Virus  

UK PubMed Central (United Kingdom)

A duplication of the polypurine tract (PPT) at the center of the human immunodeficiency virus type 1 (HIV-1) genome (the cPPT) has been shown to prime a separate plus-strand initiation and to result...Full Text Available

2001-10-01

165

Identification and characterization of plasmids from the western aster yellows mycoplasmalike organism.  

UK PubMed Central (United Kingdom)

Supercoiled double-stranded DNA molecules (plasmids) were isolated from plants infected with three laboratory strains of western aster yellows mycoplasma-like organism (AY-MLO) by using cesium chloride-ethidium...Full Text Available

1990-03-01

166

Capture of genomic DNA on glass microscope slides  

UK PubMed Central (United Kingdom)

It is well known that DNA strands bind to silica surfaces in the presence of high concentrations of chaotropic salts. We developed simple methods to evaluate binding and recovery of DNA on flat...Full Text Available

2007-06-15

167

Analysis of illegitimate genomic integration mediated by zinc-finger nucleases: implications for specificity of targeted gene correction  

UK PubMed Central (United Kingdom)

BackgroundFormation of site specific genomic double strand breaks (DSBs), induced by the expression of a pair of engineered zinc-finger nucleases (ZFNs), dramatically increases the...Full Text Available

168

A Cellular J-Domain Protein Modulates Polyprotein Processing and Cytopathogenicity of a Pestivirus  

UK PubMed Central (United Kingdom)

Pestiviruses are positive-strand RNA viruses closely related to human hepatitis C virus. Gene expression of these viruses occurs via translation of a polyprotein, which is further processed by cellular...Full Text Available

2001-10-01

169

?H2AX and cancer  

UK PubMed Central (United Kingdom)

Histone H2AX phosphorylation on a serine four residues from the carboxyl terminus (producing γH2AX) is a sensitive marker for DNA double-strand breaks (DSBs). DSBs may lead to cancer...Full Text Available

2008-12-01

170

2001 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach of the Columbia River. The evaluation, in the fifth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2001 field season.

171

2000 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the fourth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2000 field season.

172

1999 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River, annual report 1999.; ANNUAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the third year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1999 field season.

173

1998 evaluation of juvenile fall chinook salmon stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the second year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fish species, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1998 field season.

174

Pteromalus puparum venom impairs host cellular immune responses by decreasing expression of its scavenger receptor gene.  

Science.gov (United States)

Insect host/parasitoid interactions are co-evolved systems in which host defenses are balanced by parasitoid mechanisms to disable or hide from host immune effectors. Although there is a rich literature on these systems, parasitoid immune-disabling mechanisms have not been fully elucidated. Here we report on a newly discovered immune-disabling mechanism in the Pieris rapae/Pteromalus puparum host/parasitoid system. Because venom injections and parasitization suppresses host phagocytosis, we turned attention to the P. rapae scavenger receptor (Pr-SR), posing the hypothesis that P. puparum venom suppresses expression of the host Pr-SR gene. To test our hypothesis, we cloned a full-length cDNA of the Pr-SR. Multiple sequences alignment showed the deduced amino acid sequence of Pr-SR is similar to scavenger receptors of other lepidopterans. Bacterial and bead injections induced Pr-SR mRNA and protein expression, which peaked at 4h post-bead injection. Venom injection ...

2011-07-22

175

Getting gas to shore  

Energy Technology Data Exchange (ETDEWEB)

Calls for containers to transport compressed natural gas, and a ship or barge to house some 200 employees in the Terra Nova offshore oilfield while the oil field's floating production, storage and offloading (FPSO) system is undergoing a major overhaul, are attracting attention on Canada's east coast offshore oilpatch. The FPSO is located offshore, 350 km east of St. John's, Newfoundland. Petro-Canada, operators of the FPSO anticipate that by having all required personnel nearby, the total shutdown time for the overhaul could be minimized. The CNG container was designed by Trans Ocean Gas Inc. in response to an invitation by Husky Oil and Petro-Canada, the White Rose field partners. Trans Ocean Gas strongly believes that CNG will become the technology of choice for getting natural gas ashore and to markets from stranded hydrocarbon pools in Atlantic Canada and the rest of the world where pipeline systems would be too expensive to build ...

2004-10-01

176

Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV  

Energy Technology Data Exchange (ETDEWEB)

The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

1994-07-11

177

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

178

Mortality and incidence of cancer among oil exposed workers in a Norwegian cable manufacturing company. Part I. Exposure conditions 1920-79.  

UK PubMed Central (United Kingdom)

Heavy high viscosity oils, transformer oils, and very light low viscosity oils have been used in a Norwegian company in the impregnation, sheathing, and installation of paper insulated cables. The aim...Full Text Available

1988-09-01

179

Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields  

British Library Electronic Table of Contents (United Kingdom)

The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.

2011-01-01

180

Construction - laying and installation techniques for extruded and self contained fluid filled cable systems  

Energy Technology Data Exchange (ETDEWEB)

The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.

2001-07-01

181

Calculation of current-carrying capacity of forced cooled high-voltage cable lines  

Energy Technology Data Exchange (ETDEWEB)

The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current ...

1982-01-01

182

Barrier filter for fluorescence microscopy of strongly autofluorescent plant tissues. Application to actin cables in Chara.  

Science.gov (United States)

A liquid barrier filter for use in fluorescence microscopy of strongly autofluorescent plant tissues is described. The filter consists of a methanol solution of cupric chloride and ferric chloride and isolates fluorescein fluorescence from the strong red autofluorescence of photosynthetic plant tissues. Subcortical actin cables in the giant alga Chara are being visualized through use of this filter together with heavy meromyosin labeling. PMID:90068

1979-05-01

183

10 MWe Solar Thermal Central Receiver Pilot Plant: solar facilities design integration. Plant electrical equipment installation. Construction package No. 11 (RADL Item 7-35)  

Energy Technology Data Exchange (ETDEWEB)

Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.

1980-07-01

184

Using fiber optic sensors to protect intake, outflow, and other environmentally exposed openings  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the protection of opening that are exposed to the environment in nuclear facilities which presents an almost overwhelming engineering challenge. Intakes and outflows must permit the passage of large volumes of air or water without impeding their flow, and they are often exposed to corrosive salt and chemicals. An intrusion detection sensor that is intended to protect these openings must be capable of operating reliably under environmentally harsh conditions, and at the same time either provide a physical delay barrier or attach to an existing barrier. A new fiber optic sensor technology has now been developed specifically for protecting environmentally exposed openings. This sensor uses a fiber optic cable embedded in a neoprene rubber frame which is reinforced with Kevlar threads or braided steel cable. The sensor is configured in a mesh pattern with openings sufficiently large to permit air or water to flow unimpeded, ...

1991-01-01

185

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is necessary to prepare ...

1988-02-10

186

New technique: recovery of cables without trenching works; Verfahren zur grabungsfreien Bergung von Kabeln  

Energy Technology Data Exchange (ETDEWEB)

Flow Tex and ABB Energiekabel GmbH have developed a technique which allows the recovery of cables without requiring any trenching works. The new technique was successfully used for the first time for a pilot project in 1995. The authors report on two recent recovery projects (1998) in which an optimised technology was used for recovering a total of 1 500 m system length of 110 kV low-pressure oil-filled cables in Stuttgart and Munich on very different conditions. The authors describe the operational experiences with the cable connections and highlight the background stipulating the removal of the cables. (orig.) [Deutsch] Ein Verfahren zur grabungsfreien Bergung von Kabeln, gemeinsam entwickelt von FlowTex und ABB Energiekabel, wurde erstmals in einem Pilotprojekt 1995 mit Erfolg eingesetzt. Die Verfasser berichten ueber zwei Bergungsprojekte, bei denen 1998 mit der optimierten Technik in Stuttgart und ...

1999-03-22

187

500 kV oil-filled cable installed on bridges  

Energy Technology Data Exchange (ETDEWEB)

The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmission line was proposed. The most significant feature of this transmission line is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting transmission line and also presents some technical features concerning 500 kV cables.

1990-04-01

188

Renovation of Isogo thermal power plant of Electric Power Development Co. with new and old systems near to each other; Dengen Kaihatsu (kabu) Isogo karyoku hatsudensho koshin koji shinsetsu hosui kanro to kisetsu hatsudensho OF cable no kinsetsu seko  

Energy Technology Data Exchange (ETDEWEB)

This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend ...

1998-09-05

189

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

190

Environmental aspects concerning medium- and highvoltage cables; Umweltfragen bei Mittel- und Hochspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

Environmental compatibility is nowadays a very important part in the case of planing, construction, operation and maintainance of cable systems. A lot of laws and orders have to be observed. Some new aspects concerning the removal of oil filled cables and the consideration of electromagnetic fields even for cabels will be presented. (orig.) [Deutsch] Der Umweltschutz ist heute unverzichtbarer Bestandteil der Planung, Bau, Betrieb und Instandhaltung von Kabelanlagen. Zahlreiche Gesetze und Verordnungen sind hierbei zu beachten. Der Verfasser stellt einige Neuerungen im Zusammenhang mit dem Ausbau und Oelkabeln vor und erlaeutert die auch bei Kabeln zu beruecksichtigenden elektromagnetischen Felder. (orig.)

1997-09-22

191

Development of flexible joint for 500kV Al-sheathed O. F. cable  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a flexible dimensionaly flush joint for 500kV aluminum-sheathed oil-filled cables capable of being assembled, pulled an installed in a similar manner to cables at site which has been developed. This joint is intended for use at intermediate points on long bridges or tunnels where local assembly and installation of conventional joints would be difficult. In developing the joint various novel and original techniques have been employed, including the flexible flush jointing of segmental conductors, the flexible jointing of paper insulation by a combination of wrapping-back and stepping methods, plus on-site aluminum sheath corrugating and sealing methods.

1992-10-01

192

Building connections - Transition from TN-C to TN-S five-core building connection cable solves problems; Hausanschluss: Wechsel von TN-C auf TN-S  

Energy Technology Data Exchange (ETDEWEB)

This article discusses the use of five-core cables to provide utility customers with the best possible prerequisites for trouble-free operation of electrical installations and equipment. The TN-S system in buildings and the new TN-S-five-core house-connection cable for connections between the mains distribution point and buildings is introduced. The long-term target of providing TN-S-systems in power distribution even as far as the local transformer is also discussed. The advantages of the system are discussed and various configurations for different types of supply are described.

2005-07-01

193

The mitochondrial genome of the entomophagous endoparasite Xenosvesparum (Insecta: Strepsiptera)  

Energy Technology Data Exchange (ETDEWEB)

In this study, the nearly complete sequence (14,519 bp) of the mitochondrial DNA (mtDNA) of the entomophagous endoparasite Xenos vesparum (Insecta: Strepsiptera) is described. All protein coding genes (PCGs) are in the arrangement known to be ancestral for insects, but three tRNA genes (trnA, trnS(gcu), and trnL(uag)) have transposed to derived positions and there are three tandem copies of trnH, each of which is potentially functional. All of these rearrangements except for that of trnL(uag) is within the short span between nad3 and nad4 and there are numerous blocks of unassignable sequence in this region, perhaps as remnants of larger scale predisposing rearrangements. X. vesparum mtDNA nucleotide composition is strongly biased toward As and Ts, as is typical for insect mtDNAs. There is also significant strand skew in the distribution of these nucleotides, with the J-strand being richer in A than T and in C than G, and the ...

2005-12-01

194

Underground cable: Best for cogeneration links  

Energy Technology Data Exchange (ETDEWEB)

This article addresses the connection of cogeneration plants to the utility system. The article provides examples for use in illustrating the problems that must be overcome and the solution chosen. These illustrations include high voltage utility connection, multiple connections to the utility at one location, and dealing with losses and obstructions.

1989-05-01

195

How to charge electric-powered automobiles; Volle Ladung, aber wie?  

Energy Technology Data Exchange (ETDEWEB)

Electric cars can be recharged via charging stations, battery exchange, or induction cable lanes in asphalted roads. The users' wishes remain unexplored, so a number of technologies are competing in this sector.

2011-01-15

196

Estimating production rates and operating costs of timber harvesting equipment in the northern Rockies. General technical report  

Energy Technology Data Exchange (ETDEWEB)

The report summarizes studies of ground, cable, and aerial logging systems in the Northern Rockies over a 15-year period. It provides nomographs and tables for calculating productivity and a system for comparing energy requirements.

1982-09-01

197

Criminal Prohibitions on the Publication of Classified Defense Information. Updated December 6, 2010.  

Science.gov (United States)

The recent online publication of classified defense documents and diplomatic cables by the organization WikiLeaks and subsequent reporting by the New York Times and other news media have focused attention on whether such publication violates U.S. criminal...

2010-01-01

198

3 phase-3 wire 10kW interconnected inverter for photovoltaic power generation; Sanso sansen 10kW taiyoko hatsuden`yo keito renkei inverter  

Energy Technology Data Exchange (ETDEWEB)

Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by 3V, and measures the power level at each point. Comparison is then made between the values measured at the said points on a PV profile, and the operating voltage value is ...

1997-10-30

199

Transient suppression of MLH1 allows effective single-nucleotide substitution by single-stranded DNA oligonucleotides  

British Library Electronic Table of Contents (United Kingdom)

Short synthetic single-stranded oligodeoxyribonucleotides (ssODNs) can be used to introduce subtle modifications into the genome of mouse embryonic stem cells (ESCs). We have previously shown that effective application of ssODN-mediated gene targeting in ESC requires (transient) suppression of DNA mismatch repair (MMR). However, whereas transient down-regulation of the mismatch recognition protein MSH2 allowed substitution of 3 or 4 nucleotides, 1 or 2 nucleotide substitutions were still suppressed. We now demonstrate that single- or dinucleotide substitution can effectively be achieved by transient down-regulation of the downstream MMR protein MLH1. By exploiting highly specific real-time PCR, we demonstrate the feasibility of substituting a single basepair in a non-selectable gene. Howev...

2011-01-01

200

Superconductors with 2.5 micron NbTi filaments  

International Nuclear Information System (INIS)

Multifilamentary superconductors with 2.5 micron sized NbTi filaments are being proposed for the High Energy Booster part of the SSC project. The small filament size and the large number of filaments in the superconductor strands make the fabrication a challenge, especially in view of the high critical current performance required of them. IGC has produced two 309 mm diameter prototype billets and fabricated both the 'Inner' and the 'Outer' grade strands. The production approach was based on a triple extrusion process incorporating Cu-0.6 st.% Mn as the interfilament matrix material. The results of this pilot development effort, in terms of critical current density and mechanical properties, are presented in this paper. Appropriate comparisons with past performances are made.

1991-03-13

201

GTL or LNG: which is the best way to monetize ?stranded?? natural gas?  

British Library Electronic Table of Contents (United Kingdom)

A large portion of world?s natural gas reserves are ?stranded?? resources, the drive to monetize these resources leads to the development of gas-to-liquids (GTL) and liquefied natural gas (LNG) technologies. LNG has the advantage of having been developed for the past 40 years and having an excellent safety record. GTL on the other hand is another option with substantial benefits, but its development stage and commercial viability are far behind LNG. This paper presents a techno-economic comparison of GTL with LNG, including technical development, plant efficiency, market potential for the products, and capital cost for the infrastructure. The aim is to give an overall view on both LNG and GTL and provide a perspective on the profitability of these two technologies.

2008-01-01

202

Effect of Diaporthe RNA virus 1 (DRV1) on growth and pathogenicity of different Diaporthe species  

British Library Electronic Table of Contents (United Kingdom)

A 4.1?kbp positive-strand RNA virus known as Diaporthe RNA virus 1 (DRV1) occurs in hypovirulent, non-sporulating isolates of the fungal pathogen Diaporthe perjuncta. A full-length cDNA clone of DRV1 was developed and RNA transcribed from the cDNA clone used to transfect different Diaporthe spp. The transfected species included three D. ambigua isolates and an unidentified Phomopsis asexual state of a Diaporthe sp. Successful transfections were confirmed using RT-PCR. Although the in vitro-transcribed positive sense single-stranded RNA used for transfection included vector sequences at both ends, the genomes of progeny virus from DRV1-transfected isolates were free of the vector sequences. Transfection resulted in morphological changes in these fungal pathogens. However, the presence of DR...

2011-01-01

203

Identification and characterization of noncoding small RNAs in Streptococcus pneumoniae serotype 2 strain D39.  

Science.gov (United States)

We report a search for small RNAs (sRNAs) in the low-GC, gram-positive human pathogen Streptococcus pneumoniae. Based on bioinformatic analyses by Livny et al. (J. Livny, A. Brencic, S. Lory, and M. K. Waldor, Nucleic Acids Res. 34:3484-3493, 2006), we tested 40 candidates by Northern blotting and confirmed the expression of nine new and one previously reported (CcnA) sRNAs in strain D39. CcnA is one of five redundant sRNAs reported by Halfmann et al. (A. Halfmann, M. Kovacs, R. Hakenbeck, and R. Bruckner, Mol. Microbiol. 66:110-126, 2007) that are positively controlled by the CiaR response regulator. We characterized 3 of these 14 sRNAs: Spd-sr17 (144 nucleotides [nt]; decreased in stationary phase), Spd-sr37 (80 nt; strongly expressed in all growth phases), and CcnA (93 nt; induced by competence stimulatory peptide). Spd-sr17 and CcnA likely fold into structures containing single-stranded regions between hairpin structures, whereas Spd-sr37 ...

2010-01-01

204

Submarine 525 kV power transmission line for Vancouver island  

Energy Technology Data Exchange (ETDEWEB)

The studies undertaken by the B.C. Hydro company at the Canada showed that the existing system of hydroelectric power plants and transport cables will not be able to satisfy the increasing energy demand on the Vancouver island after 1985, and that the best solution will be the installation of a 525 kV transfer system from the continent. THe STK participated to the development and the immersion of this new system, the first in the world comprising submarine 525 kV transport parts. This paper presents the planning, the development, the submerging and the installation of two sections of submarine cable.

1985-01-01

205

Lessons from Auckland  

Energy Technology Data Exchange (ETDEWEB)

The major distributor and retailer of electrical power to Auckland, New Zealand, is Mercury Energy Limited. Following the sequential failure of the four 110kV underground cables, two gas-filled and two oil-filled, which supply the central business district, power was interrupted for 29 days from the 20th February 1998. A government inquiry was instituted, to examine what happened, why, and what lessons could be drawn for the future. Inadequacies in Mercury Energy`s cable maintenance and operating procedures were identified. The findings of the inquiry and its recommendations are reported. (UK)

1998-08-01

206

Electric power cable  

Energy Technology Data Exchange (ETDEWEB)

An oil-immersion electrically insulated cable of high performance is constructed by wrapping a conductor with an insulating layer formed by winding on the conductor polypropylene film, and impregnating the insulating layer with an insulating oil preferably dodecyl benzene. The polypropylene film has a density in the range of 0.905 to 0.915 g/cm/sup 3/, birefringence in the range of 0.020 to 0.035, ratio of strengths in two axial directions (tensile strength in the longitudinal direction/tensile strength in the lateral direction) in the range of 5 to 15, and thickness in the range of 70 to 300 microns.

1987-08-14

207

Computer modeling of electrical performance of detonators  

Energy Technology Data Exchange (ETDEWEB)

An empirical model of detonator electrical performance which describes the resistance of the exploding bridgewire (EBW) or exploding foil initiator (EFI or slapper) as a function of energy, deposition will be described. This model features many parameters that can be adjusted to obtain a close fit to experimental data. This has been demonstrated using recent experimental data taken with the cable discharge system located at Sandia National Laboratories. This paper will be a continuation of the paper entitled ``Cable Discharge System for Fundamental Detonator Studies`` presented at the 2nd NASA/DOD/DOE Pyrotechnic Workshop.

1995-05-01

208

A Insulating Design of SF{sub 6} GAS Sealing end of Condenser Cone Type Used for 345 kV OF Cable  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we describes the research in condenser cone of SF{sub 6} gas sealing end for 345 kV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory and FEM. As a results, we have been designed the condenser cone and the inner insulation part of SF{sub 6} sealing end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone. (author). 4 refs., 3 figs., 3 tabs.

1994-07-01

209

500-kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.

1980-01-01

210

The electrical measurement of AC losses in a three-phase tri-axial superconducting cable  

International Nuclear Information System (INIS)

In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase measurements with only one transport current ...

2010-09-01

211

Primary organization of nucleosomal core particles is invariable in repressed and active nuclei from animal, plant and yeast cells.  

UK PubMed Central (United Kingdom)

A refined map for the linear arrangement of histones along DNA in nucleosomal core particles has been determined by DNA-protein crosslinking. On one strand of 145-bp core DNA, histones are aligned in...Full Text Available

1985-05-24

212

Plasmids for the cloning and expression of full-length double-stranded cDNAs under control of the SV40 early or late gene promoter.  

UK PubMed Central (United Kingdom)

Okayama and Berg (1) have recently described a technique for the high efficiency cloning of full-length dscDNAs. We have constructed eukaryotic expression vectors compatible both with this technique...Full Text Available

1983-10-25

213

How can the EU respond to Kazakhstan'  

Wastenet

... The final strand is to invest in new infrastructure, supporting the growth of small and medium-sized businesses and developing new productive industries like pharmaceuticals, locomotive engineering and plastics. Having acted as an adviser to the government, I can see several reasons why the EU should welcome and support this model of economic development. The most important is that Kazakhstan's diversification and its determination to move production up the ...

214

Equine infectious anemia virus and human immunodeficiency virus DNA synthesis in vitro: characterization of the endogenous reverse transcriptase reaction.  

UK PubMed Central (United Kingdom)

The endogenous reverse transcriptase reaction of equine infectious anemia virus (EIAV) has been studied, and conditions allowing synthesis of full-length minus-strand DNA have been determined. In contrast...Full Text Available

1991-04-01

215

Dissecting toxin immunity in virus-infected killer yeast uncovers an intrinsic strategy of self-protection  

UK PubMed Central (United Kingdom)

Toxin-secreting “killer” yeasts were initially identified >40 years ago in Saccharomyces cerevisiae strains infected with a double-stranded RNA “killer”...Full Text Available

2006-03-07

216

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the FPSO, this problem was complex. Understanding that, due to the Joule Thompson ...

2008-07-01

217

White oils for high voltage cables  

Energy Technology Data Exchange (ETDEWEB)

''S-220'' white oil is used currently to impregnate and fill high voltage cables for 110-500 kilovolts; it has high electrical characteristics and meets production and use standards. High pressure and cooling problems, however, require filling cables with lower viscosity oils, while insulation needs still demand high viscosity. The authors developed a new white oil similar to S-220 using a neutral oil made in producing sulfonate additives. The process involved vacuum distillation, low-temperature paraffination, sulfation with oleum, neutralizing with ammonium hydroxide and simultaneous extraction of sulfo-salts and contact purification. The lowest content of aromatic hydrocarbons was sought. Dielectric qualities varied with viscosity. Satisfactory thermooxidational capability was found at 50/sup 0/C with an oil of no less than 50 mm/sup 2//sec viscosity. The final white oil had no more than 2% aromatic ...

1982-10-01

218

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...

2008-10-01

219

Short circuit strength of surface mounted 110 kV cables; Kurzschlussverhalten von 110-kV-Kabeln in offener Legung  

Energy Technology Data Exchange (ETDEWEB)

The danger potential for 110 kV cables, which are installed on racks and in tunnels, caused by catching fire because of arcing short circuits and mechanical overstressing by peak shortcircuit current, has been experimental analysed under Bewag network conditions. As a result, recommendations for an improved installation of 110 kV cables are given. (orig.) [Deutsch] Fuer offen gelegte 110-kV-Kabel in Raeumen, auf Fussboeden und in Schaechten wurde das von Kurzschluessen auf den Kabeln ausgehende Gefaehrdungspotential fuer die Entstehung von Kabelbraenden durch Fehlerlichtboegen und fuer eine mechanische Ueberbeanspruchung von Kabeln durch Stosskurzschlussstroeme unter Beruecksichtigung der Netzverhaeltnisse der Bewag experimentell untersucht. Im Ergebnis geben die Verfasser Empfehlungen fuer die sichere Anordnung offen gelegter 110-kV-Kabel. (orig.)

1998-03-23

220

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use ...

1982-10-01

221

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube when the latter is raised to the surface is assured by threading the cord through plastic tubing mounted to the wall of the ...

1983-04-26

222

Light weight underground pipe or cable installing device  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

1985-01-08

223

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

2006-01-03

224

Design of Reactor Head Structure Assembly Using Axiomatic Design  

Energy Technology Data Exchange (ETDEWEB)

The Reactor Head Structure Assembly(RHSA) is the structure located on the reactor assembly. The purpose of the assembly is providing interface location for cables, preventing pipe whips, prohibiting instruments from becoming missiles, and restraining CEDMs' horizontal motion. On the RHSA, Reactor Disconnect Panels(RDP) are installed. The installation location of RDP is to be decided to minimize the geometric interface with other components. Since the neighborhood of RHSA is crowded due to many connectors and cables, it is necessary to find the good design of RHSA to make an intricate situation attenuated and the required function maintained. The geometric shape and overall configuration of RHSA are determined by axiomatic design approach. The FRs of RHSA are specified and the corresponding DPs are found to satisfy FRs in sequence. The finite element analysis is carried out based on the result of the axiomatic design to evaluate the ...

2007-07-01

225

Successful test of FDDI  

CERN Multimedia

Successful test of FDDI

1990-01-01

226

The complete mitochondrial genome of Atelura formicaria (Hexapoda: Zygentoma) and the phylogenetic relationships of basal insects.  

Science.gov (United States)

In this study, the complete sequence of the mitochondrial DNA (mtDNA) of Atelura formicaria (Hexapoda: Zygentoma) is described. The molecule is 15.205 bp in length and it is the third complete mt genome sequenced from the Zygentoma. The genome organization conforms with the putative ancestral insect gene arrangement. All protein coding genes use standard initiation codons (methionine and isoleucine). The exception is nad4 that starts with GTG, a codon used for this purpose in other insect species. A peculiar strand skew bias is observed, given that the PCGs encoded on the J-strand contain more thymines than adenines and more cytosines than guanines. This trend in nucleotide composition has been observed also in the "firebrat" Thermobia domestica (Zygentoma, Lepismatidae), but differs from that of the majority of hexapod species, including Tricholepidion gertschi (Zygentoma, Lepidotrichidae), where adenines and cytosines outnumber thymines and ...

2009-03-11

227

Organisms posses enzymes that function in the repair of DNA damaged by radiations, chemicals and metabolic events  

International Nuclear Information System (INIS)

This report briefly describes the studies on the mechanism of in vivo DNA repairing by the author in Research Reactor Institute, Kyoto Univ. for the past 30 years. First, the ability of UV radiation to induce transformation was investigated with viral DNA. The formation of thymine-thymine dimer was found harmful to organisms and such dimers were removable by UV-radiation at a low frequency. The mutability was determined in three different E.coli strains with mutator gene, mutT, mutS or mutL. The ability to excise 8-oxoguanin developed in primer DNA was deficient in mutT and miss-pairing left after DNA replication could not be recovered in mutL and mutS strains. Further, DNA repairing mechanism was investigated in other microorganisms; single-strand cleavage caused by exposure to BNCB radiation (boron-neutron-captured beam) could not be repaired in E. coli. Whereas for Deinococcus radiodurans, of which survival rate was not decreased by #gamma#-ray radiation at 5 ...

1998-01-01

228

Cotton plants expressing CYP6AE14 double-stranded RNA show enhanced resistance to bollworms  

British Library Electronic Table of Contents (United Kingdom)

RNA interference (RNAi) plays an important role in regulating gene expression in eukaryotes. Previously, we generated Arabidopsis and tobacco plants expressing double-stranded RNA (dsRNA) targeting a cotton bollworm (Helicoverpa armigera) P450 gene, CYP6AE14. Bollworms fed on transgenic dsCYP6AE14 plants showed suppressed CYP6AE14 expression and reduced growth on gossypol-containing diet (Mao et?al., in Nat Biotechnol 25: 1307?1313, 2007). Here we report generation and analysis of dsRNA-expressing cotton (Gossypium hirsutum) plants. Bollworm larvae reared on T2 plants of the ds6-3 line exhibited drastically retarded growth, and the transgenic plants were less damaged by bollworms than the control. Quantitative reverse-transcription polymerase chain reaction (RT-PCR) showed that the CYP6AE1...

2011-01-01

229

Biophysical analysis of DNA modified by 1,2-diaminocyclohexane platinum(II) complexes  

Energy Technology Data Exchange (ETDEWEB)

Modification of DNA and double-stranded deoxyoligonucleotides with antitumor 1,2-diamino-cyclohexanedinitroplatinum(II) (Pt-dach) complexes was investigated with the aid of physico-chemical methods and chemical probes of nucleic acid conformation. The three Pt-dach complexes were used which differed in isomeric forms of the dach non-leaving ligand-Pt(1R,2R-dach), Pt(1S,2S-dach) and Pt(1R,2S-dach) complexes. The latter complex has lower antitumor activity than the other two Pt-dach complexes. Pt(1R,2S-dach) complex exhibits the slowest kinetics of its binding to DNA and of the conversion of monofunctional binding to bifunctional lesions. The anomalously slow electrophoretic mobility of multimers of the platinated and ligated oligomers suggests that bifunctional binding of Pt-dach complexes to a d(GG) site within double-stranded oligonucleotides induces bending of the oligomer. It is proposed that different effects of the Pt-dach complexes on DNA ...

1992-01-25

230

The role of lesions of DNA in senescence of seeds of Lupinus polyphyllus L. induced by chronic low-intensity irradiation  

International Nuclear Information System (INIS)

A nonlinear relationship between the time of accelerated aging of Lupine seeds and the indices of its survival as well as the single-strand DNA amount in cells from these seeds is established. The character of this relationship is essentially altered in chronically irradiated lupine seeds from the Chernobyl NPP exclusion zone and seems more complicated. The possible role of repair systems in these effects is discussed. The fact that chronic irradiation in low doses can modify the course of senescence in lupine seeds reflects its high biological efficiency comparing with acute irradiation.

2000-08-01

231

Programmed Assembly of Quantum-Dot Arrays on DNA Templates: Hardware for Quantum Computing?  

Energy Technology Data Exchange (ETDEWEB)

This paper reports progress in the fabrication and characterization of an array of 1nm-scale colloidal particles (i.e., quantum-dot array) that can be operated to execute nontrivial and innovative computations, possibly including quantum logic. We discuss the actual fabrication of 2-nm metal clusters as an example of possible quantum dot implementation. Innovative and unconventional paradigms underlie the different stages of this work. For example, regular array geometry is achieved by directing appropriately derivatized metal clusters to preselected locations along a stretched strand of an engineered DNA sequence.

2001-03-23

232

Locked nucleic acid (LNA): High affinity targeting of RNA for diagnostics and therapeutics  

DEFF Research Database (Denmark)

Locked nucleic acid (LNA) is a nucleic acid analogue containing one or more LNA nucleotide monomers with a bicyclic furanose unit locked in an RNA mimicking sugar conformation. This conformational restriction results in unprecedented hybridization affinity towards complementary single stranded RNA and thus, makes LNA uniquely suited for mimicking RNA structures and sequence specific targeting of RNA in vitro or in vivo. The focus of this paper is on LNAantisense, LNA-modified siRNA (siLNA), and detection and analysis of microRNAs by LNA-modified oligonucleotide probes.

2005-01-01

233

International cooperation - Information Centre - Research & Innovation - European Commission  

Wastenet

... Removal of this layer facilitates the unreeling of cocoons into long strands of silk comparable to those derived from the domesticated mulberry silkworm (Bombyx mori, B. mori). The research was funded in part by the SABIP ('Silks as biomimetic ideals for polymers) project, which has clinched a European Research Council (ERC) grant worth almost EUR 2.3 million under the EU's Seventh Framework Programme (FP7). Presented in the journal Biomacromolecules, the findings could lead to the development of new silk industries in ...

234

Generalization of proposed tendon friction correlation and its application to PCCV structural analysis  

Energy Technology Data Exchange (ETDEWEB)

The present paper dealt with the extension of tendon friction coefficient correlation as a function of loading end load and circumferential angle, proposed in the former paper. The extended correlation further included the effects of the number of strands contacted with sheath, tendon diameter, politicization of tendon and tendon local curvature. The validity of the correlation was confirmed by several published measured data. The structural analysis of middle cylinder part of 1/4 PCCV (Prestressed Concrete Containment Vessel) model was conducted using the present friction coefficient correlation. The results were compared with the analysis using constant friction coefficient, focused on the tendon tension force distribution. (author)

2000-12-01

235

Dipyrone-induced changes in DNA repair and other cell membrane associated processes in Escherichia coli  

Energy Technology Data Exchange (ETDEWEB)

The analgesic, dipyrone (1,phenyl-2,3-dimethyl-5-pyrazolone-4-methylamino methane sulphonate sodium), at 20 mM concentration, inhibited the rejoining of single-strand scissions in DNA of Escherichia coli B/r cells induced by 20 krad gamma-radiation. The chemical altered the cell membrane structure as evidenced from the uptake of acriflavin, the efflux of potassium ions from the bacterial cells and the inhibition of alkaline phosphatase-a cell membrane associated enzyme. (author). 18 refs., 6 figures.

1982-09-01

236

Dipyrone-induced changes in DNA repair and other cell membrane associated processes in Escherichia coli  

International Nuclear Information System (INIS)

The analgesic, dipyrone (1,phenyl-2,3-dimethyl-5-pyrazolone-4-methylamino methane sulphonate sodium), at 20 mM concentration, inhibited the rejoining of single-strand scissions in DNA of Escherichia coli B/r cells induced by 20 krad gamma-radiation. The chemical altered the cell membrane structure as evidenced from the uptake of acriflavin, the efflux of potassium ions from the bacterial cells and the inhibition of alkaline phosphatase-a cell membrane associated enzyme. (author).

237

Denaturation of Heterogeneous DNA  

CERN Document Server

The effect of pair-binding energy variations on the denaturation of double stranded DNAs is investigated. Using a two-parameter renormalization group (RG) analysis and extensive transfer matrix calculations, we find a random quenched-in variations to be marginally irrelevant, indicating that the system is self-averaging at the transition. The effect of a recently-proposed variable backbone stiffness is also investigated. Although irrelevant in the RG sense, it dramatically amplifies the randomness, leading to the appearance of ``multi-step melting'' for realistic sequences. These results are relevant to the adsorption of random heteropolymers and the wetting of disordered substrates.

1997-01-01

238

Comultiplication in link Floer homology and transversely non-simple links  

CERN Document Server

For a word w in the braid group on n-strands, we denote by T_w the corresponding transverse braid in the rotational symmetric tight contact structure on S^3. We exhibit a map on link Floer homology which sends the transverse invariant associated to T_{ws_i} to that associated to T_w, where s_i is one of the standard generators of B_n. This gives rise to a "comultiplication" map on link Floer homology. We use this to generate infinitely many new examples of prime topological link types which are not transversely simple.

2009-01-01

239

Afterlife Conceptions in the Vedas  

British Library Electronic Table of Contents (United Kingdom)

Abstract Continuity and change in ancient Indian afterlife conceptions are discussed in a broad overview of the most relevant Vedic texts (the Rig Veda, the Krishna Yajur Veda, the Atharva Veda, the Shatapatha Brahmana, the Jaiminiya Brahmana and the Upanishads). Despite the introduction of (or re-emphasis on) certain ideas, such as reincarnation and moksha (liberation from the cycle of death and rebirth), there is also continuity of a core set of conceptions from the earliest texts to the latest. Return-from-death narratives are also found in each textual strand, and are discussed separately.

2011-01-01

240

Groundwater penetrating radar and high resolution seismic for locating shallow faults in unconsolidated sediments  

Energy Technology Data Exchange (ETDEWEB)

Faults in shallow, unconsolidated sediments, particularly in coastal plain settings, are very difficult to discern during subsurface exploration yet have critical impact to groundwater flow, contaminant transport and geotechnical evaluations. This paper presents a case study using cross-over geophysical technologies in an area where shallow faulting is probable and known contamination exists. A comparison is made between Wenner and dipole-dipole resistivity data, ground penetrating radar, and high resolution seismic data. Data from these methods were verified with a cone penetrometer investigation for subsurface lithology and compared to existing monitoring well data. Interpretations from these techniques are compared with actual and theoretical shallow faulting found in the literature. The results of this study suggests that (1) the CPT study, combined with the monitoring well data may suggest that discontinuities in correlatable zones may indicate that faulting is present (2) the ...

1993-12-31

241

Revolutionary news on superconductivity  

Energy Technology Data Exchange (ETDEWEB)

A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)

1994-09-01

242

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

243

Laser applications. Final report  

Energy Technology Data Exchange (ETDEWEB)

Processes were developed that use lasers as manufacturing tools. These processes were stripping of insulation from cables and wires, machining of quartz, microdrilling and welding of reflective metals, and precision alignment of curved surfaces before machining. A technological basis also was formed which resulted in a process for automatic surface inspection of parts and aided development of machining processes for Kevlar parts.

1980-07-01

244

Interconnection France-England; Interconnexion France-Angleterre  

Energy Technology Data Exchange (ETDEWEB)

These documents defines the interconnection France-England rules for the 2000 MW DC submarine cable directly linking the transmission networks of England and Wales and France. Rights to use Interconnector capacity from 1 April 2001 are to be offered through competitive tenders and auctions, full details of which are set out in the Rules. The contract and a guide to the application form are provided. (A.L.B.)

2001-07-01

245

High temperature liquid level sensor  

International Nuclear Information System (INIS)

A length of metal sheathed metal oxide cable is perforated to permit liquid access to the insulation about a pair of conductors spaced close to one another. Changes in resistance across the conductors will be a function of liquid level, since the wetted insulation will have greater electrical conductivity than that of the dry insulation above the liquid elevation.

1983-03-01

246

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

248

Corona effect in high voltage transmission lines; O efeito corona em linhas eletricas aereas de alta-tensao  

Energy Technology Data Exchange (ETDEWEB)

Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.

1993-12-01

249

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

250

Comparison of thermochemically calculated and measured dioxin contents in the off-gas of a sinter plant  

Energy Technology Data Exchange (ETDEWEB)

Polychlorinated dibenzo-p-dioxins and dibenzo-furans form a family of more than 200 compounds which are relatively stable in the biosphere and tend to accumulate in the human body. The tetra- to hexa-chlorinated dioxins and furans are considered highly toxic. To facilitate the assessment of the total toxicity of dioxin and furan mixtures, the estimated toxic effects of the individual compounds relative to the 2,3,7,8-tetrachloro-dibenzo-p-dioxin (TCDD) were introduced as Toxic Equivalent Factors which yield, when multiplied with the respective concentrations, the Toxic Equivalent (TE) of the mixture. Toxic dioxins and furans are unintentionally formed in a number of industrial combustion processes such as waste incineration and iron ore sintering, in the chemical industry and in household heating. To keep the emissions as low as possible, off-gas clearing systems for the collection of dioxins and furans are increasingly prescribed by the authorities. In addition, it appears desirable ...

1997-12-31

251

Scour protection for wind turbine foundations on highly erodible sea bottom  

Energy Technology Data Exchange (ETDEWEB)

Scour around offshore structures is well known. It is caused by the strong eddy formation at the base of the structures protruding from the sea bottom. The strong vortices result in an amplified effective shear stress working on the sea bottom surface adjacent to the structure. When the surrounding sea bottom is lowered the scour protection will end up being a cap on a small hill and when the slopes are getting too steep the scour protection will roll or slide down the sides. It will loose its cohesion and therefore its integrity. This will take place irrespective of the type of scour protection material and the type of scour protection. This report describes scour protections, which can deal with this particular problem. Such a scour protection must be able to sustain the following loads: Be able to follow the lowering of the seabed on its way down; Be resistant to edge scour (scour around the perimeter of the scour protection). The installation of scour protection is not ...

2002-12-01

252

Development of process technology for large-area thin-film solar modules based on compound semiconductors. Final report; Entwicklung der technologischen Grundlagen fuer grosse Photovoltaikmodule auf Basis von Duennschicht-Verbindungshalbleitern. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

A cooperative effort of the Center for Solar Energy and Hydrogen Research (ZSW) and Phototronics Solartechnik GmbH (PST) aimed at the transfer of highly efficient solar cells developed on a laboratory scale, to large-area thin-film solar modules suitable for production. This work was based on research and development at the Institute for Physical Electronics (IPE) of Stuttgart University and ZSW on one hand, and on the know-how of PST in regard to large-area module fabrication on the other hand. The various thin-film layers of the cells and modules comprize molybdenum as rear contact, copper-indium(gallium)-diselenide (CIGS) as absorber material, the combination of cadmium sulphide (CdS) and ZnO as window layer. To produce these layers on large areas (30x30 cm{sup 2}), equipment was constructed and procedures were developed. Monolithic series connection of cells, used in other thin-film technologies, was studied and optimized by suitable patterning procedures, such as laser-scribing, ...

1998-06-01

253

Structural design and fabrication of the Sandia 34-meter Vertical Axis Wind Turbine  

Science.gov (United States)

The Wind Energy Research Division of Sandia National Laboratories has been funded by the Wind/Ocean Technology Division of the Department of Energy (DOE) to design and build a 34-meter diameter Vertical Axis Wind Turbine (VAWT). The turbine design incorporates the results of recent VAWT research in aerodynamics and structural dynamics. Initial system concept studies identified several blade options that met the required power rating of 500 kW. The final blade and rotor configurations were chosen based on finite element calculations that determined the turbine modes of response, their frequency of vibration, and stress levels. For parked survival turbine components were designed to with stand the loading of a 150 mph (67.0 m/s) wind coupled with maximum cable tensions. Specific areas of design discussed include the rotor, cables, bearings, brakes, and foundations. Construction of the turbine is in progress at this time and anticipated completion ...

1987-01-01

254

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to transmit data along the system, while the ...

1991-07-01

255

Transmission electron microscopy of undermined passive films on stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A study has been made of the passive film remaining over pits on stainless steel using a high resolution transmission electron microscope. Type 305 stainless steel was passivated in a borate buffer solution and pitted in ferric chloride. Passive films formed at 0.2 V relative to a saturated calomel electrode were found to be amorphous. Films formed at higher potentials showed only broad diffraction rings. The passive film was found to cover a remnant lacy structure formed over pits passivated at 0.8 V. The metallic strands of the lace were roughly hemitubular in shape with the curved surface facing the center of the pit.

1999-06-01

256

The temporal evolution of coronal loops observed by GOES-SXI  

CERN Document Server

We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional to the timescale of ...

2006-01-01

257

Mapping of the human cone transducin {alpha}-subunit (GNAT2) gene to 1p13 and negative mutation analysis in patients with Stargardt disease  

Energy Technology Data Exchange (ETDEWEB)

We report localization of the human cone transducin (GNAT2) gene using fluorescence in situ hybridization on chromosome 1 in band p13. The recent assignment of a gene for Stargardt disease to the same chromosomal region by linkage analysis prompted us to investigate the possible role of GNAT2 in the pathogenesis of this disease. We investigated 66 unrelated patients for mutations in the coding region of the GNAT2 gene using polymerase chain reaction-single strand conformation polymorphism analysis (SSCP) and direct sequencing. No disease-specific mutations were found, indicating that GNAT2 is probably not involved in the pathogenesis of most cases of Stargardt disease. 19 refs., 1 fig., 1 tab.

1995-01-01

258

Investigation by physical methods of the possible role of telomeres in DNA in aging process  

CERN Document Server

The interaction energies between the different types of bases of a single strand of DNA molecule have been calculated. Using these original values of energies the harmonic behavior of a number of base patterns of DNA has been studied. In view of the great interest aroused by the discovery of the role of the telomere segment of the DNA in the replication process and its possible link with the aging process, we have investigated, with simple models, the harmonic behavior of the telomeric pattern of bases as well as the thermodynamic response in the biological system. With these results a conclusion on the probable role of the telomeric pattern on aging has also been drawn. Here the calculated values of harmonic frequencies of the telomeric pattern of bases and of other possible patterns show that the telomeric pattern is associated with the highest vibrational frequency among all patterns of base combinations at the replication end of DNA. This seems to suggest that ...

2003-01-01

259

Important effects of neighbouring nucleotides on electron induced DNA single-strand breaks  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we present Quantum Mechanics/Molecular Mechanics (QM/MM) calculations on molecules containing a 2-deoxycytidine-3prime-monophosphate moiety (3prime-dCMPH). In particular, we examine the effect that including neighbouring nucleotides at the Molecular Mechanic (MM) level has on the calculated electron affinities and on the energetic barriers of the C3prime-O3prime bond cleavage. Our results demonstrate that the surrounding nucleotides relocate the excess electron from the p* orbital of the base to a diffuse phosphate-centred orbital, leading to the formation of a dipole-bound anion state. Both the electron affinities and the activation energy of C3prime-O3prime bond cleavage are strongly increased.

2009-01-01

260

Development and Demonstration of a High Efficiency, Rapid Heating, Low NOx Alternative to Conventional Heating of Round Steel Shapes, Steel Substrate (Strip) and Coil Box Transfer Bars  

Energy Technology Data Exchange (ETDEWEB)

Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiant heating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.

2010-01-25

261

Bounding bubbles: the vertex representation of 3d Group Field Theory and the suppression of pseudo-manifolds  

CERN Document Server

Based on recent work on simplicial diffeomorphisms in colored group field theories, we develop a representation of the colored Boulatov model, in which the GFT fields depend on variables associated to vertices of the associated simplicial complex, as opposed to edges. On top of simplifying the action of diffeomorphisms, the main advantage of this representation is that the GFT Feynman graphs have a different stranded structure, which allows a direct identification of subgraphs associated to bubbles, and their evaluation is simplified drastically. As a first important application of this formulation, we derive new scaling bounds for the regularized amplitudes, organized in terms of the genera of the bubbles, and show how the pseudo-manifolds configurations appearing in the perturbative expansion are suppressed as compared to manifolds. Moreover, these bounds are proved to be optimal.

2011-01-01

262

Bioinformatic analysis of BBTV satellite DNA in Hainan  

British Library Electronic Table of Contents (United Kingdom)

Banana bunchy top virus (BBTV), family Nanaviridae, genus Babuvirus, is a single stranded DNA virus (ssDNA) that causes banana bunchy top disease (BBTD) in banana plants. It is the most common and most destructive of all viruses in these plants and is widespread throughout the Asia-Pacific region. In this study we isolated, cloned and sequenced a BBTV sample from Hainan Island, China. The results from sequencing and bioinformatics analysis indicate this isolate represents a satellite DNA component with 12 DNA sequences motifs. We also predicted the physical and chemical properties, structure, signal peptide, phosphorylation, secondary structure, tertiary structure and functional domains of its encoding protein, and compare them with the corresponding quantities in the replication initiatio...

2011-01-01

263

Applications of CR-39 for the estimation of biological effects of heavy ion irradiation to DNA and living cells  

Energy Technology Data Exchange (ETDEWEB)

We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)

2001-10-01

264

A PAC containing the human mitochondrial DNA polymerase gamma gene (POLG) maps to chromosome 15q25  

Energy Technology Data Exchange (ETDEWEB)

The human mitochondrial DNA (mtDNA) is a closed circular, 16,569-bp double-stranded DNA, encoding 13 genes whose protein products are subunits of the oxidative phosphorylation system required for synthesis of most of the ATP consumed by eukaryotic cells. Point mutations of the mtDNA that cause multi-tissue, loss-of-energy syndromes, called mitochondrial encephalomyopathies (e.g., MERRF and MELAS), have been identified. In addition, large-scale deletions of the human mtDNA have been identified and are the molecular bases for the neonatal and adolescent onset loss-of-energy syndromes Pearson and Kearns-Sayer, respectively. 5 refs., 1 fig.

1997-03-01

265

Test de levage module QRL  

CERN Multimedia

Test de levage module QRL

2004-01-01

266

Underground electric-power transmission-system environmental impact assessment  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy, Division of Electric Energy Systems, has undertaken to identify the environmental issues and potential impacts associated with the installation of underground electric power transmission systems. This study reports the results of investigations into the advanced cable technologies being considered for future underground applications, as part of the development oriented research program of the Division of Electric Energy Systems. While the technology involves a high level of sophistication, there are relatively few impacts to the environment that are potentially significant, and of these none are inherently non-mitigable. Route planning, system design, and methods of construction and accident response can be pursued in order to minimize impacts where strict constraints are appropriate.

1982-03-01

267

Selected topics in transient response of aerial lines to high-altitude electromagnetic pulse  

International Nuclear Information System (INIS)

Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmission line model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)

2005-11-01

268

Kevlar, the 'universal fiber'. Properties and applications in industry, sports and recreation. Kevlar - die 'Alleskoenner-Faser'. Eigenschaften und Anwendung in Industrie, Sport und Freizeit  

Energy Technology Data Exchange (ETDEWEB)

This article gives a survey of the history, properties and applications of 'Kevlar' aramide fibers. For example, the 'Kevlar' para-aramide fiber is used in compound materials in ship-, aircraft- and vehicle construction. 'Kevlar' is used as a replacement for asbestos, for example in brakes, clutches and seals or as rubber reinforcement (tyres, conveyor belts, hoses). The aramide fibers also offer manufacturers of ropes, hawsers and cables a near ideal range of properties. (MM).

1988-12-01

269

Industrial processing of complex fluids: Formulation and modeling  

Energy Technology Data Exchange (ETDEWEB)

The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.

1997-08-01

270

An estimate of the response of a telephone repeater to a wideband pulse using FAAT techniques  

Energy Technology Data Exchange (ETDEWEB)

The purpose of a FAAT analysis is to estimate the probability of system upset to an electromagnetic threat, for systems on which we have incomplete information. As an example of this process, we will discuss the response of part of a telephone repeater system to wideband transients. We first estimate the currents induced on above-ground and buried cables. After that, we describe the simple circuit we used to build a model of the amplifier and protective devices. Finally, we describe the scaling of the energy deposited in the electronics, including its nonlinear large-signal response, with the amplitude of the wideband waveforms.

1992-09-01

271

2000 MW HVDC link between England and France  

Energy Technology Data Exchange (ETDEWEB)

The HVDC link across the English Channel, which was brought into service in 1986, has several innovative features. Techniques used in its construction together with recent developments have consolidated the viability of HVDC links for a variety of applications. Outlines the main features of the scheme, including the benefits of interconnecting the British and French 400 kV AC power systems; integration of the UK converter system to the 400 kV AC grid; the DC submarine cables; convertor equipment (particularly the UK installation); and future HVDC developments. 6 refs.

1987-03-01

274
275

Metals and alloys : atmospheric corrosion testing : General requirements for field tests  

CERN Document Server

Metals and alloys : atmospheric corrosion testing : General requirements for field tests

1992-01-01

277

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation doses (1-100 mGy) suggest that DNA ...

2007-09-15

278

Nanocrystal Bioassembly: Asymmetry, Proximity, and Enzymatic Manipulation  

Energy Technology Data Exchange (ETDEWEB)

Research at the interface between biomolecules and inorganic nanocrystals has resulted in a great number of new discoveries. In part this arises from the synergistic duality of the system: biomolecules may act as self-assembly agents for organizing inorganic nanocrystals into functional materials; alternatively, nanocrystals may act as microscopic or spectroscopic labels for elucidating the behavior of complex biomolecular systems. However, success in either of these functions relies heavily uponthe ability to control the conjugation and assembly processes.In the work presented here, we first design a branched DNA scaffold which allows hybridization of DNA-nanocrystal monoconjugates to form discrete assemblies. Importantly, the asymmetry of the branched scaffold allows the formation of asymmetric2assemblies of nanocrystals. In the context of a self-assembled device, this can be considered a step toward the ability to engineer functionally distinct inputs and outputs.Next we develop an ...

2008-05-01

279

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and III bands. Quantitative estimation using the ...

1993-03-01

280

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

International Nuclear Information System (INIS)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and III bands. Quantitative estimation using the curve fitting method ...

281

DNA damage intensity in fibroblasts in a 3-dimensional collagen matrix correlates with the Bragg curve energy distribution of a high LET particle  

International Nuclear Information System (INIS)

The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg curve profile with a pattern of DNA damage intensity similar to the physical Bragg curve for the ...

2010-03-01

282

Comparative removal of pyrimidine dimers from human epidermal keratinocytes in vivo and in vitro  

Energy Technology Data Exchange (ETDEWEB)

We have compared the kinetics for repair of UV-induced cyclobutane pyrimidine dimers in the DNA of keratinocytes in human skin and in cell culture. A small area of the buttocks of volunteers was exposed to UVB-irradiation and biopsies were taken at various time intervals. Epidermal keratinocytes in culture from the same subjects were exposed to UVC with doses chosen to elicit comparable yields of dimers in cellular DNA. The initial density of pyrimidine dimers and the kinetics of their removal were assessed utilizing the dimer-specific T4 endonuclease V and sedimentation of the unlabeled DNA through alkaline sucrose gradients. The position of DNA in the gradients was determined using a monoclonal antibody against random sequences of single-stranded DNA in a sensitive immunoassay. The initial dimer frequency was 3.9-6.7 per 10(8) daltons DNA. About 40% of the dimers were removed within 1 h, 70% in 6 h, and 90% in 24 h for both in vivo and in vitro samples. The early ...

1988-10-01

283

Comparative removal of pyrimidine dimers from human epidermal keratinocytes in vivo and in vitro  

International Nuclear Information System (INIS)

We have compared the kinetics for repair of UV-induced cyclobutane pyrimidine dimers in the DNA of keratinocytes in human skin and in cell culture. A small area of the buttocks of volunteers was exposed to UVB-irradiation and biopsies were taken at various time intervals. Epidermal keratinocytes in culture from the same subjects were exposed to UVC with doses chosen to elicit comparable yields of dimers in cellular DNA. The initial density of pyrimidine dimers and the kinetics of their removal were assessed utilizing the dimer-specific T4 endonuclease V and sedimentation of the unlabeled DNA through alkaline sucrose gradients. The position of DNA in the gradients was determined using a monoclonal antibody against random sequences of single-stranded DNA in a sensitive immunoassay. The initial dimer frequency was 3.9-6.7 per 10(8) daltons DNA. About 40% of the dimers were removed within 1 h, 70% in 6 h, and 90% in 24 h for both in vivo and in vitro samples. The early ...

1988-01-01

284

Consumable and Combustible Cartridge Cases.  

Science.gov (United States)

The procedure describes the procedures to be used in evaluating consumable and combustible cartridge cases. Included are ballistic tests, environmental tests, adverse condition tests, fungus resistance tests, drop tests and safety tests. (Author)

1966-01-01

285

Overhead power lines: overheating and electrodynamic stresses; Lignes aeriennes: echauffements et efforts electrodynamiques  

Energy Technology Data Exchange (ETDEWEB)

The flow of current inside a conductor leads to its overheating. This conductor is also submitted to other climatic phenomena, such as wind, sun light and ambient temperature. The knowledge of this overheating is important to ensure a functioning temperature compatible with the materials used for the conductor manufacturing and with the dip of overhead power lines above the ground and buildings. On the other hand, according to the Laplace works, the flow of current inside parallel conductors induces electromagnetic forces inside them, proportional to the product of currents in both conductors. In the case of short-circuit between aerial power lines or between flexible cables, electrodynamical stresses (traction and flexion) are applied to insulators and holders and important swinging of the lines can be observed. These stresses can be extremely important and must be considered in the design of overhead lines. These two phenomena are analyzed in this chapter. (J.S.)

1997-05-01

286

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

287

Ethernet networks technology in electrical substations  

Energy Technology Data Exchange (ETDEWEB)

In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent unauthorized access ...

2002-07-01

288

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

1998-01-01

289

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

1998-10-13

290

Development of uninterruptible power supply for CATV networks; CATV yo muteiden dengen kyokyuki no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

A UPS based on a line-interactive system for CATV (Cable TV) networks has been newly developed. An inverter of the UPS featuring a pure sine wave output and equipped with an uninterrupptible transfer switch made it possible to raise its reliability high and to reduce the uninterruptible transfer time from 50 {approx} 100 ms to only 3 ms. The expected life of 15 years and maintenance-free of the UPS were realized by monitoring and optimizing the operational conditions of lead-acid batteries, aluminum electrolytic capacitors and cooling fans. The use of rust- and weather- resistant painting methods for an outer box of the UPS also contributed to extend the life of the system. (author)

1998-12-25

291

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

293

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the determination of the Sn mass in the intermetallic Sn-Cu layer. (19 refs).

2004-01-01

294

Stability and cations coordination of DNA and RNA 14-mer G-quadruplexes: a multiscale computational approach.  

Science.gov (United States)

Molecular dynamics simulations have been used to study the differences between two DNA and RNA 14-mer quadruplexes of analogous sequences. Their structures present a completely different fold: DNA forms a bimolecular quadruplex containing antiparallel strands and diagonal loops; RNA forms an intrastrand parallel quadruplex containing a G-tetrad and an hexad, which dimerizes by hexad stacking. We used a multiscale computational approach combining classical Molecular dynamics simulations and density functional theory calculations to elucidate the difference in stability of the 2-folds and their ability in coordinating cations. The presence of 2'-OH groups in the RNA promotes the formation of a large number of intramolecular hydrogen bonds that account for the difference in fold and stability of the two 14-mers. We observe that the adenines in the RNA quadruplex play a key role in conserving the geometry of the hexad. We predict the cation coordination mode of the two ...

2008-09-03

295

Recent activites on electromagnetic processing of materials in Japan  

Energy Technology Data Exchange (ETDEWEB)

Application of electromagnetic forces to materials processing, so-called {open_quotes}electromagnetic processing of materials (EPM){close_quotes} has been recognized as cutting edge technology, especially in the fields of steelmaking and advanced materials processing in Japan. The history of EPM in Japan is mentioned and the background to promote EPM is described. The current status of research and development of EPM is shown briefly introducing several examples. Regarding the application of high-frequency magnetic field, two topics are dealt with. The first is the improvement of the surface quality of cast steel where an alternating magnetic field is imposed on the molten steel from the outside of the mold, and the second is the induction cold crucible where a considerably large amount of molten intermetallic compound is levitated. Examples of the application of DC magnetic field are the control of molten steel flow in a mold and the suppression of the mixing of steel in the ...

1995-01-01

296

Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies  

CERN Document Server

The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance from the ionizing ...

1997-01-01

297

Fiscal 1998 industrial science and technology R and D project. Research report on R and D of genome informatics technology (Development of stable oil supply measures using complex biosystem); 1998 nendo genome informatics gijutsu kenkyu kaihtsu seika hokokusho. Fukugo seibutsukei riyo sekiyu antei kyokyu taisaku kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This report describes the fiscal 1998 result on development of genome informatics technology. As comparative analysis technique of genes, the combination of electrophoresis and PCR was used. For improvement of the throughput and reproducibility of the technique, module- shuffling primers were used, and the multi(96)-arrayed capillary fragment analyzer was devised. The system detecting SNPs rapidly was also developed successfully. As analysis technology of DNA sequence by use of triple- stranded DNA formation, study was made on construction of long cDNA libraries, selective subtraction of specific sequences from libraries, and the basic technology of homologous cloning. Study was also made on each reaction step of IGCR technique for fast analysis, and specifications of a fluorescence transfer monitor. As modeling technique of genetic sequence information, the simulation model was developed for gene expression regulatory networks during muscle differentiation, and ...

1999-03-01

298

Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle label  

Energy Technology Data Exchange (ETDEWEB)

An electrochemical detection method for analyzing sequence-specific DNA using gold nanoparticle DNA probes and subsequent signal amplification step by silver enhancement is described. The assay relies on the electrostatic adsorption of target oligonucleotides onto the sensing surface of the glassy carbon electrode (GCE) and its hybridization to the gold nanoparticle-labeled oligonucleotides DNA probe. After silver deposition onto gold nanoparticles, binding events between probe and target were monitored by the differential pulse voltammetry (DPV) signal of the large number of silver atoms anchored on the hybrids at the electrode surface. The signal intensity difference permits to distinguish between the match of two perfectly matched DNA strands and the near-perfect match where just one base pair was wrong. Coupled with this 'nanoparticle-promoted' reduction of silver signal amplification method, the sensitivity of this electrochemical DNA ...

2002-10-03

299

Atomic force microscopy and surface-enhanced Raman scattering detection of DNA based on DNA-nanoparticle complexes  

Energy Technology Data Exchange (ETDEWEB)

We report a simple method for the label-free detection of double-stranded DNA using surface-enhanced Raman scattering (SERS). We prepared cetyltrimethylammonium bromide (CTAB)-capped silver nanoparticles and a DNA-nanoparticle complex by adding silver nanoparticles to {lambda}-DNA solutions. In the present study, the utilization of CTAB-capped silver nanoparticles facilitates the electrostatic interaction between DNA molecules and silver nanoparticles; at the same time, the introduction of DNA avoids adding aggregating agent for the formation of nanoparticle aggregates to obtain large enhancement of DNA, because the DNA acts as both the probe molecules and aggregating agent of Ag nanoparticles. Atomic force microscopy (AFM) studies show that the morphology of DNA-Ag nanoparticle complexes seems to be determined by the concentrations of the DNA and the nanoparticles. Surface-enhanced Raman scattering (SERS) studies show that the morphology of the complexes plays a ...

2009-03-25

300

Analysis of the 5{prime} region of PMS2 reveals heterogeneous transcripts and a novel overlapping gene  

Energy Technology Data Exchange (ETDEWEB)

The PMS2 gene encodes a protein that is involved in DNA mismatch repair and is mutated in a subset of patients with hereditary nonpolyposis colon cancer (HNPCC). The previously published PMS2 cDNA sequence lack an upstream in-frame stop codon preceding the presumptive initiating methionine. To evaluate the 5` terminus of the PMS2 coding region further, we isolated additional cDNA clones, RT-PCR products, and the corresponding 5` genomic segment of the PMS2 locus. The PMS2 gene transcripts were found to have heterogeneous but colinear 5` termini, one of which contained an in-frame termination codon preceding the initiating methionine. In addition, a novel gene encoding a 34.5-kDa polypeptide was found to initiate transcriptionally within PMS2 from the opposite strand. 23 refs., 5 figs., 2 tabs.

1995-09-20

301

PROBABILITY OF FAILURE OF THE TRUDOCK CRANE SYSTEM AT THE WASTE ISOLATION PILOT PLANT (WIPP)  

Energy Technology Data Exchange (ETDEWEB)

This probabilistic analysis of WIPP TRUDOCK crane failure is based on two sources of failure data. The source for operator errors is the report by Swain and Guttman, NUREG/CR-1278-F, August 1983. The source for crane cable hook breaks was initially made by WIPP/WID-96- 2196, Rev. O by using relatively old (1970s) U.S. Navy data (NUREG-0612). However, a helpful analysis by R.K. Deremer of PLG guided the authors to values that were more realistic and more conservative, with the recommendation that the crane cable/hook failure rate should be 2.5 x 10-6 per demand. This value was adopted and used. Based on these choices a mean failure rate of 9.70 x 10-3(1/yr) was calculated. However, a mean rate by itself does not reveal the level of confidence to be associated with this number. Guidance to making confidence calculations came from the report by Swain and Guttman, who stated that failure data could be described by lognormal distributions. This is ...

2000-05-01

302

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively on station ...

1995-07-01

303

Testing of solar cells for communication satellites  

International Nuclear Information System (INIS)

... cadmium sulfides communications electrons performance testing physical

304

FIELD CORROSION TESTS FOR COMPARISON OF ...  

Science.gov (United States)

... Accession Number : ADD457408. Title : FIELD CORROSION TESTS FOR COMPARISON OF CORROSIVITY IN JAPAN AND CHINA. ...

305

Breath Test for Chemicals (Volatile Organic Compounds)  

Science.gov (United States)

Breath Tests; Human Volunteers; Pilot Study

2011-09-16

306

TRACG post-test analysis of PANDA tests M3 and M2  

International Nuclear Information System (INIS)

The author describes the results of post-test analyses of PANDA transient (M-series) tests M2 and M3. The purpose of the PANDA post-test analysis activity is to demonstrate that TRACG is applicable for the calculation of long-term SBWR containment response to a LOCA. Comparisons between TRACG predictions and test measurements are presented and discussed in the dual context of what the test results show and the capability of TRACG to predict their key features

1997-04-14

307

Performance testing of the FMC Fresnel-Belt Concentrating Solar Collector  

Energy Technology Data Exchange (ETDEWEB)

The results of tests performed on the FMC Fresnel-Belt Solar Collector at the Midtemperature Solar Systems Test Facility are summarized. Tests were conducted over a temperature range from 100 to 250/sup 0/C. Test objectives are defined, test procedures are described, and test results and conclusions are given.

1980-01-01

308

Basic radiation sterilization properties of packaging materials  

International Nuclear Information System (INIS)

The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).

1984-11-28

309

Technical report templates  

Wastenet

Performance testing and ...Performance testing and commissioning In either an Authority-owned or a dedicated MRF, the Contracting Authority should ...Performance testing is done to demonstrate that the contractor is able to meet the guarantees given

310

Psychomotor Vigilance Test (PVT) Transition to Operations - HRR - Task  

Science.gov (United States)

Task, Psychomotor Vigilance Test (PVT) Transition to Operations ... Related Tasks (36). Task, Psychomotor Vigilance Test (PVT) on ISS. Common Item(s) ...

311

Construction, Geology, and Aquifer Testing of the Maalo Road ...  

Science.gov (United States)

... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...

2011-05-13

312

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...

313

Substance Flow Analyses of Organic Pollutants in Stockholm  

International Nuclear Information System (INIS)

This paper summarizes substance flow analyses for four organic substances in the City of Stockholm, Sweden: diethylhexyl phthalate (DEHP), alkylphenolethoxylates (APEO), polybrominated diphenylethers (PBDE) and chlorinated paraffins (CP). The results indicate that the stocks of APEO, PBDE and CP all are approximately 200-250 tonnes, whereas the DEHP stock is two orders of magnitude larger. Emissions can be linked to imported consumer goods such as electronics (PBDE) and textiles (APEO), and to construction materials (DEHP, CP). For several of the substances considerable amounts remain in the technosphere for a long time, even after use of the substance in new products has been eliminated. For example, the use of DEHP as plasticizer for PVC plastics in cables and floorings has more or less been phased-out, but still these applications make up a stock of some 20,000 tonnes (85% of the total DEHP stock in Stockholm) and emit 28 tonnes of DEHP annually (93% of overall ...

2008-12-01

314

Splice assembly tool and method of splicing  

Energy Technology Data Exchange (ETDEWEB)

A splice assembly tool for assembling component parts of an electrical conductor while producing a splice connection between electrical cables therewith, comprises a first structural member adaptable for supporting force applying means thereon, said force applying means enabling a rotary force applied manually thereto to be converted to a longitudinal force for subsequent application against a first component part of said electrical connection, a second structural member adaptable for engaging a second component part in a manner to assist said first structural member in assembling the component parts relative to one another and transmission means for conveying said longitudinal force between said first and said second structural members, said first and said second structural members being coupled to one another by said transmission means, wherein at least one of said component parts comprises a tubular elastomeric sleeve and said force applying means provides a ...

1980-01-01

315

Retractable barrier strip  

Energy Technology Data Exchange (ETDEWEB)

A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts ...

2002-01-01

316

Reasons for the power failure in Auckland, New Zealand; Ursachen der Stromunterbrechung in Auckland, Neuseeland  

Energy Technology Data Exchange (ETDEWEB)

On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am 21. Juli 1998 ...

1998-11-30

317

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside ...

2006-11-13

318

Open vs Closed Access Femtocells in the Uplink  

CERN Document Server

Femtocells are assuming an increasingly important role in the coverage and capacity of cellular networks. In contrast to existing cellular systems, femtocells are end-user deployed and controlled, randomly located, and rely on third party backhaul (e.g. DSL or cable modem). Femtocells can be configured to be either open access or closed access. Open access allows an arbitrary nearby cellular user to use the femtocell, whereas closed access restricts the use of the femtocell to users explicitly approved by the owner. Seemingly, the network operator would prefer an open access deployment since this provides an inexpensive way to expand their network capabilities, whereas the femtocell owner would prefer closed access, in order to keep the femtocell's capacity and backhaul to himself. We show mathematically and through simulations that the reality is more complicated for both parties, and that the best approach depends heavily on whether the multiple access scheme is ...

2010-01-01

319

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the ...

1992-01-01

320

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more ...

1986-01-01

321

Lead recycling; Namari no recycle  

Energy Technology Data Exchange (ETDEWEB)

In Japan, lead has been widely used for gasoline additives, inorganic chemicals such as pigment, lead pipes/plates, and coating materials of cable. Because of the steady increase in car population and the mounting of environmental concern, lead consumption ratio for lead-acid batteries is tending to increase gradually up to 70% with decreasing the consumption for gasoline additives. This paper describes the recycling of lead-acid batteries in Japan. Since the latter half of FY 1994, the battery manufacturing industry started the new lead recycling system. The recycling ratio of the used lead-acid batteries became 90% in 1996 from 84% in 1994. In near future, it can reach to 95%, the recycling ratio in some European countries. The primary smelting occupies 53%, and the secondary smelting occupies 47%. For the conventional method by secondary smelting makers, reduction smelting and copper removing of lead electrodes are conducted, and lead is recycled as tertiary ...

1997-12-25

322

Electroforming of metals: state-of-the-art assessment. Final report  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the state-of-the-art of electromagnetic and electrohydraulic forming of metal parts has been conducted. Electromagnetic forming (EMF) shapes parts by a force resulting from a high-density magnetic field. The electrohydraulic forming (EHF) process differs in that the force is applied to parts from a shock wave emanating from a point within a fluid medium. Both processes are used to form relatively thin-section hollow or flat products. This survey has found that, of the two electrotechnologies, the electromagnetic forming process is expected to be used increasingly in a broad range of industries, particularly for automotive, aircraft, and electrical-cable components. In contrast, the level of applications for the electrohydraulic forming method is expected to remain essentially unchanged over the near- and long-term period. This is because its use is restricted to relatively unusual part shapes in industries that do not require large unit quantities. ...

1986-07-01

323

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...

2007-07-01

324

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...

2007-05-10

328

Shield-verification survey of a large hot cell at the FFTF  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.

1980-01-01

333

Exploding Bridgewire Electrical System Test Unit.  

Science.gov (United States)

The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...

1964-01-01

334

Dobutamine stress test and beta-agonist - a potential concern for nuclear cardiology testing: a case report  

UK PubMed Central (United Kingdom)

IntroductionChest pain with ST-segment elevation is a rare clinical problem during dobutamine stress testing. Although beta-agonists treatment prior to dobutamine stress testing...Full Text Available

335

Coping with Test Pain, Discomfort, and Anxiety  

Science.gov (United States)

... Search Help? Coping with Test Pain, Discomfort, and Anxiety Introduction | Be Prepared | Know Your Tests | Relax | Conclusion ... though they may feel some embarrassment, discomfort, or anxiety at the outset. If undergoing medical tests makes ...

339

Sunflower turboalternator csu 1-3 2348 hour test summary report  

Science.gov (United States)

Performance and endurance testing of sunflower turboalternator combined shaft unit

1964-01-01

340

Sunflower power system test report topical report, nov. - 19 dec. 1962  

Science.gov (United States)

Sunflower power conversion system development test program

1964-01-01

341

Nondestructive Testing of Polymeric Composite Sandwich ...  

Science.gov (United States)

... Accession Number : ADD345858. Title : Nondestructive Testing of Polymeric Composite Sandwich Panels Via the Thermographic Halo,. ...

342

Motivation in vigilance - A test of the goal-setting hypothesis of the effectiveness of knowledge of results.  

Science.gov (United States)

This study tested the prediction, derived from the goal-setting hypothesis, that the facilitating

1973-01-01

343

Experimental Testing of a Combustible Case for the 155mm ...  

Science.gov (United States)

... Descriptors : *INTERIOR BALLISTICS, *COMBUSTIBLE CARTRIDGE CASES, FIRING TESTS(ORDNANCE), EXPLOSIVE CHARGES, ARTILLERY ...

1982-03-01

344

ELECTROMAGNETIC MATERIALS TESTING USING RL AND ...  

Science.gov (United States)

... Accession Number : ADD318302. Title : ELECTROMAGNETIC MATERIALS TESTING USING RL AND RC-MULTIVIBRATORS. Corporate Author : ...

1985-02-01

345

CHLOROPICRIN LEAKAGE TEST OF THE M17 PROTECTIVE ...  

Science.gov (United States)

... CHLOROPICRIN LEAKAGE TEST Of THE M17 PPRDOtCTIVE MASK EQUIPPED WITH DRINKING AND RESUSCITATION DEVICIS WORN BY ...

1965-10-01

346

A Review of Test Medium Contamination Effects on Test ...  

Science.gov (United States)

... solid particle contamination. Solid particulate impact is a good mechanism for surface heat transfer augmentation. The aug ...

1998-01-01

347

Project W-314 Polyurea Special Protective Coating (SPC) Test Plan Chemical Compatibility and Physical Characteristics Testing  

Energy Technology Data Exchange (ETDEWEB)

This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.

2001-01-15

348

The Decommissioning of the Trino Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

Following a referendum in Italy in 1987, the four Nuclear Power Plants (NPPs) owned and operated by the state utility ENEL were closed. After closing the NPPs, ENEL selected a ''safestore'' decommissioning strategy; anticipating a safestore period of some 40-50 years. This approach was consistent with the funds collected during plant operation, and was reinforced by the lack of both a waste repository and a set of national free release limits for contaminated materials in Italy. During 1999, twin decisions were made to privatize ENEL and to transform the nuclear division into a separate subsidiary of the ENEL group. This group was renamed Sogin and during the following year, ownership of the company was transferred to the Italian Treasury. On formation, Sogin was asked by the Italian government to review the national decommissioning strategy. The objective of the review was to move from a safestore strategy to a prompt decommissioning strategy, with ...

2002-02-27

349

Structural Insights into the Interaction of the Evolutionarily Conserved ZPR1 Domain Tandem with Eukaryotic EF1A, Receptors, and SMN Complexes  

Energy Technology Data Exchange (ETDEWEB)

Eukaryotic genomes encode a zinc finger protein (ZPR1) with tandem ZPR1 domains. In response to growth stimuli, ZPR1 assembles into complexes with eukaryotic translation elongation factor 1A (eEF1A) and the survival motor neurons protein. To gain insight into the structural mechanisms underlying the essential function of ZPR1 in diverse organisms, we determined the crystal structure of a ZPR1 domain tandem and characterized the interaction with eEF1A. The ZPR1 domain consists of an elongation initiation factor 2-like zinc finger and a double-stranded {beta} helix with a helical hairpin insertion. ZPR1 binds preferentially to GDP-bound eEF1A but does not directly influence the kinetics of nucleotide exchange or GTP hydrolysis. However, ZPR1 efficiently displaces the exchange factor eEF1B from preformed nucleotide-free complexes, suggesting that it may function as a negative regulator of eEF1A activation. Structure-based mutational and complementation analyses reveal ...

2007-01-01

350

Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent  

Energy Technology Data Exchange (ETDEWEB)

To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who ...

2002-07-01

351

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. This is due to the low efficiency for both low and high LET ...

2002-03-01

352

Mapping of the human cone transducin {alpha} subunit (GNAT2) gene to 1p13 and mutation analysis in patients with Stargardt`s disease  

Energy Technology Data Exchange (ETDEWEB)

Transducin {alpha} subunits are members of a large family of G-proteins and play an important role in phototransduction in rod and cone photoreceptors. We report the localization of the human cone {alpha} transducin (GNAT2) gene using fluorescence in situ hybridization (FISH) on chromosome 1 in band p13. The recent assignment of a gene for Stargardt`s disease to the same chromosomal region by linkage analysis prompted us to investigate the possible role of GNAT2 in the pathogenesis of this disease. Stargardt`s disease is characterized by degeneration in late childhood or early adulthood of the macula of the retina, a region rich in cones. We screened patients with Stargardt`s disease, with or without peripheral cone involvement as monitored by the full-field ERG, for mutations in this gene. We investigated 66 unrelated patients including 22 with peripheral cone dysfunction for mutations in the coding region of the GNAT2 gene using polymerase chain reaction-single ...

1994-09-01

353

Immunological detection and quantification of DNA components structurally modified by alkylating carcinogens, mutagens and chemotherapeutic agents  

International Nuclear Information System (INIS)

The detection and quantification of defined reaction products of chemical mutagens and carcinogens (and of many cancer chemotherapeutic agents) with DNA require highly sensitive analytical techniques. The exceptional capability of immunoglobulins to recognize subtle alterations of molecular structure (especially when monoclonal antibodies are used to maximize specificity), outstanding sensitivity of immunoanalysis by high-affinity antibodies, and the fact that radioactively-labelled agents are not required suggest the utility of a radioimmunoassay to recognize and quantitate alkylated DNA products. We have recently developed a set of high-affinity monoclonal antibodies (secreted by mouse x mouse as well as by rat x rat hybridomas; antibody affinity constants, 10"9 to > 10"1"0 lmol) specifically directed against several DNA alkylation products with possible relevance in relation to both mutagenesis and malignant transformation of mammalian cells. These alkylation products include ...

1983-09-01

354

Dose conversion factor for radon concentration in indoor environments using a new equation for the F-f_p correlation  

International Nuclear Information System (INIS)

Since 1994 the radon studies group at the Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya in Barcelona, Spain, has carried out a campaign of continuous measurements of the equilibrium factor (F) and the unattached fraction (f_p) of radon decay products at four sites which are representative of different environmental characteristics on the Mediterranean littoral of Catalonia, Spain. It has been established that these parameters vary widely, F(0.03--0.87) and f_p (0--0.72), from one site to another and with time, according to the characteristics on the site and climate. In spite of this variation, the F and f_p parameters are log-normally or normally distributed. The measurements of F and f_p show that f_p is negatively correlated to F by a log-power equation, Ln(1/f_p)=1.90[Ln(1/F)]"-"0"."6"8, which can be used in all the F range, instead of the commonly used power equation f_p=aF"b suggested by Stranden and Strand and other ...

2000-01-01

355

DNA rearrangements from #gamma#-irradiated normal human fibroblasts preferentially occur in transcribed regions of the genome  

International Nuclear Information System (INIS)

Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of the affected cell. Ionizing radiation-induced DNA rearrangements were detected in ...

2003-08-17

356

Burning of droplets and particles of explosives  

Energy Technology Data Exchange (ETDEWEB)

Small droplets of organic diazides investigated by C.K. Law and coworkers burn in hot gas at 1 atm with rates inversely proportional to the droplet diameter presumably owing to leading chemical reaction proceeds in gas phase. These burning rates are obviously much lower than those obtained by extrapolation of the results measured for the some substances in glass tubes (at pressure of about 10{sup -2}-10{sup -1} atm, and temperature 0-100 deg C) on the burning conditions of the droplets. Kinetic constants estimated using Zel`dovich equation for the burning rate in gas phase and Semenov relation for delay time of the droplets micro-explosion in liquid phase are about the same: E {approx_equal} 0.17 MJ/mol, log{sub 10}k{sub o} {approx_equal} 15(S{sup -1}). In both of the cases the leading chemical reaction is supposed to be of the first order. Landau instability is assumed to be reflected in distortion of the droplets at burning but, as opposed to the liquids pools or columns burning, it ...

1996-12-31

357

Building a Construction Curriculum for Your School District  

Science.gov (United States)

Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with science, math, and economics teachers using the data as teaching tools within classrooms. Teachers can also ...

2010-06-01

358

Apoptotic pathways as regulators of recombination  

International Nuclear Information System (INIS)

Apoptosis, or programmed cell death (PCD), is a fundamental process that protects organismal integrity. In earlier work, we demonstrated that over-expression of either of two anti-apoptotic members of the BCL-2 family (BCL-2 or BCL-X L could elevate the frequency of radiation-induced mutations at the autosomal TK1 locus in human TK6 lymphoblasts that express wild-type TP53. Ectopic expression of BCL-X L also elevated the frequencies of double-strand break-induced gene conversion. The purpose of this study is to determine if BCL-2 family proteins promote radiation mutagenesis indirectly through their suppression of PCD, or whether the 'pro-mutagenic' function of these proteins can be separated from their anti-apoptotic function. We developed stable transfectants of TK6 cells that express a mutated form of BCL-X L with a single amino acid substitution in the BH1 domain that is known to interfere with the ability to suppress PCD (BCL-X L gly159ala). We also developed ...

2003-08-17

359

An investigation of some Turkish herbal medicines in Salmonella typhimurium and in the COMET assay in human lymphocytes.  

Science.gov (United States)

Medicinal plants play a major role in the life of Turkish people and of late medicinal plant usage has increased in many countries. Green plants in general contain mutagenic and carcinogenic substances, but there is little information about the biological activities of herbal medicine. In the present study, therefore, various Turkish medicinal herbs were investigated for their genotoxic potential in the Salmonella typhimurium microsomal activation assay and the alkaline single cell gel electrophoresis (COMET) assay. Extracts from these medicinal herbs and some fractions of these extracts were examined. The species investigated were Arctium minus, Ecballium elatterium, Momordica charantia, Plantago major, Urtica dioica, Viscum album, Salvia triloba, Euphorbia rigida, Stachys lavandulifolia, Acteoside, Abies nordmannia. They are used for various immune disorders and are applied either topically or taken orally as a herbal tea. Of the 19 samples of the extracts and fractions investigated, ...

1996-01-01

360

3-Methyl-3-deazaadenine, a stable isostere of N3-methyl-adenine, is efficiently bypassed by replication in vivo and by transcription in vitro.  

Science.gov (United States)

The goal of the present work was to determine the impact of N3-methyladenine (3-mA), an important lesion generated by many environmental agents and anticancer drugs, on in vivo DNA replication and in vitro RNA transcription. Due to 3-mA chemical instability, the stable isostere 3-methyl-3-deazaadenine (3-m-c(3)A) was site specifically positioned into an oligodeoxynucleotide. The oligomer was, then incorporated into a vector system that is rapidly converted to ssDNA inside yeast cells and requires DNA replication opposite the lesion for plasmid clonal selection. For control purposes, an adenine or a stable apurinic/apyrimidinic (AP)-lesion was placed at the same site. The presence of each lesion in the oligonucleotide was confirmed by MALDI-TOF analysis. Plasmids were then transfected into yeast cells. While the AP-site dramatically reduced plasmid replication in all strains, the 3-m-c(3)A had a slight effect in the rad30 background which significantly increased only in a rev3rad30 ...

2011-06-14

361

Guide to good practices for the development of test items  

Energy Technology Data Exchange (ETDEWEB)

While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. This guide is intended to be a supplement by providing more detailed guidance on the development of specific test items. This guide addresses the development of written examination test items primarily. However, many of the concepts also apply to oral examinations, both in the classroom and on the job. This guide is intended to be used as guidance for the classroom and laboratory instructor or curriculum developer responsible for the construction of individual test items. This document focuses on written test items, but includes information relative to ...

1997-01-01

362

Overview of reliability test program on primary coolant piping of light water reactors  

Energy Technology Data Exchange (ETDEWEB)

Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB verification tests, pipe fracture ...

1993-10-01

363

Fuels and materials testing capabilities in Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...

1989-07-01

364

Fuels and materials testing capabilities in Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...

365

Accelerated stability test techniques for middle distillate fuels  

Energy Technology Data Exchange (ETDEWEB)

Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety ...

1981-01-01

366

The first PANDA tests  

International Nuclear Information System (INIS)

The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be ...

367

The PANDA facility and first test results  

International Nuclear Information System (INIS)

The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly ...

368

Performance evaluation of 15-kV polymeric insulators for dead-end type applications on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the test results of a research program to investigate the performance of polymeric insulators for 15-kV dead-end applications on distribution systems. The test program involved both new insulators from five different manufacturers and naturally-aged insulators removed from service on the distribution system of Pennsylvania Power and Light. The test series to evaluate the new insulators included: preconditioning treatments, salt fog and tracking wheel accelerated aging tests, electrical tests, and material and physical tests. The tests for the naturally-aged insulators were mainly limited to the electrical tests and the material and physical tests.

1989-04-01

369

Telephone communications on a face with two steep machine tracks - tests with the mobile X-phone  

Energy Technology Data Exchange (ETDEWEB)

The author gives an account of tests with the X-phone system. The aim of the tests was to establish the reliability and behaviour of the apparatus mounted on a winning machine and to investigate the possibility of setting up a radio link, without laying an extra wire, between the foot of the tubbing-lined roadway and the winning machine on a steep face. The author describes the face and the test conditions and presents details of the satisfactory test results.

1981-11-01

370

Irradiation test program for FFTF  

International Nuclear Information System (INIS)

Four unique deisgn features are described which make the Fast Flux Test Facility eminently suitable for irradiation test programs. These features are a fast flux level of 7 x 10"1"5 neutrons/cm"2/sec, a 36-inch reference (breeder reactor) core height, test volumes suitable for testing of statistical quantities of materials, and the capability for direct (contact) or indirect (proximity) instrumentation of active core experiments.

371

Development of LMFBR safety testing in FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) will provide a prototypic test environment for advanced fuels and materials development within the U. S. LMFBR program. As a fast test reactor, the FFTF also provides a potentially unique capability for conduct of safety experimentation relevant to selected LMFBR safety issues associated with postulated core disruption events. The utility and feasibility of possible extension of FFTF testing into the area of safety research is being investigated. 5 fig.

1976-10-01

372

Accelerated aging tests with a resid hydrotreating catalyst  

International Nuclear Information System (INIS)

The author discusses the accelerated aging tests performed using Hondo and Maya as aging resids with a commercial large pore hydrotreating catalyst. The results from these tests were compared with those obtained under a normal full life test. The test resid was a sample of a typical refinery charge and the activities for sulfur and vanadium removal were determined at 720"0F after successive brief periods of exposure to the heavier oils.

1988-12-02

373

A SAS macro for a clustered logrank test  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The clustered logrank test is a nonparametric method of significance testing for correlated survival data. Examples of its application include cluster randomized trials where groups of patients rather than individuals are randomized to either a treatment or a control intervention. We describe a SAS macro that implements the 2-sample clustered logrank test for data where the entire cluster is randomized to the same treatment group. We discuss the theory and applications behind this test as well as details of the SAS code.

2011-01-01

374

Wind Characteristics at the Vawt Test Facility.  

Science.gov (United States)

A limited program of field measurements was undertaken in order to define the wind characteristics of the DOE/Sandia vertical axis wind turbine test facility. Because micrometeorological conditions under which a particular wind turbine is tested may have ...

1978-01-01

375

Thin Film Solar Cells and Solar Cell Testing, Volume II Proceedings of the Fourth Photovoltaic Specialists Conference  

Science.gov (United States)

Thin film solar cells and solar cell testing - photovoltaic cells, radiation damage to cadmium sulfide solar cells, and airplane testing of solar cells

1964-01-01

376

Testing program for development of a high pressure, multi-product, fluid swivel  

Energy Technology Data Exchange (ETDEWEB)

This paper defines a rigorous seal test program conducted to develop a functional and proven high-pressure, multi-product swivel suitable for use as a Floating Production Storage and Offloading (FPSO) unit for the transfer of liquids and gases at high pressures and high temperatures through a rotating system. The test program was accomplished with specially designed test equipment with computer monitoring of temperature, torque, fluid pressures, seal lip temperatures, number of cycles, and leakage. The three primary phases are: (A) Seal Laterial screening with a computer-automated Falex testing machine, plus physical testing of chemically exposed samples. (B) One-third scale testing of several seal system configurations using a hydraulic driven, computer controlled test machine. (C) Full scale testing of prototype ...

1985-01-01

377

Test design description; Volume 1B: Part 1, Fuel pins for the FSP-1R FFTF test assembly (HF191A): Revision 1  

Energy Technology Data Exchange (ETDEWEB)

The addition of rhenium clad pins to the FSP-1R test matrix is shown in this revision. Also attached are other updates to the TDD-IB, Part 1.

1989-12-20

378

Statistical methods for the blood beryllium lymphocyte proliferation test.  

UK PubMed Central (United Kingdom)

The blood beryllium lymphocyte proliferation test (BeLPT) is a modification of the standard lymphocyte proliferation test that is used to identify persons who may have chronic beryllium disease. A major...Full Text Available

1996-10-01

379

Seismic Testing of Wolsung-1 Steam Generator Models.  

Science.gov (United States)

This 1978 annual report contains the results of ''Seismic testing of Wolsung-1 steam generator model'' which was initiated in 1977 as a part of a study on nuclear components testing. Model 78, improved version of Model 77 which did not take into account f...

1979-01-01

380

Seismic Testing of Reactor Components.  

Science.gov (United States)

This report is the final report on the seismic testing of reactor components conducted since 1977 with opening of the vibration laboratory at KAERI. In 1979, forced vibration testing of Wolsung-1 steam generator model using sine dwell and white nosie rand...

1980-01-01

381

Results of Source Emissions Testing. UTC Fuel Cell Model ...  

Science.gov (United States)

... Results of Source Emissions Testing UTC Fuel Cell Model PC25C ... Results of Source Emissions Testing: UTC Fuel Cell Model PC25C ...

2004-09-01

382

Quantitation of Antibody to Non-Hemagglutinating Viruses by Single Radial Hemolysis: Serological Test for Human Coronaviruses  

UK PubMed Central (United Kingdom)

A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available

1977-06-01

383

Identification of the Response Parameters of a Geothermal Field During a Non-Isothermal Short Time Water Injection Test.  

Science.gov (United States)

Various methods to analyse the effect of a non-isotherme water injection on the pressure evolution during a test on a double geothermal well are investigated. Then, several types of injection test are simulated with experimental data to examine the condit...

1983-01-01

384

Effectively use corrosion testing  

Energy Technology Data Exchange (ETDEWEB)

The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables involved, while laboratory ...

1995-04-01

385

Corrosion test and service result of materials used for fuel injection nozzles in marine diesel engines  

Energy Technology Data Exchange (ETDEWEB)

Corrosion test, as a material selection test method of nozzle to be used in the marine diesel engine, was adopted and discussed. Due to the heightening in output power and lengthening in stroke of the marine diesel engine, the fuel injection nozzle became so severe in working condition that the nozzle tip became in lift 1/6 to 1/18 time as long as that of short stroke type in past. Then upon investigating cause of damage, the damage was confirmed to be mainly caused by the high temperature sulfidization corrosion. Then by preparing 20 kinds of candidate test piece and making sulfidization corrosion test in accordance with the high temperature corrosion test procedure, corrosiveness was evaluated through change in weight between before and after testing. As a result of testing, three kinds of test piece, inclusive of high ...

1989-06-15

386

13th Meeting of the Scientific Group on Methodologies for the Safety Evaluation of Chemicals (SGOMSEC): alternative testing methodologies for organ toxicity.  

UK PubMed Central (United Kingdom)

In the past decade in vitro tests have been developed that represent a range of anatomic structure from perfused whole organs to subcellular fractions. To assess the use of in vitro tests for toxicity...Full Text Available

1998-04-01

387

Treatment technology for transuranic waste streams: Cementation, vitrification, and incineration testing for the treatment of spent ion exchange media  

Energy Technology Data Exchange (ETDEWEB)

This document reports the results of testing of spent ion exchange media pretreatment technologies. Emphasis of the testing activities has been on screening pretreatment technologies, such as drying and emulsification, which are compatible with vitrification, cementation, and incineration. Ion exchange media tested for cementation and incineration pretreatment technologies were typical organic ion exchange resins and inorganic zeolites. The ion exchange medium tested for vitrification pretreatment technologies was inorganic zeolite. The results of testing activities are discussed in detail in this report.

1992-04-01

388

Results of thermal performance evaluation of the Owens-Illinois Sunpak liquid solar collector at indoor conditions  

Science.gov (United States)

This report provides test results on the thermal performance of an Owens-Illinois Sunpak liquid, evacuated tube, solar collector under simulated conditions. The test was conducted using the Marshall Space Flight Center Solar Simulator in accordance with the test requirements specified in ASHRAE 93-77 (Method of Testing to Determine the Thermal Performance of Solar Collectors) and the procedures contained in MTCP-FA-SHAC-400 (Procedure for Operation of the MSFC Solar Simulator Facility). The tests were performed on a module used on the early demonstration projects. A current production module is undergoing tests with results to be in a subsequent report.

1979-10-10

389

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

390

Evaluation test on the thermal stability of resin as neutron shielding material for spent fuel transport cask  

Energy Technology Data Exchange (ETDEWEB)

Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)

1998-07-01

391

Evaluation test on the thermal stability of resin as neutron shielding material for spent fuel transport cask  

International Nuclear Information System (INIS)

Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)

1998-05-10

392

An overview of FFTF [Fast Flux Test Facility] contributions to Liquid Metal Reactor Safety  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has provided a very useful framework for testing the advances in Liquid Metal Reactor Safety Technology. During the licensing phase, the switch from a nonmechanistic bounding technique to the mechanistic approach was developed and implemented. During the operational phase, the consideration of new tests and core configurations led to use of the anticipated-transients-without-scram approach for beyond design basis events and the move towards passive safety. The future role of the Fast Flux Test Facility may involve additional passive safety and waste transmutation tests. 26 refs.

1990-11-11

393

Testing of abrasion materials  

Energy Technology Data Exchange (ETDEWEB)

A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions ...

1983-06-01

394

Reproducibility of the Radiant Panel Test Method (ASTM E ...  

Science.gov (United States)

... Abstract : Interlaboratory evaluation of the Radiant Panel Method (ASTM E 162-67) for flame spread testing of two flexible foam and one hardboard ...

1977-03-01

395

Pre-test report on international round robin analysis of BARC containment (BARCOM) test model  

International Nuclear Information System (INIS)

BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model

2009-01-01

396

Ovine reference materials and assays for prion genetic testing  

UK PubMed Central (United Kingdom)

BackgroundGenetic predisposition to scrapie in sheep is associated with several variations in the peptide sequence of the prion protein gene (PRNP). DNA-based tests...Full Text Available

397

Mixed waste disposal facility at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

This report provides a brief overview of the history and planning for a proposed mixed waste disposal site on the Nevada Test Site. 8 figs.

1987-01-01

398

Medical Aspects of Sickle Hemoglobin in Military Personnel  

UK PubMed Central (United Kingdom)

The Department of Defense (DOD) will soon issue a directive to test all incoming military personnel for the presence of hemoglobin S. The military testing program for hemoglobin S is an occupational...Full Text Available

1977-01-01

399

Instrumeted Impact Testing of Composite Sandwich Panels,  

Science.gov (United States)

... Accession Number : ADD442819. Title : Instrumeted Impact Testing of Composite Sandwich Panels,. Corporate Author : AUBURN UNIV AL. ...

1989-05-01

400

In Situ Seismic Investigation of Folsom Dam and Reservoir ...  

Science.gov (United States)

... An explosive charge (exploding bridgewire (EBW) detonator) was used for the crosshole P-wave tests. For the crosshole S-wave tests a ...

1989-09-01

401

Experimental and analytical studies of pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.

1987-09-01

402

EVALUATION OF AMMONIUM NITRATE, ALUMINUM ...  

Science.gov (United States)

... 24 5 Exploding Bridgewire Test Vehicle.... . 0..... 25 ... 18 7 Results of Exploding Bridgewire TestLng of TP-41 and TP-41 Mixtures ..... ...

1964-05-14

403

DESIGN, MANUFACTURE, DEVELOPMENT, TEST, AND EVALUATION OF BORON ...  

Science.gov (United States)

the shear-beam design and the larger scale component test specimen. The subcompo - nents designed were: a. Web splice specimen. ...

404

Colonoscopy  

Medline Plus

... experts agree-- a colonoscopy is the most accurate test to detect the cancer, but because of cost ... method. Dr. Randall Burt: Colonoscopy is the best test. The question is therefore shouldn't everyone, since ...

405

Chemical Carcinogenesis Testing and Related Issues ...  

Science.gov (United States)

... 6 lit. CHEMICAL CARCINOGENESIS TESTING AND RELATED ISSUES- ILn SUBCHRONIC STUDIES AND RELATED ISSUES 0 o Andrew Sivak 0 ...

1985-05-01

406

Brief summary of reactor core component welding for the Fast Flux Test Facility (FFTF)  

International Nuclear Information System (INIS)

Included are descriptions of welding methods and joint design, welding equipment, and qualification tests.

1974-04-25

407

A Notional Battlespace for Simulating and Testing Dynamic ...  

Science.gov (United States)

... 23 Milstar 25 A Notional Battlespace For Dynamic Wireless Network Simulation/Testing ... Figure 16: GPS Satellite 23 Figure 17: Milstar Satellite 25 ...

2006-06-01

408

Sequence analysis of the ATM gene in 20 patients with RTOG grade 3 or 4 acute and/or late tissue radiation side effects  

International Nuclear Information System (INIS)

Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late tissue radiation side effects by reaction severity. DNA from the ...

1999-07-15

409

Results of reliability test program on light water reactor piping  

Energy Technology Data Exchange (ETDEWEB)

The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In the pipe rupture test, the influence of ...

1994-12-01

410

Four-inch pipe whip test under BWR LOCA conditions effect of overhang length  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the ...

1983-03-01

411

Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research  

Energy Technology Data Exchange (ETDEWEB)

JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the ...

2001-03-01

412

p73 protein regulates DNA damage repair.  

Science.gov (United States)

Although the p53 tumor suppressor is relatively well characterized, much less is known about the functions of other members of the p53 family, p73 and p63. Here, we present evidence that in specific pathological conditions caused by exposure of normal cells to bile acids in acidic conditions, p73 protein plays the predominant role in the DNA damage response. These pathological conditions frequently occur during gastric reflux in the human esophagus and are associated with progression to esophageal adenocarcinoma. We found that despite strong DNA damage induced by bile acid exposure, only p73 (but not p53 and p63) is selectively activated in a c-Abl kinase-dependent manner. The activated p73 protein induces DNA damage repair. Using a human DNA repair PCR array, we identified multiple DNA repair genes affected by p73. Two glycosylases involved in base excision repair, SMUG1 and MUTYH, were characterized and found to be transcriptionally regulated by p73 in DNA damage ...

2011-09-01

413

Video equipment of tele dosimetry and audio  

International Nuclear Information System (INIS)

To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the installation of two ...

2007-07-01

414

Renewable energy technology for off-grid power generation solar hybrid system  

International Nuclear Information System (INIS)

Off-grid power generation is meant to supply remote or rural area, where grid connection is almost impossible in terms of cost and geography, such as island, aborigine's villages, and areas where nature preservation is concern. Harnessing an abundance renewable energy sources using versatile hybrid power systems can offer the best, least-cost alternative solution for extending modern energy services to remote and isolated communities. The conventional method for off-grid power generation is using diesel generator with a renewable energy (RE) technology utilizing solar photovoltaic, wind, biomass, biogas and/or mini/micro hydro. A hybrid technology is a combination of multiple source of energy; such as RE and diesel generator and may also include energy storage such as battery. In our design, the concept of solar hybrid system is a combination of solar with diesel genset and battery as an energy storage. The main objective of the system are to reduce the cost of operation and ...

2006-12-01

415

CNN Newsroom Classroom Guides, October 2000.  

Science.gov (United States)

These classroom guides, designed to accompany the daily CNN (Cable News Network) Newsroom broadcasts for the month of October 2000, provide program rundowns, suggestions for class activities and discussion, student handouts, and a list of related news terms. Top stories include: Chinese authorities detain Falun Gong protesters on Tiananmen Square and Pope John Paul II angers China by canonizing Chinese martyrs, U.S. presidential candidates prepare for the first presidential debate, U.S. presidential candidates debate education issues, Danville, Kentucky prepares for the first U.S. vice presidential debate, and Yugoslav protesters seize parliament (October 2-6); Yugoslavian president Vojislav Kostunica takes office, recent clashes between Arabs and Israelis concern neighboring Arab states, North Korea observes 55 years of communism with celebrations, Al Gore and George W. Bush meet in the second presidential debate, and Violence in the Mideast and an attack on a ...

1999-12-01

416

A smart location system  

Energy Technology Data Exchange (ETDEWEB)

Details of a novel intelligent pipeline anomaly location system were presented. The system was based on the emission and reception of extra low frequencies(ELF) disposed close to a pipeline that were then logged in the memory of an in-line inspection (ILI) tool to provide a more precise reference than time-based above-ground marker systems for the location of pipeline anomalies. The system consisted of 2 pairs of transmitter (TX) and receiving (RX) circuits working at low and varied frequencies. An additional module was installed in the front section of an ILI tool, which contained a frequency transmitter whose signals are transmitted through cabling to an external transmitter and retransmitted simultaneously to a receiver installed in the rear section of an additional module of the tool in order to guarantee that the signal recorded by the tool corresponded to the smart location system. The system was used to detect anomalies in a subsea pipeline near Rio de ...

2004-07-01

417

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal ...

2011-09-01

423

Therapeutic Approaches to the Treatment of Botulism  

Science.gov (United States)

... above. In the initial round of experiments, the venom of Dendroaspis augustepsis was tested for its actions on neuromuscular transmission. ...

1989-10-01

424

The urine test strip of the future.  

Science.gov (United States)

The aim of the classical multiple test strip is to perform routine chemical analysis in one single operation, yielding maximum diagnostic and prognostic information. A maximum of 10 test areas should not be exceeded. The efficiency of the currently marketed test strips is discussed and improvements within acceptable price limits are suggested. PMID:10841930

2000-07-01

427

Testing modern protective relays  

Energy Technology Data Exchange (ETDEWEB)

Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmission lines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.

1994-01-01

430

Teacher Professional Continuum  

Science.gov (United States)

... efforts in developing and testing prototype materials or tools and Full Development Projects to ...

431

THE EFFECT OF FIBRE MISALIGNMENT ON THE ...  

Science.gov (United States)

... and testing of unidirectional composites, there are serious doubts about the possibility of obtaining a true ultimate compressive strength for this kind ...

438

Radionuclides Migration Prevention  

International Science & Technology Center (ISTC)

Prevention of Radionuclide Migration from the Soil of Semipalatinsk Nuclear Test Site by Using of Interpolymer Complexes

439

Prenatal Care Visits  

Medline Plus

... a test for HIV, the virus that causes AIDS. Do a Pap smear to check for cervical ...

441

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

442

Model tests on a semi-axial pump turbine  

Energy Technology Data Exchange (ETDEWEB)

Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.

1984-03-01

443

Lupus  

Medline Plus

... diagnosed. A complete blood count (CBC), urinalysis, blood chemistries, and erythrocyte sedimentation rate (ESR) tests can provide ...

445

High Performance Electrical Modeling and Simulation Verification Test Suite - Tier I; TOPICAL  

International Nuclear Information System (INIS)

This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases.

2001-12-01

446

High Performance Electrical Modeling and Simulation Verification Test Suite - Tier I  

Science.gov (United States)

This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases.

2001-12-01

448

Even Better Mousetraps  

CERN Document Server

First test with new ASACUSA trap show promise for future antihydrogen beam experiments.

2007-01-01

450

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

451

Estimation of skin friction of pile shaft in remodeled clay  

Energy Technology Data Exchange (ETDEWEB)

Testing results obtained from simple shear and direct shear tests were conducted for investigating the frictional properties between steel pile shaft and silty clay in this paper. By using the analyzed results of these tests, a hyperbolic curve fitting method for estimating skin friction of pile shaft was proposed in which was verified by its application on the results of undrained uplift triaxial model pile tests.

1994-12-31

452

Environmental Economics  

Wastenet

environmental burden is studied by testing the Environmental Kuznets Curve hypothesis as well as application of statistical decomposition

453

Energy density ten times as high; Energy engineering: Zinc/air battery systems on trial. Dichte verzehnfacht; Energietechnik: Zink-Luft-Batteriesystem im Test  

Energy Technology Data Exchange (ETDEWEB)

Prior to an industrial-scale test of zinc/air batteries at Greven, the TUeV Bayern-Sachsen carried out preliminary tests on behalf of the Deutsche Bundespost. The results were quite promising: The energy density of the new battery is ten times as high as that of conventional lead batteries, and the battery-powered test vehicle had a range of up to 300 km. (orig.)

1994-01-01

454

Coated Superalloys for Power Installations  

International Science & Technology Center (ISTC)

Characterization and Testing of Coated Nickel- and Iron-Based Superalloys for Application in High-Temperature Power Installations

455

Chemical detection of leukocytes in urine by means of a new multiple test strip.  

Science.gov (United States)

The performance of the leukocyte test area of the new multiple urine test strip, Multistix-10-SG, was evaluated in both field trials and model experiments. The detection limit was found to be adequate for routine purposes. Unspecific reactions are rare and generally indicated by the results of the other test areas. PMID:3572312

1987-02-01

458

Americium 242m in nuclear test debris  

International Nuclear Information System (INIS)

... americium 241 americium 242 americium 243 curium 242 environment local

459

Accelerated aging speeds test of instrument reliability  

International Nuclear Information System (INIS)

Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.

1982-01-01

460

49 CFR 572.126 - Knees and knee impact test procedure.  

Science.gov (United States)

... 2010-10-01 false Knees and knee impact test procedure. 572.126 Section 572.126 Transportation...OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Six-year-old Child Test Dummy, Beta Version § 572.126 Knees...

2010-10-01

461

Well-test data from geothermal reservoirs  

Energy Technology Data Exchange (ETDEWEB)

Extensive well testing in geothermal resources has been carried out throughout the western United States and in northern Mexico since 1975. Each resource tested and each well test conducted by LBL during the eight-year period are covered in brief. The information, collected from published reports and memoranda, includes test particulars, special instrumentation, data interpretation when available, and plots of actual data. Brief geologic and hydrologic descriptions of the geothermal resources are also presented. The format is such that well test descriptions are grouped, in the order performed, into major sections according to resource, each section containing a short resource description followed by individual test details. Additional information regarding instrumentation is provided. Source documentation is provided throughout to facilitate access to further ...

1982-09-01

462

W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)  

Energy Technology Data Exchange (ETDEWEB)

Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.

1997-02-14

463

VIPEX (Vital-area Identification Package EXpert) Software Verification and Validation  

International Nuclear Information System (INIS)

The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: ? Testing basic functions including fault tree editing ? Testing all kind of functions ? Research for update from Visual BASIC 6.0 to Visual BASIC 2008

2003-12-01

464

Transient testing of FFTF fuel pins in TREAT  

International Nuclear Information System (INIS)

A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.

1986-09-07

465

To Beta Test, or Not to Beta Test: Is That the Question?  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The purpose of this paper is to help library technology staff understand the process of beta testing software, determine if it is appropriate for them to engage in the process, and provide suggestions on how to the time invested in the process. Design/methodology/approach - The paper explains what beta testing is, why it should be used and how to become a beta tester. Findings - The paper reveals that beta testing is not convenient for everyone, but those taking place in these activities should be thorough, positive and generous in order to maximize the return on investment in this kind of testing. Practical Implications - While beta testing new software features can take a significant amount of time, the resulting benefits of early access to new features and improved vendor-staf...

2008-01-01

466

The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests  

International Nuclear Information System (INIS)

A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.

1987-12-13

467

The PANDA tests for SBWR certification  

International Nuclear Information System (INIS)

The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of open-quotes passiveclose quotes ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests and extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient ...

1996-03-01

468

Safety analysis of FFTF loss of flow without scram tests  

International Nuclear Information System (INIS)

A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.

1987-06-07

469

A vibration amplification device for the seismic margins test of NPP equipment  

International Nuclear Information System (INIS)

This paper describes new test methodologies to obtain data used to evaluate the ultimate seismic strength of Nuclear Power Plant (NPP) equipment related to nuclear safety. The paper first reviews existing equipment seismic test data from the viewpoint of the evaluation of their ultimate seismic strength and/or seismic design margins, and extracts the issues in the existing data with regard to their applicability to the evaluation. Then, the paper proposes new test methodologies for the equipment to evaluate their ultimate seismic strength. The test methodology of the equipment employs a vibration amplification system to a shaking table and enhances its applicable maximum acceleration up to 6g. The test methodology herein is cost effective for obtaining test data that is indispensable for evaluating proper seismic margins of NPPs. (author)

2003-09-15

470

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio programme  

Energy Technology Data Exchange (ETDEWEB)

We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...

2004-07-01

471

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio programme  

International Nuclear Information System (INIS)

We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...

472

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio program.  

Energy Technology Data Exchange (ETDEWEB)

The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, multiphase ...

2004-08-01

473

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio program  

International Nuclear Information System (INIS)

The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, multiphase ...

474

A combined cycle engine test facility  

Energy Technology Data Exchange (ETDEWEB)

Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in ...

1995-09-01

475

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

476

TS-1 and TS-2 transient overpower tests on FFTF fuel  

International Nuclear Information System (INIS)

The TS-1 and TS-2 Transient Reactor Test Facility (TREAT) experiments were conducted on irradiated Fast Flux Test Facility (FFTF) fuel pins to characterize their failure behavior when subjected to hypothetical 5%/s transient overpower conditions. The TS-1 test employed a near-fresh (2 MWd/kg) fuel pin, while the TS-2 test used a medium-burnup (58 MWd/kg) fuel pin. Transient conditions were closely matched between the two experiments to provide a direct comparison of burnup effects on the failure response.

1985-11-10

477

Performance Testing Methodology for Safety-Critical Programmable Logic Controller  

International Nuclear Information System (INIS)

The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

2009-05-01

478

Intermediate scale borehole (Room C): In situ data report (January 1989--June 1993)  

Energy Technology Data Exchange (ETDEWEB)

Data are presented from the intermediate scale borehole test, an in situ test fielded in the pillar separating Rooms C1 and C2 at the Waste Isolation Pilot Plant (WIPP). The test was to provide data on the influence of scale, if any, on the structural behavior of underground openings in salt. These data include selected fielding information, test configuration, instrumentation activities, and comprehensive results from a large number of gages. Construction of the test began in December 1989, with the drilling of the intermediate scale borehole in December 1990. Gage data in this report cover the period from January 1989 through June 1993.

1994-11-01

479

DOE reports on feasibility of generic oil shale test facility  

Energy Technology Data Exchange (ETDEWEB)

In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.

1987-03-01

480

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

481

Amazon.com: The Art of Application Performance Testing: Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books  

Wastenet

...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Amazon.com:...The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Ian Molyneaux,The ...Art of Application Performance Testing : Help for Programmers and Quality Assurance,O'Reilly Media,0596520662,LA9780596520663,Computer Books: General,Application software,Computer software,...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books ...

482

Automated real-time testing (ARTT) for embedded control systems (ECS).  

Energy Technology Data Exchange (ETDEWEB)

Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS ...

2001-08-09

483

The Development of an Audio Computer-Based Classroom Test of ESL Listening Skills.  

Science.gov (United States)

There are very few examples of audio-based computerized tests, but for many disciplines, such as foreign language and music, there appear to be many benefits to this type of testing. The purpose of the present study was to develop and compare computer-delivered and audiocassette/paper-and-pencil versions of a listening test. The test was a measure of progress achievement of academic listening comprehension and vocabulary for high-intermediate level students of English as a Second Language (ESL) at a university-affiliated institute. The underlying assumption investigated was that the use of computer and audio technology for classroom progress tests would provide benefits of convenience and improved sound quality while providing measurement quality and validity that were at least comparable to the paper form of such tests. Results with 28 students indicate that ...

1999-04-01

484

Results of in-house cone-cup testing of low to high temperature SPF-alloys  

Energy Technology Data Exchange (ETDEWEB)

Material testing of SPF-sheet is usually done with coupon hot tensile testing. The optimum range of strain rates is determined with stepped strain tests. To overcome the problem of very few available testing facilities and time consuming and costly procedure, cone cup testing has been developed since long. This test can be generated directly in the workshop, no machining of samples is necessary and it is very much related to the real SPF-process. The analysis of suitable temperature and strain rate is done by simple measurement of resulting cone height. This paper describes a unique and novel variant of the above mentioned baseline design. It provides on-line data of the actual status of the cone cup forming resulting from the applied, constant pressure. Strain rate variations as a result from texture or from the alloy-related behaviour is detectable. Thinning ...

2004-07-01

485

FFTF [Fast Flux Test Facility] Integrated Leak Rate Test Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel ...

486

Design of a welltest for determining two-phase hydraulic properties  

Energy Technology Data Exchange (ETDEWEB)

This report describes the design of a well test to determine two-phase hydraulic properties of a low permeability, low porosity formation. Estimation of gas-related parameters in such formations is difficult using standard pumping tests mainly because of the strong fluctuations in the pressure and flow rate data which are a consequence of gas bubbles evolving in the test interval. Even more important is the fact that the data do not allow distinguishing among alternative conceptual models. The estimated parameters are therefore uncertain, highly correlated, and ambiguous. In this study we examine a test sequence that could be appended to a standard hydraulic testing program. It is shown that performing a series of water and gas injection tests significantly reduces parameter correlations, thus decreasing the estimation error. Moreover, the extended ...

1995-01-01

487

Constant extension rate (CERT) testing of alloy 690 and 800 nuclear steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT ...

1994-12-31

488

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. ...

1998-02-01

489

Research on pipe whip and jet under LOCA conditions, (2)  

International Nuclear Information System (INIS)

The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force increases in proportion to ...

490

Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions  

International Nuclear Information System (INIS)

Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The restraints were made of Type 304 ...

491

Results of the 1986 FFTF inherent safety tests  

International Nuclear Information System (INIS)

A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools.

1987-06-07

492

Products of motor burnout. Second quarterly technical report, October 1, 1994--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

The OSP (Operating Safety Procedure) required for performance of electrical arc testing of CFC replacement fluids was renewed. Electrical breakdown tests at one atmosphere pressure have been performed for R-22, R-134a, and R-125/R-143a (50:50 blend; R-507), and breakdown products identified. No differences in HCFC breakdown products are seen in the presence or absence of lubricant oils. The design of the high pressure-high temperature test stand has been finalized, and construction initiated during this quarter. Three motor stators and rotors were received from Tecumseh Products Company for use in motor burnout tests. A test plan for the motor breakdown tests is in preparation.

1995-01-15

493

Multi-centre evaluation of the urine test strip analyser Rapimat.  

Science.gov (United States)

A multi-centre evaluation of the test strip analyser, Rapimat, was performed by four laboratories following the ECCLS 2nd draft guidelines for the evaluation of analysers in clinical chemistry. Using the Rapignost urine test strip with the test fields for bilirubin, urobilinogen, acetoacetate, ascorbic acid, glucose, protein, nitrite, pH and haemoglobin, the Rapimat was found to be analytically reliable in comparison with other, in most cases quantitative procedures. During the observation period of about 6 months no breakdown occurred in any laboratory. Interferences and sensitivity as discussed for the bilirubin and urobilinogen test field are more related to the test strip than to the instrument. Several improvements for further developments are suggested. This multi-centre study has shown that the ECCLS protocol is applicable to analytical procedures leading to discrete results. ...

1985-08-01

494

In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings:  

British Library Electronic Table of Contents (United Kingdom)

Greenman J, Thorn RMS, Saad S, Austin AJ. In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings. Int Wound J 2006;3:322-329. Abstract The aim of this study was to develop an in vitro wound infection model that allows the comparison of the bacterial kill rate of antimicrobial wound dressings over the course of 3 days, with renewed microbial challenges each day, under realistic wound-like conditions. A test bed model of a moderately exuding wound was constructed from a hydrogel containing releasable foetal calf serum (FCS), and cellulose discs dosed with test microbes (Methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) suspended in 50% FCS applied at the interface between the test dressing and the hydrogel test bed. Freshly prep...

2006-01-01

495

FFTF operating experience, 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some ...

1984-04-09

496

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by ...

1981-10-01

497

Clinical and experimental studies of octocrylene's allergenic potency  

British Library Electronic Table of Contents (United Kingdom)

Background. Reports of positive patch test and photopatch test reactions to the chemical ultraviolet filter octocrylene have increased during the last decade. Little is known about the reason for octocrylene's allergenic activity. Objectives. To present and discuss the results of patch tests and photopatch tests with octocrylene, and to investigate the possible cause of its allergenic properties. Methods. Results of patch tests and photopatch tests with octocrylene in patients with adverse skin reactions to sunscreen products and/or ketoprofen were collected. The allergenic potency of octocrylene was investigated in the murine local lymph node assay (LLNA). Chemical reactivity assays were used to mimic octocrylene's interaction with biomolecules. Results. We report 23 cases of positive tes...

2011-01-01

498

Application of mass spectrometry to fuels and materials testing at FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 MW(th) sodium cooled reactor and is the largest test reactor of its type in the world. It was designed and is being operated to serve two purposes: gaining liquid metal system experience and serving as a test bed for fuels and materials. During test operations it is possible that cladding breaches and escape of fission gas to the reactor cover gas region can occur. To identify the source of such a leak all 78 fuel pin assemblies contain ''gas tag'' with a unique ''tag'' mixture in each assembly. The mass spectrometric identification of tag isotope ratios makes possible rapid location and thus faster removal (if required) of breached test pins.

499

Applicability of structural wall test results to seismic design of nuclear facilities  

International Nuclear Information System (INIS)

A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).