Energy Technology Data Exchange (ETDEWEB)
Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)
1996-10-01
Study of spatial resolution in three-dimensional rotational angiography
International Nuclear Information System (INIS)
In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone ...
2006-03-01
A DRAMATICALLY REDUCED SIZE IN THE GANTRY DESIGN FOR THE PROTON-CARBON THERAPY.
Energy Technology Data Exchange (ETDEWEB)
Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the ...
2006-06-23
New concept to optimize emergency diagnoses in patients with multiple injuries
International Nuclear Information System (INIS)
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
UK PubMed Central (United Kingdom)
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
2010-04-01
Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography
International Nuclear Information System (INIS)
Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).
1985-01-01
Cerebral angiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
1985-01-01
Angiography in dibuthylnitrosamine-induced rat bladder tumours
International Nuclear Information System (INIS)
(1972). Denmark Ekelund, L. Goethlin, J. Henrikson, H. Letter-to-the-
3D rotational angiography: Benefits obtained in clinical endovascular treatments
International Nuclear Information System (INIS)
The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3D images are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)
1999-01-01
Angiography of the head using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
1985-01-01
Aphakic macular oedema following prosthetic lens implantation.
UK PubMed Central (United Kingdom)
Fluorescein angiography of the iris was performed on patients with plastic lens implants with cystoid oedema of the macula, and the nature of the vascular changes was compared with controls provided...Full Text Available
1977-05-01
Transbrachial arterial digital subtraction angiography
International Nuclear Information System (INIS)
27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
1987-03-01
International Nuclear Information System (INIS)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
1987-01-01
Angiography in the diagnosis and treatment of trauma
Energy Technology Data Exchange (ETDEWEB)
Angiography plays a vital role in the investigation of the patient suffering from multiple trauma. The commonest injuries have been rupture of the thoracic aorta, renal lacerations, arterial bleeding associated with fractures and soft-tissue injuries to the pelvis, and occlusions of the arteries supplying the limbs. Transcatheter arterial embolization may be the definitive therapeutic procedure in pelvic bleeding.
1983-09-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for ...
Correlation of myocardial TC-99m-MIBI perfusion SPECT with coronary angiography in Namazi hospital
International Nuclear Information System (INIS)
Coronary heart disease is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of Coronary artery disease and is suggested by many investigators in recent years. In this study, 64 patients who had a Tc99m-MIBI SPECT myocardial perfusion study at our department, underwent coronary angiography within 4 months. Correlation of the methods revealed that SPECT Tc99m -MIBI had a high sensitivity and specificity in our hand, which is comparable with international findings.
2004-04-27
Energy Technology Data Exchange (ETDEWEB)
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
1992-08-01
UK PubMed Central (United Kingdom)
BackgroundPatients with ST-elevation myocardial infarction (STEMI) treated with fibrinolysis are increasingly, and ever earlier, referred for routine coronary angiography and where...Full Text Available
UK PubMed Central (United Kingdom)
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
2009-07-01
UK PubMed Central (United Kingdom)
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
2011-02-01
UK PubMed Central (United Kingdom)
Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available
2001-12-01
Angina with a normal coronary angiogram caused by amyloidosis
UK PubMed Central (United Kingdom)
A case of severe intractable angina pectoris with normal angiography is presented. Following video assisted thoracic sympathectomy the patient died of heart failure. Microvascular cardiac amyloidosis...Full Text Available
2004-09-01
Non-selective cervical and cerebral three-dimensional rotational angiography
International Nuclear Information System (INIS)
To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further ...
2007-09-01
Digital subtraction angiography with scanning lazer stimulated luminescence
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-10-01
International Nuclear Information System (INIS)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography ...
1994-01-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and ...
1999-03-01
International Nuclear Information System (INIS)
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
British Library Electronic Table of Contents (United Kingdom)
Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can ...
2003-07-01
Medical explorations by radioisotopes in Lebanon
International Nuclear Information System (INIS)
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
Hepatocellular carcinoma: recent advances in diagnosis with iodized oil
Energy Technology Data Exchange (ETDEWEB)
This opinion presents an overview of recent developments in the diagnosis and treatment of hepatocellular carcinoma (HCC) in Japan. The use of Ethiodol (iodized ethyl ester of the fatty acid of poppyseed oil) for hepatic angiography in diagnosing and treating (combined with chemotherapeutic agents) HCC has been reported. Ethiodol has been found to localize in HCC and remain there for long periods. The implications of these findings are discussed.
1985-01-01
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue contrast and reduced ...
2007-03-01
New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
Energy Technology Data Exchange (ETDEWEB)
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC ...
2008-04-15
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of the coefficient of ...
2002-06-01
Combining anatomy and function: the path to true image fusion
Energy Technology Data Exchange (ETDEWEB)
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical ...
2001-10-01
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...
2008-02-21
International Nuclear Information System (INIS)
Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the ...
2007-11-01
MRI with pathogenic correlation of small renal cell carcinoma
Energy Technology Data Exchange (ETDEWEB)
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which showed low signal intensity of T2-weighted ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level localized the pathology in the transverse plane and greatly aided in ...
1984-09-01
Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube
International Nuclear Information System (INIS)
This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...
1985-04-25
Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification
International Nuclear Information System (INIS)
Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph ...
1998-08-01
Computed tomography (CT) in renal trauma
International Nuclear Information System (INIS)
CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as renal infarction, ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence tomography are the ...
2009-07-01
International Nuclear Information System (INIS)
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
2011-01-01
A computer-assisted method for 3D subtraction angiography based on spiral CT
International Nuclear Information System (INIS)
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the ...
Radiodiagnosis of Ewing's sarcoma of the rib in children
International Nuclear Information System (INIS)
The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
International Nuclear Information System (INIS)
Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear ...
1985-06-02
Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography
International Nuclear Information System (INIS)
The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased ...
2001-09-01
The helical tomotherapy thread effect
International Nuclear Information System (INIS)
Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the off-axis dose profiles which differ from the axial profiles as well as a long scatter tail ...
2005-05-01
Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine
International Nuclear Information System (INIS)
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning size, position and ...
1995-10-01
International Nuclear Information System (INIS)
The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total biological response rate is 42% (n= 41) for the ...
2006-12-15
The value of cardiac catheterization and cineangiography in infantile lobar emphysema
International Nuclear Information System (INIS)
Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).
Targeted drug delivery under MRI guidance
British Library Electronic Table of Contents (United Kingdom)
The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...
2008-01-01
Prenatal diagnosis and perinatal management of left coronary artery to right atrium fistula.
Serious complications due to coronary artery fistulae have been described. Most authors recommend early intervention at the time of diagnosis. We present a case of a fistula originating from a dilated left coronary artery and draining into the right atrium, which was diagnosed prenatally by color Doppler echocardiography. During pregnancy, the echocardiographic findings remained unchanged, and there were no signs of heart failure. After birth, the fistula was confirmed by angiography. Additionally, a persistent left superior vena cava draining into the coronary sinus and a very small ventricular septal defect were detected. The fistula was closed successfully by transcatheter coil embolization. At 17 months old the child was in good clinical condition. Prenatal diagnosis of coronary artery fistulae may be possible and may improve perinatal management and outcome. PMID:12047543
2002-06-01
International Nuclear Information System (INIS)
Iopentol (350 mg I/ml) has been compared with iohixol (350 mg I/ml) in a double-blind randomized parallel group trial with 32 and 35 patients receiving iopentol and iohexol, respectively. Coronary angiography and left ventriculography were performed, and the mean total volume injected was 124 ml of iopentol and 135 ml of iohexol . There were no statistically significant differences regarding changes in heart rate and frequency of adverse advents, which were the primary parameters, between the two groups of patients. Blood pressure and ECG parameters revealed only minor fluctuations which were of no clinical relevance. The visualization of the coronary arteries and the left ventricle were the same with both contrast media, as was the diagnostic quality. The results support the use of iopentol in cardioangiography. (author). 1 ref.; 5 tabs.
International Nuclear Information System (INIS)
Rotatostereoradiographic (RSRG) images are displayed in an oscillating, rotational manner. While reviewing these rotating images, the radiologist may become psychologically irritated by the rotation. A rapidly rotating display of linear subjects gives one three-dimensional depth information. This three-dimensional sense is lost if the rotation speed is too slow. The authors of this paper determined the slowest possible rotating display speed that allows perception of three-dimensional depth information minimizing psychological irritation. In the RSRG device (Shimadzu ROTATO-360), an x-ray tube coupled with an image intensifier rotates through a 180 degrees arc in 1.8 or 2.25 seconds. Both rotation times could be doubled. The images were displayed at four different speeds, covering the 180 degrees arc in 1.8, 2.25, 3.6, and 4.5 seconds.
1990-11-25
CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia
International Nuclear Information System (INIS)
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.
1999-04-01
International Nuclear Information System (INIS)
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
A method of stereotaxic localization adopted for conventional and digital radiography
International Nuclear Information System (INIS)
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or diagnostic ...
1986-01-01
International Nuclear Information System (INIS)
Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the 70% stenosis was used ...
2006-09-01
International Nuclear Information System (INIS)
Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. Results: All parameters were found to have an ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis ...
2002-11-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Energy Technology Data Exchange (ETDEWEB)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression ...
2003-12-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
International Nuclear Information System (INIS)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The ...
2003-12-01
Energy Technology Data Exchange (ETDEWEB)
In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in seltenen Faellen eine ...
1995-11-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
1989-06-01
International Nuclear Information System (INIS)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
1989-01-01
Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January through December 1984 ...
1984-12-01
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and 33.3%, respectively) in ...
2000-10-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the intracranial arteries, unenhanced TOF MRA ...
2004-11-01
Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy
Energy Technology Data Exchange (ETDEWEB)
In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in apical and inferior region and [sup ...
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computed tomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive findings. (author)
1997-10-01
Localization of abnormal parathyroid glands using thallium-201
Ectopically located parathyroid adenomas may be difficult to find during initial neck exploration. They account for over 70 percent of missed adenomas found at reexploration. Preoperative localization of parathyroid adenomas would reduce unnecessary dissection and possibly reduce the number of negative results of initial neck exploration. Before reoperative parathyroid surgery is performed, some means of localization is mandatory to detect ectopic adenomas in the neck and mediastinum. Computed tomography and ultrasonography cannot effectively evaluate the mediastinum. Angiography and venous parathyroid hormone sampling are invasive, costly, and tedious to perform. We have shown that thallium-201 will accurately localize ectopic parathyroid adenomas. All 10 adenomas found in positions not immediately adjacent to the thyroid gland were detected by thallium-201 scintigraphy. One was a mediastinal adenoma resected with a median sternotomy. Our results suggest that ...
1984-07-01
Energy Technology Data Exchange (ETDEWEB)
Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to conventional CT in detecting small, daughter ...
1989-12-15
International Nuclear Information System (INIS)
Purpose. To evaluate injection-associated pain, safety, and efficacy with the isotonic contrast medium iodixanol (Visipaque 270 mg I/ml) compared with iopromide (Ultravist 300 mg I/ml) in femoral arteriography. Methods. A multicenter, double-blind, randomized, parallel-group clinical investigation was carried out in 54 hospitals in Europe. Of the patients evaluated, 1225 received iodixanol and 1227 iopromide in conventional and/or digital subtraction angiography. Results. The iodixanol group reported statistically significantly less injection-associated pain (0.9%) than the iopromide group (9.5%) (p<0.001). Further, 4.1% in the iodixanol group experienced pain and/or severe heat sensation vs 19.8% in the iopromide group (p<0.001). In the iodixanol group, 1.8% of the patients experienced contrast-related adverse events vs 2.4% in the iopromide group (p=NS). Overall diagnostic information was optimal for 94.1% in the iodixanol group and 95.3% in the iopromide ...
1997-07-01
Diagnosis for the cancer extension of cholangiocarcinoma. The current status
International Nuclear Information System (INIS)
Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...
2010-07-01
International Nuclear Information System (INIS)
We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ventricular wall thickness ...
Computer assisted axial tomography (Emi scan) in neurologic investigation
Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...
1974-01-01
What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?
International Nuclear Information System (INIS)
Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant differences in coronary artery ...
2010-08-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on ...
2009-01-01
The role of interventional radiology in management of patients with end-stage renal disease
Energy Technology Data Exchange (ETDEWEB)
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 patients. The exact anatomy ...
2002-12-01
64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization ...
2006-04-15
International Nuclear Information System (INIS)
The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; 0.6%), and renal vein thrombosis (n = 7; 0.5%). ...
Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors
Energy Technology Data Exchange (ETDEWEB)
Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The concordance rate between the pathological diagnosis during and after the operation was 67%. ...
2001-04-01
International Nuclear Information System (INIS)
The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input values for the ANN. The ...
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...
2011-04-15
International Nuclear Information System (INIS)
To evaluate the radiological patterns of vascular invasion in peripheral cholangiocarcinomas. Hepatic arteriography and portography in 20 cases with cholangiocarcinoma including 12 cases with angiographic CT were retrospectively analyzed. The arteriography showed no arterioportal shunt, hypertrophy of tumor vessel, or tumor staining extending to central portion of the mass in all cases. However, doughnut shaped peripheral tumor staining was seen until late hepatogram phase in 12 cases and compensatory hyperperfusion around the mass was seen in six cases (eight cases if include arterial CT). Encasement of tumor vessel was seen in 12 cases, and hypertrophy of feeding vessel in nine cases. On portography, the filling defect on segmental portal branch could be demonstrated only in 11 cases. Shape of the portal defect was tapered narrowing in six cases, abrupt narrowing in two cases but intraluminal nodular filling defect was not seen. Remaining three cases were difficult to define the ...
1995-01-01
Multidetector-row helical CT: analysis of time management and workflow
International Nuclear Information System (INIS)
The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, ...
2002-03-01
International Nuclear Information System (INIS)
The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them ...
Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent ...
2003-04-01
Energy Technology Data Exchange (ETDEWEB)
Hemodynamic characteristics were studied by using in vivo vascular imaging techniques in 17 resected early stage hepatocellular carcinoma (e-HCC) by comparing them with 49 resected advanced HCCs (ad-HCC) less than 3 cm in diameter. In this study, e-HCC was defined as the nodule being uniformly composed of well-differentiated HCC or adenomatous hyperplastic nodule containing well-differentiated HCC foci within the nodule. In vivo vascular imaging techniques are as follows; US angiography with intraarterial CO{sub 2} microbubbles were performed to assess the tumor arterial vascularity, and CT during arterial portography (CTAP) was performed to assess the portal perfusion within the nodule. Of 17 e-HCC nodules 5 were hypervascular, 5 were isovascular, 4 were hypovascular, and 3 were vascular spot in hypovascular pattern in contrast to 49 ad-HCC nodules, 43 of which were hypervascular and 6 were isovascular. Of 14 e-HCCs, 9 nodules showed perfusion defect and 5 did not ...
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess the effect of adenosine-triphosphate (ATP) on hemodynamics and left ventricular (LV) function, and to examine the value of ATP radionuclide-ventriculography (RNVG) for detecting coronary artery disease (CAD) in comparison with standard exercise RNVG. Thirty-eight consecutive patients with suspected CAD underwent ATP (0.18 mg/Kg/min) RNVG and symptom-limited exercise RNVG. Coronary angiography revealed 27 patients with CAD (Group S) and 11 without CAD (Group N). In group S, exercise induced an increase in LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV), and a decrease in LV ejection fraction (LVEF). In contrast, ATP infusion caused LVESV to decrease in both groups, improving LVEF. Only 14 of 39 segments whose wall motion was deteriorated by exercise showed worsening regional wall motion during ATP infusion. The sensitivity and specificity of ATP RNVG for detecting CAD were 22. 2% and 100%, while those of ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il notevole ...
1999-04-01
Helical CT defecography; La defecografia con Tomografia Computerizzata spirale
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to ...
1998-03-01
Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings
International Nuclear Information System (INIS)
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT ...
2000-12-01
Aortic non communicating dissections. A study with helical CT
International Nuclear Information System (INIS)
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those seen on DSA images. The ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic coating and the ...
2001-02-01
Energy Technology Data Exchange (ETDEWEB)
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed tomography (SPECT) ...
2003-12-01
Energy Technology Data Exchange (ETDEWEB)
CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography technique. The reanimator was always presented to monitor the patients' vital functions and ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT ...
2000-12-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
