WorldWideScience

Sample records for blood plasma clinical-chemical

  1. Rapid separation of bacteria from blood - Chemical aspects.

    Science.gov (United States)

    Alizadeh, Mahsa; Wood, Ryan L; Buchanan, Clara M; Bledsoe, Colin G; Wood, Madison E; McClellan, Daniel S; Blanco, Rae; Ravsten, Tanner V; Husseini, Ghaleb A; Hickey, Caroline L; Robison, Richard A; Pitt, William G

    2017-06-01

    To rapidly diagnose infectious organisms causing blood sepsis, bacteria must be rapidly separated from blood, a very difficult process considering that concentrations of bacteria are many orders of magnitude lower than concentrations of blood cells. We have successfully separated bacteria from red and white blood cells using a sedimentation process in which the separation is driven by differences in density and size. Seven mL of whole human blood spiked with bacteria is placed in a 12-cm hollow disk and spun at 3000rpm for 1min. The red and white cells sediment more than 30-fold faster than bacteria, leaving much of the bacteria in the plasma. When the disk is slowly decelerated, the plasma flows to a collection site and the red and white cells are trapped in the disk. Analysis of the recovered plasma shows that about 36% of the bacteria is recovered in the plasma. The plasma is not perfectly clear of red blood cells, but about 94% have been removed. This paper describes the effects of various chemical aspects of this process, including the influence of anticoagulant chemistry on the separation efficiency and the use of wetting agents and platelet aggregators that may influence the bacterial recovery. In a clinical scenario, the recovered bacteria can be subsequently analyzed to determine their species and resistance to various antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effects of the addition of blood plasma proteins on physico-chemical properties of emulsion-type pork sausage during cold storage.

    Science.gov (United States)

    Kim, Sungho; Jin, Sangkeun; Choi, Jungseok

    2017-10-01

    Most slaughter blood is discarded, resulting in problems related to costs for wastewater disposal and environmental pollution. However, animal blood contains various proteins such as albumin, globulin and globin and can be used as a natural emulsifier, stabiliser and colour additive. Thus, this study was carried out to investigate the effect of blood plasma proteins on the physico-chemical properties of emulsion-type pork sausages stored at 4°C over 5 weeks. The emulsion-type pork sausages with plasma powders had higher pH than the other treatments during week 5, and higher shear force than the control (P binder for the production of excellent meat products compared to other binders. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  3. [Distribution of chemical elements in whole blood and plasma].

    Science.gov (United States)

    Barashkov, G K; Zaĭtseva, L I; Kondakhchan, M A; Konstantinova, E A

    2003-01-01

    The distribution factor (Fd) of 35 elements of plasma and whole blood in 26 healthy men and women was detected by ICP-OES. Usilig this parameter the elements were subdivided in 3 pools. 9 of them have Fd higher than 1.5 ("elements of plasma"-Ag, Ca, Cu, In, Li, Na, Se, Si, Sr); 6 have lower than 0.5 ("elements of blood cells"-Fe, K, Mn, Ni, V, Zn), other 20-about 1 ("blood elements"). Fd of all elements depends on ionic radius. Elements of 2nd sub-groups of all groups of Mendeleev's periodic table ("heavy metals") depend on the similar law: "with growing of ionic radius the concentration of elements in plasma enhances". In alkaline metals Fd depends on the opposite law:" with growing of ionic radius of alkaline metal the quantity of elements in blood cells enhance". Dependence of Fd on the value of atomic mass in periods or in exterior electronic cloud (s-, p-, d-, f-) was not established. The table of distribution of all detected elements in whole blood in relation to 8 macroelements (Ca, Mg, K, Na, S, P, Fe, Zn,) is presented, as a basic diagnostic criteria in metal-ligand homeostasis disturbance.

  4. Clinical value of indicators of cationic proteins, leukocytes myeloperoxidase and fibronectin blood plasma in viral meningitis in children

    Directory of Open Access Journals (Sweden)

    O. G. Kimirilova

    2017-01-01

    Full Text Available Objective: was to establish clinical and diagnostic value of cytochemical indices of peripheral blood leukocytes (cationic protein and myeloperoxidase, fibronectin blood plasma to assess the severity, predict the course and outcome of viral meningitis in children.Subjects and methods. In 450 patients with viral meningitis (enterovirus, arbovirus, parotitic, herpesviral, adenovirus etiology at the age of 14 years, the parameters of the microbicidal system of leukocytes (cation proteins, myeloperoxidase and fibronectin blood plasma were determined. Etiological diagnosis of meningitis was confirmed by release of viral RNA from blood and cerebrospinal fluid by the polymerase chain reaction, enzyme-linked immunosorbent assay (ELISA.The results and conclusion. Found that severe, prolonged duration, lethal outcome of viral meningitis in children are accompanied by sugnificant suppression of cationic proteins, myeloperoxidase, fibronectin blood plasma, maximally expressed in lethal outcomes, compared with the severe form, but with a favorable outcome and control. Settings imbalance cationic proteins, myeloperoxidase, fibronectin blood plasma are objective criteria of the adaptation syndrome that reflects the state of the phagocytosis system in viral meningitis in children and can be considered as additional criteria for predicting the course and outcome of disease.

  5. Clinical symptoms in fibromyalgia are better associated to lipid peroxidation levels in blood mononuclear cells rather than in plasma.

    Science.gov (United States)

    Cordero, Mario D; Alcocer-Gómez, Elísabet; Cano-García, Francisco J; De Miguel, Manuel; Carrión, Angel M; Navas, Plácido; Sánchez Alcázar, José A

    2011-01-01

    We examined lipid peroxidation (LPO) in blood mononuclear cells (BMCs) and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM) patients. We conducted a case-control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ), visual analogues scales (VAS), and the Beck Depression Inventory (BDI). Oxidative stress was determined by measuring LPO in BMCs and plasma. We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (PBMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores). The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM.

  6. Relationships between organohalogen contaminants and blood plasma clinical-chemical parameters in chicks of three raptor species from Northern Norway

    DEFF Research Database (Denmark)

    Sonne, Christian; Bustnes, Jan Ove; Herzke, Dorte

    2010-01-01

    :creatinine were significantly positively correlated to various OHCs (all: praptor chicks of Northern Scandinavia may impact blood plasma biochemistry in a way that indicates impacts on liver, kidney, bone...

  7. Blood plasma clinical-chemical parameters as biomarker endpoints for organohalogen contaminant exposure in Norwegian raptor nestlings

    DEFF Research Database (Denmark)

    Sonne, Christian; Bustnes, Jan O.; Herzke, Dorte

    2012-01-01

    Raptors are exposed to biomagnifying and toxic organohalogenated compounds (OHCs) such as organochlorines, brominated flame retardants and perfluorinated compounds. To investigate how OHC exposure may affect biochemical pathways we collected blood plasma from Norwegian northern goshawk (n=56...... it is uncertain if such changes have any health effects. The OHC concentrations were below concentrations causing reproductive toxicity in adults of other raptor species but similar to those of concern for endocrine disruption of thyroid hormones in e.g., bald eagles....

  8. Prehospital use of plasma: the blood bankers' perspective.

    Science.gov (United States)

    Hervig, Tor; Doughty, Heidi; Ness, Paul; Badloe, John F; Berseus, Olle; Glassberg, Elon; Heier, Hans E

    2014-05-01

    At the 2013 Traumatic Hemostasis and Oxygenation Research Network's Remote Damage Control Resuscitation symposium, a panel of senior blood bankers with both civilian and military background was invited to discuss their willingness and ability to supply prehospital plasma for resuscitation of massively bleeding casualties and to comment on the optimal preparations for such situations. Available evidence indicates that prehospital use of plasma may improve remote damage control resuscitation, although level I evidence is lacking. This practice is well established in several military services and is also being introduced in civilian settings. There are few, if any, clinical contraindications to the prehospital use of plasma, except for blood group incompatibility and the danger of transfusion-induced acute lung injury, which can be circumvented in various ways. However, the choice of plasma source, plasma preparation, and logistics including stock management require consideration. Staff training should include hemovigilance and traceability as well as recognition and management of eventual adverse effects. Prehospital use of plasma should occur within the framework of clinical algorithms and prospective clinical studies. Clinicians have an ethical responsibility to both patients and donors; therefore, the introduction of new clinical capabilities of transfusion must be safe, efficacious, and sustainable. The panel agreed that although these problems need further attention and scientific studies, now is the time for both military and civilian transfusion systems to prepare for prehospital use of plasma in massively bleeding casualties.

  9. [Clinical use of virally inactived plasma. The experience of Blood Transfusion Unit in Mantova, Italy].

    Science.gov (United States)

    Lepri, Debora; Capuzzo, Enrico; Mattioli, Anna Vittoria; Dall'Oglio, Daniela; Sgarioto, Vincenzo; Terenziani, Isabella; Caramaschi, Giacomo; Manzato, Franco; Franchini, Massimo

    2013-03-01

    Fresh Frozen Plasma (FFP) is a blood component whose clinical use is widespread worldwide. Transfusion safety of this product is ensured by legally obligatory tests. Although these tests are carried out on each plasma donation, safety levels can be further improved by using some technical procedures, such as, among others, methylene blue (MB) and solvent-detergent (SD) viral inactivation methods. The DMTE (Blood Transfusion Unit) in Mantova has used the pharmaceutical-like SD virally inactivated plasma since 2007 (Plasmasafe, Kedrion) as replacement of the PFC by each single donor. Guidelines for the usage of both products are the same. With the main aim of assessing the therapeutic effectiveness and safety of Plasmasafe, we decided to clinically monitor transfusions performed with this product on patients of the Intensive Care Unit at the city hospital in Mantova. In addition, we controlled some coagulation parameters (PT, aPTT, ATIII, Fibrinogen, PC, PS, FV, FVII, FVIII) before and 24 hours after the Plasmasafe infusion. From a clinical point of view, the use of Plasmasafe always led to a significant reduction, or complete stop, of the bleeding. No transfusion-related adverse events were recorded. As regards, the most relevant laboratory results, a marked increase in the above mentioned hemostatic parameters was detected. Furthermore, patients transfused with this product received a mean volume significantly lower than an historical cohort of patients treated with FFP (503 mL with Plasmasafe versus 1549 mL with FFP, Pcost-effective treatment, able to rapidly correct hemostatic abnormalities, for critical patients.

  10. [Ratio of erythrocyte and plasma in massive blood transfusion].

    Science.gov (United States)

    Wen, Xian-Hui; Liu, Feng-Xia; Zhang, Jun-Hua; Gui, Rong

    2014-06-01

    This study was purposed to explore the suitable ratio between fresh frozen plasma and erythrocyte by retrospective analysis of coagulation in patients with massive blood transfusion. The clinical data of 151 cases with massive blood transfusion from January 2011 to January 2013 were analyzed retrospectively. According to coagulation, patients were divided into coagulation normal group (138 cases) and coagulation dysfunction group (13 cases). Based on the ratio of 1:1 of fresh frozen plasma and erythrocyte, the patients were divided into high plasma group(2:1), medium plasma group (1:1) and low plasma (blood transfusion. The results showed that prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) were prolonged, fibrinogen (FIB) level decreased significantly (all P blood transfusion 24 h; the high plasma and the medium plasma group of coagulation normal group had no significant changes in coagulation (P > 0.05); prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen level in the medium plasma and low plasma subgroup of coagulation dysfunction group after massive transfusion was still in abnormal levels (P > 0.05), coagulation function in high plasma subgroup was improved significantly (P blood transfusion, the ratio between fresh frozen plasma and erythrocyte is recommended to be 2:1 in patients of coagulation dysfunction in order to improve the patient's coagulation function and to reduce the incidence of adverse event, the ratio of fresh frozen plasma to erythrocyte is recommended to be 1:1 in patients with normal coagulation so as to reduce the dilutional coagulopathy and hypervolemia of blood.

  11. [Classification of results of studying blood plasma with laser correlation spectroscopy based on semiotics of preclinical and clinical states].

    Science.gov (United States)

    Ternovoĭ, K S; Kryzhanovskiĭ, G N; Musiĭchuk, Iu I; Noskin, L A; Klopov, N V; Noskin, V A; Starodub, N F

    1998-01-01

    The usage of laser correlation spectroscopy for verification of preclinical and clinical states is substantiated. Developed "semiotic" classifier for solving the problems of preclinical and clinical states is presented. The substantiation of biological algorithms as well as the mathematical support and software for the proposed classifier for the data of laser correlation spectroscopy of blood plasma are presented.

  12. Plasma concentrations of endothelial vasoactive substances in clinically healthy subjects. associations with urinary albumin excretion and ambulatory blood pressure

    DEFF Research Database (Denmark)

    Clausen, P; Jensen, J S; Jensent, G

    2000-01-01

    controls with normoalbuminuria. Plasma concentration of ET-1 was measured using an ELISA method and plasma concentration of nitrate/nitrite using a photometric method. Twenty-four-hour blood pressure was measured using a portable recorder (TM-2421). No significant differences in the concentrations...... of nitrate/nitrite and ET-1 were found between the groups, e.g. 21 (10-105) vs. 18 (11 -152) (p=0.33) and 0.98 (0.58 1.95) vs. 1.10 (0.54 -1.50) (p = 0.27), respectively. However, plasma nitrate/nitrite was significantly positively correlated to systolic and diastolic blood pressure in subjects...... in clinically healthy subjects. However, nitrate/nitrite is positively correlated to BP only in subjects with normoalbuminuria, and ET-1 is positively correlated to BP only in subjects with elevated UAE....

  13. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  14. Blood plasma lipidomic signature of epicardial fat in healthy obese women.

    Science.gov (United States)

    Scherer, Max; Montoliu, Ivan; Qanadli, Salah D; Collino, Sebastiano; Rezzi, Serge; Kussmann, Martin; Giusti, Vittorio; Martin, François-Pierre J

    2015-01-01

    A lipidomic approach was employed in a clinically well-defined cohort of healthy obese women to explore blood lipidome phenotype ascribed to body fat deposition, with emphasis on epicardial adipose tissue (EAT). The present investigation delivered a lipidomics signature of epicardial adiposity under healthy clinical conditions using a cohort of 40 obese females (age: 25-45 years, BMI: 28-40 kg/m(2) ) not showing any metabolic disease traits. Lipidomics analysis of blood plasma was employed in combination with in vivo quantitation of mediastinal fat depots by computerized tomography. All cardiac fat depots correlated to indicators of hepatic dysfunctions (ALAT and ASAT), which describe physiological connections between hepatic and cardiac steatosis. Plasma lipidomics encompassed overall levels of lipid classes, fatty acid profiles, and individual lipid species. EAT and visceral fat associated with diacylglycerols (DAG), triglycerides, and distinct phospholipid and sphingolipid species. A pattern of DAG and phosphoglycerols was specific to EAT. Human blood plasma lipidomics appears to be a promising clinical and potentially diagnostic readout for patient stratification and monitoring. Association of blood lipidomics signature to regio-specific mediastinal and visceral adiposity under healthy clinical conditions may help provide more biological insights into obese patient stratification for cardiovascular disease risks. © 2014 The Obesity Society.

  15. The feed gas composition determines the degree of physical plasma-induced platelet activation for blood coagulation

    Science.gov (United States)

    Bekeschus, Sander; Brüggemeier, Janik; Hackbarth, Christine; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Partecke, Lars-Ivo; van der Linde, Julia

    2018-03-01

    Cold atmospheric (physical) plasma has long been suggested to be a useful tool for blood coagulation. However, the clinical applicability of this approach has not been addressed sufficiently. We have previously demonstrated the ability of a clinically accepted atmospheric pressure argon plasma jet (kINPen® MED) to coagulate liver incisions in mice with similar performance compared to the gold standard electrocauterization. We could show that plasma-mediated blood coagulation was dependent on platelet activation. In the present work, we extended on this by investigating kINPen®-mediated platelet activation in anticoagulated human donor blood ex vivo. With focus on establishing high-throughput, multi-parametric platelet activation assays and performing argon feed gas parameter studies we achieved the following results: (i) plasma activated platelets in heparinized but not in EDTA-anticoagulated blood; (ii) plasma decreased total platelet counts but increased numbers of microparticles; (iii) plasma elevated the expression of several surface activation markers on platelets (CD62P, CD63, CD69, and CD41/61); (iv) in platelet activation, wet and dry argon plasma outperformed feed gas admixtures with oxygen and/or nitrogen; (v) plasma-mediated platelet activation was accompanied by platelet aggregation. Platelet aggregation is a necessary requirement for blood clot formation. These findings are important to further elucidate molecular details and clinical feasibility of cold physical plasma-mediated blood coagulation.

  16. Clinical Symptoms in Fibromyalgia Are Better Associated to Lipid Peroxidation Levels in Blood Mononuclear Cells Rather than in Plasma

    Science.gov (United States)

    Cano-García, Francisco J.; De Miguel, Manuel; Carrión, Angel M.; Navas, Plácido; Sánchez Alcázar, José A.

    2011-01-01

    Background We examined lipid peroxidation (LPO) in blood mononuclear cells (BMCs) and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM) patients. Methods We conducted a case–control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ), visual analogues scales (VAS), and the Beck Depression Inventory (BDI). Oxidative stress was determined by measuring LPO in BMCs and plasma. Results We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (P<0.001). A significant correlation between LPO in BMCs and clinical parameters was observed (r = 0.584, P<0.001 for VAS; r = 0.823, P<0.001 for FIQ total score; and r = 0.875, P<0.01 for depression in the BDI). We also found a positive correlation between LPO in plasma and clinical symptoms (r = 0.452, P<0.001 for VAS; r = 0.578, P<0.001 for FIQ total score; and r = 0.579, P<0.001 for depression in the BDI). Partial correlation analysis controlling for age and BMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores). Discussion The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM. PMID:22046409

  17. Clinical symptoms in fibromyalgia are better associated to lipid peroxidation levels in blood mononuclear cells rather than in plasma.

    Directory of Open Access Journals (Sweden)

    Mario D Cordero

    Full Text Available BACKGROUND: We examined lipid peroxidation (LPO in blood mononuclear cells (BMCs and plasma, as a marker of oxidative damage, and its association to clinical symptoms in Fibromyalgia (FM patients. METHODS: We conducted a case-control and correlational study comparing 65 patients and 45 healthy controls. Clinical parameters were evaluated using the Fibromyalgia Impact Questionnaire (FIQ, visual analogues scales (VAS, and the Beck Depression Inventory (BDI. Oxidative stress was determined by measuring LPO in BMCs and plasma. RESULTS: We found increased LPO levels in BMCs and plasma from FM patients as compared to normal control (P<0.001. A significant correlation between LPO in BMCs and clinical parameters was observed (r = 0.584, P<0.001 for VAS; r = 0.823, P<0.001 for FIQ total score; and r = 0.875, P<0.01 for depression in the BDI. We also found a positive correlation between LPO in plasma and clinical symptoms (r = 0.452, P<0.001 for VAS; r = 0.578, P<0.001 for FIQ total score; and r = 0.579, P<0.001 for depression in the BDI. Partial correlation analysis controlling for age and BMI, and sex, showed that both LPO in cells and plasma were independently associated to clinical symptoms. However, LPO in cells, but not LPO in plasma, was independently associated to clinical symptoms when controlling for depression (BDI scores. DISCUSSION: The results of this study suggest a role for oxidative stress in the pathophysiology of fibromyalgia and that LPO in BMCs rather than LPO in plasma is better associated to clinical symptoms in FM.

  18. Lipid spectrum of the newborn rats' blood at the radioactive and chemical effects in the prenatal period

    International Nuclear Information System (INIS)

    Buzan, Kh.

    1998-01-01

    The radioactive and chemical factors used in complex or separately during the prenatal period in the experiment induce ambiguous effects on the lipid metabolism in blood plasma and erythrocytes of newborn rats. The chemicals cause more significant changes in the blood plasma lipid metabolism than the radioactive irradiation does. Being used combined the radioactive and chemical factors do not increase each other's effect- their effects have opposite directions. The radiochemical exposure induce more significant shifts in the lipid spectrum in erythrocytic membranes than the separate factors

  19. Blood compatibility of gas plasma-treated diamond-like carbon surface-Effect of physicochemical properties of DLC surface on blood compatibility

    International Nuclear Information System (INIS)

    Mochizuki, Akira; Ogawa, Tatsuhisa; Okamoto, Keishi; Nakatani, Tatsuyuki; Nitta, Yuki

    2011-01-01

    From the knowledge that zwitterion-type polymers show good blood compatibility, the introduction of both cationic and anionic functional groups onto diamond-like carbon (DLC) surface is expected to improve blood compatibility. Thus, DLC films were treated with oxygen and ammonia gas plasmas. The surfaces were characterized in terms of chemical composition by XPS, contact angle, and zeta potential. XPS analysis showed the introductions of a carboxyl group by oxygen plasma treatment and nitrogen atoms by ammonia plasma treatment. The evaluation of blood compatibility for the DLC surfaces was carried out in terms of platelets and the coagulation system. Excellent improvement of platelet compatibility was observed by the treatment with the gas plasmas, regardless of the plasma species. As for the compatibility with the coagulation system, DLC surfaces with a high concentration of carboxyl groups (COOH) markedly activated the system via the intrinsic pathway. However, the surfaces treated with ammonia plasma did not activate the system even though they had high COOH concentration. Measurement of the zeta potential revealed that the ammonia plasma treatment raised the potential from a negative value to a positive one. Though the introduction of amino groups to the surface was not detected directly, the treatment of ammonia plasma changed the electrical state of the DLC surface having COOH group, causing a difference in blood compatibility among the DLCs obtained by various plasma conditions.

  20. The Norwegian Plasma Fractionation Project--a 12 year clinical and economic success story.

    Science.gov (United States)

    Flesland, O; Seghatchian, J; Solheim, B G

    2003-02-01

    The establishment of the Norwegian Fractionation Project (Project) was of major importance in preserving national self-sufficiency when plasma, cryoprecipitate and small batch factor IX-concentrates were replaced by virus inactivated products in the last part of the 1980s. Fractionation was performed abroad by contract with Octapharma after tenders on the European market. All Norwegian blood banks (>50) participated in the Project. Total yearly production was 50-60 tons of mainly recovered plasma. From 1993 solvent detergent (SD) treated plasma has replaced other plasma for transfusion. The blood banks paid for the fractionation and/or viral inactivation process, while the plasma remained the property of the blood banks and the final products were returned to the blood banks. The Project sold surplus products to other Norwegian blood banks and the majority of the coagulation factor concentrates to The Institute of Haemophilia and Rikshospitalet University Hospital. Both plasma and blood bank quality was improved by the Project. Clinical experience with the products has been satisfactory and self-sufficiency has been achieved for all major plasma proteins and SD plasma, but a surplus exceeding 3 years consumption of albumin has accumulated due to decreasing clinical use.The Project has secured high yields of the fractionated products and the net income from the produced products is NOK 1115 (140 Euros or US dollars) per litre plasma. An increasing surplus of albumin and the possibility of significant sales abroad of currently not fractionated IVIgG, could lead to a reorganisation of the Project from that of a co-ordinator to a national plasma handling unit. This unit could buy the plasma from the blood banks and have the plasma fractionated by contract after tender, before selling the products back for cost recovery. The small blood banks could produce plasma for products for the Norwegian market, while surplus products from the larger blood banks which are

  1. Surface modifying of microporous PTFE capillary for bilirubin removing from human plasma and its blood compatibility

    International Nuclear Information System (INIS)

    Jin Gu; Yao Qizhi; Zhang Shanzi; Zhang Lei

    2008-01-01

    In this study, human serum albumin (HSA) was covalently immobilized onto the inner surface of microporous poly(tetrafluoroethylene) (MPTFE) capillaries for direct bilirubin removal from human plasma. To obtain active binding sites for HSA, the MPTFE capillaries were chemically functionalized by using a coating of poly(vinyl alcohol) (PVA)-glycidyl methacrylate (GMA) copolymers. Characterization of grafted MPTFE capillaries was verified by XPS, Fourier transform infrared spectroscopy (FT-IR), scanning electronic microscopy (SEM). Non-specific adsorption on the PVA-GMA coated capillary remains low (< 0.38 mg bilirubin/g), and higher affinity adsorption capacity, of up to 73.6 mg bilirubin/g polymer was obtained after HSA is immobilized. Blood compatibility of the grafted MPTFE capillary was evaluated by SEM and platelet rich plasma (PRP) contacting experiments. The experimental data on blood compatibility indicated that PVA-coated and PVA-GMA-HSA coated PTFE capillary showed a sharp suppress on platelets adhesion. The proposed method has the potential of serving in bilirubin removal in clinical application

  2. Plasma and blood volume in the calf from birth till 90 days of age

    International Nuclear Information System (INIS)

    Moellerberg, L.; Ekman, L.; Jacobsson, S.-O.

    1975-01-01

    Determinations of plasma volume were made of 9 clinically healthy Swedish Red and White calves from birth to 90 days of age by means of the isotop dilution technique. Commercially available 131 I labelled human serum albumin was used. Calculation of the total blood volume was based on the plasma volume and packed cell volume. The plasma and blood volumes increased per kg body weight in average 17 and 14 percent respectively from directly after birth to 24 hrs. old. From 1 to 90 days of age the plasma and blood volume fell steadily per kg body weight. Plasma volume expressed as a percentage of body weight was 5.3 percent at birth, 6.5 percent at 1 day old, and 4.9 percent at 90 days old. Corresponding values for blood were 8.4, 9.3 and 7.0 percent. (author)

  3. Plasma-chemical processes and systems

    International Nuclear Information System (INIS)

    Castro B, J.

    1987-01-01

    The direct applications of plasma technology on chemistry and metallurgy are presented. The physical fundaments of chemically active non-equilibrium plasma, the reaction kinetics, and the physical chemical transformations occuring in the electrical discharges, which are applied in the industry, are analysed. Some plasma chemical systems and processes related to the energy of hydrogen, with the chemical technology and with the metallurgy are described. Emphasis is given to the optimization of the energy effectiveness of these processes to obtain reducers and artificial energetic carriers. (M.C.K.) [pt

  4. Self-separation of blood plasma from whole blood during the capillary flow in microchannel

    Science.gov (United States)

    Nunna, Bharath Babu; Zhuang, Shiqiang; Lee, Eon Soo

    2017-11-01

    Self-separation of blood plasma from whole blood in microchannels is of great importance due to the enormous range of applications in healthcare and diagnostics. Blood is a multiphase complex fluid, composed of cells suspended in blood plasma. RBCs are the suspended particles whose shape changes during the flow of blood. The primary constituents of blood are erythrocytes or red blood cells (RBCs), leukocytes or white blood cells (WBCs), thrombocytes or platelets and blood plasma. The existence of RBCs in blood makes the blood a non-Newtonian fluid. The current study of separation of blood plasma from whole blood during self-driven flows in a single microchannel without bifurcation, by enhancing the capillary effects. The change in the capillary effect results in a change in contact angle which directly influences the capillary flow. The flow velocity directly influences the net force acting on the RBCs and influence the separation process. The experiments are performed on the PDMS microchannels with different contact angles by altering the surface characteristics using plasma treatment. The change in the separation length is studied during the capillary flow of blood in microchannel. Bharath Babu Nunna is a researcher in mechanical engineering and implementing the novel and innovative technologies in the biomedical devices to enhance the sensitivity of the disease diagnosis.

  5. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  6. Bystander apoptosis in human cells mediated by irradiated blood plasma

    Energy Technology Data Exchange (ETDEWEB)

    Vinnikov, Volodymyr, E-mail: vlad.vinnikov@mail.ru [Grigoriev Institute for Medical Radiology of the National Academy of Medical Science of Ukraine (Ukraine); Lloyd, David; Finnon, Paul [Centre for Radiation, Chemical and Environmental Hazards of the Health Protection Agency of the United Kingdom (United Kingdom)

    2012-03-01

    Following exposure to high doses of ionizing radiation, due to an accident or during radiotherapy, bystander signalling poses a potential hazard to unirradiated cells and tissues. This process can be mediated by factors circulating in blood plasma. Thus, we assessed the ability of plasma taken from in vitro irradiated human blood to produce a direct cytotoxic effect, by inducing apoptosis in primary human peripheral blood mononuclear cells (PBM), which mainly comprised G{sub 0}-stage lymphocytes. Plasma was collected from healthy donors' blood irradiated in vitro to 0-40 Gy acute {gamma}-rays. Reporter PBM were separated from unirradiated blood with Histopaque and held in medium with the test plasma for 24 h at 37 Degree-Sign C. Additionally, plasma from in vitro irradiated and unirradiated blood was tested against PBM collected from blood given 4 Gy. Apoptosis in reporter PBM was measured by the Annexin V test using flow cytometry. Plasma collected from unirradiated and irradiated blood did not produce any apoptotic response above the control level in unirradiated reporter PBM. Surprisingly, plasma from irradiated blood caused a dose-dependent reduction of apoptosis in irradiated reporter PBM. The yields of radiation-induced cell death in irradiated reporter PBM (after subtracting the respective values in unirradiated reporter PBM) were 22.2 {+-} 1.8% in plasma-free cultures, 21.6 {+-} 1.1% in cultures treated with plasma from unirradiated blood, 20.2 {+-} 1.4% in cultures with plasma from blood given 2-4 Gy and 16.7 {+-} 3.2% in cultures with plasma from blood given 6-10 Gy. These results suggested that irradiated blood plasma did not cause a radiation-induced bystander cell-killing effect. Instead, a reduction of apoptosis in irradiated reporter cells cultured with irradiated blood plasma has implications concerning oncogenic risk from mutated cells surviving after high dose in vivo irradiation (e.g. radiotherapy) and requires further study.

  7. Bystander apoptosis in human cells mediated by irradiated blood plasma

    International Nuclear Information System (INIS)

    Vinnikov, Volodymyr; Lloyd, David; Finnon, Paul

    2012-01-01

    Following exposure to high doses of ionizing radiation, due to an accident or during radiotherapy, bystander signalling poses a potential hazard to unirradiated cells and tissues. This process can be mediated by factors circulating in blood plasma. Thus, we assessed the ability of plasma taken from in vitro irradiated human blood to produce a direct cytotoxic effect, by inducing apoptosis in primary human peripheral blood mononuclear cells (PBM), which mainly comprised G 0 -stage lymphocytes. Plasma was collected from healthy donors’ blood irradiated in vitro to 0–40 Gy acute γ-rays. Reporter PBM were separated from unirradiated blood with Histopaque and held in medium with the test plasma for 24 h at 37 °C. Additionally, plasma from in vitro irradiated and unirradiated blood was tested against PBM collected from blood given 4 Gy. Apoptosis in reporter PBM was measured by the Annexin V test using flow cytometry. Plasma collected from unirradiated and irradiated blood did not produce any apoptotic response above the control level in unirradiated reporter PBM. Surprisingly, plasma from irradiated blood caused a dose-dependent reduction of apoptosis in irradiated reporter PBM. The yields of radiation-induced cell death in irradiated reporter PBM (after subtracting the respective values in unirradiated reporter PBM) were 22.2 ± 1.8% in plasma-free cultures, 21.6 ± 1.1% in cultures treated with plasma from unirradiated blood, 20.2 ± 1.4% in cultures with plasma from blood given 2–4 Gy and 16.7 ± 3.2% in cultures with plasma from blood given 6–10 Gy. These results suggested that irradiated blood plasma did not cause a radiation-induced bystander cell-killing effect. Instead, a reduction of apoptosis in irradiated reporter cells cultured with irradiated blood plasma has implications concerning oncogenic risk from mutated cells surviving after high dose in vivo irradiation (e.g. radiotherapy) and requires further study.

  8. Variety of RNAs in Peripheral Blood Cells, Plasma, and Plasma Fractions

    Science.gov (United States)

    Kuligina, Elena V.; Bariakin, Dmitry N.; Kozlov, Vadim V.; Richter, Vladimir A.; Semenov, Dmitry V.

    2017-01-01

    Human peripheral blood contains RNA in cells and in extracellular membrane vesicles, microvesicles and exosomes, as well as in cell-free ribonucleoproteins. Circulating mRNAs and noncoding RNAs, being internalized, possess the ability to modulate vital processes in recipient cells. In this study, with SOLiD sequencing technology, we performed identification, classification, and quantification of RNAs from blood fractions: cells, plasma, plasma vesicles pelleted at 16,000g and 160,000g, and vesicle-depleted plasma supernatant of healthy donors and non-small cell lung cancer (NSCLC) patients. It was determined that 16,000g blood plasma vesicles were enriched with cell-free mitochondria and with a set of mitochondrial RNAs. The variable RNA set of blood plasma 160,000g pellets reflected the prominent contribution of U1, U5, and U6 small nuclear RNAs' fragments and at the same time was characterized by a remarkable depletion of small nucleolar RNAs. Besides microRNAs, the variety of fragments of mRNAs and snoRNAs dominated in the set of circulating RNAs differentially expressed in blood fractions of NSCLC patients. Taken together, our data emphasize that not only extracellular microRNAs but also circulating fragments of messenger and small nuclear/nucleolar RNAs represent prominent classes of circulating regulatory ncRNAs as well as promising circulating biomarkers for the development of disease diagnostic approaches. PMID:28127559

  9. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  10. Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing

    International Nuclear Information System (INIS)

    Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi

    2015-01-01

    There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (∼5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells’ trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip’s functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood. (paper)

  11. Autologous Blood and Platelet-Rich Plasma Injections for Treatment of Lateral Epicondylitis.

    Science.gov (United States)

    Calandruccio, James H; Steiner, Murphy M

    2017-07-01

    Lateral epicondylitis (tennis elbow) is a frequent cause of elbow pain; most patients (80%-90%) are successfully treated with standard nonoperative methods (rest, nonsteroidal anti-inflammatory drugs, bracing, and physical therapy). Autologous blood injections and platelet-rich plasma injections are the two most frequently used orthobiologic techniques in the treatment of lateral epicondylitis. Studies of the effectiveness of autologous blood injections and platelet-rich plasma report varying outcomes, some citing significant clinical relief and others reporting no beneficial effect. More research is needed to determine how to best use orthobiologics in the treatment of lateral epicondylitis. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Identification of clinical biomarkers for pre-analytical quality control of blood samples.

    Science.gov (United States)

    Kang, Hyun Ju; Jeon, Soon Young; Park, Jae-Sun; Yun, Ji Young; Kil, Han Na; Hong, Won Kyung; Lee, Mee-Hee; Kim, Jun-Woo; Jeon, Jae-Pil; Han, Bok Ghee

    2013-04-01

    Pre-analytical conditions are key factors in maintaining the high quality of biospecimens. They are necessary for accurate reproducibility of experiments in the field of biomarker discovery as well as achieving optimal specificity of laboratory tests for clinical diagnosis. In research at the National Biobank of Korea, we evaluated the impact of pre-analytical conditions on the stability of biobanked blood samples by measuring biochemical analytes commonly used in clinical laboratory tests. We measured 10 routine laboratory analytes in serum and plasma samples from healthy donors (n = 50) with a chemistry autoanalyzer (Hitachi 7600-110). The analyte measurements were made at different time courses based on delay of blood fractionation, freezing delay of fractionated serum and plasma samples, and at different cycles (0, 1, 3, 6, 9) of freeze-thawing. Statistically significant changes from the reference sample mean were determined using the repeated-measures ANOVA and the significant change limit (SCL). The serum levels of GGT and LDH were changed significantly depending on both the time interval between blood collection and fractionation and the time interval between fractionation and freezing of serum and plasma samples. The glucose level was most sensitive only to the elapsed time between blood collection and centrifugation for blood fractionation. Based on these findings, a simple formula (glucose decrease by 1.387 mg/dL per hour) was derived to estimate the length of time delay after blood collection. In addition, AST, BUN, GGT, and LDH showed sensitive responses to repeated freeze-thaw cycles of serum and plasma samples. These results suggest that GGT and LDH measurements can be used as quality control markers for certain pre-analytical conditions (eg, delayed processing or repeated freeze-thawing) of blood samples which are either directly used in the laboratory tests or stored for future research in the biobank.

  13. Diagnosing impaired glucose tolerance using direct infusion mass spectrometry of blood plasma.

    Directory of Open Access Journals (Sweden)

    Petr G Lokhov

    Full Text Available The goal of this study was to evaluate the capacity for mass spectrometry of blood plasma to diagnose impaired glucose tolerance (IGT. For this study, blood plasma samples from control subjects (n = 30 and patients with IGT (n = 20 were treated with methanol and low molecular weight fraction were then analyzed by direct infusion mass spectrometry. A total of 51 metabolite ions strongly associated with IGT were detected. The area under a receiver operating characteristic (ROC curve (AUC for diagnosing IGT that was based on an analysis of all these metabolites was 0.93 (accuracy 90%, specificity 90%, and sensitivity 90%. The associated reproducibility was 85%. The metabolites identified were also consistent with risk factors previously associated with the development of diabetes. Thus, direct infusion mass spectrometry of blood plasma metabolites represents a rapid, single-step, and reproducible method for the analysis of metabolites. Moreover, this method has the potential to serve as a prototype for clinical analyses that could replace the currently used glucose tolerance test with a more patient-friendly assay.

  14. Platelet Rich Plasma- mechanism of action and clinical applications

    OpenAIRE

    Cristina N. Cozma; Laura Raducu; Cristian R. Jecan

    2016-01-01

    Platelet-rich plasma (PRP) is a blood-derived fraction containing high level of platelets, a high concentration of leukocytes and growth factors. PRP therapy has been growing as a viable treatment alternative for a number of clinical applications and has a potential benefit for use in wound healing. Nowadays platelet rich plasma is used in stimulating wound healing in skin and soft tissue ulcerations, accelerating wound healing in diabetic patients and facilitating bone proliferation in ortho...

  15. A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies

    Directory of Open Access Journals (Sweden)

    Elodie Jobard

    2016-12-01

    Full Text Available The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies.

  16. Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.

    Science.gov (United States)

    Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R

    2017-10-01

    Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.

  17. Chemically reactive species in liquids generated by atmospheric-pressure plasmas and their roles in plasma medicine

    International Nuclear Information System (INIS)

    Hamaguchi, Satoshi

    2013-01-01

    Plasmas whose gas temperatures are close to room temperature may be generated in ambient air or a gas at atmospheric pressure with the use of low-frequency high voltage or low-power radio-frequency (RF) or microwave power applied to electrodes. Such plasmas can serve as a powerful source of free radicals and/or chemically reactive species that arise from atoms and molecules of the ambient gas. Recently use of such plasmas for medical purposes has attracted much attention as they can be implemented in possible medical devices that can cause blood coagulation, heal wounds, facilitate angiogenesis, sterilize surgical devices as well as living tissues without harming healthy cells, and selectively inactivate cancer cells. Especially of interest among reactive species generated by atmospheric-pressure plasmas (APP) are reactive oxygen species (ROS) and reactive nitrogen species (RNS) that are generated in liquid phase. Since most living tissues and cells are immersed in liquids (such as blood or culture media), reactive species generated by APPs in the gas phase are transported to the liquid phase and possibly converted to different types of reactive species therein before causing some influence on the tissues or cells. In this study, the rate equations are solved to evaluate concentrations of various reactive species in pure water that are originated by plasma reactions in atmosphere and possible effects of such species (including ROS/RNS) on living tissues and cells are discussed

  18. Chemically reactive species in liquids generated by atmospheric-pressure plasmas and their roles in plasma medicine

    Energy Technology Data Exchange (ETDEWEB)

    Hamaguchi, Satoshi [Center for Atomic and Molecular Technologies, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-07-11

    Plasmas whose gas temperatures are close to room temperature may be generated in ambient air or a gas at atmospheric pressure with the use of low-frequency high voltage or low-power radio-frequency (RF) or microwave power applied to electrodes. Such plasmas can serve as a powerful source of free radicals and/or chemically reactive species that arise from atoms and molecules of the ambient gas. Recently use of such plasmas for medical purposes has attracted much attention as they can be implemented in possible medical devices that can cause blood coagulation, heal wounds, facilitate angiogenesis, sterilize surgical devices as well as living tissues without harming healthy cells, and selectively inactivate cancer cells. Especially of interest among reactive species generated by atmospheric-pressure plasmas (APP) are reactive oxygen species (ROS) and reactive nitrogen species (RNS) that are generated in liquid phase. Since most living tissues and cells are immersed in liquids (such as blood or culture media), reactive species generated by APPs in the gas phase are transported to the liquid phase and possibly converted to different types of reactive species therein before causing some influence on the tissues or cells. In this study, the rate equations are solved to evaluate concentrations of various reactive species in pure water that are originated by plasma reactions in atmosphere and possible effects of such species (including ROS/RNS) on living tissues and cells are discussed.

  19. A microfluidic chip for blood plasma separation using electro-osmotic flow control

    International Nuclear Information System (INIS)

    Jiang, Hai; Weng, Xuan; Chon, Chan Hee; Wu, Xudong; Li, Dongqing

    2011-01-01

    In this paper, a microfluidic-based chip with two straight microchannels and five branch microchannels was designed and tested to separate blood plasma from a small sample of fresh human blood. The electro-osmotic flow method was used to control the separation of blood plasma. Blood cell removal and blood plasma extraction were realized in experiments. The efficiency of extracting blood plasma can be as high as 26%

  20. A method for estimation of plasma albumin concentration from the buffering properties of whole blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Diemer, Tue; Kristensen, Søren Risom

    2012-01-01

    measurements of acid-base and oxygenation status. This article presents and evaluates a new method for doing so. MATERIALS AND METHODS: The mathematical method for estimating plasma albumin concentration is described. To evaluate the method at numerous albumin concentrations, blood from 19 healthy subjects......PURPOSE: Hypoalbuminemia is strongly associated with poor clinical outcome. Albumin is usually measured at the central laboratory rather than point of care, but in principle, information exists in the buffering properties of whole blood to estimate plasma albumin concentration from point of care...

  1. Viable bacteria associated with red blood cells and plasma in freshly drawn blood donations.

    Science.gov (United States)

    Damgaard, Christian; Magnussen, Karin; Enevold, Christian; Nilsson, Martin; Tolker-Nielsen, Tim; Holmstrup, Palle; Nielsen, Claus Henrik

    2015-01-01

    Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from the oral cavity, and to determine the distribution of bacteria revealed in plasma and in the red blood cell (RBC)-fraction. Cross-sectional study. Blood were separated into plasma and RBC-suspensions, which were incubated anaerobically or aerobically for 7 days on trypticase soy blood agar (TSA) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. 60 donors (≥50 years old), self-reported medically healthy. Bacterial growth was observed on plates inoculated with plasma or RBCs from 62% of the blood donations. Growth was evident in 21 (35%) of 60 RBC-fractions and in 32 (53%) of 60 plasma-fractions versus 8 of 60 negative controls (p = 0.005 and p = 2.6x10-6, respectively). Propionibacterium acnes was found in 23% of the donations, and Staphylococcus epidermidis in 38%. The majority of bacteria identified in the present study were either facultative anaerobic (59.5%) or anaerobic (27.8%) species, which are not likely to be detected during current routine screening. Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing of RBC-fractions for adherent bacteria should be recommended.

  2. Egg beater as centrifuge: isolating human blood plasma from whole blood in resource-poor settings.

    Science.gov (United States)

    Wong, Amy P; Gupta, Malancha; Shevkoplyas, Sergey S; Whitesides, George M

    2008-12-01

    This paper demonstrates that a hand-powered egg beater can be modified to serve as a centrifuge for separating plasma from human whole blood. Immunoassays used to diagnose infectious diseases often require plasma from whole blood, and obtaining plasma typically requires electrically-powered centrifuges, which are not widely available in resource-limited settings. Human whole blood was loaded into polyethylene (PE) tubing, and the tubing was attached to the paddle of an egg beater. Spinning the paddle pelleted the blood cells to the distal end of the PE tubing; the plasma remained as the supernatant. A cholesterol assay (run on patterned paper) demonstrated the suitability of this plasma for use in diagnostic assays. The physics of the system was also analyzed as a guide for the selection of other rotating systems for use in centrifugation. Egg beaters, polyethylene tubing, and paper are readily available devices and supplies that can facilitate the use of point-of-care diagnostics at sites far from centralized laboratory facilities.

  3. Polybrominated diphenyl ethers (PBDEs) in maternal and cord blood plasma of several northern Canadian populations

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, J.J. [Bureau Chemical Safety, Health Canada, Ottawa (Canada); Oostdam, J. van [Management Toxic Substances Div., Health Canada, Ottawa (Canada)

    2004-09-15

    The Northern Contaminants Program (NCP) funded by Indian and Northern Affairs Canada has carried out a number of baseline studies in Nunavut and the North West Territories of northern Canada (figure 1) to assess the exposure of indigenous peoples to a variety of chemical classes including POPs and metals. These studies, summarized by Walker et al, have used both maternal and cord human blood plasma as the media from sampling which took place in four phases over the years 1994-1999. Small amounts of individual blood plasma have remained from these investigations. We combined these individual samples into 23 composite samples of maternal and cord blood based mainly on the region and ethnicity of the donors. These composites have been used to study the exposure of northern peoples to PBDEs and to estimate, where possible, the influence of ethnicity, region of collection, and time on such exposure. Comparison is also made between the levels in plasma from northern populations and in human milk from those inhabiting the more numerous south.

  4. Investigation on the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ma Zhongwei

    2005-01-01

    Objective: To explore the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus. Methods: Plasma homocysteine (with ELISA), blood glucose (with hexokinase method) and insulin (with RIA) levels were measured in 66 patients with type 2 diabetes mellitus as well as in 35 controls. Results: Plasma homocysteine levels in the diabetic patients (n=66) were significantly higher than those in controls (P<0.01), especially in those patients complicated with nephropathy (n=32). The homocysteine levels were positively correlated with those of blood glucose and insulin (r=0.3515, r=0.3486, both P<0.01). Conclusion: Plasma homocysteine is an independent risk factor for vascular diseases. The levels of plasma cysteine are significantly increased in patients with type 2 diabetes mellitus, especially in those complicated with nephropathy. Therefore, monitoring of plasma homocysteine level changes is clinically useful. (authors)

  5. Zwitterionic sulfobetaine-grafted poly(vinylidene fluoride) membrane with highly effective blood compatibility via atmospheric plasma-induced surface copolymerization.

    Science.gov (United States)

    Chang, Yung; Chang, Wan-Ju; Shih, Yu-Ju; Wei, Ta-Chin; Hsiue, Ging-Ho

    2011-04-01

    Development of nonfouling membranes to prevent nonspecific protein adsorption and platelet adhesion is critical for many biomedical applications. It is always a challenge to control the surface graft copolymerization of a highly polar monomer from the highly hydrophobic surface of a fluoropolymer membrane. In this work, the blood compatibility of poly(vinylidene fluoride) (PVDF) membranes with surface-grafted electrically neutral zwitterionic poly(sulfobetaine methacrylate) (PSBMA), from atmospheric plasma-induced surface copolymerization, was studied. The effect of surface composition and graft morphology, electrical neutrality, hydrophilicity and hydration capability on blood compatibility of the membranes were determined. Blood compatibility of the zwitterionic PVDF membranes was systematically evaluated by plasma protein adsorption, platelet adhesion, plasma-clotting time, and blood cell hemolysis. It was found that the nonfouling nature and hydration capability of grafted PSBMA polymers can be effectively controlled by regulating the grafting coverage and charge balance of the PSBMA layer on the PVDF membrane surface. Even a slight charge bias in the grafted zwitterionic PSBMA layer can induce electrostatic interactions between proteins and the membrane surfaces, leading to surface protein adsorption, platelet activation, plasma clotting and blood cell hemolysis. Thus, the optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and the best antifouling, anticoagulant, and antihemolytic activities when comes into contact with human blood. © 2011 American Chemical Society

  6. Monoclonal antibodies specific to heat-treated porcine blood.

    Science.gov (United States)

    Raja Nhari, Raja Mohd Hafidz; Hamid, Muhajir; Rasli, Nurmunirah Mohamad; Omar, Abdul Rahman; El Sheikha, Aly Farag; Mustafa, Shuhaimi

    2016-05-01

    Porcine blood is potentially being utilized in food as a binder, gelling agent, emulsifier or colorant. However, for certain communities, the usage of animal blood in food is strictly prohibited owing to religious concerns and health reasons. This study reports the development of monoclonal antibodies (MAbs) against heat-treated soluble proteins (HSPs) of autoclaved porcine blood; characterization of MAbs against blood, non-blood and plasma from different animal species using qualitative indirect non-competitive enzyme-linked immunosorbent assay (ELISA); and immunoblotting of antigenic components in HSPs of porcine blood. Fifteen MAbs are specific to heat-treated and raw porcine blood and not cross-reacted with other animal blood and non-blood proteins (meat and non-meat). Twelve MAbs are specific to porcine plasma, while three MAbs specific to porcine plasma are cross-reacted with chicken plasma. Immunoblotting revealed antigenic protein bands (∼60, ∼85-100 and ∼250 kDa) in porcine blood and plasma recognized by the MAbs. Selection of MAbs that recognized 60 kDa HSPs of porcine blood and plasma as novel monoclonal antibodies would be useful for detection of porcine plasma in processed food using the immunoassay method. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  7. On improved understanding of plasma-chemical processes in complex low-temperature plasmas

    Science.gov (United States)

    Röpcke, Jürgen; Loffhagen, Detlef; von Wahl, Eric; Nave, Andy S. C.; Hamann, Stephan; van Helden, Jean-Piere H.; Lang, Norbert; Kersten, Holger

    2018-05-01

    Over the last years, chemical sensing using optical emission spectroscopy (OES) in the visible spectral range has been combined with methods of mid infrared laser absorption spectroscopy (MIR-LAS) in the molecular fingerprint region from 3 to 20 μm, which contains strong rotational-vibrational absorption bands of a large variety of gaseous species. This optical approach established powerful in situ diagnostic tools to study plasma-chemical processes of complex low-temperature plasmas. The methods of MIR-LAS enable to detect stable and transient molecular species in ground and excited states and to measure the concentrations and temperatures of reactive species in plasmas. Since kinetic processes are inherent to discharges ignited in molecular gases, high time resolution on sub-second timescales is frequently desired for fundamental studies as well as for process monitoring in applied research and industry. In addition to high sensitivity and good temporal resolution, the capacity for broad spectral coverage enabling multicomponent detection is further expanding the use of OES and MIR-LAS techniques. Based on selected examples, this paper reports on recent achievements in the understanding of complex low-temperature plasmas. Recently, a link with chemical modeling of the plasma has been provided, which is the ultimate objective for a better understanding of the chemical and reaction kinetic processes occurring in the plasma. Contribution to the Topical Issue "Fundamentals of Complex Plasmas", edited by Jürgen Meichsner, Michael Bonitz, Holger Fehske, Alexander Piel.

  8. Hydrodynamic blood plasma separation in microfluidic channels

    DEFF Research Database (Denmark)

    Jouvet, Lionel

    2010-01-01

    The separation of red blood cells from plasma flowing in microchannels is possible by biophysical effects such as the Zweifach–Fung bifurcation law. In the present study, daughter channels are placed alongside a main channel such that cells and plasma are collected separately. The device is aimed...

  9. Trends of Blood and Plasma Donations in Kazakhstan: 12-Years Retrospective Analysis.

    Science.gov (United States)

    Igissinov, Nurbek; Kulmirzayeva, Dariyana; Magzumova, Raushan; Sibinga, Cees Th Smit; Alpeissova, Sholpan

    2014-05-01

    Each country faces a continuing challenge to collect enough blood to meet the national needs. According to WHO, there should be at least 20 blood donations per 1,000 population for developing countries, in Kazakhstan this indicator was only 16.8 in 2011. Thus, we conducted an epidemiological assessment and drew a map of the regional distribution of blood and plasma donations in Kazakhstan during the years 2000-2011. The retrospective study was conducted from 2000 to 2011. Data on blood and its components donations were acquired from the Ministry of Health (annual statistical reporting form N° 39). During 2000-2011, number of blood donors decreased to 17.4% and blood donations to 6.3%. The proportion of non-remunerated blood donations and donors decreased from 97.6% to 77.9% and 97.9% to 87.7%, respectively. The paid donations had the opposite trend. Number of plasma donors increased in 2.1 times, plasma donations in 2.4 times, nevertheless the proportion of non-remunerated plasma donations decreased from 60.1% to 29.8%. The average number of blood donations per 1,000 population decreased from 19.8 (2000) to 16.8 (2011), plasma donations increased from 1.4 to 3.1. Regionally, annual average rates of blood and plasma donations per 1,000 population over 12 years varied greatly. This is the first study conducted in Kazakhstan to provide detailed information, including the regional characteristics of blood and plasma donations over an extended period of time, which can be used in blood transfusion services work.

  10. Stable-isotope dilution GC-MS approach for nitrite quantification in human whole blood, erythrocytes, and plasma using pentafluorobenzyl bromide derivatization: nitrite distribution in human blood.

    Science.gov (United States)

    Schwarz, Alexandra; Modun, Darko; Heusser, Karsten; Tank, Jens; Gutzki, Frank-Mathias; Mitschke, Anja; Jordan, Jens; Tsikas, Dimitrios

    2011-05-15

    Previously, we reported on the usefulness of pentafluorobenzyl bromide (PFB-Br) for the simultaneous derivatization and quantitative determination of nitrite and nitrate in various biological fluids by GC-MS using their (15)N-labelled analogues as internal standards. As nitrite may be distributed unevenly in plasma and blood cells, its quantification in whole blood rather than in plasma or serum may be the most appropriate approach to determine nitrite concentration in the circulation. So far, GC-MS methods based on PFB-Br derivatization failed to measure nitrite in whole blood and erythrocytes because of rapid nitrite loss by oxidation and other unknown reactions during derivatization. The present article reports optimized and validated procedures for sample preparation and nitrite derivatization which allow for reliable quantification of nitrite in human whole blood and erythrocytes. Essential measures for stabilizing nitrite in these samples include sample cooling (0-4°C), hemoglobin (Hb) removal by precipitation with acetone and short derivatization of the Hb-free supernatant (5 min, 50°C). Potassium ferricyanide (K(3)Fe(CN)(6)) is useful in preventing Hb-caused nitrite loss, however, this chemical is not absolutely required in the present method. Our results show that accurate GC-MS quantification of nitrite as PFB derivative is feasible virtually in every biological matrix with similar accuracy and precision. In EDTA-anticoagulated venous blood of 10 healthy young volunteers, endogenous nitrite concentration was measured to be 486±280 nM in whole blood, 672±496 nM in plasma (C(P)), and 620±350 nM in erythrocytes (C(E)). The C(E)-to-C(P) ratio was 0.993±0.188 indicating almost even distribution of endogenous nitrite between plasma and erythrocytes. By contrast, the major fraction of nitrite added to whole blood remained in plasma. The present GC-MS method is useful to investigate distribution and metabolism of endogenous and exogenous nitrite in blood

  11. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    Science.gov (United States)

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  12. The determination of phenazone in blood plasma for obtained sistem suitable test of monitoring drug level

    Directory of Open Access Journals (Sweden)

    Mochamad Lazuardi

    2007-09-01

    Full Text Available The determining of Phenazone to human blood plasma from healthy man after separated by solid phase extraction (SPE and spectroscopic measurements has been investigated. The objective of that research was to obtain system suitable test for determine the Phenazone level in biological fluids (human blood plasma, for new performed dosage regimented in clinical dentistry. The method can be divided into the following four steps. 1. Centrifugation the blood sample, 2. Extraction from blood plasma and, 3. Separation by SPE with manual pressured, 4. Elution to SPE followed by the measurement on a spectrophotometer in the ultra violet region. The critical value of  │t │at the 5% confidence level indicates that there is no systematic error in the linearity proposed method. Recoveries for this research were obtained at ranging 93.460 to 95.598%. The coefficient variation precision of this procedure was clearly good at smallest than 2%. The analytical procedure can be carried out in one working operation as a monitored therapeutic activity.

  13. Fluorescence spectra of blood plasma treated with ultraviolet irradiation in vivo

    Science.gov (United States)

    Zalesskaya, G. A.; Maslova, T. O.

    2010-09-01

    We have studied the fluorescence spectra of blood plasma from patients with acute coronary syndrome, and also the effect of therapeutic doses of in vivo ultraviolet blood irradiation (UBI) on the spectra. We have established that the maxima in the fluorescence spectra of the original plasma samples, obtained from unirradiated blood, are located in the wavelength interval 330-340 nm, characteristic for the fluorescence of tryptophan residues. In extracorporeal UBI ( λ = 254 nm), we observed changes in the shape and also both a blue and a red shift in the maxima of the fluorescence spectra, differing in magnitude for blood plasma samples from different patients in the test group. We show that UBI-initiated changes in the fluorescence spectra of the plasma depend on the original pathological disturbances of metabolite levels, and also on the change in the oxygen-transport function of the blood and the acid-base balance, affecting the oxidative stability of the plasma. We have concluded that UV irradiation, activating buffer systems in the blood, has an effect on the universal and specific interactions of the tryptophan residue with the amino acid residues and water surrounding it.

  14. Effect of Ichthyophonus on blood plasma chemistry of spawning Chinook salmon and their resulting offspring in a Yukon River tributary.

    Science.gov (United States)

    Floyd-Rump, T P; Horstmann-Dehn, L A; Atkinson, S; Skaugstad, C

    2017-01-24

    Ichthyophonus is a protozoan parasite of Alaska Chinook salmon Oncorhynchus tshawytscha. In this study, we determined whether spawning Chinook salmon in the Yukon River drainage exhibited a measurable stress response (i.e. elevated plasma cortisol concentrations) and detectable changes in selected blood plasma chemistry parameters when infected with Ichthyophonus. The resulting alevin were also analyzed for any differences in blood plasma chemistry caused by parental infection with Ichthyophonus. In 2010, 2011, and 2012, spawning adult Chinook salmon were collected from the Salcha River, Alaska, USA, and the prevalence of Ichthyophonus in these fish was 7.8, 6.3, and 8.3%, respectively. Fish with no clinical signs of Ichthyophonus and Ichthyophonus-positive parents were cross-fertilized to investigate potential second-generation effects as a result of Ichthyophonus infection. We found no significant difference in cortisol concentrations in blood plasma between Ichthyophonus-positive and -negative adults or between alevin from Ichthyophonus-positive and -negative parents. There were no significant differences in blood plasma parameters (e.g. alanine aminotransferase, creatine kinase, glucose) of Ichthyophonus-negative and -positive adults, with the exception of aspartate aminotransferase, which was significantly higher in plasma of Ichthyophonus-negative adults. All clinical chemistry parameters for alevin resulting from both Ichthyophonus-negative and -positive parents were not significantly different. Based on this study, which has a limited sample size and low prevalence of Ichthyophonus, offspring of Chinook salmon appear to suffer no disadvantage as a result of Ichthyophonus infection in their parents on the Salcha River.

  15. Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    Science.gov (United States)

    McGrath, Rachel T; Donnelly, Vanessa C; Glastras, Sarah J; Preda, Veronica A; Sheriff, Nisa; Ward, Peter; Hocking, Samantha L; Fulcher, Gregory R

    2016-02-01

    The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; however, the accuracy of blood glucose meters in pregnancy is unclear. Pregnant women with gestational, type 1, or type 2 diabetes mellitus were eligible to participate. Nonfasting capillary blood glucose levels were measured in duplicate using the BGStar(®) (Sanofi, Sydney, Australia) and FreeStyle Lite(®) (Abbott, Sydney) blood glucose meters. Venous blood samples were collected and analyzed for plasma glucose, hematocrit, and glycated hemoglobin. Capillary blood glucose was compared with plasma glucose and further assessed according to International Organization for Standardization (ISO) 15197:2013 standards. One hundred ten women were recruited, providing 96 samples suitable for analysis. The mean ± SD laboratory plasma glucose level was 4.6 ± 1.4 mmol/L; the BGStar and FreeStyle Lite capillary blood glucose values were 5.3 ± 1.4 mmol/L and 5.0 ± 1.3 mmol/L, respectively. Both meters showed a positive bias (0.42 mmol/L for the FreeStyle Lite and 0.65 mmol/L for the BGStar). Furthermore, neither meter fulfilled the ISO 15197:2013 standards, and there was a nonsignificant improvement in meter performance at blood glucose levels of ≤4.2 mmol/L. Hematocrit did not affect the results of either blood glucose meter. Clarke Error Grid analysis demonstrated that approximately 70% of the results of both meters would lead to appropriate clinical action. The BGStar and FreeStyle Lite blood glucose meters did not meet ISO 15197:2013 recommendations for blood glucose monitoring systems when assessed in a population of women with diabetes in pregnancy. Clinicians should consider this difference in blood glucose readings when making diabetes

  16. A Systematic Review and Meta-Analysis of the Clinical Appropriateness of Blood Transfusion in China.

    Science.gov (United States)

    Zhu, Changtai; Gao, Yulu; Li, Zhiqiang; Li, Qinyun; Gao, Zongshuai; Liao, Yanqiu; Deng, Zhifeng

    2015-12-01

    The issue of the clinical appropriateness of blood transfusion has become a focus of transfusion medicine worldwide. In China, irrational uses of blood have often been reported in recent years. However, to date there lacks a systematic review of the rational uses of blood. This study aimed to determine the clinical appropriateness of blood transfusion in China. We searched PubMed, Web of Science, the Cochrane Library, China National Knowledge Infrastructure (CNKI), China Science and Technology Journal Database, WanFang Database, and Chinese BioMedical Literature Database, and the retrieval cut-off date was June 31, 2015. SPSS 17.0 and MetaAnalyst 3.13 were employed as the statistics tools in this review. A pooled rate of clinical inappropriateness of transfusion was analyzed by DerSimonian-Laird method. In this study, a total of 39 observational studies were included, which related to 75,132 cases of blood transfusion. According to the meta-analysis results, the overall incidence of clinical inappropriateness of transfusion in China was estimated to be 37.3% (95% confidence interval [CI] [32.1, 42.8]). The subgroup analyses revealed that the pooled rates of clinical inappropriateness of transfusion of plasma, red blood cells (RBCs), cryoprecipitate, and platelets were 56.3% (95% CI [45.8, 66.2]), 30.9% (95% CI [27.1, 35.0]), 25.2% (95% CI [13.2, 42.7]), and 14.1% (95% CI [8.8, 21.9]), respectively. However, the pooled incidence of inappropriateness of transfusion in operative departments was 47.5% (95% CI [36.8, 58.3]), which was significantly higher than that in nonoperative departments, 25.8% (95% CI [18.7, 34.4], P  0.05). In conclusion, China has suffered from a disadvantage in the clinical appropriateness of blood transfusion, especially in plasma and RBC use. In future, comprehensive measures should be implemented in order to improve the clinical appropriateness of blood transfusion.

  17. Platelet Rich Plasma- mechanism of action and clinical applications

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2016-11-01

    Full Text Available Platelet-rich plasma (PRP is a blood-derived fraction containing high level of platelets, a high concentration of leukocytes and growth factors. PRP therapy has been growing as a viable treatment alternative for a number of clinical applications and has a potential benefit for use in wound healing. Nowadays platelet rich plasma is used in stimulating wound healing in skin and soft tissue ulcerations, accelerating wound healing in diabetic patients and facilitating bone proliferation in orthopedic and trauma surgery. It has also applications in maxillofacial surgery, spinal surgery, plastic and esthetic surgery, heart surgery and burns. This review of the literature shows a limited number of studies realized on humans that sustain PRP applications in orthopedic and plastic surgery. As the use of PRP increases, more properly structured clinical studies are necessary to confirm the results and to establish clearly the techniques of preparing, the conditions and the clinical indications of applying this therapy.

  18. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    Science.gov (United States)

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87albumin and total protein in human plasma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Combustion flame-plasma hybrid reactor systems, and chemical reactant sources

    Science.gov (United States)

    Kong, Peter C

    2013-11-26

    Combustion flame-plasma hybrid reactor systems, chemical reactant sources, and related methods are disclosed. In one embodiment, a combustion flame-plasma hybrid reactor system comprising a reaction chamber, a combustion torch positioned to direct a flame into the reaction chamber, and one or more reactant feed assemblies configured to electrically energize at least one electrically conductive solid reactant structure to form a plasma and feed each electrically conductive solid reactant structure into the plasma to form at least one product is disclosed. In an additional embodiment, a chemical reactant source for a combustion flame-plasma hybrid reactor comprising an elongated electrically conductive reactant structure consisting essentially of at least one chemical reactant is disclosed. In further embodiments, methods of forming a chemical reactant source and methods of chemically converting at least one reactant into at least one product are disclosed.

  20. 77 FR 6463 - Revisions to Labeling Requirements for Blood and Blood Components, Including Source Plasma...

    Science.gov (United States)

    2012-02-08

    ... Blood Components, Including Source Plasma; Correction AGENCY: Food and Drug Administration, HHS. ACTION..., Including Source Plasma,'' which provided incorrect publication information regarding a 60-day notice that...

  1. Quantitation of 5-Methyltetrahydrofolic Acid in Dried Blood Spots and Dried Plasma Spots by Stable Isotope Dilution Assays.

    Directory of Open Access Journals (Sweden)

    Markus Kopp

    Full Text Available Because of minimal data available on folate analysis in dried matrix spots (DMSs, we combined the advantages of stable isotope dilution assays followed by LC-MS/MS analysis with DMS sampling to develop a reliable method for the quantitation of plasma 5-methyltetrahydrofolic acid in dried blood spots (DBSs and dried plasma spots (DPSs as well as for the quantitation of whole blood 5-methyltetrahydrofolic acid in DBSs. We focused on two diagnostically conclusive parameters exhibited by the plasma and whole blood 5-methyltetrahydrofolic acid levels that reflect both temporary and long-term folate status. The method is performed using the [2H4]-labeled isotopologue of the vitamin as the internal standard, and three steps are required for the extraction procedure. Elution of the punched out matrix spots was performed using stabilization buffer including Triton X-100 in a standardized ultrasonication treatment followed by enzymatic digestion (whole blood only and solid-phase extraction with SAX cartridges. This method is sensitive enough to quantify 27 nmol/L whole blood 5-methyltetrahydrofolic acid in DBSs and 6.3 and 4.4 nmol/L plasma 5-methyltetrahydrofolic acid in DBSs and DPSs, respectively. The unprecedented accurate quantification of plasma 5-methyltetrahydrofolic acid in DBSs was achieved by thermal treatment prior to ultrasonication, inhibiting plasma conjugase activity. Mass screenings are more feasible and easier to facilitate for this method in terms of sample collection and storage compared with conventional clinical sampling for the assessment of folate status.

  2. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  3. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    International Nuclear Information System (INIS)

    Prysiazhnyi, Vadym; Slavicek, Pavel; Klima, Milos; Mikmekova, Eliska

    2016-01-01

    This paper is aimed to show the influence of initial chemical pretreatment prior to subsequent plasma activation of aluminum surfaces. The results of our study showed that the state of the topmost surface layer (i.e. the surface morphology and chemical groups) of plasma modified aluminum significantly depends on the chemical precleaning. Commonly used chemicals (isopropanol, trichlorethane, solution of NaOH in deionized water) were used as precleaning agents. The plasma treatments were done using a radio frequency driven atmospheric pressure plasma pencil developed at Masaryk University, which operates in Ar, Ar/O 2 gas mixtures. The effectiveness of the plasma treatment was estimated by the wettability measurements, showing high wettability improvement already after 0.3 s treatment. The effects of surface cleaning (hydrocarbon removal), surface oxidation and activation (generation of OH groups) were estimated using infrared spectroscopy. The changes in the surface morphology were measured using scanning electron microscopy. Optical emission spectroscopy measurements in the near-to-surface region with temperature calculations showed that plasma itself depends on the sample precleaning procedure. (paper)

  4. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    Science.gov (United States)

    Vadym, Prysiazhnyi; Pavel, Slavicek; Eliska, Mikmekova; Milos, Klima

    2016-04-01

    This paper is aimed to show the influence of initial chemical pretreatment prior to subsequent plasma activation of aluminum surfaces. The results of our study showed that the state of the topmost surface layer (i.e. the surface morphology and chemical groups) of plasma modified aluminum significantly depends on the chemical precleaning. Commonly used chemicals (isopropanol, trichlorethane, solution of NaOH in deionized water) were used as precleaning agents. The plasma treatments were done using a radio frequency driven atmospheric pressure plasma pencil developed at Masaryk University, which operates in Ar, Ar/O2 gas mixtures. The effectiveness of the plasma treatment was estimated by the wettability measurements, showing high wettability improvement already after 0.3 s treatment. The effects of surface cleaning (hydrocarbon removal), surface oxidation and activation (generation of OH groups) were estimated using infrared spectroscopy. The changes in the surface morphology were measured using scanning electron microscopy. Optical emission spectroscopy measurements in the near-to-surface region with temperature calculations showed that plasma itself depends on the sample precleaning procedure.

  5. Measurement of Uranium in Blood-Plasma of Bavarian Females

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Watling, R.J.

    2011-01-01

    It has recently been reported that the water supply in some parts of Bavaria (Germany) contains Uranium. In order to study its effects we have determined the concentrations of U in the blood plasma of 25 females. All the females came from Bavaria and were not on any medication. Blood samples were drawn from a superficial arm vein, centrifuged and plasma extracted. The plasma samples were freeze-dried and analysed in our Analytical Laboratory in Perth, Western Australia by using the technique of ICP-MS. The U contents found varied from less than 0.1 to 8.2 ppb (6.6 ng/L to 543 ng/L)

  6. Fundamental aspects of plasma chemical physics Thermodynamics

    CERN Document Server

    Capitelli, Mario; D'Angola, Antonio

    2012-01-01

    Fundamental Aspects of Plasma Chemical Physics - Thermodynamics develops basic and advanced concepts of plasma thermodynamics from both classical and statistical points of view. After a refreshment of classical thermodynamics applied to the dissociation and ionization regimes, the book invites the reader to discover the role of electronic excitation in affecting the properties of plasmas, a topic often overlooked by the thermal plasma community. Particular attention is devoted to the problem of the divergence of the partition function of atomic species and the state-to-state approach for calculating the partition function of diatomic and polyatomic molecules. The limit of ideal gas approximation is also discussed, by introducing Debye-Huckel and virial corrections. Throughout the book, worked examples are given in order to clarify concepts and mathematical approaches. This book is a first of a series of three books to be published by the authors on fundamental aspects of plasma chemical physics.  The next bo...

  7. Wave propagation in a quasi-chemical equilibrium plasma

    Science.gov (United States)

    Fang, T.-M.; Baum, H. R.

    1975-01-01

    Wave propagation in a quasi-chemical equilibrium plasma is studied. The plasma is infinite and without external fields. The chemical reactions are assumed to result from the ionization and recombination processes. When the gas is near equilibrium, the dominant role describing the evolution of a reacting plasma is played by the global conservation equations. These equations are first derived and then used to study the small amplitude wave motion for a near-equilibrium situation. Nontrivial damping effects have been obtained by including the conduction current terms.

  8. Quality assurance of clinical transfusion practice by implementation of the privilege of blood prescription and computerized prospective audit of blood requests.

    Science.gov (United States)

    Marconi, M; Almini, D; Pizzi, M N; Riccardi, D; Bergamaschi, W; Giovanetti, A M; Rebulla, P; Sirchia, G

    1996-03-01

    Guidelines, algorithms and recommendations have been issued in the attempt to ensure appropriateness of transfusion practice, but the results are less than satisfactory, mainly due to the difficulty to turn paper procedures into actual practice. In our hospital we have tried to overcome this difficulty through the implementation of a quality assurance programme which includes giving the privilege of nonurgent blood prescription to a limited number of physicians and a computerized prospective audit of blood requests. The latter is performed through verification of the compliance of blood requests, which are designed to include a patient's laboratory and clinical data, with hospital guidelines for the proper use of blood. In the 12 months since implementation of the computerized prospective audit the transfusion service has evaluated 7884 requests. Of these, 63.4% (n = 4998) were for red blood cells, 21.1% (n = 1664) for platelets and 15.5% (n = 1222) for fresh frozen plasma. The prospective audit showed that 96.8% and 98.1% of requests for red units and platelets were appropriate, respectively. Conversely, approximately 27% of plasma requests did not comply with guidelines, mainly because the evidence of coagulopathy was missing. However, inappropriateness of plasma requests for elective general surgery decreased from 39% at the onset of the programme to 14% in the last trimester considered. Moreover, the evaluation by retrospective audit of the proportion of patients transfused with both red blood cells and plasma in the perioperative period out of those transfused with red blood cells only, as an indicator of unwanted reconstitution of whole blood, showed that this proportion decreased from 47.6% (320/672) in the 12 months before implementation of computerized audit to 37.8% (244/646) in the following 12 months (difference = -9.8%, 95% confidence interval of the difference from -4.5% to -15.1%; P audit is a useful tool for assuring the quality of blood requesting.

  9. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak

    2012-01-01

    design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P ...Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover......, a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were...

  10. Biochemical characterization of blood plasma of coronary artery ...

    Indian Academy of Sciences (India)

    This study aimed to investigate the biochemical profile of blood plasma of patients with coronary artery disease (CAD) and angiographically normal subjects (controls) to determine biomarkers for their differentiation. In this double blind study, 5 mL venous blood was drawn before angiography from CAD patients (n=60) and ...

  11. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  12. A simple method to quantitate IP-10 in dried blood and plasma spots.

    Directory of Open Access Journals (Sweden)

    Martine G Aabye

    Full Text Available BACKGROUND: Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. AIM: To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS and dried plasma spots (DPS; to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV and M.tuberculosis specific immune responses. METHOD: We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. RESULTS: The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5-600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37 °C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r(2>0.97. CONCLUSIONS: This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection.

  13. Strangeness Production in a Chemically Equilibrating Quark-Gluon Plasma

    Institute of Scientific and Technical Information of China (English)

    HE Ze-Jun; LONG Jia-Li; MA Yu-Gang; MA Guo-Liang

    2004-01-01

    @@ We study the strangeness of a chemically equilibrating quark-gluon plasma at finite baryon density based on the and will accelerate with the change of the initial system from a chemically non-equilibrated to an equilibrated system. We also find that the calculated strangeness is very different from the one in the thermodynamic equilibrium system. This study may be helpful to understand the formation of quark-gluon plasma via a chemically non-equilibrated evolution framework.

  14. Using NMR metabolomics to identify responses of an environmental estrogen in blood plasma of fish

    International Nuclear Information System (INIS)

    Samuelsson, Linda M.; Foerlin, Lars; Karlsson, Goeran; Adolfsson-Erici, Margaretha; Larsson, D.G. Joakim

    2006-01-01

    Nuclear magnetic resonance (NMR) based metabolomics in combination with multivariate data analysis may become valuable tools to study environmental effects of pharmaceuticals and other chemicals in aquatic organisms. To explore the usefulness of this approach in fish, we have used 1 H NMR metabolomics to compare blood plasma and plasma lipid extracts from rainbow trout exposed to the synthetic contraceptive estrogen ethinylestradiol (EE 2 ) with plasma from control fish. The plasma metabolite profile was affected in fish exposed to 10 ng/L but not 0.87 ng/L of EE 2 , which was in agreement with an induced vitellogenin synthesis in the high dose group only, as measured by ELISA. The main affected metabolites were vitellogenin, alanine, phospholipids and cholesterol. The responses identified by this discovery-driven method could be put in context with previous knowledge of the effects of estrogens on fish. This adds confidence to the approach of using NMR metabolomics to identify environmental effects of pharmaceuticals and other contaminants

  15. All Clinically-Relevant Blood Components Transmit Prion Disease following a Single Blood Transfusion: A Sheep Model of vCJD

    Science.gov (United States)

    de Wolf, Christopher; Tan, Boon Chin; Smith, Antony; Groschup, Martin H.; Hunter, Nora; Hornsey, Valerie S.; MacGregor, Ian R.; Prowse, Christopher V.; Turner, Marc; Manson, Jean C.

    2011-01-01

    Variant CJD (vCJD) is an incurable, infectious human disease, likely arising from the consumption of BSE-contaminated meat products. Whilst the epidemic appears to be waning, there is much concern that vCJD infection may be perpetuated in humans by the transfusion of contaminated blood products. Since 2004, several cases of transfusion-associated vCJD transmission have been reported and linked to blood collected from pre-clinically affected donors. Using an animal model in which the disease manifested resembles that of humans affected with vCJD, we examined which blood components used in human medicine are likely to pose the greatest risk of transmitting vCJD via transfusion. We collected two full units of blood from BSE-infected donor animals during the pre-clinical phase of infection. Using methods employed by transfusion services we prepared red cell concentrates, plasma and platelets units (including leucoreduced equivalents). Following transfusion, we showed that all components contain sufficient levels of infectivity to cause disease following only a single transfusion and also that leucoreduction did not prevent disease transmission. These data suggest that all blood components are vectors for prion disease transmission, and highlight the importance of multiple control measures to minimise the risk of human to human transmission of vCJD by blood transfusion. PMID:21858015

  16. Clinical significance of 2 h plasma concentrations of first-line anti-tuberculosis drugs

    DEFF Research Database (Denmark)

    Prahl, Julie B; Johansen, Isik S; Cohen, Arieh S

    2014-01-01

    OBJECTIVES: To study 2 h plasma concentrations of the first-line tuberculosis drugs isoniazid, rifampicin, ethambutol and pyrazinamide in a cohort of patients with tuberculosis in Denmark and to determine the relationship between the concentrations and the clinical outcome. METHODS: After 6......-207 days of treatment (median 34 days) 2 h blood samples were collected from 32 patients with active tuberculosis and from three patients receiving prophylactic treatment. Plasma concentrations were determined using LC-MS/MS. Normal ranges were obtained from the literature. Clinical charts were reviewed...... failure occurred more frequently when the concentrations of isoniazid and rifampicin were both below the normal ranges (P = 0.013) and even more frequently when they were below the median 2 h drug concentrations obtained in the study (P = 0.005). CONCLUSIONS: At 2 h, plasma concentrations of isoniazid...

  17. Comparison of EBV DNA viral load in whole blood, plasma, B-cells and B-cell culture supernatant.

    Science.gov (United States)

    Ouedraogo, David Eric; Bollore, Karine; Viljoen, Johannes; Foulongne, Vincent; Reynes, Jacques; Cartron, Guillaume; Vendrell, Jean-Pierre; Van de Perre, Philippe; Tuaillon, Edouard

    2014-05-01

    Epstein-Barr virus (EBV) genome quantitation in whole blood is used widely for therapeutic monitoring of EBV-associated disorders in immunosuppressed individuals and in patients with EBV-associated lymphoma. However, the most appropriate biological material to be used for EBV DNA quantitation remains a subject of debate. This study compare the detection rate and levels of EBV DNA from whole blood, plasma, enriched B-cells, and B-cell short-term culture supernatant using quantitative real-time PCR. Samples were collected from 33 subjects with either HIV infection or B-cell lymphoma. Overall, EBV DNA was detected in 100% of enriched B-cell samples, in 82% of B-cell culture supernatants, in 57% of plasma, and 42% of whole blood samples. A significant correlation for EBV viral load was found between enriched B-cell and B-cell culture supernatant material (ρ = 0.92; P cells (ρ = -0.02; P = 0.89), whole blood and plasma (ρ = 0.24; P = 0.24), or enriched B-cells and plasma (ρ = 0.08; P = 0.77). Testing of enriched B-cells appeared to be the most sensitive method for detection of EBV DNA as well as for exploration of the cellular reservoir. Quantitation of EBV DNA in plasma and B-cell culture supernatant may be of interest to assess EBV reactivation dynamics and response to treatment as well as to decipher EBV host-pathogen interactions in various clinical scenarios. © 2013 Wiley Periodicals, Inc.

  18. Apolipoprotein E in umbilical cord blood plasma

    International Nuclear Information System (INIS)

    Forte, T.M.; Davis, P.A.; Blum, C.B.

    1983-01-01

    Adolipoprotein E (apo E), with a molecular weight of approximately 37,000 daltons, is a minor apolipoprotein constituent in adult plasma lipoproteins. This apolipoprotein, like apolipoprotein B, is a ligand recognized by specific lipoprotein receptor sites (B-E receptors) on cell surfaces. We have recently shown that a pronounced apo E band appears in umbilical cord blood low-density (LDL) lipoproteins and also in high density (HDL) lipoproteins. Densitometric scans of Coomassie blue G-250 stained polyacrylamide gels suggested that apo E was probably elevated in cord blood lipoproteins. To pursue this suggestion, apo E in cord blood was quantitated by radioimmunoassay and correlated with cord blood lipid levels. In addition, apo E levels in 20 normal adult volunteers were also examined

  19. Determination of telmisartan in human blood plasma: Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent

  20. A high plasma: red blood cell transfusion ratio during liver transplantation is associated with decreased blood utilization.

    Science.gov (United States)

    Pagano, M B; Metcalf, R A; Hess, J R; Reyes, J; Perkins, J D; Montenovo, M I

    2018-04-01

    During massive transfusion, the volume ratio of administered plasma (PL Vol) to red blood cell (RBC Vol) appears to be associated with reduced blood utilization and improved survival. The aim of this study was to evaluate the optimal component ratio in the setting of liver transplantation. This is a retrospective chart review of patients who underwent liver transplantation and received at least 500 ml of red blood cells from January 2013 through December 2015. Kernel smoothing analysis determined the proper component ratios to evaluate were a ≥0·85:1 ratio (high) to a ≤0·85:1 ratio (low). Two groups, plasma volume to RBC volume (PL Vol/RBC Vol) and plasma contained in the platelet units added to the plasma calculation [PL + PLT (platelet)] Vol/RBC Vol, were used to evaluate the component ratios. A total of 188 patients were included in the analysis. In the PL Vol/RBC Vol evaluation, a low ratio revealed that 1238 ml (977-1653 ml) (P ratio, in the univariable and multivariable analysis, respectively. In the PL +PLT Vol/RBC Vol evaluation, a low ratio used 734 ml (193-1275) (P = 0·008) and 886 ml (431-1340) (P ratio in the univariable and multivariable analysis, respectively. In patients undergoing liver transplantation, the transfusion of plasma to RBC ratio ≥0·85 was associated with decreased need of RBC transfusions. © 2018 International Society of Blood Transfusion.

  1. Turnover of adenosine in plasma of human and dog blood

    International Nuclear Information System (INIS)

    Moeser, G.H.S.; Schrader, J.; Deussen, A.

    1989-01-01

    To determine half-life and turnover of plasma adenosine, heparinized blood from healthy volunteers was incubated with radiolabeled adenosine in the physiological concentration range of 0.1-1 microM. Plasma levels of adenosine in vitro were 82 +/- 14 nM and were similar to those determined immediately after blood collection with a ''stopping solution.'' Dipyridamole (83 microM) and erythro-9(2-hydroxynon-3yl)-adenine (EHNA) (8 microM) did not measurably alter basal adenosine levels but completely blocked the uptake of added adenosine. Inhibition of ecto-5'-nucleotidase with 100 microM alpha, beta-methyleneadenosine 5'-diphosphate (AOPCP) reduced plasma adenosine to 22 +/- 6 nM. For the determination of adenosine turnover, the decrease in specific radioactivity of added [ 3 H]adenosine was measured using a dipyridamole-containing stopping solution. Without altering basal adenosine levels, the half-life was estimated to be 0.6 s. Similar experiments were carried out with washed erythrocytes or in the presence of AOPCP, yielding half-lives of 0.7 and 0.9 s, respectively. When the initial adenosine concentration was 1 microM, its specific activity decreased by only 11% within 5 s, whereas total plasma adenosine exponentially decreased with a half-life of 1.5 s. Venous plasma concentrations were measured after relief of a 3-min forearm ischemia. Changes in plasma adenosine did not correlate well with changes in blood flow but were augmented in the presence of dipyridamole

  2. Effect of Platelet-Rich Plasma (PRP versus Autologous Whole Blood on Pain and Function Improvement in Tennis Elbow: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Seyed Ahmad Raeissadat

    2014-01-01

    Full Text Available Background. Autologous whole blood and platelet-rich plasma (PRP have been both suggested to treat chronic tennis elbow. The aim of the present study was to compare the effects of PRP versus autologous whole blood local injection in chronic tennis elbow. Methods. Forty patients with tennis elbow were randomly divided into 2 groups. Group 1 was treated with a single injection of 2 mL of autologous PRP and group 2 with 2 mL of autologous blood. Tennis elbow strap, stretching, and strengthening exercises were administered for both groups during a 2-month followup. Pain and functional improvements were assessed using visual analog scale (VAS, modified Mayo Clinic performance index for the elbow, and pressure pain threshold (PPT at 0, 4, and 8 weeks. Results. All pain and functional variables including VAS, PPT, and Mayo scores improved significantly in both groups 4 weeks after injection. No statistically significant difference was noted between groups regarding pain scores in 4-week follow-up examination (P>0.05. At 8-week reevaluations, VAS and Mayo scores improved only in PRP group (P<0.05. Conclusion. PRP and autologous whole blood injections are both effective to treat chronic lateral epicondylitis. PRP might be slightly superior in 8-week followup. However, further studies are suggested to get definite conclusion.

  3. Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) in the discrimination of normal and oral cancer blood plasma

    Science.gov (United States)

    Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan

    2017-02-01

    Oral cancer is the most frequent type of cancer that occurs with 75000 to 80000 new cases reported every year in India. The carcinogens from tobacco and related products are the main cause for the oral cancer. ATR-FTIR method is label free, fast and cost-effective diagnostic method would allow for rapid diagnostic results in earlier stages by the minimal chemical changes occur in the biological metabolites available in the blood plasma. The present study reports the use of ATR-FTIR data with advanced statistical model (LDA-ANN) in the diagnosis of oral cancer from normal with better accuracy. The infrared spectra were acquired on ATR-FTIR Jasco spectrophotometer at 4 cm-1 resolution, 30 scans, in the 1800-900 cm-1 spectral range. Each sample had 5 spectra recorded from each blood plasma sample. The spectral data were routed through the multilayer perception of artificial neural network to evaluate for the statistical efficacy. Among the spectral data it was found that amide II (1486 cm-1) and lipid (1526 cm-1) affords about 90 % in the discrimination between groups using LDA. These preliminary results indicate that ATR-FTIR is useful to differentiate normal subject from oral cancer patients using blood plasma.

  4. Assessment of three frequently used blood glucose monitoring devices in clinical routine.

    Science.gov (United States)

    Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R

    2012-07-12

    Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.

  5. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  6. Association of Blood and Seminal Plasma Cadmium and Lead Levels With Semen Quality in Non-Occupationally Exposed Infertile Men in Abakaliki, South East Nigeria

    Directory of Open Access Journals (Sweden)

    Ademola C Famurewa

    2017-10-01

    Full Text Available Objective: To evaluate association of blood and seminal plasma lead and cadmium with sperm quality of non-occupationally exposed male partners of couples with infertility.Materials and methods: A cross-sectional study was conducted on 75 men aged 20-45 years (mean = 37.1 ± 7.0 yrs. with infertility recruited from the Fertility Clinic of a hospital in Abakaliki. Sperm count done in accordance with the WHO guidelines was used to classify the participants as normospamia, oligospermia and azospermia. Atomic absorption spectrophotometer was used to determine lead and cadmium levels in plasma from blood and semen.Results: There were 15 azospermics, 22 oligospermics and 36 normospermics. Seminal and blood plasma cadmium as well as blood plasma lead were significantly (p < 0.01 higher in azospermic and oligospermic men compared to normospermic men. However, while seminal plasma lead was significantly (p < 0.05 higher in oligospermic and normospernic men than in azospermic men, the seminal plasma lead was comparable between oligospermic and normospermic men. Significant inverse associations (p < 0.01 were found between blood and seminal cadmium levels and sperm count, motility and morphology; blood lead was inversely correlated with sperm count only.Conclusion: The study suggests that environmental exposure to cadmium and lead may contribute to development of poor sperm quality and infertility in men of reproductive age in Nigeria.

  7. Extracellular membrane vesicles in blood products-biology and clinical relevance

    Directory of Open Access Journals (Sweden)

    Emilija Krstova Krajnc

    2016-01-01

    Full Text Available Extracellular membrane vesicles are fragments shed from plasma membranes off all cell types that are undergoing apoptosis or are being subjected to various types of stimulation or stress.  Even in the process of programmed cell death (apoptosis, cell fall apart of varying size vesicles. They expose phosphatidylserine (PS on the outer leaflet of their membrane, and bear surface membrane antigens reflecting their cellular origin. Extracellular membrane vesicles have been isolated from many types of biological fluids, including serum, cerebrospinal fluid, urine, saliva, tears and conditioned culture medium. Flow cytometry is one of the many different methodological approaches that have been used to analyze EMVs. The method attempts to characterize the EMVs cellular origin, size, population, number, and structure. EMVs are present and accumulate in blood products (erythrocytes, platelets as well as in fresh frozen plasma during storage. The aim of this review is to highlight the importance of extracellular vesicles as a cell-to-cell communication system and the role in the pathogenesis of different diseases. Special emphasis will be given to the implication of extracellular membrane vesicles in blood products and their clinical relevance. Although our understanding of the role of  EMVs in disease is far from comprehensive, they display promise as biomarkers for different diseases in the future and also as a marker of quality and safety in the quality control of blood products.

  8. Interaction of blood plasma with antifouling surfaces

    Czech Academy of Sciences Publication Activity Database

    Rodriguez-Emmenegger, Cesar; Brynda, Eduard; Riedel, Tomáš; Sedláková, Zdeňka; Houska, Milan; Bologna Alles, A.

    2009-01-01

    Roč. 25, č. 11 (2009), s. 6328-6333 ISSN 0743-7463 R&D Projects: GA AV ČR KAN200670701 Institutional research plan: CEZ:AV0Z40500505 Keywords : blood plasma fouling * antigouling coatings * SPR biosensors Subject RIV: CE - Biochemistry Impact factor: 3.898, year: 2009

  9. Aminotransferases and Leucine Aminopeptidase Activity in Blood Plasma of Chickens

    International Nuclear Information System (INIS)

    Kraljevic, P.; Stojevic, Z.; Milinkovic-Tur, S.; Simpraga, M.; Miljanic, S.

    1998-01-01

    It has been reported that irradiation of mammals by gama-rays cause increase of some enzyme activity in their blood plasma (Miller and Gates 1949; Milch and Albaum 1959; Hughes 1958; Miholjcic et al. 1979). In our previous papers (Kraljevic et al., 1982; Kraljevic and Emanovic 1993) it has been shown that activities of some enzymes in the blood plasma of chickens after an intramuscular injection of radioactive isotope 32 P. In this paper an attempt has been made to investigate the influence of gamma-ray irradiation of the whole body of chickens upon activity of some enzymes in their blood plasma. We also wanted to investigate whether the activity of aspartate-aminotransferase (AST), alanine aminotransferase (ALT) and leucine-aminopeptidase (LAP) may serve as an additional test for functional liver damage in chickens caused by gamma-ray. Fifty day old hybrid male chickens of heavy Jata breeds were irradiated by gamma-ray in the dose of 7,23±0,95 Gy. Blood samples were taken from the wing vein on days 1, 3, 5, 7, 9 and 15 after irradiation. Activity of AST, ALT, and LAP in the blood plasma were determined spectrophotometrically using Boehringer Mannheim GmbH optimized kits. At the end of the experiment all birds were sacrificed and, as well as died birds were photomorphologically and histologically investigated. The obtained results showed decrease of activity of all three enzymes during the whole period of investigation, but significant decrease showed only AST and LAP. It seems that both enzymes may serve as additional test for functional liver damage in chickens by external gamma-rays. (author)

  10. Assessment of light stability of drugs in blood and plasma.

    Science.gov (United States)

    de Vries, Ronald; Diels, Luc; Dillen, Lieve; Sips, Luc; Van Roosbroek, Dirk; Verhaeghe, Tom; Timmerman, Philip

    2016-10-01

    A procedure was developed for the assessment of photochemical stability of drugs in blood and plasma under standardized conditions. The procedure avoids a variable outcome of photochemical stability experiments and tests relevant worst case conditions so that unnecessary light protection is avoided. Results/methodology: Blood and plasma were spiked with a mixture of drugs and incubated in a Suntest CPS(+), in the laboratory on the bench and near the window on a sunny summer day. The results were compared. No protection from light, limited protection from light and full protection from light are advised for drugs that are stable in plasma in the Suntest CPS(+) at 250 W/m(2) for at least 30 min, for 5-30 min and for <5 min, respectively.

  11. A comparative evaluation of the blood clot, platelet-rich plasma, and platelet-rich fibrin in regeneration of necrotic immature permanent teeth: A clinical study

    Directory of Open Access Journals (Sweden)

    Isha Narang

    2015-01-01

    Full Text Available Introduction: This study was designed as a clinical trial to evaluate and compare the regenerative potential of platelet-rich fibrin (PRF, platelet-rich plasma (PRP, and blood clot in immature necrotic permanent teeth with or without associated apical periodontitis. Methods: Access preparation was done under rubber dam isolation. Copious irrigation was done with 2.5% NaOCl and triple antibiotic paste was placed as an intracanal medicament. After 4 weeks, the cases were divided into four groups with five patients in each group. The study design had three test arms and one control arm. Group I in which mineral trioxide aggregate apexification was carried out and it was kept as control group to evaluate the regenerative potential of blood clot and platelet concentrates, Group II in which blood clot was used as scaffold in the canal, Group III in PRF was used as scaffold, and Group IV in which PRP carried on collagen was used as a scaffold. Results: The clinical and radiographic evaluation after 6 and 18 months was done by two independent observers who were blinded from the groups. The scoring was done as: None score was denoted by, Fair by 1, Good by 2, and Excellent by 3. The data were then analyzed statistically by Fisher′s exact test using Statistics and Data 11.1(PRP Using harvest Smart PReP2 which showed statistically significant values in Group III as compared to other Groups. Conclusion: PRF has huge potential to accelerate the growth characteristics in immature necrotic permanent teeth as compared to PRP and blood clot.

  12. HPLC determination of plasma dimethylarginines: method validation and preliminary clinical application.

    Science.gov (United States)

    Ivanova, Mariela; Artusi, Carlo; Boffa, Giovanni Maria; Zaninotto, Martina; Plebani, Mario

    2010-11-11

    Asymmetric dimethylarginine (ADMA) has been suggested as a possible marker of endothelial dysfunction, and interest in its use in clinical practice is increasing. However, the potential role of symmetric dimethylarginine (SDMA) as an endogenous marker of renal function, has been less widely investigated. The aims of the present study were therefore to determine reference values for dimethylarginines in plasma after method validation, and to ascertain ADMA plasma concentrations in patients with disorders characterized by endothelial dysfunction; a further end-point was to investigate the relationship between SDMA plasma concentrations and estimated GFR (eGFR) as well as plasmatic creatinine in patients with chronic kidney disease (CKD). HPLC with fluorescence detection was used for the determination of plasma dimethylarginines. To verify the clinical usefulness of ADMA and SDMA, values from 4 groups of patients at a high risk of cardiovascular complications as well renal dysfunction (chronic heart failure n=126; type II diabetes n=43; pulmonary arterial hypertension n=17; chronic kidney disease n=42) were evaluated, and compared with the reference values, obtained from 225 blood donors. The intra- and inter-assay CVs (peadiatric populations, for which the use of eGFR is not recommended. 2010 Elsevier B.V. All rights reserved.

  13. Atmospheric Pressure Plasma Induced Sterilization and Chemical Neutralization

    Science.gov (United States)

    Garate, Eusebio; Evans, Kirk; Gornostaeva, Olga; Alexeff, Igor; Lock Kang, Weng; Wood, Thomas K.

    1998-11-01

    We are studying chemical neutralization and surface decontamination using atmospheric pressure plasma discharges. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC, AC or pulsed discharges. Results indicate that the atmospheric plasma is effective in sterilizing surfaces with biological contaminants like E-coli and bacillus subtilus cells. Exposure times of less than four minutes in an air plasma result in a decrease in live colony counts by six orders of magnitude. Greater exposure times result in a decrease of live colony counts of up to ten orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are simulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.

  14. Pulsed cold plasma-induced blood coagulation and its pilot application in stanching bleeding during rat hepatectomy

    Science.gov (United States)

    Keping, YAN; Qikang, JIN; Chao, ZHENG; Guanlei, DENG; Shengyong, YIN; Zhen, LIU

    2018-04-01

    This paper presents plasma-induced blood coagulation and its pilot application in rat hepatectomy by using a home-made pulsed cold plasma jet. Experiments were conducted on blood coagulation in vitro, the influence of plasma on tissue in vivo, and the pilot application of rat hepatectomy. Experimental results show that the cold plasma can lead to rapid blood coagulation. Compared with the control sample, the plasma-induced agglomerated layer of blood is thicker and denser, and is mostly composed of broken platelets. When the surface of the liver was treated by plasma, the influence of the plasma can penetrate into the liver to a depth of about 500 μm. During the rat hepatectomy, cold plasma was proved to be effective for stanching bleeding on incision. No obvious bleeding was found in the abdominal cavities of all six rats 48 h after the hepatectomy. This implies that cold plasma can be an effective modality to control bleeding during surgical operation.

  15. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  16. blood and plasma volumes in normal west african dwarf sheep

    African Journals Online (AJOL)

    Dr Olaleye

    volume (PCV) and haemoglobin (Hb) values were determined as descried by Benjamin (1978) using the microhaematocrit and ... Standard dye concentration of 20 mg/ml was used for determining the dye concentration in plasma. ... Haemoglobin (Hb), Plasma Volume and Blood Volume in the West African Dwarf. Sheep.

  17. Phase transitions during compression and decompression of clots from platelet-poor plasma, platelet-rich plasma and whole blood.

    Science.gov (United States)

    Liang, Xiaojun; Chernysh, Irina; Purohit, Prashant K; Weisel, John W

    2017-09-15

    Blood clots are required to stem bleeding and are subject to a variety of stresses, but they can also block blood vessels and cause heart attacks and ischemic strokes. We measured the compressive response of human platelet-poor plasma (PPP) clots, platelet-rich plasma (PRP) clots and whole blood clots and correlated these measurements with confocal and scanning electron microscopy to track changes in clot structure. Stress-strain curves revealed four characteristic regions, for compression-decompression: (1) linear elastic region; (2) upper plateau or softening region; (3) non-linear elastic region or re-stretching of the network; (4) lower plateau in which dissociation of some newly made connections occurs. Our experiments revealed that compression proceeds by the passage of a phase boundary through the clot separating rarefied and densified phases. This observation motivates a model of fibrin mechanics based on the continuum theory of phase transitions, which accounts for the pre-stress caused by platelets, the adhesion of fibrin fibers in the densified phase, the compression of red blood cells (RBCs), and the pumping of liquids through the clot during compression/decompression. Our experiments and theory provide insights into the mechanical behavior of blood clots that could have implications clinically and in the design of fibrin-based biomaterials. The objective of this paper is to measure and mathematically model the compression behavior of various human blood clots. We show by a combination of confocal and scanning electron microscopy that compression proceeds by the passage of a front through the sample that separates a densified region of the clot from a rarefied region, and that the compression/decompression response is reversible with hysteresis. These observations form the basis of a model for the compression response of clots based on the continuum theory of phase transitions. Our studies may reveal how clot rheology under large compression in vivo due

  18. Titanium nitride plasma-chemical synthesis with titanium tetrachloride raw material in the DC plasma-arc reactor

    Science.gov (United States)

    Kirpichev, D. E.; Sinaiskiy, M. A.; Samokhin, A. V.; Alexeev, N. V.

    2017-04-01

    The possibility of plasmochemical synthesis of titanium nitride is demonstrated in the paper. Results of the thermodynamic analysis of TiCl4 - H2 - N2 system are presented; key parameters of TiN synthesis process are calculated. The influence of parameters of plasma-chemical titanium nitride synthesis process in the reactor with an arc plasmatron on characteristics on the produced powders is experimentally investigated. Structure, chemical composition and morphology dependencies on plasma jet enthalpy, stoichiometric excess of hydrogen and nitrogen in a plasma jet are determined.

  19. Concentration and chemical status of arsenic in the blood of pregnant hamsters during critical embryogenesis. 1. Subchronic exposure to arsenate utilizing constant rate administration

    Energy Technology Data Exchange (ETDEWEB)

    Hanlon, D.P.; Ferm, V.H.

    1986-08-01

    The concentration, availability, and chemical status of radiolabeled arsenic has been determined in the blood of pregnant hamsters at the beginning (morning of Day 8) and the end (morning of Day 9) of the critical period of embryogenesis. Hamster dams were exposed to teratogenic doses of arsenate by means of osmotic minipumps implanted on the morning of Day 6 of the gestation period. Whole blood arsenic concentrations were the same for 48 and 72 hr postimplant. The arsenic concentration of plasma equaled that of red cells. Plasma arsenic was not bound to macromolecules and had the same chemical status 48 and 72 hr postimplant. Arsenate was the dominant form (67% of the total). However, the presence of dimethylarsinic acid and arsenite indicates that the pentavalent species was metabolized. Red cell arsenic was bound to macromolecules in the cell sap. Seventy percent of red cell sap arsenic was dialyzable 48 hr postimplant, but only 56% 72 hr postimplant. Arsenate was the dominant dialyzable red cell species on Day 8 and arsenite was the major dialyzable form on Day 9. The authors findings demonstrate a relationship between the maternal blood concentration and chemical status of arsenic and the presence of malformations resulting from a constant rate exposure of pregnant hamsters to arsenate via the osmotic minipump.

  20. Concentration and chemical status of arsenic in the blood of pregnant hamsters during critical embryogenesis. 1. Subchronic exposure to arsenate utilizing constant rate administration

    International Nuclear Information System (INIS)

    Hanlon, D.P.; Ferm, V.H.

    1986-01-01

    The concentration, availability, and chemical status of radiolabeled arsenic has been determined in the blood of pregnant hamsters at the beginning (morning of Day 8) and the end (morning of Day 9) of the critical period of embryogenesis. Hamster dams were exposed to teratogenic doses of arsenate by means of osmotic minipumps implanted on the morning of Day 6 of the gestation period. Whole blood arsenic concentrations were the same for 48 and 72 hr postimplant. The arsenic concentration of plasma equaled that of red cells. Plasma arsenic was not bound to macromolecules and had the same chemical status 48 and 72 hr postimplant. Arsenate was the dominant form (67% of the total). However, the presence of dimethylarsinic acid and arsenite indicates that the pentavalent species was metabolized. Red cell arsenic was bound to macromolecules in the cell sap. Seventy percent of red cell sap arsenic was dialyzable 48 hr postimplant, but only 56% 72 hr postimplant. Arsenate was the dominant dialyzable red cell species on Day 8 and arsenite was the major dialyzable form on Day 9. The authors findings demonstrate a relationship between the maternal blood concentration and chemical status of arsenic and the presence of malformations resulting from a constant rate exposure of pregnant hamsters to arsenate via the osmotic minipump

  1. BOVINE PLASMA FIBRINOGEN AS MARKER IN CLINICAL AND SUB-CLINICAL MASTITIS

    Directory of Open Access Journals (Sweden)

    R. Ali

    2018-06-01

    Full Text Available Plasma samples were collected from healthy as well as clinical and sub-clinical mastitis affected cows from Barasat, West Bengal, India. Plasma samples, after ammonium sulphate precipitation, were dialyzed against several changes of PBS (pH 7.2 to remove the excess ammonium sulphate. Then plasma fibrinogens were purified by gel filtration chromatography on Sephacryl S-200 HR. SDS-PAGE (10% of purified fibrinogen from plasma of healthy cow revealed polypeptide bands of 74, 67 and 57 kDa which represent the α (alpha, β (beta and γ (gamma- chains respectively. On the other hand, purified fibrinogen from plasma of sub-clinical and clinical mastitis affected cow revealed polypeptide bands of 73 (α-chain, 68 kDa (β-chain and 72 (γ-chain, 68 kDa (β-chain respectively. The SDS-PAGE analysis showed the absence of gamma (γ- chain of fibrinogen in both the samples of sub-clinical and clinical mastitis positive cow. Single precipitin line was observed in double immunodiffusion test when purified fibrinogen from healthy, clinical and subclinical mastitis positive cows reacted with hyper immune sera raised in rabbit. No precipitin line was found against the normal control serum. These purified fibrinogens also showed cross reactivity against antibody raised in rabbit when analyzed by western blot technique.

  2. Study on the changes in blood plasma electroconductivity and dielectric constant in irradiated mammals

    International Nuclear Information System (INIS)

    Paskalev, Z.; Bancheva, E.

    1975-01-01

    Blood plasma electroconductivity and dielectric constant were measured in C57BL mice exposed to an uncontaminated gamma or neutron field or a mixed gamma-neutron field at a total dose of 5, 10, 15, 20, or 25 rad. Measurements were also made with blood plasma from Wistar rats given 200, 400, or 600 R X-rays. The results obtained revealed a characteristic pattern of radiation-induced changes in electroconductivity and dielectric constant, these end-points being indicative, respectively, or shifts in saline concentrations and in conformation of protein fractions of blood plasma. Analysis of the data showed that within a few days after exposure there were changes occurring in cellular and tissue water-salt metabolism, followed by enhancement or recovery to norm, depending on the dose. A possibility is thus rendered to use the blood plasma parameters studied as a test for detecting early shifts in cellular water-salt metabolism and in conformation of protein fractions at a time when no characteristic changes are yet to be observed in amounts of individual types of protein fractions from blood plasma of irradiated organisms. (author)

  3. Viable Bacteria Associated with Red Blood Cells and Plasma in Freshly Drawn Blood Donations

    DEFF Research Database (Denmark)

    Damgaard, Christian; Magnussen, Karin; Enevold, Christian

    2015-01-01

    ) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. SETTING: Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. PARTICIPANTS: 60 donors (≥50 years old....... CONCLUSIONS: Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing......OBJECTIVES: Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from...

  4. Polarized Raman spectroscopic characterization of normal and oral cancer blood plasma

    Science.gov (United States)

    Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan

    2017-02-01

    In India oral cancer ranks the top due to the habitual usage of tobacco in its various forms and remains the major burden. Hence priority is given for early diagnosis as it is the better solution for cure or to improve the survival rate. For the past three decades, optical spectroscopic techniques have shown its capacity in the discrimination of normal and malignant samples. Many research works have conventional Raman in the effective detection of cancer using the variations in bond vibrations of the molecules. However in addition polarized Raman provides the orientation and symmetry of biomolecules. If so can polarized Raman be the better choice than the conventional Raman in the detection of cancer? The present study aimed to found the answer for the above query. The conventional and polarized Raman spectra were acquired for the same set of blood plasma samples of normal subjects and oral malignant (OSCC) patients. Thus, obtained Raman spectral data were compared using linear discriminant analysis coupled with artificial neural network (LDA-ANN). The depolarization ratio of biomolecules such as antioxidant, amino acid, protein and nucleic acid bases present in blood plasma was proven to be the best attributes in the categorization of the groups. The polarized Raman results were promising in discriminating oral cancer blood plasma from that of normal blood plasma with improved efficiency. The results will be discussed in detail.

  5. A high confidence, manually validated human blood plasma protein reference set

    DEFF Research Database (Denmark)

    Schenk, Susann; Schoenhals, Gary J; de Souza, Gustavo

    2008-01-01

    BACKGROUND: The immense diagnostic potential of human plasma has prompted great interest and effort in cataloging its contents, exemplified by the Human Proteome Organization (HUPO) Plasma Proteome Project (PPP) pilot project. Due to challenges in obtaining a reliable blood plasma protein list......-trap-Fourier transform (LTQ-FT) and a linear ion trap-Orbitrap (LTQ-Orbitrap) for mass spectrometry (MS) analysis. Both instruments allow the measurement of peptide masses in the low ppm range. Furthermore, we employed a statistical score that allows database peptide identification searching using the products of two...... consecutive stages of tandem mass spectrometry (MS3). The combination of MS3 with very high mass accuracy in the parent peptide allows peptide identification with orders of magnitude more confidence than that typically achieved. RESULTS: Herein we established a high confidence set of 697 blood plasma proteins...

  6. Role of red cells and plasma composition on blood sessile droplet evaporation

    Science.gov (United States)

    Lanotte, Luca; Laux, Didier; Charlot, Benoît; Abkarian, Manouk

    2017-11-01

    The morphology of dried blood droplets derives from the deposition of red cells, the main components of their solute phase. Up to now, evaporation-induced convective flows were supposed to be at the base of red cell distribution in blood samples. Here, we present a direct visualization by videomicroscopy of the internal dynamics in desiccating blood droplets, focusing on the role of cell concentration and plasma composition. We show that in diluted suspensions, the convection is promoted by the rich molecular composition of plasma, whereas it is replaced by an outward red blood cell displacement front at higher hematocrits. We also evaluate by ultrasounds the effect of red cell deposition on the temporal evolution of sample rigidity and adhesiveness.

  7. [Isolation and characterization of exosomes from blood plasma of breast cancer and colorectal cancer patients].

    Science.gov (United States)

    Tamkovich, S N; Yunusova, N V; Stakheeva, М N; Somov, A K; Frolova, А Y; Kirushina, N А; Afanasyev, S G; Grigoryeva, А E; Laktionov, P P; Kondakova, I V

    2017-03-01

    A simple approach for isolation of exosomes from the blood plasma, which allows to obtain highly purified preparations of microvesicles no larger than 100 nm has been proposed. The presence of different subpopulations of exosomes in the blood plasma of healthy donors and cancer patients has been recognized. We found the presence of the universal markers CD9, CD24 and CD81 on exosomes isolated from blood plasma that can be used to their routine typing.

  8. A clinical governance framework for blood services.

    Science.gov (United States)

    Williamson, L M; Benjamin, R J; Devine, D V; Katz, L M; Pink, J

    2015-05-01

    The elements of clinical governance, which ensure excellence in clinical care, can be applied to blood services. In this survey, their application in a range of blood providers was gauged, with the aim of identifying best practice and producing a generalizable framework. The Medical Directors of members of the Alliance of Blood Operators surveyed how different elements of clinical governance operated within their organizations and developed recommendations applicable in the blood service environment. The recommendations that emerged highlighted the importance of an organization's culture, with the delivery of optimal clinical governance being a corporate responsibility. Senior management must agree and promote a set of values to ensure that the system operates with the patient and donor at its heart. All staff should understand how their role fits into the 'journey to the patient', and a culture of openness promoted. Thus, reporting of errors and risks should be actively sought and praised, with penalties applied for concealment. Systems should exist to collect, analyse and escalate clinical outcomes, safety data, clinical risk assessments, incident reports and complaints to inform organizational learning. Clinical governance principles from general health care can be applied within blood services to complement good manufacturing practice. This requires leadership, accountability, an open culture and a drive for continuous improvement and excellence in clinical care. © 2015 International Society of Blood Transfusion.

  9. The Chemical Potential of Plasma Membrane Cholesterol: Implications for Cell Biology.

    Science.gov (United States)

    Ayuyan, Artem G; Cohen, Fredric S

    2018-02-27

    Cholesterol is abundant in plasma membranes and exhibits a variety of interactions throughout the membrane. Chemical potential accounts for thermodynamic consequences of molecular interactions, and quantifies the effective concentration (i.e., activity) of any substance participating in a process. We have developed, to our knowledge, the first method to measure cholesterol chemical potential in plasma membranes. This was accomplished by complexing methyl-β-cyclodextrin with cholesterol in an aqueous solution and equilibrating it with an organic solvent containing dissolved cholesterol. The chemical potential of cholesterol was thereby equalized in the two phases. Because cholesterol is dilute in the organic phase, here activity and concentration were equivalent. This equivalence allowed the amount of cholesterol bound to methyl-β-cyclodextrin to be converted to cholesterol chemical potential. Our method was used to determine the chemical potential of cholesterol in erythrocytes and in plasma membranes of nucleated cells in culture. For erythrocytes, the chemical potential did not vary when the concentration was below a critical value. Above this value, the chemical potential progressively increased with concentration. We used standard cancer lines to characterize cholesterol chemical potential in plasma membranes of nucleated cells. This chemical potential was significantly greater for highly metastatic breast cancer cells than for nonmetastatic breast cancer cells. Chemical potential depended on density of the cancer cells. A method to alter and fix the cholesterol chemical potential to any value (i.e., a cholesterol chemical potential clamp) was also developed. Cholesterol content did not change when cells were clamped for 24-48 h. It was found that the level of activation of the transcription factor STAT3 increased with increasing cholesterol chemical potential. The cholesterol chemical potential may regulate signaling pathways. Copyright © 2018. Published by

  10. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  11. Prospects of Vitamin C as an Additive in Plasma of Stored Blood

    Directory of Open Access Journals (Sweden)

    R. Vani

    2015-01-01

    Full Text Available There is a dire necessity to improve blood storage and prolong shelf-life of blood. Very few studies have focused on oxidative stress (OS in blood and its influence on plasma with storage. This study attempts to (i elucidate the continuous changes occurring in plasma during storage through oxidant levels and antioxidant status and (ii evaluate the influence of vitamin C (VC as an additive during blood storage. Blood was drawn from male Wistar rats and stored for 25 days at 4°C. Blood samples were divided into control and experimental groups. Plasma was isolated every 5 days and the OS markers, antioxidant enzymes, lipid peroxidation, and protein oxidation products, were studied. Catalase activity increased in all groups with storage. Lipid peroxidation decreased in VC (10 but was maintained in VC (30 and VC (60. Although there were variations in all groups, carbonyls were maintained towards the end of storage. Advanced oxidation protein products (AOPP increased in VC (30 and were maintained in VC (10 and VC (60. Sulfhydryls were maintained in all groups. Vitamin C could not sufficiently attenuate OS and hence, this opens the possibilities for further studies on vitamin C in combination with other antioxidants, in storage solutions.

  12. Serial changes in plasma K concentration during storage of irradiation blood products

    International Nuclear Information System (INIS)

    Togashi, Kazue; Yamada, Keiko; Otake, Sachiko; Saito, Yukiko; Sugimura, Kazuhito; Takahashi, Hoyu

    1996-01-01

    Irradiation of blood products is highly effective in the prevention of transfusion-associated graft-versus-host disease (GVHD). In order to assess the safe storage period of irradiated blood products, serial changes in plasma K, red cell 2,3-diphosphoglycerate (2,3-DPG) and lactic acid concentrations of whole blood and M·A·P-added red cell concentrate (RC-M·A·P) during storage at 5degC were measured after irradiation with 137 Cs by IBL 437C (CIS bio international). Plasma K concentration did not change immediately after irradiation, but increased more rapidly and in a radiation dose-dependent manner in the irradiated products than nonirradiated products. The changes in red cell 2,3-DPG and lactic acid concentrations were not affected by irradiation but were rather dependent on the storage period after blood collection. Plasma K concentrations of whole blood and RC-M·A·P irradiated with 25 Gy increased at 5 and 3 days, respectively, to the K levels observed after the storage of nonirradiated products for 21 days. It is therefore recommended that whole blood be used within 5 days and RC-M·A·P within 3 days when stored after irradiation with 25 Gy. (author)

  13. Plasma concentrations of soluble urokinase-type plasminogen activator receptor are increased in patients with malaria and are associated with a poor clinical or a fatal outcome

    DEFF Research Database (Denmark)

    Ostrowski, Sisse R; Ullum, Henrik; Goka, Bamenla Q

    2005-01-01

    PAR are associated with disease severity in malaria. METHODS: At admission to the hospital, plasma concentrations of suPAR were measured by ELISA in samples from 645 African children with clinical symptoms of malaria: 478 had malaria, and 167 had a blood film negative for Plasmodium parasites. Fourteen healthy......BACKGROUND: Blood concentrations of soluble urokinase-type plasminogen activator receptor (suPAR) are increased in conditions with immune activation, and high concentrations of suPAR often predict a poor clinical outcome. This study explored the hypothesis that high plasma concentrations of su......: If the plasma concentration of suPAR reflects the extent of parasite-induced immune activation, this may explain why a high concentration of suPAR is associated with a poor clinical outcome in patients with malaria....

  14. Dialyzer-augmented whole blood and plasma exchange for patients with hepatic or hepatorenal failure.

    Science.gov (United States)

    Buselmeier, T J; Merino, G E; Rodrigo, F; Meyer, R M; Bosl, B H; Kjellstrand, C M; Simmons, R L; Najarian, J S

    1975-01-01

    We have utilized new methods of dialyzer-augmented whole blood and plasma exchange tranfusion in the treatment of hepatic coma. The method employs the new fast flow Buselmeier shunt so that the exchange can be done from a peripheral radial artery shunt site rather than a shunt site in a more major vessel, such as the brachial artery. The method employs in-line dialysis of citrated (CPD) blood or plasma to normalize pH, electrolytes, and blood sugar while infusion heparinization decreases heparin requirements. The application of a single roller pump to the administration and withdrawal lines (placed in opposite directions) helps equalize inflow and outflow where whole blood exchange is done while identical opposing pumps accomplish the same with plasma exchange. The administration of albumin and metaraminol bitartate prevents hypotension due to fluid shifts or compartmental venous dilatation. A closed circuit which does not require disconnection throughout the 30- 60-minute whole blood exchange or the 2 1/2-hour plasma exchange decreases the risk of septic contamination to both medical staff and patients.

  15. Discriminating the hemolytic risk of blood type A plasmas using the complement hemolysis using human erythrocytes (CHUHE) assay.

    Science.gov (United States)

    Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L

    2017-03-01

    The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.

  16. Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma

    Directory of Open Access Journals (Sweden)

    Kazunori Murata

    2018-02-01

    Full Text Available The objective of this study was to examine the analytical performance of 14 comprehensive metabolic panel analytes on the Abaxis Piccolo Xpress® Point of Care analyzer in serum, plasma, and whole blood. A method comparison was performed on all three specimen types intended for use on the Piccolo Xpress®: serum, heparinized plasma, and whole blood. This data is also presented in Murata et al. (2015 [1]. This article includes the actual Bland-Altman bias plots of the difference in results obtained for analytes in the comprehensive metabolic panel from the Abaxis Piccolo Xpress and the comparison instrument, the Ortho Vitros. Keywords: Clinical chemistry, Point-of care testing

  17. Plasma free hemoglobin and microcirculatory response to fresh or old blood transfusions in sepsis.

    Directory of Open Access Journals (Sweden)

    Elisa Damiani

    Full Text Available Free hemoglobin (fHb may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected.This is a secondary analysis of a randomized study. Twenty adult septic patients received either fresh or old (15 days storage, respectively RBC transfusions. fHb was measured in RBC units and in the plasma before and 1 hour after transfusion. Simultaneously, the sublingual microcirculation was assessed with sidestream-dark field imaging. The perfused boundary region was calculated as an index of glycocalyx damage. Tissue oxygen saturation (StO2 and Hb index (THI were measured with near-infrared spectroscopy and a vascular occlusion test was performed.Similar fHb levels were found in the supernatant of fresh and old RBC units. Despite this, plasma fHb increased in the old RBC group after transfusion (from 0.125 [0.098-0.219] mg/mL to 0.238 [0.163-0.369] mg/mL, p = 0.006. The sublingual microcirculation was unaltered in both groups, while THI increased. The change in plasma fHb was inversely correlated with the changes in total vessel density (r = -0.57 [95% confidence interval -0.82, -0.16], p = 0.008, De Backer score (r = -0.63 [95% confidence interval -0.84, -0.25], p = 0.003 and THI (r = -0.72 [95% confidence interval -0.88, -0.39], p = 0.0003.Old RBC transfusion was associated with an increase in plasma fHb in septic patients. Increasing plasma fHb levels were associated with decreased microvascular density.ClinicalTrials.gov NCT01584999.

  18. Contaminating fibrin in CPD-blood: solubility in plasma and distribution in blood components following separation

    International Nuclear Information System (INIS)

    Skjonsberg, O.H.; Kierulf, P.; Gravem, K.; Fagerhol, M.K.; Godal, H.C.

    1986-01-01

    In order to estimate the solubility of contaminating fibrin in CPD-blood, thrombin induced fibrin polymerzation in CPD-plasma was examined by light scattering and fibrinopeptide A (FPA) determinations. In addition, I-125 fibrin monomer enriched CPD-blood was used to investigate fibrin monomer retention in blood bags and transfusion filters (170 microns) and fibrin distribution in blood components derived from CPD-blood. Initial fibrin polymerization in CPD-blood occurred after conversion of 15 per cent of the fibrinogen to fibrin, implying that substantial amounts of fibrin may be kept solubilized in CPD-blood bags. Only minor amounts of I-125 fibrin monomers were retained in blood bags (2.4 per cent) and in transfusion filters (2.9 per cent) after sham transfusions. After separating I-125-fibrin monomer enriched CPD-blood into its constituent components, the major part of fibrin (75.0 per cent) could be traced in the cryoprecipitate

  19. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  20. Reduced chemical warfare agent sorption in polyurethane-painted surfaces via plasma-enhanced chemical vapor deposition of perfluoroalkanes.

    Science.gov (United States)

    Gordon, Wesley O; Peterson, Gregory W; Durke, Erin M

    2015-04-01

    Perfluoralkalation via plasma chemical vapor deposition has been used to improve hydrophobicity of surfaces. We have investigated this technique to improve the resistance of commercial polyurethane coatings to chemicals, such as chemical warfare agents. The reported results indicate the surface treatment minimizes the spread of agent droplets and the sorption of agent into the coating. The improvement in resistance is likely due to reduction of the coating's surface free energy via fluorine incorporation, but may also have contributing effects from surface morphology changes. The data indicates that plasma-based surface modifications may have utility in improving chemical resistance of commercial coatings.

  1. Fundamental aspects of plasma chemical physics transport

    CERN Document Server

    Capitelli, Mario; Laricchiuta, Annarita

    2013-01-01

    Fundamental Aspects of Plasma Chemical Physics: Tranpsort develops basic and advanced concepts of plasma transport to the modern treatment of the Chapman-Enskog method for the solution of the Boltzmann transport equation. The book invites the reader to consider actual problems of the transport of thermal plasmas with particular attention to the derivation of diffusion- and viscosity-type transport cross sections, stressing the role of resonant charge-exchange processes in affecting the diffusion-type collision calculation of viscosity-type collision integrals. A wide range of topics is then discussed including (1) the effect of non-equilibrium vibrational distributions on the transport of vibrational energy, (2) the role of electronically excited states in the transport properties of thermal plasmas, (3) the dependence of transport properties on the multitude of Saha equations for multi-temperature plasmas, and (4) the effect of the magnetic field on transport properties. Throughout the book, worked examples ...

  2. Power law relation between particle concentrations and their sizes in the blood plasma

    International Nuclear Information System (INIS)

    Kirichenko, M N; Chaikov, L L; Zaritskii, A R

    2016-01-01

    This work is devoted to the investigation of sizes and concentrations of particles in blood plasma by dynamic light scattering (DLS). Blood plasma contains many different proteins and their aggregates, microparticles and vesicles. Their sizes, concentrations and shapes can give information about donor's health. Our DLS study of blood plasma reveals unexpected dependence: with increasing of the particle sizes r (from 1 nm up to 1 μm), their concentrations decrease as r -4 (almost by 12 orders). We found also that such dependence was repeated for model solution of fibrinogen and thrombin with power coefficient is -3,6. We believe that this relation is a fundamental law of nature that shows interaction of proteins (and other substances) in biological liquids. (paper)

  3. Influence of Chemical Precleaning on the Plasma Treatment Efficiency of Aluminum by RF Plasma Pencil

    Czech Academy of Sciences Publication Activity Database

    Prysiazhnyi, V.; Slavíček, P.; Mikmeková, Eliška; Klíma, M.

    2016-01-01

    Roč. 18, č. 4 (2016), s. 430-437 ISSN 1009-0630 Institutional support: RVO:68081731 Keywords : atmospheric pressure plasma * plasma jet * aluminium * surface treatment * surface processing * chemical precleaning Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.830, year: 2016

  4. [Demography and donation frequencies of blood and plasma donor populations in Germany].

    Science.gov (United States)

    Ritter, Sabine; Willand, L; Reinhard, B; Offergeld, R; Hamouda, O

    2008-08-01

    According to Article 22 of the Transfusion Act, the Robert Koch Institute collects and evaluates nationwide data on the prevalence and incidence of transfusion-relevant infections among blood and plasma donors in Germany. Due to revision of the Transfusion Act in 2005 not only the number of donations but also the number of donors has become available for analysis. Here we give a detailed account on the demographic profile and donation frequencies of German whole blood, plasma and platelet donors in 2006. Overall, 4 % of the German population eligible to donate were active as repeat whole blood donors in 2006; 0.3 % repeatedly donated plasma or platelets. Irrespective of the type of donation, the percentage of donors among the general population was highest among the youngest age group (18 to 24 years). While the age distribution of whole blood repeat donors roughly resembled that of the general population, with the greatest number among those aged 35 to 44, younger age groups were overrepresented among repeat plasma donors. Donation frequency varied depending on donor age and sex, with an average of 1.9 per year for whole blood donations, 11.9 for plasmapheresis and 4.0 for plateletpheresis. With the exception of the latter, men donated more frequently than women. For both sexes, donation frequency increased with age. Detailed knowledge of the demographic profile and changes in the composition of donor populations are essential for planning adequate blood supply. The data presented may serve as reference for assessing the consequences of measures that affect the number of donors and/or donations (for example changing deferral criteria) in Germany.

  5. The effect of heat- or ultra violet ozone-treatment of titanium on complement deposition from human blood plasma.

    Science.gov (United States)

    Linderbäck, Paula; Harmankaya, Necati; Askendal, Agneta; Areva, Sami; Lausmaa, Jukka; Tengvall, Pentti

    2010-06-01

    Titanium (Ti) is a well known metallic biomaterial extensively used in dental, orthopaedic-, and occasionally also in blood contacting applications. It integrates well to bone and soft tissues, and is shown upon blood plasma contact to activate the intrinsic pathway of coagulation and bind complement factor 3b. The material properties depend largely on those of the nm-thick dense layer of TiO(2) that becomes rapidly formed upon contact with air and water. The spontaneously formed amorphous Ti-oxide has a pzc approximately 5-6 and its water solubility is at the order of 1-2 micromolar. It is often subjected to chemical- and heat treatments in order to increase the anatase- and rutile crystallinity, to modify the surface topography and to decrease the water solubility. In this work, we prepared sol-gel derived titanium and smooth PVD titanium surfaces, and analysed their oxide and protein deposition properties in human blood plasma before and after annealing at 100-500 degrees C or upon UVO-treatment for up to 96 hours. The blood plasma results show that complement deposition vanished irreversibly after heat treatment at 250-300 degrees C for 30 minutes or after UVO exposure for 24 hours or longer. XPS and infrared spectroscopy indicated change of surface water/hydroxyl binding upon the heat- and UVO treatments, and increased Ti oxidation. XRD analysis confirmed an increased crystallinity and both control (untreated) and annealed smooth titanium displayed low XRD-signals indicating some nanocrystallinity, with predominantly anatase phase. The current results show that the behaviour of titanium dioxide in blood contact can be controlled through relatively simple means, such as mild heating and illumination in UV-light, which both likely irreversibly change the stoichiometry and structure of the outmost layers of titanium dioxide and its OH/H(2)O binding characteristics. (c) 2010 Elsevier Ltd. All rights reserved.

  6. Digitalis-like activity in human plasma: Relation to blood pressure and sodium balance

    Energy Technology Data Exchange (ETDEWEB)

    Goto, A.; Yamada, K.; Ishii, M.; Sugimoto, T. (Univ. of Tokyo (Japan))

    1990-10-01

    PURPOSE: On the assumption that renal tubular cells are more important as the target cells for a natriuretic factor than blood cells, we used a well-characterized cultured renal tubular cell line, Madin-Darby canine kidney (MDCK), cells to monitor the circulating digitalis-like factor in human plasma and examine its role in the regulation of blood pressure and sodium balance. SUBJECTS AND METHODS: We investigated the effects of plasma on binding of radioactive ouabain to monolayered MDCK cells in order to determine the level of a circulating digitalis-like factor. First, we measured specific 3H-ouabain binding to MDCK cells in the presence of plasma from 71 outpatients (34 normotensive subjects and 37 hypertensive patients) after incubation for 4 hours. Second, we measured specific 3H-ouabain binding after incubation of cells with plasma from 16 hospitalized subjects (eight normotensive subjects and eight hypertensive patients) receiving low and high sodium diets. RESULTS: In Study 1, ouabain binding was lower by 30% with plasma from hypertensive patients than with plasma from normotensive subjects (p less than 0.01). There was a significant negative correlation between individual subject's systolic or mean blood pressure and ouabain binding (r = -0.34, p less than 0.01 or r = -0.29, p less than 0.01). In Study 2, ouabain binding was also significantly reduced by 25% in the presence of plasma from hypertensive subjects as compared with plasma from normotensive subjects irrespective of sodium intake (p less than 0.01). A significant negative correlation was also found for all subjects between either systolic, diastolic, or mean blood pressure and ouabain binding (r = -0.58, p less than 0.01, r = -0.51, p less than 0.01, or r = -0.55, p less than 0.01, respectively).

  7. Determination of telmisartan in human blood plasma: Part I: Immunoassay development

    NARCIS (Netherlands)

    Hempen, C.M.; Gläsle-Schwarz, Liane; Kunz, Ulrich; Karst, U.

    2006-01-01

    Telmisartan is an angiotensin II receptor antagonist and a known drug against high blood pressure. In this report, the development of a new and rapid analytical technique, an enzyme-linked immunosorbent assay (ELISA) for the determination of telmisartan in human blood plasma is described. The

  8. Effects of imipramine of the orthostatic changes in blood pressure, heart rate and plasma catecholamines

    DEFF Research Database (Denmark)

    Nielsen, J R; Johansen, Torben; Arentoft, A

    1983-01-01

    The effect of imipramine on the orthostatic changes in heart rate, blood pressure and plasma catecholamines were examined in six healthy male subjects on two occasions on high sodium balance (Na+ excretion greater than 120 mmol per day) and on low sodium balance (Na+ excretion less than 110 mmol...... per day), respectively. Orthostatic tests were carried out before and 2 h after ingestion of 150 mg imipramine hydrochloride. Imipramine caused a moderate increase in supine systolic blood pressure, and a pronounced increase in the rise in heart rate, when the subjects assumed erect position....... The orthostatic drop in systolic blood pressure was in most cases only moderately increased after ingestion of imipramine, but in three subjects pronounced orthostatic hypotension developed when the sodium balance was low, whereas no clinical symptoms were seen in the same subjects when tested after imipramine...

  9. The influence of blood plasma of irradiated animals on activity of Ca2+ - ATPase and Mg2+ - ATPase in plasma membrane of thymocytes

    International Nuclear Information System (INIS)

    Dreval', V.I.

    1994-01-01

    Rats were irradiated at doses 1.5, 4.0, 7.0 and 10 Gy. After 1, 8, 15, 22 and 30 days the effect of blood plasma on activity of Ca 2+ -ATPase and Mg 2+ -ATPase in plasma membrane of thymocytes was investigated. It was found that the raise of irradiation dose leads to increasing of blood plasma effect on membrane-bound enzymes

  10. Plasma fractionation, a useful means to improve national transfusion system and blood safety: Iran experience.

    Science.gov (United States)

    Cheraghali, A M; Abolghasemi, H

    2009-03-01

    In 1974, the government of Iran established Iranian Blood Transfusion Organization (IBTO) as national and centralized transfusion system. Since then donations of blood may not be remunerated and therapy with blood and its components are free of charges for all Iranian patients. Donations are meticulously screened through interviewing donors and lab testing the donations using serological methods. Currently, Iranian donors donate 1735 00 units of blood annually (donation index: 25/1000 population). Implementation of a highly efficient donor selection programme, including donors interview, establishment of confidential unit exclusion programme and laboratory screening of donated bloods by IBTO have led to seroprevalence rates of 0.41%, 0.12% and 0.004% for HBV, HCV and HIV in donated bloods respectively. Since 2004, IBTO has initiated a programme to enter into a contract fractionation agreement for the surplus of recovered plasma produced in its blood collecting centres. Although IBTO has used this project as a mean to improve national transfusion system through upgrading its quality assurance systems, IBTO fractionation project has played a major role in improving availability of plasma-derived medicines in Iran. During 2006-2007, this project furnished the Iran market with 44% and 14% of its needs to the intravenous immunoglobulin and albumin, respectively. Iranian experience showed that contract fractionation of plasma in countries with organized centralized transfusion system, which lack national plasma fractionation facility, in addition to substantial saving on national health resource and enhancing availability of plasma-derived medicines, could serve as a useful means to improve national blood safety profile.

  11. Studies of single-walled carbon nanotubes-induced hepatotoxicity by NMR-based metabonomics of rat blood plasma and liver extracts

    Science.gov (United States)

    Lin, Bencheng; Zhang, Huashan; Lin, Zhiqing; Fang, Yanjun; Tian, Lei; Yang, Honglian; Yan, Jun; Liu, Huanliang; Zhang, Wei; Xi, Zhuge

    2013-05-01

    The toxicological effects of single-walled carbon nanotubes (SWCNTs) were investigated after intratracheal instillation in male Wistar rats over a 15-day period using metabonomic analysis of 1H (nuclear magnetic resonance) NMR spectra of blood plasma and liver tissue extracts. Concurrent liver histopathology examinations and plasma clinical chemistry analyses were also performed. Significant changes were observed in clinical chemistry features, including alkaline phosphatase, total protein, and total cholesterol, and in liver pathology, suggesting that SWCNTs clearly have hepatotoxicity in the rat. 1H NMR spectra and pattern recognition analyses from nanomaterial-treated rats showed remarkable differences in the excretion of lactate, trimethylamine oxide, bilineurin, phosphocholine, amylaceum, and glycogen. Indications of amino acid metabolism impairment were supported by increased lactate concentrations and decreased alanine concentrations in plasma. The rise in plasma and liver tissue extract concentrations of choline and phosphocholine, together with decreased lipids and lipoproteins, after SWCNTs treatment indicated a disruption of membrane fluidity caused by lipid peroxidation. Energy, amino acid, and fat metabolism appeared to be affected by SWCNTs exposure. Clinical chemistry and metabonomic approaches clearly indicated liver injury, which might have been associated with an indirect mechanism involving nanomaterial-induced oxidative stress.

  12. Erythrocyte sedimentation rate and fibrinogen concentration of whole blood influences the cellular composition of platelet-rich plasma obtained from centrifugation methods.

    Science.gov (United States)

    Yin, Wenjing; Xu, Zhengliang; Sheng, Jiagen; Xie, Xuetao; Zhang, Changqing

    2017-09-01

    Erythrocyte sedimentation rate (ESR), which reflects the sedimentation rate of platelets, leukocytes and erythrocytes in response to centrifugal force, may influence the cellular composition of platelet-rich plasma (PRP) obtained via centrifugation methods. However, no relevant studies have substantiated this. In the present study, blood was collected from 40 healthy volunteers and used to prepare PRP with two plasma-based preparation systems [YinPRP and Plasma Rich in Growth Factor (PRGF) systems] and two buffy coat-based systems (RegenPRP and WEGOPRP systems) in a single-donor model. Volumes of PRP and platelet-poor plasma (PPP) that were removed in the preparation process were recorded. Analyses of ESR, haematocrit, C-reaction protein, coagulation, serum glucose and serum lipid of the whole blood used for PRP preparation were performed to evaluate the levels of ESR and the factors known to influence it. Whole blood analysis was performed to evaluate the cellular composition of PRP. Results demonstrated that there were marked positive correlations between the ESR of the whole blood used for PRP preparation and PPP removal efficiencies, platelet concentrations, platelet capture efficiencies and platelet enrichment factors of PRP formulations obtained from plasma-based systems, and PRP yield efficiency of RegenPRP and PPP removal efficiency of WEGOPRP. Furthermore, there were marked negative correlations between ESR and concentrations and enrichment factors of platelets, leukocytes and erythrocytes of RegenPRP. Fibrinogen concentration of the whole blood, which had a marked positive correlation with ESR, also influenced the cellular composition of PRP. These findings may increase the understanding of PRP preparation and provide substantial evidence for the individualised optimisation of PRP preparation systems used in clinical practice.

  13. Concordance of mutation detection in circulating tumor DNA in early clinical trials using different blood collection protocols

    DEFF Research Database (Denmark)

    Ahlborn, Lise B.; Madsen, Mette; Jonson, Lars

    2017-01-01

    in a clinical setting. Here we investigate the concordance between standard blood collection for molecular analysis using immediate separation of plasma, compared to the use of collection tubes allowing for delayed processing. Methods: In this study, we measured the fractional abundance of tumor specific...... patients with advanced solid cancers enrolled in early clinical trials. Results: Concordance in the fractional abundance of mutations in ctDNA isolated from blood collected in either K3EDTA or BCT tubes from patients with different solid cancers was observed. Conclusions: This study indicates that BCT...... mutations (BRAF p.V600E and PIK3CA p.H1047R) in ctDNA isolated from blood samples collected in either cell-stabilizing Cell-Free DNA BCT tubes (delayed processing within 72 hours) or standard K3EDTA tubes (immediate processing within 15 minutes). Twenty-five blood sample pairs (EDTA/BCT) were collected from...

  14. A centrifuge-less plasma separation method from whole blood anticoagulated with EDTA-2K for the use of clinical laboratory tests.

    Science.gov (United States)

    Tatsumi, N; Tsuda, I; Fukumori, T; Hino, M; Takubo, T; Kondo, H

    2001-12-01

    In the modern medical laboratory system, simple and rapid processing of specimens are required. In the current system with the transportation line, its centrifugation part would disturb smooth flow of the testing because it needs much time for the centrifugation. To solve the problems, a serum separation method was tried for the whole blood specimen using poly-L-lysine, concanavalin A and phyto-hemoagglutinin. Ploy-L-lysine with molecular weight 130,000 to 210,000 in a final concentration of 0.1% could accelerate blood sedimentation, although its supernatant contaminated platelets. Concanavalin and phytohemoagulutinin could accelerate the sedimentation and obtained plasma, but the method could yield enough amount of supernatant by 1 hour standing. As the purpose of this study is to develop a centrifugeless method, a sieve method using a steel mesh and a magnet was applied to the mixture of EDTA blood, red-cell adhesives and thrombin. The method was unique to separate plasma, but the yield was not so high and chemistry data were not fitted with serum data in some of tests. Thus, the trial would be a new technology, but it was judged that some further improvement will be needed technically.

  15. A continuous flow micro filtration device for plasma/blood separation using submicron vertical pillar gap structures

    International Nuclear Information System (INIS)

    Kang, Tae Goo; Ji, Hongmiao; Lim, Pei Yi; Chen, Yu; Yoon, Yong-Jin

    2014-01-01

    This work demonstrates a continuous flow plasma/blood separator using a vertical submicron pillar gap structure. The working principle of the proposed separator is based on size exclusion of cells through cross-flow filtration, in which only plasma is allowed to pass through submicron vertical pillars located tangential to the main flow path of the blood sample. The maximum filtration efficiency of 99.9% was recorded with a plasma collection rate of 0.67 µl min −1 for an input blood flow rate of 12.5 µl min −1 . The hemolysis phenomenon was observed for an input blood flow rate above 30 µl min −1 . Based on the experimental results, we can conclude that the proposed device shows potential for the application of on-chip plasma/blood separation as a part of integrated point-of-care (POC) diagnostics systems. (technical note)

  16. Relative Abundance of Proteins in Blood Plasma Samples from Patients with Chronic Cerebral Ischemia.

    Science.gov (United States)

    Kaysheva, Anna L; Kopylov, Artur T; Ponomarenko, Elena A; Kiseleva, Olga I; Teryaeva, Nadezhda B; Potapov, Alexander A; Izotov, Alexander А; Morozov, Sergei G; Kudryavtseva, Valeria Yu; Archakov, Alexander I

    2018-03-01

    A comparative protein profile analysis of 17 blood plasma samples from patients with ischemia and 20 samples from healthy volunteers was carried out using ultra-high resolution mass spectrometry. The analysis of measurements was performed using the proteomics search engine OMSSA. Normalized spectrum abundance factor (NSAF) in the biological samples was assessed using SearchGUI. The findings of mass spectrometry analysis of the protein composition of blood plasma samples demonstrate that the depleted samples are quite similar in protein composition and relative abundance of proteins. By comparing them with the control samples, we have found a small group of 44 proteins characteristic of the blood plasma samples from patients with chronic cerebral ischemia. These proteins contribute to the processes of homeostasis maintenance, including innate immune response unfolding, the response of a body to stress, and contribution to the blood clotting cascade.

  17. Chemical analysis of plasma-assisted antimicrobial treatment on cotton

    International Nuclear Information System (INIS)

    Kan, C W; Lam, Y L; Yuen, C W M; Luximon, A; Lau, K W; Chen, K S

    2013-01-01

    This paper explores the use of plasma treatment as a pretreatment process to assist the application of antimicrobial process on cotton fabric with good functional effect. In this paper, antimicrobial finishing agent, Microfresh Liquid Formulation 9200-200 (MF), and a binder (polyurethane dispersion, Microban Liquid Formulation R10800-0, MB) will be used for treating the cotton fabric for improving the antimicrobial property and pre-treatment of cotton fabric by plasma under atmospheric pressure will be employed to improve loading of chemical agents. The chemical analysis of the treated cotton fabric will be conducted by Fourier transform Infrared Spectroscopy.

  18. Inhibitors of serotonin reuptake and specific imipramine binding in human blood plasma

    International Nuclear Information System (INIS)

    Brusov, O.S.; Fomenko, A.M.; Katasonov, A.B.; Lidemann, R.R.

    1985-01-01

    This paper describes a method of extraction of endogenous inhibitors of specific IMI binding and of 5-HT reuptake, from human blood plasma and the heterogeneity of these compounds is demonstrated. Specific binding was determined as the difference between binding of 3 H-IMI in the absence and in the presence of 50 microM IMI. Under these conditions, specific binding amounted to 70-80% of total binding of 3 H-IMI. It is shown that extract obtained from human blood contains a material which inhibits dose-dependently both 5-HT reuptake and specific binding of 3 H-IMI. Gel-chromatography of extracts of human blood plasma on Biogel P-2 is also shown

  19. Quantitative evaluation of plasma after methylene blue and white light treatment in four Chinese blood centers.

    Science.gov (United States)

    Chunhui, Yang; Guohui, Bian; Hong, Yang; Xiaopu, Xiao; Zherong, Bai; Mingyuan, Wang; Xinsheng, Zhang; Juanjuan, Wang; Changqing, Li; Wuping, Li

    2013-12-01

    Pathogen reduction technology is an important process in the blood safety system, including solvent/detergent treatment, filtration and methylene blue-photochemical technology (MB-PCT). To investigate the quality of MB-PCT-treated plasma, plasma samples from four Chinese blood centers were analyzed over 12 months of storage to determine the recovery of activities and levels of various plasma proteins. Ten plasma units each from the Suzhou, Yancheng, Chongqing and Shandong blood centers were divided into two aliquots. One was subjected to treatment with one of two methylene blue-photochemical technology instruments and the other was used as control. The treated and untreated sample pairs were stored at -30°C. The recovery rates of coagulation factors, inhibitor proteins, total protein, immunoglobulins, and complement proteins were measured at different time points after storage. The mean recovery of most proteins exceeded 80% after MB treatment. The exceptions were factor XI and fibrinogen, of which only 71.3-74% and 69.0-92.3% were retained during storage. The two equipment types differed in terms of residual MB concentration in the plasma samples (0.18 μM and 0.29 μM, respectively). They had similar protein recovery rates at 0.5 month but differed at later time points. The four blood centers differed significantly with regard to factor II, V, VIII and fibrinogen activities. Only the samples from the Shandong blood center met the methylene blue treated fresh frozen plasma requirement. The major factor that influenced the quality of the MB-FFP samples was the time taken between blood collection and storage. Methylene blue treated plasma showed reduced coagulation factor (CF) activity and protein levels. The MB treatment-induced damage to the proteins was acceptable at the four Chinese blood centers, but the quality of the MB-treated plasma in general was not satisfactory. The main factor affecting plasma quality may be the duration of the collection and

  20. Impact of Ficoll density gradient centrifugation on major and trace element concentrations in erythrocytes and blood plasma.

    Science.gov (United States)

    Lu, Ying; Ahmed, Sultan; Harari, Florencia; Vahter, Marie

    2015-01-01

    Ficoll density gradient centrifugation is widely used to separate cellular components of human blood. We evaluated the suitability to use erythrocytes and blood plasma obtained from Ficoll centrifugation for assessment of elemental concentrations. We determined 22 elements (from Li to U) in erythrocytes and blood plasma separated by direct or Ficoll density gradient centrifugation, using inductively coupled plasma mass spectrometry. Compared with erythrocytes and blood plasma separated by direct centrifugation, those separated by Ficoll had highly elevated iodine and Ba concentration, due to the contamination from the Ficoll-Paque medium, and about twice as high concentrations of Sr and Mo in erythrocytes. On the other hand, the concentrations of Ca in erythrocytes and plasma were markedly reduced by the Ficoll separation, to some extent also Li, Co, Cu, and U. The reduced concentrations were probably due to EDTA, a chelator present in the Ficoll medium. Arsenic concentrations seemed to be lowered by Ficoll, probably in a species-specific manner. The concentrations of Mg, P, S, K, Fe, Zn, Se, Rb, and Cs were not affected in the erythrocytes, but decreased in plasma. Concentrations of Mn, Cd, and Pb were not affected in erythrocytes, but in plasma affected by EDTA and/or pre-analytical contamination. Ficoll separation changed the concentrations of Li, Ca, Co, Cu, As, Mo, I, Ba, and U in erythrocytes and blood plasma, Sr in erythrocytes, and Mg, P, S, K, Fe, Zn, Se, Rb and Cs in blood plasma, to an extent that will invalidate evaluation of deficiencies or excess intakes. Copyright © 2014 Elsevier GmbH. All rights reserved.

  1. [Effectiveness of different methods of blood separation in performing plasma- and cytapheresis].

    Science.gov (United States)

    Ryzhko, V V; Gorodetskiĭ, V M; Rogova, E M

    1988-01-01

    Obtaining of a therapeutic dose of platelets from donors, necessary to stop spontaneous hemorrhage and sufficient enough to correct hemostasis in surgical interventions in patients with amegakaryocytic thrombocytopenia, therapeutic plasmapheresis with the removal of 1.5-2.01 of plasma, effective erythrocytapheresis can be done with the help of refrigerator centrifuges and plastic containers. This method can be also employed for effective leukocytapheresis in patients with the leukocyte level exceeding 100.10(9)/l. It is simple, economical, reliable; several donors (patients) can be involved in the procedure at a time. Blood cell separators can be most effectively used for therapeutic lymphocytoplasmapheresis, massive plasmapheresis with the removal of over 2.51 of plasma, for obtaining a large number of platelets and granulocytes. The CS-3000 blood cell separator ensures automatic control over blood separation and possible complications during a procedure; a constant temperature regimen of blood separation; one-time use of equipment in direct contact with patient's (donor's) blood; a high efficacy and safety of the procedure.

  2. The influence of platelets, plasma and red blood cells on functional haemostatic assays

    DEFF Research Database (Denmark)

    Bochsen, Louise; Johansson, Pär I.; Kristensen, Annemarie Thuri

    2011-01-01

    concentrates, fresh frozen plasma and stored RBC. Pure platelets were investigated by removing plasma components from platelet concentrates by diafiltration against the platelet storage solution Intersol. Plasma was readded by diafiltration against plasma in Intersol. Haemostatic function was evaluated by TEG...... plasma from platelet concentrates eliminated the TEG response and diminished the Multiplate aggregation response, but readding plasma to the pure platelet concentrates restored the response. Each of the elements in whole blood, plasma, platelets and RBC, affected the Multiplate and TEG results...

  3. Time-resolved resonance fluorescence spectroscopy for study of chemical reactions in laser-induced plasmas.

    Science.gov (United States)

    Liu, Lei; Deng, Leimin; Fan, Lisha; Huang, Xi; Lu, Yao; Shen, Xiaokang; Jiang, Lan; Silvain, Jean-François; Lu, Yongfeng

    2017-10-30

    Identification of chemical intermediates and study of chemical reaction pathways and mechanisms in laser-induced plasmas are important for laser-ablated applications. Laser-induced breakdown spectroscopy (LIBS), as a promising spectroscopic technique, is efficient for elemental analyses but can only provide limited information about chemical products in laser-induced plasmas. In this work, time-resolved resonance fluorescence spectroscopy was studied as a promising tool for the study of chemical reactions in laser-induced plasmas. Resonance fluorescence excitation of diatomic aluminum monoxide (AlO) and triatomic dialuminum monoxide (Al 2 O) was used to identify these chemical intermediates. Time-resolved fluorescence spectra of AlO and Al 2 O were used to observe the temporal evolution in laser-induced Al plasmas and to study their formation in the Al-O 2 chemistry in air.

  4. Effects of biometrics, location and persistent organic pollutants on blood clinical-chemical parameters in polar bears (Ursus maritimus) from Svalbard, Norway.

    Science.gov (United States)

    Ciesielski, Tomasz Maciej; Sonne, Christian; Ormbostad, Ingunn; Aars, Jon; Lie, Elisabeth; Bytingsvik, Jenny; Jenssen, Bjørn Munro

    2018-05-31

    In the present study, blood clinical-chemical parameters (BCCPs) were analysed in 20 female and 18 male Svalbard polar bears (Ursus maritimus) captured in spring 2007. The aim was to study how age, body condition (BC), biometrics, plasma lipid content and geographical location may confound the relationship between persistent organic pollutants (POPs) including PCBs, HCB, chlordanes, DDTs, HCHs, mirex and OH-PCBs and the concentrations of 12 specific BCCPs (hematocrit [HCT], hemoglobin [HB], aspartate aminotransferase [ASAT], alanine aminotransferase [ALAT], γ-glutamyltransferase [GGT], creatine kinase [CK], triglycerides [TG], cholesterol [CHOL], high-density lipoprotein [HDL], creatinine (CREA], urea, potassium (K]), and to investigate if any of these BCCPs may be applied as potential biomarkers for POP exposure in polar bears. Initial PCA and O-PLS modelling showed that age, lipids, BC and geographical location (longitude and latitude) were important parameters explaining BCCPs in females. Following subsequent partial correlation analyses correcting for age and lipids, multiple POPs in females were still significantly correlated with HCT and HDL (all p biometrics, lipids and longitude in males, multiple POPs were significantly correlated with HCT, ASAT, GGT and CHOL (all p < 0.05). In conclusion, several confounding parameters has to be taken into account when studying the relations between BCCPs and POPs in polar bears. When correcting for these, in particular HCT may be used as a simple cost-efficient biomarker of POP exposure in polar bears. Furthermore, decreasing HDL concentrations and increasing CHOL concentration with increasing POP concentrations may indicate responses related to increased risk of cardiovascular disease. We therefore suggest to further study POP exposure and lipidome response to increase knowledge of the risk of cardiometabolic syndrome in polar bears. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Applying chemical engineering concepts to non-thermal plasma reactors

    Science.gov (United States)

    Pedro AFFONSO, NOBREGA; Alain, GAUNAND; Vandad, ROHANI; François, CAUNEAU; Laurent, FULCHERI

    2018-06-01

    Process scale-up remains a considerable challenge for environmental applications of non-thermal plasmas. Undersanding the impact of reactor hydrodynamics in the performance of the process is a key step to overcome this challenge. In this work, we apply chemical engineering concepts to analyse the impact that different non-thermal plasma reactor configurations and regimes, such as laminar or plug flow, may have on the reactor performance. We do this in the particular context of the removal of pollutants by non-thermal plasmas, for which a simplified model is available. We generalise this model to different reactor configurations and, under certain hypotheses, we show that a reactor in the laminar regime may have a behaviour significantly different from one in the plug flow regime, often assumed in the non-thermal plasma literature. On the other hand, we show that a packed-bed reactor behaves very similarly to one in the plug flow regime. Beyond those results, the reader will find in this work a quick introduction to chemical reaction engineering concepts.

  6. Blood and plasma volumes in normal west African dwarf sheep ...

    African Journals Online (AJOL)

    Blood and plasma volumes were determined using T-1824 in 36 normal adult West African Dwarf sheep. In the rams, dry ewes, pregnant ewes and lactating ewes, the mean values for the blood volume (ml/kg body weight) were 64.08 ± 6.11, 55.74 ± 9.31, 71.46 ± 6.46 and 147.12 ± 12.79 respectively, while the mean values ...

  7. Altering plasma sodium concentration rapidly changes blood pressure during haemodialysis.

    Science.gov (United States)

    Suckling, Rebecca J; Swift, Pauline A; He, Feng J; Markandu, Nirmala D; MacGregor, Graham A

    2013-08-01

    Plasma sodium is increased following each meal containing salt. There is an increasing interest in the effects of plasma sodium concentration, and it has been suggested that it may have direct effects on blood pressure (BP) and possibly influences endothelial function. Experimental increases of plasma sodium concentration rapidly raise BP even when extracellular volume falls. Ten patients with end-stage renal failure established on haemodialysis were studied during the first 2 h of dialysis without fluid removal during this period. They were randomized to receive haemodialysis with (i) dialysate sodium concentration prescribed to 135 mmol/L and (ii) 145 mmol/L in random order in a prospective, single-blinded crossover study. BP measurements and blood samples were taken every 30 min. Pre-dialysis sitting BP was 137/76 ± 7/3 mmHg. Lower dialysate sodium concentration (135 mmol/L) reduced plasma sodium concentration [139.49 ± 0.67 to 135.94 ± 0.52 mmol/L (P area under the curve (AUC) 15823.50 ± 777.15 (mmHg)min] compared with 145 mmol/L [AUC 17018.20 ± 1102.17 (mmHg)min], mean difference 1194.70 ± 488.41 (mmHg)min, P < 0.05. There was a significant positive relationship between change in plasma sodium concentration and change in systolic BP. This direct relationship suggests that a fall of 1 mmol/L in plasma sodium concentration would be associated with a 1.7 mmHg reduction in systolic BP (P < 0.05). The potential mechanism for the increase in BP seen with salt intake may be through small but significant changes in plasma sodium concentration.

  8. Clinical Outcomes of a Pharmacy-Led Blood Factor Stewardship Program.

    Science.gov (United States)

    Trueg, Anne O; Lowe, Christopher; Kiel, Patrick J

    To report the results of a pharmacist-directed blood factor stewardship program targeting off-label utilization designed to limit use to established organizational guidelines in high-risk populations. Prospective evaluation of recombinant factor VIIa and prothrombin complex concentrate orders beginning June 2013 through May 2014 and a matched retrospective cohort from June 2012 to May 2013. Matched cohorts were evaluated for 28-day mortality, change in international normalized ratio (INR), adverse events, concurrent blood product use, and cost savings. Forty-two orders for blood factor were ordered between June 2013 and May 2014, 70 orders in the year before (N = 112). Twenty eight-day mortality was not different between the cohorts: 53.9% versus 50% (P = 0.77). Blood factor use with underlying liver failure and active bleeding was strongly associated with 28-day mortality: odds ratio (95% confidence interval), 2.9 (1.5-7.14) and 2.91 (0.01-2.91), respectively. Blood products dispensed increased over the year with plasma products the most significant (1 vs. 4 P = 0.004). All other clinical outcomes were nonsignificant. An annual cost savings of $375,539 was achieved, primarily through a significant reduction in recombinant factor VIIa and avoidance in high-risk patients. Use of off-label blood factors can be controlled through a pharmacist-led stewardship program. Twenty eight-day mortality was not different between the 2 cohorts; however, identification of risk factors for death associated with blood factor use allows for restriction in high-risk populations, creates a discussion of futile care, and yields cost savings.

  9. Microfluidic Devices for Blood Fractionation

    Directory of Open Access Journals (Sweden)

    Chwee Teck Lim

    2011-07-01

    Full Text Available Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. Microfluidics is an attractive solution for this application leveraging its numerous advantages to process clinical blood samples. This paper reviews the various microfluidic approaches realized to successfully fractionate one or more blood components. Techniques to separate plasma from hematologic cellular components as well as isolating blood cells of interest including certain rare cells are discussed. Comparisons based on common separation metrics including efficiency (sensitivity, purity (selectivity, and throughput will be presented. Finally, we will provide insights into the challenges associated with blood-based separation systems towards realizing true point-of-care (POC devices and provide future perspectives.

  10. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  11. Relationships of Whole Blood Serotonin and Plasma Norepinephrine within Families.

    Science.gov (United States)

    Leventhal, Bennett L.; And Others

    1990-01-01

    This study of 47 families of autistic probands found that whole blood serotonin was positively correlated between autistic children and their mothers, fathers, and siblings, but plasma norepinephrine levels were not. (Author/JDD)

  12. Molecular typing for blood group antigens within 40 minutes by direct PCR from plasma or serum

    Science.gov (United States)

    Wagner, Franz Friedrich; Flegel, Willy Albert; Bittner, Rita; Döscher, Andrea

    2016-01-01

    Determining blood group antigens by serological methods may be unreliable in certain situations, such as in patients after chronic or massive transfusion. Red cell genotyping offers a complementary approach, but current methods may take much longer than conventional serological typing, limiting their utility in urgent situations. To narrow this gap, we devised a rapid method using direct polymerase chain reaction (PCR) amplification while avoiding the DNA extraction step. DNA was amplified by PCR directly from plasma or serum of blood donors followed by a melting curve analysis in a capillary rapid-cycle PCR assay. We evaluated the single nucleotide polymorphisms underlying the clinically relevant Fya, Fyb, Jka and Jkb antigens, with our analysis being completed within 40 min of receiving a plasma or serum sample. The positive predictive value was 100% and the negative predictive value at least 84%. Direct PCR with melting point analysis allowed faster red cell genotyping to predict blood group antigens than any previous molecular method. Our assay may be used as a screening tool with subsequent confirmatory testing, within the limitations of the false-negative rate. With fast turnaround times, the rapid-cycle PCR assay may eventually be developed and applied to red cell genotyping in the hospital setting. PMID:27991657

  13. Blood plasma separation in ZnO nanoflowers-supported paper based microfluidic for glucose sensing

    Science.gov (United States)

    Muhimmah, Luthviyah Choirotul; Roekmono, Hadi, Harsono; Yuwono, Rio Akbar; Wahyuono, Ruri Agung

    2018-04-01

    Blood plasma separation is essential to analyze and quantify the bio-substances in the human blood and hence, allows for diagnosing various diseases. This paper presents the two layer paper-based microfluidic analytical devices coated with ZnO nanoflowers (ZnO NF-µPAD) for a rapid blood plasma separation and glucose sensing. Plasma separation in ZnO NF-µPAD was evaluated experimentally and numerically using computational fluid dynamics package for a flow over porous networks. Glucose detection was carried out using Fourier-transform infrared (FTIR) measurements. The glucose concentrations in the red blood samples investigated here vary in the range of 150 - 310 mg.dl-1. The plasma separation process on ZnO NF-μPAD requires 240 ± 93 s. The spectroscopic data reveals that the IR absorptions and Raman signals at the typical vibrational frequencies of glucose are increasing at higher glucose concentration. After subtraction from absorption background arising from ZnO NF and the paper, linearly increasing IR absorption (913 and 1349 cm-1) and Raman signals (1346 and 1461 cm-1) are observable with a relatively good sensitivity.

  14. Passive blood plasma separation at the microscale: a review of design principles and microdevices

    International Nuclear Information System (INIS)

    Tripathi, Siddhartha; Varun Kumar, Y V Bala; Joshi, Suhas S; Agrawal, Amit; Prabhakar, Amit

    2015-01-01

    Blood plasma separation is vital in the field of diagnostics and health care. Due to the inherent advantages obtained in the transition to microscale, the recent trend in these fields is a rapid shift towards the miniaturization of complex macro processes. Plasma separation in microdevices is one such process which has received extensive attention from researchers globally. Blood plasma separation techniques based on microfluidic platforms can be broadly classified into two categories. While active techniques utilize external force fields for separation, the passive techniques are dependent on biophysical effects, cell behavior, hydrodynamic forces and channel geometry for blood plasma separation. In general, passive separation methods are favored in comparison to active methods because they tend to avoid design complexities and are relatively easy to integrate with biosensors; additionally they are cost effective. Here we review passive separation techniques demonstrating separation and blood behavior at microscale. We present an extensive review of relevant biophysical laws, along with experimental details of various passive separation techniques and devices exploiting these physical effects. The relative performances, and the advantages and disadvantages of microdevices discussed in the literature, are compared and future challenges are brought about. (topical review)

  15. [Prospects in blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-04-01

    What will be the evolution of blood transfusion in the next 10 years? What are the scientific and medical arguments to help the decision makers to propose the developments? Many scientific and clinical studies show that blood substitutes are not ready for use in man. So, for a long time, blood collection in man will still be a necessity to prepare cell concentrates (red blood cells and platelets) and fresh frozen plasma. During this period, blood safety will be based on development of testing technics and preparation processes of blood products. Another major point will be a better clinical use of blood derivates. Cellular therapy will be probably only a way of diversification in blood transfusion centers in partnership with hospitals.

  16. Lipoperoxides, alpha-tocopherol and ceruloplasmin in gamma-irradiated blood plasma

    International Nuclear Information System (INIS)

    Aladzhov, E.; Popzakharieva, V.

    1995-01-01

    Ceruloplasmin, alpha-tocopherol and lipid peroxide concentrations are evaluated in blood plasma for transfusion following exposure to irradiation with 60 Co gamma rays at doses 23, 50, 100 and 200 Gy. In plasma exposed to irradiation an increase in lipid peroxides and decrease in alpha-tocopherol and ceruloplasmin are observed. The addition of 2.3 U/ml ceruloplasmin to plasma prior to irradiation reduces the quantity of lipid peroxides and protects alpha-tocopherol. The possible explanation is that the metal helates prevent the formation of free hydroxyl radicals and thus inhibit the oxidation of lipid membranes. 15 refs., 1 tab. (author)

  17. Fundamental limits on gas-phase chemical reduction of NOx in a plasma

    Energy Technology Data Exchange (ETDEWEB)

    Penetrante, B.M.; Hsiao, M.C.; Merritt, B.T.; Vogtlin, G.E. [Lawrence Livermore National Lab., CA (United States)

    1997-12-31

    In the plasma, the electrons do not react directly with the NOx molecules. The electrons collide mainly with the background gas molecules like N{sub 2}, O{sub 2} and H{sub 2}O. Electron impact on these molecules result partly in dissociation reactions that produce reactive species like N, O and OH. The NOx in the engine exhaust gas initially consist mostly of NO. The ground state nitrogen atom, N, is the only species that could lead to the chemical reduction of NO to N{sub 2}. The O radical oxidizes NO to NO{sub 2} leaving the same amount of NOx. The OH radical converts NO{sub 2} to nitric acid. Acid products in the plasma can easily get adsorbed on surfaces in the plasma reactor and in the pipes. When undetected, the absence of these oxidation products can often be mistaken for chemical reduction of NOx. In this paper the authors will examine the gas-phase chemical reduction of NOx. They will show that under the best conditions, the plasma can chemically reduce 1.6 grams of NOx per brake-horsepower-hour [g(NOx)/bhp-hr] when 5% of the engine output energy is delivered to the plasma.

  18. Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

    International Nuclear Information System (INIS)

    Lee, Hye W.; Lee, Jong K.; Park, Ki Y.

    2009-01-01

    Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was 61 .deg. . The contact angles of chemical etched, plasma treated or both were improved to the range of 15∼33 .deg. . In the case of electroless plating, the thickest layer without blister was 1.6 μm. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were 75 kgf/cm 2 , 102 kgf/cm 2 , 113 kgf/cm 2 , respectively, comparing to the 24 kgf/cm 2 of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times

  19. Detection of melanoma cells suspended in mononuclear cells and blood plasma using photoacoustic generation

    Science.gov (United States)

    Spradling, Emily M.; Viator, John A.

    2009-02-01

    Melanoma is the deadliest form of skin cancer. Although the initial malignant cells are removed, it is impossible to determine whether or not the cancer has metastasized until a secondary tumor forms that is large enough to detect with conventional imaging. Photoacoustic detection of circulating melanoma cells in the bloodstream has shown promise for early detection of metastasis that may aid in treatment of this aggressive cancer. When blood is irradiated with energy from an Nd:YAG laser at 532 nm, photoacoustic signals are created and melanoma cells can be differentiated from the surrounding cells based on waveforms produced by an oscilloscope. Before this can be used as a diagnostic technique, however, we needed to investigate several parameters. Specifically, the current technique involves the in vitro separation of blood through centrifugation to isolate and test only the white blood cell layer. Using this method, we have detected a single cultured melanoma cell among a suspension of white blood cells. However, the process could be made simpler if the plasma layer were used for detection instead of the white blood cell layer. This layer is easier to obtain after blood separation, the optical difference between plasma and melanoma cells is more pronounced in this layer than in the white blood cell layer, and the possibility that any stray red blood cells could distort the results is eliminated. Using the photoacoustic apparatus, we detected no melanoma cells within the plasma of whole blood samples spiked with cultured melanoma cells.

  20. Evaluation of the overnight hold of whole blood at room temperature, before component processing: platelets (PLTs) from PLT-rich plasma.

    Science.gov (United States)

    van der Meer, Pieter F; Cancelas, Jose A; Vassallo, Ralph R; Rugg, Neeta; Einarson, Mindy; Hess, John R

    2011-01-01

    Whole blood (WB) must be refrigerated within 8 hours to optimize Factor VIII: C yield, but chilled platelets (PLTs) are rapidly removed from circulation and cannot be used clinically. It is logistically preferable to hold WB overnight at room temperature for next-day processing. We compared in vitro quality of PLT-rich plasma (PRP)-derived PLT concentrates (PCs) from fresh versus overnight-held WB. Four units of WB were pooled and split to prevent donor-dependent differences. One unit was processed immediately; three others were held at room temperature and processed after 24 to 26 hours. After soft-spin centrifugation, PRP was separated from the red blood cells. PRP was hard-spun to make PLT-poor plasma, and the PLTs were resuspended in approximately 60 mL of plasma and stored for 7 days (n = 8 paired experiments by two blood centers). After overnight hold, the PLT concentration was 1.37 × 10(9) ± 0.19 × 10(9) /mL versus 1.03 × 10(9) ± 0.32 × 10(9) /mL for freshly prepared PCs (p < 0.05). pH and glucose were significantly lower and lactate higher for overnight-held units on Day 1, but by Day 5, the differences had disappeared. Hypotonic shock response was initially better, 73 ± 14% for overnight-held versus 53 ± 12% for freshly processed (p < 0.001), but this difference also disappeared during storage. Activation marker CD62P was not different. In vitro storage conditions produce immediate differences after preparation, which disappear throughout storage. PCs from overnight-held WB have similar in vitro variables as from freshly processed WB. These findings warrant confirmation in clinical trials, but underscore the possibility of use of these PCs as being equivalent to those obtained from freshly processed WB. © 2010 American Association of Blood Banks.

  1. Hemocompatible control of sulfobetaine-grafted polypropylene fibrous membranes in human whole blood via plasma-induced surface zwitterionization.

    Science.gov (United States)

    Chen, Sheng-Han; Chang, Yung; Lee, Kueir-Rarn; Wei, Ta-Chin; Higuchi, Akon; Ho, Feng-Ming; Tsou, Chia-Chun; Ho, Hsin-Tsung; Lai, Juin-Yih

    2012-12-21

    In this work, the hemocompatibility of zwitterionic polypropylene (PP) fibrous membranes with varying grafting coverage of poly(sulfobetaine methacrylate) (PSBMA) via plasma-induced surface polymerization was studied. Charge neutrality of PSBMA-grafted layers on PP membrane surfaces was controlled by the low-pressure and atmospheric plasma treatment in this study. The effects of grafting composition, surface hydrophilicity, and hydration capability on blood compatibility of the membranes were determined. Protein adsorption onto the different PSBMA-grafted PP membranes from human fibrinogen solutions was measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Blood platelet adhesion and plasma clotting time measurements from a recalcified platelet-rich plasma solution were used to determine if platelet activation depends on the charge bias of the grafted PSBMA layer. The charge bias of PSBMA layer deviated from the electrical balance of positively and negatively charged moieties can be well-controlled via atmospheric plasma-induced interfacial zwitterionization and was further tested with human whole blood. The optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and keeps its original blood-inert property of antifouling, anticoagulant, and antithrmbogenic activities when it comes into contact with human blood. This work suggests that the hemocompatible nature of grafted PSBMA polymers by controlling grafting quality via atmospheric plasma treatment gives a great potential in the surface zwitterionization of hydrophobic membranes for use in human whole blood.

  2. Plasma-Lyte 148: A clinical review

    Science.gov (United States)

    Weinberg, Laurence; Collins, Neil; Van Mourik, Kiara; Tan, Chong; Bellomo, Rinaldo

    2016-01-01

    AIM To outline the physiochemical properties and specific clinical uses of Plasma-Lyte 148 as choice of solution for fluid intervention in critical illness, surgery and perioperative medicine. METHODS We performed an electronic literature search from Medline and PubMed (via Ovid), anesthesia and pharmacology textbooks, and online sources including studies that compared Plasma-Lyte 148 to other crystalloid solutions. The following keywords were used: “surgery”, “anaesthesia”, “anesthesia”, “anesthesiology”, “anaesthesiology”, “fluids”, “fluid therapy”, “crystalloid”, “saline”, “plasma-Lyte”, “plasmalyte”, “hartmann’s”, “ringers” “acetate”, “gluconate”, “malate”, “lactate”. All relevant articles were accessed in full. We summarized the data and reported the data in tables and text. RESULTS We retrieved 104 articles relevant to the choice of Plasma-Lyte 148 for fluid intervention in critical illness, surgery and perioperative medicine. We analyzed the data and reported the results in tables and text. CONCLUSION Plasma-Lyte 148 is an isotonic, buffered intravenous crystalloid solution with a physiochemical composition that closely reflects human plasma. Emerging data supports the use of buffered crystalloid solutions in preference to saline in improving physicochemical outcomes. Further large randomized controlled trials assessing the comparative effectiveness of Plasma-Lyte 148 and other crystalloid solutions in measuring clinically important outcomes such as morbidity and mortality are needed. PMID:27896148

  3. Pathogen reduction of blood components.

    Science.gov (United States)

    Solheim, Bjarte G

    2008-08-01

    , but not licensed by the FDA), while the method of Riboflavin light treatment of plasma still is under development. In addition to pathogen reduction the methods, however, result in some reduction of coagulation factor activity. For platelets only Psoralen and Riboflavin light treatment have been implemented. Both are CE marked products in Europe but only approved for clinical trials in the USA. The methods affect platelet activity, but result in clinically acceptable platelets with only slightly reduced CCI and increased demand for platelet transfusions. Pathogen reduction of red blood cells with FRALE (S-303) or INACTINE (PEN110) has so far resulted in the formation of antibodies against neo-epitopes on red blood cells. A promising method for Riboflavin treatment of red blood cells is under development. This manuscript reviews the current experience and discusses future trends.

  4. Development of bio/blood compatible polypropylene through low pressure nitrogen plasma surface modification

    International Nuclear Information System (INIS)

    Gomathi, N.; Rajasekar, R.; Babu, R. Rajesh; Mishra, Debasish; Neogi, S.

    2012-01-01

    Surface modification of polypropylene by nitrogen containing plasma was performed in this work in order to improve the wettability which resulted in enhanced biocompatibility and blood compatibility. Various nitrogen containing functional groups as well as oxygen containing functional groups were found to be incorporated to the polymer surface during plasma treatment and post plasma reaction respectively. Wettability of the polymers was evaluated by static contact angle measurement to show the improvement in hydrophilicity of plasma treated polypropylene. Cross linking and surface modification were reported to be dominating in the case of nitrogen plasma treatment compared to degradation. The effect of various process variables namely power, pressure, flow rate and treatment time on surface energy and weight loss was studied at various levels according to the central composite design of response surface methodology (RSM). Except pressure the other variables resulted in increased weight loss due to etching whereas with increasing pressure weight loss was found to increase and then decrease. The effect of process variables on surface morphology of polymers was evaluated by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Well spread fibroblast cells on nitrogen plasma treated polypropylene due to the presence of CO, NH 2+ and NH + was observed. Reduced platelet adhesion and increased partial thromboplastin time evidenced the increased blood compatibility. - Highlights: ► Improved biocompatibility and blood compatibility of polypropylene. ► Nitrogen plasma surface modification. ► Maintaining a balance between polar group incorporation and weight loss due to etching. ► Optimization of process conditions by response surface methodology.

  5. Measurement of Epstein-Barr virus DNA loads in whole blood and plasma by TaqMan PCR and in peripheral blood lymphocytes by competitive PCR.

    Science.gov (United States)

    Wadowsky, Robert M; Laus, Stella; Green, Michael; Webber, Steven A; Rowe, David

    2003-11-01

    Epstein-Barr virus (EBV) DNA load values were measured in samples of whole blood (n = 60) and plasma (n = 59) by TaqMan PCR and in samples of peripheral blood lymphocytes (PBLs) (n = 60) by competitive PCR (cPCR). The samples were obtained from 44 transplant recipients. The whole-blood and PBL loads correlated highly (r(2) > 0.900), whereas the plasma and PBL loads correlated poorly (r(2) = 0.512). Testing of whole blood by TaqMan PCR is an acceptable alternative to testing of PBLs by cPCR for quantifying EBV DNA load.

  6. Improvement in the performance of external quality assessment in Korean HIV clinical laboratories using unrecalcified human plasma.

    Science.gov (United States)

    Wang, Jin-Sook; Kee, Mee-Kyung; Choi, Byeong-Sun; Kim, Chan-Wha; Kim, Hyon-Suk; Kim, Sung Soon

    2012-01-01

    The external quality assessment schemes (EQAS) organizer provides a suitable program to monitor and improve the quality of human immunodeficiency virus (HIV) testing laboratories with EQAS panels prepared under various conditions. The aim of the current study was to investigate the effects of human plasma samples on the EQAS results of HIV obtained from hospital-based clinical laboratories. From 2007 to 2009, HIV EQAS panels consisted of four to six samples that consisted of undiluted positive and negative samples and were provided to laboratories twice per year. Up until the first half EQAS in 2008, EQAS panel materials were obtained by converting acid citrate dextrose treated plasma to serum via chemical treatment with CaCl2. Beginning with the second EQAS in 2008, all materials were prepared without the defibrination process. Approximately 300 HIV clinical laboratories participated in this program. The overall performance of clinical laboratories was shown to be improved when using unrecalcified plasma panels compared with recalcified panels. Significant differences were observed in EIA analyses of plasma for both positive (plaboratories.

  7. Comparison between human cord blood serum and platelet-rich plasma supplementation for Human Wharton's Jelly Stem Cells and dermal fibroblasts culture

    Directory of Open Access Journals (Sweden)

    Hashemi SS

    2016-08-01

    Full Text Available We carried out a side-by-side comparison of the effects of Human cord blood serum (HcbS versus embryonic PRP on Human Wharton's Jelly Stem Cells(hWMSCand dermal fibroblasts proliferation. Human umbilical cord blood was collected to prepare activated serum (HCS and platelet-rich plasma (CPRP.Wharton's Jelly Stem Cells and dermal fibroblasts were cultured in complete medium with10% CPRP, 10%HCSor 10% fetal bovine serumand control (serum-free media.The efficiency of the protocols was evaluated in terms of the number of adherent cells and their expansion and Cell proliferation. We showed that proliferation of fibroblasts and mesenchymal stem cells in the presence of cord blood serum and platelet-rich plasma significantly more than the control group (p≤0/05. As an alternative to FBS, cord blood serum has been proved as an effective component in cell tissue culture applications and embraced a vast future in clinical applications of regenerative medicine. However, there is still a need to explore the potential of HCS and its safe applications in humanized cell therapy or tissue engineering.

  8. Health Technology Assessment of pathogen reduction technologies applied to plasma for clinical use

    Science.gov (United States)

    Cicchetti, Americo; Berrino, Alexandra; Casini, Marina; Codella, Paola; Facco, Giuseppina; Fiore, Alessandra; Marano, Giuseppe; Marchetti, Marco; Midolo, Emanuela; Minacori, Roberta; Refolo, Pietro; Romano, Federica; Ruggeri, Matteo; Sacchini, Dario; Spagnolo, Antonio G.; Urbina, Irene; Vaglio, Stefania; Grazzini, Giuliano; Liumbruno, Giancarlo M.

    2016-01-01

    Although existing clinical evidence shows that the transfusion of blood components is becoming increasingly safe, the risk of transmission of known and unknown pathogens, new pathogens or re-emerging pathogens still persists. Pathogen reduction technologies may offer a new approach to increase blood safety. The study is the output of collaboration between the Italian National Blood Centre and the Post-Graduate School of Health Economics and Management, Catholic University of the Sacred Heart, Rome, Italy. A large, multidisciplinary team was created and divided into six groups, each of which addressed one or more HTA domains. Plasma treated with amotosalen + UV light, riboflavin + UV light, methylene blue or a solvent/detergent process was compared to fresh-frozen plasma with regards to current use, technical features, effectiveness, safety, economic and organisational impact, and ethical, social and legal implications. The available evidence is not sufficient to state which of the techniques compared is superior in terms of efficacy, safety and cost-effectiveness. Evidence on efficacy is only available for the solvent/detergent method, which proved to be non-inferior to untreated fresh-frozen plasma in the treatment of a wide range of congenital and acquired bleeding disorders. With regards to safety, the solvent/detergent technique apparently has the most favourable risk-benefit profile. Further research is needed to provide a comprehensive overview of the cost-effectiveness profile of the different pathogen-reduction techniques. The wide heterogeneity of results and the lack of comparative evidence are reasons why more comparative studies need to be performed. PMID:27403740

  9. Discrepant fibrinolytic response in plasma and whole blood during experimental endotoxemia in healthy volunteers.

    Directory of Open Access Journals (Sweden)

    Sisse R Ostrowski

    Full Text Available Sepsis induces early activation of coagulation and fibrinolysis followed by late fibrinolytic shutdown and progressive endothelial damage. The aim of the present study was to investigate and compare the functional hemostatic response in whole blood and plasma during experimental human endotoxemia by the platelet function analyzer, Multiplate and by standard and modified thrombelastography (TEG.Prospective physiologic study of nine healthy male volunteers undergoing endotoxemia by means of a 4-hour infusion of E. coli lipopolysaccharide (LPS, 0.5 ng/kg/hour, with blood sampled at baseline and at 4 h and 6 h. Physiological and standard biochemical data and coagulation tests, TEG (whole blood: TEG, heparinase-TEG, Functional Fibrinogen; plasma: TEG±tissue-type plasminogen activator (tPA and Multiplate (TRAPtest, ADPtest, ASPItest, COLtest were recorded. Mixed models with Tukey post hoc tests and correlations were applied.Endotoxemia induced acute SIRS with increased HR, temperature, WBC, CRP and procalcitonin and decreased blood pressure. It also induced a hemostatic response with platelet consumption and reduced APTT while INR increased (all p<0.05. Platelet aggregation decreased (all tests, p<0.05, whereas TEG whole blood clot firmness increased (G, p = 0.05. Furthermore, during endotoxemia (4 h, whole blood fibrinolysis increased (clot lysis time (CLT, p<0.001 and Functional Fibrinogen clot strength decreased (p = 0.049. After endotoxemia (6 h, whole blood fibrinolysis was reduced (CLT, p<0.05. In contrast to findings in whole blood, the plasma fibrin clot became progressively more resistant towards tPA-induced fibrinolysis at both 4 h and 6 h (p<0.001.Endotoxemia induced a hemostatic response with reduced primary but enhanced secondary hemostasis, enhanced early fibrinolysis and fibrinogen consumption followed by downregulation of fibrinolysis, with a discrepant fibrinolytic response in plasma and whole blood. The finding that blood cells are

  10. Computational Fluid Dynamics Analysis of Cold Plasma Plume Mixing with Blood Using Level Set Method Coupled with Heat Transfer

    Directory of Open Access Journals (Sweden)

    Mehrdad Shahmohammadi Beni

    2017-06-01

    Full Text Available Cold plasmas were proposed for treatment of leukemia. In the present work, conceptual designs of mixing chambers that increased the contact between the two fluids (plasma and blood through addition of obstacles within rectangular-block-shaped chambers were proposed and the dynamic mixing between the plasma and blood were studied using the level set method coupled with heat transfer. Enhancement of mixing between blood and plasma in the presence of obstacles was demonstrated. Continuous tracking of fluid mixing with determination of temperature distributions was enabled by the present model, which would be a useful tool for future development of cold plasma devices for treatment of blood-related diseases such as leukemia.

  11. Hypergravity-induced increase in plasma catecholamine and corticosterone levels in telemetrically collected blood of rats during centrifugation.

    Science.gov (United States)

    Petrak, Juraj; Mravec, Boris; Jurani, Marian; Baranovska, Magda; Tillinger, Andrej; Hapala, Ivan; Frollo, Ivan; Kvetnanský, Richard

    2008-12-01

    Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI), norepinephrine (NE), and corticosterone. However, the collection of blood was performed after a centrifugation finished, and therefore the levels could be affected by the process of deceleration. The aim of this study was to evaluate plasma EPI, NE, and corticosterone levels in blood collected directly during centrifugation after reaching different G (2-6), using newly developed remote-controlled equipment. Animals placed into the centrifuge cabins had inserted polyethylene tubing in the tail artery, which was connected with a preprogrammed device for blood withdrawals. Plasma EPI, NE, and corticosterone levels were measured at different time intervals of hypergravity of 2-6G. Plasma EPI levels showed a huge, hypergravity-level-dependent increase. After the last blood collection was completed during hypergravity, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples, plasma EPI showed significantly lower levels compared to centrifugation intervals. Plasma NE levels were significantly increased after 6G only. The increase in plasma corticosterone was dependent on level of G, however after the centrifuge stopped, corticosterone levels remained elevated. Thus, our data show that hypergravity highly activates the adrenomedullary and hypothalamo-pituitary-adrenocortical systems, whereas the sympathoneural system is activated only at high hypergravity. Immediately after centrifugation is over, EPI levels quickly return to control values. Our technique of blood collection during centrifugation allows assessment of the real hormonal levels at the particular hypergravity value.

  12. 21 CFR 864.9205 - Blood and plasma warming device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood and plasma warming device. 864.9205 Section 864.9205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  13. A simple, rapid and stability indicating validated method for quantification of lamotrigine in human plasma and dry plasma spot using LC-ESI-MS/MS: Application in clinical study.

    Science.gov (United States)

    Namdev, Kuldeep Kumar; Dwivedi, Jaya; Chilkoti, Deepak Chandra; Sharma, Swapnil

    2018-01-01

    Lamotrigine (LTZ) is a phenyltriazine derivative which belongs to anti-epileptic drugs (AEDs) class and prescribed as mono- or adjunctive-therapy in treatment of epilepsy. Therapeutic drug monitoring (TDM) of AEDs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) are suitable alternative to overcome these issues. We developed and validated a new method for quantification of LTZ in human plasma and DPS. The extraction of LTZ from plasma and DPS was performed using liquid-liquid extraction with diethyl ether and an extraction solution composed of diethyl ether- methyl tert-butyl ether- acetone (50:30:20, v/v/v), respectively. Lamotrigine- 13C3, d3 was used as internal standard (ISTD) and the chromatographic separation was achieved on Hypurity Advance C18 column (150×4.6mm, 5μm). Quantitative estimation of LTZ and ISTD was performed on a liquid chromatography tandem mass spectrometer coupled with electrospray ionization interface operated under positive mode of ionization. Calibration curves were linear (r 2 >0.99) over the concentration range of 10-3020ng/mL for both plasma and DPS. Statistical analysis provides insignificant difference between LTZ concentration extracted from plasma and DPS samples. The method is found suitable for application in clinical study and in therapeutic monitoring of LTZ. To the best of our knowledge this is the first report which describing a validated stability indicating assay for quantification of LTZ in dry plasma spot. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Automated processing of whole blood samples into microliter aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  15. Information content of the space-frequency filtering of blood plasma layers laser images in the diagnosis of pathological changes

    Science.gov (United States)

    Ushenko, A. G.; Boychuk, T. M.; Mincer, O. P.; Bodnar, G. B.; Kushnerick, L. Ya.; Savich, V. O.

    2013-12-01

    The bases of method of the space-frequency of the filtering phase allocation of blood plasma pellicle are given here. The model of the optical-anisotropic properties of the albumen chain of blood plasma pellicle with regard to linear and circular double refraction of albumen and globulin crystals is proposed. Comparative researches of the effectiveness of methods of the direct polarized mapping of the azimuth images of blood plasma pcllicle layers and space-frequency polarimetry of the laser radiation transformed by divaricate and holelikc optical-anisotropic chains of blood plasma pellicles were held. On the basis of the complex statistic, correlative and fracta.1 analysis of the filtered frcquencydimensional polarizing azimuth maps of the blood plasma pellicles structure a set of criteria of the change of the double refraction of the albumen chains caused by the prostate cancer was traced and proved.

  16. Ciclosporine A asxay: RIA or HPLC, plasma or total blood

    International Nuclear Information System (INIS)

    Lapalus, P.; Garraffo, R.; Krebs, B.; Lapalus, F.

    1985-01-01

    The two methods now in force for ciclosporine A assay are radioimmunoassay (RIA) and high pressure liquid chromatography (HPLC) in various biological media (plasma, serum, total blood). The advantages and disadvantages of the two methods are presented [fr

  17. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  18. Plasma fractionation for blood products: isolation and purification of coagulating factors, albumin and immunoglobulin

    International Nuclear Information System (INIS)

    Siti Najila Mohd Janib; Shaharuddin Mohd; Wan Hamirul Bahrin Wan Kamal

    2005-01-01

    Approximately 12 million liters of human plasma are fractionated world-wide annually. However, with the market for clotting factors and other haemoderivatives steadily increasing from year to year, the amount processed will also increase correspondingly to keep up with the demand. In Malaysia, part of the need for the blood products are obtained commercially but a major portion of the requirement involves sending the plasma collected by the National Blood Centre to Australia for processing. Following purification and isolation of the blood products, they are sent back to Malaysia for local consumption. As yet there are no plasma fractionation plants in the South East Asia region, it would be advantageous to establish a local fractionation plant as it would be able to cater for local demands of the haemoderivatives and thus reduces the cost of importing these products. Besides, this facility will be able to provide contract fractionation services to the surrounding region. Early work in MINT has started in trying to purify plasma obtained from rats. Purification of the plasma was performed by using Sephadex G-25 column. Short term objective of this project is to develop the technique of extraction, fractionation and purification of blood products such as albumin, globulin and clotting factors (Factor VIII and Factor IX). The long term emphasis will be to scale up the production facility to a pilot plant stage and eventually to a national fractionation and purification plant. (Author)

  19. Oxygen Barrier Coating Deposited by Novel Plasma-enhanced Chemical Vapor Deposition

    DEFF Research Database (Denmark)

    Jiang, Juan; Benter, M.; Taboryski, Rafael Jozef

    2010-01-01

    We report the use of a novel plasma-enhanced chemical vapor deposition chamber with coaxial electrode geometry for the SiOx deposition. This novel plasma setup exploits the diffusion of electrons through the inner most electrode to the interior samples space as the major energy source. This confi......We report the use of a novel plasma-enhanced chemical vapor deposition chamber with coaxial electrode geometry for the SiOx deposition. This novel plasma setup exploits the diffusion of electrons through the inner most electrode to the interior samples space as the major energy source...... effect of single-layer coatings deposited under different reaction conditions was studied. The coating thickness and the carbon content in the coatings were found to be the critical parameters for the barrier property. The novel barrier coating was applied on different polymeric materials...

  20. Deproteinization is Necessary for the Accurate Determination of Ammonia Levels by Glutamate Dehydrogenase Assay in Blood Plasma From Subjects With Liver Injury.

    Science.gov (United States)

    Vodenicarovova, Melita; Skalska, Hana; Holecek, Milan

    2017-11-08

    To determine the effect of presence of high concentrations of nicotinamide adenine dinucleotide (NADH)- and nicotinamide adenine dinucleotide phosphate (NADPH)-consuming enzymes on the accuracy of glutamate dehydrogenase (GLDH) assay for ammonia. We measured ammonia concentrations using GLDH and NADH or NADPH in blood-plasma specimens and specimens deproteinized by sulfosalicylic acid from CCl4-treated or control rats. The nonspecific oxidation of NADH and NADPH was measured in mixtures without GLDH. We observed a gradual decrease (~0.5%) in absorbance in the plasma of controls after the addition of NADH but not after adding NADPH. The decrease in absorbance in plasma of CCl4-treated animals was 13.2% and 5.2% after the addition of NADH and NADPH, respectively. The decrease in absorbance was not detected in deproteinized specimens. The values of ammonia concentration were higher in the plasma specimens compared with the deproteinized ones. Deproteinization is necessary for accurate measurement of ammonia using GLDH assay in the blood plasma of subjects with liver injury. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. The clinical significance of determination of peripheral blood TXA2, PGI2, TNF-α levels in patients with acute pancreatitis

    International Nuclear Information System (INIS)

    Hong Guangqiu; Ye Fei; Lin Hao

    2010-01-01

    Objective: To investigate the clinical significance of changes of peripheral blood TXA 2 , PGI 2 , TNF-α levels on assessment of the severity and prognosis of patients with acute pancreatitis (AP). Methods: Peripheral blood levels of TXA 2 , PGI 2 (plasma with RIA) and TNF-α (serum with ELISA) were detected in 30 patients with severe AP (SAP group), 56 patients with mild AP(MAP group) and 40 controls. Results: The peripheral blood levels of TXA 2 , TNF-α in the SAP group were significantly higher than those in the MAP group (P 2 levels were significantly lower (P 2 , PGI 2 and TNF-α levels were closely related to the severity and prognosis of AP and were important clinical indicators. (authors)

  2. The Synergistic Effect between Electrical and Chemical Factors in Plasma Gene/Molecule-Transfection

    Science.gov (United States)

    Jinno, Masafumi

    2016-09-01

    This study has been done to know what kind of factors in plasma and processes on cells promote plasma gene/molecule transfection. We have discovered a new plasma source using a microcapillary electrode which enables high transfection efficiency and high cell survivability simultaneously. However, the mechanism of the transfection by plasma was not clear. To clarify the transfection mechanisms by micro plasma, we focused on the effects of electrical (current, charge, field, etc.) and chemical (radicals, RONS, etc.) factors generated by the micro plasma and evaluated the contribution weight of three groups of the effects and processes, i.e. electrical, chemical and biochemical ones. At first, the necessity of the electrical factors was estimated by the laser produced plasma (LPP). Mouse L-929 fibroblast cell was cultured on a 96-well plate or 12-well micro slide chamber. Plasmids pCX-EGFP in Tris-EDTA buffer was dropped on the cells and they were exposed to the capillary discharge plasma (CDP) or the LPP. In the case of the CDP, the plasma was generated between the tip of the capillary electrode and the cells so that both electrical and chemical factors were supplied to the cells. In this setup, about 20% of average transfection efficiency was obtained. In the case of the LPP, the plasma was generated apart from the cells so that electrical factors were not supplied to the cells. In this setup, no transfection was observed. These results show that the electrical factors are necessary for the plasma gene transfection. Next, the necessity of the chemical factors was estimated the effect of catalase to remove H2O2 in CDP. The transfection efficiency decreased to 0.4 by scavenging H2O2 with catalase. However, only the solution of H2O2 caused no gene transfection in cells. These results shows that H2O2 is important species to cause gene/molecule transfection but still needs a synergistic effect with electrical or other chemical factors. This work was partly supported by

  3. Blood and plasma viscosity in diabetes: possible contribution to late organ complications?

    NARCIS (Netherlands)

    Schut, N. H.; van Arkel, E. C.; Hardeman, M. R.; Bilo, H. J.; Michels, R. P.; Vreeken, J.

    1992-01-01

    It has been postulated that an increased whole blood and plasma viscosity contribute to diabetic organ complications. Blood viscosity was measured in 30 controls and four groups of insulin-dependent diabetic patients at three shear rates: 70 sec-1, 0.5 sec-1 and 0.05 sec-1. Results were compared

  4. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    Science.gov (United States)

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  5. PumpKin: A tool to find principal pathways in plasma chemical models

    Science.gov (United States)

    Markosyan, A. H.; Luque, A.; Gordillo-Vázquez, F. J.; Ebert, U.

    2014-10-01

    PumpKin is a software package to find all principal pathways, i.e. the dominant reaction sequences, in chemical reaction systems. Although many tools are available to integrate numerically arbitrarily complex chemical reaction systems, few tools exist in order to analyze the results and interpret them in relatively simple terms. In particular, due to the large disparity in the lifetimes of the interacting components, it is often useful to group reactions into pathways that recycle the fastest species. This allows a researcher to focus on the slow chemical dynamics, eliminating the shortest timescales. Based on the algorithm described by Lehmann (2004), PumpKin automates the process of finding such pathways, allowing the user to analyze complex kinetics and to understand the consumption and production of a certain species of interest. We designed PumpKin with an emphasis on plasma chemical systems but it can also be applied to atmospheric modeling and to industrial applications such as plasma medicine and plasma-assisted combustion.

  6. Improving plasma resistance and lowering roughness in an ArF photoresist by adding a chemical reaction inhibitor

    International Nuclear Information System (INIS)

    Jinnai, Butsurin; Uesugi, Takuji; Koyama, Koji; Samukawa, Seiji; Kato, Keisuke; Yasuda, Atsushi; Maeda, Shinichi; Momose, Hikaru

    2010-01-01

    Major challenges associated with 193 nm lithography using an ArF photoresist are low plasma resistance and roughness formation in the ArF photoresist during plasma processes. We have previously found decisive factors affecting the plasma resistance and roughness formation in an ArF photoresist: plasma resistance is determined by UV/VUV radiation, and roughness formation is dominated by chemical reactions. In this study, based on our findings on the interaction between plasma radiation species and ArF photoresist polymers, we proposed an ArF photoresist with a chemical reaction inhibitor, which can trap reactive species from the plasma, and characterized the performances of the resultant ArF photoresist through neutral beam experiments. Hindered amine light stabilizers, i.e. 4-hydroxy-2,2,6,6-tetramethyl-1-piperidinyloxy (HO-TEMPO), were used as the chemical reaction inhibitor. Etching rates of the ArF photoresist films were not dependent on the HO-TEMPO content in the irradiations without chemical reactions or under UV/VUV radiation. However, in the irradiation with chemical reactions, the etching rates of the ArF photoresist films decreased as the HO-TEMPO content increased. In addition, the surface roughness decreased with the increase in the additive amount of chemical reaction inhibitor. According to FTIR analysis, a chemical reaction inhibitor can inhibit the chemical reactions in ArF photoresist films through plasma radicals. These results indicate that a chemical reaction inhibitor is effective against chemical reactions, resulting in improved plasma resistance and less roughness in an ArF photoresist. These results also support our suggested mechanism of plasma resistance and roughness formation in an ArF photoresist.

  7. Clinical transfusion practice update: haemovigilance, complications, patient blood management and national standards.

    Science.gov (United States)

    Engelbrecht, Sunelle; Wood, Erica M; Cole-Sinclair, Merrole F

    2013-09-16

    Blood transfusion is not without risk. Although the risks of HIV and hepatitis transmission have diminished, haemovigilance programs highlight that other significant transfusion hazards remain. Sepsis from bacterial contamination is the most common residual infectious hazard in developed countries, and events due to clerical error are problematic. Unnecessary transfusions should be avoided. New national guidelines on patient blood management (PBM) emphasise holistic approaches, including strategies to reduce transfusion requirements. Perioperative PBM should incorporate preoperative haemoglobin and medication optimisation, intraoperative blood conservation, and consideration of restrictive postoperative transfusion and cell-salvage techniques. When massive transfusion is required, hospitals should implement massive transfusion protocols. These protocols reduce mortality, improve communication and facilitate adequate provision of blood products. They should include multidisciplinary team involvement and guidelines for use of blood components and adjunctive agents. Although fresh frozen plasma to red blood cell and platelet to red blood cell ratios of ≥ 1 : 2 appear to reduce mortality in trauma patients who receive massive transfusion, there is insufficient evidence to recommend specific ratios. Systematic reviews have found no significant benefit of recombinant activated factor VII in critical bleeding, and an increase in thromboembolic events; specialist haematology advice is therefore recommended when considering use of this agent. The National Safety and Quality Health Service Standards address use of blood and blood products, and provide important transfusion principles for adoption by all clinicians. Storage of red cells in additive solution results in changes, known as the "storage lesion", and studies to determine the clinical effect of the age of blood at transfusion are ongoing.

  8. Dynamics of blood plasma by spectropolarimetry and biochemical techniques

    Science.gov (United States)

    Voloshynska, Katerina; Ilashchuka, Tetjana; Prydij, Olexander; Gruia, Maria

    2014-08-01

    The aim of the study was to establish objective parameters of the field of laser and incoherent radiation of different spectral ranges (UV, visible, IR) as a non-invasive optical method of interaction with different samples of biological tissues and fluids of patients to determine the dynamics of metabolic syndrome and choosing the best personal treatment. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues.

  9. Spectropolarimetry of blood plasma in optimal molecular targeted therapy

    Science.gov (United States)

    Voloshynska, Katerina; Ilashchuk, Tetjana; Yermolenko, Sergey

    2015-02-01

    The aim of the study was to establish objective parameters of the field of laser and incoherent radiation of different spectral ranges (UV, visible, IR) as a non-invasive optical method of interaction with different samples of biological tissues and fluids of patients to determine the dynamics of metabolic syndrome and choosing the best personal treatment. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues.

  10. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  11. Chemical analysis of refractories by plasma spectrometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.

    1990-01-01

    X-ray spectrometry has been, since the last two or three decades, the traditional procedure for the chemical analysis of refractories, due to its high degree of accuracy and speed to produce analytical results. An interesting alternative to X-ray fluorescence is provided by the Inductively Coupled Plasma Spectrometry technique, for those laboratories where wet chemistry facilities are already available or process control is not required at high speed, or investiment costs have to be low. This paper presents results obtained by plasma spectroscopy for the analysis of silico - aluminous refractories, showing calibration curves, precion and detection limits. Considerations and comparisons with X-ray fluorescence are also made. (author) [pt

  12. Clinical signs and hematologic, cytokine, and plasma nitric oxide alterations in response to Strongylus vulgaris infection in helminth-naïve ponies.

    Science.gov (United States)

    Hubert, Jeremy D; Seahorn, Thomas L; Klei, Thomas R; Hosgood, Giselle; Horohov, David W; Moore, Rustin M

    2004-07-01

    The objective of this study was to determine the effect of infection with Strongylus vulgaris on serum cytokines and plasma nitric oxide (NO) concentrations in helminth-naive ponies. Group 1 (n = 21) was given 500 S. vulgaris L3 larvae and group 2 (n = 7) received a saline control. Ponies were monitored daily for clinical signs, and blood was collected for complete blood cell counts and serum cytokines (TNF, IL-1, IL-6) quantification. Group 1 ponies were depressed, anorexic, and febrile for variable periods of time. Plasma NO was increased on day 21 in group 1 and on days 9 and 21 in group 2. Significant increases in total white blood cell counts, fibrinogen, and plasma protein concentrations in group 1 were found. Significant decreases in red blood cell counts and packed cell volume were also noted in group 1. There were no differences in serum cytokines across time in either group of ponies. Despite the lack of proinflammatory cytokine induction with the apparent inflammatory response to S. vulgaris there is evidence of a potential role of NO.

  13. Optimum time of blood sampling for determination of glomerular filtration rate by single-injection [51Cr]EDTA plasma clearance

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    We have investigated the influence on reproducibility of total [ 51 Cr]EDTA plasma clearance (E) of various times and numbers of blood samples in patients with normal (13 patients) and low (14 patients) renal function. The study aims at fixing a clinically useful procedure suitable for all levels of renal function. Six different types of E were evaluated with time periods for blood sampling between 3 and 5 h after tracer injection, and the variation from counting radioactivity, s 1 , was determined as part of the total variation, s 2 . Optimum mean time, t(E), for blood sampling was calculated as a function of E, as the mean time giving the least change in E for a given change in the 'final slope' of the plasma curve. For patients with normal E, s 1 did not contribute significantly to s 2 , and t(E) was about 2h. For patients with low renal function s 1 contributed significantly to s 2 , and t(E) increased steeply with decreasing E. The relative error in s 1 from fixed Etypes was calculated for all levels of renal function. The results indicate that blood sampling individualized according to predicted E values is not necessary. A sufficient precision of E can be achieved for all function levels from three blood samples drawn at 180, 240, and 300 min after injection. (Auth.)

  14. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube

    Science.gov (United States)

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-01-01

    Introduction Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Materials and methods Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Results Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Conclusions Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment. PMID:28900369

  15. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

    Science.gov (United States)

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-10-15

    Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment.

  16. Developing a Highly Active Blood Anticoagulant—a Heparin Complex with Glutamic Acid—by Simulating Chemical Equilibria Based on pH-Metric Data

    Science.gov (United States)

    Nikolaeva, L. S.; Semenov, A. N.

    2018-02-01

    The anticoagulant activity of high-molecular-weight heparin is increased by developing a new highly active heparin complex with glutamate using the thermodynamic model of chemical equilibria based on pH-metric data. The anticoagulant activity of the developed complexes is estimated in the pH range of blood plasma according to the drop in the calculated equilibrium Ca2+ concentration associated with the formation of mixed ligand complexes of Ca2+ ions, heparin (Na4hep), and glutamate (H2Glu). A thermodynamic model is calculated by mathematically modelling chemical equilibria in the CaCl2-Na4hep-H2Glu-H2O-NaCl system in the pH range of 2.30 ≤ pH ≤ 10.50 in diluted saline that acts as a background electrolyte (0.154 M NaCl) at 37°C and initial concentrations of the main components of ν × 10-3 M, where n ≤ 4. The thermodynamic model is used to determine the main complex of the monomeric unit of heparin with glutamate (HhepGlu5-) and the most stable mixed ligand complex of Ca2+ with heparin and glutamate (Ca2hepGlu2-) in the pH range of blood plasma (6.80 ≤ pH ≤ 7.40). It is concluded that the Ca2hepGlu2- complex reduces the Ca2+ concentration 107 times more than the Ca2+ complex with pure heparin. The anticoagulant effect of the developed HhepGlu5- complex is confirmed in vitro and in vivo via coagulation tests on the blood plasma of laboratory rats. Additional antithrombotic properties of the developed complex are identified. The new highly active anticoagulant, HhepGlu5- complex with additional antithrombotic properties, is patented.

  17. studies on blood and plasma biochemical characteristics of the ...

    African Journals Online (AJOL)

    User

    A study to determine the blood parameters and plasma biochemical values of ... highest in animals at the 4th month state (9.75g/dl) and lowest at the 12th ... study is indicative of satisfactory physiological, nutritional and pathological ... domestication and integration into the micro-livestock farming system is ..... Principles and.

  18. Intestinal Microbiota-Derived Metabolomic Blood Plasma Markers for Prior Radiation Injury

    International Nuclear Information System (INIS)

    Ó Broin, Pilib; Vaitheesvaran, Bhavapriya; Saha, Subhrajit; Hartil, Kirsten; Chen, Emily I.; Goldman, Devorah; Fleming, William Harv; Kurland, Irwin J.; Guha, Chandan; Golden, Aaron

    2015-01-01

    Purpose: Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Methods and Materials: Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative, untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. Results: We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Conclusions: Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma

  19. Intestinal Microbiota-Derived Metabolomic Blood Plasma Markers for Prior Radiation Injury

    Energy Technology Data Exchange (ETDEWEB)

    Ó Broin, Pilib [Department of Genetics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Department of Mathematical Sciences, Yeshiva University, New York, New York (United States); Vaitheesvaran, Bhavapriya [Department of Medicine, Diabetes Center, Stable Isotope and Metabolomics Core Facility, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Saha, Subhrajit [Department of Radiation Oncology, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Hartil, Kirsten [Department of Medicine, Diabetes Center, Stable Isotope and Metabolomics Core Facility, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Chen, Emily I. [Department of Pharmacology, Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, New York (United States); Goldman, Devorah; Fleming, William Harv [Department of Medicine, Oregon Health and Science University, Portland, Oregon (United States); Kurland, Irwin J. [Department of Medicine, Diabetes Center, Stable Isotope and Metabolomics Core Facility, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Guha, Chandan, E-mail: cguha@montefiore.org [Department of Radiation Oncology, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Golden, Aaron, E-mail: aaron.golden@einstein.yu.edu [Department of Genetics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York (United States); Department of Mathematical Sciences, Yeshiva University, New York, New York (United States)

    2015-02-01

    Purpose: Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Methods and Materials: Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative, untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. Results: We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Conclusions: Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma.

  20. Intestinal microbiota-derived metabolomic blood plasma markers for prior radiation injury.

    Science.gov (United States)

    Ó Broin, Pilib; Vaitheesvaran, Bhavapriya; Saha, Subhrajit; Hartil, Kirsten; Chen, Emily I; Goldman, Devorah; Fleming, William Harv; Kurland, Irwin J; Guha, Chandan; Golden, Aaron

    2015-02-01

    Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative, untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. A solid-state nuclear magnetic resonance study of post-plasma reactions in organosilicone microwave plasma-enhanced chemical vapor deposition (PECVD) coatings.

    Science.gov (United States)

    Hall, Colin J; Ponnusamy, Thirunavukkarasu; Murphy, Peter J; Lindberg, Mats; Antzutkin, Oleg N; Griesser, Hans J

    2014-06-11

    Plasma-polymerized organosilicone coatings can be used to impart abrasion resistance and barrier properties to plastic substrates such as polycarbonate. Coating rates suitable for industrial-scale deposition, up to 100 nm/s, can be achieved through the use of microwave plasma-enhanced chemical vapor deposition (PECVD), with optimal process vapors such as tetramethyldisiloxane (TMDSO) and oxygen. However, it has been found that under certain deposition conditions, such coatings are subject to post-plasma changes; crazing or cracking can occur anytime from days to months after deposition. To understand the cause of the crazing and its dependence on processing plasma parameters, the effects of post-plasma reactions on the chemical bonding structure of coatings deposited with varying TMDSO-to-O2 ratios was studied with (29)Si and (13)C solid-state magic angle spinning nuclear magnetic resonance (MAS NMR) using both single-pulse and cross-polarization techniques. The coatings showed complex chemical compositions significantly altered from the parent monomer. (29)Si MAS NMR spectra revealed four main groups of resonance lines, which correspond to four siloxane moieties (i.e., mono (M), di (D), tri (T), and quaternary (Q)) and how they are bound to oxygen. Quantitative measurements showed that the ratio of TMDSO to oxygen could shift the chemical structure of the coating from 39% to 55% in Q-type bonds and from 28% to 16% for D-type bonds. Post-plasma reactions were found to produce changes in relative intensities of (29)Si resonance lines. The NMR data were complemented by Fourier transform infrared (FTIR) spectroscopy. Together, these techniques have shown that the bonding environment of Si is drastically altered by varying the TMDSO-to-O2 ratio during PECVD, and that post-plasma reactions increase the cross-link density of the silicon-oxygen network. It appears that Si-H and Si-OH chemical groups are the most susceptible to post-plasma reactions. Coatings produced at a

  2. Membrane-based, sedimentation-assisted plasma separator for point-of-care applications.

    Science.gov (United States)

    Liu, Changchun; Mauk, Michael; Gross, Robert; Bushman, Frederic D; Edelstein, Paul H; Collman, Ronald G; Bau, Haim H

    2013-11-05

    Often, high-sensitivity, point-of-care (POC) clinical tests, such as HIV viral load, require large volumes of plasma. Although centrifuges are ubiquitously used in clinical laboratories to separate plasma from whole blood, centrifugation is generally inappropriate for on-site testing. Suitable alternatives are not readily available to separate the relatively large volumes of plasma from milliliters of blood that may be needed to meet stringent limit-of-detection specifications for low-abundance target molecules. We report on a simple-to-use, low-cost, pump-free, membrane-based, sedimentation-assisted plasma separator capable of separating a relatively large volume of plasma from undiluted whole blood within minutes. This plasma separator consists of an asymmetric, porous, polysulfone membrane housed in a disposable chamber. The separation process takes advantage of both gravitational sedimentation of blood cells and size exclusion-based filtration. The plasma separator demonstrated a "blood in-plasma out" capability, consistently extracting 275 ± 33.5 μL of plasma from 1.8 mL of undiluted whole blood within less than 7 min. The device was used to separate plasma laden with HIV viruses from HIV virus-spiked whole blood with recovery efficiencies of 95.5% ± 3.5%, 88.0% ± 9.5%, and 81.5% ± 12.1% for viral loads of 35,000, 3500, and 350 copies/mL, respectively. The separation process is self-terminating to prevent excessive hemolysis. The HIV-laden plasma was then injected into our custom-made microfluidic chip for nucleic acid testing and was successfully subjected to reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP), demonstrating that the plasma is sufficiently pure to support high-efficiency nucleic acid amplification.

  3. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  4. Plasma surface reflectance spectroscopy for non-invasive and continuous monitoring of extracellular component of blood

    Science.gov (United States)

    Sakota, Daisuke; Takatani, Setsuo

    2012-04-01

    To achieve the quantitative optical non-invasive diagnosis of blood during extracorporeal circulation therapies, the instrumental technique to extract extracellular spectra from whole blood was developed. In the circuit, the continuous blood flow was generated by a centrifugal blood pump. The oxygen saturation was maintained 100% by an oxygenator. The developed glass optical flow cell was attached to the outlet tubing of the oxygenator. The halogen lamp including the light from 400 to 900 nm wavelength was used for the light source. The light was guided into an optical fiber. The light emitted by the fiber was collimated and emitted to the flow cell flat surface at the incident angle of 45 degrees. The light just reflected on the boundary between inner surface of the flow cell and plasma at 45 degrees was detected by the detection fiber. The detected light was analyzed by a spectral photometer. The obtained spectrum from 400 to 600nm wavelength was not changed with respect to the hematocrit. In contrast, the signal in the spectral range was changed when the plasma free hemoglobin increased. By using two spectral range, 505+/-5 nm and 542.5+/-2.5 nm, the differential spectrum was correlated with the free hemoglobin at R2=0.99. On the other hand, as for the hematocrit, the differential spectrum was not correlated at R2=0.01. Finally, the plasma free hemoglobin was quantified with the accuracy of 22+/-19mg/dL. The result shows that the developed plasma surface reflectance spectroscopy (PSRS) can extract the plasma spectrum from flowing whole blood.

  5. High plasma corticosterone levels persist during frequent automatic blood sampling in rats

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Adem, Bashir; Royo, Felix

    2005-01-01

    Corticosterone levels in blood may be used as a marker of stress in rodents, provided that the blood sampling procedure itself is non-stressful. Automated blood sampling equipment (Accusampler) allows blood sampling without any interference with the animal and might be useful as a tool for an on......-line measurement of stress markers in blood. However, the impact of the blood sampling itself on the corticosterone levels in blood is unknown. The present study was designed to evaluate whether the frequency of blood sampling influences the plasma corticosterone levels in male and female rats. During anaesthesia...... the importance of considering the frequency of blood withdrawal during automated blood sampling. This parameter may have an impact on the experimental results when using blood corticosterone levels as a stress marker, but also during any in vivo study where blood is collected, since high corticosterone levels...

  6. Fast blood plasma separation device for point-of-care applications

    Czech Academy of Sciences Publication Activity Database

    Ďurč, P.; Foret, František; Kubáň, Petr

    2018-01-01

    Roč. 183, JUN (2018), s. 55-60 ISSN 0039-9140 Institutional support: RVO:68081715 Keywords : blood plasma separation * capillary electrophoresis * point of care analysis * methanol * metabolites Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.162, year: 2016

  7. HEMOFILTRATION AND COUPLED PLASMA FILTRATION ADSORPTION IMPACT ON TACROLIMUS BLOOD CONCENTRATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    A.V. Vatazin

    2014-01-01

    Full Text Available Aim. To study the effect of hemofi ltration and coupled plasma fi ltration adsorption on tacrolimus blood concentration in renal transplant recipients.Methods and results. The study included 8 renal transplant recipients. In these patients immediately after the operation was performed the coupled plasma fi ltration adsorption with hemofiltration using a cartridge Mediasorb to reduce the severity of reperfusion injury. We have found that during this extracorporeal blood correction procedure there was statistically not signifi cant decrease of tacrolimus blood concentration. However, concentration of tacrolimus remained in the therapeutic range even after the procedure and it was not signifi cantly different from the control point С0.Conclusion. Coupled plasma fi ltration adsorption is safe in renal transplant recipients and has no signifi cant impact on tacrolimus blood concentration. However, the downward trend in the concentration of tacrolimus in the course of these procedures, especially in continuous or semicontinuous mode, as well as in patients with low hematocrit and hypoalbuminemia, requires individual monitoring.

  8. Fundamental aspects of plasma chemical physics kinetics

    CERN Document Server

    Capitelli, Mario; Colonna, Gianpiero; Esposito, Fabrizio; Gorse, Claudine; Hassouni, Khaled; Laricchiuta, Annarita; Longo, Savino

    2016-01-01

    Describing non-equilibrium "cold" plasmas through a chemical physics approach, this book uses the state-to-state plasma kinetics, which considers each internal state as a new species with its own cross sections. Extended atomic and molecular master equations are coupled with Boltzmann and Monte Carlo methods to solve the electron energy distribution function. Selected examples in different applied fields, such as microelectronics, fusion, and aerospace, are presented and discussed including the self-consistent kinetics in RF parallel plate reactors, the optimization of negative ion sources and the expansion of high enthalpy flows through nozzles of different geometries. The book will cover the main aspects of the state-to-state kinetic approach for the description of nonequilibrium cold plasmas, illustrating the more recent achievements in the development of kinetic models including the self-consistent coupling of master equations and Boltzmann equation for electron dynamics. To give a complete portrayal, the...

  9. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  10. Simplified sample preparation in the simultaneous measurement of whole blood antimony, bismuth, manganese, and zinc by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Haglock-Adler, Carrie J; Strathmann, Frederick G

    2015-02-01

    We developed and validated a simplified sample preparation for the analysis of antimony (Sb), bismuth (Bi), manganese (Mn), and zinc (Zn) in whole blood. This simplification included a reduction in sample volume, removal of a lengthy acidic digestion, and optimization of the internal standard. Measurement of Sb, Bi, Mn and Zn in whole blood was conducted using inductively coupled-plasma mass spectrometry. Method performance characteristics, including intra- and inter-assay imprecision, accuracy, linearity, AMR, sensitivity, carryover, sample stability and assay stability were determined in accordance with clinical laboratory standards. In addition, analytical and clinical recoveries were assessed to investigate comparability between goat blood matrix and pooled patient blood. Established assay performance characteristics included inter- and intra-assay imprecision samples, proficiency testing samples, and comparison to an outside reference laboratory. This method overcomes the laborious acidic heat digestion previously used and replaces it with a simplified sample preparation involving an alkaline dilution. The method requires minimal sample preparation with the dilution of alkaline diluent and is validated to quantify Sb and Bi from 1 to 25 μg/L, Mn from 1 to 80 μg/L, and Zn from 50 to 1500 μg/dL in whole blood. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Stability of magnetite nanoparticles with different coatings in a simulated blood plasma

    Energy Technology Data Exchange (ETDEWEB)

    Favela-Camacho, Sarai E.; Pérez-Robles, J. Francisco [Center for Research and Advanced Studies of National Polytechnic Institute, CINVESTAV-Querétaro Unit (Mexico); García-Casillas, Perla E. [Autonomous University of Juarez, Department of Materials Science, Institute of Engineering and Technology (Mexico); Godinez-Garcia, Andrés, E-mail: andgodinez@xanum.uam.mx [Universidad Autónoma Metropolitana, Departamento de Ingeniería de Procesos e Hidráulica (Mexico)

    2016-07-15

    Magnetite nanoparticles (MNPs) have demonstrated to be a potential platform for simultaneous anticancer drug delivery and magnetic resonance imaging (MRI). However, magnetite is unstable at the blood plasma conditions. Therefore, to study their stability in a broad range of particle size, the MNPs were synthesized using two methods, the fast injection co-precipitation method (FIC) and the reflux co-precipitation method (RC). The MNPs obtained by the RC and the FIC methods have an average size of agglomerates of 200 and 45 nm respectively. They were dispersed using sodium citrate as surfactant and were coated with silica and chitosan. A total of four kind of coated MNPs were synthesized: magnetite/sodium citrate, magnetite/silica, magnetite/sodium citrate/silica and magnetite/sodium citrate/silica/chitosan. Different samples of the coated MNPs were immersed in a simulated blood plasma solution (Phosphate-Buffered Saline, PBS, Gibco{sup ®}), for periods of 24, 48 and 72 h. Inductively coupled plasma (ICP) technique was used to analyze the composition of the simulated plasma after those periods of time. The obtained results suggest that the uncoated samples showed an appreciable weight loss, and the iron composition in the simulated plasma increased. This last means that the used coatings avoid iron dissolution from the MNPs.Graphical abstract.

  12. Coupled plasma filtration adsorption: rationale, technical development and early clinical experience.

    Science.gov (United States)

    Ronco, Claudio; Brendolan, Alessandra; d'Intini, Vincenzo; Ricci, Zaccaria; Wratten, Mary Lou; Bellomo, Rinaldo

    2003-01-01

    The adjuvant treatment of sepsis remains a major therapeutic challenge. Blood purification is theoretically appealing if the humoral theory of sepsis is accepted as the basis for intervention. In this setting, blood purification would provide a broad-based restoration of humoral homeostasis thereby avoiding both excessive inflammation and counterinflammation. Several techniques of blood purification have been tried or are under active investigation. One of these is the so-called coupled plasma filtration adsorption (CPFA). CPFA is a novel extracorporeal blood purification therapy aimed at nonselectively reducing the circulating levels and activities of both pro- and anti-inflammatory mediators during sepsis and multiorgan failure. In vitro studies have shown CPFA to be effective in binding a broad range of such mediators proving its technical efficacy. Subsequent animal models have shown a beneficial effect on survival in endotoxemia. These studies have provided the necessary technical developments and biologic rationale for initial human studies. Two phase I/IIa clinical studies have now been performed. Both studies have shown that CPFA improves blood pressure and restores immune function in patients with severe sepsis and multiorgan dysfunction. In this article, we will discuss some of the basic principles involved in sorbent technology, and how these may contribute to treatment efficacy, review animal experiments with CPFA and finally discuss the results of recent human studies and their implications. Copyright 2003 S. Karger AG, Basel

  13. Combined impact of lead, cadmium, polychlorinated biphenyls and non-chemical risk factors on blood pressure in NHANES

    International Nuclear Information System (INIS)

    Peters, Junenette L.; Patricia Fabian, M.; Levy, Jonathan I.

    2014-01-01

    High blood pressure is associated with exposure to multiple chemical and non-chemical risk factors, but epidemiological analyses to date have not assessed the combined effects of both chemical and non-chemical stressors on human populations in the context of cumulative risk assessment. We developed a novel modeling approach to evaluate the combined impact of lead, cadmium, polychlorinated biphenyls (PCBs), and multiple non-chemical risk factors on four blood pressure measures using data for adults aged ≥20 years from the National Health and Nutrition Examination Survey (1999–2008). We developed predictive models for chemical and other stressors. Structural equation models were applied to account for complex associations among predictors of stressors as well as blood pressure. Models showed that blood lead, serum PCBs, and established non-chemical stressors were significantly associated with blood pressure. Lead was the chemical stressor most predictive of diastolic blood pressure and mean arterial pressure, while PCBs had a greater influence on systolic blood pressure and pulse pressure, and blood cadmium was not a significant predictor of blood pressure. The simultaneously fit exposure models explained 34%, 43% and 52% of the variance for lead, cadmium and PCBs, respectively. The structural equation models were developed using predictors available from public data streams (e.g., U.S. Census), which would allow the models to be applied to any U.S. population exposed to these multiple stressors in order to identify high risk subpopulations, direct intervention strategies, and inform public policy. - Highlights: • We evaluated joint impact of chemical and non-chemical stressors on blood pressure. • We built predictive models for lead, cadmium and polychlorinated biphenyls (PCBs). • Our approach allows joint evaluation of predictors from population-specific data. • Lead, PCBs and established non-chemical stressors were related to blood pressure.

  14. Combined impact of lead, cadmium, polychlorinated biphenyls and non-chemical risk factors on blood pressure in NHANES

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Junenette L., E-mail: petersj@bu.edu; Patricia Fabian, M., E-mail: pfabian@bu.edu; Levy, Jonathan I., E-mail: jonlevy@bu.edu

    2014-07-15

    High blood pressure is associated with exposure to multiple chemical and non-chemical risk factors, but epidemiological analyses to date have not assessed the combined effects of both chemical and non-chemical stressors on human populations in the context of cumulative risk assessment. We developed a novel modeling approach to evaluate the combined impact of lead, cadmium, polychlorinated biphenyls (PCBs), and multiple non-chemical risk factors on four blood pressure measures using data for adults aged ≥20 years from the National Health and Nutrition Examination Survey (1999–2008). We developed predictive models for chemical and other stressors. Structural equation models were applied to account for complex associations among predictors of stressors as well as blood pressure. Models showed that blood lead, serum PCBs, and established non-chemical stressors were significantly associated with blood pressure. Lead was the chemical stressor most predictive of diastolic blood pressure and mean arterial pressure, while PCBs had a greater influence on systolic blood pressure and pulse pressure, and blood cadmium was not a significant predictor of blood pressure. The simultaneously fit exposure models explained 34%, 43% and 52% of the variance for lead, cadmium and PCBs, respectively. The structural equation models were developed using predictors available from public data streams (e.g., U.S. Census), which would allow the models to be applied to any U.S. population exposed to these multiple stressors in order to identify high risk subpopulations, direct intervention strategies, and inform public policy. - Highlights: • We evaluated joint impact of chemical and non-chemical stressors on blood pressure. • We built predictive models for lead, cadmium and polychlorinated biphenyls (PCBs). • Our approach allows joint evaluation of predictors from population-specific data. • Lead, PCBs and established non-chemical stressors were related to blood pressure.

  15. Liquid assisted plasma enhanced chemical vapour deposition with a non-thermal plasma jet at atmospheric pressure

    Czech Academy of Sciences Publication Activity Database

    Schäfer, J.; Fricke, K.; Mika, Filip; Pokorná, Zuzana; Zajíčková, L.; Foest, R.

    2017-01-01

    Roč. 630, MAY 30 (2017), s. 71-78 ISSN 0040-6090 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : plasma jet * liquid assisted plasma enhanced chemical * vapour deposition * silicon oxide Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Coating and films Impact factor: 1.879, year: 2016

  16. Justifying the clinical use of fresh frozen plasma-an audit

    International Nuclear Information System (INIS)

    Sharif, M.M.; Maqbool, S.; Butt, T.K.; Iqbal, S.; Mumtaz, A.

    2007-01-01

    To determine the appropriateness of fresh frozen plasma (FFP), uses in various haematological and clinical disorders, with reference to the British Committee for Standards in Haematology (BCSH) guidelines through an audit. The data was collected from June 2001 to June 2004 from the request forms ordered by the clinicians for the transfusion of FFP at the Department of Haematology and Transfusion Medicine, Shalamar Hospital, Lahore. A total of 2075 healthy blood donors donated their whole blood for the preparation of fresh frozen plasma (FFP). All blood donors were screened for anti HCV, HBsAg, VDRL and HIV. Those 2075 FFP units were prepared on high-speed centrifuge and were rapidly stored at -30 degree C freezer. A total of 587 patients were transfused 2075 units of FFP for various clinical disorders. The percentage of FFP units, transfused appropriately and inappropriately, as defined by BCSH guidelines, was estimated. Out of 2075 FFP units, 335 (24.41%) FFP units were transfused to patients suffering from bleeding due to disseminated intravascular coagulation (DIC), 306 (22.30%) units used for massive transfusion and surgical bleeding, 236 (17.20%) units for bleeding due to chronic liver disease, 202 (14.72%) units used to control bleeding due to coagulation factor deficiencies, 84(6.12%) units for thrombotic thrombocytopenic purpura (TTP), 75(5.46%) units prior to liver biopsy to correct prolonged prothrombin time (PT), 72(5.24%) units for haemorrhage due to haemolytic disease of newborn (HDN) and 62(4.51%) units to control bleeding due to warfarin overdosage, 425(60.45%) units used for nutritional support and hypovolaemia replacement, 131(18.63%) units for the reversal of prolonged INR in the absence of bleeding due to warfarin, 92 (13.08%) units used in ICU to correct prolonged PT without bleeding due to Vitamin K deficiency and 55(7.82%) units for chronic liver disease (CLD) to correct prolonged PT and APTT in the absence of bleeding. In summary, 1372 (66

  17. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  18. Effects of spontaneously hypertensive rat plasma on blood pressure and tail artery calcium uptake in normotensive rats

    International Nuclear Information System (INIS)

    Lewanczuk, R.Z.; Wang, J.; Zhang, Z.R.; Pang, P.K.

    1989-01-01

    Previous studies have described the presence of humoral hypertensive factors in spontaneously hypertensive rats (SHR). Other studies have described factors that increase calcium uptake in vascular tissue. In this study, we attempted to confirm, and thereby correlate, the presence of both types of factors in SHR plasma. Intravenous infusion or bolus administration of dialyzed SHR plasma consistently induced an increase in blood pressure in normotensive rats. This hypertensive response was somewhat delayed, with peak blood pressures occurring 45 minutes after bolus administration and 90 minutes after infusion of SHR plasma. Spontaneously hypertensive rat plasma also increased 45 Ca uptake in isolated normotensive rat tail arteries in a dose-dependent manner, with a time course similar to that for the hypertensive response to bolus administration. These findings suggest, therefore, that a substance exists in SHR plasma that can increase intracellular calcium in vascular tissues and thereby increase blood pressure

  19. Simultaneous determination of CRP and D-dimer in human blood plasma samples with White Light Reflectance Spectroscopy.

    Science.gov (United States)

    Koukouvinos, Georgios; Petrou, Panagiota; Misiakos, Konstantinos; Drygiannakis, Dimitris; Raptis, Ioannis; Stefanitsis, Gerasimos; Martini, Spyridoula; Nikita, Dimitra; Goustouridis, Dimitrios; Moser, Isabella; Jobst, Gerhard; Kakabakos, Sotirios

    2016-10-15

    A dual-analyte assay for the simultaneous determination of C-reactive protein (CRP) and D-dimer in human blood plasma based on a white light interference spectroscopy sensing platform is presented. Measurement is accomplished in real-time by scanning the sensing surface, on which distinct antibody areas have been created, with a reflection probe used both for illumination of the surface and collection of the reflected interference spectrum. The composition of the transducer, the sensing surface chemical activation and biofunctionalization procedures were optimized with respect to signal magnitude and repeatability. The assay format involved direct detection of CRP whereas for D-dimer a two-site immunoassay employing a biotinylated reporter antibody and reaction with streptavidin was selected. The assays were sensitive with detection limits of 25ng/mL for both analytes, precise with intra- and inter-assay CV values ranging from 3.6% to 7.7%, and from 4.8% to 9.5%, respectively, for both assays, and accurate with recovery values ranging from 88.5% to 108% for both analytes. Moreover, the values determined for the two analytes in 35 human plasma samples were in excellent agreement with those received for the same samples by standard diagnostic laboratory instrumentation employing commercial kits. The excellent agreement of the results supported the validity of the proposed system for clinical application for the detection of multiple analytes since it was demonstrated that up to seven antibody areas can be created on the sensing surface and successfully interrogated with the developed optical set-up. Copyright © 2015. Published by Elsevier B.V.

  20. Blood plasma proteins and protein fractions in roe deer Capreolus capreolus L.

    Directory of Open Access Journals (Sweden)

    Dorota CYGAN-SZCZEGIELNIAK

    2015-09-01

    Full Text Available The aim of the research was to investigate some selected biochemical blood parameters in roe deer (Capreolus capreolus L.. The experiment covered 15 from 2 to 3-year-old bucks from Kuyavian-Pomeranian Voivodeship. The animals were shot by individual hunters on the shooting grounds during the hunting season of 2008/2009 (in the accordance with the Journal of Laws No 48. The material for the research was blood plasma obtained after centrifuging full, nonhemolyzed blood. The blood was collected from the zygomatic vein directly to the test tubes with EDTA and transported in cooling conditions to the laboratory. After transporting the samples of blood to a certified analytical laboratory, the following elements of the obtained blood plasma were examined: ceruloplasmin . using turbidimetric method; transferrin . using immunoturbimetric method; troponin- using a third generation assay on an Elecsys; total protein, albumin, globulin . using spectrophotometric method and total iron . using colorimetric method. The results were statistically analyzed, i.e. the correlation between the parameters was measured by means of Pearsonfs correlation coefficient. The analysis of the results revealed a number of statistically significant relations between the parameters under the investigation, especially among the compounds directly responsible for metabolism of iron and copper. A statistically important positive correlation was observed between ceruloplasmin and ferritin (r = 0.563; P.0.05 and a negative one between transferrin and troponin (r = -0.609; P.0.05. Moreover, the content of transferrin . an iron-binding protein . was 0.17 g/l, while the concentration of iron was 58 ƒĘmol/l. The content of ceruloplasmin . a protein responsible for metabolism of copper . was very low (0.036 g/l. The level of proteins in the blood plasma of the animals under the research was approximately 72 g/l, with the share of albumins about 46%. The albumin-globulin ratio was 0.86.

  1. Standardized 15N tracer methods for the evaluation of the plasma protein turnover in clinical practice. 1

    International Nuclear Information System (INIS)

    Bornhak, H.

    1984-01-01

    Methods for quantitative isolation of plasma proteins or groups of proteins (total plasma or serum proteins, fibrin, total globulines, α, β, γ-globolines, albumin) are described based on combination of chromatography with precipitation and extraction techniques. These methods are adapted to the special requirements of 15 N analysis. They can be performed in clinic-chemical standard laboratories without special apparatuses or devices. The described procedures are the biochemico-analytical basis for the quantitative evaluation of tracer kinetics data by means of mathematic modelling. (author)

  2. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    Science.gov (United States)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Wu, Chun-Han; Lin, Yu-Cheng

    2014-09-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood.

  3. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    International Nuclear Information System (INIS)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Lin, Yu-Cheng; Wu, Chun-Han

    2014-01-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood. (paper)

  4. Silenced uses and moral ideals in the exchange of Danish blood and plasma

    DEFF Research Database (Denmark)

    Sheikh, Zainab Afshan; Deleuran, Ida; Hoeyer, Klaus

    2016-01-01

    This article explores the interplay between cultural discourses, moral reasoning and silenced uses in the international exchange of Danish blood plasma. Campaigns, policymakers, health professionals working in the blood banks – and even donors – consistently refer to ideals portraying blood....... However, we find that available cultural discourses poorly capture the moral reasoning among many donors. In fact, when informed about the existing forms of tender, plasma trade sounds like a good idea to most of them. Furthermore, they are not particularly interested in information. We argue...... that the silencing of trade is infusing the system with an unnecessary vulnerability that could easily be avoided with a different communication strategy towards donors. To arrive at new and better strategies, however, one must move beyond the immediate words and reactions of donors contemplating trade and seek...

  5. Onlay bone augmentation on mouse calvarial bone using a hydroxyapatite/collagen composite material with total blood or platelet-rich plasma.

    Science.gov (United States)

    Ohba, Seigo; Sumita, Yoshinori; Umebayashi, Mayumi; Yoshimura, Hitoshi; Yoshida, Hisato; Matsuda, Shinpei; Kimura, Hideki; Asahina, Izumi; Sano, Kazuo

    2016-01-01

    The aim of this study was to assess newly formed onlay bone on mouse calvarial bone using a new artificial bone material, a hydroxyapatite/collagen composite, with total blood or platelet-rich plasma. The hydroxyapatite/collagen composite material with normal saline, total blood or platelet-rich plasma was transplanted on mouse calvarial bone. The mice were sacrificed and the specimens were harvested four weeks after surgery. The newly formed bone area was measured on hematoxylin and eosin stained specimens using Image J software. The hydroxyapatite/collagen composite materials with total blood or platelet-rich plasma induced a significantly greater amount of newly formed bone than that with normal saline. Moreover, bone marrow was observed four weeks after surgery in the transplanted materials with total blood or platelet-rich plasma but not with normal saline. However, there were no significant differences in the amount of newly formed bone between materials used with total blood versus platelet-rich plasma. The hydroxyapatite/collagen composite material was valid for onlay bone augmentation and this material should be soaked in total blood or platelet-rich plasma prior to transplantation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. ABO blood groups and malaria related clinical outcome.

    Science.gov (United States)

    Deepa; Alwar, Vanamala A; Rameshkumar, Karuna; Ross, Cecil

    2011-03-01

    The study was undertaken to correlate the blood groups and clinical presentations in malaria patients and to understand the differential host susceptibility in malaria. From October 2007 to September 2008, malaria positive patients' samples were evaluated in this study. Hemoglobin, total leukocyte count, and platelet count of each patient were done on an automated cell counter. After determining the blood groups, malarial species and the severity of clinical course were correlated. A total of 100 patients were included in the study, of which 63 cases were positive for Plasmodium falciparum and 37 cases were positive for P. vivax infection and 11 patients had mixed infection. The results of the blood groups showed 22 - 'A' group, 42 - 'B' group, 35 - 'O' group and 1 was 'AB' group. When the clinical courses between different groups were compared using the following parameters for severe infection--a parasitic load of >10/1000 RBCs, severe anemia with hemoglobin 101°F and other organ involvement, it was observed that 'O' group had an advantage over other the groups. The difference in rosetting ability between red blood cells of different 'ABO' blood groups with a diminished rosetting potential in blood group 'O' red blood cells was due to the differential host susceptibility. 'O' group had an advantage over the other three blood groups. Based on literature and the results of this study, the diminished rosetting potential in blood group 'O' red blood cells is suggested as the basis for the differential host susceptibility.

  7. Clinical, blood gas and biochemical profile of diarrheic dairy calves fed starter concentrate containing citrus pulp as a replacement for corn

    Directory of Open Access Journals (Sweden)

    Marcelo Cezar Soares

    Full Text Available ABSTRACT: The objective of this study was to evaluate clinical signs, gas analysis, and metabolic effects of diarrhea in milk-fed calves consuming starter feed containing citrus pulp (CP as a replacement for corn. Twenty-four newborn Holstein male calves were distributed into treatments according to starter composition: (1 0% CP, (2 32% CP, (3 64% CP, on dry matter basis. The calves were housed in individual hutches, with free access to water and concentrate, and received 4 L/d of milk replacer. After diarrhea diagnosis, evaluations of fecal score, score of clinical signs and measurement of physiological parameters were performed three times a day during 3-d. Blood samples were collected for electrolytes, blood gases, and plasma biochemical analysis. Starter feed composition had no negative effect (P>0.05 on fecal score, characteristics of diarrheic stools and on the aggravation of diarrhea clinical signs. Biochemical, blood gases and electrolytes changes, as a function of starter composition, did not resulted (P>0.05 in dehydration, acidosis, or other metabolic disturbance animals. Total lactate and D-lactate plasma concentrations were higher for calves on control and 64% CP, and L-lactate was highest for the 64% CP; however, calves showed no signs of metabolic acidosis. Thermal comfort indexes influenced clinical and physiological parameters (P<0.05. Citrus pulp may replace corn in starter composition without prejudice to intestinal health or metabolism of young diarrheic calves.

  8. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  9. Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.

    Science.gov (United States)

    Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V

    2017-07-01

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2  = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. No early effect of storage time of transfused red blood cells on fatigue and plasma cytokines in patients with anaemia from non-acute gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Mynster, Tommie; Dziegiel, Morten H; Kofoed, Kristian

    2007-01-01

    Background: Fatigue in anaemia is empirically reduced by blood transfusion. Long storage time of red cells may be associated with immunomodulatory effects, and blood stored for a long time may cause tissue hypoxia upon transfusion. Patients and Methods: 22 patients admitted with haemoglobin ... scale. Clinical observations and blood samples were obtained before transfusion was started, and were repeated 2-8 h after transfusion of the 2nd unit. Measured plasma parameters included IL- 1ß, IL-6, IL-8, IL-10, IL-12 and TNF-a. Results: There were no significant differences between group S and L (ns......SL) in demographic data, observational data and blood plasma values. Haemoglobin increased from mean (± SD) 5.2 ± 0.6 to 6.4 ± 0.7 mmol/l after transfusion (nsSL). Fatigue score significantly decreased from a pre-transfusion median 6.6 (range 0.1-9.9) to post-transfusion 4.7 (0.6-10.0) (p = 0.02) for all patients...

  11. Typical parameters of the plasma chemical similarity in non-isothermal reactive plasmas

    International Nuclear Information System (INIS)

    Gundermann, S.; Jacobs, H.; Miethke, F.; Rutsher, A.; Wagner, H.E.

    1996-01-01

    The substance of physical similarity principles is contained in parameters which govern the comparison of different realizations of a model device. Because similarity parameters for non-isothermal plasma chemical reactors are unknown to a great extent, an analysis of relevant equations is given together with some experimental results. Modelling of the reactor and experimental results for the ozone synthesis are presented

  12. Substrate Effect on Plasma Clean Efficiency in Plasma Enhanced Chemical Vapor Deposition System

    Directory of Open Access Journals (Sweden)

    Shiu-Ko JangJian

    2007-01-01

    Full Text Available The plasma clean in a plasma-enhanced chemical vapor deposition (PECVD system plays an important role to ensure the same chamber condition after numerous film depositions. The periodic and applicable plasma clean in deposition chamber also increases wafer yield due to less defect produced during the deposition process. In this study, the plasma clean rate (PCR of silicon oxide is investigated after the silicon nitride deposited on Cu and silicon oxide substrates by remote plasma system (RPS, respectively. The experimental results show that the PCR drastically decreases with Cu substrate compared to that with silicon oxide substrate after numerous silicon nitride depositions. To understand the substrate effect on PCR, the surface element analysis and bonding configuration are executed by X-ray photoelectron spectroscopy (XPS. The high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS is used to analyze microelement of metal ions on the surface of shower head in the PECVD chamber. According to Cu substrate, the results show that micro Cu ion and the CuOx bonding can be detected on the surface of shower head. The Cu ion contamination might grab the fluorine radicals produced by NF3 ddissociation in the RPS and that induces the drastic decrease on PCR.

  13. DYNAMIC OF CHANGES OF BLOOD PLASMA ENERGY METABOLISM PARAMETERS IN SUCKLING COWS DURING CALVING INTERVAL

    Directory of Open Access Journals (Sweden)

    Ales Pavlik

    2015-02-01

    Full Text Available In this study, effect of environmental condition changes during gazing period on energy metabolism parameters was investigated. Totally 40 Aberdeen Angus cows were selected for observation. Calving all of cows was situated into March. The feeding ration for the animals was comprised by pasture during the grazing period and corn silage, hay and granulated distiller’s grains during the winter period. At average age 9 days before calving, and subsequently 10, 81, 151, 189 and 273 days after calving, blood was sampled and analysed for glucose and NEFA (non-esterified fatty acid concentrations on KONELAB T20xt automatic analyser (Thermo Fisher Scientific, Finland and currently available commercial kits (Biovendor-Laboratorni medicina, Czech Republic. A rapid increase (p < 0.05 of glucose concentration was detected in blood plasma of cows in period before calving to 81 days post partum. Average value of glucose concentration at 273 days postpartum was significant (p < 0.05 lower comparing to day 189. The highest concentrations of NEFA in blood plasma of cows were found at 10 day postpartum. After that, during the persisted higher temperature period the NEFA concentration decreased significantly (p < 0.01 till 189 days postpartum. At the end of monitored period concentration of NEFA in blood plasma significantly decreased (p < 0.05. Changes of hot and cold season during the grazing period probably according to forage quality and had significant effects on blood plasma NEFA and glucose concentrations.

  14. Disturbance of binding of corticosteroids with blood plasma proteins during acute radiation sickness of different experimental animals

    International Nuclear Information System (INIS)

    Moroz, B.B.; Omel'chuk, N.N.

    1979-01-01

    In experiments on different animals a study was made of the effect of total-body γ-irradiation on binding of corticosteroids with blood plasma proteins. It was demonstrated that the increase in the number of physiologically active corticosteroids at the peak of radiation sickness is due to diminution of linking ability of corticosteroid-binding globulin of blood plasma and independent ot the total concentration of hormones in blood which is, evidently, a general radiobiological law

  15. [Demography and donation frequencies of blood and plasma donor populations in Germany. Update 2010 and 5-year comparison].

    Science.gov (United States)

    Ritter, S; Hamouda, O; Offergeld, R

    2012-08-01

    The Robert Koch Institute collects and evaluates nationwide data on the incidence and prevalence of transfusion-relevant infections among blood and plasma donors in Germany. Since 2006 data not only on the number of donations tested but also on the number of the respective donors have become available. The demographic profile and donation frequencies of German whole blood, plasma and platelet donors in 2010 and the percentages among the general population are described and compared to data from 2006. Although the general population eligible to donate blood is on the decline since 2003, with a loss of 2% between 2006 and 2010, this has not led to a decrease in the number of blood donors and donations. Instead, the number of new and repeat whole blood donors increased by 8% and 7%, respectively. At the same time, the number of new plasma donors grew by 23%, that of repeat plasma donors by 41%. In 2010 more than 4.3% of the population aged 18-68 years was active as repeat whole blood donors; 0.4% repeatedly donated plasma or platelets. Since 2006 the percentage of donors among the general population increased significantly, especially among the youngest age group (18-24 years). Donation frequency varied depending on donor age and sex, with an average of 1.9 per year for whole blood donations, 12.5 for plasmapheresis and 5.0 for plateletpheresis. While the donation frequency for whole blood remained unchanged since 2006, the frequency of apheresis donations increased, especially among older donors. By recruiting more new donors and retaining and reactivating existing ones more effectively, the number of whole blood and apheresis donations was augmented.

  16. Destruction of chemical warfare surrogates using a portable atmospheric pressure plasma jet

    Science.gov (United States)

    Škoro, Nikola; Puač, Nevena; Živković, Suzana; Krstić-Milošević, Dijana; Cvelbar, Uroš; Malović, Gordana; Petrović, Zoran Lj.

    2018-01-01

    Today's reality is connected with mitigation of threats from the new chemical and biological warfare agents. A novel investigation of cold plasmas in contact with liquids presented in this paper demonstrated that the chemically reactive environment produced by atmospheric pressure plasma jet (APPJ) is potentially capable of rapid destruction of chemical warfare agents in a broad spectrum. The decontamination of three different chemical warfare agent surrogates dissolved in liquid is investigated by using an easily transportable APPJ. The jet is powered by a kHz signal source connected to a low-voltage DC source and with He as working gas. The detailed investigation of electrical properties is performed for various plasmas at different distances from the sample. The measurements of plasma properties in situ are supported by the optical spectrometry measurements, whereas the high performance liquid chromatography measurements before and after the treatment of aqueous solutions of Malathion, Fenitrothion and Dimethyl Methylphosphonate. These solutions are used to evaluate destruction and its efficiency for specific neural agent simulants. The particular removal rates are found to be from 56% up to 96% during 10 min treatment. The data obtained provide basis to evaluate APPJ's efficiency at different operating conditions. The presented results are promising and could be improved with different operating conditions and optimization of the decontamination process.

  17. Knowledge, attitude and practice of exercise for plasma blood glucose control among patients with type-2 diabetes.

    Science.gov (United States)

    Awotidebe, Taofeek O; Adedoyin, Rufus A; Afolabi, Mubaraq A; Opiyo, Rose

    2016-01-01

    Exercise plays significant role in the health outcomes of patients with diabetes, however, little is known about patients' knowledge of exercise for plasma blood glucose control among patients with type-2 diabetes (T2D). This study investigated knowledge, attitude and practice (KAP) of exercise for plasma blood glucose control among patients with T2D. This cross-sectional study recruited 299 patients with T2D (male=105; female=194) from selected government hospitals in Osun State, Nigeria using purposive sampling technique. Validated questionnaires were used to assess of exercise for plasma blood glucose control and socioeconomic status (SES) of the patients. Data were analysed using descriptive and inferential statistics. Alpha level was set at exercise whilst 269(90.0%) had negative attitude to exercise practice. Less than a third, 82(27.4%) engaged in exercise practice for plasma blood glucose control. There was significant association between knowledge and practice of exercise ((2)=12.535; p=0.002). Furthermore, significant associations were found between knowledge and gender ((2)=11.453; p=0.003), and socioeconomic status ((2)=29.127, p=0.001) but not associated with attitude towards exercise (p>0.05). Patients with demonstrated good knowledge of exercise for plasma blood glucose control but reported negative attitude and poor practice of exercise. Copyright © 2016. Published by Elsevier Ltd.

  18. Determination of cortisol in blood plasma by isotopic dilution

    International Nuclear Information System (INIS)

    Shimizu, T.

    1978-01-01

    A method to measure cortisol in blood plasma is developed using tritium a tracer. Thin-layer chromatographer is used for very accurate separation and determination of cortisol free of impurities. Results show a concentration of 14,02+-5,79 μg/100ml for cortisol in blod. This method appears to be especially useful when interfering substances are present [pt

  19. Hydrodynamic chromatography coupled to single-particle ICP-MS for the simultaneous characterization of AgNPs and determination of dissolved Ag in plasma and blood of burn patients.

    Science.gov (United States)

    Roman, Marco; Rigo, Chiara; Castillo-Michel, Hiram; Munivrana, Ivan; Vindigni, Vincenzo; Mičetić, Ivan; Benetti, Federico; Manodori, Laura; Cairns, Warren R L

    2016-07-01

    Silver nanoparticles (AgNPs) are increasingly used in medical devices as innovative antibacterial agents, but no data are currently available on their chemical transformations and fate in vivo in the human body, particularly on their potential to reach the circulatory system. To study the processes involving AgNPs in human plasma and blood, we developed an analytical method based on hydrodynamic chromatography (HDC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) in single-particle detection mode. An innovative algorithm was implemented to deconvolute the signals of dissolved Ag and AgNPs and to extrapolate a multiparametric characterization of the particles in the same chromatogram. From a single injection, the method provides the concentration of dissolved Ag and the distribution of AgNPs in terms of hydrodynamic diameter, mass-derived diameter, number and mass concentration. This analytical approach is robust and suitable to study quantitatively the dynamics and kinetics of AgNPs in complex biological fluids, including processes such as agglomeration, dissolution and formation of protein coronas. The method was applied to study the transformations of AgNP standards and an AgNP-coated dressing in human plasma, supported by micro X-ray fluorescence (μXRF) and micro X-ray absorption near-edge spectroscopy (μXANES) speciation analysis and imaging, and to investigate, for the first time, the possible presence of AgNPs in the blood of three burn patients treated with the same dressing. Together with our previous studies, the results strongly support the hypothesis that the systemic mobilization of the metal after topical administration of AgNPs is driven by their dissolution in situ. Graphical Abstract Simplified scheme of the combined analytical approach adopted for studying the chemical dynamics of AgNPs in human plasma/blood.

  20. Metabolomics as a tool for discovery of biomarkers of autism spectrum disorder in the blood plasma of children.

    Directory of Open Access Journals (Sweden)

    Paul R West

    Full Text Available The diagnosis of autism spectrum disorder (ASD at the earliest age possible is important for initiating optimally effective intervention. In the United States the average age of diagnosis is 4 years. Identifying metabolic biomarker signatures of ASD from blood samples offers an opportunity for development of diagnostic tests for detection of ASD at an early age.To discover metabolic features present in plasma samples that can discriminate children with ASD from typically developing (TD children. The ultimate goal is to identify and develop blood-based ASD biomarkers that can be validated in larger clinical trials and deployed to guide individualized therapy and treatment.Blood plasma was obtained from children aged 4 to 6, 52 with ASD and 30 age-matched TD children. Samples were analyzed using 5 mass spectrometry-based methods designed to orthogonally measure a broad range of metabolites. Univariate, multivariate and machine learning methods were used to develop models to rank the importance of features that could distinguish ASD from TD.A set of 179 statistically significant features resulting from univariate analysis were used for multivariate modeling. Subsets of these features properly classified the ASD and TD samples in the 61-sample training set with average accuracies of 84% and 86%, and with a maximum accuracy of 81% in an independent 21-sample validation set.This analysis of blood plasma metabolites resulted in the discovery of biomarkers that may be valuable in the diagnosis of young children with ASD. The results will form the basis for additional discovery and validation research for 1 determining biomarkers to develop diagnostic tests to detect ASD earlier and improve patient outcomes, 2 gaining new insight into the biochemical mechanisms of various subtypes of ASD 3 identifying biomolecular targets for new modes of therapy, and 4 providing the basis for individualized treatment recommendations.

  1. Metabolomics as a Tool for Discovery of Biomarkers of Autism Spectrum Disorder in the Blood Plasma of Children

    Science.gov (United States)

    West, Paul R.; Amaral, David G.; Bais, Preeti; Smith, Alan M.; Egnash, Laura A.; Ross, Mark E.; Palmer, Jessica A.; Fontaine, Burr R.; Conard, Kevin R.; Corbett, Blythe A.; Cezar, Gabriela G.; Donley, Elizabeth L. R.; Burrier, Robert E.

    2014-01-01

    Background The diagnosis of autism spectrum disorder (ASD) at the earliest age possible is important for initiating optimally effective intervention. In the United States the average age of diagnosis is 4 years. Identifying metabolic biomarker signatures of ASD from blood samples offers an opportunity for development of diagnostic tests for detection of ASD at an early age. Objectives To discover metabolic features present in plasma samples that can discriminate children with ASD from typically developing (TD) children. The ultimate goal is to identify and develop blood-based ASD biomarkers that can be validated in larger clinical trials and deployed to guide individualized therapy and treatment. Methods Blood plasma was obtained from children aged 4 to 6, 52 with ASD and 30 age-matched TD children. Samples were analyzed using 5 mass spectrometry-based methods designed to orthogonally measure a broad range of metabolites. Univariate, multivariate and machine learning methods were used to develop models to rank the importance of features that could distinguish ASD from TD. Results A set of 179 statistically significant features resulting from univariate analysis were used for multivariate modeling. Subsets of these features properly classified the ASD and TD samples in the 61-sample training set with average accuracies of 84% and 86%, and with a maximum accuracy of 81% in an independent 21-sample validation set. Conclusions This analysis of blood plasma metabolites resulted in the discovery of biomarkers that may be valuable in the diagnosis of young children with ASD. The results will form the basis for additional discovery and validation research for 1) determining biomarkers to develop diagnostic tests to detect ASD earlier and improve patient outcomes, 2) gaining new insight into the biochemical mechanisms of various subtypes of ASD 3) identifying biomolecular targets for new modes of therapy, and 4) providing the basis for individualized treatment

  2. Fe3O4@ZnO core-shell nanocomposites for efficient and repetitive removal of low density lipoprotein in plasma and on blood vessel

    International Nuclear Information System (INIS)

    Huang, Xiao; Lu, Juan; Yue, Danyang; Fan, Yijuan; Yi, Caixia; Wang, Xiaoying; Zhang, Mengxue; Pan, Jun

    2015-01-01

    Low density lipoprotein (LDL)-apheresis therapy, which directly removes LDL from plasma by LDL-adsorbents in vitro is found to be clinically effective and safe to lower the LDL content in blood to prevent cardiovascular disease. Thus, developing excellent LDL adsorbents are becoming more and more attractive. Herein, functional Fe 3 O 4 @ZnO core–shell nanocomposites have been synthesized by a facile and eco-friendly two-step method. Not only do they possess high LDL adsorption (in PBS/plasma as well as on blood vessels) and favorable magnetic targeting ability but they can also be reused conveniently, which offer the Fe 3 O 4 @ZnO core–shell nanocomposites significant potential in the removal of LDL in vitro and in vivo. (paper)

  3. Effect of PTA on blood pressure, renal plasma flow and renal venous renin activity in renovascular hypertension

    International Nuclear Information System (INIS)

    Arlart, I.P.; Dewitz, H. von; Rosenthal, J.

    1983-01-01

    Percutaneous transluminal angioplasty (PTA) is more and more accepted for interventional management of renal artery stenosis in hypertensive patients. This study was carried out to assess the behaviour of arterial blood-pressure, renal plasma flow and renal venous rening activity in renovascular hypertension following catheter dilatation. Using the data the possibility is calculated to predict the effect of PTA on blood pressure preinterventionally. The results demonstrate that a successful employment of PTA depends on a normal contralateral renal plasma flow and a normalization of plasma flow of the poststenotic kidney. Determination of plasma renin activity is only of restricted value. (orig.)

  4. Review: Plasma-enhanced chemical vapor deposition of nanocrystalline diamond

    Directory of Open Access Journals (Sweden)

    Katsuyuki Okada

    2007-01-01

    Full Text Available Nanocrystalline diamond films have attracted considerable attention because they have a low coefficient of friction and a low electron emission threshold voltage. In this paper, the author reviews the plasma-enhanced chemical vapor deposition (PE-CVD of nanocrystalline diamond and mainly focuses on the growth of nanocrystalline diamond by low-pressure PE-CVD. Nanocrystalline diamond particles of 200–700 nm diameter have been prepared in a 13.56 MHz low-pressure inductively coupled CH4/CO/H2 plasma. The bonding state of carbon atoms was investigated by ultraviolet-excited Raman spectroscopy. Electron energy loss spectroscopy identified sp2-bonded carbons around the 20–50 nm subgrains of nanocrystalline diamond particles. Plasma diagnostics using a Langmuir probe and the comparison with plasma simulation are also reviewed. The electron energy distribution functions are discussed by considering different inelastic interaction channels between electrons and heavy particles in a molecular CH4/H2 plasma.

  5. Photooptical response of the blood plasma to the low-intensity red light

    International Nuclear Information System (INIS)

    Mints, R.I.; Skopinov, S.A.; Yakovleva, S.V.

    1990-01-01

    Photooptical response to low-intensity red light by irradiation of the whole blood as well as of its pigmentless plasma part is investigated. It is shown by the example of blood irradiation that the mechanism of action of low-intensity red light on the blood is not directly related to pigmented molecular complexes. The conclusion is made, that the effect of low-intensity red light on living organisms includes mechanism not utilizing light absorption by a specialized molecule-photoreceptor as a primary photophysical act

  6. Microfluidic Devices for Blood Fractionation

    OpenAIRE

    Hou, Han Wei; Bhagat, Ali Asgar S.; Lee, Wong Cheng J.; Huang, Sha; Han, Jongyoon; Lim, Chwee Teck

    2011-01-01

    Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. ...

  7. A two-temperature chemical non-equilibrium modeling of DC arc plasma

    International Nuclear Information System (INIS)

    Qian Haiyang; Wu Bin

    2011-01-01

    To a better understanding of non-equilibrium characteristics of DC arc plasma,a two-dimensional axisymmetric two-temperature chemical non-equilibrium (2T-NCE) model is applied for direct current arc argon plasma generator with water-cooled constrictor at atmospheric pressure. The results show that the electron temperature and heavy particle temperature has a relationship under different working parameters, indicating that DC arc plasma has a strong non-equilibrium characteristic, and the variation is obvious. (authors)

  8. An integrated fluid-chemical model toward modeling the formation of intra-luminal thrombus in abdominal aortic aneurysms.

    Science.gov (United States)

    Biasetti, Jacopo; Spazzini, Pier Giorgio; Swedenborg, Jesper; Gasser, T Christian

    2012-01-01

    Abdominal Aortic Aneurysms (AAAs) are frequently characterized by the presence of an Intra-Luminal Thrombus (ILT) known to influence their evolution biochemically and biomechanically. The ILT progression mechanism is still unclear and little is known regarding the impact of the chemical species transported by blood flow on this mechanism. Chemical agonists and antagonists of platelets activation, aggregation, and adhesion and the proteins involved in the coagulation cascade (CC) may play an important role in ILT development. Starting from this assumption, the evolution of chemical species involved in the CC, their relation to coherent vortical structures (VSs) and their possible effect on ILT evolution have been studied. To this end a fluid-chemical model that simulates the CC through a series of convection-diffusion-reaction (CDR) equations has been developed. The model involves plasma-phase and surface-bound enzymes and zymogens, and includes both plasma-phase and membrane-phase reactions. Blood is modeled as a non-Newtonian incompressible fluid. VSs convect thrombin in the domain and lead to the high concentration observed in the distal portion of the AAA. This finding is in line with the clinical observations showing that the thickest ILT is usually seen in the distal AAA region. The proposed model, due to its ability to couple the fluid and chemical domains, provides an integrated mechanochemical picture that potentially could help unveil mechanisms of ILT formation and development.

  9. Effects of competitive red blood cell binding and reduced hematocrit on the blood and plasma levels of [14C]Indapamide in the rat

    International Nuclear Information System (INIS)

    Lettieri, J.T.; Portelli, S.T.

    1983-01-01

    The effects of chlorthalidone and acetazolamide on the red blood cell binding of indapamide were investigated. Both drugs caused a substantial decrease in the amount of indapamide bound to the erythrocytes in vitro. This effect was demonstrated by a change in the indapamide blood/plasma ratio from approximately 6 in control samples, to a value of 1 when either of the displacing agents was added. Coadministration of acetazolamide with 14 C-labeled indapamide to rats, resulted in a 5-fold drop in the blood levels of total radioactivity, relative to rats dosed with [ 14 C]indapamide alone. Concomitantly, there was a 2-fold increase in the plasma levels of total radioactivity after acetazolamide coadministration. In rats whose hematocrits had been reduced by extensive bleeding, there were only minor alterations in the blood/plasma partitioning of [ 14 C]indapamide. Thus, chlorthalidone and acetazolamide were able to displace indapamide from erythrocytes in vitro and in vivo, possibly by competition at a carbonic anhydrase binding site. The pharmacokinetics of drugs which are extensively bound to erythrocytes may be significantly altered by the presence of other agents capable of competitive binding

  10. Characteristics of nanosized zirconia prepared by plasma and chemical technique

    International Nuclear Information System (INIS)

    Kuznetsova, L.; Grabis, J.; Heidemane, G.

    2003-01-01

    The studied preparation method of zirconia using the plasma technique, azeotropic distillation and glycine routes ensure obtaining of nano sized powders with close average particle size but different crystallite size and phase composition. The sinterability of nano sized zirconia particles prepared by plasma technique or wet-chemical methods is similar and depends on the green density of pressed powders, improvement of with can be achieved by using of granulated precursors. (authors)

  11. Distinct kinetics of memory B-cell and plasma-cell responses in peripheral blood following a blood-stage Plasmodium chabaudi infection in mice.

    Directory of Open Access Journals (Sweden)

    Eunice W Nduati

    2010-11-01

    Full Text Available B cell and plasma cell responses take place in lymphoid organs, but because of the inaccessibility of these organs, analyses of human responses are largely performed using peripheral blood mononuclear cells (PBMC. To determine whether PBMC are a useful source of memory B cells and plasma cells in malaria, and whether they reflect Plasmodium-specific B cell responses in spleen or bone marrow, we have investigated these components of the humoral response in PBMC using a model of Plasmodium chabaudi blood-stage infections in C57BL/6 mice. We detected memory B cells, defined as isotype-switched IgD(- IgM(- CD19(+ B cells, and low numbers of Plasmodium chabaudi Merozoite Surface Protein-1 (MSP1-specific memory B cells, in PBMC at all time points sampled for up to 90 days following primary or secondary infection. By contrast, we only detected CD138(+ plasma cells and MSP1-specific antibody-secreting cells within a narrow time frame following primary (days 10 to 25 or secondary (day 10 infection. CD138(+ plasma cells in PBMC at these times expressed CD19, B220 and MHC class II, suggesting that they were not dislodged bone-marrow long-lived plasma cells, but newly differentiated migratory plasmablasts migrating to the bone marrow; thus reflective of an ongoing or developing immune response. Our data indicates that PBMC can be a useful source for malaria-specific memory B cells and plasma cells, but extrapolation of the results to human malaria infections suggests that timing of sampling, particularly for plasma cells, may be critical. Studies should therefore include multiple sampling points, and at times of infection/immunisation when the B-cell phenotypes of interest are likely to be found in peripheral blood.

  12. Decreased material-activation of the complement system using low-energy plasma polymerized poly(vinyl pyrrolidone) coatings

    DEFF Research Database (Denmark)

    Andersen, T.E.; Kolmos, H.J.; Palarasah, Yaseelan

    2011-01-01

    In the current study we investigate the activation of blood complement on medical device silicone rubber and present a plasma polymerized vinyl pyrrolidone (ppVP) coating which strongly decreases surface-activation of the blood complement system. We show that uncoated silicone and polystyrene...... surface. The ppVP surface is furthermore characterized physically and chemically using scanning electron microscopy (SEM), x-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR), which indicates preservation of chemical functionality by the applied plasma process. Overall, the pp...

  13. Blood and Plasma Biochemistry Reference Intervals for Wild Juvenile American Alligators ( Alligator mississippiensis ).

    Science.gov (United States)

    Hamilton, Matthew T; Kupar, Caitlin A; Kelley, Meghan D; Finger, John W; Tuberville, Tracey D

    2016-07-01

    : American alligators ( Alligator mississippiensis ) are one of the most studied crocodilian species in the world, yet blood and plasma biochemistry information is limited for juvenile alligators in their northern range, where individuals may be exposed to extreme abiotic and biotic stressors. We collected blood samples over a 2-yr period from 37 juvenile alligators in May, June, and July to establish reference intervals for 22 blood and plasma analytes. We observed no effect of either sex or blood collection time on any analyte investigated. However, our results indicate a significant correlation between a calculated body condition index and aspartate aminotransferase and creatine kinase. Glucose, total protein, and potassium varied significantly between sampling sessions. In addition, glucose and potassium were highly correlated between the two point-of-care devices used, although they were significantly lower with the i-STAT 1 CG8+ cartridge than with the Vetscan VS2 Avian/Reptile Rotor. The reference intervals presented herein should provide baseline data for evaluating wild juvenile alligators in the northern portion of their range.

  14. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  15. Experimental setup for producing tungsten coated graphite tiles using plasma enhanced chemical vapor deposition technique for fusion plasma applications

    International Nuclear Information System (INIS)

    Chauhan, Sachin Singh; Sharma, Uttam; Choudhary, K.K.; Sanyasi, A.K.; Ghosh, J.; Sharma, Jayshree

    2013-01-01

    Plasma wall interaction (PWI) in fusion grade machines puts stringent demands on the choice of materials in terms of high heat load handling capabilities and low sputtering yields. Choice of suitable material still remains a challenge and open topic of research for the PWI community. Carbon fibre composites (CFC), Beryllium (Be), and Tungsten (W) are now being considered as first runners for the first wall components of future fusion machines. Tungsten is considered to be one of the suitable materials for the job because of its superior properties than carbon like low physical sputtering yield and high sputter energy threshold, high melting point, fairly high re-crystallization temperature, low fuel retention capabilities, low chemical sputtering with hydrogen and its isotopes and most importantly the reparability with various plasma techniques both ex-situ and in-situ. Plasma assisted chemical vapour deposition is considered among various techniques as the most preferable technique for fabricating tungsten coated graphite tiles to be used as tokamak first wall and target components. These coated tiles are more favourable compared to pure tungsten due to their light weight and easier machining. A system has been designed, fabricated and installed at SVITS, Indore for producing tungsten coated graphite tiles using Plasma Enhanced Chemical Vapor Deposition (PE-CVD) technique for Fusion plasma applications. The system contains a vacuum chamber, a turbo-molecular pump, two electrodes, vacuum gauges, mass analyzer, mass flow controllers and a RF power supply for producing the plasma using hydrogen gas. The graphite tiles will be put on one of the electrodes and WF6 gas will be inserted in a controlled manner in the hydrogen plasma to achieve the tungsten-coating with WF6 dissociation. The system is integrated at SVITS, Indore and a vacuum of the order of 3*10 -6 is achieved and glow discharge plasma has been created to test all the sub-systems. The system design with

  16. Chemical and physical reactions under thermal plasmas conditions

    International Nuclear Information System (INIS)

    Fauchais, P.; Vardelle, A.; Vardelle, M.; Coudert, J.F.

    1987-01-01

    Basic understanding of the involved phenomena lags far behind industrial development that requires now a better knowledge of the phenomena to achieve a better control of the process allowing to improve the quality of the products. Thus the authors try to precise what is their actual knowledge in the fields of: plasma generators design; plasma flow models with the following key points: laminar or turbulent flow, heat transfer to walls, 2D or 3D models, non equilibrium effects, mixing problems when chemical reactions are to be taken into account with very fast kinetics, electrode regions, data for transport properties and kinetic rates; nucleation problems; plasma flow characteristics measurements: temperature or temperatures and population of excited states (automatized emission spectroscopy, LIF, CARS) as well as flow velocity (LDA with small particles, Doppler effects...); plasma and particles momentum and heat transfer either with models taking into account particles size and injection velocity distributions, heat propagation, vaporization, Kundsen effect, turbulences ... or with measurements: particles velocity and flux distributions (Laser Anemometry) as well as surface temperature distributions (two colour pyrometry in flight statistical or not)

  17. Frozen blood products: clinically effective and potentially ideal for remote Australia.

    Science.gov (United States)

    Holley, A; Marks, D C; Johnson, L; Reade, M C; Badloe, J F; Noorman, F

    2013-01-01

    The development of effective cryopreservation techniques for both red blood cells and platelets, which maintain ex vivo biological activity, in combination with frozen plasma, provides for a unique blood banking strategy. This technology greatly enhances the storage life of these products. The rationale and potential advantages of using cryopreservation techniques for the provision of blood products to remote and military environments have been effectively demonstrated in several conflicts over the last decade. Current haemostatic resuscitation doctrine for the exsanguinating patient supports the use of red blood cells, platelets and frozen plasma early in the resuscitation. We believe an integrated fresh-frozen blood bank inventory could facilitate provision of blood products, not only in the military setting but also in regional Australia, by overcoming many logistic and geographical challenges. The processes involved in production and point of care thawing are sufficiently well developed and achievable to make this technology a viable option. The potential limitations of cryopreservation and subsequent product thawing need to be considered if such a strategy is to be developed. A substantial body of international experience using cryopreserved products in remote settings has already been accrued. This experience provides a template for the possible creation of an Australian integrated fresh-frozen blood bank inventory that could conceivably enhance the care of patients in both regional Australia and in the military setting.

  18. The characterization of exosome from blood plasma of patients with colorectal cancer

    International Nuclear Information System (INIS)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Afanas’ev, S. G.; Kondakova, I. V.; Frolova, A. Y.

    2016-01-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The clarification of the criteria for exosome isolating and identifying is the purpose of this study. Exosome samples from the plasma of patients with colorectal cancer and healthy donors were examined using transmission electron microscopy and flow cytometry in accordance with the minimum requirements of “International Society for Extracellular Vesicles”. The choice of the method for isolation of exosomes from the blood plasma by ultrafiltration and ultracentrifugation allowed obtaining highly purified samples of exosomes, in which all the structural components were clearly seen. The results obtained with flow cytometry suggest that exosomes of blood plasma from patients with colorectal cancer can be produced by epithelial cells. Moreover, cells produce different types of exosomes, which correspond to different mechanisms in sorting macromolecules in the membrane of multivesicular bodies. Determination of significant differences in the expression of specific exosomal proteins from colorectal cancer patients compared to healthy donors suggests a high diagnostic potential significance of circulating exosomes.

  19. The characterization of exosome from blood plasma of patients with colorectal cancer

    Science.gov (United States)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Afanas'ev, S. G.; Frolova, A. Y.; Kondakova, I. V.

    2016-08-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The clarification of the criteria for exosome isolating and identifying is the purpose of this study. Exosome samples from the plasma of patients with colorectal cancer and healthy donors were examined using transmission electron microscopy and flow cytometry in accordance with the minimum requirements of "International Society for Extracellular Vesicles". The choice of the method for isolation of exosomes from the blood plasma by ultrafiltration and ultracentrifugation allowed obtaining highly purified samples of exosomes, in which all the structural components were clearly seen. The results obtained with flow cytometry suggest that exosomes of blood plasma from patients with colorectal cancer can be produced by epithelial cells. Moreover, cells produce different types of exosomes, which correspond to different mechanisms in sorting macromolecules in the membrane of multivesicular bodies. Determination of significant differences in the expression of specific exosomal proteins from colorectal cancer patients compared to healthy donors suggests a high diagnostic potential significance of circulating exosomes.

  20. The characterization of exosome from blood plasma of patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yunusova, N. V., E-mail: Bochkarevanv@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634009 (Russian Federation); Siberian State Medical University, Moskovsky Trakt 2, Tomsk, 634050 (Russian Federation); Tamkovich, S. N., E-mail: s.tamk@niboch.nsc.ru [Institute of Chemical Biology and Fundamental Medicine SB RAS, Lavrentiev Avenue 8, Novosibirsk, 630090 (Russian Federation); Novosibirsk State University, Pirogov Street 2, Novosibirsk, 630090 (Russian Federation); Stakheeva, M. N., E-mail: StakheyevaM@oncology.tomsk.ru; Afanas’ev, S. G., E-mail: Afanasievsg@oncology.tomsk.ru; Kondakova, I. V., E-mail: Kondakova@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634009 (Russian Federation); Frolova, A. Y., E-mail: Frolovalenya@mail.ru [Siberian State Medical University, Moskovsky Trakt 2, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The clarification of the criteria for exosome isolating and identifying is the purpose of this study. Exosome samples from the plasma of patients with colorectal cancer and healthy donors were examined using transmission electron microscopy and flow cytometry in accordance with the minimum requirements of “International Society for Extracellular Vesicles”. The choice of the method for isolation of exosomes from the blood plasma by ultrafiltration and ultracentrifugation allowed obtaining highly purified samples of exosomes, in which all the structural components were clearly seen. The results obtained with flow cytometry suggest that exosomes of blood plasma from patients with colorectal cancer can be produced by epithelial cells. Moreover, cells produce different types of exosomes, which correspond to different mechanisms in sorting macromolecules in the membrane of multivesicular bodies. Determination of significant differences in the expression of specific exosomal proteins from colorectal cancer patients compared to healthy donors suggests a high diagnostic potential significance of circulating exosomes.

  1. Platelet-rich plasma differs according to preparation method and human variability.

    Science.gov (United States)

    Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Cote, Mark P; Romeo, Anthony A; Bradley, James P; Arciero, Robert A; Beitzel, Knut

    2012-02-15

    Varying concentrations of blood components in platelet-rich plasma preparations may contribute to the variable results seen in recently published clinical studies. The purposes of this investigation were (1) to quantify the level of platelets, growth factors, red blood cells, and white blood cells in so-called one-step (clinically used commercial devices) and two-step separation systems and (2) to determine the influence of three separate blood draws on the resulting components of platelet-rich plasma. Three different platelet-rich plasma (PRP) separation methods (on blood samples from eight subjects with a mean age [and standard deviation] of 31.6 ± 10.9 years) were used: two single-spin processes (PRPLP and PRPHP) and a double-spin process (PRPDS) were evaluated for concentrations of platelets, red and white blood cells, and growth factors. Additionally, the effect of three repetitive blood draws on platelet-rich plasma components was evaluated. The content and concentrations of platelets, white blood cells, and growth factors for each method of separation differed significantly. All separation techniques resulted in a significant increase in platelet concentration compared with native blood. Platelet and white blood-cell concentrations of the PRPHP procedure were significantly higher than platelet and white blood-cell concentrations produced by the so-called single-step PRPLP and the so-called two-step PRPDS procedures, although significant differences between PRPLP and PRPDS were not observed. Comparing the results of the three blood draws with regard to the reliability of platelet number and cell counts, wide variations of intra-individual numbers were observed. Single-step procedures are capable of producing sufficient amounts of platelets for clinical usage. Within the evaluated procedures, platelet numbers and numbers of white blood cells differ significantly. The intra-individual results of platelet-rich plasma separations showed wide variations in

  2. Pathophysiology of infectious hematopoietic necrosis virus disease in rainbow trout: hematological and blood chemical changes in moribund fish

    Science.gov (United States)

    Amend, D.F.; Smith, L.

    1975-01-01

    Infectious hematopoietic necrosis (IHN) is a rhabdoviral disease of rainbow trout (Salmo gairdneri). Trout were injected with IHNV, and various hematological and biochemical measurements of clinically ill fish were compared to uninfected controls. Infected fish had reduced corpuscular counts, hemoglobin, and packed cell volume, but normal mean corpuscular volume, mean corpuscular hemoglobin, and mean corpuscular hemoglobin concentration. The percentage of immature erythrocytes was increased, but the percentage of leukocytes was unchanged. Differential leukocyte counts showed a significant decrease in neutrophils, increase in lymphocytes, but no change in monocytes. Unidentifiable necrobiotic cells were prevelant in blood smears and hematopoietic tissue imprints. Plasma bicarbonate, chloride, calcium, phosphorus, bilirubin, and osmolality were significantly reduced, but plasma glucose and anterior kidney ascorbate were unchanged. Plasma pH increased and the alpha fractions of the serum proteins were altered. No change was found in plasma enzymes, except that a LDH isozyme was significantly increased. The alkali reserve was diminished and alterations in acid-base and fluid balance occurred. Death probably resulted from a severe electrolyte and fluid imbalance caused by renal failure.

  3. Evaluation of mechanism of non-thermal plasma effect on the surface of polypropylene films for enhancement of adhesive and hemo compatible properties

    Energy Technology Data Exchange (ETDEWEB)

    Navaneetha Pandiyaraj, K., E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T by pass, Chinniyam Palayam (post), Coimbatore-641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai-400 019 (India); Arunkumar, A.; Ramkumar, M.C. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T by pass, Chinniyam Palayam (post), Coimbatore-641062 (India); Ruzybayev, I.; Ismat Shah, S. [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Su, Pi-Guey [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Periayah, Mercy Halleluyah; Halim, A.S. [School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2015-08-30

    Highlights: • Investigated the mechanism of effect of various gaseous plasma treatments on the surface properties of Polypropylene (PP) films. • The improvement in surface energy is basically due to the incorporation of polar functional groups onto the PP films. • The extent of surface modification and hydrophobic recovery depends upon the type of plasma forming gas. • Due to the significant morphological and chemical changes induced by the gaseous plasma treatment, improved the blood compatibility as well as adhesive strength of the PP films. - Abstract: The hydro-carbon based polymers have attracted attention of scientists for its use in bio-medical field as various implants due to inherent flexibility. However, they have poor surface properties; particularly they have low surface energy (SE). Hence, blood components (platelets, blood proteins, etc.)-polymer surface interaction is the major concern when it comes in contact with blood. Thus, surface modification is required to develop the perfect antithrombogenic property without affecting the materials bulk. The present study describes the improvement in adhesive and blood compatible properties of polypropylene (PP) by low temperature (non-thermal) plasma of various gases such as Ar, O{sub 2}, air and Ar + O{sub 2} for biomedical applications. The changes in surface morphological, chemical and hydrophilic modification induced by the gaseous plasma treatment were analyzed by atomic force microscopy (AFM), X-ray photo electron spectroscopy (XPS), electron spin resonance (ESR) spectroscopy and contact angle measurements, respectively. Moreover, the stability of plasma effect was also studied for the different storage conditions. Variation in adhesive strength of the plasma treated PP film was studied by T-Peel and Lap-Shear strength tests. The blood compatibility of the surface modified PP films was investigated by in vitro analysis. It was found that gaseous plasma treatment improved the blood compatibility

  4. Evaluation of mechanism of non-thermal plasma effect on the surface of polypropylene films for enhancement of adhesive and hemo compatible properties

    International Nuclear Information System (INIS)

    Navaneetha Pandiyaraj, K.; Deshmukh, R.R.; Arunkumar, A.; Ramkumar, M.C.; Ruzybayev, I.; Ismat Shah, S.; Su, Pi-Guey; Periayah, Mercy Halleluyah; Halim, A.S.

    2015-01-01

    Highlights: • Investigated the mechanism of effect of various gaseous plasma treatments on the surface properties of Polypropylene (PP) films. • The improvement in surface energy is basically due to the incorporation of polar functional groups onto the PP films. • The extent of surface modification and hydrophobic recovery depends upon the type of plasma forming gas. • Due to the significant morphological and chemical changes induced by the gaseous plasma treatment, improved the blood compatibility as well as adhesive strength of the PP films. - Abstract: The hydro-carbon based polymers have attracted attention of scientists for its use in bio-medical field as various implants due to inherent flexibility. However, they have poor surface properties; particularly they have low surface energy (SE). Hence, blood components (platelets, blood proteins, etc.)-polymer surface interaction is the major concern when it comes in contact with blood. Thus, surface modification is required to develop the perfect antithrombogenic property without affecting the materials bulk. The present study describes the improvement in adhesive and blood compatible properties of polypropylene (PP) by low temperature (non-thermal) plasma of various gases such as Ar, O 2 , air and Ar + O 2 for biomedical applications. The changes in surface morphological, chemical and hydrophilic modification induced by the gaseous plasma treatment were analyzed by atomic force microscopy (AFM), X-ray photo electron spectroscopy (XPS), electron spin resonance (ESR) spectroscopy and contact angle measurements, respectively. Moreover, the stability of plasma effect was also studied for the different storage conditions. Variation in adhesive strength of the plasma treated PP film was studied by T-Peel and Lap-Shear strength tests. The blood compatibility of the surface modified PP films was investigated by in vitro analysis. It was found that gaseous plasma treatment improved the blood compatibility as well

  5. Chemical modeling of a high-density inductively-coupled plasma reactor containing silane

    NARCIS (Netherlands)

    Kovalgin, Alexeij Y.; Boogaard, A.; Brunets, I.; Holleman, J.; Schmitz, Jurriaan

    We carried out the modeling of chemical reactions in a silane-containing remote Inductively Coupled Plasma Enhanced Chemical Vapor Deposition (ICPECVD) system, intended for deposition of silicon, silicon oxide, and silicon nitride layers. The required electron densities and Electron Energy

  6. The Effect of Rast Exercise on Plasma Levels of Apelin and Blood Pressure in Elite Women Runner

    Directory of Open Access Journals (Sweden)

    Shaibani Sh

    2012-09-01

    Full Text Available Background and Objectives: Intense exercise increases heart susceptibility to the disorder in this physiological factor.The purpose of this study is to study the effect of sprint interval training on plasma levels of apelin, blood pressure and heart rate in elite female runner. Methods: Plasma levels of apelin, Heart rate (HR & blood pressure (BP, analyzed before, after and 24 hours after exercise. 15 elite female runner, whom were playing in Shiraz track & field league, selected for this study. They all were homogenized according to any kind of disease.Results: Rast exercise made plasma level of Apelin decrease after exercise compared with plasma level before exercise and this decrease was significant (p=0.001. Also, plasma level of apelin increased significantly 24 hrs after finishing exercise (p=0.001, but there were no significant differences before exercise (p=0.375. Systolic blood pressure and heart rate increased immediately after exercise and decreased significantly after 24 hrs (p=0.001. However, significant difference was not observed in diastolic pressure before and after exercise (p=0.338.Conclusion: The finding of this study shows that sprint interval training decreases plasma levels of apelin, so we can say that apelin and blood pressure must be in balance in natural position. With knowing the role of apelin, changes in this peptide during exercise can be an alarm to cardiovascular risk factor, during or after exercise in elite athletes.

  7. Chemical Changes in Nonthermal Plasma-Treated N-Acetylcysteine (NAC) Solution and Their Contribution to Bacterial Inactivation.

    Science.gov (United States)

    Ercan, Utku K; Smith, Josh; Ji, Hai-Feng; Brooks, Ari D; Joshi, Suresh G

    2016-02-02

    In continuation of our previous reports on the broad-spectrum antimicrobial activity of atmospheric non-thermal dielectric barrier discharge (DBD) plasma treated N-Acetylcysteine (NAC) solution against planktonic and biofilm forms of different multidrug resistant microorganisms, we present here the chemical changes that mediate inactivation of Escherichia coli. In this study, the mechanism and products of the chemical reactions in plasma-treated NAC solution are shown. UV-visible spectrometry, FT-IR, NMR, and colorimetric assays were utilized for chemical characterization of plasma treated NAC solution. The characterization results were correlated with the antimicrobial assays using determined chemical species in solution in order to confirm the major species that are responsible for antimicrobial inactivation. Our results have revealed that plasma treatment of NAC solution creates predominantly reactive nitrogen species versus reactive oxygen species, and the generated peroxynitrite is responsible for significant bacterial inactivation.

  8. Temperature dependence on plasma-induced damage and chemical reactions in GaN etching processes using chlorine plasma

    Science.gov (United States)

    Liu, Zecheng; Ishikawa, Kenji; Imamura, Masato; Tsutsumi, Takayoshi; Kondo, Hiroki; Oda, Osamu; Sekine, Makoto; Hori, Masaru

    2018-06-01

    Plasma-induced damage (PID) on GaN was optimally reduced by high-temperature chlorine plasma etching. Energetic ion bombardments primarily induced PID involving stoichiometry, surface roughness, and photoluminescence (PL) degradation. Chemical reactions under ultraviolet (UV) irradiation and chlorine radical exposure at temperatures higher than 400 °C can be controlled by taking into account the synergism of simultaneous photon and radical irradiations to effectively reduce PID.

  9. Promising Metabolite Profiles in the Plasma and CSF of Early Clinical Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Daniel Stoessel

    2018-03-01

    Full Text Available Parkinson's disease (PD shows high heterogeneity with regard to the underlying molecular pathogenesis involving multiple pathways and mechanisms. Diagnosis is still challenging and rests entirely on clinical features. Thus, there is an urgent need for robust diagnostic biofluid markers. Untargeted metabolomics allows establishing low-molecular compound biomarkers in a wide range of complex diseases by the measurement of various molecular classes in biofluids such as blood plasma, serum, and cerebrospinal fluid (CSF. Here, we applied untargeted high-resolution mass spectrometry to determine plasma and CSF metabolite profiles. We semiquantitatively determined small-molecule levels (≤1.5 kDa in the plasma and CSF from early PD patients (disease duration 0–4 years; n = 80 and 40, respectively, and sex- and age-matched controls (n = 76 and 38, respectively. We performed statistical analyses utilizing partial least square and random forest analysis with a 70/30 training and testing split approach, leading to the identification of 20 promising plasma and 14 CSF metabolites. These metabolites differentiated the test set with an AUC of 0.8 (plasma and 0.9 (CSF. Characteristics of the metabolites indicate perturbations in the glycerophospholipid, sphingolipid, and amino acid metabolism in PD, which underscores the high power of metabolomic approaches. Further studies will enable to develop a potential metabolite-based biomarker panel specific for PD.

  10. A Pilot Study Exploring the Plasma Potassium Variation in Dogs Undergoing Steroid Therapy and Its Clinical Importance.

    Science.gov (United States)

    Baltar, Marina; Costa, Alexandra; Carreira, L Miguel

    2016-06-01

    In most situations in veterinary medicine, glucocorticoids are the drugs of choice used, that is, to reduce the inflammatory response or limit an inappropriate immune response. Their use in long-term therapy may cause side effects that may weaken the patient. The aim of the study was to evaluate possible variations in the plasma potassium concentrations and their clinical relevance in dogs undergoing steroid therapy with methylprednisolone in anti-inflammatory doses. The study used a sample of 21 dogs (n = 21) presented for consultation, with a clinical condition requiring a corticosteroid therapeutic protocol with an anti-inflammatory dose of methylprednisolone. All the individuals were submitted to a corticosteroid therapeutic protocol administered orally during 18 days. During this period, 3 time points were considered: T0 (the day the prescription was first given), T1 (3 days later), and T2 (8 days later). Blood samples were collected from a peripheral vein to measure plasma potassium concentrations in T0, T1, and T2. Corticosteroid therapy on an outpatient basis statistically significantly decreased plasma potassium levels, especially between T1 and T2 (P = .03). The plasma potassium levels decreased in 12.5% of the males, compared with a decrease of 23.1% in the females. No statistically significant relationships were observe between the decreased plasma potassium levels and age, clinical condition, and patient׳s body weight. However, we found a statistically significant association between decreased plasma potassium levels and sex. The study results may justify the need for the systematic prescription of potassium supplements in patients undergoing steroid therapy, similar to what already occurs in human medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. A study of the potential of plasma processing in the chemical industry

    International Nuclear Information System (INIS)

    Estey, P.N.; Connolly, T.J.

    1984-01-01

    This work describes a systematic approach to determine the potential for plasma processing in the United States chemical industry. A model was developed that describes the physical inputs and outputs from a plasma based processing system. Based on these mass flows and the energy flows to the processor an economic assessment of the plasma processing system is made. This economic assessment which also includes the capital costs of the processor, can be used to determine if the plasma system is competitive with the conventional system

  12. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Science.gov (United States)

    Al-Marzoki, Jasim M; Al-Maaroof, Zainab W; Kadhum, Ali H

    2012-01-01

    Background The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. Methods A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. Results Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. Conclusion Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from

  13. Packed red blood cells are an abundant and proximate potential source of nitric oxide synthase inhibition.

    Directory of Open Access Journals (Sweden)

    Charles F Zwemer

    Full Text Available We determined, for packed red blood cells (PRBC and fresh frozen plasma, the maximum content, and ability to release the endogenous nitric oxide synthase (NOS inhibitors asymmetric dimethylarginine (ADMA and monomethylarginine (LNMMA.ADMA and LNMMA are near equipotent NOS inhibitors forming blood's total NOS inhibitory content. The balance between removal from, and addition to plasma determines their free concentrations. Removal from plasma is by well-characterized specific hydrolases while formation is restricted to posttranslational protein methylation. When released into plasma they can readily enter endothelial cells and inhibit NOS. Fresh rat and human whole blood contain substantial protein incorporated ADMA however; the maximum content of ADMA and LNMMA in PRBC and fresh frozen plasma has not been determined.We measured total (free and protein incorporated ADMA and LNMMA content in PRBCs and fresh frozen plasma, as well as their incubation induced release, using HPLC with fluorescence detection. We tested the hypothesis that PRBC and fresh frozen plasma contain substantial inhibitory methylarginines that can be released chemically by complete in vitro acid hydrolysis or physiologically at 37°C by enzymatic blood proteolysis.In vitro strong-acid-hydrolysis revealed a large PRBC reservoir of ADMA (54.5 ± 9.7 µM and LNMMA (58.9 ± 28.9 μM that persisted over 42-d at 6° or -80°C. In vitro 5h incubation at 37°C nearly doubled free ADMA and LNMMNA concentration from PRBCs while no change was detected in fresh frozen plasma.The compelling physiological ramifications are that regardless of storage age, 1 PRBCs can rapidly release pathologically relevant quantities of ADMA and LNMMA when incubated and 2 PRBCs have a protein-incorporated inhibitory methylarginines reservoir 100 times that of normal free inhibitory methylarginines in blood and thus could represent a clinically relevant and proximate risk for iatrogenic NOS inhibition upon

  14. Differential Impact of Plasma Proteins on the Adhesion Efficiency of Vascular-Targeted Carriers (VTCs) in Blood of Common Laboratory Animals.

    Science.gov (United States)

    Namdee, Katawut; Sobczynski, Daniel J; Onyskiw, Peter J; Eniola-Adefeso, Omolola

    2015-12-16

    Vascular-targeted carrier (VTC) interaction with human plasma is known to reduce targeted adhesion efficiency in vitro. However, the role of plasma proteins on the adhesion efficiency of VTCs in laboratory animals remains unknown. Here, in vitro blood flow assays are used to explore the effects of plasma from mouse, rabbit, and porcine on VTC adhesion. Porcine blood exhibited a strong negative plasma effect on VTC adhesion while no significant plasma effect was found with rabbit and mouse blood. A brush density poly(ethylene glycol) (PEG) on VTCs was effective at improving adhesion of microsized, but not nanosized, VTCs in porcine blood. Overall, the results suggest that porcine models, as opposed to mouse, can serve as better models in preclinical research for predicting the in vivo functionality of VTCs for use in humans. These considerations hold great importance for the design of various pharmaceutical products and development of reliable drug delivery systems.

  15. Benefits of plasma rich in growth factors (PRGF) in skin photodamage: clinical response and histological assessment.

    Science.gov (United States)

    Díaz-Ley, B; Cuevast, J; Alonso-Castro, L; Calvo, M I; Ríos-Buceta, L; Orive, G; Anitua, E; Jaén, P

    2015-01-01

    Skin ageing is characterized by small and fine wrinkles, roughness, laxity, and pigmentation as a result of epidermal thinning, collagen degradation, dermal atrophy, and fewer fibroblasts. Plasma rich in growth factors (PRGF) is an autologous plasma preparation enriched in proteins obtained from patient's own blood aimed at accelerating tissue repair and regeneration. To evaluate the benefits of PRGF in skin photodamage, 10 healthy volunteers were treated with three consecutive intradermal injections of PRGF in the facial area. Clinical outcomes and histological analysis were performed. A statistically significant increase in the epidermis and papillary dermis thickness was seen after PRGF treatment (p PRGF treatment, a reduction of the average area fraction of solar elastosis was observed in patients with clinical and histological signs of skin photodamage (p PRGF use was 0.75 (9/12) for the group of patients with signs of skin photodamage. Intradermal PRGF infiltration appears to be an effective treatment for the photodamaged skin. © 2015 Wiley Periodicals, Inc.

  16. Further Relationships Between Blood Chemical Values and College Student Performance and Attitudes.

    Science.gov (United States)

    Lindeman, Richard H.; And Others

    Blood serum uric acid and cholesterol levels in the blood were studied in relation to inner drive and external pressures of college students in the U.S.A. and in Sweden. Subjects for the study included 210 American and 78 Swedish male and female college students and 138 college football players. The blood chemicals were measured by Technicon…

  17. Isotopic analysis of calcium in blood plasma and bone from mouse samples by multiple collector-ICP-mass spectrometry

    International Nuclear Information System (INIS)

    Hirata, Takafumi; Tanoshima, Mina; Suga, Akinobu; Tanaka, Yu-ki; Nagata, Yuichi; Shinohara, Atsuko; Chiba, Momoko

    2008-01-01

    The biological processing of Ca produces significant stable isotope fractionation. The level of isotopic fractionation can provide key information about the variation in dietary consumption or Ca metabolism. To investigate this, we measured the 43 Ca/ 42 Ca and 44 Ca/ 42 Ca ratios for bone and blood plasma samples collected from mice of various ages using multiple collector-ICP-mass spectrometry (MC-ICP-MS). The 44 Ca/ 42 Ca ratio in bones was significantly (0.44 - 0.84 per mille) lower than the corresponding ratios in the diet, suggesting that Ca was isotopically fractionated during Ca metabolism for bone formation. The resulting 44 Ca/ 42 Ca ratios for blood plasma showed almost identical, or slightly higher, values (0.03 - 0.2 per mille) than found in a corresponding diet. This indicates that a significant amount of Ca in the blood plasma was from dietary sources. Unlike that discovered for Fe, there were not significant differences in the measured 44 Ca/ 42 Ca ratios between female and male specimens (for either bone or blood plasma samples). Similarity, the 44 Ca/ 42 Ca ratios suggests that there were no significant differences in Ca dietary consumption or Ca metabolism between female and male specimens. In contrast, the 44 Ca/ 42 Ca ratios of blood plasma from mother mice during the lactation period were significantly higher than those for all other adult specimens. This suggests that Ca supplied to infants through lactation was isotopically lighter, and the preferential supply of isotropically lighter Ca resulted in isotopically heavier Ca in blood plasma of mother mice during the lactation period. The data obtained here clearly demonstrate that the Ca isotopic ratio has a potential to become a new tool for evaluating changes in dietary consumption, or Ca metabolism of animals. (author)

  18. PIXE elemental analysis of erythrocyte and blood plasma samples from human pregnancies

    International Nuclear Information System (INIS)

    Borbely-Kiss, I.; Koltay, E.; Laszlo, S.; Szabo, Gy.

    1984-01-01

    Elemental concentrations of P, S, Cl, K, Ca, Fe, Ni, Cu, Zn, Br, Rb have been determined in erythrocyte and blood plasma samples from normal and diabetic human pregnancies. Average values, the dependence of the concentrations on the time during gestation period, the correlation coefficients for pairs of elements as well as for the same elements in plasma and erythrocyte samples are given. A marked difference appeared in a number of cases between normal and diabetic pregnancies. (author)

  19. PIXE elemental analysis of erythrocyte and blood plasma samples from human pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Borbely-Kiss, I; Koltay, E; Laszlo, S; Szabo, Gy [Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete; Goedeny, S [Orvostudomanyi Egyetem, Szeged (Hungary). Szueleszeti es Noegyogyaszati Klinika; Seif El-Nasr, S [Teachers' Coll. for Women, Samia (Kuwait)

    1984-07-01

    Elemental concentrations of P, S, Cl, K, Ca, Fe, Ni, Cu, Zn, Br, Rb have been determined in erythrocyte and blood plasma samples from normal and diabetic human pregnancies. Average values, the dependence of the concentrations on the time during gestation period, the correlation coefficients for pairs of elements as well as for the same elements in plasma and erythrocyte samples are given. A marked difference appeared in a number of cases between normal and diabetic pregnancies. 11 refs.

  20. Study on plasma pre-functionalized PVC film grafted with TiO2/PVP to improve blood compatible and antibacterial properties

    International Nuclear Information System (INIS)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Rodríguez, Carmen Serra

    2017-01-01

    Research into the design of new biopolymers/polymer functionalized with nanoparticles is of tremendous interest to the medical sector, particularly with regard to blood-contacting devices. In this present study, a steady blood compatible and active antibacterial coating was fabricated by the grafting of titanium dioxide (TiO 2 )/polyvinylpyyrolidone (PVP) onto a polyvinyl chloride (PVC) film surface via the direct-current glow discharge plasma method. To enhance the chemical interaction between TiO 2 /PVP and PVC, the surfaces of the PVC films were functionalized by different plasmas (air, argon, and oxygen) before coating. In this study, the plasma parameters were varied, such as treatment time of about 5–20 min for a constant power of 100 W, potential 300 V, and a constant gas pressure of 2 Pa for air, argon, and oxygen gas environment. Then, the different plasma treatments on the PVC films, TiO 2 /PVP were grafted using a simple dip-coating method. In addition, the TiO 2 /PVP-grafted PVC films were characterized by contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, field-emission scanning electron microscope, and x-ray photo electron spectroscopy. Importantly, TiO 2 /PVP is grafted onto the PVC surface due to the plasma-based retained functionality and demonstrates adhesive efficiency, which was observed by XPS. The bio-stability of the TiO 2 /PVP-modified PVC film was evaluated by in vitro platelet activation analysis and protein adsorption analysis. Then, the antibacterial properties were evaluated by the agar diffusion method against Escherichia coli . The result reveals that the grafting of TiO 2 /PVP was slightly higher for the 15 min oxygen plasma-functionalized PVC, which significantly decreases the platelet adhesion and protein adsorption. Moreover, the antibacterial properties of the 15 min oxygen plasma-functionalized PVC with TiO 2 /PVP-grafted film is also greatly improved compared with an air- and argon

  1. Plasma brain-derived neurotrophic factor and reverse dipping pattern of nocturnal blood pressure in patients with cardiovascular risk factors.

    Directory of Open Access Journals (Sweden)

    Manabu Kadoya

    Full Text Available Basic studies have shown that brain-derived neurotrophic factor (BDNF has critical roles in the survival, growth, maintenance, and death of central and peripheral neurons, while it is also involved in regulation of the autonomic nervous system. Furthermore, recent clinical studies have suggested potential role of plasma BDNF in the circulatory system.We investigated the mutual relationships among plasma BDNF, patterns of nocturnal blood pressure changes (dippers, non-dippers, extra-dippers, and reverse-dippers, and cardiac autonomic function as determined by heart rate variability (HRV.This was a cross-sectional study of patients registered in the Hyogo Sleep Cardio-Autonomic Atherosclerosis (HSCAA Study from October 2010 to November 2012.Two-hundred fifty patients with 1 or more cardiovascular risk factor(s (obesity, smoking, presence of cardiovascular event history, hypertension, dyslipidemia, diabetes mellitus, chronic kidney disease were enrolled.Plasma BDNF levels (natural logarithm transformed were significantly (p = 0.001 lower in reverse-dipper patients (7.18±0.69 pg/ml, mean ± SD, n = 36 as compared to dippers (7.86±0.86 pg/ml, n = 100. Multiple logistic regression analysis showed that BDNF (odds ratios: 0.417, 95% confidence interval: 0.228-0.762, P = 0.004 was the sole factor significantly and independently associated with the reverse-dippers as compared with dippers. Furthermore, plasma BDNF level was significantly and positively correlated with the time-domain (SDNN, SDANN5, CVRR and frequency-domain (LF of HRV parameters. Finally, multiple logistic regression analyses showed that the relationship between plasma BDNF and the reverse-dippers was weakened, yet remained significant or borderline significant even after adjusting for HRV parameters.Low plasma BDNF was independently associated with patients showing a reverse-dipper pattern of nocturnal blood pressure, in which an imbalance of cardiac autonomic function

  2. Adsorption of viral particles from the blood plasma of patients with viral hepatitis on nanodiamonds.

    Science.gov (United States)

    Baron, A V; Osipov, N V; Yashchenko, S V; Kokotukha, Yu A; Baron, I J; Puzyr, A P; Olkhovskiy, I A; Bondar, V S

    2016-07-01

    Adsorption of viral particles from the blood plasma of patients with viral hepatitis B and C on modified nanodiamonds (MNDs) was shown in the in vitro experiments. PCR method showed the treatment of plasma with MNDs leads to a decrease in the viral load by 2-3 orders of magnitude or more in both cases studied. These results make it possible to predict the applicability of MNDs for the development of new technologies of hemodialysis and plasmapheresis for binding and removal of viral particles from the blood of infected patients.

  3. Quasi-equilibria and plasma chemical similarity in non-isothermal reactive plasmas

    International Nuclear Information System (INIS)

    Miethke, F.; Rutscher, A.; Wagner, H.E.

    2000-01-01

    With regard to the output of stable products the mode of operation of non-isothermal plasma chemical reactors shows physical and chemical well defined states, which represent limiting cases and may be interpreted as quasi-equilibrium states. The occurrence and the characteristics of these states, meanwhile more than once observed and described, are demonstrated by an instructive model reaction. Within the frame of the so-called Macroscopic Kinetics a central parameter is dominating the reactor operation. This result may be generalized and is linked up to the application of similarity principles for the reactor operation. After the general formulation of such principles, starting from the balance equations of particles and energy, a dimensionless similarity parameter is formulated, characterizing the composition of the effluent gas of the reactor. The applicability of this parameter is demonstrated by experimental examples. (Authors)

  4. Relationship between gestational fasting plasma glucose and neonatal birth weight, prenatal blood pressure and dystocia in pregnant Chinese women.

    Science.gov (United States)

    Zhu, Min; Cai, Jing; Liu, Shujuan; Huang, Mingwei; Chen, Yao; Lai, Xiaolan; Chen, Yuyu; Zhao, Zhongwen; Wu, Fangzhen; Wu, Dongmei; Miu, Haiyan; Lai, Shenghan; Chen, Gang

    2014-09-01

    Little is known about the optimal cut-off point of fasting plasma glucose for the diagnosis of gestational diabetes mellitus for pregnant Chinese women. This study investigates the relationship between gestational fasting plasma glucose and several variables: neonatal birth weight, prenatal blood pressure and dystocia rate of pregnant women. In this study, we hoped to provide a useful tool to screen gestational diabetes mellitus in pregnant Chinese women. For 1058 pregnant women enrolled in our hospital at pregnancy weeks 22-30, fasting plasma glucose, neonatal birth weight and prenatal blood pressure, as well as dystocia conditions, were examined. We analysed the correlations between the following: gestational fasting plasma glucose and neonatal birth weight; prenatal blood pressure and gestational fasting plasma glucose as well as dystocia rate and gestational fasting plasma glucose group. A modest correlation was observed between gestational fasting plasma glucose and neonatal birth weight (r = 0.093, p = 0.003). The macrosomia rate was smallest when the gestational fasting plasma glucose was in the range 3.51-5.5 mmol/L. Prenatal blood pressure increased linearly with increasing gestational fasting plasma glucose (p = 0.000). There was a significant difference between the dystocia rates in different fasting plasma glucose groups (chi-squared = 13.015, p = 0.043). The results showed that the dystocia rate significantly increased when gestational fasting plasma glucose was >4.9 mmol/L; p = 0.03, OR = 2.156 (95% CI, 1.077-4.318). We suggest that the optimal range of gestational fasting plasma glucose for pregnant Chinese women is in the range 3.5-4.9 mmol/L. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Plasma flame for mass purification of contaminated air with chemical and biological warfare agents

    International Nuclear Information System (INIS)

    Uhm, Han S.; Shin, Dong H.; Hong, Yong C.

    2006-01-01

    An elimination of airborne simulated chemical and biological warfare agents was carried out by making use of a plasma flame made of atmospheric plasma and a fuel-burning flame, which can purify the interior air of a large volume in isolated spaces such as buildings, public transportation systems, and military vehicles. The plasma flame generator consists of a microwave plasma torch connected in series to a fuel injector and a reaction chamber. For example, a reaction chamber, with the dimensions of a 22 cm diameter and 30 cm length, purifies an airflow rate of 5000 lpm contaminated with toluene (the simulated chemical agent) and soot from a diesel engine (the simulated aerosol for biological agents). Large volumes of purification by the plasma flame will free mankind from the threat of airborne warfare agents. The plasma flame may also effectively purify air that is contaminated with volatile organic compounds, in addition to eliminating soot from diesel engines as an environmental application

  6. Fresenius AS.TEC204 blood cell separator.

    Science.gov (United States)

    Sugai, Mikiya

    2003-02-01

    Fresenius AS.TEC204 is a third-generation blood cell separator that incorporates the continuous centrifugal separation method and automatic control of the cell separation process. Continuous centrifugation separates cell components according to their specific gravity, and different cell components are either harvested or eliminated as needed. The interface between the red blood cell and plasma is optically detected, and the Interface Control (IFC) cooperates with different pumps, monitors and detectors to harvest required components automatically. The system is composed of three major sections; the Front Panel Unit; the Pump Unit, and the Centrifuge Unit. This unit can be used for a wide variety of clinical applications including collection of platelets, peripheral blood stem cells, bone marrow stem cells, granulocytes, mononuclear cells, and exchange of plasma or red cells, and for plasma treatment.

  7. Diffusion in plasma: The Hall effect, compositional waves, and chemical spots

    Energy Technology Data Exchange (ETDEWEB)

    Urpin, V., E-mail: Vadim.urpin@uv.es [Ioffe Institute of Physics and Technology (Russian Federation)

    2017-03-15

    Diffusion caused by a combined influence of the electric current and Hall effect is considered, and it is argued that such diffusion can form inhomogeneities of a chemical composition in plasma. The considered mechanism can be responsible for the formation of element spots in laboratory and astrophysical plasmas. This current-driven diffusion can be accompanied by propagation of a particular type of waves in which the impurity number density oscillates alone. These compositional waves exist if the magnetic pressure in plasma is much greater than the gas pressure.

  8. Surface chemical changes of atmospheric pressure plasma treated rabbit fibres important for felting process

    Energy Technology Data Exchange (ETDEWEB)

    Štěpánová, Vlasta, E-mail: vstepanova@mail.muni.cz [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Slavíček, Pavel; Stupavská, Monika; Jurmanová, Jana [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Černák, Mirko [Department of Physical Electronics, Faculty of Science Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Department of Experimental Physics, Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2015-11-15

    Graphical abstract: - Highlights: • Rabbit fibres plasma treatment is an effective method for fibres modification. • Atmospheric pressure plasma treatment is able to affect fibres properties. • Surface changes on fibres after plasma treatment were analysed via SEM, ATR-FTIR, XPS. • Significant increase of fibres wettability after plasma treatment was observed. • Plasma treatment at atmospheric pressure can replace the chemical treatment of fibres. - Abstract: We introduce the atmospheric pressure plasma treatment as a suitable procedure for in-line industrial application of rabbit fibres pre-treatment. Changes of rabbit fibre properties due to the plasma treatment were studied in order to develop new technology of plasma-based treatment before felting. Diffuse Coplanar Surface Barrier Discharge (DCSBD) in ambient air at atmospheric pressure was used for plasma treatment. Scanning electron microscopy was used for determination of the fibres morphology before and after plasma treatment. X-ray photoelectron spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy were used for evaluation of reactive groups. The concentration of carbon decreased and conversely the concentration of nitrogen and oxygen increased after plasma treatment. Aging effect of plasma treated fibres was also investigated. Using Washburn method the significant increase of fibres wettability was observed after plasma treatment. New approach of pre-treatment of fibres before felting using plasma was developed. Plasma treatment of fibres at atmospheric pressure can replace the chemical method which consists of application of strong acids on fibres.

  9. Plasma effects in aligned carbon nanoflake growth by plasma-enhanced hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B.B. [College of Chemistry and Chemical Engineering, Chongqing University of Technology, 69 Hongguang Rd, Lijiatuo, Banan District, Chongqing 400054 (China); Zheng, K. [Institute of Microstructure and Properties of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Cheng, Q.J., E-mail: qijin.cheng@xmu.edu.cn [School of Energy Research, Xiamen University, Xiamen 361005 (China); Ostrikov, K. [Plasma Nanoscience Center Australia (PNCA), Manufacturing Flagship, Commonwealth Scientific and Industrial Research Organization, PO Box 218, Lindfield 2070, NSW (Australia); Institute for Future Environments and School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane 4000, QLD (Australia); Plasma Nanoscience, School of Physics, The University of Sydney, Sydney 2006, NSW (Australia)

    2015-01-15

    Highlights: • Plasma-specific effects in the growth of carbon nanoflakes (CNFs) are studied. • Electic field in the plasma sheath promotes separation of CNFs from the substrate. • The orentention of GNFs is related to the combined electic force and growth effects. • The high growth grates of aligned GNFs are plasma-related. - Abstract: Carbon nanofilms are directly grown on silicon substrates by plasma-enhanced hot filament chemical vapor deposition in methane environment. It is shown that the nanofilms are composed of aligned carbon nanoflakes by extensive investigation of experimental results of field emission scanning electron microscopy, micro-Raman spectroscopy and transmission electron microscopy. In comparison with the graphene-like films grown without plasmas, the carbon nanoflakes grow in an alignment mode and the growth rate of the films is increased. The effects of the plasma on the growth of the carbon nanofilms are studied. The plasma plays three main effects of (1) promoting the separation of the carbon nanoflakes from the silicon substrate, (2) accelerating the motion of hydrocarbon radicals, and (3) enhancing the deposition of hydrocarbon ions onto the substrate surface. Due to these plasma-specific effects, the carbon nanofilms can be formed from the aligned carbon nanoflakes with a high rate. These results advance our knowledge on the synthesis, properties and applications of graphene-based materials.

  10. Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.

    Science.gov (United States)

    Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Erdem Alaca, B; Kavakli, Ibrahim Halil; Urey, Hakan

    2013-10-01

    This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. Copyright © 2013. Published by Elsevier Inc.

  11. Treatment goals for ambulatory blood pressure and plasma lipids after stroke are often not reached

    DEFF Research Database (Denmark)

    Engberg, Aase Worså; Kofoed, Klaus

    2013-01-01

    In Danish health care, secondary prevention after stroke is currently handled mainly by general practitioners using office blood pressure (OBP) assessment of hypertension. The aim of this study was to compare the OBP approach to 24-hour assessment by ambulatory blood pressure (ABP) monitoring....... Furthermore, we aimed to record the degree of adherence to recommended therapy goals for blood pressure and plasma lipids....

  12. Alkaline and Acid Phosphatase Activity in Blood Plasma of Chickens Irradiated by Low dose Gamma Radiation

    International Nuclear Information System (INIS)

    Petar, K.; Marinko, V.; Saveta, M.; Miljenko, S.

    2004-01-01

    In our previous paper (Kraljevic et, al, 2000; Kraljevic et al 2002) we showed that the growth of the chickens hatched from eggs irradiated with 0.15 Gy gamma-rays before incubation was significantly higher than in controls during the fattening period (1-42 days). The concentration of total protein, glucose and cholesterol in the blood plasma of the same chickens was also significantly changed. In this paper an attempt was made to determine the effect of irradiation of eggs by low dose ionizing radiation before incubation upon activity of alkaline and acid phosphatase in the blood plasma of chickens hatched from irradiated eggs. The eggs of heavy breeding chickens were irradiated by dose of 0.15 Gy gamma radiation (60 Co) before incubation. Along with the chickens which were hatched from irradiated eggs, there was a control group of chickens hatched from nonirradiated eggs. All other conditions were the same for both groups. After hatching, blood samples were taken from the wing vein on days 1, 3, 5, 6, 10, 20, 30 and 42. The activity of both enzymes was determined spectrophotometrically by using Boehring Mannheim GmbH optimized kits. the activity of alkaline phosphatase in blood plasma was decreased on days 42, and the activity of acid phosphatase in the blood plasma of the same chickens was increased on day 42. Obtained results confirm our early obtained results that low dose of gamma radiation has effects upon metabolic processes in the chickens hatched from eggs irradiated before incubation. (Author)

  13. Nifedipine effect on the labelling of blood cells and plasma proteins with Tc-99m

    International Nuclear Information System (INIS)

    Gutfilen, B.; Boasquevisque, E.M.; Bernardo Filho, M.

    1988-01-01

    The labeling of red blood cells (RBC) with Tc-99m depends on the presence of stannous ion (Sn) that helps this radionuclide's fixation on the hemoglobin molecule. Nifedipine is an agent capable to block a specific way where calcius (Ca) ion acrosses the cellular membrane and to bind itself on plasma proteins. The effect of nifedipine in the labeling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca and Sn ions. Blood with anticoagulant was treated with nifedipine concentration of 10 -6 M for 15 min at 37 0 C. The labeling of RBC with Tc-99m was done incubating with Sn ion solution (3 uM) for different times. The % of radioactivity in RBC was determined. Samples of plasma were precipited with trichloroacetic acid and the % of radiocctivity in insoluble fraction was calculated. The same procedure was done using different nifedipine concentrations and the blood was incubated for 60 min with Sn ion. The determination of the % of Tc-99m labeled in RBC and plasma proteins showed that this drug does not have the capability to alter this incorporation because the results are similar to control. It is suggested that the Sn ions passage across RBC is not altered by nifedipine although this drug could bind to plasma protein, it does not modify the Tc-99m fixation on it. (author) [pt

  14. Modification of optical and electrical properties of chemical bath deposited CdS using plasma treatments

    International Nuclear Information System (INIS)

    Gonzalez, G.; Krishnan, B.; Avellaneda, D.; Castillo, G. Alan; Das Roy, T.K.; Shaji, S.

    2011-01-01

    Cadmium sulphide (CdS) is a well known n-type semiconductor that is widely used in solar cells. Here we report preparation and characterization of chemical bath deposited CdS thin films and modification of their optical and electrical properties using plasma treatments. CdS thin films were prepared from a chemical bath containing Cadmium chloride, Triethanolamine and Thiourea under various deposition conditions. Good quality thin films were obtained during deposition times of 5, 10 and 15 min. CdS thin films prepared for 10 min. were treated using a glow discharge plasma having nitrogen and argon carrier gases. The changes in morphology, optical and electrical properties of these plasma treated CdS thin films were analyzed in detail. The results obtained show that plasma treatment is an effective technique in modification of the optical and electrical properties of chemical bath deposited CdS thin films.

  15. Modification of optical and electrical properties of chemical bath deposited CdS using plasma treatments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, G. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); Krishnan, B. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); CIIDIT, Universidad Autonoma de Nuevo Leon, Apodaca, Nuevo Leon (Mexico); Avellaneda, D.; Castillo, G. Alan; Das Roy, T.K. [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); Shaji, S., E-mail: sshajis@yahoo.com [Facultad de Ingenieria Mecanica y Electrica, Universidad Autonoma de Nuevo Leon, San Nicolas de los Garza, Nuevo Leon, C.P 66450 (Mexico); CIIDIT, Universidad Autonoma de Nuevo Leon, Apodaca, Nuevo Leon (Mexico)

    2011-08-31

    Cadmium sulphide (CdS) is a well known n-type semiconductor that is widely used in solar cells. Here we report preparation and characterization of chemical bath deposited CdS thin films and modification of their optical and electrical properties using plasma treatments. CdS thin films were prepared from a chemical bath containing Cadmium chloride, Triethanolamine and Thiourea under various deposition conditions. Good quality thin films were obtained during deposition times of 5, 10 and 15 min. CdS thin films prepared for 10 min. were treated using a glow discharge plasma having nitrogen and argon carrier gases. The changes in morphology, optical and electrical properties of these plasma treated CdS thin films were analyzed in detail. The results obtained show that plasma treatment is an effective technique in modification of the optical and electrical properties of chemical bath deposited CdS thin films.

  16. Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding

    International Nuclear Information System (INIS)

    Kuo, S P; Chen, C Y; Fan, H W; Tarasenko, O; Scott, A; Lahiani, M; Alusta, P; Chang, J; Popovic, S; Drake, J D; Nikolic, M

    2009-01-01

    The effectiveness and mechanism of a low temperature air plasma torch in clotting blood are explored. Both blood droplets and smeared blood samples were used in the tests. The treated droplet samples reveal how blood clotting depends on the distance at which the torch operated, and for how long the droplets have been exposed to the torch. Microscopy and cell count of smeared blood samples shed light on dependencies of erythrocyte and platelet counts on torch distance and exposure time. With an increase of torch distance, the platelet count of treated blood samples increases but is less than that of the control. The flux of reactive atomic oxygen (RAO) and the degree of blood clotting decreased. With an increase of exposure time, platelet count of treated samples decreased, while the degree of clot increased. The correlation among these dependencies and published data support a blood clotting mechanism that RAO as well as other likely reactive oxygen species generated by the plasma torch activate erythrocyte-platelets interactions and induces blood coagulation.

  17. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    using a biosensitive electrode (Exp. 1) or a standard colourimetric method (Exp. 2). In general, glucose measured in whole blood was 7-11% lower than in plasma at low glucose levels (3.5-5 mM), whereas the methods agreed well at high glucose levels (10-14 mM). Evaluation of the regression lines between......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  18. Plasma-enhanced chemical vapor deposition of aluminum oxide using ultrashort precursor injection pulses

    NARCIS (Netherlands)

    Dingemans, G.; Sanden, van de M.C.M.; Kessels, W.M.M.

    2012-01-01

    An alternative plasma-enhanced chemical vapor deposition (PECVD) method is developed and applied for the deposition of high-quality aluminum oxide (AlOx) films. The PECVD method combines a continuous plasma with ultrashort precursor injection pulses. We demonstrate that the modulation of the

  19. Increasing fetal ovine number per gestation alters fetal plasma clinical chemistry values.

    Science.gov (United States)

    Zywicki, Micaela; Blohowiak, Sharon E; Magness, Ronald R; Segar, Jeffrey L; Kling, Pamela J

    2016-08-01

    Intrauterine growth restriction (IUGR) is interconnected with developmental programming of lifelong pathophysiology. IUGR is seen in human multifetal pregnancies, with stepwise rises in fetal numbers interfering with placental nutrient delivery. It remains unknown whether fetal blood analyses would reflect fetal nutrition, liver, and excretory function in the last trimester of human or ovine IUGR In an ovine model, we hypothesized that fetal plasma biochemical values would reflect progressive placental, fetal liver, and fetal kidney dysfunction as the number of fetuses per gestation rose. To determine fetal plasma biochemical values in singleton, twin, triplet, and quadruplet/quintuplet ovine gestation, we investigated morphometric measures and comprehensive metabolic panels with nutritional measures, liver enzymes, and placental and fetal kidney excretory measures at gestational day (GD) 130 (90% gestation). As anticipated, placental dysfunction was supported by a stepwise fall in fetal weight, fetal plasma glucose, and triglyceride levels as fetal number per ewe rose. Fetal glucose and triglycerides were directly related to fetal weight. Plasma creatinine, reflecting fetal renal excretory function, and plasma cholesterol, reflecting placental excretory function, were inversely correlated with fetal weight. Progressive biochemical disturbances and growth restriction accompanied the rise in fetal number. Understanding the compensatory and adaptive responses of growth-restricted fetuses at the biochemical level may help explain how metabolic pathways in growth restriction can be predetermined at birth. This physiological understanding is important for clinical care and generating interventional strategies to prevent altered developmental programming in multifetal gestation. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  20. Influence of non-thermal plasma forming gases on improvement of surface properties of low density polyethylene (LDPE)

    Energy Technology Data Exchange (ETDEWEB)

    Pandiyaraj, K. Navaneetha, E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Ruzybayev, Inci; Shah, S. Ismat [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark, NJ (United States); Su, Pi-Guey [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Halleluyah, Jr. mercy; Halim, Ahmad Sukari [School of Medical Sciences, Health Campus Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2014-07-01

    Owing to the superior physico-chemical properties, the low density polyethylene (LDPE) has been widely used in the various industrial applications; especially in biomedical field for artificial organs, medical devices and disposable clinical apparatus. However, the poor anticoagulation property is one of the main drawbacks of the LDPE due to its poor surface properties. Therefore, in this paper we present the effect of plasma forming gases such as argon (Ar), oxygen (O{sub 2}), air and argon-oxygen (Ar + O{sub 2}) mixture on improvement of the surfaces properties of LDPE film using direct current (dc) excited glow discharge plasma. Contact angle with evaluation of surface energy, X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM) techniques were used to examine the change in surface properties such as hydrophilicity, chemical composition and surface topography, respectively. Furthermore, the hydrophobic recovery of the plasma treated LDPE was analyzed using ageing effect under different storage condition i.e. in air and water. The adhesive strength of the LDPE films was determined using T-peel test. In vitro tests were used to examine the blood compatibility of the surface modified LDPE films. It has been found that the hydrophilicity of the various plasma treated LDPE films was improved significantly due to the formation of oxygen containing polar groups such as OH, COO, C-O, C=O as confirmed by contact angle and XPS analysis. AFM revealed the changes in surface topography of plasma processed films. The gas mixture Ar + O{sub 2} plasma influenced the remarkable improvement on the surface properties of a LDPE film compared with other gaseous plasmas. These physiochemical changes induced by the plasma on the surface facilitate to improve the adhesive strength and blood compatibility.

  1. Influence of non-thermal plasma forming gases on improvement of surface properties of low density polyethylene (LDPE)

    International Nuclear Information System (INIS)

    Pandiyaraj, K. Navaneetha; Deshmukh, R.R.; Ruzybayev, Inci; Shah, S. Ismat; Su, Pi-Guey; Halleluyah, Jr. mercy; Halim, Ahmad Sukari

    2014-01-01

    Owing to the superior physico-chemical properties, the low density polyethylene (LDPE) has been widely used in the various industrial applications; especially in biomedical field for artificial organs, medical devices and disposable clinical apparatus. However, the poor anticoagulation property is one of the main drawbacks of the LDPE due to its poor surface properties. Therefore, in this paper we present the effect of plasma forming gases such as argon (Ar), oxygen (O 2 ), air and argon-oxygen (Ar + O 2 ) mixture on improvement of the surfaces properties of LDPE film using direct current (dc) excited glow discharge plasma. Contact angle with evaluation of surface energy, X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM) techniques were used to examine the change in surface properties such as hydrophilicity, chemical composition and surface topography, respectively. Furthermore, the hydrophobic recovery of the plasma treated LDPE was analyzed using ageing effect under different storage condition i.e. in air and water. The adhesive strength of the LDPE films was determined using T-peel test. In vitro tests were used to examine the blood compatibility of the surface modified LDPE films. It has been found that the hydrophilicity of the various plasma treated LDPE films was improved significantly due to the formation of oxygen containing polar groups such as OH, COO, C-O, C=O as confirmed by contact angle and XPS analysis. AFM revealed the changes in surface topography of plasma processed films. The gas mixture Ar + O 2 plasma influenced the remarkable improvement on the surface properties of a LDPE film compared with other gaseous plasmas. These physiochemical changes induced by the plasma on the surface facilitate to improve the adhesive strength and blood compatibility.

  2. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    Science.gov (United States)

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of 4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  3. Abnormalities in plasma and red blood cell fatty acid profiles of patients with colorectal cancer.

    OpenAIRE

    Bar??, L.; Hermoso, J. C.; N????ez, M. C.; Jim??nez-Rios, J. A.; Gil, A.

    1998-01-01

    We evaluated total plasma fatty acid concentrations and percentages, and the fatty acid profiles for the different plasma lipid fractions and red blood cell lipids, in 17 patients with untreated colorectal cancer and 12 age-matched controls with no malignant diseases, from the same geographical area. Cancer patients had significantly lower total plasma concentrations of saturated, monounsaturated and essential fatty acids and their polyunsaturated derivatives than healthy controls; when the v...

  4. Plasma cell leukemia

    DEFF Research Database (Denmark)

    Fernández de Larrea, C; Kyle, R A; Durie, B G M

    2013-01-01

    Plasma cell leukemia (PCL) is a rare and aggressive variant of myeloma characterized by the presence of circulating plasma cells. It is classified as either primary PCL occurring at diagnosis or as secondary PCL in patients with relapsed/refractory myeloma. Primary PCL is a distinct clinic......-pathological entity with different cytogenetic and molecular findings. The clinical course is aggressive with short remissions and survival duration. The diagnosis is based upon the percentage (≥ 20%) and absolute number (≥ 2 × 10(9)/l) of plasma cells in the peripheral blood. It is proposed that the thresholds...... regimens and bortezomib-based regimens are recommended followed by high-dose therapy with autologous stem cell transplantation if feasible. Allogeneic transplantation can be considered in younger patients. Prospective multicenter studies are required to provide revised definitions and better understanding...

  5. Self-monitored blood pressure: a role in clinical practice?

    Science.gov (United States)

    Padfield, Paul L

    2002-02-01

    Electronic self-monitoring of blood pressure is increasing in popularity and most international guidelines on the management of hypertension approve cautious use of the technique in the assessment of potentially hypertensive individuals. A recent editorial in the Archives of Internal Medicine suggested that it was "appropriate to encourage the widespread use of self recorded BP as an important adjunct to the clinical care of the patient with hypertension". Such a statement is based on increasing evidence that self-monitoring of blood pressure gives similar information to daytime ambulatory blood pressure -- a now well-established technology in the management of hypertension. Suggested strategies for the use of self-monitoring of blood pressure include monitoring in individuals whose clinical risk status is low enough that they need not necessarily be given medical therapy simply on the basis of a clinic pressure (i.e. at a 10 year risk of cardiovascular disease below 20%). The threshold for defining 'normotension/hypertension' is now regarded as being broadly similar for ABPM and SBPM and is set at 135/85 mmHg. In a recent meta-analysis of all available studies the average difference between these techniques, using the same patients, is -1.7/1.2 mmHg. There is some evidence that careful use of self-monitoring may improve blood pressure control in patients who are otherwise resistant to care. Self-monitoring of blood pressure has now been shown in at least one major prospective study to predict outcome better than clinic pressures and in that setting it now has equivalence to the use of ABPM. There remain issues regarding the availability of validated devices, the quality of training of patients in their use and the possibility that inaccurate recording might occur, either deliberately or by accident. Self-monitoring of blood pressure may well not give the same readings as carefully measured blood pressure by research nurses but its use is clearly superior to

  6. Bovine plasma protein fractionation by ion exchange chromatography.

    Science.gov (United States)

    Moure, F; Rendueles, M; Díaz, M

    2004-12-01

    An ion exchange chromatography process was developed to separate the main protein fractions of bovine blood plasma using a composite material, Q-HyperD resin, and a gel material, DEAE-Sepharose. The experiments were carried out at semipreparative scale. It was necessary to establish analytical methods of electrophoresis and HPLC to identify the fractionated proteins. Results show that these materials are able to adequately fractionate different protein groups from the raw blood plasma. This method may be used to avoid chemical fractionation using agents such as ethanol or PEG and, thus, decrease protein denaturation of the different fractions to be used for research or pharmaceutical purposes. The Q-HyperD resin presents a better retention capacity for plasma protein than DEAE-Sepharose under the experimental conditions employed.

  7. Alternative Blood Products and Clinical Needs in Transfusion Medicine

    OpenAIRE

    Whitsett, Carolyn; Vaglio, Stefania; Grazzini, Giuliano

    2012-01-01

    The primary focus of national blood programs is the provision of a safe and adequate blood supply. This goal is dependent on regular voluntary donations and a regulatory infrastructure that establishes and enforces standards for blood safety. Progress in ex vivo expansion of blood cells from cell sources including peripheral blood, cord blood, induced pluripotent stem cells, and human embryonic stem cell lines will likely make alternative transfusion products available for clinical use in the...

  8. Molecular typing for blood group antigens within 40 min by direct polymerase chain reaction from plasma or serum.

    Science.gov (United States)

    Wagner, Franz F; Flegel, Willy A; Bittner, Rita; Döscher, Andrea

    2017-03-01

    Determining blood group antigens by serological methods may be unreliable in certain situations, such as in patients after chronic or massive transfusion. Red cell genotyping offers a complementary approach, but current methods may take much longer than conventional serological typing, limiting their utility in urgent situations. To narrow this gap, we devised a rapid method using direct polymerase chain reaction (PCR) amplification while avoiding the DNA extraction step. DNA was amplified by PCR directly from plasma or serum of blood donors followed by a melting curve analysis in a capillary rapid-cycle PCR assay. We evaluated the single nucleotide polymorphisms underlying the clinically relevant Fy a , Fy b , Jk a and Jk b antigens, with our analysis being completed within 40 min of receiving a plasma or serum sample. The positive predictive value was 100% and the negative predictive value at least 84%. Direct PCR with melting point analysis allowed faster red cell genotyping to predict blood group antigens than any previous molecular method. Our assay may be used as a screening tool with subsequent confirmatory testing, within the limitations of the false-negative rate. With fast turnaround times, the rapid-cycle PCR assay may eventually be developed and applied to red cell genotyping in the hospital setting. © 2016 John Wiley & Sons Ltd.

  9. Preparing Platelet-Rich Plasma with Whole Blood Harvested Intraoperatively During Spinal Fusion.

    Science.gov (United States)

    Shen, Bin; Zhang, Zheng; Zhou, Ning-Feng; Huang, Yu-Feng; Bao, Yu-Jie; Wu, De-Sheng; Zhang, Ya-Dong

    2017-07-22

    BACKGROUND Platelet-rich plasma (PRP) has gained growing popularity in use in spinal fusion procedures in the last decade. Substantial intraoperative blood loss is frequently accompanied with spinal fusion, and it is unknown whether blood harvested intraoperatively qualifies for PRP preparation. MATERIAL AND METHODS Whole blood was harvested intraoperatively and venous blood was collected by venipuncture. Then, we investigated the platelet concentrations in whole blood and PRP, the concentration of growth factors in PRP, and the effects of PRP on the proliferation and viability of human bone marrow-derived mesenchymal stem cells (HBMSCs). RESULTS Our results revealed that intraoperatively harvested whole blood and whole blood collected by venipuncture were similar in platelet concentration. In addition, PRP formulations prepared from both kinds of whole blood were similar in concentration of platelet and growth factors. Additional analysis showed that the similar concentrations of growth factors resulted from the similar platelet concentrations of whole blood and PRP between the two groups. Moreover, these two kinds of PRP formulations had similar effects on promoting cell proliferation and enhancing cell viability. CONCLUSIONS Therefore, intraoperatively harvested whole blood may be a potential option for preparing PRP spinal fusion.

  10. Alpha-synuclein levels in blood plasma decline with healthy aging.

    Science.gov (United States)

    Koehler, Niklas K U; Stransky, Elke; Meyer, Mirjam; Gaertner, Susanne; Shing, Mona; Schnaidt, Martina; Celej, Maria S; Jovin, Thomas M; Leyhe, Thomas; Laske, Christoph; Batra, Anil; Buchkremer, Gerhard; Fallgatter, Andreas J; Wernet, Dorothee; Richartz-Salzburger, Elke

    2015-01-01

    There is unequivocal evidence that alpha-synuclein plays a pivotal pathophysiological role in neurodegenerative diseases, and in particular in synucleinopathies. These disorders present with a variable extent of cognitive impairment and alpha-synuclein is being explored as a biomarker in CSF, blood serum and plasma. Considering key events of aging that include proteostasis, alpha-synuclein may not only be useful as a marker for differential diagnosis but also for aging per se. To explore this hypothesis, we developed a highly specific ELISA to measure alpha-synuclein. In healthy males plasma alpha-synuclein levels correlated strongly with age, revealing much lower concentrations in older (avg. 58.1 years) compared to younger (avg. 27.6 years) individuals. This difference between the age groups was enhanced after acidification of the plasmas (phealthy aging. Thus, alpha-synuclein may be a novel biomarker of aging, a factor that should be considered when analyzing its presence in biological specimens.

  11. Clinical Use and Patentability of Cord Blood

    Science.gov (United States)

    Cavusoglu, Turker; Kilic, Kubilay Dogan; Yigitturk, Gurkan; Tomruk, Canberk; Turgut, Mehmet; Uyanikgil, Yigit

    2018-03-14

    The blood in the umbilical cord that provides the connection between mother and fetus during pregnancy is called cord blood. The blood of umbilical cord which is usually got rid of following birth, is a very rich stem cell source. Cord blood collection gives no harm to the mother and baby. Besides, its allogeneic and au-tologous usage, the most important disadvantage is that the number of cells is insufficient in adults. Today, it is predominantly used for therapeutic purposes for many diseases. The aim of this review is giving a detailed information about groups of stem cells in cord blood and determining the point of clinical use. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Wright, Nancy; Deeb, Larry C

    2017-12-23

    To determine patterns of blood glucose monitoring in children and adolescents with type 1 diabetes (T1D) before and after routine T1D clinic visits. Blood glucose monitoring data were downloaded at four consecutive routine clinic visits from children and adolescents aged 5-18 years. Linear mixed models were used to analyze patterns of blood glucose monitoring in patients who had at least 28 days of data stored in their blood glucose monitors. In general, the frequency of blood glucose monitoring decreased across visits, and younger children engaged in more frequent blood glucose monitoring. Blood glucose monitoring increased before the T1D clinic visits in younger children, but not in adolescents. It declined after the visit regardless of age. Members of the T1D care team need to consider that a T1D clinic visit may prompt an increase in blood glucose monitoring when making treatment changes and recommendations. Tailored interventions are needed to maintain that higher level of adherence across time. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  13. A multidisciplinary "think tank": the top 10 clinical trial opportunities in transfusion medicine from the National Heart, Lung, and Blood Institute-sponsored 2009 state-of-the-science symposium.

    Science.gov (United States)

    Josephson, Cassandra D; Glynn, Simone A; Kleinman, Steve H; Blajchman, Morris A

    2011-04-01

    In September 2009, the National Heart, Lung, and Blood Institute convened the State-of-the-Science Symposium in Transfusion Medicine to identify Phase II and/or III clinical trials that would provide important information to advance transfusion medicine. Seven multidisciplinary subcommittees developed proposals in the following areas: 1) platelet (PLT) product use, 2) neonatal and/or pediatric transfusion practice, 3) surgical transfusion practice, 4) intensive care unit and/or in trauma transfusion practice, 5) plasma and/or cryoprecipitate product use and therapeutic apheresis practice, 6) red blood cell (RBC) product use and/or blood conservation management, and 7) medical transfusion practice or blood donor studies. The committees consisted of transfusion medicine specialists, hematologists, cardiovascular surgeons, anesthesiologists, neonatologists, critical care physicians, and clinical trial methodologists. Proposals were presented and an external panel evaluated and prioritized each concept for scientific merit, clinical importance, and feasibility. Twenty-four concepts were presented by the subcommittees. Ten concepts addressed four areas deemed most important: 1) PLT transfusion strategies to prevent and/or mitigate bleeding in neonates and patients with hematologic malignancies, 2) RBC transfusion trigger strategies to improve overall outcomes in different patient populations, 3) evaluation of optimal plasma:PLT:RBC ratios in trauma resuscitation, and 4) pathogen inactivation of PLTs to improve PLT transfusion safety. The proposal themes not only represent inquiries about the indications for transfusion, but also epitomize the lack of consensus when clinical practice lacks a strong evidence base. Ultimately, the purpose of this publication is to provide a "blueprint" of ideas for further development rather than endorse any one specific clinical trial design. © 2010 American Association of Blood Banks.

  14. Study on changes of the plasma cytokines in 60Co γ-ray irradiated blood and leukocyte reduction of whole blood

    International Nuclear Information System (INIS)

    Li Zhiqiang; Le Jiayi; Qu Yihua; Xu Wenhao

    2006-01-01

    Objective: To study the changes of IL-2, IL-6, IFN-γ and TNF-α in 60 Co γ-ray irradiated and leukocyte reduction of whole blood, and to understand the fever phenomenon in patients received blood transfusion. Methods: ELISA method was used to measure changes of the cytokines. Results: The plasma levels of IL-2, IL-6, IFN-γ and TNF-α did not change significantly with extending the conservation period both in 60 Co-irradiated and leukocyte reduction of whole blood. The frequency of fever decreaed obviously with transfusion of 60 Co-irradiated and leukocyte reduction of whole blood. Conclusion: 60 Co-irradiated blood can not only prevent transfusion associated graft-versus-host disease (TA-GVHD), but also decrease non-hemolytic febrile transfusion reactions (NHFTR) effectively. (authors)

  15. The reference range of serum, plasma and erythrocyte magnesium

    Directory of Open Access Journals (Sweden)

    Suzanna Immanuel

    2006-12-01

    Full Text Available The interest in the clinical importance of serum magnesium level has just recently begun with the analysis and findings of abnormal magnesium level in cardiovascular, metabolic and neuromuscular disorder. Although the serum level does not reflect the body magnesium level, but currently, only serum magnesium determination is widely used. Erythrocyte magnesium is considered more sensitive than serum magnesium as it reflects intracellular magnesium status. According to NCCLS (National Committee for Clinical Laboratory Standards every laboratory is recommended to have its own reference range for the tests it performs, including magnesium determination. The reference range obtained is appropriate for the population and affected by the method and technique. This study aimed to find the reference range of serum and plasma magnesium and also intracellular magnesium i.e. erythrocyte magnesium by direct method, and compare the results of serum and plasma magnesium. Blood was taken from 114-blood donor from Unit Transfusi Darah Daerah (UTDD Budhyarto Palang Merah Indonesia (PMI DKI Jakarta, consisted of 57 male and 57 female, aged 17 – 65 years, clinically healthy according to PMI donor criteria. Blood was taken from blood set, collected into 4 ml vacuum tube without anticoagulant for serum magnesium determination and 3 ml vacuum tube with lithium heparin for determination of erythrocyte and plasma magnesium Determination of magnesium level was performed with clinical chemistry auto analyzer Hitachi 912 by Xylidil Blue method colorimetrically. This study showed no significant difference between serum and heparinized plasma extra cellular magnesium. The reference range for serum or plasma magnesium was 1.30 – 2.00 mEq/L and for erythrocyte magnesium was 4.46 - 7.10 mEq/L. (Med J Indones 2006; 15:229-35Keywords: Reference range, extracellular magnesium, intracellular magnesium

  16. Relationship of zinc concentrations in blood and seminal plasma with various semen parameters in infertile subjects

    International Nuclear Information System (INIS)

    Ali, H.; Ahmed, M.; Baig, M.; Ali, M.

    2007-01-01

    To find out relationship of zinc concentrations in blood and seminal plasma with various semen parameters between fertile and infertile men. (JPMC), Karachi and Department of Biochemistry. Basic Medical Sciences Institute, JPMC, Karachi. Fifty eight primary infertile male subjects, without any treatment, who had regular unprotected intercourse for at least 12 months without conception with their partners, aged 20-40 years, were selected from Infertility Clinic Jinnah Postgraduate Medical Center, Karachi. After semen analyses they were grouped as, oligospermic (30), and azoospermic (28). Twenty five known fertile male selected from general population and after semen analysis were taken as normospermic control group. Semen analyzed according to WHO criteria. Serum and seminal plasma zinc were estimated by 5Br. PAPS Colorimetric method. This study showed significant difference in serum and seminal zinc levels in normospermic, oligospermic (p<0.05) and azoospermic (p<0.005). Seminal plasma zinc showed a positive correlation with sperm count and negative with sperm motility in normospermic and oligospermic and negative correlation with volume, pH, WBC concentration in all three groups. There was no correlation found with sperm morphology. On the basis of the findings of this study and those of other reports, zinc may contribute to fertility through its significant effects on various semen parameters. It seems that the estimation of seminal plasma zinc may help in investigation and treatment of infertile males. (author)

  17. Achieving uniform layer deposition by atmospheric-pressure plasma-enhanced chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae-Ok [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Kang, Woo Seok, E-mail: kang@kimm.re.kr [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Department of Environment & Energy Mechanical Engineering, University of Science & Technology (UST), Daejeon 305-350 (Korea, Republic of); Hur, Min; Lee, Jin Young [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Song, Young-Hoon [Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 305-343 (Korea, Republic of); Department of Environment & Energy Mechanical Engineering, University of Science & Technology (UST), Daejeon 305-350 (Korea, Republic of)

    2015-12-31

    This work investigates the use of plasma-enhanced chemical vapor deposition under atmospheric pressure for achieving uniform layer formation. Electrical and optical measurements demonstrated that the counterbalance between oxygen and precursors maintained the homogeneous discharge mode, while creating intermediate species for layer deposition. Several steps of the deposition process of the layers, which were processed on a stationary stage, were affected by flow stream and precursor depletion. This study showed that by changing the flow streamlines using substrate stage motion uniform layer deposition under atmospheric pressure can be achieved. - Highlights: • Zirconium oxide was deposited by atmospheric-pressure plasma-enhanced chemical vapor deposition. • Homogeneous plasma was maintained by counterbalancing between discharge gas and precursors. • Several deposition steps were observed affected by the gas flow stream and precursor depletion. • Thin film layer was uniformly grown when the substrate underwent a sweeping motion.

  18. Plasma ET-1 Concentrations are Elevated in Patients with Hypertension - Meta-Analysis of Clinical Studies.

    Science.gov (United States)

    Xu, Mei; Lu, Yong-Ping; Hasan, Ahmed Abdallah; Hocher, Berthold

    2017-01-01

    A recent study revealed that global overexpression of ET-1 causes a slight reduction in systemic blood pressure. Moreover, heterozygous ET-1 knockout mice are hypertensive. The role of ET-1 in human hypertension was so far not addressed by a strict meta-analysis of published human clinical studies. We included studies published between January 1, 1990 and February 28, 2017. We included case control studies analyzing untreated essential hypertension or hypertensive patients where antihypertensive medication was discontinued for at least two weeks. Based on the principle of Cochrane systematic reviews, case control studies (CCSs) in PubMed (Medline) and Google Scholar designed to identify the role of endothelin-1 (ET-1) in the pathophysiological of hypertension were screened. Review Manager Version 5.0 (Rev-Man 5.0) was applied for statistical analysis. Mean difference and 95% confidence interval (CI) were shown in inverse variance (IV) fixed-effects model or IV random-effects models. Eleven studies fulfilling our in- and exclusion criteria were eligible for this meta-analysis. These studies included 450 hypertensive patients and 328 controls. Our meta-analysis revealed that ET-1 plasma concentrations were higher in hypertensive patients as compared to the control patients [mean difference between groups 1.57 pg/mL, 95%CI [0.47∼2.68, P = 0.005]. These finding were driven by patients having systolic blood pressure higher than 160 mmHg and diastolic blood pressure higher than 100 mmHg. This meta-analysis showed that hypertensive patients do have elevated plasma ET-1 concentrations. This finding is driven by those patients with high systolic/diastolic blood pressure. Given that the ET-1 gene did not appear in any of the whole genome association studies searching for hypertension associated gene loci, it is very likely that the elevated plasma ET-1 concentrations in hypertensive patients are secondary to hypertension and may reflect endothelial cell damage. © 2017 The

  19. Improving Blood Plasma Glycoproteome Coverage by Coupling Ultracentrifugation Fractionation to Electrostatic Repulsion-Hydrophilic Interaction Chromatography Enrichment

    NARCIS (Netherlands)

    Adav, Sunil S.; Hwa, Ho Hee; De Kleijn, Dominique; Sze, Siu Kwan

    2015-01-01

    Blood plasma is considered to be an excellent source of disease biomarkers because it contains proteins, lipids, metabolites, cell, and cell-derived extracellular vesicles from different cellular origins including diseased tissues. Most secretory and membranous proteins that can be found in plasma

  20. Clinical evaluation of a 51Cr-labeled red blood cell survival test for in vivo blood compatibility testing

    International Nuclear Information System (INIS)

    Pineda, A.A.; Dharkar, D.D.; Wahner, H.W.

    1984-01-01

    Modified red blood cell survival studies with use of 51Cr were performed in three groups of subjects. Group 1 consisted of normal subjects who were given labeled autologous blood, group 2 were subjects in need of blood transfusions and given labeled ABO and Rh crossmatch-compatible blood, and group 3 were patients in need of blood transfusion but in whom problems arose in finding compatible blood. The results of the studies suggest that for patients with blood compatibility problems, normal red blood cell survival values at 1 hour do not exclude the possibility of severe hemolysis 24 hours later. Thus, if a 1-hour test result is normal, the procedure should be extended routinely to 24 hours. Moreover, the test can be used to evaluate the clinical importance of antibodies. We showed that anti-Yka and anti-Lan were clinically significant, but high-titer, low-avidity antibodies, anti-Kna, anti-I, and anti-HI were clinically insignificant in the cases studied. This finding emphasizes the importance of an in vivo test for the final compatibility evaluation in complicated blood replacement problems

  1. Comparison of human whole blood, plasma, and serum matrices for the determination of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and other fluorochemicals

    International Nuclear Information System (INIS)

    Ehresman, David J.; Froehlich, John W.; Olsen, Geary W.; Chang, Shu-Ching; Butenhoff, John L.

    2007-01-01

    Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perfluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methods were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2:1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells

  2. Recovery from Bell Palsy after Transplantation of Peripheral Blood Mononuclear Cells and Platelet-Rich Plasma

    OpenAIRE

    Seffer, Istvan; Nemeth, Zoltan

    2017-01-01

    Summary: Peripheral blood mononuclear cells (PBMCs) are multipotent, and plasma contains growth factors involving tissue regeneration. We hypothesized that transplantation of PBMC-plasma will promote the recovery of paralyzed facial muscles in Bell palsy. This case report describes the effects of PBMC-plasma transplantations in a 27-year-old female patient with right side Bell palsy. On the affected side of the face, the treatment resulted in both morphological and functional recovery includi...

  3. Radioimmunoassay and chemical ionization/mass spectrometry compared for plasma cortisol determination

    International Nuclear Information System (INIS)

    Lindberg, C.; Johnson, S.; Hedner, P.; Gustafsson, A.

    1982-01-01

    A method is described for determination of cortisol in plasma and urine, based on chemical ionization/mass spectrometry with deuterium-labeled cortisol as the internal standard. The within-run precision (CV) was 2.5-5.7%, the between-run precision 4.6%. Results by this method were compared with those by a radioimmunological method (RIANEN Cortisol, New England Nuclear) for 395 plasma samples. The latter method gave significantly higher (approx. 25%) cortisol values

  4. Initial blood lactate correlates with carboxyhemoglobin and clinical severity in carbon monoxide poisoned patients.

    Science.gov (United States)

    Cervellin, Gianfranco; Comelli, Ivan; Rastelli, Gianni; Picanza, Alessandra; Lippi, Giuseppe

    2014-12-01

    The aim of this study was to assess the role of blood lactate levels at admission in carbon monoxide (CO)-poisoned patients for establishing severity of poisoning and short term prognosis. All cases of CO poisoning visited in the emergency department during the years 2012 and 2013 were retrieved from the hospital database. The concentration of COHb and lactate was assessed in arterial blood in all patients with suspected CO poisoning, along with the plasma concentration of troponin I (TnI). The control population for TnI results consisted in 125 blood donors. Twenty three (61%) out of 38 CO-poisoned patients underwent hyperbaric oxygen (HBO) treatment, and 10 (26%) were admitted to a hospital ward. A significant correlation was found between lactate and COHb (r=0.54; p99th percentile compared to 2% controls (p=0.003). The odds ratio for detectable TnI and TnI >99th percentile in CO-poisoned patients were 13.1 (p<0.001) and 7.6 (p=0.006), respectively. Initial blood lactate level may be useful for risk stratification of CO-poisoned patients, especially for predicting hospitalization. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Nitrate-Rich Vegetables Increase Plasma Nitrate and Nitrite Concentrations and Lower Blood Pressure in Healthy Adults.

    Science.gov (United States)

    Jonvik, Kristin L; Nyakayiru, Jean; Pinckaers, Philippe Jm; Senden, Joan Mg; van Loon, Luc Jc; Verdijk, Lex B

    2016-05-01

    Dietary nitrate is receiving increased attention due to its reported ergogenic and cardioprotective properties. The extent to which ingestion of various nitrate-rich vegetables increases postprandial plasma nitrate and nitrite concentrations and lowers blood pressure is currently unknown. We aimed to assess the impact of ingesting different nitrate-rich vegetables on subsequent plasma nitrate and nitrite concentrations and resting blood pressure in healthy normotensive individuals. With the use of a semirandomized crossover design, 11 men and 7 women [mean ± SEM age: 28 ± 1 y; mean ± SEM body mass index (BMI, in kg/m(2)): 23 ± 1; exercise: 1-10 h/wk] ingested 4 different beverages, each containing 800 mg (∼12.9 mmol) nitrate: sodium nitrate (NaNO3), concentrated beetroot juice, a rocket salad beverage, and a spinach beverage. Plasma nitrate and nitrite concentrations and blood pressure were determined before and up to 300 min after beverage ingestion. Data were analyzed using repeated-measures ANOVA. Plasma nitrate and nitrite concentrations increased after ingestion of all 4 beverages (P nitrate concentrations were similar for all treatments (all values presented as means ± SEMs: NaNO3: 583 ± 29 μmol/L; beetroot juice: 597 ± 23 μmol/L; rocket salad beverage: 584 ± 24 μmol/L; spinach beverage: 584 ± 23 μmol/L). Peak plasma nitrite concentrations were different between treatments (NaNO3: 580 ± 58 nmol/L; beetroot juice: 557 ± 57 nmol/L; rocket salad beverage: 643 ± 63 nmol/L; spinach beverage: 980 ± 160 nmol/L; P = 0.016). When compared with baseline, systolic blood pressure declined 150 min after ingestion of beetroot juice (from 118 ± 2 to 113 ± 2 mm Hg; P nitrate-rich beetroot juice, rocket salad beverage, and spinach beverage effectively increases plasma nitrate and nitrite concentrations and lowers blood pressure to a greater extent than sodium nitrate. These findings show that nitrate-rich vegetables can be used as dietary nitrate

  6. Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Hypertension, a common cardiovascular disease (CVD) risk factor, is usually diagnosed and treated based on blood pressure readings obtained in the clinic setting. Blood pressure may differ considerably when measured in the clinic versus outside of the clinic setting. Over the past several decades, evidence has accumulated on two approaches for measuring out-of-clinic blood pressure: ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM). Blood pressure measures on ABPM and HBPM each have a stronger association with CVD outcomes than clinic blood pressure. Controversy exists whether ABPM or HBPM is superior for estimating CVD risk, and under what circumstances these methods should be used in clinical practice for assessing out-of-clinic blood pressure. This review describes ABPM and HBPM procedures, the blood pressure phenotypic measures that can be ascertained, and the evidence that supports the use of each approach to measure out-of-clinic blood pressure. This review also describes barriers to the successful implementation of ABPM and HBPM in clinical practice, proposes core competencies for the conduct of these procedures, and highlights important areas for future research. PMID:26457954

  7. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    International Nuclear Information System (INIS)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-01-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm 3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  8. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    Science.gov (United States)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-06-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  9. COMPARISON OF WHOLE BLOOD AND PLASMA GLUCOSE CONCENTRATIONS IN GREEN TURTLES ( CHELONIA MYDAS) DETERMINED USING A GLUCOMETER AND A DRY CHEMISTRY ANALYZER.

    Science.gov (United States)

    Perrault, Justin R; Bresette, Michael J; Mott, Cody R; Stacy, Nicole I

    2018-01-01

    :  We compared glucose concentrations in whole blood and plasma from green turtles ( Chelonia mydas) using a glucometer with plasma glucose analyzed by dry chemistry analyzer. Whole blood glucose (glucometer) and plasma glucose (dry chemistry) had the best agreement ( r s =0.85) and a small negative bias (-0.08 mmol/L).

  10. Patterned growth of carbon nanotubes obtained by high density plasma chemical vapor deposition

    Science.gov (United States)

    Mousinho, A. P.; Mansano, R. D.

    2015-03-01

    Patterned growth of carbon nanotubes by chemical vapor deposition represents an assembly approach to place and orient nanotubes at a stage as early as when they are synthesized. In this work, the carbon nanotubes were obtained at room temperature by High Density Plasmas Chemical Vapor Deposition (HDPCVD) system. This CVD system uses a new concept of plasma generation, where a planar coil coupled to an RF system for plasma generation was used with an electrostatic shield for plasma densification. In this mode, high density plasmas are obtained. We also report the patterned growth of carbon nanotubes on full 4-in Si wafers, using pure methane plasmas and iron as precursor material (seed). Photolithography processes were used to pattern the regions on the silicon wafers. The carbon nanotubes were characterized by micro-Raman spectroscopy, the spectra showed very single-walled carbon nanotubes axial vibration modes around 1590 cm-1 and radial breathing modes (RBM) around 120-400 cm-1, confirming that high quality of the carbon nanotubes obtained in this work. The carbon nanotubes were analyzed by atomic force microscopy and scanning electron microscopy too. The results showed that is possible obtain high-aligned carbon nanotubes with patterned growth on a silicon wafer with high reproducibility and control.

  11. Investigation Of Arterial Blood Pressure Level And Metabolic Indices In Patients With Arterial Hypertension At Pharmacotherapy With Antihypertensive Medicines Of Various Chemical Structure

    Directory of Open Access Journals (Sweden)

    G.Kh. Glybochko

    2009-12-01

    Full Text Available The research goal is to carry on the comparative analysis of medicines of various chemical structure, Telmisar-tan and Bisoprolol, and to reveal their effect on the arterial blood pressure level and the indices of various metabolic processes in patients with arterial hypertension. 60 out-patients with arterial hypertension (stage II risk III both males and females aged 33-55 have been under study taking Telmisartan and Bisoprolol for 3 months. While treating the patients the arterial blood pressure level control and biochemical investigations for determination the indices of metabolic processes have been carried out. The investigated medications have provided the decrease of systolic and diastolic arterial pressure parameters, the increase of concentration of total and ionized calcium, chlorine ions, urea and total bilirubin in blood plasma. Therapy with Telmisartan has shown more significant increase of potassium level in erythro-cytes, decrease of levels of natrium, glucose, glycolized hemoglobin and triglycerides and increased contents of alani-naminotransferase and aspartataminotransferase. The course of therapy with Bisoprolol has restored the normal level of magnesium in blood plasma, has not have any influence on carbohydrate and lipid metabolism, increased the level of alaninaminotransferase and significantly increased the contents of total and ionized calcium, urea and creatinine. 3-months therapy with Telmisartan and Bisoprolol has proved the decrease of systolic and diastolic arterial pressure in patients with arterial hypertension. The medications under study have had active and variable effects on metabolic indices

  12. Long-term lead elimination from plasma and whole blood after poisoning.

    Science.gov (United States)

    Rentschler, Gerda; Broberg, K; Lundh, T; Skerfving, S

    2012-04-01

    Blood lead (B-Pb), one of the most used toxicological biomarker all kind, has serious limitations. Thus, the objective is to evaluate whether plasma lead (P-Pb) is more adequate. A long-term follow-up study of five cases of lead poisoning. P-Pb was analysed by inductively coupled plasma mass spectrometry. Kinetics after end of exposure was modelled. P-Pb at severe poisoning was about 20 μg/L; haematological effects at about 5 μg/L. Biological half-time of P-Pb was about 1 month; B-Pb decay was much slower. P-Pb is a valuable biomarker of exposure to and risk, particularly at high exposure.

  13. Determination of GABA and vigabatrin in human plasma by a rapid and simple HPLC method: correlation between clinical response to vigabatrin and increase in plasma GABA.

    Science.gov (United States)

    Löscher, W; Fassbender, C P; Gram, L; Gramer, M; Hörstermann, D; Zahner, B; Stefan, H

    1993-03-01

    The novel antiepileptic drug vigabatrin (Sabril) acts by inhibiting degradation of the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), increasing the GABA concentrations in the brain. Because the GABA degrading enzyme GABA aminotransferase (GABA-T) is also present in peripheral tissues, including blood platelets, measurement of plasma GABA levels might be a useful indication of the pharmacological response to vigabatrin during therapeutic monitoring. However, because of the very low concentrations of GABA in plasma, the few methods available for plasma GABA analysis are time-consuming, difficult to perform and/or not selective enough because of potential interference with other plasma constituents. In the present study, a rapid, selective and sensitive amino acid analysis HPLC method has been developed for plasma GABA determination with fluorescence detection, using o-phthaldialdehyde as a precolumn derivatizing agent. By employing a 3 microns particle size reversed-phase column and a multi-step gradient system of two solvents, the very low endogenous concentration of GABA in human plasma could be reproducibly quantitated without interference of other endogenous compounds. Incubation of human plasma samples with GABA degrading enzyme(s) resulted in an almost total loss of the GABA peak, thus demonstrating the specificity of the method for GABA analysis. In addition to GABA and other endogenous amino acids, the HPLC method could be used to quantitate plasma levels of vigabatrin. Thus, this improved HPLC amino acid assay might be used to examine whether concomitant monitoring of plasma GABA and vigabatrin is useful for clinical purposes. This was examined in 20 epileptic patients undergoing chronic treatment with vigabatrin. The average plasma GABA level of these 20 patients did not differ significantly from non-epileptic controls. However, when epileptic patients were subdivided according to their clinical response to vigabatrin, vigabatrin responders

  14. Culture of normal human blood cells in a diffusion chamber system II. Lymphocyte and plasma cell kinetics

    International Nuclear Information System (INIS)

    Chikkappa, G.; Carsten, A.L.; Chanana, A.D.; Cronkite, E.P.

    1979-01-01

    Normal human blood leukocytes were cultured in Millipore diffusion chambers implanted into the peritoneal cavities of irradiated mice. The evaluation of survival and proliferation kinetics of cells in lymphyocytic series suggested that the lymphoid cells are formed from transition of small and/or large lymphocytes, and the lymphoblasts from the lymphoid cells. There was also evidence indicating that some of the cells in these two compartments are formed by proliferation. The evaluation of plasmacytic series suggested that the plasma cells are formed from plasmacytoid-lymphocytes by transition, and the latter from the transition of lymphocytes. In addition, relatively a small fraction of cells in these two compartments are formed by proliferation. mature plasma cells do not and immature plasma cells do proliferate. Estimation of magnitude of plasma cells formed in the cultures at day 18 indicated that at least one plasma cell is formed for every 6 normal human blood lymphocytes introduced into the culture

  15. Plasma treatment of polymers for modifying haemocompatibility

    International Nuclear Information System (INIS)

    Wilson, D.J.

    2000-03-01

    The primary objective of this study was to investigate changes in the thrombogenicity of four materials, PTFE, PDMS, PEU and UHMW-PE induced by plasma treatments. In particular, correlations were sought between the chemical and topographical alterations to the materials surface caused by exposure to plasmas and the observed changes of blood response. Each material was treated in O 2 , Ar, N 2 and NH 3 discharges, the system pressure, treatment times, gas flow rates and plasma power ( 51 Cr labelled platelets and (ii) platelet aggregation and release of microparticles by flow cytometry, after labelling with anti-CD62 and anti-CD41 antibodies, in whole blood perfused in a cone and plate viscometer at a physiologically relevant shear rate (500 s -1 ). In addition, quasi-static evaluation was carried out by contact phase activation and assessed by PTT assays. Contact with the 'as-received' materials resulted in activation of the blood. Moreover, plasma treatment resulted in further modifications of both the surface and fluid phase responses for example, a reduction in the number of adhered platelets and a expression of p-selectin compared with the as-received surfaces attributed to changes in surface chemistry. (author)

  16. Plasma-enhanced chemical vapor deposition for YBCO film fabrication of superconducting fault-current limiter

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Byung Hyuk; Kim, Chan Joong

    2006-05-15

    Since the high-temperature superconductor of oxide type was founded, many researches and efforts have been performed for finding its application field. The YBCO superconducting film fabricated on economic metal substrate with uniform critical current density is considered as superconducting fault-current limiter (SFCL). There are physical and chemical processes to fabricate superconductor film, and it is understood that the chemical methods are more economic to deposit large area. Among them, chemical vapor deposition (CVD) is a promising deposition method in obtaining film uniformity. To solve the problems due to the high deposition temperature of thermal CVD, plasma-enhanced chemical vapor deposition (PECVD) is suggested. This report describes the principle and fabrication trend of SFCL, example of YBCO film deposition by PECVD method, and principle of plasma deposition.

  17. The clinical and mammographic features of plasma cell mastitis

    International Nuclear Information System (INIS)

    Wu Xiurong; Luo Xiaohua; Yu Xuming; Zhong Shan; Huang Yufan; Wu Xinyi; Lin Yubin

    2007-01-01

    Objective: To investigate the clinical and mammographic features of plasma cell mastitis. Methods: Twenty-five patients (28 lesions) with histologically confirmed plasma cell mastitis, aged from 26 to 70 years (mean age 41 years), were examined with X-ray mammography. The clinical manifestations and imaging features were retrospectively reviewed. Results: No case was in lactation. The painful irregular masses, ranged from 1.3 to 8cm in size, were found in 22 patients, while 3 patients with acute episode. Recurrent episodes of breast masses were noted in 4 patients. Based on the mammographic appearances, the plasma cell mastitis were classified as the following four types: inflammation-like type (2/28), ductal ectasia type (3/28), focal infiltration type (10/28) and nodular type (13/28). The valuable radiographic signs: (1) An asymmetrically increased density along the lactiferous duct with a flame-like appearance, inhomogeneous low density tubular structures and scattered stick-shape calcifications. (2) Architectural distortion and oil cysts formation in adjacent area, (3) Subareolar ductal ectasia. Conclusions: The clinical and mammographic characteristics of plasma cell mastitis are critical to avoiding unnecessary surgery. Histopathological result is needed for the diagnosis in patients highly suspected of malignancy. (authors)

  18. RF-plasma vapor deposition of siloxane on paper. Part 2: Chemical evolution of paper surface

    International Nuclear Information System (INIS)

    Sahin, Halil Turgut

    2013-01-01

    Highlights: ► Investigate the detailed RF-cold plasma surface modified paper by XPS and ATR-FTIR. ► Some chemical analysis of RF-cold plasma surface modified paper after RF plasma treatment. ► Identify the connection between RF plasma treatment and the surface chemistry of paper surface. - Abstract: Survey and high-resolution (HR) XPS studies indicate that OMCTSO plasma treatment created a new silicon containing functional groups and changed the hydroxyl content on the surface of paper. Four intense survey XPS spectrum peaks were observed for the OMCTSO plasma treated paper. They were the Si 2p at 100 eV, Si 2s at 160 eV, C 1s at 285 eV, and O 1s at 525 eV for the plasma modified surface. It was realized that the macromolecular chain-breaking mechanisms and plasma-induced etching processes control the number and the availability of OH-functionalities during OMCTSO plasma exposure on paper. The reaction, initiated by these species, depends mainly on the nature of chemicals in the plasma as well as on the energy level of the plasma and the nature of the surface effects in the modification of the paper. The ATR-FTIR spectrum of paper treated with OMCTSO plasma has characteristic absorption bands attributed to the Si-O and Si-O-Si formations on the surface.

  19. Development and Testing of a High Capacity Plasma Chemical Reactor in the Ukraine

    Energy Technology Data Exchange (ETDEWEB)

    Reilly, Raymond W.

    2012-07-30

    This project, Development and Testing of a High Capacity Plasma Chemical Reactor in the Ukraine was established at the Kharkiv Institute of Physics and Technology (KIPT). The associated CRADA was established with Campbell Applied Physics (CAP) located in El Dorado Hills, California. This project extends an earlier project involving both CAP and KIPT conducted under a separate CRADA. The initial project developed the basic Plasma Chemical Reactor (PCR) for generation of ozone gas. This project built upon the technology developed in the first project, greatly enhancing the output of the PCR while also improving reliability and system control.

  20. Clinical Considerations in the Assessment of Adolescent Chemical Dependency.

    Science.gov (United States)

    Winters, Ken

    1990-01-01

    Discusses relevant research findings of clinical assessment of adolescent chemical dependency so that service providers can better address these concerns. Three major issues are discussed: the definition of adolescent chemical dependency, clinical domains of assessment (chemical use problem severity, precipitating and perpetuating risk factors,…

  1. Chemical reactions inside the plasma chamber of the SEAFP reactor plant models

    International Nuclear Information System (INIS)

    Gay, J.M.; Ebert, E.; Mazille, F.

    1995-01-01

    Loss of coolant or loss of vacuum accidents may lead to chemical reactions between the protecting materials of the plasma facing components and air or water. A production of energy, reaction products and hydrogen may be induced. The paper defines the operating conditions and chemical reactions and presents the main results from the underlying studies. (orig.)

  2. State-wide hospital clinical laboratory plan for measuring cholinesterase activity for individuals suspected of exposure to nerve agent chemical weapons.

    Science.gov (United States)

    Wu, Alan H B; Smith, Andrew; McComb, Robert; Bowers, George N; Makowski, Gregory S; McKay, Charles A; Vena, Jason; McDonagh, John; Hopfer, Sidney; Sena, Salvatore F; Malkus, Herbert; Forte, Elaine; Kelly, Katherine

    2008-02-01

    Hospital laboratories currently lack the capacity to provide emergency determination of cholinesterase activity. We have developed a hospital-based 3-tiered system to test plasma for butyrylcholinesterase (BChE) activity and whole blood for red cell acetylcholinesterase (AChE) activity using available technology and personnel. Interagency communications, toxidrome definition, and patient triage will be coordinated by the Connecticut Department of Public Health and the Poison Control Center. Initial BChE data documents good precision between institutions (coefficient of variation chemical terrorism or large scale HazMat events.

  3. The relationship between blood viscosity and blood pressure in a random sample of the population aged 55 to 74 years.

    Science.gov (United States)

    Fowkes, F G; Lowe, G D; Rumley, A; Lennie, S E; Smith, F B; Donnan, P T

    1993-05-01

    Blood viscosity is elevated in hypertensive subjects, but the association of viscosity with arterial blood pressure in the general population, and the influence of social, lifestyle and disease characteristics on this association, are not established. In the Edinburgh Artery Study, 1592 men and women aged 55-74 years selected randomly from the general population attended a university clinic. A fasting blood sample was taken for the measurement of blood viscosity and its major determinants (haematocrit, plasma viscosity and fibrinogen). Systolic pressure was related univariately to blood viscosity (P viscosity (P index. Diastolic pressure was related univariately to blood viscosity (P viscosity (P viscosity and systolic pressure was confined to males. Blood viscosity was associated equally with systolic and diastolic pressures in males, and remained independently related on multivariate analysis adjusting for age, sex, body mass index, social class, smoking, alcohol intake, exercise, angina, HDL and non-HDL cholesterol, diabetes mellitus, plasma viscosity, fibrinogen, and haematocrit.

  4. New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: quality of blood components.

    Science.gov (United States)

    Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A

    2014-10-01

    TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.

  5. Chemically different non-thermal plasmas target distinct cell death pathways

    Czech Academy of Sciences Publication Activity Database

    Lunov, O.; Zablotskyy, V.; Chrupina, O.; Lunova, M.; Jirsa, M.; Dejneka, A.; Kubinová, Šárka

    2017-01-01

    Roč. 7, apr (2017), s. 600 ISSN 2045-2322 R&D Projects: GA MŠk(CZ) LO1309 Institutional support: RVO:68378041 Keywords : chemically different * non-thermal plasmas * target distinct cell death pathways Subject RIV: FP - Other Medical Disciplines OBOR OECD: Biophysics Impact factor: 4.259, year: 2016

  6. Liver insulinase and insulin-like activity of the blood plasma in irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Zhikhareva, A I; Dokshina, G A [Tomskij Gosudarstvennyj Univ. (USSR)

    1975-05-01

    Comparative quantitative analysis of the functional effect of radiation on the activity of liver insulinase of irradiated rats has shown that the insulinase activity of the blood plasma decreases (21-45%) one to three days after the exposure at betatron. Insulinase activity of the liver extracts is also inhibited (16-22%) as compared to intact liver extracts. Twelve days after the exposure and later, insulin-like activity of the plasma and the enzyme activity increase up to 37 per cent.

  7. Basic characteristics of plasma rich in growth factors (PRGF): blood cell components and biological effects.

    Science.gov (United States)

    Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Kawase, Tomoyuki

    2016-11-01

    Platelet-rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers ( N  = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84-fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79- and 5.51-fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose-dependent stimulation of periosteal cell proliferation in vitro.

  8. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  9. Plasma-chemical simulation of negative corona near the inception voltage

    Science.gov (United States)

    Pontiga, Francisco; Duran-Olivencia, Francisco J.; Castellanos, Antonio

    2013-09-01

    The spatiotemporal development of Trichel pulses in oxygen between a spherical electrode and a grounded plane has been simulated using a fluid approximation that incorporates the plasma chemistry of the electrical discharge. Elementary plasma processes, such as ionization, electron attachment, electron detachment, recombination between ions and chemical reactions between neutral species, are all included in a chemical model consisting of 55 reactions between 8 different species (electrons, O2+,O2-,O3-,O-, O2, O, O3). Secondary emission at the cathode by the impact of positive ions and photons is also considered. The spatial distribution of species is computed in three dimensions (2D-axysimmetrical) by solving Poisson's equation for the electric field and the continuity equations for the species, with the inclusion of the chemical gain/loss rate due to the particle interaction. The results of the simulation reveal the interplay between the different negative ions during the development of every Trichel pulse, and the rate of production of atomic oxygen and ozone by the corona discharge. This work was supported by the Consejeria de Innovacion, Ciencia y Empresa (Junta de Andalucia) and by the Ministerio de Ciencia e Innovacion, Spain, within the European Regional Development Fund contracts FQM-4983 and FIS2011-25161.

  10. Plasma Biomarkers Discriminate Clinical Forms of Multiple Sclerosis

    Science.gov (United States)

    Tejera-Alhambra, Marta; Casrouge, Armanda; de Andrés, Clara; Seyfferth, Ansgar; Ramos-Medina, Rocío; Alonso, Bárbara; Vega, Janet; Fernández-Paredes, Lidia; Albert, Matthew L.; Sánchez-Ramón, Silvia

    2015-01-01

    Multiple sclerosis, the most common cause of neurological disability in young population after trauma, represents a significant public health burden. Current challenges associated with management of multiple sclerosis (MS) patients stem from the lack of biomarkers that might enable stratification of the different clinical forms of MS and thus prompt treatment for those patients with progressive MS, for whom there is currently no therapy available. In the present work we analyzed a set of thirty different plasma cytokines, chemokines and growth factors present in circulation of 129 MS patients with different clinical forms (relapsing remitting, secondary progressive and primary progressive MS) and 53 healthy controls, across two independent cohorts. The set of plasma analytes was quantified with Luminex xMAP technology and their predictive power regarding clinical outcome was evaluated both individually using ROC curves and in combination using logistic regression analysis. Our results from two independent cohorts of MS patients demonstrate that the divergent clinical and histology-based MS forms are associated with distinct profiles of circulating plasma protein biomarkers, with distinct signatures being composed of chemokines and growth/angiogenic factors. With this work, we propose that an evaluation of a set of 4 circulating biomarkers (HGF, Eotaxin/CCL11, EGF and MIP-1β/CCL4) in MS patients might serve as an effective tool in the diagnosis and more personalized therapeutic targeting of MS patients. PMID:26039252

  11. Radioimmunossay of hormones and metabolites in blood serum and plasma

    International Nuclear Information System (INIS)

    Khare, G.P.

    1978-01-01

    Hormones or metabolites which are capable of producing antibodies can be detected and precisely quantitated by this method. Antibodies, to various hormones or metabolites whose assay is desired, are adsorbed onto commercially available imitation or cultured pearls. These pearls coated with antibody are contacted with a buffered reaction mixture containing blood serum or plasma specimen and respective radioactive antigen. The entire reaction is allowed to proceed for a time sufficient to form antigen (radioactive or non-radioactive)-antibody complex. These complexes on the pearls are washed and the total amount of radioactivity emanating from the complex is measured. This is indicative of the extent of binding of radioactive antigen and provides an indirect correlation of the amount of non-radioactive antigen present in the serum or plasma sample

  12. Interpretation of Blood Microbiology Results - Function of the Clinical Microbiologist.

    Science.gov (United States)

    Kristóf, Katalin; Pongrácz, Júlia

    2016-04-01

    The proper use and interpretation of blood microbiology results may be one of the most challenging and one of the most important functions of clinical microbiology laboratories. Effective implementation of this function requires careful consideration of specimen collection and processing, pathogen detection techniques, and prompt and precise reporting of identification and susceptibility results. The responsibility of the treating physician is proper formulation of the analytical request and to provide the laboratory with complete and precise patient information, which are inevitable prerequisites of a proper testing and interpretation. The clinical microbiologist can offer advice concerning the differential diagnosis, sampling techniques and detection methods to facilitate diagnosis. Rapid detection methods are essential, since the sooner a pathogen is detected, the better chance the patient has of getting cured. Besides the gold-standard blood culture technique, microbiologic methods that decrease the time in obtaining a relevant result are more and more utilized today. In the case of certain pathogens, the pathogen can be identified directly from the blood culture bottle after propagation with serological or automated/semi-automated systems or molecular methods or with MALDI-TOF MS (matrix-assisted laser desorption-ionization time of flight mass spectrometry). Molecular biology methods are also suitable for the rapid detection and identification of pathogens from aseptically collected blood samples. Another important duty of the microbiology laboratory is to notify the treating physician immediately about all relevant information if a positive sample is detected. The clinical microbiologist may provide important guidance regarding the clinical significance of blood isolates, since one-third to one-half of blood culture isolates are contaminants or isolates of unknown clinical significance. To fully exploit the benefits of blood culture and other (non- culture

  13. Deterministic hydrodynamics: Taking blood apart

    Science.gov (United States)

    Davis, John A.; Inglis, David W.; Morton, Keith J.; Lawrence, David A.; Huang, Lotien R.; Chou, Stephen Y.; Sturm, James C.; Austin, Robert H.

    2006-10-01

    We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 μm/sec and volume rates up to 1 μl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma. cells | plasma | separation | microfabrication

  14. UPLC-ESI-QTOF/MS and multivariate data analysis for blood plasma and serum metabolomics: effect of experimental artefacts and anticoagulant

    DEFF Research Database (Denmark)

    Barri, Thaer; Dragsted, Lars Ove

    2013-01-01

    agents, e.g. heparin, EDTA and citrate. In the present study, we looked into metabolite and other differences in matched serum and plasma samples and different plasma preparations by using untargeted UPLC-ESI-QTOF/MS profiling and multivariate data analysis (PCA and OPLS-DA). Metabolite differences......Clotting and anticoagulation of blood samples may give rise to different metabolic profiles of serum and plasma samples, respectively. The anticoagulant used for blood plasma preparation may affect the resulting metabolic profile due to different mechanisms involved in anticoagulation by various...... between serum and plasma samples were mainly related to small peptides reflecting presence or absence of coagulation. Only subtle metabolite differences between the different plasma preparations were noticed, which were primarily related to ion suppression or enhancement caused by citrate and EDTA...

  15. Analysis of blood spots for polyfluoroalkyl chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Kayoko; Wanigatunga, Amal A.; Needham, Larry L. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Calafat, Antonia M., E-mail: acalafat@cdc.gov [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States)

    2009-12-10

    Polyfluoroalkyl chemicals (PFCs) have been detected in humans, in the environment, and in ecosystems around the world. The potential for developmental and reproductive toxicities of some PFCs is of concern especially to children's health. In the United States, a sample of a baby's blood, called a 'dried blood spot' (DBS), is obtained from a heel stick within 48 h of a child's birth. DBS could be useful for assessing prenatal exposure to PFCs. We developed a method based on online solid phase extraction coupled with high performance liquid chromatography-isotope dilution tandem mass spectrometry for measuring four PFCs in DBS, perfluorooctane sulfonate (PFOS), perfluorohexane sulfonate, perfluorooctanoate (PFOA), and perfluorononanoate. The analytical limits of detection using one whole DBS ({approx}75 {mu}L of blood) were <0.5 ng mL{sup -1}. To validate the method, we analyzed 98 DBS collected in May 2007 in the United States. PFOS and PFOA were detected in all DBS at concentrations in the low ng mL{sup -1} range. These data suggest that DBS may be a suitable matrix for assessing perinatal exposure to PFCs, but additional information related to sampling and specimen storage is needed to demonstrate the utility of these measures for assessing exposure.

  16. Morphologic and cytochemical characteristics of blood cells and hematologic and plasma biochemical reference ranges in green iguanas.

    Science.gov (United States)

    Harr, K E; Alleman, A R; Dennis, P M; Maxwell, L K; Lock, B A; Bennett, R A; Jacobson, E R

    2001-03-15

    To determine blood cell morphologic characteristics and hematologic and plasma biochemical reference ranges for iguanas housed in a warm indoor and outdoor environment with regular exposure to direct sunlight. Original study. 51 clinically normal iguanas (18 males, 25 females, and 8 juveniles) housed in 3 Florida locations. Blood was collected from the coccygeal or ventral abdominal vein. Any samples that had obvious hemolysis or clot formation were not used. Leukocyte counts were determined manually; other hematologic values were obtained by use of a commercially available cell counter. Plasma biochemical values were determined by use of a spectrophotometric chemistry analyzer. Blood smears were stained with Wright-Giemsa and cytochemical stains for morphologic and cytochemical evaluation. Hematologic ranges were generally higher in this study than previously reported. Thrombocytes were variable in appearance between individuals and sometimes difficult to distinguish from lymphocytes on a Wright-Giemsa preparation. Concentrations of calcium, phosphorus, total protein, globulins, and cholesterol were significantly higher, and the albumin:globulin ratio was significantly lower, in healthy gravid females than in male or nongravid female iguanas. Nongravid females had significantly higher calcium and cholesterol concentrations, compared with males. The calcium:phosphorus ratio was > 1 in all iguanas. Gravid females had a calcium phosphorus product ranging between 210 and 800. Intracytoplasmic inclusions were identified within the erythrocytes of some iguanas. Hematologic ranges for iguanas in this study are higher than those reported for iguanas. Sex and age of the iguana should be considered when evaluating biochemical values. Healthy ovulating and gravid females may have significantly increased electrolyte and protein concentrations, but maintain a calcium:phosphorus ratio > 1.

  17. Chemical changes in the blood of leukemia patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Shah, S.; Khan, S.A.; Khan, M.S.

    2007-01-01

    Blood samples of 10 patients of blood cancer were collected from Combined Military Hospital (CMH), Rawalpindi. These samples of leukemia patients before and after treatments were analyzed for hemoglobin, creatinine, urea, glucose, uric acid, bilirubin, protein, sodium, and potassium using different methods. The mean values for various tested parameters were found to be 8.8 m.mol/L (urea), 214.9 Jimol/L (creatinine), 7.4 m. mol/L (glucose), 40.2 g/L (albumin), 410.2 micro mol/L (uric acid), 24.6 micro mol/L (bilirubin), 138.2 m.mol/L (sodium), 5.04 m.mol/L (potassium) and 9.6 g/dL (hemoglobin). The data revealed that levels of glucose and sodium were within the normal range in all patients whereas blood spectrum for hemoglobin, creatinine, urea, uric acid, bilirubin and potassium showed abnormal results. The results predict that leukemia in the body lead to appreciable and detectable changes in the chemical profile of blood. Some of these changes are mainly caused because of the disease only while others may be due to the disease as well as the treatment phenomenon i.e. effect of medicines. The findings thus obtained provide useful information to the researchers and the specialist doctors of the disease. (author)

  18. Physical-morphological and chemical changes leading to an increase in adhesion between plasma treated polyester fibres and a rubber matrix

    International Nuclear Information System (INIS)

    Krump, H.; Hudec, I.; Jasso, M.; Dayss, E.; Luyt, A.S.

    2006-01-01

    The effects of plasma treatment, used to increase adhesion strength between poly(ethylene terephtalate) (PET) fibres and a rubber matrix, were investigated and compared. Morphological changes as a result of atmospheric plasma treatment were observed using scanning electron microscopy (SEM) and atomic force microscopy (AFM). Wettability analysis using a surface energy evaluation system (SEE system) suggested that the plasma treated fibre was more wetting towards a polar liquid. When treated, these fibres showed a new lamellar crystallization, as shown by a new melting peak using differential scanning calorimetry (DSC). X-ray photoelectron spectroscopy (XPS) has been used to study the chemical effect of inert (argon), active and reactive (nitrogen and oxygen) microwave-plasma treatments of a PET surface. Reactive oxygen plasma treatment by a de-convolution method shows new chemical species that drastically alter the chemical reactivity of the PET surface. These studies have also shown that the surface population of chemical species formed after microwave-plasma treatment is dependent on the plasma gas. All these changes cause better adhesion strength of the PET fibres to the rubber matrix

  19. The material balance of process of plasma-chemical conversion of polymer wastes into synthesis gas

    International Nuclear Information System (INIS)

    Tazmeev, A Kh; Tazmeeva, R N

    2017-01-01

    The process of conversion of polymer wastes in the flow of water-steam plasma which are created by the liquid electrodes plasma generators was experimentally studied. The material balance was calculated. The regularities of the participating of hydrogen and oxygen which contained in the water-steam plasma, in formation of chemical compounds in the final products were revealed. (paper)

  20. The material balance of process of plasma-chemical conversion of polymer wastes into synthesis gas

    Science.gov (United States)

    Tazmeev, A. Kh; Tazmeeva, R. N.

    2017-01-01

    The process of conversion of polymer wastes in the flow of water-steam plasma which are created by the liquid electrodes plasma generators was experimentally studied. The material balance was calculated. The regularities of the participating of hydrogen and oxygen which contained in the water-steam plasma, in formation of chemical compounds in the final products were revealed.

  1. Clinical Validation and Implications of Dried Blood Spot Sampling of Carbamazepine, Valproic Acid and Phenytoin in Patients with Epilepsy

    Science.gov (United States)

    Kong, Sing Teang; Lim, Shih-Hui; Lee, Wee Beng; Kumar, Pasikanthi Kishore; Wang, Hwee Yi Stella; Ng, Yan Lam Shannon; Wong, Pei Shieen; Ho, Paul C.

    2014-01-01

    To facilitate therapeutic monitoring of antiepileptic drugs (AEDs) by healthcare professionals for patients with epilepsy (PWE), we applied a GC-MS assay to measure three AEDs: carbamazepine (CBZ), phenytoin (PHT) and valproic acid (VPA) levels concurrently in one dried blood spot (DBS), and validated the DBS-measured levels to their plasma levels. 169 PWE on either mono- or polytherapy of CBZ, PHT or/and VPA were included. One DBS, containing ∼15 µL of blood, was acquired for the simultaneous measurement of the drug levels using GC-MS. Simple Deming regressions were performed to correlate the DBS levels with the plasma levels determined by the conventional immunoturbimetric assay in clinical practice. Statistical analyses of the results were done using MedCalc Version 12.6.1.0 and SPSS 21. DBS concentrations (Cdbs) were well-correlated to the plasma concentrations (Cplasma): r = 0.8381, 0.9305 and 0.8531 for CBZ, PHT and VPA respectively, The conversion formulas from Cdbs to plasma concentrations were [0.89×CdbsCBZ+1.00]µg/mL, [1.11×CdbsPHT−1.00]µg/mL and [0.92×CdbsVPA+12.48]µg/mL respectively. Inclusion of the red blood cells (RBC)/plasma partition ratio (K) and the individual hematocrit levels in the estimation of the theoretical Cplasma from Cdbs of PHT and VPA further improved the identity between the observed and the estimated theoretical Cplasma. Bland-Altman plots indicated that the theoretical and observed Cplasma of PHT and VPA agreed well, and >93.0% of concentrations was within 95% CI (±2SD); and similar agreement (1∶1) was also found between the observed Cdbs and Cplasma of CBZ. As the Cplasma of CBZ, PHT and VPA can be accurately estimated from their Cdbs, DBS can therefore be used for drug monitoring in PWE on any of these AEDs. PMID:25255292

  2. Effect of Low Dose Gamma Radiation on Some Biochemical Indicators in the Blood Plasma of Chickens

    International Nuclear Information System (INIS)

    Kraljevic, P.; Simpraga, M.; Vilic, M.; Miljanic, S.

    2001-01-01

    Full text: An attempt was made to determine the effect of irradiation of eggs by low dose ionising radiation before incubation on concentration of total protein, glucose and cholesterol in the blood plasma of chickens hatched from irradiated eggs. The eggs of heavy breeding chickens were irradiated by dose of 0.15 Gy gamma radiation ( 60 Co) before incubation. Along with the chickens which were hatched from irradiated eggs, there was the control group of chickens hatched from nonirradiated eggs. All other conditions were the same for the both groups. After hatching, blood samples were taken from the wing vein on days 1, 3, 5, 7, 10, 20, 30 and 42. The concentration of all three parameters was determined spectrophotometrically using Boehringer Mannheim GmbH optimized kits. The concentration of total protein was significantly decreased in the blood plasma of chickens hatched from irradiated eggs on days 3, 7 and 30 and increased only on day 5. The concentration of glucose in the blood plasma was increased in the same chickens on days 1 and 30. The concentration of the cholesterol was decreased in the same chickens on day 7, and increased on day 10. Obtained results indicate that low-dose of gamma radiation has effects on some metabolic processes in the chickens hatched from eggs irradiated before incubation. (author)

  3. Use of pooled blood plasmas in the assessment of fouling resistance

    Czech Academy of Sciences Publication Activity Database

    de los Santos Pereira, Andres; Rodriguez-Emmenegger, Cesar; Surman, František; Riedel, Tomáš; Bologna Alles, A.; Brynda, Eduard

    2014-01-01

    Roč. 4, č. 5 (2014), s. 2318-2321 ISSN 2046-2069 R&D Projects: GA MŠk EE2.3.30.0029; GA ČR GAP106/12/1451; GA ČR GAP205/12/1702; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61389013 Keywords : blood plasma * fouling * biomaterials Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.840, year: 2014

  4. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  5. Recovery from Bell Palsy after Transplantation of Peripheral Blood Mononuclear Cells and Platelet-Rich Plasma.

    Science.gov (United States)

    Seffer, Istvan; Nemeth, Zoltan

    2017-06-01

    Peripheral blood mononuclear cells (PBMCs) are multipotent, and plasma contains growth factors involving tissue regeneration. We hypothesized that transplantation of PBMC-plasma will promote the recovery of paralyzed facial muscles in Bell palsy. This case report describes the effects of PBMC-plasma transplantations in a 27-year-old female patient with right side Bell palsy. On the affected side of the face, the treatment resulted in both morphological and functional recovery including voluntary facial movements. These findings suggest that PBMC-plasma has the capacity of facial muscle regeneration and provides a promising treatment strategy for patients suffering from Bell palsy or other neuromuscular disorders.

  6. Transient spontaneous engraftment of CD34 hematopoietic cord blood stem cells as seen in peripheral blood: treatment of leprosy patients with anemia by placental umbilical cord whole blood transfusion.

    Science.gov (United States)

    Bhattacharya, N

    2006-01-01

    Cord blood, because of its rich mix of fetal and adult hemoglobin, high platelet and white blood cell (WBC) counts, and a plasma filled with cytokine and growth factors, as well as its hypoantigenic nature and altered metabolic profile, has all the potential of a real and safe alternative to adult blood transfusion. Our experience of 74 units (50 ml-146 ml mean, 86 ml +/- 7.6 ml SD, median 80 ml, mean packed cell volume 48 +/- 4.1 SD, mean percent hemoglobin concentration 16.2 g/dl +/- 1.8 g/dl of placental umbilical cord whole blood collection (from 1 April 1999) after lower uterine cesarean section (LUCS) from consenting mothers and transfusion of the same to 16 informed, consenting patients with percent plasma hemoglobin 8 g/dl or less, is presented here. After collection the blood was immediately preserved in the refrigerator and transfused within 72 hours of collection. Fifteen males and one female, aged 12-72 yrs (mean 48.4 yrs) participated: five cases were pausibacillary type (PB) and 11 cases were multibacillary type (MB). The clinical spectrum of the cases varied widely from the tuberculoid to the lepromatous type and one patient presented with gangrene of the leg preceding an auto amputation which was infested with maggots. Each case was approved by the institutional ethical committee and received two to eight units of freshly collected placental umbilical cord blood in one transfusion without encountering any clinical, immunological or non-immunological reaction. Seven days after completion of the placental umbilical cord blood transfusion, the peripheral blood hematopoietic stem cell (CD34) estimation revealed a rise from the pretransfusion base level (.09%), varying from 3.6% to 16.2%, in 75% of the cases, without provoking any clinical graft vs host reaction in any of the leprosy victims. This value returned to normal within three months in most cases.

  7. The influence of ketoacids on plasma creatinine assays in diabetic ketoacidosis

    NARCIS (Netherlands)

    Kemperman, F. A.; Weber, J. A.; Gorgels, J.; van Zanten, A. P.; Krediet, R. T.; Arisz, L.

    2000-01-01

    OBJECTIVE: Analysis of the interference of ketoacids on various routine plasma creatinine assays during a clinical episode of diabetic ketoacidosis (DKA). DESIGN: Observational study. Blood samples were drawn before, during and after standard in-hospital treatment. Plasma creatinine was measured

  8. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  9. Remote plasma-enhanced metalorganic chemical vapor deposition of aluminum oxide thin films

    NARCIS (Netherlands)

    Volintiru, I.; Creatore, M.; Hemmen, van J.L.; Sanden, van de M.C.M.

    2008-01-01

    Aluminum oxide films were deposited using remote plasma-enhanced metalorganic chemical vapor deposition from oxygen/trimethylaluminum mixtures. Initial studies by in situ spectroscopic ellipsometry demonstrated that the aluminum oxide films deposited at temperatures

  10. Blood plasma levels of anterior pituitary hormones of rabbits after apricot seed exposure in vivo

    Directory of Open Access Journals (Sweden)

    Katarína MICHALCOVÁ

    2016-12-01

    Full Text Available The present study describes possible changes in plasma levels of anterior pituitary hormones induced by bitter apricot (Prunus armeniaca L. seeds in young female rabbits in vivo. Prunus armeniaca L. is an important medicinal edible plant species commonly known as “apricot”. The apricot is a member of the Rosaceae and subfamily Prunoideae. It is one of the most delicious and commercially traded fruits in the world. Apricot kernel is the inner part of the seed of the apricot fruit. The kernel is used to produce oil and other chemicals used for medicinal purposes. The seeds are potentially useful in human nutrition and for treatment several diseases especially cancer. In the present study apricot seeds were mixed with feed at different doses 0, 60, 300, 420 mg*kg-1 of body weight. ELISA was used to determine the levels of follicle stimulating hormone (FSH, luteinizing hormone (LH and prolactin (PRL. 58-days application of apricot seeds did not affect the concentration (P≥0.05 of PRL, LH in blood plasma. Significant (P≤0.01 inhibition of FSH levels induced by the seeds was found at the dose of 420 mg*kg-1 but not at 60 and 300 mg*kg-1 of body weight. These results are suggesting that the natural substances present in apricot seeds may be involved in mechanisms of ovarian folliculogenesis.

  11. Modelling chemical reactions in dc plasma inside oxygen bubbles in water

    International Nuclear Information System (INIS)

    Takeuchi, N; Ishii, Y; Yasuoka, K

    2012-01-01

    Plasmas generated inside oxygen bubbles in water have been developed for water purification. Zero-dimensional numerical simulations were used to investigate the chemical reactions in plasmas driven by dc voltage. The numerical and experimental results of the concentrations of hydrogen peroxide and ozone in the solution were compared with a discharge current between 1 and 7 mA. Upon increasing the water vapour concentration inside bubbles, we saw from the numerical results that the concentration of hydrogen peroxide increased with discharge current, whereas the concentration of ozone decreased. This finding agreed with the experimental results. With an increase in the discharge current, the heat flux from the plasma to the solution increased, and a large amount of water was probably vaporized into the bubbles.

  12. Modelling chemical reactions in dc plasma inside oxygen bubbles in water

    Science.gov (United States)

    Takeuchi, N.; Ishii, Y.; Yasuoka, K.

    2012-02-01

    Plasmas generated inside oxygen bubbles in water have been developed for water purification. Zero-dimensional numerical simulations were used to investigate the chemical reactions in plasmas driven by dc voltage. The numerical and experimental results of the concentrations of hydrogen peroxide and ozone in the solution were compared with a discharge current between 1 and 7 mA. Upon increasing the water vapour concentration inside bubbles, we saw from the numerical results that the concentration of hydrogen peroxide increased with discharge current, whereas the concentration of ozone decreased. This finding agreed with the experimental results. With an increase in the discharge current, the heat flux from the plasma to the solution increased, and a large amount of water was probably vaporized into the bubbles.

  13. Multicentre standardisation of a clinical grade procedure for the preparation of allogeneic platelet concentrates from umbilical cord blood

    Science.gov (United States)

    Rebulla, Paolo; Pupella, Simonetta; Santodirocco, Michele; Greppi, Noemi; Villanova, Ida; Buzzi, Marina; De Fazio, Nicola; Grazzini, Giuliano

    2016-01-01

    Background In addition to a largely prevalent use for bleeding prophylaxis, platelet concentrates from adult blood have also been used for many years to prepare platelet gels for the repair of topical skin ulcers. Platelet gel can be obtained by activation of fresh, cryopreserved, autologous or allogeneic platelet concentrates with calcium gluconate, thrombin and/or batroxobin. The high content of tissue regenerative factors in cord blood platelets and the widespread availability of allogeneic cord blood units generously donated for haematopoietic transplant but unsuitable for this use solely because of low haematopoietic stem cell content prompted us to develop a national programme to standardise the production of allogeneic cryopreserved cord blood platelet concentrates (CBPC) suitable for later preparation of clinical-grade cord blood platelet gel. Materials and methods Cord blood units collected at public banks with total nucleated cell counts 150×109/L and volume >50 mL, underwent soft centrifugation within 48 hours of collection. Platelet-rich plasma was centrifuged at high speed to obtain a CBPC with target platelet concentration of 800–1,200×109/L, which was cryopreserved, without cryoprotectant, below −40 °C. Results During 14 months, 13 banks produced 1,080 CBPC with mean (± standard deviation) volume of 11.4±4.4 mL and platelet concentration of 1,003±229×109/L. Total platelet count per CBPC was 11.3±4.9×109. Platelet recovery from cord blood was 47.7±17.8%. About one-third of cord blood units donated for haematopoietic transplant could meet the requirements for preparation of CBPC. The cost of preparation was € 160.92/CBPC. About 2 hours were needed for one technician to prepare four CBPC. Discussion This study yielded valuable scientific and operational information regarding the development of clinical trials using allogeneic CBPC. PMID:26509822

  14. Effects of fruits and vegetables on electolytes and blood pressure of ...

    African Journals Online (AJOL)

    bi-weekly assessment of plasma electrolytes, such as sodium, potassium, chloride and bicarbonate was carried out on the patients. Anthropometric measurements and blood pressure were also assessed biweekly on the patients during their routine clinic attendance. There was a gradual reduction in plasma sodium and ...

  15. An enigmatic clinical presentation of plasma cell granuloma of the oral cavity

    Directory of Open Access Journals (Sweden)

    Pravesh Kumar Jhingta

    2018-01-01

    Full Text Available Plasma cell granuloma is a rare benign lesion characterized by the infiltration of plasma cells; primarily occurring in the lungs. It is also seen to occur in the brain, kidney stomach, heart, and so on but its intraoral occurrence is a rarity. This case report represents one of the uncommon locations in the oral cavity affected by plasma cell granuloma, its clinical and histological features, and establishes the differential diagnosis with other malignant or benign disease entities and planning the treatment accordingly. This report discusses the diagnostic enigma and the associated terminology of plasma cell granulomas and reinforces the need for performing biopsy and a histopathological or immune histochemical study, irrespective of the clinical features and clinical diagnosis of the lesion. In this case a 52-year-old female, presented with gingival enlargement in the mandibular anterior region, treated by excisional biopsy. Histological evaluation revealed plasma cell infiltrates in the connective tissue. The immune-histochemistry revealed kappa and lambda light chains with a polyclonal staining pattern, which confirmed the diagnosis of plasma cell granuloma.

  16. High wavenumber Raman spectroscopic characterization of normal and oral cancer using blood plasma

    Science.gov (United States)

    Pachaiappan, Rekha; Prakasarao, Aruna; Suresh Kumar, Murugesan; Singaravelu, Ganesan

    2017-02-01

    Blood plasma possesses the biomolecules released from cells/tissues after metabolism and reflects the pathological conditions of the subjects. The analysis of biofluids for disease diagnosis becomes very attractive in the diagnosis of cancers due to the ease in the collection of samples, easy to transport, multiple sampling for regular screening of the disease and being less invasive to the patients. Hence, the intention of this study was to apply near-infrared (NIR) Raman spectroscopy in the high wavenumber (HW) region (2500-3400 cm-1) for the diagnosis of oral malignancy using blood plasma. From the Raman spectra it is observed that the biomolecules protein and lipid played a major role in the discrimination between groups. The diagnostic algorithms based on principal components analysis coupled with linear discriminant analysis (PCA-LDA) with the leave-one-patient-out cross-validation method on HW Raman spectra yielded a promising results in the identification of oral malignancy. The details of results will be discussed.

  17. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  18. Regulatory T cell frequency, but not plasma IL-33 levels, represents potential immunological biomarker to predict clinical response to intravenous immunoglobulin therapy.

    Science.gov (United States)

    Maddur, Mohan S; Stephen-Victor, Emmanuel; Das, Mrinmoy; Prakhar, Praveen; Sharma, Varun K; Singh, Vikas; Rabin, Magalie; Trinath, Jamma; Balaji, Kithiganahalli N; Bolgert, Francis; Vallat, Jean-Michel; Magy, Laurent; Kaveri, Srini V; Bayry, Jagadeesh

    2017-03-20

    Intravenous immunoglobulin (IVIG) is a polyspecific pooled immunoglobulin G preparation and one of the commonly used therapeutics for autoimmune diseases including those of neurological origin. A recent report in murine model proposed that IVIG expands regulatory T (T reg ) cells via induction of interleukin 33 (IL-33). However, translational insight on these observations is lacking. Ten newly diagnosed Guillain-Barré syndrome (GBS) patients were treated with IVIG at the rate of 0.4 g/kg for three to five consecutive days. Clinical evaluation for muscular weakness was performed by Medical Research Council (MRC) and modified Rankin scoring (MRS) system. Heparinized blood samples were collected before and 1, 2, and 4-5 weeks post-IVIG therapy. Peripheral blood mononuclear cells were stained for surface CD4 and intracellular Foxp3, IFN-γ, and tumor necrosis factor alpha (TNF-α) and were analyzed by flow cytometry. IL-33 and prostaglandin E2 in the plasma were measured by ELISA. The fold changes in plasma IL-33 at week 1 showed no correlation with the MRC and MRS scores at weeks 1, 2, and ≥4 post-IVIG therapy. Clinical recovery following IVIG therapy appears to be associated with T reg cell response. Contrary to murine study, there was no association between the fold changes in IL-33 at week 1 and T reg cell frequency at weeks 1, 2, and ≥4 post-IVIG therapy. T reg cell-mediated clinical response to IVIG therapy in GBS patients was associated with reciprocal regulation of effector T cells-expressing TNF-α. T reg cell expansion by IVIG in patients with autoimmune diseases lack correlation with IL-33. T reg cell frequency, but not plasma IL-33 levels, represents potential immunological biomarker to predict clinical response to IVIG therapy.

  19. Chemically different non-thermal plasmas target distinct cell death pathways

    Czech Academy of Sciences Publication Activity Database

    Lunov, Oleg; Zablotskyy, Vitaliy A.; Churpita, Olexandr; Lunova, M.; Jirsa, M.; Dejneka, Alexandr; Kubinová, Šárka

    2017-01-01

    Roč. 7, č. 1 (2017), s. 1-17, č. článku 600. ISSN 2045-2322 Grant - others:AV ČR(CZ) Fellowship J. E. Purkyně Institutional support: RVO:68378271 Keywords : chemically different * non-thermal plasmas * target distinct cell death pathways Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 4.259, year: 2016

  20. Chiral Plasma Pharmacokinetics of 3,4-Methylenedioxymethamphetamine and its Phase I and II Metabolites following Controlled Administration to Humans.

    OpenAIRE

    Steuer Andrea E; Schmidhauser Corina; Schmid Yasmin; Rickli Anna; Liechti Matthias E; Kraemer Thomas

    2015-01-01

    Generally, pharmacokinetic studies on 3,4-methylenedioxymethamphetamine (MDMA) in blood have been performed after conjugate cleavage, without taking into account that phase II metabolites represent distinct chemical entities with their own effects and stereoselective pharmacokinetics. The aim of the present study was to stereoselectively investigate the pharmacokinetics of intact glucuronide and sulfate metabolites of MDMA in blood plasma after a controlled single MDMA dose. Plasma samples fr...

  1. Measurement of apolipoprotein B radioactivity in whole blood plasma by precipitation with isopropanol

    International Nuclear Information System (INIS)

    Yamada, N.; Havel, R.J.

    1986-01-01

    A method to measure apolipoprotein B radioactivity in whole blood plasma is described that is suitable for routine use in kinetic experiments in vivo. Radiolabeled apolipoprotein B is precipitated from plasma diluted 15- to 30-fold in the presence of carrier low density lipoproteins by 50% isopropanol. The amount of radioiodine in apoB is estimated from the difference between total radioiodine concentration in whole plasma and the fraction soluble in 50% isopropanol. Addition of up to 100 microliters of plasma to radioiodinated lipoproteins did not alter the percent of radioiodine precipitated in 1500 microliters of 50% isopropanol. The percent of radioiodine precipitated by isopropanol 3 min after intravenous injection of homologous radioiodinated very low density lipoproteins, intermediate density lipoproteins, and low density lipoproteins into rabbits was almost identical to that in the injected lipoproteins (y = 1.009 X +/- 0.462; r = 0.997)

  2. The relationship between chemical structure and dielectric properties of plasma-enhanced chemical vapor deposited polymer thin films

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Hao [Materials Sci and Tech Applications, LLC, 409 Maple Springs Drive, Dayton OH 45458 (United States)]. E-mail: hao.jiang@wpafb.af.mil; Hong Lianggou [Materials Sci and Tech Applications, LLC, 409 Maple Springs Drive, Dayton OH 45458 (United States); Venkatasubramanian, N. [Research Institute, University of Dayton, 300 College Park, Dayton, OH 45469-0168 (United States); Grant, John T. [Research Institute, University of Dayton, 300 College Park, Dayton, OH 45469-0168 (United States); Eyink, Kurt [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States); Wiacek, Kevin [Air Force Research Laboratory, Propulsion Directorate, 1950 Fifth Street, Wright-Patterson Air Force Base, OH 45433-7251 (United States); Fries-Carr, Sandra [Air Force Research Laboratory, Propulsion Directorate, 1950 Fifth Street, Wright-Patterson Air Force Base, OH 45433-7251 (United States); Enlow, Jesse [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States); Bunning, Timothy J. [Air Force Research Laboratory, Materials Directorate, 3005 Hobson Way, Wright-Patterson Air Force Base, OH 45433-7707 (United States)

    2007-02-26

    Polymer dielectric films fabricated by plasma enhanced chemical vapor deposition (PECVD) have unique properties due to their dense crosslinked bulk structure. These spatially uniform films exhibit good adhesion to a variety of substrates, excellent chemical inertness, high thermal resistance, and are formed from an inexpensive, solvent-free, room temperature process. In this work, we studied the dielectric properties of plasma polymerized (PP) carbon-based polymer thin films prepared from two precursors, benzene and octafluorocyclobutane. Two different monomer feed locations, directly in the plasma zone or in the downstream region (DS) and two different pressures, 80 Pa (high pressure) or 6.7 Pa (low pressure), were used. The chemical structure of the PECVD films was examined by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. The dielectric constant ({epsilon} {sub r}) and dielectric loss (tan {delta}) of the films were investigated over a range of frequencies up to 1 MHz and the dielectric strength (breakdown voltage) (F {sub b}) was characterized by the current-voltage method. Spectroscopic ellipsometry was performed to determine the film thickness and refractive index. Good dielectric properties were exhibited, as PP-benzene films formed in the high pressure, DS region showed a F{sub b} of 610 V/{mu}m, an {epsilon} {sub r} of 3.07, and a tan {delta} of 7.0 x 10{sup -3} at 1 kHz. The PECVD processing pressure has a significant effect on final film structure and the film's physical density has a strong impact on dielectric breakdown strength. Also noted was that the residual oxygen content in the PP-benzene films significantly affected the frequency dependences of the dielectric constant and loss.

  3. The relationship between chemical structure and dielectric properties of plasma-enhanced chemical vapor deposited polymer thin films

    International Nuclear Information System (INIS)

    Jiang Hao; Hong Lianggou; Venkatasubramanian, N.; Grant, John T.; Eyink, Kurt; Wiacek, Kevin; Fries-Carr, Sandra; Enlow, Jesse; Bunning, Timothy J.

    2007-01-01

    Polymer dielectric films fabricated by plasma enhanced chemical vapor deposition (PECVD) have unique properties due to their dense crosslinked bulk structure. These spatially uniform films exhibit good adhesion to a variety of substrates, excellent chemical inertness, high thermal resistance, and are formed from an inexpensive, solvent-free, room temperature process. In this work, we studied the dielectric properties of plasma polymerized (PP) carbon-based polymer thin films prepared from two precursors, benzene and octafluorocyclobutane. Two different monomer feed locations, directly in the plasma zone or in the downstream region (DS) and two different pressures, 80 Pa (high pressure) or 6.7 Pa (low pressure), were used. The chemical structure of the PECVD films was examined by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. The dielectric constant (ε r ) and dielectric loss (tan δ) of the films were investigated over a range of frequencies up to 1 MHz and the dielectric strength (breakdown voltage) (F b ) was characterized by the current-voltage method. Spectroscopic ellipsometry was performed to determine the film thickness and refractive index. Good dielectric properties were exhibited, as PP-benzene films formed in the high pressure, DS region showed a F b of 610 V/μm, an ε r of 3.07, and a tan δ of 7.0 x 10 -3 at 1 kHz. The PECVD processing pressure has a significant effect on final film structure and the film's physical density has a strong impact on dielectric breakdown strength. Also noted was that the residual oxygen content in the PP-benzene films significantly affected the frequency dependences of the dielectric constant and loss

  4. Relationship of cytokine levels and clinical effect on platelet-rich plasma-treated lateral epicondylitis.

    Science.gov (United States)

    Lim, Wonbong; Park, Sang H; Kim, Bora; Kang, Sin W; Lee, Jung W; Moon, Young L

    2018-03-01

    Lateral epicondylitis (LE) is difficult to manage and can result in significant patient morbidity. Currently, the clinical use of platelet-rich plasma (PRP) for painful tendons has received attention, but its efficacy remains controversial. This study aimed to investigate the clinical effects of PRP and its biological components. A total of 156 patients with LE were randomly divided into group 1, treated with a single injection of 2-ml autologous PRP, and group 2, treated with a control received only physical therapy without injection. Both groups used a tennis elbow strap and performed stretching and strengthening exercises during 24 weeks' follow-up. Pain and functional improvements were assessed using the visual analog scale (VAS), Modified Mayo Clinic Performance Index for the elbow, and magnetic resonance imaging (MRI). White blood cell count, platelet count, and levels of platelet-derived growth factor-AB (PDGF-AB), PDGF-BB, transforming growth factor-β (TGF-β), vascular endothelial growth factor, epithelial growth factor, and interleukin-1 β in PRP were measured and investigated for statistical correlation with the clinical score. At 24 weeks, all pain and functional variables, including VAS score, Mayo Clinic performance scores, and MRI grade, improved significantly in group 1 (p < 0.05). PDGF-AB, PDGF-BB, and TGF-β levels were more significantly increased in PRP than in whole blood. TGF-β level significantly correlated with Mayo Clinic performance score and MRI grade improvement. Thus, TGF-β level in PRP is considered to play a pivotal role in tendon healing. These results may contribute to identifying the best protocol for PRP application in tendinopathies. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:913-920, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Prospect for application of umbilical cord blood to clinical treatment of radiation sickness

    International Nuclear Information System (INIS)

    Jia Tingzhen; Ke Xiaoyan

    1998-01-01

    Objective: To look forward to the prospect for application of umbilical cord blood to clinical treatment of radiation sickness by analyzing the results using umbilical cord blood in laboratory experiments and clinical research. Method: The data on umbilical cord blood published in literature are reviewed. Results: The umbilical blood is rich in hematopoietic stem/progenitor cells, low in immunological activity of lymphocytes, expanded significantly ex vivo under selected culture condition readily available and collected easily. Conclusion: With the above advantages, the prospect for application of umbilical cord blood is encouraging, particularly in the clinical treatment of radiation sickness

  6. A systematic review of the relationship between blood loss and clinical signs.

    Directory of Open Access Journals (Sweden)

    Rodolfo Carvalho Pacagnella

    Full Text Available INTRODUCTION: This systematic review examines the relationship between blood loss and clinical signs and explores its use to trigger clinical interventions in the management of obstetric haemorrhage. METHODS: A systematic review of the literature was carried out using a comprehensive search strategy to identify studies presenting data on the relationship of clinical signs & symptoms and blood loss. Methodological quality was assessed using the STROBE checklist and the general guidelines of MOOSE. RESULTS: 30 studies were included and five were performed in women with pregnancy-related haemorrhage (other studies were carried in non-obstetric populations. Heart rate (HR, systolic blood pressure (SBP and shock index were the parameters most frequently studied. An association between blood loss and HR changes was observed in 22 out of 24 studies, and between blood loss and SBP was observed in 17 out of 23 studies. An association was found in all papers reporting on the relationship of shock index and blood loss. Seven studies have used Receiver Operating Characteristic Curves to determine the accuracy of clinical signs in predicting blood loss. In those studies the AUC ranged from 0.56 to 0.74 for HR, from 0.56 to 0.79 for SBP and from 0.77 to 0.84 for shock index. In some studies, HR, SBP and shock index were associated with increased mortality. CONCLUSION: We found a substantial variability in the relationship between blood loss and clinical signs, making it difficult to establish specific cut-off points for clinical signs that could be used as triggers for clinical interventions. However, the shock index can be an accurate indicator of compensatory changes in the cardiovascular system due to blood loss. Considering that most of the evidence included in this systematic review is derived from studies in non-obstetric populations, further research on the use of the shock index in obstetric populations is needed.

  7. Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish.

    Science.gov (United States)

    Harrenstien, Lisa A; Tornquist, Susan J; Miller-Morgan, Timothy J; Fodness, Brian G; Clifford, Kevin E

    2005-01-15

    To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities. Prospective study. 41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses. Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.

  8. Clinical, haematological and biochemical responses of sheep undergoing autologous blood transfusion

    Directory of Open Access Journals (Sweden)

    Sousa Rejane

    2012-05-01

    Full Text Available Abstract Background This study aimed to evaluate the clinical, haematological and biochemical responses to autologous blood transfusion and the feasibility of this practice in sheep. Thus, we used eight male, 8 months old sheep, weighing on average 30 kg, from which 15 mL/kg of whole blood was collected and stored in CPDA-1 bags. Blood samples were refrigerated for 8 days and subsequently re-infused. The clinical, haematological and biochemical parameters were evaluated before blood collection and reinfusion, after 10 minutes of collection and reinfusion, after 3, 6, 12, 24, 48, 96 and 192 hours after collection and reinfusion. Results With respect to clinical parameters, we observed a decrease in heart rate after 24, 48 and 196 hours from reinfusion compared to basal values (p p p p  Conclusion Autologous transfusion in sheep slightly altered the physiological, biochemical and haematological responses of sheep, indicating that the technique proposed is safe and can be applied in the clinical practice of this species. The 8 d period was not sufficient for complete recovery of the haematological parameters after blood collection.

  9. Clovamide-rich extract from Trifolium pallidum reduces oxidative stress-induced damage to blood platelets and plasma.

    Science.gov (United States)

    Kolodziejczyk, Joanna; Olas, Beata; Wachowicz, Barbara; Szajwaj, Barbara; Stochmal, Anna; Oleszek, Wieslaw

    2011-09-01

    Numerous plants (including clovers) have been widely used in folk medicine for the treatment of different disorders. This in vitro study was designed to examine the antioxidative effects of the clovamide-rich fraction, obtained from aerial parts of Trifolium pallidum, in the protection of blood platelets and plasma against the nitrative and oxidative damage, caused by peroxynitrite (ONOO(-)). Carbonyl groups and 3-nitrotyrosine in blood platelet and plasma proteins were determined by ELISA tests. Thiol groups level was estimated by using 5,5'-dithio-bis(2-nitro-benzoic acid, DTNB). Plasma lipid peroxidation was measured spectrophotometrically as the production of thiobarbituric acid reactive substances. The results from our work indicate that clovamide-rich T. pallidum extract may reveal the protective properties in the prevention against oxidative stress. The presence of clovamide-rich T. pallidum extract (12.5-100 μg/ml) partly inhibited ONOO(-)-mediated protein carbonylation and nitration. All the used concentrations of T. pallidum extract reduced lipid peroxidation in plasma. The antioxidative action of the tested extract in the protection of blood platelet lipids was less effective; the extract at the lowest final concentration (12.5 μg/ml) had no protective effect against lipid peroxidation. The present results indicate that the extract from T. pallidum is likely to be a source of compounds with the antioxidative properties, useful in the prevention against the oxidative stress-related diseases.

  10. [Blood plasma volume dynamics in monkeys during immersion].

    Science.gov (United States)

    Krotov, V P; Burkovskaia, T E; Dotsenko, M A; Gordeev, Iu V; Nosovskiĭ, A M; Chel'naia, N A

    2004-01-01

    Dynamics of blood plasma volume (PV) was studied with indirect methods (hematocrit count, hemoglobin, total protein and high-molecular protein) during 9-d immersion of monkeys Macaca mulatta. The animals were donned in waterproof suits, motor restrained in space seat liners and immersed down to the xiphisternum. Two monkeys were immersed in the bath at one time. The suits were changed every day under ketamine (10 mg/kg of body mass). There were two groups with 12 animals in each. The first group was kept in the bath 3 days and the second--9 days. Prior to the experiment, the animals had been trained to stay in the seat liner put down into the dry bath. It was shown that already two days of exposure to the hydrostatic forces (approximately 15 mm Hg) and absence of negative pressure breathing reduced PV by 18-20% on the average in all animals. Subsequent PV dynamics was individual by character; however, PV deficit persisted during 4 days of immersion in the whole group. In this period, albumin filtration was increased significantly, whereas high-molecular protein filtration was increased to a less degree. During the remaining days in immersion PV regained normal values. Ten days of readaptation (reclined positioning of monkeys brought back into cage) raised VP beyond baseline values. This phenomenon can be attributed to the necessity to provide appropriate venous return and sufficient blood supply of organs and tissues following extension of blood vessels capacity.

  11. Hormones and endocrine disruptors in human seminal plasma.

    Science.gov (United States)

    Hampl, R; Kubatova, J; Heracek, J; Sobotka, V; Starka, L

    2013-07-01

    Seminal plasma represents a unique environment for maturation, nutrition, and protection of male germ cells from damaging agents. It contains an array of organic as well as inorganic chemicals, encompassing a number of biologically and immunologically active compounds, including hormones. Seminal plasma contains also various pollutants transferred from outer environment known as endocrine disruptors. They interfere with hormones at the receptor level, act as inhibitors of their biosynthesis, and affect hormone regulation.In this minireview, the main groups of hormones detected in seminal plasma are summarized. Seminal gonadal steroids were investigated mostly with aim to use them as biomarkers of impaired spermatogenesis (sperm count, motility, morphology). Concentrations of hormones in the seminal plasma often differ considerably from the blood plasma levels in dependence on their origin. In some instances (dihydrotestosterone, estradiol), their informative value is higher than determination in blood.Out of peptide hormones detected in seminal plasma, peptides of transforming growth factor beta family, especially antimullerian hormone, and oligopeptides related to thyrotropin releasing hormone have the high informative value, while assessment of seminal gonadotropins and prolactin does not bring advantage over determination in blood.Though there is a large body of information about the endocrine disruptors' impact on male reproduction, especially with their potential role in decline of male reproductive functions within the last decades, there are only scarce reports on their presence in seminal plasma. Herein, the main groups of endocrine disruptors found in seminal plasma are reviewed, and the use of their determination for investigation of fertility disorders is discussed.

  12. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  13. Hematologic and plasma biochemical reference values in Indian peafowl (Pavo cristatus).

    Science.gov (United States)

    Samour, Jaime; Naldo, Jesus; Rahman, Habeeb; Sakkir, Mohammed

    2010-06-01

    Blood samples were collected from captive, adult, clinically normal Indian peafowl (Pavo cristatus) for hematologic and plasma biochemical analyses. Hematologic parameters investigated were total red blood cell count, hemoglobin, packed cell volume, fibrinogen, mean cell volume, mean cell hemoglobin, mean cell hemoglobin concentration, total white blood cell count, differential white blood cell count, and thrombocyte count. Plasma biochemical parameters investigated were alanine aminotransferase, alkaline phosphatase, amylase, aspartate aminotransferase, bile acids, total bilirubin, blood urea nitrogen, calcium, cholesterol, creatinine, creatine kinase, gamma glutamyltransferase, lactate dehydrogenase, glucose, iron, phosphorus, and uric acid, as well as plasma protein electrophoresis. Results were compared with values from studies done in houbara bustards (Chlamydotis undulata), kori bustards (Ardeotis kori), stone curlews (Burhinus oedicnemus), and taxonomically related species, including ring-necked pheasants (Phasianus colchicus), red-legged partridges (Alectoris rufa), Kashmir native fowl (Kashmirfavorella), and Bangladesh native, Fayoumi, and Assil fowl (Gallus domesticus).

  14. Validation and clinical application of a method to quantify nevirapine in dried blood spots and dried breast-milk spots.

    Science.gov (United States)

    Olagunju, Adeniyi; Amara, Alieu; Waitt, Catriona; Else, Laura; Penchala, Sujan D; Bolaji, Oluseye; Soyinka, Julius; Siccardi, Marco; Back, David; Owen, Andrew; Khoo, Saye

    2015-10-01

    The validation and clinical application of an LC-MS/MS method for the quantification of nevirapine in dried blood spots (DBS) and dried breast-milk spots (DBMS) are presented. DBS and DBMS were prepared from 50 and 30 μL of nevirapine-spiked whole blood and human breast milk, respectively. Chromatographic separation was achieved on a reverse-phase C18 column with 0.1% formic acid in water/acetonitrile using a solvent gradient programme at a flow rate of 400 μL/min, and detection was by a TSQ Quantum Access triple quadrupole mass spectrometer. The clinical application was evaluated in HIV-positive nursing mothers and their breastfed infants. The assay was validated over the concentration range 50-10,000 ng/mL. Accuracy ranged from 93.3% to 113.4% and precision ranged from 1.9% to 12.0%. The mean (percentage coefficient of variation) recovery of nevirapine from DBS and DBMS was ≥ 70.7% (≤ 8.2) and the matrix effect was ≤ 1.04 (≤ 6.1). Nevirapine was stable in DBS and DBMS for ≥ 15 months at room temperature and -80°C. Mean (SD) AUC0-12, Cmax and Cmin in maternal plasma versus breast milk were 57,808 ng · h/mL (24,315) versus 55,817 ng · h/mL (22,368), 6140 ng/mL (2605) versus 5231 ng/mL (2215) and 4334 ng/mL (1880) versus 4342 ng/mL (2245), respectively. The milk-to-plasma concentration ratio over the dosing interval was 0.94 (0.15). Infant plasma concentrations 2 and 8 h after maternal dosing were 580.6 ng/mL (464.7-1607) and 584.1 ng/mL (381.5-1570), respectively. These methods further extend opportunities for conducting clinical pharmacokinetic studies in nursing mother-infant pairs, especially in resource-limited settings. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. Safety evaluation of phytosterols in laying hens: effects on laying performance, clinical blood parameters, and organ development.

    Science.gov (United States)

    Shi, S R; Shen, Y R; Chang, L L; Zhou, C J; Bo, Z; Wang, Z Y; Tong, H B; Zou, J M

    2014-03-01

    Phytosterols are intended for use as a novel food ingredient with plasma cholesterol-lowering activity. Although phytosterols are naturally present in the normal diet, daily consumption is insufficient to ensure plasma cholesterol-lowering levels. Therefore, phytosterols may be added to the diets to achieve the desired cholesterol-lowering activity. A subchronic laying hen safety study was conducted to examine if high-dose phytosterols could affect the safety of hens. Three hundred sixty 21-wk-old Hy-Line Brown laying hens were randomly assigned to 5 groups with 6 replicates of 12 birds each; after 3 wk, birds were fed diets supplemented with 0, 20, 80, 400, and 800 mg/kg of phytosterols for 12 wk. Throughout the study, clinical observations and laying performance were measured. At the end of the study, birds were subjected to a full postmortem examination: blood samples were taken for clinical pathology, selected organs were weighed, and specified tissues were taken for subsequent histological examination. No treatment-related changes that were considered to be of toxicological significance were observed. Therefore, a nominal phytosterol concentration of 800 mg/kg was considered to be the no-observed-adverse-effect level.

  16. Amperometric Sensor for Heparin: Sensing Mechanism and Application in Human Blood Plasma Analysis

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Olšák, J.; Samcová, E.; Samec, Zdeněk; Trojánek, Antonín

    2006-01-01

    Roč. 18, 13-14 (2006), s. 1329-1338 ISSN 1040-0397 R&D Projects: GA ČR GA203/04/0424 Institutional research plan: CEZ:AV0Z40400503 Keywords : heparin * amperometry * PVC membrane electrode * sensing mechanism * human blood plasma Subject RIV: CG - Electrochemistry Impact factor: 2.444, year: 2006

  17. Study on the correlative analysis between the changes of immunofunction status of peripheral blood red blood cells and plasma thromboxane B2 (TXB2) level in patients with pregnancy induced hypertension (PIH)

    International Nuclear Information System (INIS)

    Liu Ailing; Zhou Dongxia; Wang Yuanyuan

    2011-01-01

    Objective: To explore the relationship between changes of immunofuction status of peripheral blood red blood cells and plasma thromboxane B 2 (TXB 2 ) level in patients with PIH. Methods: RBC immunofunction status was studied with immunologic methods and plasma TXB 2 Level was measured with RIA in 33 patients with PIH and 35 normal controls.Results Level of RBC-C3bRR was significantly lower and level of plasma TXB 2 was markedly higher in the patients than those in controls (P 2 (r=0.4084, P 2 levels in patients with PIH. (authors)

  18. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  19. Effects of chemical sympathectomy on the increases in plasma catecholamines and dopamine-beta-hydroxylase induced by forced immobilization and insulin-induced hypoglycemia: origin and fate of plasma dopamine-beta-hydroxylase.

    Science.gov (United States)

    Israel, A S; Barbella, Y R; Cubeddu, L X

    1982-06-01

    The effect of acute stresses on plasma norepinephrine, epinephrine and dopamine-beta-hydroxylase (DBH) were evaluated in control and 6-hydroxydopamine-treated, awake cannulated guinea pigs. Forced immobolization for 1 hr caused a 3- and 5-fold increase in plasma DBH and norepinephrine, respectively. Pretreatment with 6-hydroxydopamine (23 mg/kg b.wt.i.a., 72 and 48 hr before stress) reduced by 70% the increase in plasma DBH and totally prevented the rise in plasma catecholamines evoked by the restraining stress. Injection of insulin (5 U/kg b.wt.i.a.) induced a 60% decrease in blood glucose, a 1-fold increase in plasma DBH and a selective 4-fold increase in plasma epinephrine; these effects were not modified by chemical sympathectomy. Our results indicate that forced immobilization and hypoglycemia produce a preferential activation of the sympathetic postganglionic nerves and of the adrenal medulla, respectively, and that in guinea pigs both stresses increase plasma DBH. The kinetics of disappearance of plasma DBH were studied after subjecting the guinea pigs for 1 hr to forced immobilization. Although 7 of 12 animals showed a biphasic rate of fall of plasma DBH, in each case there was a rapid initial fall possibly due to the "distribution" of the enzyme with a T1/2 of 1.65 hr. Similar findings were observed in 6-hydroxydopamine-treated guinea pigs. These results suggest that the distribution of DBH is the most important process in reducing the augmented plasma DBH levels elicited by a short-term stress and that this process is not dependent on the integrity of the sympathetic nerves nor on the adrenal or sympathetic origin of the enzyme. This study supports the view that the ratio, content of releasable DBH present in sympathetic nerves and adrenal glands/total circulating pool of DBH, is the factor that determines whether an increase in plasma DBH would occur in animals exposed to an acute stress.

  20. Clinical significance of determination of changes of plasma ET-1 and CGRP contents in elderly males with metabolic syndrome

    International Nuclear Information System (INIS)

    Sun Xiaoming; Luo Nanping; Bai Lu; Wang Xueping

    2005-01-01

    Objective: To investigate the significance of changes of plasma endothelin-1 (ET-1) and calcitonin gene related peptide (CGRP) contents in elderly males with metabolic syndrome. Methods: Plasma ET-1 and CGRP contents were measured with RIA in 65 elderly males with hypertension and 65 elderly males with diabetes. The blood lipid and sugar contents were measured simultaneously. 35 controls entered this study. Results: The plasma ET-1 contents in elderly males with simple hypertension, diabetes and metabolic syndrome were all significantly higher than those in controls (P<0.01, P<0.05, P<0.05). Levels in hypertensives were significantly higher than those in diabetics (P<0.05). The plasma CGRP levels in the elderly males with hypertension and with metabolic syndrome were all significantly lower than those in controls (P<0.05, P<0.05). The CGRP levels in these subjects were significantly negatively correlated with the ET-1 levels (r= -0.75, P<0.01; r=-0.53, P<0.01). Conclusion: Changes of plasma ET-1 and CGRP levels in elderly males with metabolic syndrome were clinically significant, especially in the pathogenesis of hypertension. (authors)

  1. Plasma Vitamin E and Blood Selenium Concentrations in Norwegian Dairy Cows: Regional Differences and Relations to Feeding and Health

    Directory of Open Access Journals (Sweden)

    Østerås O

    2005-12-01

    Full Text Available Plasma α-tocopherol (vit E and blood selenium (Se concentrations in February were determined in samples from 314 dairy cows in Norway, selected to provide a representative subset of the Norwegian dairy cow population. Each sample was followed by a questionnaire with information about feeding of the cow at the time of sampling. The results were correlated to herd data and to calving and health data for each cow from the Norwegian Dairy Herd Recording System and the Norwegian Cattle Health Recording System. The mean concentrations were 6.9 μg vit E per ml plasma and 0.16 μg Se per g blood. Both levels were highest in mid lactation. Plasma vit E varied with the amount of silage fed to the cow, while blood Se varied with the amount of concentrates and mineral supplements, and with geographical region. No differences in vit E or Se levels were found between cows with recorded treatments for mastitis, parturient paresis or reproductive disorders in the lactation during or immediately prior to sampling, and those without such treatments. For ketosis, a small difference in blood Se was found between the groups with or without recorded treatments. It is concluded that winter-fed lactating cows in Norway had an adequate plasma level of vit E and a marginal-to-adequate level of Se.

  2. Plasma Vitamin E and Blood Selenium Concentrations in Norwegian Dairy Cows: Regional Differences and Relations to Feeding and Health

    Directory of Open Access Journals (Sweden)

    Sivertsen T

    2006-12-01

    Full Text Available Plasma α-tocopherol (vit E and blood selenium (Se concentrations in February were determined in samples from 314 dairy cows in Norway, selected to provide a representative subset of the Norwegian dairy cow population. Each sample was followed by a questionnaire with information about feeding of the cow at the time of sampling. The results were correlated to herd data and to calving and health data for each cow from the Norwegian Dairy Herd Recording System and the Norwegian Cattle Health Recording System. The mean concentrations were 6.9 μg vit E per ml plasma and 0.16 μg Se per g blood. Both levels were highest in mid lactation. Plasma vit E varied with the amount of silage fed to the cow, while blood Se varied with the amount of concentrates and mineral supplements, and with geographical region. No differences in vit E or Se levels were found between cows with recorded treatments for mastitis, parturient paresis or reproductive disorders in the lactation during or immediately prior to sampling, and those without such treatments. For ketosis, a small difference in blood Se was found between the groups with or without recorded treatments. It is concluded that winter-fed lactating cows in Norway had an adequate plasma level of vit E and a marginal-to-adequate level of Se.

  3. Hierarchical clustering analysis of blood plasma lipidomics profiles from mono- and dizygotic twin families

    NARCIS (Netherlands)

    Draisma, H.H.; Reijmers, T.H.; Meulman, J.J.; Greef, J. van der; Hankemeier, T.; Boomsma, D.I.

    2013-01-01

    Twin and family studies are typically used to elucidate the relative contribution of genetic and environmental variation to phenotypic variation. Here, we apply a quantitative genetic method based on hierarchical clustering, to blood plasma lipidomics data obtained in a healthy cohort consisting of

  4. Diode laser irradiation of rat blood and its effect on hemoglobin and plasma

    International Nuclear Information System (INIS)

    Saad-El-Din, A.A.; El-Ahdaal, M.A.; Omran, M.F.

    2002-01-01

    Blood was exposed to diode laser irradiation of wavelength 830 nm and maximum powe of 31.4 MW, with exposure times 15, 30, 45 and 60 minutes. Hemoglobin IR spectra and X-ray crystallography, plasma Na + , K + , Ca + +. cholesterol concentrations and viscosity were measured. There were changes in hemoglobin amide groups as well as changes in the X-ray in hemoglobin structure. Decreases in both Na concentration and plasma viscosity occurred at 15 and 30 minutes of laser exposure. On increasing time to 45 and 60 minutes, the Na concentration and viscosity were increased. K, Ca and cholesterol concentration were decreased linearly with time. Na / K ratio was increased also with time of exposure. The results have been indicated that the diode laser affect the secondary structure of hemoglobin, membranes structures and plasma

  5. [Blood plasma protein adsorption capacity of perfluorocarbon emulsion stabilized by proxanol 268 (in vitro and in vivo studies)].

    Science.gov (United States)

    Sklifas, A N; Zhalimov, V K; Temnov, A A; Kukushkin, N I

    2012-01-01

    The adsorption abilities of the perfluorocarbon emulsion stabilized by Proxanol 268 were investigated in vitro and in vivo. In vitro, the saturation point for the blood plasma proteins was nearly reached after five minutes of incubation of the emulsion with human/rabbit blood plasma and was stable for all incubation periods studied. The decrease in volume ratio (emulsion/plasma) was accompanied by the increase in the adsorptive capacity of the emulsion with maximal values at 1/10 (3.2 and 1.5 mg of proteins per 1 ml of the emulsion, for human and rabbit blood plasma, respectively) that was unchanged at lower ratios. In vivo, in rabbits, intravenously injected with the emulsion, the proteins with molecular masses of 12, 25, 32, 44, 55, 70, and 200 kDa were adsorbed by the emulsion (as in vitro) if it was used 6 hours or less before testing. More delayed testing (6 h) revealed elimination of proteins with molecular masses of 25 and 44 kDa and an additional pool of adsorpted new ones of 27, 50, and 150 kDa. Specific adsorptive capacity of the emulsion enhanced gradually after emulsion injection and reached its maximum (3.5-5 mg of proteins per 1 ml of the emulsion) after 24 hours.

  6. Predictive model accuracy in estimating last Δ9-tetrahydrocannabinol (THC) intake from plasma and whole blood cannabinoid concentrations in chronic, daily cannabis smokers administered subchronic oral THC.

    Science.gov (United States)

    Karschner, Erin L; Schwope, David M; Schwilke, Eugene W; Goodwin, Robert S; Kelly, Deanna L; Gorelick, David A; Huestis, Marilyn A

    2012-10-01

    Determining time since last cannabis/Δ9-tetrahydrocannabinol (THC) exposure is important in clinical, workplace, and forensic settings. Mathematical models calculating time of last exposure from whole blood concentrations typically employ a theoretical 0.5 whole blood-to-plasma (WB/P) ratio. No studies previously evaluated predictive models utilizing empirically-derived WB/P ratios, or whole blood cannabinoid pharmacokinetics after subchronic THC dosing. Ten male chronic, daily cannabis smokers received escalating around-the-clock oral THC (40-120 mg daily) for 8 days. Cannabinoids were quantified in whole blood and plasma by two-dimensional gas chromatography-mass spectrometry. Maximum whole blood THC occurred 3.0 h after the first oral THC dose and 103.5h (4.3 days) during multiple THC dosing. Median WB/P ratios were THC 0.63 (n=196), 11-hydroxy-THC 0.60 (n=189), and 11-nor-9-carboxy-THC (THCCOOH) 0.55 (n=200). Predictive models utilizing these WB/P ratios accurately estimated last cannabis exposure in 96% and 100% of specimens collected within 1-5h after a single oral THC dose and throughout multiple dosing, respectively. Models were only 60% and 12.5% accurate 12.5 and 22.5h after the last THC dose, respectively. Predictive models estimating time since last cannabis intake from whole blood and plasma cannabinoid concentrations were inaccurate during abstinence, but highly accurate during active THC dosing. THC redistribution from large cannabinoid body stores and high circulating THCCOOH concentrations create different pharmacokinetic profiles than those in less than daily cannabis smokers that were used to derive the models. Thus, the models do not accurately predict time of last THC intake in individuals consuming THC daily. Published by Elsevier Ireland Ltd.

  7. Effect of an extract of Artemisia vulgaris L. (Mugwort) on the in vitro labeling of red blood cells and plasma proteins with technetium-99m

    International Nuclear Information System (INIS)

    Terra, Danielle Amorim; Brandao-Neto, Jose; Medeiros, Aldo da Cunha; Amorim, Lucia de Fatima; Catanho, Maria Tereza Jansen de Almeida; Fonseca, Adenilson de Souza da; Santos-Filho, Sebastiao David; Bernardo-Filho, Mario

    2007-01-01

    The aim of this work was to evaluate the effect of an extract of the Artemisia vulgaris L. (mugwort) on the labeling of blood constituents with technetium-99m (99mTc). Blood samples from Wistar rats were incubated with a mugwort extract and the radiolabeling of blood constituents was carried out. Plasma and blood cells were separated by centrifugation. Aliquots of plasma and blood cells were also precipitated with trichloroacetic acid and centrifuged to isolate soluble and insoluble fractions of plasma and blood cells. Radioactivity in each fraction was counted and the percentages of radioactivity (%ATI) was calculated. Mugwort extract decreased significantly (p<0.05) the %ATI on the blood compartments and on the blood cells proteins (insoluble fraction). The analysis of the results indicates that the extract could have substances that could interfere on the transport of stannous through the erythrocyte membrane altering the labeling of blood cells with 99mTc. (author)

  8. 18F-FDG-labeled red blood cell PET for blood-pool imaging: preclinical evaluation in rats.

    Science.gov (United States)

    Matsusaka, Yohji; Nakahara, Tadaki; Takahashi, Kazuhiro; Iwabuchi, Yu; Nishime, Chiyoko; Kajimura, Mayumi; Jinzaki, Masahiro

    2017-12-01

    Red blood cells (RBCs) labeled with single-photon emitters have been clinically used for blood-pool imaging. Although some PET tracers have been introduced for blood-pool imaging, they have not yet been widely used. The present study investigated the feasibility of labeling RBCs with 18 F-2-deoxy-2-fluoro-D-glucose ( 18 F-FDG) for blood-pool imaging with PET. RBCs isolated from venous blood of rats were washed with glucose-free phosphate-buffered saline and labeled with 18 F-FDG. To optimize labeling efficiency, the effects of glucose deprivation time and incubation (labeling) time with 18 F-FDG were investigated. Post-labeling stability was assessed by calculating the release fraction of radioactivity and identifying the chemical forms of 18 F in the released and intracellular components of 18 F-FDG-labeled RBCs incubated in plasma. Just after intravenous injection of the optimized autologous 18 F-FDG-labeled RBCs, dynamic PET scans were performed to evaluate in vivo imaging in normal rats and intraabdominal bleeding models (temporary and persistent bleeding). The optimal durations of glucose deprivation and incubation (labeling) with 18 F-FDG were 60 and 30 min, respectively. As low as 10% of 18 F was released as the form of 18 F-FDG from 18 F-FDG-labeled RBCs after a 60-min incubation. Dynamic PET images of normal rats showed strong persistence in the cardiovascular system for at least 120 min. In the intraabdominal bleeding models, 18 F-FDG-labeled RBC PET visualized the extravascular blood clearly and revealed the dynamic changes of the extravascular radioactivity in the temporary and persistent bleeding. RBCs can be effectively labeled with 18 F-FDG and used for blood-pool imaging with PET in rats.

  9. Plasma selenium levels in healthy blood bank donors in the central-eastern part of Belgium.

    Science.gov (United States)

    Van Cauwenbergh, Rudy; Robberecht, Harry; Van Vlaslaer, Veerle; De Smet, Annie; Emonds, Marie-Paule; Hermans, Nina

    2007-01-01

    Graphite furnace atomic absorption spectrometry, with Zeeman background correction and after improved matrix modification, was used to measure the plasma selenium content of healthy blood bank donors in the central part of Belgium. The mean plasma selenium concentration of 80 men and 80 women was 79.7+/-4.4ng/mL with a range of 55.0-117.4ng/mL. There was no gender difference observed. Plasma selenium level was significantly highest for the adult group, aged 45-64 years, compared to the others, except the young adults (18-24 years). The mean plasma selenium concentration measured corresponded well with literature data for Belgium. The obtained values were found to be in the medium range, compared with recent literature values for the European countries.

  10. Hydrogen plasma enhanced alignment on CNT-STM tips grown by liquid catalyst-assisted microwave plasma-enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Tung, Fa-Kuei; Yoshimura, Masamichi; Ueda, Kazuyuki; Ohira, Yutaka; Tanji, Takayoshi

    2008-01-01

    Carbon nanotubes are grown directly on a scanning tunneling microscopy tip by liquid catalyst-assisted microwave-enhanced chemical vapor deposition, and effects of hydrogen plasma treatment on the tip have been investigated in detail by field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM) and Raman spectroscopy. The unaligned CNTs on the as-grown tip apex have been realigned and reshaped by subsequent hydrogen plasma treatment. The diameter of CNTs is enlarged mainly due to amorphous layers being re-sputtered over their outer shells

  11. Blood Glucose Determination

    DEFF Research Database (Denmark)

    Lippi, Giuseppe; Nybo, Mads; Cadamuro, Janne

    2018-01-01

    The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium...

  12. The clinical utility of ambulatory blood pressure monitoring (ABPM): a review.

    Science.gov (United States)

    Harianto, Harry; Valente, Michael; Hoetomo, Soenarno; Anpalahan, Mahesan

    2014-01-01

    The current evidence suggests that ambulatory blood pressure monitoring (ABPM) should be an integral part of the diagnosis and management of hypertension. However, its uptake in routine clinical practice has been variable. This paper reviews the current evidence for the role of ABPM in clinical practice, including in hypotensive disorders and in specific comorbidities. It further discusses the clinical significance of abnormal ambulatory blood pressure patterns and hypertensive syndromes such as white coat, masked and resistant hypertension.

  13. State-of-the-art technocology in blood purification at present

    Directory of Open Access Journals (Sweden)

    Zhi-hong LIU

    2011-02-01

    Full Text Available Objective To review the recent advancement in clinical practices and studies on blood purification techniques,and to provide a guide for further studies on its application in military medicine.Methods Literature published in recent five years limited to blood purification field either in English or Chinese were retrieved by searching PubMed and CHKD.Analysis and summary were performed based on the literature.Results The advancements in blood purification in recent five years could be categorized into four fields,i.e.hemodialysis(HD,peritoneal dialysis(PD,continuous renal replacement therapy(CRRT,and adsorption therapy.The development in HD was aimed at promoting the ability of removal of toxic elements producing uremia and online monitor techniques,and PD was aimed at improvement of patients’ general condition and intervention to reduce the risk factors affecting long-term outcomes,and preparation of new PD solutions to improve the efficacy of PD.In regard to CRRT,the current progress had been focused on initiation time,dose and proposal of new hypothesis for high-volume hemofiltration(HVHF application.Adsorption therapy was another choice of blood purification.Domestic military medicine progress in blood purification in our armed forces was focused on techniques that could be used in treatment of casualties in war,including the basic and clinical study of extracorporeal circuit intervention(ECI for treatment of critically ill patients,problems arising from anticoagulation in ECI for patients with trauma,chemical agents poisoning,and adsorption technique.Conclusions Recently,the main advancement of blood purification technique is combined application of series techniques such as dialysis,hemofiltration,adsorption,and plasma exchange in treatment of critically ill patients.Studies on blood purification in domestic military medicine should be updated continuously to follow closely to the latest achievement in world,and translate these latest

  14. Features of the Clinical Course of Adrenal Incidentalomas

    Directory of Open Access Journals (Sweden)

    G.A. Alimukhamedova

    2014-03-01

    Full Text Available The objective of the study was to examine the clinical features of adrenal incidentalomas. 98 clinical observations of patients with adrenal incidentalomas receiving in- and out-patient treatment in the clinic of Republican Specialized Scientific and Practical Medical Centre of Endocrinology of Ministry of Healthcare of Republic of Uzbekistan were analyzed. Of them, 51 % — males, 49 % — females. General clinical observation included: thorough gaining of complaints; anamnesis morbi and vitae; assessment of somatic and endocrine statuses; clinical examination with measurement of blood pressure and body mass index; urinalysis; biochemical blood analysis. In addition, all patients underwent complete blood count with determination of blood potassium, sodium, chlorine, lipid profile, fasting blood glucose and oral glucose tolerance test, creatinine and urea; hormonal blood tests, including studies of plasma aldosterone and plasma renin activity in a horizontal position, adrenocorticotropic hormone, blood cortisol, as well as the daily excretion of catecholamines with urine. For topical diagnosis we used ultrasound, CT of adrenals. It was found that adrenal incidentalomas were detected in 37.8 % as a result of searching for the reason of arterial hypertension, in 23.5 % — of obesity and hypothalamus dysfunction, in 14.2 % — in abdominal pathology, in 12.2 % — of non-specific complaints, in 8.1 % — in exclusion of adrenal diseases, and in 4 % — in clinical supervision. Clinically they are characterized with nonspecific features with predominance of arterial hypertension (76.5 %, which is associated with adrenal pathology only 18.4 % of cases. Analysis of metabolic disorders revealed clinically significant changes as well. Of 98 examined patients, 70 % had metabolic disorders.

  15. Comparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris).

    Science.gov (United States)

    Harr, Kendal E; Allison, Kathryn; Bonde, Robert K; Murphy, David; Harvey, John W

    2008-06-01

    Muscle injury is common in Florida manatees (Trichechus manatus latirostris). Plasma aspartate aminotransferase (AST) is frequently used to assess muscular damage in capture myopathy and traumatic injury. Therefore, accurate measurement of AST and alanine aminotransferase (ALT) is important in managed, free-ranging animals, as well as in those rehabilitating from injury. Activities of these enzymes, however, are usually not increased in manatees with either acute or chronic muscle damage, despite marked increases in plasma creatine kinase activity. It is hypothesized that this absence of response is due to apoenzymes in the blood not detected by commonly used veterinary assays. Addition of coenzyme pyridoxal-5-phosphate (P5P or vitamin B6) should, therefore, result in higher measured enzyme activities. The objective of this study was to determine the most accurate, precise, and diagnostically useful method for aminotransferase measurement in manatees that can be used in veterinary practices and diagnostic laboratories. Additionally, appropriate collection and storage techniques were assessed. The use of an optimized commercial wet chemical assay with 100 micromol P5P resulted in a positive bias of measured enzyme activities in a healthy population of animals. However, AST and ALT were still much lower than that typically observed in domestic animals and should not be used alone in the assessment of capture myopathy and muscular trauma. Additionally, the dry chemistry analyzer, typically used in clinics, reported significantly higher and less precise AST and ALT activities with poor correlation to those measured with wet chemical methods found in diagnostic laboratories. Therefore, these results cannot be clinically compared. Overall, the optimized wet chemical method was the most precise and diagnostically useful measurement of aminotransferase in samples. Additionally, there was a statistically significant difference between paired serum and plasma measurement

  16. Effect of disodium cromoglycate (DSCG) and antihistamines on postirradiation cerebral blood flow and plasma levels of histamine and neurotensin

    International Nuclear Information System (INIS)

    Cockerham, L.G.; Pautler, E.L.; Carraway, R.E.; Cochrane, D.E.; Hampton, J.D.

    1988-01-01

    In an attempt to elucidate mechanisms underlying the irradiation-induced decrease in regional cerebral blood flow (rCBF) in primates, hippocampal and visual cortical blood flows of rhesus monkeys were measured by hydrogen clearance, before and after exposure to 100 Gy, whole-body, gamma irradiation. Systemic blood pressures were monitored simultaneously. Systemic arterial plasma histamine and neurotensin levels were determined preirradiation and postirradiation. Compared to control animals, the irradiated monkeys exhibited an abrupt decline in systemic blood pressure to 23% of the preirradiation level within 10 min postirradiation, falling to 12% by 60 min. A decrease in hippocampal blood flow to 32% of the preirradiation level was noted at 10 min postirradiation, followed by a slight recovery to 43% at 30 min and a decline to 23% by 60 min. The cortical blood flow for the same animals showed a steady decrease to 29% of the preirradiation levels by 60 min postirradiation. Animals given the mast cell stabilizer disodium cromoglycate and the antihistamines mepyramine and cimetidine before irradiation did not exhibit an abrupt decline in blood pressure but displayed a gradual decrease to a level 33% below preirradiation levels by 60 min postirradiation. Also, the treated, irradiated monkeys displayed rCBF values that were not significantly different from the nonirradiated controls. The plasma neurotensin levels in the irradiated animals, treated and untreated, indicated a nonsignificant postirradiation increase above control levels. However, the postirradiation plasma histamine levels in both irradiated groups showed an increase of approximately 1600% above the preirradiation levels and the postirradiation control levels

  17. Sensing signatures mediated by chemical structure of molecular solids in laser-induced plasmas.

    Science.gov (United States)

    Serrano, Jorge; Moros, Javier; Laserna, J Javier

    2015-03-03

    Laser ablation of organic compounds has been investigated for almost 30 years now, either in the framework of pulse laser deposition for the assembling of new materials or in the context of chemical sensing. Various monitoring techniques such as atomic and molecular fluorescence, time-of-flight mass spectrometry, and optical emission spectroscopy have been used for plasma diagnostics in an attempt to understand the spectral signature and potential origin of gas-phase ions and fragments from organic plasmas. Photochemical and photophysical processes occurring within these systems are generally much more complex than those suggested by observation of optical emission features. Together with laser ablation parameters, the structural and chemical-physical properties of molecules seem to be closely tied to the observed phenomena. The present manuscript, for the first time, discusses the role of molecular structure in the optical emission of organic plasmas. Factors altering the electronic distribution within the organic molecule have been found to have a direct impact on its ensuing optical emissions. The electron structure of an organic molecule, resulting from the presence, nature, and position of its atoms, governs the breakage of the molecule and, as a result, determines the extent of atomization and fragmentation that has proved to directly impact the emissions of CN radicals and C2 dimers. Particular properties of the molecule respond more positively depending on the laser irradiation wavelength, thereby redirecting the ablation process through photochemical or photothermal decomposition pathways. It is of paramount significance for chemical identification purposes how, despite the large energy stored and dissipated by the plasma and the considerable number of transient species formed, the emissions observed never lose sight of the original molecule.

  18. Blood and Blood Components: From Similarities to Differences

    Directory of Open Access Journals (Sweden)

    Olivier Garraud

    2018-04-01

    Full Text Available Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025, many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations of blood transfusion diversity and the consequences for donors, patients, and society.

  19. Blood and Blood Components: From Similarities to Differences

    Science.gov (United States)

    Garraud, Olivier; Tissot, Jean-Daniel

    2018-01-01

    Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation) either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025), many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations) of blood transfusion diversity and the consequences for donors, patients, and society. PMID:29686986

  20. Content of non-esterified fatty acids in the blood plasma of rabbits with acute arginine pancreatitis and its correction

    Directory of Open Access Journals (Sweden)

    Y. F. Rivis

    2013-01-01

    Full Text Available The aim of this work was to study the content of non-esterified fatty acids in plasma and liver of rabbits with acute arginine pancreatitis and its correction by linseed oil. The experiment was carried out on male rabbits breed gray giant with live weight 3.8–4.0 kg. The material for the study was sampled from blood and liver. Lipids from plasma and liver were extracted with a mixture of chloroform and methanol. After that the non-esterified fatty acids were isolated and methylated. Methyl esters of fatty acids were studied by the gas-liquid chromatography with the chromatograph ''Chrom 5'' (Prague,CzechRepublic. We have found that the content of non-esterified fatty acids decreases in the blood plasma and liver of rabbits with the acute arginine pancreatitis. It takes place at the expense of a reduce of saturated fatty acids with odd and even number of carbon atoms in a chain, monounsaturated fatty acids of the families ω-7 and ω-9 and polyunsaturated fatty acids of the families ω-3 and ω-6. That may indicate a greater use of non-esterified fatty acids for energy metabolism and esterification of lipids. We suppose that this is a consequence of the probable increase in content of non-esterified and esterified cholesterol in the rabbits’ blood plasma. Those processes provoke the cholesterol deposits in blood vessels and therefore cardiovascular diseases. We tried to influence on the processes by addition of linseed oil to the rabbits diet. We have found that in the linseed oil-fed rabbits the content of non-esterified fatty acids decreases at the expense of saturated fatty acids with odd and even number of carbon atoms in a chain and monounsaturated fatty acids of the families ω-7 and ω-9 inblood plasma and liver of the rabbits with acute arginine pancreatitis. Furthermore the levels of non-esterified polyunsaturated fatty acids of ω-3 family increase in the rabbits’ plasma and liver. As this takes place the ratio of non

  1. Alpha-synuclein levels in blood plasma decline with healthy aging.

    Directory of Open Access Journals (Sweden)

    Niklas K U Koehler

    Full Text Available There is unequivocal evidence that alpha-synuclein plays a pivotal pathophysiological role in neurodegenerative diseases, and in particular in synucleinopathies. These disorders present with a variable extent of cognitive impairment and alpha-synuclein is being explored as a biomarker in CSF, blood serum and plasma. Considering key events of aging that include proteostasis, alpha-synuclein may not only be useful as a marker for differential diagnosis but also for aging per se. To explore this hypothesis, we developed a highly specific ELISA to measure alpha-synuclein. In healthy males plasma alpha-synuclein levels correlated strongly with age, revealing much lower concentrations in older (avg. 58.1 years compared to younger (avg. 27.6 years individuals. This difference between the age groups was enhanced after acidification of the plasmas (p<0.0001, possibly reflecting a decrease of alpha-synuclein-antibody complexes or chaperone activity in older individuals. Our results support the concept that alpha-synuclein homeostasis may be impaired early on, possibly due to disturbance of the proteostasis network, a key component of healthy aging. Thus, alpha-synuclein may be a novel biomarker of aging, a factor that should be considered when analyzing its presence in biological specimens.

  2. The prognostic blood biomarker proadrenomedullin for outcome prediction in patients with chronic obstructive pulmonary disease (COPD): a qualitative clinical review.

    Science.gov (United States)

    Schuetz, Philipp; Marlowe, Robert J; Mueller, Beat

    2015-03-01

    Plasma proadrenomedullin (ProADM) is a blood biomarker that may aid in multidimensional risk assessment of patients with chronic obstructive pulmonary disease (COPD). Co-secreted 1:1 with adrenomedullin (ADM), ProADM is a less biologically active, more chemically stable surrogate for this pluripotent regulatory peptide, which due to biological and ex vivo physical characteristics is difficult to reliably directly quantify. Upregulated by hypoxia, inflammatory cytokines, bacterial products, and shear stress and expressed widely in pulmonary cells and ubiquitously throughout the body, ADM exerts or mediates vasodilatory, natriuretic, diuretic, antioxidative, anti-inflammatory, antimicrobial, and metabolic effects. Observational data from four separate studies totaling 1366 patients suggest that as a single factor, ProADM is a significant independent, and accurate, long-term all-cause mortality predictor in COPD. This body of work also suggests that combined with different groups of demographic/clinical variables, ProADM provides significant incremental long-term mortality prediction power relative to the groups of variables alone. Additionally, the literature contains indications that ProADM may be a global cardiopulmonary stress marker, potentially supplying prognostic information when cardiopulmonary exercise testing results such as 6-min walk distance are unavailable due to time or other resource constraints or to a patient's advanced disease. Prospective, randomized, controlled interventional studies are needed to demonstrate whether ProADM use in risk-based guidance of site-of-care, monitoring, and treatment decisions improves clinical, quality-of-life, or pharmacoeconomic outcomes in patients with COPD.

  3. Chemical Evolution of Strongly Interacting Quark-Gluon Plasma

    International Nuclear Information System (INIS)

    Pan, Ying-Hua; Zhang, Wei-Ning

    2014-01-01

    At very initial stage of relativistic heavy ion collisions a wave of quark-gluon matter is produced from the break-up of the strong color electric field and then thermalizes at a short time scale (~1 fm/c). However, the quark-gluon plasma (QGP) system is far out of chemical equilibrium, especially for the heavy quarks which are supposed to reach chemical equilibrium much late. In this paper a continuing quark production picture for strongly interacting QGP system is derived, using the quark number susceptibilities and the equation of state; both of them are from the results calculated by the Wuppertal-Budapest lattice QCD collaboration. We find that the densities of light quarks increase by 75% from the temperature T=400 MeV to T=150 MeV, while the density of strange quark annihilates by 18% in the temperature region. We also offer a discussion on how this late production of quarks affects the final charge-charge correlations

  4. Strangeness chemical equilibration in a quark-gluon plasma

    International Nuclear Information System (INIS)

    Letessier, Jean; Rafelski, Johann

    2007-01-01

    We study, in the dynamically evolving quark-gluon plasma (QGP) fireball formed in relativistic heavy ion collisions at the BNL Relativistic Heavy Ion Collider (RHIC) and CERN Large Hadron Collider (LHC), the growth of strangeness yield toward and beyond the chemical equilibrium. We account for the contribution of the direct strangeness production and evaluate the thermal-QCD strangeness production mechanisms. The specific yield of strangeness per entropy, s/S, is the primary target variable. We explore the effect of collision impact parameter, i.e., fireball size, on kinetic strangeness chemical equilibration in QGP. Insights gained in studying the RHIC data with regard to the dynamics of the fireball are applied to the study of strangeness production at the LHC. We use these results and consider the strange hadron relative particle yields at RHIC and LHC in a systematic fashion. We consider both the dependence on s/S and the direct dependence on the participant number

  5. Comparison of some effects of modification of a polylactide surface layer by chemical, plasma, and laser methods

    Energy Technology Data Exchange (ETDEWEB)

    Moraczewski, Krzysztof, E-mail: kmm@ukw.edu.pl [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Rytlewski, Piotr [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Malinowski, Rafał [Institute for Engineering of Polymer Materials and Dyes, ul. M. Skłodowskiej–Curie 55, 87-100 Toruń (Poland); Żenkiewicz, Marian [Department of Materials Engineering, Kazimierz Wielki University, Department of Materials Engineering, ul. Chodkiewicza 30, 85-064 Bydgoszcz (Poland)

    2015-08-15

    Highlights: • We modified polylactide surface layer with chemical, plasma or laser methods. • We tested selected properties and surface structure of modified samples. • We stated that the plasma treatment appears to be the most beneficial. - Abstract: The article presents the results of studies and comparison of selected properties of the modified PLA surface layer. The modification was carried out with three methods. In the chemical method, a 0.25 M solution of sodium hydroxide in water and ethanol was utilized. In the plasma method, a 50 W generator was used, which produced plasma in the air atmosphere under reduced pressure. In the laser method, a pulsed ArF excimer laser with fluency of 60 mJ/cm{sup 2} was applied. Polylactide samples were examined by using the following techniques: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and X-ray photoelectron spectroscopy (XPS). Images of surfaces of the modified samples were recorded, contact angles were measured, and surface free energy was calculated. Qualitative and quantitative analyses of chemical composition of the PLA surface layer were performed as well. Based on the survey it was found that the best modification results are obtained using the plasma method.

  6. The dynamics of contract plasma fractionation.

    Science.gov (United States)

    Farrugia, Albert; Scaramuccia, Daniela

    2017-03-01

    Plasma Derived Medicinal Products (PMDPs) are an essential component of the modern therapeutic armamentarium. They are differentiated from most other medicines in several ways, particularly the unique nature of the raw material used for their manufacture. Human plasma has been fractionated to PDMPs for the past 75 years, and the economics of manufacturing requires currently that as many products are harvested from each litre as is feasible and reflective of clinical needs. PDMPs may be purchased on the open market from the various commercial and not-for-profit (NFP) manufacturers. They may also be manufactured under contract (CM) from plasma supplied by government and similar agencies as a product of blood transfusion services. Clients for CM aspire to make full use of donated plasma, hence maximizing the donors' gift after the standard components of transfusion have been harvested. Many such countries also aspire to making their national clinical needs self-sufficient in PDMPs, attempting to acquire strategic independence from the vagaries of the commercial open market. The increasing commercial imperatives operating in the PMDP sector generate a tension with such ethical aspirations which are not easily resolved. In particular, the need to harvest as many proteins as possible may generate products which are surplus to national needs, necessitating an ethical paradigm for the optimal provision of such products. In addition, traditional relationships between blood services and domestic fractionation agencies may come under stress as a result of the competitive processes underpinning such transactions, which are now subject to international norms of free trade. Blood services engaged in the supply of hospital transfusion components are detached from the pharmaceutical Good Manufacturing Practices (GMP) culture needed for the production of plasma for CM, while the generation of such plasma through extraction from whole blood donations deflects the focus from that of

  7. Effects of previous protein intake on rectal temperature, blood glucose, plasma thyroid hormone and minerals by laying hens during a forced molt

    International Nuclear Information System (INIS)

    Rodrigues, G.A.; Moraes, V.M.B.; Cherici, I; Furlan, R.L.; Macari, M.

    1991-01-01

    The effects of forced molting on blood glucose, rectal temperature, plasma T4, T3 and minerals were studied in hens previously fed rations with different protein contents (14, 17 and 20% crude protein). Blood samples were obtained from brachial veins for blood glucose, T4 and T3 were measured by radioimmunoassay, and plasma minerals were determined by atomic absorption spectroscopy. Blood glucose and rectal temperature were reduced during fasting regardless of previous protein intake. Pre molting T4 plasma level was higher in laying hens fed higher protein ration, but feed deprivation reduced T 4 and T 3 concentrations irrespective of protein intake, except T 4 level for 14% crude protein fed birds that increased during fasting. The data obtained in this experiment suggest that previous protein intake does not interfere with the metabolic changes during forced molt. (author). 19 refs, 1 fig, 4 tabs

  8. Effects of previous protein intake on rectal temperature, blood glucose, plasma thyroid hormone and minerals by laying hens during a forced molt

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, G A; Moraes, V M.B.; Cherici, I; Furlan, R L; Macari, M [UNESP, Jaboticabal, SP (Brazil). Faculdade de Ciencias Agrarias e Veterinarias

    1991-12-01

    The effects of forced molting on blood glucose, rectal temperature, plasma T4, T3 and minerals were studied in hens previously fed rations with different protein contents (14, 17 and 20% crude protein). Blood samples were obtained from brachial veins for blood glucose, T4 and T3 were measured by radioimmunoassay, and plasma minerals were determined by atomic absorption spectroscopy. Blood glucose and rectal temperature were reduced during fasting regardless of previous protein intake. Pre molting T4 plasma level was higher in laying hens fed higher protein ration, but feed deprivation reduced T{sub 4} and T{sub 3} concentrations irrespective of protein intake, except T{sub 4} level for 14% crude protein fed birds that increased during fasting. The data obtained in this experiment suggest that previous protein intake does not interfere with the metabolic changes during forced molt. (author). 19 refs, 1 fig, 4 tabs.

  9. Effect of Low Dose Gamma Radiation Upon the Concentration of Calcium and Inorganic Phosphorus in the Blood Plasma of Chickens

    International Nuclear Information System (INIS)

    Kraljevic, P.; Vilic, M.; Miljanic, S.; Simpraga, M.

    2003-01-01

    In our previous paper it has been showed that the irradiation of chickens eggs before incubation by low dose gamma irradiation effects upon growth of the chickens hatched from irradiated eggs as well as upon activity of ALT and AST, and on the concentration of total proteins, glucose and cholesterol in the blood plasma of those chickens. Therefore in this paper an attempt was made to determine the effects of irradiation of eggs by low dose of ionizing radiation on the 19th day of incubation upon the concentration of calcium (Ca) and inorganic phosphorus (P) in the blood plasma of chickens hatched from irradiated eggs. The eggs of heavy breeding chickens (Gent, line COBB 500) were irradiated by a dose of 0.15 Gy gamma radiation (6 0C o source) on the 19th day of incubation. Along with the chickens, which were hatched from irradiated eggs, there was a control group of chickens hatched from nonirradiated eggs. All other conditions were the same for both groups. After hatching, blood samples were taken on day 1, 3, 5, 7, 10, 20, 30 and 42. The concentration of Ca was determined calorimetrically using Randox optimized kits, while the concentration of P was determined by Herbos dijagnostika Sisak (Croatia) optimized kits. The concentration of Ca in the blood plasma of chickens hatched from irradiated eggs was significantly increased on the first day, while it was decreased on the day 42. The concentration of P was decreased on the first day in blood plasma of chickens hatched from irradiated eggs. The fact that the concentration of both minerals in blood plasma of chickens hatched from irradiated eggs was significantly changed on the first day proves that the irradiation of eggs by low dose of ionizing radiation on the nineteenth day of incubation had an effect on metabolism of both minerals in those chickens. (author)

  10. Concentration of Proteins and Protein Fractions in Blood Plasma of Chickens Hatched from Eggs Irradiated with Low Level Gamma Rays

    International Nuclear Information System (INIS)

    Kraljevic, P.; Vilic, M.; Simpraga, M.; Matisic, D.; Miljanic, S.

    2011-01-01

    In literature there are many results which have shown that low dose radiation can stimulate many physiological processes of living organism. In our earlier paper it was shown that low dose of gamma radiation has a stimulative effect upon metabolic process in chickens hatched from eggs irradiated before incubation. This was proved by increase of body weight gain and body weight, as well as by increase of two enzymes activities in blood plasma (aspartate aminotransferase and alanine aminotransferase) which play an important role in protein metabolism. Therefore, an attempt was made to determine the effect of eggs irradiation by low dose gamma rays upon concentration of total proteins and protein fractions in the blood plasma of chickens hatched from irradiated eggs. The eggs of heavy breed chickens were irradiated with a dose of 0.15 Gy gamma radiation (60Co) before incubation. Along with the chickens which were hatched from irradiated eggs, there was a control group of chickens hatched from nonirradiated eggs. All other conditions were the same for both groups of chickens. Blood samples were taken from the right jugular vein on the 1 s t and 3 r d day, or from the wing vein on days 5 and 7 after hatching. The total proteins concentration in the blood plasma was determined by the biuret method using Boehringer Mannheim GmbH optimized kits. The protein fractions (albumin, α 1 -globulin, α 2 -globulin, β- and γ-globulins) were estimated electrophoretically on Cellogel strips. The total proteins concentration was significantly decreased in blood plasma of chickens hatched from irradiated eggs on days 3 (P t h day (P 2 -globulin was decreased on days 1 (P t h day of life. Obtained results indicate that low dose of gamma radiation has mostly inhibitory effect upon concentration of total proteins and protein fractions in the blood plasma of chickens hatched from irradiated eggs before incubation. (author)

  11. Plasma concentration of ionized calcium in healthy iguanas.

    Science.gov (United States)

    Dennis, P M; Bennett, R A; Harr, K E; Lock, B A

    2001-08-01

    To measure plasma concentration of ionized calcium in healthy green iguanas. Prospective study. 9 juvenile and 21 (10 male, 11 female) adult iguanas. Blood samples were obtained from each iguana, and plasma calcium, glucose, phosphorus, uric acid, total protein, albumin, globulin, potassium, and ionized calcium concentrations, aspartate transaminase (AST) activity, and pH were measured. Heparinized blood was used for measurement of ionized calcium concentration and blood pH. A CBC was also performed to assess the health of the iguanas. Significant differences were not detected among the 3 groups (juveniles, males, and females) with regard to ionized calcium concentration. Mean ionized calcium concentration measured in blood was 1.47 +/- 0.105 mmol/L. Significant differences were detected between juveniles and adults for values of phosphorus, glucose, total protein, albumin, globulin, and AST activity. Ionized calcium concentration provides a clinical measurement of the physiologically active calcium in circulation. Evaluation of physiologically active calcium in animals with suspected calcium imbalance that have total plasma calcium concentrations within reference range or in gravid animals with considerably increased total plasma calcium concentrations is vital for determining a therapeutic plan. Accurate evaluation of calcium status will provide assistance in the diagnosis of renal disease and seizures and allow for better evaluation of the health status of gravid female iguanas.

  12. BLOOD DOPING AND RISKS

    Directory of Open Access Journals (Sweden)

    Goran Vasić

    2015-05-01

    Full Text Available Doping is the way in which athletes misuse of chemicals and other types of medical interventions (eg, blood replacement, try to get ahead in the results of other athletes or their performance at the expense of their own health. The aim of this work is the analysis of blood doping and the display of negative consequences that this way of increasing capabilities brings. Method: The methodological work is done descriptively. Results: Even in 1972 at the Stockholm Institute for gymnastics and sport, first Dr. Bjorn Ekblom started having blood doping. Taken from the blood, athletes through centifuge separating red blood cells from blood plasma, which is after a month of storage in the fridge, every athlete back into the bloodstream. Tests aerobic capacity thereafter showed that the concerned athletes can run longer on average for 25% of the treadmill than before. Discussion: Blood doping carries with it serious risks, excessive amount of red cells “thickens the blood,” increased hematocrit, which reduces the heart’s ability to pump blood to the periphery. All this makes it difficult for blood to flow through blood vessels, and there is a great danger that comes to a halt in the circulation, which can cause cardiac arrest, stroke, pulmonary edema, and other complications that can be fatal.

  13. Determination of Efavirenz in Human Dried Blood Spots by Reversed-Phase High Performance Liquid Chromatography with UV Detection

    Science.gov (United States)

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-01-01

    Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446

  14. Metabolic targets of endocrine disrupting chemicals assessed by cord blood transcriptome profiling

    DEFF Research Database (Denmark)

    Remy, Sylvie; Govarts, Eva; Wens, Britt

    2016-01-01

    Early life exposure to endocrine disrupting chemicals (EDCs) has been frequently associated with impaired perinatal growth, an important risk factor for later onset of metabolic disorders. We analyzed whether the cord blood transcriptome showed early indications of alterations in metabolic...

  15. Microdose clinical trial: quantitative determination of nicardipine and prediction of metabolites in human plasma.

    Science.gov (United States)

    Yamane, Naoe; Takami, Tomonori; Tozuka, Zenzaburo; Sugiyama, Yuichi; Yamazaki, Akira; Kumagai, Yuji

    2009-01-01

    A sample treatment procedure and high-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantitative determination of nicardipine in human plasma were developed for a microdose clinical trial with nicardipine, a non-radioisotope labeled drug. The calibration curve was linear in the range of 1-500 pg/mL using 1 mL of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 0.2-100 ng/mL using 20 microL of plasma, was also conducted. Each method was successfully applied to making determinations in plasma using LC/MS/MS after administration of a microdose (100 microg) and clinical dose (20 mg) to each of six healthy volunteers. We tested new approaches in the search for metabolites in plasma after microdosing. In vitro metabolites of nicardipine were characterized using linear ion trap-fourier transform ion cyclotron resonance mass spectrometry (LIT-FTICRMS) and the nine metabolites predicted to be in plasma were analyzed using LC/MS/MS. There is a strong possibility that analysis of metabolites by LC/MS/MS may advance to utilization in microdose clinical trials with non-radioisotope labeled drugs.

  16. Effect of postmortem sampling technique on the clinical significance of autopsy blood cultures.

    Science.gov (United States)

    Hove, M; Pencil, S D

    1998-02-01

    Our objective was to investigate the value of postmortem autopsy blood cultures performed with an iodine-subclavian technique relative to the classical method of atrial heat searing and antemortem blood cultures. The study consisted of a prospective autopsy series with each case serving as its own control relative to subsequent testing, and a retrospective survey of patients coming to autopsy who had both autopsy blood cultures and premortem blood cultures. A busy academic autopsy service (600 cases per year) at University of Texas Medical Branch Hospitals, Galveston, Texas, served as the setting for this work. The incidence of non-clinically relevant (false-positive) culture results were compared using different methods for collecting blood samples in a prospective series of 38 adult autopsy specimens. One hundred eleven adult autopsy specimens in which both postmortem and antemortem blood cultures were obtained were studied retrospectively. For both studies, positive culture results were scored as either clinically relevant or false positives based on analysis of the autopsy findings and the clinical summary. The rate of false-positive culture results obtained by an iodine-subclavian technique from blood drawn soon after death were statistically significantly lower (13%) than using the classical method of obtaining blood through the atrium after heat searing at the time of the autopsy (34%) in the same set of autopsy subjects. When autopsy results were compared with subjects' antemortem blood culture results, there was no significant difference in the rate of non-clinically relevant culture results in a paired retrospective series of antemortem blood cultures and postmortem blood cultures using the iodine-subclavian postmortem method (11.7% v 13.5%). The results indicate that autopsy blood cultures obtained using the iodine-subclavian technique have reliability equivalent to that of antemortem blood cultures.

  17. Cold flame on Biofilm - Transport of Plasma Chemistry from Gas to Liquid Phase

    Science.gov (United States)

    Kong, Michael

    2014-10-01

    One of the most active and fastest growing fields in low-temperature plasma science today is biological effects of gas plasmas and their translation in many challenges of societal importance such as healthcare, environment, agriculture, and nanoscale fabrication and synthesis. Using medicine as an example, there are already three FDA-approved plasma-based surgical procedures for tissue ablation and blood coagulation and at least five phase-II clinical trials on plasma-assisted wound healing therapies. A key driver for realizing the immense application potential of near room-temperature ambient pressure gas plasmas, commonly known as cold atmospheric plasmas or CAP, is to build a sizeable interdisciplinary knowledge base with which to unravel, optimize, and indeed design how reactive plasma species interact with cells and their key components such as protein and DNA. Whilst a logical objective, it is a formidable challenge not least since existing knowledge of gas discharges is largely in the gas-phase and therefore not directly applicable to cell-containing matters that are covered by or embedded in liquid (e.g. biofluid). Here, we study plasma inactivation of biofilms, a jelly-like structure that bacteria use to protect themselves and a major source of antimicrobial resistance. As 60--90% of biofilm is made of water, we develop a holistic model incorporating physics and chemistry in the upstream CAP-generating region, a plasma-exit region as a buffer for as-phase transport, and a downstream liquid region bordering the gas buffer region. A special model is developed to account for rapid chemical reactions accompanied the transport of gas-phase plasma species through the gas-liquid interface and for liquid-phase chemical reactions. Numerical simulation is used to illustrate how key reactive oxygen species (ROS) are transported into the liquid, and this is supported with experimental data of both biofilm inactivation using plasmas and electron spin spectroscopy (ESR

  18. Detection of cervical cancer biomarker patterns in blood plasma and urine by differential scanning calorimetry and mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Nichola C Garbett

    Full Text Available Improved methods for the accurate identification of both the presence and severity of cervical intraepithelial neoplasia (CIN and extent of spread of invasive carcinomas of the cervix (IC are needed. Differential scanning calorimetry (DSC has recently been shown to detect specific changes in the thermal behavior of blood plasma proteins in several diseases. This methodology is being explored to provide a complementary approach for screening of cervical disease. The present study evaluated the utility of DSC in differentiating between healthy controls, increasing severity of CIN and early and advanced IC. Significant discrimination was apparent relative to the extent of disease with no clear effect of demographic factors such as age, ethnicity, smoking status and parity. Of most clinical relevance, there was strong differentiation of CIN from healthy controls and IC, and amongst patients with IC between FIGO Stage I and advanced cancer. The observed disease-specific changes in DSC profiles (thermograms were hypothesized to reflect differential expression of disease biomarkers that subsequently bound to and affected the thermal behavior of the most abundant plasma proteins. The effect of interacting biomarkers can be inferred from the modulation of thermograms but cannot be directly identified by DSC. To investigate the nature of the proposed interactions, mass spectrometry (MS analyses were employed. Quantitative assessment of the low molecular weight protein fragments of plasma and urine samples revealed a small list of peptides whose abundance was correlated with the extent of cervical disease, with the most striking plasma peptidome data supporting the interactome theory of peptide portioning to abundant plasma proteins. The combined DSC and MS approach in this study was successful in identifying unique biomarker signatures for cervical cancer and demonstrated the utility of DSC plasma profiles as a complementary diagnostic tool to evaluate

  19. Detection of cervical cancer biomarker patterns in blood plasma and urine by differential scanning calorimetry and mass spectrometry.

    Science.gov (United States)

    Garbett, Nichola C; Merchant, Michael L; Helm, C William; Jenson, Alfred B; Klein, Jon B; Chaires, Jonathan B

    2014-01-01

    Improved methods for the accurate identification of both the presence and severity of cervical intraepithelial neoplasia (CIN) and extent of spread of invasive carcinomas of the cervix (IC) are needed. Differential scanning calorimetry (DSC) has recently been shown to detect specific changes in the thermal behavior of blood plasma proteins in several diseases. This methodology is being explored to provide a complementary approach for screening of cervical disease. The present study evaluated the utility of DSC in differentiating between healthy controls, increasing severity of CIN and early and advanced IC. Significant discrimination was apparent relative to the extent of disease with no clear effect of demographic factors such as age, ethnicity, smoking status and parity. Of most clinical relevance, there was strong differentiation of CIN from healthy controls and IC, and amongst patients with IC between FIGO Stage I and advanced cancer. The observed disease-specific changes in DSC profiles (thermograms) were hypothesized to reflect differential expression of disease biomarkers that subsequently bound to and affected the thermal behavior of the most abundant plasma proteins. The effect of interacting biomarkers can be inferred from the modulation of thermograms but cannot be directly identified by DSC. To investigate the nature of the proposed interactions, mass spectrometry (MS) analyses were employed. Quantitative assessment of the low molecular weight protein fragments of plasma and urine samples revealed a small list of peptides whose abundance was correlated with the extent of cervical disease, with the most striking plasma peptidome data supporting the interactome theory of peptide portioning to abundant plasma proteins. The combined DSC and MS approach in this study was successful in identifying unique biomarker signatures for cervical cancer and demonstrated the utility of DSC plasma profiles as a complementary diagnostic tool to evaluate cervical cancer

  20. Immobilized enzymes in blood plasma exchangers via radiation grafting

    Science.gov (United States)

    Gombotz, Wayne; Hoffman, Allan; Schmer, Gottfried; Uenoyama, Satoshi

    The enzyme asparaginase was immobilized onto a porous hollow polypropylene (PP) fiber blood plasma exchange device for the treatment of acute lymphocytic leukemia. The devices were first radiation grafted with polymethacrylic acid (poly(MAAc)). This introduces carboxyl groups onto the surface of the fibers. Several variables were studied in the grafting reaction including the effects of solvent type and monomer concentration. The carboxyl groups were activated with N-hydroxy succinimide (NHS) using carbodiimide chemistry. Asparaginase was then covalently immobilized on the activated surfaces. Quantitative relationships were found relating the percent graft to the amount of immobilized enzyme which was active. The enzyme reactor was tested both in vitro and in vivo using a sheep as an animal model.

  1. Plasma metabolic profiling of dairy cows affected with clinical ketosis using LC/MS technology.

    Science.gov (United States)

    Li, Y; Xu, C; Xia, C; Zhang, Hy; Sun, Lw; Gao, Y

    2014-01-01

    Ketosis in dairy cattle is an important metabolic disorder. Currently, the plasma metabolic profile of ketosis as determined using liquid chromatography-mass spectrometry (LC/MS) has not been reported. To investigate plasma metabolic profiles from cows with clinical ketosis in comparison to control cows. Twenty Holstein dairy cows were divided into two groups based on clinical signs and plasma β-hydroxybutyric acid and glucose concentrations 7-21 days postpartum: clinical ketosis and control cows. Plasma metabolic profiles were analyzed using LC/MS. Data were processed using principal component analysis and orthogonal partial least-squares discriminant analysis. Compared to control cows, the levels of valine, glycine, glycocholic, tetradecenoic acid, and palmitoleic acid increased significantly in clinical ketosis. On the other hand, the levels of arginine, aminobutyric acid, leucine/isoleucine, tryptophan, creatinine, lysine, norcotinine, and undecanoic acid decreased markedly. Our results showed that the metabolic changes in cows with clinical ketosis involve complex metabolic networks and signal transduction. These results are important for future studies elucidating the pathogenesis, diagnosis, and prevention of clinical ketosis in dairy cows.

  2. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  3. Ambulatory blood pressure and urinary albumin excretion in clinically healthy subjects

    DEFF Research Database (Denmark)

    Clausen, Peter Vilhelm; Jensen, J S; Borch-Johnsen, K

    1998-01-01

    UAER. Because 24-hour ambulatory blood pressure is a superior predictor of hypertensive target organ involvement, we aimed to investigate blood pressure profile in clinically healthy subjects with elevated UAER. Ambulatory blood pressure monitoring was performed with a portable recorder in 27 subjects...... loss of albumin could not be solely related to the higher blood pressure. In conclusion, apparently healthy subjects with elevated UAER had slightly but significantly higher 24-hour systolic and diastolic blood pressure levels in addition to increased blood pressure loads but normal circadian variation...

  4. Predictive Value of Whole Blood and Plasma Coagulation Tests for Intra- and Postoperative Bleeding Risk: A Systematic Review

    DEFF Research Database (Denmark)

    Larsen, Julie Brogaard; Hvas, Anne-Mette

    2017-01-01

    review of the existing literature assessing the ability of whole blood coagulation (thromboelastography [TEG]/thromboelastometry [ROTEM]/Sonoclot), platelet function tests, and standard plasma-based coagulation tests to predict bleeding in the perioperative setting. We searched PubMed and Embase...... value of testing in patients receiving antithrombotic medication. In general, studies reported low positive predictive values for perioperative testing, whereas negative predictive values were high. The studies yielded moderate areas under receiver operator characteristics (ROC) curve (for the majority...... recommend that both whole blood and plasma-based coagulation tests are primarily used in case of bleeding and not for screening in unselected patients prior to surgery....

  5. Induction of hepatic protein synthesis by a peptide in blood plasma of patients with sepsis and trauma.

    Science.gov (United States)

    Loda, M; Clowes, G H; Dinarello, C A; George, B C; Lane, B; Richardson, W

    1984-08-01

    Accelerated release of amino acids from muscle and their uptake for protein synthesis by liver and other visceral tissues are characteristic of trauma or sepsis. Experimentally, this response is induced by interleukin-1 (IL-1) generated by activated macrophages in vitro. However, IL-1 has not been demonstrated in human blood. A small 4000-dalton peptide recently isolated from plasma of patients with sepsis and trauma induces muscle proteolysis and is called "proteolysis-inducing factor" (PIF). To test whether this agent has the ability also to induce hepatic protein synthesis, a series of animal experiments and clinical observations were undertaken. The structural and secretory (acute-phase reactants) in vitro protein synthesis in livers of normal rats injected intraperitoneally with IL-1 or PIF was significantly greater than that of normal rats or those injected with Ringer's lactate (p less than 0.01). In patients with sepsis and trauma the central plasma clearance rate of amino acids, a measure of visceral (principally hepatic) amino acid uptake, was elevated and correlated with the rates of protein synthesis in incubated liver slices obtained by biopsy at operation from the same patients (p less than 0.05). Both in vivo measured central plasma clearance rate of amino acids and in vitro measured hepatic protein synthesis correlated with plasma levels of PIF in the same patients (p less than 0.01 and p less than 0.05, respectively). We conclude that since PIF, and not IL-1, is present in human plasma and both are produced by activated macrophages, PIF seems to be the stable circulating cleavage product of IL-1, which induces not only muscle proteolysis but also hepatic protein synthesis, principally in the form of acute-phase reactants during infection and other states in which inflammation is present.

  6. Observation of non-chemical equilibrium effect on Ar-CO2-H2 thermal plasma model by changing pressure

    International Nuclear Information System (INIS)

    Al-Mamun, Sharif Abdullah; Tanaka, Yasunori; Uesugi, Yoshihiko

    2009-01-01

    The authors developed a two-dimensional one-temperature chemical non-equilibrium (1T-NCE) model of Ar-CO 2 -H 2 inductively coupled thermal plasmas (ICTP) to investigate the effect of pressure variation. The basic concept of one-temperature model is the assumption and treatment of the same energy conservation equation for electrons and heavy particles. The energy conservation equations consider reaction heat effects and energy transfer among the species produced as well as enthalpy flow resulting from diffusion. Assuming twenty two (22) different particles in this model and by solving mass conservation equations for each particle, considering diffusion, convection and net production terms resulting from hundred and ninety eight (198) chemical reactions, chemical non-equilibrium effects were taken into account. Transport and thermodynamic properties of Ar-CO 2 -H 2 thermal plasmas were self-consistently calculated using the first-order approximation of the Chapman-Enskog method. Finally results obtained at atmospheric pressure (760 Torr) and at reduced pressure (500, 300 Torr) were compared with results from one-temperature chemical equilibrium (1T-CE) model. And of course, this comparison supported discussion of chemical non-equilibrium effects in the inductively coupled thermal plasmas (ICTP).

  7. Determination of the total drug-related chlorine and bromine contents in human blood plasma using high performance liquid chromatography-tandem ICP-mass spectrometry (HPLC-ICP-MS/MS).

    Science.gov (United States)

    Klencsár, Balázs; Bolea-Fernandez, Eduardo; Flórez, María R; Balcaen, Lieve; Cuyckens, Filip; Lynen, Frederic; Vanhaecke, Frank

    2016-05-30

    A fast, accurate and precise method for the separation and determination of the total contents of drug-related Cl and Br in human blood plasma, based on high performance liquid chromatography - inductively coupled plasma - tandem mass spectrometry (HPLC-ICP-MS/MS), has been developed. The novel approach was proved to be a suitable alternative to the presently used standard methodology (i.e. based on a radiolabelled version of the drug molecule and radiodetection), while eliminating the disadvantages of the latter. Interference-free determination of (35)Cl has been accomplished via ICP-MS/MS using H2 as reaction gas and monitoring the (35)ClH2(+) reaction product at mass-to-charge ratio of 37. Br could be measured "on mass" at a mass-to-charge of 79. HPLC was relied on for the separation of the drug-related entities from the substantial amount of inorganic Cl. The method developed was found to be sufficiently precise (repeatability 0.990) from the limit of quantification (0.05 and 0.01 mg/L for Cl and Br in blood plasma, respectively) to at least 5 and 1mg/L for Cl and Br, respectively. Quantification via either external or internal standard calibration provides reliable results for both elements. As a proof-of-concept, human blood plasma samples from a clinical study involving a newly developed Cl- and Br-containing active pharmaceutical ingredient were analysed and the total drug exposure was successfully described. Cross-validation was achieved by comparing the results obtained on Cl- and on Br-basis. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Fish oil affects blood pressure and the plasma lipid profile in healthy Danish infants

    DEFF Research Database (Denmark)

    Damsgaard, C.T.; Schack-Nielsen, L.; Michaelsen, K.F.

    2006-01-01

    with an oscillometric device, and blood was sampled for analysis of erythrocyte fatty acid composition and the plasma lipid profile. This paper examines the effects of the fish oil supplement, with adjustment for the effects of the milk intervention when relevant. The fish oil intervention increased erythrocyte (n-3......Animal and epidemiologic studies indicate that early nutrition has lasting effects on metabolism and cardiovascular disease risk. In adults, (n-3) long-chain PUFA (LCPUFA) from fish oils improve blood pressure, the lipid profile, and possibly cardiovascular disease mortality. This randomized trial...... is the first to investigate the effects of fish oil on blood pressure and the lipid profile in infancy. Healthy term 9-mo old infants In 83) were randomly assigned to 5 mL fish oil daily or no fish oil for 3 mo and to 2 different milk types. Before and after the intervention, blood pressure was measured...

  9. Inactivation of Escherichia coli on blueberries using cold plasma with chemical augmentation inside a partial vacuum

    Science.gov (United States)

    Justification: The mechanism by which cold plasma inactivates pathogens is through the production of free reactive chemical species. Unfortunately, the most reactive chemical species have the shortest half-life. In a vacuum their half-life is believed to be prolonged. Additionally, these reactive sp...

  10. Level of Interleukins IL-6 and IL-15 in Blood Plasma of Mice after Forced Swimming Test.

    Science.gov (United States)

    Kapilevich, L V; Kironenko, T A; Zakharova, A N; Kabachkova, A V; Orlov, S N

    2017-05-01

    We measured the concentrations of IL-6 and IL-15 in blood plasma of mice at different terms after forced swimming, taking into account exercise intensity and preliminary training. It was shown that training was an important factor affecting blood plasma level of IL both at rest and after single forced swimming: in trained animals, the concentration of both myokines increased immediately after swimming, while in untrained animals, this increase was observed only after 5 h. Changes in cytokine production against the background of training can be associated with various factors, including neuroendocrine mechanisms, stress, modification of intracellular signaling, as well as reorganization of transcriptional mechanisms in muscle fibers. The most important factor is shift in the ratio of monovalent cations (sodium and potassium) in the cytoplasm.

  11. Room-temperature plasma-enhanced chemical vapor deposition of SiOCH films using tetraethoxysilane

    International Nuclear Information System (INIS)

    Yamaoka, K.; Yoshizako, Y.; Kato, H.; Tsukiyama, D.; Terai, Y.; Fujiwara, Y.

    2006-01-01

    Carbon-doped silicon oxide (SiOCH) thin films were deposited by room-temperature plasma-enhanced chemical vapor deposition (PECVD) using tetraethoxysilane (TEOS). The deposition rate and composition of the films strongly depended on radio frequency (RF) power. The films deposited at low RF power contained more CH n groups. The SiOCH films showed high etch rate and low refractive index in proportion to the carbon composition. The deposition with low plasma density and low substrate temperature is effective for SiOCH growth by PECVD using TEOS

  12. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    Science.gov (United States)

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  13. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine.

    Science.gov (United States)

    Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello

    2018-05-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Hyperammonaemia, plasma aminoacid imbalance, and blood-brain aminoacid transport: a unified theory of portal-systemic encephalopathy.

    Science.gov (United States)

    James, J H; Ziparo, V; Jeppsson, B; Fischer, J E

    1979-10-13

    It is proposed that hyperammonaemia in liver cirrhosis or after portacaval shunt contributes to plasma neutral aminoacid imbalance and to increased activity of the blood-brain neutral amino-acid transport system. Plasma neutral aminoacid concentrations are deranged, partly, but not completely, because ammonia stimulates glucagon secretion; a high rate of gluconeogenesis and hyperinsulinaemia follow. Brain uptake of neutral aminoacids rises because ammonia stimulates brain-glutamine synthesis, which results in rapid exchange of brain glutamine for plasma neutral aminoacids. Hyperammonaemia therefore contributes to encephalopathy indirectly, by raising the brain concentration of neutral aminoacids which after neurotransmitter metabolism, rather than directly, by toxic effects on neuronal metabolism.

  15. Screening and hit evaluation of a chemical library against blood-stage Plasmodium falciparum.

    Science.gov (United States)

    Avery, Vicky M; Bashyam, Sridevi; Burrows, Jeremy N; Duffy, Sandra; Papadatos, George; Puthukkuti, Shyni; Sambandan, Yuvaraj; Singh, Shivendra; Spangenberg, Thomas; Waterson, David; Willis, Paul

    2014-05-27

    In view of the need to continuously feed the pipeline with new anti-malarial agents adapted to differentiated and more stringent target product profiles (e.g., new modes of action, transmission-blocking activity or long-duration chemo-protection), a chemical library consisting of more than 250,000 compounds has been evaluated in a blood-stage Plasmodium falciparum growth inhibition assay and further assessed for chemical diversity and novelty. The selection cascade used for the triaging of hits from the chemical library started with a robust three-step in vitro assay followed by an in silico analysis of the resulting confirmed hits. Upon reaching the predefined requirements for selectivity and potency, the set of hits was subjected to computational analysis to assess chemical properties and diversity. Furthermore, known marketed anti-malarial drugs were co-clustered acting as 'signposts' in the chemical space defined by the hits. Then, in cerebro evaluation of the chemical structures was performed to identify scaffolds that currently are or have been the focus of anti-malarial medicinal chemistry programmes. Next, prioritization according to relaxed physicochemical parameters took place, along with the search for structural analogues. Ultimately, synthesis of novel chemotypes with desired properties was performed and the resulting compounds were subsequently retested in a P. falciparum growth inhibition assay. This screening campaign led to a 1.25% primary hit rate, which decreased to 0.77% upon confirmatory repeat screening. With the predefined potency (EC₅₀  10) criteria, 178 compounds progressed to the next steps where chemical diversity, physicochemical properties and novelty assessment were taken into account. This resulted in the selection of 15 distinct chemical series. A selection cascade was applied to prioritize hits resulting from the screening of a medium-sized chemical library against blood-stage P. falciparum. Emphasis was placed on chemical

  16. Informing the Human Plasma Protein Binding of Environmental Chemicals by Machine Learning in the Pharmaceutical Space: Applicability Domain and Limits of Predictability

    Science.gov (United States)

    The free fraction of a xenobiotic in plasma (Fub) is an important determinant of chemical adsorption, distribution, metabolism, elimination, and toxicity, yet experimental plasma protein binding data is scarce for environmentally relevant chemicals. The presented work explores th...

  17. Polyethylene Oxide Films Polymerized by Radio Frequency Plasma-Enhanced Chemical Vapour Phase Deposition and Its Adsorption Behaviour of Platelet-Rich Plasma

    International Nuclear Information System (INIS)

    Wen-Juan, Hu; Fen-Yan, Xie; Qiang, Chen; Jing, Weng

    2008-01-01

    We present polyethylene oxide (PEO) functional films polymerized by rf plasma-enhanced vapour chemical deposition (rf-PECVD) on p-Si (100) surface with precursor ethylene glycol dimethyl ether (EGDME) and diluted Ar in pulsed plasma mode. The influences of discharge parameters on the film properties and compounds are investigated. The film structure is analysed by Fourier transform infrared (FTIR) spectroscopy. The water contact angle measurement and atomic force microscope (AFM) are employed to examine the surface polarity and to detect surface morphology, respectively. It is concluded that the smaller duty cycle in pulsed plasma mode contributes to the rich C-O-C (EO) group on the surfaces. As an application, the adsorption behaviour of platelet-rich plasma on plasma polymerization films performed in-vitro is explored. The shapes of attached cells are studied in detail by an optic invert microscope, which clarifies that high-density C-O-C groups on surfaces are responsible for non-fouling adsorption behaviour of the PEO films

  18. Polyethylene Oxide Films Polymerized by Radio Frequency Plasma-Enhanced Chemical Vapour Phase Deposition and Its Adsorption Behaviour of Platelet-Rich Plasma

    Science.gov (United States)

    Hu, Wen-Juan; Xie, Fen-Yan; Chen, Qiang; Weng, Jing

    2008-10-01

    We present polyethylene oxide (PEO) functional films polymerized by rf plasma-enhanced vapour chemical deposition (rf-PECVD) on p-Si (100) surface with precursor ethylene glycol dimethyl ether (EGDME) and diluted Ar in pulsed plasma mode. The influences of discharge parameters on the film properties and compounds are investigated. The film structure is analysed by Fourier transform infrared (FTIR) spectroscopy. The water contact angle measurement and atomic force microscope (AFM) are employed to examine the surface polarity and to detect surface morphology, respectively. It is concluded that the smaller duty cycle in pulsed plasma mode contributes to the rich C-O-C (EO) group on the surfaces. As an application, the adsorption behaviour of platelet-rich plasma on plasma polymerization films performed in-vitro is explored. The shapes of attached cells are studied in detail by an optic invert microscope, which clarifies that high-density C-O-C groups on surfaces are responsible for non-fouling adsorption behaviour of the PEO films.

  19. Phenotype-Driven Plasma Biobanking Strategies and Methods

    Directory of Open Access Journals (Sweden)

    Erica A. Bowton

    2015-05-01

    Full Text Available Biobank development and integration with clinical data from electronic medical record (EMR databases have enabled recent strides in genomic research and personalized medicine. BioVU, Vanderbilt’s DNA biorepository linked to de-identified clinical EMRs, has proven fruitful in its capacity to extensively appeal to numerous areas of biomedical and clinical research, supporting the discovery of genotype-phenotype interactions. Expanding on experiences in BioVU creation and development, we have recently embarked on a parallel effort to collect plasma in addition to DNA from blood specimens leftover after routine clinical testing at Vanderbilt. This initiative offers expanded utility of BioVU by combining proteomic and metabolomic approaches with genomics and/or clinical outcomes, widening the breadth for potential research and subsequent future impact on clinical care. Here, we describe the considerations and components involved in implementing a plasma biobank program from a feasibility assessment through pilot sample collection.

  20. Central blood circulation in children at chronic combined low dose radiation and chemical action

    International Nuclear Information System (INIS)

    Arinchin, A.N.

    2000-01-01

    The state of central blood circulation and its hormonal regulation were studied in 1465 children living permanently under chronic low dose radiation and chemical action. Basic group consisted of 1093 children (579 boys and 514 girls) . 372 children (115 boys and 227 girls permanently living on 'clean' areas) were investigated in control group. Average age was 10,8 years old in basic group and 10,4 years old in the control group. Such parameters as arterial pressure, level of lead in blood and urine, adrenaline, noradrenaline and dophamine content in urine, thyroxine, iodothyronine, prostaglandins and cyclic AMP content in the blood serum has been controlled. Hypotensive states were determined to prevail in children living permanently under chronic low dose radiation and chemical action. The main pathogenic mechanism of this defeat is consider to be a reduction of the sympathoadrenal system activity combined with a decreasing of the thyroid system activity and of cyclic AMP level as well as predominance of prostaglandin depressive activity

  1. Cardiovascular Topics Blood pressure control at a hospital day clinic ...

    African Journals Online (AJOL)

    1999-02-01

    Feb 1, 1999 ... control in a hospital day clinic population receiving cal- cium channel ... we had showed poor control of blood pressure in this hospital-based population .... Assessment of com- .... Program are obering: 19 almost half of newly treated hyper- tensives will di ... blood pressure control and quality of life. There is ...

  2. Transferases activity in blood plasma of chickens hatched from eggs irradiated during incubation by low dose gamma rays

    International Nuclear Information System (INIS)

    Kraljevic, P.; Vilic, M.; Miljanic, S.; Simpraga, M.

    2005-01-01

    In our earlier studies chickens hatched from eggs irradiated with 0.15 Gy gamma rays before incubation showed a significantly higher growth than controls during the fattening period (1-42 days). The activity of aspartate-aminotransferase (AST), alanine-aminotransferase (ALT) and plasma glucose in the same chickens were also significantly higher. These results suggested that low-dose gamma-radiation stimulated certain metabolic processes in chickens hatched from eggs irradiated before incubation. The goal of this study was to determine the effects of low-dose ionising radiation on AST and ALT activity in the blood plasma of chickens hatched from eggs irradiated during incubation. The eggs of heavy breeding chickens (Avian, line 34) were exposed to 0.15 Gy of gamma-radiation (6 0C o) on the seventh day of incubation, i.e. at the time when the organogenesis in chickens is completed. The control group of chickens hatched from non-irradiated eggs. All other conditions were the same for both groups. After hatching, blood samples were taken from the wing vein on days 1, 3, 5, 7, 10, 20, 32 and 42. The activity of both enzymes was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. On day 10, AST and ALT activity were significantly higher in the blood plasma of chickens hatched from irradiated eggs, but it significantly dropped for both enzymes on day 20. Our results indicate that exposure of eggs to low-dose gamma-radiation on the seventh day of incubation affects AST and ALT activity in the blood plasma of chickens hatched from irradiated eggs. However, this effect is somewhat different from the effects of egg exposure to low-dose gamma radiation before incubation.(author)

  3. Nitrogen-doped graphene by microwave plasma chemical vapor deposition

    International Nuclear Information System (INIS)

    Kumar, A.; Voevodin, A.A.; Paul, R.; Altfeder, I.; Zemlyanov, D.; Zakharov, D.N.; Fisher, T.S.

    2013-01-01

    Rapid synthesis of nitrogen-doped, few-layer graphene films on Cu foil is achieved by microwave plasma chemical vapor deposition. The films are doped during synthesis by introduction of nitrogen gas in the reactor. Raman spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy and scanning tunneling microscopy reveal crystal structure and chemical characteristics. Nitrogen concentrations up to 2 at.% are observed, and the limit is linked to the rigidity of graphene films on copper surfaces that impedes further nitrogen substitutions of carbon atoms. The entire growth process requires only a few minutes without supplemental substrate heating and offers a promising path toward large-scale synthesis of nitrogen-doped graphene films. - Highlights: ► Rapid synthesis of nitrogen doped few layer graphene on Cu foil. ► Defect density increment on 2% nitrogen doping. ► Nitrogen doped graphene is a good protection to the copper metallic surface

  4. Nitrogen-doped graphene by microwave plasma chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, A., E-mail: kumar50@purdue.edu [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Voevodin, A.A. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States); Paul, R. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Altfeder, I. [Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States); Zemlyanov, D.; Zakharov, D.N. [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Fisher, T.S., E-mail: tsfisher@purdue.edu [Birck Nanotechnolgy Center, Purdue University, West Lafayette, IN 47907 (United States); Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, OH 45433 (United States)

    2013-01-01

    Rapid synthesis of nitrogen-doped, few-layer graphene films on Cu foil is achieved by microwave plasma chemical vapor deposition. The films are doped during synthesis by introduction of nitrogen gas in the reactor. Raman spectroscopy, X-ray photoelectron spectroscopy, transmission electron microscopy and scanning tunneling microscopy reveal crystal structure and chemical characteristics. Nitrogen concentrations up to 2 at.% are observed, and the limit is linked to the rigidity of graphene films on copper surfaces that impedes further nitrogen substitutions of carbon atoms. The entire growth process requires only a few minutes without supplemental substrate heating and offers a promising path toward large-scale synthesis of nitrogen-doped graphene films. - Highlights: ► Rapid synthesis of nitrogen doped few layer graphene on Cu foil. ► Defect density increment on 2% nitrogen doping. ► Nitrogen doped graphene is a good protection to the copper metallic surface.

  5. Study on stability of a-SiCOF films deposited by plasma enhanced chemical vapor deposition

    International Nuclear Information System (INIS)

    Ding Shijin; Zhang Qingquan; Wang Pengfei; Zhang Wei; Wang Jitao

    2001-01-01

    Low-dielectric-constant a-SiCOF films have been prepared from TEOS, C 4 F 8 and Ar by using plasma enhanced chemical vapor deposition method. With the aid of X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR), the chemical bonding configuration, thermal stability and resistance to water of the films are explored

  6. Effect of breed on plasma endothelin-1 concentration, plasma renin activity, and serum cortisol concentration in healthy dogs

    DEFF Research Database (Denmark)

    Höglund, K.; Lequarré, A.-S.; Ljungvall, I.

    2016-01-01

    BACKGROUND: There are breed differences in several blood variables in healthy dogs. OBJECTIVE: Investigate breed variation in plasma endothelin-1 (ET-1) concentration, plasma renin activity, and serum cortisol concentration. ANIMALS: Five-hundred and thirty-one healthy dogs of 9 breeds examined...... at 5 centers (2-4 breeds/center). METHODS: Prospective observational study. Circulating concentrations of ET-1 and cortisol, and renin activity, were measured using commercially available assays. Absence of organ-related or systemic disease was ensured by thorough clinical investigations, including...

  7. Plasma viscosity increase with progression of peripheral arterial atherosclerotic disease.

    Science.gov (United States)

    Poredos, P; Zizek, B

    1996-03-01

    Increased blood and plasma viscosity has been described in patients with coronary and peripheral arterial disease. However, the relation of viscosity to the extent of arterial wall deterioration--the most important determinant of clinical manifestation and prognosis of the disease--is not well known. Therefore, the authors studied plasma viscosity as one of the major determinants of blood viscosity in patients with different stages of arterial disease of lower limbs (according to Fontaine) and its relation to the presence of some risk factors of atherosclerosis. The study encompassed four groups of subjects: 19 healthy volunteers (group A), 18 patients with intermittent claudication up to 200 m (stage II; group B), 15 patients with critical ischemia of lower limbs (stage III and IV; group C), and 16 patients with recanalization procedures on peripheral arteries. Venous blood samples were collected from an antecubital vein without stasis for the determination of plasma viscosity (with a rotational capillary microviscometer, PAAR), fibrinogen, total cholesterol, alpha-2-macroglobulin, and glucose concentrations. In patients with recanalization procedure local plasma viscosity was also determined from blood samples taken from a vein on the dorsum of the foot. Plasma viscosity was most significantly elevated in the patients with critical ischemia (1.78 mPa.sec) and was significantly higher than in the claudicants (1.68 mPa.sec), and the claudicants also had significantly higher viscosity than the controls (1.58 mPa.sec). In patients in whom a recanalization procedure was performed, no differences in systemic and local plasma viscosity were detected, neither before nor after recanalization of the diseased artery. In all groups plasma viscosity was correlated with fibrinogen concentration (r=0.70, P < 0.01) and total cholesterol concentration (r=0.24, P < 0.05), but in group C (critical ischemia) plasma viscosity was most closely linked to the concentration of alpha-2

  8. Plasma Enhanced Chemical Vapour Deposition of Horizontally Aligned Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Matthew T. Cole

    2013-05-01

    Full Text Available A plasma-enhanced chemical vapour deposition reactor has been developed to synthesis horizontally aligned carbon nanotubes. The width of the aligning sheath was modelled based on a collisionless, quasi-neutral, Child’s law ion sheath where these estimates were empirically validated by direct Langmuir probe measurements, thereby confirming the proposed reactors ability to extend the existing sheath fields by up to 7 mm. A 7 mbar growth atmosphere combined with a 25 W plasma permitted the concurrent growth and alignment of carbon nanotubes with electric fields of the order of 0.04 V μm−1 with linear packing densities of up to ~5 × 104 cm−1. These results open up the potential for multi-directional in situ alignment of carbon nanotubes providing one viable route to the fabrication of many novel optoelectronic devices.

  9. Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats.

    Science.gov (United States)

    Yadav, R; Mohan, K; Kumar, V; Sarkar, M; Nitu, K; Meyer, H H D; Prakash, B S

    2013-08-01

    A highly sensitive enzyme immunoassay (EIA) that used the second antibody coating technique and the cortisol-horseradish peroxidase conjugate as a label for determination of free and total cortisol in blood plasma of dairy animals (cows, buffaloes, and goats) was developed. For biological validation of the EIA, blood samples were collected from the animals at 48 and 24 h before and 0, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 h after dexamethasone administration. The EIA was performed directly with 20 μL of fresh plasma (for free cortisol) and also with 20 μL of heat-treated plasma (for total cortisol) after 1:5 dilutions with PBS. Cortisol standards ranging from 0.39 to 200 pg/well/20 μL were used, and the sensitivity of the EIA procedure was found to be 0.39 pg/well/20 μL, which corresponded to 0.02 ng/mL. In comparison with RIA the EIA was at least 4 times more sensitive and required 5 times less cortisol antiserum. In female cattle, buffaloes, and goats, the total, free, and bound plasma cortisol before dexamethasone administration was significantly (P < 0.05) higher than the total, free, and bound cortisol after dexamethasone administration. It can be concluded from these studies that the direct, sensitive EIA validated for estimating the free and total cortisol concentrations was sufficiently reliable and quick for studying the dynamics of cortisol distribution in blood plasma of dairy animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. The kinetics of nonequilibrium chain plasma-chemical oxidation in heterogeneous media

    International Nuclear Information System (INIS)

    Deminskii, M.A.; Potapkin, B.V.; Rusanov, V.D.

    1994-01-01

    The kinetics of oxidation of low-impurity components in air mixtures under heterogeneous conditions was studied. The principal kinetic features of the process were determined on the basis of theoretical analysis of plasma-chemical oxidation in heterogeneous media. The analysis also showed that low concentrations of impurities in liquid aerosol particles can be efficiently oxidized via a chain process induced by reactive species formed in the gas

  11. Pre-hospital transfusion of plasma in hemorrhaging trauma patients independently improves hemostatic competence and acidosis

    DEFF Research Database (Denmark)

    Henriksen, Hanne Herborg; Rahbar, Elaheh; Baer, Lisa A

    2016-01-01

    hypothesized that pre-hospital plasma would improve hemostatic function as evaluated by rapid thrombelastography (rTEG). METHODS: We conducted a prospective observational study recruiting 257 trauma patients admitted to a Level I trauma center having received either blood products pre-hospital or in......BACKGROUND: The early use of blood products has been associated with improved patient outcomes following severe hemorrhage or traumatic injury. We aimed to investigate the influence of pre-hospital blood products (i.e. plasma and/or RBCs) on admission hemostatic properties and patient outcomes. We......-hospital within 6 hours of admission. Clinical data on patient demographics, blood biochemistry, injury severity score and mortality were collected. Admission rTEG was conducted to characterize the coagulation profile and hemostatic function. RESULTS: 75 patients received pre-hospital plasma and/or RBCs (PH group...

  12. Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition

    Science.gov (United States)

    Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae

    2017-12-01

    Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.

  13. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    Science.gov (United States)

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. Blood plasma sample preparation method to determine thyroid hormone-disrupting compounds in Effect-Directed Analysis

    NARCIS (Netherlands)

    Simon, E.; Bytingsvik, J.; Jonker, W.; Leonards, P.E.G.; de Boer, J.; Jenssen, B.M.; Lie, E.; Aars, J.; Hamers, T.H.M.; Lamoree, M.H.

    2011-01-01

    A sample preparation method combining solid-phase extraction (SPE) and liquid-liquid extraction (LLE) was developed to be used in Effect-Directed Analysis (EDA) of blood plasma. Until now such a method was not available. It can be used for extraction of a broad range of thyroid hormone

  15. Effects of imipramine of the orthostatic changes in blood pressure, heart rate and plasma catecholamines

    DEFF Research Database (Denmark)

    Nielsen, J R; Johansen, Torben; Arentoft, A

    1983-01-01

    The effect of imipramine on the orthostatic changes in heart rate, blood pressure and plasma catecholamines were examined in six healthy male subjects on two occasions on high sodium balance (Na+ excretion greater than 120 mmol per day) and on low sodium balance (Na+ excretion less than 110 mmol...... per day), respectively. Orthostatic tests were carried out before and 2 h after ingestion of 150 mg imipramine hydrochloride. Imipramine caused a moderate increase in supine systolic blood pressure, and a pronounced increase in the rise in heart rate, when the subjects assumed erect position...

  16. Knowledge, attitudes and clinical practice of blood products prescribers in Niamey.

    Science.gov (United States)

    Mayaki, Z; Kabo, R; Moutschen, M; Albert, A; Dardenne, N; Sondag, D; Gérard, C

    2016-05-01

    The lack of traceability and monitoring of blood donors and transfused patients constitute a barrier to the most basic rules of haemovigilance and overall good transfusion practices. This study draws up an inventory of knowledge, attitudes and clinical practice of blood prescribers in Niamey. A questionnaire was administered to 180 prescribers of blood products in Niamey in 2011. Questions were related to basic informations on blood transfusion and clinical use of blood. Analyses were performed using SAS 9.3 version. The sample consisted of 180 respondents from several professional categories: 51 physicians (28.33%), 10 medical students (5.56%), 84 nurses (46.67%), 15 anaesthesiologist assistant (8.33%) and 20 midwives (11.11%). Among these, 22.2% received training in blood transfusion safety. Half of the respondents (50.8%) got between 50 and 75% of correct answers, 45.8% got less than 50% correct while 3.35% scored more than 75% correct answers. The overall quality of responses was higher among physicians compared to other prescribers (Ptransfusion safety (Ptransfusion practices is necessary for prescribers of blood products. Accompanying measures to improve transfusion practice must be considered or strengthened through assessments, knowledge update/upgrade (regular, ongoing training) and establishment of active and motivated hospital transfusion committees. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Intraocular pressure, blood pressure, and retinal blood flow autoregulation: a mathematical model to clarify their relationship and clinical relevance.

    Science.gov (United States)

    Guidoboni, Giovanna; Harris, Alon; Cassani, Simone; Arciero, Julia; Siesky, Brent; Amireskandari, Annahita; Tobe, Leslie; Egan, Patrick; Januleviciene, Ingrida; Park, Joshua

    2014-05-29

    This study investigates the relationship between intraocular pressure (IOP) and retinal hemodynamics and predicts how arterial blood pressure (BP) and blood flow autoregulation (AR) influence this relationship. A mathematical model is developed to simulate blood flow in the central retinal vessels and retinal microvasculature as current flowing through a network of resistances and capacitances. Variable resistances describe active and passive diameter changes due to AR and IOP. The model is validated by using clinically measured values of retinal blood flow and velocity. The model simulations for six theoretical patients with high, normal, and low BP (HBP-, NBP-, LBP-) and functional or absent AR (-wAR, -woAR) are compared with clinical data. The model predicts that NBPwAR and HBPwAR patients can regulate retinal blood flow (RBF) as IOP varies between 15 and 23 mm Hg and between 23 and 29 mm Hg, respectively, whereas LBPwAR patients do not adequately regulate blood flow if IOP is 15 mm Hg or higher. Hemodynamic alterations would be noticeable only if IOP changes occur outside of the regulating range, which, most importantly, depend on BP. The model predictions are consistent with clinical data for IOP reduction via surgery and medications and for cases of induced IOP elevation. The theoretical model results suggest that the ability of IOP to induce noticeable changes in retinal hemodynamics depends on the levels of BP and AR of the individual. These predictions might help to explain the inconsistencies found in the clinical literature concerning the relationship between IOP and retinal hemodynamics. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Plasma Assisted Chemical Vapour Deposition – Technological Design Of Functional Coatings

    Directory of Open Access Journals (Sweden)

    Januś M.

    2015-06-01

    Full Text Available Plasma Assisted Chemical Vapour Deposition (PA CVD method allows to deposit of homogeneous, well-adhesive coatings at lower temperature on different substrates. Plasmochemical treatment significantly impacts on physicochemical parameters of modified surfaces. In this study we present the overview of the possibilities of plasma processes for the deposition of diamond-like carbon coatings doped Si and/or N atoms on the Ti Grade2, aluminum-zinc alloy and polyetherketone substrate. Depending on the type of modified substrate had improved the corrosion properties including biocompatibility of titanium surface, increase of surface hardness with deposition of good adhesion and fine-grained coatings (in the case of Al-Zn alloy and improving of the wear resistance (in the case of PEEK substrate.

  19. TK Modeler version 1.0, a Microsoft® Excel®-based modeling software for the prediction of diurnal blood/plasma concentration for toxicokinetic use.

    Science.gov (United States)

    McCoy, Alene T; Bartels, Michael J; Rick, David L; Saghir, Shakil A

    2012-07-01

    TK Modeler 1.0 is a Microsoft® Excel®-based pharmacokinetic (PK) modeling program created to aid in the design of toxicokinetic (TK) studies. TK Modeler 1.0 predicts the diurnal blood/plasma concentrations of a test material after single, multiple bolus or dietary dosing using known PK information. Fluctuations in blood/plasma concentrations based on test material kinetics are calculated using one- or two-compartment PK model equations and the principle of superposition. This information can be utilized for the determination of appropriate dosing regimens based on reaching a specific desired C(max), maintaining steady-state blood/plasma concentrations, or other exposure target. This program can also aid in the selection of sampling times for accurate calculation of AUC(24h) (diurnal area under the blood concentration time curve) using sparse-sampling methodologies (one, two or three samples). This paper describes the construction, use and validation of TK Modeler. TK Modeler accurately predicted blood/plasma concentrations of test materials and provided optimal sampling times for the calculation of AUC(24h) with improved accuracy using sparse-sampling methods. TK Modeler is therefore a validated, unique and simple modeling program that can aid in the design of toxicokinetic studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  1. Adaptation of atomic spectrometric methods for the determination of trace elements in whole blood and blood fractions

    International Nuclear Information System (INIS)

    Prohaska, C.

    2002-05-01

    Analytical methods were developed and optimized for the determination of the elements Ca, Cr, Cu, Fe, Mg, Mn, Se, V and Zn in whole blood and in the blood fractions plasma, erythrocytes and lymphocytes of a group of people suffering from diabetes and of a control group of healthy individuals. Cr, Mn, Se and V were analyzed by ETAAS. Ca, Cu, Fe, Mg and Zn were analyzed by ICP-OES. The status of trace elements in lymphocytes of people suffering from diabetes is changed. Physiologically interesting correlations were observed between the clinical parameters cholesterol, HDL, LDL, blood glucose, HbA1c, age and BMI and the trace element concentrations, e.g. a correlation of blood glucose and HbA1c with selenium in whole blood. An ETAAS - method for the determination of Co and Mo was developed and optimized. The samples were digested applying a mixture of HNO3 and HF, different types of graphite furnaces were tested and a multiple injection technique was applied, thereby enabling a contribution to the normal values of these elements in human whole blood. An on-line coupling of a LC, controlled by FIA, with an ICP-OES was developed to investigate the concentrations of the iron species Fe(II) and Fe(III) and the copper species Cu(I) and Cu(II) in human blood plasma. The ICP-OES instrument was adapted, batch experiments were carried out, oxidizing and reducing agents were added and the acidity of the eluens, the flow rate and the integration time were optimized. Choosing alanine for complexation of the species of interest enables their separation under physiological conditions. In the real plasma samples measured most of the copper and iron was found in their oxidized forms. (author)

  2. Plasma uric acid, creatinine, and urea nitrogen concentrations after whole blood administration via the gastrointestinal tract in domestic pigeons (Columba livia).

    Science.gov (United States)

    Sheldon, Julie; Hoover, John P; Payton, Mark E

    2007-06-01

    To determine if blood administered to pigeons by gavage tube would simulate gastrointestinal hemorrhage in a noncarnivorous avian model, be digested in the gastrointestinal tract, and subsequently alter concentrations of plasma urea nitrogen, creatinine, or uric acid, blood from common peacocks (Pavo cristatus) was administered by gavage tube to 5 healthy domestic pigeons (Columba livia) at doses of 0.5, 1.0, 2.0, 4.0, and 8.0 ml/kg. No significant difference in plasma concentrations of urea nitrogen, creatinine, or uric acid was seen 4-6 hours after gavage. The findings did not support or rule out the presence of gastrointestinal blood in pigeons as a model for hemorrhage in noncarnivorous avian species.

  3. Ambulatory versus home versus clinic blood pressure: the association with subclinical cerebrovascular diseases: the Ohasama Study.

    Science.gov (United States)

    Hara, Azusa; Tanaka, Kazushi; Ohkubo, Takayoshi; Kondo, Takeo; Kikuya, Masahiro; Metoki, Hirohito; Hashimoto, Takanao; Satoh, Michihiro; Inoue, Ryusuke; Asayama, Kei; Obara, Taku; Hirose, Takuo; Izumi, Shin-Ichi; Satoh, Hiroshi; Imai, Yutaka

    2012-01-01

    The usefulness of ambulatory, home, and casual/clinic blood pressure measurements to predict subclinical cerebrovascular diseases (silent cerebrovascular lesions and carotid atherosclerosis) was compared in a general population. Data on ambulatory, home, and casual/clinic blood pressures and brain MRI to detect silent cerebrovascular lesions were obtained in 1007 subjects aged ≥55 years in a general population of Ohasama, Japan. Of the 1007 subjects, 583 underwent evaluation of the extent of carotid atherosclerosis. Twenty-four-hour, daytime, and nighttime ambulatory and home blood pressure levels were closely associated with the risk of silent cerebrovascular lesions and carotid atherosclerosis (all Ppressure values were simultaneously included in the same regression model, each of the ambulatory blood pressure values remained a significant predictor of silent cerebrovascular lesions, whereas home blood pressure lost its predictive value. Of the ambulatory blood pressure values, nighttime blood pressure was the strongest predictor of silent cerebrovascular lesions. The home blood pressure value was more closely associated with the risk of carotid atherosclerosis than any of the ambulatory blood pressure values when home and one of the ambulatory blood pressure values were simultaneously included in the same regression model. The casual/clinic blood pressure value had no significant association with the risk of subclinical cerebrovascular diseases. Although the clinical indications for ambulatory blood pressure monitoring and home blood pressure measurements may overlap, the clinical significance of each method for predicting target organ damage may differ for different target organs.

  4. Sensitivities of selenite, selenate, selenomethionine and trimethylselenonium ion in aqueous solution and in blood plasma - ETAAS compared with ICP-MS

    DEFF Research Database (Denmark)

    Gammelgaard, B.; Larsen, Erik Huusfeldt

    1998-01-01

    coupled plasma mass spectrometry (ICP-MS). Using ETAAS, the sensitivities for Se(IV), SeMet and TMSe in aqueous solution were similar, whereas the sensitivity of Se(VI) was 63% of that value. In blood plasma, the ETAAS sensitivities of Se(IV) and Se(VI) were equal, whereas the sensitivities of Se......Met and TMSe were 87 and 56%, respectively, of that value. In contrast, the ICP-MS sensitivities obtained for Se(VI), TMSe and SeMet were between 96 and 98% of that obtained for Se(IV) in aqueous solution and in blood plasma. It is concluded, that ICP-MS is superior to ETAAS as the problem of differences...... in sensitivity of the selenium species when using ETAAS are not prevalent when using the ICP-MS technique....

  5. 21 CFR 640.60 - Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  6. General practitioner's reported use of clinical guidelines for hypertension and ambulatory blood pressure.

    LENUS (Irish Health Repository)

    Flynn, E

    2012-03-01

    ABPM is an invaluable clinical tool, as it has been shown to improve blood pressure control in primary care. Many clinical guidelines for hypertension advocate ambulatory blood pressure monitoring. This study aims to quantify the use of clinical guidelines for hypertension and to explore the role of ABPM in Primary Care. A questionnaire survey was sent to GPs working in the West of Ireland. 88% (n=139) of GPs use clinical guidelines that recommend the use of ABPM. 82% (n=130) of GPs find use of clinic blood pressure monitoring insufficient for the diagnosis and monitoring of hypertension. Despite good access to ABPM, GPs report lack of remuneration, 72% (n=116), cost 68% (n=108), and lack of time, 51% (n=83) as the main limiting factors to use of ABPM. GPs recognise the clinical value of ABPM, but this study identifies definite barriers to the use of ABPM in Primary Care.

  7. Chemical composition and biological value of spray dried porcine blood by-products and bone protein hydrolysate for young chickens.

    Science.gov (United States)

    Jamroz, D; Wiliczkiewicz, A; Orda, J; Skorupińska, J; Słupczyńska, M; Kuryszko, J

    2011-10-01

    The chemical composition of spray dried porcine blood by-products is characterised by wide variation in crude protein contents. In spray dried porcine blood plasma (SDBP) it varied between 670-780 g/kg, in spray dried blood cells (SDBC) between 830-930 g/kg, and in bone protein hydrolysate (BPH) in a range of 740-780 g/kg. Compared with fish meal, these feeds are poor in Met and Lys. Moreover, in BPH deep deficits of Met, Cys, Thr and other amino acids were found. The experiment comprised 7 dietary treatments: SDBP, SDBC, and BPH, each at an inclusion rate of 20 or 40 g/kg diet, plus a control. The addition of 20 or 40 g/kg of the analysed meals into feeds for very young chickens (1-28 d post hatch) significantly decreased the body weight (BW) of birds. Only the treatments with 40 g/kg of SDBP and SDBC showed no significant difference in BW as compared with the control. There were no significant differences between treatments and type of meal for feed intake, haematocrit and haemoglobin concentrations in blood. Addition of bone protein and blood cell meals to feed decreased the IgG concentration in blood and caused shortening of the femur and tibia bones. However, changes in the mineral composition of bones were not significantly affected by the type of meal used. The blood by-products, which are rich in microelements, improved retention of Ca and Cu only. In comparison to control chickens, significantly better accretion of these minerals was found in treatments containing 20 g/kg of SDBP or 40 g/kg of SDBC. Great variability in apparent ileal amino acid digestibility in chickens was determined. In this respect, some significant differences related to the type of meal fed were confirmed for Asp, Pro, Val, Tyr and His. In general, the apparent ileal digestibility of amino acids was about 2-3 percentage units better in chickens fed on diets containing the animal by products than in control birds.

  8. Measuring the influence of blood component infusion rate on recipient vital signs.

    Science.gov (United States)

    Gehrie, E A; Hendrickson, J E; Tormey, C A

    2015-11-01

    One of the challenges surrounding blood component administration is the determination of an appropriate rate of infusion. There are very few evidence-based guidelines available to guide healthcare providers looking for a 'standard' infusion rate for red blood cells (RBCs), plasma or platelets (PLTs). Our objective was to determine the extent to which blood component infusion rates were associated with changes in transfusion recipient vital signs. We retrospectively examined records of 3496 component infusions (RBCs, n = 2359; PLTs, n = 478; plasma, n = 659) over a 1-year period at a 362-bed multispecialty hospital. The following data were collected for each transfusion: blood product volume and infusion time, recipient pre- and post-transfusion temperature, blood pressure and pulse rate, and hospital ward where transfusion occurred. Plasma (median 10.4 ml/min) was infused faster than PLTs (median 7.2 ml/min, P 20 ml/min) and clinically significant reported changes in vital signs. There does not appear to be a strong correlation between infusion rate and significant changes in recipient temperature, blood pressure or pulse rate. Based on these data, a reasonable rate for routine transfusion is 2-3 ml/min for RBCs and 7-10 ml/min for plasma and PLTs. Faster infusion rates (>20 ml/min) likely can be applied with close patient monitoring if there is a more urgent need for transfusion. © 2015 International Society of Blood Transfusion.

  9. Composition and partition functions of partially ionized hydrogen plasma in Non-Local Thermal Equilibrium (Non-LThE) and Non-Local Chemical Equilibrium (Non-LChE)

    International Nuclear Information System (INIS)

    Chen Kuan; Eddy, T.L.

    1993-01-01

    A GTME (Generalized MultiThermodynamic Equilibrium) plasma model is developed for plasmas in both Non-LThE (Non-Local Thermal Equilibrium) and Non-LChE (Non-Local Chemical Equilibrium). The model uses multitemperatures for thermal nonequilibrium and non-zero chemical affinities as a measure of the deviation from chemical equilibrium. The plasma is treated as an ideal gas with the Debye-Hueckel approximation employed for pressure correction. The proration method is used when the cutoff energy level is between two discrete levels. The composition and internal partition functions of a hydrogen plasma are presented for electron temperatures ranging from 5000 to 35000 K and pressures from 0.1 to 1000 kPa. Number densities of 7 different species of hydrogen plasma and internal partition functions of different energy modes (rotational, vibrational, and electronic excitation) are computed for three affinity values. The results differ from other plasma properties in that they 1) are not based on equilibrium properties; and 2) are expressed as a function of different energy distribution parameters (temperatures) within each energy mode of each species as appropriate. The computed number densities and partition functions are applicable to calculating the thermodynamic, transport, and radiation properties of a hydrogen plasma not in thermal and chemical equilibria. The nonequilibrium plasma model and plasma compositions presented in this paper are very useful to the diagnosis of high-speed and/or low-pressure plasma flows in which the assumptions of local thermal and chemical equilibrium are invalid. (orig.)

  10. Optofluidic Sensor for Inline Hemolysis Detection on Whole Blood

    DEFF Research Database (Denmark)

    Zhou, Chen; Keshavarz Hedayati, Mehdi; Zhu, Xiaolong

    2018-01-01

    Hemolysis is the rupture of red blood cells and constitutes the most common reason for unsuitable blood samples in the clinic. To detect hemolysis, one has to separate the hemoglobin in blood plasma from that in red blood cells. However, current methods entail centrifugation for cell......-time inline detection on whole blood without extra sample preparation like centrifugation. Long-term testing with inline integration in a modified, commercial blood gas analyzer shows high reliability and repeatability of the measurements even with the presence of interference from bilirubin. We envision...... that the present work has large potential in improving diagnosis quality by enabling PoC hemolysis detection in blood gas analyzers and can also lend unique sensing capabilities to other applications dealing with complex turbid media....

  11. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  12. Clinical and prognostic significance of plasma fibrinogen in lung cancer

    Directory of Open Access Journals (Sweden)

    Chen YS

    2014-01-01

    Full Text Available Objectives: Hyperfibrinogenemia is a common problem associated with various carcinomas. The recent studies have shown that high plasma fibrinogen concentration is associated with invasion, growth and metastases of cancer. Furthermore, the recent studies focus on the prognostic significance of fibrinogen in the patients with advanced NSCLC (stage IIIB -IV. However, the prognostic significance of the plasma fibrinogen levels in early stage NSCLC patients (stage I -IIIA still remains unclear. In addition, it remains unclear whether or not chemotherapy-induced changes in fibrinogen level relate to the prognosis. The aims of this study were to 1 further explore the relationship between the plasma fibrinogen concentration and the stage and metastases of lung cancer 2 evaluate the prognostic significance of the basal plasma fibrinogen level in patients with lung cancer 3 explore the prognostic value of the change in fibrinogen levels between pre and post-chemotherapy. Methods: In this retrospective study, the data from 370 patients with lung cancer were enrolled into this study. The plasma fibrinogen levels were compared with the clinical and prognostic significance of lung cancer. The association between the plasma fibrinogen level and clinical-prognostic characteristics were analyzed using SPSS 17.0 software. Results: 1 The median pre-treatment plasma fibrinogen levels were 4.20g/L. Pre-treatment plasma fibrinogen levels correlated significantly with gender (p = 0.013. A higher plasma fibrinogen concentration was associated with squamous cell carcinoma versus adenocarcinoma (4.83±1.50 g/L versus 4.15±1.30 g/L; P<0.001, there was a significant association between plasma fibrinogen level and metastases of lung cancer, pointing a higher plasma fibrinogen level in lymph nodes or distant organ metastases (p < 0.001. 2 Patients with low plasma fibrinogen concentration demonstrates higher overall survival compared with those with high plasma fibrinogen

  13. Sensitive method for the quantitative determination of proguanil and its metabolites in rat blood and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Leveque, Nathalie L; Charman, William N; Chiu, Francis C K

    2006-01-18

    A sensitive, simple and fast liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 1-(4-chlorophenyl)biguanide (4CPB), was developed and validated over a concentration range of 1-2000 ng/mL using only 50 microL of blood or plasma. After a simple solvent precipitation procedure, the supernatant was analysed directly by HPLC-MS/MS. Separation was achieved using an ethyl-linked phenyl reverse phase column with polar endcapping with an acetonitrile-water-formic acid gradient. Mass spectrometry was performed using a triple quadrupole mass spectrometer operating in positive electrospray ionization mode. The elution of PG (254.07-->169.99), CG (252.12-->195.02) and 4CPB (212.06-->153.06) was monitored using selected reaction monitoring. The three compounds and the internal standard (chloroproguanil) were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in blood and plasma. The limit of quantification of PG and CG was 1 ng/mL and 5 ng/mL for 4CPB in rat blood and plasma. The extraction efficiency of PG, CG and 4CPB from rat blood and plasma was higher than 73%. The intra- and inter-assay variability of PG, CG and 4CPB were within 12% and the accuracy within +/-5%. This new assay offers higher sensitivity and a much shorter run time over earlier methods.

  14. Outcome prediction value of determination of cord blood ADM concentrations in neonates with perinatal asphyxia events

    International Nuclear Information System (INIS)

    Zhang Shifa; Zhou Mingxiong; Zhang Xinlu

    2006-01-01

    Objective: To investigate the clinical value of determination of cord blood adrenomedullin (ADM) concentration for predicting development of hypoxic ischemic encephalopathy (HIE) in neonates suffered from perinatal asphyxia. Methods: Cord blood plasma ADM concentrations were measured with RIA in 77 full-ferm neonates with perinatal asphyxia and 30 controls. Results: In the 77 neonates with perinatal asphyxia, 32 developed clinical evidence of HIE within 7 days after birth (HIE group) and 45 didn't (non-HIE group). Cord blood plasma ADM concentrations in the HIE group (160.30 ± 41.3pg/ml) were significantly higher than those in the non-HIE group (112.26 ± 22.90 pg/ml) and controls (102.90 ± 19.43pg/ml). The cord blood plasma ADH concentrations in HIE group were also significantly positively correlated with the severity of the disease (r s = 0. 752, P < 0. 01 ). From our data, taking 117.93pg/ml as cut-off value for diagnosis of HIE would result in a sensitivity of 90.63%, specificity of 80%, and accuracy of 84.42%. Conclusion: High level of ADM in cord blood of neonates with perinatal asphyxia (≥117.93pg/ml) would predict development of HIE with a reasonable accuracy. (authors)

  15. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  16. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil). Centro de Ciencias da Saude]. E-mail: mariaregina.mr@terra.com.br; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2007-09-15

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  17. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  18. Plasma for Electrification of Chemical Industry: a Case Study on CO2 Reduction

    NARCIS (Netherlands)

    van Rooij, G. J.; Akse, H.; Bongers, W.; van de Sanden, M. C. M.

    2018-01-01

    Significantly increasing the share of (intermittent) renewable power in the chemical industry is imperative to meet increasingly stricter limits on CO2 exhaust that are being implemented within Europe. This paper aims to evaluate the potential of a plasma process that converts input CO2 into a pure

  19. Distribution of primaquine in human blood: Drug-binding to alpha 1-glycoprotein

    International Nuclear Information System (INIS)

    Kennedy, E.; Frischer, H.

    1990-01-01

    To clarify the distribution of the antimalarial primaquine in human blood, we measured the drug separately in the liquid, cellular, and ultrafiltrate phases. Washed red cells resuspended at a hematocrit of 0.4 were exposed to a submaximal therapeutic level of 250 ng/ml of carbon 14-labeled primaquine. The tracer was recovered quantitatively in separated plasma and red cells. Over 75% of the total labeled drug was found in red cells suspended in saline solution, but only 10% to 30% in red cells suspended in plasma. The plasma effect was not mediated by albumin. Studies with alpha 1-acid glycoprotein (AGP), tris(2-butoxyethyl)phosphate, an agent that displaces AGP-bound drugs, and cord blood known to have decreased AGP established that primaquine binds to physiologic amounts of the glycoprotein in plasma. Red cell primaquine concentration increased linearly as AGP level fell and as the free drug fraction rose. We suggest that clinical blood levels of primaquine include the red cell fraction or whole blood level because (1) erythrocytic primaquine is a sizable and highly variable component of the total drug in blood; (2) this component reflects directly the free drug in plasma, and inversely the extent of binding to AGP; (3) the amount of free primaquine may influence drug transport into specific tissues in vivo; and (4) fluctuations of AGP, an acute-phase reactant that increases greatly in patients with malaria and other infections, markedly affect the partition of primaquine in blood. Because AGP binds many basic drugs, unrecognized primaquine-drug interactions may exist

  20. Oral Administration of the Japanese Traditional Medicine Keishibukuryogan-ka-yokuinin Decreases Reactive Oxygen Metabolites in Rat Plasma: Identification of Chemical Constituents Contributing to Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Yosuke Matsubara

    2017-02-01

    Full Text Available Insufficient detoxification and/or overproduction of reactive oxygen species (ROS induce cellular and tissue damage, and generated reactive oxygen metabolites become exacerbating factors of dermatitis. Keishibukuryogan-ka-yokuinin (KBGY is a traditional Japanese medicine prescribed to treat dermatitis such as acne vulgaris. Our aim was to verify the antioxidant properties of KBGY, and identify its active constituents by blood pharmacokinetic techniques. Chemical constituents were quantified in extracts of KBGY, crude components, and the plasma of rats treated with a single oral administration of KBGY. Twenty-three KBGY compounds were detected in plasma, including gallic acid, prunasin, paeoniflorin, and azelaic acid, which have been reported to be effective for inflammation. KBGY decreased level of the diacron-reactive oxygen metabolites (d-ROMs in plasma. ROS-scavenging and lipid hydroperoxide (LPO generation assays revealed that gallic acid, 3-O-methylgallic acid, (+-catechin, and lariciresinol possess strong antioxidant activities. Gallic acid was active at a similar concentration to the maximum plasma concentration, therefore, our findings indicate that gallic acid is an important active constituent contributing to the antioxidant effects of KBGY. KBGY and its active constituents may improve redox imbalances induced by oxidative stress as an optional treatment for skin diseases.