WorldWideScience

Sample records for blood count

  1. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  2. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  3. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  4. Ancestry informative markers and complete blood count parameters in Brazilian blood donors

    Directory of Open Access Journals (Sweden)

    Gabriela E. S. Felix

    Full Text Available A complete blood count is very useful in clinical diagnoses when reference ranges are well established for the population. Complete blood counts and allele frequencies of Ancestry Informative Markers (AIMs were analyzed in Brazilians with the aim of characterizing the hematological values of an admixed population. Positive associations were observed between gender and neutrophils, monocytes, eosinophils, erythrocytes, hemoglobin, hematocrit, MCV, MCHC and platelet counts. No significant differences were found for age, alcohol consumption, educational status, ethnicity, smoking in respect to the complete blood count values. In general, men had higher red blood cell values, while women had higher values for white blood cells and platelets. The study of the population was highly heterogeneous with mean proportions (± SE of African, European and Amerindian ancestry being 49.0 ± 3.0%, 44.0 ± 9.0% and 7.0 ± 9.0%, respectively. Amerindian ancestry showed limited contribution to the makeup of the population, but estimated ancestral proportions were statistically significant (r = 0.9838; P<0.001. These hematologic values are similar to Afro-Americans, another admixed population.

  5. Association of Blood Eosinophil and Blood Neutrophil Counts with Asthma Exacerbations in the Copenhagen General Population Study

    DEFF Research Database (Denmark)

    Vedel-Krogh, Signe; Nielsen, Sune Fallgaard; Lange, Peter

    2017-01-01

    BACKGROUND: Blood eosinophil count is a marker of eosinophilic airway inflammation and disease severity in asthma. However, blood neutrophil count might also be associated with disease severity. We tested the hypothesis that high blood eosinophil and neutrophil counts are both associated...... with the risk of asthma exacerbations among individuals with asthma from the general population. METHODS: From the Copenhagen General Population Study with 81351 participants, we included 4838 with self-reported asthma. We recorded baseline blood eosinophil and neutrophil counts, and asthma exacerbations during...... with blood eosinophil counts >0.29 × 10(9)/L (highest tertile) vs individuals with blood eosinophil counts

  6. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  7. [Complete blood count reference values of donated cord blood from Korean neonates].

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Kim, Byoung Jae; Hwang, Kyu Ri; Kim, Jin Ju; Roh, Eun Youn

    2009-06-01

    In the public cord blood (CB) banks, only safe CB units with adequate cell doses are processed and stored. Complete blood count (CBC) of CB is crucial for estimating total nucleated cells (TNC) and screening suitable CB units without hematologic abnormalities. We analyzed CBC parameters of the donated CB from healthy Korean neonates to establish CBC reference values. A total of 2,129 Korean CB units, donated and processed during the period from August 2007 to December 2007, were enrolled. We measured hemoglobin (Hb), white blood cell (WBC) count, differential count of WBC, platelets and nucleated red blood cell (nRBC) count by XE-2100 automated hematology analyzer (Sysmex, Japan), and estimated reference value of each parameter by using parametric (Mean+/-2SD) and/or non-parametric methods (2.5-97.5 percentile). And also, we compared the result of each parameter in relation to sex of neonates and delivery method. Because the differences of CBC values among different subgroups were not remarkable, we established the reference intervals as follows without subgroup division: Hb, 9.0-14.4 g/dL; WBC count, 5.6-18.5 x 10(3)/microL; differential count of WBC (neutrophils, 40.8-72.4%; lymphocytes, 17.2-46.7%; monocytes, 4.9-12.8%; eosinophils, 0.7-7.0%; basophils, 0.0-1.6%); platelet, 130-287 x 10(3)/microL; nRBCs, 0.0-13.1/100 WBC. We established cord blood CBC reference values of healthy Korean neonates using a large-scale CB units. The established CBC reference values from our study will be useful as basic data for CBC interpretation and assessment of transplant suitability of donated CB.

  8. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    Science.gov (United States)

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  9. Low white blood cell count and cancer

    Science.gov (United States)

    ... gov/ency/patientinstructions/000675.htm Low white blood cell count and cancer To use the sharing features on this page, please enable JavaScript. White blood cells (WBCs) fight infections from bacteria, viruses, fungi, and ...

  10. White blood cell counting analysis of blood smear images using various segmentation strategies

    Science.gov (United States)

    Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.

  11. White Blood Cell Counts and Malaria

    National Research Council Canada - National Science Library

    McKenzie, F. E; Prudhomme, Wendy A; Magill, Alan J; Forney, J. R; Permpanich, Barnyen; Lucas, Carmen; Gasser, Jr., Robert A; Wongsrichanalai, Chansuda

    2005-01-01

    White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999...

  12. Relationship of blood and milk cell counts with mastitic pathogens in Murrah buffaloes

    Directory of Open Access Journals (Sweden)

    C. Singh

    2010-02-01

    Full Text Available The present study was undertaken to see the effect of mastitic pathogens on the blood and milk counts of Murrah buffaloes. Milk and blood samples were collected from 9 mastitic Murrah buffaloes. The total leucocyte Counts (TLC and Differential leucocyte counts (DLC in blood were within normal range and there was a non-significant change in blood counts irrespective of different mastitic pathogens. Normal milk quarter samples had significantly (P<0.01 less Somatic cell counts (SCC. Lymphocytes were significantly higher in normal milk samples, whereas infected samples had a significant increase (P<0.01 in milk neutrophils. S. aureus infected buffaloes had maximum milk SCC, followed by E. coli and S. agalactiae. Influx of neutrophils in the buffalo mammary gland was maximum for S. agalactiae, followed by E.cli and S. aureus. The study indicated that level of mastitis had no affect on blood counts but it influenced the milk SCC of normal quarters.

  13. Effect of exercise on erythrocyte count and blood activity concentration after technetium-99m in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstom, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    The effects of exercise on blood radiotracer concentration after technetium-99m in vivo red blood cell labeling was studied. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased in erythrocyte count (r=0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. It was concluded that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  14. The counting of native blood cells by digital microscopy

    Science.gov (United States)

    Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.

    2017-03-01

    An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.

  15. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  16. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    Science.gov (United States)

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (Ppregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  17. Impact of valproates on haemostasis and blood cell count in children

    Directory of Open Access Journals (Sweden)

    Igrutinović Zoran

    2008-01-01

    Full Text Available INTRODUCTION Epilepsy is a highly prevalent disease affecting 0.5-1.5% of the world's population. One of the most frequently used antiepileptics are valproates. These medicines show a negative impact on haemostasis and peripheral blood count. OBJECTIVE The objective of the study was to examine the negative impact of valproates on haemostasis and peripheral blood count in children and to analyse whether these disturbances were dependent on the dosage of valproates and drug level in blood. METHOD A two-year research was conducted. The research included: 35 children using valproates, 12 children using the therapy of both valproates and carbamazepine and 30 healthy children. Complete peripheral blood count, screening tests of haemostasis (bleeding time, prothrombin time, prothrombin ratio, activated partial thromboplastin time, fibrinogen and capacity of thrombocyte aggregation research were done in all the children. RESULTS We found significantly more common frequency of leukopenia and neutropenia in children using valproates in comparison with the healthy children group. We also found the more common frequency of eosinophilia in comparison with healthy children. The children with the valproate therapy have lower approximate values of the number of platelets, fibrinogen and platelet aggregation in comparison with healthy children, but they have a higher approximate value of bleeding time and prothrombin time. These disturbances are in correlation with the dosage and the level of the medicine in blood. CONCLUSION Valproates have a negative effect on certain blood count parameters and haemostasis in children. Drug dosage and blood drug level are correlated with their negative impact on haemostasis parameters.

  18. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  19. Effect of exercise on erythrocyte count and blood activity concentration after /sup 99m/Tc in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstam, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    We studied the effect of exercise on blood radiotracer concentration after /sup 99m/Tc in vivo red blood cell labeling. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased during exercise in all 13 subjects. Percent increase in activity correlated with percent increase in erythrocyte count (r . -0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. We conclude that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  20. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  1. Microfluidic Cytometer for Complete Blood Count Analysis, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We will fabricate and test microfluidic designs for a micro-electromechanical system based complete blood count (CBC) analysis in separate modules and integrate them...

  2. Nucleated red blood cells count in pregnancies with idiopathic intra-uterine growth restriction.

    Directory of Open Access Journals (Sweden)

    Fatemeh Davari-Tanha

    2014-06-01

    Full Text Available Elevated nucleated red blood cell (NRBC count is introduced as a potential marker of intra-uterine growth restriction (IUGR. To investigate the probable association regardless of any known underlying disease, we aimed to study disturbances in NRBC count in infants experiencing idiopathic IUGR.Twenty three infants regarded IUGR without any known cause were chosen to be compared to 48 normal neonates. Blood samples were collected instantly after birth and the same measurements were done in both groups.NRBC count/100 white blood cells was significantly higher in the IUGR group (P value < 0.001. pH measurements did not reveal any significant difference.Increased NRBC count in cases of idiopathic IUGR in absence of chronic hypoxia could strengthen its predictive value suggested in previous studies. It could help early IUGR detection and beneficial intervention.

  3. Microfluidic Cytometer for Complete Blood Count Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — RMD proposes to develop a MEMS based complete blood count (CBC) instrument that can be used aboard a spacecraft. We will produce a microfluidic scale combination...

  4. Diagnostic value of inflammatory markers (complete blood count ...

    African Journals Online (AJOL)

    Objective The aim of the study was to evaluate the diagnostic value of inflammatory markers [complete blood cell count (CBC), erythrocyte sedimentation rate (ESR),. C-reactive protein (CRP)] for the differentiation of acute appendicitis from nonspecific abdominal pain in children. Patients and methods In this prospective ...

  5. Diagnostic value of inflammatory markers (complete blood count ...

    African Journals Online (AJOL)

    Objective The aim of the study was to evaluate the diagnostic value of inflammatory markers [complete blood cell count (CBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP)] for the differentiation of acute appendicitis from nonspecific abdominal pain in children. Patients and methods In this prospective ...

  6. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  7. The investigation of complete blood counting parameters in deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet Çalışkan

    2014-03-01

    Full Text Available Objective: The role of inflammation in the deep venous thrombosis (DVT process has been explained in various studies. Hence, the role of inflammatory markers in this illness has been researched previouslyin the literature. Recent years, such as parameters, neutrophil lymphocyte ratio (NLR and platelet lymphocyte ratio (PLR, among complete blood count have been frequently started to use as an expression of inflammatory marker. In the current study, the relation between complete blood count parameters and DVT was investigated. Methods: 50 patients admitted to our clinic with the diagnosis of acute DVT (28 female, 22 male were included in the study. The patients were diagnosed by clinical symptoms and Doppler USG. Patients with additional illness that can form an inflammatory response were excluded. 30 healthy volunteers were included as a control group. Routine complete blood counts of these patients were examined retrospectively. Routine complete blood counts and nonselective inflammatory markers, red cell distribution width (RDW, white cells (WBC, NLR, and PLR measurements were examined statistically. Results: The mean age of patients included in study was 46.2±14.2 and 53% of them were female. When the groups were examined in terms of hematological parameters, lymphocyte (2.6±0.8 and 2.1±0.7, p=0.003 and platelet (322±144 and 264±66, p=0.042 values were detected to be higher. Hemoglobin (13.2±2.0 and 14.6±1.5, p=0.002 and hematocrit (38.7±5.1 and 42.8±6.9, p<0.001 values were detected to be less while the WBC, neutrophil, NLR, RDW and PLR were similar. Regarding the two groups with and without anticoagulant therapy, in the DVT group, there were no significant differences detected in terms of age, gender, and hematological parameters. Conclusion: In this study, there were no significant differences between healthy volunteers blood count parameters of patients taken into consideration with pure DVT. There is no significant change shown.

  8. Complete Blood Count Reference Intervals for Healthy Han Chinese Adults

    Science.gov (United States)

    Mu, Runqing; Guo, Wei; Qiao, Rui; Chen, Wenxiang; Jiang, Hong; Ma, Yueyun; Shang, Hong

    2015-01-01

    Background Complete blood count (CBC) reference intervals are important to diagnose diseases, screen blood donors, and assess overall health. However, current reference intervals established by older instruments and technologies and those from American and European populations are not suitable for Chinese samples due to ethnic, dietary, and lifestyle differences. The aim of this multicenter collaborative study was to establish CBC reference intervals for healthy Han Chinese adults. Methods A total of 4,642 healthy individuals (2,136 males and 2,506 females) were recruited from six clinical centers in China (Shenyang, Beijing, Shanghai, Guangzhou, Chengdu, and Xi’an). Blood samples collected in K2EDTA anticoagulant tubes were analyzed. Analysis of variance was performed to determine differences in consensus intervals according to the use of data from the combined sample and selected samples. Results Median and mean platelet counts from the Chengdu center were significantly lower than those from other centers. Red blood cell count (RBC), hemoglobin (HGB), and hematocrit (HCT) values were higher in males than in females at all ages. Other CBC parameters showed no significant instrument-, region-, age-, or sex-dependent difference. Thalassemia carriers were found to affect the lower or upper limit of different RBC profiles. Conclusion We were able to establish consensus intervals for CBC parameters in healthy Han Chinese adults. RBC, HGB, and HCT intervals were established for each sex. The reference interval for platelets for the Chengdu center should be established independently. PMID:25769040

  9. Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting

    Directory of Open Access Journals (Sweden)

    Xiwei Huang

    2016-11-01

    Full Text Available A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT. However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR and Convolutional Neural Network based SR (CNNSR. Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications.

  10. Evidence for significant influence of host immunity on changes in differential blood count during malaria.

    Science.gov (United States)

    Berens-Riha, Nicole; Kroidl, Inge; Schunk, Mirjam; Alberer, Martin; Beissner, Marcus; Pritsch, Michael; Kroidl, Arne; Fröschl, Günter; Hanus, Ingrid; Bretzel, Gisela; von Sonnenburg, Frank; Nothdurft, Hans Dieter; Löscher, Thomas; Herbinger, Karl-Heinz

    2014-04-23

    Malaria has been shown to change blood counts. Recently, a few studies have investigated the alteration of the peripheral blood monocyte-to-lymphocyte count ratio (MLCR) and the neutrophil-to-lymphocyte count ratio (NLCR) during infection with Plasmodium falciparum. Based on these findings this study investigates the predictive values of blood count alterations during malaria across different sub-populations. Cases and controls admitted to the Department of Infectious Diseases and Tropical Medicine from January 2000 through December 2010 were included in this comparative analysis. Blood count values and other variables at admission controlled for age, gender and immune status were statistically investigated. The study population comprised 210 malaria patients, infected with P. falciparum (68%), Plasmodium vivax (21%), Plasmodium ovale (7%) and Plasmodium malariae (4%), and 210 controls. A positive correlation of parasite density with NLCR and neutrophil counts, and a negative correlation of parasite density with thrombocyte, leucocyte and lymphocyte counts were found. An interaction with semi-immunity was observed; ratios were significantly different in semi-immune compared to non-immune patients (P value of the ratios was fair but limited. However, these changes were less pronounced in patients with semi-immunity. The ratios might constitute easily applicable surrogate biomarkers for immunity.

  11. Lower white blood cell counts in elite athletes training for highly aerobic sports.

    Science.gov (United States)

    Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J

    2010-11-01

    White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.

  12. Fetal blood vessel count increases in compensation of hypoxia in premature placentas

    Directory of Open Access Journals (Sweden)

    K. Kartini

    2015-04-01

    Full Text Available Background Prematurity refers to live births before 37 weeks of gestation, wherein the baby is born before the body and its organ systems achieve perfect maturity, and this disorder is still a global problem. The high incidence of prematurity is a problem in developing and also in developed countries. Certain conditions accompanying pregnancies like preeclampsia, infection, and placental insufficiency, may trigger uterine hypoxia, causing premature birth. The placental condition is related to the intra-uterine fetal condition. In prolonged placental hypoxia, there occurs a compensatory mechanism, i.e. an increase in placental angiogenesis. This study aimed to evaluate the effect of hypoxia on fetal blood vessel count as compensatory mechanism for tissue hypoxia. Methods An observational-analytical cross-sectional design using paraffin blocks of conserved premature placentas, comprising 31 samples of hypoxic premature placentas and 28 samples of non-hypoxic premature placentas, selected using non-random consecutive sampling. The samples were made into slides and stained with hematoxylin-eosin for assessment of histological structure, including fetal blood vessel count and integrity, villus conditions, syncytiotrophoblastic nuclear changes, and syncytiotrophoblastic nuclear aggregation. Mann-Whitney test was used to compare the difference of blood vessel count between groups. Results Assessment of histological structure showed a significant increase in fetal blood vessel count in the hypoxic group [8.00 (5-15] as compared with the non-hypoxic group [7.50 (3-15]. Conclusion The hypoxia in premature placentas caused an increase in the number of fetal blood vessels as a form of compensation for disturbed oxygen homeostasis.

  13. Fetal blood vessel count increases in compensation of hypoxia in premature placentas

    Directory of Open Access Journals (Sweden)

    K Kartini

    2016-02-01

    Full Text Available BACKGROUND Prematurity refers to live births before 37 weeks of gestation, wherein the baby is born before the body and its organ systems achieve perfect maturity, and this disorder is still a global problem. The high incidence of prematurity is a problem in developing and also in developed countries. Certain conditions accompanying pregnancies like preeclampsia, infection, and placental insufficiency, may trigger uterine hypoxia, causing premature birth. The placental condition is related to the intra-uterine fetal condition. In prolonged placental hypoxia, there occurs a compensatory mechanism, i.e. an increase in placental angiogenesis. This study aimed to evaluate the effect of hypoxia on fetal blood vessel count as compensatory mechanism for tissue hypoxia. METHODS An observational-analytical cross-sectional design using paraffin blocks of conserved premature placentas, comprising 31 samples of hypoxic premature placentas and 28 samples of non-hypoxic premature placentas, selected using non-random consecutive sampling. The samples were made into slides and stained with hematoxylin-eosin for assessment of histological structure, including fetal blood vessel count and integrity, villus conditions, syncytiotrophoblastic nuclear changes, and syncytiotrophoblastic nuclear aggregation. Mann-Whitney test was used to compare the difference of blood vessel count between groups. RESULTS Assessment of histological structure showed a significant increase in fetal blood vessel count in the hypoxic group [8.00 (5-15] as compared with the non-hypoxic group [7.50 (3-15]. CONCLUSION The hypoxia in premature placentas caused an increase in the number of fetal blood vessels as a form of compensation for disturbed oxygen homeostasis.

  14. Effect of fractionated regional external beam radiotherapy on peripheral blood cell count

    International Nuclear Information System (INIS)

    Zachariah, B.; Jacob, S.S.; Gwede, C.; Cantor, A.; Patil, J.; Casey, L.; Zachariah, A.B.

    2001-01-01

    Purpose: The purpose of this study was to assess the need for obtaining weekly complete blood count (CBC) values and to identify the pattern of changes in CBC during regional conventional fractionated radiotherapy. Methods and Materials: A retrospective analysis of CBC data on 299 adult cancer patients who received definitive conventional radiotherapy to head and neck (n=95), chest (n=96), and pelvis (n=108) was performed. Temporal patterns and magnitude of change in white blood cells, neutrophils, lymphocytes, and platelets during radiotherapy were examined. Results: There were statistically significant declines in all counts, albeit not clinically significant. Notable differences between disease sites were found. The greatest weekly interval change in counts occurred during the first week of radiotherapy for all groups of patients. The mean WBC nadir values during treatment were 5.8 for head and neck, 6.8 for chest, and 5.4 for pelvis. The nadirs for all counts occurred toward the middle-to-end of radiotherapy. Lymphocytes were found to be more sensitive to radiotherapy than other leukocyte subcomponents. Conclusion: Our study suggests that weekly CBC monitoring is not necessary for all patients undergoing standard fractionated radiotherapy. Baseline blood counts may be used to determine an optimal schedule for monitoring CBCs in patients receiving conventional radiation alone. Reduced monitoring of CBC may result in significant financial savings

  15. Effect of interval training program on white blood cell count in the ...

    African Journals Online (AJOL)

    Objective: Elevated white blood cell (WBC) count is considered to be prospectively and positively associated with cardiovascular diseases, particularly hypertension. Also, the positive role of exercise in the management of hypertension has been well and long established. However the relationship between WBC count and ...

  16. Establishment of new complete blood count reference values for healthy Thai adults.

    Science.gov (United States)

    Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O

    2018-04-28

    Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.

  17. Point-of-care blood eosinophil count in a severe asthma clinic setting.

    Science.gov (United States)

    Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio

    2017-07-01

    One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2  = 0.854, P asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  18. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  19. THE EFFECT OF BLOOD AND MILK SERUM ZINC CONCENTRATION ON MILK SOMATIC CELL COUNT IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Ivana Davidov

    2016-11-01

    Full Text Available The objective of this study was to evaluate the effect of blood and milk zinc concentration on somatic cell count and occurrence of subclinical mastitis cases. The study was performed on thirty Holstein cows approximate same body weight, ages 3 to 5 years, with equally milk production. Blood samples were taken after the morning milking from the caudal vein and milk from all four quarters was taken before morning milking. All samples of blood and milk were taken to determined zinc, using inductively coupled plasma mass spectrometry. 37.67% (11/30 cows have blood serum zinc concentration below 7µmol/l, and 63.33% or 19/30 cows have blood serum zinc concentration higher then 13µmol/l. Also 30% (9/30 cows have somatic cell count lower then 400.000/ml which indicate absence of subclinical mastitis, but 70% (21/30 cows have somatic cell count higher then 400.000/ml which indicate subclinical mastitis. Results indicate that cows with level of zinc in blood serum higher then 13 µmol/l have lower somatic cell count. Cows with lower zinc blood serum concentration then 7 µmol/l have high somatic cell count and high incidence of subclinical mastitis. According to results in this research there is no significant effect of milk serum zinc concentration on somatic cell count in dairy cows.

  20. 21 CFR 864.6160 - Manual blood cell counting device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160 Section 864.6160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6160 Manual...

  1. Predictive Value of Nucleated Red Blood Cell Counts in Cord and Peripheral Blood of Asphyxiated Term Neonates in the First Week of Life

    Directory of Open Access Journals (Sweden)

    B Bahman Bijari

    2010-03-01

    Full Text Available Introduction: Increased numbers of nucleated red blood cells (NRBC circulating in the blood of neonates can be associated with relative hypoxia and adverse outcomes. Thus, the aim of this study was to assess the NRBC count during the first week of life in neonates diagnosed with asphyxia as compared to healthy neonates and to determine the short-term morbidity and mortality for the affected babies. Methods: The cross-sectional study compared 15 healthy neonates with 15 neonates diagnosed with asphyxia confirmed by pH of cord blood or Apgar scores. The nucleated red blood cell (NRBC counts were calculated right after birth, and on days 3 and 7, and the hematological parameters of umbilical cord blood were also evaluated. The infants were followed for mortality and associated morbidity. Statistical analysis was conducted using the Mann-Whitney U test, analysis of variance, chi-square tests, and Pearson’s correlation coefficient. A p-value < 0.05 was considered as statistically significant. Results: The initial NRBC counts were significantly higher in the asphyxiated group than in the control group and the difference remained significant through the end of first week. All of the umbilical cord blood parameters were significantly lower in the study group and were negatively correlated with the NRBC count. At birth, higher NRBC count correlated with higher mortality. conclution: Results show that NRBC count is a useful predictive factor for neonatal asphyxia through the end of the first week of life, although a larger study population and a longer follow up period seems to be necessary.

  2. Repair of changes in peripheral blood count of rats after chronic irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chlebovsky, O; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes are described in the peripheral blood count of rats irradiated during 120 days with doses of 95.7, 191.4, 258.4, 344.5 and 507.2 mGy/day; during 15 days with a dose of 1004.8 mGy and examined till the 180th day after termination of irradiation. The course of repair can be divided into two phases, namely: phase 1 till the 40th day after termination of irradiation when leukocyte and platelet counts reach approximately 50% of control values; this phase lasts until the 100th day after cessation of irradiation; phase 2 from the 100th till the 180th day when these peripheral blood element counts attain the level of control values. Thus in the stated conditions of irradiation, 150 to 180 days are required for radiation damage to the hemopoietic system to repair.

  3. Nutritionally-related blood metabolites and faecal egg counts in ...

    African Journals Online (AJOL)

    Nutritionally-related blood metabolites and faecal egg counts in indigenous Nguni goats of South Africa. ... It, therefore, is imperative to put measures in place to counteract the drop in any of these parameters, with season, if productivity of the indigenous goats is to be maintained. Further studies are required to determine the ...

  4. Microfluidic cartridges for automated, point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2016-11-01

    Full Text Available Disposable, low-cost microfluidic cartridges for automated blood cell counting applications are presented in this article. The need for point-of-care medical diagnostic tools is evident, particularly in low-resource and rural settings, and a full...

  5. Detection of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa)

    Science.gov (United States)

    Ekawati, ER; Yusmiati, S. N. H.

    2018-01-01

    Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.

  6. Cells identification and counting in blood native state on the basis of digital microscopy.

    Directory of Open Access Journals (Sweden)

    Doubrovski V.A.

    2016-12-01

    Full Text Available The research goal is to develop an algorithm for the processing of photo images of native blood samples to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cell samples. Materials and Methods. The objects of investigation were the samples of the whole donated blood, diluted 400 times by saline. Special "photo templates", the effect of "highlighting" of leukocytes, which was detect by authors, and the resolution of platelets from leukocytes by the areas of their photo images were suggested for identification of the cells. Results. 80 photo images of native blood solutions were selected for computer processing, while the total number of cells counted was: erythrocytes — 4184, platelets — 292 and leukocytes — 84, total — 4560 blood cells. Comparison of the results achieved with ones obtained by "manual" account or by the device for formed elements counting Sysmex XT-400i gives satisfactory results. Conclusion. It is shown that the accuracy of counting of the native blood cells may be comparable with the accuracy of similar studies by means of smears. At the same time the proposed analysis of native blood simplifies greatly the samples preparation in comparison to smears, permits to move from the detection of blood cells ratios to the determination of their concentrations in the sample.

  7. Early Colorectal Cancer Detected by Machine Learning Model Using Gender, Age, and Complete Blood Count Data.

    Science.gov (United States)

    Hornbrook, Mark C; Goshen, Ran; Choman, Eran; O'Keeffe-Rosetti, Maureen; Kinar, Yaron; Liles, Elizabeth G; Rust, Kristal C

    2017-10-01

    Machine learning tools identify patients with blood counts indicating greater likelihood of colorectal cancer and warranting colonoscopy referral. To validate a machine learning colorectal cancer detection model on a US community-based insured adult population. Eligible colorectal cancer cases (439 females, 461 males) with complete blood counts before diagnosis were identified from Kaiser Permanente Northwest Region's Tumor Registry. Control patients (n = 9108) were randomly selected from KPNW's population who had no cancers, received at ≥1 blood count, had continuous enrollment from 180 days prior to the blood count through 24 months after the count, and were aged 40-89. For each control, one blood count was randomly selected as the pseudo-colorectal cancer diagnosis date for matching to cases, and assigned a "calendar year" based on the count date. For each calendar year, 18 controls were randomly selected to match the general enrollment's 10-year age groups and lengths of continuous enrollment. Prediction performance was evaluated by area under the curve, specificity, and odds ratios. Area under the receiver operating characteristics curve for detecting colorectal cancer was 0.80 ± 0.01. At 99% specificity, the odds ratio for association of a high-risk detection score with colorectal cancer was 34.7 (95% CI 28.9-40.4). The detection model had the highest accuracy in identifying right-sided colorectal cancers. ColonFlag ® identifies individuals with tenfold higher risk of undiagnosed colorectal cancer at curable stages (0/I/II), flags colorectal tumors 180-360 days prior to usual clinical diagnosis, and is more accurate at identifying right-sided (compared to left-sided) colorectal cancers.

  8. The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate.

    Science.gov (United States)

    Sakashita, Araci M; Kondo, Andrea T; Yokoyama, Ana Paula H; Lira, Sanny M C; Bub, Carolina B; Souza, Aline M; Cipolletta, Andrea N F; Alvarez, Kelen C; Hamerschlak, Nelson; Kutner, Jose M; Chiattone, Carlos S

    2018-01-19

    Autologous peripheral blood hematopoietic stem cell (PBSC) collection efficiency (CE) is reportedly affected by the patient's blood properties; however, studies to identify factors correlated with CE have shown inconsistent results. Additionally, variables such as stem cell graft granulocyte content and patient age, sex, and underlying disease, may be associated with hematopietic stem cell (HSC) infusion-related adverse reactions. In this study, we evaluated the correlation of preleukapheresis PB granulocyte count and PBSC harvest variables with CD34 + collection yield and efficiency, and thawed HSC infusion side effect occurrence. We evaluated data from 361 patients who had undergone autologous PBSC transplant. Large volume leukapheresis was the method for PBSC collection. Complete Blood Count and CD34 + cell enumeration were performed in the preapheresis PB and the apheresis product sample. The PBSC grafts were submitted to non-controlled rate freezing after addition of 5% DMSO plus 6% hidroxyethylstarch as a cryoprotectant solution. The cryopreserved graft was thawed in a 37°C water bath and then infused without further manipulation. The CD34 + yield was associated with preapheresis PB CD34 + count and immature granulocyte count. The PBSC CE was negatively correlated with preapheresis white blood cell (WBC), immature granulocyte and granulocyte count. The leukapheresis product total nucleated cell (TNC) and granulocyte content was correlated with the thawed graft infusion side effect occurrence. This study has shown that preapheresis PB WBC and granulocyte counts were associated with leukapheresis CE. Additionally, the leukapheresis product TNC and granulocyte content was correlated with thawed graft infusion side effect occurrence. © 2018 Wiley Periodicals, Inc.

  9. A Novel Automated Slide-Based Technology for Visualization, Counting, and Characterization of the Formed Elements of Blood: A Proof of Concept Study.

    Science.gov (United States)

    Winkelman, James W; Tanasijevic, Milenko J; Zahniser, David J

    2017-08-01

    - A novel automated slide-based approach to the complete blood count and white blood cell differential count is introduced. - To present proof of concept for an image-based approach to complete blood count, based on a new slide preparation technique. A preliminary data comparison with the current flow-based technology is shown. - A prototype instrument uses a proprietary method and technology to deposit a precise volume of undiluted peripheral whole blood in a monolayer onto a glass microscope slide so that every cell can be distinguished, counted, and imaged. The slide is stained, and then multispectral image analysis is used to measure the complete blood count parameters. Images from a 600-cell white blood cell differential count, as well as 5000 red blood cells and a variable number of platelets, that are present in 600 high-power fields are made available for a technologist to view on a computer screen. An initial comparison of the basic complete blood count parameters was performed, comparing 1857 specimens on both the new instrument and a flow-based hematology analyzer. - Excellent correlations were obtained between the prototype instrument and a flow-based system. The primary parameters of white blood cell, red blood cell, and platelet counts resulted in correlation coefficients (r) of 0.99, 0.99, and 0.98, respectively. Other indices included hemoglobin (r = 0.99), hematocrit (r = 0.99), mean cellular volume (r = 0.90), mean corpuscular hemoglobin (r = 0.97), and mean platelet volume (r = 0.87). For the automated white blood cell differential counts, r values were calculated for neutrophils (r = 0.98), lymphocytes (r = 0.97), monocytes (r = 0.76), eosinophils (r = 0.96), and basophils (r = 0.63). - Quantitative results for components of the complete blood count and automated white blood cell differential count can be developed by image analysis of a monolayer preparation of a known volume of peripheral blood.

  10. Long-term health effects of thorium compounds on exposed workers: the complete blood count

    International Nuclear Information System (INIS)

    Conibear, S.A.

    1981-01-01

    Two hundred seventy-three men exposed to thorium and other rare earths between 1940 and 1973 at a plant which refined monazite sand were studied at Argonne National Laboratory from 1976 to 1980. In vivo measurements of body burden were made by counting gamma rays emitted by daughter products of retained thorium and by measuring exhaled thoron. Health status was ascertained through questionnaire, physical examination, and clinical laboratory tests. Measured body burden was found to be higher in those with a history of longer exposure. All parameters of the complete blood count were examined for evidence of an effect due to thorium. Comparisons of high and low body burden groups showed that only age and cigarette smoking had an effect on complete blood count parameters

  11. Adaptive and automatic red blood cell counting method based on microscopic hyperspectral imaging technology

    Science.gov (United States)

    Liu, Xi; Zhou, Mei; Qiu, Song; Sun, Li; Liu, Hongying; Li, Qingli; Wang, Yiting

    2017-12-01

    Red blood cell counting, as a routine examination, plays an important role in medical diagnoses. Although automated hematology analyzers are widely used, manual microscopic examination by a hematologist or pathologist is still unavoidable, which is time-consuming and error-prone. This paper proposes a full-automatic red blood cell counting method which is based on microscopic hyperspectral imaging of blood smears and combines spatial and spectral information to achieve high precision. The acquired hyperspectral image data of the blood smear in the visible and near-infrared spectral range are firstly preprocessed, and then a quadratic blind linear unmixing algorithm is used to get endmember abundance images. Based on mathematical morphological operation and an adaptive Otsu’s method, a binaryzation process is performed on the abundance images. Finally, the connected component labeling algorithm with magnification-based parameter setting is applied to automatically select the binary images of red blood cell cytoplasm. Experimental results show that the proposed method can perform well and has potential for clinical applications.

  12. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  13. Association between red blood cell indices and CD4 count in HIV-positive reproductive women

    Science.gov (United States)

    Lumbanraja, S. N.; Siregar, D. I. S.

    2018-03-01

    Red blood cell indices, hemoglobin, and hematocrit reflect rapidity of HIV disease progression. This study aims to determine red blood cell indices and CD4 count in HIV-positive reproductive women. This study was a cross sectional study conducted at AIDS outpatient clinic at Haji Adam Malik General Hospital, Medan Indonesia. All seropositive reproductive women within antiretroviral therapy consented for blood count and CD4 examination. Data were collected and analyzed with SPSS 19. In subjects with CD4≤350 mm3, mean hemoglobin was 10.95 ± 2.01, hematocrit was 31.83 ± 5.04%, MCV was 84.17 ± 11.41, MCH was 25.98 ± 2.65, and MCHC was 32.18 ± 2.17. Mean hemoglobin, hematocrit, and MCH value was significantly lower in subjects with CD4 ≤350 mm3 (p=0.014; p=0.001; p=0.01; respectively). Lower Hb, Ht, and MCH associated with thelower CD4 count.

  14. Blood eosinophil counts for the prediction of the severity of exercise-induced bronchospasm in asthma.

    Science.gov (United States)

    Koh, Y I; Choi, S

    2002-02-01

    It has been suggested that airway eosinophilic inflammation is associated with the severity of exercise-induced bronchospasm (EIB). Blood eosinophils are known to be an indirect marker of airway inflammation in asthma. The aim of this study is to investigate that a simple and easy blood test for blood eosinphil counts may predict the severity of EIB in asthma. Seventy-seven men with perennial asthma (age range 18-23 years) were included. Lung function test, skin prick test, and blood tests for eosinophils counts and total IgE levels were performed. Methacholine bronchial provocation test and, 24 h later, free running test were carried out. EIB was defined as a 15% reduction or more in post-exercise FEV1 compared with pre-exercise FEV1 value. Atopy score was defined as a sum of mean wheal diameters to allergens. EIB was observed in 60 (78%) of 77 subjects. Asthmatics with EIB showed significantly increased percentages of eosinophils (P 700 microl(-1) (36.9 +/- 12.7%) had significantly greater maximal % fall in FEV1 after exercise than asthmatics with eosinophils of 350 microl(-1) yielded the specificity of 88% and positive predictive value of 93% for the presence of EIB. When a multiple regression analysis of maximal % fall in FEV1 according to log eosinophil counts, log PC20, log IgE and atopy score was performed, only blood eosinophil counts were significant factor contributing to the maximal % fall in FEV1 after exercise. These findings not only suggest that a simple blood test for eosinophils may be useful in the prediction of the severity of EIB, but also reinforce the view that airway eosinophilic inflammation may play a major role in EIB in asthma.

  15. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Science.gov (United States)

    Al-Marzoki, Jasim M; Al-Maaroof, Zainab W; Kadhum, Ali H

    2012-01-01

    Background The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. Methods A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. Results Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. Conclusion Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from

  16. Signatures of reproductive events on blood counts and biomarkers of inflammation: Implications for chronic disease risk.

    Directory of Open Access Journals (Sweden)

    Daniel W Cramer

    Full Text Available Whether inflammation mediates how reproductive events affect chronic-disease risk is unclear. We studied inflammatory biomarkers in the context of reproductive events using National Health and Nutrition Examination Survey (NHANES data. From 15,986 eligible women from the 1999-2011 data cycles, we accessed information on reproductive events, blood counts, C-reactive protein (CRP, and total homocysteine (tHCY. We calculated blood-count ratios including: platelet-lymphocyte (PLR, lymphocyte-monocyte (LMR, platelet-monocyte (PMR, and neutrophil-monocyte (NMR. Using sampling weights per NHANES guidelines, means for counts, ratios, or biomarkers by reproductive events were compared using linear regression. We performed trend tests and calculated p-values with partial sum of squares F-tests. Higher PLR and lower LMR were associated with nulliparity. In postmenopausal women, lower PMR was associated with early age at first birth and higher NMR with later age at and shorter interval since last birth. Lower PNR and higher neutrophils and tHCY were associated with early natural menopause. In all women, the neutrophil count correlated positively with CRP; but, in premenopausal women, correlated inversely with tHCY. Reproductive events leave residual signatures on blood counts and inflammatory biomarkers that could underlie their links to chronic disease risk.

  17. Is automated platelet counting still a problem in thrombocytopenic blood?

    Directory of Open Access Journals (Sweden)

    Raimundo Antônio Gomes Oliveira

    Full Text Available CONTEXT: Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE: To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hematology (ICSH. TYPE OF STUDY: Automated platelet counting assessment in thrombocytopenic patients. SETTING: Hematology Laboratory, Hospital do Servidor Público Estadual de São Paulo, and the Hematology Division of Instituto Adolfo Lutz, São Paulo, SP, Brazil. MAIN MEASUREMENTS: Brecher & Cronkite reference method and four different automated platelet counters. PARTICIPANTS: 43 thrombocytopenic patients with platelet counts of less than 30,000/µl RESULTS: The ADVIA-120 (Bayer, Coulter STKS, H1 System (Technicom-Bayer and Coulter T-890 automatic instruments presented great precision and accuracy in relation to laboratory thrombocytopenic samples obtained by diluting blood from normal donors. However, when thrombocytopenic patients were investigated, all the counters except ADVIA (which is based on volume and refraction index showed low accuracy when compared to the Brecher & Cronkite reference method (ICSH. The ADVIA counter showed high correlation (r = 0.947. However, all counters showed flags in thrombocytopenic samples. CONCLUSION: The Brecher & Cronkite reference method should always be indicated in thrombocytopenic patients for platelet counts below 30,000 plt /µl obtained in one dimensional counters.

  18. Peripheral blood leukocyte count as an index of defense status in the leukopenic host

    International Nuclear Information System (INIS)

    Cawley, S.; Findon, G.; Miller, T.E.

    1988-01-01

    These experimental studies have investigated the reliability of the peripheral blood leukocyte count to predict whether the leukopenic host can contain or eliminate infection. Additionally, we have investigated the possibility that determination of leukocyte recruitment, supplementary to peripheral blood leukocyte counts, might allow individuals with neutropenia at risk from serious infection to be distinguished with greater certainty. Varying doses of radiation, cyclophosphamide, and methylprednisolone were used to induce distinct levels of leukopenia in rats. Leukocyte recruitment was measured by quantifying the response of neutropenic animals to evocative, subcutaneous stimuli, and the results of this assay were then compared with circulating leukocyte counts in the same individuals. Six models of experimentally induced infection were used to compare circulating and recruitable leukocytes as indicators of the susceptibility of the leukopenic host to infection. Response curves relating leukocyte numbers to host resistance were similar when circulating or recruitable leukocytes were used as an index of defense capability. These findings support the use of peripheral blood leukocyte numbers as an index of resistance to infection in individuals with leukopenia and suggest that functional analyses such as leukocyte recruitment are unlikely to provide additional information

  19. Effect of scaling and root planing on blood counts in patients with chronic generalized periodontitis

    Directory of Open Access Journals (Sweden)

    Devinder Singh Kalsi

    2017-01-01

    Full Text Available Background: Many systemic diseases have been implicated as risk factors in periodontal disease. Studies suggest that periodontal infection can adversely affect systemic health; by inference periodontal disease will also have an effect on blood values, but the data available is not conclusive. Aim: This clinical study was designed to evaluate the effect of treatment of plaque induced periodontitis on commonly assessed blood parameters. Materials and Method: 37 males and 31 females aged between 20 and 50 years in good general health but suffering from plaque induced chronic periodontitis were selected for the study. The selected patients were assessed for ESR, TLC, PMN count, lymphocyte count from DLC, HB, BT and their periodontal condition before the start of the study. SCRP was carried out and patients were reassessed for the same clinical and hematological parameters 21 days after the periodontal therapy (SCRP. Results: A highly significant reduction in the counts of PMNs and the values of ESI was seen after SCRP. Furthermore a significant reduction in TLC, lymphocytes count, and BT and a non significant decrease in Hb were also observed. Conclusion: SCRP done in patients of chronic periodontitis has a considerable affect on the assessed blood parameters.

  20. Study on the peripheral white blood cell count in patients with type 2 diabetes complicated with microangiopathy

    International Nuclear Information System (INIS)

    Cai Wenpin; Zhu Pinghui

    2010-01-01

    Objective: To study the possible role played by peripheral white blood cells in the development of type 2 diabetes (DM2) and complication of microvascular pathological changes. Methods: White blood cell count and metabolism related parameters (FBG, 2hPBG, 2h Pinsulin, TCH, HDL, LDL, TG, HbA1c, BMI, age) were examined in 33 DM2 patients without complication, 41 DM2 patients with micro-angiopathy and 31 controls. Results: The white blood cell counts in both DM2 patients with no complication and the DM2 with microvascular pathological changes were significantly higher than those in controls (P 0.05). The white blood cell counts were positively correlated with age,body metabolism index (BMI), triglyceride (TG), 2h glucose (PBG) and 2h insulin (the r value 0.248, 0.201, 0.435, 0.225, 0.352 respectively, P<0.05). Conclusion: Peripheral white blood cells possibly played some role in development of DM2 and microvascular pathological changes and might be of some predictive importance. (authors)

  1. CORD BLOOD NUCLEATED RED BLOOD CELL COUNT: A SIMPLE BEDSIDE TEST OF PERINATAL ASPHYXIA AND ITS CORRELATION WITH IMMEDIATE OUTCOME

    Directory of Open Access Journals (Sweden)

    Ramesh Chand

    2016-07-01

    Full Text Available BACKGROUND Asphyxia is a leading cause of foetal neonatal mortality and morbidity. Nucleated red blood cell count (NRBC produced as compensatory response to asphyxia in foetus and NRBC level can be correlated to asphyxia. Because the present indices are unhelpful in the diagnosis and prediction of the severity of asphyxia, we wished to investigate the relationship between the nucleated RBC count and the severity & immediate outcome of perinatal asphyxia. METHOD This prospective comparative study was conducted in maternity ward of Obstetrics & Gynaecology Department and Paediatric Department of GSVM Medical College, Kanpur (Central UP, from January 2014 to September 2014. Newborns of term gestation were selected after satisfying inclusion criteria and were divided in 2 groups. The control group consisted 60 normal newborns and case group had 60 asphyxiated newborns. The cord blood was collected soon after birth, investigated for pH and making smears that were stained with Leishman’s stain. NRBCs were counted against 100 WBCs. The statistical analysis was done using IMSTAT. RESULTS The mean NRBC count in the study group was 22.63±6.95 as compared to 4.75±2.04 in the control group (p=<0.0001. The NRBC count was significantly higher in low pH, neonates with low Apgar scores of < 3 at 1 minutes, newborns with HIE stage III & in neonates who were neurological abnormal at discharge (P=0.0001. CONCLUSIONS A simple, easy to do, cost effective bedside test, such as NRBC count at time of delivery is a good marker of perinatal asphyxia & its forthcoming immediate neurological outcome.

  2. Evaluation of lactate, white blood cell count, neutrophil count, procalcitonin and immature granulocyte count as biomarkers for sepsis in emergency department patients.

    Science.gov (United States)

    Karon, Brad S; Tolan, Nicole V; Wockenfus, Amy M; Block, Darci R; Baumann, Nikola A; Bryant, Sandra C; Clements, Casey M

    2017-11-01

    Lactate, white blood cell (WBC) and neutrophil count, procalcitonin and immature granulocyte (IG) count were compared for the prediction of sepsis, and severe sepsis or septic shock, in patients presenting to the emergency department (ED). We prospectively enrolled 501 ED patients with a sepsis panel ordered for suspicion of sepsis. WBC, neutrophil, and IG counts were measured on a Sysmex XT-2000i analyzer. Lactate was measured by i-STAT, and procalcitonin by Brahms Kryptor. We classified patients as having sepsis using a simplification of the 1992 consensus conference sepsis definitions. Patients with sepsis were further classified as having severe sepsis or septic shock using established criteria. Univariate receiver operating characteristic (ROC) analysis was performed to determine odds ratio (OR), area under the ROC curve (AUC), and sensitivity/specificity at optimal cut-off for prediction of sepsis (vs. no sepsis), and prediction of severe sepsis or septic shock (vs. no sepsis). There were 267 patients without sepsis; and 234 with sepsis, including 35 patients with severe sepsis or septic shock. Lactate had the highest OR (1.44, 95th% CI 1.20-1.73) for the prediction of sepsis; while WBC, neutrophil count and percent (neutrophil/WBC) had OR>1.00 (psepsis or septic shock, with an odds ratio (95th% CI) of 2.70 (2.02-3.61) and AUC 0.89 (0.82-0.96). Traditional biomarkers (lactate, WBC, neutrophil count, procalcitonin, IG) have limited utility in the prediction of sepsis. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  4. Neutropenia Prediction Based on First-Cycle Blood Counts Using a FOS-3NN Classifier

    Directory of Open Access Journals (Sweden)

    Elize A. Shirdel

    2011-01-01

    Full Text Available Background. Delivery of full doses of adjuvant chemotherapy on schedule is key to optimal breast cancer outcomes. Neutropenia is a serious complication of chemotherapy and a common barrier to this goal, leading to dose reductions or delays in treatment. While past research has observed correlations between complete blood count data and neutropenic events, a reliable method of classifying breast cancer patients into low- and high-risk groups remains elusive. Patients and Methods. Thirty-five patients receiving adjuvant chemotherapy for early-stage breast cancer under the care of a single oncologist are examined in this study. FOS-3NN stratifies patient risk based on complete blood count data after the first cycle of treatment. All classifications are independent of breast cancer subtype and clinical markers, with risk level determined by the kinetics of patient blood count response to the first cycle of treatment. Results. In an independent test set of patients unseen by FOS-3NN, 19 out of 21 patients were correctly classified (Fisher’s exact test probability P<0.00023 [2 tailed], Matthews’ correlation coefficient +0.83. Conclusions. We have developed a model that accurately predicts neutropenic events in a population treated with adjuvant chemotherapy in the first cycle of a 6-cycle treatment.

  5. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  6. Peripheral blood CD34+ cell count as a predictor of adequacy of hematopoietic stem cell collection for autologous transplantation

    Directory of Open Access Journals (Sweden)

    Combariza, Juan F.

    2016-10-01

    Full Text Available Introduction: In order to carry out an autologous transplantation, hematopoietic stem cells should be mobilized to peripheral blood and later collected by apheresis. The CD34+ cell count is a tool to establish the optimal time to begin the apheresis procedure. Objective: To evaluate the association between peripheral blood CD34+ cell count and the successful collection of hematopoietic stem cells. Materials and methods: A predictive test evaluation study was carried out to establish the usefulness of peripheral blood CD34+ cell count as a predictor of successful stem cell collection in patients that will receive an autologous transplantation. Results: 77 patients were included (median age: 49 years; range: 5-66. The predominant baseline diagnosis was lymphoma (53.2 %. The percentage of patients with successful harvest of hematopoietic stem cells was proportional to the number of CD34+cells in peripheral blood at the end of the mobilization procedure. We propose that more than 15 CD34+cells/μL must be present in order to achieve an adequate collection of hematopoietic stem cells. Conclusion: Peripheral blood CD34+ cell count is a useful tool to predict the successful collection of hematopoietic stem cells.

  7. Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammed Sirdah

    2013-01-01

    Full Text Available BACKGROUND: The complete blood count is one of the most common routine tests. This study aimed to evaluate possible effects of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC over seven days. METHODS: Venous blood samples of 25 healthy males were distributed into two sets of tubes with each set of four tubes containing 50 µL of solutions with zero, 2.5 g/L, 5 g/L, 10 g/L taurine. The tubes were kept at room temperature or at 4ºC. Complete blood counts were performed on seven successive days. The mean percentage changes [Δ = (mean value - mean baseline value / mean baseline value x 100] were calculated and compared. RESULTS: Complete blood count parameters exhibited different patterns of behavior which were affected by the storage temperature, time and taurine concentration. Taurine at room temperature significantly enhancedthe stability of: the platelet count over seven days (Δ7 at 2.5, 5 and 10 g/L taurine were 5.45, 6.11, and 5.80 x 10(9 cells/L, respectively; the red blood cell count over five days (Δ5 at 2.5, 5 and 10 g/L taurine were 1.59, 2.79, and 1.98 x 10(12 cells/L, respectively; mean corpuscular hemoglobin over five days (Δ5 at 2.5, 5 and 10 g/L taurine were -0.91,-1.52 and -0.84 fl respectively; and red cell distribution width over two days (Δ2 at 2.5, 5 and 10 g/L taurine were 0.90%, 1.30% and -0.1%, respectively. No additional stabilizing effects of taurine were reported for the mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, hematocrit and hemoglobin, while it negatively affected the white blood cell stability. CONCLUSION: Complete blood count parameters exhibited variable stability patterns in respect to temperature, time and taurine concentration.

  8. Acute effects of electronic and tobacco cigarette smoking on complete blood count.

    Science.gov (United States)

    Flouris, Andreas D; Poulianiti, Konstantina P; Chorti, Maria S; Jamurtas, Athanasios Z; Kouretas, Dimitrios; Owolabi, Emmanuel O; Tzatzarakis, Manolis N; Tsatsakis, Aristidis M; Koutedakis, Yiannis

    2012-10-01

    The World Health Organisation called for research assessing the safety of electronic cigarette (e-cigarette). We evaluated the acute effect of active and passive e-cigarette and tobacco cigarette smoking on complete blood count (CBC) markers in 15 smokers and 15 never-smokers, respectively. Smokers underwent a control session, an active tobacco cigarette smoking session, and an active e-cigarette smoking session. Never-smokers underwent a control session, a passive tobacco cigarette smoking session, and a passive e-cigarette smoking session. The results demonstrated that CBC indices remained unchanged during the control session and the active and passive e-cigarette smoking sessions (P>0.05). Active and passive tobacco cigarette smoking increased white blood cell, lymphocyte, and granulocyte counts for at least one hour in smokers and never smokers (Pissues and other areas of consumer product safety of e-cigarettes, because the nicotine content in the liquids used may vary considerably. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. White blood cell counts and neutrophil to lymphocyte ratio in the diagnosis of testicular cancer: a simple secondary serum tumor marker.

    Science.gov (United States)

    Yuksel, Ozgur Haki; Verit, Ayhan; Sahin, Aytac; Urkmez, Ahmet; Uruc, Fatih

    2016-01-01

    The aim of the study was to investigate white blood cell counts and neutrophil to lymphocyte ratio (NLR) as markers of systemic inflammation in the diagnosis of localized testicular cancer as a malignancy with initially low volume. Thirty-six patients with localized testicular cancer with a mean age of 34.22±14.89 years and 36 healthy controls with a mean age of 26.67±2.89 years were enrolled in the study. White blood cell counts and NLR were calculated from complete blood cell counts. White blood cell counts and NLR were statistically significantly higher in patients with testicular cancer compared with the control group (ptesticular cancer besides the well-known accurate serum tumor markers as AFP (alpha fetoprotein), hCG (human chorionic gonadotropin) and LDH (lactate dehydrogenase).

  10. White blood cell and platelet count as adjuncts to standard clinical evaluation for risk assessment in patients at low probability of acute aortic syndrome.

    Science.gov (United States)

    Morello, Fulvio; Cavalot, Giulia; Giachino, Francesca; Tizzani, Maria; Nazerian, Peiman; Carbone, Federica; Pivetta, Emanuele; Mengozzi, Giulio; Moiraghi, Corrado; Lupia, Enrico

    2017-08-01

    Pre-test probability assessment is key in the approach to suspected acute aortic syndromes (AASs). However, most patients with AAS-compatible symptoms are classified at low probability, warranting further evaluation for decision on aortic imaging. White blood cell count, platelet count and fibrinogen explore pathophysiological pathways mobilized in AASs and are routinely assayed in the workup of AASs. However, the diagnostic performance of these variables for AASs, alone and as a bundle, is unknown. We tested the hypothesis that white blood cell count, platelet count and/or fibrinogen at presentation may be applied as additional tools to standard clinical evaluation for pre-test risk assessment in patients at low probability of AAS. This was a retrospective observational study conducted on consecutive patients managed in our Emergency Department from 2009 to 2014 for suspected AAS. White blood cell count, platelet count and fibrinogen were assayed during evaluation in the Emergency Department. The final diagnosis was obtained by computed tomography angiography. The pre-test probability of AAS was defined according to guidelines. Of 1210 patients with suspected AAS, 1006 (83.1%) were classified at low probability, and 271 (22.4%) were diagnosed with AAS. Within patients at low probability, presence of at least one alteration among white blood cell count >9*10 3 /µl, platelet count probability, white blood cell count >9*10 3 /µl and platelet count probability, the estimated risk of AAS based on the number of alterations amongst white blood cell count >9*10 3 /µl and platelet count probability to fine-tune risk assessment of AAS.

  11. Relationship of white blood cell counts, haemoglobin and ESR with IHD

    International Nuclear Information System (INIS)

    Shahzad, F.; Shahzad Tawwab, S.; Abbas, A.

    2009-01-01

    To find any association of white blood cells, haemoglobin and ESR with ischemic heart disease in high risk native population. Methodology: The study included 93 male patients with Ischemic heart disease, between 40 and 60 years of age; 96 age and gender matched subjects. All study participants were non-diabetics. Complete blood cells count, haemoglobin and ESR levels were compared between the patient and control groups. Results: Total leukocyte counts along with neutrophils were significantly higher in the test group compared to the control population (p<0.001) and lymphocytes were significantly lower (p<0.001) in the patient group as compared to the control group. Haemoglobin levels were significantly lower (p<0.001) and ESR was higher (p=0.030) in the patient group as compared to the control group. Conclusion: Although, our findings of the study variables extend previous reports, the prevalence and prognostic importance of theses variables in IHD should be assessed in future experimental studies. These parameters could be important in public health because they are routinely measured by clinicians and may be helpful to predict the risk of future and secondary ischemic events in a high risk population. (author)

  12. Application of blood cell count and retrospective biodosimetry for health protection in industrial radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seong Jae; Kim, Seung Hyun; Yang, Soo San; Cho, Min Su; Lee, Jin Kyung; Jin, Young Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2017-04-15

    Industrial radiography is known to be one of the most vulnerable lines of work among the range of different radiation work. According to the relevant law in Korea, every worker registered in this work should check their blood cell counts every year in addition to their thermoluminescent dosimeter (TLD) doses. Cytogenetic dosimetry has been employed for several decades as a method for estimating the dose of ionizing radiation (IR) received by an individual. In cases of recent acute exposure, the most reliable method is to score dicentric chromosomes in solid-stained metaphase cells. Dicentric aberrations are unstable because their frequency decrease with time after IR exposure. The purpose of the present study was to review the effectiveness of the current regulation that requires all registered radiation workers to check their blood counts every year in order to screen for exposed workers. In addition, the clinical usefulness of cytogenetic dosimetry as a retrospective tool for dose estimation has been evaluated. From this study, we hope to make practical recommendations for improving the current radiation protection regulation. We ascertain that reviewing consecutive results of blood cell counts and retrospective biodosimetry are useful complementary tools to TLD doses for health protection regulation. Several confounding factors including work duration and previous medical history need to be considered for the interpretation of cytogenetic dosimetry results.

  13. Application of blood cell count and retrospective biodosimetry for health protection in industrial radiographers

    International Nuclear Information System (INIS)

    Jang, Seong Jae; Kim, Seung Hyun; Yang, Soo San; Cho, Min Su; Lee, Jin Kyung; Jin, Young Woo

    2017-01-01

    Industrial radiography is known to be one of the most vulnerable lines of work among the range of different radiation work. According to the relevant law in Korea, every worker registered in this work should check their blood cell counts every year in addition to their thermoluminescent dosimeter (TLD) doses. Cytogenetic dosimetry has been employed for several decades as a method for estimating the dose of ionizing radiation (IR) received by an individual. In cases of recent acute exposure, the most reliable method is to score dicentric chromosomes in solid-stained metaphase cells. Dicentric aberrations are unstable because their frequency decrease with time after IR exposure. The purpose of the present study was to review the effectiveness of the current regulation that requires all registered radiation workers to check their blood counts every year in order to screen for exposed workers. In addition, the clinical usefulness of cytogenetic dosimetry as a retrospective tool for dose estimation has been evaluated. From this study, we hope to make practical recommendations for improving the current radiation protection regulation. We ascertain that reviewing consecutive results of blood cell counts and retrospective biodosimetry are useful complementary tools to TLD doses for health protection regulation. Several confounding factors including work duration and previous medical history need to be considered for the interpretation of cytogenetic dosimetry results.

  14. Association of psychological stress response of fatigue with white blood cell count in male daytime workers.

    Science.gov (United States)

    Nishitani, Naoko; Sakakibara, Hisataka

    2014-01-01

    Relationships between work-related psychological and physical stress responses and counts of white blood cells (WBCs), neutrophils, and lymphocytes were investigated in 101 daytime workers. Counts of WBCs and neutrophils were positively associated with smoking and inversely correlated with high density lipoprotein (HDL)-cholesterol levels. Additionally, general fatigue score as measured by the profile of mood state was positively correlated with WBC and neutrophil counts whereas lymphocyte counts was not significantly associated with fatigue score. Multiple regression analysis showed that WBC count was significantly related to general fatigue, age, and HDL-cholesterol levels. Neutrophil count was significantly related to HDL-cholesterol levels and fatigue score. Among various psychological stress response variables, general fatigue may be a key determinant of low-grade inflammation as represented by increases of WBC and neutrophil counts.

  15. Blood neutrophil counts in HIV-infected patients with pulmonary tuberculosis: association with sputum mycobacterial load.

    Directory of Open Access Journals (Sweden)

    Andrew D Kerkhoff

    Full Text Available Increasing evidence suggests that neutrophils play a role in the host response to Mycobacterium tuberculosis. We determined whether neutrophil counts in peripheral blood are associated with tuberculosis (TB and with mycobacterial load in sputum in HIV-infected patients.Adults enrolling in an antiretroviral treatment (ART clinic in a Cape Town township were screened for TB regardless of symptoms. Paired sputum samples were examined using liquid culture, fluorescence microscopy, and the Xpert MTB/RIF assay. Absolute neutrophil counts (ANC were measured in blood samples. Of 602 HIV-infected patients screened, 523 produced one or more sputum samples and had complete results available for analysis. Among these 523 patients, the median CD4 count was 169×10(9/L (IQR, 96-232 and median ANC was 2.6×10(9/L (IQR, 1.9-3.6. Culture-positive pulmonary tuberculosis was diagnosed in 89 patients. Patients with TB had a median ANC of 3.4×10(9/L (IQR, 2.4-5.1 compared to 2.5×10(9/L (IQR, 1.8-3.4 among those who were culture negative (p7.5×10(9/L; p = 0.0005. Patients were then classified into four mutually exclusive groups with increasing sputum mycobacterial load as defined by the results of culture, Xpert MTB/RIF and sputum smear microscopy. Multivariable analyses demonstrated that increasing sputum mycobacterial load was positively associated with blood ANC ≥2.6×10(9/L and with neutrophilia.Increased blood neutrophil counts were independently associated with pulmonary TB and sputum mycobacterial burden in this HIV-infected patient group. This observation supports the growing body of literature regarding the potential role for neutrophils in the host response to TB.

  16. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    Science.gov (United States)

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  17. Absolute counting of neutrophils in whole blood using flow cytometry.

    Science.gov (United States)

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  18. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  19. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    Science.gov (United States)

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  20. Prevalence and clinical significance of neutropenia discovered in routine complete blood cell counts: a longitudinal study

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Tesfa, D.; Siersma, Volkert Dirk

    2016-01-01

    BACKGROUND: Neutropenia, defined as an absolute blood neutrophil count (ANC) neutropenia detected in a routine complete blood cell count is poorly understood. METHODS: Using a primary care resource, comprising...... more than 370 000 individuals, we assessed the association with a number of previously recognized conditions as well as all-cause mortality in the 4 years following the identification of neutropenia. By matching laboratory data with Danish nationwide health registers, risk estimates were assessed....... RESULTS: Neutropenia was observed in approximately 1% of all individuals and was associated dose dependently with viral infections, haematological malignancies (but not autoimmune disorders or solid cancers) and mortality. Neutropenia was particularly associated with HIV, acute leukaemias...

  1. Effect of a 21-day balneotherapy program on blood cell counts, ponogen levels, and blood biochemical indexes in servicemen in sub-health condition.

    Science.gov (United States)

    Xu, Li; Wu, Lin; Liu, Tingting; Xing, Wenrong; Cao, Xinsheng; Zhang, Shu; Su, Zongyi

    2017-09-01

    [Purpose] The aim of our study was to explore the changes in the blood of servicemen in sub-health conditions during a 21-day balneotherapy program. [Subjects and Methods] For this study, 129 servicemen in sub-health condition were recruited. The subjects were randomly divided into either the balneotherapy group (70) or the control group (59). Subjects in the balneotherapy group received whole-body immersion bath therapy in thermomineral water (30 min daily) for 21 days. Their blood samples were examined 1 day before and after balneotherapy. The parameters studied included mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), lactic acid (LAC), alanine aminotransferase (ALT), glucose (GLU), and triglycerides (TG) levels. [Results] After 21 days of balneotherapy, MCH levels and MCHC increased significantly and WBC counts increased significantly. LAC levels decreased significantly. ALT, GLU, and TG levels decreased significantly. In the control group, there were no statistical differences before and after tap water baths following the same procedure. [Conclusion] A 21-day balneotherapy program significantly improved blood cell counts and blood biochemical indexes and reduced ponogen levels in servicemen in sub-health condition.

  2. Blood eosinophil count and exacerbations in severe chronic obstructive pulmonary disease after withdrawal of inhaled corticosteroids

    DEFF Research Database (Denmark)

    Watz, Henrik; Tetzlaff, Kay; Wouters, Emiel F M

    2016-01-01

    were seen with eosinophil cutoffs of 300 cells per μL and 400 cells per μL, and mutually exclusive subgroups. INTERPRETATION: Blood eosinophil counts at screening were related to the exacerbation rate after complete ICS withdrawal in patients with severe to very severe COPD and a history...... of exacerbations. Our data suggest that counts of 4% or greater or 300 cells per μL or more might identify a deleterious effect of ICS withdrawal, an effect not seen in most patients with eosinophil counts below these thresholds. FUNDING: Boehringer Ingelheim....

  3. Fibrinogen, viscosity, and white blood cell count are major risk factors for ischemic heart disease. The Caerphilly and Speedwell collaborative heart disease studies.

    Science.gov (United States)

    Yarnell, J W; Baker, I A; Sweetnam, P M; Bainton, D; O'Brien, J R; Whitehead, P J; Elwood, P C

    1991-03-01

    Recent studies have suggested that hemostatic factors and white blood cell count are predictive of ischemic heart disease (IHD). The relations of fibrinogen, viscosity, and white blood cell count to the incidence of IHD in the Caerphilly and Speedwell prospective studies are described. The two studies have a common core protocol and are based on a combined cohort of 4,860 middle-aged men from the general population. The first follow-up was at a nearly constant interval of 5.1 years in Caerphilly and 3.2 years in Speedwell; 251 major IHD events had occurred. Age-adjusted relative odds of IHD for men in the top 20% of the distribution compared with the bottom 20% were 4.1 (95% confidence interval, 2.6-6.5) for fibrinogen, 4.5 (95% confidence interval, 2.8-7.4) for viscosity, and 3.2 (95% confidence interval, 2.0-4.9) for white blood cell count. Associations with IHD were similar in men who had never smoked, exsmokers, and current smokers, and the results suggest that at least part of the effect of smoking on IHD is mediated through fibrinogen, viscosity, and white blood cell count. Multivariate analysis shows that white blood cell count is an independent risk factor for IHD as is either fibrinogen or viscosity, or possibly both. Jointly, these three variables significantly improve the fit of a logistic regression model containing all the main conventional risk factors. Further, a model including age, smoking habits, fibrinogen, viscosity, and white blood cell count predicts IHD as well as one in which the three hemostatic/rheological variables are replaced by total cholesterol, diastolic pressure, and body mass index. Jointly, fibrinogen, viscosity, and white blood cell count are important risk factors for IHD.

  4. The Preoperative Peripheral Blood Monocyte Count Is Associated with Liver Metastasis and Overall Survival in Colorectal Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Shidong Hu

    Full Text Available Colorectal cancer (CRC is the third most common malignancy in males and the second most common in females worldwide. Distant metastases have a strong negative impact on the prognosis of CRC patients. The most common site of CRC metastases is the liver. Both disease progression and metastasis have been related to the patient's peripheral blood monocyte count. We therefore performed a case-control study to assess the relationship between the preoperative peripheral blood monocyte count and colorectal liver metastases (CRLM.Clinical data from 117 patients with colon cancer and 93 with rectal cancer who were admitted to the Chinese People's Liberation Army General Hospital (Beijing, China between December 2003 and May 2015 were analysed retrospectively, with the permission of both the patients and the hospital.Preoperative peripheral blood monocyte counts, the T and N classifications of the primary tumour and its primary site differed significantly between the two groups (P 0.505 × 109 cells/L, high T classification and liver metastasis were independent risk factors for 5-year OS (RR: 2.737, 95% CI: 1.573~ 4.764, P <0.001; RR: 2.687, 95%CI: 1.498~4.820, P = 0.001; RR: 4.928, 95%CI: 2.871~8.457, P < 0.001.The demonstrated association between preoperative peripheral blood monocyte count and liver metastasis in patients with CRC recommends the former as a useful predictor of postoperative prognosis in CRC patients.

  5. The Preoperative Peripheral Blood Monocyte Count Is Associated with Liver Metastasis and Overall Survival in Colorectal Cancer Patients.

    Science.gov (United States)

    Hu, Shidong; Zou, Zhenyu; Li, Hao; Zou, Guijun; Li, Zhao; Xu, Jian; Wang, Lingde; Du, Xiaohui

    2016-01-01

    Colorectal cancer (CRC) is the third most common malignancy in males and the second most common in females worldwide. Distant metastases have a strong negative impact on the prognosis of CRC patients. The most common site of CRC metastases is the liver. Both disease progression and metastasis have been related to the patient's peripheral blood monocyte count. We therefore performed a case-control study to assess the relationship between the preoperative peripheral blood monocyte count and colorectal liver metastases (CRLM). Clinical data from 117 patients with colon cancer and 93 with rectal cancer who were admitted to the Chinese People's Liberation Army General Hospital (Beijing, China) between December 2003 and May 2015 were analysed retrospectively, with the permission of both the patients and the hospital. Preoperative peripheral blood monocyte counts, the T and N classifications of the primary tumour and its primary site differed significantly between the two groups (P colon cancer (OR: 0.078, 95%CI: 0.020~0.309, P 0.505 × 109 cells/L, high T classification and liver metastasis were independent risk factors for 5-year OS (RR: 2.737, 95% CI: 1.573~ 4.764, P <0.001; RR: 2.687, 95%CI: 1.498~4.820, P = 0.001; RR: 4.928, 95%CI: 2.871~8.457, P < 0.001). The demonstrated association between preoperative peripheral blood monocyte count and liver metastasis in patients with CRC recommends the former as a useful predictor of postoperative prognosis in CRC patients.

  6. Peripheral blood eosinophil counts and risk of colorectal cancer mortality in a large general population-based cohort study

    NARCIS (Netherlands)

    Taghizadeh, N.; Vonk, J.M.; Boezen, H.M.

    2011-01-01

    1583 Background: Few epidemiological studies have investigated the association between blood eosinophil counts and colorectal cancer incidence. The current prospective cohort study aims to investigate the association between peripheral blood eosinophils and colorectal cancer mortality risk. METHODS:

  7. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Directory of Open Access Journals (Sweden)

    Jin Woo Choi

    Full Text Available The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN. A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of

  8. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong; Kim, Hee Chan

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  9. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  10. Sex differences in step count-blood pressure association: a preliminary study in type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Priya Manjoo

    Full Text Available BACKGROUND: Walking and cardiovascular mortality are inversely associated in type 2 diabetes, but few studies have objectively measured associations of walking with individual cardiovascular risk factors. Such information would be useful for "dosing" daily steps in clinical practice. This study aimed to quantify decrements in blood pressure and glycated hemoglobin (A1C per 1,000 daily step increments. METHODOLOGY/PRINCIPAL FINDINGS: Two hundred and one subjects with type 2 diabetes underwent assessments of step counts (pedometer-measured, blood pressure, A1C and anthropometric parameters. Due to missing data, the final analysis was conducted on 83 women and 102 men, with a mean age of 60 years. Associations of daily steps with blood pressure and A1C were evaluated using sex-specific multivariate linear regression models (adjusted for age, ethnicity, and BMI. Potential sex differences were confirmed in a combined model (women and men with interaction terms. Mean values for daily steps, blood pressure, A1C and BMI were 5,357 steps/day; 137/80 mm Hg; 7.7% and 30.4 kg/m(2 respectively. A 1,000 daily step increment among women was associated with a -2.6 (95% CI: -4.1 to -1.1 mm Hg change in systolic and a -1.4 (95% CI: -2.2 to -0.6 mm Hg change in diastolic blood pressure. Among men, corresponding changes were -0.7 (95% CI: -2.1 to 0.7 and -0.6 (95% CI: -1.4 to 0.3 mm Hg, respectively. Sex differences were confirmed in combined models. Step counts and A1C did not demonstrate clinically important associations. CONCLUSIONS/SIGNIFICANCE: A 1,000 steps/day increment is associated with important blood pressure decrements among women with type 2 diabetes but the data were inconclusive among men. Targeted "dose increments" of 1,000 steps/day in women may lead to measurable blood pressure reductions. This information may be of potential use in the titration or "dosing" of daily steps. No associations were found between step count increments and A1C.

  11. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  12. Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects

    Directory of Open Access Journals (Sweden)

    Hambleton K

    2017-09-01

    Full Text Available Kirsty Hambleton, Clare M Connolly, Catherine Borg, Joanne H Davies, Helen P Jeffers, Richard EK Russell, Mona Bafadhel Respiratory Medicine Unit, Nuffield Department of Clinical Medicine, University of Oxford, Oxford, UK Abstract: Near-patient testing (NPT allows clinical decisions to be made in a rapid and convenient manner and is often cost effective. In COPD the peripheral blood eosinophil count has been demonstrated to have utility in providing prognostic information and predicting response to treatment during an acute exacerbation. For this potential to be achieved having a reliable NPT of blood eosinophil count would be extremely useful. Therefore, we investigated the use of the HemoCue® WBC Diff System and evaluated its sensitivity and specificity in healthy, asthmatic and COPD subjects. This method requires a simple skin prick of blood and was compared to standard venepuncture laboratory analysis. The HemoCue® WBC Diff System measured the peripheral blood eosinophil count in healthy, asthma and COPD subjects with very close correlation to the eosinophil count as measured by standard venepuncture. The correlations were unaffected by disease status. This method for the measurement of the peripheral blood eosinophil count has the potential to provide rapid near-patient results and thus influence the speed of management decisions in the treatment of airway diseases. Keywords: asthma, chronic obstructive pulmonary disease, eosinophils, near-patient testing

  13. A comparative study on the blood and milk cell counts of healthy, subclinical and clinical mastitis Karan Fries cows

    Directory of Open Access Journals (Sweden)

    Mohanned Alhussien

    2015-05-01

    Full Text Available Aim: The present study was aimed to study the use of cell counts as an early indicator of mammary health. Materials and Methods: Milk and blood cell counts were estimated from 8 healthy, 8 subclinical (SCM, and 8 clinically mastitis (CM groups of Karan Fries (KF cows. Results: Total leucocyte counts and neutrophil percent in blood and milk somatic cells and milk neutrophil percent of healthy cows increased significantly (p<0.05 in SCM cows and CM cows. Viability of blood and milk neutrophils was more in healthy cows, but decreased significantly (p<0.05 in SCM and CM cows. Significant (p<0.05 decrease were also observed in both the blood and milk lymphocytes and monocytes of SCM and CM cows. Phagocytic activity (PA of blood neutrophils also decreased significantly (p<0.05 in SCM cows. There was no difference between the PA of SCM and CM cows. Milk neutrophil percent was more in the SCM and clinically infected milk than in the blood of these cows. About 96-97% of the neutrophils had segmented nucleus in both healthy and subclinical milk, whereas, 2-3% were having band shaped or immature nuclei. There was a significant decrease in the segmented neutrophils, whereas, band neutrophils increase significantly to about 5% in the infected milk of mastitic cows. Viability of the milk neutrophils decreased more in case of subclinical and clinical milk as compared to that of blood. PA was found to be highest in the milk of healthy group of cows, but decreased significantly (p<0.05 in subclinically infected cows. However, there was no difference between the PA of milk neutrophils of SCM and CM cows. PA of milk was also found to be significantly lower in the milk of healthy cows when compared to that of blood neutrophils. Conclusion: This study indicated that percent neutrophils and their type in conjunction with milk somatic cell counts can be used as a more reliable indicator of mammary health in cows.

  14. [Changes and significance of peripheral blood platelet count in tumor shrinkage induced by a low dose of CTX in T739 mice].

    Science.gov (United States)

    Li, Mo-lin; Jia, Yu-jie; Jiang, Miao-na; Shu, Xiao-hong; Li, Chuan-gang

    2008-06-01

    To establish a mouse model for BTT739 tumor-bearing mice cured by a low dose of cyclophosphamide (CTX). And then to observe the dynamic changes and significance of peripheral blood counts especially blood platelet count during tumor shrinkage induced by a low dose of CTX in T739 mice. Mouse bladder carcinoma tissues were inoculated subcutaneously into T739 mice. Seven days later, different doses of CTX or the same volume of NS were administered intraperitoneally to treat these tumor-bearing T739 mice. Tumor sizes were observed and recorded subsequently to find out the minimal dose of CTX that could cure most of these tumor-bearing mice. Then another 12 tumor-bearing mice were randomly divided into 15 mg/kg CTX treatment group and control group. Blood samples were obtained from orbital venous sinus on different times after CTX treatment. Complete blood counts were performed and the relationship between peripheral blood platelet counts and tumor shrinkage was analyzed. Within 2 weeks after CTX treatment, the speed of tumor shrinkage had a positive relationship with the dose of CTX used; but the survival rate of the tumor-bearing mice had a negative relationship with the dose of CTX used in 2 months after CTX treatment. 15 mg/kg CTX could cure most of the tumor bearing mice, while it had no remarkably inhibitive effects on peripheral blood cells. The perpherial platelet count increased to (1483.4+/-184.4)x10(9)/L in mice 6 h after CTX treatment. There was significant difference compared with that in mice of control group (1086.6+/-81.0)x10(9)/L (P0.05). CTX 15 mg/kg could cure most of bladder tumor-bearing T739 mice. The transient increase of the peripheral platelet count in 6 h after CTX treatment may relate to the antitumor effects of CTX.

  15. Effect of number of cigarettes smoked per day on red blood cell, lecocyte and platelet count in adult Indian male smokers – A case control study

    Directory of Open Access Journals (Sweden)

    Bharati Anil Sherke

    2016-02-01

    Full Text Available The effects of cigarette smoking are fatal. Present study was done to compare cell counts of blood in males smoking different number of cigarettes per day and non smokers of Hyderabad city. 150 consenting subjects of which 30 controls (non-smokers and 120 cases (smokers were studied. Smokers were divided into four groups based on number of cigarettes smoked per day. Blood samples processed using Hematology analyser (ABX Micros60®, HORIBA, Kyoto, Japan. The smokers had significantly different red blood cell counts (p<0.0001, white blood cells counts (p<0.0001 including neutrophils, lymphocytes, monocytes and eosinophils. This effect was significant irrespective of the number of cigarettes. There was no significant change in the percentage of basophils and platelet counts. Conclusion: Our findings showed that cigarette smoking has a significant effect on hematological cell counts and these counts changed significantly with increasing number of cigarettes smoked per day.

  16. The hematology of captive Bobtail lizards (Tiliqua rugosa): blood counts, light microscopy, cytochemistry, and ultrastructure.

    Science.gov (United States)

    Moller, Cheryl A; Gaál, Tibor; Mills, Jennifer N

    2016-12-01

    Bobtail lizards (Tiliqua rugosa) are native to Australia. The only previous study on the hematology of this species documented just 6 animals. The aims of this study were to characterize the light microscopy, ultrastructure and cytochemistry of blood cells, and evaluate CBCs of captive Bobtail lizards. Over 2 consecutive summers, heparinized venous blood was collected from the ventral coccygeal vein of 46 clinically healthy, captive indoor- or outdoor-housed adult Bobtails. Complete blood cell counts and smear evaluations were performed, and cytochemical stains and transmission electron microscopy were used to further characterize blood cells. The eosinophils of this species were uniformly vacuolated: a unique feature not previously reported in reptiles. Heterophils were the predominant leukocyte, with fewer lymphocytes, azurophilic and nonazurophilic monocytes, occasional eosinophils, and basophils. Thrombocytes were frequently clumped. Slight polychromasia (0-15% of erythrocytes) was typically present. Hemogregarine parasites were seen on some smears. The range of CBC results was often wide. The PCV ranged from 11% to 38%. Total plasma proteins by refractometry were between 3.5 and 7.8 g/dL. Hemoglobin ranged between 2.6 and 12.6 g/dL by the modified hemoglobin-hydroxylamine method. Manual RBC count was 0.35-1.27 × 10 6 /μL, and WBC count was 2.86-22.66 × 10 3 /μL. Bobtail lizards housed outdoors had lower PCVs than indoor-housed animals. Bobtails with hemogregarine infections had lower PCVs than noninfected lizards. Ranges for CBC data were often very wide, influenced by preanalytic and analytic factors. Hemogregarine infection is associated with a decreased PCV, suggesting that some hemogregarine species are pathogenic in this population. © 2016 American Society for Veterinary Clinical Pathology.

  17. White Blood Cell Count and Total and Cause-Specific Mortality in the Women's Health Initiative.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi Y; Manson, JoAnn E; Lessin, Lawrence; Lin, Juan; Wassertheil-Smoller, Sylvia; Rohan, Thomas E

    2017-07-01

    White blood cell (WBC) count appears to predict total mortality and coronary heart disease (CHD) mortality, but it is unclear to what extent the association reflects confounding by smoking, underlying illness, or comorbid conditions. We used data from the Women's Health Initiative to examine the associations of WBC count with total mortality, CHD mortality, and cancer mortality. WBC count was measured at baseline in 160,117 postmenopausal women and again in year 3 in 74,375 participants. Participants were followed for a mean of 16 years. Cox proportional hazards models were used to estimate the relative mortality hazards associated with deciles of baseline WBC count and of the mean of baseline + year 3 WBC count. High deciles of both baseline and mean WBC count were positively associated with total mortality and CHD mortality, whereas the association with cancer mortality was weaker. The association of WBC count with mortality was independent of smoking and did not appear to be influenced by previous disease history. The potential clinical utility of this common laboratory test in predicting mortality risk warrants further study. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats—Multiple factorial regression analysis

    International Nuclear Information System (INIS)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-01-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200–240 g for 28 days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15 mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000 mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight

  19. Radiological features of pulmonary tuberculosis in human immunodeficiency virus-infected patients: correlation with the blood CD4 cell count

    International Nuclear Information System (INIS)

    Isusi, M.; Eguidazu, J.; Oleaga, L.; Grande, D.

    2000-01-01

    To describe the radiological features of pulmonary tuberculosis (TB) in patients infected with human immunodeficiency virus (HIV) and its correlation with the blood CD4 cell count. We present 44 HIV+patients, 24 with CD4 cell counts of less than 200 cells/mm''3 (group A) and 20 in whom the CD4 counts surpassed this level (group B). We also assessed the chest x-ray images to determine whether or not there was any correlation with the blood CD4 cell counts. Fisher's exact test was used for the statistical study of the differences in the radiological findings in the two groups. The incidence of atypical features was significantly greater in the patients with CD4 cell counts of less than 200 cells/mm''3 (group A) than in those with CD4 counts of over 200 cells/mm''3 (group B). Among HIV+patients, those with a more intact immune status were more likely to present lung x-ray images typical of post-primary TB, with cavitary lesions in upper lobes. The group of patients in whom the immune deficiency was more marked showed a greater incidence of atypical pulmonary findings, more characteristics of primary TB. (Author)

  20. Sex based levels of C-reactive protein and white blood cell count in subjects with metabolic syndrome: Isfahan Healthy Heart Program.

    Science.gov (United States)

    Gharipour, Mojgan; Ramezani, Mohammad Arash; Sadeghi, Masuomeh; Khosravi, Alireza; Masjedi, Mohsen; Khosravi-Boroujeni, Hossein; Rafieian-Kopaei, Mahmoud; Sarrafzadegan, Nizal

    2013-06-01

    C-reactive protein (CRP) and white blood cell (WBC) are proinflammatory markers. They are major pathophysiological for the development of metabolic syndrome (MetS). This study aimed to address the independent associations between MetS and WBC counts and serum CRP levels and evaluation of their magnitude in relation to the MetS, based on the sex in the Iranian adults. In this cross-sectional study, subjects who met the MetS criteria, based on the Adult Treatment Panel III were selected from the Isfahan Healthy Heart Program database. A questionnaire containing the demographic data, weight, height, waist, and hip circumference of the respondents was completed for each person. Blood pressure was measured and the anthropometric measurements were done, and fasting blood samples were taken for 2 h postload plasma glucose (2 hpp). Serum [total, high-density lipoprotein (HDL), and low-density lipoprotein] levels of cholesterol, triglyceride, and CRP as well as WBC counts were determined. The univariate analyses were carried out to assess the relation between the CRP levels, WBC counts with the MetS in both sexes the. In men with the abdominal obesity, the higher levels of WBC count, high serum triglyceride and blood glucose levels, a low serum HDL level, and raised systolic and diastolic blood pressure were observed. However, the higher serum CRP levels were only observed in those with the low serum HDL-cholesterol levels. The mean values of the WBC counts were statistically different between the men with and without MetS, but the mean values of the CRP levels were similar between the two groups. In women, the mean values of WBC count and CRP levels were statistically different in the subjects with and without a MetS components (except for the low serum HDL levels and high diastolic blood pressure for the WBC measures and abdominal obesity for the CRP measures) and for those with and without MetS. The age and smoking adjusted changes in the CRP levels and WBC counts

  1. Pre-therapeutic blood dosimetry in patients with differentiated thyroid carcinoma using 124-iodine. Predicted blood doses correlate with changes in blood cell counts after radioiodine therapy and depend on modes of TSH stimulation and number of preceding radioiodine therapies

    International Nuclear Information System (INIS)

    Hartung-Knemeyer, V.; Nagarajah, J.; Jentzen, W.; Ruhlmann, M.; Freudenberg, L.S.; Stahl, A.R.; Bockisch, A.; Rosenbaum-Krumme, S.J.

    2012-01-01

    Pre-therapeutic blood dosimetry prior to a high-dose radioiodine therapy (RAIT) is recommended and a blood dose of 2 Gy is considered to be safe. In this study, changes in the blood cell count after radioiodine therapy of high risk differentiated thyroid carcinoma (DTC) were analyzed and compared with the results of the pre-therapeutic blood dosimetry using 124 I. Moreover, the influence of different modes of TSH stimulation and the number of preceding radioiodine therapies on the blood dose were assessed. 198 patients with locally advanced or metastasized DTC received a pre-therapeutic blood dosimetry using 124 I. To analyze the influence of the modes of TSH stimulation and the number of preceding RAITs on blood dose subgroups were built as follows: patients with endogenous TSH stimulation versus patients with exogenous TSH stimulation and patients with no preceding RAIT versus patients with at least one preceding RAIT. In 124/198 patients subsequent RAIT was performed. In 73/124 patients, hemograms were performed from day 2 to 12 month after RAIT. There was no high-grade bone marrow toxicity (id est (i.e.) ≥grade 3) in patients receiving less than 2 Gy blood dose-independent of the therapeutic history. Within the first month after radioiodine therapy, there was an overall decrease in the white blood cell and platelet counts. The erythrocyte count was essentially stable. There was a correlation between cell count decrease and predicted blood doses (Spearman's correlation coefficient >-0.6 each) for the white cell line and the platelets. With regard to the subgroups, the blood dose per administered 131 I activity (BDpA) was significantly higher in patients with endogenous TSH stimulation (median 0.08 Gy/GBq) than in patients with exogenous TSH stimulation (0.06 Gy/GBq) and in patients with no previous RAIT (0.08 Gy/GBq) compared to patients who had previously undergone at least one RAIT (0.07 Gy/GBq). The range of BDpA among DTC patients is rather wide. Our

  2. Effect of prewarming EDTA blood samples to 37°C on platelet count measured by Sysmex XT-2000iV in dogs, cats, and horses.

    Science.gov (United States)

    Williams, Tim L; Archer, Joy

    2016-09-01

    Pseudothrombocytopenia secondary to platelet clumping is a common cause of preanalytic error for platelet counts in dogs, cats, and horses. In human beings, it is suggested that prewarming blood samples to 37°C prior to hematology analysis will reduce platelet clumping. The purpose of the study was to evaluate the effect of prewarming EDTA blood samples to 37°C on measured platelet counts and other hematologic variables. The EDTA blood samples from dogs, cats and horses submitted to the clinical pathology laboratory at the University of Cambridge were included. Complete blood cell counts performed using a Sysmex XT-2000iV hematology analyzer were done on samples at room temperature (approximately 22°C) and following warming of the samples to 37°C in a water bath. The Wilcoxon signed rank test was used to compare hematologic variables, including platelet count, before and after sample warming to 37°C. Data are presented as median (25(th) , 75(th) percentile) increase. Blood samples from 39 dogs, 19 cats, and 10 horses were included. Sample warming to 37°C resulted in a statistically significant increase in platelet counts in dogs (11 [-2, 30] ×10(9) /L), cats (36 [14, 84] ×10(9) /L), and horses (42 [31, 79] ×10(9) /L). Sample warming did not significantly affect other hematologic variables. Prewarming EDTA blood samples to 37°C prior to hematologic analysis increased platelet counts overall in canine, feline, and equine blood, but did not abrogate platelet clumping and pseudothrombocytopenia fully in some cases. Furthermore, true pseudothrombocytopenia was not confirmed in these animals. © 2016 American Society for Veterinary Clinical Pathology.

  3. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  4. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats-Multiple factorial regression analysis.

    Science.gov (United States)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-02-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200-240g for 28days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight antagonism

  5. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  6. Absolute counts of peripheral blood leukocyte subpopulations in intraabdominal sepsis and pneumonia-derived sepsis: a pilot study Absolute counts of peripheral blood leukocyte subpopulations in intraabdominal sepsis and pneumonia-derived sepsis: a pilot study

    Directory of Open Access Journals (Sweden)

    Grazyna Anna Hoser

    2012-10-01

    Full Text Available The leading pathophysiological changes during sepsis include systemic abnormalities in the immune
    response. Due to the general character of these disturbances, sepsis is usually studied as a homogenous clinical
    condition. We aimed to compare the immune response in intraabdominal sepsis (IAS and pneumonia-derived
    sepsis (PDS. The following cell populations were examined: white blood cell count (WBC, monocytes, lymphocytes:
    CD3+, CD4+ and CD8+ T cells, B cells, and NK cells. In both studied groups (i.e. IAS and PDS, the
    WBC was elevated. However, it was significantly higher in the IAS group than in the PDS group. The difference
    was due to a lower granulocyte count, as well as a lower monocyte count in PDS. We found no significant
    correlation between the total lymphocyte number and CD3+CD8+ T cells in either form of sepsis. Similarly, we
    observed no correlation between the total lymphocyte number and the NK cells subset in IAS. However, the
    numbers of CD3+CD8+ and NK cells correlated similarly in both types of sepsis. Both studied types of sepsis
    induced profound lymphocytopenia, with marked loss of CD8+ T cells and the NK cells. However, the similar
    relation between them, which was independent of the infection type, suggests that the NK and CD3+CD8+ cells
    have shared mechanisms of regulation. The primary site of infection has an impact on the global immune reaction.
    These alternations include especially myeloid cells: granulocytes and monocytes which disappear from peripheral
    blood during PDS, but increase in IAS.
    The leading pathophysiological changes during sepsis include systemic abnormalities in the immune
    response. Due to the general character of these disturbances, sepsis is usually studied as a homogenous clinical
    condition. We aimed to compare the immune response in intraabdominal sepsis (IAS and pneumonia-derived
    sepsis (PDS. The following cell

  7. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy

    Directory of Open Access Journals (Sweden)

    Hajar-Alsadat Mansouri-Tehrani

    2015-01-01

    Full Text Available Background: Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Materials and Methods: Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1 Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles (n = 22, (2 probiotic capsules plus honey (n = 21 or (3 placebo capsules (n = 24 all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. Results: White blood cells (WBC, red blood cells (RBC, platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10 6 cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10 3 cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10 3 cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. Conclusion: The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of

  8. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy.

    Science.gov (United States)

    Mansouri-Tehrani, Hajar-Alsadat; Rabbani-Khorasgani, Mohammad; Hosseini, Sayyed Mohsen; Mokarian, Fariborz; Mahdavi, Hoda; Roayaei, Mahnaz

    2015-07-01

    Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1) Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles) (n = 22), (2) probiotic capsules plus honey (n = 21) or (3) placebo capsules (n = 24) all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. White blood cells (WBC), red blood cells (RBC), platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey) during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10(6) cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10(3) cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10(3) cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of probiotics or probiotic plus honey on hematologic and

  9. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    Science.gov (United States)

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  10. The Relationship Between the Gensini Score and Complete Blood Count Parameters in Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Muhammet Raşit Sayın

    2012-08-01

    Full Text Available Introduction: The aim of this study was to evaluate the relationship between the extend andseverity of coronary artery disease (CAD determined by the Gensini score and complete bloodcount parameters (white blood cell, hemoglobin, platelet, mean platelet volume, lymphocyte,neutrophil.Patients and Methods: Ninety patients with CAD underwent coronary angiography (40 females,mean age 61 ± 1.2 years were included in this study. Patients with acute coronary syndrome andprior cardiovascular disease excluded from the study. The association between the extent andseverity of CAD, which were assessed by the Gensini score, and complete blood count parameterswas analyzed by a correlation analysis.Results: Coronary angiography revealed, 6 (6.7% patients had three, 16 (17.8% patients hadtwo, and 24 (26.7% patients had single-vessel disease; 44 (48.9% patients had non-criticalstenosis. The mean Gensini score was 19.1 ± 2.1. We found a relationship between white bloodcell and neutrophil counts and the Gensini score. There was no relationship between Gensiniscore and the mean platelet volume and other parameters.Conclusion: The present study supports the hypothesis that inflammation is one of the maincomponent in the pathogenesis of CAD.

  11. Associations of White Blood Cell Count,Alanine Aminotransferase,and Aspartate Aminotransferase in the First Trimester withGestational Diabetes Mellitus.

    Science.gov (United States)

    Zhao, Li-li; Li, Wei; Ping, Fan; Ma, Liang-kun; Nie, Min

    2016-06-10

    Objective To explore the associations of white blood cell (WBC) count,alanine aminotransferase (ALT),and aspartate aminotransferase(AST) in the first trimester of pregnancy with gestational diabetes mellitus (GDM). Methods Totally 725 GDM women and 935 women who remained euglycemic throughout pregnancy were enrolled in this study. Pre-pregnancy weight/height were recorded. WBC,ALT,and AST levels were detected between 8 and 12 weeks of pregnancy.At 24 to 28 weeks of pregnancy,the glucose and insulin levels were measured. The WBC,ALT,and AST levels were compared between two groups,and the associations of WBC,ALT,and AST levels with the blood glucose and insulin levels were retrospectively analyzed. Meanwhile,the potential associations of those factors with the occurrence of GDM were analzyed. Results WBC count [9.41(8.15,10.84)?10(9)/L vs. 9.04 (7.64,10.37)?10(9)/L,P=1.0?10(-5)] and ALT levels [18.00(12.00,30.00)U/L vs. 16.00 (11.00,26.00)U/L,P=0.004] in the first trimester of pregnancy were significantly increased in GDM subjects than in normal glucose tolerance(NGT)subjects;however,the AST level showed no significant difference between these two groups [41.00 (26.00,43.00)U/L vs. 41.00 (23.00,43.00)U/L,P=0.588]. Logistic regression analysis illustrated that elevated WBC count was an independent risk factor for GDM after adjustment for age,pre-pregnancy body mass index,blood pressure,and family history of diabetes(OR=1.119,P=0.001). The ROC curve revealed that threshold of WBC count was 7.965?10(9)/L(AUC=0.566,P=1?10(-5)),which had a sensitivity of 79.4% and a specificity of 31.3%. Multivariate linear regression analysis showed that homeostasis model assessment of insulin resistance was positively correlated with WBC count(B=0.051,P=0.022,R(2)=0.083);1-hour blood glucose after oral 50 grams of sugar (B=0.044,P=0.001,R(2)=0.044) and fasting plasma true insulin(B=0.214,P=0.032,R(2)=0.066) were positively correlated with WBC count;1-hour true insulin after 100 grams

  12. Evaluation of correlation between nucleated red blood cell count in term newborns and meconium-stained amniotic fluid

    Directory of Open Access Journals (Sweden)

    Esmaeilian L

    2001-09-01

    Full Text Available Considering the incidence of meconium-stained amniotic fluid (MSAF in newborns and its complications, and also based on indirect reports pointing out relationship between nucleated red blood cell (nRBC, as a marker of chronic hypoxia, and MSAF in term newborns, and in order to determine this relationship more accurately, this study was done on women with uncomplicated singleton term pregnancy that admitted for delivery at Shariati hospital in year 2000. After excluding confounding factors on nRBC, case group who includes infants with MSAF, and control group who have clear amniotic fluid were determined. Maternal age and parity, gestational age, birth weight, apgar score, neonatal out come, and FHR pattern as well as newborn hemoglobin values were evaluated. Venous cord blood was analyzed for nRBC counts per 100 WBC. Case and control groups were divided according to nRBC counts with cutoff point of 10 and then compared statistically. From the samples, 117 cases and 67 controls were evaluated. Maternal and neonatal factors were similar in two situations. Number of nRBC was 3.75±4.8 in control group and 12.04±11.7 in case group (P<0.01 and it was abnormal (>10 in 9 percent of newborns with clear fluid and 32 percent of MSAF (P<0.01. Cord blood nRBC count increased when meconium is passed intrauterine. This suggests that cases with MSAF may be at risk of chronic hypoxia. Cohort research is recommended to study the affect of delivery mode on the neonatal outcome in cases with MSAF and to evaluate the cause of fetal hypoxia in uncomplicated pregnancy with MSAF.

  13. White blood cell counts, insulin resistance, vitamin D levels and sarcopenia in Korean elderly men.

    Science.gov (United States)

    Kim, Sang-Hwan; Kwon, Hyun Seok; Hwang, Hee-Jin

    2017-05-01

    Sarcopenia is a major determinant of frailty, disability and mortality in the elderly. Whether low-grade inflammation, insulin resistance and vitamin D are independently associated with sarcopenia remains unclear. In our study, sarcopenia was defined as an appendicular skeletal muscle mass divided by height squared (ASM/Ht 2 ) that was sarcopenia in Korean elderly men aged more than 65 years was 11.2%. ASM/Ht 2 were positively associated with vitamin D levels, but negatively associated with white blood cell counts and HOMA-IR by multiple regression analysis. After adjustment for covariables, sarcopenia was associated with the highest quartile of WBC counts (OR = 2.93, 95% CI = 1.21-7.14) and the highest quartile of serum vitamin D levels (OR = 0.38, 95% CI = 0.15-0.95). In conclusion, the study findings suggest that higher WBC counts and lower vitamin D levels are independently associated with the presence of sarcopenia in community-dwelling elderly men. They also provide a basis for further studies of the complex immune-endocrine network in sarcopenia.

  14. C-reactive protein and white blood cell count do not improve clinical decision-making in acute appendicitis

    DEFF Research Database (Denmark)

    Tind, Sofie; Lassen, Annmarie Touborg; Zimmermann-Nielsen, Erik

    2015-01-01

    INTRODUCTION: Acute appendicitis (AA) remains a diagnostic challenge as indicated by the high rate of unnecessary surgery. Blood samples, primarily C-reactive protein (CRP) and leucocyte counts, are used as a diagnostic supplement despite their relatively low sensitivities and specificities...... the blood results and re-evaluate their diagnosis. The surgeon's diagnosis before and after was compared with the final diagnosis defined by surgical findings or follow-up. The gold standard was any degree of appendicitis on histology. RESULTS: A total of 226 patients were included of whom 91 (40.3%) had...... appendicitis on histology. The surgeons changed their diagnosis in nine cases after assessing blood samples. The changes in the proportion of correct diagnoses, sensitivity, specificity and predictive values after assessing blood samples were not significant. CONCLUSIONS: The results of CRP and leucocyte...

  15. White blood cell count, absolute neutrophil count, as predictors of hidden bacterial infections in febrile children 1-18 months of age without focus

    International Nuclear Information System (INIS)

    AL-Majali, R.M.

    2004-01-01

    Objectives: To study the relationship between White Blood Cell (WBC), Absolute Neutrophil Count (ANC) in febrile children 1-18 months of age as predictor of bacterial infection, so as to improve our predictability of bacterial infections in emergency room to decrease unnecessary admissions and antibiotic use. Methods: Retrospective review was performed on febrile patients 1-18 months of age that were admitted to hospital between August 2002 and March 2003 on the presumptive diagnosis of fever without focus, Complete septic work up was done for all patients according to local hospital protocol including Complete blood count (CBC), blood culture, urine culture, Chest X-Ray (CXR) and lumbar puncture, Patients who had history of antibiotics use within 48 hours of admission were excluded from the study, History, physical examination, laboratory and radiology data were reviewed. Data about the age, sex, temperature, presence or absence of focal bacterial infection, WBC, ANC, CXR report and body fluid culture results were collected and analyzed. Results: Thirty-four patients were reviewed in this study, Eight patients (23.5%) had bacterial infection: classified as group (2 patchy pneumonia, 3 Urinary tract infection (UTI), 2 meningitis, 1 Occult bacteremia (OB) and 26 patients (76.5%) had no evidence of bacterial infection, classified as group 2, No significant difference was found between the two groups in respect to age, sex, temperature and WBC P>0.05, while there was a significant difference between the two groups in respect to the ANC P = 0.02, also ANC had better sensitivity (78%) and specificity (89%) than WBC (sensitivity 77%, specificity 62%). Conclusion: ANC is a good predictive test for determining bacterial infection in young febrile children without focus, However there is need for other more reliable rapid cost effective measures in dealing with young febrile children at emergency department. (author)

  16. Usefulness of estimation of blood procalcitonin concentration versus C-reactive protein concentration and white blood cell count for therapeutic monitoring of sepsis in neonates

    Directory of Open Access Journals (Sweden)

    Agnieszka Kordek

    2014-12-01

    Full Text Available Aim: This study was intended to assess the clinical usefulness of blood procalcitonin (PCT concentrations for the diagnosis and therapeutic monitoring of nosocomial neonatal sepsis.Material/Methods: The enrolment criterion was sepsis clinically manifesting after three days of life. PCT concentrations were measured in venous blood from 52 infected and 88 uninfected neonates. The results were interpreted against C-reactive protein (CRP concentrations and white blood cell counts (WBC.Results: Differences between the two groups in PCT and CRP concentrations were highly significant. No significant differences between the groups were noted for WBC. The threshold value on the receiver operator characteristic curve was 2.06 ng/mL for PCT (SE 75%; SP 80.68%; PPV 62.22%; NPV 88.75%; AUC 0.805, 5.0 mg/L for CRP (SE 67.44%; SP 73.68%; PPV 42.02%; NPV 88.89%; AUC 0.801, and 11.9 x109/L for WBC (SE 51.16%; SP 50.68%; PPV 23.16%; NPV 78.13%; AUC 0.484. Procalcitonin concentrations decreased 24 hours after initiation of antibiotic therapy and reverted to the control level after 5-7 days. C-reactive protein concentrations began to decline after two days of antibiotic therapy but were still higher than in the control group after 5-7 days of treatment. No significant changes in WBC during the treatment were observed.Conclusions: Procalcitonin concentrations in blood appear to be of use for the diagnosis and therapeutic monitoring of nosocomial infections in neonates as this parameter demonstrates greater sensitivity and specificity than C-reactive protein. White blood cell counts appear to be of little diagnostic value in the early phase of infection or for therapeutic monitoring.

  17. Maintenance therapy of childhood acute lymphoblastic leukemia revisited-Should drug doses be adjusted by white blood cell, neutrophil, or lymphocyte counts?

    Science.gov (United States)

    Schmiegelow, Kjeld; Nersting, Jacob; Nielsen, Stine Nygaard; Heyman, Mats; Wesenberg, Finn; Kristinsson, Jon; Vettenranta, Kim; Schrøeder, Henrik; Weinshilboum, Richard; Jensen, Katrine Lykke; Grell, Kathrine; Rosthoej, Susanne

    2016-12-01

    6-Mercaptopurine (6MP) and methotrexate (MTX) based maintenance therapy is a critical phase of childhood acute lymphoblastic leukemia treatment. Wide interindividual variations in drug disposition warrant frequent doses adjustments, but there is a lack of international consensus on dose adjustment guidelines. To identify relapse predictors, we collected 28,255 data sets on drug doses and blood counts (median: 47/patient) and analyzed erythrocyte (Ery) levels of cytotoxic 6MP/MTX metabolites in 9,182 blood samples (median: 14 samples/patient) from 532 children on MTX/6MP maintenance therapy targeted to a white blood cell count (WBC) of 1.5-3.5 × 10 9 /l. After a median follow-up of 13.8 years for patients in remission, stepwise Cox regression analysis did not find age, average doses of 6MP and MTX, hemoglobin, absolute lymphocyte counts, thrombocyte counts, or Ery levels of 6-thioguanine nucleotides or MTX (including its polyglutamates) to be significant relapse predictors. The parameters significantly associated with risk of relapse (N = 83) were male sex (hazard ratio [HR] 2.0 [1.3-3.1], P = 0.003), WBC at diagnosis (HR = 1.04 per 10 × 10 9 /l rise [1.00-1.09], P = 0.048), the absolute neutrophil count (ANC; HR = 1.7 per 10 9 /l rise [1.3-2.4], P = 0.0007), and Ery thiopurine methyltransferase activity (HR = 2.7 per IU/ml rise [1.1-6.7], P = 0.03). WBC was significantly related to ANC (Spearman correlation coefficient, r s  = 0.77; P best hematological target for dose adjustments of maintenance therapy. © 2016 Wiley Periodicals, Inc.

  18. Straw blood cell count, growth, inhibition and comparison to apoptotic bodies

    Directory of Open Access Journals (Sweden)

    Tomkins Jeffrey P

    2008-05-01

    Full Text Available Abstract Background Mammalian cells transform into individual tubular straw cells naturally in tissues and in response to desiccation related stress in vitro. The transformation event is characterized by a dramatic cellular deformation process which includes: condensation of certain cellular materials into a much smaller tubular structure, synthesis of a tubular wall and growth of filamentous extensions. This study continues the characterization of straw cells in blood, as well as the mechanisms of tubular transformation in response to stress; with specific emphasis placed on investigating whether tubular transformation shares the same signaling pathway as apoptosis. Results There are approximately 100 billion, unconventional, tubular straw cells in human blood at any given time. The straw blood cell count (SBC is 45 million/ml, which accounts for 6.9% of the bloods dry weight. Straw cells originating from the lungs, liver and lymphocytes have varying nodules, hairiness and dimensions. Lipid profiling reveals severe disruption of the plasma membrane in CACO cells during transformation. The growth rates for the elongation of filaments and enlargement of rabbit straw cells is 0.6~1.1 (μm/hr and 3.8 (μm3/hr, respectively. Studies using apoptosis inhibitors and a tubular transformation inhibitor in CACO2 cells and in mice suggested apoptosis produced apoptotic bodies are mediated differently than tubular transformation produced straw cells. A single dose of 0.01 mg/kg/day of p38 MAPK inhibitor in wild type mice results in a 30% reduction in the SBC. In 9 domestic animals SBC appears to correlate inversely with an animal's average lifespan (R2 = 0.7. Conclusion Straw cells are observed residing in the mammalian blood with large quantities. Production of SBC appears to be constant for a given animal and may involve a stress-inducible protein kinase (P38 MAPK. Tubular transformation is a programmed cell survival process that diverges from apoptosis

  19. Children's white blood cell counts in relation to developmental exposures to methylmercury and persistent organic pollutants

    DEFF Research Database (Denmark)

    Oulhote, Youssef; Shamim, Z; Kielsen, Katrine

    2017-01-01

    ), and total mercury (Hg) were measured in maternal (n = 56) and children's blood at 18 months (n = 42) and 5 years (n = 54). We constructed latent functions for exposures at three different ages using factor analyses and applied structural equation models adjusted for covariates. Results Prenatal mercury....... In contrast, the 5-year PFASs concentrations were associated with higher basophil counts (B = 46% SD, 95% CI: 13, 79). Significantly reduced subpopulations of lymphocytes such as B cells, CD4-positive T helper cells and CD4 positive recent thymic emigrants may suggest cellular immunity effects...... and dysregulation of T-cell mediated immunity. Conclusion Developmental exposure to environmental immunotoxicants appears to have different impacts on WBC counts in childhood....

  20. The effect of manual acupuncture on blood neutrophil counts in moderate intensity exercise

    Science.gov (United States)

    Ciang, C. Y.; Simadibrata, C.; Tobing, A.; Srilestari, A.

    2017-08-01

    Exercise, even though it has a beneficial effect, can cause muscle damage and trigger inflammatory responses, as evidenced by increased neutrophils in the blood. Acupuncture is a therapeutic modality that is expected to reduce acute inflammatory responses due to exercise. Thirty untrained men were divided randomly into two groups. The manual acupuncture group (n = 15) received stimulation at acupoints ST36 and SP6 bilateral by needle insertion, while the placebo group (n = 15) received insertion of needles on plaster without penetrating the skin. Therapy was done once for 30 minutes immediately after the subjects completed the exercise. Blood neutrophil counts were assessed before exercise and one hour after exercise ended. The results show there is a statistically significant difference in the number of neutrophils before and after exercise between the manual acupuncture group and the placebo group (0.08±0.91 and 0.97±0.70 p = 0.006). Acupuncture therapy effectively mitigates the acute inflammatory response triggered by exercise.

  1. Blood count and number of somatic cells in milk of cows infected with Coxiella burnetii

    Directory of Open Access Journals (Sweden)

    Radinović Miodrag

    2011-01-01

    Full Text Available The objective of the work was to examine the intensity of the local immune response of the mammary gland and the changes in the differential blood count of chronically infected cows. An experiment was performed on a group of cows with Q fever serologically proven using the ELISA test (IDEXX. Based on the ELISA test results, an experimental group of ten infected cows was formed. Blood was sampled from the experimental cows, and cumulative milk samples were taken. The number of erythrocytes was determined spectrophotometrically, and the number of leucocytes using the method according to Bürker - Türk. The blood analysis established an increased number of erythrocytes, while the number of leucocytes was within the limits of physiological values. The milk samples were used for the determination of the number of somatic cells using flow cytometric measurements. The processing of the milk samples established an average number of somatic cells of 853.000 /mL milk.

  2. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  3. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  4. Flow cytometric assessment of activation of peripheral blood platelets in dogs with normal platelet count and asymptomatic thrombocytopenia.

    Science.gov (United States)

    Żmigrodzka, M; Guzera, M; Winnicka, A

    2016-01-01

    Platelets play a crucial role in hemostasis. Their activation has not yet been evaluated in healthy dogs with a normal and low platelet count. The aim of this study was to determine the influence of activators on platelet activation in dogs with a normal platelet count and asymptomatic thrombocytopenia. 72 clinically healthy dogs were enrolled. Patients were allocated into three groups. Group 1 consisted of 30 dogs with a normal platelet count, group 2 included 22 dogs with a platelet count between 100 and 200×109/l and group 3 consisted of 20 dogs with a platelet count lower than 100×109/l. Platelet rich-plasma (PRP) was obtained from peripheral blood samples using tripotassium ethylenediaminetetraacetic acid (K3-EDTA) as anticoagulant. Next, platelets were stimulated using phorbol-12-myristate-13-acetate or thrombin, stabilized using procaine or left unstimulated. The expression of CD51 and CD41/CD61 was evaluated. Co-expression of CD41/CD61 and Annexin V served as a marker of platelet activation. The expression of CD41/CD61 and CD51 did not differ between the 3 groups. Thrombin-stimulated platelets had a significantly higher activity in dogs with a normal platelet count than in dogs with asymptomatic thrombocytopenia. Procaine inhibited platelet activity in all groups. In conclusion, activation of platelets of healthy dogs in vitro varied depending on the platelet count and platelet activator.

  5. Toward unstained cytology and complete blood counts at the point of care (Conference Presentation)

    Science.gov (United States)

    Zuluaga, Andres F.; Pierce, Mark C.; MacAulay, Calum E.

    2017-02-01

    Cytology tests, whether performed on body fluids, aspirates, or scrapings are commonly used to detect, diagnose, and monitor a wide variety of health conditions. Complete blood counts (CBCs) quantify the number of red and white blood cells in a blood volume, as well as the different types of white blood cells. There is a critical unmet need for an instrument that can perform CBCs at the point of care (POC), and there is currently no product in the US that can perform this test at the bedside. We have developed a system that is capable of tomographic images with sub-cellular resolution with consumer-grade broadband (LED) sources and CMOS detectors suitable for POC implementation of CBC tests. The systems consists of cascaded static Michelson and Sagnac interferometers that map phase (encoding depth) and a transverse spatial dimension onto a two-dimensional output plane. Our approach requires a 5 microliter sample, can be performed in 5 minutes or less, and does not require staining or other processing as it relies on intrinsic contrast. We will show results directly imaging and differentiating unstained blood cells using supercontinuum fiber lasers and LEDs as sources and CMOS cameras as sensors. We will also lay out the follow up steps needed, including image segmentation, analysis and classification, to verify performance and advance toward CBCs that can be performed bedside and do not require CLIA-certified laboratories.

  6. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, MM; Moes, H; van der Schaaf, G; de Leij, LFMH; Heineman, MJ

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  7. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, M. M.; Moes, H.; van der Schaaf, G.; de Leij, L. F. M. H.; Heineman, M. J.

    2003-01-01

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  8. Branched-chain amino acid-enriched nutrient increases blood platelet count in patients after endoscopic injection sclerotherapy.

    Science.gov (United States)

    Furuichi, Yoshihiro; Imai, Yasuharu; Miyata, Yuki; Sugimoto, Katsutoshi; Sano, Takatomo; Taira, Junichi; Kojima, Mayumi; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Moriyasu, Fuminori

    2016-10-01

    Protein and energy malnutrition is a severe problem for patients with liver cirrhosis (LC) and fasting often induces starvation which is a vitally important outcome. Dietary restriction is essential for endoscopic injection sclerotherapy (EIS) in patients with risky esophageal varices, thereby creating the possible exacerbation of nutritional state and inducing liver dysfunction. Whether EIS induces nutritional deficiency in LC patients and the effects of branched-chain amino acid (BCAA)-enriched nutrient are prospectively investigated. A total of 61 LC patients were randomly divided into an EIS monotherapy group (non-BCAA group, n = 31) and an EIS combined with BCAA therapy group (n = 30). Platelet count, blood chemistry and somatometry values were prospectively measured at five time points. The platelet counts before treatment were at the same level in both groups (P = 0.72). Three months after treatment, the counts decreased in the non-BCAA group; however, they increased in the BCAA group (P = 0.019). Body mass index, triceps skin fold thickness and arm muscle circumference significantly decreased in both groups. The BCAA and tyrosine ratio value increased only in the BCAA group (P BCAA group (P BCAA. Administration of BCAA had some effect in maintaining the nutritional state, and may improve the platelet count. Taking a greater amount of nutrients and shorter dietary restriction period or hospitalization was desirable. © 2016 The Japan Society of Hepatology.

  9. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Using frame count normalization method

    Energy Technology Data Exchange (ETDEWEB)

    Akanabe, Hiroshi; Oshima, Motoo; Sakuma, Sadayuki

    1988-07-01

    The assumption necessary to perform ECG gated blood pool scintigraphy (EGBPS) are seemingly not valid for patients with atrial fibrillation (af), since they have wide variability in cardiac cycle length. The data were acquired in frame mode within the limits of mean heart rate of fix the first diastolic volume, and were calculated by frame count normalization (FCN) method to correct total counts in each frame. EGBPS were performed twelve patients with af, who were operated against valvular disease. The data acquired within mean heart rate +-10 % in frame mode were divided to 32 frames, and calculated total frame counts. With FCN method total frame counts from at 22nd to 32nd frame were multiplied to be equal to the average of total frame counts. FCN method could correct total frame counts at the latter frames. And there was good correlation between left ventricular ejection fraction calculated from scintigraphy and that from contrast cineangiography. Thus EGBPS with FCN method may be allow estimation of cardiac function even in subjects with af.

  10. On Orbit Immuno-Based, Label-Free, White Blood Cell Counting System with MicroElectroMechanical Sensor (MEMS) Technology (OILWBCS-MEMS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences Corporation and partner, Draper Laboratory, propose to develop an on-orbit immuno-based label-free white blood cell counting system using MEMS...

  11. On Orbit Immuno-Based, Label-Free, White Blood Cell Counting System with MicroElectroMechanical Sensor (MEMS) Technology (OILWBCS-MEMS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences Corporation and our partner, Draper Laboratory, propose to develop an on orbit immuno-based, label-free, white blood cell counting system for...

  12. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  13. The Copenhagen primary care differential count (CopDiff) database

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, V.; Karlslund, W.

    2014-01-01

    BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore assoc...... the construction of the Copenhagen Primary Care Differential Count database as well as the distribution of characteristics of the population it covers and the variables that are recorded. Finally, it gives examples of its use as an inspiration to peers for collaboration.......BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore...... Practitioners' Laboratory has registered all analytical results since July 1, 2000. The Copenhagen Primary Care Differential Count database contains all differential blood cell count results (n=1,308,022) from July 1, 2000 to January 25, 2010 requested by general practitioners, along with results from analysis...

  14. White blood cell counts mediate the effects of physical activity on prostate-specific antigen levels.

    Science.gov (United States)

    Loprinzi, Paul D; Richart, Sarah M

    2014-09-01

    The purpose of this study was to examine whether white blood cell (WBC) level mediated the relationship between physical activity and prostate-specific antigen (PSA) levels. Data from the 2003-2006 National Health and Nutrition Examination Survey were used; 1,726 U.S. adult men (aged 40 years or older) provided complete data on the study variables. Participants wore an ActiGraph 7164 accelerometer for a 7-day period to measure their physical activity behavior, and PSA and WBC levels were obtained from a blood sample. After adjustments, results showed that moderate-to-vigorous physical activity (MVPA) was inversely associated with WBC count (b = - .03; 95% CI [ - 0.04, - 0.006; p = .01), and WBC count (b = .10; 95% CI [0.009, 0.18; p = .04) was positively associated with PSA. Both the Sobel (coef. = - .004, SE = .002; z = - 2.0; p = .03) and the Aroian (coef. = - .004, SE = .002; z = - 1.9; p = .03) tests demonstrated that WBC mediated the relationship between physical activity and PSA. Additionally, among 107 participants with prostate cancer, survivors engaging in more MVPA had lower levels of WBC (b = - .04; 95% CI [ - 0.09, - 0.0009; p = .04). Conclusion Physical activity may influence PSA levels through WBC modulation; however, future research is needed to determine the direction of causality. Additionally, prostate cancer survivors engaging in higher levels of MVPA had lower levels of WBC, underscoring the importance of promoting physical activity among prostate cancer survivors.

  15. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    Science.gov (United States)

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... Checking Your Blood Glucose A1C and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon ...

  17. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.

    Science.gov (United States)

    Ercan, Serif; Calışkan, Mustafa; Koptur, Erhan

    2014-01-01

    There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values. 70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values. First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed. We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.

  18. Keto analogues and amino acids supplementation induces a decrease of white blood cell counts and a reduction of muscle damage during intense exercise under thermoneutral conditions.

    Science.gov (United States)

    Lima, R C P; Camerino, S R A S; França, T C L; Rodrigues, D S A; Gouveia, M G S; Ximenes-da-Silva, A; Bassini, A; Prado, E S; Cameron, L C

    2017-04-19

    This study evaluated the acute effect of keto analogue and amino acid (AA-KAAA) supplementation on both white blood cell counts and the established biomarkers of muscle damage during exercise under thermoneutral conditions. Sixteen male cyclists received a ketogenic diet for two days and were divided into two equal groups: a group taking AA-KAAA (KA) or a control group (PL). The athletes performed a two hour cycling session followed by a maximum incremental test until voluntary exhaustion (VExh). Blood samples were obtained at rest and during exercise for further hematological and biochemical analyses. Exercise-induced ammonemia increased in the PL group at VExh (75%) but remained unchanged in the KA group. Both groups exhibited a significant increase in leukocyte and neutrophil counts of ∼85% (∼13 × 10 9 L -1 ), but the shape of the lymphocytes and the eosinophil counts suggest that AA-KAAA supplementation helps prevent lymphocytosis. AA-KAAA supplementation induced a decrease in creatine kinase and aspartate aminotransferase levels at VExh while showing a significant decrease in lactate dehydrogenase at 120 min. We found that AA-KAAA supplementation decreases both the lymphocyte count response in blood and the established biomarkers of muscle damage after intense exercise under a low heat stress environment.

  19. Cell type specific DNA methylation in cord blood: A 450K-reference data set and cell count-based validation of estimated cell type composition.

    Science.gov (United States)

    Gervin, Kristina; Page, Christian Magnus; Aass, Hans Christian D; Jansen, Michelle A; Fjeldstad, Heidi Elisabeth; Andreassen, Bettina Kulle; Duijts, Liesbeth; van Meurs, Joyce B; van Zelm, Menno C; Jaddoe, Vincent W; Nordeng, Hedvig; Knudsen, Gunn Peggy; Magnus, Per; Nystad, Wenche; Staff, Anne Cathrine; Felix, Janine F; Lyle, Robert

    2016-09-01

    Epigenome-wide association studies of prenatal exposure to different environmental factors are becoming increasingly common. These studies are usually performed in umbilical cord blood. Since blood comprises multiple cell types with specific DNA methylation patterns, confounding caused by cellular heterogeneity is a major concern. This can be adjusted for using reference data consisting of DNA methylation signatures in cell types isolated from blood. However, the most commonly used reference data set is based on blood samples from adult males and is not representative of the cell type composition in neonatal cord blood. The aim of this study was to generate a reference data set from cord blood to enable correct adjustment of the cell type composition in samples collected at birth. The purity of the isolated cell types was very high for all samples (>97.1%), and clustering analyses showed distinct grouping of the cell types according to hematopoietic lineage. We explored whether this cord blood and the adult peripheral blood reference data sets impact the estimation of cell type composition in cord blood samples from an independent birth cohort (MoBa, n = 1092). This revealed significant differences for all cell types. Importantly, comparison of the cell type estimates against matched cell counts both in the cord blood reference samples (n = 11) and in another independent birth cohort (Generation R, n = 195), demonstrated moderate to high correlation of the data. This is the first cord blood reference data set with a comprehensive examination of the downstream application of the data through validation of estimated cell types against matched cell counts.

  20. Nodal tumor response according to the count of peripheral blood lymphocyte subpopulations during preoperative chemoradiotherapy in locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jae Sung; Oh, Young Tae; Noh, O Kyu; Chun, Mi Son; Park, Jun Eun; Cho, Sung Ran [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2016-12-15

    The objective of this prospective study was to evaluate the relationship between the circulating lymphocyte subpopulation counts during preoperative chemoradiotherapy (CRT) and tumor response in locally advanced rectal cancer. From August 2015 to June 2016, 10 patients treated with preoperative CRT followed by surgery were enrolled. Patients received conventional fractionated radiotherapy (50.4 Gy) with fluorouracil-based chemotherapy. Surgical resection was performed at 4 to 8 weeks after the completion of preoperative CRT. The absolute blood lymphocyte subpopulation was obtained prior to and after 4 weeks of CRT. We analyzed the association between a tumor response and change in the lymphocyte subpopulation during CRT. Among 10 patients, 2 (20%) had evidence of pathologic complete response. In 8 patients with clinically node positive, 4 (50%) had nodal tumor response. All lymphocyte subpopulation counts at 4 weeks after CRT were significantly lower than those observed during pretreatment (p < 0.01). A high decrease in natural killer (NK) cell, count during CRT (baseline cell count - cell count at 4 weeks) was associated with node down staging (p = 0.034). Our results suggest that the change of lymphocyte subset to preoperative CRT may be a predictive factor for tumor response in rectal cancer.

  1. IMPACT OF 10 SESSIONS OF WHOLE BODY CRYOSTIMULATION ON AEROBIC AND ANAEROBIC CAPACITY AND ON SELECTED BLOOD COUNT PARAMETERS

    Directory of Open Access Journals (Sweden)

    Tomasz Dybek

    2012-01-01

    Full Text Available The systemic effect of low temperature suggests that sessions in a cryogenic chamber might improve athletes’ capacity as a standard element of training. Therefore the authors decided to evaluate the impact of 10 sessions of whole body cryostimulation (WBCT on aerobic and anaerobic efficiency as well as on selected blood count parameters. The study group included 32 volunteers – 16 women and 16 men. The volunteers underwent 10 sessions of WBCT in a cryogenic chamber. Blood samples (RBC, WBC, PLT, HGB, HCT were taken, and aerobic and anaerobic efficiency and lactate concentration in capillary blood were measured before the first session and one day after the last one. No significant differences were observed in values of aerobic capacity after 10 sessions of WBCT. There was a rising trend in men and a declining trend in women. The lactate concentration did not differ significantly before and after WBCT. A slight rise in aerobic and anaerobic threshold was observed in men, while in women the values slightly fell. The Wingate test showed no significant differences in results before and after cryostimulation. Only the TOBT was significantly shorter in men (6.12±1.49 vs 3.79±1.14 s. The WBCT sessions resulted in a significant rise of the haematological parameters both in women and men, excluding HCT, which showed a statistically insignificant rise. Ten sessions of whole body cryostimulation did not affect aerobic or anaerobic capacity in the tested group, although it improved the blood count parameters.

  2. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  3. The Full blood count and blood film (Haemogram)

    African Journals Online (AJOL)

    the possible results and what decisions might those results lead us to make?” Then we should ask ... iron (reduced), transferrin (reduced) and ferritin (normal or raised). There is no .... ('gingerbread men') on the blood film. malignant disease.

  4. Correlation of circulating MMP-9 with white blood cell count in humans: effect of smoking.

    Directory of Open Access Journals (Sweden)

    Soren Snitker

    Full Text Available Matrix metalloproteinase-9 (MMP-9 is an emerging biomarker for several disease conditions, where white blood cell (WBC count is also elevated. In this study, we examined the relationship between MMP-9 and WBC levels in apparently healthy smoking and non-smoking human subjects.We conducted a cross-sectional study to assess the relationship of serum MMP-9 with WBC in 383 men and 356 women. Next, we divided the male population (women do not smoke in this population into three groups: never (n = 243, current (n = 76 and former (n = 64 smokers and compared the group differences in MMP-9 and WBC levels and their correlations within each group.Circulating MMP-9 and WBC count are significantly correlated in men (R(2 = 0.13, p<0.001 and women (R(2 = 0.19, p<0.001. After stratification by smoking status, MMP-9 level was significantly higher in current smokers (mean ± SE; 663.3±43.4 ng/ml, compared to never (529.7±20.6 and former smokers (568±39.3. WBC count was changed in a similar pattern. Meanwhile, the relationship became stronger in current smokers with increased correlation coefficient of r = 0.45 or R(2 = 0.21 (p<0.001 and steeper slope of ß = 1.16±0.30 (p<0.001 in current smokers, compared to r = 0.26 or R(2 = 0.07 (p<0.001 and ß = 0.34±0.10 (p<0.001 in never smokers.WBC count accounts for 13% and 19% of MMP-9 variance in men and women, respectively. In non-smoking men, WBC count accounts for 7% of MMP-9 variance, but in smoking subjects, it accounts for up to 21% of MMP-9 variance. Thus, we have discovered a previously unrecognized correlation between the circulating MMP-9 and WBC levels in humans.

  5. Aqueous extract of Telfairia occidentalis leaves reduces blood sugar ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-07-18

    Jul 18, 2008 ... white blood cell counts), sperm parameters (sperm motility, viability and counts) and blood glucose were determined. ... cantly increased red blood cell count, white blood cell count, packed cell volume and .... improve sperm motility and fertility in smokers (Dawson et al., 1992) and boar (Ivos et al., 1971), ...

  6. The utility and cost-effectiveness of serial complete blood count monitoring in patients receiving radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Blank, Kenneth; Cascardi, Michelle; Kao, Gary D.

    1997-01-01

    Purpose/Objective: It has been a standard practice in our department to monitor weekly complete blood counts (CBC) in patients receiving pelvic radiation therapy for prostate cancer. The utility and cost-effectiveness of this practice has not been analyzed. Material and Methods: We analyzed 1572 separate CBCs performed on 110 consecutive outpatients treated at the Veterans Administration Medical Center, Philadelphia, PA from June 1994 to June 1996 for localized prostate cancer. 92 of these patients fulfilled the study inclusion criteria of blood counts on at least four different weeks of treatment, a baseline hemoglobin (pretreatment or week one of radiation therapy), and at least one CBC after week four. Complete data was subjected to chi-square statistical analysis of factors including age, field size, concomitant hormonal therapy and the presence of hypertension or diabetes. Results: The mean hemoglobin level at the beginning of treatment of was 13.2 grams/dl (gms) and mean change in hemoglobin from baseline to the last week of treatment was - 0.53 gms (range +2.0 to -3.5 gm). No patients required blood transfusion or erythropoeitin treatment, and only five patients experienced declines of >2.0 gms (-2.1, -2.3, -2.5, -2.9 and -3.5). Two of these patients sustained the hemoglobin declines concomitantly with congestive heart failure requiring intensive care unit admission (suggesting fluid overload). The hemoglobin level in the remaining patients has returned to normal without treatment by one month after the end of radiation. No significant differences were found between the group of patients that dropped more than 1.0 gm (n=34) and the group that did not (n = 58) in field size (p0.08), presence of diabetes (p= 0.48) or hypertension (p= 0.43), concurrent or prior hormone therapy (p= 0.37), or age (p=0.83). No consistent trends in white blood cell or platelet counts could be detected during radiation and no patients had white blood cells counts fall below 2000/mm

  7. Correlation of routine haematological parameters between normal maternal blood and the cord blood of healthy newborns in selected hospitals of karachi

    International Nuclear Information System (INIS)

    Qaiser, D.H.; Ghori, G.M.; Sandila, M.P.; Omair, A.

    2013-01-01

    Objective: To determine any significant correlation between the routine haematological parameters of maternal blood and umbilical cord blood of their respective newborns. Study Design: Cross sectional study. Place and Duration of Study: The study was conducted at four public and private hospitals of Karachi including Sindh Government Qatar Hospital, Sindh Government Hospital, Liaquatabad, Ziauddin University Hospital and Chinniot Maternity and Child Hospital, respectively from July 2006 to April 2008. Methodology: Three milliliters venous blood was collected in EDTA containing tube for complete blood count of mothers before delivery. Five milliliters cord blood was collected from the umbilical cord of the babies immediately after delivery by clamping and cutting the babies' end of the cord. For haematological parameters a standard coultergram was done including haemoglobin, RBCs count, haematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH), mean corpuscular haemoglobin concentration (MCHC), white blood cell count, differential leukocyte count and platelet count. Pearson's correlation co-efficient was used to determine an association between the maternal and cord blood parameters. Results: A total of 404 maternal and umbilical cord blood samples were analyzed. All the blood parameters including haemoglobin, RBCs count, HCT, MCV, MCH, white blood cell count, differential leukocyte count and platelet count were found to be high in cord blood as compared to the maternal blood, but they showed a very weak to negligible correlation. Mean Corpuscular Haemoglobin Concentration (MCHC), showed a moderate correlation. Conclusion: Routine haematological parameters of newborns are independent of maternal routine haematological parameters. (author)

  8. Blood Culture (For Parents)

    Science.gov (United States)

    ... Metabolic Panel (BMP) Blood Test: Complete Blood Count Basic Blood Chemistry Tests Getting a Blood Test (Video) Blood Test: Basic Metabolic Panel Blood Test: Comprehensive Metabolic Panel Blood ...

  9. Studies on the chronological alterations of blood counts on the radiological technicians at health centers in Japan (1957 - 1975)

    International Nuclear Information System (INIS)

    Endo, Kouichi; Ishizaka, Masatsuna

    1977-01-01

    From the nine health surveys made on clinical radiation technicians working at health centers during the 18 years from 1957 to 1975, 679 technicians on whom blood examinations were made for not less than ten consecutive years were sampled to investigate for chronological alterations in their blood parameters. The radiation protective means at the health centers have made rapid progress ever since the atomic bomb experiment in 1954, and the dose of exposure to radiation then began to decrease. On the other hand, it was in about 1960 that the measurement of individual exposure doses began to be made on 60% of all the technicians. Chronological alterations in the average blood counts of these technicians under the abovementioned situation were such that RBC and hemoglobin level continued to increase from 1963 until about 1967, but then began to decrease, and that WBC was as low as 5,883/mm 3 in 1957, but tended to increase though slightly at each of the subsequent surveys, and was increased to 6,570/mm 3 in 1975, that is, WBC has been approaching the normal count of 6,774/mm 3 in the Japanese, with a significant difference at a not more than 1% level of significance in each survey year. For the purpose of preventing radiation hazard, further efforts should be made to protect the technicians from exposure to radiation and to control their health. (auth.)

  10. Effect of laser on human blood

    International Nuclear Information System (INIS)

    Abdalsamad, Amuna Nagash Mohammed

    2016-03-01

    In this work, the effect of He-Ne (632.8 nm), N2 (337.1 nm), LED (450 nm) on the human blood, and blood component was studied by using CBC machine ( complete blood count) and UV -visible spectroscopy. Blood samples platoon A+ were collected and irradiated for different periods of time (10 minute, 20 minute, and 30 minute), to varied types of light source ( He- Ne laser and LED). Blood parameters of samples were measured by using complete Blood Count Machine (CBC). The absorption spectrum of blood samples were examined by using UV-visible spectrometer. The obtained results have shown different values of Complete Blood Counts and absorption spectrum due to different laser types and periods of time. We conclude that the laser light has clear effect on blood samples. (Author)

  11. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  12. Fatigue, serum cytokine levels, and blood cell counts during radiotherapy of patients with breast cancer

    International Nuclear Information System (INIS)

    Geinitz, Hans; Zimmermann, Frank B.; Stoll, Peter; Thamm, Reinhard; Kaffenberger, Walter; Ansorg, Kai; Keller, Monika; Busch, Raymonde; Beuningen, Dirk van; Molls, Michael

    2001-01-01

    Purpose: To assess the level of fatigue during the course of adjuvant radiotherapy (RT) of breast cancer patients and its relation to anxiety, depression, serum cytokines, and blood count levels. Methods and Materials: Forty-one patients who received adjuvant RT after breast-conserving surgery were prospectively studied. All patients underwent RT without concomitant chemotherapy. Patients rated their fatigue with two standardized self-assessment instruments, the Fatigue Assessment Questionnaire and a visual analog scale on fatigue intensity, before RT, during weeks 1-5 of RT, and 2 months after RT completion. In addition, the anxiety and depression levels were assessed with the Hospital Anxiety and Depression Scale. A differential blood cell count and the serum levels of the cytokines interleukin (IL)-1β, IL-6, and tumor necrosis factor-α were determined in parallel to the fatigue assessments. Results: Fatigue intensity as assessed with the visual analog scale increased (p<0.001) until treatment week 4 and remained elevated until week 5. Two months after RT, the values had fallen to the pretreatment levels. Fatigue measured with the Fatigue Assessment Questionnaire did not increase significantly during treatment, but the subscores on physical (p=0.035) and cognitive (p=0.015) fatigue were elevated during treatment weeks 4 and 5. Affective fatigue did not change significantly. Anxiety, as rated with the Hospital Anxiety and Depression Scale, declined during RT (p=0.002), but the Hospital Anxiety and Depression Scale depression score did not change significantly. IL-1β, IL-6, and tumor necrosis factor-α levels did not change during therapy and did not correlate with fatigue. Peripheral blood cell levels declined significantly during therapy and were still low 2 months after treatment. Until treatment week 5, lymphocytes were reduced to almost 50% of their initial values. Hemoglobin levels did not correlate with fatigue. Conclusions: We observed an increase in

  13. Study on serum TNF-α level, B-cell count and T-cell subsets distribution in peripheral blood in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Shi Buqing

    2006-01-01

    Objective: To study the changes of serum TNF-α levels, B-cell count and T-cell subsets distribution in peripheral blood in patients with rheumatoid arthritis. Methods: Serum TNF-α levels (with RIA), B cell as well as T cell subsets distribution type (with monoclonal antibody technique) were examined in 37 patients with rheumatoid arthritis and 30 controls. Results Serum TNF-α levels and B lymphocytes count were significantly higher in the patients than those in controls (P 3 , CD 4 and CD 4 /CD 8 were obviously lower (P<0.01). Conclusion: Rheumatoid arthritis is an autoimmune disease with abnormal immunoregulation. (authors)

  14. Further investigations on the influence of ultraviolet irradiation on blood corpuscles hemoglobin content and differential leucocyte count in the chicken

    International Nuclear Information System (INIS)

    Bolukbasi, F.

    1978-01-01

    The influence of ultraviolet irradiation, applied for one hour, with a relatively high enerqy output of 95.5x10 3 erg. cm -2 . sn -1 , on some biological parameters of chicken's blood was determined. At the 24th hour after irradiation erythrocyte count, hemoglobin content and percentages of lymphocytes, monocytes, eosinophils and basophils were decreased, but total leucocyte, thrombocyte counts and percentage of pseudoeosinophils were increased, significantly (P< 0,01). No significant changes were obtained in all parameters, at the 24th hour after a second irradiation. There were also found no differences between the values obtained at 24th hour after the second, and at 48th hour after the single irradiation, but all these values had a tendency taward the initial determinations

  15. Development of a Prognostic Score Using the Complete Blood Cell Count for Survival Prediction in Unselected Critically Ill Patients

    OpenAIRE

    Chongliang, Fang; Yuzhong, Li; Qian, Shi; Xiliang, Liu; Hui, Liu

    2013-01-01

    Objective. The purpose of this study was to develop a new prognostic scoring system for critically ill patients using the simple complete blood cell count (CBC). Methods. CBC measurements in samples from 306 patients in an intensive care unit were conducted with automated analyzers, including levels of neutrophils, lymphocytes, erythrocytes, hemoglobin, and platelets. The time of sampling and the time of death were recorded. Z values were calculated according to the measured values, reference...

  16. Relationship between high white blood cell count and insulin resistance (HOMA-IR) in Korean children and adolescents: Korean National Health and Nutrition Examination Survey 2008-2010.

    Science.gov (United States)

    Park, J-M; Lee, D-C; Lee, Y-J

    2017-05-01

    Increasing evidence has indicated that insulin resistance is associated with inflammation. However, few studies have investigated the association between white blood cell (WBC) count and insulin resistance, as measured by a homeostasis model assessment of insulin resistance (HOMA-IR) in a general pediatric population. This study aimed to examine the association between WBC count and insulin resistance as measured by HOMA-IR in a nationally representative sample of children and adolescents. In total, 2761 participants (1479 boys and 1282 girls) aged 10-18 years were selected from the 2008-2010 Korean National Health and Nutrition Examination Survey. Insulin resistance was defined as a HOMA-IR value greater than the 90th percentile. The odds ratios and 95% confidence intervals for insulin resistance were determined using multiple logistic regression analysis. The mean values of most cardiometabolic variables tended to increase proportionally with WBC count quartiles. The prevalence of insulin resistance significantly increased in accordance with WBC count quartiles in both boys and girls. Compared to individuals in the lowest WBC count quartile, the odds ratio for insulin resistance for individuals in the highest quartile was 2.84 in boys and 3.20 in girls, after adjusting for age, systolic blood pressure, body mass index, and waist circumference. A higher WBC count was positively associated with an increased risk of insulin resistance in Korean children and adolescents. This study suggests that WBC count could facilitate the identification of children and adolescents with insulin resistance. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  17. Blood and Diversity

    Science.gov (United States)

    ... Drive Biomedical Services Hospital Partners Blood Products Blood Banking Resources Order Blood Products Invoice Central Case Reports ... app (over 1 million downloads and counting!) and online scheduler make it quick to set up your ...

  18. White blood cell count - series (image)

    Science.gov (United States)

    ... the hand. The puncture site is cleaned with antiseptic, and a tourniquet (an elastic band) or blood ... or young child: The area is cleansed with antiseptic and punctured with a sharp needle or a ...

  19. Polycystic ovary syndrome and the peripheral blood white cell count.

    LENUS (Irish Health Repository)

    Herlihy, A C

    2012-02-01

    This retrospective cross-sectional study examined if the white cell count (WCC) is increased in women with polycystic ovary syndrome (PCOS) and if so, is it due to PCOS or to the associated obesity? Body mass index (BMI) was calculated and body composition was measured using bioelectrical impedance analysis. Of the 113 women studied, 36 had PCOS and 77 did not. The mean WCC was higher in the PCOS group compared with the non-PCOS group (8.9 x 10(9)\\/l vs 7.4 x 10(9)\\/l p = 0.002). This increase was due to a higher neutrophil count (5.6 x 10(9)\\/l vs 4.3 x 10(9)\\/l; p = 0.003). There was a leucocytosis (WCC >11 x 10(9)\\/l) present in 19% of the PCOS group compared with 1% in the non-PCOS group (p < 0.001). The neutrophil count was abnormally high (>7.7 x 10(9)\\/l) in 14% of the PCOS group compared with 4% in the non-PCOS group (p < 0.001). On regression analysis, however, the only independent variable which explained both the increased WCC and the increased neutrophil count was PCOS. We found that PCOS is associated with an increased WCC due to increased neutrophils, which supports the evidence that PCOS is associated with low-grade inflammation. The increase appears to be due to the underlying PCOS, and not to the increased adiposity associated with PCOS.

  20. Accuracy of Platelet Counting by Optical and Impedance Methods in Patients with Thrombocytopaenia and Microcytosis

    Directory of Open Access Journals (Sweden)

    Mohamed-Rachid Boulassel

    2015-11-01

    Full Text Available Objectives: Obtaining accurate platelet counts in microcytic blood samples is challenging, even with the most reliable automated haematology analysers. The CELL-DYN™ Sapphire (Abbott Laboratories, Chicago, Illinois, USA analyser uses both optical density and electronic impedance methods for platelet counting. This study aimed to evaluate the accuracy of optical density and electrical impedance methods in determining true platelet counts in thrombocytopaenic samples with microcytosis as defined by low mean corpuscular volume (MCV of red blood cells. Additionally, the impact of microcytosis on platelet count accuracy was evaluated. Methods: This study was carried out between February and December 2014 at the Haematology Laboratory of the Sultan Qaboos University Hospital in Muscat, Oman. Blood samples were collected and analysed from 189 patients with thrombocytopaenia and MCV values of <76 femtolitres. Platelet counts were tested using both optical and impedance methods. Stained peripheral blood films for each sample were then reviewed as a reference method to confirm platelet counts. Results: The platelet counts estimated by the impedance method were on average 30% higher than those estimated by the optical method (P <0.001. The estimated intraclass correlation coefficient was 0.52 (95% confidence interval: 0.41–0.62, indicating moderate reliability between the methods. The degree of agreement between methods ranged from -85.5 to 24.3 with an estimated bias of -30, suggesting that these methods generate different platelet results. Conclusion: The impedance method significantly overestimated platelet counts in microcytic and thrombocytopaenic blood samples. Further attention is therefore needed to improve the accuracy of platelet counts, particularly for patients with conditions associated with microcytosis.

  1. Basal CD34+ Cell Count Predicts Peripheral Blood Stem Cell Mobilization in Healthy Donors after Administration of Granulocyte Colony-Stimulating Factor: A Longitudinal, Prospective, Observational, Single-Center, Cohort Study.

    Science.gov (United States)

    Martino, Massimo; Gori, Mercedes; Pitino, Annalisa; Gentile, Massimo; Dattola, Antonia; Pontari, Antonella; Vigna, Ernesto; Moscato, Tiziana; Recchia, Anna Grazia; Barilla', Santina; Tripepi, Giovanni; Morabito, Fortunato

    2017-07-01

    A longitudinal, prospective, observational, single-center, cohort study on healthy donors (HDs) was designed to identify predictors of CD34 + cells on day 5 with emphasis on the predictive value of the basal CD34 + cell count. As potential predictors of mobilization, age, sex, body weight, height, blood volume as well as white blood cell count, peripheral blood (PB) mononuclear cells, platelet count, hematocrit, and hemoglobin levels were considered. Two different evaluations of CD34 + cell counts were determined for each donor: baseline (before granulocyte colony-stimulating factor [G-CSF] administration) and in PB after G-CSF administration on the morning of the fifth day (day 5). A total of 128 consecutive HDs (66 males) with a median age of 43 years were enrolled. CD34 + levels on day 5 displayed a non-normal distribution, with a median value of 75.5 cells/µL. To account for the non-normal distribution of the dependent variable, a quantile regression analysis to predict CD34 + on day 5 using the baseline value of CD34 + as the key predictor was performed. On crude analysis, a baseline value of CD34 + ranging from .5 cells/µL to 1 cells/µL predicts a median value of 50 cells/µL on day 5; a value of 2 cells/µL predicts a median value of 70.7 cells/µL; a value of 3 cells/µL to 4 cells/µL predicts a median value of 91.3 cells/µL, and a value ≥ 5 predicts a median value of 112 cells/µL. In conclusion, the baseline PB CD34 + cell count correlates with the effectiveness of allogeneic PB stem cell mobilization and could be useful to plan the collection. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  2. A retrospective analysis of the impact of treatments and blood counts on survival and the risk of vascular events during the course of polycythaemia vera

    DEFF Research Database (Denmark)

    Enblom-Larsson, Anneli; Girodon, Francois; Bak, Marie

    2017-01-01

    Vascular and non-vascular complications are common in patients with polycythaemia vera. This retrospective study of 217 patients with polycythaemia vera aimed to determine whether blood counts with respect to different treatments influenced the complication rate and survival. We found that 78 (36...

  3. Leukocytic Response and Peripheral Venous Blood Lymphocyte Apoptosis as a Marker of Tissue Ischemia in Acute Massive Blood Loss

    Directory of Open Access Journals (Sweden)

    N. V. Borovkova

    2013-01-01

    Full Text Available Objective: to estimate the level of peripheral venous blood lymphocyte apoptosis and intraoperative hypoxia in victims with acute massive blood loss. Subjects and methods. Twenty-two patients with open and close chest and abdominal traumas complicated by acute massive blood loss were examined. All the patients were emergently operated on to stop bleeding. Tissue metabolism was evaluated from gases, acid-base parameters, and plasma lactate, glucose, potassium, and sodium levels. Apoptosis of mononuclear cells was studied and dead leukocytes were counted using flow cytometry. Results. Preoperatively, the victims were found to have venous hypoxemia, hyperlactatemia, hyperglycemia, moderate leukocytosis, and higher dead leukocyte counts. There were also raised counts of lymphocytes coming into the process of apoptosis. A significant relationship was found between monocyte counts and hypoxia values. At the end of surgery, oxygen balance values became stable and exerted an effect on the count of leukocytes, the relative level of granulocytes, the relative and absolute counts of dead and damaged leukocytes, and the concentration of lymphocytes in the victims’ venous blood during the early stages of apoptosis, as evidenced by nonlinear regression models. Conclusion. The indicators of immunocompetent cell apoptosis and the count of venous blood dead leukocytes along with lactate levels and venous hypoxemia parameters reflect the degree of tissue hypoxia and may be used as specific markers.

  4. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  5. Decline of blood leukocyte counts 1947-59, Hiroshima and Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Ichimaru, Michito; Ueda, Shoichi; Blaisdell, R K

    1963-03-03

    Earlier reports of progressive decline in leukocyte counts in Hiroshima from about 1948 to 1954 have been confirmed. A similar phenomenon has been observed in Nagasaki. Analysis indicates that this decline in white cell count with time is not related to exposure to the 1945 atomic bombs, to sex, to age, to commonly diagnosed diseases, or to the disproportionate influence of a subgroup. The principal white cells affected were neutrophils, lymphocytes and eosinophils. The precise etiologic factors accounting for the decline, and the biological significance of the present lower range of leukocyte values in Hiroshima and Nagasaki remain to be determined. 16 references, 5 figures, 5 tables.

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get ... the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has ...

  7. Amylase and blood cell-count hematological radiation-injury biomarkers in a rhesus monkey radiation model-use of multiparameter and integrated biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, W.F. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: blakely@afrri.usuhs.mil; Ossetrova, N.I.; Manglapus, G.L.; Salter, C.A.; Levine, I.H.; Jackson, W.E.; Grace, M.B.; Prasanna, P.G.S.; Sandgren, D.J.; Ledney, G.D. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2007-07-15

    Effective medical management of suspected radiation exposure incidents requires the recording of dynamic medical data (clinical signs and symptoms), biological assessments of radiation exposure, and physical dosimetry in order to provide diagnostic information to the treating physician and dose assessment for personnel radiation protection records. The need to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios prompted an evaluation of suitable biomarkers that can provide early diagnostic information after exposure. We investigated the utility of serum amylase and hematological blood-cell count biomarkers to provide early assessment of severe radiation exposures in a non-human primate model (i.e., rhesus macaques; n=8) exposed to whole-body radiation of {sup 60}Co-gamma rays (6.5 Gy, 40cGymin{sup -1}). Serum amylase activity was significantly elevated (12.3{+-}3.27- and 2.6{+-}0.058-fold of day zero samples) at 1 and 2-days, respectively, after radiation. Lymphocyte cell counts decreased ({<=}15% of day zero samples) 1 and 2 days after radiation exposure. Neutrophil cell counts increased at day one by 1.9({+-}0.38)-fold compared with levels before irradiation. The ratios of neutrophil to lymphocyte cell counts increased by 13({+-}2.66)- and 4.23({+-}0.95)-fold at 1 and 2 days, respectively, after irradiation. These results demonstrate that increases in serum amylase activity along with decreases of lymphocyte counts, increases in neutrophil cell counts, and increases in the ratio of neutrophil to lymphocyte counts 1 day after irradiation can provide enhanced early triage discrimination of individuals with severe radiation exposure and injury. Use of the biodosimetry assessment tool (BAT) application is encouraged to permit dynamic recording of medical data in the management of a suspected radiological casualty.

  8. Changes in total and differential white cell counts, total lymphocyte ...

    African Journals Online (AJOL)

    Background: Published reports on the possible changes in the various immune cell populations, especially the total lymphocyte and CD4 cell counts, during the menstrual cycle in Nigerian female subjects are relatively scarce. Aim: To determine possible changes in the total and differential white blood cell [WBC] counts, ...

  9. Cord blood full blood count parameters in Lagos, Nigeria | Adewumi ...

    African Journals Online (AJOL)

    Due to its usefulness in the assessment of health status of individuals, its parameters in cord blood, a major source of haemopoietic stem cell transplantation and an ideal source for laboratory investigations for newborns were determined to provide a useful guide to local neonatologists and stem cell transplant physicians.

  10. The effects of Anadara granosa shell-Stichopus hermanni on bFGF expressions and blood vessel counts in the bone defect healing process of Wistar rats

    Directory of Open Access Journals (Sweden)

    Rima Parwati Sari

    2017-12-01

    Full Text Available Background: Bone damage can be caused by various factors with treatment usually involving graft materials being applied to the defective area. Moreover, in the bone defect healing process, blood vessels are also considered to be an important energy source for cell proliferation. One of the angiogenic factors playing an important role in blood vessel formation is basic fibroblast growth factor (bFGF. Furthermore, synthesized hydroxyapatite derived from Anadara granosa (AG shells constitutes one of the potential materials for use in bone graft. The gold sea cucumber genus Stichopus hermanni (SH possesses the ability to stimulate endothelial progenitor cells inducing bFGF. Purpose: This study aims to investigate the effects of AG shells and SH on bFGF expressions and blood vessel counts within the bone healing process. Methods: Twenty four male Wistar rats were divided into three groups, namely: a control group (C, a treatment group was administered with blood cockle shell (AG, and a treatment group with blood cockle shell and golden sea cucumber (AG+SH. Defects were made on their femurs measuring half the diameter of a circular, no. 018. bur These rats were subsequently sacrificed on day 7 after surgery. The expressions of bFGF were measured by means of IHC technique, while the number of blood vessels was quantified using HE technique. The resulting data was subjected to statistical analysis using an Anova test followed by an LSD test (p < 0.05. Results: The one-way Anova test results combined with those of an LSD test showed there to be significant differences in bFGF expressions and blood vessel counts between the control group (K and the treatment group (AG as well as between the treatment group (AG and the treatment group (AG+SH. Conclusions: A combination of Anadara granosa shell and Stichopus hermanni can increase the expression of bFGF and the number of blood vessels on day 7 during the bone healing process in Wistar rats.

  11. Characteristics of Febrile Patients with Normal White Blood Cell Counts and High C-Reactive Protein Levels in an Emergency Department

    Directory of Open Access Journals (Sweden)

    Kuan-Ting Liu

    2008-05-01

    Full Text Available Fever is one of the more common chief complaints of patients who visit emergency departments (ED. Many febrile patients have markedly elevated C-reactive protein (CRP levels and normal white blood cell (WBC counts. Most of these patients have bacterial infection and no previous underlying disease of impaired WBC functioning. We reviewed patients who visited our ED between November 2003 and July 2004. The WBC count and CRP level of patients over 18 years of age who visited the ED because of or with fever were recorded. Patients who had normal WBC count (4,000–10,000/mL and high CRP level (> 100 mg/L were included. The data, including gender, age and length of hospital stay, were reviewed. Underlying diseases, diagnosis of the febrile disease and final condition were recorded according to the chart. Within the study period, 54,078 patients visited our ED. Of 5,628 febrile adults, 214 (3.8% had elevated CRP level and normal WBC count. The major cause of febrility was infection (82.24%. Most of these patients were admitted (92.99%. There were 32 patients with malignant neoplasm, nine with liver cirrhosis, 66 with diabetes mellitus and 11 with uremia. There were no significant differences in age and gender between patients with and those without neoplasm. However, a higher inhospital mortality rate and other causes of febrility were noted in patients with neoplasm. It was not rare in febrile patients who visited the ED to have a high CRP level but normal WBC count. These patients did not necessarily have an underlying malignant neoplasm or hematologic illness. Factors other than malignant neoplasm or hematologic illness may be associated with the WBC response, and CRP may be a better indicator of infection under such conditions.

  12. Effect of indomethacin, diclofenac sodium and sodium salicylate on peripheral blood cell counts in sublethally gamma-irradiated mice

    International Nuclear Information System (INIS)

    Pospisil, M.; Netikova, J.; Kozubik, A.; Pipalova, I.

    1989-01-01

    Treatment with indomethacin and diclofenac sodium was found to increase granulocyte counts in the blood of sublethally gamma-irradiated mice. Treatment with sodium salicylate was ineffective in this respect, administration of sodium salicylate together with indomethacin even decreased the indomethacin-induced effects. The results suggest that the hemopoiesis-stimulating effects of non-steroidal anti-flammatory drugs cannot be correlated with the anti-inflammatory activity but rather with the side effects of these compounds, including the action on gastro-intestinal prostanoid production. This conclusion doubts on the possibility of the usefulness of non-steroidal anti-inflammatory drugs in conditions of the radiation syndrome. (orig.) [de

  13. Intravenous Tissue Plasminogen Activator Can Be Safely Given without Complete Blood Count Results Back.

    Directory of Open Access Journals (Sweden)

    Yi Dong

    Full Text Available It is well known that the efficacy of intravenous (i.v. tissue plasminogen activator (tPA is time-dependent when used to treat patients with acute ischemic strokes.Our study examines the safety issue of giving IV tPA without complete blood count (CBC resulted.This is a retrospective observational study by examining the database from Huashan Hospital in China and OSF/INI Comprehensive Stroke Center in United States. Patient data collected included demographics, occurrence of symptomatic intracranial hemorrhage, door to needle intervals, National Institute of Health Stroke Scale scores on admission, CBC results on admission and follow-up modified Rankin Scale scores. Linear regression and multivariable logistic regression analysis were used to identify factors that would have an impact on door-to-needle intervals.Our study included 120 patients from Huashan Hospital and 123 patients from INI. Among them, 36 in Huashan Hospital and 51 in INI received i.v. tPA prior to their CBC resulted. Normal platelet count was found in 98.8% patients after tPA was given. One patient had thrombocytopenia but no hemorrhagic event. A significantly shorter door to needle interval (DTN was found in the group without CBC resulted. There was also a difference in treatment interval between the two hospitals. Door to needle intervals had a strong correlation to onset to treatment intervals and NIHSS scores on admission.In patients presented with acute ischemic stroke, the risk of developing hemorrhagic event is low if i.v. tPA is given before CBC has resulted. The door to needle intervals can be significantly reduced.

  14. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    International Nuclear Information System (INIS)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki; Itoh, Haruki; Taniguchi, Koichi.

    1993-01-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: 1) Cut-off level was fixed at 70% of first channel, 2) Cut-off level at 75%, and 3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author)

  15. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki (Tokyo Medical and Dental Univ. (Japan). School of Medicine); Itoh, Haruki; Taniguchi, Koichi

    1993-06-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: (1) Cut-off level was fixed at 70% of first channel, (2) Cut-off level at 75%, and (3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author).

  16. The increase in leucocyte count during menstruation is a function of ...

    African Journals Online (AJOL)

    Menstruation is an endocrine mediated physiologic cyclical bleeding per vagina in a non-pregnant woman of the reproductive age group. Blood is a good culture medium for bacteria and as such, menstruation can affect leucocytes count. This study is aimed at evaluating leucocytes count during menstruation. Fifty-eight ...

  17. Hemoglobin, red blood cell count, hematocrit and derived parameters for diagnosing anemia in elderly males

    International Nuclear Information System (INIS)

    Khan, Z.; Nawaz, M.

    2013-01-01

    Anemia is one of the most common micronutrient deficiency in our community. Nutritional anaemias are caused when there is an inadequate body store of a specific nutrient needed for hemoglobin synthesis. The most common nutrient deficiency is of iron. Therefore, a cross-sectional survey was conducted on the healthy elderly male, aged >= 40 and 77 years (n=60) volunteers in order to assess their blood parameters, such as hemoglobin concentration (Hb), hematocrit (HCT), red blood cell count (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) for the diagnosis of anemia. The demographic results showed mean values (50.10+-8.79) years for age, 66-68 +- 1.95 inches for height , 71.43 +- 6.43 kg body weight, 98.34+-0.48 degree F body temperature, 124 +- 8.67 systolic blood pressure, 82.17 +- 4.15 diastolic pressure while, The pulse rate was found to be 74.63 +- 7.02/minute. Similarly, mean values for lean body weight (LBW) found to be 49.9+-2.89, ideal body weight (IBW) 60.9 +- 4.49, body surface area (BSA) was 1.8 +- 0.1 m2 whereas, body mass index (BMI) showed mean value 24.9 +- 2.6 kg/m2. More so, overall mean Hb found to be 13.60 g/dl, RBC 4.6 mill/mm3, HCT/PCV 43%, MCV 92.95fl, MCH 29.42 pg and MCHC was found to be 31.73 g/dl. The normal range of Hb for men was 13-17 g/dl and 31.67% of the subjects participated in the study was considered to be anemic showing less Hb than normal range. The volunteers were suggested to improve the dietary habits and to take iron supplements in order to overcome the iron deficiency anemia. (author)

  18. Psychosocial factors and T lymphocyte counts in Brazilian peacekeepers.

    Science.gov (United States)

    Silva, Angela M Monteiro da; Speranza, Francisco A B; Ishii, Solange Kiyoko; Hirata, Raphael; Mattos-Guaraldi, Ana Luíza; Milagres, Lucimar Gonçalves

    2015-02-01

    To investigate the associations between psychosocial factors and peripheral blood CD4 and CD8 T lymphocyte numbers in Brazilian peacekeepers. Venous blood was collected from 759 peacekeepers who had just returned from a peace mission in Haiti. Among the 759 soldiers, 642 individuals completed the psychosocial measures. CD4 and CD8 T lymphocyte counts were measured by flow cytometry using a commercially available kit. Psychosocial factors, including military peace force stressors, clinical stress, anxiety and depression, were recorded. As a reference for T lymphocyte numbers, we measured T lymphocyte counts in 75 blood donors from the Instituto de Biologia do Exército, Rio de Janeiro. The median numbers of CD4 and CD8 T lymphocytes in the blood donors were 819 cells/µl and 496 cells/µl, respectively, with a CD4:CD8 ratio of 1.6. Significantly (p<0.05) lower CD4 T cell counts (759 cells/µl) were recorded for peacekeepers, with similar CD8 levels (548 cells/µl) and smaller CD4:CD8 ratios (1.3, p<0.001) compared to blood donors. These differences were due to a group of 14 military personnel with CD4 and CD8 medians of 308 and 266 cells/µl, respectively. Only one (7.1%) of these 14 individuals was diagnosed with clinical stress compared with 13.5% of the individuals with normal levels of CD4 T lymphocytes. One individual out of 628 (0.16%) had a Lipp's Stress Symptom Inventory score of 3, indicating near exhaustion. The prevalence of psychological disorders was low and there were no associations with CD4 or CD8 T cell numbers.

  19. Depression and anxiety symptoms are associated with white blood cell count and red cell distribution width: A sex-stratified analysis in a population-based study.

    Science.gov (United States)

    Shafiee, Mojtaba; Tayefi, Maryam; Hassanian, Seyed Mahdi; Ghaneifar, Zahra; Parizadeh, Mohammad Reza; Avan, Amir; Rahmani, Farzad; Khorasanchi, Zahra; Azarpajouh, Mahmoud Reza; Safarian, Hamideh; Moohebati, Mohsen; Heidari-Bakavoli, Alireza; Esmaeili, Habibolah; Nematy, Mohsen; Safarian, Mohammad; Ebrahimi, Mahmoud; Ferns, Gordon A; Mokhber, Naghmeh; Ghayour-Mobarhan, Majid

    2017-10-01

    Depression and anxiety are two common mood disorders that are both linked to systemic inflammation. Increased white blood cell (WBC) count and red cell distribution width (RDW) are associated with negative clinical outcomes in a wide variety of pathological conditions. WBC is a non-specific inflammatory marker and RDW is also strongly related to other inflammatory markers. Therefore, we proposed that there might be an association between these hematological inflammatory markers and depression/anxiety symptoms. The primary objective of this study was to examine the association between depression/anxiety symptoms and hematological inflammatory markers including WBC and RDW in a large population-based study. Symptoms of depression and anxiety and a complete blood count (CBC) were measured in 9274 participants (40% males and 60% females) aged 35-65 years, enrolled in a population-based cohort (MASHAD) study in north-eastern Iran. Symptoms of depression and anxiety were evaluated using the Beck Depression and Anxiety Inventories. The mean WBC count increased with increasing severity of symptoms of depression and anxiety among men. Male participants with severe depression had significantly higher values of RDW (panxiety symptoms had significantly higher values of RDW (panxiety. Our results suggest that higher depression and anxiety scores are associated with an enhanced inflammatory state, as assessed by higher hematological inflammatory markers including WBC and RDW, even after adjusting for potential confounders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Haematological profile of cytomegalovirus antibody positive blood ...

    African Journals Online (AJOL)

    Screening forCMVantibodies was done using ELISA kit, manufactured by DIALAB, Austria. ( ). Complete blood count (PCV: Packed cell volume,WBC:White cell count-total and differential counts, and platelet counts) was done on all donors using automated coultermachine. Although the mean PCV value was higher in the ...

  1. Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity

    Directory of Open Access Journals (Sweden)

    Lell Bertrand

    2008-06-01

    Full Text Available Abstract Background Diligent and correct laboratory diagnosis and up-front identification of risk factors for progression to severe disease are the basis for optimal management of malaria. Methods Febrile children presenting to the Medical Research Unit at the Albert Schweitzer Hospital (HAS in Lambaréné, Gabon, were assessed for malaria. Giemsa-stained thick films for qualitative and quantitative diagnosis and enumeration of malaria pigment, or haemozoin (Hz-containing leukocytes (PCL were performed, and full blood counts (FBC were generated with a Cell Dyn 3000® instrument. Results Compared to standard light microscopy of Giemsa-stained thick films, diagnosis by platelet count only, by malaria pigment-containing monocytes (PCM only, or by pigment-containing granulocytes (PCN only yielded sensitivities/specificities of 92%/93%; 96%/96%; and 85%/96%, respectively. The platelet count was significantly lower in children with malaria compared to those without (p ® instrument detected significantly more patients with PCL (p Conclusion In the age group examined in the Lambaréné area, platelets are an excellent adjuvant tool to diagnose malaria. Pigment-containing leukocytes (PCL are more readily detected by automated scatter flow cytometry than by microscopy. Automated Hz detection by an instrument as used here is a reliable diagnostic tool and correlates with disease severity. However, clinical usefulness as a prognostic tool is limited due to an overlap of PCL numbers recorded in severe versus non-severe malaria. However, this is possibly because of the instrument detection algorithm was not geared towards this task, and data lost during processing; and thus adjusting the instrument's algorithm may allow to establish a meaningful cut-off value.

  2. Blood conservation with membrane oxygenators and dipyridamole.

    Science.gov (United States)

    Teoh, K H; Christakis, G T; Weisel, R D; Madonik, M M; Ivanov, J; Wong, P Y; Mee, A V; Levitt, D; Benak, A; Reilly, P

    1987-07-01

    Cardiopulmonary bypass induces platelet activation and dysfunction, which result in platelet deposition and depletion. Reduced platelet numbers and abnormal platelet function may contribute to postoperative bleeding. A membrane oxygenator may preserve platelets and reduce bleeding more than a bubble oxygenator, and the antiplatelet agent dipyridamole may protect platelets intraoperatively and reduce bleeding postoperatively. A prospective randomized trial was performed in 44 patients undergoing elective coronary artery bypass grafting to assess the effects of the membrane oxygenator and dipyridamole on platelet counts, platelet activation products, and postoperative bleeding. Patients who were randomized to receive a bubble oxygenator and no dipyridamole had the lowest postoperative platelet counts, the greatest blood loss, and the most blood products transfused. Platelet counts were highest and blood loss was least in patients randomized to receive a membrane oxygenator and dipyridamole (p less than .05). A bubble oxygenator with dipyridamole and a membrane oxygenator without dipyridamole resulted in intermediate postoperative platelet counts and blood loss. Arterial thromboxane B2 and platelet factor 4 concentrations were elevated on cardiopulmonary bypass in all groups. Both the membrane oxygenator and dipyridamole were independently effective (by multivariate analysis) in preserving platelets. Optimal blood conservation was achieved with a membrane oxygenator and dipyridamole.

  3. Establishment of reference values for complete blood count and blood gases in cynomolgus monkeys (Macaca fascicularis)

    Science.gov (United States)

    NAKAYAMA, Shunya; KOIE, Hiroshi; KANAYAMA, Kiichi; KATAKAI, Yuko; ITO-FUJISHIRO, Yasuyo; SANKAI, Tadashi; YASUTOMI, Yasuhiro; AGEYAMA, Naohide

    2017-01-01

    Cynomolgus monkeys are closely related to humans phylogenetically, and this has resulted in their widespread use as a preclinical model. Hematological data with regard to these monkeys are thus important. Although reference values for blood components and sex hormones have been established for cynomolgus monkeys, those for arterial blood gases have not. The arterial blood gases quickly reflect respiratory and circulatory dynamics, and are thus useful for animal management and safe general anesthesia and surgical operations. Furthermore, since O2 is transported by RBC, CBC and blood gases are closely related. The present study aimed to establish reference values for arterial blood gases and CBC in cynomolgus monkeys over a wide age range. Blood gases and CBC of arterial blood, collected from 41 female and 21 male anesthetized monkeys, were measured. Age correlated with RBC, HGB and HCT in the CBC. Values differed significantly between males and females in pCO2, CO2 concentration, MCV and MCH. The pH of blood was equivalent to that of humans and pCO2 was more stable, whereas MCV and MCH were lower than those in humans. Erythrocytes were smaller and less pigmented than in other Macaca species. Several relationships between gender and age, and blood gases and CBC were identified in cynomolgus monkeys. In conclusion, these reference values will be useful as markers for veterinary applications and in the care and maintenance of these animals. PMID:28381665

  4. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  5. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome

    Directory of Open Access Journals (Sweden)

    Younghak Lee

    2017-09-01

    Full Text Available BackgroundCushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined.MethodsA retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records.ResultsEosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome.ConclusionSmaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome.

  6. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome.

    Science.gov (United States)

    Lee, Younghak; Yi, Hyon Seung; Kim, Hae Ri; Joung, Kyong Hye; Kang, Yea Eun; Lee, Ju Hee; Kim, Koon Soon; Kim, Hyun Jin; Ku, Bon Jeong; Shong, Minho

    2017-09-01

    Cushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined. A retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records. Eosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome. Smaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome. Copyright © 2017 Korean Endocrine Society

  7. Enumeration of CD4+ T-cells using a portable microchip count platform in Tanzanian HIV-infected patients.

    Directory of Open Access Journals (Sweden)

    SangJun Moon

    Full Text Available CD4(+ T-lymphocyte count (CD4 count is a standard method used to monitor HIV-infected patients during anti-retroviral therapy (ART. The World Health Organization (WHO has pointed out or recommended that a handheld, point-of-care, reliable, and affordable CD4 count platform is urgently needed in resource-scarce settings.HIV-infected patient blood samples were tested at the point-of-care using a portable and label-free microchip CD4 count platform that we have developed. A total of 130 HIV-infected patient samples were collected that included 16 de-identified left over blood samples from Brigham and Women's Hospital (BWH, and 114 left over samples from Muhimbili University of Health and Allied Sciences (MUHAS enrolled in the HIV and AIDS care and treatment centers in the City of Dar es Salaam, Tanzania. The two data groups from BWH and MUHAS were analyzed and compared to the commonly accepted CD4 count reference method (FACSCalibur system.The portable, battery operated and microscope-free microchip platform developed in our laboratory (BWH showed significant correlation in CD4 counts compared with FACSCalibur system both at BWH (r = 0.94, p<0.01 and MUHAS (r = 0.49, p<0.01, which was supported by the Bland-Altman methods comparison analysis. The device rapidly produced CD4 count within 10 minutes using an in-house developed automated cell counting program.We obtained CD4 counts of HIV-infected patients using a portable platform which is an inexpensive (<$1 material cost and disposable microchip that uses whole blood sample (<10 µl without any pre-processing. The system operates without the need for antibody-based fluorescent labeling and expensive fluorescent illumination and microscope setup. This portable CD4 count platform displays agreement with the FACSCalibur results and has the potential to expand access to HIV and AIDS monitoring using fingerprick volume of whole blood and helping people who suffer from HIV and AIDS in resource

  8. Validation of an automated colony counting system for group A Streptococcus.

    Science.gov (United States)

    Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R

    2016-02-08

    The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth

  9. High white blood cell count at diagnosis of childhood acute lymphoblastic leukaemia: biological background and prognostic impact. Results from the NOPHO ALL-92 and ALL-2000 studies

    DEFF Research Database (Denmark)

    Vaitkeviciene, G; Forestier, E; Hellebostad, M

    2011-01-01

    Prognostic impact of peripheral blood white blood cell count (WBC) at the diagnosis of childhood acute lymphoblastic leukaemia (ALL) was evaluated in a population-based consecutive series of 2666 children aged 1–15 treated for ALL between 1992 and 2008 in the five Nordic countries (Denmark, Finland.......58) and for T-ALL (pEFS5y 0.71 vs. 0.38). Whether the inferior EFS for the subset of patients with high WBC and slow initial response to treatment reflects rare or overlooked cytogenetic aberrations as well as the factors that determine WBC levels at diagnosis awaits exploration....

  10. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods.

    Science.gov (United States)

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-03-01

    Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

  11. CELL RESPIRATION STUDIES : II. A COMPARATIVE STUDY OF THE OXYGEN CONSUMPTION OF BLOOD FROM NORMAL INDIVIDUALS AND PATIENTS WITH INCREASED LEUCOCYTE COUNTS (SEPSIS; CHRONIC MYELOGENOUS LEUCEMIA).

    Science.gov (United States)

    Daland, G A; Isaacs, R

    1927-06-30

    1. The oxygen consumption of blood of normal individuals, when the hemoglobin is saturated with oxygen, is practically zero within the limits of experimental error of the microspirometer used. 2. The oxygen consumed in a microspirometer by the blood of patients with chronic myelogenous leucemia with a high white blood cell count, and of one with leucocytosis from sepsis, was proportional to the number of adult polymorphonuclear neutrophils in the blood. 3. No correlation could be made between the rate of oxygen absorption and the total number of white blood cells in the blood, or the total number of immature cells, or the number of red blood cells, or the amount of oxyhemoglobin. 4. The blood of patients with chronic myelogenous leucemia continued to use oxygen in the microspirometer longer than that of normal individuals, and the hemoglobin, in the leucemic bloods, became desaturated even though exposed to air. 5. In blood in which the bulk. of the cells were immature and the mature cells few, the oxygen consumption was lower than in blood in which the mature cells predominated. The rate of oxygen consumption of the immature cells was relatively low as compared to the mature. 6. The slower rate of oxygen absorption by the immature leucocytes in chronic myelogenous leucemia as compared to the mature cells, places them, in accord with Warburg's reports, in the class of the malignant tissues in this respect rather than in the group of young or embryonic cells.

  12. [Effects of HiLo for two weeks on erythrocyte immune adhesion and leukocyte count of swimmers].

    Science.gov (United States)

    Zhao, Yong-Cai; Gao, Bing-Hong; Wu, Ge-Lin; Zhang, Jiu-Li

    2012-07-01

    To investigate the effects of living high-training low (HiLo) on innate immunity in blood of elite swimmers. Six female swimmers undertook HiLo for two weeks, erythrocyte adhesion function and counts of leukocyte were tested in different time of training period. Red blood cell C3b receptor ring rate (RBC-C3bRR) decreased and red blood cell immune complex matter ring rate (RBC-ICR) increased significantly (P < 0.05), the two markers returned to base line 1 week after training. Counts of leukocyte and granulocyte decreased significantly (P < 0.05), and they recovered 1 week after training; Counts of lymphocyte and monocyte decreased without significance during training and did not recovered after training. Immunity of erythrocyte and granulocyte decreased quickly, but lymphocyte and monocyte recovered slowly, swimmers were adaptive to the training.

  13. The role of donor characteristics and post-granulocyte colony-stimulating factor white blood cell counts in predicting the adverse events and yields of stem cell mobilization.

    Science.gov (United States)

    Chen, Shu-Huey; Yang, Shang-Hsien; Chu, Sung-Chao; Su, Yu-Chieh; Chang, Chu-Yu; Chiu, Ya-Wen; Kao, Ruey-Ho; Li, Dian-Kun; Yang, Kuo-Liang; Wang, Tso-Fu

    2011-05-01

    Granulocyte colony-stimulating factor (G-CSF) is now widely used for stem cell mobilization. We evaluated the role of post-G-CSF white blood cell (WBC) counts and donor factors in predicting adverse events and yields associated with mobilization. WBC counts were determined at baseline, after the third and the fifth dose of G-CSF in 476 healthy donors. Donors with WBC ≥ 50 × 10(3)/μL post the third dose of G-CSF experienced more fatigue, myalgia/arthralgia, and chills, but final post-G-CSF CD34(+) cell counts were similar. Although the final CD34(+) cell count was higher in donors with WBC ≥ 50 × 10(3)/μL post the fifth G-CSF, the incidence of side effects was similar. Females more frequently experienced headache, nausea/anorexia, vomiting, fever, and lower final CD34(+) cell count than did males. Donors with body mass index (BMI) ≥ 25 showed higher incidences of sweat and insomnia as well as higher final CD34(+) cell counts. Donor receiving G-CSF ≥ 10 μg/kg tended to experience bone pain, headache and chills more frequently. Multivariate analysis indicated that female gender is an independent factor predictive of the occurrence of most side effects, except for ECOG > 1 and chills. Higher BMI was also an independent predictor for fatigue, myalgia/arthralgia, and sweat. Higher G-CSF dose was associated with bone pain, while the WBC count post the third G-CSF was associated with fatigue only. In addition, one donor in the study period did not complete the mobilization due to suspected anaphylactoid reaction. Observation for 1 h after the first injection of G-CSF is required to prevent complications from unpredictable side effects.

  14. Positive correlation between postoperative tumor recurrence and changes in circulating tumor cell counts in pulmonary venous blood (pvCTC) during surgical manipulation in non-small cell lung cancer.

    Science.gov (United States)

    Hashimoto, Masaki; Tanaka, Fumihiro; Yoneda, Kazue; Takuwa, Teruhisa; Matsumoto, Seiji; Okumura, Yoshitomo; Kondo, Nobuyuki; Tsujimura, Tohru; Nakano, Takashi; Hasegawa, Seiki

    2018-01-01

    In non-small cell lung cancer (NSCLC), circulating tumor cells (CTC) are shed and circulate to the peripheral blood through the pulmonary vein. Previously, CTC count in pulmonary venous blood (pvCTC) was shown to significantly increase after surgical manipulation. Therefore, we assessed the correlation between the changes in the pvCTC count (ΔpvCTC) and clinical outcomes. Consecutive patients with peripheral-type, NSCLC, who underwent lobectomy or bi-lobectomy through open thoracotomy, were enrolled prospectively. Before and after lobectomy, 2.5 mL of blood was drawn from the associated lobar pulmonary vein (PV), and was served for the quantitative evaluation of CTC using the CellSearch ® system. The cut-off point of ΔpvCTC was determined according to clinical outcomes and ΔpvCTC using receiver operation characteristic (ROC) curve. Then the correlation between ΔpvCTC and clinical outcomes was evaluated by Kaplan-Meier analyses and log-rank test. In addition, the correlation between ΔpvCTC and perioperative variables was assessed. A total of 30 patients were enrolled, tumor recurrence occurred in 11 patients over a median follow-up of 64.4 months. Of these, 7 patients had distant metastasis and 4 had local recurrence. The median ΔpvCTC was 49 cells/2.5 mL, and pvCTC-count was increased during surgical manipulation in 24 patients (80%). We divided patients into two groups based on ΔpvCTC with the cut-off value as 119 cells/2.5 mL according to ROC curve. Significant shorter time to distant metastasis (TDM) (P=0.0123) was observed in high ΔpvCTC group (ΔpvCTC ≥119 cells/2.5 mL) than low ΔpvCTC group (ΔpvCTC <119 cells/ 2.5mL). Neither disease-free survival (DFS) nor overall survival (OS) was significantly correlated with ΔpvCTC. Increasing pvCTC count during surgical manipulation was significantly correlated with postoperative distant metastasis in completely resected NSCLC patients. Significant shorter TDM was observed in patient with high ΔpvCTC group.

  15. Performance of a coincidence based blood activity monitor

    International Nuclear Information System (INIS)

    Moses, W.W.

    1989-12-01

    A new device has been constructed that measures the positron emitting radio-tracer concentration in arterial blood by extracting blood with a peristaltic pump, then measuring the activity concentration by detecting coincident pairs of 511 keV photons with a pair of heavy inorganic scintillators attached to photomultiplier tubes. The sensitivity of this device is experimentally determined to be 610 counts/second per μCi/ml, and has a paralyzing dead time of 1.2 μs, so is capable of measuring blood activity concentration as high as 1 mCi/ml. Its performance is compared to two other blood monitoring methods: discrete blood samples counted with a well counter and device that uses a plastic scintillator to directly detect positrons. The positron detection efficiency of this device for 18 F is greater than the plastic scintillation counter, and also eliminates the radioisotope dependent correction factors necessary to convert count rate to absolute concentration. Coincident photon detection also has the potential of reducing the background compared to direct positron detection, thereby increasing the minimum detectable isotope concentration. 10 refs., 6 figs

  16. Effect of anabolic steroid on the recovery of white blood cell count after irradiation

    International Nuclear Information System (INIS)

    Yamagishi, Motohisa; Niki, Takamichi; Hiraoka, Atsunobu; Uchino, Haruto

    1979-01-01

    In order to observe the effects of nandrolone decanoate (NAN-D), an anabolic steroid, on granulocytes, its effect on the recovery of white blood cells (WBC) and granulocytes after radiation injuries was studied. Male mice were irradiated with 405 to 410 R of γ rays, and a 2.5 mg/dose of NAN-D was given subcutaneously 6 to 7 days after irradiation (group I) or immediately after irradiation (group II). The degree of decrease in WBC after irradiation was the same in both groups, but the recovery of WBC 18 days after irradiation was marked in group II, the control group, and group I, respectively. The recovery of granulocytes was the most marked in group II and was more marked in group I than in the control group. In an experiment in which NAN-D was given 2 to 3 days before irradiation (group III), WBC showed higher values in group III than in the control group 9 days after irradiation. The difference in WBC between group III and the control group was the greatest 17 days after irradiation. A gross count of granulocyte precursor cells in one femur clearly increased in the groups given this agent. (Tsunoda, M.)

  17. Agreement of manual cell counts and automated counts of the scil Vet abc Plus(+) hematology analyzer for analysis of equine synovial fluid.

    Science.gov (United States)

    Van de Water, Eline; Oosterlinck, Maarten; Duchateau, Luc; Pille, Frederik

    2016-06-01

    The purpose of this study was to determine whether the scil Vet abc Plus(+) (SCIL Animal Care Company, Altorf, France), an impedance hematology analyzer, can accurately quantify and differentiate nucleated blood cells (NBCs) in equine synovial fluid. Synovial fluid samples (n=242) in different stages of experimentally induced inflammation were analyzed with and without hyaluronidase pretreatment and compared to manual hemocytometer counts and smear reviews. No significant effect of hyaluronidase pretreatment was observed. Total nucleated cell counts of the scil Vet abc Plus(+) were significantly higher compared to the manual method (P=0.02), yet the difference was small and clinically irrelevant (ratio manual/automated count equal to 0.97 with 95% CI [0.95, 1.00]). Differential cell counts of the scil Vet abc Plus(+) were not accurate. In conclusion, the scil Vet abc Plus(+) hematology analyzer is highly accurate for quantification, but not accurate for differentiation of NBCs in equine synovial fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Radiological features of pulmonary tuberculosis in human immunodeficiency virus-infected patients: correlation with the blood CD4 cell count; Patrones radiologicos de la tuberculosis pulmonar en pacientes con infeccion VIH: correlacion con el indice de linfocitos CD4 en sangre

    Energy Technology Data Exchange (ETDEWEB)

    Isusi, M.; Eguidazu, J.; Oleaga, L.; Grande, D. [Hospital de Basurto. Bilbao (Spain)

    2000-07-01

    To describe the radiological features of pulmonary tuberculosis (TB) in patients infected with human immunodeficiency virus (HIV) and its correlation with the blood CD4 cell count. We present 44 HIV+patients, 24 with CD4 cell counts of less than 200 cells/mm''3 (group A) and 20 in whom the CD4 counts surpassed this level (group B). We also assessed the chest x-ray images to determine whether or not there was any correlation with the blood CD4 cell counts. Fisher's exact test was used for the statistical study of the differences in the radiological findings in the two groups. The incidence of atypical features was significantly greater in the patients with CD4 cell counts of less than 200 cells/mm''3 (group A) than in those with CD4 counts of over 200 cells/mm''3 (group B). Among HIV+patients, those with a more intact immune status were more likely to present lung x-ray images typical of post-primary TB, with cavitary lesions in upper lobes. The group of patients in whom the immune deficiency was more marked showed a greater incidence of atypical pulmonary findings, more characteristics of primary TB. (Author)

  19. Association of BPD and IVH with early neutrophil and white counts in VLBW neonates with gestational age <32 weeks

    Science.gov (United States)

    Palta, Mari; Sadek-Badawi, Mona; Carlton, David P

    2008-01-01

    Objectives To investigate associations between early low neutrophil count from routine blood samples, white blood count (WBC), pregnancy complications and neonatal outcomes for very low birth weight infants (VLBW ≤1500g) with gestational age <32 weeks. Patients and Methods Information was abstracted on all infants admitted to level III NICUs in Wisconsin 2003-2004. 1002 (78%) had differential and corrected total white counts within 2 ½ hours of birth. Data analyses included frequency tables, binary logistic, ordinal logistc and ordinary regression. Results Low neutrophil count (<1000/μL) was strongly associated with low WBC, pregnancy complications and antenatal steroids. Low neutrophil count predicted bronchopulmonary dysplasia severity level (BPD) (OR: 1.7, 95% CI: 1.1-2.7) and intraventricular hemorrhage (IVH) grade (OR: 2.2, 95% CI: 1.3-3.8). Conclusions Early neutrophil counts may have multiple causes interfering with their routine use as an inflammatory marker. Nonetheless, low neutrophil count has consistent independent associations with outcomes. PMID:18563166

  20. Safety of growth factor administration for leukapheresis in those with WBC counts greater than 60,000/µl.

    Science.gov (United States)

    Chen, Weihong; Rizzieri, David; Drago, Susan

    2015-02-01

    Peripheral blood stem cell mobilization using growth factors is a common method of stem cell collection for transplantation, however, little is reported concerning safety of continued growth factor delivery in exceptional responders with very high white blood cell (WBC) counts in preparation for pheresis. We performed a retrospective study of the safety of growth factor delivery for leukapheresis in those with WBC counts greater than 60,000/µl. Allogeneic donors received 5 days of granulocyte colony-stimulating factor (G-CSF) at a daily dose of 10 or 16 µg/kg. Autologous donors received G-CSF 10 µg/kg/day +/- chemotherapy until peripheral blood CD34(+) count reached 10/µl. Granulocyte donors received 300 µg dose of G-CSF the day prior to donation. Out of 3,037 leukapheresis collections from 1998 to 2005, we identified 303 collections from 204 donors or patients who had a WBC > 60,000/µl. WBC counts were ≥100,000/µl in seven of these subjects. If inadequate stem cell dose was obtained with pheresis with WBC counts this high, patients had growth factor dosing decreased 50% but still received a dose till stem cell collection was completed. Of the 204 subjects, 122 were patients and 82 were donors. These 204 donors/patients had no serious adverse events reported other than the common reports of myalgia, bone pain, and headache associated with administration of growth factors. Pain levels ranged from mild to severe and usually were managed by over the counter analgesics. Continuing ½ the dose of neupogen to complete the pheresis process appears safe in subjects with very high white blood counts. © 2014 Wiley Periodicals, Inc.

  1. Point-of-care, portable microfluidic blood analyzer system

    Science.gov (United States)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  2. Variation in blood serum proteins and association with somatic cell count in dairy cattle from multi-breed herds.

    Science.gov (United States)

    Bobbo, T; Fiore, E; Gianesella, M; Morgante, M; Gallo, L; Ruegg, P L; Bittante, G; Cecchinato, A

    2017-12-01

    Blood serum proteins are significant indicators of animal health. Nevertheless, several factors should be considered to appropriately interpret their concentrations in blood. Therefore, the objectives of this study were (1) to assess the effect of herd productivity, breed, age and stage of lactation on serum proteins and (2) to investigate association between serum proteins and somatic cell count (SCC) in dairy cattle. Milk and blood samples were collected from 1508 cows of six different breeds (Holstein Friesian, Brown Swiss, Jersey, Simmental, Rendena and Alpine Grey) that were housed in 41 multi-breed herds. Milk samples were analyzed for composition and SCC, while blood samples were analyzed for serum proteins (i.e. total protein, albumin, globulin and albumin-to-globulin ratio (A : G)). Herds were classified as low or high production, according to the cow's average daily milk energy yield adjusted for breed, days in milk (DIM) and parity. Data were analyzed using a linear mixed model that included the fixed effects of DIM, parity, SCS, breed, herd productivity and the random effect of the Herd-test date within productivity level. Cows in high producing herds (characterized also by greater use of concentrates in the diet) had greater serum albumin concentrations. Breed differences were reported for all traits, highlighting a possible genetic mechanism. The specialized breed Jersey and the two dual-purpose local breeds (Alpine Grey and Rendena) had the lowest globulin concentration and greatest A : G. Changes in serum proteins were observed through lactation. Total protein reached the highest concentration during the 4th month of lactation. Blood albumin increased with DIM following a quadratic pattern, while globulin decreased linearly. As a consequence, A : G increased linearly during lactation. Older cows had greater total protein and globulin concentrations, while albumin concentration seemed to be not particularly affected by age. A linear relationship

  3. Blood Eosinophil and Basophil Values Before and After Surgery for Eosinophilic-type Sinonasal Polyps.

    Science.gov (United States)

    Brescia, Giuseppe; Parrino, Daniela; Zanotti, Claudia; Tealdo, Giulia; Barion, Umberto; Sfriso, Paolo; Marioni, Gino

    2018-01-01

    Background Blood eosinophil and basophil levels have recently been considered for the purpose of endotyping chronic rhinosinusitis with nasal polyps (CRSwNP). Histologically, eosinophilic-type CRSwNPs have been associated with high recurrence rates after treatment. Objective The present study was the first to compare blood eosinophil and basophil counts in eosinophilic-type CRSwNP patients before and after endoscopic sinus surgery. Methods The study concerned 79 consecutive patients with histologically confirmed eosinophilic-type CRSwNP treated with endoscopic sinus surgery. Results A significant drop in mean blood eosinophil counts and percentages occurred from before to after endoscopic sinus surgery in the cohort as a whole. Mean blood eosinophil counts and percentages were also reduced after surgery in the subcohorts of CRSwNP patients with (i) asthma, (ii) aspirin-exacerbated respiratory disease (AERD), and (iii) no allergy. Although blood eosinophil and basophil counts correlated directly before and after surgery, a statistical reduction in blood basophil counts and percentages after surgery emerged only in the subcohort of nonallergic CRSwNP patients. Conclusion Endoscopic sinus surgery can clear polyps, remove inflammatory tissue, and reduce inflammatory cytokine levels. Consistently with the biological mechanism described, endoscopic sinus surgery could coincide with a reduction in blood eosinophils in eosinophilic-type CRSwNP.

  4. Three-dimensional counting of morphologically normal human red blood cells via digital holographic microscopy

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Lee, Yeon H.

    2015-01-01

    Counting morphologically normal cells in human red blood cells (RBCs) is extremely beneficial in the health care field. We propose a three-dimensional (3-D) classification method of automatically determining the morphologically normal RBCs in the phase image of multiple human RBCs that are obtained by off-axis digital holographic microscopy (DHM). The RBC holograms are first recorded by DHM, and then the phase images of multiple RBCs are reconstructed by a computational numerical algorithm. To design the classifier, the three typical RBC shapes, which are stomatocyte, discocyte, and echinocyte, are used for training and testing. Nonmain or abnormal RBC shapes different from the three normal shapes are defined as the fourth category. Ten features, including projected surface area, average phase value, mean corpuscular hemoglobin, perimeter, mean corpuscular hemoglobin surface density, circularity, mean phase of center part, sphericity coefficient, elongation, and pallor, are extracted from each RBC after segmenting the reconstructed phase images by using a watershed transform algorithm. Moreover, four additional properties, such as projected surface area, perimeter, average phase value, and elongation, are measured from the inner part of each cell, which can give significant information beyond the previous 10 features for the separation of the RBC groups; these are verified in the experiment by the statistical method of Hotelling's T-square test. We also apply the principal component analysis algorithm to reduce the dimension number of variables and establish the Gaussian mixture densities using the projected data with the first eight principal components. Consequently, the Gaussian mixtures are used to design the discriminant functions based on Bayesian decision theory. To improve the performance of the Bayes classifier and the accuracy of estimation of its error rate, the leaving-one-out technique is applied. Experimental results show that the proposed method can

  5. The calorically restricted low-fat nutrient-dense diet in Biosphere 2 significantly lowers blood glucose, total leukocyte count, cholesterol, and blood pressure in humans.

    Science.gov (United States)

    Walford, R L; Harris, S B; Gunion, M W

    1992-12-01

    Biosphere 2 is a 3.15-acre space containing an ecosystem that is energetically open (sunlight, electric power, and heat) but materially closed, with air, water, and organic material being recycled. Since September 1991, eight subjects (four women and four men) have been sealed inside, living on food crops grown within. Their diet, low in calories (average, 1780 kcal/day; 1 kcal = 4.184 kJ), low in fat (10% of calories), and nutrient-dense, conforms to that which in numerous animal experiments has promoted health, retarded aging, and extended maximum life span. We report here medical data on the eight subjects, comparing preclosure data with data through 6 months of closure. Significant changes included: (i) weight, 74 to 62 kg (men) and 61 to 54 kg (women); (ii) mean systolic/diastolic blood pressure (eight subjects), 109/74 to 89/58 mmHg (1 mmHg = 133 Pa); (iii) total serum cholesterol, from 191 +/- 11 to 123 +/- 9 mg/dl (mean +/- SD; 36% mean reduction), and high density lipoprotein, from 62 +/- 8 to 38 +/- 5 (risk ratio unchanged); (iv) triglyceride, 139 to 96 mg/dl (men) and 78 to 114 mg/dl (women); (v) fasting glucose, 92 to 74 mg/dl; (vi) leukocyte count, 6.7 to 4.7 x 10(9) cells per liter. We conclude that drastic reductions in cholesterol and blood pressure may be instituted in normal individuals in Western countries by application of a carefully chosen diet and that a low-calorie nutrient-dense regime shows physiologic features in humans similar to those in other animal species.

  6. CD20 positivity and white blood cell count predict treatment outcomes in Philadelphia chromosome-negative acute lymphoblastic leukemia patients ineligible for pediatric-inspired chemotherapy.

    Science.gov (United States)

    Isshiki, Yusuke; Ohwada, Chikako; Sakaida, Emiko; Onoda, Masahiro; Aotsuka, Nobuyuki; Tanaka, Hiroaki; Fukazawa, Motoharu; Cho, Ryuko; Sugawara, Takeaki; Kawaguchi, Takeharu; Hara, Satoru; Yokota, Akira

    2017-11-01

    The efficacy of conventional chemotherapy and allogeneic hematopoietic stem cell transplantation (allo-HSCT) has been controversial as post-remission therapies for adult Philadelphia chromosome-negative acute lymphoblastic leukemia patients. We retrospectively analyzed 96 adolescent and adult cases of Philadelphia chromosome-negative acute lymphoblastic leukemia to evaluate whether allo-HSCT should be performed after first complete remission (1CR). In total, 34 patients received chemotherapy followed by allo-HSCT (HSCT group) and 62 received chemotherapy alone (chemotherapy group). No significant differences in the event-free survival (EFS) or overall survival were observed between the two groups. In the chemotherapy group, use of pediatric regimens was significantly associated with favorable EFS, while high white blood cell (WBC) count and CD20 positivity were associated with poor outcome. In patients who received pediatric regimens, subsequent allo-HSCT did not influence EFS. In patients who received conventional chemotherapy (adult regimen), subsequent allo-HSCT did not improve EFS. High WBC count and CD20 positivity were also significantly associated with poor EFS in patients who received adult regimens. Patients with low WBC count and absence of CD20 who received adult regimens did not benefit from allo-HSCT. Allo-HSCT may not be required in the pediatric regimen-eligible patients; however, pediatric regimen-ineligible patients with either CD20 positivity or high WBC count should receive allo-HSCT after achieving 1CR. This study was registered at http://www.umin.ac.jp/ctr/ as #C000016287. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. White blood cell subtypes and risk of type 2 diabetes.

    Science.gov (United States)

    Zhang, Hongmei; Yang, Zhen; Zhang, Weiwei; Niu, Yixin; Li, Xiaoyong; Qin, Li; Su, Qing

    2017-01-01

    It is reported that total white blood cell is associated with risk of diabetes mellitus. The present study is to investigate the relationship of white blood cell subsets with incidence of type 2 diabetes at baseline and 3year follow-up. We chose individuals without diabetes history as our study population; 8991 individuals were included at baseline. All of the participants underwent a 75-g OGTT at baseline. White blood cell count including all the subsets were measured along with all the other laboratory indices. The participants who were not diagnosed with type 2 diabetes according to the WHO 1999 diagnostic criteria underwent another 75-g OGTT at 3year follow-up. The total WBC count, neutrophil count, and lymphocyte count were significantly increased in subjects newly diagnosed with diabetes mellitus compared to non-DM subjects at baseline (all ptype 2 diabetes. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Basic characteristics of plasma rich in growth factors (PRGF): blood cell components and biological effects.

    Science.gov (United States)

    Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Kawase, Tomoyuki

    2016-11-01

    Platelet-rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers ( N  = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84-fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79- and 5.51-fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose-dependent stimulation of periosteal cell proliferation in vitro.

  9. Effect of Graded Levels of Soybean Hull on Blood, Carcass and ...

    African Journals Online (AJOL)

    Each treatment was replicated 3 times with 2 pigs per replicate placed on concrete-floored pens. ... Results showed that pigs fed the control diets had comparable (p>0.05) packed cell volume (PCV), hemoglobin concentration (Hb), red blood cell counts (RBC), white blood cell counts (WBC), mean corpuscular hemoglobin ...

  10. PERIPHERAL BLOOD FILM - A REVIEW FEATURE ARTICLES

    African Journals Online (AJOL)

    consent, blood sampling technique, transport to the laboratory and ... methanol or ethyl alcohol and stained with a. Rowmanosky ... blood count, erythrocyte sedimentation rate, red cell ... of the smear due to high humidity, uraemia, Malnutrition.

  11. Reference values for maternal total and differential leukocyte counts in different trimesters of pregnancy and the initial postpartum period in western Turkey.

    Science.gov (United States)

    Sanci, Muzaffer; Töz, Emrah; Ince, Onur; Özcan, Aykut; Polater, Kevser; Inan, Abdurrahman Hamdi; Beyan, Emrah; Akkaya, Emrah

    2017-07-01

    The aim of this study was to investigate alterations in the leukocyte and differential leukocyte counts in different trimesters of pregnancy and the initial postpartum period. The study population consisted of 40,325 pregnant women. A full blood count and automated differential leukocyte count were performed and all the haemogram results in the different trimesters of pregnancy were recorded. Percentiles were calculated using statistical software. A total of 82,786 complete blood count evaluations were performed in 40,325 subjects from the 6th to 41st week of pregnancy and in the initial postpartum period. The leukocyte counts increased from the 1st to the 3rd trimester and peaked in the initial postpartum period. Our reference values for the total and differential leukocyte counts may assist clinicians in distinguishing between leukocytosis and pathological elevation of the white blood cell count during pregnancy and the initial postpartum period. Impact statement Pregnancy requires profound adaptation by multiple systems to accommodate the demands of the developing foetus. Similar to all other systems, many haematological changes occur during pregnancy. Studies of normal variation in leukocyte counts were insufficient to distinguish normal from abnormal leukocyte counts during pregnancy and in the initial postpartum period, due to small numbers of patients and a lack of differential leukocyte counts. Without reference leukocyte levels, infections may be more difficult to assess during pregnancy and in the postpartum period. In this study, we report the 3rd, 5th, 10th, 50th, 95th and 99th percentile values for the total and differential leukocyte counts according to trimester in normal pregnancy and the initial postpartum period. Our reference values for the total and differential leukocyte counts in each trimester and the initial postpartum period may assist clinicians in distinguishing between normal leukocytosis and pathological elevation of the white blood

  12. The Radiation Effect on Peripheral Blood Cell

    International Nuclear Information System (INIS)

    Lee, Tae June; Kwon, Hyoung Cheol; Kim, Jung Soo; Im, Sun Kyun; Choi, Ki Chul

    1988-01-01

    To evaluate radiation effect on the hematopoietic system, we analyzed 44 patients who were treated with conventionally fractionated radiation therapy (RT) at Chonbuk National University Hospital. According to the treatment sites, we classified them into three groups: group I as head and neck, group II as thorax, and group III as pelvis. White blood cell, lymphocyte, platelet and hemoglobin were checked before and during RT The results were as follow; 1. White blood cell (WBC) and lymphocyte count were declined from the first week of RT to the third week, and then slightly recovered after the third or fourth week. There was prominent decrease in lymphocyte counts than WBC. 2. Platelet counts were declined until the second week of the RT, showed slight recovery at fourth week in all groups. Hemoglobin values were slightly decreased in the first week and then recovered the level of pretreatment value, gradually. 3. Lymphocyte count were declined significantly on group III(p<0.01), WBC and platelet counts were decreased on group II but statistically not significant

  13. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy

    Science.gov (United States)

    Enko, Dietmar; Mangge, Harald; Münch, Andreas; Niedrist, Tobias; Mahla, Elisabeth; Metzler, Helfried; Prüller, Florian

    2017-01-01

    Introduction The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods Venous blood was collected into six 4.5 mL VACUETTE® 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, Kremsmünster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ≤ 25%. Conclusions Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced. PMID:28392742

  14. Total lymphoid irradiation in multiple sclerosis: blood lymphocytes and clinical course

    International Nuclear Information System (INIS)

    Cook, S.D.; Devereux, C.; Troiano, R.; Zito, G.; Hafstein, M.; Lavenhar, M.; Hernandez, E.; Dowling, P.C.

    1987-01-01

    We have found a significant relationship between blood lymphocyte count and prognosis in 45 patients receiving either total lymphoid irradiation or sham irradiation for chronic progressive multiple sclerosis. Patients with sustained lymphocyte counts less than 900 mm-3 for prolonged periods after treatment showed less rapid progression over the ensuing 3 years than did patients with multiple sclerosis who had lymphocyte counts above this level (p less than 0.01). Our results suggest that a simple laboratory test, the absolute blood lymphocyte count, may serve as a valuable barometer for monitoring the amount of immunosuppressive therapy needed to prevent progression in patients with multiple sclerosis, and possibly other autoimmune diseases

  15. Effects of Some Plant Extracts in Triticale-Based Broiler Diets on Growth Performance, E.Coli Counts in Intestine and Blood Parameters

    Directory of Open Access Journals (Sweden)

    Ergun Demir

    2016-10-01

    Full Text Available This study was conducted to determine the effect of using plant essential oils in triticale-based broiler diets as alternative to antimicrobial growth promotors (AGPs on growth, E.coli counts in small intestine and blood parameters. 720 male broiler chicks were randomly distributed to nine experimental groups with four replicates. The control group received the triticale-soybean meal basal diet. In the other treatment groups the basal diet was supplemented with one of the following; flavomycin, enzyme, flavomycin+enzyme, enzyme+thyme oil, enzyme+fennel oil, enzyme+bay leaf oil, enzyme+thyme oil+fennel oil and enzyme+thyme oil+fennel oil+bay leaf oil. Results showed that the weight gain and feed intake were not influenced by the treatments (P>0,05. The use of the combination of plant extracts significantly improved the feed conversion. Use of plant extracts in triticale-based broiler diets as an alternative to AGPs had no regular effect on E.coli count in small intestine segments (P>0,05. Feeding broiler chickens with the enzyme+thyme oil supplemented diets increased eritrocyte level in serum (P0,05 by the treatments. In conclusion, these plant ectracts can be also used with enzyme in triticale-based broiler diets as alternative to AGPs.

  16. Association of the blood eosinophil count with hematological malignancies and mortality

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, Volkert Dirk; Hasselbalch, Hans K

    2015-01-01

    Blood eosinophilia (≥0.5 × 109/l) may be an early sign of hematological malignancy. We investigated associations between levels of blood eosinophils and risks of hematological malignancies and mortality in order to provide clinically derived cut-offs for referral to specialist hematology care. Fr...

  17. Flow rate calibration to determine cell-derived microparticles and homogeneity of blood components.

    Science.gov (United States)

    Noulsri, Egarit; Lerdwana, Surada; Kittisares, Kulvara; Palasuwan, Attakorn; Palasuwan, Duangdao

    2017-08-01

    Cell-derived microparticles (MPs) are currently of great interest to screening transfusion donors and blood components. However, the current approach to counting MPs is not affordable for routine laboratory use due to its high cost. The current study aimed to investigate the potential use of flow-rate calibration for counting MPs in whole blood, packed red blood cells (PRBCs), and platelet concentrates (PCs). The accuracy of flow-rate calibration was investigated by comparing the platelet counts of an automated counter and a flow-rate calibrator. The concentration of MPs and their origins in whole blood (n=100), PRBCs (n=100), and PCs (n=92) were determined using a FACSCalibur. The MPs' fold-changes were calculated to assess the homogeneity of the blood components. Comparing the platelet counts conducted by automated counting and flow-rate calibration showed an r 2 of 0.6 (y=0.69x+97,620). The CVs of the within-run and between-run variations of flow-rate calibration were 8.2% and 12.1%, respectively. The Bland-Altman plot showed a mean bias of -31,142platelets/μl. MP enumeration revealed both the difference in MP levels and their origins in whole blood, PRBCs, and PCs. Screening the blood components demonstrated high heterogeneity of the MP levels in PCs when compared to whole blood and PRBCs. The results of the present study suggest the accuracy and precision of flow-rate calibration for enumerating MPs. This flow-rate approach is affordable for assessing the homogeneity of MPs in blood components in routine laboratory practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Error in laboratory report data for platelet count assessment in patients suspicious for dengue: a note from observation

    Directory of Open Access Journals (Sweden)

    Somsri Wiwanitkit

    2016-08-01

    Full Text Available Dengue is a common tropical infection that is still a global health threat. An important laboratory parameter for the management of dengue is platelet count. Platelet count is an useful test for diagnosis and following up on dengue. However, errors in laboratory reports can occur. This study is a retrospective analysis on laboratory report data of complete blood count in cases with suspicious dengue in a medical center within 1 month period during the outbreak season on October, 2015. According to the studied period, there were 184 requests for complete blood count for cases suspected for dengue. From those 184 laboratory report records, errors can be seen in 12 reports (6.5%. This study demonstrates that there are considerable high rate of post-analytical errors in laboratory reports. Interestingly, the platelet count in those erroneous reports can be unreliable and ineffective or problematic when it is used for the management of dengue suspicious patients.

  19. Contribution of a portable air plasma torch to rapid blood coagulation as a method of preventing bleeding

    International Nuclear Information System (INIS)

    Kuo, S P; Chen, C Y; Fan, H W; Tarasenko, O; Scott, A; Lahiani, M; Alusta, P; Chang, J; Popovic, S; Drake, J D; Nikolic, M

    2009-01-01

    The effectiveness and mechanism of a low temperature air plasma torch in clotting blood are explored. Both blood droplets and smeared blood samples were used in the tests. The treated droplet samples reveal how blood clotting depends on the distance at which the torch operated, and for how long the droplets have been exposed to the torch. Microscopy and cell count of smeared blood samples shed light on dependencies of erythrocyte and platelet counts on torch distance and exposure time. With an increase of torch distance, the platelet count of treated blood samples increases but is less than that of the control. The flux of reactive atomic oxygen (RAO) and the degree of blood clotting decreased. With an increase of exposure time, platelet count of treated samples decreased, while the degree of clot increased. The correlation among these dependencies and published data support a blood clotting mechanism that RAO as well as other likely reactive oxygen species generated by the plasma torch activate erythrocyte-platelets interactions and induces blood coagulation.

  20. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination

    Directory of Open Access Journals (Sweden)

    Yutaka Kitamura

    2018-02-01

    Full Text Available Platelet-rich fibrin (PRF clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.

  1. Effects of Wine by-Products on Growth Performance, Complete Blood Count and Total Antioxidant Status in Broilers

    Directory of Open Access Journals (Sweden)

    SM Pascariu

    Full Text Available ABSTRACT This study aimed to investigate the effect of whole grape pomace (GP, grape seed (GS and grape pomace polyphenolic extract (GPEP on growth performance, total antioxidant status (TAS and complete blood count (CBC of 40-day-old chicks (hybrid Cobb 500. A total of 432 unsexed one-day-old chicks were divided into six groups: control (CON and five experimental groups, 10 g/kg GP, 20 g/kg GP, 5 g/kg GS, 10 g/kg GS and 15 mL/L GPEP. The results showed a higher increase in growing rate in 5 g/kg GS group, from the first week of the chicks’ life throughout their growth, the average body weight of the chicks being significantly higher (p0.05 at 40 days of age. As a conclusion, the amount of 5 g/kg seeds, 10 g/kg and 20 g/kg pomace, can be added to the diet of the broilers, the dose of 5 g/kg seeds in the diet offering advantages in growing rate and feed valorization in weight gain.

  2. Interpretation of serum antibody response to Anoplocephala perfoliata in relation to parasite burden and faecal egg count

    DEFF Research Database (Denmark)

    Kjaer, L.N.; Lungholt, M.M.; Nielsen, M.K.

    2007-01-01

    of development and gross pathological mucosal lesions were recorded and compared with serum antibody responses and faecal egg counts. Faecal egg counts were determined in samples from A. perfoliata infected horses using a semi-quantitative centrifugation/flotation technique. Blood samples collected at slaughter...

  3. Association of peripheral total and differential leukocyte counts with obesity-related complications in young adults.

    Science.gov (United States)

    Yoshimura, Aya; Ohnishi, Shunsuke; Orito, Chieko; Kawahara, Yukako; Takasaki, Hiroyo; Takeda, Hiroshi; Sakamoto, Naoya; Hashino, Satoshi

    2015-01-01

    Obesity has been demonstrated to be associated with elevated leukocytes in adults and children. This study assessed the associations between peripheral total and differential leukocyte counts and obesity-related complications in young adults. 12 obese (median age 21.5 (range 19-28) years, median BMI 35.7 (range 32.0-44.9) kg/m(2)) and 11 normal (median age 23 (range 18-27) years, median BMI 19.5 (range 18.1-21.7) kg/m(2)) adults were enrolled. Complete blood count and serum levels of liver enzymes, fasting blood glucose, insulin and lipids were measured, and the homeostasis model assessment of insulin resistance was calculated. Fat mass was calculated using a bioimpedance analysis device, and ultrasonography was performed to measure fat thickness and to detect fatty change of the liver. Total leukocyte and monocyte counts were significantly increased in obese young adults. Total leukocyte count was associated with liver enzyme levels, insulin resistance as well as visceral and subcutaneous fat thickness. Neutrophil count was associated with insulin resistance. Lymphocyte count was associated with serum liver enzymes, insulin resistance, and dyslipidemia. Monocyte count was associated with serum liver enzyme, insulin resistance, visceral and subcutaneous fat thickness, body fat mass, and percentage body fat. The results of this study suggest that chronic low-grade systemic inflammation is associated with obesity-related complications such as nonalcoholic fatty liver disease, insulin resistance, and dyslipidemia in young adults. © 2015 S. Karger GmbH, Freiburg.

  4. EVALUATION OF ZEBU NELLORE CATTLE BLOOD SAMPLES USING THE CELL-DYN 3500 HEMATOLOGY ANALYZER

    Directory of Open Access Journals (Sweden)

    Alexandre Secorun Borges

    2014-12-01

    Full Text Available The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Celldyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510 and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson’s correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semiautomated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

  5. An Evaluation of the Accuracy of the Subtraction Method Used for Determining Platelet Counts in Advanced Platelet-Rich Fibrin and Concentrated Growth Factor Preparations

    Directory of Open Access Journals (Sweden)

    Taisuke Watanabe

    2017-01-01

    Full Text Available Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF and concentrated growth factors (CGF according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately.

  6. Umbilical nucleated red blood cell as a sign of fetal distress

    Directory of Open Access Journals (Sweden)

    Torkestani F

    2008-06-01

    Full Text Available Background: The presence of increased numbers of nucleated red blood cell (NRBC in the umbilical cord blood has been associated with states of relative hypoxia. Nucleated red blood cell counts are a potentially useful tool in estimating the degree and timing of intrauterine hypoxia. This may have important implication in determining causality in case of compromised infant. Cord blood NRBC counts may be obtained noninvasively from an otherwise discarded specimen and analyzed by personnel on equipment readily available in most hospital laboratories. Since the aim of monitoring of fetal heart is early diagnosis of hypoxia, we studied the relationship between abnormal fetal heart rate with the number of nucleated red blood cells (NRBC in the umbilical cord blood.Methods: We performed this research at Hazrat Zeynab Hospital on 130 full-term newborns (65 cases of fetal distress and 65 normal cases between July 2005 and July 2006. The NRBC counts of newborns with abnormal fetal heart rate were compared with those of normal newborns and correlations with other parameters including Apgar score, hemoglobin level, condition of newborns in the first 24 hours of the birth and birth weight.Results: The mean NRBC count in the fetal distress group was 9.45 ± 8.75 and that of the normal group was 9.17 ± 8.76 per 100 white cells (p=0.89. The mean duration between diagnosis of fetal distress to birth was equal to 1.2± 0.77 hours. Furthermore, there was no meaningful correlation between number of NRBC and Apgar score, hemoglobin, birth weight and condition of newborns in the first 24 hours.Conclusion: If the fetus is born a short time after the diagnosis of distress with no risk factors for hypoxia, the NRBC count for cord blood is not elevated.

  7. Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport.

    Science.gov (United States)

    Cox, Holly D; Eichner, Daniel

    2017-09-19

    The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.

  8. Comparison of Hematologic and Biochemical Test Results in Blood Samples Obtained by Jugular Venipuncture Versus Nail Clip in Moluccan Cockatoos (Cacatua moluccensis).

    Science.gov (United States)

    Bennett, Tracy D; Lejnieks, Daniel V; Koepke, Hoyt; Grimson, Fiona; Szucs, Jennifer; Omaits, Kerri; Lane, Rosalie

    2015-12-01

    In birds, blood samples are often collected from the jugular, medial metatarsal, and basilic vein. Samples are sometimes collected by toe nail clip, but concerns to avoid drawing blood from the nail include pain after nail clips for blood collection, potential differences in complete blood count (CBC) results, and potential contamination with uric acid values. To compare differences in biochemical and hematologic values in blood samples obtained by jugular venipuncture versus toenail clip, blood samples were collected from Moluccan cockatoos (Cacatua moluccensis) (N = 23) and sent to a commercial laboratory for routine CBCs and serum biochemical analysis. Results showed good agreement between venipuncture and nail clip blood samples in red blood cell count, packed cell volume, heterophil count and percentage, lymphocyte count and percentage, aspartate aminotransferase, chloride, creatine phosphokinase, glucose, lactate dehydrogenase, total protein, and uric acid values. Constant bias was found in values of bile acids, cholesterol, and hemoglobin. Proportional bias toward higher values in the jugular sample were found in total white blood cell (WBC) count and inorganic phosphorus. Serum calcium plots revealed a proportional bias toward higher values in the toe nail blood when values were increased. Results suggest some differences in WBC count, bile acids, calcium, cholesterol, hemoglobin, and phosphorus values between blood samples collected by jugular venipuncture and samples collected by toe nail clip, but the differences are mostly minor and, with the possible exception of inorganic phosphorus and marginally elevated or very low WBC counts, are unlikely to affect the use or interpretation of the avian blood panel.

  9. The Effect of Cellphone Radiation on Hematological Blood Cell Factors In BALB/C Mice

    Directory of Open Access Journals (Sweden)

    Fatemeh Zakieh Tohidi

    2016-03-01

    Full Text Available Introduction The continuous and rapid growth of telecommunication industries, along with the common application of cell phones, hasraised debates on the associated risks for humanhealth due to exposure to radiofrequency fields, caused bycell phonesorother sources, and industrial and medical applications. Accordingly, in this study, we aimed to investigate the effects of cell phone radiation on BALB/c mice blood factors. Materials and Methods In this study, 48 BALB/c mice were divided into six groups, each consisting of eight animals. Fourexposure groups were exposed to radiation waves twice a day for 30 min, 1 h, 2 h, and 4 h, respectivelyover one month. On the other hand,one exposure group wasexposed to 900 and 1800 MHz radiations (2 Wfor 4 h once a day. Afterwards, the blood samples were taken from the heart, and blood factors including white blood cell count, red blood cell count, platelet count, hemoglobin level, hematocrit level, MCH, MCHC,neutrophil count, and lymphocyte count weremeasured and analyzed by SPSS version 15. Results Based on the findings, MCHC in the exposure groupreceiving 0.5 h of radiation and MCH in the exposure groupsreceiving 0.5, 2, and 4 h of radiationwere significantlydifferentfromthe control group (P

  10. Multiple loci are associated with white blood cell phenotypes.

    Directory of Open Access Journals (Sweden)

    Michael A Nalls

    2011-06-01

    Full Text Available White blood cell (WBC count is a common clinical measure from complete blood count assays, and it varies widely among healthy individuals. Total WBC count and its constituent subtypes have been shown to be moderately heritable, with the heritability estimates varying across cell types. We studied 19,509 subjects from seven cohorts in a discovery analysis, and 11,823 subjects from ten cohorts for replication analyses, to determine genetic factors influencing variability within the normal hematological range for total WBC count and five WBC subtype measures. Cohort specific data was supplied by the CHARGE, HeamGen, and INGI consortia, as well as independent collaborative studies. We identified and replicated ten associations with total WBC count and five WBC subtypes at seven different genomic loci (total WBC count-6p21 in the HLA region, 17q21 near ORMDL3, and CSF3; neutrophil count-17q21; basophil count- 3p21 near RPN1 and C3orf27; lymphocyte count-6p21, 19p13 at EPS15L1; monocyte count-2q31 at ITGA4, 3q21, 8q24 an intergenic region, 9q31 near EDG2, including three previously reported associations and seven novel associations. To investigate functional relationships among variants contributing to variability in the six WBC traits, we utilized gene expression- and pathways-based analyses. We implemented gene-clustering algorithms to evaluate functional connectivity among implicated loci and showed functional relationships across cell types. Gene expression data from whole blood was utilized to show that significant biological consequences can be extracted from our genome-wide analyses, with effect estimates for significant loci from the meta-analyses being highly corellated with the proximal gene expression. In addition, collaborative efforts between the groups contributing to this study and related studies conducted by the COGENT and RIKEN groups allowed for the examination of effect homogeneity for genome-wide significant associations across

  11. Use of the lymphocyte count as a diagnostic screen in adults with suspected Epstein-Barr virus infectious mononucleosis.

    Science.gov (United States)

    Biggs, Timothy C; Hayes, Stephen M; Bird, Jonathan H; Harries, Philip G; Salib, Rami J

    2013-10-01

    To evaluate the predictive diagnostic accuracy of the lymphocyte count in Epstein-Barr virus-related infectious mononucleosis (IM). Retrospective case note and blood results review within a university-affiliated teaching hospital. A retrospective review of 726 patients undergoing full blood count and Monospot testing was undertaken. Monospot testing outcomes were compared with the lymphocyte count, examining for significant statistical correlations. With a lymphocyte count of ≤4 × 10(9) /L, 99% of patients had an associated negative Monospot result (sensitivity of 84% and specificity of 94%). A group subanalysis of the population older than 18 years with a lymphocyte count ≤4 × 10(9) /L revealed that 100% were Monospot negative (sensitivity of 100% and specificity of 97%). A lymphocyte count of ≤4 × 10(9) /L correlated significantly with a negative Monospot result. A lymphocyte count of ≤4 × 10(9) /L appears to be a highly reliable predictor of a negative Monospot result, particularly in the population aged >18 years. Pediatric patients, and adults with strongly suggestive symptoms and signs of IM, should still undergo Monospot testing. However, in adults with more subtle symptoms and signs, representing the vast majority, Monospot testing should be restricted to those with a lymphocyte count >4 × 10(9) /L. NA Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  12. A gravimetric simplified method for nucleated marrow cell counting using an injection needle.

    Science.gov (United States)

    Saitoh, Toshiki; Fang, Liu; Matsumoto, Kiyoshi

    2005-08-01

    A simplified gravimetric marrow cell counting method for rats is proposed for a regular screening method. After fresh bone marrow was aspirated by an injection needle, the marrow cells were suspended in carbonate buffered saline. The nucleated marrow cell count (NMC) was measured by an automated multi-blood cell analyzer. When this gravimetric method was applied to rats, the NMC of the left and right femurs had essentially identical values due to careful handling. The NMC at 4 to 10 weeks of age in male and female Crj:CD(SD)IGS rats was 2.72 to 1.96 and 2.75 to 1.98 (x10(6) counts/mg), respectively. More useful information for evaluation could be obtained by using this gravimetric method in addition to myelogram examination. However, some difficulties with this method include low NMC due to blood contamination and variation of NMC due to handling. Therefore, the utility of this gravimetric method for screening will be clarified by the accumulation of the data on myelotoxicity studies with this method.

  13. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.

    Science.gov (United States)

    Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A

    2018-02-01

    Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.

  14. Analyses of cardiac blood cells and serum proteins with regard to cause of death in forensic autopsy cases.

    Science.gov (United States)

    Quan, Li; Ishikawa, Takaki; Michiue, Tomomi; Li, Dong-Ri; Zhao, Dong; Yoshida, Chiemi; Chen, Jian-Hua; Komatsu, Ayumi; Azuma, Yoko; Sakoda, Shigeki; Zhu, Bao-Li; Maeda, Hitoshi

    2009-04-01

    To investigate hematological and serum protein profiles of cadaveric heart blood with regard to the cause of death, serial forensic autopsy cases (n=308, >18 years of age, within 48 h postmortem) were examined. Red blood cells (Rbc), hemoglobin (Hb), platelets (Plt), white blood cells (Wbc), total protein (TP) and albumin (Alb) were examined in bilateral cardiac blood. Blood cell counts, collected after turning the bodies at autopsy, approximated to the clinical values. Postmortem changes were not significant for these markers. In non-head blunt injury cases, Rbc counts, Hb, TP and Alb levels in bilateral cardiac blood were lower in subacute deaths (survival time, 1-12 h) than in acute deaths (survival time hematology analyzer than by using a blood smear test, suggesting Rbc fragmentation caused by deep burns, while increases in Wbc count and decreases in Alb levels were seen for subacute deaths. For asphyxiation, Rbc count, Hb, TP and Alb levels in bilateral cardiac blood were higher than other groups, and TP and Alb levels in the right cardiac blood were higher for hanging than for strangulation. These findings suggest that analyses of blood cells and proteins are useful for investigating the cause of death.

  15. [South American camelids in Switzerland. II. Reference values for blood parameters].

    Science.gov (United States)

    Hengrave Burri, I; Tschudi, P; Martig, J; Liesegang, A; Meylan, M

    2005-08-01

    In order to establish reference values for blood parameters of South American camelids in Switzerland, 273 blood samples were collected from 141 llamas and 132 alpacas. These animals were classified in three categories (young animals blood cell count, white blood cell count, electrolytes, metabolites and enzymes). Significant differences between llamas and alpacas were evident for 26 parameters. This study also showed that differences between young animals, females and males must be taken into consideration. A comparison of blood values with the results of fecal analysis for parasite eggs showed that an infestation with Dicrocoelium dendriticum was associated with elevated activity of two liver enzymes (GLDH and gamma-GT) in the serum. In contrast, no differences were found in the results of blood analyses between animals shedding eggs of gastrointestinal strongyles or not.

  16. A Survey of Blood Request Versus Blood Utilization at a University Hospital in Iran

    Directory of Open Access Journals (Sweden)

    Arash Peivandi Yazdi

    2016-01-01

    Full Text Available Background: Reservation of blood leads to blood wastage if the blood is not transfused. Therefore, in some centers only blood type and screen are evaluated. In this study, the efficacy of a blood crossmatch-to-transfusion ratio was measured and then compared with the standard levels. Methods: This prospective study was conducted during one year in a university hospital. During this period, 398 patients for whom blood had been requested were studied. In these patients, at the first surgical type, the laboratory tests (hematocrit, hemoglobin, platelet count, and prothrombin time and the number of preoperative crossmatched and intraoperative transfused blood units were recorded. Then the crossmatch-to-transfusion ratio, transfusion probability, transfusion index, and correlation between related factors, and the transfusion ratio were evaluated. Results: In this cross-sectional study, blood was requested for 398 patients. According to available blood unit deficiency, from 961 blood unit requisitions, only 456 units were crossmatched and 123 units were transfused. The crossmatch-to-transfusion ratio, transfusion probability, and transfusion index were 3.71 (7.81 if all requisitions were crossmatched, 16.83%, and 0.31, respectively. The most unfavorable indexes were observed in patients who had ear, nose, and throat surgeries (0 transfused from 19 crossmatched blood units and obstetric and gynecologic surgery (crossmatch-to-transfusion ratio was 18.6. The best indexes were related to thoracic surgery and neurosurgery (crossmatch-to-transfusion ratio was 1.53 and 1.54, respectively. There were no significant correlations between hemoglobin, hematocrit, platelet count, and prothrombin time with the number of transfused blood units (P = 0.2, 0.14, 0.26, and 0.06, respectively. Conclusion: The data for the crossmatch-to-transfusion ratio, transfusion probability, and transfusion index were suboptimal at this center, especially for ear, nose, and throat

  17. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  18. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  19. Evaluation of the impact of banking umbilical cord blood units with high cell dose for ethnically diverse patients.

    Science.gov (United States)

    Stritesky, Gretta; Wadsworth, Kimberly; Duffy, Merry; Buck, Kelly; Dehn, Jason

    2018-02-01

    Umbilical cord blood units provide an important stem cell source for transplantation, particularly for patients of ethnic diversity who may not have suitably matched available, adult-unrelated donors. However, with the cost of cord blood unit acquisition from public banks significantly higher than that for adult-unrelated donors, attention is focused on decreasing cost yet still providing cord blood units to patients in need. Historical practices of banking units with low total nucleated cell counts, including units with approximately 90 × 10 7 total nucleated cells, indicates that most banked cord blood units have much lower total nucleated cell counts than are required for transplant. The objective of this study was to determine the impact on the ability to identify suitable cord blood units for transplantation if the minimum total nucleated cell count for banking were increased from 90 × 10 7 to 124 or 149 × 10 7 . We analyzed ethnically diverse patients (median age, 3 years) who underwent transplantation of a single cord blood unit in 2005 to 2016. A cord blood unit search was evaluated to identify units with equal or greater human leukocyte antigen matching and a greater total nucleated cell count than that of the transplanted cord blood unit (the replacement cord blood unit). If the minimum total nucleated cell count for banking increased to 124 or 149 × 10 7 , then from 75 to 80% of patients would still have at least 1 replacement cord blood unit in the current (2016) cord blood unit inventory. The best replacement cord blood units were often found among cords with the same ethnic background as the patient. The current data suggest that, if the minimum total nucleated cell count were increased for banking, then it would likely lead to an inventory of more desirable cord blood units while having minimal impact on the identification of suitable cord blood units for transplantation. © 2017 AABB.

  20. Skin tags: A link between lesional mast cell count/tryptase expression and obesity and dyslipidemia

    Directory of Open Access Journals (Sweden)

    Samar Abdallah M Salem

    2013-01-01

    Full Text Available Background:The etiology of skin tags (STs is not fully understood. A relation to diabetes mellitus and obesity was suggested. Few studies of possible mast cells (MCs involvement were reported. Tyrptase is a mast cell mediator and a potent fibroblast growth factor. It may provide a molecular link between mast cell activation and fibrosis. Aims: The aim was to assess clinical and laboratory findings in patients with STs, and the possible link between obesity, dyslipidemia, and lesional MC count/tryptase expression. Materials and Methods: A total of 20 patients with STs were subjected to clinical examination, estimation of body mass index (BMI, fasting blood glucose (FBG, postprandial blood glucose (PPBG, serum cholesterol and triglycerides, abdominal ultrasound for fatty liver assessment, in addition to study of MCs through staining for MC tryptase in two skin biopsies; lesional and nonlesional (control. Results:All patients showed abnormally high BMI and hypertriglyceridemia, with abnormal sonographic pattern in 15 patients (75%. STs number positively correlated with the age of patients. STs showed significantly higher MC counts and tryptase expression, compared with control skin ( P < 0.001, with no correlation of the STs number or MC count with BMI, FBG, PPBG or serum cholesterol. Obese patients showed a significantly higher MC count than overweight and there was a positive correlation between MC count and serum triglycerides. Axilla and under breast STs showed a higher MC count compared with other sites. Conclusions:STs seem to be related to obesity and hypertriglyceridemia. MCs with their tryptase are possibly involved in pathogenesis of STs. MC count is related to the associated factors; obesity and serum triglycerides. MC tryptase expression is a reliable method for accurate tissue MC counting.

  1. Investigation of venous blood cells parameters among 1180 healthy people in Tianjin area

    International Nuclear Information System (INIS)

    Jiang Liping; Hao Jianxiu; Li Jin; Xing Zhiwei; Zhao Xinran; Jiang Bo; Wang Xiaoguang; Jiang Enhai

    2013-01-01

    Objective: To investigate the reference values of 18 parameters of venous blood cells among healthy adults in Tianjin area. Methods: The values of 18 parameters of venous blood from 1180 healthy adults in Tianjin area were measured by Sysmex KX-21 hematology analyzer and the results were analyzed. Results: The statistical analysis of the test reveals that significant differences exist in most parameters of venous blood cells according to the gender and age of people. Except the parameters of mean corpuscular volume, lymphocytes percentage, mean platelet volume, platelet distribution width,there were significant differences in the remaining parameters between the males group and the females group. Except the parameters of white blood count,platelet count, mean corpuscular hemoglobin, neutrophil percentage,absolute neutrophil count, mean platelet volume, platelet distribution width, there were significant differences in the remaining parameters between the old male group and the adult male group. Except the parameters of white blood count, mean corpuscular volume, mean corpuscular hemoglobin, there was no significant difference in the remaining parameters between the old female group and the adult female group. Conclusions: There are some differences between the findings and the reference range provided by the National Guide to Clinical laboratory Procedure. Therefore, it is necessary for laboratory to establish the reference values of venous blood cells according to concrete conditions. (authors)

  2. The influence of time in captivity, food intake and acute trauma on blood analytes of juvenile Steller sea lions, Eumetopias jubatus

    Science.gov (United States)

    Skinner, John P.; Tuomi, Pam A.; Mellish, Jo-Ann E.

    2015-01-01

    The Steller sea lion, Eumetopias jubatus, has experienced regionally divergent population trends over recent decades. One potential mechanism for this disparity is that local factors cause reduced health and, therefore, reduced survival of individuals. The use of blood parameters to assess sea lion health may help to identify whether malnutrition, disease and stress are important drivers of current trends, but such assessments require species-specific knowledge of how parameters respond to various health challenges. We used principal components analysis to identify which key blood parameters (principal analytes) best described changes in health for temporarily captive juvenile Steller sea lions in known conditions. Generalized additive mixed models were used to estimate the changes in principal analytes with food intake, time in captivity and acute trauma associated with hot-iron branding and transmitter implant surgery. Of the 17 blood parameters examined, physiological changes for juvenile sea lions were best described using the following six principal analytes: red blood cell counts, white blood cell counts, globulin, platelets, glucose and total bilirubin. The white blood cell counts and total bilirubin declined over time in captivity, whereas globulin increased. Elevated red blood cell counts, white blood cell counts and total bilirubin and reduced globulin values were associated with lower food intake. After branding, white blood cell counts were elevated for the first 30 days, while globulin and platelets were elevated for the first 15 days only. After implant surgery, red blood cell counts and globulin remained elevated for 30 days, while white blood cell counts remained elevated during the first 15 days only. Glucose was unassociated with the factors we studied. These results were used to provide expected ranges for principal analytes at different levels of food intake and in response to the physical challenges of branding and implant surgery

  3. Comparative evaluation of platelet count and antimicrobial efficacy of injectable platelet-rich fibrin with other platelet concentrates: An in vitro study

    Directory of Open Access Journals (Sweden)

    Prerna Ashok Karde

    2017-01-01

    Full Text Available Background: Platelet concentrates are used in various medical procedures to promote soft- and hard-tissue regeneration. In recent times, their antimicrobial efficacy is also explored. However, various platelet concentrates have evolved which differ in the centrifugation protocols. One such recently introduced platelet concentrate is injectable platelet-rich fibrin (i-PRF concentrate. Hence, the aim was to evaluate the antimicrobial property, and platelet count of i-PRF in comparison to other platelet concentrates, i.e., PRF, platelet-rich plasma (PRP, and control (whole blood. Materials and Methods: Blood samples were obtained from 10 chronic generalized marginal gingivitis patients. Platelet concentrates were prepared using standardized centrifugation protocol. Platelet count was evaluated by manual counting method using smear preparation of each sample. Subsequently, antimicrobial activity against oral bacteria was examined on blood agar using disc diffusion method to quantify the inhibitory effects. Results: Statistical significance was analyzed by one-way analysis of variance (ANOVA. P 0.05. i-PRF showed statistically significant difference (P < 0.001 in platelet count when compared to control. It was also significant when compared to PRP (P < 0.01, PRF (P < 0.001. Conclusion: i-PRF has maximum antimicrobial efficacy and higher platelet count in comparison to other platelet concentrates, thereby indicating to have a better regenerative potential then others.

  4. Hip Synovial Fluid Cell Counts in Children From a Lyme Disease Endemic Area.

    Science.gov (United States)

    Dart, Arianna H; Michelson, Kenneth A; Aronson, Paul L; Garro, Aris C; Lee, Thomas J; Glerum, Kimberly M; Nigrovic, Peter A; Kocher, Mininder S; Bachur, Richard G; Nigrovic, Lise E

    2018-05-01

    Patients with septic hip arthritis require surgical drainage, but they can be difficult to distinguish from patients with Lyme arthritis. The ability of synovial fluid white blood cell (WBC) counts to help discriminate between septic and Lyme arthritis of the hip has not been investigated. We assembled a retrospective cohort of patients ≤21 years of age with hip monoarticular arthritis and a synovial fluid culture obtained who presented to 1 of 3 emergency departments located in Lyme disease endemic areas. Septic arthritis was defined as a positive synovial fluid culture result or synovial fluid pleocytosis (WBC count ≥50 000 cells per µL) with a positive blood culture result. Lyme arthritis was defined as positive 2-tiered Lyme disease serology results and negative synovial fluid bacterial culture results. All other patients were classified as having other arthritis. We compared median synovial fluid WBC counts by arthritis type. Of the 238 eligible patients, 26 (11%) had septic arthritis, 32 (13%) had Lyme arthritis, and 180 (76%) had other arthritis. Patients with septic arthritis had a higher median synovial fluid WBC count (126 130 cells per µL; interquartile range 83 303-209 332 cells per µL) than patients with Lyme arthritis (53 955 cells per µL; interquartile range 33 789-73 375 cells per µL). Eighteen patients (56%) with Lyme arthritis had synovial fluid WBC counts ≥50 000 cells per µL. Of the 94 patients who underwent surgical drainage, 13 were later diagnosed with Lyme arthritis. In Lyme disease endemic areas, synovial fluid WBC counts cannot always help differentiate septic from Lyme arthritis. Rapid Lyme diagnostics could help avoid unnecessary operative procedures in patients with Lyme arthritis. Copyright © 2018 by the American Academy of Pediatrics.

  5. [Reference values of neonatal erythrocyte and leukocyte count in Bamako, Mali].

    Science.gov (United States)

    Diallo, Dapa Aly; Diawara, Faoumata; Guindo, Aldiouma; Touré, Moustaph; Traoré, Mamadou; Fofana, Aïssata Traoré; Dembélé, Albdoul K; Guindo, Agnès; Diallo, Yacouba Lazare; Diallo, Oumahane; Baraika, Ag Mohamed; Dolo, Amadou Ingré

    2013-01-01

    Reference values for blood cell count are not established at birth in Mali. This study aimed to determine reference values for erythrocyte and leukocyte at birth in Bamako. Blood was collected from the umbilical cord immediately following its clamping and studied for complete blood cell count in 481 newborns with a birth weight > 2500g, Apgar score ≤ 7 at 5 or 10 minutes, without abnormal hemoglobin mutations and whose mothers were willing in Bamako, Mali. Other than the median and mean values, 2.5 and 97.5 percentiles were calculated. The findings suggest that the normal reference values following a timely clamping of the umbilical cord were (mean ± 1SD and range): RBC = 4,00 ± 0,46.1012/L (3,13 - 4,89), Hb = 14,12 ± 1,49 g/dL (11,20 - 17,00), Hct = 40,27 ± 4,71% (31,62 - 50,18), MCV = 101 ± 5 fl (91 - 112), MCHC = 35,37 ± 2,16 pg/cellule (30,70 - 39,59), MCH = 35,06 ± 0,93 g/dL (33,40 - 36,90), RDW = 17,79 ± 7,33% (15,50 - 20,39), Reticulocytes (109/L) = 133,081 ± 29,95 (66,62 - 200,86), GB (109/L) = 13,24 ± 7,23 (7,20 - 23,70), PMN (109/L) = 7,16 ± 4,70 (3,07 - 14,22), PME (109/L) = 0,28 ± 0,26 (0 - 0,98), PMB(109/L) = 0,05 ± 0,09 (0 - 0,31), Lymphocytes (109/L) = 4,49 ± 2,45 (1,96 - 9,42), Monocytes (10 9 /L) = 1,06 ± 0,73 (0,21 - 2,54), myelocytes = 1.43 ± 1.51%, erythroblasts = 4.52 ± 7.83%. It should be noted that male babies had a lower neutrophil count than female newborns. By taking into account these results when interpreting the blood cell count in Malian newborn infants, costly misdiagnoses should be considerably decreased in a population struggling with low incomes. Le comitée de rédaction se réserve le droit de revoyer aux auteurs avant toute soumission à l'avis des lecteurs les manuscrits qui ne seraient pas conformes à ces modalités de présentation. En outre il leur conseille de sonserver un examplaire du manuscrit, des figures et des tableaux.

  6. Peripheral blood count in preoperative radiotherapy (with radiomodificators) of lung cancer

    International Nuclear Information System (INIS)

    Demidchik, Yu.E.; Zharkov, V.V.; Prokhorova, V.I.; Rubanova, C.Z.

    1989-01-01

    Indices of peripheral blood in 215 patients with lung cancer during preoperative radiation using hyperglycemia or metronidazole are studied. It is shown that after preoperative radiotherapy, when radiomodifying effects are not used, the content of erythrocytes, thrombocytes, leukocytes, the concentration of hemoglobin in peripheral blood, as well as erythrocyte sedimentation rare didn't change. Functional disorders of the leukopoietic function and the thrombopoietic function of bone marrow when using metronidazole are registered when applying various types of preoperative radiotherapy. Lymphopenia is established when using various types of radiotherapy with radiomodificators

  7. Evaluation of hematologic, blood gas, and select biochemical variables in ovine whole blood stored in CPDA-1 bags.

    Science.gov (United States)

    Sousa, Rejane S; Barrêto, Raimundo A; Sousa, Isadora K F; Chaves, Dowglish F; Soares, Herbert S; Barros, Isabella O; Minervino, Antonio H H; Ortolani, Enrico L

    2013-03-01

    The economic consequences from mortality of sheep after blood loss can be considerable. To date there are no reports addressing hematologic, blood gas, and biochemical changes in ovine blood stored in CPDA-1 bags. The aim of this study was to investigate hematologic, blood gas, and biochemical alterations resulting from storage of ovine blood in CPDA-1 bags to establish transfusion protocols in sheep. From each of 7 healthy 8-month-old sheep 450 mL of blood were collected into CPDA-1 bags and stored for 35 days in at 3-6°C. Samples were taken from the bags at days 0, 7, 14, 21, and 35. Whole blood was used to assess PCV, MCV, RBC count, pH, pO2 , pCO2 , and concentrations of bicarbonate, sodium, and lactate. Plasma was used to measure potassium, hemoglobin, and glucose concentrations. The PCV remained stable throughout the storage period, while plasma hemoglobin and MCV began to increase on days 7 and 21, respectively. The RBC count began to decrease on day 21. Blood pH decreased and pCO2 increased steadily throughout the storage period. Potassium concentration increased from 3.8 to 18.3 mmol/L on day 7 and remained high thereafter. In contrast, sodium concentration began to decrease on day 7. The results show that ovine blood undergoes hematologic, blood gas, and biochemical changes during storage. Further studies are required to establish RBC viability in CPDA-1 bags after a storage period of 35 days. © 2012 American Society for Veterinary Clinical Pathology.

  8. Serum inhibin-b in fertile men is strongly correlated with low but not high sperm counts: a coordinated study of 1,797 European and US men

    DEFF Research Database (Denmark)

    Jørgensen, Niels; Liu, Fan; Andersson, Anna-Maria

    2010-01-01

    To describe associations between serum inhibin-b and sperm counts, adjusted for effect of time of blood sampling, in larger cohorts than have been previously reported.......To describe associations between serum inhibin-b and sperm counts, adjusted for effect of time of blood sampling, in larger cohorts than have been previously reported....

  9. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  10. Quantifying oral inflammatory load: oral neutrophil counts in periodontal health and disease.

    Science.gov (United States)

    Landzberg, M; Doering, H; Aboodi, G M; Tenenbaum, H C; Glogauer, M

    2015-06-01

    Neutrophils are the primary white blood cells that are recruited to fight the initial phases of microbial infections. While healthy norms have been determined for circulating blood neutrophil counts in order to identify patients with suspected systemic infections, the levels of oral neutrophils (oPMNs) in oral health and in the presence of periodontal diseases have not been described. It is important to address this deficiency in our knowledge as neutrophils are the primary immune cell present in the crevicular fluid and oral environment and previous work has suggested that they may be good indicators of overall oral inflammation and periodontal disease severity. The objective of this study was to measure oPMN counts obtained in a standardized oral rinse from healthy patients and from those with chronic periodontal disease in order to determine if oPMN levels have clinical relevance as markers of periodontal inflammation. A parallel goal of this investigation was to introduce the concept of 'oral inflammatory load', which constitutes the inflammatory burden experienced by the body as a consequence of oral inflammatory disease. Periodontal examinations of patients with a healthy periodontium and chronic periodontal disease were performed (n = 124). Two standardized consecutive saline rinses of 30 s each were collected before patient examination and instrumentation. Neutrophils were quantified in the rinse samples and correlated with the clinical parameters and periodontal diagnosis. Average oPMN counts were determined for healthy patients and for those with mild, moderate and severe chronic periodontal diseases. A statistically significant correlation was found between oPMN counts and deep periodontal probing, sites with bleeding on probing and overall severity of periodontal disease. oPMN counts obtained through a 30-s oral rinse are a good marker of oral inflammatory load and correlate with measures of periodontal disease severity. © 2014 John Wiley & Sons A

  11. Phagocytic and bactericidal activities of leukocytes in whole blood from atomic bomb survivors

    International Nuclear Information System (INIS)

    Sasagawa, S.; Yoshimoto, Y.; Toyota, E.; Neriishi, S.; Yamakido, M.; Matsuo, M.; Hosoda, Y.; Finch, S.C.

    1990-01-01

    This study evaluated the phagocytic and bactericidal activities of peripheral blood leukocytes from Hiroshima and Nagasaki atomic bomb survivors for Staphylococcus aureus. The data were analyzed by multiple linear regression for age, sex, radiation exposure, city of exposure, and neutrophil counts. No significant radiation effect was observed for either blood phagocytic or bactericidal activities. The only significant variable for these functions was the neutrophil count

  12. Correlation between the neutrophil-lymphocyte count ratio and bacterial infection in patient with human immunodeficiency virus

    Science.gov (United States)

    Kusnadi, D.; Liwang, M. N. I.; Katu, S.; Mubin, A. H.; Halim, R.

    2018-03-01

    Parameters for starting antibiotic therapy such as CRP andleukocytosis are considered non-specific. Previous studies have shown the Neutrophil-Lymphocyte Count Ratio (NLCR) can serve as the basis of bacterial infection, the level of infection, and the basis of antibiotic therapy. Compared with the Procalcitonin parameter, this NLCR is rapid, an inexpensive and requires no additional sampling. To determine the correlation between The Neutrophil-LymphocyteCount Ratio to bacterial infection in HIV patients. This study was a cross-sectional observational approach to HIV subject at Wahidin Sudirohusodo and Hasanuddin University Hospital. The subjects performed routine blood, microbiology test,and blood Procalcitonin levels tests. Then performed NLCR calculations based on routine blood results. The subjects then grouped the presence or absence of bacterial infection.In 146 study subjects, there were 78 (53.4%) with bacterial infections and 68 (46.6%) without bacterial infection as controls. Subjects with bacterial infections had higher total neutrophils (84.83) compared with non-bacterial infections. Subjects with bacterial infections had total lymphocytes with an average of 8.51 lower than non-bacterial infections. Subjects with bacterial infections had higher NLCR values with an average of 12.80. The Neutrophil-Lymphocyte Count Ratio can become a marker of bacterial infection in HIV patients.

  13. Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts

    Directory of Open Access Journals (Sweden)

    Zainab S Al-Hosni

    2016-11-01

    Full Text Available Objectives: Manual platelet estimation is one of the methods used when automated platelet estimates are very low. However, the reproducibility of manual platelet estimation has not been adequately studied. We sought to assess the reproducibility of manual platelet estimation following automated low platelet counts and to evaluate the impact of the level of experience of the person counting on the reproducibility of manual platelet estimates. Methods: In this cross-sectional study, peripheral blood films of patients with platelet counts less than 100 × 109/L were retrieved and given to four raters to perform manual platelet estimation independently using a predefined method (average of platelet counts in 10 fields using 100× objective multiplied by 20. Data were analyzed using intraclass correlation coefficient (ICC as a method of reproducibility assessment. Results: The ICC across the four raters was 0.840, indicating excellent agreement. The median difference of the two most experienced raters was 0 (range: -64 to 78. The level of platelet estimate by the least-experienced rater predicted the disagreement (p = 0.037. When assessing the difference between pairs of raters, there was no significant difference in the ICC (p = 0.420. Conclusions: The agreement between different raters using manual platelet estimation was excellent. Further confirmation is necessary, with a prospective study using a gold standard method of platelet counts.

  14. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  15. ABO blood groups and malaria related clinical outcome.

    Science.gov (United States)

    Deepa; Alwar, Vanamala A; Rameshkumar, Karuna; Ross, Cecil

    2011-03-01

    The study was undertaken to correlate the blood groups and clinical presentations in malaria patients and to understand the differential host susceptibility in malaria. From October 2007 to September 2008, malaria positive patients' samples were evaluated in this study. Hemoglobin, total leukocyte count, and platelet count of each patient were done on an automated cell counter. After determining the blood groups, malarial species and the severity of clinical course were correlated. A total of 100 patients were included in the study, of which 63 cases were positive for Plasmodium falciparum and 37 cases were positive for P. vivax infection and 11 patients had mixed infection. The results of the blood groups showed 22 - 'A' group, 42 - 'B' group, 35 - 'O' group and 1 was 'AB' group. When the clinical courses between different groups were compared using the following parameters for severe infection--a parasitic load of >10/1000 RBCs, severe anemia with hemoglobin 101°F and other organ involvement, it was observed that 'O' group had an advantage over other the groups. The difference in rosetting ability between red blood cells of different 'ABO' blood groups with a diminished rosetting potential in blood group 'O' red blood cells was due to the differential host susceptibility. 'O' group had an advantage over the other three blood groups. Based on literature and the results of this study, the diminished rosetting potential in blood group 'O' red blood cells is suggested as the basis for the differential host susceptibility.

  16. Neonatal nucleated red blood cells in infants of overweight and obese mothers.

    Science.gov (United States)

    Sheffer-Mimouni, Galit; Mimouni, Francis B; Dollberg, Shaul; Mandel, Dror; Deutsch, Varda; Littner, Yoav

    2007-06-01

    The perinatal outcome of the infant of obese mother is adversely affected and in theory, may involve fetal hypoxia. We hypothesized that an index of fetal hypoxia, the neonatal nucleated red blood cell (NRBC) count, is elevated in infants of overweight and obese mothers. Absolute NRBC counts taken during the first 12 hours of life in 41 infants of overweight and obese mothers were compared to 28 controls. Maternal body mass index and infant birthweight were significantly higher in the overweight and obese group (P cell and lymphocyte counts did not differ between groups. The absolute NRBC count was higher (P = 0.01), and the platelet count lower (P = 0.05) in infants of overweight and obese mothers than in controls. In stepwise regression analysis, the absolute NRBC count in infants of overweight and obese mothers remained significantly higher even after taking into account birthweight or gestational age and Apgar scores (P mothers have increased nucleated red blood cells at birth compared with controls. We speculate that even apparently healthy fetuses of overweight and obese mothers are exposed to a subtle hypoxemic environment.

  17. Oral neutrophil responses to acute prolonged exercise may not be representative of blood neutrophil responses.

    Science.gov (United States)

    Davison, Glen; Jones, Arwel Wyn

    2015-03-01

    Neutrophil numbers and function (oxidative burst) were assessed in peripheral blood and oral samples before and after prolonged exercise. Blood neutrophil count increased (∼3.5-fold, P < 0.001) and function decreased (30% ± 19% decrease, P = 0.005) postexercise. Oral neutrophil count (P = 0.392) and function (P = 0.334) were unchanged. Agreement between oral and blood neutrophil function responses to exercise was poor. These findings highlight the importance of studying neutrophils within various compartments/sample types.

  18. Correlation between maternal and umbilical cord blood in pregnant women of Pokhara Valley: a cross sectional study.

    Science.gov (United States)

    Timilsina, Sameer; Karki, Sirisa; Gautam, Aajeevan; Bhusal, Pujan; Paudel, Gita; Sharma, Deepak

    2018-03-21

    Complete blood count is one of the routinely advised blood investigation during pregnancy. It is also utilized as a diagnostic tool for neonatal anemia, sepsis and determining hemostatic status of the newborn. The present study aims at estimating the complete blood count of maternal and umbilical cord blood at the time of delivery and to establish its correlation. This cross sectional study included 114 mothers and their healthy neonates born through normal vaginal delivery. Complete blood count of umbilical cord blood and maternal blood was estimated using automatic hematology analyzer. The mean maternal and neonatal hemoglobin concentration was 11.14 ± 1.39 g/dL and 16.34 ± 2.01 g/dL respectively. A significant positive correlation was found between maternal and fetal hemoglobin concentration (p correlation between maternal and fetal WBC, RBC and Platelet count was not statistically significant. A significant positive correlation was found between maternal and fetal MCV and MCH while PCV showed a non-significant positive correlation. There was moderately positive correlation between maternal and fetal hemoglobin, MCV and MCH. The cord blood hemoglobin was lower in babies born to anemic mothers. The decrease in hemoglobin followed the severity of anemia, however, the correlation did not exist in anemic mothers. It suggested that fetal hematological parameters are not reflective of maternal hemogram.

  19. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  20. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  1. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  2. Thrombocytopenia responding to red blood cell transfusion

    International Nuclear Information System (INIS)

    Mubarak, Ahmad A.; Awidi, Abdalla; Rasul, Kakil I.; Al-Homsi, Ussama

    2004-01-01

    Three patients with severe symptomatic iron defficiency anemia and thrombocytopenia had a significant rise in the platelet count a few days following packed red blood cell transfusion. Pretransfusion platelet count of of patient one was 17x10/L. 22x10/Lin patient two and 29x10/L in patient three. On the 6th day of post tranfusion, the platelet count rose to 166x10/Lin patient one, 830x10/L in patient two and 136x10/L in patient three. The possible mechcnism behind such an unreported observation are discussed. (author)

  3. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  4. Daily variation in radiosensitivity of circulating blood cells and bone marrow cell density in mice

    International Nuclear Information System (INIS)

    Tabatabai, R.N.

    1984-01-01

    Mice on a 12/12 light/dark cycle were bled during a twenty-four hour period each week for eight weeks to establish daily values of circulating blood cells. No significant daily variation was found in total red blood cells, hematocrit, or percentage of reticulocytes. A significant (P < 0.001) daily variation was found in total white blood cells, with the minimum occurring at 8 PM and the maximum occurring during the daylight hours from 8 a.m. to 2 p.m. Mice were then exposed to 0 R, 20 R, 50 R, or 100 R of x-radiation to determine what dose significantly reduces the total white cell count in circulating blood. It was found that 100 R significantly (P < .05) reduces the total white cell count over a four week period post-exposure. To determine if circulating blood cells and bone marrow cells show a diurnal radiosensitivity, mice were exposed to 100 R or 200 R of x-radiation at noon or midnight. Hematocrits, reticulocyte and white blood cell counts, daily white blood cell rhythm, and bone marrow cell density indicate that these mice were more radiosensitive at night

  5. Performance evaluation of XN-1000 Sysmex blood cell count of low value of white blood cell%Sysmex XN-1000血细胞分析仪计数低值白细胞性能的评估

    Institute of Scientific and Technical Information of China (English)

    蒋清清; 马萍; 丁爽

    2016-01-01

    目的:探讨 Sysmex XN‐1000(后简称 XN‐1000)全自动血细胞分析仪检测白细胞计数(WBC)及分类的准确性。方法收集该院2015年1~4月门诊及住院患者及健康体检者共206例,根据人工镜检检测 WBC 结果分为高值组(WBC >10.0×109/L),健康组(4.0×109/L < WBC ≤10.0×109/L)和低值组(1.5×109/L < WBC ≤4.0×109/L)。再分别用 XN‐1000与Sysmex XE‐5000(后简称 XE‐5000)进行 WBC 并分类。采用统计学软件对3种方法的结果进行对比分析,并进行相关性分析。结果3种方法检测 WBC 结果比较,高值组和健康组差异无统计学意义(P>0.05),结果具有正相关性。低值组中,XN‐1000检测结果准确性与 XE‐5000差异无统计学意义(P>0.05),但是白细胞分类结果显著高于 XE‐5000(P<0.05);对于异常细胞,XN‐1000和 XE‐5000不能进行有效分类,仍需人工镜检进行分类。结论 XN‐1000全自动血细胞分析仪在 WBC 与 XE‐5000及人工镜检比较无差异统计学意义,在测定白细胞分类上 XN‐1000较 XE‐5000更准确(XN‐1000合格率91%,XE‐5000合格率63%),但仍不能完全替代人工镜检。对于异常细胞,XN‐1000不能有效分类,需与人工镜检结合。%Objective To investigate the accuracy of XN‐1000 automatic blood cell analyzer in detecting of white blood cell (WBC) count and classification .Methods A total of 206 cases including outpatients ,inpatients and health people were collected in the hospital from January to April 2015 .According to manual microscopy detection of white blood cell count results ,the cases were divided into three groups :high value of white blood cell(WBC was more than 10 .0 × 109 /L) group ,normal value of white blood cells group(WBC was more than 4 .0 × 109 /L but less than 10 .0 × 109 /L) and low value of white blood cell(WBC was more than 1 .5 × 109 /L

  6. Allogeneic Peripheral Blood Stem Cell Harvest

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Allogeneic Peripheral Blood Stem Cell Harvest. Mobilization protocol. G-CSF 10 mcg/Kg / day for 5 days. Pheresis. Cobe Spectra; Haemonetics mcs+. Enumeration. CD34 counts; Cfu-GM assays.

  7. A Microfluidic Cytometer for Complete Blood Count With a 3.2-Megapixel, 1.1- μm-Pitch Super-Resolution Image Sensor in 65-nm BSI CMOS.

    Science.gov (United States)

    Liu, Xu; Huang, Xiwei; Jiang, Yu; Xu, Hang; Guo, Jing; Hou, Han Wei; Yan, Mei; Yu, Hao

    2017-08-01

    Based on a 3.2-Megapixel 1.1- μm-pitch super-resolution (SR) CMOS image sensor in a 65-nm backside-illumination process, a lens-free microfluidic cytometer for complete blood count (CBC) is demonstrated in this paper. Backside-illumination improves resolution and contrast at the device level with elimination of surface treatment when integrated with microfluidic channels. A single-frame machine-learning-based SR processing is further realized at system level for resolution correction with minimum hardware resources. The demonstrated microfluidic cytometer can detect the platelet cells (< 2 μm) required in CBC, hence is promising for point-of-care diagnostics.

  8. Effect of Tree Leaves on Rumen Fermentation, Microbial Count and Blood Urea Nitrogen of West African Dwarf Goats

    Directory of Open Access Journals (Sweden)

    Adelusi, O. O.

    2016-12-01

    Full Text Available This experiment was carried out to assess the effect of Azadirachta indica, Newbouldia laevis and Spondias mombin leaves on rumen fermentation, microbial count and blood urea nitrogen (BUN of West African Dwarf (WAD goats. Sixteen WAD bucks (11.6 ? 0.9 kg in body weight were allocated to 4 treatments: 1 Control and 2 40 g/day of Azadirachta indica, 3 40 g/day of Newbouldia laevis and 4 40 g/day of Spondias mombin leaves arranged in a completely randomised design. The ground leaves were included in concentrate diets served on dry matter basis at 2% of body weight while Panicum maximum was fed ad libitum. The control diet had no tree leaves. Data were collected on chemical composition, rumen fermentation and microbial ecology, and BUN. Saponin was highest (P < 0.05 in S. mombin (8.14% while A. indica and N. laevis had 5.78% and 1.56%, respectively. Rumen ammonia nitrogen was least (P < 0.05 in goats fed A. indica (8.35 mg/dL while the highest (P < 0.05 total volatile fatty acid (TVFA was obtained from goats fed S. mombin with 125.51 mM. Goats fed N. laevis yielded the highest (P < 0.05 acetate with 70.65 mol/100 mol while propionate production was highest (P < 0.05 in the rumen of goats fed S. mombin (27.15 mol/100 mol. Viable bacteria count was lowest (P < 0.05 in rumen of goats fed A. indica (3.95?1012 cfu/ml while the least (P < 0.05 protozoa population was obtained from the rumen of bucks fed S. mombin (4.18?109 cfu/ml. All goats in the treatments containing tree leaves had higher (P < 0.05 and a rapid increase in BUN between 0 and 6 h post feeding when compared with the Control. It is concluded that feeding ground leaves of S. mombin to goats increases rumen total volatile fatty acid and propionate production and reduces the protozoa population.

  9. Neonatal nucleated red blood cells in G6PD deficiency.

    Science.gov (United States)

    Yeruchimovich, Mark; Shapira, Boris; Mimouni, Francis B; Dollberg, Shaul

    2002-05-01

    The objective of this study is to study the absolute number of nucleated red blood cells (RBC) at birth, an index of active fetal erythropoiesis, in infants with G6PD deficiency and in controls. We tested the hypothesis that hematocrit and hemoglobin would be lower, and absolute nucleated RBC counts higher, in the G6PD deficient and that these changes would be more prominent in infants exposed passively to fava bean through maternal diet. Thirty-two term infants with G6PD deficiency were compared with 30 term controls. Complete blood counts with manual differential counts were obtained within 12 hours of life. Absolute nucleated RBC and corrected leukocyte counts were computed from the Coulter results and the differential count. G6PD deficient patients did not differ from controls in terms of gestational age, birth weight, or Apgar scores or in any of the hematologic parameters studied, whether or not the mother reported fava beans consumption in the days prior to delivery. Although intrauterine hemolysis is possible in G6PD deficient fetuses exposed passively to fava beans, our study supports that such events must be very rare.

  10. Effects of chronic sucralose sweetener on the labeling of blood constituents with technetium-99m, morphology of red blood cells and the biodistribution of sodium pertechnetate in rats

    International Nuclear Information System (INIS)

    Rocha, Gabrielle de Souza; Pereira, Marcia de Oliveira; Frydman, Jacques Natan Grinapel; Benarroz, Monica de Oliveira; Garcia-Pinto, Angelica Beatriz; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario; Pereira, Mario Jose

    2008-01-01

    This work evaluates effects of the sweetener with sucralose on the labeling of blood constituents with technetium- 99m ( 99m Tc), on the morphology of red blood cells (RBC) and on the biodistribution of sodium pertechnetate in Wistar rats. Animals were treated with sweetener for 8 days. Blood samples were withdrawn and the assay of labeling of blood constituents with 99m Tc was performed. Blood cells (BC) and plasma (P) were isolated. Aliquots of BC and P were also precipitated, soluble and insoluble fractions separated. The radioactivity in each fraction was counted and percentage of incorporated radioactivity (%ATI) determined. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphology of the RBC was evaluated under optical microscopy. In biodistribution experiments, sodium pertechnetate was administrated, organs and tissues isolated, radioactivity was counted and percentage of incorporated radioactivity per gram (%ATI/g) determined. The data showed no significant alterations in %ATI, morphology of RBC and in %ATI/g in the studied organs. (author)

  11. Effects of chronic sucralose sweetener on the labeling of blood constituents with technetium-99m, morphology of red blood cells and the biodistribution of sodium pertechnetate in rats

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Gabrielle de Souza; Pereira, Marcia de Oliveira; Frydman, Jacques Natan Grinapel [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Centro de Ciencias da Saude; Benarroz, Monica de Oliveira; Garcia-Pinto, Angelica Beatriz; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Instituto de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria]. E-mail: adenilso@uerj.br; Pereira, Mario Jose [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. de Fisiologia

    2008-12-15

    This work evaluates effects of the sweetener with sucralose on the labeling of blood constituents with technetium- 99m ({sup 99m}Tc), on the morphology of red blood cells (RBC) and on the biodistribution of sodium pertechnetate in Wistar rats. Animals were treated with sweetener for 8 days. Blood samples were withdrawn and the assay of labeling of blood constituents with {sup 99m}Tc was performed. Blood cells (BC) and plasma (P) were isolated. Aliquots of BC and P were also precipitated, soluble and insoluble fractions separated. The radioactivity in each fraction was counted and percentage of incorporated radioactivity (%ATI) determined. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphology of the RBC was evaluated under optical microscopy. In biodistribution experiments, sodium pertechnetate was administrated, organs and tissues isolated, radioactivity was counted and percentage of incorporated radioactivity per gram (%ATI/g) determined. The data showed no significant alterations in %ATI, morphology of RBC and in %ATI/g in the studied organs. (author)

  12. Utility of the point of care CD4 analyzer, PIMA, to enumerate CD4 counts in the field settings in India

    Directory of Open Access Journals (Sweden)

    Thakar Madhuri

    2012-09-01

    Full Text Available Abstract Background In resource limited settings non-availability of CD4 count facility at the site could adversely affect the ART roll out programme. Point of care CD4 enumerating equipments can make the CD4 count available at the site of care and improve the patients’ management considerably. This study is aimed at determining the utility of a Point of Care PIMA CD4 analyzer (Alere, Germany in the field settings in India. Method The blood samples were collected from 1790 participants at 21 ART centers from different parts of the country and tested using PIMA and the reference methods (FACSCalibur, FACSCount and CyFlow SL3. The paired finger prick and venous blood samples from 175 participants were tested by the PIMA CD4 Analyzer and then by FACSCalibur. Result The CD4 counts obtained by PIMA CD4 analyzer showed excellent correlation with the counts obtained by the reference methods; for venous blood the Pearson’s r was 0.921, p 500 cells/mm3, the differences in the median CD4 counts obtained by the reference method and the PIMA analyzer were not significant (P > 0.05 and the relative bias were low (−7 to 5.1%. The Intermachine comparison showed variation within the acceptable limit of%CV of 10%. Conclusion In the field settings, the POC PIMA CD4 analyzer gave CD4 counts comparable to the reference methods for all CD4 ranges. The POC equipment could identify the patients eligible for ART in 91% cases. Adequate training is necessary for finger prick sample collection for optimum results. Decentralization of CD4 testing by making the CD4 counts available at primary health centers, especially in remote areas with minimum or no infrastructure would reduce the missed visits and improve adherence of the patients.

  13. Eosinophil count, allergies, and rejection in pediatric heart transplant recipients.

    Science.gov (United States)

    Arbon, Kate S; Albers, Erin; Kemna, Mariska; Law, Sabrina; Law, Yuk

    2015-08-01

    Allograft rejection and long-term immunosuppression remain significant challenges in pediatric heart transplantation. Pediatric recipients are known to have fewer rejection episodes and to develop more allergic conditions than adults. A T-helper 2 cell dominant phenotype, manifested clinically by allergies and an elevated eosinophil count, may be associated with immunologic quiescence in transplant recipients. This study assessed whether the longitudinal eosinophil count and an allergic phenotype were associated with freedom from rejection. This single-center, longitudinal, observational study included 86 heart transplant patients monitored from 1994 to 2011. Post-transplant biannual complete blood counts, allergic conditions, and clinical characteristics related to rejection risk were examined. At least 1 episode of acute cellular rejection (ACR) occurred in 38 patients (44%), antibody-mediated rejection (AMR) occurred in 11 (13%), and 49 patients (57%) were diagnosed with an allergic condition. Patients with ACR or AMR had a lower eosinophil count compared with non-rejectors (p = 0.011 and p = 0.022, respectively). In the multivariable regression analysis, the presence of panel reactive antibodies to human leukocyte antigen I (p = 0.014) and the median eosinophil count (p = 0.011) were the only independent covariates associated with AMR. Eosinophil count (p = 0.010) and female sex (p = 0.009) were independent risk factors for ACR. Allergic conditions or young age at transplant were not protective from rejection. This study demonstrates a novel association between a high eosinophil count and freedom from rejection. Identifying a biomarker for low rejection risk may allow a reduction in immunosuppression. Further investigation into the role of the T-helper 2 cell phenotype and eosinophils in rejection quiescence is warranted. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  14. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  15. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  16. Bisphenol S impairs blood functions and induces cardiovascular risks in rats

    Directory of Open Access Journals (Sweden)

    Sanghamitra Pal

    Full Text Available Bisphenol S (BPS is an industrial chemical which is recently used to replace the potentially toxic Bisphenol A (BPA in making polycarbonate plastics, epoxy resins and thermal receipt papers. The probable toxic effects of BPS on the functions of haemopoietic and cardiovascular systems have not been reported till to date. We report here that BPS depresses haematological functions and induces cardiovascular risks in rat. Adult male albino rats of Sprague-Dawley strain were given BPS at a dose level of 30, 60 and 120 mg/kg BW/day respectively for 30 days. Red blood cell (RBC count, white blood cell (WBC count, Hb concentration, and clotting time have been shown to be significantly (*P < 0.05 reduced in a dose dependent manner in all exposed groups of rats comparing to the control. It has also been shown that BPS increases total serum glucose and protein concentration in the exposed groups of rats. We have observed that BPS increases serum total cholesterol, triglyceride, glycerol free triglyceride, low density lipoprotein (LDL and very low density lipoprotein (VLDL concentration, whereas high density lipoprotein (HDL concentration has been found to be reduced in the exposed groups. BPS significantly increases serum aspartate aminotransferase (AST, alanine aminotransferase (ALT and alkaline phosphatase (ALP activities dose dependently. Moreover, serum calcium, bilirubin and urea concentration have been observed to be increased in all exposed groups. In conclusion, BPS probably impairs the functions of blood and promotes cardiovascular risks in rats. Keywords: Bisphenol S, Red blood cell count, White blood cell count, Clotting time, LDL cholesterol, HDL cholesterol, Cardiovascular risks

  17. Effect of blood collection technique in mice on clinical pathology parameters.

    Science.gov (United States)

    Schnell, Michael A; Hardy, Christine; Hawley, Melanie; Propert, Kathleen Joy; Wilson, James M

    2002-01-01

    A study was conducted in normal healthy C57BL/6 mice to determine the effect of method of blood collection on clinical pathology parameters and to provide value ranges for these parameters. Males and females were used and were randomly assigned to treatment groups based upon phlebotomy method. The blood was collected using one of four methods: intracardiac (IC), a single attempt at collection from the caudal vena cava (VC), collection from the caudal vena cava with collection of any extravasated blood from the peritoneum (MC), or retroorbital phlebotomy (RO). Evaluation of blood and serum samples was conducted for a number of serum biochemistries including liver function tests and complete blood count with differentials and platelet counts. Female mice demonstrated higher values for red blood cell number, hemoglobin (p values for platelet counts, specific white blood cell numbers (total, neutrophil, lymphocyte, and eosinophil counts), globulin, amylase, and the BUN/creatinine ratio. Overall, the VC method was associated with the least variation in both sexes and appeared slightly better than the IC method for the parameters evaluated. The largest difference between groups was noted for the transaminase levels. While alanine aminotransferase (ALT) values were similar between the IC and VC groups, aspartate aminotransferase (AST) values were associated with less variation for the VC method. Transaminase levels for the MC and RO groups were associated with relatively large ranges and variation. ALT results from the RO method, the only method amenable to repetitive sample collection used in this evaluation, indicate that this is an acceptable method. The results demonstrate the substantial impact that phlebotomy method has on the assay results and that the VC or IC methods provide the most consistent results. The ranges by collection method and sex provided here can be used to select the preferred method of collection when designing a study and for comparison of data

  18. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  19. Complete Blood Count Reference Values of Cord Blood in Taiwan and the Influence of Gender and Delivery Route on Them

    Directory of Open Access Journals (Sweden)

    Yu-Hsun Chang

    2011-06-01

    Conclusion: We successfully obtained the normal CBC and WBC DC reference values of the cord blood in Taiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values.

  20. Count-based left ventricular volume determination utilizing a left posterior oblique view for attenuation correction

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Kalff, V.; Koral, K.

    1984-01-01

    This study aimed to determine the inherent error of the left ventricular volume measurement from the gated equilibrium blood pool scintigram utilizing the count-based technique. The study population consisted of 26 patients who had undergone biplane contrast ventriculography. The patients were imaged with a parallel-hole collimator in the left anterior oblique position showing the septum to best advantage. A reference blood sample was counted and radionuclide volumes calculated without correction for attenuation. Attenuation corrected volumes were derived with the factor 1/e/sup -/+d/, where d = distance from skin marker to center of the left ventricle in the orthogonal left posterior oblique view and μ = linear attenuation coefficient. A series of μ values from 0.08 to 0.15 cm -1 was evaluated. The tightest 95% confidence limits achieved for an end-diastolic 150-ml ventricle were +/- 44ml, and for an end-systolic 75-ml ventricle +/- 32 ml. In view of the magnitude of inherent error, the count-based volume measurement may be more suitable for group analyses and in cases in which an individual patient serves as his own control

  1. Revisiting acute normovolemic hemodilution and blood transfusion during pediatric cardiac surgery: a prospective observational study.

    Science.gov (United States)

    Sebastian, Roby; Ratliff, Todd; Winch, Peter D; Tumin, Dmitry; Gomez, Daniel; Tobias, Joseph; Galantowicz, Mark; Naguib, Aymen N

    2017-01-01

    The majority of allogeneic transfusions occur in the perioperative setting, especially during cardiac surgery. In addition to the economic implications, there is emerging evidence that blood transfusion may increase both morbidity and mortality. Acute normovolemic hemodilution (ANH) may limit the need for blood products. The primary objective of this study was to determine if the method of blood collection (syringe or bag) during the ANH process impacted the platelet count and function. The secondary objectives included the need for perioperative blood transfusions during the procedure and in the intensive care unit. In addition, we assessed these outcomes' associations with ANH parameters including the method of collection, time of storage, and volume removed. Data were collected prospectively from 50 patients undergoing cardiac surgery on cardiopulmonary bypass over a 6-month period. Platelet count and function were measured for the ANH blood immediately after collection and again prior to transfusing to the patient at the end of cardiopulmonary bypass. Other data collected included ANH volume, length of storage, and the quantity of all blood products given throughout the perioperative period. No change in platelet count or function was noted regardless of the length of time or collection method for the ANH blood. Twenty-three patients received blood or blood products in the operating room or the intensive care unit, while 27 patients received no blood transfusion during their entire hospitalization. Higher ANH volume (ml·kg -1 ) and longer storage time were associated with a greater need for intraoperative transfusions. Acute normovolemic hemodilution protects the platelets from the untoward effects of cardiopulmonary bypass and offers an important autologous blood product that improves hemostasis at the conclusion of surgery. Platelet count and function are preserved regardless of the method of collection or the length of storage. The volume of ANH removed

  2. Blood leukocyte responses to extracorporeal circulation. 3. Long term extracorporeal circulation without and with irradiation in normal and splenectomized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, P.; Fliedner, T.M. (Ulm Univ. (Germany, F.R.). Abt. Klinische Physiologie)

    1983-01-01

    Long term (12-48 h) extracorporeal circulation without and with irradiation of the blood was performed in normal and splenectomized dogs in order to observe the effect of these procedures on blood leukocyte counts including CFU-C. A transient granulocytopenia and a decrease of lymphocyte count were observed. The blood CFU-C level diminished to a very low level and remained low for the whole time of the experiments. There was no significant difference between the results of procedures with or without irradiation. The similar effect of a shortened tubing system on the blood leukocyte count is also reported. Heparin infusion alone did not decrease the peripheral CFU-C concentration. The possible explanations for the observed phenomena are discussed.

  3. The effect of Ramadan fasting on tuberculin skin test and leukocyte count

    Directory of Open Access Journals (Sweden)

    Jafar Nasiri

    2017-03-01

    Full Text Available Background & Objectives: Annually, many Muslims fast during the month of Ramadan worldwide. This practice has different favorable medical and physiological effects, such as improved serum lipid profile and blood glucose level due to changes in diet and sleep patterns. It has also been hypothesized that Ramadan fasting may affect the immune system. As reported, Ramadan fasting can influence the immunoglobulin and cytokine levels. Accordingly, tuberculin skin test or purified protein derivative (PPD test, which is a delayed-type hypersensitivity of cellular immune response, may also be affected by Ramadan fasting. Regarding this, the present study aimed to investigate the alteration of PPD test during and after Ramadan. Materials & Methods: A total of 42 males (seminary students who fasted during Ramadan in 2006 were included in the study; however, only 28 cases completed the study. For data collection, the participants underwent blood and tuberculin tests at the fourth week of Ramadan and three months after this month. The white blood cell (WBC count and the tuberculin induration were recorded and compared between the two intervals to evaluate the changes. Results: According to the results of the study, the mean age of the participants was 19.21±3.83 years. Furthermore, the mean tuberculin induration was 9.3±5.4 mm (size range: 2-22 mm on the fourth week of Ramadan, which increased to 9.79±6.8 mm (size range: 3-35 mm three months after this month (P=0.501. The mean count of WBC decreased insignificantly from 5907±1879 mcL to 5601±1362 mcL after Ramadan (P=0.334. Additionally, the mean lymphocytes count decreased significantly from 2292±520/mcL to 2023±486/mcL after this month (P=0.003. Likewise, the lymphocyte (P=0.014 and mean neutrophil percentage also reduced significantly (P0.05. Conclusion: As the findings of the present study indicated, Ramadan fasting induce some changes in the immune status, including lymphocyte and neutrophil

  4. Thrombocytopenia in malaria: can platelet counts differentiate malaria from other infections

    International Nuclear Information System (INIS)

    Arshad, A.R.

    2015-01-01

    To determine the accuracy of thrombocytopenia as a diagnostic marker for malaria. Study Design: Cross-sectional study. Place and Duration of Study: Department of Medicine, 1 Mountain Medical Battalion (Bagh, Azad Kashmir) from July to September 2013. Methodology: Adult patients presenting with a short history of fever without any localizing symptoms or signs were included. Exclusion criteria included patients with fever of > 7 days duration, those in whom an underlying diagnosis could be easily confirmed on the basis of history and physical examination, those on antibiotics/ antimalarials or antiplatelet agents and patients with Dengue fever. Platelet counts in venous whole blood samples were analysed with Sysmex KX-21 Haematology analyzer. Thick and thin peripheral blood smears were then prepared and examined for malarial parasites. Diagnosis of malaria was established on the basis of smear findings. Results: There were 245 patients in total. Out of the 109 patients with thrombocytopenia, 61 had vivax malaria. Platelets count was normal in 136 patients, including 4 with vivax malaria. Falciparum malaria was not seen in any patient. All cases with malaria were uncomplicated. Various measures of accuracy thus calculated were sensitivity 93.85%, specificity 73.33%, positive predictive value 55.96%, negative predictive value 97.06%, positive likelihood ratio of 3.52, negative likelihood ratio of 0.08, diagnostic odds ratio 41.94 and diagnostic accuracy of 78.78%. Conclusion: Thrombocytopenia has an excellent sensitivity and a very good specificity for vivax malaria. Normal platelet counts provide very strong evidence against malaria as the etiology of fever without a focus. (author)

  5. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  6. Correlation between mastitis occurrence and the count of microorganisms in bulk raw milk of bovine dairy herds in four selective culture media.

    Science.gov (United States)

    Souto, Luís I M; Minagawa, Clarice Y; Telles, Evelise O; Garbuglio, Márcio A; Amaku, Marcos; Melville, Priscilla A; Dias, Ricardo A; Sakata, Sonia T; Benites, Nilson R

    2010-02-01

    Milk is the normal secretion of the mammary gland, practically free of colostrum and obtained by the complete milking of one or more healthy animals. Mastitis is an inflammatory process of the mammary gland and it may cause alterations in the milk. The present work aimed to verify whether it is possible, by means of the counts of microorganism in the bulk raw milk in four selective culture media, to establish a correlation with the occurrence of mastitis and therefore, to monitor this disease in bovine dairy herds. The following selective culture media were used: KF Streptococcus Agar, Edwards Agar, Baird-Parker Agar, Blood Agar plus potassium tellurite. Spearman's correlation coefficient was calculated in order to compare the occurrence of mastitis (percentage) in each herd with respective selective culture media counts of microorganisms in bulk raw milk. Thirty-six possibilities were analysed (Tamis and CMT-positive rates were compared with the log-transformed count in four selective culture media) and there was a negative correlation between Tamis 3 and the Baird-Parker Agar plate count. The total results of microbiological tests showed that there were three correlations of the counts in selective culture media. Fifty-two possibilities were analysed and there was a negative correlation between no-bacterial-growth mastitis rates and log10 of KF Streptoccocus Agar plate count and there were two positive correlations between coagulase-positive staphylococci and log10 of Baird-Parker Agar plate count and Blood Agar plus potassium tellurite plate count.

  7. Reference ranges for blood concentrations of nucleated red blood cells in neonates.

    Science.gov (United States)

    Christensen, Robert D; Henry, Erick; Andres, Robert L; Bennett, Sterling T

    2011-01-01

    Previous studies reported a relationship between high nucleated red blood cells (NRBC) in neonates and the development of intraventricular hemorrhage (IVH) and/or retinopathy of prematurity (ROP). We sought to (1) establish reference ranges for NRBC in neonates based on a large data set, (2) compare NRBC from automated versus manual counts, (3) determine the effect of an elevated NRBC, on the day of birth, on the odds of developing grade ≥3 IVH or ROP. We analyzed all NRBC obtained during 8.5 years in a multihospital system, displaying the 5th and 95th percentile limits according to gestational age and postnatal age. NRBC counts were retrieved from 61,932 neonates, 26,536 of which were excluded from the data set. Comparing 9,000 samples run simultaneously on manual versus automated methods, the manual counts yielded slightly higher counts, but the difference is likely insignificant clinically. Altitude of the birth hospital did not correlate with NRBC, and no correlations were observed with cord pH or 1- or 5-min Apgar. An NRBC count >95th percentile limit was associated with higher odds of developing a grade ≥3 IVH (OR 4.28; 95% CI 3.17-5.77) and grade ≥3 ROP (OR 4.18; 95% CI 2.74-6.38). The figures of this report display reference ranges for NRBC according to gestational age and postnatal age. An NRBC count above the 95% limit at birth is associated with a higher risk of subsequently developing severe IVH and severe ROP. We speculate that this association is because an elevated NRBC count is a marker for prenatal hypoxia. Copyright © 2010 S. Karger AG, Basel.

  8. The distribution of blood eosinophil levels in a Japanese COPD clinical trial database and in the rest of the world

    Science.gov (United States)

    Ishii, Takeo; Hizawa, Nobuyuki; Midwinter, Dawn; James, Mark; Hilton, Emma; Jones, Paul W

    2018-01-01

    Background Blood eosinophil measurements may help to guide physicians on the use of inhaled corticosteroids (ICS) for patients with chronic obstructive pulmonary disease (COPD). Emerging data suggest that COPD patients with higher blood eosinophil counts may be at higher risk of exacerbations and more likely to benefit from combined ICS/long-acting beta2-agonist (LABA) treatment than therapy with a LABA alone. This analysis describes the distribution of blood eosinophil count at baseline in Japanese COPD patients in comparison with non-Japanese COPD patients. Methods A post hoc analysis of eosinophil distribution by percentage and absolute cell count was performed across 12 Phase II–IV COPD clinical studies (seven Japanese studies [N=848 available absolute eosinophil counts] and five global studies [N=5,397 available eosinophil counts] that included 246 Japanese patients resident in Japan with available counts). Blood eosinophil distributions were assessed at baseline, before blinded treatment assignment. Findings Among Japanese patients, the median (interquartile range) absolute eosinophil count was 170 cells/mm3 (100–280 cells/mm3). Overall, 612/1,094 Japanese patients (56%) had an absolute eosinophil count ≥150 cells/mm3 and 902/1,304 Japanese patients (69%) had a percentage eosinophil ≥2%. Among non-Japanese patients, these values were 160 (100–250) cells/mm3, 2,842/5,151 patients (55%), and 2,937/5,155 patients (57%), respectively. The eosinophil distribution among Japanese patients was similar to that among non-Japanese patients. Within multi-country studies with similar inclusion criteria, the eosinophil count was numerically lower in Japanese compared with non-Japanese patients (median 120 vs 160 cells/mm3). Interpretation The eosinophil distribution in Japanese patients seems comparable to that of non-Japanese patients; although within multi-country studies, there was a slightly lower median eosinophil count for Japanese patients compared with

  9. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  10. Blood count in new onset atrial fibrillation after acute myocardial infarction - A hypothesis generating study

    Directory of Open Access Journals (Sweden)

    Klaus Distelmaier

    2014-01-01

    Interpretation & conclusions: This study shows a significant independent association between serum haemoglobin, haematocrit, erythrocyte count and occurrence of AF after AMI. However, the pathophysiologic mechanism underlying these associations and its potential clinical applicability need to be further elucidated.

  11. A simplified method for determination of radioactive iron in whole-blood samples

    DEFF Research Database (Denmark)

    Bukhave, Klaus; Sørensen, Anne Dorthe; Hansen, M.

    2001-01-01

    in humans. The overall recovery of radioiron from blood is more than 90%, and the coefficient of variation, as judged by the variation in the ratio Fe-55/Fe-59 is in the order of 4%. Combined with whole-body counting of 59Fe and direct gamma -counting of Fe-59 on blood samples, this method represents......For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method...... for simultaneous determination of Fe-55 and Fe-59 in blood, using a dry-ashing procedure and recrystallization of the remaining iron. The detection Limit of the method permits measurements of 0.1 Bq/ml blood thus allowing detection of Less than 1% absorption from a 40 kBq dose, which is ethically acceptable...

  12. A novel method for detecting and counting overlapping tracks in SSNTD by image processing techniques

    International Nuclear Information System (INIS)

    Ab Azar, N.; Babakhani, A.; Broumandnia, A.; Sepanloo, K.

    2016-01-01

    Overlapping object detection and counting is a challenge in image processing. A new method for detecting and counting overlapping circles is presented in this paper. This method is based on pattern recognition and feature extraction using “neighborhood values“ in an object image by implementation of image processing techniques. The junction points are detected by assignment of a value for each pixel in an image. As is shown, the neighborhood values for junction points are larger than the values for other points. This distinction of neighborhood values is the main feature which can be utilized to identify the junction points and to count the overlapping tracks. This method can be used for recognizing and counting charged particle tracks, blood cells and also cancer cells. The method is called “Track Counting based on Neighborhood Values” and is symbolized by “TCNV”. - Highlights: • A new method is introduced to recognize nuclear tracks by image processing. • The method is used to specify neighborhood pixels in junction points in overlapping tracks. • Enhanced method of counting overlapping tracks. • New counting system has linear behavior in counting tracks with density less than 300,000 tracks per cm"2. • In the new method, the overlap tracks can be recognized even to 10× tracks and more.

  13. Radioprotective effect of both vitamins E and / or C on some blood components of male mice

    International Nuclear Information System (INIS)

    Anwar, W.A.; El-Daway, H.A.E.; Tawfik, S.S.M.; Soliman, S.M.

    1999-01-01

    The protective effects of vitamin C and/or vitamin E on some blood components and serum level of thiobarbituric reactive substances (as indicator to level of lipid peroxidation) of irradiated male mice at dose 3 Gy sacrificed after 15,24 and 46 days of irradiation have been assessed in comparison with control and non-irradiated-treated with vitamin C and/or vitamin E groups. Vit. C, vit. E or in combination decreased the effect of irradiation on blood components and the level of thiobarbituric reactive substances, but average haemoglobin level RBC count, total WBC count, neutrophil count and lymphocyte count did not reach to the original average level even after 36 days of irradiation. Vit. E had a more protective effect than vit. C in case of total white blood cells, while vit. C was more protective in case of lymphocyte count. The combination of vitamins C and E had more protective effect than either of both vitamins alone. The decrease in lipid peroxidation products due to administration of vit. E and vit. C as antioxidants supported the theory that lipid peroxidation increased due to free radicals induced by irradiation

  14. A rare IL33 loss-of-function mutation reduces blood eosinophil counts and protects from asthma

    DEFF Research Database (Denmark)

    Smith, Dirk; Helgason, Hannes; Sulem, Patrick

    2017-01-01

    IL-33 is a tissue-derived cytokine that induces and amplifies eosinophilic inflammation and has emerged as a promising new drug target for asthma and allergic disease. Common variants at IL33 and IL1RL1, encoding the IL-33 receptor ST2, associate with eosinophil counts and asthma. Through whole......-C associates with lower eosinophil counts (β = -0.21 SD, P = 2.5×10-16, N = 103,104), and reduced risk of asthma in Europeans (OR = 0.47; 95%CI: 0.32, 0.70, P = 1.8×10-4, N cases = 6,465, N controls = 302,977). Heterozygotes have about 40% lower total IL33 mRNA expression than non...

  15. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  16. Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina)

    OpenAIRE

    Prihirunkit, Kreangsak; Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual-Anong

    2007-01-01

    Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hemato...

  17. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Rapid prototyping of centrifugal microfluidic modules for point of care blood testing

    CSIR Research Space (South Africa)

    Madzivhandila, Phophi

    2016-11-01

    Full Text Available We present modular centrifugal microfluidic devices that enable a series of blood tests to be performed towards a full blood count. The modular approach allows for rapid prototyping of device components in a generic format to complete different...

  19. Reference range for T lymphocytes populations in blood donors from two different regions in Brazil

    Directory of Open Access Journals (Sweden)

    A.J.L. Torres

    Full Text Available This study defined the normal variation range for different subsets of T-lymphocyte cells count in two different Brazilian regions. We analysed the T-lymphocytes subpopulations (CD3+, CD4+, CD8+ in blood donors of two Brazilian cities, located in North (Belem, capital state of Para, indian background and Northeast (Salvador, capital state od Bahia, African background regions of Brazil. Results were compared according to gender, stress level (sleep time lower than 8 hours/day, smoking, and alcohol intake. Lymphocytes subpopulations were measured by flow cytometry. Five hundred twenty-six blood donors from two Brazilians cities participated in the study: 450 samples from Bahia and 76 samples from Pará. Most (60% were men, 59% reported alcohol intake, 12% were smokers, and 80% slept at least 8 h/day. Donors from Bahia presented with significantly higher counts for all parameters, compared with Para. Women had higher lymphocytes levels, in both states, but only CD4+ cells count was significantly higher than men's values. Smokers had higher CD4+ counts, but sleep time had effect on lymphocytes levels only for Para's donors (higher CD3+ and CD4+ counts. That state had also, a higher proportion of donors reporting sleep time <8 h/day. The values for CD3, CD4 and CD8+ cells count were significantly higher in blood donors from Bahia than among those from Pará. Female gender, alcohol intake, stress level, and smoking were associated with higher lymphocyte counts. The use of a single reference range for normal lymphocytes count is not appropriate for a country with such diversity, like Brazil is.

  20. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  1. Hairy-cell leukemia: a rare blood disorder in Asia.

    Science.gov (United States)

    Josephine, F P; Nissapatorn, V

    2006-01-01

    We report a 68-year-old Indian man who was referred to the Hematology Unit for investigation for thrombocytopenia, an incidental finding during a pre-operative screening for prostatectomy. Physical examination was unremarkable. There was no splenomegaly, hepatomegaly or lymphadenopathy. Complete blood counts showed normal hemoglobin and total white cell count with moderate thrombocytopenia. Hairy-cell leukemia was diagnosed based on peripheral blood film, bone-marrow aspirate and trephine biopsy findings, supported by immunophenotyping results by flow cytometry. The purpose of this report is to create awareness of this uncommon presentation and to emphasize that a single-lineage cytopenia or absence of splenomegaly does not exclude the diagnosis of hairy-cell leukemia. Careful attention to morphological detail is important for early diagnosis, especially when low percentages of "hairy" cells are present in the peripheral blood and bone marrow. Early diagnosis is important to ensure that patients obtain maximum benefit from the newer therapeutic agents that have greatly improved the prognosis in this rare disorder.

  2. Factors affecting autologous peripheral blood hematopoietic stem cell collections by large-volume leukapheresis: a single center experience

    Directory of Open Access Journals (Sweden)

    Araci Massami Sakashita

    2011-06-01

    Full Text Available Objective: To evaluate factors affecting peripheral bloodhematopoietic stem cell yield in patients undergoing large-volumeleukapheresis for autologous peripheral blood stem cell collection.Methods: Data from 304 consecutive autologous peripheral bloodstem cell donors mobilized with hematopoietic growth factor (usually G-CSF, associated or not with chemotherapy, at Hospital Israelita Albert Einstein between February 1999 and June 2010 were retrospectively analyzed. The objective was to obtain at least 2 x 106CD34+ cells/kg of body weight. Pre-mobilization factors analyzedincluded patient’s age, gender and diagnosis. Post mobilizationparameters evaluated were pre-apheresis peripheral white bloodcell count, immature circulating cell count, mononuclear cell count,peripheral blood CD34+ cell count, platelet count, and hemoglobinlevel. The effect of pre and post-mobilization factors on hematopoietic stem cell collection yield was investigated using logistic regression analysis (univariate and multivariate approaches. Results: Premobilization factors correlating to poor CD34+ cell yield in univariate analysis were acute myeloid leukemia (p = 0.017 and other hematological diseases (p = 0.023. Significant post-mobilization factors included peripheral blood immature circulating cells (p = 0.001, granulocytes (p = 0.002, hemoglobin level (p = 0.016, and CD34+ cell concentration (p < 0.001 in the first harvesting day. However, according to multivariate analysis, peripheral blood CD34+ cell content (p < 0.001 was the only independent factor that significantly correlated to poor hematopoietic stem cell yield. Conclusion: In this study, peripheral blood CD34+ cell concentration was the only factor significantly correlated to yield in patients submitted to for autologous collection.

  3. Effect of an 1800 MHz electromagnetic field emitted during embryogenesis on the blood picture of one-day-old domestic hen chicks (Gallus gallus domesticus

    Directory of Open Access Journals (Sweden)

    Krzysztof Pawlak

    2018-01-01

    Full Text Available Exposure to artificial electromagnetic fields emitted mainly by mobile telephony has been steadily increasing with the development of modern technology. Haematological indices are among the most common indicators of the body’s physiological status. The aim of the study was to determine the effect of an 1800 MHz electromagnetic field emission on the blood picture of one-day-old domestic hen chicks. During the experiment, chick embryos were exposed to artificial electromagnetic fields throughout incubation for 13 ´ 2 min/day, 4 ´ 10 min/day and 1 ´ 40 min/day. After hatching, blood was collected from 10 one-day-old chicks from each group to determine: red blood cell count, haemoglobin concentration, haematocrit, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, white blood cell count, and leukocyte differential count. In addition, the heterophil/lymphocyte ratio was calculated. The present study is probably the first to show an increase in the red blood cell count, haemoglobin concentration, haematocrit, white blood cell count, segmented heterophils and the heterophil/lymphocyte ratio, and a decrease in lymphocyte percentage of embryos exposed to an 1800 MHz electromagnetic field. The observed changes may be indicative of the stress-inducing effect of EMF on living organisms.

  4. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  5. Distribution of microspheres to regions of dog lung compares well with regional flow of red blood cells

    International Nuclear Information System (INIS)

    Beck, K.C.; Rehder, K.

    1986-01-01

    Dorso-caudal areas of dog lungs are better perfused than ventral regions, independent of gravity. Could this be an artifact due to regional bias in lodging of MS. The costal surfaces of 5 isolated blood perfused left lungs of dogs [constant blood flow (F), Ppa, Ppv and Palv] were imaged (gamma camera) first after injection of 141 Ce-labeled MS (15 μ), then in 0.4 sec intervals after a bolus injection of 99 Tc-labeled red blood cells (RBC). Count rates were analyzed in 6 regions. Regional flow measured by MS (flowMS) is F times regional counts divided by total counts in the first image. Regional flow measured by RBC (flowRBC) is F times peak regional counts divided by peak total counts in the 0.4 sec images. The ratio flowMS/flow RBC was greater than 1.0 (P<0.001), suggesting a systematic difference between 1.0 (P<0.001), suggesting a systematic difference between flowMS and flow RBC. More importantly, there was no difference in flowMS/flow RBC among lung regions, allowing the authors to conclude there was no regional bias of flows

  6. Medical Laboratory Technician--Hematology, Serology, Blood Banking, and Immunohematology (AFSC 90470).

    Science.gov (United States)

    Thompson, Joselyn H.

    This three-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for medical laboratory technicians. Covered in the individual volumes are hematology (the physiology of blood, complete blood counts and related studies, erythrocyte studies, leukocyte and thrombocyte maturation, and blood…

  7. Nonreassuring fetal heart rate patterns and nucleated red blood cells in term neonates.

    Science.gov (United States)

    Kovalak, E Ebru; Dede, F Suat; Gelisen, Orhan; Dede, Hulya; Haberal, Ali

    2011-05-01

    The aim of this study was to evaluate the association between nonreassuring fetal heart rate patterns during labor and umbilical cord nucleated red blood cell counts. Nucleated red blood cell data was collected prospectively from 41 singleton term neonates presented with nonreassuring fetal heart rate patterns and/or meconium stained amniotic fluid during labor (study group) and from 45 term neonates without any evidence of nonreassuring fetal status (controls). Umbilical artery pH, blood gases and base excess were also determined to investigate the correlation between independent variables. The median nucleated red blood cells per 100 white blood cells were 13 (range 0-37) in the study group and 8 (range 0-21) in the control group. Stepwise regression analysis have identified meconium stained amniotic fluid (R(2) = 0.15, p patterns. Nucleated red blood cells in the cord blood of newborns were found to be elevated in patients with nonreassuring FHR patterns during labor. However, the wide range and the poor correlation of NRBC count with umbilical artery pH and blood gas values limit its clinical utility as a marker for fetal hypoxia.

  8. Baseline Antihypertensive Drug Count and Patient Response to Hypertension Medication Management.

    Science.gov (United States)

    Crowley, Matthew J; Olsen, Maren K; Woolson, Sandra L; King, Heather A; Oddone, Eugene Z; Bosworth, Hayden B

    2016-04-01

    Telemedicine-based medication management improves hypertension control, but has been evaluated primarily in patients with low antihypertensive drug counts. Its impact on patients taking three or more antihypertensive agents is not well-established. To address this evidence gap, the authors conducted an exploratory analysis of an 18-month, 591-patient trial of telemedicine-based hypertension medication management. Using general linear models, the effect of medication management on blood pressure for patients taking two or fewer antihypertensive agents at study baseline vs those taking three or more was compared. While patients taking two or fewer antihypertensive agents had a significant reduction in systolic blood pressure with medication management, those taking three or more had no such response. The between-subgroup effect difference was statistically significant at 6 months (-6.4 mm Hg [95% confidence interval, -12.2 to -0.6]) and near significant at 18 months (-6.0 mm Hg [95% confidence interval, -12.2 to 0.2]). These findings suggest that baseline antihypertensive drug count may impact how patients respond to hypertension medication management and emphasize the need to study management strategies specifically in patients taking three or more antihypertensive medications. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  9. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  10. Relative frequency of immature CD34+/CD90+ subset in peripheral blood following mobilization correlates closely and inversely with the absolute count of harvested stem cells in multiple myeloma patients

    Directory of Open Access Journals (Sweden)

    Balint Bela

    2017-01-01

    Full Text Available Background/Aim. Stem cells (SCs guarantee complete/longterm bone marrow (BM repopulation after SC-transplants. The aim of the study was to evaluate absolute count of total SCs (determined by ISHAGE-sequential-gating protocol – SCish and relative frequency of immature CD34+/CD90+ (CD90+SCish subset in peripheral blood (PB as predictive factors of mobilization and apheresis product (AP quality. Methods. Mobilization included chemotherapy and granulocytegrowth- factor (G-CSF. Harvesting was performed by Spectra- Optia-IDL-system. The SCsish were determined as a constitutional part of CD34+ cells in the “stem-cell-region” using FC- 500 flow-cytometer. In this study, the original ISHAGEsequential- gating protocol was modified by introduction of anti-CD90-PE monoclonal-antibody into the analysis of CD90 expression on SCish (CD90+SCish. The results were presented as a percentage of SCish per nucleated-cell count, absolute SCish count in μL of the PB or the AP, percentage of the CD90+SCish expressed to SCish and absolute CD90+SCish count in μL of the PB or the AP. Results. The absolute count of total SCish and CD90+SCish was significantly higher (p = 0.0007 and p = 0.0266, respectively in the AP than in the PB samples. The CD90+SCish/total SCish indexes from PB were higher than indexes from the AP (p = 0.039. The relative frequency of CD90+SCish showed a highly significant inverse correlation with the absolute count of total SCish in both, the PB and AP (p = 0.0003 and p = 0.0013 respectively. The relative frequency of CD90+SCish from the PB also showed a significant (p = 0.0002 inverse relationship with total SCish count in the AP. Patients with less than 10% CD90+SCish in the PB had evidently higher (p = 0.0025 total SCish count in the AP. Conclusion. We speculate that lower CD90+SCish yield in the AP is not a consequence of an inferior collection efficacy, but most likely a result of several still not fully resolved immature SC

  11. The distribution of blood eosinophil levels in a Japanese COPD clinical trial database and in the rest of the world

    Directory of Open Access Journals (Sweden)

    Barnes N

    2018-02-01

    Full Text Available Neil Barnes,1,2 Takeo Ishii,3,4 Nobuyuki Hizawa,5 Dawn Midwinter,6 Mark James,3 Emma Hilton,1 Paul Jones1,71Respiratory Medicine Franchise, GlaxoSmithKline, Brentford, UK; 2William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, London, UK; 3Medical Affairs, GlaxoSmithKline K.K., Tokyo, Japan; 4Graduate School of Medicine, Nippon Medical School, Tokyo, Japan; 5Department of Pulmonary Medicine, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan; 6Global Respiratory Department, GlaxoSmithKline, Stockley Park, UK; 7Institute of Infection and Immunity, St George’s University of London, London, UK Background: Blood eosinophil measurements may help to guide physicians on the use of inhaled corticosteroids (ICS for patients with chronic obstructive pulmonary disease (COPD. Emerging data suggest that COPD patients with higher blood eosinophil counts may be at higher risk of exacerbations and more likely to benefit from combined ICS/long-acting beta2-agonist (LABA treatment than therapy with a LABA alone. This analysis describes the distribution of blood eosinophil count at baseline in Japanese COPD patients in comparison with non-Japanese COPD patients.Methods: A post hoc analysis of eosinophil distribution by percentage and absolute cell count was performed across 12 Phase II–IV COPD clinical studies (seven Japanese studies [N=848 available absolute eosinophil counts] and five global studies [N=5,397 available eosinophil counts] that included 246 Japanese patients resident in Japan with available counts. Blood eosinophil distributions were assessed at baseline, before blinded treatment assignment.Findings: Among Japanese patients, the median (interquartile range absolute eosinophil count was 170 cells/mm3 (100–280 cells/mm3. Overall, 612/1,094 Japanese patients (56% had an absolute eosinophil count ≥150 cells/mm3 and 902/1,304 Japanese patients (69% had a percentage eosinophil ≥2%. Among non

  12. Haematological and biochemical characteristics of the splenic effluent blood in schistosomal patients undergoing splenectomy

    Directory of Open Access Journals (Sweden)

    Andy Petroianu

    Full Text Available OBJECTIVE: To assess hematological and biochemical features of splenic effluent blood and their influence on the rise of hematological values after splenectomy. METHODS: we studied 20 patients undergoing surgical treatment for schistosomatic portal hypertension. We collected blood samples for CBC, coagulation, bilirubin and albumin in the splenic vein (perioperative and peripheral blood (immediately pre and postoperative periods. RESULTS: the splenic blood showed higher values of red blood cells, hemoglobin, hematocrit, platelet count, total leukocytes, neutrophils, lymphocytes, monocytes, eosinophils and basophils, as well as reduction of laboratory coagulation parameters in relation to peripheral blood collected preoperatively. In the postoperative peripheral blood there was an increase in the overall leukocytes and in their neutrophil component, and decreased levels of basophils, eosinophils and lymphocytes. The other postoperative variables of complete blood count and coagulation tests were not different compared with the splenic blood. The albumin values were lower postoperatively when compared to preoperative and splenic blood. There were higher values of direct bilirubin in the postoperative period when compared with the preoperative and splenic blood. Postoperative indirect bilirubin was lower compared to its value in the splenic blood. CONCLUSION: hematological and biochemical values of splenic effluent blood are higher than those found in peripheral blood in the presence of schistosomal splenomegaly. However, the splenic blood effluent is not sufficient to raise the blood levels found after splenectomy.

  13. Antithrombin activity, platelet count, hemoglobin concentration and hematocrit value determined immediately before vaginal delivery among healthy women.

    Science.gov (United States)

    Morikawa, Mamoru; Yamada, Takashi; Yamada, Takahiro; Koyama, Takahiro; Akaishi, Rina; Ishikawa, Satoshi; Takeda, Masamitsu; Nishida, Ryutaro; Araki, Naoto; Minakami, Hisanori

    2012-08-01

    To determine the normal reference values for antithrombin (AT) activity, platelet count (Plt), hemoglobin concentration (Hb), and hematocrit value (Ht) immediately before vaginal delivery among healthy pregnant women with singleton pregnancies and to determine association of these blood parameters with fetal growth. A complete blood count was performed and the AT activity was examined in 300 consecutive women admitted to hospital at > or = gestational week 36 for labor pains and/or the rupture of fetal membranes. All the women were normotensive and had singleton pregnancies, and none of the women had proteinuria, a weekly weight gain > or = 0.5 kg, or other specific complications upon admission. All the women attempted a vaginal delivery. The medians (5th-95th percentile) were 90% (71-110%) for AT activity, 234x10(9)/L (150-337x10(9)/L) for Plt, 11.0 g/dL (9.5-12.8 g/dL) for Hb, and 34.0% (30.4-38.6%) for Ht. Women with an Hb value of > or = the median (11.0 g/dL) gave birth to significantly smaller infants than their counterparts. A considerable number of healthy women exhibit a reduced AT activity and/or platelet count immediately before delivery. Hemoconcentration evidenced by a raised Hb value adversely effects on infant growth. Our data may be helpful when considering the normal ranges of these blood parameters for healthy parturient women.

  14. Effects of sodium citrate and acid citrate dextrose solutions on cell counts and growth factor release from equine pure-platelet rich plasma and pure-platelet rich gel.

    Science.gov (United States)

    Giraldo, Carlos E; Álvarez, María E; Carmona, Jorge U

    2015-03-14

    There is a lack information on the effects of the most commonly used anticoagulants for equine platelet rich plasmas (PRPs) elaboration on cell counts and growth factor release from platelet rich gels (PRGs). The aims of this study were 1) to compare the effects of the anticoagulants sodium citrate (SC), acid citrate dextrose solution A (ACD-A) and ACD-B on platelet (PLT), leukocyte (WBC) and on some parameters associated to platelet activation including mean platelet volume (MPV) and platelet distribution width (PDW) between whole blood, pure PRP (P-PRP) and platelet-poor plasma (PPP); 2) to compare transforming growth factor beta 1 (TGF-β(1)) and platelet-derived growth factor isoform BB (PDGF-BB) concentrations in supernatants from pure PRG (P-PRG), platelet-poor gel (PPG), P-PRP lysate (positive control) and plasma (negative control); 3) to establish the possible correlations between all the studied cellular and molecular parameters. In all cases the three anticoagulants produced P-PRPs with significantly higher PLT counts compared with whole blood and PPP. The concentrations of WBCs were similar between P-PRP and whole blood, but significantly lower in PPP. The type of anticoagulant did not significantly affect the cell counts for each blood component. The anticoagulants also did not affect the MPV and PDW parameters. Independently of the anticoagulant used, all blood components presented significantly different concentrations of PDGF-BB and TGF-β(1). The highest growth factor (GF) concentrations were observed from P-PRP lysates, followed by PRG supernatants, PPP lysates, PPG supernatants and plasma. Significant correlations were observed between PLT and WBC counts (ρ = 0.80), PLT count and TGF-β(1) concentration (ρ = 0.85), PLT count and PDGF-BB concentration (ρ = 0.80) and PDGF-BB and TGF-β(1) concentrations (ρ = 0.75). The type of anticoagulant was not correlated with any of the variables evaluated. The anticoagulants did not

  15. Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina).

    Science.gov (United States)

    Prihirunkit, Kreangsak; Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual Anong

    2007-06-01

    Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hematological resources in wildlife animals and provides a guideline for identification of blood cells in the fishing cat.

  16. Cinnamomum zeylanicum extract on the radiolabelling of blood constituents and the morphometry of red blood cells: In vitro assay

    International Nuclear Information System (INIS)

    Benarroz, M.O.; Fonseca, A.S.; Rocha, G.S.; Frydman, J.N.G.; Rocha, V.C.; Pereira, M.O.

    2008-01-01

    Effects of Cinnamomum zeylanicum (cinnamon) on the labelling of blood constituents with technetium-99 m( 99m Tc) and on the morphology of red blood cells were studied. Blood samples from Wistar rats were incubated with cinnamon extract for 1hour or with 0.9% NaCl, as control. Labelling of blood constituents with 99m Tc was performed. Plasma (P) and blood cells (BC), soluble (SF-P and SF-BC) and insoluble (IF-P and IF-BC) fractions were separated. The radioactivity in each fraction was counted and the percentage of radioactivity incorporated (%ATI) was calculated. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphological analysis of the red blood cells was evaluated. The data showed that the cinnamon extract decreased significantly (p 99m Tc, and although our results were obtained with animals, precaution is suggested in interpretations of nuclear medicine examinations involving the labelling of blood constituents in patients who are using cinnamon

  17. Association of sputum and blood eosinophil concentrations with clinical measures of COPD severity: an analysis of the SPIROMICS cohort.

    Science.gov (United States)

    Hastie, Annette T; Martinez, Fernando J; Curtis, Jeffrey L; Doerschuk, Claire M; Hansel, Nadia N; Christenson, Stephanie; Putcha, Nirupama; Ortega, Victor E; Li, Xingnan; Barr, R Graham; Carretta, Elizabeth E; Couper, David J; Cooper, Christopher B; Hoffman, Eric A; Kanner, Richard E; Kleerup, Eric; O'Neal, Wanda K; Paine, Richard; Peters, Stephen P; Alexis, Neil E; Woodruff, Prescott G; Han, MeiLan K; Meyers, Deborah A; Bleecker, Eugene R

    2017-12-01

    Increased concentrations of eosinophils in blood and sputum in chronic obstructive pulmonary disease (COPD) have been associated with increased frequency of exacerbations, reduced lung function, and corticosteroid responsiveness. We aimed to assess whether high eosinophil concentrations in either sputum or blood are associated with a severe COPD phenotype, including greater exacerbation frequency, and whether blood eosinophils are predictive of sputum eosinophils. We did a multicentre observational study analysing comprehensive baseline data from SPIROMICS in patients with COPD aged 40-80 years who had a smoking history of at least 20 pack-years, recruited from six clinical sites and additional subsites in the USA between Nov 12, 2010, and April 21, 2015. Inclusion criteria for this analysis were SPIROMICS baseline visit data with complete blood cell counts and, in a subset, acceptable sputum counts. We stratified patients on the basis of blood and sputum eosinophil concentrations and compared their demographic characteristics, as well as results from questionnaires, clinical assessments, and quantitative CT (QCT). We also analysed whether blood eosinophil concentrations reliably predicted sputum eosinophil concentrations. This study is registered with ClinicalTrials.gov (NCT01969344). Of the 2737 patients recruited to SPIROMICS, 2499 patients were smokers and had available blood counts, and so were stratified by mean blood eosinophil count: 1262 patients with low (George Respiratory Questionnaire symptom scores (p=0·037), and increased wheezing (p=0·018), but no evidence of an association with COPD exacerbations (p=0·35) or the other indices of COPD severity, such as emphysema measured by CT density, COPD assessment test scores, Body-mass index, airflow Obstruction, Dyspnea, and Exercise index, or Global Initiative for Chronic Obstructive Lung Disease stage. Blood eosinophil counts showed a weak but significant association with sputum eosinophil counts

  18. Differential white blood cell count and type 2 diabetes: systematic review and meta-analysis of cross-sectional and prospective studies.

    Directory of Open Access Journals (Sweden)

    Effrossyni Gkrania-Klotsas

    2010-10-01

    Full Text Available Biological evidence suggests that inflammation might induce type 2 diabetes (T2D, and epidemiological studies have shown an association between higher white blood cell count (WBC and T2D. However, the association has not been systematically investigated.Studies were identified through computer-based and manual searches. Previously unreported studies were sought through correspondence. 20 studies were identified (8,647 T2D cases and 85,040 non-cases. Estimates of the association of WBC with T2D were combined using random effects meta-analysis; sources of heterogeneity as well as presence of publication bias were explored.The combined relative risk (RR comparing the top to bottom tertile of the WBC count was 1.61 (95% CI: 1.45; 1.79, p = 1.5*10(-18. Substantial heterogeneity was present (I(2 = 83%. For granulocytes the RR was 1.38 (95% CI: 1.17; 1.64, p = 1.5*10(-4, for lymphocytes 1.26 (95% CI: 1.02; 1.56, p = 0.029, and for monocytes 0.93 (95% CI: 0.68; 1.28, p = 0.67 comparing top to bottom tertile. In cross-sectional studies, RR was 1.74 (95% CI: 1.49; 2.02, p = 7.7*10(-13, while in cohort studies it was 1.48 (95% CI: 1.22; 1.79, p = 7.7*10(-5. We assessed the impact of confounding in EPIC-Norfolk study and found that the age and sex adjusted HR of 2.19 (95% CI: 1.74; 2.75 was attenuated to 1.82 (95% CI: 1.45; 2.29 after further accounting for smoking, T2D family history, physical activity, education, BMI and waist circumference.A raised WBC is associated with higher risk of T2D. The presence of publication bias and failure to control for all potential confounders in all studies means the observed association is likely an overestimate.

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  20. Mortality prediction to hospitalized patients with influenza pneumonia: PO2 /FiO2 combined lymphocyte count is the answer.

    Science.gov (United States)

    Shi, Shu Jing; Li, Hui; Liu, Meng; Liu, Ying Mei; Zhou, Fei; Liu, Bo; Qu, Jiu Xin; Cao, Bin

    2017-05-01

    Community-acquired pneumonia (CAP) severity scores perform well in predicting mortality of CAP patients, but their applicability in influenza pneumonia is powerless. The aim of our research was to test the efficiency of PO 2 /FiO 2 and CAP severity scores in predicting mortality and intensive care unit (ICU) admission with influenza pneumonia patients. We reviewed all patients with positive influenza virus RNA detection in Beijing Chao-Yang Hospital during the 2009-2014 influenza seasons. Outpatients, inpatients with no pneumonia and incomplete data were excluded. We used receiver operating characteristic curves (ROCs) to verify the accuracy of severity scores or indices as mortality predictors in the study patients. Among 170 hospitalized patients with influenza pneumonia, 30 (17.6%) died. Among those who were classified as low-risk (predicted mortality 0.1%-2.1%) by pneumonia severity index (PSI) or confusion, urea, respiratory rate, blood pressure, age ≥65 year (CURB-65), the actual mortality ranged from 5.9 to 22.1%. Multivariate logistic regression indicated that hypoxia (PO 2 /FiO 2  ≤ 250) and lymphopenia (peripheral blood lymphocyte count pneumonia confirmed a similar pattern and PO 2 /FiO 2 combined lymphocyte count was also the best predictor for predicting ICU admission. In conclusion, we found that PO 2 /FiO 2 combined lymphocyte count is simple and reliable predictor of hospitalized patients with influenza pneumonia in predicting mortality and ICU admission. When PO 2 /FiO 2  ≤ 250 or peripheral blood lymphocyte count pneumonia. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  1. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  2. Impact of donor- and collection-related variables on product quality in ex utero cord blood banking.

    Science.gov (United States)

    Askari, Sabeen; Miller, John; Chrysler, Gayl; McCullough, Jeffrey

    2005-02-01

    Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 x 10(7), and 5.2 x 10(6), respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks' gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  4. Four-Parameter white blood cell differential counting based on light scattering measurements

    NARCIS (Netherlands)

    Terstappen, Leonardus Wendelinus Mathias Marie; de Grooth, B.G.; Visscher, K.; Kouterik, F.A.; Greve, Jan

    1988-01-01

    Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinephilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped

  5. Mean Platelet Volume, Red Cell Distribution Width to Platelet Count Ratio, Globulin Platelet Index, and 16 Other Indirect Noninvasive Fibrosis Scores: How Much Do Routine Blood Tests Tell About Liver Fibrosis in Chronic Hepatitis C?

    Science.gov (United States)

    Thandassery, Ragesh B; Al Kaabi, Saad; Soofi, Madiha E; Mohiuddin, Syed A; John, Anil K; Al Mohannadi, Muneera; Al Ejji, Khalid; Yakoob, Rafie; Derbala, Moutaz F; Wani, Hamidullah; Sharma, Manik; Al Dweik, Nazeeh; Butt, Mohammed T; Kamel, Yasser M; Sultan, Khaleel; Pasic, Fuad; Singh, Rajvir

    2016-07-01

    Many indirect noninvasive scores to predict liver fibrosis are calculated from routine blood investigations. Only limited studies have compared their efficacy head to head. We aimed to compare these scores with liver biopsy fibrosis stages in patients with chronic hepatitis C. From blood investigations of 1602 patients with chronic hepatitis C who underwent a liver biopsy before initiation of antiviral treatment, 19 simple noninvasive scores were calculated. The area under the receiver operating characteristic curves and diagnostic accuracy of each of these scores were calculated (with reference to the Scheuer staging) and compared. The mean age of the patients was 41.8±9.6 years (1365 men). The most common genotype was genotype 4 (65.6%). Significant fibrosis, advanced fibrosis, and cirrhosis were seen in 65.1%, 25.6, and 6.6% of patients, respectively. All the scores except the aspartate transaminase (AST) alanine transaminase ratio, Pohl score, mean platelet volume, fibro-alpha, and red cell distribution width to platelet count ratio index showed high predictive accuracy for the stages of fibrosis. King's score (cutoff, 17.5) showed the highest predictive accuracy for significant and advanced fibrosis. King's score, Göteborg university cirrhosis index, APRI (the AST/platelet count ratio index), and Fibrosis-4 (FIB-4) had the highest predictive accuracy for cirrhosis, with the APRI (cutoff, 2) and FIB-4 (cutoff, 3.25) showing the highest diagnostic accuracy.We derived the study score 8.5 - 0.2(albumin, g/dL) +0.01(AST, IU/L) -0.02(platelet count, 10/L), which at a cutoff of >4.7 had a predictive accuracy of 0.868 (95% confidence interval, 0.833-0.904) for cirrhosis. King's score for significant and advanced fibrosis and the APRI or FIB-4 score for cirrhosis could be the best simple indirect noninvasive scores.

  6. Modelling T4 cell count as a marker of HIV progression in the absence of any defence mechanism

    Directory of Open Access Journals (Sweden)

    VSS Yadavalli

    2010-12-01

    Full Text Available The T4 cell count, which is considered one of the markers of disease progression in an HIV infected individual, is modelled in this paper. The World Health Organisation has recently advocated that countries encourage HIV infected individuals to commence antiretroviral treatments once their T4 cell count drops below 350 cells per ml of blood (this threshold was formerly 200 cells per ml of blood. This recommendation is made because when the T4 cell count is low, the T4 cells are unable to mount an effective immune response against antigens and any such foreign matters in the body, and consequently the individual becomes susceptible to opportunistic infections and lymphomas. A stochastic catastrophe model is developed in this paper to obtain the mean, variance and covariance of the uninfected, infected and lysed T4 cells. The amount of toxin produced in an HIV infected person from the time of infection to a later time may also be obtained from the model. Numerical illustrations of the correlation structures between uninfected and infected T4 cells, and between the infected and lysed T4 cells are also presented.

  7. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients

    Directory of Open Access Journals (Sweden)

    Tina Dadu

    2013-01-01

    Full Text Available Background: There are several methods for counting platelets, of which the international flow reference method (IRM is considered to be the gold standard. We compared the platelet count given by this method to the count given by automated analyzers using other methods, such as optical fluorescence and impedance. Aims: The aim of this study is to compare the platelet counts obtained by Sysmex XE 2100 by Impedance (Sysmex-I, optical florescence (Sysmex-O and reported (Sysmex-R based on the switching algorithm and LH-750 by Impedance (LH-750 with the IRM in thrombocytopenic blood samples. To calculate the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of various technologies at the clinically relevant transfusion thresholds of 10 × 10 9 /l and 20 × 10 9 /l. Materials and Methods: A total of 118 blood samples with platelet count of <50 × 10 9 /l were selected for the study. Platelet counts of all samples were analyzed by all methods using the Sysmex analyzer, LH-750 and IRM in parallel within 6 h of collection. Statistical Analysis Used: Pearson correlation, bland Altman analysis, sensitivity and specificity, PPV and NPV. Results and Conclusions: Sysmex-R had the least Bias and 95% limits of agreement (95%LA range and thus correlated best with IRM values. LH-750 had a higher Bias compared to Sysmex-O and Sysmex-R, but a strikingly similar 95% LA ensures similar results in all three methods. In fact, in the oncology subset, it had the narrowest 95% LA, which made it the best performer in this subgroup. Of the three Sysmex results, Sysmex-I had the highest bias, widest 95% LA and highest potential risk of over transfusion. Hence, Sysmex-R and LH-750 were found to be reliable tools for estimation of platelet count in thrombocytopenic patients.

  8. Quantitative clinical uptake measurements using conjugate counting

    International Nuclear Information System (INIS)

    Lathrop, K.A.; Bartlett, R.D.; Chen, C.T.; Chou, J.S.; Faulhaber, P.F.; Harper, P.V.; Stark, V.J.

    1986-01-01

    While the use of conjugate counting for determination of organ uptake in human subjects has been extensively described, in the present study the determination of the organ uptake of ortho-iodohippurate presented several opportunities for validation of the in vivo counting data. Ortho-iodohippurate is distributed in the extracellular space, is largely extracted on each pass through the kidneys, and is not significantly deiodinated in vivo. Thus, the kidney uptake rate should be proportional to the blood level, the appearance rate of activity in the bladder is equal to the disappearance rate from the kidneys, and direct measurement of activity in the urine after voiding provides an internal standard for imaging measurements of bladder activity. Since the activity levels in the kidneys, bladder, and remainder of the body changed fairly rapidly, especially in the first 20 to 30 minutes following injection, posterior images of the trunk including kidneys and bladder were obtained continuously using a gamma camera fitted with a diverging collimator for 30 minutes and then at intervals for several hours. Simultaneous conjugate counting determinations were made using a whole body scanning system previously described at these meetings. Imaging data corrected for decay and adjacent background were fitted by least squares methods to curves representing a sum of exponentials, and the curves were normalized to the conjugate uptake measurements. The uptake curves of the kidneys and bladder matched well with the direct measurements of the urinary excretion. Data were collected in 16 normal subjects, and the estimated absorbed dose was calculated for the kidneys, the bladder and the remainder of the body for seven radioisotopes of iodine. 4 references, 6 figures, 2 tables

  9. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  10. Blood Changes after Splenectomy in Portal Hypertension. The ...

    African Journals Online (AJOL)

    Background: Splenectomy is a frequently performed operation for patients with portal hypertension and hypersplenism in areas endemic for schistosomiasis. Reactive thrombocytosis (RT) has been described following splenectomy. Nevertheless, data are lacking on the long term changes of platelet count and other blood ...

  11. Frequencies of micronuclei in lymphocytes and complete blood picture of radiation worker at Al-Twuathia Site Iraq

    International Nuclear Information System (INIS)

    Amel, J.M.; Abdulsahib, K. A.; Abdullah, A.G.; Haider, Y.L.; Ali, H.F.

    2012-12-01

    The present study aims to use the frequency of micronuclei in lymphocyte and complete blood picture as a bio markers for detection of the effects of the low radiation doses in to decommissioning to radioactive contamination (Lama and Geo- Pilot) as a result of work, during January 2009 to November 2011 present study including collected 113 blood samples, including (103 male and female) aged (25 - 65) year for the exam of compete blood picture analysis, included 69 blood samples as first time before work in Al-Twuathia site, 22 blood samples as a second and third exam. While the cytogenetic analysis including 78 male blood samples aged (35 - 63) year, included 30 blood samples as first time be for work in Al-Twuathia site, 30 blood samples as a second exam and 18 blood samples as third exam, as well as 50 blood samples which are not smokers and alcohol as control group which including (40 male and 10 female) aged (30 - 55 year). Three cytogenetic parameter were employed such as frequency of micronuclei, mitotic index an nuclear and nuclear division index, which used for detection of biological effects of ionizing radiation. Also the current study included the detection of the effect of radiation in complete blood picture analysis of workers at Al-Tuwaitha site, which included (Hb, PCV, WBC count, differential count of WBCs, platelets count of WBCs, platelets count and ESR). From the study no significant differences in the rate of micronuclei and division index of workers in the first and second examination compared with the group of workers in the third exam, while observed a significant increase slightly at level (P <0.05) in these rates compared with the control group, as well as were recorded no significant differences in the rate of mitotic index for workers compared with the control group. Also, found no significant difference in complete blood picture analysis for workers compared with the control group. In conclusion, the significant slightly increase at the

  12. Radioimmunoanalysis of delta-9-THC in blood by means of an 125I tracer

    International Nuclear Information System (INIS)

    Owens, S.M.; McBay, A.J.; Reisner, H.M.

    1982-01-01

    A radioimmunoassay for delta-9-THC in plasma, whole blood, or hemolyzed blood specimens has been presented. Samples and standards were diluted with methanol and centrifuged. An aliquot of the supernatant fluid was incubated with RIA buffer, 125 I-labeled delta-8-THC and rabbit anti-THC serum. Solid phase goat anti-rabbit immunoglobulins were added to separate bound from free THC. After centrifugation the supernatant fluid was aspirated and the radioactivity of the precipitate was counted in a gamma counter. The concentration of THC was calculated from a standard curve using the logit-log transformation of the average counts of duplicate tubes. The assay had several advantages. Methanol dilution gave better results than direct analysis. The 125 I-labeled THC had high specific activity and could be counted in a gamma counter. The immunological separation of antibody-bound THC from free THC was better than separation techniques using ammonium sulfate and activated charcoal. THC was determined in 0.1 ml of sample with a sensitivity of 1.5 ng/ml in plasma and 3.0 ng/ml in hemolyzed blood

  13. Protective effect of curcumin on experimentally induced arthritic rats: detailed histopathological study of the joints and white blood cell count

    Science.gov (United States)

    Kamarudin, Taty Anna; Othman, Faizah; Mohd Ramli, Elvy Suhana; Md Isa, Nurismah; Das, Srijit

    2012-01-01

    Curcuma longa (turmeric) rhizomes contains curcumin, an active compound which possesses anti-inflammatory effects. Collagen-induced arthritis (CIA) is an accepted experimental animal model of rheumatoid arthritis. The present study aimed to observe the histological changes in the joints of experimental arthritic rats treated with curcumin. Twenty four male Sprague-Dawley (approximately 7 weeks-old) rats were randomly divided into four groups. Three groups were immunized with 150 µg collagen. All rats with established CIA, with arthritis scores exceeding 1, were orally treated with betamethasone (0.5 mg/ml/kg body weight), curcumin (110 mg/ml/kg body weight) or olive oil (1.0 ml/kg body weight) daily, for two weeks. One remaining group was kept as normal control. Treatment with 110 mg/ml/kg curcumin showed significant mean differences in the average white blood cell (WBC) count (pPannus formation scores showed that curcumin supplementation successfully suppressed the pannus formation process that occurred in the articular cartilage of the CIA joints. The mean difference for histological scores for the curcumin group was insignificant compared to the betamethasone treated group. It is concluded that supplementation of curcumin has protective effect on the histopathological and degenerative changes in the joints of CIA rats which was at par with betamethasone. PMID:27366139

  14. Protective effect of curcumin on experimentally induced arthritic rats: detailed histopathological study of the joints and white blood cell count.

    Science.gov (United States)

    Kamarudin, Taty Anna; Othman, Faizah; Mohd Ramli, Elvy Suhana; Md Isa, Nurismah; Das, Srijit

    2012-01-01

    Curcuma longa (turmeric) rhizomes contains curcumin, an active compound which possesses anti-inflammatory effects. Collagen-induced arthritis (CIA) is an accepted experimental animal model of rheumatoid arthritis. The present study aimed to observe the histological changes in the joints of experimental arthritic rats treated with curcumin. Twenty four male Sprague-Dawley (approximately 7 weeks-old) rats were randomly divided into four groups. Three groups were immunized with 150 µg collagen. All rats with established CIA, with arthritis scores exceeding 1, were orally treated with betamethasone (0.5 mg/ml/kg body weight), curcumin (110 mg/ml/kg body weight) or olive oil (1.0 ml/kg body weight) daily, for two weeks. One remaining group was kept as normal control. Treatment with 110 mg/ml/kg curcumin showed significant mean differences in the average white blood cell (WBC) count (pcurcumin supplementation successfully suppressed the pannus formation process that occurred in the articular cartilage of the CIA joints. The mean difference for histological scores for the curcumin group was insignificant compared to the betamethasone treated group. It is concluded that supplementation of curcumin has protective effect on the histopathological and degenerative changes in the joints of CIA rats which was at par with betamethasone.

  15. Effect of a short period whole body vibration with 10 Hz on blood ...

    African Journals Online (AJOL)

    Samples of whole blood were drawn for biochemical analysis of the concentration of total cholesterol, triglycerides, HDL, LDL, VLDL, glucose, CPK, albumin, alkaline phosphates, TGP, TGO, γGT, lipase, amylase, urea and creatinine. Results: White blood cell count and a platelet-hemogram were also performed. Significant ...

  16. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  17. TasselNet: counting maize tassels in the wild via local counts regression network.

    Science.gov (United States)

    Lu, Hao; Cao, Zhiguo; Xiao, Yang; Zhuang, Bohan; Shen, Chunhua

    2017-01-01

    Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting ( MTC ) dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large margins and achieves the overall best counting

  18. TasselNet: counting maize tassels in the wild via local counts regression network

    Directory of Open Access Journals (Sweden)

    Hao Lu

    2017-11-01

    Full Text Available Abstract Background Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. Results This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting (MTC dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large

  19. Evaluation of plasma eosinophil count and mean platelet volume in patients with coronary slow flow

    Directory of Open Access Journals (Sweden)

    Mehmet Demir

    2014-01-01

    Full Text Available OBJECTIVE: The pathophysiology of coronary slow flow has not been clearly defined, although multiple abnormalities including arteritis, endothelial dysfunction, and atherothrombosis, have been reported. It is known that eosinophils play an important role in inflammation, endothelial dysfunction, and thrombosis. We aimed to compare the eosinophil counts of coronary slow flow patients versus healthy controls. METHODS: This study included 50 coronary slow flow patients (19 males, mean age 65.6±13.7 years and 30 healthy controls (10 males, mean age 57.86±11.6 years. These participants were evaluated using concurrent routine biochemical tests as well as neutrophil, lymphocyte, and eosinophil counts and mean platelet volume (MPV, which were obtained from the whole blood count. These parameters were compared between groups. RESULTS: The baseline characteristics of the study groups were comparable. The coronary slow flow patients had a higher mean platelet volume and eosinophil count than the control group (8.38±0.86 vs 6.28±1.6 fL and 0.31±0.42 vs 0.09±0.05; p<0.001 and 0.008, respectively. CONCLUSION: Our study demonstrated a relationship between eosinophil count and MPV in patients with coronary slow flow.

  20. Social rank influences the distribution of blood leukocyte subsets in female growing pigs

    DEFF Research Database (Denmark)

    Hjarvard, Bodil Margrethe; Larsen, Ole Næsbye; Juul-Madsen, Helle Risdahl

    2010-01-01

    reduced growth as compared to DOM pigs confirming their lower social status. Blood was sampled for immunological assessments immediately before grouping the pigs and again after the 5 weeks of social housing. White Blood Cell (WBC) counts, percentage of CD4 positive cells (CD4+), percentage of CD8...

  1. BLOOD SELENIUM CONCENTRATION AFFECT MASTITIS AND MILK QUALITY IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Davidov Ivana

    2013-02-01

    Full Text Available Milk quality is usually defined in terms of mastitis. Milk with somatic cell count low then 400.000/ml and visibly normal (no clots is considered high quality. Thirty Holstein cows were used in the study to determine affect blood serum selenium concentration on mastitis and milk quality. Cows received ad libitum access to potable water and daily 0.3 mg/kg inorganic selenium supplementation in food. Blood and milk samples were taken at first and sixth lactating month. Mean selenium blood serum concentrations were found to be lower within first lactating month, and then increased in the sixth lactating month. Average somatic cell count at first lactating month was 450.000/ml of milk and at sixth lactating month was 355.000/ml. On the basis of these results it can be conclude that selenium have importance in proper functioning of the mammary glands of cows, and in reducing mastitis and in improving milk quality.

  2. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  3. Spleen size changes in children with homozygous β-thalassaemia in relation to blood transfusion

    International Nuclear Information System (INIS)

    Karpathios, Th.; Antypas, A.; Dimitriou, P.; Nicolaidou, P.; Fretzayas, A.; Thomaidis, Th.; Matsaniotis, N.

    1982-01-01

    18 thalassaemic children, aged 3.5 to 13 years comprise our clinical material. In 14 of them, clinically elicited spleen markings, haematocrit, blood platelet count and red cell morphology were studied daily for a whole period between 2 transfusions. In 10 patients considerable changes in spleen size were noticed. According to our clinical observations the spleen size starts decreasing 1 to 3 d after blood transfusion up to the 10th posttransfusion day fluctuating thereafter to reach its maximum size again prior to the next blood transfusion. The decrease of spleen size was followed by an increase of haematocrit and blood platelet count and vice versa. 4 additional children were studied clinically only twice: prior to and 7 to 10 d after blood transfusion. A definite decrease of the spleen size following blood transfusion was observed. Spleen and liver sup(99m)Tc-sulfur colloid uptake was studied in 10 of the above children prior to and 7 to 10 d after blood transfusion. Statistically significant post-transfusion increase of the spleen uptake was demonstrated. Our findings suggest that (a) splenic size is relevant to blood volume sequestrated int this organ, (b) splenic radioactive uptake increases with its post-transfusion reductin in size. (author)

  4. Computed aided system for separation and classification of the abnormal erythrocytes in human blood

    Science.gov (United States)

    Wąsowicz, Michał; Grochowski, Michał; Kulka, Marek; Mikołajczyk, Agnieszka; Ficek, Mateusz; Karpieńko, Katarzyna; Cićkiewicz, Maciej

    2017-12-01

    The human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified diamonds and oxidation modified. The blood was put under an impact of two diamond concentrations: 20μl and 100μl. The amount of abnormal cells increased with time. The percentage of echinocytes as a result of interaction with nanodiamonds in various time intervals for individual specimens was scarce. The impact of the two diamond types had no clinical importance on red blood cells. It is supposed that as a result of longlasting exposure a dehydratation of red cells takes place, because of the function of the cells. The analysis of an influence of nanodiamond particles on blood elements was supported by computer system designed for automatic counting and classification of the Red Blood Cells (RBC). The system utilizes advanced image processing methods for RBCs separation and counting and Eigenfaces method coupled with the neural networks for RBCs classification into normal and abnormal cells purposes.

  5. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  6. Dataset of longitudinal analysis of tear cytokine levels, CD4, CD8 counts and HIV viral load in dry eye patients with HIV infection

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Balne

    2017-04-01

    Full Text Available The data presented in this article shows the longitudinal analysis of tear fluid cytokine profiles, blood CD4 and CD8 counts and HIV viral load in 34 dry eye patients with HIV infection during the HAART therapy. Clinical samples were collected from HIV patients with dry eye disease at the time of presentation to the clinic (visit 1, three months (visit 2 and 6 months (visit 3 after the presentation. At each time point tear samples were evaluated for 41 cytokines using Luminex bead based multiplex assay and blood samples were tested for HIV viral load and CD4 and CD8 counts.

  7. Colour measurement and white blood cell recognition

    CERN Document Server

    Gelsema, E S

    1972-01-01

    As a part of a collaboration with NEMCH aimed at the automation of the differential white blood cell count, studies have been made of the different possibilities for using colour to help in the recognition process. Results are presented comparing data obtained with a microspectrophotometer and with a simulated three-colour scanner.

  8. Characterization of blood donors with high haemoglobin concentration

    DEFF Research Database (Denmark)

    Magnussen, K; Hasselbalch, H C; Ullum, H

    2013-01-01

    Background and Objectives  The literature contains little on the prevalence and causes of high predonation haemoglobin levels among blood donors. This study aimed to characterize and develop an algorithm to manage would-be donors with polycythaemia. Materials and Methods  Between November 2009...... and November 2011, we offered haematology consultations to blood donors with repeated haemoglobin concentration (Hb) above the WHO limit for polycythaemia vera (PV) (10·2 and 11·5 mm/16·5 and 18·5 g/dl for women and men, respectively). Investigation of such donors included Hb, haematocrit, mean cell volume......, erythropoietin, ferritin, platelet count and leucocyte count, JAK2 V617 and JAK2 exon12 analysis, as well as other routine measurements. Results  Among 46 such donors, 39 had a history of smoking, which contributes to erythrocytosis. Two had PV, five had severe hypertension, one of them because of renal artery...

  9. Quantitative assessment of gastrointestinal blood loss with anti-inflammatory drugs

    International Nuclear Information System (INIS)

    Dahanukar, S.A.; Sheth, U.K.; Bhiwankar, N.T.; Ramnath, S.R.; Mehta, B.C.; Katoch, D.S.

    1980-01-01

    A comparative study of gastrointestinal blood loss caused by aspirin, flurbiprofen and RH-8 was carried out in 24 normal volunteers in whom erythrocytes were labelled with radioactive chromium i.e. Cr 51 . Blood loss was estimated by counting radio-activity in vitro taking total amount of faeces. The method used was independent of distribution of radio-activity in the faeces, which does not require homogenization. Significant increase in blood loss occurred with aspirin, flurbiprofen and RH-8; only the difference between RH-8 and flurbiprofen group is significant. (auth.)

  10. Understanding Blood Counts

    Science.gov (United States)

    ... Certain drugs Infection Chemotherapy and other medicines Malaria Alcoholism AIDS Lupus Enlarged spleen Pregnancy Idiopathic thrombocytopenic purpura Thrombotic thrombocytopenic purpura Hemolytic uremic ...

  11. The absolute counting of red cell-derived microparticles with red cell bead by flow rate based assay.

    Science.gov (United States)

    Nantakomol, Duangdao; Imwong, Malika; Soontarawirat, Ingfar; Kotjanya, Duangporn; Khakhai, Chulalak; Ohashi, Jun; Nuchnoi, Pornlada

    2009-05-01

    Activation of red blood cell is associated with the formation of red cell-derived microparticles (RMPs). Analysis of circulating RMPs is becoming more refined and clinically useful. A quantitative Trucount tube method is the conventional method uses for quantitating RMPs. In this study, we validated a quantitative method called "flow rate based assay using red cell bead (FCB)" to measure circulating RMPs in the peripheral blood of healthy subjects. Citrated blood samples collected from 30 cases of healthy subjects were determined the RMPs count by using double labeling of annexin V-FITC and anti-glycophorin A-PE. The absolute RMPs numbers were measured by FCB, and the results were compared with the Trucount or with flow rate based calibration (FR). Statistical correlation and agreement were analyzed using linear regression and Bland-Altman analysis. There was no significant difference in the absolute number of RMPs quantitated by FCB when compared with those two reference methods including the Trucount tube and FR method. The absolute RMPs count obtained from FCB method was highly correlated with those obtained from Trucount tube (r(2) = 0.98, mean bias 4 cell/microl, limit of agreement [LOA] -20.3 to 28.3 cell/microl), and FR method (r(2) = 1, mean bias 10.3 cell/microl, and LOA -5.5 to 26.2 cell/microl). This study demonstrates that FCB is suitable and more affordable for RMPs quantitation in the clinical samples. This method is a low cost and interchangeable to latex bead-based method for generating the absolute counts in the resource-limited areas. (c) 2008 Clinical Cytometry Society.

  12. Blood eosinophil levels as a biomarker in COPD.

    Science.gov (United States)

    Brusselle, Guy; Pavord, Ian D; Landis, Sarah; Pascoe, Steven; Lettis, Sally; Morjaria, Nikhil; Barnes, Neil; Hilton, Emma

    2018-05-01

    Chronic obstructive pulmonary disease (COPD) is a heterogeneous disorder and patients respond differently to treatment. Blood eosinophils are a potential biomarker to stratify patient subsets for COPD therapy. We reviewed the value of blood eosinophils in predicting exacerbation risk and response to corticosteroid treatment in the available literature (PubMed articles in English; keywords: "COPD" and "eosinophil"; published prior to May 2017). Overall, clinical data suggest that in patients with a history of COPD exacerbations, a higher blood eosinophil count predicts an increased risk of future exacerbations and is associated with improved response to treatment with inhaled corticosteroids (in combination with long-acting bronchodilator[s]). Blood eosinophils are therefore a promising biomarker for phenotyping patients with COPD, although prospective studies are needed to assess blood eosinophils as a biomarker of corticosteroid response for this. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Early intraoperative blood collection does not affect complete blood counts, von Willebrand factor or factor VIII levels in normal children.

    Science.gov (United States)

    Darwish, Hanni; Mundell, Gillianne; Engen, Dale; Lillicrap, David; Silva, Mariana; James, Paula

    2011-01-01

    Obtaining blood from children for research studies can be difficult, particularly for controls. One solution is to obtain samples during elective surgery; however, consideration must be given to the potential effects of the timing of phlebotomy. Ten children were recruited and phlebotomy was carried out during a preoperative clinic visit and intraoperatively immediately after the induction of anesthesia but before the start of surgery. CBCs, VWF, and FVIII levels were measured at both time points and no significant differences were seen. This negative result may be beneficial to pediatric research by suggesting that early intraoperative blood collection for controls does not affect the results.

  14. Complete blood count risk score and its components, including RDW, are associated with mortality in the JUPITER trial.

    Science.gov (United States)

    Horne, Benjamin D; Anderson, Jeffrey L; Muhlestein, Joseph B; Ridker, Paul M; Paynter, Nina P

    2015-04-01

    Previously, we showed that sex-specific complete blood count (CBC) risk scores strongly predicted risk of all-cause mortality in multiple sets of general medical patients. This study evaluated the CBC risk score in an independent, well-studied international primary risk population of lower-risk individuals initially free from cardiovascular (CV) disease. Observational secondary analysis of a randomized trial population. The previously derived and validated CBC score was evaluated for association with all-cause mortality among CV disease-free females (n = 6568) and males (n = 10,629) enrolled for up to 5 years in the Justification for the Use of Statins in Prevention: an Intervention Trial Evaluating Rosuvastatin (JUPITER) trial. Associations of the CBC score with CV mortality and with major CV disease were also tested. The CBC score predicted all-cause mortality, with univariable hazard ratio (HR) 4.83 (95% CI 3.70-6.31) for the third CBC score tertile vs. the first tertile, and HR 2.31 (CI 1.75-3.05) for the second tertile (p trend JUPITER endpoint (p trend = 0.015). c-statistics for mortality were 0.729 among all, and 0.722 and 0.750 for females and males, respectively. The CBC risk score was strongly associated with all-cause mortality among JUPITER trial participants and had good discrimination. It also predicted CV-specific outcomes. This CBC score may be useful in identifying cardiac disease-free individuals at increased risk of mortality. © The European Society of Cardiology 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  16. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  17. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  18. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  19. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  20. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  1. Effect of an Arctium lappa (burdock) extract on the labeling of blood constituents with technetium-99m and on the morphology of the red blood cells

    International Nuclear Information System (INIS)

    Neves, Rosane de Figueiredo; Rebello, Bernardo Machado; Medeiros, Aldo da Cunha; Moreno, Silvana Ramos Farias; Fonseca, Adenilson de Souza da; Caldas, Luiz Querino de Araujo; Bernardo-Filho, Mario

    2007-01-01

    Arctium lappa (burdock) has been used to treat inflammatory processes. Blood constituents labeled with technetium-99m ( 99m Tc) have been utilized in nuclear medicine. It was evaluated the influence of a burdock extract on the labeling of blood constituents with 99m Tc and on the morphometry of red blood cells. Blood samples from Wistar rats were incubated with burdock extract and the radiolabeling procedure was carried out. Plasma and blood cells, soluble and insoluble fractions of plasma and blood cells were separated. The radioactivity in each fraction was counted and the percentages of radioactivity (%ATI) were determined. Morphology and morphometric (perimeter/area ratio) measurements of red blood cells (RBC) were performed. The incubation with burdock extract significantly (p 99m Tc obtained in this study. (author)

  2. Eosinophilia in routine blood samples as a biomarker for solid tumor development

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, V.D.; Hasselbalch, H.C.

    2014-01-01

    eosinophilia in routine blood samples as a potential biomarker of solid tumor development in a prospective design. MATERIAL AND METHODS: From the Copenhagen Primary Care Differential Count (CopDiff) Database, we identified 356 196 individuals with at least one differential cell count (DIFF) encompassing...... was increased with mild eosinophilia [OR 1.93 (CI 1.29-2.89), p = 0.0013]. No associations with eosinophilia were observed for the remaining solid cancers. CONCLUSION: We demonstrate that eosinophilia in routine blood samples associates with an increased risk of bladder cancer. Our data emphasize...... that additional preclinical studies are needed in order to shed further light on the role of eosinophils in carcinogenesis, where it is still unknown whether the cells contribute to tumor immune surveillance or neoplastic evolution....

  3. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  4. Thrombocyte counts in malaria patients at East Kalimantan

    Science.gov (United States)

    Siagian, L. R. D.; Asfirizal, V.; Toruan, V. D. L.; Hasanah, N.

    2018-04-01

    Malaria still becoming a serious health problem in Indonesia. Beside disorders of erythrocytes, there are some data that Plasmodium caused the other blood cells like leukocyte and thrombocyte. In malaria, changes of thrombocyte is thrombocytopenia that would be a complication from malaria vivax or malaria falciparum. The aim of this study is to know the thrombocyte count of malaria patients in East Kalimantan. Design of this study is descriptic retrospective from medical record’s data from 2011-2016 in 7 hospitals (AW Syahranie at Samarinda, Kanudjoso at Balikpapan, Penajam Paser Utara at Panajam, AM Parikesit at Tenggarong, Taman Husada at Bontang, Kudungga at Sangata and Abdul Rivai at Tanjung Redeb. We collected the data from June-August 2017. There are 1041 malaria patients with male and female respectively 88.2% and 11.2%. The etiology of malaria were Plasmodium falciparum, Plasmodium vivax and mixed infection (P.f and P.v) respectively 62.6%, 38% and 6.1%. We found thrombocyte count was normal, decrease and increase respectively 11%, 85% and 1.7%. The degree of thrombocytopenia in malaria patients were mild (100.000-150.000/µl) 31.8%, moderate (50.000-100.000/µL) 45.6% and severe (malaria patients at East Kalimantan was thrombocytopenia with moderate degree of thrombocytopenia.

  5. Long term observation on absolute lymphocyte counts in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Oesterle, S.N.; Norman, J.E. Jr.

    1980-01-01

    Total peripheral blood lymphocytes were evaluated by age and exposure status in the Adult Health Study population during three examination cycles between 1958 and 1972. No radiation effect was observed, but a significant drop in the absolute lymphocyte counts of those aged 70 years and over and a corresponding maximum for persons aged 50 - 59 was observed. (author)

  6. [Regional blood flow and bone uptake of methylene-diphosphonate-technetium-99m].

    Science.gov (United States)

    Vattimo, A; Martini, G; Pisani, M

    1983-05-30

    Sudeck's atrophy of the foot is an acute, patchy osteoporosis that, on bone scan, shows an increase in both bone blood flow and local bone uptake of bone-seeking radionuclides. The purpose of this study was to evaluate the relationship between bone uptake of 99mTc-MDP and local bone blood flow. In some patients with Sudeck's atrophy of one foot we measured local bone blood flow and bone uptake of 99mTc-MDP. External counting of radioactivity, with a count-rate of 1 second was performed for 60 minutes after i.v. injection of a known dose of 99mTc-MDP in some patients with Sudeck's atrophy of the foot. The regions of interest (ROI) were selected on the basis of a bone scan performed 24 hours earlier. We assumed that the data recorded during the first seconds (7-10) reflect local blood flow and the data at 60 minutes reflect the bone uptake. The ratio between the local blood flow in the involved and healthy foot was higher than the local bone uptake ratio. The ratio between bone uptake and local bone blood flow was higher in the normal foot than in the affected one. These results suggest that the bone avidity for bone-seeking radionuclides is lower in Sudeck's atrophy than in normal bone.

  7. Effects of fenoprofen on the labeling of blood constituents with technetium-99m, the morphology of red blood cells and the plasmid

    International Nuclear Information System (INIS)

    Pereira, Marcia de Oliveira; Rocha, Gabrielle de Souza; Lombardi, Simone dos Santos; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario; Pereira, Mario Jose; Geller, Mauro

    2008-01-01

    The aim of this work was to evaluate the effect of fenoprofen on the labeling of blood constituents with technetium- 99m, on the morphology of red blood cells and on the plasmid DNA. Blood samples from Wistar rats were incubated with fenoprofen and the assay of labeling of blood constituents with technetium-99m ( 99m Tc) was performed. Blood cells, plasma, soluble and insoluble fractions of blood cells and plasma were separated. The radioactivity in each fraction was counted and percentage of incorporated radioactivity (%ATI) was determined. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphology of the red blood cells (RBC) was evaluated. Plasmid (pBSK) was incubated with fenoprofen with stannous chloride, and agarose gel electrophoresis procedure was carried out to evaluate genotoxic and the protection of this drug against stannous chloride effect on DNA. In conclusion, under the conditions used in this work, our data suggest that fenoprofen would not affect the fixation of the 99m Tc on the blood constituents, alter the RBC membrane and present genotoxic and redox effects. (author)

  8. The Influence of High Iodine Intake on Chosen Blood Parameters of Sheep

    Directory of Open Access Journals (Sweden)

    Hana Dušová

    2014-01-01

    Full Text Available The objective of the study was to evaluate the influence of high iodine intake in ewes on haematological and biochemical parameters of the blood of ewes and their lambs. Twelve pregnant ewes of the Sumava sheep breed and their newborn lambs were included in the experiment. Control group (A consisted of 6 ewes with 7 lambs and experimental group (B comprised 6 ewes with 6 lambs. The feed ration was enriched with calcium iodate by addition of 3 and 5 mg/kg in group A and group B, respectively. The studied parameters in ewes and lambs were haematocrit value, red blood cell count and haemoglobin concentration in blood, concentration of urea and total proteins, and alkaline phosphatase activity in blood plasma. No differences were found out in haematocrit value, red blood cell count, concentration of haemoglobin and total proteins between groups of ewes A and B with their lambs. Urea concentration and alkaline phosphatase activity were higher in ewes of group B and their lambs during the entire experimental period. An increase in the values of urea and alkaline phosphatase in the group of ewes and lambs with higher iodine intake indicates a potential risk of high iodine intake associated with changes in the thyroid activity in ewes and their lambs.

  9. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  10. Numerical study on the complete blood cell sorting using particle tracing and dielectrophoresis in a microfluidic device

    Science.gov (United States)

    Ali, Haider; Park, Cheol Woo

    2016-11-01

    In this study, a numerical model of a microfluidic device with particle tracing and dielectrophoresis field-flow fractionation was employed to perform a complete and continuous blood cell sorting. A low voltage was applied to electrodes to separate the red blood cells, white blood cells, and platelets based on their cell size. Blood cell sorting and counting were performed by evaluating the cell trajectories, displacements, residence times, and recovery rates in the device. A novel numerical technique was used to count the number of separated blood cells by estimating the displacement and residence time of the cells in a microfluidic device. For successful blood cell sorting, the value of cells displacement must be approximately equal to or higher than the corresponding maximum streamwise distance. The study also proposed different outlet designs to improve blood cell separation. The basic outlet design resulted in a higher cells recovery rate than the other outlets design. The recovery rate decreased as the number of inlet cells and flow rates increased because of the high particle-particle interactions and collisions with walls. The particle-particle interactions significantly affect blood cell sorting and must therefore be considered in future work.

  11. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  12. Prognostic Significance of Blood Transfusion in Newly Diagnosed Multiple Myeloma Patients without Autologous Hematopoietic Stem Cell Transplantation

    Science.gov (United States)

    Fan, Liping; Fu, Danhui; Zhang, Jinping; Wang, Qingqing; Ye, Yamei; Xie, Qianling

    2017-01-01

    The aim of this study was to evaluate whether blood transfusions affect overall survival (OS) and progression-free survival (PFS) in newly diagnosed multiple myeloma (MM) patients without hematopoietic stem cell transplantation. A total of 181 patients were enrolled and divided into two groups: 68 patients in the transfused group and 113 patients in the nontransfused group. Statistical analyses showed that there were significant differences in ECOG scoring, Ig isotype, platelet (Plt) counts, hemoglobin (Hb) level, serum creatinine (Scr) level, and β2-microglobulin (β2-MG) level between the two groups. Univariate analyses showed that higher International Staging System staging, Plt counts blood transfusion was associated with PFS but not OS in MM patients. Multivariate analyses showed that blood transfusion was not an independent factor for PFS in MM patients. Our preliminary results suggested that newly diagnosed MM patients may benefit from a liberal blood transfusion strategy, since blood transfusion is not an independent impact factor for survival. PMID:28567420

  13. Rapid white blood cell detection for peritonitis diagnosis

    Science.gov (United States)

    Wu, Tsung-Feng; Mei, Zhe; Chiu, Yu-Jui; Cho, Sung Hwan; Lo, Yu-Hwa

    2013-03-01

    A point-of-care and home-care lab-on-a-chip (LoC) system that integrates a microfluidic spiral device as a concentrator with an optical-coding device as a cell enumerator is demonstrated. The LoC system enumerates white blood cells from dialysis effluent of patients receiving peritoneal dialysis. The preliminary results show that the white blood cell counts from our system agree well with the results from commercial flow cytometers. The LoC system can potentially bring significant benefits to end stage renal disease (ESRD) patients that are on peritoneal dialysis (PD).

  14. Function and platelet count in thrombocyte concentrate (TC during the storage

    Directory of Open Access Journals (Sweden)

    Elida Marpaung

    2016-01-01

    Full Text Available AbstrakLatar belakang: Evaluasi terhadap pemberian transfusi belum dilakukan secara optimal baik di hulumaupun di hilir. Tujuan penelitian ini untuk mengetahui pengaruh waktu penyimpanan terhadap perubahanpH, jumlah trombosit, dan fungsi agregasi yang terjadi pada trombosit pada beberapa hari penyimpanan.Metode: Disain penelitian potong lintang terhadap sample kantong konsentrat trombosit yang yang telahlolos skrining infeksi penyakit menular melalui transfusi darah. Pengujian yang dilakukan ialah terhadappH, jumlah trombosit dan fungsi agregasi terhadap sampel pada tiga waktu pengujian pada hari ke-0, ketiga, dan ke lima penyimpanan.Hasil: Pada 50 sampel kantong konsentrat trombosit didapatkan kenaikan pH pada hari ke tigapenyimpanan kantong trombosit yang disertai penurunan pada hari ke lima. Hal serupa ditemui pulapada jumlah trombosit. Sementara penurunan fungsi agregasi trombosit ditemukan lebih awal pada harike tiga penyimpanan dan didapatkan nilai rendah pada hampir semua sampel.Kesimpulan: Ketiga parameter yaitu pH, jumlah trombosit, dan fungsi agregasi mengalami penurunanpada hari kelima. (Health Science Journal of Indonesia;2015;6:48-51Kata kunci: thrombocyte, concentrate, pH, agregasi, waktu penyimpanan. AbstractBackground: Evaluation for platelet transfusion is not optimal for this moment even in upstream at theblood center or in downstream at the hospital. The purpose of this study was to determine the effect ofstorage time to changes in pH, platelet count and function that occurs on platelet aggregation duringdifferent time storage.Methods: The study design was cross-sectional on selected bags of platelet concentrates that have passedthe screening for infection transmitted through blood transfusions. The regular assessment in UTDD forPC has been done every month by random sampling with three parameters pH, platelets count and volumein the bag of blood. The testing for pH, platelet count, and aggregation functions for 50 samples

  15. Effects of anti-malarial alkaloids on the sperm properties and blood ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-10-06

    Oct 6, 2008 ... 2Department of Physiology, Delta State University, Abraka, Nigeria. ... sperm count, percentage sperm forward motility and blood levels of testosterone were ... be associated with fertility changes as a result of their inherent ...

  16. Congenital and nosocomial sepsis in infants born in a regional perinatal unit: cause, outcome, and white blood cell response.

    Science.gov (United States)

    Ohlsson, A; Vearncombe, M

    1987-02-01

    The incidence, cause, and outcome of sepsis and the white blood cell response were studied in 6315 infants born in a regional perinatal unit. The incidence of neonatal sepsis was 6.5 per 1000 live births. Congenital sepsis (12 cases) was overwhelming, with associated maternal infection (92%), neutropenia (75%), and high rate of mortality (50%). The most common organism was Escherichia coli (58%). Gestational age and birth weight were similar in survivors and nonsurvivors. There was a strong correlation between total white blood cell count and both mature and immature neutrophil counts in survivors but this correlation decreased substantially in neonates that died. Analysis of variance indicated that the means for polymorphonuclear leukocyte and immature neutrophil counts were significantly higher in survivors. Nosocomial sepsis (38 cases) occurred in premature low birth weight infants receiving invasive, intensive care. The most common organism was Staphylococcus epidermidis (76%). Total white blood cell, polymorphonuclear leukocyte, and immature neutrophil counts rose significantly in response to sepsis. None died. Prevention of congenital sepsis requires methods to detect early maternal-fetal infection. Providing granulocytes to neutropenic neonates with congenital sepsis might improve outcome.

  17. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  18. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  19. Correlation between total lymphocyte count, hemoglobin, hematocrit and CD4 count in HIV patients in Nigeria.

    Science.gov (United States)

    Emuchay, Charles Iheanyichi; Okeniyi, Shemaiah Olufemi; Okeniyi, Joshua Olusegun

    2014-04-01

    The expensive and technology limited setting of CD4 count testing is a major setback to the initiation of HAART in a resource limited country like Nigeria. Simple and inexpensive tools such as Hemoglobin (Hb) measurement and Total Lymphocyte Count (TLC) are recommended as substitute marker. In order to assess the correlations of these parameters with CD4 count, 100 "apparently healthy" male volunteers tested HIV positive aged ≥ 20 years but ≤ 40 years were recruited and from whom Hb, Hct, TLC and CD4 count were obtained. The correlation coefficients, R, the Nash-Sutcliffe Coefficient of Efficiency (CoE) and the p-values of the ANOVA model of Hb, Hct and TLC with CD4 count were assessed. The assessments show that there is no significant relationship of any of these parameters with CD4 count and the correlation coefficients are very weak. This study shows that Hb, Hct and TLC cannot be substitute for CD4 count as this might lead to certain individuals' deprivation of required treatment.

  20. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  1. Preoperative predictors of blood component transfusion in living donor liver transplantation

    Directory of Open Access Journals (Sweden)

    R N Makroo

    2013-01-01

    Full Text Available Context: Extensive bleeding associated with liver transplantation is a major challenge faced by transplant surgeons, worldwide. Aims: To evaluate the blood component consumption and determine preoperative factors that predict the same in living donor liver transplantation (LDLT. Settings and Design: This prospective study was performed for a 1 year period, from March 2010 to February 2011. Materials and Methods: Intra- and postoperative utilization of blood components in 152 patients undergoing LDLT was evaluated and preoperative patient parameters like age, gender, height, weight, disease etiology, hemoglobin (Hb, hematocrit (Hct, platelet count (Plt, total leukocyte count (TLC, activated partial thromboplastin time (aPTT, international normalized ratio (INR, serum bilirubin (T. bilirubin, total proteins (T. proteins, albumin to globulin ratio (A/G ratio, serum creatinine (S. creatinine, blood urea (B. urea, and serum electrolytes were assessed to determine their predictive values. Univariate and stepwise discriminant analysis identified those factors, which could predict the consumption of each blood component. Results: The average utilization of packed red cells (PRCs, cryoprecipitates (cryo, apheresis platelets, and fresh frozen plasma was 8.48 units, 2.19 units, 0.93 units, and 2,025 ml, respectively. Disease etiology and blood component consumption were significantly correlated. Separate prediction models which could predict consumption of each blood component in intra and postoperative phase of LDLT were derived from among the preoperative Hb, Hct, model for end-stage liver disease (MELD score, body surface area (BSA, Plt, T. proteins, S. creatinine, B. urea, INR, and serum sodium and chloride. Conclusions: Preoperative variables can effectively predict the blood component requirements during liver transplantation, thereby allowing blood transfusion services in being better prepared for surgical procedure.

  2. You can count on the motor cortex: Finger counting habits modulate motor cortex activation evoked by numbers

    Science.gov (United States)

    Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H.; Pulvermüller, Friedemann

    2012-01-01

    The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. PMID:22133748

  3. EFFECTS OF COMBINATION THERAPY ON PLATELET COUNT IN PATIENTS OF MYOCARDIAL INFARCTION

    Directory of Open Access Journals (Sweden)

    Sadaf Ahmed

    2014-12-01

    Full Text Available Aspirin and clopidogrel are usually used individually to prevent adverse cardiovascular events and stroke. They are used in stabilizing the blood pressure in patients of myocardial infarction while combination therapy of aspirin and Clopidogrel (dual anti-platelet therapy is used for preventing adverse cardiovascular events in myocardial infarction patients. A cross-sectional observational study is conducted through a structured questionnaire from 110 patients of K.I.H.D (Karachi Institute of Heart Disease hospital, Karachi, Pakistan. Indoor/admitted patients with diagnosis of acute coronary syndrome (ACS, non-ST elevation myocardial infarction (NSTE-MI, ST elevation myocardial infarction (STE-MI, supra ventricular tachycardia (SVT were included along with those with previous or current onset of angina pectoris or heart attack. Information from the test reports of these patients was included in the data. Patients without proper test reports were excluded from the study. Combination therapy duration is considered as key tool for evaluation. Out of 100 patients (after exclusion criteria applied almost 18% patients were using the combination therapy for 10 to 25 years while 52% of patients were using the combination therapy for 1 to 10 years. Platelet count of 88% patients was found to be in between 1,50,000–3,50,000/µl. Remaining patients had less than 1,50,000 µl to more than 3,50,000 to 4,50,000 µl. Most frequently reported side effects were chest pain, respiratory issues, headache and depression. On the basis of our data analysis it is concluded that long duration dual anti-platelet therapy will not harm platelet count in human blood but it can create drug dependency in patients. Hypertension is not completely cured with this therapy but can help in stabilizing blood pressure.

  4. The nutritional status affects the complete blood count of goats experimentally infected with Haemonchus contortus.

    Science.gov (United States)

    Cériac, S; Jayles, C; Arquet, R; Feuillet, D; Félicité, Y; Archimède, H; Bambou, J-C

    2017-11-09

    Gastrointestinal nematode (GIN) remains the most important pathogenic constraint of small ruminant production worldwide. The improvement of the host immune response against GIN though breeding for improved animal resistance, vaccination and nutritional supplementation appear as very promising methods. The objective of this study was to investigate the effect of four nutritional status differing in protein and energy levels (Hay: 5.1 MJ/Kg of dry matter (DM) and 7.6% of crude protein (CP), Ban: 8.3 MJ/Kg of DM and 7.5% of CP, Soy: 7.6 MJ/Kg of DM and 17.3% of CP, BS: 12.7 MJ/Kg of DM and 7.4% of CP) on the haematological disturbances due to Haemonchus contortus infection in Creole kid goats. No significant effect of the nutritional status was observed for faecal egg count (FEC) but the experimental infection induced haematological disturbances whose intensity and lengthening were dependent on the nutritional status. A transient marked regenerative macrocytic hypochromic anaemia as revealed by a decrease of packed cell volume (PCV), red blood cells (RBC) and hemoglobin and an increase of reticulocytes was observed in all infected groups except Hay. In this latter, the anaemia settled until the end of the experiment. Furthermore, H. contortus induced a thrombocytopenia significantly more pronounced in the group under the lowest nutritional status in term of protein (Hay and Ban). A principal component analysis revealed that the variables that discriminated the nutritional status were the average daily gain (ADG) and the PCV, considered as measures of the level of resilience to H. contortus infection. Moreover, the variables that discriminated infected and non-infected animals were mostly related to the biology of RBC (i.e. size and hemoglobin content) and they were correlated with FEC. The severity and the lengthening of the regenerative anaemia and the thrombocytopenia induced by H. contortus have been affected by the nutritional status. The protein enriched

  5. Blood leukocyte responses to extracorporeal circulation. 2. Medium term extracorporeal circulation without and with extracorporeal irradiation in normal and splenectomized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, P.; Fliedner, T.M. (Ulm Univ. (Germany, F.R.). Abt. Klinische Physiologie)

    1983-01-01

    Medium term (6-8 h) extracorporeal irradiation without and with irradiation of blood was performed in normal and splenectomized dogs to reveal the changes of blood leukocytes including CFU-C. A regular but transitory decrease of granulocytes and a longer lasting diminution of lymphocytes in the blood were observed. The CFU-C level became and mostly remained very low during the procedure. Splenectomy did not influence significantly the changes of peripheral leukocyte counts. No marked difference of leukocytes was seen in the blood samples taken from the arterial or venous side of the shunt or even from the cubital vein. Also, the irradiation did not produce any difference in the alterations of blood cell counts compared to those without irradiation. The possible explanations of these results are discussed.

  6. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  7. Effect of artificial photoperiod on the blood cell indices of the catfish, Clarias batrachus

    Directory of Open Access Journals (Sweden)

    S Srivastava

    2010-04-01

    Full Text Available The present study is aimed to assess the influence of artificial photoperiod on the blood cell indices of an Indian catfish, Clarias batrachus(Linn.. Blood samples taken from adult fishes exposed to artificial photoperiod of 24L:0D and 0L:24D for a short period of 24 hrs, were analyzed for total RBC, total WBC, differential leukocyte count (DLC and some physiological variables – glucose and chloride. The total RBC and WBC counts were unaffected by both the artificial photoperiod regimes. However, lymphopenia (p<.05 and neutrophilia (p<.05 were observed under 24L:0D photoperiod. Blood chloride levels were significantly higher (p<.05 in 24L:0D whereas blood glucose levels remained unchanged in both the photoperiod treatments. The 0L:24D photoperiod did not produce any significant change in the blood cell indices neither in the physiological variables. The findings indicate that exposure to continuous light for as short a duration as of 24 hrs elicits stress responses in the leukocyte profile of this nocturnal fish and highlights the role of leukocyte profile as potential stress biomarkers in vertebrates.

  8. Six-day stability of erythrocyte and reticulocyte parameters in-vitro: a comparison of blood samples from healthy, iron-deficient, and thalassemic individuals.

    Science.gov (United States)

    Sudmann-Day, Åshild A; Piehler, Armin; Klingenberg, Olav; Urdal, Petter

    2015-05-01

    Stability for up to 6 days' storage of erythrocyte and reticulocyte parameters in samples from iron-deficient and thalassemic individuals has not yet been reported. This lack of knowledge challenges evaluation of the full blood count in referral samples for hemoglobinopathy evaluation. We therefore hereby present such sample stability data. We included fresh (less than 4 hours old) blood samples from eight healthy, eight iron-deficient, and 11 thalassemic individuals. A full blood count, including reticulocyte parameters, was performed on a Sysmex XE-2100 once daily during a 6-day storage period at room temperature. For healthy individuals, we also studied stability of refrigerated samples and investigated analytical and biological variation. Hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin were stable for 6 days in all diagnostic groups. Mean corpuscular volume increased less in samples from iron-deficient individuals while the number of reticulocytes increased more in samples from thalassemic, as compared to healthy individuals. Ret-He stability depended on its baseline value. Within-person biological variation in samples from healthy individuals was low both for erythrocyte parameters and for reticulocyte hemoglobin, while higher for reticulocyte counts. Results for hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin are reliable in hemoglobinopathy investigation of referred samples for up to 6 days. Storage time-dependent changes of other erythrocyte and reticulocyte parameters in blood samples from iron-deficient and thalassemic individuals differ from those of healthy individuals.

  9. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  10. Hyperleucocytosis in paediatric acute myeloid leukaemia - the challenge of white blood cell counts above 200 × 10(9) /l. The NOPHO experience 1984-2014

    DEFF Research Database (Denmark)

    Zeller, Bernward; Glosli, Heidi; Forestier, Erik

    2017-01-01

    on very high white blood cell counts (WBC >200 × 10/l). Eighty-six patients (10%) had WBC 100-199 × 109 /l and 57 (6%) had WBC ≥200 × 109 /l. Patients with WBC ≥200 × 109 /l had a high frequency of t(9;11) and a paucity of trisomy 8. Due to the high frequency of deaths within the first 2 weeks (30% vs. 1......% for all others), overall survival in this group was inferior to patients with WBC vs. 61%). Main cause of early death was intracranial haemorrhage and leucostasis. Twenty-six per cent of these patients never started antileukaemic protocol therapy. Leukapheresis or exchange transfusion...... was used in 24% of patients with hyperleucocytosis without impact on survival. Patients with hyperleucocytosis surviving the first week had identical survival as patients with lower WBC. We conclude that death within the first days after diagnosis is the major challenge in patients with high WBC...

  11. Drone transportation of blood products.

    Science.gov (United States)

    Amukele, Timothy; Ness, Paul M; Tobian, Aaron A R; Boyd, Joan; Street, Jeff

    2017-03-01

    Small civilian unmanned aerial vehicles (drones) are a novel way to transport small goods. To the best of our knowledge there are no studies examining the impact of drone transport on blood products, describing approaches to maintaining temperature control, or component physical characteristics during drone transport. Six leukoreduced red blood cell (RBC) and six apheresis platelet (PLT) units were split using sterile techniques. The larger parent RBC and PLT units, as well as six unthawed plasma units frozen within 24 hours of collection (FP24), were placed in a cooler, attached to the drone, and flown for up to 26.5 minutes with temperature logging. Ambient temperatures during the experimental window ranged between -1 and 18°C across 2 days. The difference between the ambient and unit temperatures was approximately 20°C for PLT and FP24 units. After flight, the RBC parent units were centrifuged and visually checked for hemolysis; the PLTs were checked for changes in mean PLT volumes (MPVs), pH, and PLT count; and the frozen air bubbles on the back of the FP24 units were examined for any changes in size or shape, as evidence of thawing. There was no evidence of RBC hemolysis; no significant changes in PLT count, pH, or MPVs; and no changes in the FP24 bubbles. The temperature of all units was maintained during transport and flight. There was no adverse impact of drone transport on RBC, PLT, or FP24 units. These findings suggest that drone transportation systems are a viable option for the transportation of blood products. © 2016 AABB.

  12. Radiographic evaluation of destructive periodontal disease in blue mink in relation to age and blood morphology

    DEFF Research Database (Denmark)

    Hammer, Anne Sofie; Andersen, Thomas Holmen; Eriksen, Thomas

    2005-01-01

    In this study, blood samples and jaws were collected from 2 genotypes of blue mink (n = 289) in order to examine phenotypic expression of specific characteristics of Chediak-Higashi Syndrome (C-HS). Blood samples were subjected to differential counts to assess the proportion of abnormal polymorph...

  13. Increment of absolute neutrophil count in the third trimester and increased risk of small-for-gestational-age birth: Hirakata Risk Associated with Pregnancy Assessment Research (HIRAPAR).

    Science.gov (United States)

    Harita, Nobuko; Kariya, Masatoshi; Hayashi, Tomoshige; Sato, Kyoko Kogawa; Nakamura, Kimihiko; Endo, Ginji; Narimoto, Katsuhiko

    2012-09-01

    Small-for-gestational-age (SGA) infants, who have growth restriction, have higher perinatal morbidity and mortality. Excessive inflammatory reaction such as neutrophil activation has been observed in pregnant women whose offspring had restricted fetal growth, but the association between white blood cell (WBC) counts and SGA birth has not yet been assessed. We therefore examined the association of WBC count and its change with the risk of SGA birth. We enrolled 2356 pregnant women who had full-term singleton delivery at a private maternity hospital in Hirakata, Japan. SGA was defined as under the 10th percentile of birthweight for gestational age, baby sex, and mother's parity according to the Japanese neonatal anthropometric charts renewed in 2010. Blood samples were measured in the first and third trimesters. We performed multiple logistic regression analysis to assess associations between total and differential WBC counts and SGA birth. Women with SGA birth tended to have higher total WBC count in the third trimester compared with women who did not have SGA birth. This tendency was not observed for total WBC count in the first trimester. After adjustment for age, height, body mass index at entry, smoking habit, weekly gestational weight gain, and pregnancy-induced hypertension, higher total WBC count in the third trimester was associated with an increased risk of SGA birth. Total WBC count in the first trimester did not show any significant association with SGA birth. The ratio of total WBC count in the third trimester to that in the first trimester was associated with SGA birth; the odds ratio for 1 unit increase was 3.02 (95% CI: 1.54-5.92). Regarding differential WBC counts in the third trimester, neutrophil count but not lymphocyte count was associated positively with SGA birth. Higher total WBC and absolute neutrophil counts in the third trimester were associated with SGA birth. In addition, greater ratio of increase in total WBC counts during pregnancy

  14. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  15. Factors influencing CD4 cell count in HIV-positive pregnant women in a secondary health center in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Akinbami AA

    2015-04-01

    Full Text Available Akinsegun A Akinbami,1 Abidoye Gbadegesin,2 Sarah O Ajibola,3 Ebele I Uche,1 Adedoyin O Dosunmu,1 Adewumi Adediran,4 Adekunle Sobande2 1Department of Haematology and Blood Transfusion, 2Department Of Obstetrics and Gynaecology, College of Medicine, Lagos State University, Ikeja, Lagos, Nigeria; 3Department of Haematology and Immunology, Ben-Carson School of Medicine, Babcock University, Ilisan, Ogun State, Nigeria; 4Department of Haematology and Blood Transfusion, Faculty of Clinical Sciences, College of Medicine, University of Lagos, Lagos, Nigeria Background: Immunity in pregnancy is physiologically compromised, and this may affect CD4 count levels. It is well-established that several factors affect CD4 count level in pregnancy. This study aimed to determine the mean and reference range of CD4 count in human immunodeficiency virus (HIV-positive pregnant women in Lagos, Nigeria. Methods: A retrospective study was carried out at antenatal clinics of the Maternal and Child Center of a secondary health center in Lagos State, Nigeria. Records of HIV-positive pregnant women at various gestational ages, including CD4+ cell count at booking, packed cell volume (PCV at booking and labor, gestational age at delivery, and infant weight and sex were retrieved. The descriptive data was given as mean ± standard deviation (SD. Pearson's chi-squared test and correlation were used for analytical assessment. Results: Data were retrieved for a total of 143 patients. The mean age was 31.15±3.78 years. The mean PCV was 31.01%±3.79% at booking and 30.49%±4.80% during labor. The mean CD4 count was 413.87±212.09 cells/µL, with a range of 40 to 1,252 cells/µL. The mean infant weight was 3.05±0.45 kg, with a range of 2 to 5 kg. Age of the mother, gestational age, and PCV at booking were not statistically significantly associated with CD4 count. Conclusion: Maternal age, gestational age, and PCV at booking had no significant effects on CD4+ cell count levels in

  16. Increased levels of C-reactive protein and leukocyte count are poor predictors of anastomotic leakage following laparoscopic colorectal resection

    DEFF Research Database (Denmark)

    Pedersen, Torben; Roikjær, Ole; Jess, Per

    2012-01-01

    Laparoscopic procedure and fast-track regimen with short post-operative hospital stay are gaining ground in colorectal surgery. The aim of the present study was to determine whether the levels of C-reactive protein (CRP) and white blood cell counts (WBC) have a role as early predictors of post...

  17. ASSOCIATION OF BIRTH ASPHYXIA WITH CORD BLOOD NUCLEATED RED BLOOD CELL

    Directory of Open Access Journals (Sweden)

    Poornima Shankar

    2018-02-01

    Full Text Available BACKGROUND Asphyxia can lead to severe hypoxic ischaemic organ damage in new-borns which may cause postnatal manifestation of hypoxicischaemic encephalopathy. Studies have found that the Apgar score failed to predict specific neurologic outcomes of the infants. Increased cord blood nucleated red blood cell in term neonates is an indicator of chronic intrauterine hypoxia. We set out to assess the role of nucleated RBC as a non-invasive, easy, cheap and at the same time early biochemical means of asphyxia diagnosis in our clinical setting. MATERIALS AND METHODS All inborn babies with Apgar scores <7 at 1 and 5 minutes of life were reviewed. Relevant information from mother case sheet were obtained. Cord blood samples was drawn and sent for blood gas analysis and number of NRBCs/100 white blood cells (WBC was determined using Leishman stain. RESULTS Our study proves the relevance of increase nucleated RBC in terms of early detection of birth asphyxia. Most common cause of birth asphyxia found was meconium aspiration. No co-relation was found with chorioamnionitis or maternal obstetrical history. CONCLUSION Many specific biomarkers are being investigated now a day for early detection of birth asphyxia. Umbilical cord pH is costly and may be underestimated in birth asphyxia. In our study, the elevated cord blood nRBC count was shown to be a good predictor of perinatal asphyxia. Since, it is cost-effective and does not require any special expertise or any high-tech facilities, it may be a useful, reliable, inexpensive and easily available marker to evaluate perinatal asphyxia. Hence, increase nucleated RBC has an important role in diagnosing and predicting the outcome of perinatal asphyxia.

  18. New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: quality of blood components.

    Science.gov (United States)

    Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A

    2014-10-01

    TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.

  19. TSH IRMA of dried blood spots

    International Nuclear Information System (INIS)

    Tojinda, N.; Pattanachak, C.; Chongchirasiri, S.; Pattanachak, S.; Putrasreni, N.; Pleehachinda, R.; Suwanik, R.

    1990-01-01

    TSH determination is most useful for screening of neonatal hypothyroid in the population in iodine deficient areas. The NETRIA IRMA method for serum TSH was applied for blood-spot TSH. Cord blood on SS No. 903 filter paper was left dry overnight. The spot of 6 mm diameter, one/tube, was mixed with an assay buffer, diluted labelled m-anti-TSH, and diluted anti-TSH-solid phase. The mixture was rotated for 22-24 hours. After washing twice with wash buffer, it was counted for 1 minute. The standard curve with 0, 5, 10, 25, 50, 100, and 150 mIU/L whole blood was obtained with the maximum binding of 25%. The precision profile was satisfactory with %CV of 0 C) or 4 0 C or -20 0 C. The correlation between serum and blood-spot TSH values (n=120) showed r of 0.9541 and y=1.6123 (BS-TSH) +1.382. The mean of normal cord blood spot TSH (n=142) was 5.27 mIU/L. The technique was found to be precise, sensitive and easy to perform. Mass screening with this developed method is underway

  20. Monitoring of benzene-induced hematotoxicity in mice by serial leukocyte counting using a microcavity array.

    Science.gov (United States)

    Hosokawa, Masahito; Asami, Marie; Yoshino, Tomoko; Tsujimura, Noriyuki; Takahashi, Masayuki; Nakasono, Satoshi; Tanaka, Tsuyoshi; Matsunaga, Tadashi

    2013-02-15

    Monitoring of hematotoxicity, which requires serial blood collection, is difficult to carry out in small animals due to a lack of non-invasive, individual animal-appropriate techniques that enable enumeration of leukocyte subsets from limited amounts of whole blood. In this study, a microfluidic device equipped with a microcavity array that enables highly efficient separation of leukocytes from submicroliters of whole blood was applied for hematotoxicity monitoring in mice. The microcavity array can specifically separate leukocytes from whole blood based on differences in the size and deformability between leukocytes and other blood cells. Mouse leukocytes recovered on aligned microcavities were continuously processed for image-based immunophenotypic analysis. Our device successfully recovered almost 100% of mouse leukocytes in 0.1 μL of whole blood without the effect of serial blood collection such as changes in body weight and total leukocyte count. We assessed benzene-associated hematotoxicity in mice using this system. Mice were administered with benzene once daily and the depression of leukocyte numbers induced in individual mice was successfully monitored from tail vein blood collected every other day for 2 weeks. Serial monitoring of the leukocyte number in individual mice will contribute to the understanding of hematotoxicity and reduction of the number of animal experiment trials. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Analysis of Macular Drusen and Blood Test Results in 945 Macaca fascicularis.

    Directory of Open Access Journals (Sweden)

    Koji M Nishiguchi

    Full Text Available Age-dependent formation of macular drusen caused by the focal accumulation of extracellular deposits beneath the retinal pigment epithelium precede the development of age-related macular degeneration (AMD, one of the leading causes of blindness worldwide. It is established that inflammation contributes to the pathogenesis of drusen and AMD. However, development of a preemptive therapeutic strategy targeting macular drusen and AMD has been impeded by the lack of relevant animal models because most laboratory animals lack macula, an anatomic feature present only in humans and a subset of monkeys. Reportedly, macular drusen and macular degeneration develop in monkeys in an age-dependent manner. In this study, we analyzed blood test results from 945 Macaca fascicularis, 317 with and 628 without drusen. First, a trend test for drusen frequency (the Cochran-Armitage test was applied to the quartile data for each parameter. We selected variables with an increasing or decreasing trend with higher quartiles at P < 0.05, to which multivariate logistic regression analysis was applied. This revealed a positive association of age (odds ratio [OR]: 1.10 per year, 95% confidence interval [CI]: 1.07-1.12 and white blood cell count (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.01 with drusen. When the monkeys were divided by age, the association between drusen and white blood cell count was only evident in younger monkeys (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.02. In conclusion, age and white blood cell count may be associated with drusen development in M. fascicularis. Systemic inflammation may contribute to drusen formation in monkeys.

  2. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  3. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  4. Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis.

    Science.gov (United States)

    Zhu, Hongying; Ozcan, Aydogan

    2015-01-01

    Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform

  5. [Measurement of the blood flow in various areas of the rat brain by means of microspheres].

    Science.gov (United States)

    Deroo, J; Gerber, G B

    1976-01-01

    A method is described to measure regional blood flow in different structures of the rat brain. Microspheres (15 micron) are injected, the brain is sectioned, stained for myeline, radioautographs are prepared and the microspheres in the different structures are counted. The values obtained for different brain structures are counted. The values obtained for different brain regions (cortex, corpus callosum, thalamus hipocampus, hypothalamic region, colliculi, cerebellum, pons, medulla) compare well with those published by others on larger animals. In rats fed 1% of lead from birth, higher blood flow is found in the cortex and a lower one in the interior part of the brain compared to controls.

  6. Blood lead levels in preschool children in Cape Town

    Energy Technology Data Exchange (ETDEWEB)

    Deveaux, P.; Kibel, M.A.; Dempster, W.S.; Pocock, F.; Formenti, K.

    1986-03-29

    Blood lead levels were assessed in 293 children aged between 4 and 6 years attending preschool centers in metropolitan Cape Town in order to establish the degree of lead absorption. Anthropometric data, blood count, zinc protoporphyrin and blood lead level were obtained for each child. A questionnaire was used to determine socio-economic status, dietary habits and history of pica. Thirteen children, or 4,4% of those sampled, had blood levels of greater than or equal to 30 micrograms/dl. The majority of these children lived in close proximity to one another in a socially deprived inner urban environment. Environmental sampling for lead was carried out in the homes of children with the highest blood levels as well as in the homes of a matched control group with low levels living in the same area. The only difference was a significantly higher incidence of pica in the children with high levels.

  7. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  8. Total bacterial count and somatic cell count in refrigerated raw milk stored in communal tanks

    Directory of Open Access Journals (Sweden)

    Edmar da Costa Alves

    2014-09-01

    Full Text Available The current industry demand for dairy products with extended shelf life has resulted in new challenges for milk quality maintenance. The processing of milk with high bacterial counts compromises the quality and performance of industrial products. The study aimed to evaluate the total bacteria counts (TBC and somatic cell count (SCC in 768 samples of refrigerated raw milk, from 32 communal tanks. Samples were collected in the first quarter of 2010, 2011, 2012 and 2013 and analyzed by the Laboratory of Milk Quality - LQL. Results showed that 62.5%, 37.5%, 15.6% and 27.1% of the means for TBC in 2010, 2011, 2012 and 2013, respectively, were above the values established by legislation. However, we observed a significant reduction in the levels of total bacterial count (TBC in the studied periods. For somatic cell count, 100% of the means indicated values below 600.000 cells/mL, complying with the actual Brazilian legislation. The values found for the somatic cell count suggests the adoption of effective measures for the sanitary control of the herd. However, the results must be considered with caution as it highlights the need for quality improvements of the raw material until it achieves reliable results effectively.

  9. Association of Pulse Pressure with Serum TNF-α and Neutrophil Count in the Elderly

    Directory of Open Access Journals (Sweden)

    Eriko Yamada

    2014-01-01

    Full Text Available Aims. Elevated pulse pressure (PP has been reported to be a risk factor for type 2 diabetes in elderly patients with hypertension. Methods. Cross-sectional relationships of PP with known risk factors for type 2 diabetes and inflammatory markers were examined in 150 elderly community-dwelling women, 79 women (52.7% of whom had hypertension. Results. Systolic blood pressure (standardized β, 0.775, log tumor necrosis factor-α (TNF-α, standardized β, 0.110, age (standardized β, 0.140, and neutrophil count (standardized β, 0.114 emerged as determinants of PP independent of high-sensitivity C-reactive protein, interleukin-6, monocyte count, plasminogen activator inhibitor-1, homeostasis model assessment of insulin resistance, HDL-cholesterol, and adiponectin (R2 = 0.772. Conclusions. The present studies have demonstrated an independent association of higher PP with higher TNF-α, a marker of insulin resistance, and neutrophil count in community-living elderly women and suggest that insulin resistance and chronic low-grade inflammation may in part be responsible for the association between high PP and incident type 2 diabetes found in elderly patients with hypertension.

  10. EFFECT OF FERMENTED Sauropus androgynus LEAVES ON BLOOD LIPID FRACTION AND HAEMATOLOGICAL PROFILE IN BROILER CHICKENS

    Directory of Open Access Journals (Sweden)

    U. Santoso

    2015-12-01

    Full Text Available This study was conducted to evaluate effect of fermented Sauropus androgynus leaves on blood lipid fractions and haematological profiles in broilers. One hundred and twelve broilers were distributed to 7 treatment groups. One group was fed diets without Sauropus androgynus leaves as the control, and other six groups were fed Sauropus androgynus leaves fermented by Neurospora crassa, Lactobacillus sp. or Saccharomyces cerevisiae at level of 25 g or 50 g/kg diet. Experimental results showed that the treatments had no effect on cholesterol, high-density lipoprotein cholesterol (HDL-c, low-density lipoprotein cholesterol (LDL-c and atherogenic index, very low-density lipoprotein cholesterol (VLDL-c and triglyceride concentration (P>0.05. It was shown that fermented Sauropus androgynus leaves significantly affected red blood count (RBC, white blood count (WBC, packed cell volume (PCV, trombosit dan erythrocyte sedimentation rate (ESR (P

  11. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  12. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  13. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R

    2011-01-01

    in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP...

  14. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  15. Comparison of hematologic values in blood samples with lithium heparin or dipotassium ethylenediaminetetraacetic acid anticoagulants in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Guzman, David Sanchez-Migallon; Mitchell, Mark A; Gaunt, Stephen D; Beaufrère, Hugues; Tully, Thomas N

    2008-06-01

    Blood samples were collected from 20 Hispaniolan Amazon parrots (Amazona ventralis) and were divided into tubes that contained dipotassium ethylenediaminetetraacetic acid (K2EDTA) and lithium heparin. Complete blood cell counts were determined in each sample within 2 hours of collection. The level of agreement in results was moderate for plasma protein, packed cell volume (PCV), and leukocyte, monocyte, and lymphocyte counts between the anticoagulants. Plasma protein and PCV values were significantly lower in samples with lithium heparin than in those with K2EDTA, whereas lymphocyte numbers were significantly higher in lithium heparin samples than in K2EDTA samples. The level of agreement was good for the other cell types (heterophils, eosinophils, and basophils) when comparing the different anticoagulants. The poor level of agreement between anticoagulants with the increase in thrombocyte clumping in lithium heparin samples indicates that the use of lithium heparin as anticoagulant may affect thrombocyte count. No negative effects on morphology and staining of blood cells were apparent in smears from heparin samples compared with K2EDTA samples. Within the different values compared, the limits of agreement are small enough to be confident that lithium heparin can be used for routine CBC counts in a clinical setting. The use of the same anticoagulant should be recommended to follow trends within the same patient, especially when considering plasma protein concentration, PCV, and lymphocyte count.

  16. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  17. A simple and efficient method for measuring the uptake of radiolabelled compounds by leukocytes in whole blood

    International Nuclear Information System (INIS)

    Pauly, J.L.; Schuller, M.G.; Germain, M.J.

    1977-01-01

    A liquid scintillation counting procedure is described for measuring the uptake of radiolabelled compounds by leukocytes in large or small volumes of whole blood. Color and chemical quenching as well as other technical difficulties noted previously by investigators attempting to process whole blood were eliminated by selectively disrupting the erythrocytes. This was readily accomplished by washing the blood with 3% acetic acid. After bleaching the leukocyte pellet with hydrogen peroxide, the sample was prepared for counting using methods in which the cells were dissolved or oxidized. Examples demonstrating the utility of the proposed technique are presented in which DNA, RNA and protein synthesis of leukocytes from patients with uncontrolled leukemia were measured by the uptake of tritiated thymidine, uridine and leucine, respectively. Also noted is the feasibility of employing a multiple automated sample harvester and whole blood microcultures. The advantages realised by these methods and their potential clinical and experimental utility are discussed. (author)

  18. effect of thermal stress of short duration on the red blood cell

    African Journals Online (AJOL)

    Dr Ivanc

    2013-05-01

    May 1, 2013 ... of red blood cell count (RBC), haemoglobin concentration, packed cell volume ... The temperature at which stress begins to occur ..... of Barton (2002) that PCV is a measure of the cellular ..... Tufts B (eds) Fish respiration.

  19. Inhibition of Platelet Aggregation by Supernates from Stored Red Blood Cells

    Science.gov (United States)

    2010-04-01

    450 μl of blood or 450 μl of platelet rich plasma (PRP) was mixed with 225 μl of supernate plus 225 μl of Tyrode’s buffer and incubated for ten... platelet counts, prothrombin time, activated partial thromboplastin time, fibrinogen, fibrin split products, and FVIII:Rag also measured 30 minutes...RTO-MP-HFM-182 22 - 1 Inhibition of Platelet Aggregation by Supernates from Stored Red Blood Cells Dr. Steve J. McFaul, LT Frederick A

  20. Interaction of low-intensity nuclear radiation dose with the human blood: Using the new technique of CR-39NTDs for an in vitro study

    International Nuclear Information System (INIS)

    Ismail, Asaad H.; Jaafar, Mohamad S.

    2011-01-01

    Complete blood counts were analyzed for 30 samples of human blood with radiation dose rate ranging between 10 and 41 μSv/h using a Radium-226 source with different time of exposure. A new technique involving a nuclear track detector type CR-39(CR-39 NTDs) was used to estimate the alpha particle density incident on the blood samples. The results show that the ranges of alpha particle in blood samples and on the surface of CR-39NTDs vary exponentially with energy of alpha particles. This depends on the restricted energy loss and target density. Changes in the blood components due to irradiation occurred for different durations of irradiation, and the duration of irradiation that influenced the blood samples in this study was 6 min. The change in red blood cell (RBC) was negligible, so it is less affected than other blood components. In addition, most changes in the blood contents began at a low radiation dose (10.38-13.41 μSv/h). For the doses 13.41-21.77 μSv/h, platelet (PLT) counts increased rapidly and adversely with the RBC and white blood cell (WBC) due to chromosomal aberration. Besides, rapid PLT count reduction rapidly at high dose (42.1 μSv h) causes thrombocytopenia; in contrast, WBC increased, which is an indication of cancer caused due to increase in alpha particle dose. Generally, our results are in agreement with the essentials of blood content and the principles of biological radiation interaction.

  1. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  2. Variation of Red Blood Cell Distribution Width and Mean Platelet Volume after Moderate Endurance Exercise

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2014-01-01

    Full Text Available Although physical exercise strongly influences several laboratory parameters, data about the hematological changes after medium distance running are scarce. We studied 31 middle-trained athletes (mean training regimen 217±32 min/week who performed a 21.1 km, half-marathon run. Blood samples were collected before the run, at the end, and 3 and 20 hours thereafter. The complete blood count was performed on Advia 2120 and included red blood cell (RBC, reticulocyte, and platelet counts; hemoglobin; mean corpuscular volume (MCV; mean corpuscular hemoglobin (MCH; reticulocyte haemoglobin content (Ret CHR; RBC distribution width (RDW, mean platelet volume (MPV. No significant variations were observed for MCH and Ret CHR. The RBC, reticulocyte, and hemoglobin values modestly decreased after the run. The MCV significantly increased at the end of running but returned to baseline 3 hours thereafter. The RDW constantly increased, reaching a peak 20 hours after the run. The platelet count and MPV both increased after the run and returned to baseline 3 hours thereafter. These results may have implications for definition of reference ranges and antidoping testing, and may also contribute to explaining the relationship between endurance exercise and mortality, since previous studies reported that RDW and MPV may be significantly associated with cardiovascular disease.

  3. Blood leukocyte responses to extracorporeal circulation. 1. Short term extracorporeal circulation in dogs without and with extracorporeal irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, P.; Fliedner, T.M. (Ulm Univ. (Germany, F.R.). Abt. Klinische Physiologie)

    1983-01-01

    Short term (1 h) extracorporeal circulation without or with irradiation of blood was performed in two normal dogs in a series of experiments. The granulocyte count was constantly diminished, while the lymphocytes did not show any particular change in their concentration. In the majority of the experiments a decrease of the CFU-C content occurred to less than 70% of the initial level. There was no difference in the results of experiments with or without irradiation. In the 'bag to bag' procedures, no significant change in the blood leukocyte counts including CFU-C, was established.

  4. Assessment guidance of carbohydrate counting method in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Martins, Michelle R; Ambrosio, Ana Cristina T; Nery, Marcia; Aquino, Rita de Cássia; Queiroz, Marcia S

    2014-04-01

    We evaluated the application of the method of carbohydrate counting performed by 21 patients with type 2 diabetes, 1 year later attending a guidance course. Participants answered a questionnaire to assess patients' adhesion to carbohydrate counting as well as to identify habit changes and the method's applicability, and values of glycated hemoglobin were also analyzed. Most participants (76%) were females, and 25% of them had obesity degree III. There was a statistically significant decrease in glycated hemoglobin from 8.42±0.02% to 7.66±0.01% comparing values before and after counseling. We observed that although patients stated that the method was difficult they understood that carbohydrate counting could allow them make choices and have more freedom in their meals; we also verified if they understood accurately how to replace some foods used regularly in their diets and most patients correctly chose replacements for the groups of bread (76%), beans (67%) and noodles (67%). We concluded that participation in the course led to improved blood glucose control with a significant reduction of glycated hemoglobin, better understanding of food groups and the adoption of healthier eating habits. Copyright © 2013 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  5. Effects of Septrin Administration on Blood Cells Parameters in Humans

    African Journals Online (AJOL)

    The results showed that the packed cell volume (PCV), total white blood cell count (WBC), neutrophils and platelets were significantly decreased (p<0.05), especially after 7-10 days of septrin administration, compared to the control values. On the other hand, the reticulocytes, lymphocytes, eosinophils and prothrombin time ...

  6. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  7. A mind you can count on: validating breath counting as a behavioral measure of mindfulness

    Directory of Open Access Journals (Sweden)

    Daniel B Levinson

    2014-10-01

    Full Text Available Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater nonattachment (i.e. less attentional capture by distractors formerly paired with reward. We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  8. Effect of alginate chemical disinfection on bacterial count over gypsum cast.

    Science.gov (United States)

    Haralur, Satheesh B; Al-Dowah, Omir S; Gana, Naif S; Al-Hytham, Abdullah

    2012-05-01

    To evaluate the efficacy of sodium hypochlorite (1 : 10) and iodophor disinfectants on alginate impressions along with their effect on the survived bacterium count on the gypsum cast. Four alginate impression on each dentate patients were made, of which Group I were not washed or disinfected, Group II impressions were merely washed with water, Group III were disinfected by spraying with sodium hypochlorite (1 : 10), Group IV were disinfected with iodophor (1 : 213). Gypsum cast (type III) were made from all the impression. Impressions and gypsum cast were swabbed in mid palatal region for bacterial culture. Bacterial colony counting done after 3 days of incubation at 37℃ in blood agar media. The data obtained was analyzed by one way ANOVA test at a significant difference level of 0.05. Group I and Group II showed significantly more bacteria compared to Group III and Group IV. Bacterial colonies on the alginate impression and gypsum cast in group disinfected with Sodium hypochlorite (1 : 10) were 0.18, 0.82 respectively compared to group treated with iodophor (1 : 213). There was an increase in bacterial count on dental cast compared to source alginate impressions. Sodium hypochlorite (1 : 10) was found to be better disinfectant for alginate impression. There was an indication of increase in number of bacteria from alginate impression to making of dental cast. Additional gypsum cast disinfectant procedures need to be encouraged to completely eliminate cross infection to dental laboratory.

  9. Red cell properties after different modes of blood transportation

    Directory of Open Access Journals (Sweden)

    Asya Makhro

    2016-07-01

    Full Text Available Transportation of blood samples is unavoidable for assessment of specific parameters in blood of patients with rare anemias, blood doping testing or for research purposes. Despite the awareness that shipment may substantially alter multiple parameters, no study of that extend has been performed to assess these changes and optimize shipment conditions to reduce transportation-related artifacts. Here we investigate the changes in multiple parameters in blood of healthy donors over 72 hours of simulated shipment conditions. Three different anticoagulants (K3EDTA, Sodium Heparin and citrate-based CPDA for two temperatures (4oC and room temperature were tested to define the optimal transportation conditions. Parameters measured cover common cytology and biochemistry parameters (complete blood count, hematocrit, morphological examination, red blood cell (RBC volume, ion content and density, membrane properties and stability (hemolysis, osmotic fragility, membrane heat stability, patch-clamp investigations and formation of micro vesicles, Ca2+ handling, RBC metabolism, activity of numerous enzymes and O2 transport capacity. Our findings indicate that individual sets of parameter may require different shipment settings (anticoagulants, temperature. Most of the parameters except for ion (Na+, K+, Ca2+ handling and, possibly, reticulocytes counts, tend to favor transportation at 4oC. Whereas plasma and intraerythrocytic Ca2+ cannot be accurately measured in the presence of chelators such as citrate and EDTA, majority of Ca2+-dependent parameters are stabilized in CPDA samples. Even in blood samples from healthy donors transported using optimized shipment protocol the majority of parameters were stable within 24 hours, the condition that may not hold for the samples of patients with rare anemias. This implies for the as short as possible shipping using fast courier services to the closest expert laboratory at reach. Mobile laboratories or the travel of the

  10. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  11. Peripheral blood cells among community residents living near nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yuan-Teh; Hsu, Hsiu-Ching; Chien, Kuo-Liong; Yang, Chi-Yu; Chen, Wen Jone [Department of Internal Medicine, National Taiwan University College of Medicine, No. 7 Chungshan South Road, 10020 Taipei (Taiwan, Province of China); Sung, Fung C. [Institute of Environmental Health, National Taiwan University College of Public Health, Taipei (Taiwan, Province of China); Lin, Ruey S. [Institute of Epidemiology, National Taiwan University College of Public Health, Taipei (Taiwan, Province of China)

    2001-12-03

    Information about hematopoieses as a result of exposure to very low levels of radiation is scarce. To investigate the human hematopoietic effect of very low level radiation exposure, measurements of peripheral blood components were performed among 3602 men and women, aged 35 and above, living in a community near two nuclear power installations in Chinshan, Taiwan. The radiation level that each individual was exposed to was represented by a surrogate level, '+', a transformed distance from each individual's residence to the two power plants D{sub 1} and D{sub 2}. In addition to comparing average hematology measurements, multiple regression analyses were done to include age, gender, smoking, drinking status and the surrogate radiation exposure level as independent variables. Univariate and bivariate analyses showed that the hematology measurements had significant associations with age, gender, smoking or drinking. The multiple regression analyses revealed that significant positive associations with '+' were found for hemoglobin, hematocrit, platelet, white blood cell and red blood cell. The platelet count might increase for 208.7x10{sup 3}/{mu}l if the exposure from the nuclear plants increased by one exposure unit. This type of association implies that those who lived closer to the nuclear power installation had a higher blood cell count; we suspect that this could be a type of radiation hormesis.

  12. Blood splash from different diathermy instruments during tonsillectomy.

    Science.gov (United States)

    Hanna, B C; Thompson, P; Smyth, C; Gallagher, G

    2006-11-01

    To compare the potential risk of blood contamination of the surgeon's conjunctiva during tonsillectomy using disposable bipolar diathermy and reusable monopolar diathermy. A prospective, single-blind, randomized, controlled trial. Elective tonsillectomy was performed using either disposable bipolar diathermy or reusable monopolar diathermy. The operating surgeon wore a ViewsafeTM protective eyeshield which was later examined under an operating microscope by a blinded observer and the number of blood spots counted. One hundred and sixty-eight patients were enrolled. The relative risk of conjunctival contamination of the surgeon using disposable bipolar diathermy was 2.8 times that with reusable monopolar diathermy (chi-squared test, p blood splatter. The use of disposable bipolar diathermy for haemostasis during tonsillectomy poses a greater risk of conjunctival contamination for the surgeon than using reusable monopolar diathermy.

  13. Blood analysis in newborn donkeys: hematology, biochemistry, and blood gases analysis.

    Science.gov (United States)

    Veronesi, M C; Gloria, A; Panzani, S; Sfirro, M P; Carluccio, A; Contri, A

    2014-07-15

    The knowledge of reference ranges for hematologic, biochemical, and blood gas parameters in the different species and the influence of breed and age on them is a fundamental tool for the clinician. For this reason, the aim of this study was to evaluate the age-related changes of hematologic and biochemical parameters in Martina Franca donkey foals during the first 3 weeks of life and of blood gases during the first 24 hours of age. Fifteen healthy donkey foals were enrolled; blood samples were collected from each foal at 10 minutes after birth, 1 hour after the first and second suckles, 12 and 24 hours after birth, daily from Day 2 to 7, and at Days 10, 14, and 21 of life. Erythrocytes, leukocytes, and platelets counts were assessed; also metabolic (alanine aminotransferase, aspartate aminotransferase, gamma glutamyl transferase, creatinphospokinase, lactate dehydrogenase, alkaline phosphatase, glucose, blood urea nitrogen, creatinine, total proteins, albumins, cholesterol, and total bilirubin) and electrolytic parameters (Ca, P, Mg, Na, K, and Cl) were evaluated. Finally, blood gases and metabolic parameters (pH, pCO2, pO2, sO2, TCO2, HCO3, lactate, and base excess) on venous blood were assessed with a portable analyzer. A statistical analysis to evaluate the influence of age and sex was performed. Several differences were found between sampling times, demonstrating that age influences these parameters. Moreover differences were found compared with data reported in literature for donkey foals of another species, horse foals, and adult donkeys. Although a great interindividual variation for some parameters exists, this study demonstrated that interval references should be addressed not only to different species, but also to specific breeds and to the neonatal period. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Platelet-, leucocyte- and red cell-derived microparticles in stored whole blood, with and without leucofiltration, with and without ionising radiation.

    Science.gov (United States)

    Saito, Shunnichi; Nollet, Kenneth E; Ngoma, Alain M; Ono, Takako; Ohto, Hitoshi

    2018-02-01

    Storage lesion, including microparticle formation, has been partially characterised in whole blood, but not in all combinations of pre-storage leucofiltration and/or irradiation. Single-donor whole blood products were processed into four subunits: with and without leucofiltration, with and without X-irradiation (25 Gy). Platelet-, leucocyte-, and erythrocyte-derived microparticles and free haemoglobin were measured periodically throughout 42 days of storage. Pre-storage leucofiltration substantially reduced platelet- and leucocyte-derived microparticle counts throughout storage. Irradiation, in contrast, had no significant effect on microparticle counts. A gate for all microparticles showed a substantial time-dependent increase in unfiltered whole blood. A time-dependent increase in free haemoglobin was greatest in unfiltered, irradiated whole blood. This study indicates that leucofiltration can prevent the formation of leucocyte- and platelet-derived microparticles, and might reduce haemolysis in irradiated whole blood, either by removing factors that provoke haemolysis, or by selective retention of senescent or effete red cells most prone to haemolysis.

  15. The Effects of Smoking on Platelet Count, Mean Platelet Volume and Cardiovascular Risk Factors: A Case-control Study

    Directory of Open Access Journals (Sweden)

    Ruhuşen Kutlu

    2017-12-01

    Full Text Available Aim: Smoking and cholesterol levels are two important components of atherosclerosis. Mean platelet volume (MPV is an indicator of platelet function and activation and a potential marker of cardiovascular disease. In this study, we aimed to investigate the effects of cigarette-smoking on platelet count, MPV and cardiovascular risk factors. Methods: This research was planned as a case-control study. Patients who attended our family medicine outpatient clinic were included in the study. Sociodemographic characteristics, smoking status, hematological and biochemical parameters of the patients were recorded. Results: The mean age of 880 patients who participated in the study was 35.85±11.6 years (17-77. 54.5% (n=480 of participants were smokers and 45.5% (n=400 were non-smokers. The number of smokers among working individuals was higher than in non-workers. The white blood cell, hemoglobin, hematocrit, red blood cell, mean corpuscular volume and MPV values in the smokers were higher than in the non-smokers, while platelet count was higher in non-smokers (p<0.001. There was a statistically significant relationship between MPV levels and the number of daily cigarette smoking among smokers (p=0.014. Conclusion: MPV levels in smokers were significantly higher than in non-smokers. Platelet count and MPV levels should be investigated in larger patient groups in terms of atherosclerosis and other defined cardiovascular risk factors. It is therefore should take its rightful place in clinical practice.

  16. Oligonol Supplementation Affects Leukocyte and Immune Cell Counts after Heat Loading in Humans

    Directory of Open Access Journals (Sweden)

    Jeong Beom Lee

    2014-06-01

    Full Text Available Oligonol is a low-molecular-weight form of polyphenol and has antioxidant and anti-inflammatory activity, making it a potential promoter of immunity. This study investigates the effects of oligonol supplementation on leukocyte and immune cell counts after heat loading in 19 healthy male volunteers. The participants took a daily dose of 200 mg oligonol or a placebo for 1 week. After a 2-week washout period, the subjects were switched to the other study arm. After each supplement, half-body immersion into hot water was made, and blood was collected. Then, complete and differential blood counts were performed. Flow cytometry was used to enumerate and phenotype lymphocyte subsets. Serum concentrations of interleukin (IL-1β and IL-6 in blood samples were analyzed. Lymphocyte subpopulation variables included counts of total T cells, B cells, and natural killer (NK cells. Oligonol intake attenuated elevations in IL-1β (an 11.1-fold change vs. a 13.9-fold change immediately after heating; a 12.0-fold change vs. a 12.6-fold change 1h after heating and IL-6 (an 8.6-fold change vs. a 9.9-fold change immediately after heating; a 9.1-fold change vs. a 10.5-fold change 1h after heating immediately and 1 h after heating in comparison to those in the placebo group. Oligonol supplementation led to significantly higher numbers of leukocytes (a 30.0% change vs. a 21.5% change immediately after heating; a 13.5% change vs. a 3.5% change 1h after heating and lymphocytes (a 47.3% change vs. a 39.3% change immediately after heating; a 19.08% change vs. a 2.1% change 1h after heating relative to those in the placebo group. Oligonol intake led to larger increases in T cells, B cells, and NK cells at rest (p < 0.05, p < 0.05, and p < 0.001, respectively and immediately after heating (p < 0.001 in comparison to those in the placebo group. In addition, levels of T cells (p < 0.001 and B cells (p < 0.001 were significantly higher 1 h after heating in comparison to those in

  17. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, S

    2015-02-01

    Full Text Available and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow as well as color-based segmentation of the different fluids using a hue...

  18. Large-Scale Exome-wide Association Analysis Identifies Loci for White Blood Cell Traits and Pleiotropy with Immune-Mediated Diseases

    NARCIS (Netherlands)

    Tajuddin, S.M. (Salman M.); U.M. Schick (Ursula); Eicher, J.D. (John D.); Chami, N. (Nathalie); Giri, A. (Ayush); J. Brody (Jennifer); W.D. Hill (W. David); T. Kacprowski (Tim); Li, J. (Jin); L.-P. Lyytikäinen (Leo-Pekka); A. Manichaikul (Ani); E. Mihailov (Evelin); M.L. O'Donoghue (Michelle L.); V.S. Pankratz (Shane); R. Pazoki (Raha); Polfus, L.M. (Linda M.); A.V. Smith (Albert Vernon); C. Schurmann (Claudia); Vacchi-Suzzi, C. (Caterina); D. Waterworth (Dawn); E. Evangelou (Evangelos); L.R. Yanek (Lisa); A.D. Burt (Alastair); M.-H. Chen (Ming-Huei); F.J.A. van Rooij (Frank); J. Floyd (James); A. Greinacher (Andreas); T.B. Harris (Tamara); H. Highland (Heather); L.A. Lange (Leslie); Y. Liu (YongMei); R. Mägi (Reedik); M.A. Nalls (Michael); J. Mathias (Jasmine); D.A. Nickerson (Deborah); K. Nikus (Kjell); J.M. Starr (John); J.-C. Tardif (Jean-Claude); I. Tzoulaki; Velez Edwards, D.R. (Digna R.); L.C. Wallentin (Lars); T.M. Bartz (Traci M.); L.C. Becker (Lewis); Denny, J.C. (Joshua C.); Raffield, L.M. (Laura M.); J.D. Rioux (John); N. Friedrich (Nele); M. Fornage (Myriam); Gao, H. (He); J.N. Hirschhorn (Joel); D.C. Liewald (David C.); S.S. Rich (Stephen); A.G. Uitterlinden (André); Bastarache, L. (Lisa); D.M. Becker (Diane); E.A. Boerwinkle (Eric); de Denus, S. (Simon); E.P. Bottinger (Erwin); C. Hayward (Caroline); Hofman, A. (Albert); G. Homuth (Georg); E.M. Lange (Ethan); Launer, L.J. (Lenore J.); T. Lehtimäki (Terho); Y. Lu (Yingchang); A. Metspalu (Andres); C.J. O'Donnell (Christopher); Quarells, R.C. (Rakale C.); Richard, M. (Melissa); Torstenson, E.S. (Eric S.); K.D. Taylor (Kent); Vergnaud, A.-C. (Anne-Claire); A.B. Zonderman; D.R. Crosslin (David); I.J. Deary (Ian J.); M. Dörr (Marcus); P. Elliott (Paul); M. Evans (Michele); V. Gudnason (Vilmundur); M. Kähönen (Mika); B.M. Psaty (Bruce); Rotter, J.I. (Jerome I.); Slater, A.J. (Andrew J.); A. Dehghan (Abbas); White, H.D. (Harvey D.); S.K. Ganesh (Santhi); R.J.F. Loos (Ruth); T. Esko (Tõnu); Faraday, N. (Nauder); J.F. Wilson (James); M. Cushman (Mary Ann); A.D. Johnson (Andrew); T.L. Edwards (Todd L.); N.A. Zakai (Neil); G. Lettre (Guillaume); A. Reiner (Alexander); P. Auer (Paul)

    2016-01-01

    textabstractWhite blood cells play diverse roles in innate and adaptive immunity. Genetic association analyses of phenotypic variation in circulating white blood cell (WBC) counts from large samples of otherwise healthy individuals can provide insights into genes and biologic pathways involved in

  19. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  20. Blood gases, biochemistry, and hematology of Galapagos green turtles (Chelonia mydas.

    Directory of Open Access Journals (Sweden)

    Gregory A Lewbart

    Full Text Available The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site. Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature. A portable blood analyzer (iSTAT was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3-, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1 with standard formulas; and (2 with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease.

  1. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  2. Effect of an Arctium lappa (burdock) extract on the labeling of blood constituents with technetium-99m and on the morphology of the red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Neves, Rosane de Figueiredo; Rebello, Bernardo Machado; Medeiros, Aldo da Cunha [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil). Programa de Pos-graduacao em Ciencias da Saude]. E-mail: nevesrosane@yahoo.com.br; Moreno, Silvana Ramos Farias; Fonseca, Adenilson de Souza da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Caldas, Luiz Querino de Araujo [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Programa de Pos-Graduacao em Ciencias Medicas; Bernardo-Filho, Mario [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil). Coordenadoria de Pesquisa

    2007-09-15

    Arctium lappa (burdock) has been used to treat inflammatory processes. Blood constituents labeled with technetium-99m ({sup 99m}Tc) have been utilized in nuclear medicine. It was evaluated the influence of a burdock extract on the labeling of blood constituents with {sup 99m}Tc and on the morphometry of red blood cells. Blood samples from Wistar rats were incubated with burdock extract and the radiolabeling procedure was carried out. Plasma and blood cells, soluble and insoluble fractions of plasma and blood cells were separated. The radioactivity in each fraction was counted and the percentages of radioactivity (%ATI) were determined. Morphology and morphometric (perimeter/area ratio) measurements of red blood cells (RBC) were performed. The incubation with burdock extract significantly (p<0.05) altered the %ATI on the blood compartments and the perimeter/area ratio of RBC, as well as, induced modifications on the shape of RBC. Alterations on membrane could justify the decrease of labeling of blood cells with {sup 99m}Tc obtained in this study. (author)

  3. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  4. Heterogeneity in white blood cells has potential to confound DNA methylation measurements.

    Directory of Open Access Journals (Sweden)

    Bjorn T Adalsteinsson

    Full Text Available Epigenetic studies are commonly conducted on DNA from tissue samples. However, tissues are ensembles of cells that may each have their own epigenetic profile, and therefore inter-individual cellular heterogeneity may compromise these studies. Here, we explore the potential for such confounding on DNA methylation measurement outcomes when using DNA from whole blood. DNA methylation was measured using pyrosequencing-based methodology in whole blood (n = 50-179 and in two white blood cell fractions (n = 20, isolated using density gradient centrifugation, in four CGIs (CpG Islands located in genes HHEX (10 CpG sites assayed, KCNJ11 (8 CpGs, KCNQ1 (4 CpGs and PM20D1 (7 CpGs. Cellular heterogeneity (variation in proportional white blood cell counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils, counted by an automated cell counter explained up to 40% (p<0.0001 of the inter-individual variation in whole blood DNA methylation levels in the HHEX CGI, but not a significant proportion of the variation in the other three CGIs tested. DNA methylation levels in the two cell fractions, polymorphonuclear and mononuclear cells, differed significantly in the HHEX CGI; specifically the average absolute difference ranged between 3.4-15.7 percentage points per CpG site. In the other three CGIs tested, methylation levels in the two fractions did not differ significantly, and/or the difference was more moderate. In the examined CGIs, methylation levels were highly correlated between cell fractions. In summary, our analysis detects region-specific differential DNA methylation between white blood cell subtypes, which can confound the outcome of whole blood DNA methylation measurements. Finally, by demonstrating the high correlation between methylation levels in cell fractions, our results suggest a possibility to use a proportional number of a single white blood cell type to correct for this confounding effect in analyses.

  5. Noninvasive regional cerebral blood flow measurements at pre- and post-acetazolamide test using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Nakano, Seigo; Tanaka, Masaaki.

    1996-01-01

    A technique for serial noninvasive cerebral blood flow measurements at pre- and post-acetazolamide (Diamox) test was newly developed using 99m Tc-ECD without blood sampling. Baseline mean cerebral blood flow (mCBF) was measured from graphical analysis of time activity curves for brain and aortic arch obtained from radionuclide angiography by injection of 370-555 MBq 99m Tc-ECD. The first SPECT study was performed immediately after intravenous administration of 1 g of Diamox, then baseline regional cerebral blood flow (rCBF) was calculated using Lassen's correction algorithm. Immediately after the stop of the first SPECT study, additional 555-740 MBq of 99m Tc-ECD was administered, thereafter the second SPECT study was started. Post-Diamox SPECT images were obtained by subtraction of the first baseline images from the second images. Using Lassen's algorithm, post-Diamox mCBF was estimated from the baseline mCBF, the baseline mean SPECT counts, and post-Diamox mean SPECT counts corrected for administered dose and imaging time. Post-Diamox rCBF was obtained from the post-Diamox mCBF and the post-Diamox mean SPECT counts using Lassen's algorithm. Coefficient variation was shown 2.7% and 3.5%: mCBF and rCBF, respectively in test-retest results in six patients without Diamox administration. Nine demented patients without vascular disorders showed significant mCBF increase of 35.7% on the average by post-Diamox. In conclusion, this simplified method is practically useful for measuring CBF at pre- and post-Diamox test within short period of time without any blood sample. (author)

  6. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  7. Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow.

    Science.gov (United States)

    Renaud, Jennifer M; Yip, Kathy; Guimond, Jean; Trottier, Mikaël; Pibarot, Philippe; Turcotte, Eric; Maguire, Conor; Lalonde, Lucille; Gulenchyn, Karen; Farncombe, Troy; Wisenberg, Gerald; Moody, Jonathan; Lee, Benjamin; Port, Steven C; Turkington, Timothy G; Beanlands, Rob S; deKemp, Robert A

    2017-01-01

    Three-dimensional (3D) mode imaging is the current standard for PET/CT systems. Dynamic imaging for quantification of myocardial blood flow with short-lived tracers, such as 82 Rb-chloride, requires accuracy to be maintained over a wide range of isotope activities and scanner counting rates. We proposed new performance standard measurements to characterize the dynamic range of PET systems for accurate quantitative imaging. 82 Rb or 13 N-ammonia (1,100-3,000 MBq) was injected into the heart wall insert of an anthropomorphic torso phantom. A decaying isotope scan was obtained over 5 half-lives on 9 different 3D PET/CT systems and 1 3D/2-dimensional PET-only system. Dynamic images (28 × 15 s) were reconstructed using iterative algorithms with all corrections enabled. Dynamic range was defined as the maximum activity in the myocardial wall with less than 10% bias, from which corresponding dead-time, counting rates, and/or injected activity limits were established for each scanner. Scatter correction residual bias was estimated as the maximum cavity blood-to-myocardium activity ratio. Image quality was assessed via the coefficient of variation measuring nonuniformity of the left ventricular myocardium activity distribution. Maximum recommended injected activity/body weight, peak dead-time correction factor, counting rates, and residual scatter bias for accurate cardiac myocardial blood flow imaging were 3-14 MBq/kg, 1.5-4.0, 22-64 Mcps singles and 4-14 Mcps prompt coincidence counting rates, and 2%-10% on the investigated scanners. Nonuniformity of the myocardial activity distribution varied from 3% to 16%. Accurate dynamic imaging is possible on the 10 3D PET systems if the maximum injected MBq/kg values are respected to limit peak dead-time losses during the bolus first-pass transit. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Equivalence of truncated count mixture distributions and mixtures of truncated count distributions.

    Science.gov (United States)

    Böhning, Dankmar; Kuhnert, Ronny

    2006-12-01

    This article is about modeling count data with zero truncation. A parametric count density family is considered. The truncated mixture of densities from this family is different from the mixture of truncated densities from the same family. Whereas the former model is more natural to formulate and to interpret, the latter model is theoretically easier to treat. It is shown that for any mixing distribution leading to a truncated mixture, a (usually different) mixing distribution can be found so that the associated mixture of truncated densities equals the truncated mixture, and vice versa. This implies that the likelihood surfaces for both situations agree, and in this sense both models are equivalent. Zero-truncated count data models are used frequently in the capture-recapture setting to estimate population size, and it can be shown that the two Horvitz-Thompson estimators, associated with the two models, agree. In particular, it is possible to achieve strong results for mixtures of truncated Poisson densities, including reliable, global construction of the unique NPMLE (nonparametric maximum likelihood estimator) of the mixing distribution, implying a unique estimator for the population size. The benefit of these results lies in the fact that it is valid to work with the mixture of truncated count densities, which is less appealing for the practitioner but theoretically easier. Mixtures of truncated count densities form a convex linear model, for which a developed theory exists, including global maximum likelihood theory as well as algorithmic approaches. Once the problem has been solved in this class, it might readily be transformed back to the original problem by means of an explicitly given mapping. Applications of these ideas are given, particularly in the case of the truncated Poisson family.

  9. Blood indicators of seasonal metabolic patterns in captive adult gray wolves

    Science.gov (United States)

    Seal, U.S.; Mech, L.D.

    1983-01-01

    Blood samples and physical data were collected weekly from a colony of gray wolves (Canis lupus) maintained under natural weather arid light conditions. Sampling over 33 continuous months indicated that hemoglobin, hematocrit, red blood cells, mean corpuscular hemoglobin concentration (MCHC), and thyroxine exhibited consistent circannual patterns of variation in both males and females. Hemoglobin levels peaked at 15-16 g/dl in January in females and at 16-17 g/dl in February in males, and were lowest in August at 10.5-11.5 g/dl (P patterns of hematocrit, red blood cells, and MCHC were similarly timed. Females also had a cyclic pattern of white blood cell counts and body weight; their weight peaked in early February and was lowest in August (P pattern.

  10. Acute effects of resistance exercise and intermittent intense aerobic exercise on blood cell count and oxidative stress in trained middle-aged women.

    Science.gov (United States)

    Cardoso, A M; Bagatini, M D; Roth, M A; Martins, C C; Rezer, J F P; Mello, F F; Lopes, L F D; Morsch, V M; Schetinger, M R C

    2012-12-01

    The aim of this study was to compare the effect of an intermittent intense aerobic exercise session and a resistance exercise session on blood cell counts and oxidative stress parameters in middle-aged women. Thirty-four women were selected and divided into three groups: RE group (performing 60 min of resistance exercises, N = 12), spinning group (performing 60 min of spinning, N = 12), and control group (not exercising regularly, N = 10). In both exercise groups, lymphocytes and monocytes decreased after 1-h recuperation (post-exercise) compared to immediately after exercise (P exercise, in both exercised groups, a significant increase in TBARS (from 16.5 ± 2 to 25 ± 2 for the spinning group and from 18.6 ± 1 to 28.2 ± 3 nmol MDA/mL serum for the RE group) and protein carbonyl (from 1.0 ± 0.3 to 1.6 ± 0.2 for the spinning group and from 0.9 ± 0.2 to 1.5 ± 0.2 nmol/mg protein for the RE group) was observed (P exercise induces immune suppression and increases the production of reactive oxygen species, causing oxidative stress in middle-aged and trained women. Furthermore, we demonstrated that trained women show improved antioxidant capacity and lower oxidative damage than sedentary ones, demonstrating the benefits of chronic regular physical activity.

  11. Reduced bacterial colony count of anaerobic bacteria is associated with a worsening in lung clearance index and inflammation in cystic fibrosis.

    Science.gov (United States)

    O'Neill, Katherine; Bradley, Judy M; Johnston, Elinor; McGrath, Stephanie; McIlreavey, Leanne; Rowan, Stephen; Reid, Alastair; Bradbury, Ian; Einarsson, Gisli; Elborn, J Stuart; Tunney, Michael M

    2015-01-01

    Anaerobic bacteria have been identified in abundance in the airways of cystic fibrosis (CF) subjects. The impact their presence and abundance has on lung function and inflammation is unclear. The aim of this study was to investigate the relationship between the colony count of aerobic and anaerobic bacteria, lung clearance index (LCI), spirometry and C-Reactive Protein (CRP) in patients with CF. Sputum and blood were collected from CF patients at a single cross-sectional visit when clinically stable. Community composition and bacterial colony counts were analysed using extended aerobic and anaerobic culture. Patients completed spirometry and a multiple breath washout (MBW) test to obtain LCI. An inverse correlation between colony count of aerobic bacteria (n = 41, r = -0.35; p = 0.02), anaerobic bacteria (n = 41, r = -0.44, p = 0.004) and LCI was observed. There was an inverse correlation between colony count of anaerobic bacteria and CRP (n = 25, r = -0.44, p = 0.03) only. The results of this study demonstrate that a lower colony count of aerobic and anaerobic bacteria correlated with a worse LCI. A lower colony count of anaerobic bacteria also correlated with higher CRP levels. These results indicate that lower abundance of aerobic and anaerobic bacteria may reflect microbiota disruption and disease progression in the CF lung.

  12. Radiation effects in blood used for the in vitro feeding of tsetse flies

    Energy Technology Data Exchange (ETDEWEB)

    Hamann, H J [Gesellschaft fuer Strahlen- und Umweltforschung m.b.H. Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenbotanink; Bickhardt, K [Tieraerztliche Hochschule Hannover (Germany, F.R.)

    1983-05-01

    Freshly collected and ..gamma..-sterilized (dose 100 krad) pig's blood, usually fed to tsetse flies, was tested for radiation induced changes of the following parameters: count of red cells and leucocytes; differential count of white cells; haematocrit ratio; concentrations of haemoglobin, protein, glucose and lactate in the serum; activities of glutamate-oxalacetate transaminase and creatine kinase. The tests were performed on the day of irradiation and, after storage at 4/sup 0/C, two and seven days later. Unequivocal radiation damage was observed in the case of haematocrit value, erythrocyte count and creatine kinase activity. The concentration of glucose and lactate are not influenced by the irradiation but only by the time elapsed.

  13. Quantitative assessment of postoperative blood collection in brain tumor surgery under valproate medication.

    Science.gov (United States)

    Psaras, T; Will, B E; Schoeber, W; Rona, S; Mittelbronn, M; Honegger, J B

    2008-11-01

    The aim of the study was to evaluate whether valproate (VPA) increases the risk of bleeding complications in patients undergoing brain tumor surgery. A retrospective chart review of 85 patients operated on between January and December 2005 was performed. 19 patients received VPA, 22 patients were given other anti-epileptic drugs (AEDs), 44 patients received no AEDs. Data analyzed included intraoperative blood loss, transfusion, important comorbidity factors and concomitant diseases. Preoperative and postoperative laboratory data included hemoglobin, hematocrit, fibrinogen, platelet count, INR, prothrombin time, partial thromboplastin time and RBC count. The tumor volume was evaluated by preoperative MRI and CT scans of the brain. All 85 patients underwent a native CT scan of the brain on the first day after the operation. The volume of the resection cavity and the volume of blood were documented. We could show that the volume of the tumor had a significant effect on the amount of blood in the tumor cavity, whereas VPA medication had no effect. In our dataset, we found that tumor size had a significant effect on postoperative blood volume. In contrast, no serious bleeding complications occurred in the patients receiving VPA. Therefore, the present study does not provide any evidence for the need to discontinue VPA medication prior to and during surgery.

  14. Differential associations between white blood cell counts and fatigue in young and older adults

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Hokland, Marianne; Mehlsen, Mimi Yung

    2012-01-01

    The aims of this exploratory study were to study whether fatigue might be related to the cellular immune system by 1) analysing if the number of white blood cell subsets are related to fatigue and 2) if possible relationships vary in younger and older community-dwelling individuals....

  15. Correction for decay during counting in gamma spectrometry

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2013-01-01

    A basic result in gamma spectrometry is the count rate of a relevant peak. Correction for decay during counting and expressing the count rate at the beginning of the measurement can be done by a multiplicative factor that is derived from integrating the count rate over time. The counting time substituted in this factor must be the live time, whereas the use of the real-time is an error that underestimates the count rate by about the dead-time (DT) (in percentage). This error of underestimation of the count rate is corroborated in the measurement of a nuclide with a high DT. The present methodology is not applicable in systems that include a zero DT correction function. (authors)

  16. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  17. Population-based CD4 counts in a rural area in South Africa with high HIV prevalence and high antiretroviral treatment coverage.

    Directory of Open Access Journals (Sweden)

    Abraham Malaza

    Full Text Available Little is known about the variability of CD4 counts in the general population of sub-Saharan Africa countries affected by the HIV epidemic. We investigated factors associated with CD4 counts in a rural area in South Africa with high HIV prevalence and high antiretroviral treatment (ART coverage.CD4 counts, health status, body mass index (BMI, demographic characteristics and HIV status were assessed in 4990 adult resident participants of a demographic surveillance in rural KwaZulu-Natal in South Africa; antiretroviral treatment duration was obtained from a linked clinical database. Multivariable regression analysis, overall and stratified by HIV status, was performed with CD4 count levels as outcome.Median CD4 counts were significantly higher in women than in men overall (714 vs. 630 cells/µl, p<0.0001, both in HIV-uninfected (833 vs. 683 cells/µl, p<0.0001 and HIV-infected adults (384.5 vs. 333 cells/µl, p<0.0001. In multivariable regression analysis, women had 19.4% (95% confidence interval (CI 16.1-22.9 higher CD4 counts than men, controlling for age, HIV status, urban/rural residence, household wealth, education, BMI, self-reported tuberculosis, high blood pressure, other chronic illnesses and sample processing delay. At ART initiation, HIV-infected adults had 21.7% (95% CI 14.6-28.2 lower CD4 counts than treatment-naive individuals; CD4 counts were estimated to increase by 9.2% (95% CI 6.2-12.4 per year of treatment.CD4 counts are primarily determined by sex in HIV-uninfected adults, and by sex, age and duration of antiretroviral treatment in HIV-infected adults. Lower CD4 counts at ART initiation in men could be a consequence of lower CD4 cell counts before HIV acquisition.

  18. Total lymphocyte count as a substitute to cd4 count in management of hiv infected individuals in resource limited society

    International Nuclear Information System (INIS)

    Daud, M.Y.; Qazi, R.A.

    2015-01-01

    Pakistan is a resource limited society and gold standard parameters to monitor HIV disease activity are very costly. The objective of the study was to evaluate total lymphocyte count (TLC) as a surrogate to CD4 count to monitor disease activity in HIV/AIDS in resource limited society. Methods: This cross sectional study was carried out at HIV/AIDS treatment centre, Pakistan Institute of Medical Sciences (PIMS), Islamabad. A total of seven hundred and seventy four (774) HIV positive patients were enrolled in this study, and their CD4 count and total lymphocyte count were checked to find any correlation between the two by using Spearman ranked correlation coefficient. Results: The mean CD4 count was (434.30 ± 269.23), with minimum CD4 count of (9.00), and maximum of (1974.00). The mean total lymphocyte count (TLC) was (6764.0052 ± 2364.02) with minimum TLC (1200.00) and maximum TLC was (20200.00). Using the Pearson's correlation (r) there was a significant and positive correlation between TLC and CD4 count. (r2=0.127 and p=0.000) at 0.01 level. Conclusion: Our study showed a significant positive correlation between CD4 count and total lymphocyte count (TLC), so TLC can be used as a marker of disease activity in HIV infected patients. (author)

  19. Dietary value of honey and it effects on abdominal fat deposit, blood ...

    African Journals Online (AJOL)

    Journal of Agriculture, Forestry and the Social Sciences ... The haematological formations of Packed cell volume, Red blood cell, Haemoglobin and serum biochemical components (serum protein, albumin and creatinines) of birds improved with increasing dietary honey inclusion, while the WBC and its differential counts ...

  20. Evaluation of factor for one-point venous blood sampling method based on the causality model

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Onishi, Hideo; Kobara, Kouichi; Sasaki, Fumie; Watanabe, Haruo; Nagaki, Akio; Mimura, Hiroaki

    2009-01-01

    One-point venous blood sampling method (Mimura, et al.) can evaluate the regional cerebral blood flow (rCBF) value with a high degree of accuracy. However, the method is accompanied by complexity of technique because it requires a venous blood Octanol value, and its accuracy is affected by factors of input function. Therefore, we evaluated the factors that are used for input function to determine the accuracy input function and simplify the technique. The input function which uses the time-dependent brain count of 5 minutes, 15 minutes, and 25 minutes from administration, and the input function in which an objective variable is used as the artery octanol value to exclude the venous blood octanol value are created. Therefore, a correlation between these functions and rCBF value by the microsphere (MS) method is evaluated. Creation of a high-accuracy input function and simplification of technique are possible. The rCBF value obtained by the input function, the factor of which is a time-dependent brain count of 5 minutes from administration, and the objective variable is artery octanol value, had a high correlation with the MS method (y=0.899x+4.653, r=0.842). (author)

  1. A counting-card circuit based on PCI bus

    International Nuclear Information System (INIS)

    Shi Jing; Li Yong; Chinese Academy of Sciences, Lanzhou; Su Hong; Dong Chengfu; Li Xiaogang; Ma Xiaoli

    2004-01-01

    A counting-card circuit based on PCI bus that we developed recently used for advanced personal computer will be introduced in this paper briefly. The maximum count capacity of this counting-card is 10 9 -1, ranging from 0 to 999 999 999, the maximum counting time range, 1 x 10 6 s, can be set in 1 cycle, the maximum counting rate is 20 MHz for positive input. (authors)

  2. A ppendicitis with Positive Ultrasound and its Relation to Total and Differential Leucocytic Count

    International Nuclear Information System (INIS)

    Saleh, G.M.; Sabek, E.A.S.; Elessiely, E.S.; Ibrahim, E.M.

    2016-01-01

    Background:The most common cause of acute surgical abdomen is acute appendicitis and the most commonly done emergency surgery is appendectomy. Although a battery of tests and different scoring methods are available for diagnosis of acute appendicitis, it is very difficult to prevent negative explorations for appendicectomy (15 - 30%). None of the tests has satisfactory Sensitivity and specificity that can be relied upon. Objectives: The aim of the present study was to evaluate the role of total and differential leukocyte count, and ultrasonography (USG) of abdomen in diagnosing acute appendicitis and reducing the rates of negative appendicectomies and to prevent complications like perforation, peritonitis, and the longer the delay between diagnosis and surgery, the more likely is the perforation leading to peritonitis. In addition, emphasis was given to whether combining the investigations for the same patient would improve the diagnostic accuracy. Materials and Methods : A total of 76 clinically diagnosed patients of acute appendicitis, posted for emergency appendicectomy were included in the study in General Surgery Department of EL-Salam Hospital. This study was conducted in the period October 2012 to September 2013. Preoperatively blood tests for, total leukocyte count, differential leukocyte count(DLC) and USG abdomen were done. All patients were subjected to histological examination postoperatively, which was taken as the gold standard. The three investigations results were correlated with histopathological examination reports to evaluate their role in diagnosis of acute appendicitis. Results: In the present study, the US has the highest sensitivity and specificity (90%, 80%) followed by Total leucocyte count (87.5%, 90%), white Neutrophil count (78.75%, 80%). Combining US and WBC count increases the sensitivity and specificity of the tests (96.25%, 80%). Conclusion: US contains important diagnostic information and hence should always be included in the

  3. HEMATOPOIETIC PROGENITOR CELLS AS A PREDICTIVE OF CD34+ ENUMERATION PRIOR TO PERIPHERAL BLOOD STEM CELLS HARVESTING

    Directory of Open Access Journals (Sweden)

    Z. Zulkafli

    2014-09-01

    Full Text Available Background: To date, the CD34+ cell enumeration has relied predominantly on flow cytometry technique. However, flow cytometry is time consuming and operator dependent. The application of the hematopoietic progenitor cells (HPCs channel in Sysmex XE-2100, a fully automated hematology analyzer offers an alternative approach, which is with minimal sample manipulation and less operator dependent. This study evaluates the utility of HPC counts as a predictive of CD34+ enumeration prior to peripheral blood stem cells harvesting. Materials and methods: HPC, CD34+, white blood cell (WBC, reticulocytes (retic, immature platelet fraction (IPF and immature reticulocyte fraction (IRF were determined in 61 samples from 19 patients with hematological malignancies (15 lymphoma and 4 multiple myeloma patients at Hospital Universiti Sains Malaysia (Hospital USM who had received granulocyte-colony stimulating factor (G-CSF and planned for autologous transplantation. Results: CD34+ count showed strong and significant correlation with HPC. The receiver operating characteristics (ROC curve analysis revealed that HPC count > 21.5 x 106 / L can predicts a pre harvest CD34+ count of >20 x 106 / L with sensitivity of 77%, specificity of 64% and area under the curve (AUC of 0.802. Conclusion: We concluded that HPC count can be a useful potential parameter in optimizing timing for CD34+ enumeration prior to leukapheresis.

  4. Radionuclide detection of blood-retinal barrier disruption in diabetes mellitus

    International Nuclear Information System (INIS)

    Freeman, M.L.; Barnes, W.E.; Eastman, G.; Evans, L.; Gergans, G.; Kelertas, A.; Emanuele, N.; Kaplan, E.

    1984-01-01

    Diabetic retinopathy is one of the leading causes of blindness in the United States today. Because early treatment of proliferative retinopathy offers the best chance for visual salvation, there is an essential need for methods of identifying eyes at high risk. Recent research has shown that subclinical leakage from retinal blood vessels is one of the earliest signs of retinopathy. The feasibility of using radionuclide techniques to quantitate blood-retinal barrier disruption is demonstrated by a study in which 23 diabetics and 7 nondiabetics were imaged with an Anger camera in the anterior Waters projection at 2 hours after the administration of Tc-99m DTPA. In the digitized images, regions of interest were placed over each orbit and over one of the cerebral hemispheres. Orbital counts were then compared to cerebral counts on a per pixel basis. Eye to brain ratios were found to be lowest for nondiabetics and highest for patients with proliferative retinopathy. Additionally, the dynamic analysis of the same radiopharmaceutical may allow investigators to further study the pathophysiology of the diabetic eye

  5. Association of asymptomatic oral candidal carriage, oral candidiasis and CD4 lymphocyte count in HIV-positive patients in China.

    Science.gov (United States)

    Liu, X; Liu, H; Guo, Z; Luan, W

    2006-01-01

    To compare the prevalence of asymptomatic oral candidal carriage in healthy volunteers with human immunodeficiency virus (HIV)-positive patients in China, as well as to investigate the relationship between CD4+ lymphocyte count and oral candidal colonization or oral candidiasis. Oral candidal carriage and oral candidiasis were investigated in 101 patients with HIV-infection seen at Youan Hospital, Beijing, China. Two hundred and seventeen healthy volunteers were involved as a control. Culture from saliva was used to test for the presence of oral Candida. CD4+ lymphocyte count was measured by flow cytometry. All data were analyzed statistically by SAS. Asymptomatic oral candidal carriage rate (28.6%) in HIV-positive group was similar to that in the healthy group (18.0%; P = 0.07). No significant difference in CD4+ lymphocyte count was found between oral Candida carriers and non-carriers among HIV-positive subjects (P = 0.89). However, the frequency of oral candidiasis increased with the decrease in CD4+ lymphocyte count (P < 0.0001), and pseudomembranous candidiasis was predominant in HIV-positive patients with CD4+ <200 cells microl(-1) (66.7%). In HIV-positive subjects, asymptomatic oral candidal colonization is not related to CD4+ lymphocyte count of blood, and the carriage rate is similar to that in the healthy population. Oral candidiasis is more likely to be observed in HIV-positive patients who have a low CD4+ lymphocyte count.

  6. Accuracy of Automated Flow Cytometry-Based Leukocyte Counts To Rule Out Urinary Tract Infection in Febrile Children: a Prospective Cross-Sectional Study

    Science.gov (United States)

    Duong, Hong Phuoc; Wissing, Karl Martin; Tram, Nathalie; Mascart, Georges; Lepage, Philippe

    2016-01-01

    Automated flow cytometry of urine remains an incompletely validated method to rule out urinary tract infection (UTI) in children. This cross-sectional analytical study was performed to compare the predictive values of flow cytometry and a dipstick test as initial diagnostic tests for UTI in febrile children and prospectively included 1,106 children (1,247 episodes). Urine culture was used as the gold standard test for diagnosing UTI. The performance of screening tests to diagnose UTI were established using receiver operating characteristic (ROC) analysis. Among these 1,247 febrile episodes, 221 UTIs were diagnosed (17.7% [95% confidence interval {CI}, 15.6 to 19.8%]). The area under the ROC curve for flow cytometry white blood cell (WBC) counts (0.99 [95% CI, 0.98 to 0.99]) was significantly superior to that for red blood cell (0.74 [95% CI, 0.70 to 0.78]) and bacterial counts (0.89 [95% CI, 0.87 to 0.92]) (P UTI in febrile children. PMID:27682127

  7. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    Energy Technology Data Exchange (ETDEWEB)

    Liang, A K; Koniczek, M; Antonuk, L E; El-Mohri, Y; Zhao, Q [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailed circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit

  8. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  9. Association of Blood and Seminal Plasma Cadmium and Lead Levels With Semen Quality in Non-Occupationally Exposed Infertile Men in Abakaliki, South East Nigeria

    Directory of Open Access Journals (Sweden)

    Ademola C Famurewa

    2017-10-01

    Full Text Available Objective: To evaluate association of blood and seminal plasma lead and cadmium with sperm quality of non-occupationally exposed male partners of couples with infertility.Materials and methods: A cross-sectional study was conducted on 75 men aged 20-45 years (mean = 37.1 ± 7.0 yrs. with infertility recruited from the Fertility Clinic of a hospital in Abakaliki. Sperm count done in accordance with the WHO guidelines was used to classify the participants as normospamia, oligospermia and azospermia. Atomic absorption spectrophotometer was used to determine lead and cadmium levels in plasma from blood and semen.Results: There were 15 azospermics, 22 oligospermics and 36 normospermics. Seminal and blood plasma cadmium as well as blood plasma lead were significantly (p < 0.01 higher in azospermic and oligospermic men compared to normospermic men. However, while seminal plasma lead was significantly (p < 0.05 higher in oligospermic and normospernic men than in azospermic men, the seminal plasma lead was comparable between oligospermic and normospermic men. Significant inverse associations (p < 0.01 were found between blood and seminal cadmium levels and sperm count, motility and morphology; blood lead was inversely correlated with sperm count only.Conclusion: The study suggests that environmental exposure to cadmium and lead may contribute to development of poor sperm quality and infertility in men of reproductive age in Nigeria.

  10. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  11. Handling low hemoglobin and iron deficiency in a blood donor population

    DEFF Research Database (Denmark)

    Magnussen, Karin; Ladelund, Steen

    2016-01-01

    BACKGROUND: Iron deficiency and blood donors with low hemoglobin (Hb) concentration are well-known challenges in any blood bank setting. In the Capital Region of Denmark, a new approach was adopted that centralized measurement of Hb, initiated ferritin (F) measurement, and established a center......: The change in Hb for repeat donors was followed during the first 2 years of the intervention strategy, which included measurements of F and offering intermittent iron supplementation to some of the donors. RESULTS: In 2 years, 62,663 blood donors donated 193,288 units of blood and 318 donors gave 754...... complete blood count blood samples. Over time in the repeat donors, the Hb increased from 15.39 to 15.60 g/dL and 13.85 to 14.06 g/dL in male and female donors, respectively, and the proportion of donors with low Hb decreased from 0.9% to 0.3% and 3.9% to 2.7% for the male and female donors, respectively...

  12. Survival and function of phagocytes in blood culture media

    DEFF Research Database (Denmark)

    Fischer, T K; Prag, J; Kharazmi, A

    1999-01-01

    The survival and function of human phagocytes in sterile aerobic and anaerobic blood culture media were investigated using neutrophil morphology, white blood cell count in a haemoanalyser, flow cytometry, oxidative burst response, and bactericidal effect in Colorbact and Septi-Chek blood culture...... media and Bact/Alert. When comparing agitation to stationary incubation no difference in phagocytic activity was found. The methods showed the same trends demonstrating that the phagocytes' viability and activity were prolonged by oxygen and shortened by anaerobic conditions and sodium polyethanol...... sulfonate (SPS). Best preserved activity and viability were found in the aerobic media containing less than 0.5 g/l SPS, in which significant phagocyte oxidative burst and bactericidal activity were found up to 4 days after inoculation. Considering that the majority of bacteremias are due to aerobic...

  13. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  14. White Blood Cell Count

    Science.gov (United States)

    ... Pp 1003-1008. Harmening D. Clinical Hematology and Fundamentals of Hemostasis, Fifth Edition, F.A. Davis Company, Philadelphia, 2009, Pp 305-328. Henry's Clinical Diagnosis and Management by Laboratory Methods. 21st ed. McPherson R, Pincus ...

  15. Complete blood count - slideshow

    Science.gov (United States)

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  16. Automated uranium analysis by delayed-neutron counting

    International Nuclear Information System (INIS)

    Kunzendorf, H.; Loevborg, L.; Christiansen, E.M.

    1980-10-01

    Automated uranium analysis by fission-induced delayed-neutron counting is described. A short description is given of the instrumentation including transfer system, process control, irradiation and counting sites, and computer operations. Characteristic parameters of the facility (sample preparations, background, and standards) are discussed. A sensitivity of 817 +- 22 counts per 10 -6 g U is found using irradiation, delay, and counting times of 20 s, 5 s, and 10 s, respectively. Presicion is generally less than 1% for normal geological samples. Critical level and detection limits for 7.5 g samples are 8 and 16 ppb, respectively. The importance of some physical and elemental interferences are outlined. Dead-time corrections of measured count rates are necessary and a polynomical expression is used for count rates up to 10 5 . The presence of rare earth elements is regarded as the most important elemental interference. A typical application is given and other areas of application are described. (auther)

  17. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  18. Methodology for Isolation, Identification and Characterization of Microvesicles in Peripheral Blood

    Science.gov (United States)

    Jayachandran, Muthuvel; Miller, Virginia M.; Heit, John A.; Owen, Whyte G.

    2011-01-01

    Rationale Analyses of circulating cell membrane-derived microvesicles (MV) have come under scrutiny as potential diagnostic and prognostic biomarkers of disease. However, methods to isolate, label and quantify MV have been neither systematized nor validated. Objective To determine how pre-analytical, analytical and post-analytical factors affect plasma MV counts, markers for cell of origin and expression of procoagulant surface phosphatidylserine. Methods and Results Peripheral venous blood samples were collected from healthy volunteers and patients with cardiovascular disease and/or diabetes. Effects of blood sample collection, anticoagulant and sample processing to platelet free plasma (PFP), and MV isolation, staining and storage (freeze-thaw) and cytometer design were evaluated with replicate samples from these populations. The key finding is that use of citrate or EDTA anticoagulants decreases or eliminates microvesicles from plasma by inducing adhesion of the microvesicles to platelets or other formed elements. Protease inhibitor anticoagulants, including heparin, preserve MV counts. A centrifugation protocol was developed in which recovery of isolated MV was high with resolution down to the equivalent light scatter of 0.2 micron latex beads. Each procedure was systematically evaluated for its impact on the MV counts and characteristics. Conclusion This study provides a systematic methodology for MV isolation, identification and quantification, essential for development of MV as diagnostic and prognostic biomarkers of disease. PMID:22075275

  19. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  20. Antiaging Effects of an Intensive Mind and Body Therapeutic Program through Enhancement of Telomerase Activity and Adult Stem Cell Counts.

    Science.gov (United States)

    Rao, Krishna S; Chakraharti, Swarup K; Dongare, Vaishali S; Chetana, K; Ramirez, Christina M; Koka, Prasad S; Deb, Kaushik D

    2015-01-01

    Key modalities of integrative medicine known to rejuvenate the mind and body are meditation, yoga, and controlled diet. It has been shown previously that intensive or prolonged mind and body therapies (MBT) may have beneficial effects on the well-being of healthy people and in patients. Telomerase activity and levels of peripheral blood adult pluripotent stem cells (PB-APSC) are reliable markers of long-term well-being that are known to decrease with age. The objective of this study is to understand the effect of our MBT program on telomerase activity and stem cells in blood collected from the participants. Here, we have investigated the effects of an intensive three weeks MBT retreat on telomerase activity and the peripheral blood stem cells in participants before and after the MBT. A total of 108 people were enrolled in the study; 38 men and 70 women (aged 18-90) randomly assigned for the study. Telomerase activity was greater in retreat participants at the end of the MBT retreat. About 45% of people showed more than one-fold increase of telomerase activity after our MBT program. Furthermore, about 27% of people showed more pronounced fold increase (2-fold) in telomerase activity after the MBT. In addition, a substantial percentage of people (about 90%) exhibited increased stem cell counts after the MBT. The data suggest increased telomerase activity and stem cells count in peripheral blood from MBT retreat participants that may lead to increased longevity and better quality of life at latter age.

  1. Use of statistical process control in the production of blood components

    DEFF Research Database (Denmark)

    Magnussen, K; Quere, S; Winkel, P

    2008-01-01

    Introduction of statistical process control in the setting of a small blood centre was tested, both on the regular red blood cell production and specifically to test if a difference was seen in the quality of the platelets produced, when a change was made from a relatively large inexperienced...... by an experienced staff with four technologists. We applied statistical process control to examine if time series of quality control values were in statistical control. Leucocyte count in red blood cells was out of statistical control. Platelet concentration and volume of the platelets produced by the occasional...... occasional component manufacturing staff to an experienced regular manufacturing staff. Production of blood products is a semi-automated process in which the manual steps may be difficult to control. This study was performed in an ongoing effort to improve the control and optimize the quality of the blood...

  2. Counting and Surveying Homeless Youth: Recommendations from YouthCount 2.0!, a Community-Academic Partnership.

    Science.gov (United States)

    Narendorf, Sarah C; Santa Maria, Diane M; Ha, Yoonsook; Cooper, Jenna; Schieszler, Christine

    2016-12-01

    Communities across the United States are increasing efforts to find and count homeless youth. This paper presents findings and lessons learned from a community/academic partnership to count homeless youth and conduct an in depth research survey focused on the health needs of this population. Over a 4 week recruitment period, 632 youth were counted and 420 surveyed. Methodological successes included an extended counting period, broader inclusion criteria to capture those in unstable housing, use of student volunteers in health training programs, recruiting from magnet events for high risk youth, and partnering with community agencies to disseminate findings. Strategies that did not facilitate recruitment included respondent driven sampling, street canvassing beyond known hotspots, and having community agencies lead data collection. Surveying was successful in gathering data on reasons for homelessness, history in public systems of care, mental health history and needs, sexual risk behaviors, health status, and substance use. Youth were successfully surveyed across housing types including shelters or transitional housing (n = 205), those in unstable housing such as doubled up with friends or acquaintances (n = 75), and those who were literally on the streets or living in a place not meant for human habitation (n = 140). Most youth completed the self-report survey and provided detailed information about risk behaviors. Recommendations to combine research data collection with counting are presented.

  3. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    Energy Technology Data Exchange (ETDEWEB)

    Peronio, P.; Acconcia, G.; Rech, I.; Ghioni, M. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-11-15

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

  4. Diagnostic value of serum procalcitonin levels in children with meningitis: a comparison with blood leukocyte count and C-reactive protein

    International Nuclear Information System (INIS)

    Ibrahim, K.A.; Wahab, A.A.A.; Ibrahim, A.S.

    2011-01-01

    Objectives: To determine the level of serum procalcitonin, blood leukocyte count (TLC) and C-reactive protein (CRP) in children with bacterial and non bacterial meningitis and document their efficacy in differential diagnosis. Also described are procalcitonin levels variation during treatment. Methods: From March 2005 to February 2008, we evaluated 38 clinically suspected meningitis patients in the paediatric departments, Al-Jedaany Hospital, Jeddah, KSA, for Serum procalcitonin, CRP, TLC and Lumbar punctures and CSF analysis. Patients were classified into bacterial meningitis group I (18) and non bacterial meningitis group II (20). Results: Serum PCT levels were significantly higher in bacterial meningitis (BM) 9 mean 4.8 +- 3.85 ng/ml (2.9-11.6)) compared with non bacterial meningitis (NBM) (mean 0.38 +- 0.25 ng/ml(0.31-0.61)) P< 0.001). Mean of all CSF parameters, TLC (15,000 +- 2,900 cell/ml(BM) and 9,500 +-1,105 cell/ml(NBM))and CRP (20 +- 6.8 mg/l (BM) and 12.5 +-12.0 mg/l(NBM))showed a zone of overlapping between the two groups. There is a positive correlation between serum PCT, TLC and CRP in bacterial and non bacterial meningitis cases but this relation becomes highly significant with bacterial meningitis positive group. Day 3 and day 6 treatment serum PCT was less than on admission levels (P<0.001). Conclusion: PCT can be used in the early diagnosis of bacterial meningitis and may be a useful adjunct in differentiating bacterial and non bacterial meningitis than CRP or TLC and diminishing the value of lumbar puncture performed 48-72 hours after admission to assess treatment efficacy. (author)

  5. Determination of phosphorus in biological samples by thermal neutron activation followed by β--counting

    International Nuclear Information System (INIS)

    Weginwar, R.G.; Samudralwar, D.L.; Garg, A.N.

    1989-01-01

    Phosphorus was determined using the β - emitter 32 P by instrumental neutron activation analysis (INAA) in several NBS and IAEA standards, and in samples of biological origin such as human and animal blood, cancerous tissue, edible plant leaves, diets, milk samples, etc. The method involves thermal neutron irradiation (for 2-10 h in a reactor) followed by β - counting on an end-window gas flow proportional counter using aluminium filter. The results are within ±10% of the certified values in most cases. (author) 29 refs.; 3 tabs

  6. Studies on iron absorption and retention in malnourished Indian subjects, using Fe-59 and whole-body counting

    International Nuclear Information System (INIS)

    Gopalan, C.; Srikantia, S.G.

    1975-12-01

    The gastrointestinal absorption of iron under various conditions in representatives of the Indian population, and several related matters, have been investigated. Percentage absorption was determined by whole-body counting of 59Fe, or by measuring the concentration of 55Fe in the blood, at about two weeks after administration of the respective tracer. It was confirmed or established that: (1) food or supplemental iron, if available at all, tends to be absorbed from the intestines as if present there in one of two alternative pools: heme and non heme; (2) 30%-50% of iron measured chemically in Indian foods appears to be in an unavailable form, for example as a contaminant in adventitiously present dust; (3) fortification of the diet with iron may be feasible by adding FePO 4 + 2 molar NaHSO 4 to common salt under suitable conditions; (4) monkeys appear to be sufficiently similar to humans in their iron absorption characteristics that they may be the best available non-human model for preliminary experimental investigations of iron absorption; and (5) a promising preparative method for liquid scintillation counting of 55Fe present in blood is to extract it into toluene in the presence of di (2-ethyl-hexyl) phosphate (HDEHP)

  7. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  8. Elevated blood eosinophils in early infancy are predictive of atopic dermatitis in children with risk for atopy.

    Science.gov (United States)

    Rossberg, Siri; Gerhold, Kerstin; Geske, Thomas; Zimmermann, Kurt; Menke, Georg; Zaino, Mohammad; Wahn, Ulrich; Hamelmann, Eckard; Lau, Susanne

    2016-11-01

    Accessible markers to predict the development of atopic diseases are highly desirable but yet matter of debate. We investigated the role of blood eosinophils at 4 weeks and 7 months of life and their association with developing atopic dermatitis (AD) in a birth cohort of children with atopic heredity. Infant blood samples for eosinophil counts were taken from 559 infants at 4 weeks and from 467 infants at 7 month of life with at least one atopic parent. Elevation of blood eosinophils was defined as ≥ 5% of total leukocytes and the asscociation for the occurrence of AD was assessed by entering 2 × 2 tables and the odds ratios were estimated followed by hypothesis testing against the alternate working hypothesis: odds ratio 1. Survival analysis was carried out estimating the Kaplan-Meier product limit estimator from the life-time table of AD score and time to AD manifestation stratified by the eosinophil binary score. Elevated blood eosinophils observed at 4 weeks were significantly associated with the occurrence of AD in the whole cohort at the age of 7 months (p = 0.007), 1 year (p = 0.004), 2 years (p = 0.007) and 3 years (p = 0.006) of life. AD occurred app. 12 weeks earlier in infants with elevated blood eosinophils at 4 weeks of life. Blood eosinophil counts ≥5% at 7 months of life failed to show significance for AD; for eosinophils at 4.5% a significant association at 7 months (p = 0.005), and 1 year of life (p = 0.039), 2 years (p = 0.033) and 3 years (p = 0.034) was observed. Elevated blood eosinophils at age 4 weeks have a predictive value for the onset of atopic dermatitis in infancy and early childhood in children with high risk for atopy. Early eosinophil counts may therefore be helpful for counseling parents to provide infant skincare but furthermore identify individuals for interventional trials aiming at allergy prevention. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  10. Impaired blood rheology is associated with endothelial dysfunction in patients with coronary risk factors.

    Science.gov (United States)

    Yagi, Hideki; Sumino, Hiroyuki; Aoki, Tomoyuki; Tsunekawa, Katsuhiko; Araki, Osamu; Kimura, Takao; Nara, Makoto; Ogiwara, Takayuki; Murakami, Masami

    2016-01-01

    To investigate the relationship between blood rheology and endothelial function in patients with coronary risk factors, brachial arterial flow-mediated vasodilatation (FMD), an index of endothelial function and blood passage time (BPT), an index of blood rheology, and fasting blood cell count, glucose metabolism, and plasma fibrinogen, lipid, C-reactive protein, and whole blood viscosity levels were measured in 95 patients with coronary risk factors and 37 healthy controls. Brachial arterial FMD after reactive hyperemia was assessed by ultrasonography. BPT was assessed using the microchannel method. In healthy controls, BPT significantly correlated with FMD (r = - 0.325, p index (BMI; r = 0.530, p measurement of blood rheology using the microchannel method may be useful in evaluating brachial arterial endothelial function as a marker of atherosclerosis in these patients.

  11. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  12. Reduction of bioactive substances in stored donor blood: prestorage versus bedside leucofiltration

    DEFF Research Database (Denmark)

    Hammer, J H; Mynster, T; Reimert, C M

    1999-01-01

    Leucocyte filtration has been suggested to improve transfusion products. We studied the effect of prestorage versus bedside leucofiltration on reduction of bioactive substances and leucocyte content in donor blood. Forty-five units of whole blood from healthy blood donors were studied....... Of these units, 9 were stored under standard conditions for 35 d, 9 were leucofiltered after donation and then stored for 35 d, and 3x9 units were stored for 7, 21 and 35 d, respectively, before leucofiltration. Samples were collected from blood units immediately after donation, and before and after...... leucofiltration, and analysed by ELISA and RIA methods for extracellular content of myeloperoxidase (MPO), eosinophil cationic protein (ECP), histamine (HIS) and plasminogen activator inhibitor-1 (PAI-1). Leucocyte content was counted in all samples. In non-filtered blood extracellular MPO, ECP, HIS and PAI-1...

  13. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  14. Response of peripheral blood to 131I treatment in Swiss albino mice

    International Nuclear Information System (INIS)

    Jagetia, G.C.; Gupta, S.M.; Kumar, S.; Devi, P.U.

    1982-01-01

    Adult Swiss albino mice were treated with 333 kBq/g body weight (approximately 10.22 Gy/day) intraperitoneally and sacrificed at different post-treatment intervals. It was observed that erythrocyte counts, hemoglobin and hematocrit values decreased gradually, while the depletion in leukocyte count was abrupt at early intervals after treatment. The early decline in the leukocytes followed by more gradual may be due to the direct cell killing by the isotope. The indirect effect on the hematopoietic tissues may be responsible for the continued low levels of the different blood constituents during the later intervals. (author)

  15. Evaluation of Complete Blood Count Indices (NLR, PLR, MPV/PLT, and PLCRi) in Healthy Dogs, Dogs With Periodontitis, and Dogs With Oropharyngeal Tumors as Potential Biomarkers of Systemic Inflammatory Response.

    Science.gov (United States)

    Rejec, Ana; Butinar, Janos; Gawor, Jerzy; Petelin, Milan

    2017-12-01

    The aim of the study was to retrospectively assess complete blood count (CBC) indices of dogs with periodontitis (PD; n = 73) and dogs with oropharyngeal tumors (OT; n = 92) in comparison to CBC indices of healthy dogs (HD; n = 71). Neutrophil to lymphocyte ratio (NLR), platelet to lymphocyte ratio, mean platelet volume to platelet ratio, and platelet large cell ratio index (PLCRi) were evaluated as biomarkers of systemic inflammatory response provoked by PD and OT. Results of multivariable polytomous logistic regression analysis indicated no significant associations between CBC indices and PD. Both NLR and PLCRi were significantly higher in dogs with OT when compared to HD and dogs with PD and could, therefore, indicate a tumor-associated systemic inflammatory response. Additional studies of CBC indices, along with other biomarkers of systemic inflammatory response, are recommended to validate them as reliable indicators of clinical disease activity.

  16. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  17. Weight-length relationship, condition factor and blood parameters of farmed Cichla temensis Humboldt, 1821 (Cichlidae in central Amazon

    Directory of Open Access Journals (Sweden)

    Marcos Tavares-Dias

    Full Text Available Farming of native carnivore fish species has drawn attention due to their promising use in aquaculture. Among these species, tucunaré of the genus Cichla stand out, them being of high economical interest for sport fishing and Amazon's industry of ornamental fish. The present study describes the weight-length relationship (WLR, relative condition factor (Kn, red blood cell parameters, thrombocytes and leukocytes count of Cichla temensis Humboldt, 1821, farmed in central Amazon. Fish that underwent food training during fingerling culture received extruded ration containing 45% of crude protein during fattening, and had Kn with values from 0.925-1.199, which indicated good health condition during the culture. The equation obtained from the WLR was W = 0.0073Lt3.1435, indicating an isometric growth, which is the desirable for fish of fish farm. Red blood cell counts, total thrombocyte and leukocyte counts, hematocrit, hemoglobin concentration, mean corpuscular volume (MCV, concentration of mean corpuscular hemoglobin (MCHC, lymphocytes, monocytes and neutrophils had intra-specific variation. A significant (p<0.001 positive correlation of the red blood cells number with the hemoglobin concentration and hematocrit was found. These are the first sets of blood parameters for C. temensis and could be used as reference for comparison in further studies to evaluate the health status of this fish in different environments, because assessment of these parameters may be used as quick tool for diagnosing diseases, stress and malnutrition.

  18. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R

    2011-01-01

    in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP......-test. The WB responses decreased at platelet concentration of ≤100 × 10(9)/L (all P PRP samples at platelet concentrations 200 to 100 × 10(9)/L (P

  19. Blood conservation in cardiac surgery. Preliminary results with an institutional commitment.

    Science.gov (United States)

    Tyson, G S; Sladen, R N; Spainhour, V; Savitt, M A; Ferguson, T B; Wolfe, W G

    1989-06-01

    To evaluate the effect of blood conservation in cardiac surgery, use of blood products was analyzed in patients undergoing CABG before and after implementation of blood conservation techniques. Age, sex, coronary anatomy, ejection fraction, cardiopulmonary bypass time, and the preoperative hematocrit, platelet count, and clotting studies were similar in both groups. Methods of blood conservation included autologous transfusion of blood withdrawn before bypass, autotransfusion of shed mediastinal blood, strict protocols for transfusion, and acceptance of normovolemic anemia. With blood conservation, 25.5% of patients received no transfusions and 54.9% received blood only. Significant reductions (p less than 0.001) were achieved in the transfusion of blood from 6.8 +/- 2.4 to 2.3 +/- 2.6 units per patient and of plasma from 2.5 +/- 2.2 to 0.6 +/- 2.0 units per patient. Reductions in the use of platelets and cryoprecipitate were substantial, although not significant. Total donor exposure was reduced significantly from 13.1 +/- 7.3 to 4.3 +/- 6.7 donors per patient. The postoperative hematocrit was significantly lower and remained so at discharge. However, 30 days later there was no difference. This reduction in transfusion requirements decreased costs and donor exposure.

  20. Validity of total leucocytes count and neutrophil count (differential leucocytes) in diagnosing suspected acute appendicitis

    International Nuclear Information System (INIS)

    Anwar, M.W.; Abid, I.

    2012-01-01

    Objective: To compare the diagnostic accuracy of Total Leucocytes Count (TLC) with Neutrophil count; Differential Leucocytes Count (DLC) in diagnosing cases of suspected acute appendicitis. Study design: Validation study. Place and duration of the study: Department of Surgery, Combined Military Hospital (CMH) Rawalpindi, from April 2008 to October 2008. Method: A total of 100 patients of Pain right iliac fossae who underwent appendicectomy were included. Detailed history of all the patients was taken for pain in right lower abdomen, its severity, its nature, relieving or provoking factors. Clinical examination was done in detail. Total and Differential Leucocytes Count was done. Every patient's appendix was examined grossly after appendicectomy for evidence of appendicitis. Diagnostic measures of TLC and DLC were calculated by standard formulas. Results: Sensitivity and specificity of TLC is 86.9% and 81.25% respectively and that of DLC is 82% and 68.75% respectively. Accuracy was 86% for TLC and 80% for DLC. Conclusion: TLC is more sensitive, specific and accurate test as compared to DLC and it should be used as diagnostic aid for suspected acute appendicitis cases. (author)