BackgroundCharacterizing and comparing the determinant of cotinine concentrations in different populations should facilitate a better understanding of smoking patterns and addiction....Full Text Available
Chlorine is widely used in drinking water disinfection due to be a powerful and not expense disinfection. Although the benefits of disinfection, the formation of stable disinfection by-products of the health concern, is the result of the interaction of aqueous chlorine with natural organic matter presents in water. Disinfection by-products generated in major concentration are trihalomethane and haloacetic acids. Disinfection by-products generated in minor concentration are haloacetonitriles, haloketones,chloral hydrate and chloropicrin and some new groups such as cyanogen halides and trihaloacetaldydes. In this work two analytical methods.: headspace/gas chromatography/electron capture detector and liquid-liquid microextraction/gas chromatography/electron capture detector are studied and compared to determine the minor by-products and to establish finally, a systematic control of them in the different stages of the Water Treatment Plant of San Joan Despi ...
THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.
This contribution analyzes elastic-backscatter lidar data and temperature and humidity profiles from radiosondes acquired in Barcelona in July 1992. Elastic-backscatter lidar data reveal the distribution of aerosols within the volume of atmosphere scanned. By comparing this information with temperature and humidity profiles of the atmosphere at a similar time, we are able to asses de relationship among aerosol distribution and atmospheric stability or water content, respectively. Comparisons have shown how lidar`s revealed layers of aerosols correspond to atmospheric layers with different stability condition and water content.
The purpose of this research was to develop a methodology for sizing integrated renewable energy systems, useful for rural areas, using simulation and optimization tools developed in MATLAB 6.0. The sizing model produces a system with minimum cost and high reliability level, based on the concept of loss of power supply probability (LPSP) for consecutive hours. An optimization model is presented and three different sizing scenarios are calculated and compared, showing flexibility in the elaboration of different project conceptions. The obtained results show a complete sizing of the energy conversion devices and a long-term cost evaluation. (author)
AbstractTrends in Nanotechnology (TNT2009) This special issue of Physica Status Solidi presents representative contributions describing the main topics covered at the 10th Trends in Nanotechnology (TNT2009) International Conference, held in Barcelona (Spain), September 07 11, 2009. During the last years many international or national conferences have emerged in response to the growing awareness of the importance of nanotechnology as key issue for the future scientific and technological development. Among these, the conference series Trends in Nanotechnology has become one of the most important meeting points in the nano technology field: it provides fresh organisation ideas, brings together well known speakers, and promotes a suitable environment for discussions, exchanging ideas, enhancin...
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Municipal waste charges in Spain are very widespread, although their application varies significantly among different municipalities. Most commonly, waste charges are implemented as a flat rate, but some of them depend on indicators such as household water consumption, the land area of the property or the value of the real estate. Only one residential pay-as-you-throw scheme has been applied so far. It was a pay-per-bag scheme implemented in Torrelles de Llobregat, Barcelona. A number of other systems focussing only on commercial waste have been implemented in Spain. Several factors suggest that new pay-as-you-throw schemes will be adopted in the near future. In 2000 no municipalities had door-to-door collection schemes; since then over 70 municipalities have implemented them. In addition ...
Since 1988, the Expertise group of Molecular and Cellular Biology (MCB) is an important partner in the development of the Micro-Ecological Life Support System Alternative (MELiSSA). The MELiSSA was designed to allow a small crew to survive on an Antarctic, lunar or Mars outpost, and is a joint research project currently fostered by the European Space Agency, ESA. The MELiSSA functions through a series of five interconnected compartments, of which four are microbial bioreactors and was engineered to degrade organic waste, regenerate the outpost's atmosphere and water, and provide the crew with an additional vegetarian diet. The bioreactor of the third compartment provides the edible cyanobacteria and plants of the fourth compartment with nitrate instead of ammonium as a source of nitrogen. The two bacteria responsible for the biological transformation of ammonium to nitrate (nitrification) are Nitrosomonas europaea and Nitrobacter winogradskyi. Since all MELiSSA-reactors are to be ...
This work presents comparative results of a numerical investigation of four possible models for the prediction of thermal performance of fixed bed storage units and their thermal design. These models includes Schumann's model, the radial dispersion model, a model that include both axial heat conduction in the fluid phase and admits thermal gradient in the solids particles and finally a two dimensional single phase model. For each of these models a computer code was written and tested to evaluate the computing time of same data and analyze any other computational problems. The tests of thermal performance included particle size, porosity, particle material, flow rate, inlet temperature and heat losses form tank walls and extremities. Dynamics behaviour of the storage units due to transient variation in either flow rate or inlet temperature was also investigated. The results presented include temperature gradients, pressure drop and heat storage. The results obtained are very ...
Objetivo La generacion local de citocinas es un factor patogenico en el dano por isquemia-reperfusion en la disfuncion precoz del injerto. Este estudio analiza la expresion en tejido pulmonar de ARN mensajero de interleucina-8 (ARNm de IL-8) y su relacion con los cambios intersticiales pulmonares en un modelo experimental de isquemia-reperfusion pulmonar normotermica. MATERIAL Y METODOS Se estudiaron 16 conejos de la raza Nueva Zelanda en 3 grupos de estudio: a) basal; b) isquemia (lobulo inferior derecho tras isquemia de 1, 2 o 3 h), y c) reperfusion (lobulos superior y medio derechos tras 1 h de isquemia y 1, 2 o 3 h de reperfusion). Se deter- mino la expresion del ARNm de IL-8 mediante transcripcion inversa y reaccion en cadena de la polimerasa y estudio la infiltracion intersticial por...
The provincial ministry of health has taken over a dialysis center in La Plata, Argentina, following the discovery that at least 20 of the clinic's 34 regular patients have been infected with the human immunodeficiency virus (HIV). Catheters of the clinic's dialysis machines were found to be contaminated with HIV. The 5 physicians associated with the Centro Modelo de Dialisis have been discharged for negligence. 20 of the regular patients also contracted hepatitis C. Argentinian law stipulates that filters for the same patient must be changed after 4 times and prohibits the use of the same vessel to administer medication to more than 1 patient. Testimony from nurses at the La Plata clinic revealed that filters were reused for several patients and basic sanitary procedures were not followed. In 1990, 33 kidney disease patients at a dialysis center in Cordoba became infected with HIV and it was discovered that filters had been used up to 8 times for different ...
The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has drawn that several laboratories have difficulties in the evaluation of combined uncertainty, mainly in analysis involving ...
From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors ...
Since 1994 the radon studies group at the Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya in Barcelona, Spain, has carried out a campaign of continuous measurements of the equilibrium factor (F) and the unattached fraction (f_p) of radon decay products at four sites which are representative of different environmental characteristics on the Mediterranean littoral of Catalonia, Spain. It has been established that these parameters vary widely, F(0.03--0.87) and f_p (0--0.72), from one site to another and with time, according to the characteristics on the site and climate. In spite of this variation, the F and f_p parameters are log-normally or normally distributed. The measurements of F and f_p show that f_p is negatively correlated to F by a log-power equation, Ln(1/f_p)=1.90[Ln(1/F)]"-"0"."6"8, which can be used in all the F range, instead of the commonly used power equation f_p=aF"b suggested by Stranden and Strand and other ...
It turns out of interest to Comision Federal de Electricidad and Petroleos Mexicanos to reduce costs of fuel oil, reducing the viscosity of the residues petroleum of high vacuum distillation emulsifying these with water. The parameters that define the characteristics of the emulsions are mainly the relation of their components, viscosity, size and drop distribution and its stability. The experimental work began producing emulsions in form of lots, using samples of approximately 500 milliliters of vacuum residue. In this first stage, at different concentrations, were examined eight different surfactants, as well as combinations among them, also seven different stabilizers were used. With these tests it has been managed to identify the concentrations, as well as the most adequate relations of surfactants and stabilizers for the production of emulsions of vacuum residues in water. The size and drop distribution has been determined by means of an optical LEICA microscope, model DMLS, that ...
Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was concluded the most active fault system was El Volcan. From ...