WorldWideScience
1

Scalar field cosmology in three-dimensions  

Energy Technology Data Exchange (ETDEWEB)

We study an analytical solution to the Einstein's equations in 2 + 1-dimensions. The space-time is dynamical and has a line symmetry. The matter content is a minimally coupled, massless, scalar field. Depending on the value of certain parameters, this solution represents three distinct space-times. The first one is at space-time. Then, we have a big bang model with a negative curvature scalar and a real scalar field. The last case is a big bang model with event horizons where the curvature scalar vanishes and the scalar field changes from real to purely imaginary. (author)

2001-09-01

2

Cosmological models without singularities  

Energy Technology Data Exchange (ETDEWEB)

A previously studied theory of gravitation in flat space-time is applied to homogeneous and isotropic cosmological models. There exist two different classes of models without singularities: (i) ever-expanding models, (ii) oscillating models. The first class contains models with hot big bang. For these models there exist at the beginning of the universe-in contrast to Einstein's theory-very high but finite densities of matter and radiation with a big bang of very short duration. After short time these models pass into the homogeneous and isotropic models of Einstein's theory with spatial curvature equal to zero and cosmological constant ALPHA >= O.

1981-11-01

3

The structure of the big bang from higher-dimensional embeddings  

Energy Technology Data Exchange (ETDEWEB)

We give relations for the embedding of spatially-flat Friedmann-Robertson-Walker cosmological models of Einstein's theory in flat manifolds of the type used in Kaluza-Klein theory. We present embedding diagrams that depict different 4D universes as hypersurfaces in a higher-dimensional flat manifold. The morphology of the hypersurfaces is found to depend on the equation of state of the matter. The hypersurfaces possess a line-like curvature singularity infinitesimally close to the t 0{sup +} 3-surface, where t is the time expired since the big bang. The family of timelike comoving geodesics on any given hypersurface is found to have a caustic on the singular line, which we conclude is the 5D position of the point-like big bang.

2002-03-21

4

CERN's 'Big Bang' experiment given green light  

CERN Document Server

CERN's 'Big Bang' experiment given green light

2008-01-01

5

Big Bang experiment given green light  

CERN Document Server

Big Bang experiment given green light

2008-01-01

6

Gravitational waves from the big bang  

Energy Technology Data Exchange (ETDEWEB)

The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.

1980-12-20

7

Early universe in a generalized theory of gravitation  

Energy Technology Data Exchange (ETDEWEB)

The standard Friedmann-Robertson-Walker (FRW) big bang model of the universe requires special initial conditions: the early universe is highly homogeneous and isotropic even though there exist causally disconnected regions (horizon problem). A plane symmetric (anisotropic) solution of field equations in a generalized theory of gravitation predicts the beginning of the universe as a vacuum instability at a specific fundamental time (which can be associated with the Planck time (tsub(p))), after which matter is created as the universe begins to expand. At a time t=tsub(c) there is a singular expansion, the anisotropy vanishes, and the physical horizon becomes infinite. Thereafter the solution of the field equations goes over into the FRW model. Thus the special initial conditions of the FRW model at the big bang singularity t=tsub(c) are predicted by the theory.

1982-05-01

8

Tachyons and cosmology  

International Nuclear Information System (INIS)

The propagating of tachyons in an expanding universe is discussed. It is shown that a primordial tachyon in the big-bang universe cannot survive unless it had very large energy initially. In an indefinitely expanding universe the tachyon trajectory turns back in time. This time barrier is found to exist even in the quantum mechanical discussion of tachyons. This property is used to set limits on the mass of a tachyon. The possible astronomical checks on the hypothesis that neutrinos or photons may be tachyonic are also discussed. (author).

9

Tachyons and cosmology  

International Nuclear Information System (INIS)

The propagation of tachyons in an expanding universe is discussed. It is shown that a primordial tachyon in the big bang universe cannot survive unless it had very large energy initially. In an indefinitely expanding universe the tachyon trajectory turns back in time. This time barrier is found to exist even in the quantum mechanical discussion of tachyons. This property is used to set limits on the mass of a tachyon. The possible astronomical checks on the hypothesis that neutrinos or photons may be tachyonic are also discussed.

10

Ekpyrotic and cyclic cosmology  

Energy Technology Data Exchange (ETDEWEB)

Ekpyrotic and cyclic cosmologies provide theories of the very early and of the very late universe. In these models, the big bang is described as a collision of branes - and thus the big bang is not the beginning of time. Before the big bang, there is an ekpyrotic phase with equation of state w=P/({rho}) >>1 (where P is the average pressure and {rho} the average energy density) during which the universe slowly contracts. This phase resolves the standard cosmological puzzles and generates a nearly scale-invariant spectrum of cosmological perturbations containing a significant non-Gaussian component. At the same time it produces small-amplitude gravitational waves with a blue spectrum. The dark energy dominating the present-day cosmological evolution is reinterpreted as a small attractive force between our brane and a parallel one. This force eventually induces a new ...

2008-09-15

11

Effective Dynamics, Big Bounces and Scaling Symmetry in Bianchi Type I Loop Quantum Cosmology  

CERN Document Server

The detailed formulation for loop quantum cosmology (LQC) in the Bianchi I model with a scalar massless field has been constructed. In this paper, its effective dynamics is studied in two improved strategies for implementing the LQC discreteness corrections. Both schemes show that the big bang is replaced by the big bounces, which take place up to three times, once in each diagonal direction, when the area or volume scale factor approaches the critical values in the Planck regime measured by the reference of the scalar field momentum. These two strategies give different evolutions: In one scheme, the effective dynamics is independent of the choice of the finite sized cell prescribed to make Hamiltonian finite; in the other, the effective dynamics reacts to the macroscopic scales introduced by the boundary conditions. Both schemes reveal interesting symmetries of scaling, which are reminiscent of the relational ...

2007-01-01

12

D-branes in a big bang/big crunch universe: Misner space  

Energy Technology Data Exchange (ETDEWEB)

We study D-branes in a two-dimensional lorentzian orbifold R{sup 1,1}/{gamma} with a discrete boost {gamma}. This space is known as Misner or Milne space, and includes big crunch/big bang singularity. In this space, there are D0-branes in spiral orbits and D1-branes with or without flux on them. In particular, we observe imaginary parts of partition functions, and interpret them as the rates of open string pair creation for D0-branes and emission of winding closed strings for D1-branes. These phenomena occur due to the time-dependence of the background. Open string 2{yields}2 scattering amplitude on a D1-brane is also computed and found to be less singular than closed string case.

2005-09-01

13

Cosmology of Nordstroem's first theory of gravitation  

Energy Technology Data Exchange (ETDEWEB)

Nordstroem's first theory of gravitation, which is a Lorentz covariant scalar theory, is discussed, and the cosmological solution to the field equation is derived. It is shown that there are two physically equivalent representations of the theory that differ in the system of units with which measurements are made. The cosmological solution is found to be an infinite, Euclidean universe with a big bang and a big crunch.

1982-03-01

14

A journey inside infinity; Voyage au coeur de l'infini  

Energy Technology Data Exchange (ETDEWEB)

The authors draw the story of the concept of infinity in sciences from the ancient Greek civilization to modern times, from the Greek idea of atom to quantum physics and cosmology. It is shown how what was considered as limits in ancient times, have been progressively seen as unknown worlds, and are now being investigated with the use of big machines like particle accelerators. This book is composed of 3 main chapters: 1) the quest for the infinitely big, 2) the quest for the infinitely small, and 3) the big-bang theory that appears as the meeting point of the 2 infinites. (A.C.)

2010-07-01

15

Big bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

A brief review of standard big bang nucleosynthesis theory and the related observations of the light element isotopes is presented. Implications of BBN on chemical evolution and constraints on particle properties will also be discussed.

2000-01-01

16

Before the Big Bang  

ScienceCinema

...you know global warming and all that but that's a very small ...

17

Non-Abelian T-duality in pre-big-bang cosmology  

Energy Technology Data Exchange (ETDEWEB)

We study the impact of non-Abelian T-duality transformations on a string based cosmological model. The implementation of the pre-big-bang scenario is investigated. We found a region of the dual phase where such a picture is possible.

2003-02-17

18

Big bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The concordance of standard big bang nucleosynthesis theory and the related observations of the light element isotopes (including some new higher {sup 4}He abundances) will be reviewed. Implications of BBN on chemical evolution, dark matter and constraints on particle properties will be discussed.

1999-01-01

19

Effective equations of motion for constrained quantum systems: A study of the Bianchi I loop quantum cosmology  

CERN Document Server

A new mathematical framework is formulated to derive the effective equations of motion for the constrained quantum system which possesses an internal clock. In the realm close to classical behavior, the quantum evolution is approximated by a finite system of coupled but ordinary differential equations adhered to the weakly imposed Hamiltonian constraint. For the simplified version of loop quantum cosmology in the Bianchi I model with a free massless scalar filed, the resulting effective equations of motion affirm the bouncing scenario predicted by the previous studies: The big bang singularity is resolved and replaced by the big bounces, which take place up to three times, once in each diagonal direction, whenever the directional density approaches the critical value in the regime of Planckian density. It is also revealed that back-reaction arises from the quantum corrections and modifies the precise value of the directional density at the ...

2008-01-01

20

Prospects for the direct detection of the cosmic neutrino background  

Energy Technology Data Exchange (ETDEWEB)

The existence of a cosmic neutrino background - the analogue of the cosmic microwave background - is a fundamental prediction of standard big bang cosmology. Up to now, the observational evidence for its existence is rather indirect and rests entirely on cosmological observations of, e.g., the light elemental abundances, the anisotropies in the cosmic microwave background, and the large scale distribution of matter. Here, we review more direct, weak interaction based detection techniques for the cosmic neutrino background in the present epoch and in our local neighbourhood. We show that, with current technology, all proposals are still off by some orders of magnitude in sensitivity to lead to a guaranteed detection of the relic neutrinos. The most promising laboratory search, based on neutrino capture on beta decaying nuclei, may be done in future experiments designed to measure the neutrino mass through decay kinematics. (orig.)

2009-01-15

21

Phenomenological dynamics of loop quantum cosmology in Kantowski-Sachs spacetime  

CERN Document Server

The full theory and the semiclassical description of loop quantum cosmology (LQC) have been studied in the Friedmann-Robertson-Walker and Bianchi I models. As an extension to include both anisotropy and intrinsic curvature, this paper investigates the cosmological model of Kantowski-Sachs spacetime with a free massless scalar field at the level of phenomenological dynamics with the LQC discreteness corrections. The LQC corrections are implemented in two different improved quantization schemes. In both schemes, the big bang and big crunch singularities of the classical solution are resolved and replaced by the big bounces when the area or volume scale factor approaches the critical values in the Planck regime measured by the reference of the scalar field momentum. Symmetries of scaling are also noted and suggest that the fundamental spatial scale (area gap) may give rise to a temporal scale. The bouncing scenarios are in an analogous fashion of ...

2008-01-01

22

Kasner asymptotics of mixmaster Horava-Witten and pre-big-bang cosmologies  

Energy Technology Data Exchange (ETDEWEB)

We discuss various superstring effective actions and, in particular, their common sector which leads to the so-called pre-big-bang cosmology (cosmology in a weak coupling limit of heterotic superstring theory). Using the conformal relationship between these two theories we present Kasner asymptotic solutions of Bianchi type IX geometries within these theories and make predictions about possible emergence of chaos. Finally, we present a possible method of generating Horava-Witten cosmological solutions out of the well-known general relativistic or pre-big-bang solutions.

2001-09-01

23

Kasner asymptotics of mixmaster Horava-Witten and pre-big-bang cosmologies  

International Nuclear Information System (INIS)

We discuss various superstring effective actions and, in particular, their common sector which leads to the so-called pre-big-bang cosmology (cosmology in a weak coupling limit of heterotic superstring theory. Using the conformal relationship between these two theories we present Kasner asymptotic solutions of Bianchi type IX geometries within these theories and make predictions about possible emergence of chaos. Finally, we present a possible method of generating Horava-Witten cosmological solutions out of the well-known general relativistic or pre-big-bang solutions.

2001-09-01

24

How quantum is the big bang?  

CERN Document Server

When quantum gravity is used to discuss the big bang singularity, the most important, though rarely addressed, question is what role genuine quantum degrees of freedom play. Here, complete effective equations are derived for isotropic models with an interacting scalar to all orders in the expansions involved. The resulting coupling terms show that quantum fluctuations do not affect the bounce much. Quantum correlations, however, do have an important role and could even eliminate the bounce. How quantum gravity regularizes the big bang depends crucially on properties of the quantum state.

2008-01-01

25

Dirac Fields in Loop Quantum Gravity and Big Bang Nucleosynthesis  

CERN Document Server

Big Bang nucleosynthesis requires a fine balance between equations of state for photons and relativistic fermions. Several corrections to equation of state parameters arise from classical and quantum physics, which are derived here from a canonical perspective. In particular, loop quantum gravity allows one to compute quantum gravity corrections for Maxwell and Dirac fields. Although the classical actions are very different, quantum corrections to the equation of state are remarkably similar. To lowest order, these corrections take the form of an overall expansion-dependent multiplicative factor in the total density. We use these results, along with the predictions of Big Bang nucleosynthesis, to place bounds on these corrections.

2007-01-01

26

Experimental Immunization with Live Strains of Bacterium ...  

Science.gov (United States)

... The serum shows an agltnation titer of between 80 and 320 aainst Bsaterium tulganse and 0-40 a ainst Brucela Bang (*ompathetic agglutination ...

1968-07-01

27

Isotopic composition of elements in extra-terrestrial materials 1  

Energy Technology Data Exchange (ETDEWEB)

The present review focuses on the isotropic composition in extra-terrestrial materials. There are many different factors in the variation in isotopic abundance between terrestrial and extra-terrestrial materials. Major factors in unusual isotopic composition are roughly grouped into three categories: factors associated with fractionation of isotopes, nuclear reaction or radioactive disintegration. Fractionation takes place due to differences in mass among various isotopes. There are physical and chemical factors. Physical ones include vaporization and condensation which meteorites may experience during their formation while the chemical ones include chemical reactions and chemical equilibration. There phenomena are mentioned as factors in the variation in isotopic ratio which is associated with nuclear reactions. An important nuclear reaction is the formation of elements that has been occurring continuously in stars since the big bang. The other two phenomena are ...

1989-02-01

28

Strange matter and Big Bang helium synthesis  

Energy Technology Data Exchange (ETDEWEB)

Stable strange quark matter produced in the QCD phase transition in the early universe will trap neutrons and repel protons, thus reducing primordial helium production, Ysub(p). For reasonable values of Ysub(p), the radius of strange droplets must exceed 10/sup -6/ cm if strange matter shall solve the dark-matter problem without spoiling Big Bang helium synthesis. (orig.).

1985-08-15

29

Strange matter and Big Bang helium synthesis  

Energy Technology Data Exchange (ETDEWEB)

Stable strange quark matter produced in the QCD phase transition in the early universe will trap neutrons and repel protons, thus reducing primordial helium production, Ysub(p). For reasonable values of Ysub(p), the radius of strange droplets must exceed 10/sup 6/ cm if strange matter shall solve the dark-matter problem without spoiling Big Bang helium synthesis. (orig.).

1985-08-15

30

Periodic optimal control with application to pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

This paper suggests how nonlinear periodic optimal control of a pumped storage plant can be realized. The control problem consists in maximization of the plant benefits over an operational period. An optimal control law is proposed, yielding a bang-off-bang mode of operation. An algorithm for numerical solution of the problem was developed, and its effectiveness was demonstrated by simulation experiments.

1987-04-01

31

Gauge-invariant gravitational wave modes in pre-big bang cosmology  

Energy Technology Data Exchange (ETDEWEB)

The t<0 branch of pre-big bang cosmological scenarios is subject to a gravitational wave instability. The unstable behaviour of tensor perturbations is derived in a very simple way in Hwang's covariant and gauge-invariant formalism developed for extended theories of gravity. A simple interpretation of this instability as the effect of an ''antifriction'' is given, and it is argued that a universe must eventually enter the expanding phase. (orig.)

2010-11-15

32

Cosmological implications of helium and deuterium abundances on Jupiter and Saturn  

Energy Technology Data Exchange (ETDEWEB)

The determination of relative abundances of helium and deuterium in Jupiter and Saturn provides estimates of the primordial abundances of these elements. The values so inferred can be compared with theoretical predictions of the standard model of the big-bang theory as a test of the model and suggest either that deuterium is more efficiently consumed in subsequent nucleosynthesis than hitherto assumed, or that the standard big-bang model should be revised in order for there to have been less production of primordial helium.

1983-03-17

33

Big bang nucleosynthesis and finite temperature field theory  

Energy Technology Data Exchange (ETDEWEB)

We consider electromagnetic corrections at finite temperature and their effect on the nucleosynthesis in the standard Big Bang scenario. This requires discussing the finite, temperature dependent correction to the neutron-proton mass difference as well as making use of a previous result on the temperature correction to the mass of the electron. We find that these corrections do not affect the conventional results of e.g. the helium abundance to any appreciable extent.

1982-11-11

34

Adiabatic CMB perturbations in pre-Big-Bang string cosmology  

Energy Technology Data Exchange (ETDEWEB)

We consider the pre-Big-Bang scenario with a massive axion field which starts to dominate energy density when oscillating in an instanton-induced potential and subsequently reheats the universe as it decays into photons, thus creating adiabatic CMB perturbations. We find that the fluctuations in the axion field can give rise to a nearly flat spectrum of adiabatic perturbations with a spectral tilt {delta}n in the range -0.1< or approx. {delta}n < or approx. 1.

2002-04-01

35

Superhorizon curvaton amplitude in inflation and pre-big bang cosmology  

Energy Technology Data Exchange (ETDEWEB)

We follow the evolution of the curvaton on superhorizon scales and check that the spectral tilt of the curvaton perturbations is unchanged as the curvaton becomes non-relativistic. Both inflation and pre-big bang cosmology can be treated since the curvaton mechanism within the two scenarios works the same way. We also discuss the amplitude of the density perturbations, which leads to some interesting constrains on the pre-big bang scenario. It is shown that within a SL(3,R) non-linear sigma model one of the three axions has the right coupling to the dilaton and moduli to yield a flat spectrum with a high string scale, if a quadratic non-perturbative potential is generated and an intermediate string phase lasts long enough.

2003-04-21

36

Satisfying story of how it all began  

Energy Technology Data Exchange (ETDEWEB)

{sup N}ow this 'Big Bang' idea seemed to me to be unsatisfactory...for it is an irrational process that cannot be described in scientific terms.' With this rather derisory remark (or at least so intended) in a 1950 radio broadcast, Fred Hoyle named the theory that rivalled his steady-state theory. The Big Bang has subsequently become the dominant paradigm in attempts to understand our universe. It is also one of the dominant ways in which popular-science writing seeks to persuade people to part with their cash. Simon Singh has rapidly made a name for himself as one of the leading popularizers of science, with his previous books Fermat's Last Theorem and The Code Book bringing accessible science to a wide audience . Big Bang brings him to a much busier marketplace, where he must compete both with other science writers and with working scientists. (U.K.)

2004-12-01

37

Introduction to Big Bang nucleosynthesis: open and closed models, anisotropies  

Energy Technology Data Exchange (ETDEWEB)

A variety of observations suggest that the Universe had a hot dense origin and that the pregalactic composition of the Universe was determined by nuclear reactions that occurred in the first few minutes. There is no unique hot Big Bang theory, but the simplest version produces a primeval chemical composition that is in good qualitative agreement with the abundances deduced from observation. Whether or not any Big Bang theory will provide quantitative agreement with observations depends on a variety of factors in elementary particle physics (number and masses of stable or long-lived particles, half-life of neutron, structure of grand unified theories) and from observational astronomy (present mean baryon density of the Universe, the Hubble constant and deceleration parameter). The influence of these factors on the abundances is discussed, as is the effect of departures from homogeneity and isotropy in the early Universe.

1982-10-15

38

Indian Academy of Sciences - Journal of Astrophysics and Astronomy  

Indian Academy of Sciences (India)

indian academy of sciences - journal of astrophysics and astronomy on astronomy (eds. v. k. kapahi, n. k. dadhich, g. swarup and special issue in honour of s. chandrasekhar big bang and alternative cosmologies; ...

39

hh911.cpr  

Science.gov (United States)

"ID# ","Measurement ID Number " "DATE ","Date " "JDATE ","Julian Date " "TIME ", "Local Time " "GMT ","Greenwich Mean Time " "BAND ","Dielectric Probe Band ...

40

Large-scale baryon isocurvature inhomogeneities  

Energy Technology Data Exchange (ETDEWEB)

Big bang nucleosynthesis constraints on baryon isocurvature perturbations are determined. A simple model ignoring the effects of the scale of the perturbations is first reviewed. This model is then extended to address the claim that large amplitude perturbations will collapse, preventing their baryons from contributing to the observed baryon density. It is found that baryon isocurvature perturbations are constrained to provide only a slight increase in the density of baryons in the universe over the standard homogeneous model. In particular, it is found that models which rely on power laws and the random phase approximation for the power spectrum are incompatible with big bang nucleosynthesis unless an ad hoc, small-scale cutoff is included. {copyright} {ital 1995 The American Astronomical Society.}

1995-09-01

41

Measurement of time of travel in streams by dye tracing  

Energy Technology Data Exchange (ETDEWEB)

The US Geological survey is active in measuring time of travel in streams using dye tracers. This manual describes methods of measuring time of travel of water and waterborne solutes by dye tracing. The fluorescent dyes, measuring equipment used, and field and laboratory procedures are also described. Methods of analysis and presentation to illustrate time of travel of streams are provided.

1989-01-01

42

The tunneling universe in scalar-tensor theory with matter  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the wavefunction of the universe with a tunneling boundary condition is considered in the context of the Brans-Dicke-type scalar-tensor theory with matter. The matter may be interpreted as a D-particle (or D0-brane) in string theory when the Brans-Dicke parameter {omega} is -1. We study two simple examples. The first example, the {gamma}=0 (matter) case, has a scale factor duality even if the low energy string action is coupled to matter. The universe undergoes quantum transition from super-inflationary (pre-big-bang) to deflationary (post-big-bang) phase. We calculate the transition rate by solving the Wheeler-DeWitt equation and find that it is non-vanishing. The two phases are disconnected classically. The second example is the {gamma}=1/3(radiation) case. With the help of earlier work this matter can be identified with a D0-brane in string theory. In this case, due to the absence of the scale factor duality and the ...

2007-10-21

43

Concept of time in physics. Physical and philosophical investigations on the concept of time in classical and relativistic physics. Der Zeitbegriff in der Physik. Physikalische und philosophische Untersuchungen zum Zeitbegriff in der klassischen und in der relativistischen Physik  

Energy Technology Data Exchange (ETDEWEB)

In this book the notion of time in classical physics and relativity theory is discussed. After a criticism of the absolute time some alternative measures of time in mechanics are considered. Thereafter the problem of equal time at different points of the space as well as the time in different inertial systems are considered. In this framework the clock paradox is discussed. Then the Lorentz transformation is considered. Thereafter the reconstruction of the absolute time in relativity theory is described. Finally the notion of time in general relativity theory is considered.

1980-01-01

44

np{yields}d{gamma} for big-bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The cross section for np{yields}d{gamma} is calculated at energies relevant to big-bang nucleosynthesis using the recently developed effective field theory that describes the two-nucleon sector. The E1 amplitude is computed up to N{sup 3}LO and depends only upon nucleon-nucleon phase shift data. In contrast, the M1 contribution is computed up to next-to-leading order, and the four-nucleon-one-magnetic-photon counterterm that enters is determined by the cross section for cold neutron capture. The uncertainty in the calculation for nucleon energies up to E{approx}1 MeV is estimated to be (less-or-similar sign)4%. (c) 1999 The American Physical Society.

1999-12-01

45

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

46

Seeking nature of God in Big Bang T1 the secrets to the beginning of the universe could lie underground in Switzerland.  

CERN Multimedia

Joanna Geary joined a Birmingham University team of scientists working on the project in Geneva. Simond Hadley took the pictures. "The most exciting thing of all" says professor Peter Watkins with a smile, "is we have absolutely no idea what will happen until we switch it on."

2008-01-01

47

Relativistic kinetics of baryon production in the big bang  

Energy Technology Data Exchange (ETDEWEB)

The baryogenesis process in the early hot universe is investigated by means of relativistic kinetic theory. An exact solution to the kinetic equations for supermassive bosons serves to refine previous results: the optimum baryon-production domain is now complemented by bosons of low mass, thus removing the cosmological lower bound that had limited the mass of superheavy bosons. 14 references.

1985-08-01

48

Loop quantum cosmology of Bianchi type IX models  

International Nuclear Information System (INIS)

The loop quantum cosmology 'improved dynamics' of the Bianchi type IX model are studied. The action of the Hamiltonian constraint operator is obtained via techniques developed for the Bianchi type I and type II models, no new input is required. It is shown that the big bang and big crunch singularities are resolved by quantum gravity effects. We also present effective equations which provide quantum geometry corrections to the classical equations of motion.

2010-08-15

49

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to ...

1999-03-01

50

Real-time neutron diffraction measurements of the kinetics of first-order phase transitions  

International Nuclear Information System (INIS)

The wide-angle neutron diffractometer recently installed at the HFIR has the capability of performing time-resolved or time-slicing measurements. One of the interesting problem areas the authors have explored using this time-slicing function of the diffractometer is the kinetics of structural changes occurring after a temperature jump across a value at which a first-order phase transition occurs. Two measurements of this sort have been carried out: the phase III to II transition in RbNO_3 and the transition between the alpha and beta phases in Sn.

1985-03-01

51

Time-resolved measurement of a self-amplified free-electron laser  

International Nuclear Information System (INIS)

We report on a time-resolved measurement of self-amplified spontaneous emission free-electron laser (FEL) pulses. We observed that the spikes in such FEL pulses have an intrinsic positive chirp and the energy chirp in the electron bunch mapped directly into the FEL output. The measurement also provides rich information on the statistics of the FEL pulses.

2003-07-11

52

Aerodynamic force measurement on a large-scale model in a short duration test facility  

International Nuclear Information System (INIS)

A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. ...

2005-03-01

53

Void fraction distribution measurement in two-phase flow by real-time neutron radiography and real-time image processing  

International Nuclear Information System (INIS)

A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).

1996-07-01

54

Unraveling gene regulatory networks from time-resolved gene expression data -- a measures comparison study  

UK PubMed Central (United Kingdom)

BackgroundInferring regulatory interactions between genes from transcriptomics time-resolved data, yielding reverse engineered gene regulatory networks, is of paramount importance...Full Text Available

55

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

56

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

57

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

58

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

59

MAIN RESULTS OF ATMOSPHERIC FINE STRUCTURE PARAMETER OBSERVATION ...  

Science.gov (United States)

results of motion energy spectral density measurements in the upper atmosphere for the time interval of 5 minutes to 12 hours, in ...

60

Evaluation of a Biometric Keystroke Typing Dynamics ...  

Science.gov (United States)

... i3a TYPT OF REPORT 13b TIME COVERED 14 DATE OF RF ... automation system when used in conjunction with other standard security measures. ...

1992-03-01

61

A PC-Based Imaging System for the Naval Postgraduate ...  

Science.gov (United States)

... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...

1989-09-01

62

Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions  

International Nuclear Information System (INIS)

Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).

1975-09-15

63

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme ...

1988-09-01

64

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of ...

1988-01-01

65

An alternative explanation of the COBE data  

Energy Technology Data Exchange (ETDEWEB)

The COBE data on cosmic background radiation (CBR) isotropy and spectrum are generally considered to be explicable only in the context of the Big Bang theory and to be confirmation of that theory. However, this data can also be explained by an alternative, non-Big Bang model which hypothesizes an intergalactic radio-absorbing and scattering medium. Dense, force-free magnetic filaments generated by quasars, active galactic nuclei and Herbig-Haro objects can remain stable in the intergalactic medium for many Gy. They will be opaque to radiation with wavelengths longer than 100--400 microns, and essentially transparent to shorter wavelengths. They are thus capable of thermalizing and isotropizing the cosmic background radiation, and of accounting for the observed decrease of radio luminosity of galaxies within increasing distance from earth. A simple, inhomogeneous model of such an absorbing medium can reproduce both the isotropy and spectrum of ...

1994-12-31

66

Method for determining the concentration of atomic species in gases and solids  

Energy Technology Data Exchange (ETDEWEB)

Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a plasma containing the species after a sufficient time period has elapsed after the generation of the plasma and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample.

1999-01-01

67

Fuzzy performance measurement of a supply chain in manufacturing companies  

British Library Electronic Table of Contents (United Kingdom)

This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...

2011-01-01

68

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

69

Protostar Formation in the Early Universe  

CERN Document Server

The nature of the first generation of stars in the Universe remains largely unknown. Observations imply the existence of massive primordial stars early in the history of the universe, and the standard theory for the growth of cosmic structure predicts that structures grow hierarchically through gravitational instability. We have developed an ab initio computer simulation of the formation of primordial stars that follows the relevant atomic and molecular processes in a primordial gas in an expanding universe. The results show that primeval density fluctuations left over from the Big Bang can drive the formation of a tiny protostar with a mass of just one percent that of the sun. The protostar is a seed for the subsequent formation of a massive primordial star.

2008-01-01

70

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

71

On the space-time scales of the surface solar radiation field  

Energy Technology Data Exchange (ETDEWEB)

The characteristic space-time scales of surface solar radiation fields measured by the 111-instrument ME-SONET in Oklahoma are estimated after removal of the diurnal cycle. These estimates of {open_quotes}within-day{close_quotes} are used to deduce the representativeness of surface solar radiation measurements measurement site as a function of time-averaging interval. Nomograms of the relation between point measurements and area averages are given for different space-time-averaging intervals. Examples from the nomograms show, for instance, that under conditions of low mean radiation (cloudy days), the central site point measurements are representative of a spatial area the size of a T42 GCM grid box (280 km X 280 km) if one uses hourly averages and is willing to accept a correlation of 0.45 between area average and point ...

1998-01-01

72

Timings of high voltage circuit-breaker  

Energy Technology Data Exchange (ETDEWEB)

The reliability of an electrical power system is influenced by the operation of circuit-breaker (CB). A good indicator of circuit-breaker condition is its switching time. Based on it some of the critical circuit-breaker irregularities can be detected and removed before they develop to a failure. In this paper, the evaluation of time measurements (timings) in case of different failures will be carried out for two circuit-breaker solutions, i.e. with spring and hydraulic drive. Moreover, the relationships between switching time and failure type/location will be derived. Thereby, the influence of failure trend will also be taken into account. (author)

2008-12-15

73

Time Average Aerodynmic Forces and Moments on a National Model of a Semi-Submersible Offshore Rig. Part 1. Measurements. Part 2. Analysis of Results for the Basic Model.  

Science.gov (United States)

Wind-tunnel measurements were taken of the time-average aerodynamic forces and moments on a notional model of a semi-submersible offshore drilling rig at two heights and at various attitudes to the wind. Attempts were made to analyze the separate effects ...

1982-01-01

74

Monitoring interfacial dynamics by pulsed laser techniques. [Annual report  

Energy Technology Data Exchange (ETDEWEB)

Goal was developing optical methods for study of dynamic processes at the electrode/electrolyte interface. In the past year, optical second harmonic generation was used for time-resolved measurements of thallium deposition on Cu(111). The studies of carrier dynamics in photo-excited materials have involved both steady-state and picosecond time-resolved luminescence measurements following photoexcitation of the semiconductor material.

1992-12-31

75

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

76

A time-resolved optical study of the avalanche and streamer formation in atmospheric nitrogen  

Energy Technology Data Exchange (ETDEWEB)

This work deals with a time-resolved optical study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen. The authors present the results obtained for nitrogen, from experiments and two-dimensional model simulations. This model is used to obtain a better insight in the relevant mechanisms and processes by a comparison of measurements and simulation data. The trends of externally measured quantities correspond with those predicted by the model.

1996-12-31

77

Measurement of \\chi_cJ--> K+K-K+K-  

CERN Document Server

Using 14M psi(2S) events taken with the BES-II detector, chi_cJ-->K+K-K+K- decays are studied. For the four-kaon final state, the branching fractions are B(chi_c0,1,2 -->K+K-K+K-)=(3.47\\pm 0.22\\pm 0.48)\\times 10^{-3}, (0.68\\pm 0.13\\pm 0.10)\\times 10^{-3}, and (1.88\\pm 0.18\\pm 0.28)\\times 10^{-3}. For the \\phi K+K- final state, the branching fractions, which are measured for the first time, are B(chi_c0,1,2-->\\phi K+K-)=(1.02\\pm 0.22\\pm 0.15)\\times 10^{-3}, (0.44\\pm 0.14\\pm 0.07)\\times 10^{-3}, and (1.46\\pm 0.21\\pm 0.22)\\times 10^{-4}. For the \\phi\\phi final state, B(chi_{c0,2}-->\\phi\\phi)=(0.94\\pm 0.21\\pm 0.14)\\times 10^{-3} and (1.48\\pm 0.26\\pm 0.23)\\times 10^{-3}.

2006-01-01

78

Experimental Comparison of Representation Methods and Distance Measures for Time Series Data  

CERN Document Server

The previous decade has brought a remarkable increase of the interest in applications that deal with querying and mining of time series data. Many of the research efforts in this context have focused on introducing new representation methods for dimensionality reduction or novel similarity measures for the underlying data. In the vast majority of cases, each individual work introducing a particular method has made specific claims and, aside from the occasional theoretical justifications, provided quantitative experimental observations. However, for the most part, the comparative aspects of these experiments were too narrowly focused on demonstrating the benefits of the proposed methods over some of the previously introduced ones. In order to provide a comprehensive validation, we conducted an extensive experimental study re-implementing eight different time series representations and nine similarity ...

2010-01-01

79

Cosmic time dilation: The clock paradox revisited  

Energy Technology Data Exchange (ETDEWEB)

The relativistic time dilation is reviewed in a cosmological context. We show that a clock or twin paradox does not arise if cosmic time is properly taken into account. The receding galaxy background provides a unique frame of reference, and the proper times of geodesic as well as accelerated observers can be linked to the universal cosmic time parameter. This suggests to compare the proper time differentials of the respective observers by determining their state of motion in the galaxy grid. In this way, each observer can figure out whether his proper time is dilated or contracted relative to any other. In particular one can come to unambiguous conclusions on the aging of uniformly moving observers, without reference to asymmetries in measurement procedures or accelerations they may have undergone.

2004-05-01

80

Optimizing the acquisition time profile for a planar integral measurement system with a spinning slat collimator  

International Nuclear Information System (INIS)

This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered ...

2005-09-01

81

Proton Form Factors measurements in the time-like region  

Energy Technology Data Exchange (ETDEWEB)

I present an overview of the measurement of the proton form factors in the time-like regiun. BABAR has recently measured with great accuracy the e{sup +} e{sup -} {yields} p p-bar reaction from productiun threshold up to an energy of {approx} 4.5 GeV; finding evidence for a ratio of the electric to magnetic form factur greater than unity, contrary to expectation. In agreement with previous measurements. BABAR confirmed the steep rise uf the magnetic form factor close to the p p-bar mass threshold, suggesting the possible presence of an under-threshuld N N-bar vector state. These and uther open questiuns related to the nucleon furm factors both in the time-like and space-like region, wait for more data with different experimental techniques to be possibly solved.

2007-05-15

82

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

83

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

84

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

85

Real time control of micro-machine system using micro-computer based fuzzy logic power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.

1994-12-01

86

Excess transit time as a function of burst current in an exploding bridgewire detonator  

Energy Technology Data Exchange (ETDEWEB)

Transit time, the time from bridgewire burst until breakout of detonation from the output pellet of an exploding bridgewire detonator, was measured as a function of burst current. From this data, in conjunction with known equations for run distance versus pressure, unreacted explosive Hugoniots, and detonation properties of the initial pressing pellet, the run distance in the initial pressing explosive pellet and shock pressure from the exploding bridgewire were determined, both as a function of burst current.

1990-01-01

87

Temperature and time-dependence of the elastic moduli of Pu and Pu-Ga alloys  

International Nuclear Information System (INIS)

In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .

2007-10-11

88

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

89

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

90

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

91

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

92

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

93

The CTOF measurements and Monte Carlo analyses of neutron spectra for backward direction from iron target irradiated by protons with energies from 400 to 1200 MeV  

CERN Document Server

A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.

2009-01-01

94

Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

1994-12-31

95

Patient Monitoring during Mechanotherapy Based on Electrocutaneous Impedance Measurement  

British Library Electronic Table of Contents (United Kingdom)

Patient monitoring during mechanotherapy based on electrocutaneous impedance measurement is discussed. Methods implemented by the Alpharhythmica computer-assisted system are described. Mechanotherapy modifies electrocutaneous impedance as compared to other parameters: heart rate, arterial pressure, and body temperature. Real time criteria of mechanotherapy efficacy based on electrocutaneous impedance measurement are suggested. Results of electrocutaneous impedance monitoring are presented.

2011-01-01

96

Optical measurement of electron bunching in vacuum  

International Nuclear Information System (INIS)

We report the homodyne detection of phase modulation sidebands induced on a laser beam by a coherently bunched electron beam. This provides a sensitive and nonperturbing measurement of complex Fourier time series components of the electron density. A proof-of-principle measurement of the microwave frequency component of electron density in a crossed-field device, which agrees well with a calculation of the same quantity, is reported.

97

Experience with a digital noise analysis system in subcriticality measurements on a mockup of the FFTF  

Science.gov (United States)

From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)

1973-01-01

98

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

Energy Technology Data Exchange (ETDEWEB)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))

1994-06-01

99

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

International Nuclear Information System (INIS)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).

1994-01-01

100

True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase  

Energy Technology Data Exchange (ETDEWEB)

A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface ...

2000-03-01

101

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a ...

2009-07-20

102

Physical and mathematical description of Nuclear Weapons Identification System (NWIS) signatures  

Energy Technology Data Exchange (ETDEWEB)

This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the {sup 252}Cf source ionization chamber; (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the full five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt%, {sup 235}U) metal casting for storage are presented to illustrate ...

1997-09-26

103

Physical and Mathematical Description of Nuclear Weapons Identification System (NWIS) Signatures  

Energy Technology Data Exchange (ETDEWEB)

This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the 252Cf source ionization chamber (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the fill five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt 0/0, 235U) metai casting for storage are presented to illustrate the ...

1997-09-26

104

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

105

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

106

Measurement of the energy dependence of the neutron fission cross section of /sup 242/Am/sup m/  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.

1981-03-01

107

Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF  

International Nuclear Information System (INIS)

An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.

2010-01-01

108

OTVE turbopump condition monitoring, task E. 5. Final report, October 1988-September 1989  

Energy Technology Data Exchange (ETDEWEB)

Recent work has been carried out on development of isotope wear analysis and optical and eddy current technologies to provide bearing wear measurements and real time monitoring of shaft speed, shaft axial displacement and shaft orbit of the Orbit Transfer Vehicle hydrostatic bearing tester. Results show shaft axial displacement can be optically measured (at the same time as shaft orbital motion and speed) to within 0.3 mils by two fiberoptic deflectometers. Evaluation of eddy current probes showed that, in addition to measuring shaft orbital motion, they can be used to measure shaft speed without having to machine grooves on the shaft surface as is the usual practice for turbomachinery. The interim results of this condition monitoring effort are presented.

1989-08-01

109

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future ...

110

A Fast Ionization Chamber for Fission Cross-Section Measurements at n(_)TOF  

International Nuclear Information System (INIS)

An ionization chamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, ...

2008-09-01

111

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of ...

2004-04-01

112

The Path to Metallicity: Synthesis of CNO Elements inStandard BBN  

Energy Technology Data Exchange (ETDEWEB)

We perform an analysis of the production of elements with mass number A {ge} 12 in a standard Big Bang Nucleosynthesis scenario. The goal is to provide a more accurate estimate of the very low and yet poorly explored abundance of such elements, relevant for the pristine Population III stars. We examine the synthesis channels for these elements in a critically revised and updated version of the Wagoner-Kawano code, as well as in a further enlarged version including four additional nuclides and a significantly extended nuclear network. Our results show no major discrepancies with the ones obtained using a smaller nuclear network. The robustness of the standard predictions--the early generation of star developed in a metal-free environment--is confirmed.

2007-02-12

113

Ultrasonic Acoustic Emissions from the Sapwood of Thuja occidentalis Measured inside a Pressure Bomb 1  

UK PubMed Central (United Kingdom)

An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available

1984-04-01

114

Sustained metabolic scope.  

UK PubMed Central (United Kingdom)

Sustained metabolic rates (SusMR) are time-averaged metabolic rates that are measured in free-ranging animals maintaining constant body mass over periods long enough that metabolism is fueled by food...Full Text Available

1990-03-01

115

Structural and functional aspects of radiation adrenalopathy  

Energy Technology Data Exchange (ETDEWEB)

As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.

1986-01-01

116

QTL analysis of measures of mouse home-cage activity using B6/MSM consomic strains  

UK PubMed Central (United Kingdom)

The activity of mice in their home cage is influenced greatly by the cycle of light and dark. In addition, home-cage activity shows remarkable time-dependent changes that result in a prominent temporal...Full Text Available

2010-10-01

117

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

Energy Technology Data Exchange (ETDEWEB)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

1983-01-01

118

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

International Nuclear Information System (INIS)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

119

Measurements of plasma density profiles driven by p-polarized microwaves  

Energy Technology Data Exchange (ETDEWEB)

For supersonic plasma flow velocities, instead of the usual shelf-step profile seen for subsonic flow, an overdense bump and cavity is observed. The profile is stable for long times even for moderate power microwaves.

1983-07-11

120

MAGIC - Multi Anode Gas Ionization Chamber  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))

1994-12-01

121

Effect of Length of Time before Incorporation on Survival of Pathogenic Bacteria Present in Livestock Wastes Applied to Agricultural Soil  

UK PubMed Central (United Kingdom)

In response to reports that the contamination of food can occur during the on-farm primary phase of food production, we report data that describes a possible cost-effective intervention measure. The...Full Text Available

2004-09-01

122

Detection of cellular responses to toxicants by dielectrophoresis  

UK PubMed Central (United Kingdom)

The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured...Full Text Available

2002-08-31

123

A simple nomogram for sample size for estimating sensitivity and specificity of medical tests  

UK PubMed Central (United Kingdom)

Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available

2010-11-01

124

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those ...

1995-03-11

125

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those ...

1995-03-01

126

Delayed-neutron energy spectra following thermal-neutron-induced fission of Pu-239  

Energy Technology Data Exchange (ETDEWEB)

Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was ...

1987-01-01

127

Multidetector-row helical CT: analysis of time management and workflow  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and programming was most ...

2002-03-01

128

Transient-diffusion measurements of radon. Practical interpretation of measured data  

International Nuclear Information System (INIS)

The mathematical calculation to obtain a radon diffusion coefficient from measured radon transient-diffusion data is usually done by fitting a difference equation to the data. The difference equation is obtained through transformation of the time-dependent diffusion equation based on Fick's law. But, actual measured transient-diffusion data often have much scatter. Therefore just fitting over the whole range of the measured data through the method of least squares may not always be valid, because the method offers mathematical interpretation rather than a physical one. Instead, the actual radon diffusion coefficients must be otherwise obtainable from measured radon transient data. Taking this viewpoint, the present paper claims that about a 90% leveling-off time is often easily discernible regardless of the shape of the radon transient curve obtained from the ...

2007-07-01

129

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, ...

1997-02-01

130

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

131

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

132

A study on the power system stabilizer using discrete-time adaptive sliding mode control  

Energy Technology Data Exchange (ETDEWEB)

In this paper the newly developed discrete-time adaptive sliding mode control method is proposed and applied to the power system stabilization problem. In contrast to the conventional continuous-time sliding mode controller, the proposed method is developed in the discrete-time domain and based on the input/output measurements instead of the continuous-time and the full-states feedback, respectively. Because the proposed control method has the adaptivity property in addition to the natural robustness property of the sliding mode control, it is possible to design the power system stabilizer which can overcome both the minor variations of the parameters of the power system and the diverse operating conditions and faults of the power system. Mathematical proof and the various computer simulations are done to verify the performance and stability of the proposed method. (author). 14 ...

1996-02-01

133

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

134

Directional wind-measurement derived from elastic backscatter lidar data in real-time  

Energy Technology Data Exchange (ETDEWEB)

The development of a capability to infer wind velocities simultaneously at a number of ranges along one direction in real time is described. The elastic backscatter lidar data used was obtained using the XM94 lidar, developed by Los Alamos National Laboratory for the US Army Chemical and Biological Detection Command. In some respects this problem is simpler than measuring wind velocities on meso-meteorological scales. Other requirements, particularly high temporal fidelity, have driven the development of faster software algorithms and suggested opportunities for the evolution of the hardware.

1996-04-01

135

A Sequential Problem in Decentralized Detection with Communication  

CERN Document Server

A sequential problem in decentralized detection is considered. Two observers can make repeated noisy observations of a binary hypothesis on the state of the environment. At any time, observer 1 can stop and send a final binary message to observer 2 or it may continue to take more measurements. Every time observer 1 postpones its final message to observer 2, it incurs a penalty. Observer 2's operation under two different scenarios is explored. In the first scenario, observer 2 waits to receive the final message from observer 1 and then starts taking measurements of its own. It is then faced with a stopping problem on whether to stop and declare a decision on the hypothesis or to continue taking measurements. In the second scenario, observer 2 starts taking measurements from the beginning. It is then faced with a different stopping problem. At any ...

2009-01-01

136

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed ...

1996-10-01

137

The application of virtual instruments technique in U-H_2 experimental system  

International Nuclear Information System (INIS)

The concept of the modern data acquisition system and some functional specialties of the programming software--Visual Basic 6.0 are introduced. The construction and theory of the hardware and the designing principle of the software are described. Experimental results showed that the real-time data acquisition rate was as high as 10 times per second in the system. And the relative standard uncertainty of the measurement was less than 0.5%. (authors)

2004-11-01

138

On some problems caused by wavelet filtering in calculated spectra  

Energy Technology Data Exchange (ETDEWEB)

It is shown that de-noising a measured time signal by wavelet technique produces a rather good result in time domain, while it has unwanted consequences in spectrum estimation. Therefore it can be used for reconstruction of the picture of the physical process, but it should be avoided, when the aim is to reveal eigenfrequencies or transient behaviour of the spectra.

1999-08-01

139

Multiway real-time PCR gene expression profiling in yeast Saccharomyces cerevisiae reveals altered transcriptional response of ADH-genes to glucose stimuli  

UK PubMed Central (United Kingdom)

BackgroundThe large sensitivity, high reproducibility and essentially unlimited dynamic range of real-time PCR to measure gene expression in complex samples provides the opportunity...Full Text Available

140

Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)  

Energy Technology Data Exchange (ETDEWEB)

The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.

1994-12-01

141

Long-range correlation analysis of earthquake-related geochemical variations recorded in Central Italy  

Energy Technology Data Exchange (ETDEWEB)

The long-range correlation properties in the hourly time variability of geochemical signals measured in a 70 m depth well at Triponzo (Umbria region), are investigated by the detrended fluctuation analysis (DFA). DFA is a data processing method that allows for the detection of scaling behaviors in observational time series even in the presence of non-stationarities. The procedure adopted has allowed for the unambiguous identification of possible correlations among the recorded signals and local earthquakes.

2004-07-01

142

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

143

An instrument for measuring spatial and time characteristics of sea agitation in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.

1981-01-01

144

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

145

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

146

Observation of p pbar pi^0 and p pbar eta in psi' decays  

CERN Document Server

The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.

2005-01-01

147

Micropulse Lidar (MPL) Handbook  

Energy Technology Data Exchange (ETDEWEB)

The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.

2006-05-01

148

Tracer distributions in the Tropical Lower Stratosphere.  

Environmental Research Database

DescriptionMeasurements of halocarbons (CFCs and other halogen-containing compounds) in the tropical stratosphere will be made from a long duration MIR balloon. The balloon and instruments are capable of flying for three or more weeks in which time they will circum-navigate the globe. As the balloon rises each morning and falls each evening, measurements of halocarbons will be made every few hundred meters between about 20 and 30 km. In total it is hoped that over 40 such vertical profiles will be obtained [continued...

2009-01-31

149

Simulation of the skim-off method in radon measurement by activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Simulation of the skim-off method for radon measurement by activated charcoal has been carried out by the finite elements method. The variation of radon concentration with peak appearance has been simulated. The thickness of the layer of charcoal removed after exposure and the time of peak appearance have been varied. For the charcoal and canister geometry used, the best results were found when the thickness of the layer removed was 1.72 mm.

2001-07-01

150

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

151

Measurements of nuclear emulsion tracks by means of a picture analysis system  

Energy Technology Data Exchange (ETDEWEB)

A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.

1986-01-01

152

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

153

Measurement of gas flow velocities by laser-induced gratings  

Energy Technology Data Exchange (ETDEWEB)

Time resolved light scattering from laser-induced electrostrictive gratings was used for the determination of flow velocities in air at room temperature. By measuring the velocity profile across the width of a slit nozzle we demonstrated the high spatial resolution (about 200 mm) of this novel technique. (author) 3 figs., 1 ref.

1999-08-01

154

Loss of light charged particles by nuclear interactions in BaF[sub 2] crystals  

Energy Technology Data Exchange (ETDEWEB)

The nuclear interaction probability of light charged particles in BaF[sub 2] crystals has been studied as a function of the incident particle energy. Light charged particles were identified in charge and mass by measuring their magnetic rigidity and their time-of-flight. The percentage of particles undergoing nuclear interactions has been measured for particles of charge from Z=1 to Z=6 and the experimental data are compared with the results of a model calculation. (orig.)

1993-07-15

155

Improved measurement of $\\psi (2S)$ decays into $\\tau ^{+}\\tau ^{-}$  

CERN Document Server

Using 14M $\\psi (2S)$ events collected at BESII, the branching fraction of $\\psi (2S)\\to \\tau ^{+}\\tau ^{-}$ is measured to be $Br_{\\tau \\tau}=(3.10\\pm 0.21\\pm 0.38)\\times 10^{-3}$, where the first error is statistical and the second is systematic.

2006-01-01

156

Experience with protection and restoration measures on reinforced concrete structures; Erfahrungen mit Schutz- und Instandsetzungsmassnahmen an Stahlbeton-Konstruktionen  

Energy Technology Data Exchange (ETDEWEB)

Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)

2008-07-01

157

Diagnostic measurements on the great machines conditions of lignite surface mines  

Science.gov (United States)

An analysis of the diagnosis of loading and service dependability of a rail-mounted excavator used in surface lignite mining is described. Wheel power vibrations in electric motor bearings and electric motor input bearings to the gearbox were measured in situ, in horizontal, vertical, and axial directions. The data were analyzed using a mathematical relationship. The results are presented in a loading diagram that shows the deterioration and the acceptable lower bound of machine conditions over time. Work is continuing. 5 refs., 1 fig.

2005-07-01

158

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

159

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

160

Core power distribution measurement and data processing in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.

161

Fixed time and fixed point observation of environmental radioactivities in Tokyo  

Energy Technology Data Exchange (ETDEWEB)

A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon ...

1997-03-01

162

Development of BWR core flow measurement technology using in-core neutron fluctuating signals  

Energy Technology Data Exchange (ETDEWEB)

The extensive work on the measurement technology of total and local flow rates in BWR core has been performed using in-core neutron fluctuating signals. Based on a large amount of actual data acquired from commercial BWR plants in operation, physical interpretation was discussed on the transit time of the neutron fluctuating signals. The new findings against the logical inconsistency of the transit time between the different LPRM detector positions lead to a promised core flow measurement algorithm using in-core neutron fluctuating signals. The advanced on-line core flow measurement system was developed and tested during the startup phase of the first ABWR. The measurement test results demonstrate the present core flow measurement system within the errors of 5 through 10% over the wide operating area besides the capability for the local void ...

1997-09-01

163

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

164

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

165

Thermonuclear burst physics with RXTE  

CERN Document Server

Recently we have made measurements of thermonuclear burst energetics and recurrence times which are unprecedented in their precision, largely thanks to the sensitivity of the Rossi X-ray Timing Explorer. In the "Clocked Burster", GS 1826-24, hydrogen burns during the burst via the rapid-proton (rp) process, which has received particular attention in recent years through theoretical and modelling studies. The burst energies and the measured variation of alpha (the ratio of persistent to burst flux) with accretion rate strongly suggests solar metallicity in the neutron star atmosphere, although this is not consistent with the corresponding variation of the recurrence time. Possible explanations include extra heating between the bursts, or a change in the fraction of the neutron star over which accretion takes place. I also present results from 4U 1746-37, which exhibits regular burst ...

2004-01-01

166

Liquid metal flow measurement by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).

1996-07-21

167

Liquid metal flow measurement by neutron radiography  

International Nuclear Information System (INIS)

Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).

1996-07-01

168

First measurements of J/Psi decays into $\\Sigma^+ \\bar{\\Sigma}^-$ and $\\Xi^0 \\bar{\\Xi}^0$  

CERN Document Server

Based on 58 million J/Psi events collected with the BESII detector at the BEPC, the baryon pair processes J/Psi to $\\Sigma^+ \\bar{\\Sigma}^-$ and J/Psi to $\\Xi^0 \\bar{\\Xi}^0$ are observed for the first time. The branching fractions are measured to be ${\\cal B}(J/Psi to \\Sigma^+ \\bar{\\Sigma}^-)=(1.50\\pm 0.10\\pm 0.22)\\times 10^{-3}$ and ${\\cal B}(J/Psi to \\Xi^0 \\bar{\\Xi}^0)=(1.20\\pm 0.12\\pm 0.21)\\times 10^{-3}$, where the first errors are statistical and the second ones are systematic.

2008-01-01

169

Enamel-Calibrated Lamellar Bone Reveals Long Period Growth Rate Variability in Humans  

British Library Electronic Table of Contents (United Kingdom)

Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...

2011-01-01

170

Delayed neutron yields: Time dependent measurements and a predictive model  

Energy Technology Data Exchange (ETDEWEB)

The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.

1981-03-01

171

Visualization and void fraction measurements of refrigerant flow in a refrigerator by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)

2000-07-01

172

Subsidence model of spoil bank surface  

Energy Technology Data Exchange (ETDEWEB)

Evaluates a mathematical model that describes subsidence of spoil banks in surface brown coal mines. The model is based on the results of geodetic surveys carried out in 1974-1985. Twelve spoil banks from 4 to 61 m high were considered. Ground subsidence and deformation along 12 measuring lines and 6 measuring networks were measured. Ground subsidence during a period of 18 to 241 months was evaluated using regression analysis. The mathematical model considered effects of spoil bank design (number and thickness of rock layers), rock mechanical and physical properties and service time. 6 refs.

1989-01-01

173

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

174

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

175

Measurement error modeling and nutritional epidemiology association analyses  

British Library Electronic Table of Contents (United Kingdom)

Abstract This article summarizes the results of a Nutrient Biomarker Study in the Women's Health Initiative, and its application to studies of the association between energy and protein consumption and the risk of major cancers and cardiovascular diseases. The presentation emphasizes measurement error modeling and related data analysis methods, since addressing measurement issues appears to be central to these topics and to progress in nutritional epidemiology more generally. The manner in which body mass index is modeled in disease association analysis is particularly challenging, since it could serve as a mediator or as a confounder of the association, and at the same time contributes valuably to energy and protein consumption assessment. A hazard ratio parameter estimation procedure tha...

2011-01-01

176

In situ monitoring of grouted electrolytes  

Energy Technology Data Exchange (ETDEWEB)

Cement-based composites are widely used in applications which demand long-term service life. One important example is in immobilization matrices for low-level radioactive and other hazardous wastes, which demands long-term retention and durability. The authors describe conductivity measurements of grouts flooded with water and in contact with a sink that consists of pure water. The conductivity measurements were designed and carried out in parallel with present quality verification methods and standard leach tests of the nuclear waste management industry. For the first time, the authors show that the method of replacing intrusive chemical analysis with conductivity measurements of the leaching samples yields equivalent results.

1996-04-01

177

Determining nuclear morphology using an improved angle-resolved low coherence interferometry system  

Science.gov (United States)

We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.

2003-12-01

178

Dephasing of two electron states in a double quantum-dot system irradiated by a microwave field with a nearby Quantum Point Contact  

CERN Document Server

In this work we study the dephasing mechanism of a double quantum-dot system, which includes two electrons and a nearby quantum point contact (QPC) as a measurement device. We obtain that the QPC-induced decoherence is on time scales of microseconds. We also find that the electrons will be delocalized after continuous measurement, irrespectively of the initial conditions, and the frequent repeated measurements will localize the system, which is consistent with the quantum Zeno effect. Further, we consider the situation that the double quantum-dot system is irradiated by a microwave field.

2008-01-01

179

Continuous measurement of blast-furnace coke moisture  

International Nuclear Information System (INIS)

After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).

180

Final Scientific EFNUDAT Workshop  

ScienceCinema

...and it's really a pleasure to ...you and ...and for ...was shelled and then doses of pleasure for me to ...and my director general ...? and journal article ? ...but and yeah well that's um ? ...and ...and what could be achieved ? what might be the consequences ...? and ...and ...and ...and ...and ...structural because and ...over and hopefully is also serve the purpose to get ...principles and ...and ...and ...how to use them and future ...and and that ...and purposes and that's very important ...you and ...and ...and in the future ? and yeah ...true and ...and ...just and and and and and the order of nuclear physics a ...useful and ...too much ? and ...portable comes from and ...and ...and ...and ...no more ? how to knowledge and the and ...and ...and and keep ever seen all of all ? ...and ...and ...and what you're ...and ...and ...and you and ...and ...and ...and so when you keep that and and ...and ...? and ...and ...and ...the problems and the other side ? ...door and a ...and ...

181

Vapor fraction measurements in a steam-water duct at atmospheric pressure using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.

1994-11-11

182

Mass measurement of neutron-rich isotopes from [sup 51]Ca to [sup 72]Ni  

Energy Technology Data Exchange (ETDEWEB)

The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)

1994-07-01

183

Mass measurement of neutron-rich isotopes from "5"1Ca to "7"2Ni  

International Nuclear Information System (INIS)

The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).

184

Compare analysis of efficiency of using of digital and analog regimes of registration of radiation in radiometric systems of radiation thickness measuring  

International Nuclear Information System (INIS)

A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed

185

Matrix diffusion studies by electrical conductivity methods. Comparison between laboratory and in-situ measurements  

Energy Technology Data Exchange (ETDEWEB)

Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study compares laboratory ...

1998-09-01

186

Electron flow in the SABRE linear induction adder in positive polarity  

International Nuclear Information System (INIS)

In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have extended the work on this ...

1993-05-17

187

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this ...

2005-11-15

188

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first ...

1999-11-01

189

Observations of unsaturated water flow using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-08-01

190

Observations of unsaturated water flow using real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-01-01

191

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

192

Electronic imaging system for neutron radiography at a low power research reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-15

193

Electronic imaging system for neutron radiography at a low power research reactor  

International Nuclear Information System (INIS)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-01

194

Deterministic Chaos in Radon Time Variation  

International Nuclear Information System (INIS)

Radon concentrations were continuously measured outdoors, in living room and basement in 10-minute intervals for a month. The radon time series were analyzed by comparing algorithms to extract phase-space dynamical information. The application of fractal methods enabled to explore the chaotic nature of radon in the atmosphere. The computed fractal dimensions, such as Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (#lambda# ) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0time series, but the positive values of the #lambda# pointed out the grate sensitivity on initial conditions and appearing deterministic chaos by radon time variations. The calculated fractal dimensions of attractors indicated more influencing ...

2003-04-09

195

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

196

Performance of Alcator C-Mod core Thomson scattering system  

Energy Technology Data Exchange (ETDEWEB)

Design of the Alcator C-Mod Thomson scattering (TS) diagnostic is discussed and the results of the measurements are presented. The TS system has six spatial channels with observation volumes evenly distributed between the midplane and the edge of the plasma. Each channel is capable of measuring the electron density in the range N{sub e}=5{times}10{sup 19}{endash}5{times}10{sup 21} m{sup {minus}3} and temperature from T{sub e}=200 eV to 10 keV. A 30 Hz, 1.5 J per pulse Nd-YAG laser is employed allowing the measurements of evolution of T{sub e} and N{sub e} profiles during plasma shot. A laser beam position control and feedback system provides for the beam alignment stability and reliable electron density measurements. Examples of the core density and temperature profiles measured at different stages of the plasma evolution are discussed. ...

1999-01-01

197

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of {sup 86}Zr and {sup 85}Nb were measured and found ...

2009-07-01

198

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of "8"6Zr and "8"5Nb were measured and found to be in agreement with ...

2009-03-16

199

Tomography and Methods of Travel-Time Calculation for Regional Seismic Location  

Energy Technology Data Exchange (ETDEWEB)

We are developing a laterally variable velocity model of the crust and upper mantle across Eurasia and North Africa to reduce event location error by improving regional travel-time prediction accuracy. The model includes both P and S velocities and we describe methods to compute travel-times for Pn, Sn, Pg, and Lg phases. For crustal phases Pg and Lg we assume that the waves travel laterally at mid-crustal depths, with added ray segments from the event and station to the mid crustal layer. Our work on Pn and Sn travel-times extends the methods described by Zhao and Xie (1993). With consideration for a continent scale model and application to seismic location, we extend the model parameterization of Zhao and Xie (1993) by allowing the upper-mantle velocity gradient to vary laterally. This extension is needed to accommodate the large variation in gradient that is known to exist across Eurasia and North African. Further, we ...

2007-07-02

200

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of ...

1997-05-01

201

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. ...

2009-03-01

202

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. ...

2007-06-15

203

Benefits of the use of radioisotopes in industrial gauging and control  

International Nuclear Information System (INIS)

Since the radiometric measuring technique was introduced for industrial measuring and control engineering 15 to 20 years ago, the advantages of this technique have become more and more evident and have led to its world-wide application. In the last 15 to 20 years this method has become the standard one in this field. Its major advantages as compared with conventional methods are: contactless measurement; high reliability and accuracy; no mechanically moving parts; and no maintenance required. Despite higher investment costs the application of this method is paid off within a very short time owing to a higher output and the savings in maintenance costs. Some chemo-technical methods can be realized on a grand scale only when radiometric measuring equipment is used - e.g., urea plants, high-pressure polyethylene production. Especially in moisture measurements of ...

204

A high accuracy ultrasonic measurement method for nondestructive evaluation of residual stress in welded pipings  

Energy Technology Data Exchange (ETDEWEB)

Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The ...

1995-08-01

205

Valence mixing in rare earth compounds  

International Nuclear Information System (INIS)

The concepts of ''fast'' and ''slow'' time scale valence measurements are emphasized by a comparison of L/sub III/ absorption and Mossbauer effect measurements on the temperature induced valence change in EuPd/sub 2/Si/sub 2/. Further the authors show how synchrotron radiation based L/sub III/ measurements of the Ce-valence state can be used to demonstrate electronic structure trends under wide changes in chemical environment. The purpose of this paper is to provide an introduction to researchers in the People's Republic of China to the field of mixed valent rate earth compounds. They hope to illustrate some of the basic concepts in this field, how the field is contributing to the overall insight into the chemical physics of solids and finally how synchrotron radiation measurements in particular are playing a key role in this field.

206

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the ...

2007-07-01

207

Radon concentration measurements in bituminous coal mines  

Energy Technology Data Exchange (ETDEWEB)

Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

2005-07-01

208

Measuring air movement locally in the combustion chambers of a direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

Measurements of smoke and NO emissions from a direct-injection diesel engine have shown that they are indeed influenced by inlet port design, even though the swirl numbers for the ports may be identical. The swirl numbers of the three ports used (tangential port, helical port and helical port with masked valve) were measured on a steady-state test rig using a paddle-wheel anemometer and impulse swirl meter. Flow measurements were carried out under motoring conditions with a constant-temperature, hot-wire anemometer. Is was possible to find a correlation between flow data and exhaust data as far as the in-cylinder air motion over a certain time interval is concerned.

1983-02-01

209

Experimental investigation of wall static pressure fluctuations in parallel boiling flow  

International Nuclear Information System (INIS)

Measurements of the statistical characteristics of channel wall static pressure fluctuations in parallel one-component boiling flow are reported. The measurements span a wide range of local subcooling and vapor volume fraction, and correspond to flow regimes ranging from highly subcooled bubbly to saturated slug-annular. Vapor volume fraction measurements at the pressure measurement station are also reported in conjunction with visual observation of the flow structure. Variation of static pressure fluctuation intensity and spectral content with local thermal-hydraulic condition is demonstrated. Finally, it is suggested that diagnosis of local two-phase flow regime on the basis of (i) statistical characteristics of the pressure data, and (ii) time trace of pressure signal, may be possible. 15 refs.

1980-01-01

210

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

211

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

212

Reverse time migration: resolution in cross well seismic surveys; Migracao reversa no tempo: resolucao em levantamentos sismicos interpocos  

Energy Technology Data Exchange (ETDEWEB)

The standards mapping methods are limited by the lack of information between surface measures and wells profiles. The cross well seismic survey has proven being an effective high-resolution method for reservoirs characterization due its high frequency band. In this work, a 2-D finite differences algorithm for numerical cross well seismic simulation was developed, based in the approach of 2nd order for the time derivatives and 4th order for the space derivatives. In relation to the imaging techniques, it was introduced a reverse time migration method based in the solutions of the wave equation in time for cross well seismic data by the method of the finite differences exclusively. The results of reverse time migration has showed that layers with 90 cm thickness for P-waves could be visualized in migrated sections with excellent resolution. The high frequency cross well seismic data ...

2003-07-01

213

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These ...

214

A Bragg curve counter with an active cathode to improve the energy threshold in fragment measurements  

Energy Technology Data Exchange (ETDEWEB)

We have developed a Bragg curve counter (BCC) equipped with an active cathode to extend the energy acceptance to lower energies than for a conventional BCC to measure differential cross-sections of fragment production reactions induced by tens of MeV protons. The signal from the active cathode providing the timing signal of fragment incidence and the time difference signal between the cathode and anode gives information on the fragment range in the BCC on the basis of electron drift time. Utilization of the range information made possible identification of fragments less than 0.5 MeV/u that is lower than the identification threshold of a conventional BCC technique. After investigations on fundamental properties of a newly constructed BCC using heavy ion beams and alpha-particles, this method was applied successfully to a fragment production measurement for 70 MeV proton-induced ...

2008-05-01

215

Relationship between acute ozone responsiveness and chronic loss of lung function in residents of a high-ozone community  

Energy Technology Data Exchange (ETDEWEB)

The authors hypothesized that acute respiratory responsiveness to ozone predicts chronic lung injury from repeated exposure to ozone-containing air pollution. They tested this hypothesis in 164 middle-aged nonsmoking residents of an ozone-polluted community who underwent lung-function measurements during 1986 and 1987 (i.e., time 3). The time-3 study was a follow up of more comprehensive studies conducted in 1977--1978 (time 1) and in 1982--1983 (time 2). In contrast to the apparent rapid (i.e., {approx} 60 ml/y) decline in lung-function measurements between times 1 and 2, their subjects showed little change in forced vital capacity (FVC) or forced expired volume in 1 s (FEV{sub 1.0}) between times 2 and 3, and they experienced a normal decline between times 1 and 3. A subgroup (n = 45) underwent 2-h ...

1998-09-01

216

Tissue equivalent proportional counter real time neutron monitor  

International Nuclear Information System (INIS)

The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of ...

1978-10-25

217

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow ...

218

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly ...

2002-07-01

219

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

International Nuclear Information System (INIS)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly ...

2002-08-11

220

Food and chemical industry. Soy sauce and chemical engineering; Shokuhinn to kagaku kogaku. Shoyu to kagaku kogaku  

Energy Technology Data Exchange (ETDEWEB)

The buckwheat soup is a mixture of seasonings such as soy sauce, sweet sake, sugar and the like and stock of dried bonito. This paper describes an analysis of the stock manufacturing step, an important step in the manufacture of buckwheat soup, and the setting of stock extraction conditions on the basis of this analysis. If the rate of infiltration of water into the dried bonito is found, it is a very effective finding for setting the thickness of flakes of dried bonito and the extraction time to prepare buckwheat soup industrially. To obtain such knowledge, the time taken for the water to pass through flakes of dried bonito of various thicknesses, to vaporize and to remove latent heat till the temperature of the surfaces of flakes lowers was measured. The thickness of flakes of dried bonito and extraction time were set on the basis of the data thus obtained. Dired bonito was then supplied to a bench ...

1997-05-05

221

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the ...

2007-04-22

222

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, ...

2008-02-01

223

Development of the discrete-time adaptive sliding mode power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A newly developed discrete-time adaptive sliding mode power system stabilizer (PSS) is proposed in this paper. Because the proposed PSS is developed in the pure discrete-time domain it is able to maintain the stability with the rather slower smapling frequency compared to discretized conventional continuous-time sliding mode PSS. The proposed PSS has the three main superiorities to the conventional PSS. First, because the proposed PSS utilizes the sliding mode control method, it has the strong robustness to the variations of the system parameters. Hence, it can overcome the minor disturbances such as identification errors, modeling errors, etc. Second, the proposed PSS needs only input/output measurements as feedback signals. Hence, it does not need the measurements of the state variables as the conventional sliding mode PSS or PSS based on the linear quadratic control method does. ...

1996-12-31

224

Visualization of two-phase flow eddies in rectangular channels using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.

1994-12-31

225

Three-dimensional data processing for time resolved gamma-ray spectrometry  

International Nuclear Information System (INIS)

A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)

226

Solubility and rate of dissolution for Miscanthus in hydrophilic ionic liquids  

British Library Electronic Table of Contents (United Kingdom)

Miscanthus is a potential feedstock for the production of biofuels. Lignocellulosic biomass is not soluble in conventional solvents, but Miscanthus and other lignocellulosic biomass have reasonable solubilities in some ionic liquids. The solubility of Miscanthus in a variety of hydrophilic ionic liquids was measured as a function of particle size, temperature and time for dissolution. In addition to temperature and time, the ionic liquid anion has a significant effect on solubility and rate of dissolution. The moisture content of Miscanthus lowers its solubility in certain ionic liquids. Chloride, acetate, and phosphate-based ionic liquids favor solubility. A tentative correlation for the solubility of Miscanthus is proposed in terms of Abraham solvation parameters obtained from quantum-ch...

2011-01-01

227

Real-time neutron diffraction study of phase transitions in the Ti-D system after high pressure treatment  

International Nuclear Information System (INIS)

Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.

1992-09-01

228

Pre-waste-emplacement ground-water travel time sensitivity and uncertainty analyses for Yucca Mountain, Nevada; Yucca Mountain Site Characterization Project  

Energy Technology Data Exchange (ETDEWEB)

Yucca Mountain, Nevada is a potential site for a high-level radioactive-waste repository. Uncertainty and sensitivity analyses were performed to estimate critical factors in the performance of the site with respect to a criterion in terms of pre-waste-emplacement ground-water travel time. The degree of failure in the analytical model to meet the criterion is sensitive to the estimate of fracture porosity in the upper welded unit of the problem domain. Fracture porosity is derived from a number of more fundamental measurements including fracture frequency, fracture orientation, and the moisture-retention characteristic inferred for the fracture domain.

1993-01-01

229

Persistence of the N=28 shell closure far from stability  

Science.gov (United States)

The masses of 16 neutron-rich nuclei in the mass range from 35 to 45 have been measured using a direct time of flight technique following the fragmentation of a {sup 48}Ca beam at 60 MeV/nucleon. The masses of {sup 35,36}Mg, {sup 38}Al, {sup 39,40}Si, {sup 42,43}P and {sup 43,44}S are reported for the first time. Preliminary analysis shows that the N=28 shell closure persists, even if weakened by the large neutron excess.

1998-12-21

230

Persistence of the N=28 shell closure far from stability  

International Nuclear Information System (INIS)

The masses of 16 neutron-rich nuclei in the mass range from 35 to 45 have been measured using a direct time of flight technique following the fragmentation of a "4"8Ca beam at 60 MeV/nucleon. The masses of "3"5","3"6Mg, "3"8Al, "3"9","4"0Si, "4"2","4"3P and "4"3","4"4S are reported for the first time. Preliminary analysis shows that the N=28 shell closure persists, even if weakened by the large neutron excess.

1998-12-21

231

Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$  

CERN Document Server

The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.

2010-01-01

232

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

233

VLF wave stimulation by pulsed electron beams injected from the space shuttle  

International Nuclear Information System (INIS)

Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

234

Uptake of Pb by human skeleton and comparative metabolism of Pb and alkaline earth elements  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the retention of /sup 47/Ca and of /sup 203/Pb were made following their administration by intravenous injection. Translocation to bone was measured by ..gamma.. counting the feet of subjects. Uptake by bone of /sup 203/Pb was comparatively slow and extrapolation to the whole skeleton indicated that 20% of the dose has been taken up within 20 days. By time, a similar fraction of the dose has been excreted in urine. Uptake by bone of /sup 47/Ca was about 1.5-2 times the amount excreted in urine. Both the uptake by bone, and its excretion in urine, were more rapid than that of /sup 203/Pb due to the greater attachment of the latter to red blood cells. However, the plasma clearance rate for Pb, like that of Sr, was greater than that of Ca.

1984-12-01

235

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

236

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

237

Terahertz time-domain spectroscopy of atmospheric water vapor from 0.4 to 2.7 THz.  

Energy Technology Data Exchange (ETDEWEB)

We conducted broadband absorption measurements of atmospheric water vapor in the ground state, X {sup 1}A{sub 1} (000), from 0.4 to 2.7 THz with a pressure broadening-limited resolution of 6.2 GHz using pulsed, terahertz time-domain spectroscopy (THz-TDS). We measured a total of seventy-two absorption lines and forty-nine lines were identified as H{sub 2}{sup 16}O resonances. All the H{sub 2}{sup 16}O lines identified were confirmed by comparing their center frequencies to experimental values available in the literature.

2005-10-01

238

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

239

Study of oxygen diffusion in YBaCuO by isothermal internal friction. Etude par frottement interieur isotherme de la diffusion de l'oxygene dans YBaCuO  

Energy Technology Data Exchange (ETDEWEB)

The elastic behaviour of YBaCuO specimens has been studied by very low-frequency isothermal internal-friction measurements. A relaxation peak is observed which is attributed to oxygen atom jumps, between A(1/2 0 0) and B(0 1/2 0) sites, in the CuO planes of the orthorhombic phase. A limit relaxation time {tau}{sub 0}, 2.6 {center dot} 10{sup -15}s, and an activation energy, 1.3eV, have been obtained from the shift of the maximum damping frequency observed when the measurement temperature is changed. The proposed values for the limit relaxation time and the activation energy are in good agreement with those previously proposed in the literature.

1992-02-07

240

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

241

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

242

Mesodynamics in the SARS nucleocapsid measured by NMR field cycling  

Energy Technology Data Exchange (ETDEWEB)

Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultra-high field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R{sub 1} at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire {beta}-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.

2009-09-15

243

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

244

Influence of weather on the behaviour of outdoor-wintered beef cattle in Scandinavia  

British Library Electronic Table of Contents (United Kingdom)

The aim of the present investigation was to study the effect of weather and available protection on the behaviour of outdoor-wintered beef cattle (Bos taurus). A herd of 78-85 cattle head was studied during four winter months in the Southwest of Sweden. Protection was offered by coniferous forest situated on and around the 12ha pasture, which we divided into protection categories. During 240h we observed 10 cows and 10 heifers as focal animals (each 3h/month) during day time and adjusted observation times to the altitude of the sun. Close to the animals and at an unprotected spot of the pasture we measured temperature, wind speed and solar radiation and combined these variables to a single measure called Wind Chill Temperature (WCT). During observations the animals were in the forest in 12...

2011-01-01

245

Temporal measures and controls in ultrafast laser domain; Mesures et controles temporels dans le domaine des lasers ultrabrefs  

Energy Technology Data Exchange (ETDEWEB)

This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements ...

2004-12-15

246

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF ...

1996-12-31

247

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

248

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

249

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of ...

1998-06-01

250

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to ...

2000-03-21

251

Deep time travel  

Science.gov (United States)

Not Available

2008-09-01

252

Measurement of characteristics of an infrared free-electron laser with the L-band at Osaka University  

Energy Technology Data Exchange (ETDEWEB)

Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron beam from the linac is transported to a wiggler ...

1995-12-31

253

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron ...

1997-07-01

254

New constraints on the primordial black hole number density from Galactic gamma-ray astronomy  

CERN Document Server

Primordial black holes are unique probes of cosmology, general relativity, quantum gravity and non standard particle physics. They can be considered as the ultimate particle accelerator in their last (explosive) moments since they are supposed to reach, very briefly, the Planck temperature. Upper limits on the primordial black hole number density of mass $M_{\\star} = 5 10^{14}$ g, the Hawking mass (born in the big-bang terminating their life presently), is determined comparing their predicted cumulative $\\gamma$-ray emission, galaxy-wise, to the one observed by the EGRET satellite, once corrected for non thermal $\\gamma$-ray background emission induced by cosmic ray protons and electrons interacting with light and matter in the Milky Way. A model with free gas emissivities is used to map the Galaxy in the 100 MeV photon range, where the peak of the primordial black hole emission is expected. The best gas emissivities and additional model parameters are obtained ...

2009-01-01

255

Theory and method for selection of power system stabilizer location  

Energy Technology Data Exchange (ETDEWEB)

A new approach for the selection of best PSS locations in multimachine power systems is proposed in this paper. Study shows that the right-eigenvector measures the activity of state variables and the left-eigenvector measures the control effect of control signals. Based on the right and left eigenvector the concept of sensitivity of PSS effect (SPE) is presented and used to identify the best PSS locations. The proposed method is used to identify the best PSS location in a 13-machine system to increase the damping of an interarea mode. The time-domain simulation results confirm that the prediction of best PSS location by SPE method is correct and accurate.

1991-03-01

256

The ArgoNeuT LAr-TPC: A dedicated experiment for neutrino cross section measurement at FNAL  

British Library Electronic Table of Contents (United Kingdom)

ArgoNeuT, a Liquid Argon Time Projection Chamber (LAr-TPC), has recently collected thousands of neutrino and anti-neutrino events between 0.1 and 10 GeV in the NuMI beamline at Fermilab (FNAL). Among other issues, the experiment will measure the cross section of the neutrino and anti-neutrino Charged Current Quasi-Elastic (CCQE) interaction on Ar target and analyze the vertex activity associated with such events. Outcomes from the reconstruction of the events provide the main subject of this paper.

2011-01-01

257

Sulfuric acid/hydrogen peroxide rinsing study  

Energy Technology Data Exchange (ETDEWEB)

Sulfuric acid hydrogen peroxide mixtures (SPM) are commonly used in the semiconductor industry to remove organic contaminants from wafer surfaces. This viscous solution is very difficult to rinse off water surfaces. Various rinsing conditions were tested and the resulting residual acid left on the water surface was measured. Particle growth resulting from incomplete rinse is correlated with the amount of sulfur on the wafer surface measured by Time of Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). The amount of sulfur on the wafer structure after the rinse step is strongly affected by the wafer film type and contact angle prior to the SPM clean.

1995-12-01

258

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

259

Solution of the orthopositronium lifetime puzzle  

CERN Document Server

The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.

2004-01-01

260

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

261

Selective detection of hexachromium ions by localized surface plasmon resonance measurements using gold nanoparticles/chitosan composite interfaces.  

Science.gov (United States)

Selective removal of hexavalent chromium ions from aqueous solutions using a chitosan/gold nanoparticles composite film was demonstrated. Localized surface plasmon resonance (LSPR) was used to measure the interface stability and detect the incorporation of chromium ions over time. The effects of pH, ethylenediaminetetraacetic acid (EDTA), and various foreign ions such as trivalent chromium, sodium, calcium, phosphate, sulfate and chloride on the adsorption of hexavalent chromium were investigated. PMID:19381379

2009-03-04

262

Residual stress measurements on a stress relieved Zircaloy-4 weld by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

The macroscopic stress distribution across an annealed Zircaloy-4 gas tungsten arc weld was measured by neutron time-of-flight diffraction at the SMARTS diffractometer at Los Alamos National Laboratory. The stresses after annealing are about 40% lower than those in the same weld prior to heat treatment. The intergranular strains in the reference coupons, which give the macroscopic stress free lattice spacings, are consistent with the difference in cooling the strongly textured plate and the weakly textured weld.

2006-12-15

263

Physics with Polarized Antiprotons  

Energy Technology Data Exchange (ETDEWEB)

Polarized antiprotons produced by spin filtering with an internal polarized gas target provide access to a wealth of single- and double-spin observables, thereby opening a window to physics uniquely accessible with the HESR at FAIR. This includes a first measurement of the transversity distribution of the valence quarks in the proton, and a first measurement of the moduli and the relative phase of the time-like electric and magnetic form factors G{sub E,M} of the proton. In polarized and unpolarized pp-bar elastic scattering open questions like the contribution from the odd charge-symmetry Landshoff-mechanism at large |t| and spin-effects in the extraction of the forward scattering amplitude at low |t| can be addressed.

2006-04-15

264

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

265

Optimized Zn-electrode for the rechargeable zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

For the development of a long-lived electrically rechargeable zinc/air battery, the structure and wettability of pasted zinc electrodes were optimized. Pasted zinc electrodes, having the same nominal capacities but containing 1% to 10% cellulose, were prepared and tested under defined charge and discharge conditions in zinc-oxygen cells. The maximum power as well as the cycle life of these cells were measured. After different times of operation, the porosity and the pore size distribution of the pasted zinc electrodes were measured by means of mercury porosimetry. (author) 4 figs., 1 tab., 6 refs.

1996-06-01

266

Natural convection cooling of circumferentially finned transport casks  

International Nuclear Information System (INIS)

It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.

1983-12-01

267

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

268

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

269

Measurement of the K-shell ionization probability across a wide resonance: /sup 88/Sr(p,p/sub 0/) at 6. 06 MeV  

Energy Technology Data Exchange (ETDEWEB)

We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.

1982-09-01

270

Improved measurement of the branching ratio of J/psi-->K_S K_L  

CERN Document Server

The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.

2004-01-01

271

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

272

Hyperfine structure studies with the COMPLIS facility  

International Nuclear Information System (INIS)

COMPLIS is an experimental facility designed to carry out spectroscopic studies on radioisotopes produced by disintegration of elements available at CERN's Booster-ISOLDE on-line isotope separator. During recent series of experimental runs, hyperfine structure measurements have yielded information on nuclear moments and deformations of platinum and iridium isotopes. For the first time, population by #alpha#-decay from Hg was exploited to investigate "1"7"8"-"1"8"1Pt--the most neutron-deficient Pt isotopes yet studied. Successful measurements have recently been carried out on "1"8"2"-"1"8"9Ir.

1998-12-16

273

Fission neutron multiplicity for the /sup 242m/Am(n,f) reaction  

International Nuclear Information System (INIS)

This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeV electron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.

274

Expansion Rate Measurements at Moderate Pressure of Nonneutral Electron Plasmas in the Electron Diffusion Gauge (EDG) Experiment  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the expansion rate of pure-electron plasmas have been performed on the Electron Diffusion Gauge (EDG) device at background helium gas pressures in the 5 x 10(superscript -8) Torr to 1 x 10(superscript -5) Torr range, where plasma expansion due to electron-neutral collisions dominates over plasma expansion due to trap asymmetries. It is found that the expansion rate, defined as the time rate of change of the particles' mean-square radius, scales approximately linearly with pressure and inversely as the square of the magnetic field strength in this regime, in agreement with classical predictions.

2001-05-18

275

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

276

Determination of charge carrier mobility in poly(3hexylthiophene) with different current transient measurement techniques  

Energy Technology Data Exchange (ETDEWEB)

The carrier mobility in organic disordered materials, such as conjugated polymers, plays an important role in understanding the behaviour of organic electronic devices. We investigated the mobility of charge carriers in poly(3-hexylthiophene) (P3HT) using different current transient measurement methods. Besides the conventional transient photoconductivity experiment, time-of-flight (TOF), we used extraction current transient techniques, such as charge carrier extraction by linearly increasing voltage (CELIV), probing equilibrium carriers instead. The field and temperature dependence of the mobility are discussed in view of hopping transport in a Gaussian density of states distribution.

2007-07-01

277

Design of self-tuning PID power system stabilizer for multimachine power systems  

Energy Technology Data Exchange (ETDEWEB)

A self-tuning PID (proportional-integral-derivative) power system stabilizer (PSS) is presented for improving the dynamic stability of a multimachine power system over a wide range of operating conditions. In order to maintain good damping characteristic when there is a drastic change in system operating condition, the gain settings are adapted in real time based on the continuously measured system inputs and outputs. The proposed self-tuning stabilizer has a decentralized structure and only local measurements within each generating units are required for the adaptation process. The effectiveness of the proposed stabilizer is demonstrated by an example.

1988-08-01

278

Concentration of measures via size-biased couplings  

British Library Electronic Table of Contents (United Kingdom)

Let Y be a nonnegative random variable with mean?? and finite positive variance ? 2, and let Y s , defined on the same space as Y, have the Y size-biased distribution, characterized by Formula Not Shown Under a variety of conditions on Y and the coupling of Y and Y s , including combinations of boundedness and monotonicity, one sided concentration of measure inequalities such as Formula Not Shown hold for some explicit A and B. The theorem is applied to the number of bulbs switched on at the terminal time in the so called lightbulb process of Rao et?al. (Sankhy? 69:137?161, 2007).

2011-01-01

279

Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment  

International Nuclear Information System (INIS)

This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)

2006-10-21

280

Atmospheric carboxylic acids in southern California  

Energy Technology Data Exchange (ETDEWEB)

Intensive measurements of organic acids, inorganic acids, aldehydes and peroxyacetyl nitrate (PAN) in urban air were carried out at a Southern California smog receptor site, Glendora, CA, August 12-22, 1986. The objective of this project was to augment the data base regarding organic acids in urban air and to assess their role with emphasis on ambient levels, diurnal variations, phase distribution, emissions, in-situ formation and removal. The relative abundance of organic acids and inorganic acids was determined for the first time from simultaneous measurements carried out during this study.

1988-09-01

281

Absolute, cascade-free cross sections for the "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Absolute, cascade-free excitation cross sections in an ion have been measured for the resonance "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged electron-ion beams methods. Measurements were carried out at electron energies of below threshold to 6 times threshold. Comparisons are made with 2-, 5-, and 15-state close-coupling and distorted-wave theories. There is good agreement between experiment and the 15-state close-coupling cross sections over the energy range of the calculations.

282

A review of the probabilistic aspects of localized corrosion  

Energy Technology Data Exchange (ETDEWEB)

Localized corrosion has a stochastic character by nature. This character leads to an observed random behavior: fluctuations of the free potential, fluctuations of the current when a constant potential is maintained. This random signal, which is similar to an electric noise, can be analyzed either in the time domain by counting the events or in the frequency domain by measuring the power spectral density of the electrochemical noise. The experimental techniques developed for investigating the localized corrosion on the probabilistic point of view, i.e., statistical counting and power spectral density measurements, are discussed. Then the experimental results reported in the literature are reviewed in order to see what kind of parameters are accessible and how they can be related to the localized corrosion processes.

1990-04-01

283

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

284

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

285

A Year of Radiation Measurements at the North Slope of Alaska Second Quarter 2009 ARM and Climate Change Prediction Program Metric Report  

Energy Technology Data Exchange (ETDEWEB)

In 2009, the Atmospheric Radiation Measurement (ARM) Program and the Climate Change Prediction Program (CCPP) have been asked to produce joint science metrics. For CCPP, the second quarter metrics are reported in Evaluation of Simulated Precipitation in CCSM3: Annual Cycle Performance Metrics at Watershed Scales. For ARM, the metrics will produce and make available new continuous time series of radiative fluxes based on one year of observations from Barrow, Alaska, during the International Polar Year and report on comparisons of observations with baseline simulations of the Community Climate System Model (CCSM).

2009-04-15

286

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...

287

The relationship between income and environment in Turkey: Is there an environmental Kuznets curve?  

British Library Electronic Table of Contents (United Kingdom)

In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO2 emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM10 and SO2 measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO2 and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationshi...

2009-01-01

288

The envelope order spectrum based on generalized demodulation time-frequency analysis and its application to gear fault diagnosis  

British Library Electronic Table of Contents (United Kingdom)

The generalized demodulation time-frequency analysis is a novel signal processing method, which is particularly suitable for the processing of multi-component amplitude-modulated and frequency-modulated (AM-FM) signals as it can decompose a multi-component signal into a set of single-component signals whose instantaneous frequencies own physical meaning. While fault occurs in gear, the vibration signals measured from gearbox would exactly display AM-FM characteristics. Therefore, targeting the modulation feature of gear vibration signal in run-ups and run-downs, a fault diagnosis method in which generalized demodulation time-frequency analysis and envelope order spectrum technique are combined is put forward and applied to the transient analysis of gear vibration signal. Firstly the multi-...

2010-01-01

289

The Benchmark Test Results of QNX RTOS  

International Nuclear Information System (INIS)

A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

2010-10-01

290

Solution state hybridization detection using time-resolved fluorescence anisotropy of quantum dot-DNA bioconjugates  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we demonstrate the application of time-resolved fluorescence anisotropy measurements to detect solution state hybridization of streptavidin conjugate (CdSe)ZnS quantum dots (QD). The study was performed on samples containing 10nM QD incubated with 800nM DNA. We show that the rotational correlation time of QD-DNA constructs increases significantly upon hybridization with values of 330ns (QD-ssDNA) and 1.3ms (QD-dsDNA), corresponding to a diameter of 14nm and 23nm respectively. The present study opens a new modality for hybridization detection using quantum dots.

2010-01-01

291

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.

1984-10-01

292

Recent results from BESIII  

CERN Document Server

Using about $226\\times 10^6$ $\\jpsi$ events and $106\\times 10^6$ $\\psi^{\\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\\etap \\to \\eta \\pi^+ \\pi^-$ decay is studied, the direct measurement of $a^{0}_{0}(980)-f_{0}(980)$ mixing is performed, $X(2120)$ and $X(2370)$ are observed in the $\\pi^+\\pi^-\\eta^\\prime$ invariant mass spectrum, $\\psi^{\\prime}\\to\\gamma\\pi^0$ and $\\psi^{\\prime}\\to\\gamma\\eta$ are observed for the first time, and the decays $\\chi_{cJ}\\to\\gamma V$ ($V=\\phi$, $\\rho^0$, $\\omega$) are studied.

2010-01-01

293

Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study  

British Library Electronic Table of Contents (United Kingdom)

Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time.A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate f...

2007-01-01

294

Predictability, complexity and learning  

CERN Document Server

We define {\\em predictive information} $I_{\\rm pred} (T)$ as the mutual information between the past and the future of a time series. Three qualitatively different behaviors are found in the limit of large observation times $T$: $I_{\\rm pred} (T)$ can remain finite, grow logarithmically, or grow as a fractional power law. If the time series allows us to learn a model with a finite number of parameters, then $I_{\\rm pred} (T)$ grows logarithmically with a coefficient that counts the dimensionality of the model space. While logarithmic growth of related information theoretic quantities has been found in previous work on learning, power law growth has not been seen in this context. We find that it is associated, for example, with the learning of infinite parameter (or nonparametric) models such as continuous functions with smoothness constraints. There are connections between the predictive information and ...

2000-01-01

295

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production ...

1981-10-01

296

High-vacuum time-resolved laser-induced incandescence of?flame-generated soot  

British Library Electronic Table of Contents (United Kingdom)

We have measured time-resolved laser-induced incandescence of flame-generated soot under high-vacuum conditions (4.1?10?6 mbar) at an excitation wavelength of 532 nm with laser fluences spanning 0.06?0.5 J/cm2. We generated soot in an ethylene/air diffusion flame, introduced it into the vacuum system with an aerodynamic lens, heated it using a pulsed laser with a spatially homogeneous and temporally smooth laser profile, and recorded LII temporal profiles at 685 nm. At low laser fluences LII signal decay rates are slow, and LII signals persist beyond the residence time of the soot particles in the detection region. At these fluences, the temporal maximum of the LII signal increases nearly linearly with increasing laser fluence until reaching a plateau at ?0.18?J/cm2. At higher fluences, th...

2011-01-01

297

Fast PIN-diode beam loss monitors at Tevatron  

Energy Technology Data Exchange (ETDEWEB)

The article is devoted to results of fine time structure of particle losses in Tevatron with use of fast beam loss monitors (BLM) based on PIN-diodes. An ultimate goal of the new BLMs is to distinguish losses of protons and antiprotons from neighbor bunches with 132 ns bunch spacing in the Tevatron collider upgrade. The devices studied fit well to the goal as they can recognize even seven times closer - 18.9 ns - spaced bunches` losses in the Tevatron fixed target operation regime. We have measured main characteristics of the BLM as well as studied the proton losses over 10 decades of time scale - from dozen of minutes to dozen of nanoseconds. Power spectral density of the losses is compared with spectra of the proton beam motion.

1997-07-01

298

Exact Simulation of Bessel Diffusions  

CERN Document Server

We consider the exact path sampling of the squared Bessel process and some other continuous-time Markov processes, such as the CIR model, constant elasticity of variance diffusion model, and hypergeometric diffusions, which can all be obtained from a squared Bessel process by using a change of variable, time and scale transformation, and/or change of measure. All these diffusions are broadly used in mathematical finance for modelling asset prices, market indices, and interest rates. We show how the probability distributions of a squared Bessel bridge and a squared Bessel process with or without absorption at zero are reduced to randomized gamma distributions. Moreover, for absorbing stochastic processes, we develop a new bridge sampling technique based on conditioning on the first hitting time at zero. Such an approach allows us to simplify simulation schemes. New methods are illustrated with pricing ...

2009-01-01

299

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration ...

1994-08-01

300

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration ...

1994-01-01

301

Determining a bisection bandwidth for a multi-node data communications network  

Energy Technology Data Exchange (ETDEWEB)

Methods, systems, and products are disclosed for determining a bisection bandwidth for a multi-node data communications network that include: partitioning nodes in the network into a first sub-network and a second sub-network in dependence upon a topology of the network; sending, by each node in the first sub-network to a destination node in the second sub-network, a first message having a predetermined message size; receiving, by each node in the first sub-network from a source node in the second sub-network, a second message; measuring, by each node in the first sub-network, the elapsed communications time between the sending of the first message and the receiving of the second message; selecting the longest elapsed communications time; and calculating the bisection bandwidth for the network in dependence upon the number of the nodes in the first sub-network, the predetermined message size of the first test message, and ...

2010-01-26

302

A real-time neutron radiography diagnostic of a vertical co-current two-phase flow channel with a hexagonal finned bundle  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.

2003-06-01

303

[Fast neutron cross section measurements]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution ...

1991-12-31

304

Supersymmetry Breaking Scalar Masses and Trilinear Soft Terms From High-Dimensional Operators in E_6 SUSY GUT  

CERN Document Server

In the GmSUGRA scenario with the high-dimensional operators containing the GUT Higgs fields, we systematically studied the supersymmetry breaking scalar masses, SM fermion Yukawa coupling terms, and trilinear soft terms in the E_6 SUSY GUT model where the gauge symmetry is broken down to the SO(10)\\tm U(1) gauge symmetry, SU(3)_C\\times SU(3)_L \\times SU(3)_R gauge symmetry, SU(6)\\times SU(2)_a (a={\\rm L,R,X}) gauge symmetry, flipped SU(5) gauge symmetry etc. In addition, we considered the scalar and gaugino mass relations, which can be preserved from the GUT scale to the electroweak scale under one-loop RGE running, in the SU(3)_C\\times SU(3)_L \\times SU(3)_R model arising from the E_6 model. With such relations, we may distinguish the mSUGRA and GmSUGRA scenarios if we can measure the supersymmetric particle spectrum at the LHC and ILC.

2011-01-01

305

Management and optimization of the CPCU network working  

Energy Technology Data Exchange (ETDEWEB)

The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing ...

1991-10-01

306

Higher order time-frequency analysis as a tool for health monitoring  

Energy Technology Data Exchange (ETDEWEB)

In machine condition monitoring many fault-related vibration signals are highly non-stationary. Time-frequency representations comprise the natural signal-processing tool traditionally used for representing such non-stationary signals. The methods used in this analysis are based on the second order statistics of a signal. This paper discusses the use of higher order time frequency methods in the context of a condition monitoring application. The paper outlines the two classes of higher order representations: the L-Wigner distribution and the sliced Wigner higher order distribution. The use of higher order distributions introduces the possibility of non-oscillating cross-terms, a problem not encountered in conventional bilinear time-frequency methods. Techniques for reducing these cross-terms are presented. The paper compares the performance of bilinear and higher order time-frequency methods using ...

2003-07-01

307

Quantifying the Reactive Uptake of OH by Organic Aerosols in aContinuous Flow Stirred Tank Reactor  

Energy Technology Data Exchange (ETDEWEB)

Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried ...

2009-03-01

308

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type ...

1995-07-01

309

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel ...

1346-01-01

310

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

311

Very high resolution measurements of the total cross section of natural iron  

Energy Technology Data Exchange (ETDEWEB)

The total cross section of natural Fe has been measured with the GELINA pulsed white neutron source with a time-of-flight resolution of about 3.8 ps/m and good statistical precision. Measurements have been performed on three sample thicknesses including one with an average transmission of 0.1, in order to check for consistency and for remaining resolution effects. The cross sections in the {open_quotes}unresolved resonance region{close_quotes} still show rather strong fluctuations. These data will directly be used in shielding benchmark calculations. The resonance region data will be analysed by an R-matrix routine and the parameters be compared to existing compilations.

1994-12-31

312

Secure Direct Communication Based on Non-Orthogonal Entangled Pairs and Local Measurement  

Science.gov (United States)

We propose a quantum secure direct communication scheme based on non-orthogonal entangled pairs and local measurement. In this scheme, we use eight non-orthogonal entangled pairs to act as quantum channels. Due to the non-orthogonality of the quantum channels, the present protocol can availably prohibit from all kinds of valid eavesdropping and acquire a secure quantum channel. By local measurement, the sender acquires a secret random sequence. The process of encoding on the random sequence is identical to the one in one-time-pad. So the present protocol is secure. Even for a highly lossy channel, our scheme is also valid. The scheme is feasible with present-day techniques.

2008-12-01

313

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

314

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

315

Searching for the Neutrino Mixing Angle Theta-13 at Reactors  

CERN Document Server

Two neutrino mixing angles have been measured, and much of the neutrino community is turning its attention to the unmeasured mixing angle, $\\quq$, whose best limit comes from the reactor neutrino experiment CHOOZ.\\cite{bib:chooz} New two detector reactor neutrino experiments are being planned, along with more ambitious accelerator experiments, to measure or further limit $\\quq$. Here I will overview how to measure $\\quq$ using reactor neutrinos, mention some experiments that were considered and are not going forward, and review the current status of four projects: Double Chooz in France, Daya Bay in China, RENO in South Korea and Angra in Brazil. Finally I will mention how the neutrino observer can gauge progress in these projects two years from now as we approach the times corresponding to early estimates for new results.

2007-01-01

316

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

317

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...

318

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

319

Measuring perceptual centers using the phase correction response  

British Library Electronic Table of Contents (United Kingdom)

The perceptual center (P-center) is fundamental to the timing of heterogeneous event sequences, including music and speech. Unfortunately, there is currently no comprehensive and reliable model of P-centers in acoustic events, so P-centers must instead be measured empirically. This study reviews existing measurement methods and evaluates two methods in detail?the rhythm adjustment method and a new method based on the phase correction response (PCR) in a synchronous tapping task. The two methods yielded consistent P-center estimates and showed no evidence of P-center context dependence. The PCR method appears promising because it is accurate and efficient and does not require explicit perceptual judgments. As a secondary result, the magnitude of the PCR is shown to vary systematically with ...

2011-01-01

320

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse annealing results and ...

1995-06-01

321

IC chip stress during plastic package molding  

Energy Technology Data Exchange (ETDEWEB)

Approximately 95% of the world`s integrated chips are packaged using a hot, high pressure transfer molding process. The stress created by the flow of silica powder loaded epoxy can displace the fine bonding wires and can even distort the metalization patterns under the protective chip passivation layer. In this study the authors developed a technique to measure the mechanical stress over the surface of an integrated circuit during the molding process. A CMOS test chip with 25 diffused resistor stress sensors was applied to a commercial lead frame. Both compression and shear stresses were measured at all 25 locations on the surface of the chip every 50 milliseconds during molding. These measurements have a fine time and stress resolution which should allow comparison with computer simulation of the molding process, thus allowing optimization of both the manufacturing process and mold geometry.

1998-02-01

322

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

323

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

324

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

325

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

326

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

327

On the theory of transient enhanced diffusion in boron-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

1991-01-01

328

On the theory of transient enhanced diffusion in boron-implanted silicon  

International Nuclear Information System (INIS)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

329

Nuclear magnetic resonance and the question of 5f electron localization in the actinides  

International Nuclear Information System (INIS)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).

330

Nuclear magnetic resonance and the question of 5F electron localization in the actinides  

Science.gov (United States)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.

1976-01-01

331

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

332

NAME=\\  

Wastenet

... This is true because a shorter residence time means that ground water moves 'faster.' Thus, contamination will get to the drinking well from the recharge area (point of entry) faster if the ground water is younger. However, it has been difficult to measure the exact age of young ground water. The conventional indicator has been tritium, a radioactive form of hydrogen, but its ...

333

Microwave Oven for the Rapid Determination of Total Solids Content of Natural Rubber Latex  

British Library Electronic Table of Contents (United Kingdom)

The suitability of using the microwave oven for the rapid determination of total solids content (TSC) of natural rubber latex has been established over a broad range of dry rubber content (DRC). The total solids content values obtained by the microwave oven method are compared with the values obtained by heating in a conventional convection oven. Heating in a microwave oven is advantageous as the measurement time could be reduced considerably.

2008-01-01

334

Major steam turbine losses. Causes, repair measures, recommissioning; Grossschaeden an Dampfturbosaetzen. Ursachen, Reparaturen, Weiterbetrieb  

Energy Technology Data Exchange (ETDEWEB)

Substantial damages at main components of steam turbines do not have to result inevitably in an exchange of the components concerned. Rather a preliminary or final repair is possible which also considers the cause of the damage. An important condition with the technically complex questions is an appropriate qualification and experience of all involved persons. The common task of operators, manufacturers and insurance companies is to preserve the balance from costs, expenditure of time and risk.

2010-07-01

335

Investigation of radiation defects in solids using the EXAFS method  

International Nuclear Information System (INIS)

The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.

1978-02-15

336

High power model fabrication of disk-and -washer cavity  

International Nuclear Information System (INIS)

The high-power model of Disk-and Washer (DAW) cavity for electron acceleration is under fabrication. Basic Dimensions of the cavity were determined from aluminum model measurement and electromagnetic field calculation. We have fabricated model made of OFC (Oxygen Free Copper) five times in total. Some details are optimized and corrected, and then the final brazing are proceeding. These model results and present status are described. (author)

2000-07-12

337

Formation of streamers in nitrogen and dry air; Vorming van streamers in stikstof en lucht  

Energy Technology Data Exchange (ETDEWEB)

The results of a time-resolved study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen and dry air. Results of experiments and two-dimensional simulations are presented. It is shown what processes are responsible for the formation of a streamer. The trends of externally measured quantities correspond with those predicted by our model. 3 figs., 5 refs.

1997-01-01

338

Features of laser damage to elastic polymers  

Energy Technology Data Exchange (ETDEWEB)

Threshold pump intensity values leading to irreversible damage to colored laser elements based on elastic polymers were measured. The damage to colored elastomers is connected with absorbing microinclusions but is independent of molecular absorption. It is shown that damage to the elastomers has a pronounced threshold character in contrast to the microdamage accumulation effect in glassy polymers. The damage threshold for elastomers is 1.5 times higher, which is connected with the absence of microstresses (characteristics for organic glasses) in the specimens. 13 references.

1988-03-01

339

Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup  

CERN Document Server

The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).

2010-01-01

340

Emittance of investment casting molds  

Energy Technology Data Exchange (ETDEWEB)

This document describes measurements of the directional spectral emittance of four ceramic mold materials. The work was performed with the samples at {approximately} 900{degree}C in a vacuum vessel pumped to {approximately}3 {times} 10{sup {minus}6}Torr. Results conform to expectations derived from prior work done with similar samples.

1994-07-15

341

Electric loading of power transmission lines - statistical methodology and real time management; Carregamento eletrico de linhas de transmissao - metodologia estatistica e gerenciamento em tempo real  

Energy Technology Data Exchange (ETDEWEB)

This paper shows a computerized system, that adopt a statistical methodology and simultaneous measurements of wind velocity and environment temperature, as an experiences at the power transmission lines with environmental monitoring systems. 9 figs., 16 refs.

1991-12-31

342

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

343

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

344

A non-invasive approach for the determination of rumen pH  

Environmental Research Database

DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...

2004-01-31

345

A comparison of methods for calculating audible noise of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.

1982-10-01

346

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography ...

1986-01-01

347

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous ...

1986-01-01

348

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron ...

349

Transient radon diffusion through radon-proof membranes: A new technique for more precise determination of the radon diffusion coefficient  

Energy Technology Data Exchange (ETDEWEB)

The following paper is focused on the numerical modelling of the transient radon diffusion through radon-proof membranes during the measurement of their radon diffusion coefficient. The major aim of such numerical modelling is to increase the accuracy of radon diffusion coefficients derived from the measured data sets. The developed complex ''transient'' numerical model is able to calculate the radon diffusion coefficient with sufficient accuracy from almost any data set - even from a short-time measurement with a non-linear course of results. This numerical model can also be used for various analyses of transient radon transfer processes (e.g. for the calculation of radon distribution curves within the membrane). The following paper presents governing equations for the simulation model, together with a brief description of algorithms incorporated in the newly ...

2009-06-15

350

Synchronous Averaging for Asynchronous Sampling Data  

Science.gov (United States)

The progress of digital audio technology enabled the familiar use of the products such as CD and DAT in the acoustic measurement. For example, a signal reproduced with CD player is inputted into a subject of measurement and DAT recorder records its response. However, the sampling cannot be synchronized completely with the input signal although both nominal sample rates are set up equally, because player and recorder work independently. It is the most popular software solution to perform the synchronous addition after converting the recorded signal into the original sampling rate. However, the rate conversion also has the error due to the windowing in the high frequency region of processed signal. This paper proposes a new method for averaging asynchronous sampling data to solve these problems. To evaluate performance, the transfer function of only measuring equipment estimated from asynchronous sampling data was compared ...

2005-01-01

351

Life Under Your Feet: An End-to-End Soil Ecology Sensor Network, Database, Web Server, and Analysis Service  

CERN Document Server

Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented ...

2007-01-01

352

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and ...

2005-01-01

353

The Orbit of the Eclipsing X-ray Pulsar EXO 1722-363  

CERN Document Server

With recent and archival Rossi X-Ray Timing Explorer (RXTE) X-ray measurements of the heavily obscured X-ray pulsar EXO 1722-363 (IGR J17252-3616), we carried out a pulse timing analysis to determine the orbital solution for the first time. The binary system is characterized by a_x sin(i) = 101 +/- 3 lt-s and P_orb = 9.7403 +/- 0.0004 days (90% confidence), with the precision of the orbital period being obtained by connecting datasets separated by more than 7 years (272 orbital cycles). The orbit is consistent with circular, and e 61 degrees at the 99% confidence level, the radius of the primary is between 21 R_sun and 37 R_sun, and its mass is less than about 22 M_sun. The acceptable range of radius and mass shows that the primary is probably a supergiant of spectral type B0I-B5I. Photometric measurements of its likely counterpart are consistent with the spectral type and ...

2006-01-01

354

Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen  

Science.gov (United States)

Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid ...

2010-01-01

355

Port pollution and exhaust emissions from ships  

Energy Technology Data Exchange (ETDEWEB)

This presentation gives the results of a research programme aimed at evaluating exhaust emissions from ships moving within confined coastal zones, as in Piraeus harbour. The level of various exhaust emissions were estimated on the basis of a mathematical model applied for each sea traffic element (ship). Hourly and daily records of all ships` movements in different parts of the harbour were compiled, covering extended periods of time and associated with different shipping operational characteristics (peaks, lows, etc). In order to correlate the exhaust emissions from shipping with the quality of the air in the area of interest, land-based measurements for the same pollutants were carried out in selected locations, near the port and in the greater Athens area. This enabled the investigation of time and spatial diffusion of exhaust emissions from shipping within the area of interest, taking into account the influence of ...

1995-12-31

356

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated ...

2001-04-01

357

Measurement of the branching fractions for $J/\\psi\\to\\gamma\\pi^0$, $\\gamma\\eta$ and $\\gamma\\eta^{\\prime}$  

CERN Document Server

The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.

2006-01-01

358

Effects of comonomer and two-step oxidation on production of polyacrylonitrile-based carbon fibers. Polyacrylonitrile kei tanso sen'i no seizo ni okeru sanka jikan ni oyobosu zenkutai sen'i no kyojugo seibun oyobi dankai sanka no koka  

Energy Technology Data Exchange (ETDEWEB)

The oxidation conditions were investigated for obtaining a higher productivity in the production of high strength carbon fiber from polyacrylonitrile (PAN). The effect of incorporation of 2 % comonomer such as methyl acrylate (MA), acrylate containing carboxylate (SA), acrylamide (AAm), and hydroxyethyl acrylate (HEA) on the oxidation conditions was also investigated. The measurement of DSC and bonded oxygen content revealed that the most effective comonomer for promoting the cyclization of nitril group and the bonding of oxygen was found to be SA, and the second best was AAm. The measurement of tensile strength of carbon fiber showed that the copolymer of SA, HEA, and MA gave a high strength fiber. It took a long time to oxidize the carbon fiber when it was oxidized at a temperature on which double layer structure was not formed. To shorten the production time, a method of combining the upper limit ...

1994-06-10

359

Effects of carbon monoxide on myocardial ischemia  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to determine whether low doses of carbon monoxide (CO) exacerbate myocardial ischemia during a progressive exercise test. The effect of CO exposure was evaluated using the objective measure of time to development of electrocardiographic changes indicative of ischemia and the subjective measure of time to onset of angina. Sixty-three male subjects (41-75 years) with well-documented coronary artery disease, who had exertional angina pectoris and ischemic ST-segment changes in their electrocardiograms, were studied. Results from three randomized, double-blind test visits (room air, low and high CO) were compared. The effect of CO exposure was determined from the percent difference in the end points obtained on exercise tests performed before and after a 1-hr exposure to room air or CO. A significant dose-response relationship was found for the individual differences in the ...

1991-02-01

360

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...

2003-12-01

361

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...

2003-12-01

362

Visualization and measurement of heat transfer phenomenon  

Energy Technology Data Exchange (ETDEWEB)

This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...

1995-03-01

363

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the ...

2000-05-01

364

Statistical measure of association between smoking and lung cancer in Abakaliki, Ebonyi State Nigeria.  

Science.gov (United States)

The hazards of smoking in relation to lung cancer can never be over emphasized. In recent times shortly after Ebonyi State was created in 1996, the capital territory has increasingly been polluted by either quarry operators, motorcycle (Okada) riders or reckless cigarette smokers and bush burning. To investigate the havoc caused by all these on people, questionnaire was distributed among smokers and non smokers in various areas of specialization and habitations. In measuring the significance of association and the degree of association, a chi2 test and odds ratio method of analysis was employed. The result of the analysis showed that non-smokers do suffer lung cancer. It also revealed that the chances of a smoker to have lung cancer is 1.765 times higher than that of a non-smoker. Analysis also showed that lung cancer depends on age of smokers. It was later discovered that middle aged population are mostly affected, by the ...

2009-04-01

365

Simultaneous quantitative measurement of biodegradability and toxicity of environmental chemicals  

International Nuclear Information System (INIS)

Investigations were made on the biodegradability and bacterial toxicity of chemicals. The intention was to obtain data necessary for estimating and judging the behaviour of these chemicals during aerobic biological waste water treatment. The course of biodegradation and toxicity with time and concentration could be measured, quantified and described. As test procedure, the respirometric dilution method was used. This method is based on a die away test with continuous measuring of the oxygen used for biochemical oxidation processes. The course of the oxygen demand with time and concentration shows the biodegradation and toxicity patterns of the tested chemical. A variety of household and industrial chemicals were investigated. One group of substances were microbiocides, some of which showed toxic effects at concentrations less than 20 mg/l while others were biodegradable even at concentrations of 200 ...

1994-04-01

366

Photoconducting properties of ultraviolet detectors based on GaN and Al{sub 1{minus}x}Ga{sub x}N films grown by ECR-MBE  

Energy Technology Data Exchange (ETDEWEB)

GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection ...

1997-12-31

367

Photoconducting properties of ultraviolet detectors based on GaN and Al_1_-_xGa_xN films grown by ECR-MBE  

International Nuclear Information System (INIS)

GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1996-12-02

368

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

369

Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum  

Energy Technology Data Exchange (ETDEWEB)

For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the ...

1996-10-01

370

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the ...

1997-04-01

371

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed ...

372

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed ...

2007-03-15

373

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable ...

1980-01-01

374

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, ...

2011-09-01

375

The relationship between income and environment in Turkey: Is there an environmental Kuznets curve?  

Energy Technology Data Exchange (ETDEWEB)

In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO{sub 2} emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM{sub 10} and SO{sub 2} measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO{sub 2} and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO{sub 2} and PM{sub 10} emissions. Therefore, the results of our ...

2009-03-15

376

The relationship between income and environment in Turkey: Is there an environmental Kuznets curve?  

International Nuclear Information System (INIS)

In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO2 emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM10 and SO2 measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO2 and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO2 and PM10 emissions. Therefore, the results of our time series and panel data analyses ...

2009-03-01

377

The relationship between income and environment in Turkey. Is there an environmental Kuznets curve?  

Energy Technology Data Exchange (ETDEWEB)

In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO{sub 2} emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM{sub 10} and SO{sub 2} measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO{sub 2} and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO{sub 2} and PM{sub 10} emissions. Therefore, the results of our ...

2009-03-15

378

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results ...

1997-02-01

379

Surface treatment of Ti-6Al-4V alloy by rf plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

The Ti-6Al-4V alloy was treated by inductively coupled rf plasma nitriding. The effects of plasma-processing time in the range of 5-35 min on the microstructure and the mechanical properties of the plasma-nitrided Ti-6Al-4V samples were studied. The plasma power input was adjusted at 450 W and pure N{sub 2} gas was introduced to establish a treatment pressure of 8.0-8.4 x 10{sup -2} mbar. The characteristics of the nitrided layers have been investigated by microhardness testing, surface roughness measurements, optical microscopy, and x-ray diffraction. The results show that the surface microhardness increases as the plasma-processing time increases to reach 2000 HV0.1 at a plasma-processing time of 35 min. A high nitriding rate of 2.81 {mu}m{sup 2} s{sup -1} at a plasma-processing time of 25 min was achieved. The formation of the hard phases TiN, Ti{sub 2}N, and Ti(N) in the ...

2007-10-03

380

Surface treatment of Ti-6Al-4V alloy by rf plasma nitriding  

International Nuclear Information System (INIS)

The Ti-6Al-4V alloy was treated by inductively coupled rf plasma nitriding. The effects of plasma-processing time in the range of 5-35 min on the microstructure and the mechanical properties of the plasma-nitrided Ti-6Al-4V samples were studied. The plasma power input was adjusted at 450 W and pure N_2 gas was introduced to establish a treatment pressure of 8.0-8.4 x 10"-"2 mbar. The characteristics of the nitrided layers have been investigated by microhardness testing, surface roughness measurements, optical microscopy, and x-ray diffraction. The results show that the surface microhardness increases as the plasma-processing time increases to reach 2000 HV0.1 at a plasma-processing time of 35 min. A high nitriding rate of 2.81 #mu#m"2 s"-"1 at a plasma-processing time of 25 min was achieved. The formation of the hard phases TiN, Ti_2N, and Ti(N) in the Ti-6Al-4V surfaces are found ...

2007-10-03

381

Minority-carrier lifetime damage coefficient of irradiated InP  

Energy Technology Data Exchange (ETDEWEB)

Minority-carrier lifetime damage coefficients for 1 MeV electron, 3 MeV proton, and 6 MeV alpha particle irradiation of n-type (4.5{times}10{sup 15} and 1.3{times}10{sup 17}cm{sup {minus}3}) and p-type (2.5{times}10{sup 17}cm{sup {minus}3}) InP have been measured using time-resolved photoluminescence. These values are relatively insensitive to carrier type and show a slight increase with increasing carrier concentration. Evidence of comparable electron and hole capture lifetimes is found for the dominant recombination defect. The effect of 3 MeV proton and 6 MeV alpha particles relative to 1 MeV electrons is an increase in the lifetime damage coefficient by factors of about 10{sup 4} and 10{sup 5}, respectively. {copyright} {ital 1997 American Institute of Physics.}

1997-09-01

382

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a ...

1982-04-01

383

Measurement of the {beta}-{nu} angular correlation parameter in the decay of {sup 6}He using a Paul trap; Mesure du coefficient de correlation angulaire {beta}-{nu} dans la decroissance de {sup 6}He a l'aide d'un piege de Paul  

Energy Technology Data Exchange (ETDEWEB)

The central topic of this work is the study of the properties and the implementation of a Paul trap used for the measurement of the beta-neutrino angular correlation parameter in the decay of {sup 6}He. This coefficient provides a signature of the nature of the interactions involved in the weak interaction. The value of this coefficient can be deduced from the kinematical distribution of the decay events. An electromagnetic trap is used for the trapping of {sup 6}He{sup +} ions in a small volume. This trap has an open geometry that enables the detection in coincidence of the electron and the recoil ion emitted in the beta decay. A dedicated detection set up is used for the measurement of the electron energy, the ion time of flight and the position of the two particles for each event. A general description of the LPCTrap facility and of its performances is presented and shows that this set up is able to fulfill the proposed ...

2007-07-15

384

What are the odds of time travel?  

CERN Multimedia

What are the odds of time travel?

2009-01-01

385

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 {ell}/s (1 ft{sup 3}/min). The water flow rate was varied between 0 and 3.78 {ell}/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6} n/cm{sup 2}{center_dot}s{sup {minus}1} directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum ...

1995-09-01

386

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6}n/cm{sup 2}/s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image ...

1992-12-31

387

Void fraction measurements using neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 ell/s (1 ft"3/min). The water flow rate was varied between 0 and 3.78 ell/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10"6 n/cm"2#centre dot#s"-"1 directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on both ...

1995-01-01

388

Reliability of indices of neuromuscular leg performance in end-stage renal failure.  

Science.gov (United States)

The purpose of this study was to examine the day-to-day reproducibility and single measurement reliability of peak force, time to half peak force and rate of force development indices of knee extension neuromuscular performance in patients with end-stage renal failure. Eleven self-selected patients (6 men, 5 women) receiving maintenance dialysis (dialysis history 67 +/- 42.8 month) completed 3 inter-day assessment sessions. Each comprised a standardized warm-up and 3 intermittent static maximal voluntary actions of the knee extensors of the preferred limb (45 degrees knee flexion angle [0 degrees = full knee extension]) using a specially-constructed dynamometer. Repeated measures ANOVA of coefficient of variation scores revealed significant differences between indices in their reproducibility across day-to-day trials. Post-hoc comparisons of group mean scores suggested that peak force (6.6 +/- 3.0%) offers significantly ...

2002-11-01

389

High resolution seismic refraction method with multichannel digital data acquisition system; Digital ta channel sokutei system wo mochiita koseido kussetsuho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a multichannel digital data acquisition system and examples of measurements with the system in seismic exploration using the high resolution seismic refraction method. The high resolution seismic refraction system performs analyses nearly automatically by using a computer after initial travel time has been read. Therefore, the system requires high-accuracy travel time data, for which a multichannel digital measuring instrument developed recently for seismic exploration using the refraction method has been used for the measurement. The specification specifies the number of channels at 144 as a maximum, a sampling time of 62.5 {mu}sec to 4 m sec, the maximum number of sampling of 80,000 samples, and gain accuracy of {plus_minus} 1%. The system was used for surveying a tunnel having a maximum soil cover of about 800 m. The traverse line length ...

1997-05-27

390

Heavy metals in earthworms of Baden-Wuerttemberg. Part 1. Metal contents in earthworms from long-term forest observation plots; Schwermetalle in Regenwuermern Baden-Wuerttembergs. Teil 1. Metallgehalte in Regenwuermern von Wald-Dauerbeobachtungsflaechen  

Energy Technology Data Exchange (ETDEWEB)

Since 1984 the Environmental Protection Agency (LfU) of the State of Baden-Wuerttemberg has been investigating the heavy metal burden of earthworms from representative long-term forest observation plots. These investigations are aimed at elucidating and assessing adverse effects of pollutants on the soil biocenosis. Methods: At first only lead and cadmium were measured in the worms; in repetitive measurements over the years further metals or metalloid elements such as aluminum, arsenic, chromium, cobalt, copper, manganese, mercury, nickel, thallium, vanadium, and zinc were added to the agenda. Results and conclusion: The frequency distribution of the metals in the earthworms was characterized statistically. For the first time state-wide background values, normal values and threshold values were established for all the elements measured. A comparable study with a similar range of parameters is known ...

2006-08-15

391

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal B}(B^+ -> \\phi K^+ \\gamma) = (2.48 ...

2011-01-01

392

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered ...

1993-06-01

393

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the ...

1994-07-01

394

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered ...

1993-01-01

395

Microstructure and electrical properties of iron oxide thin films deposited by spray pyrolysis  

International Nuclear Information System (INIS)

Microstructure and electrical properties of iron oxide Fe_2O_3 thin films prepared by spray pyrolysis method have been experimentally characterized. The effect of substrate temperature as well as deposition time on the structural features (crystallite size and microstrain) and electric resistivity of these films has been investigated. X-ray diffraction (XRD) and scanning electron microscope (SEM) characterized the structure study. The results of X-ray diffraction showed that with increasing substrate temperature bias the film structure changed from amorphous to crystalline at the same deposition time. At a substrate temperature of 350 deg. C and low deposition time, #alpha#-Fe_2O_3 appears almost in amorphous form. With rising the substrate temperature and deposition time, the crystallinity was improved. At T_s_u_b>350 deg. C, a well-crystallized rhombohedral phase of #alpha#-Fe_2O_3 was obtained. ...

2004-01-15

396

Experimental study of lipiodol ultra-fluid. On its signal intensity in MR imaging  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at ...

1988-11-01

397

Theoretical and scaling factors methods to calculate the radioactivity in operational waste streams from Unit 1 at Cernavoda NPP  

International Nuclear Information System (INIS)

The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents and daughters) is ...

2009-05-27

398

Review of integral data on higher transactinides  

International Nuclear Information System (INIS)

A review of the status of integral measurements is presented for "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1Am and "2"4"3Am. This review includes integral measurements pertinent to thermal reactor systems, i.e., thermal cross sections and resonance integrals, as well as measurements for fast reactor systems. It appears that for these nuclides the data for thermal reactors are in good shape; however, more work is recommended in defining the branching ratio of the capture cross section of "2"4"1Am to the isomeric and ground states of "2"4"2Am. Also, benchmark irradiation data are needed for cross section data testing using depletion/production codes. For fast reactors, experiments are in progress, in the UK, in France, and also in the US, with partial results available at this time. Fast integral data obtained from these measurements will be very beneficial. The recommendation pertaining to ...

1979-05-01

399

Principles of the measurement of residual stress by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a ...

1996-11-01

400

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...

2005-11-15

401

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The accuracy of TGS is better ...

2005-11-01

402

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...

1976-05-21

403

Measurement and analysis of temperature, strain and stress of foundation mat concrete in nuclear and thermal power stations  

International Nuclear Information System (INIS)

The problems of the thermal stress in concrete structures are roughly divided into the initial stress due to setting heat and the stress due to external temperature after hardening. The initial stress exists in every concrete structure, and it is usually neglected in beams and columns, but it must be taken into account in case of the foundation mat structures in nuclear power stations, for example. In this paper, (1) the results of measurement of temperature, strain and stress in each lift at the time of and after placing concrete in the foundation mat of a nuclear power station and the comparison of them with the results of analysis, (2) the results of measurement of the temperature and stress in a foundation mat, which was carried out to rationalize the design method for the raft type foundation mats in thermal power stations, and (3) the results of examination on the analysis model, external force conditions and boundary ...

404

Light Sterile Neutrino Effects at theta_13-Sensitive Reactor Neutrino Experiments  

CERN Document Server

We study the impact of very light sterile neutrinos (Delta m^2_new around 1 to 10 times 10^(-2) eV^2, sin^2 2theta_new<10^(-1)) on upcoming theta_13-driven reactor antineutrino experiments like Double-CHOOZ and Daya Bay. Oscillations driven by these vales of Delta m^2_new affect data in the near and far detectors differently and hence potentially modify the capability of these experimental setups to constrain and measure sin^2 2theta_13. We find that the hypothesis theta_new different from zero negatively impacts one's ability to either place an upper bound on sin^2 2theta_13 in the advent of no oscillation signal or measure sin^2 2theta_13 if a theta_13-driven signal is observed. The impact of sterile neutrino effects, however, depends significantly on one's ability to measure the recoil positron energy spectrum. If sin^2 2theta_new is larger than 10^(-2), upcoming theta_13-driven reactor ...

2008-01-01

405

Lifetime and {ital g}-factor measurements of the 11{sup {minus}} isomer in {sup 92}Tc  

Energy Technology Data Exchange (ETDEWEB)

The half-life ({ital T}{sub 1/2}) and {ital g} factor of the 2002 keV 11{sup {minus}} isomer in the odd-odd nucleus {sup 92}Tc produced by the pulsed heavy-ion reaction {sup 68}Zn({sup 28}Si,{ital p}3{ital n}){sup 92}Tc have been measured using time differential perturbed angular distribution method. The measured {ital T}{sub 1/2} value is 3.15(20) ns. From the observed spin precession frequency {omega}{sub {ital L}} of a {sup 92}Tc recoil implanted into a ferromagnetic Ni host, we obtain the {ital g} factor to be 0.806(20). The measured value of the {ital g} factor is in good agreement with a shell model analysis carried out using {pi}({ital p}{sub 1/2}{ital g}{sub 9/2}) and {nu}({ital p}{sub 1/2}{ital g}{sub 9/2}) orbitals for the proton particles and neutron holes outside the {sup 88}Sr core. {copyright} {ital 1996 The American Physical Society.}

1996-12-01

406

Lessons from the private sector on performance-based management  

Energy Technology Data Exchange (ETDEWEB)

Implementation of the Government Performance and Results Act of 1993 (GPRA) has provided a unique challenge for Federal Agencies, such as the Department of Energy (DOE) Office of Waste Management (OWM). While performance measurement, as required by GPRA, is new to Federal Agencies, private industry has applied it at all organizational levels to better manage their operations for some time. There has been significant discussion about how the private sector uses performance measures, but there have been very few empirical studies systematically examining their use. To gather information on comparable private industry practices, waste management industry firms were surveyed through questionnaires and follow-on interviews. Questionnaires were sent to 75 waste management firms throughout the United States and Canada. Twenty-four percent of the firms responded to the questionnaire and participated in the follow-on interviews. The ...

1996-03-01

407

Indoor thoron and radon concentration measurements with passive cup monitors  

International Nuclear Information System (INIS)

A new type of passive integrating cup monitors was developed to measure indoor thoron("2"2"0Rn) and radon("2"2"2Rn) concentrations. By placing a pair of cup monitors with different size a air exchange windows in the same place during a sufficient period of time the concentrations of both gases can be assessed from the alpha track densities on the CN films of the two monitors. The lower detection limit with a 3 months measurement period is for "2"2"0Rn 26.1 Bq*m"-"3 and is for "2"2"2Rn 6.1 Bq*m"-"3. Radon-220 and "2"2"2Rn concentrations have been measured in about 20 different types of dwellings around the Nagoya area with these monitors. The results suggest that the "2"2"0Rn concentrations were rather high in traditional Japanese dwellings made of a timber frame and mud. (orig.). (4 refs., 4 figs.).

1993-07-04

408

Electron-impact excitation of multiply-charged ions using energy loss in merged beams: e+Si"3"+(3s"2S_1_/_2)#->#e+Si"3"+(3p"2P_1_/_2_,_3_/_2)  

International Nuclear Information System (INIS)

For the first time absolute total cross sections for electron-impact excitation of a multiply-charged ion have been measured using an electron-energy-loss technique. Measurements were made near threshold for the process e + Si"3"+(3s"2S_1_/_2) #-># e+Si"3"+(3p"2P_1_/_2_,_3_/_2)-8.88 eV. The 10"-"1"5 cm"2 measured cross section agrees with results of 7-state close coupling calculations to better than the #+-#20% (90% CL) total uncertainty of the measurements. Convoluting the theoretical curve with a Gaussian energy distribution indicates an energy width of 0.15 < or approx. #DELTA#E < or approx. 0.20 eV. (orig.).

409

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the ...

1978-04-01

410

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with ...

2001-06-01

411

Cavity detection based on EM migration of TEM data; TEM ho data no denji migration ni yoru kudo kenshutsu no kokoromi  

Energy Technology Data Exchange (ETDEWEB)

With an objective to discuss applicability of resistivity imaging using electromagnetic migration to detection of underground cavity, an applicability test was carried out on calculation of a numerical model and measurement data. By using the numerical model, a calculation was performed on a hypothetical case that a cubic cavity with sides each at 40 m exists in a homogenous medium of 200 ohm-m, with the cavity top located 20 m below the ground surface. As a result, it was possible to structure in a very short calculation time an image of the cavity which cannot be identified by one-dimensional inverse analysis. In the case of this cavity, a center of the image was structured on its lower face. It was shown that a location to indicate the image must be changed according to difference in the measurement locations. In a test on data measured in an underground cavity in the city of Utsunomiya, Tochigi ...

1997-05-27

412

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China ...

2008-05-01

413

Use of measured time delays in gravitational lenses to determine the hubble constant  

Energy Technology Data Exchange (ETDEWEB)

Gravitational lenses are rare in the known samples of quasars, indicating that the conditions involved in their formation are unusual. In particular, the distribution of matter along the light rays from the observer through the deflector to the quasar may be very different from mean conditions. We show that reasonable deviations in the density of matter along the beams can significantly alter the relationship between time delays and the Hubble constant (H/sub 0/) and conclude that gravitational lenses are not promising estimators of H/sub 0/. However, should an independent, precise determination of H/sub 0/ become available, gravitational lenses could be used to probe long-range density fluctuations.

1985-04-15

414

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

Energy Technology Data Exchange (ETDEWEB)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860[degrees]C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

1993-08-01

415

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

International Nuclear Information System (INIS)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860 degrees C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

416

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-01-01

417

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-09-01

418

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

419

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

420

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

421

The probability distribution of cluster formation times and implied Einstein Radii  

CERN Document Server

We provide a quantitative assessment of the probability distribution function of the concentration parameter of galaxy clusters. We do so by using the probability distribution function of halo formation times, calculated by means of the excursion set formalism, and a formation redshift-concentration scaling derived from results of N-body simulations. Our results suggest that the observed high concentrations of several clusters are quite unlikely in the standard Lambda CDM cosmological model, but that due to various inherent uncertainties, the statistical range of the predicted distribution may be significantly wider than commonly acknowledged. In addition, the probability distribution function of the Einstein radius of A1689 is evaluated, confirming that the observed value of ~45" +/- 5" is very improbable in the currently favoured cosmological model. If, however, a variance of ~20% in the theoretically predicted value of the virial radius is assumed, than the ...

2008-01-01

422

The new JET phased ICRH array: first experiments and modelling  

Energy Technology Data Exchange (ETDEWEB)

New ICRH antennas on JET were designed to couple to the new JET divertor plasma configurations and to improve the Fast Wave Current Drive (FWCD) capabilities. The A2 antenna consists of 4 straps whose currents can be phased at arbitrary angles. The real time automatic tuning acts on frequency, line length (line phase shifters) and stub length. Provision is made for the coupling resistance/plasma position feedback to accommodate the fast changes in antenna loading. The first coupling, tuning and heating results are reported in 0{pi}0{pi}, 0000 and 00{pi}{pi} phasing. A new antenna model is described, which was developed to simulate the measured antenna loading in terms of plasma parameters and to provide a starting point for the real time automatic tuning. 5 refs., 4 figs.

1994-07-01

423

The influence of ultrasound on the fluoroquinolones antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...

2011-01-01

424

The effects of various cooling strategies on surface roughness and tool wear during soft materials milling  

British Library Electronic Table of Contents (United Kingdom)

This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...

2009-01-01

425

Stop-and-go kinetics in amyloid fibrillation  

CERN Document Server

Many human diseases are associated with protein aggregation and fibrillation. We present experiments on in vitro glucagon fibrillation using total internal reflection fluorescence microscopy, providing real-time measurements of single-fibril growth. We find that amyloid fibrils grow in an intermittent fashion, with periods of growth followed by long pauses. The observed exponential distributions of stop and growth times support a Markovian model, in which fibrils shift between the two states with specific rates. Remarkably, the probability of being in the growing (stopping) state is very close to 1/4 (3/4) in all experiments, even if the rates vary considerably. This finding suggests the presence of 4 independent conformations of the fibril tip; we discuss this possibility in terms of the existing structural knowledge.

2009-01-01

426

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit ...

1998-06-18

427

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

428

Photosynthetic energy storage efficiency in Chlamydomonas reinhardtii, based on microsecond photoacoustics  

British Library Electronic Table of Contents (United Kingdom)

Using a novel, pulsed micro-second time-resolved photoacoustic (PA) instrument, we measured thermal dissipation and energy storage (ES) in the intact cells of wild type (WT) Chlamydomonas reinhardtii, and mutants lacking either PSI or PSII reaction centers (RCs). On this time scale, the kinetic contributions of the thermal expansion component due to heat dissipation of absorbed energy and the negative volume change due to electrostriction induced by charge separation in each of the photosystems could be readily distinguished. Kinetic analysis revealed that PSI and PSII RCs exhibit strikingly different PA signals where PSI is characterized by a strong electrostriction signal and a weak thermal expansion component while PSII has a small electrostriction component and large thermal expansion....

2011-01-01

429

Photobioreactor for cultivation and real-time, in-situ measurement of O2 and CO2 exchange rates, growth dynamics, and of chlorophyll fluorescence emission of photoautotrophic microorganisms  

British Library Electronic Table of Contents (United Kingdom)

A detailed knowledge about the dynamics of phytoplanktonic photosynthesis and respiration is crucial for the determination of primary productivity in open oceans as well as for biotechnological applications. The dynamics are best studied in photobioreactors that are able to simulate natural conditions in such, that light can be modulated not only diurnally but also mimicking effects of solar elevation angle from sunrise to sunset, variable cloudiness, light modulation in refractory sun flecks due to water waves, or light intermittence due to turbulent flow in dense suspensions. In addition, high performance photobioreactors ought to be able to monitor in real time photosynthetic and respiratory activities as well as culture growth. Here, we demonstrate performance of a newly designed bench...

2009-01-01

430

Paramagnetic properties of the RCo_2 compounds (R = rare earth)  

International Nuclear Information System (INIS)

The paramagnetic susceptibilities of all the RCo_2 compounds for which measurements are available are found to obey a Curie-Weiss law consistent with the modified indirect exchange model. The rare-earth ions are in a well defined tripositive valence state. Paramagnetic moments and paramagnetic Curie temperatures are obtained for these materials for the first time. The paramagnetic moments of these materials are changed from their free-ion values by the effects of itinerant electron polarisation, an effect which is particularly large for SmCo_2 whose paramagnetic moment is almost three times greater than the free-ion value. The modified indirect exchange model is found to be able to give a full description of the magnitude of the rare-earth, cobalt and diffuse moments in polarised neutron experiments. The band structures of the light RCo_2 compounds are found to be distinctly different to those of the heavy RCo_2 compounds. ...

1984-03-01

431

Mechanisms involved in the antinociception of petroleum ether fraction from the EtOH extract of Chrysanthemum indicum in mice  

British Library Electronic Table of Contents (United Kingdom)

The petroleum ether fraction (PEF) from the EtOH extract of flowers and buds of Chrysanthemum indicum was evaluated on antinociception in mice using chemical and thermal models of nociception. PEF administered orally at doses of 188 and 376mg/kg produced significant inhibitions on chemical nociception induced by intraperitoneal acetic acid, subplantar formalin or capsaicin injections and on thermal nociception in the tail-flick test and the hot plate test. In the pentobarbital sodium-induced sleep time test and the open-field test, PEF neither enhanced the pentobarbital sodium-induced sleep time nor impaired the motor performance, indicating that the observed antinociception was unrelated to sedation or motor abnormality. In a measurement of core body temperature, PEF did not affect temper...

2011-01-01

432

Measurement of Lake Roosevelt biota in relation to reservoir operations. Appendices 1991  

International Nuclear Information System (INIS)

This report consists of appendices A-F containing the biological data which were collected from Lake Roosevelt, Washington. The data are to be used in the design of a computer model that would predict biological responses of reservoir operations as part of the System Operation Review program. Major components of the model included: Quantification of impacts to phytoplankton, zooplanktons, benthic invertebrates, and fish caused by reservoir drawdowns and low water retention times; quantification of number, distribution, and use of fish food organisms in the reservoir by season; determination of seasonal growth of fish species as related to reservoir operations, prey abundance and utilization; and quantification of entrainment levels of zooplankton and fish as related to reservoir operations and water retention times.

1995-11-05

433

Internal friction of amorphous Pd/sub 80/ Si/sub 20/ metal doped with hydrogen isotopes  

Energy Technology Data Exchange (ETDEWEB)

Internal friction of amorphous Pd/sub 80/Si/sub 20/ metal doped with hydrogen or deuterium was measured with a specially designed apparatus using amorphous metal sheet as a part of the electric oscillating circuit. Two peaks in Q/sup -1/ curve are observed. Applying the peak shift method to the first Snoek-like peak, we can determine the relaxation time from which the microdiffusion coefficient can be calculated. The obtained microdiffusion coefficient is about 10/sup -14/ m/sup 2//s at 200 K, being comparable with the macrodiffusion coefficient obtained from the releasing method. It can, however, not elucidate the hydrogen isotopic effect on the peak temperature of Q/sup -1/ curve, the activation energy for relaxation and the relaxation time from the present work because of the broadness of obtained Q/sup -1/ curve.

1983-02-01

434

Injection control and thermally stimulated current in ionic polarized polymer based light emitting diode  

International Nuclear Information System (INIS)

An effective method of enhancing charge injection and electroluminescence efficiency of polymer-based light emitting diode is introduced. Spin-coated films of poly (N-vinylcarbazole) blended with electron-transport material (Bu-PBD), laser dye (Coumarin6), and the typical supporting electrolyte (tetraethylammonium perchlorate; TEAP) were examined and it was found that the injection current and luminance of the light emitting diode doped with TEAP were enhanced dramatically after heat-treatment at 80 deg. C and appropriate biasing in an external electric field of 1.5x10"8 V/m at this temperature. The thermally stimulated current (TSC) was also measured to investigate the relaxation process of ionic space charges in the films. The relaxation times of ionic polarization were found to be related to the cation size of the electrolyte. And the relaxation time becomes long enough by the use of TEAP doping.

2003-08-22

435

High temperature properties of ceramics in the SiAlON system  

International Nuclear Information System (INIS)

A series of SiAlON materials with a cordierite-based matrix were annealed for different lengths of time to cause crystallization of the glass phase. Their fracture toughness, hardness, and elastic modulus were measured from room temperature up to 1100"0C. The fracture toughness generally decreased with temperature. Short time annealing raised toughness at lower temperatures, while further annealing lowered it back to the value for as-hot pressed materials. At higher test temperatures annealing had no effect on toughness. This annealing behavior is significantly different from that previously reported in the system SaAlON-YAG. Hardness decreased monotonically with temperature for all samples. Both hardness and the elastic modulus were not affected by the annealing treatment. At elevated temperatures appreciable scatter of modulus results allowed only a rough trend of decrease with temperature to be observed.

436

Gravitational Waves  

International Nuclear Information System (INIS)

Gravitational waves are propagating fluctuations of gravitational fields, that is, '' ripples '' in space-time, generated mainly by moving massive bodies. These distortions of space-time travel with the speed of light. Every body in the path of such a wave feels a tidal gravitational force that acts perpendicular to the wave's direction of propagation; these forces change the distance between points, and the size of the changes is proportional to the distance between these points thus gravitational waves can be detected by devices which measure the induced length changes. The frequencies and the amplitudes of the waves are related to the motion of the masses involved. Thus, the analysis of gravitational waveforms allows us to learn about their source and, if there are more than two detectors involved in observation, to estimate the distance and position of their source on the sky. (author)

2007-12-01

437

GaAs pattern etching with little damage by a combination of Ga"+focused-ion-beam irradiation and subsequent Cl_2 gas etching  

International Nuclear Information System (INIS)

Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.

438

GaAs pattern etching with little damage by a combination of Ga sup + focused-ion-beam irradiation and subsequent Cl sub 2 gas etching  

Energy Technology Data Exchange (ETDEWEB)

Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.

1990-12-15

439

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-01-01

440

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-12-31

441

Flood scour monitoring system using fiber Bragg grating sensors  

Science.gov (United States)

The exposure and subsequent undermining of pier/abutment foundations through the scouring action of a flood can result in the structural failure of a bridge. Bridge scour is one of the leading causes of bridge failure. Bridges subject to periods of flood/high flow require monitoring during those times in order to protect the traveling public. In this study, an innovative scour monitoring system using button-like fiber Bragg grating (FBG) sensors was developed and applied successfully in the field during the Aere typhoon period in 2004. The in situ FBG scour monitoring system has been demonstrated to be robust and reliable for real-time scour-depth measurements, and to be valid for indicating depositional depth at the Dadu Bridge. The field results show that this system can function well and survive a typhoon flood.

2006-12-01

442

Expert judgement of uncertainties in modelling emergency actions after nuclear accidents  

Energy Technology Data Exchange (ETDEWEB)

Sheltering, evacuation and distribution of stable iodine tablets are considered to be major early emergency actions aiming at diminishing the consequences after a release of radioactive materials from nuclear power plants into the air. Whether in real situations emergency managers will act accordingly is hard to predict. Uncertainties associated with these decisions are termed 'volitional' uncertainties. These uncertainties, however, cannot be assessed by expert judgements as they express the decision at stake in an emergency situation. Uncertainties on the times to implement countermeasures and on the times for the general population to respond to these measures can be assessed by experts, as they represent 'lack-of-knowledge' uncertainties. This paper describes the difference in approach of both types of uncertainties and shows the results of expert judgements on the latter type of ...

2000-07-01

443

Empirical relationship between track diameter and etching time for fission fragments incident on a glass SSNTD at various angles of incidence  

Energy Technology Data Exchange (ETDEWEB)

Geometrical shapes and diameter of nuclear tracks changes continuously during the process of etching for various incident angles. Besides, there is also a marked difference amongst their profiles, as evidenced by the SEM analysis, when the incoming particles fall on the detector at different angles of incidence. This work outlines this aspect of fission fragment tracks in a glass detector and has set out a few empirical relationships between the mean track diameter, d-bar and the etching time, t, within experimental limits. This study, therefore, sheds some light in the follow up the origins and characteristics of heavy ions in some terrestrial and extra-terrestrial materials and also in studying the collimation accuracy of heavy ion bombardments. The implications of the results in discerning the measurements of incident angles of various types of ions are described in detail in the paper.

1983-09-01

444

Effect of the temperature and of the loading time on the strength and fracture of mild steel and steels St. 3 and 12Kh18N10T in spalling  

Energy Technology Data Exchange (ETDEWEB)

The authors obtain the critical load levels corresponding to the onset of spalling microdamage for Armco iron and steels St.3 and 12Kh18N10T in a broad temperature range (-196-800 degrees C. The results of the investigation of the effect of the temperature on spalling fracture are presented. The effect of the loading time on the strength of the investigated materials is also given. The authors assume that at -196 degrees C impact-wave strain-hardening may also be characterized by the value of H obtained for the center of the specimen since measurements on great thicknesses, including those reaching as far as the opposite surface, did not reveal any substantial change of microhardness.

1986-02-01

445

Design and development of an innovative hybrid powder based on a computer simulation and its application to foundation makeup products  

British Library Electronic Table of Contents (United Kingdom)

An innovative hybrid powder prepared using computer simulation allowed development of a new foundation having a fine, smooth texture that has never been achieved before. The optical structure/design of the powder was based on the results of measurements and analyses conducted on the optical characteristics of a baby's delicate skin, which is the envy of many women. To obtain the optimal optical characteristics, the finite differential time domain (FDTD) method for solving Maxwell's differential equation by difference and time domain was applied to the computer simulation method. For synthesis of the hybrid powder based on the optical model, a proprietary shape regulation coating technology was used in which flaky substrates were coated with microspherical forms of barium sulfate crystals. ...

2008-01-01

446

Combustion of jojoba methyl ester in an indirect injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation has been carried out to examine for the first time the performance and combustion noise of an indirect injection diesel engine running with new fuel derived from pure jojoba oil, jojoba methyl ester, and its blends with gas oil. A Ricardo E6 compression swirl diesel engine was fully instrumented for the measurement of combustion pressure and its rise rate and other operating parameters. Test parameters included the percentage of jojoba methyl ester in the blend, engine speed, load, injection timing and engine compression ratio. Results showed that the new fuel derived from jojoba is generally comparable and a good replacement to gas oil in diesel engine at most engine operating conditions, in terms of performance parameters and combustion noise produced. (author)

2003-07-01

447

An experimental study on stable flow control for multi-stage expansion device  

Energy Technology Data Exchange (ETDEWEB)

An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.

1998-04-01

448

An amusing analogy: modelling quantum-type behaviours with wormhole-based time travel  

Energy Technology Data Exchange (ETDEWEB)

When backward time travel through wormholes is taken into account, classical physics loses its determinism and allows simulation of some quantum behaviours. We show how it is possible to simulate a non-local wavefunction reduction-type effect, i.e. we present a mechanical analogy for the collapse of the wavefunction of an entangled state of two removed particles. This situation can be seen as the simplest EPR situation, i.e. the situation where there is just one direction to measure along the spin (or the correlated properties). We present no rigorous results here, just a different point of view about something that is generally thought to be impossible: modelling a quantum indeterministic and non-local behaviour with a mechanical system.

2002-08-01

449

A gear fault diagnosis using Hilbert spectrum based on MODWPT and a comparison with EMD approach  

British Library Electronic Table of Contents (United Kingdom)

When gear fault occurs, the vibration signals always display non-stationary behavior. Therefore time-frequency analysis has become the well-accepted technique for vibration-based gear fault diagnosis. This paper presents the application of a new time-frequency signal processing technique, the Hilbert spectrum based on the maximal overlap discrete wavelet packet transform (MODWPT), to the analysis of simulation signals and gear fault vibration signals measured by the acceleration sensor fixed on the bearing house. As long as the decomposition scale and disjoint dyadic decomposition are chosen suitably, the original signal could be decomposed into a set of monocomponent signals whose instantaneous amplitude and instantaneous frequency own physical meaning. After the instantaneous amplitude a...

2009-01-01

450

1992 Conversion Resources Supply Document  

Energy Technology Data Exchange (ETDEWEB)

In recent years conservation of electric power has become an integral part of utility planning. The 1980 Pacific Northwest Electric Power Planning and Conservation Act (Northwest Power Act) requires that the region consider conservation potential in planning acquisitions of resources to meet load growth. The Bonneville Power Administration (BPA) developed its first estimates of conservation potential in 1982. Since that time BPA has updated its conservation supply analyses as a part of its Resource Program and other planning efforts. Major updates were published in 1985 and in January 1990. This 1992 document presents updated supply curves, which are estimates of the savings potential over time (cumulative savings) at different cost levels of energy conservation measures (ECMs). ECMs are devices, pieces of equipment, or actions that increase the efficiency of electricity use and reduce the amount of electricity used by ...

1992-03-01

451

Studies of aerosol formation in power plant plumes - II. Secondary aerosol formation in the Navajo generating station plume  

Energy Technology Data Exchange (ETDEWEB)

Aerosol and gas measurements were made with the University of Minnesota Mobile Laboratory (UMML) during the VISTTA programme near Page, Arizona. The UMML was stationed on Zilnez Mesa approx. 65 km east of the Navajo coal-fired power plant. Measurements were made both in and out of the power plant plume and were made during the day and night. Measured parameters included aerosol size distributions, Aitken nuclei count, ozone and sulphur dioxide concentrations, the aerosol light scattering coefficient, and meteorological parameters including ultraviolet radiation intensity. Concentrations of NO and NO/SUB/x were occasionally measured. Data show clear evidence of gas-to-particle conversion in the plume with aerosol volume being added in the 0.01 MUm - 0.32 MUm dia. range and new particles being formed. The observed excess aerosol volume depends strongly upon the SO/SUB/2 concentrations and the ...

1981-01-01

452

Measuring q sub 0 using supernovae at z approx 0. 3  

Energy Technology Data Exchange (ETDEWEB)

The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate ...

1992-07-01

453

Measurement of the population densities in Gd atomic vapor using diode laser absorption spectroscopy in UV transitions  

International Nuclear Information System (INIS)

We report on the ultraviolet laser absorption spectroscopy of atomic Gd at 394-554 nm where two transition lines are place very closely by using a frequency-doubled beam of external-cavity diode laser (ECDL). One is from 999.121 to 26337.071 cm-1 and the other from 0 to 25337.755 cm-1. If two transition lines are placed closely within a continuous fine tuning range, the real-time measurement of the atomic excitation temperature is possible without any significant time consumption because at least two transition lines originating from different low-lying energy levels need to be investigated for the Boltzmann-plot. Since the spectral difference between the two transitions is only about 0.195 cm-1 (5.85 GHz), it is possible to record both the absorption spectra simultaneously as shown in Fig. 1. But the transition probabilities (or oscillator strengths) of these lines have not been measured accurately yet ...

2003-11-07

454

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)

2005-11-23

455

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating ...

2010-06-15

456

Thermal noise as a spectroscopic tool to determine transport properties  

British Library Electronic Table of Contents (United Kingdom)

The utilization of thermal fluctuations or Johnson/Nyquist noise as a spectroscopic method to determine transport properties in conductors or semiconductors is developed. The autocorrelation function is obtained from power spectral density measurements thus enabling electronic transport property calculation through the Green-Kubo formalism. This experimental approach is distinct from traditional numerical methods such as molecular dynamics simulations, which have been used to extract the autocorrelation function and directly related physics only. This work reports multi-transport property measurements consisting of the electronic relaxation time, resistivity, mobility, diffusion coefficient, electronic contribution to thermal conductivity and Lorenz number from experimental data. Double va...

2009-01-01

457

The {sup 234}U neutron capture cross section measurement at the n TOF facility  

Energy Technology Data Exchange (ETDEWEB)

The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)

2008-07-01

458

The microscopic dynamics of condensed parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

We have measured the almost-pure incoherent scattering function of liquid and solid parahydrogen, using inelastic neutron scattering. The experiments were carried out on TOSCA, a time-of-flight, inverse-geometry, crystal-analyzer spectrometer, operating on the pulsed neutron source at ISIS (UK). The experiments have been planned taking advantage of the intrinsic incoherence introduced in the scattering process by the rotational transitions. The measured double-differential cross section gives a direct experimental access to the microscopic dynamics of condensed hydrogen. From the high-energy region of the spectrum, where the impulse approximation for the center of mass motion applies, we have been able to extract the translational mean kinetic energy. In the low-energy region, using the Gaussian approximation, we compare the experimental data in the liquid phase with the results of a model for the velocity autocorrelation ...

2002-07-01

459

The effect of a concurrent gas flow on gas-liquid mass transfer  

Science.gov (United States)

A theory for the mass transfer process was developed. It was assumed that the largest convective motions in the flow control the rate of mass transfer. Measurements of mass transfer coefficients for the absorption of oxygen by water films were made for concurrent flows in a horizontal rectangular channel, and for concurrent and free-falling downflow in a one-inch pipe. The measured values of the Sherwood number for concurrent flows were up to three times as great as would be predicted from this relation. This increase in Sherwood number was correlated with a dimensionless group similar to a Martinelli parameter which is characteristic of two phase flows. An explanation for this effect is given in terms of the way that the scales of the convective motions are related to bulk flow parameters.

1977-01-01

460

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the ...

2002-01-01

461

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...

1981-01-01

462

Search for novel origins of cosmic-ray antiprotons and antimatter with BESS-Polar flight over Antarctica  

Energy Technology Data Exchange (ETDEWEB)

The primary aims of the BESS-Polar program are precise measurements of the low-energy antiproton spectrum and search for cosmologically significant antimatter, which would provide new clues to understand the early Universe. The second flight (BESS-Polar II) over Antarctica was successfully carried out in December 2007 - January 2008. We performed 24.5 days scientific observation just at the solar minimum. The payload worked well during the flight and 4.7 billion cosmic-ray events were collected, which corresponds to 10-20 times statistics of the BESS data taken in the previous solar minimum period (1995 and 1997). Based on the BESS-Polar II data, we will present recent preliminary results of cosmic-ray antiproton measurements and sensitive search for antimatter. (authors)

2010-07-01

463

Radon measurements at the FEMP  

Energy Technology Data Exchange (ETDEWEB)

Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.

1993-08-01

464

Phylogenetic constraints on digesta separation: Variation in fluid throughput in the digestive tract in mammalian herbivores  

British Library Electronic Table of Contents (United Kingdom)

The relevance of the mean retention time (MRT) of particles through the gastrointestinal tract (GIT) is well understood and MRTparticleGIT is an important parameter in digestion models. Solute markers have been used to estimate MRTsoluteGIT (or 'fluid passage') in animals, but the relevance of this measure is less evident and is usually sought in its relation to MRTparticleGIT. The ratio between the two measures indicates the degree of 'digesta washing', with little washing occurring at ratios of 1, aborad washing at ratios >1 (where the solute marker travels faster than the particle marker), and orad (retrograde) washing at ratios <1 (where the solute marker travels slower than the particle marker). We analysed digesta washing in a dataset of 98 mammalian species including man of differen...

2011-01-01

465

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

466

Pet keeping and dampness in the dwelling: associations with airway infections, symptoms, and physiological signs from the ocular and nasal mucosa:  

British Library Electronic Table of Contents (United Kingdom)

Abstract The aim was to utilize data from a study of occupational indoor environments to analyze symptoms and physiological signs in relation to the home environment. A medical investigation was performed at the workplace among university staff (n = 173) from four university buildings in Bergen, in March 2004. Tear film break up time (BUT) was measured by two methods. Nasal patency was measured by acoustic rhinometry. Nasal lavage fluid analysis (NAL) included eosinophilic cationic protein (ECP); myeloperoxidase (MPO), lysozyme and albumin. Atopy was assessed by total serum IgE and specific IgE (Phadiatop). Totally 21%, 21%, 18%, 11%, and 27% had weekly ocular, nasal, facial dermal symptoms, headache and tiredness, respectively, 15% had a damp dwelling, and 20% had a cat or dog. Multiple l...

2007-01-01

467

Optimized zinc electrode for the rechargeable zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

For the development of a long-lived, electrically rechargeable zinc-air battery the structure and wettability of pasted zinc electrodes were optimized. Pasted zinc electrodes containing 1 to 10% cellulose, but having almost the same nominal capacities, were prepared and tested in zinc/oxygen cells. The effect of discharge rate on cell voltage and delivered capacity, as well as the maximum power, were measured. Furthermore, cell charge-discharge behaviour and cycle life were examined. After different times of operation, the porosity and the pore size distribution of the pasted zinc electrodes were measured by means of mercury porosimetry. The life cycle and peak power drain capability of the Zn/oxygen battery could be substantially improved by the addition of 10 wt% cellulose to the pasted zinc electrode. (author)

1998-09-01

468

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

469

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

470

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

471

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

472

Neutron inelastic scattering to octupole states in single-closed-shell nuclei  

International Nuclear Information System (INIS)

Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).

473

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

474

Modelling and design of smoothing reactances. Application to air gap length calculation  

Energy Technology Data Exchange (ETDEWEB)

A new method for analysis and design of smoothing reactances utilising two-dimensional planar models is presented in this paper. Inductance and magnetic flux density are calculated, and their results compared with those measured experimentally. The results obtained are good if compared with those measured once the machine have been built. Moreover, the method herein developed is applied to the calculation of air gap lengths in terms of the desired current and inductance. The kind of reactances studied presents windings in both limbs and air gaps in the four corners (joint of limbs and yokes). The main contribution of this paper is the presentation of a method of industrial application, to be easily developed, with a very important reduction in the time of machine calculation (due to the decrease in the number of nodes and elements compared with the three-dimensional model) for the determination of the air gap length in ...

2000-08-01

475

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

476

Measurement of beta-decay half-lives of short-lived nuclei with Spectrum Multi-Scaler (SMS)  

Energy Technology Data Exchange (ETDEWEB)

The half-lives of short-lived nuclei produced by 14 MeV or thermal neutron bombardments were measured with a Ge detector, a Spectrum Multi-Scaler (Laboratory Equipment Corporation SMS-48) and a High-Rate Spectroscopy Amplifier (EG and G ORTEC Model 973) in the multi-scaling mode. The corrections for pile-up and dead-time losses were performed by applying source and pulser methods. The half-lives of {sup 91m}Mo, {sup 97m}Nb, {sup 138}Cs, {sup 139}Ba, {sup 174}Tm and {sup 203m}Pb were determined with accuracy of 0.22-0.6% and the accuracy has been much improved. (author)

1996-03-01

477

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

478

Logistics bottlenecks  

Energy Technology Data Exchange (ETDEWEB)

Many of the vulnerabilities to Energy Access, Energy Security, and Environmental Sustainability result from impediments to reaching a global demand-supply balance, as well as local balances, for various energy sources and carriers. Vulnerabilities result from multiple reasons: regional imbalances of energy production and consumption, the bulky character of the majority of energy fuels, the virtual necessity of electricity consumption following its production, among others. To detect and prioritize respective 'bottlenecks' across energy carriers, they have to be measured. In this report, production, consumption, exports, and imports were measured across all major energy carriers for seven key regions of the world for three time frames-2008, 2020, and 2050. Imbalances between production and consumption form bottlenecks in each region.

2010-09-15

479

Irradiation effects on the electrochemistry and corrosion resistance of stainless steel  

International Nuclear Information System (INIS)

Nickel ion radiation at 500 C was shown to have a strong effect on the surface electrochemistry and intergranular corrosion (IGC) of stainless steel (SS). Measured current densities in a 1 N sulfuric acid solution at room temperature were increased at active-passive, passive, and transpassive potentials. Radiation effects on the current decay behavior and susecptibility to IGC were similar for a fine-grained (FG) S alloy and for a very large-grained (LG) SS. Radiation-induced segregation (RIS) at the surface was believed to promote higher currents at short times, whereas segregation at grain boundaries was responsible for IG attack. Analytical electron microscopy (AEM) measurements revealed chromium and iron depletion plus Ni and silicon enrichment at grain boundaries in irradiated specimens. Si enhanced dissolution at transpassive potentials, whereas Cr depletion did the same at active-passive and passive potentials.

1995-01-01

480

Investigation of GPS/IMU Positioning System for Mining Equipment  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project is to investigate the applicability of a combined Global Positioning System and Inertial Measurement Unit (GPS/IMU) for information based displays on earthmoving machines and for automated earthmoving machines in the future. This technology has the potential of allowing an information-based product like Caterpillar's Computer Aided Earthmoving System (CAES) to operate in areas with satellite shading. Satellite shading is an issue in open pit mining because machines are routinely required to operate close to high walls, which reduces significantly the amount of the visible sky to the GPS antenna mounted on the machine. An inertial measurement unit is a product, which provides data for the calculation of position based on sensing accelerations and rotation rates of the machine's rigid body. When this information is coupled with GPS it results in a positioning system that can maintain positioning ...

2006-09-13

481

High-resolution sequence stratigraphic framework and its characteristic. Case study of C-P coal measures in Hebei  

Energy Technology Data Exchange (ETDEWEB)

The framework of time-sequence stratigraphy was established according to the point of view of high-resolution sequence stratigraphy. The development characteristic of the sequence, the distribution pattern of strata, the basin evolution and filling, and the relationship between variations of base level and coal accumulation of epicontinental basin were expounded based on the base-level cycles. The result shows that the C-P coal measures in Hebei is a series of basin deposit of inner epicontinental sea. The formation and evolution and sedimentation of the basin is intimately related to the changes of the basin base-level, which controls the development of the coal-accumulation, forming a clear coal-bearing sequence in the cycle. 9 refs., 3 figs.

2001-07-01

482

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

483

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

484

G-factor of the 21/2/sup +/ isomer in /sup 203/Pb  

Energy Technology Data Exchange (ETDEWEB)

The g-factor of the 21/2/sup +/ state at 1921.9 keV in /sup 203/Pb has been measured through the time differential perturbed angular distribution technique in an external magnetic field B=2.028 T. The measured g-factor g=-0.063(2) indicates a predominantly three neutron hole configuration described by the wave function 0.68vertical strokei/sup -1//sub 13/2/f/sup -2//sub 5/2/>+-0.73vertical strokei/sup -1//sub 13/2/f/sup -1//sub 5/2/p/sup -1//sub 3/2/>.

1986-12-01

485

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...

1986-04-01

486

Estimation of throughfall erosivity in a highly diverse forest ecosystem using sand-filled splash cups  

British Library Electronic Table of Contents (United Kingdom)

Sand-filled splash cups were used to study the erosive power of rainfall and throughfall in the humid subtropics of Southeast China. The splash cup measurements yielded precise and reproducible results under both open field conditions and forest vegetation. The splash cups were exposed to specific forest stands of different ages and to selected species (Schima superba, Castanopsis eyrei, Daphniphyllum oldhamii, Lithocarpus glaber) in the Gutianshan (???) National Nature Reserve (GNNR). The results of the measurements under forest vegetation show that the erosive power of throughfall drops to be 2.59 times higher compared to the open field. This accentuates the importance of shrub, herb and litter layers in forest ecosystems to protect the soil against erosion. Coalescing drops from leaves ...

2010-01-01

487

Estimation of plasma density by surface plasmons for surface-wave plasmas  

International Nuclear Information System (INIS)

An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)

2008-12-01

488

Emerging trends in information and communication technology in mine safety and disaster management  

British Library Electronic Table of Contents (United Kingdom)

There is tremendous growth in the use of Geographic Information Systems (GIS), Global Positioning Systems (GPS), Remote Sensing, Satellite Communication, and Modeling & Simulation techniques. These tools and techniques helps significantly in characterizing infrastructure, risk area and disaster zones, planning and implementation of hazards reduction measures etc. Communication satellites becomes vital for providing emergency communication and timely relief measures. Integration of space technology inputs into natural disaster monitoring and mitigation mechanisms is critical for hazard reduction. This paper mainly focused on all the issues described above. Major emphasis had been given to the recent developments in information & communication technology enabled tools and their applications ...

2010-01-01

489

Eluates from pyrolysed refuse. Eluate aus pyrolysiertem Hausmuell  

Energy Technology Data Exchange (ETDEWEB)

The solubility behavior of solid residues from the heat treatment of domestic rubbish was examined by simulated precipitation in laboratory lysimeters. The precipitation corresponded to the average amount of rain in West Germany and was applied at different time periods. Specific soil characteristics, the value of k/sub f/ and the water retention capacity was determined in this way. In parallel with the lysimeter flood ions, extraction (by batch process) was done, in order to find the maximum solubility of the materials used. It was found that for pyrolysis residues from reactor temperatures of 450/sup 0/ to 1000/sup 0/C, a greater solubility was measured than for slag from combustion. The eluates from these residues gave information about the degree of contamination or on the solubility of the measured parameters and materials in organoleptic, physical, organic and inorganic examinations. The concentrations of harmful ...

1981-01-01

490

Electronic structure, Compton profiles and optical properties of TaC and TaN  

International Nuclear Information System (INIS)

Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.

2010-11-01

491

Electron-impact excitation of Si"3"+(3s#->#3p) using a merged-beam electron-energy-loss technique  

International Nuclear Information System (INIS)

For the first time, absolute cross sections for electron-impact excitation of a multiply charged ion have been measured using an electron-energy-loss technique. Cross sections for e+Si"3"+(3s "2S_1_/_2)#->#e+Si"3"+(3p "2P_1_/_2_,_3_/_2)-8.88 eV have been measured with an accuracy of #+-#20% (at 90% confidence level) over a narrow energy range (#+-#0.6 eV) about the threshold energy with an energy resolution of 0.2 eV. Results are in good agreement with close-coupling calculations.

492

Dimensional stability, optical and elastic properties of MgAl{sub 2}O{sub 4} spinel irradiated in FFTF to very high exposures  

Energy Technology Data Exchange (ETDEWEB)

Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.

1993-10-01

493

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

494

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

495

Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results ...

1986-09-01

496

Chemical transformations of organic matter during the composting of wood industry wastes (residues); Transformacoes quimicas da materia organica durante a compostagem de residuos da industria madeireira  

Energy Technology Data Exchange (ETDEWEB)

Composting of sawdust and paper mill sludge, using a 'Kneer' process reactor, was studied in an attempt to elaborate upon organic matter transformation during the process and to define parameters to measure the compost maturity level. Temperature, electron paramagnetic resonance data, ash and C, H, N and S contents, and a spectroscopic method using ultraviolet-visible (UV-VIS) for alkaline (pH = 8.5) and solid samples was used to study the maturity of the compost samples. These parameters were measured in 6 humic acids extracted from the compost samples during 29 days. The results of this work show that the 'Kneer' process is efficient in transforming ligno-celulitic residues in a short time (29 days), into an organic fertilizer material with application perspectives (author)

2004-06-01

497

Biochemical alterations induced by Zn and Cd individually or in combination in the serum of Oreochromis niloticus  

British Library Electronic Table of Contents (United Kingdom)

Measurement of serum biochemical parameters in response to metal exposures can be especially useful to help identify target organs of toxicity as well as the general health status of animals. Oreochromis niloticus were exposed to 5.0?mg/L?Zn, 1.0?mg/L?Cd, and 5.0?mg/L?Zn?+?1.0?mg/L?Cd mixture for 7 and 28?days, and alterations in serum enzyme activities and ion levels were measured. Significant changes in all the biochemical parameters were found to be time dependent. Following metal exposure, alkaline phosphatase activity was elevated at both exposure periods. No changes in activities of lactate dehydrogenase and lipase were observed in response to single or combined Zn and Cd exposure at 7?days while they increased at 28?days. Fish exposed to metals showed a decrease in cholinesterase ac...

2010-01-01

498

Application of FFT-based Algorithms for Large-Scale Universal Kriging Problems  

British Library Electronic Table of Contents (United Kingdom)

Looking at kriging problems with huge numbers of estimation points and measurements, computational power and storage capacities often pose heavy limitations to the maximum manageable problem size. In the past, a list of FFT-based algorithms for matrix operations have been developed. They allow extremely fast convolution, superposition and inversion of covariance matrices under certain conditions. If adequately used in kriging problems, these algorithms lead to drastic speedup and reductions in storage requirements without changing the kriging estimator. However, they require second-order stationary covariance functions, estimation on regular grids, and the measurements must also form a regular grid. In this study, we show how to alleviate these rather heavy and many times unrealistic restr...

2009-01-01

499

A method for measuring effective radon diffusion coefficients in radon barriers by using modified Lucas cells  

Energy Technology Data Exchange (ETDEWEB)

Radon proof barriers are used for lowering of radon transport from the soil into the house and the determination of the radon diffusion coefficient is an important parameter to be determined in order to design the minimal thickness of the radon proof insulation. A method has been developed in our laboratory by using modified Lucas cells connected to a radon source and tightly closed onto the top by the tested membranes whose radon diffusion coefficients are being measured. Solving the time-dependent differential equation for radon diffusion in the membrane for well-defined experimental conditions the effective radon diffusion coefficient of the insulating material can be evaluated by comparing the radon concentration decrease in the cell for the first hours with the well-known radioactive decay. First results obtained in several preliminary tests carried out with a parafilm M barrier and two polyethylene membranes are shown in this paper.

2005-01-01

500

Radiocardiographic measurement of minimum central transit times by means of indium-113m-DTPA and of a 8-crystal radiocardiograph (Gamma Retina VI)  

International Nuclear Information System (INIS)

The minimum cardiac transit times (MTT's) at rest and following sub-maximum stresses were measured in 97 individual examinations of untrained persons and high performance athletes. It turned out that there is a strong dependence on cardiac frequency of the MTT's. This relation can be described quite satisfactorily by a hyperbolic function and in this way allows a frequency correction to be made of the MTT's. The MTT's standardized in this way (MTT.f values) represent the quotient of the end diastolic segment volume/beat volume. In the whole lesser circulatory system almost identical MTT.f values were found for the two groups under comparison at rest and following stress. In the ventricles, however, and especially so in the left ventricle, the MTT.f values were clearly higher with athletes than with untrained persons, but they strongly decreased after stresses, while the respective values remained almost constant in ordinary persons. (orig./RF).