JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469
Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner
1993-01-01
Adaptive Image Processing A Computational Intelligence Perspective
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
2009-01-01
Optical image storage in ion implanted PLZT ceramics
International Nuclear Information System (INIS)
We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible ...
Lichen striatus - close-up (image)
Lichen striatus begins similarly to lichen planus, with small bumps (papules), but over a period of days expands to form a long streak or band of affected ...
Energy Technology Data Exchange (ETDEWEB)
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and ...
2007-10-15
Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging
International Nuclear Information System (INIS)
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
International Nuclear Information System (INIS)
Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a ...
1998-07-01
Image-enhancement applications at the Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
1982-06-01
Subsurface imaging using the spectral polarization difference technique and NIR illumination
Energy Technology Data Exchange (ETDEWEB)
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
1999-01-26
Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band
British Library Electronic Table of Contents (United Kingdom)
The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...
2008-01-01
TO: All GCN Notice recipients RE
These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...
THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
Position-sensitive proportional counter for space-based X-ray imaging studies
International Nuclear Information System (INIS)
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
2005-03-01
International Nuclear Information System (INIS)
We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling ...
2010-01-20
International Nuclear Information System (INIS)
Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from ...
2000-12-01
Digital processing to improve image quality in real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
1985-01-01
Digital processing to improve image quality in real-time neutron radiography
International Nuclear Information System (INIS)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
1985-01-01
The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images
Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes in the derived parameters within the ...
2007-01-01
Simulations of dual morphology in spiral galaxies
Gas and stars in spiral galaxies are modelled with the DUAL code, using hydrodynamic and N-body techniques. The simulations reveal morphological differences mirroring the dual morphologies seen in B and K' band observations of many spiral galaxies. In particular, the gaseous images are more flocculent with lower pitch angles than the stellar images, and the stellar arm-interarm contrast correlates with the degree of morphological decoupling.
2003-01-01
Real time neutron radiography using a Lixi neutron imaging device
Energy Technology Data Exchange (ETDEWEB)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or ...
1986-01-15
Real time neutron radiography using a Lixi neutron imaging device
International Nuclear Information System (INIS)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or ...
1986-01-01
Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera
We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.
2009-01-01
Neutron radiography with the cyclotron, 6
International Nuclear Information System (INIS)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
1988-01-01
Impact of computers in radiography: the advent of digital radiography, part-2
International Nuclear Information System (INIS)
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
2008-08-01
In situ scanning tunneling microscope study of the passivation of Cu(111)
Energy Technology Data Exchange (ETDEWEB)
In situ scanning tunneling microscopy has been used to study the nucleation and growth mechanisms and the structure of passive films formed on Cu(111) surfaces in 0.1 M borate buffer solution (pH 9.3). A surface topography characterized by terraces with monoatomic steps is obtained after potentiodynamic reduction down to {minus}1.12 V/standard hydrogen electrode (SHE), of the electropolished surface exposed to air. The formation of a single Cu{sub 2}O passive layer at 0.03 V/SHE proceeds first by a roughening of the steps assigned to a locally blocked step flow process due to a competition between dissolution and preferential nucleation of the oxide at the steps. The observed oxide nuclei are 2--3 nm wide and about one atomic plane high. This process leads to the complete coverage of the terraces by a grain-like structure of the oxide film. The initial terrace topography is completely altered. Thickening of this oxide layer leads to unstable ...
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
A new band gap profile (exponential profile) for the active layer of the a-SiGe:H single junction cell has been designed and experimentally demonstrated. By computer simulations we show how bending the grading of the band gap in the i-layer contributes to the enhancement of the carrier collection, improving the fill factor and efficiency. The differences observed between experiments and simulations are studied using Rutherford Backscattering Spectrometry (RBS). The results highlight weak points during the deposition process, whose control enables us to bring together experimental and computational results.
2004-01-25
IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT
British Library Electronic Table of Contents (United Kingdom)
Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.
2011-01-01
CR portal imaging; A linac graphy using storage phosphor imaging systems
Energy Technology Data Exchange (ETDEWEB)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...
1992-07-01
The potential of multidiurnal MODIS thermal band data for coal fire detection
British Library Electronic Table of Contents (United Kingdom)
In this paper we present the results of our analyses of multidiurnal low-resolution Moderate Resolution Imaging Spectroradiometer (MODIS) thermal data for coal fire-related thermal anomaly detection. Results are presented for data of the Jharia coal mining region of India. We combine three relatively new approaches: first, we use low-resolution MODIS data for coal fire area analyses, which has only been undertaken by a few authors. Second, we analyse data from four different times of day (morning, afternoon, evening and predawn) and for three different bands (MODIS bands 20, 32 and a ratio thereof); and third, we use an unbiased automated algorithm for thermal anomaly extraction of local thermal anomalies. The MODIS data analysed stem from the years 2001 and 2005. In 2001, MODIS data were ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.
1980-02-01
Signal and imaging sciences workshop proceedings
Energy Technology Data Exchange (ETDEWEB)
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
1997-11-01
DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics
... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....
High-resolution beta imaging; L'imagerie beta haute resolution
Energy Technology Data Exchange (ETDEWEB)
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and ...
2007-04-15
International Nuclear Information System (INIS)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...
1992-01-01
MRI findings of the brain in high-voltage electrical burn patient: case report
Energy Technology Data Exchange (ETDEWEB)
We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.
2003-05-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety ...
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety ...
1991-01-01
Enhanced Algorithms for EO/IR Electronic Stabilization, Clutter ...
... coordinates to allow for multisensor fusion, trajectory ... of an image processing toolkit (iPTK ... effectiveness of data-driven registration processing, spatial ...
2009-09-01
International Nuclear Information System (INIS)
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
1996-07-01
British Library Electronic Table of Contents (United Kingdom)
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
2009-01-01
Intense luminescence from porous ZnSe layers
International Nuclear Information System (INIS)
We report on the possibility to prepare ZnSe porous layers with different degrees of porosity by means of electrochemical methods. The prepared porous structures were characterized using scanning electron microscopy (SEM), photoluminescence (PL) and cathodoluminescence (CL) techniques. The PL of the as-grown material and porous layers measured at low temperatures (10 K) was found to be dominated by an emission band at 2.796 eV as well as a band at 2.700 eV with several phonon replicas. The analysis of the dependence of these bands upon the excitation power density and temperature suggests that free-to-bound and respectively donor-acceptor electron transitions are responsible for the emission bands involved. The comparison of SEM and CL images taken from the same porous regions demonstrated that cathodoluminescence intensity from layers with small characteristic sizes of the porous ...
Energy Technology Data Exchange (ETDEWEB)
In the presented case study CRS processing was able to improve the overall data quality of the processed lines in terms of signal-to-noise ratio and imaging. The complex geology is causing serious problems in conventional NMO/DMO processing that were solved by CRS processing. Even a depth processing with velocities calculated from CRS attributes gives good results similar to those from PreSDM in terms of the velocity field. Data quality of poststack depth migrated CRS stacks is even better than the image from PreSDM. (orig.)
2004-07-01
Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive ...
2003-01-01
UK PubMed Central (United Kingdom)
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
2009-06-13
Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy
UK PubMed Central (United Kingdom)
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
2009-01-01
A Software System for Data Analysis in Automated DNA?Sequencing
UK PubMed Central (United Kingdom)
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
1998-06-01
BULGE n AND B/T IN HIGH-MASS GALAXIES: CONSTRAINTS ON THE ORIGIN OF BULGES IN HIERARCHICAL MODELS
International Nuclear Information System (INIS)
We use the bulge Sersic index n and bulge-to-total mass ratio (B/T) to explore the fundamental question of how bulges form. We perform two-dimensional bulge-disk-bar decomposition on H-band images of 143 bright, high-mass (M _* #>=# 1.0 x 10"1"0 M _s_u_n) low-to-moderately inclined (i < 70"0) spirals. Our results are as follows. (1) Our H-band bar fraction (#approx#58%) is consistent with that from ellipse fits. (2) 70% of the stellar mass is in disks, 10% in bars, and 20% in bulges. (3) A large fraction (#approx#69%) of bright spirals have B/T#<=# 0.2, and #approx#76% have low n #<=# 2 bulges. These bulges exist in barred and unbarred galaxies across a wide range of Hubble types. (4) About 65% (68%) of bright spirals with n #<=# 2 (B/T #<=# 0.2) bulges host bars, suggesting a possible link between bars and bulges. (5) We compare the results with predictions from a set of #LAMBDA#CDM models. In the models, ...
2009-05-01
Luminescence Properties of ScPO{sub 4} Single Crystals
Energy Technology Data Exchange (ETDEWEB)
Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high ...
1999-08-16
Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.
Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the ...
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
In this paper, the multisource geoscientific data, such as TM data, NOAA data, the data of Bouguer gravity anomaly and aeromagnetic anomaly, the multisource geophysical processing methods, such as upward continuations, vertical derivative and gradient image, and synthetic image processing method - remote sensing image processing and geophysical image processing under I{sup 2}S600, are used to study the reverse faults or thrusts in the southern margin of Ordos basin, China. On the basis of these results and with geological investigation in the field, the authors have determined three thrust compression systems, named EW thrust compression system, NE thrust compression system and NW thrust compression system. These three systems reveal the regularity of geological structural evolution in the southern margin of Ordos basis ...
1996-08-01
Fundamental concepts of digital image processing
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) ...
1983-03-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, ...
2004-04-01
Optimization of band gap of photonic crystals fabricated by holographic lithography
Generally the photonic band gap (PBG) is a multi-variable function of several parameters related to the shape and size of the dielectric columns of photonic crystals (PhCs), and a time-consuming step-by-step scanning process for each parameter has to be used to find their best combination yielding maximum PBG. In this letter, the widely used Nelder-Mead simplex algorithm is introduced to optimize these parameters simultaneously to find a larger PBG for a new kind of two-dimensional (2D) hexagonal GaAs-Air PhC. This structure can be conveniently produced by the single-exposure holographic lithography, and the specific holographic design is also systematically investigated. This study reveals that the band gaps of PhCs made by holographic lithography may be widened by introducing irregularity of the columns and lowering the symmetry of the structure.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength ...
2009-11-15
COBE confounds the cosmologists
Energy Technology Data Exchange (ETDEWEB)
The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.
1990-03-01
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-06-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-11-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
International Nuclear Information System (INIS)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-01-01
Principium research of real-time neutron radiography in No. 300 reactor
International Nuclear Information System (INIS)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
2002-12-01
International Nuclear Information System (INIS)
The effects of hydrostatic pressure on the electronic band structure of the semiconductor mineral iron pyrite FeS_2 have been investigated theoretically by an ab initio full-potential linearized-augmented plane wave (FPLAPW) method within a local approximation (LDA/GGA) to the density functional theory. The calculations predict that at a pressure of 94.1 GPa the indirect band gap of pyrite FeS_2 vanishes and the material becomes a metal. This is due to the presence of the S-S and Fe-S bonds, which provide novel energy band distortions in the process of attaining the metallic state. Analysis indicates that, under increasing high pressure, the conduction bands (3p_z of sulfur and 3d_x_"2_-_y_"2+3d_x_y of iron) intrude downwards into the valence bands, which are predominantly 3d in nature. At normal pressure, the lattice constant, the bulk modulus, sulfur position ...
2006-10-11
Hard X-ray identification of Eta Carinae and steadiness close to periastron
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), would produce more ...
2010-01-01
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. ...
1996-01-01
Neutron imaging system for neutron tomography, radiography, and beam diagnostics
Energy Technology Data Exchange (ETDEWEB)
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
1995-12-31
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost ...
1994-08-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
International Nuclear Information System (INIS)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost ...
1994-01-01
Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging
International Nuclear Information System (INIS)
Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...
Tolerance limits of X-ray image intensity
International Nuclear Information System (INIS)
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
International Nuclear Information System (INIS)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-01
Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory
International Nuclear Information System (INIS)
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
2006-08-01
Demonstration of a wide-band compact free electron laser to the THZ imaging of bio samples
International Nuclear Information System (INIS)
We have developed a compact terahertz (THz) free electron laser (FEL). The FEL operates in the wavelength range of 100-1200 #mu#m, which corresponds to 0.3-3 THz. THz radiation from the FEL shows much higher power of 100 W compared to the power level, <100 mW, of the table-top sources by conventional lasers. The THz FEL beam shows good performance in pulse-energy stability, polarization, spectrum and spatial distribution. The main application of the FEL is THz imaging for bio-medical researches. We demonstrated the THz imaging of bugs for living condition at 3 THz. The bugs were died just before experiments, so they were not dried. We could get transmitted information through the samples by using the THz FEL beam. In this paper, we will estimate and discuss the required power level of the THz source for the practical application of the imaging.
2007-05-21
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
2010-01-01
Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728
International Nuclear Information System (INIS)
This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional ...
1994-02-01
Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo
Energy Technology Data Exchange (ETDEWEB)
Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early ...
2008-12-15
Liquid metal flow measurement by neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
1996-07-21
Liquid metal flow measurement by neutron radiography
International Nuclear Information System (INIS)
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
1996-07-01
ISR; A database for symbolic processing in computer vision
Energy Technology Data Exchange (ETDEWEB)
Computer vision imposes unique requirements on the representation and manipulation of image data and knowledge. At a vision system's lowest level are sensors that represent an image with purely numeric image arrays, while at the highest level are semantic world models that provide the final interpretation of the scene. In between are thousands of intermediate descriptions, many of which must be repeatedly accessed and processed during interpretation. In this article, the authors describe a representation and management system for use at the intermediate (symbolic) level of vision. Based on database management methodology, the intermediate symbolic representation (ISR) mediates access to intermediate-level vision data and forms an active interface to the higher-level inference processes that construct an image's interpretation. The system ...
1989-12-01
Quantitative metallography is often used to confirm the proper processing of aerospace metallic materials. A microstructural feature of great importance for titanium alloys processed in the alpha-beta phase field is the volume fraction of primary alpha. S...
2006-01-01
Evaluation of the chest radiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.
1991-12-01
Quantitative imaging of turbulent and reacting flows
Energy Technology Data Exchange (ETDEWEB)
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, ...
1993-12-01
Direct digital radiography vs conventional radiography of thoracic spine: a comparative study
International Nuclear Information System (INIS)
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. ...
2005-09-01
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 ...
1983-09-15
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 ...
1983-09-01
A computer-assisted method for 3D subtraction angiography based on spiral CT
International Nuclear Information System (INIS)
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of ...
The utility of recording Raman spectroscopy under liquid nitrogen, a technique we call Raman Under Nitrogen (RUN), is demonstrated for ferrocene, uranocene and thorocene. Using RUN, low temperature (liquid nitrogen cooled) Raman spectra for these compounds exhibit higher resolution than previous studies and new vibrational features are reported. The first Raman spectra of crystalline uranocene at 77 K are reported using excitation from argon (5145 ) and krypton (6764 ) ion lasers. The spectra obtained showed bands corresponding to vibrational transitions at 212, 236, 259, 379, 753, 897, 1500, and 3042 cm-1 , assigned to ring-metal-ring stretching, ring-metal tilting, out-of-plane CCC bending, in-plane CCC bending, ring-breathing, C-H bending, CC stretching and CH stretching, respectively. The assigned vibrational bands are compared to those of uranocene in THF and thorocene. All vibrational frequencies of the ligands, except the 259 cm-1 ...
2004-02-08
International Nuclear Information System (INIS)
The utility of recording Raman spectroscopy under liquid nitrogen, a technique we call Raman Under Nitrogen (RUN), is demonstrated for ferrocene, uranocene and thorocene. Using RUN, low temperature (liquid nitrogen cooled) Raman spectra for these compounds exhibit higher resolution than previous studies and new vibrational features are reported. The first Raman spectra of crystalline uranocene at 77 K are reported using excitation from argon (5145 ) and krypton (6764 ) ion lasers. The spectra obtained showed bands corresponding to vibrational transitions at 212, 236, 259, 379, 753, 897, 1500, and 3042 cm-1 , assigned to ring-metal-ring stretching, ring-metal tilting, out-of-plane CCC bending, in-plane CCC bending, ring-breathing, C-H bending, CC stretching and CH stretching, respectively. The assigned vibrational bands are compared to those of uranocene in THF and thorocene. All vibrational frequencies of the ligands, except the 259 cm-1 ...
2004-02-08
Energy Technology Data Exchange (ETDEWEB)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
1984-09-01
International Nuclear Information System (INIS)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
1984-01-01
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done ...
2011-05-12
Energy Technology Data Exchange (ETDEWEB)
VSP reverse-time migration is a well adaptable wave equation migration method. Its control equation not only describes all-direction propagation of seismic wave but also removes interbed multiples. Clearbout's image principle is generalized to determine image conditions, real VSP data are used to determine boundary condition, and two way reflection-free wave equation is solved by making reverse-time extrapolation. In each step of extrapolation, the migration value at relevant image point is obtained by using the image condition. The complete migration of a seismic section is achieved when reverse-time extrapolation reaches the minimum image time. In this paper it is proved theoretically and practically that this method is applicable to any velocity variation and makes the migrated section have both good resolution and high S/N ratio. Besides, this method results in high ...
1991-01-01
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework ...
2010-01-01
Camera position estimation and feature extraction from an incomplete image of a landmark
British Library Electronic Table of Contents (United Kingdom)
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...
1989-08-01
Pulmonary nodule detection of chest phantom with CRT images
International Nuclear Information System (INIS)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...
1989-01-01
Multimodal MRI assessment of damage and plasticity caused by status epilepticus in the rat brain
British Library Electronic Table of Contents (United Kingdom)
Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.
2011-01-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-01-01
Computer vision algorithms in DNA ploidy image analysis
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation ...
2006-03-01
The Eighth Data Release of the Sloan Digital Sky Survey: First Data from SDSS-III
Energy Technology Data Exchange (ETDEWEB)
The Sloan Digital Sky Survey (SDSS) started a new phase in August 2008, with new instrumentation and new surveys focused on Galactic structure and chemical evolution, measurements of the baryon oscillation feature in the clustering of galaxies and the quasar Ly{alpha} forest, and a radial velocity search for planets around {approx}8000 stars. This paper describes the first data release of SDSS-III (and the eighth counting from the beginning of the SDSS). The release includes 5-band imaging of roughly 5200 deg{sup 2} in the Southern Galactic Cap, bringing the total footprint of the SDSS imaging to 14,555 deg{sup 2}, or over a third of the Celestial Sphere. All the imaging data have been reprocessed with an improved sky-subtraction algorithm and a final, self-consistent recalibration and flat-field determination. This release also includes all data from the second phase of the Sloan Extension for Galactic ...
2011-01-01
We review results from general relativistic axisymmetric magnetohydrodynamic simulations of accretion in Sgr A*. We use general relativistic radiative transfer methods and to produce a broad band (from millimeter to gamma-rays) spectrum. Using a ray tracing scheme we also model images of Sgr A* and compare the size of image to the VLBI observations at 230 GHz. We perform a parameter survey and study radiative properties of the flow models for various black hole spins, ion to electron temperature ratios, and inclinations. We scale our models to reconstruct the flux and the spectral slope around 230 GHz. The combination of Monte Carlo spectral energy distribution calculations and 230 GHz image modeling constrains the parameter space of the numerical models. Our models suggest rather high black hole spin ($a_*\\approx 0.9$), electron temperatures close to the ion temperature ($T_i/T_e \\sim 3$) and high ...
2010-01-01
Medical image transmission via communication satellite. Evaluation of bone scintigraphy
International Nuclear Information System (INIS)
As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and ...
The Infrared Camera (IRC) for the ASTRO-F infrared astronomical satellite
The Infrared Camera (IRC) is one of the scientific focal plane instruments on board the ASTRO-F infrared astronomical satellite. The IRC is designed for wide field imaging and slit-less spectroscopic observations at near- and mid-infrared wavelengths. The IRC consists of three channels; NIR, MIR-S and MIR-L, each of which covers wavelengths of 2-5, 5-12 and 12-26 micron, respectively. All channels adopt compact refractive optical designs. Large format array detectors (a InSb 512 x 412 array and two Si:As IBC 256 x 256 arrays) are employed. Each channel has 10 x 10 arcminutes wide FOV with diffraction-limited angular resolution of 70cm aperture of the liquid helium cooled telescope at wavelengths over 5 micron. A 6-position filter wheel is placed at the aperture stop in each channel, and has three band-pass filters, two grisms/prisms and a mask for dark current measurements. The 5 sigma sensitivity of one pointed observation is estimated to be ...
2004-01-01
Need for New Optimisation Strategies in CR and Direct Digital Radiography
Energy Technology Data Exchange (ETDEWEB)
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to ...
2000-07-01
Need for New Optimisation Strategies in CR and Direct Digital Radiography
International Nuclear Information System (INIS)
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to ...
1999-06-13
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...
2009-12-01
International Nuclear Information System (INIS)
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...
2009-12-01
Interface-induced conversion of infrared to visible light at semiconductor interfaces
International Nuclear Information System (INIS)
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.
Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems
Energy Technology Data Exchange (ETDEWEB)
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
2006-03-06
Creation and filling of thermoluminescence traps during irradiation
Energy Technology Data Exchange (ETDEWEB)
A mathematical model has been constructed to describe the creation and filling of thermoluminescence traps during irradiation. Processes considered include trap filling, recombinations both between free charges and between free and trapped charges and thermal de-trapping. Also a simple trap creation term, linear with dose, has been included. A computer program has been written in order to solve the system of differential equations describing the various charge carrier flows during irradiation. The model and the program are described and the results of the application of the model to some simple energy-level schemes are discussed. Thermal de-trapping and band-to-band recombinations can introduce a dose rate dependence into the accumulation of trapped charge, whilst trap creation leads to the supralinear growth of charge trapped at certain defects with increasing dose.
1986-01-01
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-01-01
Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo
Energy Technology Data Exchange (ETDEWEB)
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital ...
1998-10-01
Neutron radiography with the cyclotron, 5
International Nuclear Information System (INIS)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
1987-01-01
MTF analysis of the near-real time neutron radiography facility at MURR
International Nuclear Information System (INIS)
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
1981-12-01
Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility
Energy Technology Data Exchange (ETDEWEB)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
1999-11-14
Clinical magnetic resonance imaging with nuclear medicine correlation
Energy Technology Data Exchange (ETDEWEB)
The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.
1985-08-01
We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss 20 dB and insertion loss < 0.3 dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 {sup o}C, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO{sub 4}{sup 2-} groups and the PL spectra showed the WO{sub 4}{sup 2-} wide excitation band, broad emission band of WO{sub 4}{sup 2-} and characteristic emissions of Ln{sup 3+} ions. The average particle sizes were determined by TEM, which are about 50 nm.
2010-11-15
International Nuclear Information System (INIS)
The CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 "oC, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO_4"2"- groups and the PL spectra showed the WO_4"2"- wide excitation band, broad emission band of WO_4"2"- and characteristic emissions of Ln"3"+ ions. The average particle sizes were determined by TEM, which are about 50 nm.
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
Electronic properties of passive films formed on Fe at various applied potentials in pH 8.5 buffer solution were examined through the photocurrent measurement and impedance spectroscopy. Passive film formed on Fe at relatively low potentials was found to be r-FeOOH layer and internal r-Fe{sub 2}O{sub 3} layer. However, the r-FeOOH layer became unstable and disappeared at potentials below 400mV and hence may be an adsorbed layer. An electronic band structure model for the passive film of Fe was suggested on the basis of the spinel band model with involving two types of electronic excitation processes, i. e., the p-d and the d-d transition together. The effects of applied potential on the photocurrent behaviors of the passive film on Fe were explained appropriately by separating the photocurrent spectra depending on the transition type. The Mott-Schottky behavior for the passive film on Fe and the photocurrent variation with ...
1999-04-01
Dynamic nucleation of new grains in magnesium alloy during hot deformation
Energy Technology Data Exchange (ETDEWEB)
Microstructure evolution under hot deformation was investigated in compression of a magnesium alloy AZ31 at 673 K (0.73T{sub m}). Two kinds of samples were machined along the parallel and transverse direction of the extruded rods. New fine grains are evolved at corrugated grain boundaries at low strains and developed rapidly in grain interiors in the medium range of strain, finally leading to a roughly full evolution of equiaxial fine grains. Kink bands are evolved at corrugated grain boundaries and in grain interiors at low strains. The boundary misorientation of kink band increases rapidly with increasing strain. These characteristics of new grain evolution process are not changed by the orientation of the samples, while the flow behaviors clearly depend on it. It is concluded that new grain evolution can be controlled by a deformation-induced continuous reaction resulting in grain fragmentation by kink ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
A silicon capacitive accelerometer was fabricated to detect subsurface elastic waves by using micromachining technology. Characteristics required for it call for capability of detecting acceleration with amplitudes from 0.1 to 1 gal and flat amplitude characteristics in frequency bands of 10 Hz to several kHz. For the purpose of measuring transition phenomena, linear phase characteristics in the required bands must be guaranteed, cross sensitivity must be small, and resistance to water, pressure and heat is demanded. Sensitivity of the sensor is determined finally by noise level in a detection circuit. The sensor`s minimum detection capability was 40 mgal in the case of the distance between a weight and an electrode being 3 {mu}m. This specification value is a value realizable by the current micromachining technology. Dimensions for the weight and other members were decided with the natural frequency to make band width 2 ...
1997-05-27
Subcellular distribution of ryanodine receptors in the cardiac muscle of carp (Cyprinus carpio).
We examined the subcellular localization of ryanodine receptors (RyR) in the cardiac muscle of carp using biochemical, immunohistochemical, and electron microscopic methods and compared it with those of rats and guinea pigs. To achieve this goal, an anti-RyR antibody was newly raised against a synthetic peptide corresponding to an amino acid sequence that was conserved among all sequenced RyRs. Western blot analysis using this antibody detected a single RyR band following the SDS-PAGE of sarcoplasmic reticulum (SR) membranes from carp atrium and ventricle as well as from mammalian hearts and skeletal muscles. The carp heart band had slightly greater mobility than those of mammalian hearts. Although immunohistochemical staining showed evident striations corresponding to the Z lines in longitudinal sections of mammalian hearts, clusters of punctate staining, in contrast, were distributed ubiquitously throughout carp atrium and ventricle. Electron ...
2003-06-12
Spectral characteristics of lignite open cast mining systems: a preliminary status
Energy Technology Data Exchange (ETDEWEB)
The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.
1999-07-01
Practical MRI atlas of neonatal brain development
International Nuclear Information System (INIS)
This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.
Pharmaceutics | Special Issue: Molecular Imaging
...) Abstract: Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated strategies that have been developed for selectively labeling target molecules. More recently, two and ...
Model of quantum noise of shadow radiation images
International Nuclear Information System (INIS)
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Characterization of Adaptive Optics at Keck Observatory
Energy Technology Data Exchange (ETDEWEB)
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
2003-07-24
An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy
Energy Technology Data Exchange (ETDEWEB)
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
1991-12-01
International Nuclear Information System (INIS)
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI ...
2010-11-21
A high-sensitivity small animal SPECT system
International Nuclear Information System (INIS)
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo ...
2009-03-07
Microstructures of friction welded joints of AZ31 to AM60 magnesium alloys
Energy Technology Data Exchange (ETDEWEB)
AZ31 magnesium alloy was friction-welded to AM60 and the microstructures and the friction welding process were studied. The microstructures changed near the weld interface. The AZ31 was refined to a grain size of several {mu}m near the weld interface. The nucleation occurred in the shear bands that were introduced during the welding process. On the other hand, the eutectic structure was deformed and the lamellar structure which was composed of {alpha}-Mg and Mg{sub 17}Al{sub 12} was formed near the weld interface in AM60 alloy. In the friction process, the adhesion and peel off occurred alternately between AZ31 and AM60. Eventually, bonding was completed during upset process. (orig.)
2003-07-01
British Library Electronic Table of Contents (United Kingdom)
Orthogonal frequency division multiplexing (OFDM) can fully use the frequency band and transmit data at high speeds. The ADSP-TS101 is a high performance digital signal processor (DSP) with good properties that include parallel processing and a high speed. Aimed at the real-time processing requirement of the OFDM algorithm, an underwater acoustic communication system with real-time processing capability is carried out. The system is mainly composed of multiple ADSP-TS101s, a multi-channel synchronous sample module and a field programmable gate array (FPGA) chip. The multiprocessor structure is made up of a cluster/data flow associated multiprocessing parallel processing structure as the operation kernel, and a multi-channel synchronous sample module is designed to realize no phase warp amo...
2007-01-01
Single chip linear array picture processor
Energy Technology Data Exchange (ETDEWEB)
A CMOS programmable picture processor with its own photodiode array is presented. The circuit is novel in that it includes an instruction set that permits most low-level picture processing operations. The chip is a parallel machine with a processing unit for each picture element. Images are binarized and are processed line by line. An experimental chip has been designed and is under fabrication. 2 references.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR ...
2001-03-01
In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging
UK PubMed Central (United Kingdom)
Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available
2008-03-01
Imaging Findings of Localized Lymphoid Hyperplasia of the Pancreas: a Case Report
UK PubMed Central (United Kingdom)
We report here on a case of localized lymphoid hyperplasia of the pancreas in a 70-year-old man which manifested as double lesions (uncinate process and tail) in the organ. The lesions were incidentally...Full Text Available
2011-07-01
EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS
UK PubMed Central (United Kingdom)
In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available
2007-05-15
Colour television, an imitation of the human visual system.
UK PubMed Central (United Kingdom)
Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available
1975-07-01
A caGRID-ENABLED, LEARNING BASED IMAGE SEGMENTATION METHOD FOR HISTOPATHOLOGY SPECIMENS
UK PubMed Central (United Kingdom)
Accurate segmentation of tissue microarrays is a challenging topic because of some of the similarities exhibited by normal tissue and tumor regions. Processing speed is another consideration...Full Text Available
2009-07-01
Multidate image analysis of forest degradation in equatorial Africa
Energy Technology Data Exchange (ETDEWEB)
A section of the northern margin of the Guineo-Congolian rain forest of the Central African Republic is studied to determine to what extent deforestation is evolving. Three sites are presented to highlight the diversity in local environmental settings at the northern margin of the closed equatorial rain forest: the contiguous equatorial rain forest, the boundary between the closed rain forest and the grasslands, and a predominantly secondary grassland environment. Proven image processing procedures for determining land cover and vegetation vigor were applied to Landsat MSS data to determine land cover characteristics and identify alterations in land cover that indicate potentially degraded forest environments. Land cover was independently assessed using spectral signatures determined from a statistical clustering routine. The images presented and image analyses contribute insights and information to an ...
1990-12-01
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation ...
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-15
Groundtruth approach to accurate quantitation of fluorescence microarrays
Energy Technology Data Exchange (ETDEWEB)
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the ...
2000-12-01
International Nuclear Information System (INIS)
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
1983-01-01
Angiography of the head using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
1985-01-01
In vivo magnetic resonance techniques and drug discovery
International Nuclear Information System (INIS)
The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)
2006-03-01
The unusual host galaxy of the BL Lac object PKS 1413+135
The BL Lacertae object PKS 1413+135 is associated with a disk dominated galaxy which heavily absorbs the BL Lac nucleus at optical and X-ray wavelengths. It has been argued whether this galaxy is actually the host galaxy of PKS 1413+135 or whether the BL Lac is a background QSO, gravitationally lensed by the apparent host galaxy. We have obtained deep high resolution H-band images of this unusual BL Lac object using the UKIRT IRCAM3. Our observations show that the BL Lac nucleus is centered within < 0.05 arcsec of the galaxy. Based on this result we assess the probability for the lensing scenario and come to the conclusion that the disk galaxy is indeed the host of PKS 1413+135. The galaxy shows peanut-shaped isophotes, suggesting the presence of a central bar which is a common feature of AGN
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes a 1993 field experiment entitled Marine Aerosol Properties and Thermal Imager Performance Trial (MAPTIP) conducted by NATO AC/243 Panel 04/RSG.8 and 04/RSG.5 in the Dutch coastal waters. Objectives were: to improve and validate vertical marine aerosol models by providing an extensive set of aerosol and meteorological measurements, within a coastal environment at different altitudes and for a range of meteorological conditions; make aerosol and meteorological observations in the first 10 m of the ocean surface with a view to extending existing aerosol models to incorporate near-surface effects; and to assess marine boundary layer effects on thermal Imaging systems. Aerosol and meteorological instruments, as well as thermal imagers and calibrated targets, were utilized. This network of instrumentation has provided a comprehensive database of aerosol size distribution profiles and relevant meteorological ...
1995-08-01
International Nuclear Information System (INIS)
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with ...
2007-02-01
Evaluation of performance and characteristics of neutron radiography and standardization
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the ...
1995-02-01
Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam
International Nuclear Information System (INIS)
Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction ...
1999-05-21
Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment
Energy Technology Data Exchange (ETDEWEB)
Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in ...
2009-01-29
Energy Technology Data Exchange (ETDEWEB)
A theoretical background of crosshole reflection imaging with pre stack, multi-mode reverse time migration has been investigated. The crosshole migration has been carried out by solving two-way scalar wave equation with finite difference approximation. The wave field extrapolation was performed backward in time, with the imaging condition applied at each extrapolation time step to create partial image of the reflector. The complete migrated image was obtained by adding all the partial images from each time step. With multi-component crosshole data available, it is possible to separate the recorded data into primary P- and S-wave field. Separating wave field before migration is helpful in enhancing migrated image quality since only one wave mode can be dealt at a time with the scalar wave equation. It is possible to migrate mixed-mode primary reflections(P-S and ...
1993-08-31
The Star Clusters in the Irregular Galaxy NGC 4449
We examine the star clusters in the irregular galaxy NGC 4449. We use a near-infrared spectrum and broad-band images taken with the HST to place a limit of 8--15 Myrs on the age of the bright central ojbect in NGC 4449. Its luminosity and size suggest that it is comparable to young super star clusters. However, there is a peculiar nucleated-bar structure at the center of this star cluster, and we suggest that this structure is debris from the interaction that has produced the counter-rotating gas systems and extended gas streamers in the galaxy. From the images we identify 60 other candidate compact star clusters in NGC 4449. Fourteen of these could be background elliptical galaxies or old globular star clusters. Of the star clusters, three, in addition to the central object, are potentially super star clusters, and many others are comparable to the populous clusters found in the LMC. The star clusters span a large range in ...
2000-01-01
High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A
Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...
2009-01-01
Visualization and measurement of heat transfer phenomenon
Energy Technology Data Exchange (ETDEWEB)
This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...
1995-03-01
Energy Technology Data Exchange (ETDEWEB)
To keep up with the speeds of modern production lines, most machine vision applications require very powerful computers (often parallel-processing machines), which process millions of points of data in real time. The human brain performs approximately 100 billion logical floating-point operations each second. That is 400 times the speed of a Cray-1 supercomputer. The right software must be developed for parallel-processing computers. The NSF has awarded Rensselaer Polytechnic Institute (Troy, N.Y.) a $2 million grant for parallel- and image-processing software research. Over the last 15 years, Rensselaer has been conducting image-processing research, including work with high-definition TV (HDTV) and image coding and understanding. A similar NSF grant has been awarded to Michigan State University (East Lansing, Mich.) Neural networks are supposed to emulate human ...
1989-06-01
Energy Technology Data Exchange (ETDEWEB)
The coherent interaction of femtosecond laser pulses and a thin CdSe sample is investigated both experimentally and theoretically. Observation of coherent phenomena in semiconductors is very rare because the incoherent processes occur in the femtosecond time domain in these materials. One example of such a phenomena is the so called optical Stark effect of exciton where a blue shift of the exciton resonance occurs as a result of pumping below the bandgap. The coherent effects involving band-to-band and also exciton transitions. Using femtosecond transmission measurements clear evidence was observed for coherent interference effects of the light field and the driven material polarization. These interferences manifest themselves as oscillatory structures in the differential transmission spectra. The oscillatory features are explained by comparison with a semiclassical theory. Examples of the computed results are presented for different time ...
1987-01-01
ALOS satellite imagery utilizations for safeguards
International Nuclear Information System (INIS)
This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 ...
2006-10-16
BackgroundIn recent years, near-infrared fluorescence (NIRF)-labeled iron nanoparticles have been synthesized and applied in a number of applications, including the labeling of human cells for monitoring the engraftment process, imaging tumors, sensoring the in vivo molecular environment surrounding nanoparticles and tracing their in vivo biodistribution. These studies demonstrate that NIRF-labeled iron nanoparticles provide an efficient probe for cell labeling. Furthermore, the in vivo imaging studies show excellent performance of the NIR fluorophores. However, there is a limited selection of NIRF-labeled iron nanoparticles with an optimal wavelength for imaging around 800 nm, where tissue autofluorescence is minimal. Therefore, it is necessary to develop additional alternative NIRF-labeled iron nanoparticles for application in this area.ResultsThis study manufactured 12-nm DMSA-coated Fe3O4 ...
2010-10-29
With the help of self-assembly, thermal sintering, selective etching techniques and sol-gel process, the non-close packed (ncp) face-centered cubic (fcc) photonic crystals of titanium dioxide (TiO2) hollow spheres connected by TiO2 cylindrical tubes have been fabricated using silica template. The photonic bandgap calculations indicate that the ncp structure of TiO2 hollow spheres was easier to open the pseudogaps than close packed system at the lowest energy. PMID:17097102
2006-10-21
International Nuclear Information System (INIS)
Currentless plasma in Uragan-3M (U-3M) is produced and heated by absorption of RF power in the region of Alfven waves (AW). The process of plasma heating was explained in (2) as a result of Cherenkov absorption of energy of the fast (EM) and slow (kinetic Alfven) waves by electrons and turbulent ion heating due to excitation of short wave ion Bernstein waves (IBW). In this report we present results of studies of plasma density fluctuations showing existence of a narrow bands near the frequencies of ? ? n?ci (n=1,2,3).
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Acetylacetone is isolated in hydrogen matrices and is investigated by means of infrared spectroscopy, combined with theoretical calculations. The two stable enol and keto tautomers are well characterized. The keto/enol ratio in solid parahydrogen is found to be higher than in classical matrices. While vibrational bands of the enol form are broad, with bandwidths depending on the vibrational mode, those of the keto form are narrow. A KrF laser excitation is used to induce the enol/keto tautomerization in solid parahydrogen. The kinetics of the interconversion is followed, highlighting a non-direct tautomerization process.
2011-01-01
DETECTION OF A PSEUDOBULGE HIDDEN INSIDE THE 'BOX-SHAPED BULGE' OF NGC 4565
International Nuclear Information System (INIS)
Numerical simulations show that box-shaped bulges of edge-on galaxies are not bulges: they are bars seen side-on. Therefore, the two components that are seen in edge-on Sb galaxies such as NGC 4565 are a disk and a bar. But face-on SBb galaxies always show a disk, a bar, and a (pseudo)bulge. Where is the (pseudo)bulge in NGC 4565? We use archival Hubble Space Telescope H-band images and Spitzer Space Telescope 3.6 #mu#m wavelength images, both calibrated to Two Micron All Sky Survey K_s band, to penetrate the prominent dust lane in NGC 4565. We find a high surface brightness, central stellar component that is clearly distinct from the boxy bar and from the disk. Its brightness profile is a Sersic function with index n = 1.55 #+-# 0.07 along the major axis and 1.33 #+-# 0.12 along the minor axis. Therefore, it is a pseudobulge. It is much less luminous than the boxy bar, so the true pseudobulge-to-total ...
2010-06-01
We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the GOODS-South field. The new WFC3 ERS data provide calibrated, drizzled mosaics with FHWM=0.07--0.15" in the near-UV (filters F225W, F275W, and F336W) and near-IR (F098W, F125W, and F160W) in typically 2 orbits per filter. Together with the existing HST/ACS GOODS-S mosaics in the BVi'z' filters, the 10-band ERS data cover 40-50 sq. arcmin to AB=26-27.0 mag (10-sigma for point sources). In this poster, we describe the: (1) scientific rationale, data taking and reduction procedures of the WFC3 ERS mosaics; (2) object cataloging and star-galaxy separation techniques used in these 10 different filters; (3) reliability and completeness of the 10-band object catalogs from the ERS mosaics; (4) object counts in 10 different filters from 0.2-1.7 microns to AB=26.0-27.0 mag; and (5) the full-color 10-band ERS ...
2010-01-01
A novel method to characterize the MTF in 3D for computed mammotomography
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...
2006-03-01
The identical bands in [sup 177]Ta
Energy Technology Data Exchange (ETDEWEB)
The 4025/2 bands in [sup 177]Ta which are ''identical'' to the neighboring even-even [sup 176]Hf groundstate band have been extended to higher angular momentum. These bands in the two nuclei are seen to diverge from each other in the region of the first i[sub 13/2] neutron alignment. The lower observed crossing frequency for the 4025/2 bands indicates a lower deformation for these bands compared to [sup 176]Hf. Extensions to the h[sub 9/2] 5411/2 yrast band are also reported. (orig.)
1993-10-01
The identical bands in "1"7"7Ta
International Nuclear Information System (INIS)
The [402]5/2 bands in "1"7"7Ta which are ''identical'' to the neighboring even-even "1"7"6Hf groundstate band have been extended to higher angular momentum. These bands in the two nuclei are seen to diverge from each other in the region of the first i_1_3_/_2 neutron alignment. The lower observed crossing frequency for the [402]5/2 bands indicates a lower deformation for these bands compared to "1"7"6Hf. Extensions to the h_9_/_2 [541]1/2 yrast band are also reported. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual SAR images shows that ...
2001-10-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear ...
1987-01-01
Neutron radiography with the cyclotron, 4
International Nuclear Information System (INIS)
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution ...
1986-01-01
Fast Implementation of Matched Filter Based Automatic Alignment Image Processing
Energy Technology Data Exchange (ETDEWEB)
Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field programmable logic array (FPGA) to speed up these computations. The ...
2008-04-02
International Nuclear Information System (INIS)
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as ...
Rapid Tools for Joint Inversion and Imaging. Final report
Energy Technology Data Exchange (ETDEWEB)
The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.
2000-08-02
Models of cardiac electromechanics based on individual hearts imaging data
British Library Electronic Table of Contents (United Kingdom)
Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...
2011-01-01
Lung cancer screening program using annual chest radiographs with computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.
1987-08-01
Lung cancer screening program using annual chest radiographs with computed radiography (FCR)
International Nuclear Information System (INIS)
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).
1987-01-01
FCR (Fuji Computed Radiography) in neurosurgery
Energy Technology Data Exchange (ETDEWEB)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
1988-08-01
FCR (Fuji Computed Radiography) in neurosurgery
International Nuclear Information System (INIS)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
1988-01-01
British Library Electronic Table of Contents (United Kingdom)
Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.
2009-01-01
International Nuclear Information System (INIS)
Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).
1989-10-01
Energy Technology Data Exchange (ETDEWEB)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
1987-03-01
Morphological dilation image coding with context weights prediction
This paper proposes an adaptive morphological dilation image coding with context weights prediction. The new dilation method is not to use fixed models, but to decide whether a coefficient needs to be dilated or not according to the coefficient's predicted significance degree. It includes two key dilation technologies: 1) controlling dilation process with context weights to reduce the output of insignificant coefficients, and 2) using variable-length group test coding with context weights to adjust the coding order and cost as few bits as possible to present the events with large probability. Moreover, we also propose a novel context weight strategy to predict coefficient's significance degree more accurately, which serves for two dilation technologies. Experimental results show that our proposed method outperforms the state of the art image coding algorithms available today.
2010-01-01
Magnetic resonance imaging in joint diseases
International Nuclear Information System (INIS)
Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection ...
Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility
Energy Technology Data Exchange (ETDEWEB)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
1999-07-01
Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU
Energy Technology Data Exchange (ETDEWEB)
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
1992-12-01
Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU
International Nuclear Information System (INIS)
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
1992-01-01
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
Transient-enhanced diffusion during furnace and rapid thermal annealing of ion-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
A transient-enhanced diffusion has been observed during the furnace or rapid thermal annealing of ion-implanted silicon. We have studied this transient in detail and show that, for doses of Group V dopants sufficient to amorphize the silicon, it arises from the trapping of interstitials by dopant atoms during implantation. These are retained during solidphase-epitaxial (SPE) growth, but can be released by additional thermal processing to cause the observed transient and the formation of a band of extended defects. We have measured the enhanced diffusion coefficients and the duration of the transient for Sb-implanted Si by careful furnace annealing experiments. We obtain general expressions which predict the effects of the transient during any thermal processing based on SPE growth (furnace, CW laser, or rapid thermal annealing). We show that there is no analogous mechanism of vacancy trapping by Group III elements.
1985-08-01
Transient-enhanced diffusion during furnace and rapid thermal annealing of ion-implanted silicon
International Nuclear Information System (INIS)
A transient-enhanced diffusion has been observed during the furnace or rapid thermal annealing of ion-implanted silicon. We have studied this transient in detail and show that, for doses of Group V dopants sufficient to amorphize the silicon, it arises from the trapping of interstitials by dopant atoms during implantation. These are retained during solidphase-epitaxial (SPE) growth, but can be released by additional thermal processing to cause the observed transient and the formation of a band of extended defects. We have measured the enhanced diffusion coefficients and the duration of the transient for Sb-implanted Si by careful furnace annealing experiments. We obtain general expressions which predict the effects of the transient during any thermal processing based on SPE growth (furnace, CW laser, or rapid thermal annealing). We show that there is no analogous mechanism of vacancy trapping by Group III elements.
Programmed cell death during pigment gland formation in Gossypium hirsutum leaves
British Library Electronic Table of Contents (United Kingdom)
Abstract Ultrastructural studies have shown that the formation of pigment glands in Gossypium hirsutum L. leaves is a lysigenous process, originating from a cluster of cells in the ground meristem. Various techniques were used here to investigate whether programmed cell death (PCD) plays a critical role in this developmental process. Nuclei of internal cells in the pigment gland-forming tissue were TUNEL-positive and DAPI-negative, suggesting that DNA cleavage is an early event and complete DNA degradation is a late event. Smeared bands and a lack of laddering after gel electrophoresis indicate that DNA cleavage is random. Ultrastructurally, secretory cells in the pigment glands become distorted, nuclei are densely stained, and chromosomes become condensed until completely degraded at late...
2010-01-01
Designed defects in 2D antidot lattices for quantum information processing
DEFF Research Database (Denmark)
We propose a new physical implementation of spin qubits for quantum information processing, namely defect states in antidot lattices defined in the two-dimensional electron gas (2DEG) at a semiconductor heterostructure. Calculations of the band structure of a periodic antidot lattice are presented. A point defect is created by removing a single antidot, and calculations show that localized states form within the defect, with an energy structure which is robust against thermal dephasing. The exchange coupling between two electrons residing in two tunnel-coupled defect states is calculated numerically. We find results reminiscent of double quantum dot structures, indicating that the suggested structure is a feasible physical implementation of spin qubits.
2008-01-01
Real-time neutron radiography at Texas A and M University
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The ...
1990-12-20
Real-time neutron radiography at Texas A and M University
International Nuclear Information System (INIS)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The ...
1990-12-01
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
Energy Technology Data Exchange (ETDEWEB)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup ...
2009-07-01
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
International Nuclear Information System (INIS)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 ...
2009-06-07
Computer simulation and scientific visualization
Energy Technology Data Exchange (ETDEWEB)
The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.
1990-01-01
International Nuclear Information System (INIS)
We report, for the first time to our knowledge, on the active optical planar waveguides in Nd : YAG laser crystals fabricated by O3+ ion implantation at low doses of ?1014 ions cm-2. The reconstructed refractive index profiles based on the measured dark-mode spectroscopy show that an enhanced refractive index well is created in the near-surface region, forming a non-leaky waveguide structure. With thermal annealing treatment at 260 0C for 90 min, the propagation losses of the waveguides could be reduced to ?3 dB cm-1 at a wavelength of 632.8 nm. The micro-luminescence investigation reveals that the emission bands of Nd3+ ions are not significantly affected by the waveguide formation processing, which shows promising potentials for efficient waveguide laser operations at near-infrared wavelength bands.
2008-09-07
Laser stabilization at 1536 nm using regenerative spectral hole burning
International Nuclear Information System (INIS)
Laser frequency stabilization giving a 500-Hz Allan deviation for a 2-ms integration time with drift reduced to 7 kHz/min over several minutes was achieved at 1536 nm in the optical communication band. A continuously regenerated spectral hole in the inhomogeneously broadened "4I_1_5_/_2(1)#->#"4I_1_3_/_2(1) optical absorption of an Er"3"+:Y_2SiO_5 crystal was used as the short-term frequency reference, while a variation on the locking technique allowed simultaneous use of the inhomogeneously broadened absorption line as a long-term reference. The reported frequency stability was achieved without vibration isolation. Spectral hole burning frequency stabilization provides ideal laser sources for high-resolution spectroscopy, real-time optical signal processing, and a range of applications requiring ultra-narrow-band light sources or coherent detection; the time scale for stability and the compatibility with spectral hole ...
2001-04-15
Interface-induced conversion of infrared to visible light at semiconductor interfaces
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al{sub {ital x}}Ga{sub 1{minus}{ital x}}InP{sub 2}; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. {copyright} {ital 1996 The American Physical Society.}
1996-08-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was not detected, most ...
2004-12-21
Energy Technology Data Exchange (ETDEWEB)
Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring spot sizes close to 3 nm, understanding and developing RF-BPMs will be essential in ...
1998-08-01
Atlas of nuclear medicine imaging
Energy Technology Data Exchange (ETDEWEB)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
1981-01-01
Representation of uncertainty in computer vision using fuzzy sets
Energy Technology Data Exchange (ETDEWEB)
Uncertainty in computer vision can arise at various levels. It can occur in the low level in the raw sensor input, and extends all the way through intermediate and higher levels. Ideally, at any level where decisions are being made on the basis of previous processing steps, a computer vision system must have sufficient flexibility for representation of uncertainty in any of these levels. The input cue representation portion of a computer vision system should maintain the information content of the original input images, while at the same time allowing for uncertainty in the identification of attributes required by other parts of the system for decision making. Processes such as edge detection, segmentation, and shape matching yield results which could bias higher level decision making, unless some framework is defined for the representation of uncertainty in the context of fuzzy set theory where membership values associated ...
1986-02-01
System Design and Applications of the Ultra Small ... - GLTRS - NASA
The advanced technologies of Ka-Band systems such as high gain spot .... sometimes used based on link requirements for a specific application. .... received at NASA LeRC from a Ku-band satellite and retransmitted to the USAT at Ka-Band. .... and to the Office of Management and Budget, Paperwork Reduction Project ...
Signature splitting and configuration assignments in three-quasiparticle rotational bands
International Nuclear Information System (INIS)
There are 173 three quasiparticle rotational bands, out of which 38 bands display signature splitting and sometimes a signature inversion also. The observed signature splitting is basically due to the higher order Coriolis coupling and calculation based on particle rotor model (PRM) are in progress
2003-12-01
International Nuclear Information System (INIS)
Tris(8-quinolinolato)aluminum(III) (Alq3) shows electronic absorption bands at 378, 360 (in a 1:1 mixed solvent of methanol and ethanol (ME) at 77 K), 334, 316, 300, 263, 255.8, and 233 nm in ethanol at room temperature. According to the polarized fluorescence excitation spectrum together with MO calculations, for instance, the 360 nm band is assigned to an LL CT transition (an intramolecular charge transfer transition between two ligands), and the 378 nm band to an LM/ML CT one (an intramolecular charge transfer transition between ligand and metal). Alq3 shows a broad fluorescence band peaking at around 478 nm in the ME matrix at 77 K. The emission spectrum measured with a phosphoroscope has two emission bands at 567 and 478 nm. The 567 nm band accompanies vibronic bands at 578 and 605 nm, being safely assigned to a phosphorescence of Alq3. ...
2008-08-01
Satellite remote sensing of Spratly Islands using SAR
British Library Electronic Table of Contents (United Kingdom)
Spratly Islands, located in the southern part of the South China Sea (SCS), consist of more than 100 small islands, coral reefs and banks. Remote sensing is the only way to obtain a synoptic view of all of the islands in such a large area. It has been demonstrated that satellite synthetic aperture radar (SAR) imagery is a very powerful tool for monitoring meso-scale and small-scale ocean processes in a large area. In this study, satellite SAR images were used to study the ocean environment in the area of Spratly Islands. The aim was to understand the capability of satellite remote sensing to monitor ocean processes and provide information for future field studies. Two sets of high-resolution European Remote Sensing satellite (ERS)-2 SAR images over the entire Spratly Islands area were coll...
2008-01-01
Measurement of dynamic fracture toughness and failure behavior for explosive mock materials
British Library Electronic Table of Contents (United Kingdom)
In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digital images were processed using the digital image correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.
2011-01-01
np-nh bands in the N=28 isotones
The existence of n-particle n-hole deformed yrare bands in the N=28 isotones is explored using full pf-shell diagonalizations and the Lanczos Strength Function method. We find different 2p-2h and 4p-4h collective bands that, when allowed to mix, more often disappear. Only the 2p-2h yrare band in Cr-52 and the 4p-4h yrare band in Ni-56 survive, and only in this latter case, due to the reduced density of 2p-2h states, can the band be seen as a gamma-cascade.
2002-01-01
Effective mass of heavy holes in diamond-like semiconductors
Nonparabolicity of the heavy hole band in diamond-like semiconductors, which occurs within the framework of the three band model with the perturbation from the other bands taken into account according to the Loewdin procedure, is studied. A direct dependence of nonparabolicity on the band anisotropy (caused by the different effect of Gamma/sub 15c/ and Gamma/sub 12c/ bands) and the inverse dependence on the magnitude of the spin-orbit splittiing is established. A connection between the effective mass of heavy holes and their energy is obtained, which is valid for the majority of diamond-like semiconductors, except for materials with a very strong nonparabolicity of the band of silicon type
1987-08-01
Effective mass of heavy holes in diamond-like semiconductors
International Nuclear Information System (INIS)
Nonparabolicity of the heavy hole band in diamond-like semiconductors, which occurs within the framework of the three band model with the perturbation from the other bands taken into account according to the Loewdin procedure, is studied. A direct dependence of nonparabolicity on the band anisotropy (caused by the different effect of Gamma/sub 15c/ and Gamma/sub 12c/ bands) and the inverse dependence on the magnitude of the spin-orbit splittiing is established. A connection between the effective mass of heavy holes and their energy is obtained, which is valid for the majority of diamond-like semiconductors, except for materials with a very strong nonparabolicity of the band of silicon type.
"ID# ","Measurement ID Number " "DATE ","Date " "JDATE ","Julian Date " "TIME ", "Local Time " "GMT ","Greenwich Mean Time " "BAND ","Dielectric Probe Band ...
Space Network Ku-band service. ... Completed GLAST mission schedule and budget assessment .... Utilize Ku band SN link (TDRSS) for science data return ...
Energy Technology Data Exchange (ETDEWEB)
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, ...
1995-08-01
International Nuclear Information System (INIS)
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the ...
1993-06-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the ...
1994-07-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the ...
1993-01-01
The next wave : kaleidoscope project aims to break the sound barrier of seismic imaging
Energy Technology Data Exchange (ETDEWEB)
This article discussed a project formed to develop innovative seismic imaging technologies. The Kaleidoscope project aims to accelerate the processing of seismic sound waves by several orders of magnitude using advanced computer-based techniques to reveal oil and gas deposits buried deep in the earth in a manner that is both cost-effective and efficient. It is expected that the technology will be used in deep water applications with massive untapped reserves. The seismic technology will be used to locate hydrocarbons and oil reserves buried 20,000 feet beneath the seabed. It is estimated that the Gulf of Mexico contains 56 billion barrels of oil equivalent worth nearly $6 trillion. However, the reserves are difficult to locate due to the interbedded salt bodies in the subsurface. The project is simultaneously working on both hardware and software applications, and are currently writing the first petascale set of seismic ...
2008-05-15
Determination of Inter-Phase Line Tension in Langmuir Films
A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different phases of the steam stimulation process to examine the relation between reservoir ...
1994-12-31
The infrared-dominated jet of 3C401
We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the location of the synchrotron peak in the ...
2005-01-01
The cometary activity of Centaur P/2004 A1 (LONEOS)
British Library Electronic Table of Contents (United Kingdom)
Abstract P/2004 A1 (LONEOS) is one of the few active objects in the dynamical class of Centaurs. It has been recently injected into an inner orbit with a perihelion distance-q-= 5.5 au. The aim of this paper is to characterize the dust coma of this peculiar object, 2.5 yr after its first -new- perihelion passage inside the Solar system. Broad-band visible images taken at the TNG telescope in 2007 February were analysed in order to characterize the dust coma of the Centaur: it was still quite active at-rh-= 6.5 au post-perihelion, with a coma and a well-developed wide tail-like structure, with a measured-R-Af= 162 10-cm in an aperture radius = 104 km. The (V---R) colour and the reddening values depict a scenario of a slightly red dust coma. A dust mass-loss rate of--= 133 kg-s-1 is derived ...
2011-01-01
The Magdalena Ridge Observatory 2.4 m Telescope
EOS Technologies has been commissioned to design and build a unique 2.4m astronomical telescope for the Magdalena Ridge Observatory. This telescope utilizes a high quality primary mirror and cell from a now decommissioned military application. This paper describes the project and gives an overview of the telescope design. The Magdalena Ridge Observatory (MRO) 2.4 meter telescope will be primarily utilized to observe, track, and characterize solar system astronomical targets, Earth satellites, space vehicles, and terrestrial military targets. The telescope's rapid tracking (slew rates are 10o/sec) will allow it to move to any target and acquire data within one minute of receipt of notice. In this way, the telescope will be used to capitalize on targets of opportunity that occur in asteroid studies (e.g., Near Earth Objects) and in astrophysics, such as gamma ray bursts and other transient phenomena. Planned instrumentation includes a CCD imager, and a ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements require a linear ...
2004-12-15
Stellar Populations of Lyman-alpha Emitters at z=4.86: A Comparison to $z\\sim5$ LBGs
(abridged) We present a study of stellar population of LAEs at z=4.86 in GOODS-N and its flanking field. With the publicly available IRAC data in GOODS-N and further IRAC observations in the flanking fields, we select five LAEs which are not contaminated by neighboring objects in IRAC images and construct their observed SEDs with I_c, z', IRAC 3.6micron, and 4.5micron band photometry. The SEDs cover the rest-frame UV to optical wavelengths. We derive stellar masses, ages, color excesses, and star formation rates of five LAEs using SED fitting method. Assuming the constant star formation history, we find that the stellar masses range from 10^8 to $10^{10} Msun with the median value of 2.5x10^9 Msun. The derived ages range from very young ages (7.4 Myr) to 437 Myr with a median age of 25 Myr. The color excess E(B-V) are between 0.1-0.4 mag. Star formation rates are 55-209 Msun/yr. A comparison of the stellar populations is made between three LAEs ...
2010-01-01
Spherically bent crystal spectroscopy in laser-produced plasma
International Nuclear Information System (INIS)
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from Al laser-produced ...
2008-02-01
Energy Technology Data Exchange (ETDEWEB)
The standards mapping methods are limited by the lack of information between surface measures and wells profiles. The cross well seismic survey has proven being an effective high-resolution method for reservoirs characterization due its high frequency band. In this work, a 2-D finite differences algorithm for numerical cross well seismic simulation was developed, based in the approach of 2nd order for the time derivatives and 4th order for the space derivatives. In relation to the imaging techniques, it was introduced a reverse time migration method based in the solutions of the wave equation in time for cross well seismic data by the method of the finite differences exclusively. The results of reverse time migration has showed that layers with 90 cm thickness for P-waves could be visualized in migrated sections with excellent resolution. The high frequency cross well seismic data combined with reverse time migration have the potential for ...
2003-07-01
Recent Progress in CdTe and CdZnTe Detectors
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in ...
2001-01-01
Multi-wavelength observations of the young binary system Haro 6-10: The case of misaligned discs
Context. We present a multi-wavelength, high-resolution observational survey of the young binary system Haro 6-10 (GV Tau, IRAS 04263+2426), which is harbouring one of the few known infrared companions. Aims. The primary goal of this project is to determine the physical and geometrical properties of the circumstellar and circumbinary material in the Haro 6-10 system. Methods. High-resolution optical (HST/WFPC2) and near-infrared (VLT/NACO) images in different bands were analysed to investigate the large-scale structures of the material around the binary.Mid-infrared interferometry (VLTI/MIDI) and spectroscopy (TIMMI2 at the 3.6m ESO telescope) were carried out to determine the structure and optical depth of the circumstellar material around the individual components. Results. The multi-wavelength observations suggest that both components of the binary system Haro 6-10 are embedded in a common envelope. The measured extinction indicates a dust ...
2011-01-01
Integration and Testing of the Micro-X Rocket Payload
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of ...
2011-05-01
Effects of local texture and grain structure on the sputtering performance of tantalum
Energy Technology Data Exchange (ETDEWEB)
Tantalum and tantalum-based thin films have gained precedence as the diffusion barrier for copper interconnects used in the latest generation of integrated circuits (ICs). The paper presents insight and observations on the covariance of texture and grain size of wrought tantalum sputtering targets and their influence on sputtering performance. Previous studies involving deposition trials of tantalum targets of varying metallurgical character had demonstrated that both grain size and textural homogeneity is critical for assuring reliable sputtering performance of tantalum. Subsequently, a model had been proposed to prescribe how localized texture bands and orientation clusters in tantalum are effectively resistant to sputter erosion. In this paper, results of atomic force microscopy (AFM) and orientation imaging microscopy (OIM{sup TM}) analyses on the eroded surface of a tantalum sputtering target are presented. Initial findings support the ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The structure of hydroxylated oxide films (passive films) formed on Cr(110) in 0.5 M H{sub 2}SO{sub 4} at +0.35, +0.55, and +0.75 V/SHE has been investigated by in situ scanning tunneling microscopy (STM). Cathodic reduction pretreatments at {minus}0.54, {minus}0.64, and {minus}0.74 V/SHE destroy the well-defined topography of the single-crystal electrode and they have been excluded from the passivation procedure. Two different passive film structures have been observed, depending on the potential and time of passivation. At low potential (+0.35 V/SHE), the passive film, consisting mostly of chromium hydroxide, has a noncrystalline and granular structure whose roughness suggests local variations of thickness of ca. {+-} 0.5 nm. A similar structure is observed at higher potential (+0.55 V/SHE), but only for a short polarization time. For longer polarization at 0.55 V/SHE, and at higher potentials (+0.75 V/SHE), a crystalline structure is formed; the higher the potential, the faster the ...
1999-09-16
Energy Technology Data Exchange (ETDEWEB)
Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub ...
1996-08-01
Development of a computerized portal verification scheme for pelvic treatment fields
International Nuclear Information System (INIS)
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV ...
1996-09-01
Real-time neutron radiography at the Iea-R1 m nuclear research reactor
International Nuclear Information System (INIS)
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was ...
2003-06-01
Imaging techniques for the injured ankle joint and tarsal bones
International Nuclear Information System (INIS)
In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to detect necrotic bone regions ...
Study of building materials impregnation processes by quasi-real-time neutron radiography
International Nuclear Information System (INIS)
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
1999-11-03
Review of progress in quantitative NDE. Abstracts
Energy Technology Data Exchange (ETDEWEB)
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
With respect to concept of resolution in seismic exploration using the reflection method, detailed considerations were given on processes of forming the resolution as a result of arranging observation points at vibration transmitting and receiving points. In the discussion, numerical experiments were carried out, in which the scattering stacking process is applied in a model having one scatterer existing in homogeneous media. The experiments investigated an imaging formation process of the scatterer when arrangement of the vibration transmitting and receiving points were changed from a coarse condition to a dense condition while the number of transmitting and receiving points is being increased. Resolution is created if waveforms having finite frequencies are used as input, and the imaging is performed by utilizing the limited number of vibration receiving and transmitting points. ...
1997-05-27
The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis
International Nuclear Information System (INIS)
Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)
2010-06-01
Shedding light on insight: Priming bright ideas
British Library Electronic Table of Contents (United Kingdom)
Previous research has characterized insight as the product of internal processes, and has thus investigated the cognitive and motivational processes that immediately precede it. In this research, however, we investigate whether insight can be catalyzed by a cultural artifact, an external object imbued with learned meaning. Specifically, we exposed participants to an illuminating lightbulb - an iconic image of insight - prior to or during insight problem-solving. Across four studies, exposing participants to an illuminating lightbulb primed concepts associated with achieving an insight, and enhanced insight problem-solving in three different domains (spatial, verbal, and mathematical), but did not enhance general (non-insight) problem-solving.
2010-01-01
UK PubMed Central (United Kingdom)
Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available
2011-03-01
Radioactive source management in Daya Bay NPP
International Nuclear Information System (INIS)
'Small radioactive source results in big accident' have occurred repeatedly in China and worldwide alike. Radioactive source management is one of the key activities for a nuclear power plant to maintain its good safety record and image to the public. From aspects of establishing the management system, centralized storage, periodic accounting, performing whole process control to the source usage and experience feedback etc., the author reports the practice and experience of radioactive source management in Daya Bay Nuclear Power Plant
1999-11-01
Lagrangian analysis of contaminant dispersal in bounded turbulent shear flows
Energy Technology Data Exchange (ETDEWEB)
Methods of solving Navier-Stokes equations for turbulent channel flow are given. These numerical solutions utilize either Neumann or Dirichlet boundary conditions. Computer codes were written and tested and are discussed. Digital image processing of flow visualization video sequences, taken simultaneously with vorticity probe measurements in a turbulent boundary layer, were carried out. 4 figs. (GHH)
1991-01-01
Data compression using artificial neural networks
Energy Technology Data Exchange (ETDEWEB)
This thesis investigates the application of artificial neural networks for the compression of image data. An algorithm is developed using the competitive learning paradigm which takes advantage of the parallel processing and classification capability of neural networks to produce an efficient implementation of vector quantization. Multi-Stage, tree searched, and classification vector quantization codebook design are adapted to the neural network design to reduce the computational cost and hardware requirements. The results show that the new algorithm provides a substantial reduction in computational costs and an improvement in performance.
1991-09-01
Clinical helical tomotherapy commissioning dosimetry
International Nuclear Information System (INIS)
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
2003-12-01
What can we learn about extragalactic radio jets from X-ray data?
We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.
2003-01-01
Thermoluminescence of irradiated RbCl and RbCl:Sn crystals
International Nuclear Information System (INIS)
The thermoluminescence (TL) and emission of coloured RbCl and RbCl:Sn crystals are studied in the temperature range 300 to 560 K. The glow peaks responsible for F centres and tin centres in different valence states are identified using optical bleaching studies. The glow peaks are analysed using total curve fitting method and the kinetic parameters are determined. In moderately #gamma#-irradiated tin-doped RbCl crystals, the TL emission bands observed at 4.0, 3.6, and 2.2 eV are attributed to Sn"0, Sn"+, and Sn"- centers, respectively. A comprehensive energy level diagram depicting the various TL processes in these undoped and tin-doped RbCl crystals is proposed. (author).
Spin qubits in antidot lattices
DEFF Research Database (Denmark)
We suggest and study designed defects in an otherwise periodic potential modulation of a two-dimensional electron gas as an alternative approach to electron spin based quantum information processing in the solid-state using conventional gate-defined quantum dots. We calculate the band structure and density of states for a periodic potential modulation, referred to as an antidot lattice, and find that localized states appear, when designed defects are introduced in the lattice. Such defect states may form the building blocks for quantum computing in a large antidot lattice, allowing for coherent electron transport between distant defect states in the lattice, and for a tunnel coupling of neighboring defect states with corresponding electrostatically controllable exchange coupling between different electron spins.
2008-01-01
Some characteristics of a novel direct thermal to optical energy converter medium
Energy Technology Data Exchange (ETDEWEB)
We have measured some of the optical characteristics of a novel energy conversion medium, over a range of compositions in the system Yb[sub 2]O[sub 3][minus]Al[sub 2]O[sub 3], which we have fabricated by a proprietary process. These specimens have good resistance to thermal shock, are durable, and are mechanically and chemically stable. The integrated emission of light generated by these unoptimized specimens when heated with a propane-air flame and detected with a silicon photodetector ranged up to 1.88 watts/cm[sup 2]. The emission spectrum from these specimens when heated with a propane-air flame and detected with a germanium photodetector shows a narrow band in the vicinity of 1 micron.
1995-01-05
International Nuclear Information System (INIS)
Passive films, formed on annealed and cold worked AISI 304 stainless steel in hot chloride media, were examined using polarization resistance and impedance measurements. The obtained results show the influence of cold work on film conductivity, which can be correlated to conditions of susceptibility to stress corrosion cracking. Capacitance measurements, using the Mott-Schottky approach, revealed that a change from n to p type semi-conductivity is associated to susceptible conditions with an increase in the doping density estimated for cold worked samples in the presence of chloride. It is assumed that p-type semi-conductivity of the passive film together with the position of the flat band potential has a strong influence on the dissolution processes at the corrosion potential. Based on this analysis the influence of plastic deformation, at the dislocation scale, is discussed. (authors)
2004-01-01
International Nuclear Information System (INIS)
This article describes the laser Thomson scattering principle and the developed system on HL-2A device. The high power Q-switch Nd:YAG laser, with a wavelength of 1064 nm, can sufficiently satisfy the measurement requirement. The polycromator consisting of avalanche photo-diodes(APD) and narrow band interference filters, can effectively improve the measurement of scattering light. The electron temperature is deduced by error-weighted lookup table method, which improves the data- processing speed or efficiency. Finally, the experiment results of the one-point electron temperature during different discharges of plasma are presented. (authors)
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of radiation observations.
2005-03-18
Energy Technology Data Exchange (ETDEWEB)
Coordination chemistry on transition metal chalcogenides offer better conditions for multielectron charge transfer processes on solid/electrolyte interfaces. In this contribution, materials whose band energies are derived from d-states of the transition metal will be shown. Problems related to the reactivity, stability and photoactivity toward the generation and conversion of fuels will also be discussed. (orig.) [Deutsch] Die an halbleitenden Uebergangsmetall-Elektroden beobachtete Koordinationschemie bietet guenstige Voraussetzungen fuer den Mehrelektronen-Transfer an der Festkoerper/Elektrolyt Grenzflaeche. Beispielhaft werden in diesem Beitrag Elektrodenmaterialien vorgestellt, deren Energiebaender sich von d-Zustaenden der Uebergangsmetalle herleiten. Diskutiert werden Probleme der Reaktivitaet, der Stabilitaet und der Photoaktivitaet im Hinblick auf die Erzeugung und Umsetzung von Brennstoffen. (orig.)
1995-02-01
Andreev reflection spectroscopy of MgB{sub 2} in the vortex state
Energy Technology Data Exchange (ETDEWEB)
Spectroscopy based on the Andreev reflection (AR) process at the interface between the normal metal tip and the superconductor has become one of the very successful methods for studies in novel exotic superconductors. The method is capable to address the size, symmetry as well as multiplicity of the superconducting order parameter. The method provided one of the first evidences of the two-gap superconductivity in MgB{sub 2} with a detailed temperature dependence of the both gaps. A theory treating the Andreev reflection spectroscopy in the mixed state is missing. We analyse the AR spectra of MgB{sub 2} in the mixed state via modelling the magnetic pair-breaking by the increasing spectral broadening parameter {gamma}. As a result a non-trivial pair breaking effect in the {pi}-band is found.
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
Calculating work-function modifications for flat-lying conjugated molecules on extended metal surfaces using density functional theory (DFT) is an extremely resource intensive task. This prevents fast screening of new molecules for their potential to optimize metal work functions for good electron or hole injection in organic electronic devices. We present a semi-classical model, which avoids that problem. This is achieved by identifying the dominant processes occurring at the interface between metal and adsorbate in the pinning-regime, which are then parameterizing their description using band-structure DFT calculations for a small training set With the resulting interdependent equations at hand, only simple gas-phase calculations are needed to predict the work-function changes induced by new molecules. The model is tested for ten molecules on three different metal surfaces, where it shows excellent agreement with photoelectron spectroscopy ...
2010-07-01
A comparison of the UHF Follow-On and MILSTAR satellite communication systems
The author compares the UHF Follow-On and MILSTAR satellite communication systems. The comparison uses an analytical hierarchy process. Although the two systems have been tasked with different missions, a comparison of cost, capability, and orbit is conducted. UFO provides many of the same capabilities as MILSTAR, but on a smaller scale. Since UFO is also a new space system acquisition, it is used to compare dollars spent to field a viable communication system. A review of frequency bands, losses, and problems is conducted to establish the relationship. Cost data is provided to establish the major difference in the systems. While MILSTAR does possess more total capability than UFO, it is 10 times more costly. Additionally, UFO is a satellite that will evolve with new technology while MILSTAR is built to full capability immediately. In the author's opinion, the incremental performance of MILSTAR does not justify its incremental cost.
1991-09-01
5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator
A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.
1984-03-01
Growth and electronic properties of two-dimensional systems on (110) oriented GaAs
Energy Technology Data Exchange (ETDEWEB)
As the only non-polar plane the (110) surface has a unique role in GaAs. Together with Silicon as a dopant it is an important substrate orientation for the growth of n-type or p-type heterostructures. As a consequence, this thesis will concentrate on growth and research on that surface. In the course of this work we were able to realize two-dimensional electron systems with the highest mobilities reported so far on this orientation. Therefore, we review the necessary growth conditions and the accompanying molecular process. The two-dimensional electron systems allowed the study of a new, intriguing transport anisotropy not explained by current theory. Moreover, we were the first growing a two-dimensional hole gas on (110) GaAs with Si as dopant. For this purpose we invented a new growth modulation technique necessary to retrieve high mobility systems. In addition, we discovered and studied the metal-insulator transition in thin bulk p-type layers on (110) GaAs. ...
2005-07-01
Optical Images Due to Lenses and Mirrors
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
The bands may be classified as primary if they merge into the eyewall encircling the eye of the storm, or secondary if they are disconnected from the ...
Investigation of lifetimes in the dipole band of {sup 139}Sm
Energy Technology Data Exchange (ETDEWEB)
Lifetimes have been measured for a dipole band in {sup 139}Sm using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (Shears mechanism with Principal Axis Cranking) models. The dipole band in {sup 139}Sm can be considered as a magnetic rotational band with a prolate or triaxial nuclear deformation. (orig.)
2008-09-15
Investigation of lifetimes in dipole bands of {sup 142}Gd
Energy Technology Data Exchange (ETDEWEB)
Lifetimes have been measured for dipole bands in {sup 142}Gd using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (shears mechanism with Principal Axis Cranking) models. The dipole bands DB1 to DB4 can be interpreted as magnetic rotational bands. (orig.)
2005-02-01
Proceedings of clinical SPECT [single photon emission computed tomography] symposium
International Nuclear Information System (INIS)
It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the ...
1986-09-22
Energy Technology Data Exchange (ETDEWEB)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...
2003-03-15
International Nuclear Information System (INIS)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...
2003-03-01
A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR
Energy Technology Data Exchange (ETDEWEB)
This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content ...
2005-04-01
Energy-band-structure studies of NbN(100) and VN(100)
Energy Technology Data Exchange (ETDEWEB)
Band-structure studies of NbN and VN are reported. The results of angle-resolved photoemission experiments performed on NbN/sub 0.93/ and VN/sub 0.89/ are presented. The bulk-band structures calculated for stoichiometric NbN and VN using the linearized augmented-plane-wave method are presented and utilized in the interpretation of the experimental spectra. It is shown that most of the features in the spectra can be accounted for by direct bulk-band transitions. A fairly good agreement between experimental and calculated band locations and dispersions is obtained.
1985-07-15
The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers
International Nuclear Information System (INIS)
Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT ...
2000-12-01
RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION
International Nuclear Information System (INIS)
We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is ...
2009-04-10
Focused ion beam damage to MOS integrated circuits
Energy Technology Data Exchange (ETDEWEB)
Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. ...
2000-05-10
Two-photon calcium imaging from head-fixed Drosophila during optomotor walking behavior
British Library Electronic Table of Contents (United Kingdom)
Drosophila melanogaster is a model organism rich in genetic tools to manipulate and identify neural circuits involved in specific behaviors. Here we present a technique for two-photon calcium imaging in the central brain of head-fixed Drosophila walking on an air-supported ball. The ball's motion is tracked at high resolution and can be treated as a proxy for the fly's own movements. We used the genetically encoded calcium sensor, GCaMP3.0, to record from important elements of the motion-processing pathway, the horizontal-system lobula plate tangential cells (LPTCs) in the fly optic lobe. We presented motion stimuli to the tethered fly and found that calcium transients in horizontal-system neurons correlated with robust optomotor behavior during walking. Our technique allows both behavior ...
2010-01-01
The kinematics of coronal mass ejections using multiscale methods
The diffuse morphology and transient nature of coronal mass ejections (CMEs) make them difficult to identify and track using traditional image processing techniques. We apply multiscale methods to enhance the visibility of the faint CME front. This enables an ellipse characterisation to objectively study the changing morphology and kinematics of a sample of events imaged by the Large Angle Spectrometric Coronagraph (LASCO) onboard the Solar and Heliospheric Observatory (SOHO) and the Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) onboard the Solar Terrestrial Relations Observatory (STEREO). The accuracy of these methods allows us to test the CMEs for non-constant acceleration and expansion. We exploit the multiscale nature of CMEs to extract structure with a multiscale decomposition, akin to a Canny edge detector. Spatio-temporal filtering highlights the CME front as it propagates in time. We apply an ...
2009-01-01
Symbolic image understanding. Final report Sep 87-Aug 90
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the work done at the University of Massachusetts in the area of Image Understanding of static scene domains. The goal of this research project was to demonstrate a practical knowledge-based approach to computer vision that utilized multiple levels of parallel processing. Some problems dealt with included extracting lines, grouping together regions and lines from the same surface, computing pose from geometry, and matching corresponding features in different views. Special attention was also given to the extraction of curved lines and curved surfaces. The static scene domains consisted of both ROAD and HOUSE scenes, each containing approximately fourteen (14) different objects per scene.
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
2001-01-01
International Nuclear Information System (INIS)
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
Real-time imaging for neutron radiography at KURRI
International Nuclear Information System (INIS)
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
1987-07-01
Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
This article focuses on visual representations of subjective experiences of the process of recovery from addiction and the meanings that participants attribute to their visual work. The data are drawn from a study of six female participants. In this article, we discuss the results with reference to one participant, to allow for detailed consideration of the visual and the verbal material. This participant was selected because of the richness of her material, which provided an opportunity to carry out a detailed case study. Potential participants were informed in advance that they would be asked to draw during the interview. They were also asked to bring to the interview some artwork made during their engagement in creative activities at an earlier stage in their recovery. The data were ana...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)
2007-11-15
Die Backside FIB Preparation for Identification and Characterization of Metal Voids
Energy Technology Data Exchange (ETDEWEB)
Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view ...
1999-07-28
Temperature dependence of the performance of ultraviolet detectors
Energy Technology Data Exchange (ETDEWEB)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric field in the ...
2003-08-21
Temperature dependence of the performance of ultraviolet detectors
International Nuclear Information System (INIS)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric field in the ...
2003-08-21
Thin-film solar cells on flexible, lightweight, space-qualified substrates provide an attractive approach to fabricating solar arrays with high mass-specific power. A polycrystalline chalcopyrite absorber layer is among the new generation of photovoltaic device technologies for thin film solar cells. At NASA Glenn Research Center we have focused on the development of new single-source precursors (SSPs) for deposition of semiconducting chalcopyrite materials onto lightweight, flexible substrates. We describe the syntheses and thermal modulation of SSPs via molecular engineering. Copper indium disulfide and related thin-film materials were deposited via aerosol-assisted chemical vapor deposition using SSPs. Processing and post-processing parameters were varied in order to modify morphology, stoichiometry, crystallography, electrical properties, and optical properties to optimize device quality. Growth at atmospheric pressure in a horizontal ...
2008-01-01
Defect engineering via ion implantation to control B diffusion in Si
International Nuclear Information System (INIS)
The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the technological ...
2009-03-15
Language and Music in the Musician Brain
British Library Electronic Table of Contents (United Kingdom)
Abstract Results of numerous experiments conducted over the past 15-years by using behavioural as well as brain imaging methods have shown that musical expertise influences brain anatomy, brain functions and behaviour. The musician- brain is thus considered as a very good model of brain plasticity. Moreover, many results have demonstrated that musical expertise not only impacts on music processing but also on several aspects of speech processing including lexical pitch, sentence intonation and the metric structure of words. Conversely, recent results indicated that linguistic expertise with tone or quantity languages such as Mandarin Chinese, Thai, Finnish and Japanese, influences the processing of harmonic tones and musical intervals. We discuss possible interpretations of these findings ...
2011-01-01
Java Image I/O for VICAR, PDS, and ISIS
This library, written in Java, supports input and output of images and metadata (labels) in the
2011-01-01
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes ...
2011-05-05
The hurried development of multimedia and internet allows for wide distribution of digital media data. It becomes much easier to edit, modify and duplicate digital information. In additional, digital document is also easy to copy and distribute, therefore it may face many threats. It became necessary to find an appropriate protection due to the significance, accuracy and sensitivity of the information. Furthermore, there is no formal method to be followed to discover a hidden data. In this paper, a new information hiding framework is presented.The proposed framework aim is implementation of framework computation between advance encryption standard (AES) and distortion technique (DT) which embeds information in image page within executable file (EXE file) to find a secure solution to cover file without change the size of cover file. The framework includes two main functions; first is the hiding of the information in the image page of EXE file, ...
2009-01-01
In-situ focused ion beam (FIB) microscopy at high temperature
International Nuclear Information System (INIS)
Materials Scientists need information on the kinetics of the microstructural evolution processes that determine the finished microstructure, and hence the properties, of any material. E.g. recrystallisation, grain growth and phase changes. Such kinetic information requires reliable discrimination of differently oriented crystallites and/or different crystal phases coupled with useful spatial resolution and temporal resolution (i.e. high frame rates). These imaging results must be realised from a hot and changing specimen, in an instrument that is compatible with that hot specimen and with a practical specimen heater. Focused Ion Beams (FIB) offer strong contrast between crystallites and phases, and hence offer the ability to discriminate between these features even while imaging at fast frame rates, however their compatibility with hot specimens was unproven. Here we report results from a novel combination of FIB with an ...
2008-08-01
International Nuclear Information System (INIS)
Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be ...
1999-10-01
Energy Technology Data Exchange (ETDEWEB)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 ...
1989-02-01
International Nuclear Information System (INIS)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 ...
1989-01-01
Diagnosis for the cancer extension of cholangiocarcinoma. The current status
International Nuclear Information System (INIS)
Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void ...
1995-01-01
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, ...
1981-01-01
An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial ...
2010-07-19
The optical and structural properties of polycrystalline Cu(In,Ga)(Se,S)2 absorber thin films
British Library Electronic Table of Contents (United Kingdom)
The pentenary compound semiconductor Cu(In,Ga)(Se,S)2 is one of the most attractive materials for high-efficiency solar cells due to its tunable band gap to match well the solar spectrum. In this study, semiconducting Cu(In,Ga)(Se,S)2 thin films were prepared by a classical two-step growth process, which involves the selenization and/or sulfurization of In/Cu?Ga precursor. During the precursor formation step metallic In/Cu?Ga alloys were deposited onto the Mo-coated soda-lime glass substrates by DC magnetron sputter process. The respective precursors were subsequently reacted with H2Se and/or H2S gasses, at elevated temperatures. By optimizing the selenization parameters, such as the gas concentrations, reaction time, reaction temperature, and the flow of H2Se and H2S, high quality, single...
2011-01-01
International Nuclear Information System (INIS)
In this study, free electron laser (FEL) with selective wavelength was used to induce structure changes of biomolecules, which were characterized by FTIR spectroscopy. For understanding of the interactions between FEL and biomolecules as well as biological tissues, the biomolecules investigated are ATP, ADP, AMP, t-RNA, D-ribose and the complex of SmCl_3-D-ribose. Their FTIR spectra before and after irradiation of FEL show molecular structure variations of the samples after irradiation of FEL, especially the rearrangement of their hydrogen bond networks. Along with the various irradiation wavelengths, irradiation time and molecular structures, the changes after irradiation are different for these molecules. In the FTIR spectra after irradiation, the phenomenon that the bands split into several peaks indicates the existence of several structures, conformations and configurations, which may be prompted by multiple photons process induced by FEL. ...
2007-05-01
The Application of Spatial Signature Analysis to Electrical Test Data: Validation Study
Energy Technology Data Exchange (ETDEWEB)
This paper presents the results of the Spatial Signature Analysis (SSA) Electrical-test (e-test) validation study that was conducted between February and June, 1998. SSA is an automated procedure developed by researchers at the Oak Ridge National Laboratory to address the issue of intelligent data reduction while providing feedback on current manufacturing processes. SSA was initially developed to automate the analysis of optical defect data. Optical defects can form groups, or clusters, which may have a distinct shape. These patterns can reveal information about the manufacturing process. Optical defect SSA uses image processing algorithms and a classifier system to interpret and identify these patterns, or signatures. SSA has been extended to analyze and interpret electrical test data. The algorithms used for optical defect SSA have been adapted and applied to e-test binmaps. An ...
1999-03-15
A non-local approach for image super-resolution using intermodality priors ?
UK PubMed Central (United Kingdom)
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
2010-08-01
Spread spectrum acquisition and tracking performance for Shuttle communication links
The spread spectrum acquisition and tracking performance for the Shuttle S-band and Ku-band communication links are analyzed and compared to test results. The S-band link requirements are more severe than those of the Ku-band links, hence, different despreader designs were developed for the two systems. The S-band despreader acquires pseudonoise code lock by examining all possible code phases in half chip steps while the Ku-band despreader acquires pseudonoise code lock by continuously sweeping a tau-jitter loop. Both despreaders employ a tau-jitter loop for code tracking. The code tracking performance is computed for the tau-jitter loop and compared to that of the more complex delay lock loop.
1978-01-01
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
International Nuclear Information System (INIS)
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...
2009-03-01
Reflection tomography using finite element method ray tracing
Energy Technology Data Exchange (ETDEWEB)
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate ...
1996-12-01
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should ...
1992-07-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
Energy Technology Data Exchange (ETDEWEB)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and ...
1987-04-01
We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
1989-06-01
International Nuclear Information System (INIS)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
1989-01-01
Digital subtraction angiography with scanning lazer stimulated luminescence
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, ...
1985-01-01
DNA cleavage on photoexposure at the d-d band in ternary copper(II) complexes using red-light laser.
Ternary copper(II) complexes [Cu(L1)B](ClO4) (1, 2) and [Cu(L2)B](ClO4) (3, 4), where HL1 and HL2 are tridentate NSO- and ONO-donor Schiff bases and B is a heterocyclic base, viz. dipyrido[3,2-d:2',3'-f]quinoxaline (dpq, 1 and 3) or dipyrido[3,2-a:2',3'-c]phenazine (dppz, 2 and 4), were prepared and their DNA binding and photoinduced DNA cleavage activity studied. Complex 1, structurally characterized by single-crystal X-ray crystallography, shows an axially elongated square-pyramidal (4 + 1) coordination geometry in which the monoanionic L1 binds at the equatorial plane. The NN-donor dpq ligand exhibits an axial-equatorial binding mode. The complexes display good binding propensity to calf thymus DNA, giving a relative order 2 (NSO-dppz) > 4 (ONO-dppz) > 1 (NSO-dpq) > 3 (ONO-dpq). They cleave supercoiled pUC19 DNA to its nicked circular form when treated with 3-mercaptopropionic acid (MPA) by formation of hydroxyl radicals as the cleavage active species under dark reaction ...
2006-12-25
A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography
International Nuclear Information System (INIS)
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both ...
1999-11-01
Probing dark energy with the shear-ratio geometric test
We adapt the Jain-Taylor (2003) shear-ratio geometric lensing method to measure the dark energy equation of state, w = pv/?v and its time derivative from dark matter haloes in cosmologies with arbitrary spatial curvature. The full shear-ratio covariance matrix is calculated for lensed sources, including the intervening large-scale structure and photometric redshift errors as additional sources of noise, and a maximum likelihood method for applying the test is presented. Decomposing the lensing matter distribution into dark matter haloes we calculate the parameter covariance matrix for an arbitrary experiment. Combining with the expected results from the cosmic microwave background (CMB) we design an optimal survey for probing dark energy. This shows that a targeted survey imaging 60 of the largest clusters in a hemisphere with five-band optical photometric redshifts to a median galaxy depth of zm = 0.9 could measure w0 ? w(z = 0) to a marginal ...
2007-02-01
Effect of the fabrication process on fatigue performance of U3Si2 fuel plate with sandwich structure
U3Si2 Al fuel plate is one of the dispersion fuel structure materials recently developed and widely used in research reactors. The mechanical properties of this structural material, especially the fatigue performance, are strongly dependent on its fabrication process. To investigate the effects of these processing technologies, the fatigue tests for the different specimens were carried out. The S N curves indicate that the fabrication processing technologies of U3Si2 fuel plate, such as the addition of U3Si2 particles into aluminum powder to form the fuel meat, holding and rolling the processes of meat and cladding of 6061-Al alloy, plays an important role in improving the mechanical properties and fatigue performance of this fuel plate. In addition, some factors that influence the crack initiation and propagation are summarized based on the fatigue images that are in situ ...
2005-06-01
Video Analysis Transputer Array (VATA)
Energy Technology Data Exchange (ETDEWEB)
This paper presents (a) an overview of the Inmos transputer and its use in parallel arrays for image processing, (b) a functional block-level description of IBM-AT-compatible boards for signal/image processing research using transputers with reconfigurable interconnection topologies, and (c) an overview of the OCCAM and C programming tools for placing parallel algorithms onto such a processor. The hardware consists of two custom printed-circuit boards (and two commercially available boards) within an IBM-AT host. The first provides a flexible input/output interface between a general-purpose high-speed input-data bus and the transputer array. The second contains 32 transputers and 4 programmable crossbar-switch interconnection chips. Several copies of the second board can be cascaded (or even partially-unpopulated) to provide for an arbitrary number of transputer chips. Each one of these boards will ...
1988-08-19
VSP reverse-time migration using two-way nonreflection wave equation
Energy Technology Data Exchange (ETDEWEB)
VSP data are usually recorded in common-shot gather and contain less informations. It is difficult, therefore, to obtain good migration result by using conventional migration methods. Both inner interface reflections and interformational multiples can be removed by reverse-time migration with the use of two-way nonreflection wave equation: besides, boundary reflection in VSP can be eliminated using Clayton's absorption boundary condition. It is proved that reverse-time migration is able to improve migration quality. The imaging condition is still obtained by generalizing Claerbout's imaging principle and solving eikonal equation. This is a very practical wave equation migration method. This method is applicable to prestack VSP data, conventional multiple-offset shot gather and the simultaneous migration of VSP data and surface seismic data. Besides, it is adaptable to various velocity variations. Before applying the method to ...
1989-01-01
Surface oxidation processes in compound semiconductors studied by profile imaging
International Nuclear Information System (INIS)
The profile imaging technique is used to study the oxidation of ZnTe and InP surfaces induced by in situ reaction due to the electron beam of the microscope and by ex situ heating in air. For both materials, in situ reaction with the electron beam resulted in desorption of the anion species and the formation of the metal oxide. The observation of In metal particles, and the fact that the rate of formation of In_2O_3 was substantially reduced by an improvement of the vacuum near the specimen region, suggested that the presence of oxygen is not involved in the desorption process. The ex situ heating of ZnTe up to 260 degrees C in air resulted in crystals of ZnO and Te metal, generally in a layered surface region with the sequence of ZnTe/Te/ZnO. The large Te crystals usually had an epitaxial relationship with the bulk ZnTe but the small ZnO crystals had random orientations. The ex situ heating of InP to 380 degrees C in air only gave rise to ...
Energy Technology Data Exchange (ETDEWEB)
Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. ...
1986-07-01
Energy Technology Data Exchange (ETDEWEB)
The authors will be conducting an integrated seismic experiment to image the structure of the crust and upper mantle of northern California immediately before and after passage of the Mendocino Triple Junction. The purpose of this representation is to describe the project to other scientists interested in geological and geophysical processes in this region and to solicit input relevant to detailed siting of the funded seismic profiles. The experiment encompasses two field seasons: onshore seismic refraction/wide angle reflection data acquisition along three long profiles scheduled for late summer, 1993; and MCS deep crustal seismic reflection data acquisition accompanied by simultaneous large aperture recording using both ocean bottom and onshore seismographs, tentatively scheduled for summer, 1994. This study represents a component of a long-term, multi-disciplinary effort on the part of many investigators to exploit this well defined system ...
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
The video documents the results of a Small Business Innovative Research (SBIR-Phase II) project conducted for DARPA focusing on the use of all-source overhead remote sensor imagery for monitoring underground nuclear tests and related activities. The documentation includes: (1) the main unclassified body of the report; (2) a separate ground truth Annex; and (3) a separate classified Annex. Autometric's approach was to investigate the exploitation potential of the various sensors, especially the fusion of products from them in combination with each other and other available collateral data. This approach featured empirical analyses of multisensor/multispectral imagery and collateral data collected before, during, and after an actual underground nuclear test (named 'BEXAR'). Advanced softcopy digital image processing and hardcopy image interpretation techniques were investigated for the research. ...
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)
2000-07-01
Three-frame Algorithm of Car Path Reconstruction from Airborne Traffic Data
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
2007-01-01
Similarity between the primary and secondary air-assisted liquid jet breakup mechanism
we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.
2007-01-01
Quantitative density measurements from a real-time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-01-01
Quantitative density measurements from a real-time neutron radiography system
International Nuclear Information System (INIS)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-11-16
Environmental scanning electron microscopy
Energy Technology Data Exchange (ETDEWEB)
The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.
1994-12-31
Application of neutron radiography to visualization of multiphase flows
Energy Technology Data Exchange (ETDEWEB)
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
1990-04-01
Application of neutron radiography to visualization of multiphase flows
International Nuclear Information System (INIS)
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
1990-01-01
Application of neutron radiography to a diagnosis of refrigerator
International Nuclear Information System (INIS)
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
1996-07-01
UK PubMed Central (United Kingdom)
To study the topographical organization of mu and beta band event-related desynchronization (ERD) associated with voluntary hand and foot movements, we used magnetoencephalographic (MEG) recordings...Full Text Available
Theoretical study of lithium isotope separation by displacement chromatography
Energy Technology Data Exchange (ETDEWEB)
Lithium isotope separation by displacement chromatography is studied using fundamental principles; the equations are derived assuming theoretical stages in lithium adsorption bands. The concentration profiles in the band are calculated numerically under unsteady state.
1982-01-01
... Fluctuating Incubation Temperatures in the Multi-banded Krait, Bungarus multicintus (Elapidae)Xiang Ji1,2,*, Jian-Fang Gao1, ... rather than applying constant-temperature regimes. We incubated Bungarus mu...
Civil and Military Satellite Communications: A Systems ...
... to-noise density than the uplink budget has (74.2 ... in heav:, point-to-point link applications with ... 11.7 Expanded bands allocated (Ku band) (500 MHz ...
1991-02-01
Characterizing the spectral-temporal response of ... - MODIS Website
... days after it burned, using a portable spectroradiometer (704 bands in the range 0.35 to 2.5 mu m) and an infrared thermometer (one band, 6 to 14 mu m). ...
Interface engineering in chalcopyrite thin film solar devices
Energy Technology Data Exchange (ETDEWEB)
Successful interface engineering requires compositional and electronic material characterization as a prerequisite for understanding and intentionally generating interfaces in photovoltaic devices. The paper gives an overview with several examples, all referring to Cu(In,Ga)(S,Se){sub 2} ('CIGSSe')-based solar cells, with an emphasis on characterization using highly specialized methods, such as elastic recoil detection analysis, X-ray emission spectroscopy and photoelectron spectroscopy using synchrotron and ultraviolet light for excitation, inverse photoemission spectroscopy and Kelvin probe force microscopy. First, the determination of the depth profile of the band gap energy E{sub g} in the absorber layer is demonstrated. The modification of E{sub g} towards both interfaces is discussed in terms of beneficial electronic effects. Next, the interface between absorber and buffer layers with alternative and promising non-toxic materials is ...
2006-06-15
Development of Intelligent Setting System for Fracture Based on X-Ray Image
Energy Technology Data Exchange (ETDEWEB)
In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power ...
2006-10-15
Rotational band-structures in transitional odd-A nuclei
International Nuclear Information System (INIS)
... deformed nuclei eigenvalues even-odd nuclei gold 195 hamiltonians iridium
Measurement of AlP/GaP (001) heterojunction band offsets by x-ray photoemission spectroscopy
Energy Technology Data Exchange (ETDEWEB)
X-ray photoemission spectroscopy has been used to measure the valence band offset {Delta}E{sub v} for the AlP/GaP (001) heterojunction interface. The heterojunction samples were prepared by molecular-beam epitaxy. A value of {triangle}E{sub v}=0.43 eV is obtained (staggered band alignment, with AlP valence band below that of GaP). 24 refs., 8 figs., 1 tab.
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
Lifetimes have been measured in the {pi}h{sub 9/2} (yrast) and {pi}i{sub 13/2} (excited) bands in the nuclei {sup 181}Ir and {sup 187}Au using the Recoil Distance Method (RDM). The results clearly indicate that the {pi}i{sub 13/2} band exhibits an increased deformation over the {pi}h{sub 9/2} band, in keeping with the premise that the delayed crossing in this band is due to enhanced quadrupole deformation. (author). 3 refs, 1 fig, 2 tab.
1995-02-01
Lifetime in "1"8"1Ir and "1"8"7Au: enhanced deformation of the #pi#i _1_3_/_2 intruder orbital
International Nuclear Information System (INIS)
Lifetimes have been measured in the #pi#h_9_/_2 (yrast) and #pi#i_1_3_/_2 (excited) bands in the nuclei "1"8"1Ir and "1"8"7Au using the Recoil Distance Method (RDM). The results clearly indicate that the #pi#i_1_3_/_2 band exhibits an increased deformation over the #pi#h_9_/_2 band, in keeping with the premise that the delayed crossing in this band is due to enhanced quadrupole deformation. (author). 3 refs, 1 fig, 2 tab.
1994-09-05
Recursive neural networks for processing graphs with labelled edges: theory and applications.
In this paper, we introduce a new recursive neural network model able to process directed acyclic graphs with labelled edges. The model uses a state transition function which considers the edge labels and is independent both from the number and the order of the children of each node. The computational capabilities of the new recursive architecture are assessed. Moreover, in order to test the proposed architecture on a practical challenging application, the problem of object detection in images is also addressed. In fact, the localization of target objects is a preliminary step in any recognition system. The proposed technique is general and can be applied in different detection systems, since it does not exploit any a priori knowledge on the particular problem. Some experiments on face detection, carried out on scenes acquired by an indoor camera, are reported, showing very promising results. PMID:16181770
2005-09-21
British Library Electronic Table of Contents (United Kingdom)
In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.
2011-01-01
International Nuclear Information System (INIS)
The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2005-03-01
Energy Technology Data Exchange (ETDEWEB)
Theoretical and experimental data which have defined and/or extended the effectiveness of remote sensing operations are explored, with consideration given to both scientific and commercial activities. The remote sensing of soil moisture, the sea surface, and oil slicks is discussed, as are programs using satellites for studying geodynamics and geodesy, currents and waves, and coastal zones. NASA, Canadian, and Japanese radar and microwave passive and active systems are described, together with algorithms and techniques for image processing and classification. The SAR-580 project is outlined, and attention is devoted to satellite applications in investigations of the structure of the atmosphere, agriculture and land use, and geology. Design and performance features of various optical scanner, radar, and multispectral data processing systems and procedures are detailed.
1982-01-01
Search for magnetic rotation in {sup 202}Pb and {sup 203}Pb
Energy Technology Data Exchange (ETDEWEB)
High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)
2000-11-01
View larger image for ISS022-E-26137 - Earth Sciences and Image ...
The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...
Advances in Imaging of Vertebral and Spinal Cord Injury
UK PubMed Central (United Kingdom)
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
2010-04-01
3 - NASA Technical Report Server (NTRS)
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
1990-01-01
Unsymmetrically substituted n-type perylene bisimides with liquid crystalline properties
Energy Technology Data Exchange (ETDEWEB)
Perylene bisimides (PBIs) represent an important class of organic n-type semiconductors exhibiting a relatively high electron affinity among large-band-gap materials. Herein synthesis and characterization of several unsymmetrical N-substituted PBI dyes is presented and the thermotropic behavior, which is strongly affected by the respective N-substituents was investigated. Two different series of highly soluble and fluorescent derivatives have been synthesized: (1) PBIs bearing swallow-tailed alkyl chains, different in size or (2) one swallow-tailed alkyl chain and one branched oligoethylenglycolether. Synthesis of these PBIs is generally feasible by two distinct divergent synthesis approaches. Thermotropic behavior was studied by DSC, POM and XRD measurements. Inherent {pi}-{pi} interactions between cofacially orientated perylene molecules and the elliptic shape of the molecule favor the ordering in columns and self-organized architectures. Among them hexagonal ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Passive films, formed on annealed and cold worked AISI 304 stainless steel in hot chloride media, were examined using polarization resistance and impedance measurements. The obtained results show the influence of cold work on film conductivity, which can be correlated to conditions of susceptibility to stress corrosion cracking. Capacitance measurements, using the Mott-Schottky approach, revealed that a change from n to p type semi-conductivity is associated to susceptible conditions with an increase in the doping density estimated for cold worked samples in the presence of chloride. It is assumed that p-type semi-conductivity of the passive film together with the position of the flat band potential has a strong influence on the dissolution processes at the corrosion potential. Based on this analysis the influence of plastic deformation, at the dislocation scale, is discussed. (authors)
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
[alpha]-Melanocyte stimulating hormone ([alpha]-MSH), a hormone originally named for its ability to regulate pigmentation of melanocytes, is a 13-amino-acid post-translational product of the pro-opiomelanocortin (POMC) gene. [alpha]-MSH and the other products of POMC processing, which share the core heptapeptide amino acid sequence Met-Glu (Gly)-His-Phe-Arg-Trp-Gly (Asp), the adrenocorticotropic hormone (ACTH), [beta]-MSH, and [gamma]-MSH, are collectively referred to as melanocortins. While best known for their effects on the melanocyte (pigmentation) and adrenal cortical cells (steroidogenesis), melanocortins have been postulated to function in diverse activities, including enhancement of learning and memory, control of the cardiovascular system, analgesia, thermoregulation, immunomodulation, parturition, and neurotrophism. To identify the chromosomal band encoding the human melanocortin-1 receptor gene, 1 [mu]g of an EMBL clone coding region ...
1994-01-15
Simplified electrostatic model for band-gap underestimates in the local-density approximation
An estimate of the undercounted electrostatic energy terms in local-density-functional total-energy calculations for nonmetallic systems with separated electron-hole pairs is used to derive a simplified correction to density-functional - theory band gaps. The correction is evaluated for Ne, Ar, Kr, LiF, NaCl, CsCl, MgO, CaS, BaS, C, AlP, and Si. The band-gap errors are reduced from 40-50% to 10-15% for most of the systems studied. Conduction-band corrections are shown to be nearly as large as valence-band corrections in free-electron-like semiconductors. 28 references, 1 figure.
1985-04-15
Use of SPOT satellite imagery to obtain GIS input for oil spill models
Energy Technology Data Exchange (ETDEWEB)
Satellite imagery is a cost-effective tool for creating and updating basemaps of coastal zones, especially where existing maps and aerial photographs are unavailable, are out-of-date, or provide limited information. Reliable maps of coastal zones are particularly important for oil spill modelling programs. Color IR (multispectral) images with 20m x 20m ground resolution and black & white (panchromatic) images with 10m x 10m ground resolution of many coastlines around the globe have been acquired from 1986 to present by SPOT Image Corporation. We have digitally merged same-day SPOT panchromatic and multispectral imagery to provide maximum spatial resolution and permit excellent color differentiation of coastal zone features. This combination adequately discriminates individual features, including pipelines, offshore platforms, storage tanks, jetties, and shoreline type. The SPOT images were ...
1995-04-01
Real-time neutron radiography; Radiografia com neutrons em tempo-real
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. ...
2000-07-01
International Nuclear Information System (INIS)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...
2000-01-01
International Nuclear Information System (INIS)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR ...
2002-12-01
Peripheral cholangiocarcinoma : three-phase helical CT appearance
International Nuclear Information System (INIS)
To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be hypoattenuating, as compared to the surrounding parenchyma. On HAP, ...
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das Lig. talofibulare ...
1996-03-01
AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography
International Nuclear Information System (INIS)
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right ...
2000-06-01
Simple fractal method of assessment of histological images for application in medical diagnostics
UK PubMed Central (United Kingdom)
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy
UK PubMed Central (United Kingdom)
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
UK PubMed Central (United Kingdom)
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
1993-01-01
Advances in Modeling of Scanning Charged-Particle-Microscopy Images
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
2010-01-01
Magnetic resonance imaging in childhood epilepsy
International Nuclear Information System (INIS)
The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.
Esters useful as brain imaging agents
Energy Technology Data Exchange (ETDEWEB)
Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.
1981-08-18
Esters useful as brain imaging agents
International Nuclear Information System (INIS)
Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.
Amides useful as brain imaging agents
Energy Technology Data Exchange (ETDEWEB)
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
1981-07-21
Amides useful as brain imaging agents
International Nuclear Information System (INIS)
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
Energy Technology Data Exchange (ETDEWEB)
In this paper, the turbulence structures of premixed impinging jets are investigated by three different experimental techniques: time-resolved particle image velocimetry (TPIV) visualisation, hot wire anemometry (HWA) and acoustic signal processing. The focus is on the TPIV, with the other two techniques providing supplementary information. The 2-D velocities of the impinging jets were obtained by TPIV. The contour maps of velocity derivatives were computed to facilitate the visualisation of the turbulence structure of the reactant part of turbulent impinging flames. Particular attention was concentrated on the turbulence structures out of the burner nozzle and their interactions with the combustion process. It was found that the contour plots are effective in visualising time-dependent structures. It is demonstrated that the derivatives of the velocity field are able to reveal many otherwise hidden turbulence patterns. ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
2008-03-21
The magnetic resonance and its agro-industry applications; a review
International Nuclear Information System (INIS)
The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...
Surface brightness and effective radius for elliptical galaxies
International Nuclear Information System (INIS)
Seeing convolved two-dimensional de Vaucouleurs profiles have been fitted to digital images of the brightest elliptical galaxies in two nearby groups of galaxies and three clusters of galaxies with redshifts in the range 0.06 to 0.15. The digital images were created by scanning electronographic plates obtained by the use of several versions of the RGO electronographic camera. The linear relation between effective surface brightness #mu#/sub e/ and the logarithm of the effective radius r/sub e/, first discovered by Kormendy to be valid for nearby elliptical galaxies, is found to be equally valid for the largest and brightest galaxies in rich clusters of galaxies. The apparent universal nature of that relation indicates that the same type of processes might have been involved during the formation of all ellipticals from cD galaxies in clusters to fainter ellipticals in small groups. It is suggested that the (I/sub e/,r/sub ...
Skeletal remodeling dynamics: New approaches with imaging instrumentation
Energy Technology Data Exchange (ETDEWEB)
This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) ...
1991-12-01
Research and development of neutron radiography in IAERU
Energy Technology Data Exchange (ETDEWEB)
In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for NR, the imaging apparatuses of cooled type CCD, SIT and superhigh sensitivity, the ...
1995-03-01
Real-time neutron radiography system performance - Measurements and methods
Energy Technology Data Exchange (ETDEWEB)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the ...
1988-09-01
Real-time neutron radiography system performance - Measurements and methods
International Nuclear Information System (INIS)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the ...
1988-01-01
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...
1989-03-01
Energy Technology Data Exchange (ETDEWEB)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
1984-08-01
International Nuclear Information System (INIS)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
Near-surface 3D reflections seismic survey; Sanjigen senso hanshaho jishin tansa
Energy Technology Data Exchange (ETDEWEB)
Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of local disaster prevention in big cities. Using as the model the Tachikawa fault that ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
The microstructure of the secondary deformation zone (SDZ) near the cutting surface in metal chips of Ti-6Al-4V formed during machining was investigated using focused ion beam (FIB) specimen preparation and transmission electron microscopy (TEM) imaging. Use of the FIB allowed precise extraction of the specimen across this region to reveal its inhomogeneous microstructure resulting from the non-uniform distribution of strain, strain rate, and temperature generated during the cutting process. Initial imaging from conventional TEM foil preparation revealed microstructures ranging from heavily textured to regions of fine grains. Using FIB preparation, the transverse microstructure could be interpreted as fine grains near the cutting surface which transitioned to coarse grains toward the free surface. At the cutting surface a 10 nm thick recrystallized layer was observed capping a 20 nm thick amorphous layer.
2011-01-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant ...
2002-07-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
International Nuclear Information System (INIS)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant ...
2002-08-11
Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT
Energy Technology Data Exchange (ETDEWEB)
Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard kernel for the abdomen and is inferior with the high-definition kernel for the ears/bones. By performing sharpening filter ...
2007-02-07
Focused ion beam machined nanostructures depth profiled by macrochannelling ion beam analysis
International Nuclear Information System (INIS)
High aspect ratio sub-#mu#m periodic structures fabricated by focused ion beam (FIB) lithography have been characterised by Rutherford backscattering spectrometry (RBS) using the macrochannelling technique. The technique overcomes the limitations of complementary techniques such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), which can provide images with sub-#mu#m resolution of just the surface features and not of the deep sub-surface structures, without destructive cross sectioning of the sample. Here RBS macrochannelling with a 2 MeV He"+ ion beam is used to analyse a diffraction grating fabricated by FIB milling an array of 100 nm wide trenches in a 300 nm thick Ag film on a Si substrate. Using the surface structure imaged by SEM and AFM as a starting point, a numerical model for the RBS spectrum from the grating is fitted to the experimental spectrum as a function of the sub-surface structure. This ...
2006-08-01
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any ...
2007-04-22
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly ...
2008-02-01
Elastic modeling and steep dips: unraveling the reflected wavefield
Energy Technology Data Exchange (ETDEWEB)
As part of a larger elastic numerical modeling project, we have been investigating how energy reflected from steeply dipping interfaces is recorded using typical multicomponent acquisition geometries. Specifically, we have been interpreting how rcflection events from the flanks of salt dome structures are distributed on 3C and 4C phones for vertical seismic profiles (VSPs) and ocean bottom seismic (OBS) or land surface surveys. The ultimate goal of this investigation is to improve the structural imaging of steeply dipping interfaces and eventually to evaluate the usc of the recorded elastic wavefield for fluid description near these interfaces. In the current work, we focus on a common assumption used when processing converted wave reflection seismic data that most PP energy is recorded on the vertical geophone and/or the hydrophone and that most PS energy is recorded on the horizontal geophones. This is a useful assumption when it is valid, ...
2003-01-01
A novel nanoglue and whole wafer self-alignment based upon self-assembled monolayers
New methodologies for fabrication of multilevel packaging, particularly for RF signal analysis, are investigated. A new method for ``gluing'' silicon wafers together with a Self Assembled Monolayers (SAMs) based nanoglue are discussed, as are methods to enable its use with nonconforming wafers. Results of bond strength measurements as a function of temperature and process will be presented. Surface area bonded is characterized by infrared (IR) imaging. We will also present a method of inducing self-alignment between whole silicon wafers with micrometer precision. This represents a qualitative departure from alignment of millimeter-sized object as has been previously demonstrated. Self-alignment is induced by creating hydrophilic and hydrophobic regions on the wafers and using capillary forces of water in these regions to force the wafers to align with little to no outside influence. Results are characterized by IR imaging. ...
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm nano particles, which will make filter mass based PM control very challenging in the near future. One result was that gravimetric PM emission could ...
2006-10-15
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Beside traditional applications of refractory metals, e.g. in high temperature furnace construction, lighting or glass industry, one of the most important molybdenum products nowadays are large plates which are frequently used as targets for the sputtering of molybdenum layers in thin-film transistor liquid crystal displays. For the hot rolling of the sintered pre-material, the control over the recovery and recrystallization behavior is of particular importance. Molybdenum tends to a very recovery controlled behavior during hot deformation, at which the dislocations arrange into subcell boundaries instantaneously. These pronounced recovery processes seem to consume a large amount of the stored deformation energy for the actual recrystallization. On the other hand, recovery provides the future recrystallization nuclei. For a comprehensive characterization of these microstructural processes, electron microscopy appears to be the most proper ...
2011-07-15
Optical and structural properties of Ge films from ion-assisted deposition
International Nuclear Information System (INIS)
The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this ...
2008-11-28
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated ...
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
Using Gammasphere data on prompt gamma rays from spontaneous fission of 252Cf, we propose energy-level schemes for 110,111,112, & 113Rh (Z=45). The fission-gamma data complement earlier studies of others on beta decay of fission products in that prompt fission gammas mainly populate yrast or near-yrast levels, while beta decay populates lower-spin levels. For the odd-A rhodium nuclei studied here, their ground bands and collective sidebands are compared with model calculations using triaxial-shaped nucleus with one odd quasi-proton. The energies and E2 transition rates are best fit by a shape slightly to the prolate side of maximum triaxiality, namely, gamma = 28 deg. The model calculations also show a K=1/2+ band with energies not in good agreement with a corresponding experimental band. The experimental 1/2+ band is regarded as an intruder band from a prolate-driving proton ...
2003-08-19
Energy Technology Data Exchange (ETDEWEB)
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines ...
1993-03-01
International Nuclear Information System (INIS)
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The ...
An Effective Method of Image Retrieval using Image Mining Techniques
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
2010-01-01
International Nuclear Information System (INIS)
The detection of foot-and-mouth disease (FMD) virus from various kinds of field samples (tissue extract and cell culture isolate) was studied using the polymerase chain reaction (PCR) technique. The gene selected for diagnosis was the polymerase gene and an amplification target product of 454 bp in length was produced using AP5/AP6 primer sets. The PCR product was further examined by NcoI endonuclease digestion. The presence of the internal restriction site was confirmed by demonstration of two small fragments of 330 bp and 124 bp in length. Forty-nine samples that gave positive and negative results by ELISA typing and were positive by the PCR test were tested by NcoI digestion to confirm the results. About 10% of PCR products could not be confirmed by the method. Furthermore the FMD RNA polymerase gene could be detected by the PCR method in samples negative in both ELISA typing and the virus isolation test. A total of 23 samples were examined and compared after each stage of the ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
High-spin states in the neutron-rich nuclei {sup 172,173}Yb have been populated in a {sup 170}Er({sup 7}Li,(p,d,t)xn) incomplete-fusion reaction and the emitted {gamma}-radiation was detected with the GASP array. The signature partners of the 7/2{sup +}[633] rotational band of the odd-N {sup 173}Yb isotope have been newly established and were observed up to spin values of (45/2{sup +}) and (43/2{sup +}), respectively. The ground-state band of the even-even nucleus {sup 172}Yb has been observed up to a spin value of (22{sup +}). No band crossings were found in these bands. To explain this observation, it is proposed that the static pair field is absent, considering that the neutron odd-even mass differences reach for these nuclei very small values and that the band crossing is absent in cranked shell modell calculations without pairing. The results indicate, however, that strong ...
2005-10-01
The visible absorption spectra of 1,4-(dihydroxy)-9,10-anthraquinone and of Co(II), Ni(II), Cu(II) and Zn(II) chelates have been studied in different organic solvents. This system provides a model for the anthracycline antibiotics and their metal chelates. The band structure of the spectrum has been determined using the second and fourth derivatives of the spectrum. The visible absorption band of the parent molecule can be assigned to a single electronic state with a reduced dipole moment in the excited state; structure in this band is ascribed to two overlapping vibrational progressions. In contrast, the dianion (hydroxy protons removed) shows a single electronic state with an increased dipole moment in the excited state; structure in this band can be assigned to a single vibrational progression. All of the metal chelates show spectra which are similar in appearance to that of the dianion although the ...
1990-08-15
Geology and coal resources of the Cadomin mapsheet (83F/3), Alberta
Energy Technology Data Exchange (ETDEWEB)
Cretaceous and Tertiary strata are known from outcrop in the northeast part of the area, while older rocks are presented in the southwest. The major structures are, from north to south: the Pedley Thrust, Coalspur Triangle Zone (formerly called Coalspur Anticline), Entrance Syncline, Mercoal Thrust, Brazeau Flats, Brazeau Thrust, Brazeau Syncline, Grave Flats Thrust, Cadomin syncline and Nikanassin Thrust. The economic coal seams of the Tertiary Coalspur Formation are of high volatile C rank and are present in three parallel bands in the Entrance Syncline and Coalspur Triangle Zone, where they have been mined extensively in the past. The Mercoal band is the southernmost and dips about 30[degree] to the northeast. The Coalspur band is in the middle and dips generally to the southwest. The Robb band is the northernmost band, contains northeast dipping strata and is less deformed than ...
1993-01-01
International Nuclear Information System (INIS)
Energy band diagrams of LaCuOCh (Ch = S, Se and Te) were calculated by a full-potential linearized augmented plane-wave method. The calculations, based on the local density approximation with/without an on-site Coulomb repulsion parameter, were to examine the energy levels of La 4f states. The results of the calculations showed that the on-site correlation parameter is necessary for evaluating the energy levels of La 4f states appropriately. The calculations for LaCuOCh with the on-site correlation parameter revealed that LaCuOS and LaCuOSe have almost the same energy band structure with a direct allowed-type band gap, while LaCuOTe has significantly different conduction band structure that exhibits an indirect-type band gap. This difference in electronic structure between LaCuOCh (Ch = S, Se and Te) is consistent with the observed optical properties of these materials.
2004-07-21
Alignments, additivity, and signature inversion in odd-odd "1"7"0Ta: A comprehensive high-spin study
International Nuclear Information System (INIS)
High-spin states (I < or approx. 50(#Planck constant#/2#pi#)) of the odd-odd nucleus "1"7"0Ta have been investigated with the "1"2"4Sn("5"1V,5n) reaction. The resolving power of Gammasphere has allowed for the observation of eleven rotational bands (eight of which are new) and over 430 transitions (#approx#350 of which are new) in this nucleus. Many interband transitions have been observed such that the relative spins and excitation energies of the 11 bands have been established. This is an unusual circumstance in an odd-odd study. Configurations have been assigned to most of these bands based upon features such as alignment properties, band crossings, B(M1)/B(E2) ratios, and the additivity of Routhians. A systematic study of the frequency at which normal signature ordering occurs in the #pi#h_9_/_2#nu#i_1_3_/_2 band has been performed and it is found that its trend is opposite ...
2010-06-01
Vapor fraction measurements in a steam-water duct at atmospheric pressure using neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.
1994-11-11
Surface characteristics and overlaying properties of flat-pressed wood plastic composites
British Library Electronic Table of Contents (United Kingdom)
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
2011-01-01
Smoothing of laser energy deposition by gas jets
International Nuclear Information System (INIS)
Smoothing of laser beam non-uniformities using gas jets has been studied. The experiment has been performed with the PALS (Prague Asterix Laser System) laser working at 0.44 ?m with an intensity of about 1015 W/cm2. The laser beam has been split in two by a prism thus creating an artificial large-scale non-uniformity (? 90 ?m). We recorded time resolved and static images of laser-gas jet interaction with and without an Al target. Multi 1-dimensional and 2-dimensional simulations show that such interaction acts redistributing the over-intensities over larger surface. This effect has to be attributed to ionization processes with consequent laser beam refraction. Results show that Argon gas jet produces a strong refraction of the laser beam thus strongly reducing the initial two spots separation. (authors)
2009-08-01
STAR: a local network system for real-time management of imagery data
Energy Technology Data Exchange (ETDEWEB)
Overall architecture of a local computer network, STAR, is described. The objective is to accomplish a cost-effective system which provides multiple users a real-time service of manipulating very large volume imagery information and data. STAR consists of a reconfigurable communication subnet (starnet), heterogeneous resource units, and distributed-control software entities. Architectural aspects of a fault-tolerant communication subnet, distributed database management, and a distributed scheduling strategy for configuring desirable computation topology are exploited. A model for comparing cost-effectiveness among starnet, crossbar, and multiple buses is included. It is concluded that starnet outperforms the other two when the number of units to be connected is larger than 64. This project serves as a research tool for using current and projected technology to innovate better schemes for parallel image processing. 30 references.
1982-10-01
International Nuclear Information System (INIS)
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
2004-10-15
British Library Electronic Table of Contents (United Kingdom)
Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)
2010-07-15
Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction
International Nuclear Information System (INIS)
An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.
2005-04-09
Monitoring urban land cover and vegetation change by multi-temporal remote sensing information
British Library Electronic Table of Contents (United Kingdom)
In order to analyze changes in human settlement in Xuzhou city during the past 20 years, changes in land cover and vegetation were investigated based on multi-temporal remote sensing Landsat TM images. We developed a hierarchical classifier system that uses different feature inputs for specific classes and conducted a classification post-processing approach to improve its accuracy. From our statistical analysis of changes in urban land cover from 1987 to 2007, we conclude that built-up land areas have obviously increased, while farmland has seen in a continuous loss due to urban growth and human activities. A NDVI difference approach was used to extract information on changes in vegetation. A false change information elimination approach was developed based on prior knowledge and statistic...
2010-01-01
We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.
2009-01-01
MAGIC Telescope observations of high energy gamma-rays from globular cluster M13
Energy Technology Data Exchange (ETDEWEB)
Globular clusters are quite compact (size {proportional_to}10 pc) objects distributed spherically around the galaxy. They contain about 10{sup 5}-10{sup 6} mostly old stars. The number of millisecond pulsars in typical globular cluster is expected to be large (of the order of 100). We investigate the possible mechanism of production of high energy gamma-rays in those objects. Part of the wind energy of pulsars (energy conversion factor) is converted into relativistic leptons. Those leptons can upscatter in inverse Compton process low energy starlight and CMB photons and produce gamma-rays. MAGIC is an Imaging Atmospheric Cerenkov Telescopes located at Canary island of La Palma. We present results and discussion of the MAGIC observations of globular cluster M13.
2008-07-01
Kinetics of gypsum crystal growth on a reverse osmosis membrane
British Library Electronic Table of Contents (United Kingdom)
The development of calcium sulfate dihydrate (gypsum) mineral scale in reverse osmosis (RO) membrane desalting was investigated by direct real-time observation of crystal growth. Gypsum scaling studies were conducted in a specially modified plate-and-frame reverse osmosis cell fitted with an optical window, with dark-field membrane lighting arrangement within the membrane cell to enhance crystal boundaries and allow recording of digital surface images magnified through an optical microscope. The evolution of the surface number density (SND) of gypsum crystals resembled a sigmoidal population growth process with an increasing rate of crystal formation at higher solution supersaturation (with respect to gypsum) at the membrane surface. The rate of formation of new crystals declined as the su...
2008-01-01
International Nuclear Information System (INIS)
Pd was deposited onto Si (111) 7x7 surface at approximately 700 K inside an ultrahigh vacuum transmission electron microscope. Plan-viewed transmission electron microscopy (TEM) observation indicated that the islands have two kinds of shapes, round and rectangular (one-dimensional) ones. In a diffraction pattern for the rectangular islands, extra spots along the <110> direction of the Si surface, spacing of which is 1/8 times as long as that of Si (220) spots, were seen. A high resolution TEM image showed the corresponding superstructure in the rectangular islands. In situ observation of the growing process of the rectangular islands showed repeat of introduction and relief of strains during the growth, suggesting that such superstructure would be constructed by stacking compositionally different phases or introducing defects so that the periodically maximized strain is relieved.
2003-01-22
Gravity Dual for a Model of Perception
One of the salient features of human perception is its invariance under dilatation in addition to the Euclidean group, but its non-invariance under special conformal transformation. We investigate a holographic approach to the information processing in image discrimination with this feature. We claim that a strongly coupled analogue of the statistical model proposed by Bialek and Zee can be holographically realized in scale invariant but non-conformal Euclidean geometries. We identify the Bayesian probability distribution of our generalized Bialek-Zee model with the GKPW partition function of the dual gravitational system. We provide a concrete example of the geometric configuration based on a vector condensation model coupled with the Euclidean Einstein-Hilbert action. From the proposed geometry, we study sample correlation functions to compute the Bayesian probability distribution.
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
The approval (2003) and enforcement (2005) of a smoking ban in Italy have been viewed by many as an unexpectedly successful example of policy change. The present paper, by applying a processualist approach, concentrates on two policy cycles between 2000 and 2005. These had opposing outcomes: an incomplete decisional stage and an authoritative decision, enforced two years later. Through the analysis of the different phases of agenda setting, alternative specification and decision making, we have compared the quality of participation of policy entrepreneurs in the two cycles, their political strategies and, in these, the relevance of issue image. The case allows us to direct the attention of scholars and practitioners to an early phase of the policy implementation process - which we have nam...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Petrographical analysis is a microscopical analytical tool which allows definition of the exact nature of the components of different concrete mixes, as well as definition of internal structures and alteration processes. In order to improve the precision and the swiftness of the petrographical analysis, an automated image analysis system has been developed. In the next stage of this study, which consisted in the testing of new concrete mixes containing fluidised bed ashes, petrography has been used, not only to identify the nature of the mix components, but also assess the behaviour of these new concrete mixes when exposed to aggressive conditions.
1997-11-01
Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...
2008-01-01
Biopolymer system for permeability modification in porous media
Energy Technology Data Exchange (ETDEWEB)
New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...
1995-12-31
Automated three-dimensional X-ray analysis using a dual-beam FIB
International Nuclear Information System (INIS)
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
2007-08-01
British Library Electronic Table of Contents (United Kingdom)
Root growth is a highly dynamic process influenced by genetic background and environment. This paper reports the development of R scripts that enable root growth kinematic analysis that complements a new motion analysis tool: PlantVis. Root growth of Arabidopsis thaliana expressing a plasma membrane targeted GFP (C24 and Columbia 35S:LTI6b-EGFP) was imaged using time-lapse confocal laser scanning microscopy. Displacement of individual pixels in the time-lapse sequences was estimated automatically by PlantVis, producing dense motion vector fields. R scripts were developed to extract kinematic growth parameters and report displacement to ?0.1 pixel. In contrast to other currently available tools, Plantvis-R delivered root velocity profiles without interpolation or averaging across the root s...
2011-01-01
Application of digital radiography to diagnosis of laryngeal diseases
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...
1986-01-01
Heterogeneous anisotropic diffusion problems arise in the various areas of science and engineering including plasma physics, petroleum engineering, and image processing. Standard numerical methods can produce spurious oscillations when they are used to solve those problems. A common approach to avoid this difficulty is to design a proper numerical scheme and/or a proper mesh so that the numerical solution validates the discrete counterpart (DMP) of the maximum principle satisfied by the continuous solution. A well known mesh condition for the DMP satisfaction by the linear finite element solution of isotropic diffusion problems is the non-obtuse angle condition that requires the dihedral angles of mesh elements to be non-obtuse. In this paper, a generalization of the condition, the so-called anisotropic non-obtuse angle condition, is developed for the finite element solution of heterogeneous anisotropic diffusion problems. The new condition is ...
2010-01-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.
2003-06-01
A playmate robot system for playing the rock-paper-scissors game with humans
British Library Electronic Table of Contents (United Kingdom)
We have developed a playmate robot system for playing the rock-paper-scissors game with humans. The playmate robot recognizes the hand motions of a human using image processing without attaching any additional units to the human. The playmate robot system consists of three parts: a game management part, a hand motion recognition part, and a robot hand control part. The system functions as follows. (1) Before the game is played, the game management part decides on the motion of the robot hand from amongst rock, paper, and scissors. After the game is played, the robot develops a reaction using speech and facial expressions depending on the result of the game. (2) The hand motion recognition part recognizes the hand motion of the human. It does not use any additional units on the human?s body...
2011-01-01
High power evaluation of X-band high power loads
Several types of X-band high power loads developed for several tens of MW range were designed, fabricated and used for high power tests at X-band facility of KEK. Some of them have been used for many years and few units showed possible deterioration of RF performance. Recently revised-design loads were made by CERN and the high power evaluation was performed at KEK. In this paper, the main requirements are recalled, together with the design features. The high power test results are analysed and presented
2010-01-01
Electronic structure and properties of boron phosphide and boron arsenide
International Nuclear Information System (INIS)
The composite wave variational version of the APW (augmented plane wave) method is used to obtain the electronic band structure of the compounds boron phosphide and boron arsenide at the high symmetry points #GAMMA#, X, and L. The tight binding interpolation scheme of Slater and Koster is used to calculate the rest of the band structure. The results show that both these materials are indirect band gap semiconductors. The density of states, and the imaginary part of the dielectric constant is also calculated. The theoretical results are compared with the reported experimental and theoretical data. (author).
Bound and resonant surface states at the (110) surfaces of AlSb, AlAs, and AlP
Energy Technology Data Exchange (ETDEWEB)
The dispersion curves E(k-bar) have been calculated for bound and resonant (110) surface states of AlSb, AlAs, and AlP. AlSb is predicted to have no surface states within the bulk fundamental band gap, but AlAs and AlP are predicted to have surface state band minima which are very near the conduction band edge, and could lie either within the gap or immediately above the edge.
1982-07-01
British Library Electronic Table of Contents (United Kingdom)
We have measured the frequency-dependent dielectric function of semi-crystalline polybutylene terephthalate (PBT) in the terahertz region between 100?GHz and approximately 2.8?THz. A characteristic band is observed around 2.38?THz. The intensity of this band is a good indicator of the degree of crystallinity of the different samples. A potential assignment of this band is proposed, based on the comparison with spectroscopic data of the structurally very similar polyethylene terephtalate (PET). Furthermore, the frequency-dependent index of refraction of PBT reveals more insight about the morphology and different thermal history of the samples under investigation.
2011-01-01
Tony Curtis obituary | Film | The Guardian
... Second, in drag as a member of the all-girl band which provides his camouflage. And last as a fake oil millionaire - out to seduce Marilyn - played as a wonderful homage to Cary Grant. \\
The Current Status of Russian/CIS Communication Satellites
... 4302, and to the Office of Management and Budget, Paper-work ... link coverage areas, so it is possible to receive your own ... mestic Ku-band satellite. ...
1994-09-01
International Nuclear Information System (INIS)
The structural, electronic and optical properties of ZnX and CdX (X = Se, Te and S) are studied using density functional theory by the Wien2k package. The energy band gap, real and imaginary parts of the dielectric function, energy loss function, optical absorption coefficient and reflectivity spectra of these compounds are calculated. The Engel-Vosko approach improves the energy band gaps of ZnX and CdX compounds. The calculated optical parameters are in good agreement with available experimental results, particularly in the Engel-Vosko approach. Furthermore the effect of hydrostatic pressure on the energy band gap, the real and imaginary parts of the dielectric function of these compounds is studied. The first and second order pressure coefficient for the energy band gaps, the static dielectric function and the static reflectivity spectra are calculated.
2010-09-03
Strongly perturbed rotational bands in the "1"8"7Ir and "1"8"9Ir
International Nuclear Information System (INIS)
... alpha beams energy-level transitions gamma spectra iridium 187 iridium 189
1973-06-19
Limitations of silicon devices for quantum computing
Energy Technology Data Exchange (ETDEWEB)
There is considerable interest in the use of silicon devices as qubits for quantum computing. The existence of nuclear spin in a silicon isotope and the complex band structure of silicon are unfavourable for this application of silicon devices. (viewpoint)
2004-04-28
Integrated Optics Interdigitated-Electrode Switches
... thus can function as switches -6 ... Akkari, "Optical Channel Waveguide Switch and Coupler ... Wide-Band Guided Wave Acousto-Optic Bragg Diffraction ...
1989-12-31
Gadolinium electronic band structure: augmented plane wave calculation
International Nuclear Information System (INIS)
Augmented plane wave calculation of gadolinium electronic structure crystallized in a hexagonal close-packed lattice is carried out.
International Nuclear Information System (INIS)
The self-consistent-pseudopotential method is applied to the A-15 compounds Nb_3Ge and Nb_3Al. The Fermi energy is found to lie in a region of very flat bands having a bonding character along the Nb chains. Comparison with the band structures of the (nonexistent) A-15 materials Nb_3Nb and Nb_3/sup asterisk/ (chains only) suggest that the p states on the Ge and Al atoms are instrumental in determining the position of the Fermi level. There is little evidence for rigid-band behavior in the Nb_3Al/sub x/Ge/sub 1-x/ system. Studies of the effects of chain dimerization in Nb_3Ge suggest that states at R and M are more likely candidates to participate in structural transitions than states at GAMMA or X.
International Nuclear Information System (INIS)
The band offsets and subband levels in a double quantum well layer for a 660 nm-Ga_0_._4In_0_._6P/(Al_0_._5Ga_0_._5)_0_._5In_0_._5P quantum well laser are determined by photoreflectance using a 410 nm InGaN laser with current modulation at room temperature. The subband levels are analyzed by numerical calculation of the Schroedinger equation for the layer structure by varying the conduction band offset and compared with the measured photoreflectance spectra. The conduction band offset ratio is determined to be 0.5+0.03. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2009-06-01
Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and ...
1987-05-01
Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and ...
1985-01-01
CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...
Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...
CBSD Version 2 Component Models of the IR Celestial ...
... 1-sigma ZOHF pixel-to-plxel statistical fluctuations ... Spatial frequency filtering shows distinct bands, but miss ... LOS emissivity at the point of closest ...
1990-12-07
Broad-band hard X-ray reflectors
DEFF Research Database (Denmark)
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
1997-01-01
Are transition nuclei "1"8"9Ir and "1"8"7Ir triaxial
International Nuclear Information System (INIS)
... band theory excited states iridium 187 iridium 189 beta decay radioisotopes
1975-06-30
Acoustic band gaps in arrays of neutral inclusions
British Library Electronic Table of Contents (United Kingdom)
We analyse numerically the acoustic stop band properties of an array of orthotropic coated cylinders whose elastic parameters are deduced from a geometric transform [H. Chen, C.T. Chan, Acoustic cloaking in three dimensions using acoustic metamaterials, Appl. Phys. Lett. 91 (2007) 183518]. We find that whereas a single coated inclusion is acoustically neutral at any frequency, an array of them might display some stop bands. More precisely, an array of freely vibrating coated voids is always neutral, whereas an array of clamped coated inclusions might display a zero frequency stop band. Interestingly, an array of radially symmetric coated inclusions behaves as local Helmholtz resonators, for which the eigenfield within each cloak is obtained in closed form, leading to a frequency estimate a...
2010-01-01
Ab initio calculations of the electronic structure of the silver palladium oxide Ag_2PdO_2
International Nuclear Information System (INIS)
Ab initio calculations of the electronic structure were performed for the silver palladium oxide, Ag_2PdO_2, by the full potential mixed linearized augmented plane wave and augmented plane wave plus local orbitals method (mixed LAPW/APW+lo) within the density functional theory and using the generalized gradient approximation (GGA96, Phys. Rev. Lett. 77 (1996) 3865) for the exchange-correlation potential. The lattice parameters were calculated from the ground-state total energy versus volume curve, and are in good agreement with the available experimental results. Our calculations of band structure predicted that the compound Ag_2PdO_2 has indirect band gap, and the Pd 4d states strongly hybridize with the O 2p states all over the valence bands and conduction bands. The valence bands are composed mainly of Ag, Pd 4d states and O 2p states, while the conduction ...
2003-09-01
Energy Technology Data Exchange (ETDEWEB)
Hyaluronate (HA) distribution patterns were examined in the cranial mesenchyme underlying the mesencephalic neural folds of mouse embryos maintained in roller tube culture. Using standard image-processing techniques, the digitized images of Alcian blue-stained or 3H-glucosamine-labeled sections digested with an enzyme specific for HA, were subtracted from adjacent, undigested sections. The resultant difference picture images (DPI) accurately depicted the distribution of stained or labeled HA within the cranial mesenchyme. 3H-glucosamine-labeled HA was distributed uniformly throughout the cranial mesenchyme as 12, 18, and 24 hr of culture. By contrast, the mesenchyme was uniformly stained with Alcian blue at 12 hr, but stain intensity decreased in the central regions of the mesenchyme at 18 and 24 hr. HA distribution patterns were also examined in the cranial mesenchyme of embryos cultured in the presence of ...
1990-06-01
Energy Technology Data Exchange (ETDEWEB)
The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas were classified into ...
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the ...
2001-12-01
International Nuclear Information System (INIS)
Neurotensin (NT) and its high affinity receptor (NTR1) are involved in several neoplastic processes. Thus, NT-based radiopharmaceuticals are potential tracers for targeted diagnosis and therapy of NTR-positive tumours. A new analogue based on NT(8-13), NT-XIX, with the three enzymatic cleavage sites stabilised, was synthesised and tested. The synthesis was performed by Boc strategy. Labelling with "9"9"mTc/"1"8"8Re was performed using the tricarbonyl technique. Metabolic stability was tested in vitro and in vivo. NT-XIX was further characterised in vitro in HT-29 cells and in vivo in nude mice with HT-29 xenografts. NT-XIX showed much longer half-lives than non-stabilised analogues. Binding to NTR1 was highly specific, although the affinity was lower than that of natural NT. Bound activity rapidly internalised into HT-29 cells and 50% remained trapped after 24 h. In the time-course biodistribution, the highest uptake was found in the tumour at all p.i. times. In ...
2009-01-01
Thermoluminescence emission of X-irradiated Eu{sup 2+} doped KBr single crystals
Energy Technology Data Exchange (ETDEWEB)
In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with {approx} 50 ppm of Eu{sup 2+} ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at {approx} 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu{sup 2+} impurity acts as an electron trap during the irradiation process and that the radiation ...
1996-12-31
Thermoluminescence emission of X-irradiated Eu"2"+ doped KBr single crystals
International Nuclear Information System (INIS)
In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with #approx# 50 ppm of Eu"2"+ ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at #approx# 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu"2"+ impurity acts as an electron trap during the irradiation process and that the radiation induced ...
The Stefan Problem Revisited: A Continuum Model of Frost Heave
The classical Stefan problem describes the motion of a solidification front through a uniform half-space in response to a step change in temperature on its boundary. The predictions of such a model can be applied quite accurately to the freezing of water in a porous medium so long as the pore geometry remains unaltered by the passing solidification front. It is observed, however, that in fine-grained porous media, ice has a tendency to form in segregated horizontal bands, known as ice lenses, that disrupt the regular pattern of heat flow through their enhanced consumption of latent heat. This process, known as frost heave, causes significant ground deformation in regions subject to prolonged freezing, and is one of the most important weathering processes in polar and alpine regions. Recent improvements to our understanding of the mechanics of ice lens nucleation and growth are applied here to predict the conditions and ...
2005-12-01
Solid state electrochemistry and spectroelectrochemistry of poly(arylene bisimide-alt-oligoether)s
International Nuclear Information System (INIS)
Two electroactive polymeric arylene bisimides, namely poly[(4,7,10-trioxatrideca-1,13-diyl)-(1,4,5,8-naphthalenetetracarboxylic bisimide-N,N'-diyl)] and its perylene analogue - poly[(4,7,10-trioxatrideca-1,13-diyl)-(3,4,9,10-perylenetetracarboxylic bisimide-N,N'-diyl)] have been synthesized and studied by cyclic voltammetry, UV-vis-NIR as well as Raman spectroeletrochemistry. Contrary to low molecular weight arylene bisimides, which show a clear two electron, double-step electrochemical reduction (neutral form to radical anion and from radical anion to dianion), in the synthesized polymers multielectron transfers are observed, accompanied with a strong electrochromic effect. However, as probed by cyclic voltammetry, their first reduction step is retarded and covers a wider potential range. We attribute this effect to macromolecular nature of the compounds being reduced and their structural inhomogeneity caused by ?-stacking induced nanoaggregation of bisimide segments of the polymer ...
2011-04-01
Radioisotope imaging of brain tumors in two rhesus monkeys. Final report
Energy Technology Data Exchange (ETDEWEB)
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
1988-04-01
Fracture imaging with converted elastic waves
Energy Technology Data Exchange (ETDEWEB)
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
2001-05-29
Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei ...
1999-10-01
Reduced boron diffusion under interstitial injection in fluorine implanted silicon
International Nuclear Information System (INIS)
Point defect injection studies are performed to investigate how fluorine implantation influences the diffusion of boron marker layers in both the vacancy-rich and interstitial-rich regions of the fluorine damage profile. A 185 keV, 2.3x10"1"5 cm"-"2 F"+ implant is made into silicon samples containing multiple boron marker layers and rapid thermal annealing is performed at 1000 deg. C for times of 15-120 s. The boron and fluorine profiles are characterized by secondary ion mass spectroscopy and the defect structures by transmission electron microscopy (TEM). Fluorine implanted samples surprisingly show less boron diffusion under interstitial injection than those under inert anneal. This effect is particularly noticeable for boron marker layers located in the interstitial-rich region of the fluorine damage profile and for short anneal times (15 s). TEM images show a band of dislocation loops around the range of the fluorine implant and the ...
2007-12-01
Correction for loss of track density due to overlapping track on SSNTD
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This ...
1990-06-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
