It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).
It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...
We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.
A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imagingcalorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).
Researchers report results from the Low Energy Antiproton Experiment (LEAP), a balloon-borne instrument which was flown in August, 1987. They found a value of 4.2 by 10-6 for the antiproton to proton ratio in the energy range from 120 MeV to 600 MeV at the top of the atmosphere. In particular, this experiment places an upper limit on the flux almost an order of magnitude below the reported flux of Buffington et al. This upper limit allows us to place significant constraints on both the primordial black hole and weakly interacting Majorana Fermion hypothesis, as well as on the low energy processes in more conventional models of galactic cosmic ray antiproton production.
The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.
Satellite CMB anisotropy missions and new generation of balloon-borne and ground experiments, make use of complex multi-frequency instruments at the focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground contamination is minimum, it is extremely important to reach the best trade-off between the improvement of the angular resolution and the minimization of the straylight contamination mainly due to the Galactic emission. We focus here, as a working case, on the 30 and 100 GHz channels of the Planck Low Frequency Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic foreground components for a reference set of optical configurations. We show that it is possible to improve the angular resolution of 5-7% by keeping the overall GSC below the level of few microKelvin. A comparison between the level of straylight introduced by the different Galactic components for different beam regions is presented. Simple approximate ...
In the summer of 1980, a balloon-borne cosmic ray experiment reported the detection of 14 low energy antiprotons during an 18 hour flight. This measurement represented an antiproton intensity two orders of magnitude greater than that predicted by conventional theories. This surprising result triggered a flurry of papers theorizing the origin of these particles, including the prediction of domains of primary antimatter, and evidence for supersymmetric particle annihilation. Not until the summer of 1987 was a follow up experiment (PBAR) performed. The PBAR detector has both better resolution and a larger dynamic range in energy than the previous detector. It measured the energy spectrum of antiprotons in the 0.1-1.5 GeV kinetic energy range. The present work describes the instrument, the experiment, and the results. Our analysis of the PBAR data reveals no antiprotons in the energy range of 0.13-0.64 GeV and only one antiproton candidate for energies between 0.64 and ...
The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray experiments gathering data below a few g/cm{sup 2} ...
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...
Development of the Technology and Control of Electron-Beam Welding Procedure and Production of Full Scale Sector of Endcap CMS Hadron Calorimeter. Preparation for Mass Production.
The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.
A balloon-borne instrument has measured the cosmic-ray antiproton flux between 130 and 320 MeV and searched for antihelium between 130 and 370 MeV per nuclear. These particles were selected from the background of normal-matter cosmic rays by combining a selective trigger with a detailed spark chamber visualization of each recorded event. Antiprotons are identified by their characteristic annihilatin radiation. Residue from background processes meeting the selection criteria is small. The observed 14 antiprotons yield a measured differential flux of 1.7 +- 0.5 x 10/sup -4/ antiprotons m/sup -2/ sr/sup -1/ s/sup -1/ MeV/sup -1/ at the top of the atmosphere. The corresponding antiproton/proton ratio is 2.2 +- 0.6 x 10/sup -4/,, only slightly smaller than the ratio observed by other experiments at higher energies. Thus the antiprotons have a spectral shape similar to the protons, at least down to about 100 MeV. The expected flux of these particles can be calculated ...
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward ...
In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imagingcalorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.
A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imagingcalorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter ...
The condition for obtaining a calorimetric response linear with energy for hadronic showers and an energy resolution that improves as the incident energy increases is the equalization of the electromagnetic (e) and the hadronic (#pi#) signal responses. This equalization is obtained by exploiting a local hardening effect realized through the insertion of low-Z thin plates between the high-Z absorbers and the active material in a hadronic calorimeter with silicon readout. This effect, which allows the reduction of the calorimeter response to the electromagnetic component of the incoming hadronic showers, has been investigated for different low-Z materials. The relevance of some aspects of this study to the radiation hardness of the calorimeters is also addressed. (orig.).
In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of ...
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...
This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in between the combustion experiments was designed and found to be ...
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the ...
ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam tests performed at CERN in 1999, are also ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.
Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger ...
A prototype trumpet type nonimaging secondary concentrator was designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW{sub e} dish-Stirling system. A set of operational tests was carried out with a high temperature heat pipe receiver and gas-gap calorimeter. These tests have successfully alleviated any operational concerns about the effectiveness of active water cooling for such devices. The authors obtained over two full days of testing with the cavity receiver operating at its design temperature of 660 C while the trumpet throat temperature remained {approx_equal} or less than 100 C. In addition, these tests have shown that the thermal isolation of the trumpet from the hot receiver is very effective. Highly variable insolation, instabilities in the temperature controller on the calorimeter, and a poor match between the optical quality of the primary and the design of the trumpet have made detailed quantitative results ...
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger mode the ...
The thermodynamic properties of aqueous solutions containing ammonia and sour gases such as carbon dioxide, sulfur dioxide, or hydrogen sulfide must be known in many applications. A typical example is the cleaning of raw gases in power stations. The enthalpy changes upon partial evaporation of aqueous solutions containing ammonia and of aqueous solutions containing ammonia and carbon dioxide were measured at temperatures from 313 to 393 K with a thin film evaporator flow calorimeter. The molalities of ammonia and carbon dioxide entering the calorimeter ranged up to 12 and 6 mol/kg, respectively. The physicochemical model originally developed by Edwards et al. (1978) and further modified and extended by Kurz et al. (1995) to describe phase equilibria in aqueous systems containing ammonia and carbon dioxide is used to derive a predictive enthalpy model for this complex, chemical reactive system. Comparisons between the new experimental results ...
Energy expenditure (EE) of four adult men on a weight-maintenance diet was estimated by use of doubly labeled water, intake balance, and direct and indirect calorimetry. The doubly labeled water (2H218O) method was used to estimate free-living EE for 13 d. Metabolizable energy (ME) intake was used to estimate free-living EE for 1 wk. The subjects' 24-h EE was measured in a dual direct-indirect room calorimeter on 3 alternate days. Estimates of free-living EE as measured by ME intake and doubly labeled water indicate agreement between the two methods (mean difference +/- SEM, -1.04 +/- 0.63%). Measurements of EE with indirect and direct calorimetry are equivalent (mean difference 0.63 +/- 0.44%). The daily EE measured by doubly labeled water in these free-living adults over a 13-d period was 15.01% greater than the 24-h EE measured within the calorimeter.
Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.
Thermodynamic states encountered during combustion of Aluminum powder in Shock-Dispersed-Fuel (SDF) explosions were analyzed with the Cheetah code. Results are displayed in the Le Chatelier diagram: the locus of states of specific internal energy versus temperature. Accuracy of the results was confirmed by comparing the fuel and products curves with the heats of detonation and combustion, and species composition as measured in bomb calorimeter experiments. Results were fit with analytic functions u = f(T) suitable for specifying the thermodynamic properties required for gas-dynamic models of combustion in explosions.
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.
A search for monopoles and tachyons at ground level was carried out using an arrangement consisting of an ionization calorimeter and two hodoscope detectors. No clear evidence for these particles was obtained. The flux of monopoles with velocities beta approximately 0.01 is found to be less than 5.1 x 10 to the minus 13th power square centimeters s(-1) sr(-1) (95% cl.). The upper limit on the tachyon flux density is set as a 6 x 10 the minus 9th power particle/square centimeter event.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
Isobaric molar heat capacities of powder and microsphere form of Li2TiO3 (s) and powder form of LiAlO2 (s) and Li2ZrO3 (s) were measured using a heat flux type differential scanning calorimeter in the temperature range 320 - 870 K. Specific heat capacities of LiAlO2 (s) was found to be much larger compared to those of Li2TiO3 (s) and Li2ZrO3 (s). (author)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.
We have searched for neutron-antineutron oscillations using the 5.56 fiducial kiloton-year exposure of the Soudan 2 iron tracking calorimeter. We require candidate n-nbar occurrences to have .GE. 4 prongs (tracks and showers) and to have kinematics compatible with nbar-N annihilation within a nucleus. We observe five candidate events, with an estimated background from atmospheric neutrino and cosmic ray induced events of 4.5 \\pm 1.2 events. Previous experiments with smaller exposures observed no candidates, with estimated background rates similar to this experiment. We set a lifetime lower limit for oscillation time in iron: T_A(Fe) > 7.2x10^{31} years. The corresponding lower limit for oscillation of free neutrons is \\tau_{n-nbar} > 1.3x10^8 seconds.
This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy measurement of hadrons at CMS. The networks ...
Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...
Using EAS data from the EAS-EXC group (EAS plus hadronic calorimeter and nuclear emulsion-X chamber hybrid experiment) on Mount Chacaltaya during the 1990's the fractal properties of the energetic cosmic ray fluxes was investigated. A discrimination in the hadron content of the energetic primaries furnishes two different data samples, the total EAS fluxes and the hadron-less fluxes. The sidereal diurnal variation of the hadron-less EAS time variation shows values of 0.5% with a phase at about 2.29 hr sidereal time. With the help of the Crassberger Procaccia algorithm the fractal dimensions have been investigated of, on the one hand, the differences in arrival times of the hadron-less showers and on the other hand the EAS fluxes time series with an integration time of five min. The obtained fractal dimensions show inconclusive evidence of continuous chaotic component in the data samples investigated.
As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)
The flame retardancy of polybutylene terephthalate (PBT) was studied focusing on the effect of various oxides. Thermo-gravimetric analysis, pyrolysis/gas chromatography/mass spectrometry, and elemental analysis (EA) were used to analyze the flame retardancy, which were observed through the UL-test and a cone calorimeter. Many oxides influenced the flame retardancy and some of them could suppress the flammability of PBT. In particular, the blended-PBTs with ZnO and V2O5 accelerated the degradation and the edges of oxygen consumption were shorter than neat-PBT although the flammability became poorer. The quantitative analysis of the scission products and the results of EA showed that hydrolysis, successive dehydration, and other various reactions changed the scission route to generate less f...
As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...
Effect of Al and AlP particles on the microstructure of near eutectic Mn-Si alloy (Mn-30 wt.%Si) was studied by Electron Probe Micro-analyzer (EPMA) and Differential Scanning Calorimeter (DSC). Crystal lattice correspondence analyses show that both Al and AlP have good lattice matching coherence relationships with MnSi phase, and the addition of Al and AlP particles results in an abnormal eutectic structure, i.e. the eutectic constitution MnSi and Mn{sub 5}Si{sub 3} precipitate separately: MnSi precipitates firstly, and then the Mn{sub 5}Si{sub 3} phase.
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The present thesis presents two different aspects of my work in the L3 experiment, which are on one side the search for supersymmetric particles, the scalar leptons, in two different topologies 'electron + X + E' and '2 leptons + 2 photons + E', each of them being related to two theoretical SUSY models, m-SUGRA and GMSB. On the other side my work has been completed by the study of the BGO crystal electromagnetic calorimeter of L3, and the calibration of the electromagnetic calorimeter EGAP. After the essential motivations being reviewed, the production and disintegration modes are detailed concerning the scalar lepton sector at LEP. Then one presents the analysis techniques which I used to perform my selection, and also the results obtained from the data collected by L3 for center of mass energies between {radical} S =183 GeV and 202 GeV. The selection criteria that allow to isolate the events I looked for, ...
A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be achieved. Such beams are of interest for the study of material property changes from short-pulse high-energy depositions and for ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...
We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...
The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer of Al and metastable ...
The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to obtain smelted ulexite. (Author) 19 refs.
In an adiabatic low-pressure calorimeter, the temperature dependence of the standard molar heat capacity of paramagnetic dicarbonyl rhodium complex with o-semiquinone (CO){sub 2}Rh(SQ) has been determined in the range from T=(6 to 355)K mainly with an accuracy of about 0.3%. Over the ranges from T=(205 to 234) K, T=(266 to 315)K and T=(316 to 345)K physical transformations have been revealed and their enthalpies and entropies have been estimated. The experimental data were used to calculate the thermodynamic functions C{sub p,m}{sup o}/R,{delta}{sub 0}{sup T}H{sub m}{sup o}/(R.K),{delta}{sub 0}{sup T}S{sub m}{sup o}/R and {phi}{sub m}{sup o}={delta}{sub 0}{sup T}S{sub m}{sup o}-{delta}{sub 0}{sup T}H{sub m}{sup o}/T (where R is the universal gas constant) between T=(0 and 355)K. The fractal dimension D in the heat capacity function of the fractal variant of Debye heat capacity theory has been evaluated.
The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major modification of replacing the beamline-torus duct in its entirety. ...
We propose to investigate the in-medium properties of vector $\\omega$ mesons at the normal nuclear density in Ap(pA) collisions and at higher density in AA collisions at the ITEP accelerator facility TWAC. Using of the inverse Ap kinematics will permit us to study the $\\omega$ meson production in a wide momentum interval included the not yet explored range of small meson momenta relative to the projectile nuclei where the mass modification effect in nuclear matter is expected to be the strongest. Momentum dependence of the in-medium $\\omega$ meson width will be studied in the traditional pA kinematics. We intend to use the electromagnetic calorimeter for reconstruction of the $\\omega$ meson invariant mass by detecting photons from the $\\omega \\to \\pi^{0}\\gamma \\to 3\\gamma$ decay. The model calculations and simulations with RQMD generator show feasibility of the proposed experiment. Available now intensity of the ion beams provides a possibility to collect ...
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the SCSF-81 has been studied.
A thermal analyzer-differential scanning calorimeter-mass spectrometer (TG-DSC-MS) was used to study oxygen carriers (OC) for their potential use for the application of chemical looping combustion (CLC) to solid fuels. Reaction rates, changes in reaction rates with repeated oxidation-reductions, exothermic heats during oxidation, and the effect of changing reduction gas compositions were studied. Oxidation rates were greater than reduction rates and reaction rates were reproducible through multiple oxidation-reduction cycles except where agglomeration occurred with powders. Iron oxide (Fe{sub 2}O{sub 3} powder) and iron-based catalysts were found suitable for CLC of solid fuels having rapid reduction rates which increased with higher reducing gas concentrations. Fe{sub 2}O{sub 3} powder was used to oxidize a high carbon coal char in an inert gas removing 88% of the carbon from the char. Other properties such as cost and durability indicated iron oxide OCs potential ...
The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from $\\pi^{0}$ trigger at the same centrality class. Within the current ...
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the time scale of a ...
Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to study the heat ...
Enthalpy increment measurements on La{sub 2}Te{sub 3}O{sub 9}(s) and La{sub 2}Te{sub 4}O{sub 11}(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 360.70T + 0.00409T {sup 2} + 133.568 x 10{sup 5}/T - 149 923 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 3}O{sub 9} and H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 331.927T + 0.0549T {sup 2} + 29.3623 x 10{sup 5}/T - 114 587 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 4}O{sub 11}.
Enthalpy increment measurements on La_2Te_3O_9(s) and La_2Te_4O_1_1(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H"o(T) - H"o(298.15 K) (J mol"-"1) = 360.70T + 0.00409T "2 + 133.568 x 10"5/T - 149 923 (373 #<=# T (K) #<=# 936) for La_2Te_3O_9 and H"o(T) - H"o(298.15 K) (J mol"-"1) = 331.927T + 0.0549T "2 + 29.3623 x 10"5/T - 114 587 (373 #<=# T (K) #<=# 936) for La_2Te_4O_1_1.
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al{sub 2}O{sub 3} {times} H{sub 2}O), which dehydrated to alumina (Al{sub 2}O{sub 3}) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
ECAL Barrel (EB) As already mentioned in June, the Barrel ECAL is fully commissioned and routinely used during CRUZET runs. Good progress has been made in the last months to ensure a stable and fully reliable operation, in particular for the Trigger path. More details can be found in the DPG report in this bulletin. ECAL Endcaps (EE) In the June CMS bulletin, it had been announced that the Dee’s mechanical assembly had been finished end of May. However the electronics integration was still going on for the first Dee. The Summer has seen a spectacular breakthrough of the Endcap project. The electronics integration of Dee1 was completed early July, and this first Dee was transported to point 5 on July 8th. The completion of the three other Dees followed at a pace of one per week. In all cases the quality of the detector as measured in the assembly center was excellent, with all channels active and the expected noise performance (see ...
This report describes the combustion experiments performed using the SP Industry Calorimeter. In addition to measuring parameters such as heat release rate (HRR), mass loss rate, effective heat of combustion and smoke obscuration, considerable effort was put into the characterisation of the smoke gases in order to obtain a basis for evaluations of the toxic potency of the smoke. The materials studied were Nylon 66, polypropene, polystyrene (with and without fire retardant, respectively), PVC and chlorobenzene. A total of 19 large-scale, well ventilated combustions were carried out. The mass of sample burned ranged from 20 kg to 125 kg in an experiment. A procedure was designed for cleaning the smoke gas duct between experiments and was found to be effective. Measurements were carried out for the amounts of O{sub 2}, CO{sub 2}, CO, NO{sub x}, THC (unburned hydrocarbons), HCN, HCl, NH{sub 3} and individual organic compounds in the smoke. Adsorbents were used for the ...
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...
Apparent molar volumes V{sub phi} and apparent molar heat capacities C{sub p,phi} were determined for aqueous solutions of nickel(II) nitrate, copper(II) nitrate, and zinc(II) nitrate at molalities m=(0.01 to 0.5) mol {center_dot} kg{sup -1}, and at the pressure p=0.35 MPa. Solution densities obtained using a vibrating-tube densimeter at T=(278.15 to 368.15) K were used to calculate V{sub phi} values. Heat capacity measurements obtained with a twin fixed-cell, differential-output, power-compensating, temperature-scanning calorimeter at T=(278.15 to 393.15) K were used to calculate values of C{sub p,phi}. Our results were then fitted to functions of m and T and compared to literature values.
This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are used for charged particle identification (for e, {pi}, K, and ...
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available
Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.
BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available
Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.
The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.
Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.
/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.
A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.
This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.
Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.
VSP reverse-time migration is a well adaptable wave equation migration method. Its control equation not only describes all-direction propagation of seismic wave but also removes interbed multiples. Clearbout's image principle is generalized to determine image conditions, real VSP data are used to determine boundary condition, and two way reflection-free wave equation is solved by making reverse-time extrapolation. In each step of extrapolation, the migration value at relevant image point is obtained by using the image condition. The complete migration of a seismic section is achieved when reverse-time extrapolation reaches the minimum image time. In this paper it is proved theoretically and practically that this method is applicable to any velocity variation and makes the migrated section have both good resolution and high S/N ratio. Besides, this method results in high ...
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect ...
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean ...
Two peptide ligands conjugated adenine, [9-N-(tritylmercapto acetyl diglycyl aminoethyl) adenine, Tr-MAG_2-Ade] and [9-N-(tritylmercapto acetyl triglycyl aminoethyl) adenine, Tr-MAG3-Ade], are synthesized and labeled with "9"9"mTc by directly labeling method. The stability of "9"9"mTc-MAG_2- adenine and "9"9"mTc-MAG_3-adenine in vitro is measured. The uptake radios of tumor to muscle at 3h post-injection are 5.70 and 4.92, respectively. The biodistribution and scintigraphic imaging studies show that the two complexes have high localization in tumor and high contrasted tumor images can be obtained, which suggest their potential utility as tumor imaging agents. But the high radioactivity of abdomen could prevent the tumor imaging in this area. (author)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized ...
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to ...
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance ...
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a ...
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might ...
We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an ...
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI ...
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate ...
To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring enhancement were noted on delayed images. In HCC (n=37), 36 ...
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo ...
More than 660 synthetic aperture radar (SAR) images acquired over the southern Baltic Sea, the North Sea, and the Gulf of Lyon in the Mediterranean Sea by the Second European Remote Sensing Satellite (ERS-2) have been analyzed since December 1996 with respect to radar signatures of marine pollution and other phenomena causing similar signatures. First results of our analysis reveal that the seas are most polluted along the main shipping routes. SAR images acquired during descending (morning) and ascending (evening) satellite passes show different percentages of oil pollution, because most of this pollution occurs during night time and is still visible on the SAR images acquired in the morning time. Moreover, we found a higher amount of oil spills on SAR images acquired during summer (April-September) than on SAR images acquired during winter (October-March). We attribute this ...
Internet bandwidth is in high demand, and one way that web sites lower the amount of bandwidth they use is by compressing their site's images. This lowers the amount of bandwidth used, and makes the site load much faster. There are of course many other useful applications for compressed images. Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in a bit-plane can be replaced with noise-like secret data without discernible loss in image quality. This is possible because the human eye, while very good at distinguishing anomalies in areas of homogenous texture, is bad at distinguishing anomalies in visually complex areas. However, BPCS is not a robust embedding scheme, and any lossy compression usually destroys the data. Wavelet ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) ...
Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip ...
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) ...
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After ...
A theoretical background of crosshole reflection imaging with pre stack, multi-mode reverse time migration has been investigated. The crosshole migration has been carried out by solving two-way scalar wave equation with finite difference approximation. The wave field extrapolation was performed backward in time, with the imaging condition applied at each extrapolation time step to create partial image of the reflector. The complete migrated image was obtained by adding all the partial images from each time step. With multi-component crosshole data available, it is possible to separate the recorded data into primary P- and S-wave field. Separating wave field before migration is helpful in enhancing migrated image quality since only one wave mode can be dealt at a time with the scalar wave equation. It is possible to migrate mixed-mode primary reflections(P-S and ...
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other ...
Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS ...
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, ...
In order to predict thermal hazards of high-energy materials, accurate kinetics constants must be determined. Predictions of thermal hazards for mixtures of high-energy materials require measurements on the mixtures, because interactions among components are common. A differential-scanning calorimeter (DSC) can be used to observe rate processes directly, and isothermal methods enable detection of mechanism changes. Rate-controlling processes will change as components of a mixture are depleted, and the correct depletion function must be identified for each specific stage of a complex process. A method for kinetics measurements on mixed explosives can be demonstrated with Composition B is an approximately 60/40 mixture of RDX and TNT, and is an important military explosive. Kinetics results indicate that the mator process is the decomposition of RDX in solution in TNT with a perturbation caused by interaction between the two components. It is concluded that a ...
Relative densities and relative massic heat capacities have been measured for aqueous solutions of Y(ClO_4)_3, Yb(ClO_4)_3, Dy(ClO_4)_3, and Sm(ClO_4)_3 at T=(288.15,298.15,313.15, and 328.15) K and p=0.1 MPa. These measurements were made in the concentration range 0.01624#<=#m/(mol#centre dot#kg"-"1)#<=#0.41822 using a Sodev 02D Vibrating Tube Densimeter and a Picker Microflow Calorimeter, respectively. To counter the potential effects of hydrolysis, aqueous solutions of the investigated salts were acidified with perchloric acid. After correcting for the presence of the acid, the measured properties were used to calculate apparent molar volumes and apparent molar heat capacities for solutions of the perchlorate salts in water. The calculated apparent molar properties were modeled at each investigated temperature using Pitzer ion interaction equations to produce estimates of apparent molar volumes and heat capacities at infinite dilution. In addition, the ...
Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF {sigma}(n,{gamma}) agrees within uncertainties with JENDL-3.3 and JEFF-3.1, except for a ...
Isobaric specific heat capacities were measured for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol within the temperature range from (284 to 353) K, and for 2-methyl-2-butanol in the (284 to 368) K temperature interval by means of a differential scanning calorimeter. The excess molar heat capacities were calculated from the experimental results. For the temperature range from (284 to 287) K, the excess molar heat capacity is S-shaped with negative values in the 2-methyl-2-butanol rich region and with small negative values at low alcohol concentrations at temperatures from (295 to 353) K. The excess molar heat capacities are positive for all compositions under test at temperatures from (288 to 294) K. The results are explained in terms of the influence of the molecular size and configuration of the alkanols on their self-association capability and of the change in molecular structure of the (2-methyl-2-butanol + heptane) mixtures. The differences between ...
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study ...
Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased systems. Rate expressions were derived and rate constants determined for both the ...
The aim of this work was to compare the electrochemical behaviors and safety performance of graphite and the lithium titanate spinel Li1.33Ti1.67O4 with half-cells versus Li metal. Their electrochemical properties in 1 M LiPF6/EC + DEC (1:1 w/w) or 1 M LiPF6/PC + DEC (1:1 w/w) at room and elevated temperatures (30 and 60 deg C) have been studied using galvanostatic cycling. At 30 deg C graphite has higher reversible capacity than Li1.33Ti1.67O4 when using the LiPF6/EC + DEC as electrolyte. At 60 deg C graphite declines in cell capacity yet Li1.33Ti1.67O4 remains almost unchanged. In a propylene carbonate (PC) containing electrolyte, graphite electrode exfoliates and loses its mechanical integrity while Li1.33Ti1.67O4 electrode is very stable. An accelerating rate calorimeter (ARC) and microcalorimeter have been used to compare the thermal stability of lithiated lithium titanate spinel and graphite. Results show that Li1.33Ti1.67O4 may be used as an alternative ...
The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation instead does not exist between the N_#gamma# parameter and the ...
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron ...
In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart ...
High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction ...
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction ...
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the ...
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the ...
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which ...
Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the ...
Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to ...
Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular ...
We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast ...
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the ...
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the ...
To determine clinical predictors and accuracy of {sup 123}I-FP-CIT SPECT imaging in the differentiation of drug-induced parkinsonism (DIP) and Parkinson's disease (PD). Several clinical features and {sup 123}I-FP-CIT SPECT images in 32 patients with DIP, 25 patients with PD unmasked by antidopaminergic drugs (PDu) and 22 patients with PD without a previous history of antidopaminergic treatment (PDc) were retrospectively evaluated. DIP and PD shared all clinical features except symmetry of parkinsonian signs which was more frequently observed in patients with DIP (46.9%) than in patients with PDu (16.0%, p<0.05) or PDc (4.5%, p<0.01). Qualitatively {sup 123}I-FP-CIT SPECT images were normal in 29 patients with DIP (90.6%) and abnormal in all patients with PD, and this imaging technique showed high levels of accuracy. DIP and PD are difficult to differentiate based on clinical ...
Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time ...
Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time ...
Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-value were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm{sup 2}, and apparent diffusion coefficients. (orig.)
We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.
We present a numerical method for computing diffusive transport on a surface derived from image data. Our underlying discretization method uses a Cartesian grid embedded boundary method for computing the volume transport in region consisting of all points a small distance from the surface. We obtain a representation of this region from image data using a front propagation computation based on level set methods for solving the Hamilton-Jacobi and eikonal equations. We demonstrate that the method is second-order accurate in space and time, and is capable of computing solutions on complex surface geometries obtained from image data of cells.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.
In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.
A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.
The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)
We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.
Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).
The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing cardiac sympathetic denervation without ...
Feb 25, 2008 ... In the two Landsat scenes shown above, the pattern of deforestation can be clearly discerned. Deep green in these images shows lush ...
Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
On April 20, 2010 the Deepwater Horizon offshore drilling rig located in the Gulf of Mexico experienced an explosion resulting in at least 11 deaths and creating ...
Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...
... rivers of the world, the Zaire is not an efficient transportation link because of many rapids and falls to negotiate between Kinshasa and the port city of Matadi. ...
... The variogram analysis of the high resolution imagery has shown that although more spatial scales have been identified than from the SPOT image ...
... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.
A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
Sep 28, 2011... to assess the application of high resolution imagery for burn severity mapping and to compare it to standard burn severity mapping methods. ...
Jan 4, 2004 ... By 11:30, imaging specialists had assembled a 360-degree panorama of ... engineers will conduct a comprehensive assessment of its health. ...
Non-linear optics encompasses a range of optical phenomena, including two- and three-photon fluorescence, second harmonic generation (SHG), sum frequency generation (SFG), difference frequency generation (DFG), third harmonic generation (THG), coherent anti-Stokes Raman scattering (CARS), and stimulated Raman scattering (SRS). The combined advantages of using these phenomena for imaging complex pharmaceutical systems include chemical and structural specificities, high optical spatial and temporal resolutions, no requirement for labels, and the ability to image in an aqueous environment. These features make such imaging well suited for a wide range of pharmaceutical and biopharmaceutical investigations, including material and dosage form characterisation, dosage form digestion and drug rele...
Nato SCI-12 on Camouflage Evaluation Workshop on Search and Target Acquisition The Netherlands, June 1999. Image Discrimination Models for Object Detection ...
Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a ...
The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the ...
Land cover change can be caused by human-induced activities and natural forces. Land cover change in watershed level has been a main concern for a long time in the world since watersheds play an important role in our life and environment. This paper is focused on how to apply Landsat Multi-Spectral Scanner (MSS) satellite image of 1973 and Landsat Thematic Mapper (TM) satellite image of 2001 to determine the land cover changes of coastal watersheds from 1973 to 2001. GIS and remote sensing are integrated to derive land cover information from Landsat satellite images of 1973 and 2001. The land cover classification is based on supervised classification method in remote sensing software ERDAS IMAGINE. Historical GIS data is used to replace the areas covered by clouds or shadows in the image o...
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
Rotatostereoradiographic (RSRG) images are displayed in an oscillating, rotational manner. While reviewing these rotating images, the radiologist may become psychologically irritated by the rotation. A rapidly rotating display of linear subjects gives one three-dimensional depth information. This three-dimensional sense is lost if the rotation speed is too slow. The authors of this paper determined the slowest possible rotating display speed that allows perception of three-dimensional depth information minimizing psychological irritation. In the RSRG device (Shimadzu ROTATO-360), an x-ray tube coupled with an image intensifier rotates through a 180 degrees arc in 1.8 or 2.25 seconds. Both rotation times could be doubled. The images were displayed at four different speeds, covering the 180 degrees arc in 1.8, 2.25, 3.6, and 4.5 seconds.
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.
In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
the picture will download the highest resolution version available. Supernovae in the Whirlpool Image Credit & Copyright: R Jay Gabany Explanation: Where do spiral galaxies keep...
Primates are remarkably good at recognizing objects. The level of performance of their visual system and its robustness to image degradations still surpasses the best computer vision systems despite...Full Text Available
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
Post-drive imaging included 360-degree view by the navigation camera and .... Sol 938: Opportunity completed another assessment of the clarity of the sky. ...