WorldWideScience
 
 
1

Transcatheter stent implantation to treat aortic coarctation in infancy.  

UK PubMed Central (United Kingdom)

A ten week old girl who had previously undergone a palliative procedure for the hypoplastic left heart syndrome had unrelieved aortic coarctation that did not respond to standard balloon dilatation....Full Text Available

1993-01-01

2

Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...

2011-01-01

3

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...

2000-09-01

4

Management of Concomitant Cancer and Abdominal Aortic Aneurysm  

UK PubMed Central (United Kingdom)

Background. The coexistence of neoplasm and abdominal aortic aneurysm (AAA) presents a real management challenge. This paper reviews the literature on the prevalence, diagnosis,...Full Text Available

5

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

6

Transforming growth factor-beta signaling in thoracic aortic aneurysm development: a paradox in pathogenesis  

UK PubMed Central (United Kingdom)

Thoracic aortic aneurysms (TAAs) are potentially devastating, and due to their asymptomatic behavior, pose a serious health risk characterized by the lack of medical treatment options and high...Full Text Available

2009-01-01

7

Stimulation of albumin endocytosis by cationized ferritin in cultured aortic smooth muscle cells.  

UK PubMed Central (United Kingdom)

Anionic microdomains within the aortic smooth muscle cell (SMC) surface glycocalyx represent a potential barrier to the endocytosis of anionic plasma proteins. Cultured SMCs exposed briefly to cationized...Full Text Available

1985-12-01

8

Radiographic monitoring of incidental abdominal aortic aneurysms: a retrospective population-based cohort study  

UK PubMed Central (United Kingdom)

BackgroundAn abdominal aortic aneurysm (AAA) that is identified when the abdomen is imaged for some other reason is known as an incidental AAA. No population-based studies have...Full Text Available

9

Progress in Treatment of Thoracoabdominal and Abdominal Aortic Aneurysms Involving Celiac, Superior Mesenteric, and Renal Arteries  

UK PubMed Central (United Kingdom)

This is a report of surgical treatment of thoracoabdominal aortic aneurysms and aneurysms of the abdominal aorta from which the visceral vessels arise during the 18 year period from April 5, 1960,...Full Text Available

1978-09-01

10

Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study  

UK PubMed Central (United Kingdom)

The aim of this study was to compare the hemodynamic and ventilatory effects of prolonged infrarenal aortic cross-clamping in pigs undergoing either laparotomy or laparoscopy. 18 pigs were used for...Full Text Available

2008-01-01

11

Neuronatin: A New Inflammation Gene Expressed on the Aortic Endothelium of Diabetic Mice  

UK PubMed Central (United Kingdom)

OBJECTIVE—Identification of arterial genes and pathways altered in obesity and diabetes.RESEARCH DESIGN AND METHODS—Aortic gene expression profiles of...Full Text Available

2008-10-01

12

Interventional management of tracheobronchial strictures  

UK PubMed Central (United Kingdom)

Tracheobronchial balloon dilation and stent placement have been well used in the treatment of patients with benign and/or malignant diseases. Balloon dilation is the first option in the treatment of...Full Text Available

2010-08-28

13

Coronary artery overexpansion increases neointimal hyperplasia after stent placement in a porcine model  

UK PubMed Central (United Kingdom)

ObjectiveTo determine if an aggressive approach to coronary revascularisation with oversized balloons is counterproductive, we studied the effect of increasing balloon‐to‐artery...Full Text Available

2007-12-01

14

Temporary endovascular control of a bleeding aortoenteric fistula by transcatheter coil embolization.  

Science.gov (United States)

A 67-year-old man presented with gastrointestinal bleeding resulting from a fistula between the aortic stump and the fourth part of the duodenum 14 months after an axillobifemoral bypass, graft excision, and aortic stump closure for aortic graft infection. The patient initially refused any attempt at definitive surgical treatment so coil embolization of the aortic stump was performed via a brachial approach. Coil embolization may be a useful adjunct in the management of such difficult problems. This approach may buy time and allow careful planning of a definitive treatment or may serve as a palliative procedure in inoperable patients. PMID:15947052

2005-06-01

15

Tracer distributions in the Tropical Lower Stratosphere.  

Environmental Research Database

DescriptionMeasurements of halocarbons (CFCs and other halogen-containing compounds) in the tropical stratosphere will be made from a long duration MIR balloon. The balloon and instruments are capable of flying for three or more weeks in which time they will circum-navigate the globe. As the balloon rises each morning and falls each evening, measurements of halocarbons will be made every few hundred meters between about 20 and 30 km. In total it is hoped that over 40 such vertical profiles will be obtained [continued...

2009-01-31

16

Analysis of current diffusive ballooning mode in tokamaks  

Energy Technology Data Exchange (ETDEWEB)

The effect of finite gyroradius on the current diffusive ballooning mode is examined. Starting from the reduced MHD equations including turbulent transports, coupling with drift motion and finite gyroradius effect of ions, we derive a ballooning mode equation with complex transport coefficients. The eigenfrequency, saturation level and thermal diffusivity are evaluated numerically from the marginal stability condition. Preliminary results of their parameter dependence is presented. (author)

1999-12-01

17

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ...

18

Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten  

Energy Technology Data Exchange (ETDEWEB)

On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

1990-09-01

19

Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)  

International Nuclear Information System (INIS)

The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation ...

2005-03-01

20

T lymphocytes in aortic and coronary intimas. Their potential role in atherogenesis.  

UK PubMed Central (United Kingdom)

In order to investigate the role of mononuclear cells in infiltrates during the initial stages of atherogenesis, the authors have studied by immunohistochemical methods the aortas and coronary vessels...Full Text Available

1988-02-01

 
 
 
 
21

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

22

Association Between Wasted Pressure Effort and Left Ventricular Hypertrophy in Hypertension: Influence of Arterial Wave Reflection  

British Library Electronic Table of Contents (United Kingdom)

BackgroundWave reflection during the systole increases left ventricular (LV) pressure, tension-time index (TTI) and myocardial oxygen requirement. The purpose of this study was to extract that component of extra myocardial oxygen requirement that is due to early systolic wave reflection, define it as wasted effort (?Ew), and examine its relationship to LV hypertrophy (LVH).MethodsRadial artery pressure waveforms were recorded using applanation tonometry and central aortic waveforms generated in 98 patients with untreated hypertension. Aortic augmentation index (AIa), wave reflection amplitude (i.e., aortic augmented pressure (AG)) and systolic duration (ED?Tr), ejection duration (ED) and round-trip travel time of the pressure wave (Tr) were calculated from the aortic waveform, a...

2008-01-01

23

Space Science - NASA Headquarters  

Science.gov (United States)

Canada will provide telescope baffles and fine error sensor assemblies. ..... ( Ongoing) Flight tests aboard sounding rockets and balloon planned for FY 1995. .... the effects of incoming energetic particles and solar radiation on the ...

24

Baldwin, Tony Marcel - Goddard Library Repository  

Science.gov (United States)

Schmidlin F, Morrison B, Baldwin T, Moore P, Northam E. NASA AFRICAN MONSOON MULTIDISCIPLINARY ANALYSES MISSION: BALLOON-BORNE RADIOSONDE RESULTS FROM CAPE ...

25

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a ...

2008-02-21

26

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

27

Evidence that cell surface heparan sulfate is involved in the high affinity thrombin binding to cultured porcine aortic endothelial cells.  

UK PubMed Central (United Kingdom)

It has been postulated that thrombin binds to endothelial cells through, at least in part, cell surface glycosaminoglycans such as heparan sulfate, which could serve as antithrombin cofactor on the...Full Text Available

1985-04-01

28

Effect of aortic valvular regurgitation upon the impedance cardiogram.  

UK PubMed Central (United Kingdom)

The first derivative thoracic impedance cardiogram, phonocardiogram, and electrocardiogram were recorded in three groups of 22 subjects each. In Group 1 (control), simultaneous impedance cardiogram,...Full Text Available

1978-09-01

29

Chylopericardium after cardiac surgery can be treated successfully by oral dietary manipulation: a case report  

UK PubMed Central (United Kingdom)

We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available

30

Both common and specialty mushrooms inhibit adhesion molecule expression and in vitro binding of monocytes to human aortic endothelial cells in a pro-inflammatory environment  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular disease (CVD) is a leading cause of mortality in the United States as well as globally. Epidemiological studies show that regular fruit and vegetable consumption...Full Text Available

31

Acute aortic thrombosis in patients receiving cisplatin-based chemotherapy  

UK PubMed Central (United Kingdom)

The increased risk of thrombosis in patients with active cancer has multiple causes. Acute thrombosis of the aorta is an exceedingly rare but potentially devastating complication in patients with cancer...Full Text Available

2011-04-01

32

Use of Balloon Enteroscopy in Preoperative Diagnosis of Neurofibromatosis-Associated Gastrointestinal Stromal Tumours of the Small Bowel: A Case Report  

UK PubMed Central (United Kingdom)

Neurofibromatosis type I (NF1) is one of the most common inheritable disorders and is associated with an increased risk of gastrointestinal stromal tumours (GISTs). However, the predominant location...Full Text Available

33

The Atmospheric Trace ... - NASA Langley Science Directorate  

Science.gov (United States)

Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...

34

Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size  

UK PubMed Central (United Kingdom)

BackgroundThere is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was...Full Text Available

2007-12-01

35

MHD equilibrium and stability in heliotron plasmas  

Energy Technology Data Exchange (ETDEWEB)

Recent topics in the theoretical magnetohydrodynamic (MHD) analysis in the heliotron configuration are overviewed. Particularly, properties of three-dimensional equilibria, stability boundary of the interchange mode, effects of the net toroidal current including the bootstrap current and the ballooning mode stability are focused. (author)

1999-09-01

36

Endovascular surgery for peripheral arterial occlusive disease. A critical review.  

UK PubMed Central (United Kingdom)

Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available

1992-07-01

37

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement  

UK PubMed Central (United Kingdom)

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where...Full Text Available

38

Behavioral Characteristics and Neural Mechanisms Mediating Performance in a Rodent Version of the Balloon Analog Risk Task  

UK PubMed Central (United Kingdom)

The tendency for some individuals to partake in high-risk behaviors (eg, substance abuse, gambling, risky sexual activities) is a matter of great public health concern, yet the characteristics and neural...Full Text Available

2010-07-01

39

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. ...

2000-09-01

40

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

 
 
 
 
41

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a ...

42

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

43

Winter study of power plant effects  

Energy Technology Data Exchange (ETDEWEB)

As a part of DOE's Meteorological Effects of Thermal Energy Releases (METER) program a field study was undertaken at the Bowen Electric Generating Plant (Plant Bowen) in December 1979. The study was a joint endeavor of Battelle Pacific Northwest Laboratories (PNL), Pennsylvania State University (PSU), and Oak Ridge National Laboratory (ORNL) with the main objective of determining the effects of the plant's smokestack effluents on aerosol characteristics and precipitation chemistry. Other objectives included studies of cooling tower temperature and humidity (T/h) plumes and drift drop concentrations. Conducted over a period of three weeks, the study involved an instrumented aircraft, pilot balloons, a tethered balloon system, a dense network of wetfall chemistry collectors and numerous ground- and tower-based meteorological instruments. Rainfall samples collected during the precipitation event of December 13, 1979, revealed ...

1980-10-01

44

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified ...

1998-01-16

45

Analysis of in-pile heat transfer tests: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of analysis of selected data from the NRU test series dealing with heatup and reflood heat transfer during postulated PWR LOCA conditions. These tests used nuclear fuel rods and some considered clad ballooning and rupture. Also included was an electrically-heated rod ballooning test, REBEKA-6. The COBRA-TF computer program, renamed PYTHONS, was modified and used for the analytical tool. Modifications included provisions for fuel rod gas flow and pressure, creep deformation and rupture, channel blockage, and blockage heat transfer. Calculated clad temperatures for NRU unpressurized rods show quite good agreement with experimental data. The calculated amount and axial extent of clad ballooning for pressurized rods agrees reasonably well with post-test examinations of the NRU bundles. Time to failure was underpredicted in the MT-3 test as a result of the high strength of NRU clad material which ...

1986-11-01

46

Use of neural network techniques to identify cosmic ray electrons and positrons during the 1993 balloon flight of the NMSU/Wizard-TS93 instrument  

Energy Technology Data Exchange (ETDEWEB)

The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.

1995-09-01

47

Percutaneous mechanical declotting of thrombosed dialysis graft  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and fast, and is well ...

2000-10-01

48

Ideal MHD stability properties of pressure-driven modes in low shear tokamaks  

Energy Technology Data Exchange (ETDEWEB)

The role of shear in determining the ideal MHD stability properties of tokamaks is discussed. In particular, we assess the effects of low shear within the plasma upon pressure-driven modes. The standard ballooning theory is shown to break down, as the shear is reduced and the growth rate is shown to be an oscillatory function of n, the toroidal mode number, treated as a continuous parameter. The oscillations are shown to depend on both the pressure and safety-factor profiles. When the shear is sufficiently weak, the oscillations can result in bands of unstable n values which are present even when the standard ballooning theory predicts complete stability. These instabilities are named ''infernal modes.'' The occurrence of these instabilities at integer n is shown to be a sensitive function of q-axis, raising the possibility of a sharp onset as plasma parameters evolve. 20 refs., 31 figs.

1987-03-01

49

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like global shear regime that is inherent to such systems.

1996-05-01

50

Endofibrosis of Iliac Arteries in High-Performance Athletes: Diagnostic Approach and Minimally Invasive Endovascular Treatment  

International Nuclear Information System (INIS)

The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected, resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.

2006-10-01

51

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion ...

52

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

53

Hyperthermia in the Treatment of Cholangiocarcinoma: Development and Testing of an Endobiliary Microwave Device  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction of coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the ...

2003-08-01

54

Crumbling case for nuclear power  

Energy Technology Data Exchange (ETDEWEB)

In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.

1983-01-01

55

Global mode analysis of ideal MHD modes in a heliotron/torsatron system. 1. Mercier-unstable equilibria  

Energy Technology Data Exchange (ETDEWEB)

By means of a global mode analysis of ideal MHD modes for Mercier-unstable equilibria in a planar axis L=2/M=10 heliotron/torsatron system with an inherently large Shafranov shift, the conjecture from local mode analysis for Mercier-unstable equilibria given in [N. Nakajima, Phys. Plasmas 3, 4556 (1996)] has been confirmed and the properties of pressure-driven modes, namely, ballooning modes and interchange modes, inherent to such three-dimensional systems have been clarified. The change of the local magnetic shear due to the Shafranov shift, which is related to toroidicity, reduces the field line bending stabilizing effects on ballooning modes. According to the degree of the reduction of the local magnetic shear by the Shafranov shift, the Mercier-unstable equilibria are categorized into toroidicity-dominant (strong reduction) and helicity-dominant (weak reduction) Mercier-unstable equilibria. Since the local magnetic curvature due to helicity ...

1998-12-01

56

CT of blunt chest trauma in children  

Energy Technology Data Exchange (ETDEWEB)

While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. Children demonstrating findings incidental to the actual injury yet important to the ...

1993-03-01

57

Differential flux measurement of atmospheric pion, muon, electron and positron energy spectra at balloon altitudes  

Energy Technology Data Exchange (ETDEWEB)

The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray experiments gathering data below a few g/cm{sup 2} ...

1995-09-01

58

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

59

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: ...

2010-01-01

60

Anesthesia Technique and Outcomes of Endovascular Aneurysm Repair  

British Library Electronic Table of Contents (United Kingdom)

Anesthetic techniques vary widely in the endovascular repair of abdominal aortic aneurysms (EVAR). Previous studies have demonstrated the feasibility of using local anesthesia. However, the ideal anesthetic technique has not been determined. This study examines whether anesthesic technique influences the outcomes of EVAR. Data regarding demographics, risk factors, procedural characteristics, recovery characteristics, treatment complications, acute ( 0.05, ANOVA). From these results we concluded that EVAR with local anesthesia is a safe and efficacious method that may reduce recovery times and postoperative medical morbidity compared to use of genera1 or spinal/epidural anesthesia.

2005-01-01

 
 
 
 
61

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

62

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

63

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight  

CERN Document Server

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.

2008-01-01

64

Geometry changes transient transport in plasmas  

Energy Technology Data Exchange (ETDEWEB)

Role of ballooning effect in toroidal plasmas on the transient transport problems is investigated. Due to the mode localization along the magnetic field line, a meso scale appears in a radial correlation length of fluctuating fields. This scale length introduces the interference of the gradient and flux in different radial locations. For the fluctuation which gives the gyro-Bohm-like diffusion in a stationary state, this long radial correlation of the fluctuating field causes a fast propagation of response against a rapid transient perturbation. Upper bound of transient thermal diffusivity is derived. (author)

2001-06-01

65

Core localized toroidal Alfven eigenmodes destabilized by energetic ions in the CHS heliotron/torsatron  

Energy Technology Data Exchange (ETDEWEB)

Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)

1999-09-01

66

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...

2008-09-15

67

Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent ...

2007-08-15

68

Vascular ATP-sensitive potassium channels are over-expressed and partially regulated by nitric oxide in experimental septic shock  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the activation and expression of vascular (aorta and small mesenteric arteries) potassium channels during septic shock with or without modulation of the NO pathway. Methods Septic shock was induced in rats by peritonitis. Selective inhibitors of vascular KATP (PNU-37883A) or BKCa [iberiotoxin (IbTX)] channels were used to demonstrate their involvement in vascular hyporeactivity. Vascular response to phenylephrine was measured on aorta and small mesenteric arteries mounted on a wire myograph. Vascular expression of potassium channels was studied by PCR and Western blot, in the presence or absence of 1400W, an inducible NO synthase (iNOS) inhibitor. Aortic activation of the transcriptional factor nuclear factor-kappaB (NF-?B) was assessed by electrophoretic mobility shift as...

2011-01-01

69

The value of cardiac catheterization and cineangiography in infantile lobar emphysema  

International Nuclear Information System (INIS)

Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).

70

The chance finding of an aneurysm of the right sinus of Valsalva in an 11-year-old child with a ventricular septal defect and a pericardial effusion  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...

2011-01-01

71

RIFLE Criteria for Cardiac Surgery-Associated Acute Kidney Injury: Risk Factors and Outcomes  

British Library Electronic Table of Contents (United Kingdom)

The aims of this study were to identify risk factors and evaluate the association with clinical outcomes of postoperative cardiac surgery-associated acute kidney injury (CSA-AKI). Data from 2488 consecutive adult patients were analyzed. Patients were classified as having CSA-AKI based on the risk, injury, failure, loss of kidney function, and end-stage kidney disease (RIFLE) criteria using peak postoperative creatinine in the postoperative intensive care unit (ICU). Multiple stepwise logistic regression analysis was used to identify independent risk factors for CSA-AKI. CSA-AKI occurred in 584 patients (23.5%). CSA-AKI patients had significantly longer aortic cross-clamp and cardiopulmonary bypass times. Furthermore, CSA-AKI patients had higher hospital mortality (5.5% vs 1.5%, PCopyright2...

2010-01-01

72

Quantification of the thrombogenicity of Dacron aortic prostheses  

International Nuclear Information System (INIS)

Eight patients with double-velour Dacron aorto-femoral grafts implanted for 2-60 months were studied. Indium-111-labelled platelets were found to have a shortened mean platelet lifespan (MPLS) of 138 +- 32 hours compared with the normal platelet lifespan of 224 +- 23 hours. Labelled platelets accumulated on all grafts, irrespective of graft age, to a maximum of 1,80 +- 0,83% of whole body radioactivity; thereafter graft radio-activity decreased. This suggests that platelets on the graft are in dynamic equilibrium with those in the circulation. Platelets may be lost from the graft by embolization or radioactivity may be released because of platelet lysis. Although MPLS may depend on the age and surface area of the graft, concomitant arterial disease probably also contributes to the shortened MPLS.

73

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 ...

2000-09-01

74

Perioperative Care of a Child with Transposition of the Great Arteries  

British Library Electronic Table of Contents (United Kingdom)

Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...

2011-01-01

75

Experimental measurement of low-energy antiprotons in the cosmic radiation  

Energy Technology Data Exchange (ETDEWEB)

Researchers report results from the Low Energy Antiproton Experiment (LEAP), a balloon-borne instrument which was flown in August, 1987. They found a value of 4.2 by 10-6 for the antiproton to proton ratio in the energy range from 120 MeV to 600 MeV at the top of the atmosphere. In particular, this experiment places an upper limit on the flux almost an order of magnitude below the reported flux of Buffington et al. This upper limit allows us to place significant constraints on both the primordial black hole and weakly interacting Majorana Fermion hypothesis, as well as on the low energy processes in more conventional models of galactic cosmic ray antiproton production.

1990-01-01

76

Atmospheric proton and deuterium energy spectra determination with the MASS2 experiment  

Energy Technology Data Exchange (ETDEWEB)

The energy spectra of atmospheric-secondary protons and deuterium nuclei have been measured during the September 23, 1991, balloon flight of the NMSU/Wizard - MASS2 instrument. The apparatus was launched from Fort Sumner, New Mexico. The geomagnetic cutoff at the launch site is about 4.5 GV/c. The instrument was flown for 9.8 hours at an altitude of over 100,000 feet. Particles detected below the geomagnetic cutoff have been produced mainly by the interactions of the primary cosmic rays with the atmosphere. The measurement of cosmic ray energy spectra below the geomagnetic cutoff provide direct insights into the particle production mechanism and allows comparison to atmospheric cascade calculations.

1995-09-01

77

Aerial dispersal plasticity under different wind velocities in a salt marsh wolf spider  

British Library Electronic Table of Contents (United Kingdom)

Dispersal can be regarded as a process operating both between and within patches of suitable habitat. For uncontrolled dispersal processes, the risk of crossing the borders of the habitat patch and arriving in the unsuitable landscape matrix will increase with decreasing patch area, in particular when the distance between isolated habitat patches is larger than the species' average dispersal capacity. Ballooning dispersal in spiders can be considered as a passive dispersal process, in which dispersed distances depend on the prevalent wind velocity. We executed a reaction norm analysis to analyze how dispersal propensity of the salt marsh wolf spider Pardosa purbeckensis depended on population characteristics (patch size) and the environment (wind velocity). Dispersal propensity was affecte...

2007-01-01

78

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...

2003-07-01

79

Altered glycosaminoglycan metabolism in injured arterial wall  

Energy Technology Data Exchange (ETDEWEB)

Glycosaminoglycans (GAG) are believed to be important in the pathogenesis of atherosclerosis. We have previously demonstrated that areas of injured aorta that have been re-endothelialized accumulate increased amounts of lipid and GAG when compared to areas remaining de-endothelialized. We have now examined the net incorporation of labeled precursors into the individual GAG present in both re-endothelialized and de-endothelialized areas of rabbit aorta. Aortic tissue was examined at 2-3 and 10-14 weeks after a denuding injury by incubating tissue minces with (/sup 3/H)glucosamine and sodium (/sup 35/S)sulfate for 24 hr. Following incubation, the aortic GAG were isolated and assayed for uronic acid concentration and radioactivity. Results indicate that the total GAG concentration was significantly greater in the re-endothelialized as compared to de-endothelialized areas. The concentration in uninjured aorta was 9.01. The difference between the ...

1985-06-01

80

Damping of toroidal ion temperature gradient modes  

Energy Technology Data Exchange (ETDEWEB)

The temporal evolution of linear toroidal ion temperature gradient (ITG) modes is studied based on a kinetic integral equation including an initial condition. It is shown how to evaluate the analytic continuation of the integral kernel as a function of a complex-valued frequency, which is useful for analytical and numerical calculations of the asymptotic damping behavior of the ITG mode. In the presence of the toroidal {nabla}B-curvature drift, the temporal dependence of the density and potential perturbations consists of normal modes and a continuum mode, which correspond to contributions from poles and from an integral along a branch cut, respectively, of the Laplace-transformed potential function of the complex-valued frequency. The normal modes have exponential time dependence with frequencies and growth rates determined by the dispersion relation while the continuum mode, which has a ballooning structure, shows a power law decay {proportional_to} t{sup -2} in ...

1999-04-01

 
 
 
 
81

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven ...

82

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?  

International Nuclear Information System (INIS)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-01-01

83

Salicylate Treatment Improves Age-Associated Vascular Endothelial Dysfunction: Potential Role of Nuclear Factor kB and Forkhead Box O Phosphorylation  

British Library Electronic Table of Contents (United Kingdom)

We hypothesized that I kappa B kinase (IKK)-mediated nuclear factor kappa B and forkhead BoxO3a phosphorylation will be associated with age-related endothelial dysfunction. Endothelium-dependent dilation and aortic protein expression/phosphorylation were determined in young and old male B6D2F1 mice and old mice treated with the IKK inhibitor, salicylate. IKK activation was greater in old mice and was associated with greater nitrotyrosine and cytokines. Endothelium-dependent dilation, nitric oxide (NO), and endothelial NO synthase phosphorylation were lower in old mice. Endothelium-dependent dilation and NO bioavailability were restored by a superoxide dismutase mimetic. Nuclear factor kappa B and forkhead BoxO3a phosphorylation were greater in old and were associated with increased express...

2011-01-01

84

Micropatterned polysaccharide surfaces via laser ablation for cell guidance  

Energy Technology Data Exchange (ETDEWEB)

Micropatterned materials were obtained by a controlled laser ablation of a photoimmobilised homogeneous layer of hyaluronic acid (Hyal) and its sulphated derivative (HyalS). The photoimmobilisation was performed by coating the polysaccharide, adequately functionalised with a photoreactive group, on aminosilanised glass substrate and immobilising it on the surface under UV light. Hyal or HyalS photoimmobilised samples were then subjected to laser ablation with wavelengths in the UV regions in order to drill the pattern. Four different patterns with stripes of 100, 50, 25 and 10 {mu}m were generated. A chemical characterisation by attenuated total reflection/Fourier transform infrared (ATR/FT-IR) and time of flight-secondary ions mass spectrometry (TOF-SIMS) confirmed the success of the laser ablation procedure and the presence of alternating stripes of polysaccharide and native glass. The exact dimensions of the stripes were determined by atomic force microscopy. The analysis of cell ...

2003-03-03

85

Effects of chronic treatment with honokiol in spontaneously hypertensive rats.  

Science.gov (United States)

The present study was performed to evaluate the antihypertensive effects of honokiol in vivo in spontaneously hypertensive rats (SHR). The effects of honokiol were investigated by determination of the blood pressure, vascular reactivity, oxidative parameters, and histologic change in the aorta. Long-term administration of honokiol (400 mg/kg/d) to SHR decreased systolic blood pressure significantly. Honokiol (200, 400 mg/kg/d) enhanced the aortic relaxation in response to acetylcholine after 49-d treatment, but had no significant effects on the relaxation to sodium nitroprusside. The oral administration of honokiol significantly increased the plasma level of NO(2(-))/NO(3(-)), but decreased the level of malondialdehyde in liver of SHR compared with the control vehicle. In addition, SHR administered honokiol showed significant reductions in the elastin bands and media thickness in the aorta. These results suggest that chronic treatment with honokiol exerts an ...

2010-01-01

86

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...

2009-04-15

87

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT ...

1997-01-01

88

Cell behaviour on chemically microstructured surfaces  

Energy Technology Data Exchange (ETDEWEB)

Micropatterned surfaces with different chemical topographies were synthesised in order to investigate the influence of surface chemistry and topography on cell behaviour. The microstructured materials were synthesised by photoimmobilising natural Hyaluronan (Hyal) and its sulphated derivative (HyalS), both adequately functionalised with a photorective moiety, on glass substrates. Four different grating patterns (10, 25, 50 and 100 {mu}m) were used to pattern the hyaluronan. The micropatterned samples were analysed by Secondary Ions Mass Spectrometry, Scanning Electron Microscopy (SEM) and Atomic Force Microscopy to investigate the chemistry and the topography of the surfaces. The spectroscopic and microscopic analysis of the microstructured surfaces revealed that the photoimmobilisation process was successful, demonstrating that the photomask patterns were well reproduced on the sample surface. The influence of chemical topographies on the cell behaviour was then analysed. Human and ...

2003-03-03

89

Transplantation of neurospheres derived from bone marrow stromal cells promotes neurological recovery in rats with spinal cord injury  

British Library Electronic Table of Contents (United Kingdom)

Previous studies have revealed that cell therapy using bone marrow stromal cells (BMSCs) could promote motor functional recovery in animals with spinal cord injury (SCI). We describe here the development of cell biology technique and the experimental study of regeneration in SCI. The aim of this study was to investigate the potential for neurological recovery by transplantation neurospheres (NS) derived from BMSCs into thoracic SCI. Adult Fisher rats were used: 45 were subjected to complete thoracic SCI performed by the balloon compression method. BMSCs were cultured in vitro to obtain NS. Seven days after thoracic SCI, groups of 15 rats each received transplants of BMSCs-NS (group A), BMSCs (group B), or injection of medium only (group C) into the SCI lesion. Rats from each group were eva...

2011-01-01

90

Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. II. Straylight evaluation  

CERN Document Server

Satellite CMB anisotropy missions and new generation of balloon-borne and ground experiments, make use of complex multi-frequency instruments at the focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground contamination is minimum, it is extremely important to reach the best trade-off between the improvement of the angular resolution and the minimization of the straylight contamination mainly due to the Galactic emission. We focus here, as a working case, on the 30 and 100 GHz channels of the Planck Low Frequency Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic foreground components for a reference set of optical configurations. We show that it is possible to improve the angular resolution of 5-7% by keeping the overall GSC below the level of few microKelvin. A comparison between the level of straylight introduced by the different Galactic components for different beam regions is presented. Simple approximate ...

2003-01-01

91

The cosmic-ray antiproton spectrum between 0. 1 and 1. 5 GeV kinetic energy  

Energy Technology Data Exchange (ETDEWEB)

In the summer of 1980, a balloon-borne cosmic ray experiment reported the detection of 14 low energy antiprotons during an 18 hour flight. This measurement represented an antiproton intensity two orders of magnitude greater than that predicted by conventional theories. This surprising result triggered a flurry of papers theorizing the origin of these particles, including the prediction of domains of primary antimatter, and evidence for supersymmetric particle annihilation. Not until the summer of 1987 was a follow up experiment (PBAR) performed. The PBAR detector has both better resolution and a larger dynamic range in energy than the previous detector. It measured the energy spectrum of antiprotons in the 0.1-1.5 GeV kinetic energy range. The present work describes the instrument, the experiment, and the results. Our analysis of the PBAR data reveals no antiprotons in the energy range of 0.13-0.64 GeV and only one antiproton candidate for energies between 0.64 and ...

1988-01-01

92

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the optical fibers into ...

2002-01-01

93

OZONE PRODUCTION IN THE PHILADELPHIA URBAN AREA DURING NE-OPS 99  

International Nuclear Information System (INIS)

As part of the 1999 NARSTO Northeast Oxidant and Particulate Study (NE-OPS) field campaign, the DOE G-1 aircraft sampled trace gases and aerosols in and around the Philadelphia metropolitan area. Twenty research flights were conducted between July 25 and August 11. The overall goals of these flights were to obtain a mechanistic understanding of O(sub 3) production; to characterize the spatial and temporal behavior of photo-oxidants and aerosols; and to study the evolution of aerosol size distributions, including the process of new particle formation. Within the NE-OPS program, other groups provided additional trace gas, aerosol, and meteorological observations using aircraft, balloon, remote sensing, and surface based instruments (Phillbrick et al., 2000). In this article we provide an overview of the G-1 observations related to O(sub 3) production, focusing on the vertical distribution of pollutants. Ozone production rates are calculated using a box model that is ...

94

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...

2005-01-01

95

The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent  

Energy Technology Data Exchange (ETDEWEB)

To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ...

2008-05-15

96

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?; La semiluna e l`alone periluminale: Due segni con Tomografia Computerizzata di aneurisma aortico a rischio di rottura?  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-04-01

97

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

98

Intestinal circulation during inhalation anesthesia  

Energy Technology Data Exchange (ETDEWEB)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of /sub 86/Rb and 9-microns spheres labeled with /sup 141/Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. Halothane, enflurane, ...

1985-04-01

99

Intestinal circulation during inhalation anesthesia  

International Nuclear Information System (INIS)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of _8_6Rb and 9-microns spheres labeled with "1"4"1Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. Halothane, enflurane, and ...

100

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January through December 1984 were analized. 90 % of ...

1984-12-01

 
 
 
 
101

Corrected transposition of the great arteries  

International Nuclear Information System (INIS)

The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has levocardia with situs inversus. 2. Segmental sets are (S, L, L) in 15 ...

1981-12-01

102

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...

1991-01-01

103

Washboard modes as ELM-related events in JET  

Energy Technology Data Exchange (ETDEWEB)

Washboard (WB) modes (Smeulders P et al 1999 Plasma Phys. Control. Fusion 41 1303) are a very common edge instability regularly observed in the H-mode regime in JET. They are detected as (normally several) bands of continuously fluctuating magnetic activity rotating in the direction of the electron diamagnetic drift with typical frequencies in the range of 10-90 kHz. The time evolution of the WB mode frequency is found to follow qualitatively the evolution of the electron temperature measured near the pedestal top, probably due to the strong diamagnetic drift associated with the large pedestal gradients. Evidence for their involvement in the pedestal and ELM dynamics will be presented. Increasing WB mode amplitude is correlated with an increase in the time between consecutive type-I ELMs. In situations in which a sudden increase (decrease) of WB mode activity is observed, the build-up of the pedestal temperature (and, linked to this, also of the pedestal pressure) of the electrons is ...

2004-01-01

104

Time Management in Acute Vertebrobasilar Occlusion  

International Nuclear Information System (INIS)

Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in ...

2009-03-01

105

Measurement of the cosmic-ray antiproton flux and a search for an antihelium  

Energy Technology Data Exchange (ETDEWEB)

A balloon-borne instrument has measured the cosmic-ray antiproton flux between 130 and 320 MeV and searched for antihelium between 130 and 370 MeV per nuclear. These particles were selected from the background of normal-matter cosmic rays by combining a selective trigger with a detailed spark chamber visualization of each recorded event. Antiprotons are identified by their characteristic annihilatin radiation. Residue from background processes meeting the selection criteria is small. The observed 14 antiprotons yield a measured differential flux of 1.7 +- 0.5 x 10/sup -4/ antiprotons m/sup -2/ sr/sup -1/ s/sup -1/ MeV/sup -1/ at the top of the atmosphere. The corresponding antiproton/proton ratio is 2.2 +- 0.6 x 10/sup -4/,, only slightly smaller than the ratio observed by other experiments at higher energies. Thus the antiprotons have a spectral shape similar to the protons, at least down to about 100 MeV. The expected flux of these particles can be calculated ...

1981-09-15

106

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...

2002-05-01

107

Transpositions and malpositions of the great arteries  

International Nuclear Information System (INIS)

The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 17 months, with specific references to the ...

1980-12-01

108

Computed tomography of the mediastinal lesion  

Energy Technology Data Exchange (ETDEWEB)

Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower densities were seen in ...

1984-09-15

109

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

110

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

111

Diagnosis and therapy of Budd-Chiari syndrome; Diagnostik und Therapie des Budd-Chiari-Syndroms  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no complications were ...

1998-09-01

112

Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART); Perkutane Therapie inoperabler maligner Stenosen und Verschluesse der Gallenwege mit einem neu entwickelten selbstexpandierbaren Nitinolstent (SMART)  

Energy Technology Data Exchange (ETDEWEB)

Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% ...

2002-10-01

113

A new concept for covered stent protected carotid angioplasty: an ex vivo study  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the efficacy of a covered stent prototype designed for protected carotid angioplasty to reduce cerebral embolization. Material and Method: The covered stent tested is made of nitinol, coated with a polyurethane membrane (MembraX{sup TM}; porous size 80 {mu}m). In a bench-top model (flow-rate 650 ml/min, pulsatile flow [dicrote] 123 Pulses/min, pressure 100/60 mm Hg [mean pressure 80 mmHg]) with inserted human carotid (n=6) stent implantation was performed (8/32 mm). Passed particles (mg) were determined in the effluent of a 100 {mu}m filter prior to intervention, after stent deployment and after final dilation (5 mm). Results: When stenting carotid arteries obtained from human cadavers, the highest rate of particle embolization was measured while crossing the lesion with the delivery device (6,8 mg; for all p<0,05), embolization after additional balloon angioplasty and particle rates measured in the effluent filter prior covered stent ...

2003-12-01

114

The angiogram sign in pulmonary atelectasis studied with helical Computed Tomography. Incidence and value; Il segno dell'angiogramma nelle atelettasie polmonari studiate con Tomografia Computerizzata spirale. Incidenza e validita' semeiologica  

Energy Technology Data Exchange (ETDEWEB)

In this issue it has been investigated the yield of Helical CT in the study of lung vessels, the incidence of the angiogram sign and its actual value. July 1997 to December 1998, were studied 30 cases of pulmonary collapse of different origin. It was found 15 cases of passive collapse (10 from pleural effusion, 2 from diaphragmatic compression, 2 from traumatic pneumothorax, and 1 from isthmic aortic aneurysm), 12 cases of obstructive collapse (9 from bronchogenic carcinoma, 1 from mucoid obstruction, 1 from ilar lymphadenopathy, and 1 from mediastinal cancer), 2 cases of adhesive collapse and 1 case of round atelectasis. All the examinations were performed with the Helical technique during nonionic iodinated contrast agent injection (bolus, 300-350 mg/mL); it was used an automatic injector set at 2-3 mL/s. It was studied the images for the angiogram sign, that is hyperdense bands, usually longer than 2 cm, through the collapsed lung, which correspond to normal ...

1999-12-01

115

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and ...

2002-10-01