Hydrology and hydrogeochemical are auxiliary techniques to valid conceptual hydrogeology an recharge models. Stable isotopes from water trace sources and path flow and Tritium indicates age. This paper is about the use of D 18, D2H y 3H to study the aquifer system on Bajo Cauca antioqueno.
Sirio is a computerized application to manage the hydroelectric system in a short time. This management is implemented as a real time tool in the Control Department. SIRIO has many modules, independent and integrated to operate and perform the data acquisition, optimization, planning simulation and planning optimization. This article presents the SIRIO System and its applications to the Iberdrola system in Tajo river.
Most waste water treatment plants have processes to remove nutrients in order to avoid eutrophication in water receiving bodies. Regarding phosphorus removal. the most common option is chemical precipitation with ferric or aluminical precipitation with ferric or aluminium salts. We show here the successful experience carried out by the WWTP of Blanes and the company Safloc. A method ato remove phosphorus from waste water was developed by adding sodium aluminate. The use of this compound has turned out to be a sustainable way for this purpose in terms of costs, reliability and minimization of sludge production. (Author)
The objective of this project was to develop a explosion suppression system capable to confine and extinguish gas explosions of the type produced in sub level caving faces when blasting to the coal pillar. Existing systems, such as triggered barriers, were considered not to be valid because of size, weight, cost, and other operational constraints. The research activities have been focused in the development of a mixed water/air spray system that should be manually activated some second before blasting. Two prototypes have been developed and tested, the first one using nozzle operating at the standard ranges of pressure that are normally available in underground coal mines, and a second one based in high-pressure nozzles. In this case, bottles containing a pressurized air/water mixtures are required. The works carried out included theoretical studies, hydraulic nozzles characterization, and modelling of the explosion phenomena using the AutoReaGas code. Besides, extensive testing of the ...
Some of well known F{sub 2} layer anomalies might have their origin in lower atmosphere and some have extra terrestrial sources. It has been suggested that the phenomena occurring below the ionosphere such as thunderstorms, lightning/sprites, volcanic eruptions and earthquakes and above the phenomena like corona mass ejection, solar flares and extra terrestrial events may produce F{sub 2} layer signatures. In the present paper we have tried to summarize the effect of some phenomena occurring below the ionosphere like thunderstorms, lightning/sprites and seismic activity and the phenomena such as solar flares which occur above the ionosphere, on the ionospheric electron and ion temperatures. The paper also discusses possibilities. The ionospheric electron and ion temperatures were measured by the RrPAa payload aboard the Iindian SRrOSS-C2 satellite. The normal day's ion and electron temperatures have been compared to the temperatures recorded during the disturbed day. The ...
In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer estandares ...
Neutralizing an acidic fluid consists of adding a sodium hydroxide solution to neutralize the H group of acids, therefore increasing the pH. The injection of sodium hydroxide has to be continuous and at a proper depth inside the well to protect against the corrosion of casing and surface equipment. Neutralization is a common practice used in geothermal fields, such as at The Geysers in the US and Miravalles in Costa Rica-places where aggressive fluids cause problems for extracting and using geothermal fluids commercially. A zone surrounding wells H-4, H-16 and H-29 in the northern section of the Los Humeros, Pue., geothermal field, known as the Colapso Central, has shown evidence of aggressively acidic fluids. Several wells drilled in the area had to be repaired, thus plugging and isolating the deepest production zones. Well H-43 was drilled two years ago in the northern zone of the field, and even though it is not located in the aggressive-fluid zone, the well presents mineralogical ...