WorldWideScience
 
 
1

NASA - Informe De la Misi?n STS-126  

Science.gov (United States)

17 Nov 2008 ... El Analizador de Carbono Org?nico Total ser? usado para probar muestras que vendr?n del nuevo sistema de Recobre de Agua. ...

2

Water chemistry in the water-vapor circuit at Angra II: evolution of the operational concepts and canceling of the condensed polishing system; Quimica da agua do circuito agua-vapor de Angra II: evolucao do conceito operacional e o cancelamento do sistema de polimento do condensado  

Energy Technology Data Exchange (ETDEWEB)

The chemical operational concept originally established for the water-steam circuit of Angra II nuclear power plant has undergone several modifications throughout the development of the project. This work discusses the two main modifications giving special attention to the costs involved and analyses the main points and the consequences of such modifications 1 ref., 4 figs., 2 tabs.

1995-12-31

3

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

4

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

5

New technology for the emulsification of petroleum residuals in water; Nueva tecnologia para la emulsificacion de residuales del petroleo en agua  

Energy Technology Data Exchange (ETDEWEB)

It turns out of interest to Comision Federal de Electricidad and Petroleos Mexicanos to reduce costs of fuel oil, reducing the viscosity of the residues petroleum of high vacuum distillation emulsifying these with water. The parameters that define the characteristics of the emulsions are mainly the relation of their components, viscosity, size and drop distribution and its stability. The experimental work began producing emulsions in form of lots, using samples of approximately 500 milliliters of vacuum residue. In this first stage, at different concentrations, were examined eight different surfactants, as well as combinations among them, also seven different stabilizers were used. With these tests it has been managed to identify the concentrations, as well as the most adequate relations of surfactants and stabilizers for the production of emulsions of vacuum residues in water. The size and drop distribution has been determined by means of an optical LEICA microscope, model DMLS, that ...

2001-07-01

6

The use of WASP model for planning the Portuguese electrical generating system: overcoming some difficulties  

International Nuclear Information System (INIS)

The paper discusses the methodology used at Electricidade de Portugal (EDP) in planning its electric power system. In particular, it considers a description of the methodology used by EDP for a more accurate definition of the input data required to characterize hydroelectric plants and the evaluation of their impact on an optimal long-term expansion plan. In addition, the paper describes an analysis of the results of studies, both with WASP-II and WASP-III, with and without pumped storage plants, respectively. Finally, the paper details the use of VALOR AGUA, in conjunction with WASP, for a better simulation of the hydroelectric system and which also permits to solve other problems closely connected such as the calculation of marginal production costs. (author).

1986-02-01

7

Potential migration of organic pollutants in pipes of polyethylene. Study in pipelines of distribution net of drinkable water; Migracion potential de contaminantes organicos en tubos de polietileno. Estudio en tuberias de red de distribuciond e agua potable  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene pipes and connections are being widely used in treated water distribution services. Migration of low molecular weight compounds from the polyethylene into the water can change its final quality. This paper is about the concentrations and identification of the migration compounds found in treated water after staying in contact with low and high-density polyethylene. Identification and quantification were carried out using CLSA (Closed Loop Stripping Analysis) extraction technique and gas chromatography coupled to mass spectrometry (HRGC/HRMS). (Author) 12 refs.

2002-07-01

8

Treatment of produced water using hydrocyclones; Tratamento de agua produzida usando hidrociclone  

Energy Technology Data Exchange (ETDEWEB)

Beyond a great number of applications in mineral process, the hydrocyclone separation has been used recently in an increasing number of fields, such as: environmental engineering, petrochemical engineering, food engineering, electrochemical engineering, pulp bioengineering, processes and paper industries, among others. Nowadays, the produced water is treated and then reinjected in the surface and also in return to the formation. In the offshore platforms, the produced water can be directly discarded in the ocean, since the dispersed phase concentration (oil) is according to Brazilian regulating agency limits. The basic principle used in hydrocyclone separation is the centrifugal sedimentation machine: the suspended particles are submitted to centrifugal acceleration, which separates them from the fluid. The basic geometry of a hydrocyclone consists of four parts: a cylindrical section for feeding, a conical section for swirling, an overflow and an under flow. The project depends on the ...

2008-07-01

9

Separation of the components of the binary mixture ethanol-water by steam flux in solid phase column; Separacao dos componentes da mistura binaria etanol-agua por passagem do vapor em coluna de fase solida  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the energy required to separate ethanol from an aqueous solution in a distillation column containing a solid phase. The solid phases evaluated consisted of either an amylatious (ground corn) or a cellulose (sugar cane bagasse) absorber whit particle sizes smaller than 4 mm. The water-retention capacity of each solid phase was measured by passing vapors or ethanol-water mixtures through the solid phase. When starting with initial concentrations bellow the azeotropic point, ethanol concentrations up to 99,5% (on corn) and 97,2% (on sugar cane) were achieved. The water content was evaluated potentiometrically (Karl`Fischer). Regarding the 2-4 mm ground corn solid phase column, the energy consumed was estimated to be reduced by 15,6% and 60% (by weight) ethanol-water mixture respectively. (author) 11 refs., 2 figs., 2 tabs

1987-12-31

10

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an integral planning of ...

2005-07-01

11

Produced water treatment using polymeric resins; Resinas polimericas para tratamento da agua produzida  

Energy Technology Data Exchange (ETDEWEB)

The treatment and disposal of oily waters from oil production and refining processes represent an important technological pass for attendance of the ambient legislation and to the politics of the Cia of search of the environmental excellence. The reuse or reinjection of the co-produced water has been considered an interesting strategical alternative, however, the water quality requirement for these processes demands a pretreatment step, considering the exit effluent from primary and secondary treatment processes currently used. This work presents resulted of the polymeric resin development for tertiary treatment of oily waters with low oil and grasses content and fine solids, including the dissolved fraction. These resins can adsorb, in reversible form, organic components. Its high adsorption capacity is determined by the polarity, superficial area, range of porosity and a wide distribution of particle size and pore. Another important characteristic is the possibility of its use in ...

2008-07-01

12

Eliminating incrusted solids in drinking water conduits in Cantillana, Seville, Spain; Eliminacion de los solidos incrustados en las conducciones de agua potable de Cantillana (Sevilla)  

Energy Technology Data Exchange (ETDEWEB)

The presence of iron and manganese in underground water due to rock leaching may cause problems in drinking water. the oxidation of these metals produces precipitates which alter water quality (by making it cloudy and bad testing) and may even block supply pipes. This article presents a way eliminating this problem which was tried out in the conduits of Cantillana, a municipality in the province of Seville, Spain. Cleaning the pipes with a mixture of H{sub 2}O{sub 2} + water changes the characteristics of the deposits from flocculant and absorbent to sandy following which they are washed away by the pressure of the water. Once the pipes have been cleaned, a minimal amount of maintenance will prevent the formation of new deposits. This article thus a relatively simple and economical solution for recovering water quality as an alternative to the complicated replacement of the whole network. (Author) 7 refs.

1998-12-01

13

Effects of morpho dynamics in shallow waters over pipeline facilities; Efeitos da morfodinamica em aguas rasas sobre instalacoes de dutos  

Energy Technology Data Exchange (ETDEWEB)

The success in developing of the oil industry operating in offshore-onshore terminals, connected by pipelines with the facilities of the coastal zone, can be attributed partially to the beach morpho dynamic monitoring. This study represents a solution to the concerns of the technical operations in coastal zones because it minimizes the impact of the petroleum production and it assures the environmental protection associated to the risks of the pipelines breaking. This impact type results mainly of the vertical and horizontal displacements of the beach, from the coastal dunes to the shore face. The mobility of the profile is associated to the magnitude of the sedimentary processes, which reproduce naturally or not, in scale of time that can vary among few days, years or decades. For the monitoring and interpretation of the beach profile mobility the following methods are recommended: calculation of the closure depth with base in the wave data; bathymetric survey with sled; calculation ...

2003-07-01

14

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed plants. In all cases, the total radioactivity level was lower than the maximum ...

2009-10-15

15

Development of a new tool for predicting water quality. Verification on a stretch of the river Ebro; Desarrollo de una nueva herramienta para la prediccion de la calidad del agua. Verificacion en un tramo del rio Ebro  

Energy Technology Data Exchange (ETDEWEB)

The Water Frame work Directive (December 2000) proposes integrated water management in regard to both quality and quality. A mathematical model has therefore been produced at the CEIT and EPTISA research centre, in collaboration with the Ebro Hydrographic. Confederation (CHE), to predict water quality and thus begin integrated management of it in the river basins. A description is given of the characteristics of the simulation tool. The hydraulic model is based on the numerical (weighted, four-point implicit) resolution of the complete Saint Venant equations. The quality model is based on the IWA River Water Quality Model Number 1 which has clear advantages (consistency, mass balance and easy integration with the biological models of the waste water treatment plants and the collector networks compared to traditional models. The experimental validation, which includes calibration in wintertime of the hydraulic and quality models most representative coefficients was assessed on the basis ...

2004-07-01

16

A method for the optimal design of networks of drinking water distribution; Un metodo para el diseno optimo de redes de distribucion de agua potable  

Energy Technology Data Exchange (ETDEWEB)

A method to select, among several commercial diameter options, the most economic combination of pipeline networks is presented. These networks comply with the discharge conditions in the pipes and pressure in the knots. It is applied a static method for the hydraulics analysis of the Engineering Institute of the Universidad Nacional Autonoma de Mexico (UNAM) and an optimization technique to reduce the number of calculations. [Spanish] Se presenta un metodo para seleccionar, de entre varias opciones de diametros comerciales, la combinacion que forma la red de tuberias mas economica que satisface las condiciones de gasto en los tubos y de presion en los nudos de la misma. Para el analisis hidraulico se emplea un metodo estatico del Instituto de Ingenieria de la Universidad Nacional Autonoma de Mexico (UNAM) y se aplica una tecnica de optimacion para reducir el numero de calculos y alcanzar la solucion.

1998-12-01

17

Self-construction of a solar water heater; Calentador solar de agua de auto-construccion  

Energy Technology Data Exchange (ETDEWEB)

In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer estandares internacionales a este respecto. El ...

2009-07-01

18

Energy analysis of a solar pre-water heating system; Analise energetica de um sistema de pre-aquecimento solar de agua  

Energy Technology Data Exchange (ETDEWEB)

Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough to recover such investments. The objective of this paper is to evaluate the total energy required in the construction of one of these systems and compare it to the ...

1996-12-31

19

The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales  

Energy Technology Data Exchange (ETDEWEB)

The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the electrical systems and the provision of steam ...

2001-07-01

20

Heat transfer equipment performance diagnosis of auxiliary systems in electric power stations; Diagnostico de comportamiento de equipo de transferencia de calor de sistemas auxiliares de centrales termoelectricas  

Energy Technology Data Exchange (ETDEWEB)

In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...

1990-12-31

 
 
 
 
21

Importance of the planning activities, cutting, handling and analysis of the nuclei of oil well drilling; Importancia de las actividades de planificacion, corte, manejo y analisis de los nucleos de perforacion de pozos petroleros  

Energy Technology Data Exchange (ETDEWEB)

In the geologic formation where the oil deposits are located, diverse types of rocks perform functions as structural elements, storage containers for hydrocarbon water and calorific energy, as well as impermeable barriers and transport means of the energy and the fluids. Among the most important properties that are used to describe these functions are the porosity, the permeability, the compressibility of the pores volume, the formation resistivity factor, the saturation exponent, the velocity of acoustic waves P and S, the relative permeability, the capillary pressures, the elastic constants and other mechanical properties, the thermal expansion, coefficient, the thermal conductivity, the thermal diffusivity and the specific heat. The execution of an ample variety of activities related to the stages of exploration, location, evaluation and development of the oil deposits, depends strongly on having a good knowledge of the magnitude and the spatial variability of these properties. The ...

2007-07-01

22

Geological evolution of the center-southern portion of the Guyana shield based on the geochemical, geochronological and isotopic studies of paleoproterozoic granitoids from southeastern Roraima, Brazil; Evolucao geologica da porcao centro-sul do escudo das Guianas com base no estudo geoquimico, geocronologico e isotopico dos granitoides paleoproterozoicos do sudeste de Roraima, Brasil  

Energy Technology Data Exchange (ETDEWEB)

This study focuses the granitoids of center-southern portion of Guyana Shield, southeastern Roraima, Brazil. The region is characterized by two tectonic-stratigraphic domains, named as Central Guyana (GCD) and Uatuma-Anaua (UAD) and located probably in the limits of geochronological provinces (e.g. Ventuari-Tapajos or Tapajos-Parima, Central Amazonian and Maroni-Itacaiunas or Transamazon). The aim this doctoral thesis is to provide new petrological and lithostratigraphic constraints on the granitoid rocks and contribute to a better understanding of the origin and geo dynamic evolution of Guyana Shield. The GCD is only locally studied near to the UAD boundary, and new geological data and two single zircon Pb-evaporation ages in mylonitic biotite granodiorite (1.89 Ga) and foliated hastingsite-biotite granite (1.72 Ga) are presented. These ages of the protholiths contrast with the lithostratigraphic picture in the other areas of Cd (1.96-1.93 Ga). Regional mapping, petrography, ...

2006-07-01