UK PubMed Central (United Kingdom)
Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available
2010-04-01
Intravascular ultrasound to guide the management of intracoronary thrombus: a Case Report
UK PubMed Central (United Kingdom)
Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available
UK PubMed Central (United Kingdom)
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
2010-04-01
British Library Electronic Table of Contents (United Kingdom)
Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
2012-01-01
UK PubMed Central (United Kingdom)
Disseminated intravascular coagulation (DIC) is a disorder characterized by both acute generalized, widespread activation of coagulation, which results in thrombotic complications due to the intravascular...Full Text Available
Artery phantoms for intravascular optical coherence tomography: healthy arteries
UK PubMed Central (United Kingdom)
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
A Method for Accurate in silico modeling of Ultrasound Transducer Arrays
UK PubMed Central (United Kingdom)
This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available
2009-05-01
International Nuclear Information System (INIS)
The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the ...
2006-02-01
British Library Electronic Table of Contents (United Kingdom)
This study examined whether elevated intravascular pressure stimulates asynchronous Ca2+ waves in cerebral arterial smooth muscle cells and if their generation contributes to myogenic tone development. The endothelium was removed from rat cerebral arteries, which were then mounted in an arteriograph, pressurized (20 100 mmHg) and examined under a variety of experimental conditions. Diameter and membrane potential (VM) were monitored using conventional techniques; Ca2+ wave generation and myosin light chain (MLC20)/MYPT1 (myosin phosphatase targeting subunit) phosphorylation were assessed by confocal microscopy and Western blot analysis, respectively. Elevating intravascular pressure increased the proportion of smooth muscle cells firing asynchronous Ca2+ waves as well as event frequency. C...
2010-01-01
UK PubMed Central (United Kingdom)
BackgroundThe pathogenicity of Plasmodium falciparum is in part due to the ability of the parasitized red blood cell (pRBC) to adhere to intra-vascular host cell...Full Text Available
UK PubMed Central (United Kingdom)
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
2009-07-01
UK PubMed Central (United Kingdom)
Intravascular coagulation, thrombosis, and fibrin deposition often produce tissue damage in allogeneic inflammatory reactions such as allograft rejection. The mechanisms which initiate blood clotting...Full Text Available
1978-09-01
Ultrasound diagnosis of cephalopagus conjoined twin pregnancy at 29 weeks
UK PubMed Central (United Kingdom)
The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face,...Full Text Available
UK PubMed Central (United Kingdom)
We investigate a method for gene delivery to vascular smooth muscle cells using ultrasound triggered delivery of plasmid DNA from electrostatically coupled cationic microbubbles. Microbubbles...Full Text Available
2010-09-01
Multi-focal optical-resolution photoacoustic microscopy in vivo
UK PubMed Central (United Kingdom)
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
2011-04-01
Mid-trimester diagnosis of bladder neck obstruction by ultrasound and paracentesis.
UK PubMed Central (United Kingdom)
A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available
1983-06-01
UK PubMed Central (United Kingdom)
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
2005-10-01
Multibeam backscatter imagery extracted from gridded bathymetry of Rose Island, American Samoa, South Pacific. These data provide coverage between 20 ... ...
Retrieval of intravascular foreign bodies with goose neck snare
Energy Technology Data Exchange (ETDEWEB)
Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is ...
2004-03-01
Analysis of superconducting oxide by 7 MeV alpha particle backscattering analysis
International Nuclear Information System (INIS)
High energy ion backscattering analysis in combination with recently-developed resonance scattering analysis is described, with a stress on precise and quantitative oxygen analysis and its successful application to the characterization and quality estimation of high T_c oxide superconductors. Particularly, the present status of high energy ion backscattering analysis, the review of analytical results for YBa_2Cu_3O_7 _- _x, the estimation of composition and crystalline quality of (La_1 _- _xSr_x)_2CuO_4 by 7 MeV alpha particle backscattering analysis are described.
1989-04-24
A refractory metal thin film evaporator for backscattering studies
International Nuclear Information System (INIS)
(1 Feb 1975). Netherlands Rollin, DF Robinson, JE McMaster Univ.,
1975-02-01
International Nuclear Information System (INIS)
Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.
2001-04-01
Transurethral Ultrasound Diffraction Tomography
... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...
2007-03-01
NASA - Get (In) on NASA Innovation!
Sep 19, 2011 ... (The whispering voice, on the other hand, was the latest in ultrasound directed audio technology from the firm Audio Spotlight.) The NASA ...
... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...
International Nuclear Information System (INIS)
Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.
2007-04-01
UK PubMed Central (United Kingdom)
Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available
2009-06-01
UK PubMed Central (United Kingdom)
BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available
Comparison of temperature and humidity profiles with elastic-backscatter lidar data
Energy Technology Data Exchange (ETDEWEB)
This contribution analyzes elastic-backscatter lidar data and temperature and humidity profiles from radiosondes acquired in Barcelona in July 1992. Elastic-backscatter lidar data reveal the distribution of aerosols within the volume of atmosphere scanned. By comparing this information with temperature and humidity profiles of the atmosphere at a similar time, we are able to asses de relationship among aerosol distribution and atmospheric stability or water content, respectively. Comparisons have shown how lidar`s revealed layers of aerosols correspond to atmospheric layers with different stability condition and water content.
1995-04-01
International Nuclear Information System (INIS)
... Smith, RC Westinghouse Research Labs., Pittsburgh v. 25(5) p. 292-295.
Biogeo-Optics: Backscattering Cross Sections for Suspended ...
... Mineral and Organic Matter in the Coastal and Near-Coastal Ocean. ... Personal Author(s) : Stavn, Robert H. ; Spiering, Bruce A. ; Gould, Richard W ...
2004-12-20
Simulation-based training improves applied clinical placement of ultrasound-guided PICCs
British Library Electronic Table of Contents (United Kingdom)
Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.
2011-01-01
First trimester measurements of nasal bone length using three-dimensional ultrasound
British Library Electronic Table of Contents (United Kingdom)
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
2009-01-01
International Nuclear Information System (INIS)
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
1999-01-01
International Nuclear Information System (INIS)
Radioactive "3"1Si(Tsub(1/2) = 2.62 h) and Rutherford backscattering were used to study Ni_2Si, Pd_2Si and Pt_2Si formation, silicon self-diffusion in silicides and silicon epitaxy in the Si(100)/Pd_2Si/Si (amorphous) system. (Auth.).
Ultrasound-Guided Three-In-One Nerve Block for Femur Fractures
UK PubMed Central (United Kingdom)
Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available
2010-09-01
Selective imaging of adherent targeted ultrasound contrast agents
UK PubMed Central (United Kingdom)
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
2007-04-21
PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION
UK PubMed Central (United Kingdom)
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available
2008-08-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available
Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.
UK PubMed Central (United Kingdom)
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
1997-03-01
Kaposi's sarcoma involving the thyroid in a patient with AIDS
International Nuclear Information System (INIS)
A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.
Endovascular surgery for peripheral arterial occlusive disease. A critical review.
UK PubMed Central (United Kingdom)
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
1992-07-01
Efficacy of ultrasound-guided obturator nerve block in transurethral surgery
UK PubMed Central (United Kingdom)
Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
BackgroundLifestyle, genetics and environmental factors are established determinants of bone density. We aimed to describe the bone characteristics of competitive top-ranked Nigerian...Full Text Available
UK PubMed Central (United Kingdom)
An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
1985-01-15
Interobserver agreement in ultrasonography of the finger and toe joints in rheumatoid arthritis.
DEFF Research Database (Denmark)
OBJECTIVE: To evaluate the interobserver agreement of ultrasonographic assessment of finger and toe joints in patients with rheumatoid arthritis (RA) by 2 investigators with different medical backgrounds. METHODS: Ultrasonography and clinical examination were performed on 150 small joints of 30 patients with active RA. A General Electric LOGIQ 500 ultrasound unit with a 7-13-MHz linear array transducer was used. In each patient, 5 preselected small joints (second and third metacarpophalangeal, second proximal interphalangeal, first and second metatarsophalangeal) were examined independently on the same day by 2 ultrasound investigators (an experienced musculoskeletal radiologist and a rheumatologist with limited ultrasound training). Joint effusion, synovial thickening, bone erosions, and power Doppler signal were evaluated in accordance with an introduced 4-grade semiquantitative scoring system, on which the investigators ...
2003-01-01
Production and stability of implanted Pd-Si hydride
Energy Technology Data Exchange (ETDEWEB)
Combining in situ Rutherford backscattering and electrical transport measurements on low-temperature hydrogen-implanted amorphous Pd/sub 80/Si/sub 20/ films, we have studied the correlation between the hydrogen content and the resistivity.
1983-05-01
Dosimetric characteristics of backscattered electrons in lead
Energy Technology Data Exchange (ETDEWEB)
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy incident on the scatterer between 0.5 and ...
2000-07-01
Detection of Second-Layer Corrosion in Aging Aircraft Fuselage
International Nuclear Information System (INIS)
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS ...
2006-12-01
Detection of Second-Layer Corrosion in Aging Aircraft
International Nuclear Information System (INIS)
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
The grain boundary crystallographic misorientations of magnetic-pulse-welded (MPW) aluminum alloy (AA) 6061-T6 in linear and tubular configurations were examined using the electron backscattered diffraction (EBSD) technique. A refined structure of heavily deformed grains with higher grain boundary angles was observed in linear welds. Significant spalling was observed away from the joints, in the interior of tubular welds. The results show the complex interaction of shock waves with the materials during this impact welding process.
2008-08-01
Directional wind-measurement derived from elastic backscatter lidar data in real-time
Energy Technology Data Exchange (ETDEWEB)
The development of a capability to infer wind velocities simultaneously at a number of ranges along one direction in real time is described. The elastic backscatter lidar data used was obtained using the XM94 lidar, developed by Los Alamos National Laboratory for the US Army Chemical and Biological Detection Command. In some respects this problem is simpler than measuring wind velocities on meso-meteorological scales. Other requirements, particularly high temporal fidelity, have driven the development of faster software algorithms and suggested opportunities for the evolution of the hardware.
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
1993-09-01
In vivo chicken model for peripheral intravascular human fibrin clot detection
Energy Technology Data Exchange (ETDEWEB)
A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.
1988-08-01
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic parameters are tuned as well ...
1995-08-01
The influence of ultrasound on the fluoroquinolones antibacterial activity
British Library Electronic Table of Contents (United Kingdom)
In this work, the antibacterial effect of fluoroquinolones (FQs) upon Escherichia coli (E.coli) was measured with and without application of 40kHz ultrasound (US) stimulation. The research results demonstrated that simultaneous application of 40kHz US apparently enhanced the antibacterial effectiveness of FQs. That is, the synergistic effect was observed and the bacterial viability was reduced when FQs and US were combined. In addition, various influencing factors, such as FQs drug concentration, US irradiation time and solution temperature, on the inhibition of E.coli were also investigated. The antibacterial activity was enhanced apparently with increasing of FQs drug concentration, US irradiation time and solution temperature. Furthermore, we discussed preliminarily the mechanism of US ...
2011-01-01
Magnetic resonance imaging of chronic aortic dissection
International Nuclear Information System (INIS)
17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...
2010-01-01
Assessment of Low Quantitative Ultrasound Values of Calcaneus in Chinese Mainland Women
British Library Electronic Table of Contents (United Kingdom)
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
2010-01-01
International Nuclear Information System (INIS)
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...
2008-11-21
UK PubMed Central (United Kingdom)
This case report presents the prenatal diagnosis of conjoined twins at 7 weeks and 6 days’ gestation according to the last menstrual period and 6 weeks and 4 days’ gestation according...Full Text Available
Investigation of light elements in nitrided steel using elastic backscattering analysis
International Nuclear Information System (INIS)
This work describes the ability of ion beam analysis techniques IBA to simultaneously determine the concentration and the possible depth profile of some light elements, such as carbon, oxygen and nitrogen, in matrices of high atomic number Z, such as stainless steel materials. In fact, the nitriding process of some materials has the potential to improve their tribological and mechanical properties and to offer various advantages as compared with other methods used in the modification of surfaces. Gas and Plasma nitriding were applied to certain types of steel, such as AISI-304 and H-13 which are commonly used in the industry, in order to improve their hardness and their surface corrosion resistance. The improvement was correlated with the depth profile of N and the consequent structure variations. More specifically, non-Rutherford elastic backscattering (alpha, alpha) at 5 MeV was performed on different samples, before and after nitriding, in order to determine the ...
2006-08-01
International Nuclear Information System (INIS)
Measurements of absolute total cross sections for electron-impact excitation of Ar"7"+(3s#->#3p) using a merged-beams electron-energy-loss technique show that near threshold the inelastically scattered electrons are ejected primarily in the backward direction. This unusual angular scattering has not been previously observed for atoms or ions, but may be typical for multiply charged ions. The total cross sections, measured over an energy range to 2.2 eV above threshold, agree with seven-state R-matrix close-coupling calculations. Both close-coupling and distorted-wave calculations also confirm the backscattering observed in these measurements.
Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF
Energy Technology Data Exchange (ETDEWEB)
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
2004-04-01
International Nuclear Information System (INIS)
The tissue distribution of "1"3"1I-transferrin ("1"3"1I-Tf) was studied in athymic nude mice having s.c. human colonic adenocarcinoma HT-29 xenografts. Four days after "1"3"1I-Tf injection, the "1"3"1I specific activity measured in the HT-29 tumor, i.e. amount of radioactivity per gram of fresh tissue, represented 0.31 #+-# 0.09% of the injected radioactivity and was 1.90 fold more than that measured in the murine colon (P < 0.05). After correction for intravascular "1"3"1I-Tf as estimated by mean of "9"9"mTc-Sn in vivo labeling of red blood cells, the "1"3"1I specific activity observed in the HT-29 tumor was 7.21 fold more than that observed in the murine colon. This subtracting method enabled us to localize a HT-29 tumor xenograft by #gamma# scintigraphy of the entire animal and demonstrated that "1"3"1I-Tf could be a non-specific but potent marker for human colon cancer. (author).
Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System
Energy Technology Data Exchange (ETDEWEB)
RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} ...
1998-01-16
GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.
1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased from 8.0 to 12.5 per cent/day. 4. No differences were noted in the metabolism of homologous or autologous gamma globulin regardless of the allotypic ...
1964-04-01
International Nuclear Information System (INIS)
The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...
2003-06-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \\pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, ...
2003-01-01
Atrial natriuretic peptide receptor heterogeneity and effects on cyclic GMP accumulation
Energy Technology Data Exchange (ETDEWEB)
The effects of atrial natriuretic peptide (ANP), oxytocin (OT) and vasopressin (AVP) on guanylate cyclase activity and cyclic GMP accumulation were examined, since these hormones appear to be intimately associated with blood pressure and intravascular volume homeostasis. ANP was found to increase cyclic GMP accumulation in ten cell culture systems, which were derived from blood vessels, adrenal cortex, kidney, lung, testes and mammary gland. ANP receptors were characterized in intact cultured cells using {sup 125}I-ANP{sub 8-33}. Specific {sup 125}I-ANP binding was saturable and of high affinity. Scratchard analysis of the binding data for all cell types exhibited a straight line, indicating that these cells possessed a single class of binding sites. Despite the presence of linear Scatchard plots, these studies demonstrated that cultured cells possess two functionally and physically distinct ANP-binding sites. Most of the ANP-binding sites in cultured cells have a ...
1988-01-01
Transition of hydrated oxide layer for aluminum electrolytic capacitors
Energy Technology Data Exchange (ETDEWEB)
A hydrous oxide film for the application as dielectric film is synthesized by immersion of pure aluminum in hot water. From a Rutherford backscattering analysis, the ratio of aluminum to oxygen atoms was found to be 3:2 in the anodized aluminum oxide film, and 2:1 in the hydrous oxide layer. Anodization of the hydrous oxide layer was more effective for the transition of amorphous anodic oxides to the crystalline aluminum oxides.
2007-03-25
The idea of a compton-collider
Energy Technology Data Exchange (ETDEWEB)
A brief overview, from an experimentalist`s point of view, of the possibilities and difficulties involved in building a photon-photon collider using beams produced in Compton backscattering from a linear e{sup +}e{sup -} or e{sup -}e{sup -}collider. Some hindsight is included from the successful March 1994 Berkeley workshop on gamma-gamma colliders. (author). 13 refs., 2 figs.
1994-12-31
The idea of a compton-collider
International Nuclear Information System (INIS)
A brief overview, from an experimentalist's point of view, of the possibilities and difficulties involved in building a photon-photon collider using beams produced in Compton backscattering from a linear e"+e"- or e"-e"-collider. Some hindsight is included from the successful March 1994 Berkeley workshop on gamma-gamma colliders. (author). 13 refs., 2 figs.
Study of GaSb+Bi system by proton backscattering method
International Nuclear Information System (INIS)
The thermal stability of diffusion barriers is explored on the basis of Bi films at different expedients of deriving of films. The examinations were conducted on the electrostatic accelerator at KNU of name Karazin V.N. under conditions of an isothermal bakeout directly under a proton beam of 1,85 MeV energy.
Radioanalytical chemistry. Vol. 2
International Nuclear Information System (INIS)
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
1989-01-01
Principles of photon colliders
Energy Technology Data Exchange (ETDEWEB)
Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).
1995-02-01
Plasma lens formation in e{gamma} and {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).
1995-02-01
We developed a model for radar scattering from the lunar reoglith layer using vector radiative transfer theory. From this model, both the radar backscattering coefficient and the circular polarization ratio can be predicted analytically as a function of regolith parameters.
2010-03-01
Luminosity Upgrade of CLIC LHC ep/gp Collider
An energy frontier or QCD Explorer ep and collider can be realized by colliding high-energy photons generated by Compton backscattered off a CLIC electron beam, at either 75 GeV or 1.5 TeV, with protons or ions stored in the LHC. In this study we discuss a performance optimization of this type of collider by tailoring the parameters of both CLIC and LHC. An estimate of the ultimately achievable luminosity is given.
2007-01-01
Flucton - becoming and development of the conception
International Nuclear Information System (INIS)
Effect of proton backscattering on inelastic pd-scattering is discussed in detail. The discussion was carried out on the basis of interaction mechanism if bombarding particle with flucton. It is noted that fluctons are assumed presently as time multiquark formations of nuclear matter with the size of nucleon size order and density above nucleon one. 35 refs., 10 figs.
1993-01-27
International Nuclear Information System (INIS)
The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.
1993-01-01
An interface - marker technique applied to the study of metal silicide growth
International Nuclear Information System (INIS)
An interface-marker technique has been used to investigate the relative rates of diffusion of Si and of metal atoms during the growth of metal silicide films. The technique enables recognition of a reference plane in thin film diffusion using Rutherford backscattering, while minimizing any perturbation of the diffusion process. Examples are drawn from studies of the growth of silicides of W, Mo, Ta, Nb, Pd and Pt. (orig.).
A 3D tomographic EBSD analysis of a CVD diamond thin film
Energy Technology Data Exchange (ETDEWEB)
We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.
2008-09-15
Visualization of the salivary glands. CT and MRI
International Nuclear Information System (INIS)
For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...
MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA
Energy Technology Data Exchange (ETDEWEB)
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
1990-09-01
International Nuclear Information System (INIS)
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse scattering equation ...
2003-08-07
Idiopathic renal hematuria in a military working dog.
A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185
1992-10-01
International Nuclear Information System (INIS)
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...
2010-08-01
We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual SAR images shows that undulated corn crop canopies are well characterized by the mean contrast of the ...
2001-10-01
International Nuclear Information System (INIS)
Marker experiments for studying the mass transport through a palladium silicide layer on a crystalline substrate during thermal oxidation at 700 to 850 deg C have been reported recently. In this work argon gas embedded in amorphous silicon during sputtering was implemented as the inert marker and the oxidation of PdSi was processed above 900 deg C. At this high-temperature oxidation silicon-rich silicide PdSisub(y), with y exceeding 5, may be obtained. This can be anticipated by considering the Pd-Si phase diagram which shows the liquid phase may appear at an annealing temperature above 892 deg C. As a result, a non-stoichiometric and non-uniform silicide layer may develop at the sample surface. Marker analysis showed that both palladium and silicon dissociated at the Pdsub(x)Si/ SiO_2 interface and moved to the substrate with the silicon being the dominant diffuser. The Rutherford backscattering spectra (RBS) showing the oxide film and composition isothermally ...
Precise determination of H recoil cross sections for 1.5-3.0 MeV He ions
International Nuclear Information System (INIS)
The differential recoil cross sections of H have been determined for 1.5-3.0 MeV He"+ incidence. In order to obtain precise data, we have performed simultaneous detection and spectrum simulation of recoiled H and backscattered He. In addition, a careful cross check has been made by secondary ion mass spectrometry (SIMS). The present results have revealed a pronounced contribution from a nuclear short-range interaction. The He"+ energy and recoil angle dependence of the H recoil cross sections are well reproduced by adding the nuclear term, which is simply derived from effective range theory. Our computer simulation program of elastic recoil combined with Rutherford backscattering spectra makes it possible to determine the depth distributions of H together with other elements absolutely, without any ambiguities. The present elastic recoil analysis is employed to determine the H composition of amorphous Si(H) films deposited on Si wafers. An ...
MicroDiffraction in the Scanning Electron Microscope (SEM)
The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...
1997-12-31
Investigation of light elements in nitrided steel using elastic backscattering analysis
International Nuclear Information System (INIS)
This work describes the ability of ion beam analysis techniques IBA to simultaneously determine the concentration and the possible depth profile of some light elements, such as carbon, oxygen and nitrogen, in matrices of high atomic number Z, such as stainless steel materials. In fact, the nitriding process of some materials has the potential to improve their tribological and mechanical properties and to offer various advantages as compared with other methods used in the modification of surfaces. Gas and Plasma nitriding were applied to certain types of steel, such as AISI-304 and H-13 which are commonly used in the industry, in order to improve their hardness and their surface corrosion resistance. The improvement was correlated with the depth profile of N and the consequent structure variations. More specifically, non-Rutherford elastic backscattering (alpha, alpha) at 5 MeV was performed on different samples, before and after nitriding, in order to determine the ...
International Nuclear Information System (INIS)
Obtained experimental data on integral cross sections (ICS) of inelastic scattering of 50.5 MeV #alpha# particles with the excitation of "6","7Li, "9Be, "1"2","1"3C, "1"4C, "1"4N, "2"0Ne, "2"4Mg, "2"8Si nucleus low-lying energy levels are discussed. Regularities, detected in the behaviour of ICS forward scattering for 20-90 deg angles and backscattering for 90-160 deg angles for the target-nucleus under investigation are considered. Effect of reaction open channel number on #alpha#-particle scattering ICS where n,p,d- and #alpha#-channels were considered as the main channels for all the target-nuclei, is discussed. Dependence of #alpha#-particle scattering ICS on the target-nucleus level excitation energy and dependences of reaction open channel number on the channel spin, calculated for 50.5 MeV #alpha# particles and different target nuclei are shown in the diagrams. It is noted that the observed regularities in the #alpha#-particle inelastic scattering ICS are ...
Edge filter and fringe imaging for laser Doppler wind speed measurement
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of complicating factors such as solar ...
1997-08-01
Transverse polarization of top quarks produced at a photon-photon collider
Energy Technology Data Exchange (ETDEWEB)
At future {gamma} {gamma} colliders a massive production of tt-bar pairs is possible. This would allow a detailed investigation of the interactions involving the top quark. The authors propose some correlations which are sensitive to tt-bar final state interactions and compute the QCD and standard model Higgs boson contributions to these correlation. QCD-induced transverse polarization of top quarks is found to be sizeable and measurable at a high-energy e{sup +} e{sup -} collider with an integrated luminosity of 10(fb){sup -1} which is converted into a photon collider by backscattering of laser photons. 16 refs.
1995-10-01
Transverse polarization of top quarks produced at a photon-photon collider
International Nuclear Information System (INIS)
At future #gamma##gamma# colliders copious production of t bar t pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to t bar t final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy e"+e"- collider, which is operated as a photon collider through backscattering of laser photons, at an integrated luminosity of 10 fb"-"1.
The interaction of fast N"+_2 ions with a Ni(111) surface
International Nuclear Information System (INIS)
In the context of sputtering experiments, studying the back-scattering of fast ion beams is a useful way to study inelastic ion-surface interactions, since then the trajectories and energies of the particles are well defined. This same argument holds for the scattering of fast molecular ions. We give a short account of our experiment where N"+_2 was scattered from a Ni(111) surface. The measured energy distributions of scattered N atoms are discussed with regard to vibrational and rotational energy transfer during scattering. (G.Q.).
1986-02-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
The chemical properties of alloys in a given environment are to a large extent governed by the surface composition. Changes of the surface composition during passivation are important features in this respect. Previous studies of single crystal Ni-Mo alloys surfaces have been reported. The aim of this work was to obtain quantitative data, for the natural oxide and the passive films formed on Ni-6% Mo(100) and (110) alloys, using Rutherford backscattering spectroscopy and nuclear reaction analysis.
1988-07-01
International Nuclear Information System (INIS)
The chemical properties of alloys in a given environment are to a large extent governed by the surface composition. Changes of the surface composition during passivation are important features in this respect. Previous studies of single crystal Ni-Mo alloys surfaces have been reported. The aim of this work was to obtain quantitative data, for the natural oxide and the passive films formed on Ni-6% Mo(100) and (110) alloys, using Rutherford backscattering spectroscopy and nuclear reaction analysis. (author).
1987-10-19
Solid state and materials research
International Nuclear Information System (INIS)
Within about 10 years, microelectronic devices will be made with more than a billion (10"9) electronic components per chip. To implement such a sophisticated technology it will be essential to have a fundamental understanding of the solid state interaction between the different materials in thin film semiconductor structures. This is the main purpose of this research program. Characterization and analysis is carried out mainly by Rutherford backscattering spectrometry and channelling using accelerated nuclear particles from the Van de Graaff accelerator, while radioactive isotopes provide information about interaction mechanisms. 6 figs., 1 ref.
Silicidation in Pd/Si thin film junction-Defect evolution and silicon surface segregation
Energy Technology Data Exchange (ETDEWEB)
Depth resolved positron annihilation studies on Pd/Si thin film system have been carried out to investigate silicide phase formation and vacancy defect production induced by thermal annealing. The evolution of defect sensitive S-parameter clearly indicates the presence of divacancy defects across the interface, due to enhanced Si diffusion beyond 870 K consequent to silicide formation. Corroborative glancing incidence X-ray diffraction (GIXRD), Auger electron spectroscopy (AES) and Rutherford backscattering spectrometry (RBS) have elucidated the aspects related to silicide phase formation and Si surface segregation.
2007-09-25
RBS Characterization of Yttrium Iron Garnet Thin Films
International Nuclear Information System (INIS)
Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)
2008-12-13
Quasi-elastic electron scattering by GaAs surface
International Nuclear Information System (INIS)
Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).
1994-03-20
Microstructure, texture and mechanical properties of the magnesium alloy AZ31 processed by ECAP
Energy Technology Data Exchange (ETDEWEB)
To investigate the influence of equal channel angular pressing on the microstructure and texture of the magnesium alloy AZ31, electron backscattering diffraction and well as neutron diffraction experiments were carried out. Through these experiments it was possible to trace the microstructure and texture evolution with strain accumulated with the increasing number of equal channel angular pressing passes. It was further demonstrated by subsequent compression tests that the microstructural changes produced by equal channel angular pressing have a beneficial effect on both the compressive strength and ductility of AZ31. (orig.)
2008-01-15
Micropulse Lidar (MPL) Handbook
Energy Technology Data Exchange (ETDEWEB)
The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.
2006-05-01
Ion beam crystallography of metal-silicon interfaces: Pd-Si(111)
Energy Technology Data Exchange (ETDEWEB)
The application of medium energy ion scattering in combination with channelling and blocking to the study of the initial stages of palladium silicide formation is discussed. After a brief description of the experimental arrangement and method, the effects on the Rutherford backscattering spectra of depositing small quantities of palladium on clean Si(111) are reported. The uniformity and thermal stability of thin palladium silicide films grown at room temperature were measured. Finally, channelling and blocking results were used to carry out a structural analysis of thin epitaxial Pd/sub 2/Si layers.
1982-07-09
Ion beam crystallography of metal-silicon interfaces: Pd-Si(111)
International Nuclear Information System (INIS)
The application of medium energy ion scattering in combination with channelling and blocking to the study of the initial stages of palladium silicide formation is discussed. After a brief description of the experimental arrangement and method, the effects on the Rutherford backscattering spectra of depositing small quantities of palladium on clean Si(111) are reported. The uniformity and thermal stability of thin palladium silicide films grown at room temperature were measured. Finally, channelling and blocking results were used to carry out a structural analysis of thin epitaxial Pd_2Si layers. (Auth.).
Ion beam analysis of high temperature superconducting samples
Energy Technology Data Exchange (ETDEWEB)
Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).
1994-02-01
High intensity lasers for gamma-gamma colliders
International Nuclear Information System (INIS)
Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
Gamma-gamma collider based on Compton back-scattering
International Nuclear Information System (INIS)
A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.
1996-08-25
International Nuclear Information System (INIS)
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
Effect of deformation on corrosion behavior of Ti-23Nb-0.7Ta-2Zr-O alloy
International Nuclear Information System (INIS)
The influence of deformation on the corrosion behavior of a newly developed multifunctional beta titanium alloy Ti-23Nb-0.7Ta-2Zr-O (mol%) in Ringer's solution at 310 K was evaluated using an electron backscatter diffraction technique and electrochemical measurements. The results showed that the effect of deformation on the corrosion resistance of the beta titanium alloy is complicated. Small levels of plastic deformation are detrimental to the corrosion resistance, whereas large deformations tend to eliminate this detrimental effect.
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
A new band gap profile (exponential profile) for the active layer of the a-SiGe:H single junction cell has been designed and experimentally demonstrated. By computer simulations we show how bending the grading of the band gap in the i-layer contributes to the enhancement of the carrier collection, improving the fill factor and efficiency. The differences observed between experiments and simulations are studied using Rutherford Backscattering Spectrometry (RBS). The results highlight weak points during the deposition process, whose control enables us to bring together experimental and computational results.
2004-01-25
International Nuclear Information System (INIS)
Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage
International Nuclear Information System (INIS)
The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...
2005-04-01
The use of SMARTeR stents in patients with biliary obstruction
Energy Technology Data Exchange (ETDEWEB)
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
2004-03-01
Temperature and time-dependence of the elastic moduli of Pu and Pu-Ga alloys
International Nuclear Information System (INIS)
In previous work, on cooling from 300 K to 10 K the elastic moduli for both #alpha#- and #delta#-Pu dropped 30%. This large change may reflect effects of 5f-electron localization. In this work, the elastic moduli at ambient temperature of several Pu-Ga alloys were measured using resonant ultrasound spectroscopy (RUS). The strong temperature dependence of the bulk and shear modulus and the temperature independence of Poisson's ratio was confirmed and the upper temperature limit for #alpha#-Pu was extended to 360 K. Measurements of the time dependence of the shear moduli of Pu and Pu-2.36 at.% Ga were determined with high precision as a function of time and temperature. Using a model for time dependence of point defects, we determined the exponential time constant at ambient temperature for such variations. The low temperature results are consistent with Fluss .
2007-10-11
Solid suspension in stirred tanks: UVP measurements and CFD simulations
British Library Electronic Table of Contents (United Kingdom)
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
2011-01-01
Real time automatic discriminating of ultrasonic flaws
International Nuclear Information System (INIS)
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)
2009-07-20
Perioperative Care of a Child with Transposition of the Great Arteries
British Library Electronic Table of Contents (United Kingdom)
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
2011-01-01
MRI imaging of fetal neck masses with airway compromise: utility in delivery planning
International Nuclear Information System (INIS)
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
2001-10-01
Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases
British Library Electronic Table of Contents (United Kingdom)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.
2011-01-01
Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development
International Nuclear Information System (INIS)
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. ...
2002-08-01
Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology
Energy Technology Data Exchange (ETDEWEB)
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
1994-02-01
British Library Electronic Table of Contents (United Kingdom)
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
2008-01-01
A Study on TOFD Inspection Using Phased Array Ultrasonic Technique
Energy Technology Data Exchange (ETDEWEB)
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry
2005-08-15
Understanding feline heartworm infection: disease, diagnosis, and treatment.
Feline heartworm disease is a very different clinical entity from canine heartworm disease. In cats, the arrival and death of immature heartworms in the pulmonary arteries can cause coughing and dyspnea as early as 3 months postinfection. Adult heartworms suppress the function of pulmonary intravascular macrophages and thus reduce clinical disease in chronic feline heartworm infection. Approximately 80% of asymptomatic cats self-cure. Median survival time for symptomatic cats is 1.5 years, or 4 years if only cats living beyond the day of presentation are considered. Aberrant worm migration is more frequent than it is in dogs, and sudden death can occur with no prior clinical signs. The bacterial endosymbiont Wolbachia likely contributes to the inflammatory pathology of heartworm disease, but its role is not yet fully clear. Unfortunately, the diagnosis, treatment, and management of feline heartworm disease are far from simple. Antemortem diagnosis is hampered by ...
2010-11-01
Pathogenesis of trypanosome infections in cattle
International Nuclear Information System (INIS)
The potential application of radioisotopes are not discussed in this review of trypanosome pathogenesis in cattle. Initially, structural changes in the lymphoid system are characterized by marked proliferation and germinal centre formation, whereas in long-standing infections the lymphoid organs become depleted. These changes appear associated with immunodepression. Anaemia dominates the clinical disease syndrome in bovine trypanosomiasis. It develops with the onset of parasitaemia and is largely haemolytic, resulting from increased red blood cell destruction by phagocytosis. Several factors may be involved in this process including haemolysins produced by the trypanosome, immunological mechanisms, fever, disseminated intravascular coagulation and an expanded and active mononuclear phagocytic system. During this phase of the disease, cattle respond well to chemotherapy. However, in later phases of the disease, when trypanosomes cannot be detected, the anaemia ...
1979-05-11
An experimental study on lipiodol chemoembolization in the normal dog liver
Energy Technology Data Exchange (ETDEWEB)
The hepatic artery chemoembolization with Lipiodol, doxorublicin. Gelfoam was performed in 14 mongrel dogs to evaluate embolic effect of these materials to normal liver parenchyma. Fourteen dogs were divided into four experimental groups according to the kinds of embolic materials. 3 dogs with 0.1ml/kg of Lipiodol (Group 1), 4 dogs with 0.1ml/kg of Lipiodol and 0.5mg/kg of doxorubicin (Group 2). 4 dogs with Lipiodol, doxorubicin and 150-300 pieces of 0.5 x 0.5cm sized Gelfoam (Group 3), 3 dogs with Gelfoam alone (Group 4). Follow-up liver function tests and liver CT were performed 1 day, 3 day, 1 week, 2 weeks and 3 weeks after embolization. Pathologic examination was performed 3 weeks after embolization. Lipiodol densities in group 1 were cleared 2 weeks after embolization, and in group 2, patch and nodular Lipiodol densities were changed to mottled and streaky densities 3 weeks after chemoembolization. In group 3, patch and nodular Lipiodol densities were still remained 3 weeks after ...
1991-01-15
Tetracycline hydrochloride sclerotherapy; renal, hepatic, ovarian, and perivesical cysts
Energy Technology Data Exchange (ETDEWEB)
To assess the efficacy and resulting complications of tetracycline sclerotherapy in renal, hepatic, ovarian, and perivesical cysts. We retrospectively reviewed 23 cases of benign cysts (16 renal, 4 hepatic, 2 ovarian, and 1 perivesical) in 22 patients in whom the condition was diagnosed or confirmed by either ultrasound, CT, or cytology, and who underwent percutaneous tetracycline sclerotherapy. Using a 21-gauge Chiba needle, the target cyst was punctured under ultrasound guidance. Prior to the injection of 1500 mg of tetracycline diluted in 5 ml of normal saline, almost all the cystic content was aspirated, and at the end of the procedure the tetracycline was left in the cyst. During a period of between 3 and 22 months, 18 of the 23 cases were followed up. In six of the 18 cases followed up, the cysts either decreased in size by 10%, or collapsed completely. In seven cases a collapse of over 50% was noted, and in the remaining five the cyst ...
2000-11-01
MRI-based N-staging in esophageal cancer
International Nuclear Information System (INIS)
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by two radiologists. ...
2002-10-01
International Nuclear Information System (INIS)
The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The ...
DEFF Research Database (Denmark)
Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 disease at ...
2008-01-01
Carpal tunnel syndrome (CTS) is a common disorder, for which various conservative treatment options are available. The objective of this study is to determine the efficacy of the various conservative treatment options for relieving the symptoms of CTS. Computer-aided searches of MEDLINE (1/1966 to 3/2000), EMBASE (1/1988 to 2/2000) and the Cochrane Controlled Trials Register (2000, issue 1) were conducted, together with reference checking. Included were randomised controlled trials evaluating the efficacy of conservative treatment options in a study population of CTS patients, with a full report published in English, German, French or Dutch. Two reviewers independently selected the studies. Fourteen randomised controlled trials were included in the review. Assessment of methodological quality and data-extraction was independently performed by two reviewers. A rating system, based on the number of studies and their methodological quality and findings, was used to determine the strength ...
2002-03-01
Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets
International Nuclear Information System (INIS)
Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.
2011-05-15
Three-dimensional elastic lidar winds
Energy Technology Data Exchange (ETDEWEB)
Maximum cross-correlation techniques have been used with satellite data to estimate winds and sea surface velocities for several years. Los Alamos National Laboratory (LANL) is currently using a variation of the basic maximum cross-correlation technique, coupled with a deterministic application of a vector median filter, to measure transverse winds as a function of range and altitude from incoherent elastic backscatter lidar data taken throughout large volumes within the atmospheric boundary layer. Hourly representations of three- dimensional wind fields, derived from elastic lidar data taken during an air-quality study performed in a region of complex terrain near Sunland Park, New Mexico, are presented and compared with results from an Environmental Protection Agency (EPA) approved laser doppler velocimeter. The wind fields showed persistent large scale eddies as well as general terrain following winds in the Rio Grande valley.
1996-07-01
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of ...
2009-09-01
The influence of target backing on ion-beam electron spectra
International Nuclear Information System (INIS)
Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).
Tantalum nitride as a diffusion barrier between Pd_2Si or CoSi_2 and aluminum
International Nuclear Information System (INIS)
Reactively sputtered tantalum nitride (Ta_2N) has been investigated as a diffusion barrier between Pd_2Si and aluminum and CoSi_2 and Al. Ta_2N is found to be an excellent matallurgical diffusion barrier for the two systems up to 555 "0C, with no intermixing observed in Rutherford backscattering and Auger electron spectroscopic studies. Schottky barrier devices n-Si/Pd_2Si/Ta_2N/Al were excellent and showed no deterioration after annealing at 500 "0C. However, similar devices with CoSi_2 contacts and Ta_2N barrier showed a creation of high contact resistance between the silicide and the as-deposited nitride.
Tantalum nitride as a diffusion barrier between Pd/sub 2/Si or CoSi/sub 2/ and aluminum
Energy Technology Data Exchange (ETDEWEB)
Reactively sputtered tantalum nitride (Ta/sub 2/N) has been investigated as a diffusion barrier between Pd/sub 2/Si and aluminum and CoSi/sub 2/ and Al. Ta/sub 2/N is found to be an excellent matallurgical diffusion barrier for the two systems up to 555 /sup 0/C, with no intermixing observed in Rutherford backscattering and Auger electron spectroscopic studies. Schottky barrier devices n-Si/Pd/sub 2/Si/Ta/sub 2/N/Al were excellent and showed no deterioration after annealing at 500 /sup 0/C. However, similar devices with CoSi/sub 2/ contacts and Ta/sub 2/N barrier showed a creation of high contact resistance between the silicide and the as-deposited nitride.
1989-04-15
Study on the solid state reaction between bilayered Pd/Au films and silicon substrates
British Library Electronic Table of Contents (United Kingdom)
Bilayers of pure palladium and gold films were evaporated alternatively on (100) and (111) monocrystalline silicon substrates. After annealing, in a vacuum furnace from 100 to 650degreeC during 30min, the growth sequence of the Pd2Si and PdSi phases that evolved as the result of the diffusion reaction was examined by means of Rutherford backscattering spectrometry (RBS), X-ray diffraction (XRD), whereas the surface morphology was investigated by scanning electron microscopy (SEM) technique. The effect of the intermediate gold layer is investigated in order to test its effectiveness as barrier for Cu and Si atoms interdiffusion and its influence on the morphology of the formed palladium silicides. The effect of substrate orientation on the palladium silicides growth and formation was also e...
2006-01-01
Study of Zircaloy-2 corrosion in high temperature water using ion beam methods
Energy Technology Data Exchange (ETDEWEB)
Experiments have been carried out in water at 355 C to study transport of oxygen and hydrogen (as deuterium) in growing corrosion films. Composition of the films was also examined in 2.9 Mev and 3.9 Mev /alpha/-particle backscattering experiments. Corrosion occurs predominantly by oxygen diffusion through the film via grain boundary or similar short circuit diffusion paths, to form fresh oxide at the oxide metal interface. Increasing grain size within thick pre-breakaway films contributes to a decrease in diffusivity. The rate transition results from the generation of new diffusion pathways in previously protective oxide. Unexpectedly high concentrations of deuterium were observed. 26 refs.
1981-10-01
International Nuclear Information System (INIS)
We have studied the ion-beam synthesis of GaSb nanocrystals in Si by high-fluence '' hot '' implantation of Sb and Ga ions followed by thermal annealing. The Rutherford backscattering, transmission electron microscopy/transmission electron diffraction, Raman spectroscopy and photoluminescence were used to characterize the implanted layers. It was found that the nanocrystal size increases from 5 to 60 nm in the samples annealed at 900"oC up to 20-90 nm in those annealed at 1100"oC. For the samples annealed at 900"oC a broad band in the region of 0.75-1.05 eV is registered in the photoluminescence spectra. The nature of this photoluminescence band is discussed. (author)
2011-07-01
International Nuclear Information System (INIS)
The purpose of this experimental study is to investigate the micromechanical fatigue behavior, in terms of slip nature and preferential cracking sites, of a commercial #alpha#/#beta#-forged Ti-6Al-4V alloy. Electron backscattering diffraction is extensively used to identify the deformation (prismatic, basal, pyramidal slip) and crack formation modes activated by fatigue at the surface of several hundred primary #alpha# nodules. Some fatal crack formation sites are also characterized. Cracking in basal planes is identified as the most critical damage mode leading to fracture. An explanation is proposed which involves the resolved shear stress, taking into account the Schmid factor and the normal stress in relation to the elastic anisotropy of the #alpha#-phase. Finally, the spatial distribution of the secondary cracks is analyzed according to the crystallographic textures (macrozones) present on a mesoscopic scale in the Ti-6Al-4V alloy.
2008-09-01
Self-diffusion of silicon in thin films of cobalt, nickel, palladium and platinum silicides
International Nuclear Information System (INIS)
Radioactive "3"1Si was used as a tracer to study silicon self-diffusion in thin film silicides of cobalt, nickel, palladium and platinum. The specimens were prepared by sequential electron beam evaporation of radioactive "3"1Si and of the metal onto cleaned silicon wafers. By vacuum annealing at the appropriate formation temperature a silicide about 250 nm thick containing a sharp radioactive band about 50 nm thick was generally formed. Subsequent heating above the formation temperature resulted in a spreading of the activity owing to silicon self-diffusion. Activity profiles in the silicides were measured by a combination of ion beam sputtering, radioactivity counting and Rutherford backscattering of charged nuclear particles. (orig.).
Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD
Energy Technology Data Exchange (ETDEWEB)
This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.
1994-12-31
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Redistribution of implanted dopants after metal-silicide formation
The redistribution of implanted As and Sb following metal-silicide formation of Pt, Pd, and Ni has been studied. The phases of the silicides used were PtSi, Pd/sub 2/Si, and NiSi. Investigations with Rutherford backscattering analysis showed that after the formation of the silicides, the Sb was always found in the silicide layer near the surface of the samples, whereas PtSi and Pd/sub 2/Si caused a partial rejection of As for implanted doses of 2 x 10/sup 15/ cm/sup -2/ and higher. No rejection of As was found after the formation of NiSi. The results are discussed in terms of solid solubilities and impurity-metal compound formation. The data presented has implications in the fabrication of Ohmic contacts and the adjustments of the heights of Schottky barriers on silicon.
1978-12-01
Redistribution of implanted dopants after metal-silicide formation
International Nuclear Information System (INIS)
The redistribution of implanted As and Sb following metal-silicide formation of Pt, Pd, and Ni has been studied. The phases of the silicides used were PtSi, Pd_2Si, and NiSi. Investigations with Rutherford backscattering analysis showed that after the formation of the silicides, the Sb was always found in the silicide layer near the surface of the samples, whereas PtSi and Pd_2Si caused a partial rejection of As for implanted doses of 2 x 10"1"5 cm"-"2 and higher. No rejection of As was found after the formation of NiSi. The results are discussed in terms of solid solubilities and impurity-metal compound formation. The data presented has implications in the fabrication of Ohmic contacts and the adjustments of the heights of Schottky barriers on silicon.
Phase formation sequence in the Pd-GaAs system
Energy Technology Data Exchange (ETDEWEB)
The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.
1985-12-01
Observation of Spontaneous Brillouin Cooling
While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, a Brillouin cooling regime. Cooling is mediated by an optical ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.
2008-01-01
International Nuclear Information System (INIS)
Inert markers (evaporated tungsten and silver) were used in growth studies of silicides formed both by thermal annealing and by ion mixing in the Ni/Si, Pd/Si, and Cr/Si systems. The markers were initially imbedded inside silicides and backscattering spectrometry was used to determine the marker displacement after different processing conditions. The results obtained in thermal annealing are quite consistent with that found in previous investigations. Ni is the dominant diffusing species in Ni_2Si, while Si is the diffusing species in CrSi_2. In Pd_2Si, both Pd and Si are moving species with Pd the faster of the two. In contrast, in growth of silicides by ion irradiation Si is the faster diffusing species in all three systems.
Energy Technology Data Exchange (ETDEWEB)
Inert markers (evaporated tungsten and silver) were used in growth studies of silicides formed both by thermal annealing and by ion mixing in the Ni/Si, Pd/Si, and Cr/Si systems. The markers were initially imbedded inside silicides and backscattering spectrometry was used to determine the marker displacement after different processing conditions. The results obtained in thermal annealing are quite consistent with that found in previous investigations. Ni is the dominant diffusing species in Ni/sub 2/Si, while Si is the diffusing species in CrSi/sub 2/. In Pd/sub 2/Si, both Pd and Si are moving species with Pd the faster of the two. In contrast, in growth of silicides by ion irradiation Si is the faster diffusing species in all three systems.
1985-08-15
Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects
Energy Technology Data Exchange (ETDEWEB)
By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.
1985-01-11
Ion-induced phase formation in metal-silicon systems
International Nuclear Information System (INIS)
By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).
Influence of annealing on the microstructure of commercial Mg alloy AZ31 after mechanical forming
International Nuclear Information System (INIS)
The microstructure of commercial rolled magnesium alloy AZ31B (nominal composition Mg-3Al-0.9Zn-0.15Mn in wt.%) was investigated with the help of light microscopy, electron backscatter diffraction (EBSD) and X-ray diffraction technique after annealing in the temperature range from room temperature (RT) to 400 deg. C. Tensile tests at RT were performed to show the influence of the microstructure on mechanical properties. Static recrystallization (SRX) was observed during annealing of as-received alloy at and above 150 deg. C. Twins play an important role during SRX and serve as nucleation sites and preferred paths for growth of grains. The strong basal texture caused by rolling was weakened by SRX. Significant differences in the stress strain curves were observed for as-received and annealed specimens.
2006-09-25
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
Energy Technology Data Exchange (ETDEWEB)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
International Nuclear Information System (INIS)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
High intensity lasers for gamma-gamma colliders
Energy Technology Data Exchange (ETDEWEB)
Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
1995-02-01
High energy photon-photon collisions
International Nuclear Information System (INIS)
The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, such as the scaling of the photon structure function, tt production, mini-jet ...
Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films
Energy Technology Data Exchange (ETDEWEB)
Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.
1982-06-11
Growth meachnisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films
Energy Technology Data Exchange (ETDEWEB)
Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.
1982-06-11
Feathery grain growth during solidification under forced flow conditions
British Library Electronic Table of Contents (United Kingdom)
The grain morphology developed during solidification of an Al-4.5% Cu alloy is represented generally by columnar or equiaxed dendrites. Twinned feathery grains are found in the structure formed under certain heat and flow conditions during solidification. In this work, these conditions were achieved during solidification in a cavity under forced flow. Feathery grain formation is studied by means of fluid dynamics simulations with solidification included and by experiments. In order to determine the crystallographic orientation of feathery grains, electron backscattered diffraction measurements were performed. The growth features of feathery grains were analyzed by observations made normal and parallel to the growth direction. Some correlations between twinned feathery morphology, flow and ...
2007-01-01
International Nuclear Information System (INIS)
Up to 90% of the life time of cyclically loaded components is determined by short crack initiation and propagation. This stage of the fatigue damage process is strongly influenced by microstructural features, e.g. grain boundaries and crystallographic grain orientation. Therefore LEFM can not be applied in a reasonable manner explaining the demand for a mechanism-related modelling method. The present study deals with mechanical testing and microstructural examinations applied to the relatively new #beta#-titanium alloy LCB. The results are used as data base to develop a new short crack model that is based on the model of Navarro and de los Rios. By using various techniques such as electron back-scattered diffraction and finite-element calculations the origin of crack initiation is revealed and the characteristics of crack propagation is determined. (orig.)
2000-02-24
The phase stability of silicides of Ni, Pt and Pd in contact with single crystal or amorphous silicon is examined. The presence of a particular silicide phase is identified by X-ray diffraction, and Rutherford backscattering is used to study composition. It is concluded that Pt or Pd silicides are suitable for Schottky barriers. Layers of silicon can be grown quickly by solid phase epitaxy at temperatures of 300-500C and using an intermediate metal film. Experimental results are reported. Doped layers have been obtained which have electrical characteristics suitable for the junctions in solar cells. The effects of impurities and orientation of the substrate on the growth kinetics are discussed.
Diffusion of antimony in silicon in the presence of point defects
Energy Technology Data Exchange (ETDEWEB)
We have investigated the diffusion of Sb in Si in the presence of defects injected by high-energy implantation of Si ions at room temperature. MeV ion implantation increases the concentrations of vacancies, which induce transient-enhanced diffusion of Sb deposited in Si. We observed a significant enhancement of Sb diffusion. Secondary ions mass spectroscopy has been performed on the implanted samples before and after annealing. Rutherford-backscattering spectrometry has been used to characterize the high-energy implantation damage. By fitting diffusion profiles to a linear diffusive model, information about atomic scale diffusion of Sb, i.e. the generation rate of mobile state Sb and its mean migration length were extracted.
2007-08-15
Diffusion of antimony in silicon in the presence of point defects
International Nuclear Information System (INIS)
We have investigated the diffusion of Sb in Si in the presence of defects injected by high-energy implantation of Si ions at room temperature. MeV ion implantation increases the concentrations of vacancies, which induce transient-enhanced diffusion of Sb deposited in Si. We observed a significant enhancement of Sb diffusion. Secondary ions mass spectroscopy has been performed on the implanted samples before and after annealing. Rutherford-backscattering spectrometry has been used to characterize the high-energy implantation damage. By fitting diffusion profiles to a linear diffusive model, information about atomic scale diffusion of Sb, i.e. the generation rate of mobile state Sb and its mean migration length were extracted.
2007-08-01
Automated three-dimensional X-ray analysis using a dual-beam FIB
International Nuclear Information System (INIS)
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
2007-08-01
Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface
Energy Technology Data Exchange (ETDEWEB)
Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.
1989-01-01
International Nuclear Information System (INIS)
The gliding modes of a duplex Ti-6Al-4V titanium alloy were investigated through in situ (scanning electron microscopy) tensile tests. A method based on electron back-scattering diffraction (EBSD) measurements was used to identify activated slip systems. The approach applied to a large number of grains allowed a statistical analysis of the nature (basal, prismatic, pyramidal) and distribution of the slip systems according to the crystallographic texture. A discussion concerning the pertinence of Schmid's law to explain the occurrence and succession of slip events is then proposed. The domain in favor of each type of slip system is finally presented by using inverse pole figures mapped with Schmid's factor iso-curves.
2005-02-01
64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate ...
2006-04-15
The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV ...
2002-01-01
[Natural course of asymptomatic gallstone disease].
Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...
1993-07-01
The safety issues of medical robotics
International Nuclear Information System (INIS)
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical ...
2001-08-01
Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report
International Nuclear Information System (INIS)
The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...
Percutaneous drainage of abdominal abcess
Energy Technology Data Exchange (ETDEWEB)
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. Percutaneous routes that ...
2002-09-01
Opto-acoustic recanilization delivery system
Energy Technology Data Exchange (ETDEWEB)
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the ...
2002-01-01
Is intraoperative ultrasound (IOUS) still useful for the detection of liver metastases?
British Library Electronic Table of Contents (United Kingdom)
SommarioScopo Valutare limpatto clinico negli anni dellecografia intraoperatoria (IOUS) nella identificazione delle metastasi epatiche rispetto alle altre metodiche di imaging. Materiali e metodi risultati delle ecografie intraoperatorie effettuate per lidentificazione delle metastasi epatiche in un periodo compreso tra gli anni 2000 e 2006 sono stati retrospettivamente revisionati e comparati con le metodiche di imaging preoperatorio: Ecografia (US), Tomografia Computerizzata (TC) e/o Risonanza Magnetica (RM). Tutti i casi sono stati patologicamente provati. Sono stati calcolati per anno i casi discordanti in termini di presenza/assenza di lesione focale epatica. Il confronto statistico e stato effettuato con il test di McNemar. Un valore del p<0,05 e stato considerato statisticamente sig...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
1999-10-01
Energy Technology Data Exchange (ETDEWEB)
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver ...
2000-02-01
Using ERS-2 SAR images for routine observation of marine pollution in European coastal waters
Energy Technology Data Exchange (ETDEWEB)
More than 660 synthetic aperture radar (SAR) images acquired over the southern Baltic Sea, the North Sea, and the Gulf of Lyon in the Mediterranean Sea by the Second European Remote Sensing Satellite (ERS-2) have been analyzed since December 1996 with respect to radar signatures of marine pollution and other phenomena causing similar signatures. First results of our analysis reveal that the seas are most polluted along the main shipping routes. SAR images acquired during descending (morning) and ascending (evening) satellite passes show different percentages of oil pollution, because most of this pollution occurs during night time and is still visible on the SAR images acquired in the morning time. Moreover, we found a higher amount of oil spills on SAR images acquired during summer (April-September) than on SAR images acquired during winter (October-March). We attribute this finding to the higher mean wind speed encountered in all three test areas during winter. By using an ERS-2 SAR ...
1999-09-30
Turnover of texture in low rate sputter-deposited nanocrystalline molybdenum films
International Nuclear Information System (INIS)
The crystallite size and orientation in molybdenum films prepared by magnetron sputtering at a low rate of typical 1 (angstrom)s and a pressure of 0.45 Pa was investigated by X-ray diffraction and texture analysis. The surface topography was studied using atomic force microscopy. Increasing the film thickness from 20 nm to 3 microm, the films show a turnover from a (110) fiber texture to a (211) mosaic-like texture. In the early state of growth (20 nm thickness) the development of dome-like structures on the surface is observed. The number of these structures increases with film thickness, whereas their size is weakly influenced. The effect of texture turnover is reduced by increasing the deposition rate by a factor of six, and it is absent for samples mounted above the center of the magnetron source. The effect of texture turnover is related to the bombardment of the films with high energetic argon neutrals resulting from backscattering at the target under oblique ...
1997-04-04
Energy Technology Data Exchange (ETDEWEB)
Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLT test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLT test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.
1992-07-01
Study of iodine migration in zirconia using stable and radioactive ion implantation
Energy Technology Data Exchange (ETDEWEB)
The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using radioactive {sup 131}I ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
SiO/sub 2//Si samples prepared in 2% and 4% HCl/O/sub 2/ mixtures at 1200/sup 0/C have been annealed in H/sub 2/O/N/sub 2/ ambients at 1200/sup 0/C. The anneals ranged up to 16 hrs in ambients with 4 or 40 ppM H/sub 2/O in N/sub 2/. Rutherford backscattering measurements have been made to determine the amount and location of Cl incorporated in these samples. A linear loss of Cl with annealing time is found for all samples. Changes in the distribution of Cl near the SiO/sub 2//Si interface are found. These changes are interpreted in terms of morphological changes in the third (Cl containing) phase. A significant effect of the H/sub 2/O content of the N/sub 2/ ambient is observed.
1980-01-01
Radiation-enhanced diffusion in amorphous Pd-Cu-Si
Energy Technology Data Exchange (ETDEWEB)
Diffusion during He/sup +/, Ne/sup +/, and Xe/sup +/ irradiations of trace amounts of Au in melt-spun amorphous Pd/sub 78/Cu/sub 6/Si/sub 16/ has been experimentally investigated. Diffusion constants were measured by following the changes in ion-implanted Au profiles with Rutherford-backscattering spectrometry. Heat treatments and simultaneous irradiations were performed as a function of temperature (533--588 K), ion flux, and ion mass. Total integrated fluences being very small, ion-beam-mixing effects are negligible. More than an order of magnitude enhancement in the diffusion was observed because of irradiations. This enhancement saturates at higher fluxes, the level being independent of ion mass, i.e., independent of collision-cascade parameters. Except at higher temperatures, where the enhancement decreases, the temperature dependence of the diffusion-saturation level is similar to that of the diffusion without irradiation. The data suggest that vacancylike ...
1988-11-01
Radiation-enhanced diffusion in amorphous Pd-Cu-Si
International Nuclear Information System (INIS)
Diffusion during He"+, Ne"+, and Xe"+ irradiations of trace amounts of Au in melt-spun amorphous Pd/sub 78/Cu_6Si/sub 16/ has been experimentally investigated. Diffusion constants were measured by following the changes in ion-implanted Au profiles with Rutherford-backscattering spectrometry. Heat treatments and simultaneous irradiations were performed as a function of temperature (533--588 K), ion flux, and ion mass. Total integrated fluences being very small, ion-beam-mixing effects are negligible. More than an order of magnitude enhancement in the diffusion was observed because of irradiations. This enhancement saturates at higher fluxes, the level being independent of ion mass, i.e., independent of collision-cascade parameters. Except at higher temperatures, where the enhancement decreases, the temperature dependence of the diffusion-saturation level is similar to that of the diffusion without irradiation. The data suggest that vacancylike defects play a ...
Polypropylene surface modification by active screen plasma nitriding
International Nuclear Information System (INIS)
Here we describe the use of low energy plasma immersion with active screen as a convenient approach for polypropylene (PP) surface modification. Employing a stainless steel cathodic cage coated with carbon in order to prevent the sputtering of iron from the grid and its deposition onto the polymer sample, the physical chemical properties of PP surface could be effectively modified through the plasma-induced incorporation/formation of nitrogen- and oxygen-containing species. The areal densities of these elements depended on the plasma excitation source, as determined by Rutherford backscattering spectrometry (RBS). Newly formed C-O, C-N, and C=O/O=C-O/N-C=O bonds along with C-C linkages from the PP backbone were identified at the near surface region of the specimens by X-ray photoelectron spectroscopy (XPS). The insertion of such polar reactive functionalities was further confirmed by a substantial decrease in the water contact angle upon plasma treatment. Scanning ...
2009-03-01
Physics of electron beam therapy
International Nuclear Information System (INIS)
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
Oxide growth on aluminium alloys in the presence of ammonium fluoborate
Energy Technology Data Exchange (ETDEWEB)
The aim of this study as to determine the mechanisms involved in using ammonium fluoborate as a reducing atmosphere when preheating a high magnesium content aluminium alloy. Rutherford Backscattering (RBS) has been the major technique used in the analysis of samples, it revealed significant reduction in both the diffusion of magnesium to the surface and the calculated oxide thickness in the presence of NH{sub 4}BF{sub 4}. At temperatures above 500 deg C in air, SEM images revealed depressions and voids due to incipient melting at various stages, around the grain boundaries. Grain boundaries effectively acted as pipes aiding the diffusion of magnesium to the surface. These results have been verified through compositional analysis with both RBS and auger electron spectroscopy (AES). Results from NH{sub 4}BF{sub 4} atmosphere preheat conditions showed significant improvements. It was verified experimentally that above 500 deg C , AA5182 alloys undergo incipient ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also investigated. Only the Ni/GaAs reaction is ...
1987-03-01
Multilayered Nano-Microcomposite Ti-Al-N/TiN/Al_2O_3 Coatings. Their Structure and Properties
International Nuclear Information System (INIS)
This paper presents the first results on formation and study of structure and properties of micro- and nanocomposite combined coatings. By means of modeling the deposition processes (deposition conditions, current density-discharge, plasma composition and density, voltage) we formed the three-layer nanocomposite coatings of Ti-Al-N/Ti-N/Al_2O_3. The coating composition, structure and properties were studied using physical and nuclear-physical methods. The Rutherford proton and helium ion backscattering, scanning electron microscopy with microanalysis, grazing incidence X-ray diffraction, as well as nanohardness tests (hardness) were used. Measurements of wear resistance and corrosion resistance in NaCl, HCl and H_2SO_4 solutions were also performed. For testing mechanical properties such characteristics of layered structures as hardness H, elastic modulus E: H"3/E"2 etc. were measured. It is demonstrated that the formed three-layer nanocomposite coatings have ...
2011-07-01
Mode-locked YAG-Nd ring laser with unidirectional stimulated emission
Energy Technology Data Exchange (ETDEWEB)
The traveling-wave mode in ring lasers is achieved by two methods: by a reversing mirror, and by using an intracavity nonreciprocal device. This paper is devoted to realization of the traveling-wave mode in a mode-locked YAG-Nd ring laser by a method proposed by Tomov et al. This method uses two intracavity Q-switches. In mode-locked operation, pulses are generated that can be considered short compared with the period of modulation T = L/C (where L is the length of the perimeter of the cavity). Analysis shows that if the shift of the switching signals corresponds to the time of travel of a light pulse between Q-switches, the pulse in one direction will pass the Q-switches at instants of zero losses, while losses in the other direction will be maximized for a distance between Q-switches of L/4, and will be zero for a distance L/2. Experimental verification of the proposed method gave unidirectional lasing with an intensity ratio in the two directions of at least 600:1, the intensity of ...
1981-05-01
International Nuclear Information System (INIS)
A merged-beams electron-energy-loss technique is described, by which absolute cross sections can be measured for near-threshold electron-impact excitation of multipy charged ions. Results are reported here for absolute total electron-impact excitation cross sections for the O"5"+(2s#->#2p) transition from below threshold to 1.6 eV above threshold. The experimental data are in good agremeent with a seven-state close-coupling calculation throughout the energy range of the experiment. Results agree with calculations showing that more than 90% of the electrons causing excitation are ejected in the backward direction in the center-of-mass frame. This backscattering is shown in both quantum-mechanical and semiclassical calculations. Evidence is observed for high-lying metastable autoionizing states with a lifetime of approximately 0.9 #mu#s which are made to ionize by electron impact.
Ion beam mixing in Fe/Si and Ta/Si bilayers: Possible effects of ion charges
Energy Technology Data Exchange (ETDEWEB)
Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.
2003-05-01
Hybridization and Modification of the Ni/C{sub 60} Composites
Hybridization and thermal evolution of the Ni+C{sub 60} composites, deposited on Si(001) at room temperature, were studied using Scanning Electron Microscopy, {mu}-Raman spectroscopy and Rutherford Backscattering. As-deposited, the hybrid films exhibited a granular nano-structure with Ni nano-particles encapsulated in C{sub 60} polymerized rinds. The Ni and C (C{sub 60}) distributions in a top layer were found homogeneous with a stable Ni/C (C{sub 60}) ratio; in the larger depth the distributions were inhomogeneous and their ratio dramatically varied. At elevated temperatures, all structural parameters were changed. In the subsurface layer Ni- and C (C{sub 60})-rich zones were formed (due to the induced phase separation), C{sub 60}-molecules decayed and their fragments were transformed into amorphous carbon (a-C). The free volume distribution of the stressed hybrid matter was analyzed by the Hg marker that (in a form of vapors) in-diffused in to the samples. The ...
2009-03-10
Focused ion beam machined nanostructures depth profiled by macrochannelling ion beam analysis
International Nuclear Information System (INIS)
High aspect ratio sub-#mu#m periodic structures fabricated by focused ion beam (FIB) lithography have been characterised by Rutherford backscattering spectrometry (RBS) using the macrochannelling technique. The technique overcomes the limitations of complementary techniques such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), which can provide images with sub-#mu#m resolution of just the surface features and not of the deep sub-surface structures, without destructive cross sectioning of the sample. Here RBS macrochannelling with a 2 MeV He"+ ion beam is used to analyse a diffraction grating fabricated by FIB milling an array of 100 nm wide trenches in a 300 nm thick Ag film on a Si substrate. Using the surface structure imaged by SEM and AFM as a starting point, a numerical model for the RBS spectrum from the grating is fitted to the experimental spectrum as a function of the sub-surface structure. This process allows the width of the ...
2006-08-01
Electrical and structural properties of ion-implanted and post-annealed silicide films
Energy Technology Data Exchange (ETDEWEB)
The changes in the electrical and structural properties of metal-silicide films caused by ion implantation and subsequent thermal annealing have been investigated. Epitaxial silicide films such as those of CoSi/sub 2/, NiSi/sub 2/ and Pd/sub 2/Si grown on Si(111) substrates were implanted with Ar ions and annealed in a vacuum furnace at temperatures ranging from 200 to 800/sup 0/C. Rutherford backscattering and channeling techniques and the four-point probe method were used to measure the crystalline quality and the sheet resistance of the films, respectively. It was found that the sheet resistances of CoSi/sub 2/, NiSi/sub 2/ and Pd/sub 2/Si films were increased by factors of 70, 6, and 3, respectively, by implantation to a dose of 1 x 10/sup 16/ Ar-ions/cm/sup 2/, but that they were almost restored by subsequent annealing to the values before implantation. A phase transformation from Pd/sub 2/Si to PdSi was also observed in the high-temperature annealing of the ...
1982-05-01
Electrical and structural properties of ion-implanted and post-annealed silicide films
International Nuclear Information System (INIS)
The changes in the electrical and structural properties of metal-silicide films caused byion implantation and subsequent thermal annealing have been investigated. Epitaxial silicide films such as those of CoSi"2, NiSi"2 and Pd"2Si grown on Si(111) substrates were implanted with Ar ions and annealed in a vacuum furnace at temperatures ranging from 200 to 800_0C. Rutherford backscattering and channeling techniques and the four-point probe method were used to measure the crystalline quality and the sheet resistance of the films, respectively. It was found that the sheet resistances of CoSi"2, NiSi"2 and Pd"2Si films were increased by factors of 70, 6, and 3, respectively, by implantation to a dose of 1 x 10_1_6 Ar-ions/cm_2, but that they were almost restored by subsequent annealing to the values before implantation. A phase transformation from Pd"2Si to PdSi was also observed in the high-temperature annealing of the implanted Pd"2Si films. (author).
Die Backside FIB Preparation for Identification and Characterization of Metal Voids
Energy Technology Data Exchange (ETDEWEB)
Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view imaging of voids in lines and vias with ...
1999-07-28
Detection of the heavy Higgs boson at #gamma##gamma# colliders
International Nuclear Information System (INIS)
We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity of 10--20 fb"-"1.
Energy Technology Data Exchange (ETDEWEB)
To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs reactions studied are explained by considering ...
1987-09-01
Application of high rate magnetron sputtering to the fabrication of A-15 compounds
International Nuclear Information System (INIS)
High quality Nb_3Sn films have been fabricated using a recently developed magnetron sputtering process capable of deposition rates approaching 1 #mu#m/min at sputtering voltages less than 500 V and power levels of about 5 KW. Low sputtering voltages allow more complete thermalization at lower pressures of the material condensing on the substrate which can improve long range order. Transition temperatures of up to 18.3"0K, J/sub c/(0)'s of 15 x 10"6 A/cm"2 and Hc_2 as high as 240 k0e have been achieved in 1-3 #mu#m films deposited from a Nb_3Sn reacted powder target with substrate temperatures between 600 and 800"0C. The films exhibit smooth surfaces and, generally, a (200) preferred orientation. The growth of the film is columnar in nature. The sputtering parameters, substrate material and temperature will be related to film structure, T/sub c/ and J/sub c/(H,T) and the Nb/Sn ratio as determined by Rutherford backscattering.
Application of conventional laser technology to gamma-gamma colliders
International Nuclear Information System (INIS)
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns about the survivability of mirrors located ...
1994-03-28
Application of conventional laser technology to gamma-gamma colliders
Energy Technology Data Exchange (ETDEWEB)
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address concerns about the survivability of ...
1995-02-01
Application of conventional laser technology to gamma-gamma colliders
Energy Technology Data Exchange (ETDEWEB)
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...
1995-02-01
Analysis of semiconductor structures by nuclear and electrical techniques. Final technical report
This report summarizes the results obtained under a contract from 1974 to 1977, focusing on silicide formation of thin metal films on a Si substrate. The main thrust of the effort was directed at: (1) Development of the data base on thin-film silicide formation, and the investigation of the influence of the Si substrate on the silicide formation. When taken in context with results of other studies, the data obtained exhibit a clear pattern of behavior among the various metal films, but the detailed picture appears to be complex; (2) Development of marker experiments by ion-implanted Ar or Xe markers; (3) Clarification of the role played by oxygen contamination in silicide formation; (4) Stability of silicide layers; (5) Reaction of metal layers with SiO/sub 2/; (6) Electrical characteristics of Pd/sub 2/Si; and (7) A computer program was written to synthesize backscattering spectra for thin-film samples composed of successive layers of uniform thickness and ...
1978-06-01
A radionuclide analyzer of total sulfur in coal
International Nuclear Information System (INIS)
The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray fluorescence analysis but also ash in coal by the method of ...
1987-05-13
Vector Velocity Imaging Using Cross-Correlation and Virtual Sources
DEFF Research Database (Denmark)
Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, measurements have ...
2006-01-01
Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study
Energy Technology Data Exchange (ETDEWEB)
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...
2003-06-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
Energy Technology Data Exchange (ETDEWEB)
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...
1994-02-01
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...
2011-04-15
Energy Technology Data Exchange (ETDEWEB)
The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did not differ from that observed by 99mTc-sulfur colloid scan or ...
1988-12-01
Special phased array applications for pipeline girth weld inspections
Energy Technology Data Exchange (ETDEWEB)
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...
2004-07-01
Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience
International Nuclear Information System (INIS)
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two patients with larger ...
2010-08-01
Pioglitazone does not affect vascular or inflammatory responses after endotoxemia in humans.
PPARgamma agonists have been proposed to exert more than metabolic benefits, particularly by anti-inflammatory mechanisms. We hypothesized that pioglitazone might modulate inflammatory and vascular responses to lipopolysaccharide (LPS). In a placebo-controlled parallel-group study in 18 healthy male subjects, the E. coli endotoxin model of inflammation (20 IU/kg i. v.) was employed to test the effect of 60 mg pioglitazone over nine days on inflammatory cytokines. Macrovascular function and microvascular blood flow were assessed by brachial artery ultrasound and retinal blood flow parameters, respectively. Pioglitazone increased brachial artery diameter by 5.6% but had no effect on other outcome parameters under resting conditions. LPS increased cytokine levels to peak concentrations of 91.3+/-22.5 ng/ml (IL-6), 261.4+/-60.0 ng/ml (TNFalpha), and 524.5+/-15.3 ng/ml (VCAM-1). The endotoxin caused microvascular vasodilation and increased retinal white blood cell flux, ...
2008-05-21
Longitudinal changes in extended roles in radiography
Energy Technology Data Exchange (ETDEWEB)
Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...
2002-11-01
Energy Technology Data Exchange (ETDEWEB)
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen ...
2008-09-15
Image-guided pleural biopsy: diagnostic yield and complications
International Nuclear Information System (INIS)
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of ...
2006-08-01
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the correlation of mild renal pelvic dilatation (RPD) that is observed to be less than 10 mm on ultrasound (US) with urinary tract infection (UTI) and vesicoureteral reflux (VUR) in neonates. We reviewed 137 kidneys of 107 neonates who had RPD less than 10 mm on US. All the kidneys were divided into two groups: Group I (RPD <= 5.0 mm) and Group II (RPD > 5.0 mm), and we statistically analyzed the RPD change according to UTI and VUR. Seven neonates had VUR (5.1%), and there was no statistical significance between Group I (6 neonates, 5.6%) and Group II (1 neonate, 3.3%). Thirty seven cases (27%) had UTI and there was no statistical significance between Group I (30 cases, 28.0%) and Group II (7 cases, 23.3%). The RPD did not change in 81.8% of the cases, it increased in 4.4% of the cases and it decreased in 13.9% of the cases on follow up US. The incidence of VUR and UTI were not different according to the change of RPD. There were ...
2009-12-15
International Nuclear Information System (INIS)
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...
International Nuclear Information System (INIS)
For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace the focal and ...
2005-09-07
The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
International Nuclear Information System (INIS)
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more ...
2002-07-01
The efficiency of two thin-film diffusion barriers to be used in silicide/aluminum metallization schemes for silicon integrated circuits were evaluated. Control samples of Si/CoSi{sub 2}/Al and Si/Pd{sub 2}Si/Al, and test samples of Si/CoSi{sub 2}/Ta{sub 2}N/Al, Si/CoSi{sub 2}/W/Al and Si/Pd{sub 2}Si/Ta{sub 2}N/Al were used for sheet resistance, X-ray diffraction, Rutherford backscattering, and Auger-electron spectroscopic measurements. TEM studies were carried out on representative samples to examine the nature of the interfaces. Results from the analytical tests indicated that all three types of test samples are resistant to gross diffusion and intermixing of Co, Pd, Al and Si. They also showed that in the control samples, annealing causes interdiffusion of these species, necessitating the presence of a diffusion barrier. For test contacts, results demonstrated that although diffusion barriers may be successful in preventing metallurgical interdiffusion, they may ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Amorphization and a dual implant technique have been used to manipulate residual defects that persist following implantation and post-implant thermal treatments. Residual defects can often be attributed to ion-induced defect excesses. A defect is considered to be excess when it occurs in a localized region at a concentration greater than its complement. Sources of excess defects include spatially separated Frenkel pairs, excess interstitials resulting from the implanted atoms, and sputtering. Preamorphizing prior to dopant implantation has been proposed to eliminate dopant broadening due to ion channeling as well as dopant diffusion during subsequent annealing. However, transient-enhanced diffusion (TED) of implanted boron has been observed in pre-amorphized Si. The defects driving this enhanced boron diffusion are thought to be the extended interstitial-type defects that form below the amorphous-crystalline interface during implantation. A dual implantation process was applied in an ...
1999-06-01
International Nuclear Information System (INIS)
Amorphization and a dual implant technique have been used to manipulate residual defects that persist following implantation and post-implant thermal treatments. Residual defects can often be attributed to ion-induced defect excesses. A defect is considered to be excess when it occurs in a localized region at a concentration greater than its complement. Sources of excess defects include spatially separated Frenkel pairs, excess interstitials resulting from the implanted atoms, and sputtering. Preamorphizing prior to dopant implantation has been proposed to eliminate dopant broadening due to ion channeling as well as dopant diffusion during subsequent annealing. However, transient-enhanced diffusion (TED) of implanted boron has been observed in pre-amorphized Si. The defects driving this enhanced boron diffusion are thought to be the extended interstitial-type defects that form below the amorphous-crystalline interface during implantation. A dual implantation process was applied in an ...
1999-06-01
Energy Technology Data Exchange (ETDEWEB)
The growth of stoichiometric and non-stoichiometric silicon nitride films was studied experimentally on 100 mm silicon wafers by batch depositions from the dichlorosilane (SiH{sub 2}Cl{sub 2})-ammonia (NH{sub 3}) system in a hot-wall horizontal low pressure chemical vapor deposition (LPCVD) reactor. The growth kinetics were discussed in terms of the Langmuir adsorption isotherm. The kinetic parameters were determined by comparing the experimental data with a one-dimensional simulation model. The decomposition of NH{sub 3} at high temperatures was included in the simulation procedure. When the SiH{sub 2}Cl{sub 2}:NH{sub 3} ratios were greater than 1.5, a quantity higher than the thermodynamic critical values above which Si-rich nitride films begin to deposit, various SiN{sub x} films with x < 4/3 were obtained. The composition of the SiN{sub x} films was found to vary along the LPCVD reactor. The film stoichiometry was examined by Rutherford backscattering and ...
1992-06-15
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored which provided a high detection sensitivity ...
1983-12-15
For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons from the atoms contained in the crystal. Therefore, total power in the FEL laser is ...
2007-01-19
Pulse height response of Si surface barrier detectors to 5-70 MeV heavy ions
Energy Technology Data Exchange (ETDEWEB)
An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of the average energy for electron-hole pair creation with increasing particle stopping ...
1992-04-01
High quality La/sub 1.8/Sr/sub 0.2/CuO/sub 4/ and YBa/sub 2/Cu/sub 3/O/sub 7/ superconducting thin films, with zero resistance at 88 K, have been made by dual-ion-beam sputtering of metal and oxide targets at elevated temperatures. The films are about 1.0 ..mu..m thick and are single phase after annealing. The substrates investigated are Nd-YAP, MgO, SrF/sub 2/, Si, CaF/sub 2/, ZrO/sub 2/-9% Y/sub 2/O/sub 3/, BaF/sub 2/, Al/sub 2/O/sub 3/, and SrTiO/sub 3/. Characterization of the films was carried out using Rutherford backscattering spectroscopy, resistivity measurements, transmission electron microscopy, x-ray diffraction, and secondary ion mass spectroscopy. Substrate/film interaction was observed in every case. This generally involves diffusion of the substrate into the film, which is accompanied by, for example, the replacement of Ba by Sr in the YBa/sub 2/Cu/sub 2/O/sub 7/ structure, in the case of SrTiO/sub 3/ substrate. The best substrates were those that ...
1988-03-15
Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique
An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, C, and F were detected at the Pd/sub ...
1986-05-15
Energy Technology Data Exchange (ETDEWEB)
The compositions of passive films formed on Fe-17Fr-13Ni (at. %) and Fe-18.5Cr-14Ni-1.5Mo (100) single crystals have been determined and the structure of the alloy under the film has been investigated. The alloys were passivated in 0.05M H{sub 2}SO{sub 4} at 250 mV/SHE for 30 min. The oxygen content was measured by nuclear microanalysis using the {sup 16}O(d,p) {sup 17}O* reaction. The oxygen content in the passive film is similar for the two alloys and equal to (12{plus minus}2) 10{sup 15} O/cm{sup 2}. The cationic compositions of the passive films have been determined by {sup 4}He channeling at two incident beam energies: 0.8 and 2.0 MeV. For the two alloys studied, a total cation content of (5{plus minus}2)10{sup 15} at/cm{sup 2} is found in the passive films. The corresponding thickness is about 12 A. There is an excess of oxygen, which can be attributed to the presence of hydroxyls and sulfate. A strong chromium enrichment is found in the passive film formed on both alloys: ...
1990-01-01
International Nuclear Information System (INIS)
The compositions of passive films formed on Fe-17Fr-13Ni (at. %) and Fe-18.5Cr-14Ni-1.5Mo (100) single crystals have been determined and the structure of the alloy under the film has been investigated. The alloys were passivated in 0.05M H_2SO_4 at 250 mV/SHE for 30 min. The oxygen content was measured by nuclear microanalysis using the "1"6O(d,p) "1"7O* reaction. The oxygen content in the passive film is similar for the two alloys and equal to (12#+-#2) 10"1"5 O/cm"2. The cationic compositions of the passive films have been determined by "4He channeling at two incident beam energies: 0.8 and 2.0 MeV. For the two alloys studied, a total cation content of (5#+-#2)10"1"5 at/cm"2 is found in the passive films. The corresponding thickness is about 12 A. There is an excess of oxygen, which can be attributed to the presence of hydroxyls and sulfate. A strong chromium enrichment is found in the passive film formed on both alloys: chromium represents about 50% of the cations. There is no ...
1989-09-24
Higgs, SUSY and the standard model at {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property of the scalar sector can be explored in detail by making use of ...
2001-10-11
Higgs, SUSY and the standard model at #gamma##gamma# colliders
International Nuclear Information System (INIS)
In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by making use of linear polarization of the colliding photons, decay ...
2001-10-11
CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production
International Nuclear Information System (INIS)
We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton (photon) polarization and the final state lepton charge and study how well different combinations of these form factors can be ...
2003-09-01
Basics of Ion Scattering in Nanoscale Materials
Energetic ions interact with materials by collisions with the nuclei and electrons of the atoms that make up the material. In these collisions energy and momentum is transferred from the projectile particle which is a moving atom or ion, to the target particles (atomic nucleus or electron). Each collision leads to a slowing down of the moving projectile and also a deflection of the trajectory which gives rise to the term scattering which is often used synonymously to describe the energy transfer process. In this chapter, we introduce from an experimental viewpoint the underlying theory for interaction of ions for analysis and modification of nanometer scale materials. A more detailed theoretical overview of the topic can be found in the recent monographs by Sigmund. Detailed derivations of the formulae introduced will not be given here but can be found in standard texts that are indicated by references. The treatment here starts by considering an individual scattering event. The ...
2010-01-01
Aspects of two-photon physics at linear e"+e"- colliders
International Nuclear Information System (INIS)
We discuss various reactions at future e"+e"- and #gamma##gamma# colliders involving real (beamstrahlung or backscattered laser) or quasi-real (bremsstrahlung) photons in the initial state and hadrons in the final state. The production of two central jets with large transverse momentum p_T is described in some detail; we give distributions for the rapidity and p_T of the jets as well as the di-jet invariant mass, and discuss the relative importance of various initial state configurations and the uncertainties that arise from the at present rather poor knowledge of the parton content of the photon. We also present results for 'mono-jet' production where one jet goes down a beam pipe, for the production of charm, bottom and top quarks, and for single production of W and Z bosons. Where appropriate, the two-photon processes are compared with annihilation reactions leading to similar final states. We also argue that the behaviour of the total inelastic #gamma##gamma# ...
An FEL design for gamma-gamma colliders based on chirped pulse amplification techniques
International Nuclear Information System (INIS)
A next generation e"+-e"- linear collider in the TeV range can be converted into a #gamma#-#gamma# collider by converting it to e"--e"- operation and then generating #gamma#-rays via Compton backscattering with optical beams. This provides unique access to some areas of fundamental physics as well as highly desirable redundancy to the collisions. The required optical beam (with a wavelength of about 1 micron) must have very high peak power, (about 1 TW) as well as average power (about 10 kW). To achieve a 1 : 1 conversion from an electron to #gamma#-quantum, each micropulse must contain about one Joule and must be about one picosecond long, the micropulse peak power being about one Terawatt. To match the electron beam pulse structure, a macropulse consists of a sequence of about one hundred micropulses separated by about one nanosecond, and the macropulses am repeated at a rate of about 100 Hz. Thus, the time average power is about 10 kW propose and analyze a ...
1995-08-21
Airborne lidar experiments at the Savannah River Plant, June 1985
Energy Technology Data Exchange (ETDEWEB)
Results are presented from a series of studies conducted at the Department of Energy (DOE) Savannah River Plant (SRP) with the NASA Airborne Oceanographic Lidar (AOL). These studies included a topographic survey of a {approximately}1000 acre lake basin (presently designated L Lake) which had been excavated for use as a cooling pond for L Reactor; a study of the movement of discharged cooling water in Pond C and the warm arm of Par Pond using Rhodamine WT dye as a tag; initial baseline studies of the vegetation cover of the Steel Creek corridor (through which the outflow of L Lake is carried to the Savannah River); and a demonstration of potential forestry applications of the AOL. These investigations were conducted over a 3-day period in June 1985. The AOL is an advanced airborne laser system capable of making temporal or time history measurements of laser backscatter (bathymetry mode) or spectral measurements of laser induced fluorescence from waterborne ...
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...
2002-05-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...
2002-10-01
The role of interventional radiology in management of patients with end-stage renal disease
Energy Technology Data Exchange (ETDEWEB)
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The ...
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...
1998-03-01
Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility
Energy Technology Data Exchange (ETDEWEB)
NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with ...
2007-05-07
Solid state diffusion in metal silicides
International Nuclear Information System (INIS)
Radioactive "3"1Si was used as a marker to study metal silicide formation. Activity profiles in the silicides were measured by a combination of ion beam sputtering, radioactivity counting and Rutherford backscattering of charged nuclear particles. It was found that the metal is the diffusing species during Co_2Si, Pt_2Si, NiSi and PtSi formation, while silicon diffuses during CrSi_2, TiSi_2 and ZrSi_2 formation. Silicon was also found to be the diffusing species during second phase formation of CoSi from Co_2Si. However, in this case it was established that the silicon diffuses by a grain boundary and/or interstitial mechanism. Both the metal and silicon diffuse during Ni_2Si and Pd_2Si formation. In an attempt to interpret complex radioactivity profiles a computer program, simulating various diffusion mechanisms during both first and second phase silicide formation, was written. A numerical approach was used whereby silicide growth occurs in small increments and ...
Energy Technology Data Exchange (ETDEWEB)
The motivation of this work is to develop high reflectance normal-incidence multilayer mirrors in the 8-12 nm wavelength region for applications in astronomy and extreme ultraviolet lithography. To achieve this goal, Mo/Sr and Mo/Y multilayers were studied. These multilayers were deposited with a UHV magnetron sputtering system and their reflectances were measured with synchrotron radiation. High normal-incidence reflectances of 23% at 8.8 nm, 40.8% at 9.4 nm, and 48.3% at 10.5 nm were achieved. However, the reflectance of Mo/Sr multilayers decreased rapidly after exposure to air. Attempts to use thin layers of carbon to passivate the surface of Mo/Sr multilayers were unsuccessful. Experimental results on the refractive index {tilde n} = 1-{delta} + i{beta} of yttrium and molybdenum in the 50-1300 eV energy region are reported in this work. This is the first time ever that values on the refractive index of yttrium are measured in this energy range. The absorption part {beta} was ...
2002-09-01
A kinetic and mechanistic study of the oxidation of silicon- and thin metal silicide layers
International Nuclear Information System (INIS)
The formation of thin SiO_2 layers on silicon and metal silicides was studied by phase- and thickness measurements with Rutherford back-scattering of 2 MeV alfa particles. Thermal oxidation was done in steam and dry oxygen at temperatures between 750 degrees Celsius and 1 100 degrees Celsius, while SiO_2 formation at room temperature was carried out by anodic oxidation. The study of silicon oxidation was done on Si<100>, Si<111> and amorphous silicon substrates. Thermal oxidation of CoSi_2, CrSi_2, NiSi_2, PtSi and TiSi_2 was investigated. The oxidation rates of the silicides were found to be much higher than for silicon. The oxidation process is also diffusion-limited with a higher oxidation rate for steam as compared to dry oxygen. The silicide layers were found to stay intact during thermal oxidation. A certain amount of structural and chemical instability did appear. Chemical instabiliy was shown by metal oxidation which led to metal atoms being ...
Energy Technology Data Exchange (ETDEWEB)
To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical evaluation by ultrasound and MRI, preferable location of treatable ...
2003-08-01
Energy Technology Data Exchange (ETDEWEB)
TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, ...
2003-08-01
Energy Technology Data Exchange (ETDEWEB)
Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., patient's (ideal) body weight and skin fold measures. A statistically significant correlation was found ...
1999-12-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
