WorldWideScience
1

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the ...

2006-02-24

3

Application of dose factors for decay chains  

International Nuclear Information System (INIS)

... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor

4

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

5

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

6

Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note  

Energy Technology Data Exchange (ETDEWEB)

The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.

1986-01-01

7

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

8

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

9

Fixed time and fixed point observation of environmental radioactivities in Tokyo  

Energy Technology Data Exchange (ETDEWEB)

A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon concentration ...

1997-03-01

10

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This ...

1983-06-01

11

ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies  

Energy Technology Data Exchange (ETDEWEB)

Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular ...

2010-11-30

12

Population exposure to external natural radiation background in the United States  

Energy Technology Data Exchange (ETDEWEB)

This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.

1981-04-01

13

Adalimumab sustains steroid-free remission after 3-years of therapy for Crohn-s disease  

British Library Electronic Table of Contents (United Kingdom)

Summary Background- Treatments that achieve sustainable steroid-free clinical remission in Crohn-s disease are needed; however, long-term steroid-sparing efficacy data are limited. Aim- To evaluate steroid-sparing efficacy and the impact of steroid discontinuation on adverse events during treatment of Crohn's disease with adalimumab in the phase III randomised, double-blind 1-year CHARM trial and for an additional 2-years in its open-label extension ADHERE. Methods- Steroid-free remission and response and steroid-sparing (-50% steroid dose reduction) remission rates were evaluated over 3-years in patients who were taking corticosteroids at CHARM baseline. Results- Of 778 patients randomised in CHARM (including those who did not achieve clinical response to open-label induction therapy), 31...

2011-01-01

14

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

15

A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers  

UK PubMed Central (United Kingdom)

Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available

2007-04-01

16

Medical consequences of radiation accidents  

International Nuclear Information System (INIS)

Since 1945, more than 1.8 x 10"2"1 Bq of artificial radionuclides have been released into the atmosphere. Approximately 2.04 x 10"1"8B, i.e. approx. 0.11%, are the result of accidents at nuclear industrial facilities. This percentage is causing increased interest among researchers. This is due to the fact that in the wake of accidental release radionuclides become distributed unevenly across the Earth's surface, and the associated exposures, fluctuating from background level to several grays, an induce both stochastic and deterministic effects in the irradiated population. A comparative analysis of the medical consequences of the twentieth century's most serious nuclear events, namely the authorized dumping of high level radioactive waste into the river Techa in 1950, the explosion of a storage tank containing long lived radioactive waste in the Southern Urals in 1957, the fire at Sellafield in 1957 and the accident at the Chernobyl nuclear power plant in 1986, has ...

1995-10-01

17

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

18

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

19

Multiple concentric annuli for characterizing spatially nonuniform backgrounds  

CERN Document Server

A method is presented for estimating the background at a given location on a sky map by interpolating the estimated background from a set of concentric annuli which surround this location. If the background is nonuniform but smoothly varying, this method provides a more accurate (though less precise) estimate than can be obtained with a single annulus. Several applications of multi-annulus background estimation are discussed, including direct testing for point sources in the presence of a nonuniform background, the generation of "surrogate maps" for characterizing false alarm rates, and precise testing of the null hypothesis that the background is uniform.

1999-01-01

20

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of {sup 40}K, {sup 238}U and {sup 232}Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of {sup 40}K, {sup 238}U and {sup 232}Th in local prepared diets ranged between 60 and 494 Bq kg{sup -1}, between BDL and 48 Bq kg{sup -1} and between BDL and 17 Bq kg{sup -1}, respectively. The internal effective dose to individuals from ...

2007-04-15

21

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

International Nuclear Information System (INIS)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of "4"0K, "2"3"8U and "2"3"2Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of "4"0K, "2"3"8U and "2"3"2Th in local prepared diets ranged between 60 and 494 Bq kg"-"1, between BDL and 48 Bq kg"-"1 and between BDL and 17 Bq kg"-"1, respectively. The internal effective dose to individuals from the consumption of the food ...

2007-04-01

22

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated ...

2003-07-01

23

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed ...

2007-08-01

24

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

25
26

Methodology used to compute maximum potential doses from ingestion of edible plants and wildlife found on the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are ...

1990-10-01

27

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and ...

2005-11-23

28

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

29

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

30

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 ...

2005-01-01

31

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as ...

2005-01-01

32
33

Method of risk estimates for genetic, leukemogenic and carcinogenic effects from medical and occupational exposures  

International Nuclear Information System (INIS)

For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...

1980-01-01

34

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient ...

1991-06-01

35

Isochron measurements of naturally irradiated K-feldspar grains  

International Nuclear Information System (INIS)

The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function ...

2007-09-01

36

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...

2002-12-01

37

Hyperfractionated radiation therapy for incompletely resected supratentorial low-grade glioma. A phase II study  

International Nuclear Information System (INIS)

Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year ...

1998-10-01

38

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, ...

2006-11-13

39

Reduced "9"9"mTc labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution  

International Nuclear Information System (INIS)

The influence of reconstituting a murine monoclonal IgG_1 antibody kit with pertechnetate Tc99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The "9"9"mTc-labelled antibody used is directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined ...

40

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...

1991-01-01

41

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped ...

2006-02-07

42

Experimental and theoretical studies of nuclear generation of ozone from oxygen and oxygen--sulfur hexafluoride mixtures  

International Nuclear Information System (INIS)

A series of experimental measurements of the yield of O_3 in nuclear-induced O_2 and O_2-SF_6 discharges are reported. The discharges were created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction. Continuous irradiation at dose rates of 10"1"5--10"1"7 eV cm"-"3 s"-"1 and pulsed irradiation (--10 ms FWHM) at a peak dose rate of --10"2"0 eV cm"-"3 s"-"1 were conducted. At the lower dose rates, the addition of SF_6 generally increased the ozone yield due to the slowing of ozone destruction by negative oxygen and ozone ions. In contrast, at the high dose rates, the ozone concentration decreased due to SF_6 suppression of atomic oxygen formation by ion--ion recombination. A numerical model was developed and tested against experimental conditions. This model indicates that the steady-state ozone ...

43

Uncorrelated Randomness of the Heart Rate Is Associated with Sepsis in Sick Premature Infants  

UK PubMed Central (United Kingdom)

BackgroundLate-onset sepsis in the premature infant is frequently revealed by severe, unusual and recurrent bradycardias. In view of the high morbidity and mortality...Full Text Available

2009-03-01

44

The Allometry of Host-Pathogen Interactions  

UK PubMed Central (United Kingdom)

BackgroundUnderstanding the mechanisms that control rates of disease progression in humans and other species is an important area of research relevant to epidemiology and to translating...Full Text Available

45

Prognostic Indicators of Surgery for Esophageal Cancer: A 5 Year Experience  

UK PubMed Central (United Kingdom)

Background/Aim:To assess the prognostic indicators preoperatively presenting and influencing the mortality rate following esophagectomy for esophageal cancer.Full Text Available

2010-10-01

46

Compressing DNA sequence databases with coil  

UK PubMed Central (United Kingdom)

BackgroundPublicly available DNA sequence databases such as GenBank are large, and are growing at an exponential rate. The sheer volume of data being dealt with presents serious...Full Text Available

47

The effectiveness of reducing the daily dose of finasteride in men with benign prostatic hyperplasia  

UK PubMed Central (United Kingdom)

BackgroundFinasteride, a 5 alpha reductase inhibitor, is an established treatment for benign prostatic hyperplasia. The recommended dosage is 5 mg a day, however case reports have...Full Text Available

48

Serum Concentrations of Antibodies Against Vaccine Toxoids in Children Exposed Perinatally to Immunotoxicants  

UK PubMed Central (United Kingdom)

BackgroundPolychlorinated biphenyls (PCBs) may cause immunotoxic effects, but the detailed dose–response relationship and possible vulnerable time windows of exposure are...Full Text Available

2010-10-01

49

Low-Level Exposure to Multiple Chemicals: Reason for Human Health Concerns?  

UK PubMed Central (United Kingdom)

BackgroundA key question in the risk assessment of exposures to multiple chemicals is whether mixture effects may occur when chemicals are combined at low doses which individually...Full Text Available

2007-12-01

50

Life-Span Exposure to Low Doses of Aspartame Beginning during Prenatal Life Increases Cancer Effects in Rats  

UK PubMed Central (United Kingdom)

BackgroundIn a previous study conducted at the Cesare Maltoni Cancer Research Center of the European Ramazzini Foundation (CMCRC/ERF), we demonstrated for the first time that aspartame...Full Text Available

2007-09-01

51

Lack of impact of intravenous lidocaine on analgesia, functional recovery, and nociceptive pain threshold after total hip arthroplasty  

UK PubMed Central (United Kingdom)

BackgroundThe analgesic effect of perioperative low doses intravenous lidocaine has been demonstrated after abdominal surgery. This study aimed to evaluate whether...Full Text Available

2008-07-01

52

General lack of global dosage compensation in ZZ/ZW systems? Broadening the perspective with RNA-seq  

UK PubMed Central (United Kingdom)

BackgroundSpecies with heteromorphic sex chromosomes face the challenge of large-scale imbalance in gene dose. Microarray-based studies in several independent male heterogametic...Full Text Available

53

Dosing Recommendations for Continuous Venovenous Hemodiafiltration with AN69 Filter Membranes and Prismaflex Dialyzers  

UK PubMed Central (United Kingdom)

Background:Continuous renal replacement therapy is used to manage fluid and solute imbalances in critically ill patients but may affect the clearance of concurrently administered...Full Text Available

2009-11-01

54

Considerable Variability in Platelet Activity among Patients with Coronary Artery Disease in Response to an Increased Maintenance Dose of Clopidogrel  

UK PubMed Central (United Kingdom)

BackgroundVariable platelet response to clopidogrel has been widely observed. Studies have shown that the mean aggregation response to clopidogrel can be changed...Full Text Available

2009-05-01

55

Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available

56

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

57

Unique health care utilization patterns in a homeless population in Ghent  

UK PubMed Central (United Kingdom)

BackgroundExisting studies concerning the health care use of homeless people describe higher utilisation rates for hospital-based care and emergency care, and lower rates for primary...Full Text Available

58

Measuring IBS patient reported outcomes with an abdominal pain numeric rating scale: results from the proof cohort  

UK PubMed Central (United Kingdom)

BackgroundControversy exists about how to effectively measure patient reported outcomes in IBS clinical trials. Pain numeric rating scales (NRS) are widely used in...Full Text Available

2009-12-01

59

Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture  

UK PubMed Central (United Kingdom)

BackgroundHip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral...Full Text Available

60

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

61

Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization  

CERN Document Server

Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given ...

2005-01-01

62

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...

1976-01-01

63

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the ...

2005-11-23

64

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

65

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

66

The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type  

Energy Technology Data Exchange (ETDEWEB)

There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation was done on the relationship between ...

1999-09-01

67

Irradiation with and without razoxane in the treatment of incompletely resected or inoperable recurrent rectal cancer. Results of a small randomized multicenter study  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, ...

2007-07-15

68

Cytogenetic effects of protracted gamma exposures from conception of male mice  

Energy Technology Data Exchange (ETDEWEB)

In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbed doses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation ...

1982-01-01

69

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV ...

2009-09-01

70

C-14 release and transport from a nuclear waste repository in an unsaturated medium  

Energy Technology Data Exchange (ETDEWEB)

The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...

1990-06-01

71

High-dose neutron-irradiation effects in fcc metals at 4.6 K  

International Nuclear Information System (INIS)

The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as ...

1977-12-01

72

LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay  

British Library Electronic Table of Contents (United Kingdom)

LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.

2011-01-01

73

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...

2006-07-01

74

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the ...

2007-03-15

75

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared ...

2003-01-01

76

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with ...

1984-10-01

77

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with ...

1984-10-01

78

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population ...

1984-01-01

79

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can ...

1996-12-31

80

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can ...

1996-11-10

81

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: Proposal for an adapted formalism  

International Nuclear Information System (INIS)

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.

2001-04-01

82

Molecular targeted treatment and radiation therapy for rectal cancer  

Energy Technology Data Exchange (ETDEWEB)

Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low ...

2009-06-15

83

Diagnostic imaging of Thorotrast associated cholangiocarcinoma and mixed hepatocellular and cholangiocellular carcinoma  

International Nuclear Information System (INIS)

Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to detect againist such an ...

84

Radioiodine dosimetry and prediction of consequences of thyroid exposure of the Russian population following the Chernobyl accident  

International Nuclear Information System (INIS)

In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in ...

85

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue  

International Nuclear Information System (INIS)

Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...

2003-10-01

86

Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ ...

2003-01-01

87

AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source  

International Nuclear Information System (INIS)

We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be used for treatment ...

2004-04-01

88

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

89

Multicellular level dosimetry and low dose rate effects  

International Nuclear Information System (INIS)

Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.

1989-09-21

90

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

91

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

93

Chemical carcinogenesis: too many rodent carcinogens.  

UK PubMed Central (United Kingdom)

The administration of chemicals at the maximum tolerated dose (MTD) in standard animal cancer tests is postulated to increase cell division (mitogenesis), which in turn increases rates of mutagenesis...Full Text Available

1990-10-01

94

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high ...

1976-01-01

95

The characterization of electron beam and its importance  

International Nuclear Information System (INIS)

The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)

2003-07-22

96

Comparison of the genetic effects of equimolar doses of ENU and MNU: While the chemicals differ dramatically in their mutagenicity in stem-cell spermatogonia, both elicit very high mutation rates in differentiating spermatogonia  

UK PubMed Central (United Kingdom)

Mutagenic, reproductive, and toxicity effects of two closely related chemicals, ethylnitrosourea (ENU) and methylnitrosourea (MNU), were compared at equimolar and near-equimolar doses in the...Full Text Available

2007-03-01

97

Commentary  

International Nuclear Information System (INIS)

1. It is not possible to give a threshold value for the dose - nor for genetic neither for somatic late effects. 2. The linear dose-effect exprapolation is not conservative in the sense of 'fying on the safe side'. 3. There has been found no relative reduction of the effects at chronic radiation exposure in man. 4 The numbers given by authorities and utilities for damage rates per rem received, that are called upper limits, are by far too low. (orig./HP).

1980-02-01

98

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix-Whole Pelvis External Irradiation end High-Dose-Rate Interactively Irradiation  

International Nuclear Information System (INIS)

Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still 44% of patient will develop recurrent cancer This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen which is 500-1000 cGy higher than other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was 46%, but only 1 ...

1989-06-01

99

Monte Carlo Uncertainty Analyses of Pulsed Activation in the National Ignition Facility Gunite Shielding  

International Nuclear Information System (INIS)

The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.

2003-05-01

100

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the ...

1999-02-01

101

Somatic effects in nuclear medicine and radiology  

International Nuclear Information System (INIS)

Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.

1999-01-01

102

Influence of dose calculation algorithms on isotoxic dose-escalation of non-small cell lung cancer radiotherapy  

International Nuclear Information System (INIS)

Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same prescription ...

2010-12-01

103

Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada  

Energy Technology Data Exchange (ETDEWEB)

Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from ...

1994-06-01

104

Trade-offs Between Seedling Growth and Survival in Deciduous Broadleaved Trees in a Temperate Forest  

UK PubMed Central (United Kingdom)

Background and AimsIn spatially heterogeneous environments, a trade-off between seedling survival and relative growth rate may promote the coexistence of plant species. In temperate...Full Text Available

2007-03-01

105

The relationship between the rate of melatonin excretion and sleep consolidation for locomotive engineers in natural sleep settings  

UK PubMed Central (United Kingdom)

BackgroundThe aim of the study was to examine the role that melatonin production plays in the regulation of sleep consolidation in a population of shiftworkers working and sleeping...Full Text Available

106

The relationship between change in subjective outcome and change in disease: a potential paradox  

UK PubMed Central (United Kingdom)

BackgroundResponse shift theory suggests that improvements in health lead patients to change their internal standards and re-assess former health states as worse than initially rated...Full Text Available

2010-09-01

107

The influence of histological diagnosis on the postoperative complication rate following trans-urethral resection of prostate (TURP).  

UK PubMed Central (United Kingdom)

BACKGROUND: A number of studies have shown that the early mortality following TURP is higher for patients with prostate cancer than those with benign disease. This study examines the effect of the histological...Full Text Available

2002-11-01

108

The erratic mitochondrial clock: variations of mutation rate, not population size, affect mtDNA diversity across birds and mammals  

UK PubMed Central (United Kingdom)

BackgroundDuring the last ten years, major advances have been made in characterizing and understanding the evolution of mitochondrial DNA, the most popular marker of molecular biodiversity....Full Text Available

109

The CORONIS Trial. International study of caesarean section surgical techniques: a randomised fractional, factorial trial  

UK PubMed Central (United Kingdom)

BackgroundCaesarean section is one of the most commonly performed operations on women throughout the world. Rates have increased in recent years – about 20–25% in...Full Text Available

110

Temporal trends in hepatitis B and C infection in family blood donors from interior Sindh, Pakistan  

UK PubMed Central (United Kingdom)

BackgroundHepatitis B (HBV) and C (HCV) infections are a serious global and national public health problem. Earlier studies have reported increasing rates of hepatitis infection...Full Text Available

111

Socio-demographic and health-related factors associated with cognitive impairment in the elderly in Taiwan  

UK PubMed Central (United Kingdom)

BackgroundCognitive impairment is an age-related condition as the rate of cognitive decline rapidly increases with aging. It is especially important to better understand factors...Full Text Available

112

Rapid Onset of Maternal Vocal Recognition in a Colonially Breeding Mammal, the Australian Sea Lion  

UK PubMed Central (United Kingdom)

BackgroundIn many gregarious mammals, mothers and offspring have developed the abilities to recognise each other using acoustic signals. Such capacity may develop at different rates...Full Text Available

113

Post traumatic stress symptoms and heart rate variability in Bihar flood survivors following yoga: a randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundAn earlier study showed that a week of yoga practice was useful in stress management after a natural calamity. Due to heavy rain and a rift on the banks of the Kosi river,...Full Text Available

114

Population-based prevention of influenza in Dutch general practice.  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the effectiveness of influenza vaccination in high-risk groups has been proven, vaccine coverage continues to be less than 50% in The Netherlands. To improve vaccination rates,...Full Text Available

1997-06-01

115

Phylogenetic inference in Rafflesiales: the influence of rate heterogeneity and horizontal gene transfer  

UK PubMed Central (United Kingdom)

BackgroundThe phylogenetic relationships among the holoparasites of Rafflesiales have remained enigmatic for over a century. Recent molecular phylogenetic studies using the mitochondrial...Full Text Available

116

Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access  

UK PubMed Central (United Kingdom)

BackgroundThe survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably...Full Text Available

2010-10-01

117

Outcomes Associated with Race in Males with Nondialysis-Dependent Chronic Kidney Disease  

UK PubMed Central (United Kingdom)

Background and objectives: Blacks are over-represented among dialysis patients, but they have better survival rates than whites. It is unclear if the over-representation of blacks on dialysis is due...Full Text Available

2009-05-01

118

Long-Range Correlations in Rectal Temperature Fluctuations of Healthy Infants during Maturation  

UK PubMed Central (United Kingdom)

BackgroundControl of breathing, heart rate, and body temperature are interdependent in infants, where instabilities in thermoregulation can contribute to apneas or even life-threatening...Full Text Available

119

Life after Breast Cancer: Dealing with Lymphoedema  

UK PubMed Central (United Kingdom)

Background:In recent years, breast cancer (BC) mortality rates have declined, reflecting advances in early detection. Prevention and management of treatment sequelae that could impair...Full Text Available

120

Interface of culture, insecurity and HIV and AIDS: Lessons from displaced communities in Pader District, Northern Uganda  

UK PubMed Central (United Kingdom)

BackgroundNorthern Uganda unlike other rural regions has registered high HIV prevalence rates comparable to those of urbanized Kampala and the central region. This could be due to...Full Text Available

121

Injuries at a Canadian National Taekwondo Championships: a prospective study  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of this prospective study was to assess the injury rates in male and female adult Canadian Taekwondo athletes relative to total number of injuries, type and...Full Text Available

122

Impact of Proteinuria and Glomerular Filtration Rate on Risk of Thromboembolism in Atrial Fibrillation: the ATRIA Study  

UK PubMed Central (United Kingdom)

BackgroundAtrial fibrillation (AF) substantially increases the risk of ischemic stroke but this risk varies among individual patients with AF. Existing risk stratification...Full Text Available

2009-03-17

123

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

124

Expression and prognostic significance of cox-2 and p-53 in hodgkin lymphomas: a retrospective study  

UK PubMed Central (United Kingdom)

BackgroundCyclooxygenase (cox) is the rate-limiting enzyme, which catalyzes the conversion of arachidonic acid into prostaglandins and contributes to the inflammatory process. Cyclooxygenase-2...Full Text Available

125

Evidence from ammonoids and conodonts for multiple Early Triassic mass extinctions  

UK PubMed Central (United Kingdom)

Ammonoids and conodonts, being characterized by exceptionally high background rates of origination and extinction, were vulnerable to global environmental crises, which characteristically intensified...Full Text Available

2009-09-08

126

Efficacy and cost-effectiveness of nutritional intervention in elderly after hip fracture: design of a randomized controlled trial  

UK PubMed Central (United Kingdom)

BackgroundHip fracture patients often have an impaired nutritional status at the time of fracture, which can result in a higher complication rate, prolonged rehabilitation time and...Full Text Available

127

Djinn Lite: a tool for customised gene transcript modelling, annotation-data enrichment and exploration  

UK PubMed Central (United Kingdom)

BackgroundThere is an ever increasing rate of data made available on genetic variation, transcriptomes and proteomes. Similarly, a growing variety of bioinformatic programs are becoming...Full Text Available

128

Divorce, divorce rates, and professional care seeking for mental health problems in Europe: a cross-sectional population-based study  

UK PubMed Central (United Kingdom)

BackgroundLittle is known about differences in professional care seeking based on marital status. The few existing studies show more professional care seeking among the divorced...Full Text Available

129

Council tax valuation band predicts breast feeding and socio-economic status in the ALSPAC study population  

UK PubMed Central (United Kingdom)

BackgroundBreast-feeding rates in the UK are known to vary by maternal socio-economic status but the latter function is imperfectly defined. We test if CTVB (Council Tax Valuation...Full Text Available

130

Comparison of deferral rates using a computerized versus written blood donor questionnaire: a randomized, cross-over study [ISRCTN84429599  

UK PubMed Central (United Kingdom)

BackgroundSelf-administered computer-assisted blood donor screening strategies may elicit more accurate responses and improve the screening process.MethodsRandomized...Full Text Available

131

Chiropteran types I and II interferon genes inferred from genome sequencing traces by a statistical gene-family assembler  

UK PubMed Central (United Kingdom)

BackgroundThe rate of emergence of human pathogens is steadily increasing; most of these novel agents originate in wildlife. Bats, remarkably, are the natural reservoirs of many...Full Text Available

132

Association of B-Type Natriuretic Peptide Levels With Estimated Glomerular Filtration Rate and Congestive Heart Failure  

UK PubMed Central (United Kingdom)

Background: The causes of elevated B-Type natriuretic peptide (BNP) levels are multifactorial. Renal dysfunction has been shown to affect BNP levels in some studies and...Full Text Available

2010-03-01

133

Association between intratumoral lymphatic microvessel density (LMVD) and clinicopathologic features in endometrial cancer: a retrospective cohort study  

UK PubMed Central (United Kingdom)

BackgroundLymph node metastasis in endometrial cancer significantly decreases survival rate. Few data on the influence of intratumoral lymphatic microvessel density (LMVD) on survival...Full Text Available

134

An argument for the conservative management of small traumatic pneumathoraces in populations with high prevalence of HIV and tuberculosis: an evidence-based review of the literature  

UK PubMed Central (United Kingdom)

BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available

135

An Energy-Saving Development Initiative Increases Birth Rate and Childhood Malnutrition in Rural Ethiopia  

UK PubMed Central (United Kingdom)

BackgroundEvolutionary life history theory predicts that, in the absence of contraception, any enhancement of maternal condition can increase human fertility. Energetic...Full Text Available

2006-04-01

136

A proteomic study of cMyc improvement of CHO culture  

UK PubMed Central (United Kingdom)

BackgroundThe biopharmaceutical industry requires cell lines to have an optimal proliferation rate and a high integral viable cell number resulting in a maximum volumetric recombinant...Full Text Available

137

A participatory parent-focused intervention promoting physical activity in preschools: design of a cluster-randomized trial  

UK PubMed Central (United Kingdom)

BackgroundWith rates of childhood obesity increasing, physical activity (PA) promotion especially in young children has assumed greater importance. Given the limited effectiveness...Full Text Available

138

Expansion Rate Measurements at Moderate Pressure of Nonneutral Electron Plasmas in the Electron Diffusion Gauge (EDG) Experiment  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the expansion rate of pure-electron plasmas have been performed on the Electron Diffusion Gauge (EDG) device at background helium gas pressures in the 5 x 10(superscript -8) Torr to 1 x 10(superscript -5) Torr range, where plasma expansion due to electron-neutral collisions dominates over plasma expansion due to trap asymmetries. It is found that the expansion rate, defined as the time rate of change of the particles' mean-square radius, scales approximately linearly with pressure and inversely as the square of the magnetic field strength in this regime, in agreement with classical predictions.

2001-05-18

139

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

140

Radiation oxidation of phenol in petrochemical waste water. II  

International Nuclear Information System (INIS)

The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).

1981-01-01

141

Preliminary activation calculations for the PDX tokamak  

Energy Technology Data Exchange (ETDEWEB)

Activation dose rates have been computed for the Poloidal Divertor Experiment Tokamak at the Princeton Plasma Physics Laboratory. Dose rates were computed in one-dimensional (cylindrical) geometry using the ANISN S/sub n/ transport theory code and the DKR radioactivity code. The EPR (DLC37F) 121-group coupled neutron-gamma cross section library was used with ANISN. For DKR, the 46-group neutron library of DCDLIB was employed. Dose rates were calculated for 1 minute, 1 hour, 6 hours, 24 hours, 1 week, and 1 month following a single pulse yielding 10/sup 15/ neutrons and for 2 hypothetical pulsing sequences. First, it was assumed that 10 pulses were conducted each day (1 hour apart) for 5 days. Second, it was assumed that 100 pulses were conducted each day (6 minutes apart) for 5 days. It was found that /sup 56/Mn and /sup 64/Cu are the main contributors to the ...

1980-10-01

142

A 24-week, multicentre, open evaluation of the clinical effectiveness of the rivastigmine patch in patients with probable Alzheimer-s disease  

British Library Electronic Table of Contents (United Kingdom)

Summary Background:- Cholinesterase inhibitors form the mainstay of treatment for persons with mild-to-moderate Alzheimer-s disease (AD). The rivastigmine patch may increase compliance and the proportion of patients maintaining an efficacious dose compared with oral cholinesterase inhibitors. Objective:- To investigate the proportion of patients who reached and maintained the target rivastigmine patch dose compared with the target rivastigmine capsule dose reported in clinical trials. Methods:- This was a multicentre, 24-week, open-label study in persons with probable AD and a Mini-Mental State Examination (MMSE) score of --10 and --26. The primary outcome was the proportion of patients (ITT population) treated with 9.5-mg/24-h rivastigmine patch for at least 8-weeks at week 24. Secondary ...

2011-01-01

143

Tissue equivalent proportional counter real time neutron monitor  

International Nuclear Information System (INIS)

The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved ...

1978-10-25

144

Radiation grafting processes and properties of leathers modified with butyl acrylate  

International Nuclear Information System (INIS)

Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished ...

1982-01-01

145

Luminescence geochronology and evaluation of the environmental dose rate for the Neanderthal deposits at Vindija Cave (Northern Croatia)  

International Nuclear Information System (INIS)

Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. ...

2008-04-13

146

TRANSMUTATIONS IN SiC IRRADIATED IN ARIES-IV FIRST WALL  

Science.gov (United States)

The change in concentrations of elements due to transmutations resulting from neutron irradiation in the first wall of the ARIES-IV conceptual fusion energy device were determined as a function of neutron dose. SiC burns out at a rate of about 0.5% per effective full power year. The largest impurity concentration is that of He, but several other elements burn in at rates of hundreds of appm/efpy.

2001-04-01

147

Radon and radon daughter evaluation in a natural radioactivity survey indoors  

Energy Technology Data Exchange (ETDEWEB)

An indoor survey in order to estimate the population exposure in five towns of an Italian Region is presented. A particular methodology for the campaign was planned and is being applied. Gamma spectrometry of building materials, exposure rate measurements indoors and outdoors and radon concentration measurements indoors were taken with different techniques. A correlation was found between mean gamma exposure rate and mean radon concentration in the houses investigated. An evaluation of mean effective dose equivalents for the inhabitants of the five towns is reported.

1985-10-01

148

Updated estimates of the proportion of childhood leukaemia incidence in Great Britain that may be caused by natural background ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous ...

2009-12-01

149

In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation  

UK PubMed Central (United Kingdom)

BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available

150

Achieving cholesterol targets by individualizing starting doses of statin according to baseline low-density lipoprotein cholesterol and coronary artery disease risk category: The CANadians Achieve Cholesterol Targets Fast with Atorvastatin Stratified Titration (CanACTFAST) study  

UK PubMed Central (United Kingdom)

BACKGROUND:Despite an increasing body of evidence on the benefit of lowering elevated levels of low-density lipoprotein cholesterol (LDL-C), there is still considerable concern that...Full Text Available

2010-02-01

151

Is the association between optimistic cardiovascular risk perceptions and lower rates of cardiovascular disease mortality explained by biomarkers of systemic inflammation or endothelial function? A case-cohort study  

UK PubMed Central (United Kingdom)

BackgroundMore optimistic perceptions of cardiovascular disease risk are associated with substantively lower rates of cardiovascular death among men. It remains unknown whether this...Full Text Available

152

Radiological dose assessment for the decontaminated concrete removed from 183-H solar evaporation basins at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is ...

1997-01-01

153

Assessing radiologic risk for population due to human activities  

International Nuclear Information System (INIS)

The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...

2002-09-06

154

Land And Water Use Characteristics And Human Health Input Parameters For Use In Environmental Dosimetry And Risk Assessments At The Savannah River Site  

International Nuclear Information System (INIS)

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be ...

155

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

International Nuclear Information System (INIS)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both ...

2005-03-01

156

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...

2002-12-01

157

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material ...

1999-09-20

158

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural ...

1990-05-01

159

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

160

Elimination of organics chemicals in aqueous solutions by gamma radiation processing  

International Nuclear Information System (INIS)

The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, 88.92 % to 15.0 KGy, ...

1992-08-16

161

Properties and morphology of PMMA/ABN blends obtained via MMA in situ polymerisation through {gamma}-rays  

Energy Technology Data Exchange (ETDEWEB)

Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.

2001-12-01

162

High current implantation of negative copper ions into silica glasses  

Energy Technology Data Exchange (ETDEWEB)

High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.

1997-12-01

163

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

164

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

165

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

166

Electron beam curable phenol-formaldehyde resin  

International Nuclear Information System (INIS)

The novolac type phenolic resins were synthesized and electron beam curing was carried out to the prepolymer obtained by the reaction of the phenolic resin and glycidyl meth acrylate in the presence of triethylbenzyl ammonium chloride. When the prepolymer and its mixtures with monomers were irradiated using electron beams at a dose rate of 3 Mrad/sec, the curing were completed at a dose 2.5 and 3 Mrad respectively. The effects of oxygen and that of hydroxyl group in the prepolymer on electron beam curing were also examined. (author).

167

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

168

Comparison of Atmospheric Dispersion Models Between PHWR and PWR  

International Nuclear Information System (INIS)

The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences

2010-10-01

169

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was ...

1983-12-01

170

Retrograde amnesia produced by electron beam exposure: casual parameters and duration of memory loss. Final report for November 84  

Energy Technology Data Exchange (ETDEWEB)

The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.

1985-01-01

171

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.

172

Creation and filling of thermoluminescence traps during irradiation  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model has been constructed to describe the creation and filling of thermoluminescence traps during irradiation. Processes considered include trap filling, recombinations both between free charges and between free and trapped charges and thermal de-trapping. Also a simple trap creation term, linear with dose, has been included. A computer program has been written in order to solve the system of differential equations describing the various charge carrier flows during irradiation. The model and the program are described and the results of the application of the model to some simple energy-level schemes are discussed. Thermal de-trapping and band-to-band recombinations can introduce a dose rate dependence into the accumulation of trapped charge, whilst trap creation leads to the supralinear growth of charge trapped at certain defects with increasing dose.

1986-01-01

173

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

174

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher ...

2010-04-15

175

A study of radiation embrittlement using simulation irradiation  

International Nuclear Information System (INIS)

Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional cluster nucleation sites to compensate for lower free point defect production. High dose ...

2008-10-13

176

Study on prepartion of polyethylene ion-exchange capillary by radiation induced graft co-polymerization  

International Nuclear Information System (INIS)

The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.

177

Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)

2006-11-13

178

Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty  

International Nuclear Information System (INIS)

An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.

2006-01-01

179

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...

2010-05-15

180

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...

2010-05-01

181

Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children  

International Nuclear Information System (INIS)

Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was ...

2005-05-01

182

Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer  

International Nuclear Information System (INIS)

Background and purpose: To compare 6 MV and 18 MV photon intensity modulated radiotherapy (IMRT) for non-small cell lung cancer. Materials and methods: Doses for a cohort of 10 patients, typical for our department, were computed with a commercially available convolution/superposition (CS) algorithm. Final dose computation was also performed with a dedicated IMRT Monte Carlo dose engine (MCDE). Results: CS plans showed higher D _9_5_% (Gy) for the GTV (68.13 vs 67.36, p = 0.004) and CTV (67.23 vs 66.87, p = 0.028) with 18 than with 6 MV photons. MCDE computations demonstrated higher doses with 6 MV than 18 MV in D _9_5_% for the PTV (64.62 vs 63.64, p = 0.009), PTV_o_p_t_i_m (65.48 vs 64.83, p = 0.014) and CTV (66.22 vs 65.64, p = 0.027). Dose inhomogeneity was lower with 18 than with 6 MV photons for GTV (0.08 vs 0.09, p = 0.007) and CTV (0.10 vs 0.11, p = ...

2007-01-01

183

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay ...

184

Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating  

International Nuclear Information System (INIS)

The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).

185

Role of Intravenous Omeprazole in Patients with High-Risk Peptic Ulcer Bleeding After Successful Endoscopic Epinephrine Injection: A Prospective Randomized Comparative Trial  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: Epinephrine injection is the most common endoscopic therapy for peptic ulcer bleeding. Controversy exists concerning the optimal dose of proton pump inhibitors (PPI) for patients with bleeding peptic ulcers after successful endoscopic therapy. The objective of this study was to determine the optimal dose of PPI after successful endoscopic epinephrine injection in patients with bleeding peptic ulcers. METHODS: A total of 200 peptic ulcer patients with active bleeding or nonbleeding visible vessels (NBVV) who had obtained initial hemostasis with endoscopic injection of epinephrine were randomized to receive omeprazole 40 mg infusion every 6 h, omeprazole 40 mg infusion every 12 h or cimetidine (CIM) 400 mg infusion every 12 h. Outcomes were checked at 14 days after enrollment. RE...

2006-01-01

186

Exclusion, exemption and clearance in the mining and minerals industry - A review of the concepts from a South African perspective  

International Nuclear Information System (INIS)

The risks from mining and processing of ores is reviewed on a generic basis with particular reference to some of the confusions which can arise due to lack of consistency or common logic in the use of exclusion, exemption and clearance. The difference in exclusion and exemption are challenged by comparing doses received in high background radiation areas and the doses received from a mining practice. The common principle of risk to the human species is not applied consistently. The differences between IAEA recommendations and local regulatory conditions are compared, and the use of exemption levels as clearance levels is considered. A case study on management of mine tailings is presented with special focus on the use of clearance levels. In all areas of review the interpretation of regulation is subject to confusion resulting from inconsistencies which can distort free market economics. (author).

1997-05-06

187

Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects  

Energy Technology Data Exchange (ETDEWEB)

Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...

1996-12-31

188

Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.  

Science.gov (United States)

In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use ...

2009-02-19

189

Experimental and theoretical studies of nuclear generation of ozone and its photolysis into singlet delta oxygen  

International Nuclear Information System (INIS)

A series of measurements of O_3 yield in nuclear induced O_2 and O_2-SF_6 discharges created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction are reported. Continuous irradiation at dose ratios of 10"1"5-10"1"7 eV.cm"-"3.s"-"1 and pulsed irradiation (approx.10 ms FWHM) at a peak dose rate of approx.10"2"0 eV.cm"-"3.s"-"1 were conducted. At the lower dose rates, SF_6 addition generally increased the ozone yield, which at the high dose rates, SF_6 addition decreased the observed ozone concentration. A numerical model was developed and applied to experimental conditions. The steady-state ozone concentration was found to be limited by the reaction O_3"- + O_3 #-># 2O_2 + O_2"-. A simplified analytical model of steady-state conditions was used to predict model sensitivity to various parameters. In addition to ...

190

The natural background approach to setting radiation standards  

International Nuclear Information System (INIS)

The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any ...

1979-03-09

191

Preparation of wood-polymer composites by using ionizing radiation  

International Nuclear Information System (INIS)

Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).

1982-05-01

192

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

193

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

Energy Technology Data Exchange (ETDEWEB)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT ...

2005-03-01

194

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and ...

2005-11-23

195

Particokinetics In Vitro: Dosimetry Considerations for In Vitro Nanoparticle Toxicity Assessments  

Energy Technology Data Exchange (ETDEWEB)

The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of ...

2007-02-01

196

Cell death (apoptosis) in mouse intestine after continuous irradiation with gamma rays and with beta rays from tritiated water  

Energy Technology Data Exchange (ETDEWEB)

Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose ...

1989-04-01

197

HDR and MDR intracavitary treatment for carcinoma of the uterine cervix. A prospective randomized study  

Energy Technology Data Exchange (ETDEWEB)

Aim: Treatment of carcinoma of the uterine cervix by remote afterloading brachytherapy has been accompanied with new isotopes having dose rates different from the classical low-dose rate (LDR) radium source. The dose rate conversion factor from LDR to high-dose rate (HDR) found to be around 0.54 in most studies. As regards medium-dose rate (MDR) brachytherapie, the published data are very few and the experience is still short. In this study the experience of Osaka University Hospital with micro-HDR-Selectron and Selectron-MDR, as a preliminary report of the clinical trial, is presented. Results: The 3-year survival and loco-regional control rates for both modalities were nearly equivalent (62% and 67% for HDR and 68% and 74% for MDR)(totally 45 patients). The ...

1997-03-01

198

Experimental parameters differentially affect the humoral response of the cholera-toxin-based murine model of food allergy  

DEFF Research Database (Denmark)

Background: Recent studies have developed a murine model of IgE-mediated food allergy based on oral coadministration of antigen and cholera toxin (CT) to establish a maximal response for studying immunopathogenic mechanisms and immunotherapeutic strategies. However, for studying subtle immunomodulating factors or factors effective during response initiation, this maximal response-based model is less suitable due to a lack of sensitivity. Therefore, in attempts to identify essential parameters to fine-tune the immune response towards a submaximal level, potentially more sensitive, we were interested in characterizing the individual effects of the parameters in the CT-based model: CT dose, antigen type and dose, and number of immunizations. Methods: BALB/c mice were orally sensitized weekly for 3 or 7 weeks with graded doses of CT and various food antigens (soy-trypsin inhibitor, ovalbumin or ovomucoid). ...

2003-01-01

199

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were ...

1993-02-01

200

Control of population dose equivalent from naturally occurring radionuclides in building materials  

International Nuclear Information System (INIS)

Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for ...

201

Verification of the Gaspar dose assessment module used in Maxigasp and Popgasp  

Energy Technology Data Exchange (ETDEWEB)

The GASPAR module utilized in MAXIGASP and POPGASP has been verified by hand calculations. The program operates as documented by the NRC [Eckerman et. al. 1980]. Equations used in the code to calculate downwind deposition rates, concentrations in air, on ground surfaces, and in vegetables, meat, and milk are provided in this report.

1992-12-31

202

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the ...

2007-11-05

203

Non-neoplastic pulmonary disease from inhaled radon daughters with uranium ore dust in beagle dogs  

International Nuclear Information System (INIS)

Daily exposures of adult beagle dogs to inhaled radon daughters plus uranium ore dust, with and without concurrent cigarette smoking, for 2 to 5-1/2 yr have produced massive pulmonary fibrosis and severe emphysema. The cumulative exposure doses are similar to those associated with a 5-fold or greater increase in death rate of uranium miners due to chronic respiratory insufficiency, including pneumoconiosis, pulmonary fibrosis, and emphysema.

1977-05-01

204

Localization of an anti-tumour monoclonal antibody in human tumour xenografts: kinetic and quantitative studies with the 791T/36 antibody  

International Nuclear Information System (INIS)

Studies have been performed with an anti-osteogenic sarcoma monoclonal antibody 791T/36 and human tumour xenografts to examine some of the quantitative and kinetic aspects of tumour localization. The influence of variations in tumour size and site and antibody dose on the extent and rate of specific antibody localization have been examined, together with the site of intratumoural deposition of the antibody. (UK).

205

Calculated fluence spectra at neutron therapy facilities  

International Nuclear Information System (INIS)

The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).

1995-11-13

206

Advanced composite materials made by radiation processing  

Energy Technology Data Exchange (ETDEWEB)

An industrial EB processing line is started to produce cement-bound /CB/ chipboard with radiation cured acrylic coating. The basic features of this line are presented here. The main technological parameters of coating such as: effect of oligomer- and monomer reactivity, monomer functionality, dose-rate and inerting atmosphere on the progress of curing have been discussed. The EB processed CB board is an advanced composite material for the modern lightweight architecture.

1988-01-01

207

Neutron monitoring on cold fusion experiments  

International Nuclear Information System (INIS)

A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).

1992-10-01

208

Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K  

Energy Technology Data Exchange (ETDEWEB)

Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with temperature. The melting point of each sample was also ...

1994-08-15

209

Mechanisms of renal handling of lead  

International Nuclear Information System (INIS)

The relative roles of glomerular filtration, tubular reabsorption and tubular secretion in lead handling were evaluated using renal clearance technique, stop-flow analysis, and renal lead accumulation. In addition, the effect of altering acid-base status on renal handling of Pb was determined. Clearance of ultrafilterable lead was measured in anesthetized dogs during infusion of "2"0"3Pb with small doses of carrier Pb(0.5 to 50 #mu#g/kg/h). Filterable lead concentration was estimated by in vitro ultrafiltration of non-anticoagulated plasma. Fractional excretion of Pb was calculated using creatinine clearance to estimate glomerular filtration rate. Dogs in acute metabolic acidosis had the lowest fractional excretion of ultrafilterable Pb (< 0.1); those in alkalosis had high fractional Pb excretion (0.75 to 2.5) while normal dogs were intermediate (0.1 to .4). The fractional excretion of Pb during metabolic alkalosis varied with the ...

210

Low dose effects - is the fear more dangerous than the radiation?  

Energy Technology Data Exchange (ETDEWEB)

The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...

1996-01-01

211

Improvement of banana through biotechnology and mutation breeding  

International Nuclear Information System (INIS)

Protocols were standardized for in vitro propagation of several elite and diverse banana accessions using shoot tip explants. Tissue culture raised plants were field planted at multiple locations. Studies were undertaken for the induction of mutations using multiple shoot cultures of six selected cultivars, Shreemanti (AAA), Basrai (AAA), Lal Kela (AAA), Rasthali (AAB), Karibale Monthan (ABB) and a wild diploid (BB). These shoot cultures were irradiated at different doses of gamma rays (0-100 Gy) and subcultured thrice (up to M_1V_3) to separate shimeras, followed by induction of rooting (M_1V_4). In general, the rate of multiplication had a negative association with the dose of gamma rays. Enhanced multiplication of shoots was noticed at lower doses. The proliferation of shoots was arrested beyond 50 Gy and a dose of 70 Gy was completely lethal for all the genotypes studied. The ...

1998-10-01

212

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any ...

213

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the ...

2004-11-01

214

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1992-01-01

215

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1991-10-01

216

Estimation of cancer risks from radiotherapy of benign diseases  

Energy Technology Data Exchange (ETDEWEB)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of ...

2006-08-15

217

Estimation of cancer risks from radiotherapy of benign diseases  

International Nuclear Information System (INIS)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of ...

2006-08-01

218

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total ...

219

Age and carcinogenesis of "2"3"9Pu  

International Nuclear Information System (INIS)

The late effects of "2"3"9Pu have been studied after its administration to perinatal, juvenile and adult rats. Adults and weanlings were injected intravenously, newborns intracardially and 19-day foetuses by intravenous injection of the dam. Dose levels were selected to deliver radiation doses of approximately 7, 23, or 70 rads to the femur of all ages during the first 10 days post injection; in general these values were achieved as shown by tissue analysis. Dose rates subsequently diverged, resulting in widely varying cumulative radiation doses for the four age groups. Survival times of rats exposed post-natally were progressively decreased by increasing dose. No decrement in survival was found for those exposed prenatally. Bone tumour incidence was increased by exposure to Pu in all age groups. The younger rats were less sensitive on an administered ...

1979-03-30

220

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.

1980-03-01

221

Local control of Ewing's sarcoma: an analysis of 67 patients  

International Nuclear Information System (INIS)

Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).

222

FFTF reactor characterization program  

International Nuclear Information System (INIS)

Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.

223

Patient- and delivery-level factors related to acceptance of HIV counseling and testing services among tuberculosis patients in South Africa: a qualitative study with community health workers and program managers  

UK PubMed Central (United Kingdom)

BackgroundSouth Africa has a high tuberculosis (TB)-human immunodeficiency virus (HIV) coinfection rate of 73%, yet only 46% of TB patients are tested for HIV. To date, relatively...Full Text Available

224

Induction of Antibody Responses to African Horse Sickness Virus (AHSV) in Ponies after Vaccination with Recombinant Modified Vaccinia Ankara (MVA)  

UK PubMed Central (United Kingdom)

BackgroundAfrican horse sickness virus (AHSV) causes a non-contagious, infectious disease in equids, with mortality rates that can exceed 90% in susceptible horse populations....Full Text Available

225

Feasibility of Collecting Diary Data From Asthma Patients Through Mobile Phones and SMS (Short Message Service): Response Rate Analysis and Focus Group Evaluation From a Pilot Study  

UK PubMed Central (United Kingdom)

BackgroundSelf-management of asthma may improve asthma outcomes. The Internet has been suggested as a tool for the monitoring and self-management of asthma....Full Text Available

226

Disagreements between central clinical events committee and site investigator assessments of myocardial infarction endpoints in an international clinical trial: review of the PURSUIT study  

UK PubMed Central (United Kingdom)

BackgroundLimited information has been published regarding how specific processes for event adjudication can affect event rates in trials. We reviewed nonfatal myocardial infarctions...Full Text Available

2001-01-01

227

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

228

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

229

Characterization of CTX-M ESBLs in Enterobacter cloacae, Escherichia coli and Klebsiella pneumoniae clinical isolates from Cairo, Egypt  

UK PubMed Central (United Kingdom)

BackgroundA high rate of resistance to 3rd generation cephalosporins among Enterobacteriaceae isolates from Egypt has been previously reported. This study aims to characterize...Full Text Available

230

Clinical outcomes and risk factors for technical and clinical failures of self-expandable metal stent insertion for malignant colorectal obstruction  

British Library Electronic Table of Contents (United Kingdom)

BackgroundAlthough self-expandable metal stent (SEMS) insertion is widely used for relief of malignant colorectal obstructions, the immediate technical and clinical failure rates of SEMSs and the associated risk factors remain largely unknown. ObjectiveTo identify rates and factors predictive of technical and clinical failure of SEMSs when their use is attempted for the decompression of malignant colorectal obstruction. DesignRetrospective chart review. SettingA tertiary-care academic medical center in South Korea. PatientsThis study involved a total of 412 patients with malignant colorectal obstruction in whom SEMS insertion was attempted. InterventionPlacement of colonic SEMSs. Main Outcome MeasurementsTechnical success and immediate and long-term clinical success rates. ResultsTechnical...

2011-01-01

231

A report on the CCNA 2007 professional practice analysis.  

Science.gov (United States)

The purpose of this column is to present the results of the 2007 Professional Practice Analysis (PPA) of the field of nurse anesthesia, conducted by the Council on Certification of Nurse Anesthetists. The PPA used survey and rating scale methodologies to collect data regarding the relative emphasis of various aspects of the nurse anesthesia knowledge domain and competencies. A total of 3,805 survey responses were analyzed using the Rasch rating scale model, which aggregates and transforms ordinal (rating scale) responses into linear measures of relative importance and frequency. Summaries of respondent demographics and educational and professional background are provided, as well as descriptions of how the survey results are used to develop test specifications. The results of this analysis provide evidence for the content outline and test specifications (content percentages) and thus serve as a basis of ...

2009-06-01

232

The optimum modification of energy spectra using FFT convolution/multigrid superposition algorithm on the focus radiation treatment system  

International Nuclear Information System (INIS)

In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The ...

2003-06-01

233

Physics and quality assurance of low dose rate brachytherapy  

International Nuclear Information System (INIS)

Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure ...

234

Key impact parameters for application of alternative source term to Kori unit 1  

International Nuclear Information System (INIS)

The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% ...

2010-08-01

235

Harm to the cell and harm to the individual  

International Nuclear Information System (INIS)

Exposures from most natural and artificial sources, with the exception of those from medical radiology, are received at average dose rates of only a few microsieverts a day. Such risks as may be caused by these exposures are most unlikely to be determined with precision directly by epidemiological studies of populations exposed at these low rates. They may, however, be reliably inferred from the observed risks of exposure to rather larger doses delivered at higher dose rates in the light of the increasing knowledge of the phenomena involved in the initial cellular damage, the extent to which such damage is incorrectly repaired, and the processes which intervene between the genetic or other harm to cells and the likelihood of its final expression in inherited abnormality, in cancer development, or in defective foetal or embryonic growth. Current studies are of ...

1983-04-11

236

Disposal of De-ionizer Vessels Highly Contaminated with 14Carbon at SRS  

International Nuclear Information System (INIS)

At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. This investigation implemented a more rigorous evaluation of the ...

2008-01-01

237

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with ...

1990-09-16

238

Uptake of Pb by human skeleton and comparative metabolism of Pb and alkaline earth elements  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the retention of /sup 47/Ca and of /sup 203/Pb were made following their administration by intravenous injection. Translocation to bone was measured by ..gamma.. counting the feet of subjects. Uptake by bone of /sup 203/Pb was comparatively slow and extrapolation to the whole skeleton indicated that 20% of the dose has been taken up within 20 days. By time, a similar fraction of the dose has been excreted in urine. Uptake by bone of /sup 47/Ca was about 1.5-2 times the amount excreted in urine. Both the uptake by bone, and its excretion in urine, were more rapid than that of /sup 203/Pb due to the greater attachment of the latter to red blood cells. However, the plasma clearance rate for Pb, like that of Sr, was greater than that of Ca.

1984-12-01

239

The prooxidant-antioxidant homeostasis in Guinea pigs after exposure to fractionated low-low X-radiation and correction of its disturbances with antioxidant complex treatment  

International Nuclear Information System (INIS)

The state of prooxidant-antioxidant homeostasis in Guinea pigs exposed to whole-body fractionated X-irradiation (5 fractions of 0.2 Gy at a 24 hr interval, up to total dose of 1.0 Gy, at a dose rate of 0.425 R/min) and a possibility of its disturbance correction with the complex of vitamins C, E and P was studied. Accumulation of primary and secondary lipid peroxidation products, decrease of the ascorbic acid content, increase of the content of its oxidized forms (dehydroascorbic acid and diketogulonic acid) in radiosensitive and radioresistant organs were found. Antioxidant complex administration reduced the disturbances of prooxidant-antioxidant homeostasis, but did not provide complete normalization.

240

Respiratory exposure in buildings due to radon progeny  

International Nuclear Information System (INIS)

The #alpha# radiation dose to the lungs of people who live in buildings constructed of some granites, low density concretes, and gypsum boards is higher than for residents of most other types of dwellings due to the air-borne progeny of radon. There is evidence that sealing the interior surfaces with epoxy paint, for example, can reduce the #alpha# dose to the lung significantly without a compensating increase in whole-body exposure to the #gamma#-rays from radon progeny. Based on the incidence rates for lung cancer in uranium miners, a concentration of radon of the order of 1 to 5 pCi/l. appears to be a reasonable limit for 'lifetime' exposure indoors for 'typical' home ventilation conditions. (author).

1976-01-01

241

Radiation yield of oxygen-based radicals in hyperquenched glassy water gamma-irradiated at 77 K  

Energy Technology Data Exchange (ETDEWEB)

Hyperquenching of liquid water with cooling rates of 10{sup 6}-10{sup 7} K s{sup -1} yields glassy water. Upon {gamma}-irradiation at 77 K, the only paramagnetic species accumulating in hyperquenched glassy water are the hydroxyl and hydroperoxyl radicals. There are no hydrogen atoms or electrons seen by the ESR technique. For irradiation doses up to about 70 kGy, the relative contributions of hydroxyl and hydroperoxyl radicals to the total amount of paramagnetic species remain virtually constant. The total amount of paramagnetic species, n, is sublinear in dose, d, well approximated by n=8.55x10{sup 16}d{sup 0.8} for n in spin g{sup -1} and d in kGy.

1998-12-01

242

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

243

Radiation processed composite materials of wood and elastic polyester resins  

International Nuclear Information System (INIS)

The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite ...

1982-09-19

244

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 ...

245

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

246

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

247

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.

248

Effect of gamma rays on grafting parameters and liquid retention property of cassava starch-g-PAN  

International Nuclear Information System (INIS)

Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.

1992-10-20

249

ESR dating of fault rocks  

Energy Technology Data Exchange (ETDEWEB)

Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then trow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected from the Yangsan fault system. ESR dates from the this fault system range from 870 to 240 ka. Results of this research suggest that long-term cyclic fault activity continued into the pleistocene.

2002-03-15

250

Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.

2006-01-01

251

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration facility and calibration ...

2008-11-19

252

Coloring of cultured pearls by gamma-rays irradiation  

International Nuclear Information System (INIS)

Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for cultured blue pearls. ...

253

Chain radiation-chemical cross-linking of polyethylene under high pressures. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Regularities in the radiation cross-linking of low-density polyethylene under various conditions of ..gamma..-irradiation were studied. It is shown that at the 0.5 GPa pressure and 450 K the gel formation is initiated at doses of about 1 kGy, i.e. at doses 10 times as low as compared to normal conditions. Abnormally high rate of radiation cross-linking at high temperature and high pressure is an evidence of changes in the mechanism of polyethylene, radiation cross-linking, i.e. of the process transition from nonchain to chain conditions. Decrease in the potential barriers of macroradical reactions with macromolecules is the most probable reason of change in the polymer cross-linking nature.

1984-01-01

254

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...

2006-01-01

255

Equivalent dose estimation using a single aliquot of polymineral fine grains  

International Nuclear Information System (INIS)

We have tested the suitability of a new single-aliquot regenerative-dose protocol for estimating the equivalent dose (D_e) in polymineral fine grains extracted from colluvia from various sites in Germany. First, we report the behaviour of three OSL signals: (i) blue-stimulated, (ii) infrared-stimulated luminescence, and (iii) blue-stimulated luminescence following infrared (IR) stimulation, using a near-UV (290-380 nm) detection window in each case. For these three signals, there is a significant change in sensitivity with regeneration cycle; this change can be compensated for using the response to a fixed test dose after each natural or regenerated measurement. The source of the three luminescence signals is then investigated using pulse-anneal and elevated-temperature experiments. Fading tests on laboratory-induced signals show that although the IR signals fade by up to 23% in 15 days at 100 deg. C, the post-IR blue ...

2001-02-01

256

Dosimetric evaluation and therapeutic response to iodine-131 labelled lipiodol in treatment of hepatocellular carcinomas; Evaluation dosimetrique et reponse therapeutique de la curietherapie metabolique des hepatocarcinomes par le lipiodol marque par l'iode 131  

Energy Technology Data Exchange (ETDEWEB)

Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...

2006-12-15

257

Elk and Deer Study, Material Disposal Area G, Technical Area 54: Source document  

Energy Technology Data Exchange (ETDEWEB)

As nuclear research has become more prevalent, environmental contamination from the disposal of radioactive waste has become a prominent issue. At Los Alamos National Laboratory (LANL) in northern New Mexico, radioactive contamination from disposal operations has raised some very specific concerns. Material Disposal Area G (Area G) is the primary low-level radioactive waste disposal site at LANL and occupies an area adjacent to land belonging to the Native American community of the Pueblo of San Ildefonso. Analyses of soil and vegetation collected from the perimeter of Area G have shown concentrations of radionuclides greater than background concentrations established for northern New Mexico. As a result, Pueblo residents had become concerned that contaminants from Area G could enter tribal lands through various ecological pathways. The residents specifically questioned the safety of consuming meat from elk and deer that forage near Area G and then migrate onto ...

1999-09-01

258

Modeling marrow damage from response data: Morphallaxis from radiation biology to benzene toxicity  

Energy Technology Data Exchange (ETDEWEB)

Consensus principles from radiation biology were used to describe a generic set of nonlinear, first-order differential equations for modeling of toxicity-induced compensatory cell kinetics in terms of sublethal injury, repair, direct killing, killing of cells with unrepaired sublethal injury, and repopulation. This cellular model was linked to a probit model of hematopoietic mortality that describes death from infection and/or hemorrhage between {approximately} 5 and 30 days. Mortality data from 27 experiments with 851 doseresponse groups, in which doses were protracted by rate and/or fractionation, were used to simultaneously estimate all rate constants by maximum-likelihood methods. Data used represented 18,940 test animals distributed according to: (mice, 12,827); (rats, 2,925); (sheep, 1,676); (swine, 829); (dogs, 479); and (burros, 204). Although a long-term, repopulating hematopoietic stem cell is ancestral to all ...

1995-12-01

259

High dose rate /sup 60/Co remote afterloading irradiation in cancer of the cervix in Haiti, 1977-1984  

Energy Technology Data Exchange (ETDEWEB)

From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: Stage I of 100% (3/3), Stage II of 82% (9/11), Stage III of 80% (47/59), and Stage ...

1988-06-01

260

Clinical implementation of enhanced dynamic wedges into the Pinnacle treatment planning system: Monte Carlo validation and patient-specific QA  

International Nuclear Information System (INIS)

The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in ...

2009-01-21

261

Natural and anthropogenic "1"4C in the UK coastal marine environment  

International Nuclear Information System (INIS)

Prior to this study, almost no up-to-date information was available on the 'background' level of "1"4C present in the water and biota of the UK coastal marine environment. The weighted mean "1"4C activity derived from the lowest activities of dissolved inorganic carbon (DIC) and biota for sites which are remote from potential sources is 247#centre dot#6#+-#1#centre dot#0 Bq kg"-"1 carbon. This is proposed as the best estimate of the natural/weapons testing 'background' for 1995 and should be subtracted from the activity derived for any sample to establish the excess due to UK anthropogenic inputs. "1"4C activities in the DIC component of seawater and a range of marine biota are significantly enhanced above the expected 'background' value in the environment around the British Nuclear Fuels plc reprocessing plant at Sellafield, Cumbria, NW England and Amersham International plc, Cardiff, Wales. The enrichments around ...

1997-07-01

262

Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources  

CERN Document Server

We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities > 100 mJy at 500 um, but are not visible in existing optical imaging. We fit light profiles to each component of the lensing systems in Spitzer IRAC 3.6 and 4.5 um data and successfully disentangle the foreground lens from the background source in each case, providing important constraints on the spectral energy distributions (SEDs) of the background SMG at rest-frame optical-near-infrared wavelengths. The SED fits show that these two SMGs have high dust obscuration with Av ~4 to 5 and star formation rates of ~100 M_sun/yr. They have low gas fractions and low dynamical masses compared to 850 um selected galaxies.

2010-01-01

263

Single charged top-pion production at next generation #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The future e"+e"- linear colliders can also operate in the e#gamma# or #gamma##gamma# modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process #gamma##gamma# #-># tb-bar#PI#_t"-. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode #PI#_t"- #-># bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in #gamma##gamma# mode at the TeV energy scale

2008-09-01

264

Search for Neutron-Antineutron Oscillations Using Multiprong Events in Soudan 2  

CERN Document Server

We have searched for neutron-antineutron oscillations using the 5.56 fiducial kiloton-year exposure of the Soudan 2 iron tracking calorimeter. We require candidate n-nbar occurrences to have .GE. 4 prongs (tracks and showers) and to have kinematics compatible with nbar-N annihilation within a nucleus. We observe five candidate events, with an estimated background from atmospheric neutrino and cosmic ray induced events of 4.5 \\pm 1.2 events. Previous experiments with smaller exposures observed no candidates, with estimated background rates similar to this experiment. We set a lifetime lower limit for oscillation time in iron: T_A(Fe) > 7.2x10^{31} years. The corresponding lower limit for oscillation of free neutrons is \\tau_{n-nbar} > 1.3x10^8 seconds.

2002-01-01

265

New neutron capture and total cross section measurements on {sup 88}Sr and their impact on s-process nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.

1998-11-01

266

Radiation processing as a post-harvest quarantine control for raisins, dried figs and dried apricots  

International Nuclear Information System (INIS)

The commercially packed samples of raisins, dried figs and dried apricots were irradiated using doses in the range of 0.5-1.0 kGy for disinfestation and 0.5-5.0 kGy for sensory analysis with the dose rate ranging from 1.44 to 1.92 kGy/h. Pests on dried fruits were evaluated after 0, 1, 2 and 3 months of storage for irradiated dried figs and 1, 3, 6 and 12 months of storage for raisins and dried apricots. Sensory analysis of dried figs, dried apricots and raisins were carried out after 0, 1, 3, 6 and 12 months of storage. The results indicated that radiation processing at low doses (#approx#1.0 kGy) is an effective post-harvest treatment and quarantine control for these products with no adverse effects on sensory (marketing) attributes.

2006-03-01

267

Radiation factors specifying safety in reactor compartments handling in the process of decommissioning nuclear-powered submarines  

International Nuclear Information System (INIS)

The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...

1996-03-10

268

Photochemically and Pharmacological studies of Maytenus Frosskaoliana  

International Nuclear Information System (INIS)

Column chromatography of the petroleum ether and chloroformic extracts of Maytenus Forsskaoliana afforded four compounds: friedilin1, B-amyrin 2, B-sitosterol 3 and betulin 4. The structure of these compounds were established on bases of spectral (IR,MS,H and C-NMR)as well as physical data. Antimicrobial activity for extracts indicated weak potency (200ug/ml) while betulin4 showed a pronounced activity (MIC and MBC 20ug/ml).The cytotoxic activity of beutalin4 significantly indicated promising activity (IC50 40ug/ml) on both HeLa and Hep-2 cells. The pharmacological activity of diferent extracts showed sedative effect, slowing respiration, dose -dependent decrease in the arterial blood pressure by 40.1mm Hg (at adose 200mg /kg),decrease in the heart rate 67.3% (at a dose 50mg /kg)and decrease in the body temperature by 4.2C after 2 hrs (at a dose 200mg /kg). (author)

269

Inherited sterility induced in progeny of gamma irradiated males and females spiny bollworm, Earias Insulana boisd ,effect on fecundity, fertility and mating  

International Nuclear Information System (INIS)

adult males and females, less than 24 hours old, of the spiny bollworm, Earias Insulana boisd. were irradiated with sub sterilizing doses of 50,80,100 and 150 gray (Gy). treated moths were out crossed with normal adults and observed for their ability to reproduce. inherited deleterious effects resulting from irradiation of p_1 moths were recorded for several generations. the reduction in both fecundity and egg viability increased by increasing the dose applied to p_1 adult moths .at all tested doses, the females were more radiosensitive than males, as for reduction in fecundity and egg viability. the progeny from irradiated parental females are not as sterile as the progeny from irradiated parental males. the reduction of egg hatching continued in the progeny of irradiated males through F_1 and to lesser extent through F_2 .on the other hand , irradiation of P_1 females reduced the rate of egg hatching ...

2004-02-01

270

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-12-01

271

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-01-01

272

Evaluation of fungal burden of medicinal plants submitted to gamma radiation process after 30 days  

International Nuclear Information System (INIS)

Forty samples of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia and Cassia angustifolia), purchased from pharmacies and street market in the five cities of Sao Paulo State, were irradiated using a "6"0Co gamma ray source (Gammacell) with a dose of 10.0 kGy, delivered at dose rate of 3.0 kGy/h. Nonirradiated samples were used as controls of fungal isolates. For fungal counts and identification in medicinal plants a serial dilutions from 10"-"1 to 10"-"6 of the samples were seeded in duplicates and plated using the method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. Mycological analysis of control samples revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi. The process of gamma radiation was effective in reducing the number of colony forming units (cfu/g) in all irradiated samples of medicinal plants after 30 days, ...

273

Effects of epidermal growth factor on bone formation and resorption in vivo  

Energy Technology Data Exchange (ETDEWEB)

The effects of mouse epidermal growth factor (EGF) on bone formation and resorption were examined in male mice. EGF administration (2-200 ng.g-1.day-1 ip for 7 days) induced a dose-dependent rise in plasma EGF levels that remained within physiological range. Histomorphometric analysis of caudal vertebrae showed that EGF (20 and 200 ng.g-1.day-1) reduced the endosteal matrix and mineral appositional rates after 5 days of treatment as measured by double (3H)proline labeling and double tetracycline labeling, respectively. This effect was transitory and was not observed after 7 days of EGF administration. EGF administered for 7 days induced a dose-dependent increase in the periosteal osteoblastic and tetracycline double-labeled surfaces. At high dosage (200 ng.g-1.day-1) EGF administration increased the osteoclastic surface and the number of acid phosphatase-stained osteoclasts, although plasma calcium remained normal. The ...

1990-02-01

274

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...

2007-01-01

275

Doping of silicon carbide by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some recent results on doping of 4H- and 6H-SiC by ion implantation. The doses and energies used are between 10{sup 9} and 10{sup 15} cm{sup -2} and 100 keV and 5 MeV, respectively, and B and Al ions (p-type dopants) are predominantly studied. After low dose implantation ({<=}10{sup 10} cm{sup -2}) a strong compensation is observed in n-type samples and this holds irrespective of implantation temperature up to 600 C. However, at higher doses (10{sup 14}-10{sup 15} Al/cm{sup 2}) the rate of defect recombination (annihilation) increases substantially during hot implants ({>=}200 C), and in these samples one type of structural defect dominates after post-implant annealing at 1700-2000 C. The defect is identified as a dislocation loop composed of clustered interstitial atoms inserted on the basal plane in the hexagonal crystal structure. Finally, transient enhanced ...

2001-07-01

276

Different doses of bone morphogenetic protein 4 promote the expression of early germ cell-specific gene in bone marrow mesenchymal stem cells  

British Library Electronic Table of Contents (United Kingdom)

Bone morphogenetic protein (BMP)-4 has a crucial role on primordial germ cells (PGCs) development in vivo which can promote stem cell differentiation to PG-like cells. In this study, we investigated the expression of Mvh as one of the specific genes in primordial germ cells after treatment with different doses of BMP4 on bone mesenchymal stem cells (BMSCs)-derived PGCs. Following isolation of BMSCs from male mouse femur and tibia, cells were cultured in medium for 72?h. Passage 4 murine BMSCs were characterized by CD90, CD105, CD34, and CD45 markers and osteo-adipogenic differentiation. Different doses of BMP4 (0, 0.01, 0.1, 1, 5, 25, 50, and 100?ng/ml) were added to BMSCs for PGCs differentiation during 4-days culture. Viability percent, proliferation rates, and expression of Mvh gene wer...

2011-01-01

277

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential ...

1997-04-01

278

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the gas industry, monitoring ...

2006-07-01

279

Risk of leukaemia following intravenous treatment with "2"2"4Ra - results of a long term follow-up study of ankylosing spondylitis patients  

International Nuclear Information System (INIS)

In an epidemiological study of the somatic late effects risk following incorporation of a short lived #alpha#-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of "2"2"4Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 #mu#Ci) of "2"2"4Ra each, given at weekly intervals; this would result in an cumulative #alpha#-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases expected, ...

1993-09-28

280

Variability of infrared stimulated luminescence properties from fractured feldspar grains  

Energy Technology Data Exchange (ETDEWEB)

A series of OSL properties of fragments from split feldspar grains have been investigated. These are (1) the response to a radiation dose, (2) the recycling of corrected induced luminescence (L{sub i}/T{sub i}), (3) the corrected natural luminescence (L{sub N}/T{sub N}), (4) the corrected thermal transfer luminescence (termed herein L{sub tt}/T{sub tt}) and, (5) the rate of anomalous fading ('g'). It was found that the parameters of different parts of the same grain are the same. The relative uncertainty, at the 2 sigma level, at which we can claim that the measured parameters are correlated, is generally less than 5% but is ca 40% for the anomalous fading rate due to measurement uncertainty. For young partially bleached sediments, the result is that one could use one fragment to evaluate the equivalent dose and another to assess the contribution of thermal transfer resulting from ...

2003-10-01

281

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were ...

2006-11-13

282

Quantification of antibiotic drug potency by a two-compartment radioassay of bacterial growth  

Energy Technology Data Exchange (ETDEWEB)

The two-compartment radioassay for microbial kinetics based on continuous measurement of the {sup 14}CO{sub 2} released by bacterial metabolism of 14C-labeled substrate offers a valuable approach to testing the potency of antimicrobial drugs. By using a previously validated radioassay with gram-positive and gram-negative bacteria, a group of protein synthesis inhibitors was evaluated for their effect on microbial growth kinetics. All tested drugs induced changes in both the slopes and intercepts of the growth curves. An exponential growth model was applied to quantify the drug effect on the processes of bacterial {sup 14}CO{sub 2} liberation and cell generation. The response was measured in terms of a generation rate constant. A linear dependence of the generation rate constant on the dose of spectinomycin was observed with Escherichia coli. Sigmoidal-shaped curves were found in the assays of chloramphenicol and ...

1990-06-01

283

Ozone synthisis in charged particle induced noble gas-oxygen and noble gas-oxygen-sulfur hexafluoride discharges  

International Nuclear Information System (INIS)

A series of experimental measurements of ozone concentration produced by irradiation of noble gas (He, Ne, and Ar)-O_2 and noble gas-O_2- SF_6 mixtures with energetic (MeV) helium and lithium ions are reported. Continuous irradiations at dose rates of 10"1"5-10"1"7 eV cm"-"3 S"-"1 for a few hundred milliseconds were used. The resulting ozone concentration was found to be nonlinear with dose rate for a given irradiation time. This nonlinearity was effectively reduced by an increase in noble gas pressure. Few mole percent addition of SF_6 generally resulted in an increase in the ozone concentration. This increase was highest for lower noble gas pressures and longer irradiation times. Further SF_6 addition, however, caused a reduction in the ozone concentration. Results are explained by considering the relevant reactions responsible for ozone production and loss.

284

A new approach towards anomalous fading correction for feldspar IRSL dating - tests on samples in field saturation  

Energy Technology Data Exchange (ETDEWEB)

Anomalous fading of the feldspar infrared stimulated luminescence (IRSL) signal hampers possibilities of using feldspar IRSL to obtain burial ages for sediments beyond the dating range of quartz optically stimulated luminescence. Here, we propose a new approach to quantify anomalous fading of the feldspar IRSL signal over geological burial times based on laboratory fading experiments. The approach builds on the description of the quantum mechanical tunnelling process recently proposed by Huntley [2006. An explanation of the power-law decay of luminescence. J. Phys. Condensed Matter 18, 1359-1365]. We show that our methods allow the construction of un-faded and natural IRSL dose-response curves as well as anomalous fading rates in field saturation. The predicted level of field saturation closely approximates the measured saturation level for five samples from fluvial deposits (Lower Rhine) known to be older than 1 Ma. The modelled anomalous ...

2008-02-15

285

Postremediation dose assessment for the former Alba Craft Laboratory site, Oxford, Ohio  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates were calculated for the former Alba Craft Laboratory site in Oxford, Ohio, which was involved in machining of uranium metal in the 1950s for the U.S. atomic energy program. The site is not currently being used. The residual radioactive material guidelines (RESRAD) computer code, which implements the methodology described in the US Department of Energy`s (DOE`s) manual for establishing residual radioactive material guidelines, was sued in this evaluation. Three potential land use scenarios were considered for the former Alba Craft site; the scenarios vary with regard to the type of site use, time spent at the site by the exposed individual, and sources of food consumed. Scenario A (a possible land use scenario) assumed industrial use of the site; Scenario B (a likely future land use scenario) assumed residential use of the site; and Scenario C (a possible but unlikely land use scenario) assumed the presence ...

1996-04-01

286

Modeling human risk: Cell & molecular biology in context  

Energy Technology Data Exchange (ETDEWEB)

It is anticipated that early in the next century manned missions into outer space will occur, with a mission to Mars scheduled between 2015 and 2020. However, before such missions can be undertaken, a realistic estimation of the potential risks to the flight crews is required. One of the uncertainties remaining in this risk estimation is that posed by the effects of exposure to the radiation environment of outer space. Although the composition of this environment is fairly well understood, the biological effects arising from exposure to it are not. The reasons for this are three-fold: (1) A small but highly significant component of the radiation spectrum in outer space consists of highly charged, high energy (HZE) particles which are not routinely experienced on earth, and for which there are insufficient data on biological effects; (2) Most studies on the biological effects of radiation to date have been high-dose, high dose-rate, whereas in ...

1997-06-01

287

Deterministic calculations of radiation doses from brachytherapy seeds  

International Nuclear Information System (INIS)

Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software ...

2003-08-17

288

Treatment of hematological malignancies with nonmyeloablative, HLA-haploidentical bone marrow transplantation and high dose, post-transplantation cyclophosphamide  

British Library Electronic Table of Contents (United Kingdom)

Hematopoietic stem cell transplantation provides the only potential curative option in many patients with hematological malignancies. Finding a suitably matched donor in a timely manner is often difficult. However, most patients have a partially HLA-mismatched (HLA-haploidentical) first-degree relative readily available. Historically, HLA-haploidentical bone marrow transplantation (BMT) has been considered extremely high risk due to high rates of life-threatening graft-versus-host disease (GVHD) and non-relapse mortality (NRM). Modifications of the stem cell graft, such as T-cell depletion, have resulted in poor rates of engraftment. We have recently completed a phase II clinical trial of nonmyeloablative HLA-haploidentical hematopoietic BMT followed by post-transplantation high-cyclophosp...

2011-01-01

289

Activation analysis of target debris in the national ignition facility  

International Nuclear Information System (INIS)

The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)

1999-09-12

290

Superconductivity of neutron irradiated Mo_3Os  

International Nuclear Information System (INIS)

The effect of high energy neutron irradiation (E > 1 MeV) on the superconducting transition temperature, Tsub(c), of the A-15 compound Mo_3Os is reported. Tsub(c) was found to decrease with increasing neutron dose, but at a rate considerably less than observed in other A-15 compounds composed of non-transition metals. The results lend support to the idea that the effect of ordering on Tsub(c) is smaller for A-15 compounds composed only of transition metals than those composed of transition and non-transition metals. (author).

291

Plasma source ion implantation of ammonia into electroplated chromium  

Energy Technology Data Exchange (ETDEWEB)

Ammonia gas (NH{sub 3}) has been used as a nitrogen source for plasma source ion implantation processing of electroplated chromium. No evidence was found of increased hydrogen concentrations in the bulk material, implying that ammonia can be used without risking hydrogen embrittlement. The retained nitrogen dose of 2.1 {times} 10{sup 17} N-at/cm{sup 2} is sufficient to increase the surface hardness of electroplated Cr by 24% and decrease the wear rate by a factor of 4.

1995-02-01

292

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

293

Influence of UMTS mobile phone microwave fields on the muscular system; Einfluss von Mikrowellenfeldern des UMTS Mobilfunks auf das muskulaere System  

Energy Technology Data Exchange (ETDEWEB)

Two hypotheses are in the centre of this investigation, on the one hand the question, whether microwaves as exogenous fields alone are able to stimulate human muscle cells above-threshold, and on the other hand, whether microwaves as conditioning to cathodical electrical pulses can modify the excitation threshold and form. No excitation through the application of microwaves alone can be introduced at any subject. The conditioning of above-threshold cathodical electrical pulses with UMTS-microwaves leads not to a transgression of the threshold or the electrical muscle response (EMG) depending on the amplitude, the duration or the dose rate. (orig.)

2004-07-01

294

Effects of avalanche hole injection in fluorinated SiO[sub 2] MOS capacitors  

Energy Technology Data Exchange (ETDEWEB)

Significantly improved immunity to hot-hole damage of the SiO[sub 2]/Si structure is achieved by a shallow fluorine implantation into the poly-Si gate of MOS capacitors followed by a drive-in process. Compared to the nonfluorinated control, the fluorinated samples exhibit a dramatic reduction of both hole trapping probability and interface-trap generation under avalanche hole injection conditions. The degree of such an improvement increases monotonically as a function of the F implantation dose (up to 10[sup 16]/cm[sup 2]). Significant decrease of the hole detrapping rate is also observed in fluorinated samples. Possible mechanisms are discussed.

1993-04-01

295

Demonstration experiment on improved radwaste evaporator  

Energy Technology Data Exchange (ETDEWEB)

High conductivity liquid waste, which is produced in nuclear power plants, is now processed with radwaste evaporator. The concentrated liquid waste in the evaporator is so highly radioactive and corrosive that the improvement on maintenability and reduction of exposure dose rate are desirable as well as high decontamination factor (DF). Fuji Electric constructed the improved experimental facility of evaporator and carried out an experiment to demonstrate DF, maintenability and controllability of system. As the results, DF, maintenability and controllability were proved to be excellent and its applicability to nuclear power plant was well established.

1988-07-01

296

Computer-assisted rotation and multiple stationary irradiation technique  

International Nuclear Information System (INIS)

A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).

297

Complex radiation degradation behaviour of PVC materials under accelerated aging conditions  

International Nuclear Information System (INIS)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).

1982-10-01

298

Complex radiation degradation behavior of PVC materials under accelerated aging conditions  

Energy Technology Data Exchange (ETDEWEB)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.

1983-07-01

299

Accelerated-aging tests for predicting radiation degradation of organic materials  

Energy Technology Data Exchange (ETDEWEB)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-03-01

300

Accelerated-aging tests for predicting radiation degradation of organic materials  

International Nuclear Information System (INIS)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-01-01

301

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results ...

1997-02-01

302

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...

2006-11-15

303

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

International Nuclear Information System (INIS)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...

2006-11-01

304

Pulmonary responses of well-characterized asthmatic, atopic, and normal volunteers to sulfur dioxide; Implications for air quality risk assessment  

Energy Technology Data Exchange (ETDEWEB)

Numerous laboratory investigations have shown that sulfur dioxide (SO/sub 2/) induces bronchoconstriction and respiratory symptoms in exercising asthmatics. These effects appear to depend on dose rate (the product of exposure concentration and ventilation rate), and may occur at dose rates attainable during outdoor exercise in SO/sub 2/-polluted communities. Effects are rapid in onset, requiring no more than 5 min of exercise during exposure. Thus they may be induced by transient elevations of SO/sub 2/ levels, which may occur near large pollution sources even when longer-term average concentrations meet existing air quality standards. Even very mild asthmatics typically are far more sensitive to SO/sub 2/ than healthy volunteers. The authors discuss an investigation designed to expand and improve the dose-response information on SO/sub 2/. In comparison to ...

1987-01-01

305

A case of wound intake of plutonium isotopes and 241Am in a human: application and improvement of the NCRP wound model.  

Science.gov (United States)

Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation Protection and ...

2010-10-01

306

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

Energy Technology Data Exchange (ETDEWEB)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from ...

2007-11-15

307

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

International Nuclear Information System (INIS)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an ...

2007-11-01

308

Zollinger-Ellison syndrome: Presentation, response to therapy, and outcome  

British Library Electronic Table of Contents (United Kingdom)

Background: Recent series describing the clinical presentation, response to therapy, and long-term outcome of Zollinger-Ellison syndrome are limited. Aims: To assess the clinical characteristics and long-term outcome of patients with Zollinger-Ellison syndrome. Methods: Over a 20-year period, patients with Zollinger-Ellison syndrome were enrolled in a prospective trial evaluating the efficacy of lansoprazole. Following dose stabilization, patients were followed on a 6-monthly basis with interval history, physical examination, endoscopy with gastric biopsies, gastric acid analysis and laboratory studies. Results: 72 patients (mean age 54+/-12 years, % male 58%, % Caucasian 69%) were prospectively enrolled. The clinical presentation was stereotypical for Zollinger-Ellison syndrome. Symptoms ...

2011-01-01

309

Pharmacological treatment of primary negative symptoms in schizophrenia: A systematic review  

British Library Electronic Table of Contents (United Kingdom)

BackgroundOptimal treatment of primary negative symptoms is important because their presence is associated with poor outcome.AimsTo systematically review all studies dealing with the efficacy of pharmacological agents on primary negative symptoms.MethodA comprehensive search of the relevant literature was undertaken using electronic database, reference lists and personal contact.ResultsThere is a lack of standardized research designs. Amisulpride is the most extensively studied drug with respect to efficacy against primary negative symptoms. At low doses it demonstrates a consistent, modest effect compared to placebo, though not to conventional antipsychotics and has yet to be tested against other atypicals. Evidence from multiple studies that used simple statistical analyses and inclusion...

2006-01-01

310

Efficacy and safety of a fixed-dose oral combination of pyronaridine-artesunate compared with artemether-lumefantrine in children and adults with uncomplicated Plasmodium falciparum malaria: a randomised non-inferiority trial  

British Library Electronic Table of Contents (United Kingdom)

Summary Background There is a need for new artemisinin-based combination therapies that are convenient, effective, and safe. We compared the efficacy and safety of pyronaridine-artesunate with that of artemether-lumefantrine for treatment of uncomplicated P falciparum malaria. Methods This phase 3, parallel-group, double-blind, randomised, non-inferiority trial was undertaken in seven sites in Africa and three sites in southeast Asia. In a double-dummy design, patients aged 3-60 years with uncomplicated P falciparum malaria were randomly assigned in a 2:1 ratio to receive pyronaridine-artesunate once a day or artemether-lumefantrine twice a day, orally for 3 days, plus respective placebo. Randomisation was done by computer-generated randomisation sequence in blocks of nine by study centre....

2010-01-01

311

Cochrane Review: Polysaccharide vaccines for preventing serogroup A meningococcal meningitis  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground Randomised controlled trials (RCTs) in the 1970s and early 1980s showed the polysaccharide serogroup A vaccine (SgAV) prevented serogroup A meningococcal meningitis (SGAMM). Subsequent non-RCTs suggested significant variations in the age-specific duration of protection among children. Objectives To determine the protective effect, duration of protection, age-specific effects and the effect of booster doses in children of the SgAV against SGAMM. Search strategy We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2010, issue 2) which contains the Acute Respiratory Infections Group's Specialised Register, MEDLINE (January 1950 to May Week 3, 2010) and EMBASE (January 1974 to May 2010). Selection criteria We included RCTs. Non-RCTs ...

2011-01-01

312

Intergalactic dust and its photoelectric heating  

CERN Document Server

We have examined the dust photoelectric heating in the intergalactic medium (IGM). The heating rate in a typical radiation field of the IGM is represented by $\\Gamma_{\\rm pe} = 1.2\\times10^{-34}$ erg s$^{-1}$ cm$^{-3}$ $({\\cal D}/10^{-4})(n_{\\rm H}/10^{-5} {\\rm cm^{-3}})^{4/3} (J_{\\rm L}/10^{-21} {\\rm erg s^{-1} cm^{-2} Hz^{-1} sr^{-1}})^{2/3} (T/10^4 {\\rm K})^{-1/6}$, where ${\\cal D}$ is the dust-to-gas mass ratio, $n_{\\rm H}$ is the hydrogen number density, $J_{\\rm L}$ is the mean intensity at the hydrogen Lyman limit of the background radiation, and $T$ is the gas temperature, if we assume the new X-ray photoelectric yield model by Weingartner et al. (2006) and the dust size distribution in the Milky Way by Mathis, Rumpl, & Nordsieck (1977). This heating rate dominates the HI and HeII photoionization heating rates when the hydrogen number density is less than $\\sim10^{-6}$ cm$^{-3}$ ...

2008-01-01

313

Aerial radiological survey of the Grand Gulf Nuclear Station and surrounding area, Port Gibson, Mississippi. Date of survey: March 1982  

International Nuclear Information System (INIS)

An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure ...

314

Investigation on the state of health (1993-1997) in ambient residents of Daya Bay Nuclear Power Plant in the early days  

International Nuclear Information System (INIS)

Objective: To survey the data for the state of health in the ambient residents of Daya Bay Nuclear Power Plant, and provide the background data to evaluate the state of health affected by fallout of nuclear power plant. Methods: The datas were collected by a radiation epidemiology. The investigation was carried out in the area within 20 km of radius from Daya Bay Nuclear' Power Plant, and the subjects who had lived there for three years or longer before January. 1,1993 and covered by the Household Registry were recruited to a cohort. Results: The mortality rate of overall cancer (per 100 000 PYr) was 88.57 (the standard mortality rate was 79.77 ), the mortality rate of leukemia (per 100 000 PYr) was 3.24 (the standard mortality rate was 2.94), the palpation rate of the goiter in 7-14 years old was 8.34%(9.69% in B ultrasonic), the morbidity ...

2005-06-01

315

Outcome of peripherally inserted central venous catheters in surgical and medical neonates  

British Library Electronic Table of Contents (United Kingdom)

Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...

2011-01-01

316

J/Psi dissociation in parity-odd bubbles  

CERN Document Server

We calculate the quarkonium dissociation rate in the P and CP-odd domains (bubbles) that were possibly created in heavy-ion collisions. In the presence of the magnetic field produced by the valence quarks of colliding ions, parity-odd domains generate electric field. Quarkonium dissociation is the result of quantum tunneling of quark or antiquark through the potential barrier in this electric field. The strength of the electric field in the quarkonium comoving frame depends on the quarkonium velocity with respect to the background magnetic field. We investigate momentum, electric field strength and azimuthal dependence of the dissociation rate. Azimuthal distribution of quarkonia surviving in the electromagnetic field is strongly anisotropic; the form of anisotropy depends on the relation between the electric and magnetic fields and quarkonium momentum. These features can be used to explore the properties of the ...

2011-01-01

317

Effect of Heart Rate on Ventricular Repolarization in Healthy Individuals Applying Vectorcardiographic T Vector and T Vector Loop Analysis  

British Library Electronic Table of Contents (United Kingdom)

Background: Ventricular repolarization (VR) is strongly influenced by heart rate (HR) and autonomic nervous activity, both of which also are important for arrhythmogenesis. Their relative influence on VR is difficult to separate, but might be crucial for understanding while some but not other individuals are at risk for life-threatening arrhythmias at a certain HR. This study was therefore designed to assess the -pure- effect of HR increase by atrial pacing on the ventricular gradient (VG) and other vectorcardiographically (VCG) derived VR parameters during an otherwise unchanged condition. Methods: In 19 patients with structurally normal hearts, a protocol with stepwise increased atrial pacing was performed after successful arrhythmia ablation. Conduction intervals were measured on averag...

2011-01-01

318

A phase II trial of sorafenib in first-line metastatic urothelial cancer: a study of the PMH Phase II Consortium  

British Library Electronic Table of Contents (United Kingdom)

Summary Background Sorafenib is an oral multikinase inhibitor that blocks cell proliferation via the ERK pathway and angiogenesis via the VEGF pathway. This phase II trial was conducted to determine the efficacy and tolerability of sorafenib for the treatment of patients with metastatic urothelial cancer (UC) who had not had prior chemotherapy for advanced disease. Patients and Methods Seventeen chemo-na?ve UC patients with adequate performance status and organ function were treated with sorafenib 400?mg twice daily on a continuous basis until progression or unacceptable toxicity. The primary endpoint was objective tumor response rate as measured by RECIST criteria. Secondary endpoints included rate of prolonged stable disease (>3?months), time to progression, median and 1?yr survival and ...

2011-01-01

319

Pregnancy outcome in women with vitiligo  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background- Vitiligo, characterized by destruction of melanocytes, causes a patchy depigmentation of the skin. It has been hypothesized to have an autoimmune pathogenesis. Autoimmune disorders are more common among women and may be associated with adverse pregnancy outcomes, such as recurrent abortions, intrauterine growth restriction (IUGR), and pre-eclampsia. Objective- The purpose of this study was to investigate whether patients with vitiligo have increased rates of gestational complications. Methods- A retrospective comparative study was undertaken comparing pregnancy complications of patients with and without vitiligo. The population was composed of all singleton deliveries that occurred at the Soroka University Medical Center in Israel during the years 1988-2006. Women lack...

2011-01-01

320

Pair production of charged top-pions in the $\\gamma\\gamma$ collisions at the ILC  

CERN Document Server

The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.

2011-01-01

321

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

322

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents ...

2006-11-13

323

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, ...

2005-11-23

324

Long-term results following multidisciplinary treatment of localized Ewing's sarcoma in children and adolescents  

International Nuclear Information System (INIS)

Purpose: To identify results and prognostic factors on long-term survival and local control following treatment of localized Ewing's sarcoma. Patients and Methods: Between 1979 and 2004, a total of 60 children and young adults with Ewing's sarcoma were treated. Patients with distant metastases at presentation (n = 6) and recurrent cases (n = 2) were excluded from this analysis. Patients were exclusively treated within ongoing national and international protocols CESS-81, CESS-86, EICESS-92, EURO-EWING-99. All patients received local irradiation with a total dose of 45-60 Gy; in addition, 41 (79%) of the patients had local surgical procedures, 27 (52%) of them with clear margins. Results: Overall survival rates at 5 and 10 years were 56% and 45%, respectively. Patients #<=# 14 years at diagnosis had overall survival rates of 66% and 61% at 5 and 10 years compared to older patients with corresponding survival ...

2008-03-01

325

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for {gamma}-ray radiolysis of simulated purex waste solutions  

Energy Technology Data Exchange (ETDEWEB)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of {sup 60}Co {gamma}-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H{sub 2}) = 0.100 d{sup -1.6}. The G-values of oxygen and nitrogen releases were also determined. (author)

1997-12-01

326

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for #gamma#-ray radiolysis of simulated purex waste solutions  

International Nuclear Information System (INIS)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of "6"0Co #gamma#-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H_2) = 0.100 d"-"1"."6. The G-values of oxygen and nitrogen releases were also determined. (author).

1997-01-01

327

Changes in brain development of rat fetus exposed to "1"3"7Cs #gamma# rays in different pregnant periods of the female rats  

International Nuclear Information System (INIS)

Pregnant rats in 11d and 16d of their pregnancy were given one-off whole body exposure by "1"3"7Cs #gamma# rays to 0.2, 0.4, 0.9 and 2.0 Gy, respectively. Changes were observed in conditioned drinking response and cerebrum hippocampi cone cell number of the baby rats exposed to the #gamma# rays in different periods of their embryo development. As a result, that pregnant rats exposed to "1"3"7Cs #gamma# rays in different pregnant periods may induce significant decrease in cerebrum hippocampi cone cell number and achieving rate of conditioned drinking response of the babies. The dose-response relationship can be described by Y=a-b log_1_0D. The achieving rate of conditioned drinking response were significantly correlated to cerebrum hippocampi cone cell number in the babies, and the achieving rate of conditioned drinking response of the babies exposed at pregnant 11d was lower than others exposed at ...

2004-08-01

328

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...

2007-12-15

329

Radiation hardening technologies facing total dose, S.E.U. and S.E.L. in spatial environment  

International Nuclear Information System (INIS)

Space particles act on semiconductor devices by creating charges (electrons, holes) in the silicon and the silicon dioxide, and by creating displacement damage. These primary phenomena alter the electrical parameters of MOS and bipolar devices (threshold voltage V_t, mobility #mu#, conductivity #sigma#, current gain #beta#). The dose rate is not important in space (a few rad (Si)/h) but as the durations of space expeditions are on average from seven to twelve years, the total dose is an aggravating factor in the behaviour of the electrical parameters and also in device operation. The total dose effect from the beginning of charge creation (ionization) to the parameter shifts is reviewed. One can note that this effect is permanent because there will almost always be charge creation in space. Another important phenomenon is called the Single Event Upset (S.E.U.) and caused by the heavy ions and the ...

330

Intensive combined modality therapy including low-dose TBI in high-risk Ewing's sarcoma patients  

International Nuclear Information System (INIS)

Twenty-four high-risk Ewing's sarcoma patients were treated on an intensive combined modality protocol including low-dose fractionated total body irradiaiton (TBI) and autologous bone marrow infusion (ABMI). Twenty patients (83%) achieved a complete clinical response to the primary and/or metastatic sites following induction therapy. The median disease-free interval was 18 months, and nine patients remain disease-free with a follow-up of 22 to 72 months. Local failure as a manifestation of initial relapse occurred in only three patients (15%), each having synchronous distant failure. Eight patients failed initially with only distant metastases, usually within 1-2 years following a complete clinical response. Two patterns of granulocyte recovery following consolidative therapy (including TBI and ABMI) were recognized. The time to platelet recovery was different for the groups with early and late granulocyte recovery. Patients with late recovery did not tolerate ...

331

Evaluation of fungal bio burden and mycotoxins presence in irradiated samples of medicinal plants purchased from wholesale and retail market  

International Nuclear Information System (INIS)

This present study evaluated the effect of gamma radiation on the fungal survival in packed medicinal plants, purchased from wholesale and retail market, in different period (0 and 30 days) after the treatment. Five kind of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia, Paullinia cupana and Cassia angustifolia), were collected from different cities of Sao Paulo State, and submitted to irradiation treatment using a 60Co source (type Gammacell 220) with doses of 5,0 kGy and 10 kGy and at dose rate of 3.0 kGy/h. Non-irradiated samples (control group) were used for fungal counts and serial dilutions from 10-1 to 10-6 of the samples were seeded in duplicates and plated using the surface culture method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. The control group revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi and a ...

2006-12-20

332

Application and evaluation of processing methods of electrochemical noise generated during stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical noise generated during stress corrosion cracking (SCC) of type 304 stainless steel (UNS S30400) and {alpha}-brass were studied. Noise patterns showed common characteristics (i.e., a quick drop and slow recovery of the potential). The quick drop corresponded to the initiation of localized events where fresh metal was exposed. The slow recovery corresponded to the repassivation process of the exposed bare metal. The potential drop rate and recovery rate were almost constant during the SCC process for a given SCC system. For random noise, rates of potential rise and drop were similar. Frequency of the noise generated during SCC increased with an increase in applied stress. SCC initiation could be monitored and determined according to noise characteristics and distribution. Since the shift of background potentials had an obvious influence on characteristics of power spectrum density (PSD), ...

1999-09-01

333

Lung irradiation for Ewing's sarcoma with pulmonary metastases at diagnosis: results of the CESS-studies  

International Nuclear Information System (INIS)

Background: In the German CESS-studies, Ewing's sarcoma patients with pulmonary metastases at diagnosis were considered as candidates for additional bilateral lung irradiation. We have retrospectively analyzed the impact of radiotherapy on survival. Material and methods: Out of 42 patients presenting with pulmonary metastases of Ewing's sarcoma between 1981 and June 1992, 30 were evaluable. One patient died of progressive disease prior to lung irradiation. The other patients had a complete radiographic remission either after chemotherapy (n=25) or chemotherapy plus resection of lung metastases (n=4). 22 patients received bilateral lung irradiation with doses of 12 to 21 Gy (once daily 1.5 Gy or twice daily 1.25 Gy), six had no further treatment and one had bone marrow transplantation for consolidation. Results: Ten patients are in complete remission, nine of them had received lung irradiation and one had a complete resection of three lung ...

334

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water and tritium releases has been performed for Wolsong 2, 3 and 4. CANDU 6 plants continue to perform well in that heavy water ...

1994-03-01

335

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those populations was also ...

1993-08-01

336

Technological physics and special materials: wood-plastic composites obtained by radiation polymerization  

International Nuclear Information System (INIS)

General estimates and references are made in connection with the role of technological physics in obtaining materials with specific features. The first part of the paper presents the modification of weak wood essences as well as technological processes at bench-scale and semi industrial scale of wood-plastic composites, under various irradiation conditions. Two technological installations for the fabrication of wood-plastic composites on both scales with technical and practical specifications of their performances are presented. Experimental data for different wood-plastic composite systems using some local wood essences in combination with several polymer and copolymer systems are given. Impregnation and polymerization levels are mentioned for every specific system. The radiation dose rate and integrated dose are given for every experimental polymerization system. The features of the wood-plastic composites are compared ...

1995-12-02

337

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of ...

1983-01-01

338

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an ...

2000-05-01

339

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed ...

2011-01-15

340

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...

2003-06-01

341

Electrical conductivity of the ceramic AIN under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Aluminum nitride has been proposed as electrically insulating coating in connection with blankets made of vanadium alloys. Irradiations were performed with an applied DC electric field of 100 kV/m, using a 104 MeV {alpha}-particle beam. The dose achieved were 0.1 dpa at 300 C, 0.05 dpa at 400 C, and 0.06 dpa at 500 C. The out-of-beam conductivity {sigma}{sub 0} decreased at all temperatures employed during early stage of irradiation. Before 0.02 dpa had been reached, {sigma}{sub 0} dropped to low values of typically (2-4) x 10{sup -11} ({Omega} m){sup -1}. Although a moderate increase can be observed during further irradiation, {sigma}{sub 0} remained below the initial value of the unirradiated specimen for all temperatures. That is, there is no significant evidence for radiation induced electrical degradation. The in-beam conductivity {sigma}, measured continuously during irradiation, also decreased by at least one order of magnitude. Relevant damage ...

1996-10-01

342

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being ...

343

ESR dating of fault rocks  

Energy Technology Data Exchange (ETDEWEB)

Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs. grain size shows a plateau for grains below critical size; these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Gori nuclear reactor. Most of the ESR signals of fault rocks collected from the basement are saturated. This indicates that the last movement of the faults had occurred before the Quaternary period. However, ...

2003-02-15

344

CoSi_2 nanostructures by writing FIB ion beam synthesis  

International Nuclear Information System (INIS)

A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. ...

2006-07-01

345

Changes in myocardial beta1-adrenergic receptor and stimulatory G-protein gene expression after chronic treatment with doxorubicin in rat.  

Science.gov (United States)

The gene expression of beta(1)-adrenergic receptor (beta(1)AR) and stimulatory G-protein Gsalpha in ventricle after chronic treatment with doxorubicin (DOX) in rat was investigated. The rats were treated with DOX in a dose of 2.5 mg/kg once a week for 5 weeks, the cumulative dose being 12.5 mg/kg. Two weeks after the last injection, the positive inotropic effect of isoproterenol was noticeably decreased in left atrial muscle preparations isolated from DOX-treated rats. Northern blot hybridization showed that the mRNA transcripts of beta(1)AR and Gsalpha, important signal transduction elements for regulating heart rate and contractility, were significantly decreased in the ventricle of DOX-treated rats. Thus, chronic treatment with DOX decreases the gene expression levels of myocardial beta(1)AR and Gsalpha. PMID:15353854

2004-08-01

346

The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months ...

2009-12-01

347

Response Surface Methodology: An Extensive Potential to Optimize in vivo Photodynamic Therapy Conditions  

Science.gov (United States)

Purpose: Photodynamic therapy (PDT) is based on the interaction of a photosensitizing (PS) agent, light, and oxygen. Few new PS agents are being developed to the in vivo stage, partly because of the difficulty in finding the right treatment conditions. Response surface methodology, an empirical modeling approach based on data resulting from a set of designed experiments, was suggested as a rational solution with which to select in vivo PDT conditions by using a new peptide-conjugated PS targeting agent, neuropilin-1. Methods and Materials: A Doehlert experimental design was selected to model effects and interactions of the PS dose, fluence, and fluence rate on the growth of U87 human malignant glioma cell xenografts in nude mice, using a fixed drug-light interval. All experimental results were computed by Nemrod-W software and Matlab. Results: Intrinsic diameter growth rate, a tumor growth parameter independent of the ...

2009-09-01

348

Conservative treatment of choroidal melanomas using iodine brachytherapy; Tratamento conservador ocular dos melanomas de coroide com braquiterapia utilizando placas de Iodo-125  

Energy Technology Data Exchange (ETDEWEB)

Objective: To retrospectively evaluate the results of conservative therapy using escorpal iodine-125 (model 6711, Amershan) plaque for brachytherapy of choroidal melanoma. Materials And Methods: We evaluated 49 patients with choroidal melanoma treated at 'Hospital do Cancer', Sao Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. Results: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy) and 51 to 250 Gy (median: 91 Gy), respectively. The actuarial rates of ocular preservation, disease free survival and ocular preservation in 2-years were 96%, 93.5% and 96.3%, respectively. A ...

2004-08-01

349

Characteristics of transplacental lead transfer in rat dams and fetuses  

International Nuclear Information System (INIS)

This study was designed to quantitate the dose resulting from lead exposure during the critical periods of brain development during gestation by determining: (1) if blood lead concentration in rat dams is affected by pregnancy status or duration of lead exposure, (2) if lead concentration in fetuses is associated with the duration of dam exposure, (3) the rates of lead absorption and elimination in pregnant and nonpregnant dams; and (4) the effect that prebreeding exposure on lead kinetics in the dam and upon fetus blood lead concentrations. The results of experiments in which the dams' drinking water contained 50 mg/L lead indicate blood lead levels (after normalizing by water consumption on a body weight basis) of pregnant rats are significantly higher than blood lead levels of non-pregnant rats. Statistical differences in blood lead levels were observed by day 15 of gestation and continue through day 20 of gestation. These blood lead ...

350

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image ...

2001-03-01

351

effect of gamma rays, fertilization and gibberellin on inter cropped sesame and peanut crops  

International Nuclear Information System (INIS)

This study was undertaken at El-sahafa village, sharkia governorate, during two successive seasons (1988 and 1989) to investigate the effect of four gamma irradiation doses (0,10,20 and 40 Gy), three rates of each of superphosphate (0,100 and 200 Kg/fad.) and gypsum (0,500 and 1000 kg/fad.), as well as, three concentrations of gibberellic acid (0,50 and 100 ppm) on growth, yield and seed quality of solid and inter cropped sesame (Giza 32 cv.) and peanut (Giza 5 cv.) in one inter cropping pattern (3:3). Three separate experiments were carried out where the first one was devoted for gamma irradiation and the second for superphosphate and gypsum fertilization while the third was devoted for gibberellic acid treatment

352

[High-dose thalamonal-rohypnol for premedication. A randomized double-blind study].  

Science.gov (United States)

The combination of fentanyl and droperidol, Innovar, was compared to flunitrazepam (1-2 mg) in a higher dosage (2.5-5 ml) for i.m. premedication. We measured psychological (ESB) and physiological (blood pressure, heart rate, p.cortisol) stress parameters before and after premedication. Side effects were registered. The day after surgery the patients were asked about the quality of premedication. Flunitrazepam reduced anxiety; Innovar did not. After Innovar the feeling of weakness increased significantly compared to flunitrazepam. Two patients panicked and refused operation. Other severe side effects were not observed. There were slight advantages for flunitrazepam on physiological stress. Patients were more satisfied with flunitrazepam than with Innovar premedication. The results show that Innovar also in a higher dosage cannot be recommended for premedication. PMID:6391270

1984-10-01

353

Tracking failure of gamma-ray irradiated polybutylene polymers under magnetic field  

British Library Electronic Table of Contents (United Kingdom)

Polymer insulating materials used in radioactive environments are subjected to a risk of surface degradation caused by tracking. The tracking behavior becomes more complex with the presence of magnetic field. This paper presents investigation of tracking failure of gamma-ray irradiated polybutylene naphthalate (PBN) and polybutylene terephthalate (PBT) under magnetic field. The samples were irradiated in air up to 100 kGy and then up to 1000 kGy with dose rate of 10 kGy/h by using a 60Co gamma-source. Magnetic field Formula Not Shown with flux density of 250 mT was assembled perpendicularly to electric field Formula Not Shown , which gave rise to relative angle between Formula Not Shown and surface normal vector Formula Not Shown of 0degree, 90degree and 180degree, respectively. The experi...

2011-01-01

354

Response to measles-mumps-rubella vaccine in children on dialysis.  

Science.gov (United States)

Ten children receiving maintenance dialysis were immunized with the standard dose of measles-mumps-rubella vaccine between 15 and 33 months of age. Immune responses to vaccination were determined using commercially available enzyme-linked immunosorbent assays for measles, mumps, and rubella viruses. Eight children responded to measles vaccine, 5 to mumps vaccine, 8 to rubella vaccine, and only 3 children to all three vaccines, compared with a seroconversion rate of over 90% to all three vaccines in healthy children (P less than 0.0001). We contend that the relatively poor immunocompetence of our dialysis patients explains their less than optimal vaccine response and suggest that children vaccinated while undergoing dialysis be tested to confirm serological evidence of immunity. PMID:1571219

1992-03-01

355

Radon concentration measurements in bituminous coal mines  

Energy Technology Data Exchange (ETDEWEB)

Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

2005-07-01

356

Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)

2006-11-13

357

Preconcentration and decontamination in radioanalysis  

International Nuclear Information System (INIS)

The scope of radioanalysis can be enlarged substantially by preconcentration. The minimal concentration factor required depends on the concentration to be determined, the limit of determination of the analytical technique and the maximal acceptable sample-weight. Simultaneously, the preconcentration step may cause a decontamination. In post-irradiation chemistry this is usually the crucial parameter. The present paper proposes the classification of (pre-) concentration techniques by the relation between the concentration-factor X and the decontamination-factor Y. In addition, three other criteria here are used to judge the applicability in combination with the analytical technique chosen. They stem from the minimal representative and the maximal acceptable sample-weights and the maximal acceptable dose-rate. The features of a particular combination of (pre-) concentration and analytical technique can be visualized in an X-Y graph. (author).

358

Low-level radioactive waste disposal in the oceans  

Energy Technology Data Exchange (ETDEWEB)

A strategy for the management of the disposal of low-level radioactive wastes into coastal zones and ocean waters has developed over the past three decades. While there has been a substantial increase in the number of international and required agreements there has also been a concomitant improvement in our understanding of the ocean and the processes at work within it. This has allowed more rigorous and reliable assessments to be made of the radiological consequences. With the continued development of basic guidelines of radiological protection by the International Commission on Radiological Protection (ICRP) methodologies have been formulated to derive the fundamental scientific requirement - the relationship between disposal or release rate to the ocean and the resultant radiation dose to exposed human populations.

1983-04-01

359

Kinetic and mass transfer analyses of metal biosorption by Caulerpa lentillifera  

British Library Electronic Table of Contents (United Kingdom)

This study examined kinetics and mass transfer in the biosorption of heavy metals onto Caulerpa lentillifera. The sorption capacity of Cu^2^+, Pb^2^+ and Cd^2^+ from aqueous solution increased with initial metal concentration and decreased with biosorbent dose. Kinetic data were well described using the pseudo-second-order model. Results showed that both external mass transfer and intraparticle diffusion were rate limiting steps in the biosorption process. Activation energy of biosorption kinetics fell in the range of 3-13kJ/mol. The biosorption of Cu^2^+, Cd^2^+ and Pb^2^+ on the biomass correlated well with the Langmuir isotherm (R^2>0.99) with maximum sorption capacities at 293K of 0.169, 0.085 and 0.177mol/kg for Cu^2^+, Cd^2^+ and Pb^2^+ ions, respectively. Thermodynamic studies demon...

2011-01-01

360

Irradiation of Langmuir-Blodgett multilayer preparations of phospholipids and a fatty acid. Pt. 1; Effect of UV radiation  

Energy Technology Data Exchange (ETDEWEB)

Langmuir-Blodgett (LB) preparations containing stacked monolayers of phospholipids or stearic acid were irradiated with UV light and the electric conductance perpendicular to the planes of the monolayers was measured. There was no observable change of conductance when LB preparations of stearic acid were irradiated. For LB preparations of phospholipids, a rise of conductance, dependent on dose rate, was observed, reaching an equilibrium level after a few hours. After irradiation the conductance fell with a temperature-dependent time constant, and eventually reached a final level a little above the initial value. A three-state model is proposed for the LB phospholipid preparations. This suggests that the absorption of one photon raises a molecule from the ground to an excited state; and the absorption of a second photon carries it into a damaged but repairable or metastable state. (author).

1992-12-01

361

Incidence and management of secondary malignancies in patients with retinoblastoma and Ewing's sarcoma  

International Nuclear Information System (INIS)

Childhood cancer survivors at highest risk of developing a secondary malignancy are those with hereditary retinoblastoma. The majority of such secondary cancers will be sarcomas, most commonly of bone. One-third of these occur outside a typical radiation field, commonly in an extremity. Bone sarcoma is also the most commonly reported secondary cancer to develop among survivors of Ewing's sarcoma. In this group, radiation doses greater than 60 Gy as well as alkylating agent chemotherapy have been identified as contributors to the increased risk. The prognosis for patients with a secondary sarcoma has been poor, with few cures reported to date. However, an aggressive, combined modality approach, including radical resection, postoperative radiation, and adjuvant chemotherapy, may improve the survival rate.

362

In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings:  

British Library Electronic Table of Contents (United Kingdom)

Greenman J, Thorn RMS, Saad S, Austin AJ. In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings. Int Wound J 2006;3:322-329. Abstract The aim of this study was to develop an in vitro wound infection model that allows the comparison of the bacterial kill rate of antimicrobial wound dressings over the course of 3 days, with renewed microbial challenges each day, under realistic wound-like conditions. A test bed model of a moderately exuding wound was constructed from a hydrogel containing releasable foetal calf serum (FCS), and cellulose discs dosed with test microbes (Methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) suspended in 50% FCS applied at the interface between the test dressing and the hydrogel test bed. Freshly prep...

2006-01-01

363

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

364

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

365

Growth meachnisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

366

GaAs pattern etching with little damage by a combination of Ga"+focused-ion-beam irradiation and subsequent Cl_2 gas etching  

International Nuclear Information System (INIS)

Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.

367

GaAs pattern etching with little damage by a combination of Ga sup + focused-ion-beam irradiation and subsequent Cl sub 2 gas etching  

Energy Technology Data Exchange (ETDEWEB)

Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.

1990-12-15

368

Focused Ion Beam Induced Effects on MOS Transistor Parameters  

Energy Technology Data Exchange (ETDEWEB)

We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.

1999-07-28

369

Flow-induced changes in pial artery compliance registered with a non-invasive method in rabbits  

British Library Electronic Table of Contents (United Kingdom)

Aim: This study was performed: 1) to assess the relationship between blood flow velocity in the internal carotid artery (CBFICA) and pial artery pulsation (cc-TQ) and 2) to evaluate flow-induced changes in pial artery compliance. Methods: Experiments were performed on 10 crossbred male rabbits. Heart rate (HR), blood pressure (BP), left ventricle ejection fraction (LVEF), CBFICA, the systolic-diastolic blood volume fraction in the brain circulation (CBFSDF) and cc-TQ were recorded after glucagon and acetazolamide administration. cc-TQ was measured with near-infrared transillumination back scattering sounding (NIR-T/BSS), LVEF and CBFSDF with gated scintigraphy and BP and CBFICA with electromagnetic pressure and flow transducers, respectively. Doses of drugs were chosen to exert a haemodyna...

2011-01-01

370

Effect of #gamma#-irradiation on commercial polypropylene based mono and multi-layered retortable food packaging materials  

International Nuclear Information System (INIS)

Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.

2007-07-01

371

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the ...

2006-11-13

372

W, Z and H bosons in the three particle final states production at TeV energy #gamma#e and #gamma##gamma#colliders  

International Nuclear Information System (INIS)

The short review of complete tree level calculations for three particle final states production at the future e"+e"-, #gamma#e and #gamma##gamma# colliders is presented. The results obtained with the help of CompHEP system for total cross sections and other characteristics of processes in the energy range 0.1-2 TeV are summarized and their comparison with the results of different approaches is discussed. In particular we are interested in the processes of W, Z and H boson production. The reactions under consideration are especially interesting in connection with probing of new couplings, searching for new particle signals and as an important backgrounds to these experiments. The main subjects described are basic reactions rates (sections 2,3), Higgs production in #gamma#e collisions (section 4), the possibilities of testing some four vector bosons interaction vertices and Higgs-fermion coupling (section 5), the process of excited neutrino ...

1993-12-01

373

Single charged top-pion production at next generation {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The future e{sup +}e{sup -} linear colliders can also operate in the e{gamma} or {gamma}{gamma} modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process {gamma}{gamma} {yields} tb-bar{pi}{sub t}{sup -}. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode {pi}{sub t}{sup -} {yields} bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in {gamma}{gamma} mode at the TeV energy scale.

2008-09-15

374

Measurement of the static magnetization of solid "3He through the ordering temperature  

International Nuclear Information System (INIS)

The static magnetization of solid "3He contained in sintered copper was measured. The results of the density on the melting curve show that below 5 mK, the magnetization M rises above the Curie-Weiss law extrapolated from high temperature. It reaches a maximum of twice as much as the Curie Weiss law value at temperature Tm, which would be somewhat below 1.25 mK if the system could be warmed up at infinitesimally slow rate. Below Tm, M decreases rapidly to 0.4 of its maximum, then appears to become independent of temperature. The previously reported decrease of specific heat below the Curie-Weiss law value in the range below 4 mK is apparently related to the increase of M in that range. At the low temperature end, apparent decrease of M is due to the fact that there is background magnetization which is out of equilibrium with the thermometer when there is solid "3He in the sample cell. It is suspected that the background ...

1977-09-09

375

Is there an enhancement of muons at sea level from transient events?  

CERN Document Server

In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-ray emission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst ...

2004-01-01

376

Groundwater quality assessment plan for single-shell tank waste management Area U at the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a second part of the ...

2000-03-21

377

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

378

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

379

The reduction of feedwater iron by using absorption characteristics of cation exchange resins for BWR condensate demineralizers  

International Nuclear Information System (INIS)

Iron concentration control in feedwater is one of the most important subjects in water chemistry. Especially for the BWR plants without 100% flow volume of hollow fiber filter (HFF), rather high iron concentration in feedwater is one of the big issues as this causes relatively high radiation dose rate in drywell area. Cation exchange resins especially used in the plants with partial flow rate of HFF are expected to have the important role of capturing iron in feedwater. For this purpose, we have investigated the effective method for using iron absorption characteristics of cation exchange resin. The Cation-Over Layer method (COL) in condensate demineralizers (CD) effectively utilizes these characteristics. In order to demonstrate a performance of the cation overlay method, we had applied this method for three CD vessels at Fukushima Daiichi NPP Unit 3 for testing purpose. The result of this actual plant test indicated that ...

2009-10-01

380

The Study for the Optimal Operation of D{sub 2}O Vapour Recovery System  

Energy Technology Data Exchange (ETDEWEB)

Digital control technology using micro-processor is widely used in Factory Automation area since 1980`s. However, the D{sub 2}O Vapour Recovery System in Wolsung 1 N.P.P is controlled by mechanical timer without considering the moisture condition in the Reactor Building and bed temperature, because it was designed using analog technology of 1960`s. This leads to the inefficient system operation and low D{sub 2}O recovery rate in addition to the high internal dose rate of operator. The goal of this phase II study is to develope a optimal automatic controller of D{sub 2}O vapour recovery system using PLC. We developed a control algorithm for Dual Tower Drier, a PLC control program, a operation change program and the monitoring system with a real-time simulator for system verification. (author). 15 refs., 11 figs., 2 tabs.

1997-12-31

381

Radiation reduction of dicarboxylatoimidazole platinum(II) complexes in the water-methanol system  

Energy Technology Data Exchange (ETDEWEB)

The radiation reduction of bis(1-ethylimidazole)tartratoplatinum(II) (EITPt(II)) complexes in methanol-water solution have been examined. The yields of Pt(I) depend on the presence of O{sub 2} in solutions as well as the dose applied. The rate constants of e{sub s}{sup -} scavenging by EITPt(II) and cis(diammine-1,1-cyclobutanedicarboxylato) platinum(II) (CBDCAPt(II)) have been determined by pulse radiolysis to be equal to 5.4 x 10{sup 9} and 6.4 x 10{sup 9} M{sup -1} s{sup -1}, respectively. The efficiencies of e{sub t}{sup -} scavenging by EITPt(II) and the rate of e{sub t}{sup -} photobleaching have also been determined in LiCl : H{sub 2}O : CH{sub 3}OH and MgCl{sub 2} : H{sub 2}O : CH{sub 3}OH glasses, respectively. (author).

1997-10-01

382

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

383

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

384

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors ...

2001-09-01

385

A Two-step Intensity-modulated Radiation Therapy Method for Nasopharyngeal Cancer: The Kinki University Experience  

British Library Electronic Table of Contents (United Kingdom)

Objective The aim of this study was to analyze the clinical results of our adaptive radiation therapy scheme of a two-step intensity-modulated radiotherapy (IMRT) method for nasopharyngeal cancer (NPC) at Kinki University Hospital. Methods Between 2000 and 2007, 35 patients with Stage I-IVB NPC treated by IMRT were included. For all patients, treatment-planning computed tomography was done twice before and during IMRT to a total dose of 60-70 Gy/28-35 fractions (median 68 Gy). Chemotherapy (cisplatin 80 mg/m2/3 weeks x 1-3 courses) was given concurrently with IMRT for 31 patients. Results The 3- and 5-year overall survival rates for the 31 patients treated with concurrent chemotherapy were 88% and 83%, respectively. The 3- and 5-year loco-regional control rates for the 31 patients were 93%...

2010-01-01

386

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

388

Simultaneous Liver-Kidney Versus Liver Transplantation Alone in Patients with End-Stage Liver Disease and Kidney Dysfunction Not on Dialysis  

British Library Electronic Table of Contents (United Kingdom)

BackgroundSince implementation of the Model for End-stage Liver Disease (MELD), the number of simultaneous liver-kidney transplantations (SLKT) has increased in the United States. However, predictors and survival benefit of SLKT compared to liver transplantation alone (LTA) are not well defined. MethodsOrgan Procurement and Transplantation Network data of patients with end-stage liver disease (ESLD) with estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2 who had not been on dialysis while on the waiting list and underwent liver transplantation between 2002 and 2008 were analyzed. To identify predictors of undergoing SLKT versus LTA, multiple logistic regression analysis was performed. Cox proportional hazards regression analysis was used to assess the association between...

2011-01-01

389

On Essential Incompleteness of Hertz's Experiments on Propagation of Electromagnetic Interactions  

CERN Document Server

The historical background of the 19th century electromagnetic theory is revisited from the standpoint of the opposition between alternative approaches in respect to the problem of interactions. The 19th century electrodynamics became the battle-field of a paramount importance to test existing conceptions of interactions. Hertz's experiments were designed to bring a solid experimental evidence in favor of one of them. The modern scientific method applied to analyze Hertz's experimental approach as well as the analysis of his laboratory notes, dairy and private letters show that Hertz's "\\textit{crucial}" experiments cannot be considered as conclusive at many points as it is generally implied. We found that alternative Helmholtz's electrodynamics did not contradict any of Hertz's experimental observations of transverse components as Maxwell's theory predicted. Moreover, as we now know from recently published Hertz's dairy and private notes, his first experimental ...

2005-01-01

390

Mesenchymal stem cell transplantation for diffuse alveolar hemorrhage in SLE  

British Library Electronic Table of Contents (United Kingdom)

Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...

2010-01-01

391

Materials aspects of multijunction solar cells  

Energy Technology Data Exchange (ETDEWEB)

Atomic layer epitaxy (ALE) was used to grow several components of the cascade solar cell structure in the AlGaAs/GaAs system. An ALE reactor was constructed for multiwafer growth with a growth rate of 0.6 {mu}m h{sup -1}. Device quality GaAs and Al{sub x}Ga{sub 1-x}As films were grown with p-type background carbon doping in the ranges 10{sup 16}-10{sup 19} cm{sup -3} and 10{sup 16}-10{sup 20} cm{sup -3} respectively. N-type films were achieved by SiH{sub 4} doping, producing carrier concentrations in the range 10{sup 16}-10{sup 18} cm{sup -3}. In addition, the potential applications of the ALE technique in the photovoltaic field are discussed. (orig.).

1991-05-01

392

Information-seeking behaviour and coping style of women opting for either implant or DIEP-flap breast reconstruction  

British Library Electronic Table of Contents (United Kingdom)

Background: High satisfaction rates have been reported after autologous breast reconstruction. Yet, most mastectomy patients receive implant reconstructions (ImBR). Independent and active decision makers have shown mainly to choose for autologous reconstructions, such as the Deep inferior epigastric perforator (DIEP) flap (DiepBR). To further explore the decision making to opt for either ImBR or DiepBR, we investigated patient knowledge, informational resources used, effect of plastic surgeons' advice, coping style and personal independence. Methods: A total of 153 women, who were planned for DiepBR or ImBR preoperatively, completed a study-specific and standardised validated psychological questionnaire. Analyses were aimed at information-seeking behaviour, personal independence and coping...

2011-01-01

393

Improving surgical outcome following the Norwood procedure  

British Library Electronic Table of Contents (United Kingdom)

Background The Norwood procedure consists of three palliative operations, performed in neonates with hypoplastic left heart syndrome. Especially the first stage (Norwood I) is associated with the highest mortality rates in paediatric cardiac surgery (up to 25%). During surgery, the aorta is reconstructed and a systemic-to-pulmonary shunt is applied. Originally the modified Blalock-Taussig shunt was used, but recently the right-ventricle-to-pulmonary-artery shunt is increasingly being employed. We reviewed the results of our operative strategy, where an individualised choice of shunt is made. Furthermore, attempts to reduce interstage mortality (between Norwood I and II) were assessed. Methods All neonates who underwent Norwood stage I palliation from August 2004 until November 2010 were in...

2011-01-01

394

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

395

Endoscopic monitoring of infliximab therapy in Crohn's disease  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground: So far, infliximab (IFX) therapy for the treatment of Crohn's disease (CD) has generally been guided by clinical symptoms. Data on treatment response as ascertained by endoscopy in IFX therapy are scarce. The aims of this study were to measure the endoscopic response rate during IFX induction and maintenance therapy in luminal CD, and also evaluate the role of endoscopy in monitoring IFX therapy. Methods: Data obtained from 71 patients with active luminal CD and treated with IFX were analyzed retrospectively. The endoscopy findings were scored according to mucosal activity as: 0 (remission), 1-2 (mild), 3-4 (moderate), and 5-6 (severe). A positive endoscopic response was determined by a decrease in score of at least two points and mucosal healing was assigned a score of...

2011-01-01

396

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.

2011-02-01

397

Design and operating parameters for emission control studies: Asarco, Tacoma, copper smelter. Final task report, Apr--Oct 1975  

Science.gov (United States)

The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. Portions of this document are not fully legible. (GRA)

1976-02-01

398

Design and operating parameters for emission control studies: Asarco, Hayden, copper smelter. Final task report, Apr--Oct 1975  

Science.gov (United States)

The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. (GRA)

1976-02-01

399

D-branes in a big bang/big crunch universe: Misner space  

Energy Technology Data Exchange (ETDEWEB)

We study D-branes in a two-dimensional lorentzian orbifold R{sup 1,1}/{gamma} with a discrete boost {gamma}. This space is known as Misner or Milne space, and includes big crunch/big bang singularity. In this space, there are D0-branes in spiral orbits and D1-branes with or without flux on them. In particular, we observe imaginary parts of partition functions, and interpret them as the rates of open string pair creation for D0-branes and emission of winding closed strings for D1-branes. These phenomena occur due to the time-dependence of the background. Open string 2{yields}2 scattering amplitude on a D1-brane is also computed and found to be less singular than closed string case.

2005-09-01

400

Cosmological Information from Lensed CMB Power Spectra  

CERN Document Server

Gravitational lensing distorts the cosmic microwave background (CMB) temperature and polarization fields and encodes valuable information on distances and growth rates at intermediate redshifts into the lensed power spectra. The non-Gaussian bandpower covariance induced by the lenses is negligible to l=2000 for all but the B polarization field where it increases the net variance by up to a factor of 10 and favors an observing strategy with 3 times more area than if it were Gaussian. To quantify the cosmological information, we introduce two lensing observables, characterizing nearly all of the information, which simplify the study of non-Gaussian impact, parameter degeneracies, dark energy models, and complementarity with other cosmological probes. Information on the intermediate redshift parameters rapidly becomes limited by constraints on the cold dark matter density and initial amplitude of fluctuations as observations improve. Extraction of ...

2006-01-01

401

A Comparison of POSSUM and GPS Models in the Prediction of Post-operative Outcome in Patients Undergoing Oesophago-gastric Cancer Resection  

British Library Electronic Table of Contents (United Kingdom)

Background There is some evidence that a patient?s pre-operative condition influences short-term and long-term post-operative outcomes. The aim of the present study is to compare the physiological and operative severity score for the enumeration of mortality and morbidity (POSSUM) and modified Glasgow prognostic score (mGPS) models in the prediction of post-operative outcome, both short term and long term, in patients undergoing resection of oesophago-gastric cancer. Patients and Methods Patients who underwent curative resection for oesophago-gastric cancer from January 2005 to May 2009 and who had data to score the POSSUM, P-POSSUM, O-POSSUM and mGPS models were included in the study. Observed morbidity and mortality rates were compared with predicted outcome in different risk groups. Bot...

2011-01-01

402

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

403

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

404

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background ...

2009-05-01

405

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the ...

1992-10-25

406

Murine respiratory mycoplasmosis (MRM) in C57BL/6N and C3H/HeN mice: strain differences in early host responses and exacerbation by nitrogen dioxide  

Energy Technology Data Exchange (ETDEWEB)

The studies reported here used genetic differences in susceptibility of C57BL/6N and C3H/HeN mice and exacerbation of the disease by nitrogen dioxide (NO/sub 2/) as tools in assessing the role of early host responses in the pathogenesis of MRM. The two strains did not differ in susceptibility to infection, but C3H/HeN mice were more susceptible to and had increased severity of lung lesions 14 days after intranasal inoculation as determined by 50% biological endpoints and morphometric analysis of tissues. Exposure to NO/sub 2/ for 4 hours prior to exposure to infectious aerosols exacerbated murine respiratory mycoplasmosis (MRM) by 7 days after exposure in both mouse strains. NO/sub 2/ appeared to affect host lung defense mechanisms responsible for limiting mycoplasmal growth in the lungs. The NO/sub 2/ exposure concentration required for this effect varied with the genetic background of the host, the dose of mycoplasmas administered, and the ...

1987-01-01

407

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to detect a real ...

2007-08-21

408

Experimental attempt to produce mRNA transfected dendritic cells derived from enriched CD34+ blood progenitor cells  

British Library Electronic Table of Contents (United Kingdom)

It Peripheral blood progenitor enriched CD34+ cells (PBPC) are rather often used as stem cell background in cancer patients following high dose therapy. Keeping in mind that precursor dendritic cells (DCs) originate from haematopoietic progenitor cells, purified CD34+ cells might also serve as starting cells for ex-vivo production of DC. The aim of the present study is to develop a clinical grade procedure for ex-vivo production of DC derived from enriched CD34+ cells. Various concentrations of CD34+ cells were grown in gas-permeable Teflon bags with different serum-free and serum-containing media supplemented with GM-CSF, IL-4, TNF-a, SCF, Flt-3L and INF-a. Serum-free CellGroSCGM medium for 7 days followed by CellGroDC medium in 7 days gave equal results as serum-containing medium. Follow...

2008-01-01

409

A magnetically levitated electrode ionization chamber of the noncontact measurement type  

Energy Technology Data Exchange (ETDEWEB)

A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the {gamma}-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum ...

2002-04-01

410

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or ...

1995-07-01

411

Role of radiation therapy in the management of nonmetastatic Ewing's sarcoma of bone. Report of the intergroup Ewing's sarcoma study  

International Nuclear Information System (INIS)

The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local ...

412

Effect of systemic blockade of ?(1)-noradrenergic receptors on sex behavior and vaginal-cervical stimulation-induced Fos in female rats.  

Science.gov (United States)

It is hypothesized that systemic ??-noradrenergic antagonists may interfere with the transmission of sensory stimulation, particularly vaginal--cervical stimulation (VCS), which is crucial for reproductive functioning. To determine if ??-noradrenergic transmission receptor activity is necessary for transmission of sensory information important for VCS-dependent events, we conducted an experiment using prazosin, a ??-noradrenergic receptor antagonist. First, three doses of prazosin (1.0, 0.5 or 0.1 mg/kg) or the 10% ETOH in sesame oil vehicle were administered i.p. and sexual receptivity was assessed 30 min later in ovariectomized, hormone-treated female rats. The 1 mg/kg dose of prazosin significantly inhibited lordosis quotients and lordosis ratings. This dose of prazosin (1.0 mg/kg) was then administered 30 min prior to VCS or control scapular stimulation (CSS) and Fos-IR was examined in the ...

2010-10-01

413

Development of recombinant adeno-associated virus and adenovirus cocktail system for efficient hTERTC27 polypeptide-mediated cancer gene therapy.  

Science.gov (United States)

The low in vivo transduction efficiency of recombinant adeno-associated virus (rAAV) and the undesirably strong immunogenicity of adenovirus (rAdv) have limited their clinical utilization in cancer gene therapy. We have previously demonstrated that intratumoral injection of rAAV expressing a C-terminal polypeptide of human telomerase reverse transcriptase (rAAV-hTERTC27) effectively inhibits the growth of glioblastoma xenografts in nude mice. To further improve its efficacy, we combined rAAV-hTERTC27 with rAdv and investigated the efficiency of the cocktail vectors in vivo. At a nontherapeutic dose (1 x 10(8) plaque-forming units (PFUs)), rAdv-null and rAdv-hTERTC27 were equipotent in enhancing the therapeutic efficacy of rAAV-hTERTC27 (1.5 x 10(11) v.g.), and complete tumor regression was achieved in 25% of the treated animals. Importantly, the combination of rAAV-hTERTC27 and a therapeutic dose (2.5 x 10(9) PFU) of rAdv-hTERTC27 significantly ...

2008-06-06

414

Comparative tissue distribution and excretion of orally administered ["3H]diacetoxyscirpenol (anguidine) in rats and mice  

International Nuclear Information System (INIS)

A quantitative comparison of tissue distribution and excretion of an orally administered sublethal dose of [3H]diacetoxyscirpenol (anguidine) was made in rats and mice 90 min, 24 hr, and 7 days after treatment. Total recoveries of 95-100% were obtained. Approximately 90% of the dose was excreted in urine and feces during the first 24 hr with a feces:urine ratio of about 1:4.5 in both species. Carcass and tissue radioactivity dropped rapidly during the first 24 hr but remained relatively constant at low, but detectable, levels over the course of the experiment. Few substantive interspecies differences were noted in tissue distribution. At 90 min the highest percentage of dose was in tissues involved in sequestering diacetoxyscirpenol because of high body water/lipid content or the absorption, metabolism, or excretion of the toxin. The rank order of these tissues was generally stable over the course of the experiment. When ...

415

Status report about the revision of an IEC standard for personal dose equivalent meters for H{sub p}(10) and H{sub p}(0,07); Statusbericht ueber die Neufassung einer IEC-Norm fuer H{sub p}(10)- und H{sub p}(0,07)-Personendosimeter  

Energy Technology Data Exchange (ETDEWEB)

A working group (SC 45B/WG B8) exists within the international electrochemical commission (IEC) which is working on the combination and revision of the IEC standards 61283, 61323, 61344, 61525 and 61526. All these standards concern direct reading, electronic, personal dose equivalent meters for the quantities H{sub p}(10) and H{sub p}(0,07); they are different with regard to the kind of radiation (photons, and/or beta rays and/or neutrons). The new standard with the number 61526 shall cover the following topics: 1. Combination of all the mentioned standards; 2. Maintenance of the essential requirements of the former standards; 3. Inclusion of the determination of the uncertainty of measurement for the measured dose equivalent value according to the ''Guide to the Expression of Uncertainty in Measurement''; 4. Consideration of all the relevant ISO-standards for reference radiation fields for photon, beta and ...

2001-07-01

416

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ...

2006-07-01

417

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum values obtained were 0.29 pCi/l of Sr-90 in ...

1981-12-01

418

A lysimeter study of nitrate leaching, optimum fertilisation rate and growth responses of corn (Zea mays L.) following soil amendment with water-saving super-absorbent polymer  

British Library Electronic Table of Contents (United Kingdom)

Abstract BACKGROUND: Nitrate leaching and the resulting groundwater contamination from intensive cereal production has become a major concern for long-term farmland efficiency and environmental sustainability in northern China. The aim of this study was to evaluate a water-saving super-absorbent polymer (SAP) for minimising NO3- leaching from soil and optimising corn growth and yield. Thirty-six undisturbed soil lysimeters were installed in a field lysimeter facility in drought-affected northern China to study the growth and yield characteristics of summer corn (Zea mays L.) as well as the amount of NO3-leaching losses under different fertiliser (standard, medium or 75% and low, or 50% of conventional fertilisation rate) and SAP (control, 0; level-1, 15 kg ha-1 and level-2, 30 kg ha-1) tre...

2011-01-01

419

A Precision Measurement of the Neutrino Mixing Angle theta_13 using Reactor Antineutrinos at Daya Bay  

CERN Document Server

A reactor-neutrino experiment, Daya Bay, has been proposed to determine the least-known neutrino mixing angle theta_13 using electron antineutrinos produced at the Daya Bay nuclear power complex in China. Daya Bay is an international collaboration with institutions from China, the United States, the Czech Republic, Hong Kong, Russia, and Taiwan. The experiment will use eight identical detectors deployed at three different locations optimized for monitoring the antineutrino rates from the six reactors and for detecting any rate deficit and spectral distortion near the first oscillation maximum. The overburden of the under ground experimental halls, connected with tunnels, ranges from about 250 to 900 meters-water-equivalent so that the cosmogenic background is small compared to the number of observed antineutrino events. Civil construction of tunnels and experimental facilities is planned to start in 2007, with detector ...

2007-01-01

420

Population kinetics studies in mouse jejunum exposed prenatally to gamma rays at different dose rates  

International Nuclear Information System (INIS)

Pregnant Swiss albino mice of 18 days post conception were exposed to 0.80 Gy, 0.40 Gy and 0.20 Gy of gamma rays from a Cobalt-60 source at different dose rates (.0584 Gy/min and .00091 Gy/min). Post irradiation variations in the cell population of crypts and villus of jejunum were studied in the F_1-generation at 1 day, 3 day and 1,2,4,6 and 12 weeks of post-partum age. In all the exposure groups at 1 day post-partum age, crypts show a decrease in total cells, mitotic figures and goblet cells on one hand and an increase in PNNC on the other hand in comparison to coeval controls. At this interval a decrease in the number of total cells as well as goblet cells/villus column was also noticeable. Dead cells which were prominently seen in crypts were totally absent in villi. The first signs of recovery can be observed on day 3 p.p. when total cell population, mitotic activity and goblet cells of crypt registered an increase while percentage of PNNC ...

2001-02-20

421

Effect of repeated benzene inhalation exposures on benzene metabolism, binding to hemoglobin, and induction of micronuclei  

International Nuclear Information System (INIS)

Metabolism of benzene is thought to be necessary to produce the toxic effects, including carcinogenicity, associated with benzene exposure. To extrapolate from the results of rodent studies to potential health risks in man, one must know how benzene metabolism is affected by species, dose, dose rate, and repeated versus single exposures. The purpose of our studies was to determine the effect of repeated inhalation exposures on the metabolism of [14C]benzene by rodents. Benzene metabolism was assessed by characterizing and quantitating urinary metabolites, and by quantitating 14C bound to hemoglobin and micronuclei induction. F344/N rats and B6C3F1 mice were exposed, nose-only, to 600 ppm benzene or to air (control) for 6 hr/day, 5 days/week for 3 weeks. On the last day, both benzene-pretreated and control animals were exposed to 600 ppm, 14C-labeled benzene for 6 hr. Individual benzene metabolites in urine collected for 24 ...

422

The effects of cosmic radiation on implantable medical devices  

Energy Technology Data Exchange (ETDEWEB)

Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to ...

1996-12-31

423

Concurrent Chemoradiotherapy in Resected Extrahepatic Cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: Extrahepatic cholangiocarcinoma is a rare malignancy. Despite radical resection, survival remains poor, with high rates of local and distant failure. To clarify the role of radiotherapy with chemotherapy, we performed a retrospective analysis of resected patients who had undergone chemoradiotherapy. Methods and Materials: A total of 45 patients (13 with proximal and 32 with distal disease) underwent resection plus radiotherapy (median dose, 50.4 Gy). All but 1 patient received concurrent fluoropyrimidine-based chemotherapy. The median follow-up was 30 months for all patients and 40 months for survivors. Results: Of the 45 patients, 33 underwent adjuvant radiotherapy, and 12 were treated neoadjuvantly. The 5-year actuarial overall survival, disease-free survival, metastasis-free survival, and locoregional control rates were 33%, 37%, 42%, and 78%, respectively. The median survival was 34 months. No patient died ...

2009-01-01

424

Characterization and wear tests of steel surfaces implanted with oxygen, aluminum, and carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

A number of screening tests were performed to determine ion species that effectively reduce wear rates when implanted in four industrial steels. Ball bearing steel 100Cr6 (AISI 52100) showed a wear rate reduction by a factor of 20 when implanted with carbon dioxide to a dose of 5x10{sup 17} cm{sup -2} with a non-mass-separated ion beam and by a factor of {>=}20 when implanted with 5x10{sup 17} cm{sup -2} oxygen ions. For the ferritic and martensite steels X90CrMoV18 (AISI 440B, unhardened and hardened) also a strong wear reduction after implantation of oxygen ions was found. Co-implantation of aluminum and oxygen also reduces wear rates of X90CrMoV18, of S6-5-2 (AISI M2), and of 100Cr6, respectively. For comparison, thin oxide layers were grown in a low-temperature thermal oxidation process. These experiments also yielded reduced wear rates by a factor of 10. The surfaces were ...

1991-07-01

425

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial substitution of [InS_2]- anion radical by [FeSe_2] there have been ...

2003-09-15

426

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...

2008-11-19

429

Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine  

International Nuclear Information System (INIS)

In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in Tarqumia secondary girls ...

430

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the lowest ...

2007-06-05

431

ICPES analyses using full image spectra and astronomical data fitting algorithms to provide diagnostic and result information  

Energy Technology Data Exchange (ETDEWEB)

ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of ...

1997-10-01

432

Synthesis of polyester styrene resin beads as polymeric ionic exchangers by using chemical and irradiation techniques  

International Nuclear Information System (INIS)

The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling ...

3087-01-01

433

Groundwater flow analysis and dose rate estimates from releases to wells at a coastal site  

Energy Technology Data Exchange (ETDEWEB)

In the groundwater flow modelling part of this work the effective dilution volume in the well scenario was estimated by means of transient simulations of groundwater flow and transport, which are coupled due to the varying salinity. Both deep, drilled wells and shallow surface wells in the vicinity of the repository were considered. The simulations covered the time period from the present to 1000 years after the present. Conceptually the fractured bedrock consists of planar fracture zones (with a high fracture density and a greater ability to conduct water) and the intact rock (in which the fracture density and the hydraulic conductivity are low). For them the equivalent-continuum model was applied separately. Thus, the fractured bedrock was considered as piecewise homogeneous (except for the depth dependence) and isotropic continuum with representative average characteristics. A generic simulation model for groundwater flow and solute transport was developed on the basis of ...

2000-09-01

434

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...

2008-08-01

435

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

1981-06-01

436

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

437

Absorbed dose and dose reduction in mammography  

International Nuclear Information System (INIS)

First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).

1986-01-01

438

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

439

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

440

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

441

The influence of modified water chemistries on metal oxide films, activity build-up and stress corrosion cracking of structural materials in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within ...

1999-03-01

442

Non-seminomatous testicular germ cell tumours. Preliminary analysis of ongoing trials in the DATECA study  

Energy Technology Data Exchange (ETDEWEB)

This report deals with the preliminary results of trials in the DATECA project with stage I, II and III patients with non-seminomatous germ cell tumours. Stage 1 patients were randomized between infradiaphragmatic irradiation and observation. No significant difference in recurrence rates has been observed as yet. Eighteen of 95 patients had recurrence with a median time to relapse of 3 months. Fifteen patients achieved complete remission after treatment by combination chemotherapy while 3 patients are still undergoing treatment. Stage II patients received 6 series of cis-platinum, bleomycin, and vinblastine. The patients were initially randomized to receive chemotherapy alone versus chemotherapy plus irradiation. Irradiation led to increased toxicity and decreased doses of the antineoplastic drugs. Fifty-one patients were studied. The overall complete remission rate was 89 per cent including 7 patients who achieved complete ...

1984-01-01

443

Non-seminomatous testicular germ cell tumours  

International Nuclear Information System (INIS)

This report deals with the preliminary results of trials in the DATECA project with stage I, II and III patients with non-seminomatous germ cell tumours. Stage 1 patients were randomized between infradiaphragmatic irradiation and observation. No significant difference in recurrence rates has been observed as yet. Eighteen of 95 patients had recurrence with a median time to relapse of 3 months. Fifteen patients achieved complete remission after treatment by combiantion chemotherapy while 3 patients are still undergoing treatment. Stage II patients received 6 series of cis-platinum, bleomycin, and vinblastine. The patients were initially randomized to receive chemotherapy alone versus chemotherapy plus irradiation. Irradiation led to increased toxicity and decreased doses of the antineoplastic drugs. Fifty-one patients were studied. The overall complete remission rate was 89 per cent including 7 patients who achieved complete ...

1984-01-01

444

Decontamination of the reactor coolant pump in Maanshan nuclear power plant  

International Nuclear Information System (INIS)

To reduce the radiation dose that accumulated on the reactor coolant pump, decontamination work was carried out at the Maanshan Nuclear Power Plant. A four-step alkaline permanganate (AP)-CanDecon process was applied to remove the activity on the turning vane diffuser and pump impeller. The first step consisted of 8 h of AP treatment and 7 h of decontamination. It was followed by 2.5 h of AP treatment and 5 h of decontamination. An average decontamination factor of 2.9 was obtained. To understand the corrosion of the decontaminating reagents on the materials, coupons were installed in the decontamination tank. These were as-received and sensitized 304SS, alloy 600, casting stainless steel (CF-8), stellite-6, and carbon steels (A508 and A533). The exposure rates (mR h"-"1) of the carbon steels were approximately five times higher in magnitude than those of the other materials. The decontamination levels (dpm per 100 cm"2) of the A508 and A533 ...

445

High-dose radiation therapy for inoperable non-small cell lung cancer without mediastinal involvement (clinical stage N0, N1)  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of radiation therapy alternative to surgery for clinical N0-N1 non-small cell lung cancer (NSCLC). From 1976 through 1989, 116 patients with NSCLC without mediastinal involvement were treated with definitive radiation therapy alone at Gunma University Hospital. All patients were treated with once-daily standard fractionation using 10 MV X-rays. The total dose ranged from 60 Gy to 80 Gy. The actuarial 2- and 5-year survival rates of the entire group were 43% and 20%, respectively with a median survival time of 19 months. The survival of 76 patients with stage T2 tumors was significantly better than that of 28 patients with T3 tumors (mean survival time 21 versus 15.5 months; p<0.05). Sixty-two patients with tumors less than 5 cm in diameter had a 2-year progression rate of 20%, in comparison with 39% of 54 patients with tumors greater than 5 cm. The difference of survivals for these 2 groups was ...

1996-09-01

446

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...

1989-08-15

447

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

448

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

449

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

450

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...

2001-04-01

451

Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.  

UK PubMed Central (United Kingdom)

Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available

1982-03-01

452

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

453

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

454

A two-stage sequential linear programming approach to IMRT dose optimization  

UK PubMed Central (United Kingdom)

The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available

2010-02-07

455

Risk of leukaemia following intravenous treatment with {sup 224}Ra - results of a long term follow-up study of ankylosing spondylitis patients; Leukaemierisiko nach intravenoeser {sup 224}Ra-Behandlung - Ergebnisse einer Langzeitstudie an Bechterew-Patienten  

Energy Technology Data Exchange (ETDEWEB)

In an epidemiological study of the somatic late effects risk following incorporation of a short lived {alpha}-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of {sup 224}Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 {mu}Ci) of {sup 224}Ra each, given at weekly intervals; this would result in an cumulative {alpha}-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases ...

1993-12-31

456

Photoelectrocatalytic degradation of organic pollutants with TiO{sub 2} electrodes  

Energy Technology Data Exchange (ETDEWEB)

Photoelectrochemical oxidation is a potentially interesting method for destroying toxic organic materials. We have studied the photoelectrocatalytic activity of TiO{sub 2} films made by thermal oxidation of titanium, low pressure chemical vapour deposition (LPCVD), and anodisation of titanium. Two model organic compounds have been investigated for photooxidation: methyl phosphonic acid (MPA) which is a nerve gas analogue and 4-chlorophenol (4-CP) which is a chlorinated aromatic compound considered a standard for the evaluation of the TiO{sub 2} / UV processes. In addition to photoelectrochemical characterisation the films have been characterised by profilometry, XRD, AFM, photocurrent spectroscopy and Raman microscopy. Correlations have been made between the physical properties of the thin films and their catalytic activities. The most catalytic sample of thermally oxidised titanium was prepared at 400 deg C, and the presence of anatase was shown by XRD, MPA degradation test and ...

2001-07-01

457

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

458

Investigation of Nuclide Importance to Functional Requirements Related to Transport and Long-Term Storage of LWR Spent Fuel  

Energy Technology Data Exchange (ETDEWEB)

The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the evolution of some 1600 ...

1995-01-01

459

On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery  

UK PubMed Central (United Kingdom)

The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available

2008-09-21

460

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

461

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...

462

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation decay time. We have confirmed that it enables ...

1999-07-01

463

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider ...

2000-05-01

464

Structural and functional responses of benthic invertebrates to imidacloprid in outdoor stream mesocosms  

International Nuclear Information System (INIS)

Structural and functional responses of a benthic macroinvertebrate assemblage to pulses of the insecticide imidacloprid were assessed in outdoor stream mesocosms. Imidacloprid pulses reduced invertebrate abundance and community diversity in imidacloprid-dosed streams compared to control streams. These results correlated well with effects of imidacloprid on leaf litter decomposition and feeding rates of Pteronarcys comstocki, a stonefly, in artificial streams. Reductions in oxygen consumption of stoneflies exposed to imidacloprid were also observed in laboratory experiments. Our findings suggest that leaf litter degradation and single species responses can be sensitive ecotoxicological endpoints that can be used as early warning indicators and biomonitoring tools for pesticide contamination. The data generated illustrates the value of mesocosm experiments in environmental assessment and how the consideration of functional and structural ...

465

Shielding analysis of TAPP-3,4 end-shield  

International Nuclear Information System (INIS)

This paper consists of shielding analysis of steel balls and water filled end shields of Indian Pressurized Heavy Water Reactors (PHWRs). The material composition inside lattice tube is entirely different neutronically as compared with the composition of end-shield. Due to variation of material composition in radial and axial directions and complex geometry, it is necessary to carry out 3-D analysis for reasonable prediction of neutron flux and gamma dose rates. In the present paper, shielding analysis of end-shield for 540 MWe PHWR has been carried out during reactor operating and shutdown conditions using Monte-Carlo code MCNP. Furthermore materials on the periphery and central portion of end shield are different. Therefore the analysis was carried out separately for annular portion and central portion of end shield. The dominating streaming paths through end shields were studied. Predictions compare well with the measurements at TAPS-4 ...

2006-11-13

466

Ruthenium-106 brachytherapy for uveal melanomas. Preliminary results: a single institutional experience; Braquiterapia com rutenio-106 em melanomas uveais. Resultados preliminares: experiencia uni-instuticional  

Energy Technology Data Exchange (ETDEWEB)

Objective: To analyze the early response of uveal melanomas in patients treated with ruthenium-106 brachytherapy. Materials And Methods: In the period between April 2002 and July 2003, 20 patients diagnosed with uveal melanoma were submitted to ruthenium-106 brachytherapy. The calculated dose delivered at the apex of the tumor ranged between 55 Gy and 100 Gy. Patients with lesions greater than 5 mm were submitted to transpupillary thermotherapy concomitantly with ophthalmic plaque insertion. Results: As regards the lesions site, 75% of the lesions were located in the choroid, 15% in the iris, and the remainder 10% in the ciliary body. In a median 19-month-follow-up, the progression-free survival for brachytherapy was 69%, and 87% for associated brachytherapy and transpupillary thermotherapy. A significant tumor height reduction was observed after treatment. No patient was submitted to enucleation. Conclusion: Our preliminary results show that ruthenium-106 ...

2007-03-15

467

Radiological follow-up of the environment of the G.I.P. CYCERON of Caen - year 2005 - 2006 - assessment 2007; Suivi radiologique de l'environnement des installations du GIP CYCERON de Caen - annee 2005 - 2006 - bilan 2007  

Energy Technology Data Exchange (ETDEWEB)

The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows to make sure that the G.I.P. operator ...

2007-07-01

468

Prediction of monitoring data for 239Pu accidentally injected via wound site based on the proposed NCRP wound model.  

Science.gov (United States)

In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The committed doses in the ...

2007-06-07

469

Neutronic aspects of the safety and environmental performance of silicon carbide as blanket structural material  

Energy Technology Data Exchange (ETDEWEB)

Safety and environmental assessments have been made of conceptual fusion power plant designs employing silicon carbide composites (SiC/SiC) as the first wall and blanket structure material. These have used similar analysis methods to earlier studies of designs based on vanadium alloy or low-activation martensitic steel, allowing direct comparisons. The very low short-term activation of silicon carbide results in an almost insignificant level of decay heat in postulated loss of coolant accidents, and a lower {gamma}-dose rate on the timescale of relevance to handling for maintenance operations. However on the longer time-scale, of interest in possible recycling operations, decommissioning and waste management, SiC/SiC appears to perform no better than vanadium alloy or low-activation martensitic steel, due in part to the activation of impurities in a realistic composition. Furthermore, its increased neutron transparency may result in higher ...

2001-04-01

470

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -I. 6. Neutronics Analyses for Beamline Upgrades to the High Flux Isotope Reactor  

International Nuclear Information System (INIS)

The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...

2001-06-17

471

Long-term effects of prenatal x-ray of human females: reproductive experience  

Energy Technology Data Exchange (ETDEWEB)

A cohort of singleton black human females exposed to diagnostic x-ray in utero and controls matched by parity, hospital of birth and birthdate have been followed to ages 25 to 30 years in Baltimore, Maryland. The search for possible effects of prenatal irradiation has focused on health, growth, development, and reproductive experience of exposed and control women. This paper reports findings related to reproductive experience. From an original data set of 1458 matched exposed-control pairs of women, questionnaire responses were received from 1109 exposed and 1124 control women including 852 each from pairs in which both the exposed and control woman responded. After careful search for alternative explanations of the findings, the authors concluded that females exposed in utero to low doses of x-ray (probably 1 to 5 rads) had significant increases in their rates of early onset of menses, births at age 15 years or less, numbers of living ...

1981-09-01

472

Localized deformation and IASCC initiation in austenitic stainless steels  

International Nuclear Information System (INIS)

Localized deformation may play a key role in the underlying mechanism of irradiation assisted stress corrosion cracking (IASCC) in light water reactor core components. In this study, four austenitic alloys, 18Cr8Ni, 15Cr12Ni, 13Cr15Ni and 21Cr32Ni, with different stacking fault energies were irradiated to 1 and 5 dpa at 360 deg. C using 3.2 MeV protons. Interrupted constant extension rate tensile (CERT) tests were conducted in a simulated BWR environment to determine IASCC susceptibility. In order to characterize the localized deformation in slip channels and grain boundaries, parallel CERT experiments were also performed in an argon atmosphere. Results show that the IASCC susceptibility of the tested alloys increases with increasing irradiation dose and decreasing stacking fault energy. IASCC tends to initiate at locations where slip channels intersect grain boundaries. Localized deformation in the form of grain boundary sliding due to the ...

2008-12-01

473

Ligands for the peroxisome proliferator-activated receptor-#gamma# have inhibitory effects on growth of human neuroblastoma cells in vitro  

International Nuclear Information System (INIS)

The thiazolidinedione (TZD) or glitazone class of peroxisome proliferator-activated-#gamma# (PPAR-#gamma#) ligands not only induce adipocyte differentiation and increase insulin sensitivity, but also exert growth inhibitory effects on several carcinoma cell lines in vitro as well as in vivo. In the current study the in vitro effect of four PPAR-#gamma# agonists (ciglitazone, pioglitazone, troglitazone, rosiglitazone) on the cell growth of seven human neuroblastoma cell lines (Kelly, LAN-1, LAN-5, LS, IMR-32, SK-N-SH, SH-SY5Y) was investigated. Growth rates were assessed by a colorimetric XTT-based assay kit. Expression of PPAR-#gamma# protein was examined by immunohistochemistry and Western blot analysis. All glitazones inhibited in vitro growth and viability of the human neuroblastoma cell lines in a dose-dependent manner showing considerable effects only at high concentrations (10 #mu#M and 100 #mu#M). Effectiveness of the glitazones on ...

2005-09-15

474

Implementation of the NCRP wound model for interpretation of bioassay data for intake of radionuclides through contaminated wounds.  

Science.gov (United States)

Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and daily urinary or faecal excretion rate of ...

2009-05-01

475

Hydrogen behavior in the iron surface layer modified by plasma nitriding and ion boronising  

Energy Technology Data Exchange (ETDEWEB)

The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...

2000-12-01

476

Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958  

Energy Technology Data Exchange (ETDEWEB)

In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one ...

1985-12-01

477

Heterogeneous radiolysis of HCN adsorbed on a solid surface  

International Nuclear Information System (INIS)

Hydrogen cyanide is a key molecule for chemical evolution studies because, when it is exposed to different sources of energy, it forms various compounds of biological importance. To understand the role of minerals in chemical evolution, a series of experiments was performed. First, the adsorption capacity of HCN on different surface minerals was studied; the results show that HCN is readily adsorbed onto the solids proposed (zeolite, serpentine, dolomite, and sodium montmorillonite), in particular zeolite and montmorillonite. Second, the radiolysis of HCN adsorbed on olivine (as an example of a mineral surface) was also followed; it was found that the rate of HCN decomposition by gamma irradiation is enhanced in the presence of the solid. The third series of studies show that organic material was produced in high abundance from HCN at high radiation doses. The radiolytic products included gases (CO_2, NH_4, and CO) and oligomeric materials that ...

2010-07-01

478

Genotoxic effects of sunlight-activated waste waters  

Energy Technology Data Exchange (ETDEWEB)

Natural sunlight induces a genotoxic response in cultured CHO cells pre-treated with shale oil retort process water. Near ultraviolet light (NUV) component of the solar spectrum is the apparent radiation responsible for photoactivation. Cultured human skin fibroblasts are acutely sensitive to the genotoxic effects of photoactivated process water. The mutagenic potential of photoactivated process water in human cells is the same as that witnessed for an equivalent killing dose of the potent skin carcinogen FUV. DNA repair processes are involved in modulating genotoxic effects of this photo-induced process. The exact magnitude of the potential health-related and environmental risks resulting from photoactivation of retort process waters and other oil shale by-products is unassessed at this time. Our demonstration that a significant rate of mutation occurs in cultured human cells exposed to high dilutions of process waters and fluences of NUV ...

1981-01-01

479

Final report of the specific research. Investigations on the analysis of bio-protective factors against radiation. 1998-2000 FY (Research Group of NIRS)  

Energy Technology Data Exchange (ETDEWEB)

This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of radiation-sensitive genes. The groups describe summaries of their studies and published original articles are also ...

2002-03-01

480

Experimental determination of the dosimetric characteristics for the I-Plant"T"M model 3600 "1"2"5I brachytherapy source  

International Nuclear Information System (INIS)

The dosimetric characteristics for a new brachytherapy seed source (I-Plant"T"M model 3600) were measured using LiF thermoluminescent dosimeters and appropriate phantom materials in conformance with the methodology and guidance provided by the AAPM Task Group 43. The I-Plant"T"M model 3600 is the successor to the I-Plant"T"M model 3500. The major difference between these sources is that the model 3600 contains a leaded-glass core to provide radio-opacity (while the model 3500 contains a silver core), which does not produce spectral contamination upon neutron activation. The dose rate constant #LAMBDA# for the model 3600 was determined to be 1.00 Gy h"-"1 U"-"1 (with a 6% overall relative standard deviation), compared to 1.01 cGy h"-"1 U"-"1 reported for the model 3500 in previous studies. The remaining dosimetric characteristics also are similar for both sources.

2005-06-01

481

Evaluation of antioxidant and anti-atherogenic properties of Glycyrrhiza glabra root using in vitro models.  

Science.gov (United States)

The aim of present study was to evaluate antioxidant property of Glycyrrhiza glabra root extracts using in vitro models. The dose-dependent aqueous and ethanolic extracts demonstrated the scavenging activity against nitric oxide (concentration that caused 50% inhibition of nitric oxide radicals [IC(50)]=72 and 62.1 microg/ml, respectively), superoxide (IC(50)=64.2 and 38.4 microg/ml, respectively), hydroxyl (IC(50)=81.9 and 63 microg/ml, respectively), DPPH (IC(50)=43.6 and 28.3 microg/ml, respectively) and ABTS(*+) (IC(50)=77.3 and 57.2 microg/ml, respectively) radicals. Further, both extracts showed strong reducing power and iron-chelating capacities. In the Fe(2+)/ascorbate system, both extracts were found to inhibit mitochondrial fraction lipid peroxidation. In copper-catalyzed human serum and low-density lipoprotein oxidation models, both extracts significantly (P<0.05) lengthened the lag phase along with a decline in the oxidation ...

2009-04-22

482

Environmental pollutant isotope measurements and natural radioactivity assessment for North Tushki area, south western desert, Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that ...

2002-09-01

483

Enhanced cadmium cytotoxicity in A549 cells with reduced glutathione levels is due to neither enhanced cadmium accumulation nor reduced metallothionein synthesis  

International Nuclear Information System (INIS)

Glutathione (GSH) depletion sensitizes human lung carcinoma (A549-T27) cells to the cytotoxic effects of Cd++. The effects of GSH depletion on Cd++ accumulation and Cd++-induced metallothionein (MT) content were investigated to determine the possible role of these Cd++ responses in the sensitization process. Cellular GSH was depleted to 20% to 25% of control levels with buthionine sulfoximine (BSO), or diethyl maleate (DEM), respectively. Neither treatment significantly affected Cd++-induced accumulation of exogenous 35s-cysteine into intracellular MT in a dose-dependent fashion. The results indicate that neither enhanced Cd++ accumulation nor reduced MT synthesis plays a primary role in affecting enhanced Cd++ cytotoxicity in A549 cells with reduced GSH levels. Although BSO inhibition of GSH synthesis enhanced MT synthesis, it sensitized the cells to Cd++, which suggests an additive effect of GSH and MT in cadmium cytoprotection. This observation also raises the ...

484

Effects of interstitial clustering on transient enhanced diffusion of boron in silicon  

Energy Technology Data Exchange (ETDEWEB)

A simulation model for boron diffusion which takes into account the aggregation of the excess interstitials in clusters, and subsequently, the dissolution of these defects, is proposed. The interstitial supersaturation and generation rate are determined according to the classical theory of nucleation and growth of particles, in analogy with the precipitation of a new phase in heavily doped silicon. The clusters are considered as precipitates formed by interstitial Si atoms. The B diffusion is modelled on the basis of the dopant-interstitial pair diffusion mechanism. The clusters dissolution during annealing maintains nearly constant, for a long period, the interstitial supersaturation and the related enhancement of the boron diffusion. This gives a good account of the diffusion results over a large range of experimental conditions. Furthermore, this approach describes most of the behavior of the transient enhanced diffusion (TED), like the temperature dependence of ...

1997-11-01

485

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-07-01

486

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-05-10

487

Corrosion behaviour of molybdenum-implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...

1990-01-01

488

Corrosion behaviour of molybdenum-implanted stainless steel  

International Nuclear Information System (INIS)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...

1989-09-01

489

Comparison of beam-induced deposition using ion microprobe  

International Nuclear Information System (INIS)

The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced compared with that by FIB processing. The ...

1999-01-02

490

Biosorption of cadmium(II), zinc(II) and lead(II) by Penicillium simplicissimum: Isotherms, kinetics and thermodynamics  

Energy Technology Data Exchange (ETDEWEB)

The isotherms, kinetics and thermodynamics of Cd(II), Zn(II) and Pb(II) biosorption by Penicillium simplicissimum were investigated in a batch system. The effects of pH, initial metal ions concentration, biomass dose, contact time, temperature and co-ions on the biosorption were studied. Adsorption data were well described by both the Redlich-Peterson and Langmuir model. Chemical ion-exchange was found to be an important process based on free energy value from Dubini-Radushkevich isotherm for all metal ions. The results of the kinetic studies of all metal ions at different temperature showed that the rate of adsorption followed the pseudo second-order kinetics well. The thermodynamics constants {delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o} of the adsorption process showed that biosorption of Cd(II), Zn(II) and Pb(II) ions on Penicillium simplicissimum were endothermic and spontaneous.

2008-12-30

491

Benzyl carbamyl analogue of lignocaine: vasodepressor mechanism of action.  

Science.gov (United States)

1. The benzyl carbamyl analogue of lignocaine [2-(diethylaminoacetamido)-3-carbamyl-4-methyl-5-benzylpyrrole] at an intravenous dose of 4 mg/kg caused a blood pressure decrease of 54 mmHg. 2. A greater hypotensive effect was observed in hypertensive compared to normotensive animals. Anaesthesia magnified the vasodepressor effect in both groups. 3. The analogue did not possess centrally-mediated effects on blood pressure but exerted its hypotensive effect via a peripheral mechanism. 4. The analogue produced a relaxant effect on intestinal and vascular smooth muscle while exerting minimal effects on muscarinic, sympathetic, or ganglionic nicotinic receptors. 5. The analogue exhibited less cardiac depressant action on left ventricular rate (dp/dt) and force of contraction than lignocaine. 6. Lethal effects for the analogue were first observed at 16 mg/kg following intravenous administration and at 500 mg/kg following intraperitoneal ...

492

A proposal for prevention of acute radiation hazard and social panic regarding orphan sources in Japan  

International Nuclear Information System (INIS)

To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a categorization of orphan sources according to dose rates to deal with unknown sources in a scrap yard. Our report ...

2002-10-20

493

Surface modification of PTFE sheet by synchrotron radiation in the soft X-ray region  

International Nuclear Information System (INIS)

Full text: The surface properties of poly (tetrafluoroethylene) (PTFE) are changed by the exposure to synchrotron radiation (SR). We succeeded in controlling the wettability of the PTFE surface from hydrophobic to hydrophilic by varying the substrate temperature during the SR irradiation and found that the wettability was ascribable to microstructure and chemical composition of surface.In these previous works, oxygen atoms were found to inhabit on the hydrophobic surface of PTFE. In this study, we investigated the surface modification of PTFE from the SR exposure experiment under the O_2 gas atmosphere. The SR exposure to the PTFE sheet was carried out at beamline 6 (BL6) of the New- SUBARU. The PTFE sheet was irradiated to the white beam, ranging 50-1000 eV at BL6 at room temperature. The gas cell was mounted at the irradiation chamber. The O_2 gas pressure in the gas cell can be maintained at about 0.20 Pa during the SR exposure using 5mm #phi# hole window. The wettability of PTFE ...

2004-07-19

494

Simulations of Groundwater Flow and Radionuclide Transport in the Vadose and Saturated Zones beneath Area G, Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Numerical simulations are used to predict the migration of radionuclides from the disposal units at Material Disposal Area G through the vadose zone and into the main aquifer in support of a radiological performance assessment and composite analysis for the site. The calculations are performed with the finite element code, FEHM. The transport of nuclides through the vadose zone is computed using a three-dimensional model that describes the complex mesa top geology of the site. The model incorporates the positions and inventories of thirty-four disposal pits and four shaft fields located at Area G as well as those of proposed future pits and shafts. Only three nuclides, C-14, Tc-99, and I-129, proved to be of concern for the groundwater pathway over a 10,000-year period. The spatial and temporal flux of these three nuclides from the vadose zone is applied as a source term for the three-dimensional saturated zone model of the main aquifer that underlies the site. The movement of these ...

1999-07-01

495

Evaluation of synergistic effect in vacuum pack, refrigeration and irradiated treatments of minimally processed cassava; Avaliacao do efeito sinergistico da embalagem a vacuo, irradiacao e refrigeracao da mandioca minimamente processada  

Energy Technology Data Exchange (ETDEWEB)

Cassava is cultivated almost all over the world and it is considered one of the most important nutritious sources of calories in the human diet. Cassava is a viable food against starvation in several poor areas of the world because it is an extremely resistant culture and may reach satisfactory economical yield. We utilized vacuum packed industrialized cassava irradiated with 0,1 kGy, 3kGy and 5kGy and stored under refrigeration for 1, 21, 30 and 50 days. Our objective was to analyse the synergistic effect of vacuum packing, irradiation and refrigeration on the preservation of minimally processed cassava. The samples were analyzed for pH, acidity, weight, humidity, texture and color. The irradiation did not affect the chemical characteristics of the cassava. Neither the pH nor the acidity, the most relevant variables to verify deterioration in cassava, presented significant alterations during the period of storage. Comparing the irradiated treatments, the dose of ...

2005-07-01

496

Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience  

International Nuclear Information System (INIS)

Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the ...

2009-09-01

497

Development of a system model for the postclosure assessment of a concept for geological disposal of Canada`s nuclear fuel waste  

Energy Technology Data Exchange (ETDEWEB)

Atomic Energy of Canada has recently submitted for regulatory and public review an Environmental Impact Statement (EIS) on a concept for disposal of Canada`s nuclear fuel waste. The EIS is supported by nine primary references that summarize major aspects of the concept, including a postclosure environmental and safety assessment. The scope of the postclosure assessment is largely determined by the requirements of the Atomic Energy Control Board (AECB) of Canada. These requirements include a quantitative estimate of the annual effective dose equivalent to an individual in the most exposed group of people (the critical group) for 10,000 years following closure of the disposal facility, and a radiological risk criterion with an associated dose rate limit of 0.05 mSv/a. Over this long time frame, a quantitative assessment cannot be based on actual observations, and thus we use scientific arguments and simulations with ...

1995-12-01