WorldWideScience

Sample records for axial tomography evidence

  1. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  2. Development of axial tomography technique for the study of steam explosion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, S. W.; You, S. [Handong Golbal Univ., Pohang (Korea, Republic of)

    2006-05-15

    In this report, axial tomography applying to steam explosion is implemented. When steam explosion experiment is performed, we have seen the difficulty with physical modeling due to the complex phenomena of generated steam, propagation of shock wave and bubble breakup and coalescence. Hence, the uncertainty due to these phenomena is occurred. The fast and global measurement of the steam distribution is imperative to understand the complex phenomena performed during the steam explosion, KAERI have developed the fast and global measuring instrument to monitor such phenomena of axial steam distribution. Generally, X-ray is used as measuring method, but this method is very expensive and has limited measurement area. So we need new method that can substitute X-ray method and in this research, ECT method is replaced. The research is performed dividing within two parts: Software and Hardware. In the software part, the electric field analysis code and algorithm for inverse projection were developed. And, in the hardware part, capacitance measurement circuit is developed to measure up to fF level. Operable axial tomography was analyzed with concept design of axial tomography appropriate to steam explosion accident and analysis code for axial electric field analysis and inverse algorithm were developed, moreover, designing signal analysis system for axial tomography was performed.

  3. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  4. Axial tomography

    International Nuclear Information System (INIS)

    Brueckner, K.A.; Lewis, J.H.

    1979-01-01

    The invention relates to axial tomography, sometimes referred to as cross-sectional x-ray. The apparatus described may utilize the conventional x-ray or ultrasonic source and detector and scanning mechanism for producing the plurality of sets of radiation detector output signals. It has the means for storing the detector output signals in analog form with the signals of one set overlying the signals of another set so that signals resulting from radiation through a zone of the object being examined are summed at a corresponding zone in the storage device, typically an electronic storage tube. The summed signals are read from the storage device with a radially inversely proportional reader producing a second signal for storage, again typically in an electronic storage tube. These signals stored in the second storage device are read with Laplacian relation, with the resultant sigal being a video signal that may be connected to a TV monitor for display of the sectional image. In alternative embodiments, optical film systems and electrostatic systems are utilized. (JTA)

  5. Computerized axial tomography in traumatic cervical lesions

    International Nuclear Information System (INIS)

    Koyama, Tsunemaro

    1982-01-01

    Although plain computerized axial tomography cannot routinely demonstrate the spinal cord, it does provide excellent visualization of the bony outline of the spinal canal and vertebral column. So it should be reasonable to use this technique in cases of cervical traumatic disorders. In this paper we presented 10 cases of cervical traumatic lesions; 3 atlanto-axial dislocation, 2 cervical canal stenosis, 3 OPLL, 1 intramedullary hematoma and 1 C 2 -neurinoma. In some patients neurologic deficits were induced by cervical trauma. Bony lesions appeared more adequately deliniated than intraspinal lesions, however, in some cases intramedullary changes could also be demonstrated. The use of metrizamide with high resolution CT-scanner could improve the usefullness of this technique. (author)

  6. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  7. Target localization on standard axial images in computed tomography (CT) stereotaxis for functional neurosurgery - a technical note

    International Nuclear Information System (INIS)

    Patil, A.-A.

    1986-01-01

    A simple technique for marking functional neurosurgery target on computed tomography (CT) axial image is described. This permits the use of standard axial image for computed tomography (CT) stereotaxis in functional neurosurgery. (Author)

  8. Axial tomography in 3D live cell microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Piper, Mathis; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-07-01

    A miniaturized setup for sample rotation on a microscope stage has been developed, combined with light sheet, confocal or structured illumination microscopy and applied to living cells as well as to small organisms. This setup permits axial tomography with improved visualization of single cells or small cell clusters as well as an enhanced effective 3D resolution upon sample rotation.

  9. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  10. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  11. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  12. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  13. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    Schmidt, M.

    1989-01-01

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  14. Axial tomography in live cell laser microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-09-01

    Single cell microscopy in a three-dimensional (3-D) environment is reported. Cells are grown in an agarose culture gel, located within microcapillaries and observed from different sides after adaptation of an innovative device for sample rotation. Thus, z-stacks can be recorded by confocal microscopy in different directions and used for illustration in 3-D. This gives additional information, since cells or organelles that appear superimposed in one direction, may be well resolved in another one. The method is tested and validated with single cells expressing a membrane or a mitochondrially associated green fluorescent protein, or cells accumulating fluorescent quantum dots. In addition, axial tomography supports measurements of cellular uptake and distribution of the anticancer drug doxorubicin in the nucleus (2 to 6 h after incubation) or the cytoplasm (24 h). This paper discusses that upon cell rotation an enhanced optical resolution in lateral direction compared to axial direction can be utilized to obtain an improved effective 3-D resolution, which represents an important step toward super-resolution microscopy of living cells.

  15. Subclinical coronary atherosclerosis by multi-scan axial tomography and its association with hyperglycemia

    International Nuclear Information System (INIS)

    Buchaca Faxas, Emilio F; Bencomo Rodriguez, Llimia; Bermudez Rojas, Sergio

    2010-01-01

    A study was conducted to assess the usefulness of multi-scan axial tomography techniques to detect, in a subclinical stage, the coronary damage in patients presenting with diabetes mellitus (DM) to describe the frequency of asymptomatic atherosclerotic affection and its potential association with the fasting and postprandial hyperglycemia. In study were included 59 patients with type 2 diabetes to compare the results of coronary calcium determination with the findings of angiography by multi-scan axial computed tomography (CAT-M). There was a concordance of a 44.1% between both studies, as well as a predominance of soft plaques in the 55.9 % of patients. The 42.4 % showed a narrowing of arterial lumen, which was significant in the 16.5 % of total. A high figure of patients with hyperglycemia had coronary damage compared to those ills with a good glycemia control (p = 0.024). This relation was more evident with the postprandial hyperglycemia (= 0.016). Hyperglycemia had a high opportunity (5.99 times) to detect coronary lesions by TAC-C compared to other major atherosclerosis risk factors like the high blood pressure, smoking, dyslipemias expressed in a significant way (p 0.045). We conclude that Angio TAC-C and Calcio Score techniques are useful to detect lesions of coronary arteries in patients with type 2 diabetes mellitus without symptoms of myocardial ischemia, which was associated to presence of a hyperglycemia, fundamentally postprandial

  16. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  17. Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography

    International Nuclear Information System (INIS)

    Russell, E.J.; Koslow, M.; Lasjaunias, P.; Bergeron, R.T.; Chase, N.

    1982-01-01

    Anatomical relationships of temporal bone structures are demonstrated by thin section edge detection computed tomography. Many otic structures are best appreciated in axial view, but reorientation to anatomy as seen in this plane is needed for optimal diagnosis. A level by level review of key structure is presented toward this end. The limitations and advantages of computed tomography are discussed. (orig.)

  18. Image reconstruction. Application to transverse axial tomography

    International Nuclear Information System (INIS)

    Aubry, Florent.

    1977-09-01

    A method of computerized tridimensional image reconstruction from their projection, especially in the computerized transverse axial tomography is suggested. First, the different techniques actually developped and presented in the literature are analyzed. Then, the equipment used is briefly described. The reconstruction algorithm developped is presented. This algorithm is based on the convolution method, well adapted to the real conditions of exploitation. It is an extension of SHEPP and LOGAN's algorithm. A correction of the self absorption and of the detector's response is proposed. Finally, the first results obtained which are satisfactory are given. The simplicity of the method which does not need a too long computation time makes possible the implementation of the algorithm on a mini-computer [fr

  19. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  20. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  1. Tomografía axial computarizada en pacientes con enfermedades cerebrovasculares hemorrágicas Computerized axial tomography in patients with hemorrhagic cerebrovascular diseases

    Directory of Open Access Journals (Sweden)

    Solángel Bolaños Vaillant

    2009-10-01

    Full Text Available Se efectuó un estudio descriptivo y transversal de 196 pacientes con enfermedad cerebrovascular hemorrágica, que abarcó desde enero del 2004 hasta igual mes del 2005 en el Hospital Provincial Docente “Saturnino Lora” de Santiago de Cuba, a los cuales se indicó una tomografía axial computarizada. Al relacionar las imágenes tomográficas con los síntomas y signos presentados por los enfermos, se halló lenguaje tropeloso en todos ellos; predominio de hematomas intraparenquimatosos, generalmente en ganglios basales y región temporal, así como primacía de la hipertensión arterial entre los antecedentes patológicos más importantes. Se concluyó que la tomografía axial computarizada es un medio para diagnóstico certero en las urgencias médicas por esa grave afección.A descriptive and cross sectional study of 196 patients with cerebrovascular hemorrhagic disease was carried out from January, 2004 to the same month of 2005 in "Saturnino Lora" Teaching Provincial Hospital from Santiago de Cuba, to whom a computerized axial tomography was indicated. When relating the tomographic images with the symptoms and signs which they presented, trouble speaking was detected in all of them; prevalence of intraparenchymatous hematomas, generally in basal ganglia and temporal region, as well as prevalence of hypertension among the most important pathological history. It was concluded that computarized axial tomography is a mean for precise diagnosis in medical emergencies due to that serious disorder.

  2. Axial positrons emission tomography: from mouse to human brain imaging

    International Nuclear Information System (INIS)

    Brard, Emmanuel

    2013-01-01

    Positrons emission tomography is a nuclear imaging technics using nuclear decays. It is used both in clinical and preclinical studies. The later requires the use of small animals such as the mouse. The objective is to obtain the best signal with the best spatial resolution. Yet, a weight ratio between humans and mice indicates the need of a sub-millimeter resolution. A conventional scanner is based on detection modules surrounding the object to image and arranged perpendicularly. This implies a strong relationship between efficiency and spatial resolution. This work focuses on the axial geometry in which detection modules are arranged parallel to the object. This limits the relationship between the figures of merit, leading to both high spatial resolution and efficiency. The simulations of prototypes showed great perspectives in term of sub-millimeter resolution with efficiencies of 15 or 40% according to the scanner's axial extension. These results indicate great perspectives for both clinical and preclinical imaging. (author)

  3. Computerized axial tomography and diagnosis of multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Paulo R.M. Bittencourt

    1983-06-01

    Full Text Available Computed axial tomography (C.T. findings are illustrated in 3 patients who presented with C.T. changes suggesting respectively chronic M.S., acute M.S., and an appearance simulating a malignant tumour. Review of the literature shows that the chronic form with cerebral atrophy and low density lesions in the hemispheres is common in patients with a long history and is unlikely to cause diagnostic difficulty. The acute presentation is less common and could be confused with a variety of causes of multiple low density enhancing lesions. The C.T. diagnosis of M.S. is more difficult in rare cases in which plaques cause mass effect and show ring enhancement; all 3 such cases in the literature were subjected to cerebral biopsy.

  4. Computerized axial tomography in the detection of brain damage

    International Nuclear Information System (INIS)

    Cala, L.A.; Mastaglia, F.L.

    1980-01-01

    The cranial computerized axial tomography (CAT) findings in groups of patients with epilepsy, migraine, hypertension, and other general medical disorders have been reviewed to assess the frequency and patterns of focal and diffuse brain damage. In addition to demonstrating focal lesions in a proportion of patients with seizures and in patients presenting with a stroke, the CAT scan showed a premature degree of cerebral atrophy in an appreciable proportion of patients with long-standing epilepsy, hypertension and diabetes, and in some patients with migraine, valvular and ischaemic heart disease, chronic obstructive airways disease, and chronic renal failure. The value of CAT as a means of screening for brain damage in groups of individuals at risk is discussed

  5. A study of the imaging of atomic elements by computerised axial tomography

    OpenAIRE

    McCarthy, K. J

    1989-01-01

    Conventional computerized axial tomography images show the spatial variation in the linear attenuation coefficient in a cross-section of a specimen. However, no information is present to enable one to predict the location nor concentration of an atomic element in the image. Differential X-ray absorptiometry is a well established analytic technique for determining the concentration of an atomic element in a specimen. In this thesis, it is shown that by applying differential X-ray absorpt...

  6. Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops

    Science.gov (United States)

    Bradu, Adrian; Jackson, David A.; Podoleanu, Adrian

    2018-03-01

    Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (Ascans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the recirculation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an "in-house" swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range.

  7. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  8. Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.

    Science.gov (United States)

    Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F

    1980-01-01

    Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.

  9. Study of the human encephalon morphology by computerized axial tomography in neurological diseases

    International Nuclear Information System (INIS)

    Loynaz Fernandez, Clara Silvia; Milan Companioni, Daile; Gomez Padron, Ivo; Alvarez Leon, Oladys; Espinosa Quiros, Desiderio

    2001-01-01

    Since the middle of the last century, the study of the human encephalon morphology has been of great interest for the researchers. With the introduction of the computerized axial tomography in 1974, it was possible to expand the knowledge about this area and at the same time provide information on the structural lesions that are pathologies of great psychosocial repercussion like epilepsy and Parkinsonism. This paper used 90 tomographic studies on people aged 20-80 years. A series of linear measurements were made and statistically processed. The results showed variations in linear measurements among control, epileptic and Parkinsonian subjects

  10. A method for volume determination of the orbit and its contents by high resolution axial tomography and quantitative digital image analysis.

    Science.gov (United States)

    Cooper, W C

    1985-01-01

    The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment.

  11. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  12. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  13. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  14. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    Rodriguez Cheong, Maricel; Dosouto Infante, Vivian; Rosales Fargie, Yamile

    2010-01-01

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  15. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  16. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  17. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    International Nuclear Information System (INIS)

    Sondheimer, H.M.; Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-01-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease

  18. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    Classically, myopathies are categorized according to limb or cranial nerve muscle affection, but with the growing use of magnetic resonance imaging it has become evident that many well-known myopathies have significant involvement of the axial musculature. New disease entities with selective axial...

  19. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  20. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    International Nuclear Information System (INIS)

    Dugas, Alexandre; Therasse, Éric; Kauffmann, Claude; Tang, An; Elkouri, Stephane; Nozza, Anna; Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles

    2012-01-01

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001–0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662–0.780) and single-plane MPR images (0.772–0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  1. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, P., E-mail: peter.andersson@physics.uu.se; Andersson-Sunden, E.; Sjöstrand, H.; Jacobsson-Svärd, S. [Department of Physics and Astronomy, Division of Applied Nuclear Physics, Uppsala University, Lägerhyddsgatan 1, 751 20 Uppsala (Sweden)

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  2. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator.

    Science.gov (United States)

    Andersson, P; Andersson-Sunden, E; Sjöstrand, H; Jacobsson-Svärd, S

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm(-1), solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  3. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    International Nuclear Information System (INIS)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.

    2015-01-01

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length

  4. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

    Science.gov (United States)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F

    2015-09-01

    Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  5. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  6. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  7. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    Science.gov (United States)

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive

  8. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Nathalia Cristine; Junqueira, Jose Luiz Cinta; Panzarella, Francine Keuhi; Raitz, Ricardo [Sao Leopoldo Mandic Research Center, Dept. of Oral Radiology, College of Dentistry, Sao Paulo (Brazil); Brriviera, Mauricio [Dept. of Oral Radiology, College of Dentistry, Catholic University of Brasilia, Sao Paulo (Brazil)

    2017-03-15

    This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

  9. Imagenological characterization by Computerized Axial Tomography of the primary intracranial tumors

    International Nuclear Information System (INIS)

    Sosa Rivera, Manuel; Quintas Santana, Maria

    2009-01-01

    A descriptive observational study to 56 patients with imagenological diagnosis of primary intracranial neoplasia attended in the service of imagenology of the Provincial Docent Hospital 'Dr. Antonio Luaces Iraola' was carried out from March 1st 2006 to February 1st 2008, with the aim of characterizing these injuries by Computerized Axial Tomography and establishing an evaluation with the histological diagnosis. A questionnaire with the following variables was applied: sex, presuntive age, clinic, topographical characteristics (location, size, tumoral density, changes with administration of the resistance, calcifications, effect of mass and evaluation of the imagenological diagnosis with the histological diagnosis. Masculine sex and the group of ages of 60 are more predominated. The more frequent clinical manifestations were migraine, convulsions, difficulty to walk and vertigo. The size of the injury that prevailed was of 5, 9 and 2, 1 cm with supratentorial location. The majority of primary intracranial neoplasms were hypodense, and enhancement of the injuries with the administration of the resistance was observed. The mass effect bears a close relation with the location and size of the injury. The imagenological diagnosis fitted in with the histological one, being the gliomas the more frequent histological type

  10. Development of Axial Tomography for Steam Explosion Study

    International Nuclear Information System (INIS)

    Lee, Jae Young; Seo, Shi Won; Song, Jin Ho

    2006-01-01

    Visual understanding of complicated system leads us often to the intuitive enlightenment of the invisible causes of the effect. When it is formulated based on the rigorous mathematics, the produced formula or correlation will be very useful in design and analysis of the engineering system. In this point of view, the tomography technology can be a tool to meet such a purpose. However, the traditional hard ray tomography using high energy radiation cannot meet the case due to heavy shielding structure which obstructs access of the sensing unit to the very complicated and limited space. Therefore, the recent development of the electric tomography is noteworthy in the application to the industrial process monitoring. It has the merit not only of low cost but also of easier access to the limited space than the hard ray tomography

  11. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  12. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sondheimer, H.M. (Upstate Medical Center, Syracuse, NY); Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-05-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease.

  13. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  14. Patient radiation exposure in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, V [Meditsinska Akademiya, Sofia (Bulgaria)

    1980-01-01

    Radiation exposure to patients undergoing axial computerized tomography as a tool of neurological X-ray diagnostics was studied. Doses thereby delivered were compared with those from routine head films at X-ray tube parameters 200 W, 70 kV, and 70 cm target-to-patient distance. Radiation exposures were analyzed with a view to improving shielding and procedural techniques. Comparisons were made using LiF TLD measurements with an Alderson phantom (standard for axial computer tomography). Skin and intracranial space doses were compared using two computers, Siretom I and Siretom 2000, for various positionings: frontal, fronto-lateral, temporal, temporo-occipital, and occipital. In addition, patient body doses with or without shielding and doses to subjects attending sick children or restless adults were examined. Achievable protection was estimated for lead shields of 0.5 mm lead equivalent. It was concluded that radiation doses delivered to neurologic patients undergoing axial computer tomography are smaller than those resulting from conventional X-ray examinations.

  15. SPECT: Theoretical aspecte and evolution of emission computed axial tomography

    International Nuclear Information System (INIS)

    Brunol, J.; Nuta, V.

    1981-01-01

    We have detailed certain of the elements of 3-D image reconstruction from axial projections. Two of the aspects specific to nuclear medicine have been analysed namely self-absorption and statistics. In our view, the development of ECAT in the months to come must hence proceed in two essential directions: - application to dynamic cardiac imagery (multigated). Results of this type have been obtained over 8 months in the Radioisotope Service of Cochin Hospital in Paris. It must be stressed here that the number of images to be processed then becomes considerable (multiplication by the gate factor yielding more than 100 images), the more the statistics are reduced due to the fact of the temporal separation. The obtaining of good image quality requires sophisticated quadri-dimensional processing. It follows that the computing times, with all the mini-computers available in nuclear medicine, then become much too great to envisage really application in hospital routine (several hours of computing). This is the reason why we connected an array processor with the IMAC system. This very powerful system (several tens of times the power of a mini-computer) will reduce the time of such computing to less than 10 minutes. New elements can be introduced into the reconstruction algorithm (static case opposite the foregoing one). These important elements of improvement are to the detriment of space and hence of computing time. Here again, the use of an array processor appears indispensable. It is to recall that the ECAT is today a currently used method, the theoretical analyses that it has necessitated have opened the way to new effective methods of tomography by 'Slanted Hole'. (orig.) [de

  16. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  17. Regional myocardial perfusion assessed by N-13 labeled ammonia and positron emission computerized axial tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Selin, C.E.; Kuhl, D.E.

    1978-01-01

    The usefulness of 13 NH 3 as an indicator of regional myocardial perfusion suitable for positron emission computerized axial tomography (PCT) has been suggested. However, the relationship between myocardial blood flow and uptake of 13 NH 3 has not been examined quantitatively. It was therefore the purpose of the current investigation to quantitate the relationship of myocardial 13 NH 3 tissue concentration to myocardial blood flow and to examine its suitability for PCT imaging. Twelve open chest dogs were studied. In 8 of the dogs 25 imaging procedures with 13 NH 3 and PCT were performed. In the remaining four dogs the relationship between flow and myocardial 13 NH 3 tissue concentration was assessed by in vitro techniques. The PCT technique provided high quality cross-sectional images of the distribution of 13 NH 3 in left ventricular myocardium. No significant redistribution of 13 NH 3 in myocardium occurred with time. Alterations in regional myocardial blood flow resulted in changes of the regional distribution of 13 NH 3 that were readily appreciated on the PCT images

  18. Three-dimensional S-wave tomography under Axial Seamount

    Science.gov (United States)

    Baillard, C.; Wilcock, W. S. D.; Arnulf, A. F.; Tolstoy, M.; Waldhauser, F.

    2017-12-01

    Axial Seamount is a submarine volcano located at the intersection of the Juande Fuca Ridge and the Cobb-Eickelberg hotspot 500 km off the coast of thenorthwestern United States. The seamount, which rises 1 km above the seafloor, ischaracterized by a shallow caldera that is elongated in the N-S direction, measure 8km by 3 km and sits on top of a 14 km by 3 km magma reservoir. Two eruptive eventsin 1998 and 2011 motivated the deployment in 2014 of a real time cabled observatorywithin the Axial caldera, as part of the Ocean Observatories Initiative (OOI).Theobservatory includes a network of seven seismometers that span the southern half ofthe caldera. Five months after the observatory came on-line in November 2014, thevolcano erupted on April 24, 2015. Well over 100,000 events were located in thevicinity of the caldera, delineating an outward dipping ring fault that extends fromnear the surface to the magma body at 2 km depth and which accommodatesinflation and deflation of the volcano.The initial earthquake locations have beenobtained with a one-dimensional velocity model but the travel time residuals suggeststrong heterogeneities. A three-dimensional P-wave velocity model, obtained bycombining multichannel and ocean bottom seismometer refraction data, is being usedto refine locations but the three-dimensional S-wave structure is presently unknown.In most mid-ocean ridge settings, the distribution of earthquakes is not conducive forjoint inversions for S-wave velocity and hypocentral parameters because there are fewcrossing ray paths but at Axial the presence of a ring fault that is seismically active atall depths on both the east and west side of the caldera, provides a reasonablegeometry for such efforts. We will present the results of joint inversions that assumethe existing three-dimensional P wave velocity model and solve for VP/VS structure andhypocentral parameters using LOTOS, an algorithm that solves the forward problemusing ray bending.The resulting model

  19. Positron Emission Tomography (PET) in the oncologic clinical practice

    International Nuclear Information System (INIS)

    Serna M, J.A.; Luviano, C.; Martinez V, D.; Maldonado S, A.

    2005-01-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  20. Axial sesamoiditis in the horse: A review

    Directory of Open Access Journals (Sweden)

    Christelle Le Roux

    2018-03-01

    Full Text Available Axial sesamoiditis or osteitis of the proximal sesamoid bones (PSBs in the horse is described as a rare condition. The cause remains unknown and speculative, with vascular, infectious, and traumatic aetiologies implicated. It is specifically associated with injury of the palmar or plantar ligament (PL, also known as the intersesamoidean ligament. Imaging findings are generally rewarding and radiological changes are typical, if not pathognomonic, for the condition. Lesions consist of bone lysis at the apical to mid-body axial margins of the PSBs, with variable degrees of joint effusion. Radiographic technique warrants careful attention to make a diagnosis, and exposure factors may need to be adjusted. Perineural, intra-articular and intra-thecal anaesthesia does not seem to provide consistent improvement of lameness in these cases, with literature reporting inconsistent findings. Ultrasonographic findings include digital flexor sheath effusion, loss of the normal fibre structure of the PL at its attachment to the PSBs, abnormal echogenicity or change in thickness of the PL, and irregular hyperechoic cortical margins of the axial margins of the PSBs. Scintigraphy, computed tomography and magnetic resonance imaging, although not necessary to make a diagnosis, may add valuable information regarding the location and extent of lesions. The prognosis remains guarded to poor for return to athletic function. The focus of this paper is a comprehensive review of the proposed aetiopathogenesis of the condition, the prognosis, and a summary of the literature findings with focus on the notable diagnostic imaging features, including radiography, ultrasonography, scintigraphy, computed tomography and magnetic resonance imaging.

  1. Strut fracture and disc embolization of a Björk-Shiley mitral valve prosthesis: localization of embolized disc by computerized axial tomography.

    Science.gov (United States)

    Larrieu, A J; Puglia, E; Allen, P

    1982-08-01

    The case of a patient who survived strut fracture and embolization of a Björk-Shiley mitral prosthetic disc is presented. Prompt surgical treatment was directly responsible for survival. In addition, computerized axial tomography of the abdomen aided in localizing and retrieving the embolized disc, which was lodged at the origin of the superior mesenteric artery. A review of similar case reports from the literature supports our conclusions that the development of acute heart failure and absent or muffled prosthetic heart sounds in a patient with a Björk-Shiley prosthetic heart valve inserted prior to 1978 should raise the possibility of valve dysfunction and lead to early reoperation.

  2. Estimation of Material Distribution at the Premixing Stage in the Steam Explosion Event using the Electric Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, S. W.; Lee, C. H. [Handong Global Univ., Pohang (Korea, Republic of)

    2008-02-15

    Axixal tomography code which is developed in 2005-06, is improved through the present research. In the first year, the objects of project are the measurement of water level and measurement of bubble distribution that are significant measurement factor used in axial tomography. To improve the previous axial tomography code, we gave attention to inverse algorithm. Inverse algorithm is the method to solve a system of equations that has many unknowns than the number of equations. The system of equations is not solved exactly. To find a more exact approximated solution of the system of equations, it is proposed to the number of equations increasing. If the number of electrode is increased, image reconstruction results are better than the previous one, because of the number of equations corresponded to the number of independent measurement. Therefore, the axial tomography code was changed by increase in the number of electrode. And phase distribution was reconstructed by new axial tomography code. As the results, image reconstruction performance is improved. The water level and bubble distribution is measured more precisely than the previous study.

  3. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  4. Dispersion free full range spectral intensity optical coherence tomography

    DEFF Research Database (Denmark)

    Jensen, Mikkel; Israelsen, Niels Møller; Maria, Michael

    2017-01-01

    Optical coherence tomography (OCT) is a non-invasive imaging technique with many applications and widespread use in ophthalmology [1]. The axial resolution in OCT is inversely proportional to the bandwidth of the optical source used, but the improved axial resolution comes at the price of more...

  5. Evidence supporting the use of cone-beam computed tomography in orthodontics.

    NARCIS (Netherlands)

    Vlijmen, O.J.C. van; Kuijpers, M.A.R.; Berge, S.J.; Schols, J.G.J.H.; Maal, T.J.J.; Breuning, H.; Kuijpers-Jagtman, A.M.

    2012-01-01

    BACKGROUND: The authors conducted a systematic review of cone-beam computed tomography (CBCT) applications in orthodontics and evaluated the level of evidence to determine whether the use of CBCT is justified in orthodontics. TYPES OF STUDIES REVIEWED: The authors identified articles by searching

  6. Comparison of 3D cellular imaging techniques based on scanned electron probes: Serial block face SEM vs. Axial bright-field STEM tomography.

    Science.gov (United States)

    McBride, E L; Rao, A; Zhang, G; Hoyne, J D; Calco, G N; Kuo, B C; He, Q; Prince, A A; Pokrovskaya, I D; Storrie, B; Sousa, A A; Aronova, M A; Leapman, R D

    2018-06-01

    Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50-100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach. Copyright © 2018. Published by Elsevier Inc.

  7. Evaluation for computerized axial tomography to three anthropomorphic methods to estimate the thigh muscle area

    International Nuclear Information System (INIS)

    Fernandez Vieitez, Jorge Alberto; Alvarez Cuesta, Jose Alberto; Williams Wilson, Luis

    2001-01-01

    Three anthropometric methods to estimate the thigh muscle area (TMA, cm) were evaluated. Seventeen young males were taken as a sample. The TMA was estimated by using the formulas of Gurney-Jellife, Jones-Pearson, Housh, and others. In the same place where the measurements of circumferences and skinfolds were made, the TAM was determined by computerized axial tomography. It was used as a reference criterion with which the anthropometric values were compared. The methods of Gurney-Jellife and Jones-Pearson significantly overestimated the TAM obtained by CAT (9.0 + - 12.8 cm 2 [4.4 %]; p = 0.01 and 22.0 + - 14.9 cm 2 [10.9 %]; p = 1.6 . 10-5, respectively), whereas that of Housh and others underestimated the values of CAT (-48.8 + - 11.7 cm 2 [24.1 %]; p = 9.4 . 10-12). The Gurney-Jellife equation was the only one that proved to be interchangeable with CAT, on obtaining a coefficient of correlation (r) and a slope of regression (b) for the difference and the average between both methods that were not statistically significant (r 0,421; b = 0,21 + - 0.12, p = 0.09). It was concluded that of the 3 studied anthropometric methods, the Gurney-Jellife method offers the most accurate TAM values

  8. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  9. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  10. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane.

    Science.gov (United States)

    Kim, Ji-Beom; Yi, Young; Kim, Jae-Young; Cho, Jae-Ho; Kwon, Min-Soo; Choi, Seung-Hyuk; Lee, Woo-Chun

    2017-08-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis.

  11. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun [Seoul Foot and Ankle Center, Dubalo Orthopaedic Clinic, Seochogu, Seoul (Korea, Republic of); Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk [Inje University Seoul Paik Hospital, Department of Orthopaedic Surgery, Jung-gu, Seoul (Korea, Republic of); Cho, Jae-Ho [Hallym University, ChunCheon Sacred Heart Hospital, Department of Orthopaedic Surgery, Chuncheon, GangWon-do (Korea, Republic of)

    2017-08-15

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  12. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    International Nuclear Information System (INIS)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun; Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk; Cho, Jae-Ho

    2017-01-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  13. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  14. Organo-axial volvulus of the small intestine: radiological case report and consideration for its mechanism.

    Science.gov (United States)

    Ishiguro, Toshitaka; Hiyama, Takashi; Nasu, Katsuhiro; Akashi, Yoshimasa; Minami, Manabu

    2017-07-01

    Gastrointestinal volvulus is mainly classified into two subtypes, mesentero-axial volvulus and organo-axial volvulus. The detailed imaging findings of organo-axial volvulus of the small intestine have never been reported as far as we know. In this article, we report a case of organo-axial volvulus of the small intestine, focusing on the computed tomography (CT) findings. An 80-year-old man was radiologically diagnosed as having organo-axial volvulus of the terminal ileum and it was confirmed by open surgery without adhesion or any other anatomical abnormalities. CT showed two specific findings, split-bowel sign and rotating-C sign, which we think reflect pathophysiologic features of organo-axial volvulus. We think the pathogenic mechanism of organo-axial volvulus can be explained by the convergence of the reversed-rotational twist following the formation of a twisted but non-obstructive circular loop, even if there is no adhesion. Radiologists should be aware that organo-axial volvulus can occur even in the small intestine, and in the case of small bowel obstruction with single transition point, the two pathophysiologic signs mentioned above must be looked for to diagnose the possibility of organo-axial volvulus.

  15. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  16. Pathological investigation of caries and occlusal pulpar exposure in donkey cheek teeth using computerised axial tomography with histological and ultrastructural examinations.

    Science.gov (United States)

    Toit, Nicole du; Burden, Faith A; Kempson, Sue A; Dixon, Padraic M

    2008-12-01

    Post-mortem examination of 16 donkey cheek teeth (CT) with caries (both peripheral and infundibular) and pulpar exposure were performed using computerised axial tomography (CAT), histology and scanning electron microscopy. CAT imaging was found to be useful to assess the presence and extent of caries and pulp exposure in individual donkey CT. Histology identified the loss of occlusal secondary dentine, and showed pulp necrosis in teeth with pulpar exposure. Viable pulp was present more apically in one exposed pulp horn, with its occlusal aspect sealed off from the exposed aspect of the pulp horn by a false pulp stone. Scanning electron microscopy showed the amelo-cemental junction to be a possible route of bacterial infection in infundibular cemental caries. The basic pathogenesis of dental caries in donkeys appears very similar to its description in other species.

  17. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  18. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  19. A novel diagnostic method (spectral computed tomography of sacroiliac joints) for axial spondyloarthritis.

    Science.gov (United States)

    Zhang, Ping; Yu, Kai Hu; Guo, Rui Min; Ran, Jun; Liu, Yao; Morelli, John; Runge, Val M; Li, Xiao Ming

    2016-08-01

    To evaluate the diagnostic value of spectral computed tomography (CT) of sacroiliac joints for axial spondyloarthritis (SpA). We retrospectively analyzed the records of 125 patients with low back pain (LBP) suspected of having SpA. Each patient underwent sacroiliac joint spectral CT examination. Water- and calcium-based material decomposition images were reconstructed. After 3-6 months of follow-up, 76 were diagnosed with SpA, and the remaining 49 patients were diagnosed with nonspecific LBP (nLBP). The slope of sacroiliac bone marrow HU (Hounsfield unit) curve (λHU), CT value, and bone marrow to normal muscle ratios of water and calcium concentrations in the ilium and sacrum were calculated and compared between nLBP and SpA patients. The iliac λHU was 8.26 ± 3.91 for nLBP and 9.81 ± 4.92 for SpA. The mean iliac ratios of water and calcium concentrations were 1.04 ± 0.03 and 21.67 ± 4.40, respectively, for nLBP, and 1.07 ± 0.04 and 111.5 ± 358.98, respectively, for SpA. The mean iliac CT values were 311.12 ± 86.52 HU for nLBP and 423.97 ± 127.51 HU for SpA. There were statistically significant differences in iliac ratios of water and calcium concentrations, CT value, and λHU between nLBP and SpA patients (p sacroiliac joints of SpA patients. Copyright © 2015. Published by Elsevier B.V.

  20. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Lampmann, L.E.H.

    1982-01-01

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  1. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  2. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  3. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  4. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    International Nuclear Information System (INIS)

    Nizic, Dinko

    2012-01-01

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  5. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nizic, Dinko [Zagreb University Hospital Center, Clinical Institute of Diagnostic and Interventional Radiology, Zagreb (Croatia)

    2012-09-15

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  6. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  7. Is tomography of intervertebral disc calcification useful in children?

    International Nuclear Information System (INIS)

    Ginalski, J.M.; Landry, M.; Gudinchet, F.; Schnyder, P.

    1992-01-01

    In the past ten years, we have found cervical intervertebral disc calcification in three children on plain films of the cervical spine made because of cervical pain. In each case, we required further radiological investigations, antero-posterior and lateral linear tomography for two children and an axial computed tomography for one child. In each case, tomography revealed no supplementary useful information. On retrospect, we think that these examinations caused unnecessary irradiation and that they should only be carried out in the rare circumstances when disc calcification is associated with neurological symptoms. (orig.)

  8. Is tomography of intervertebral disc calcification useful in children

    Energy Technology Data Exchange (ETDEWEB)

    Ginalski, J M; Landry, M; Gudinchet, F; Schnyder, P [Lausanne Univ. Hospital (Switzerland). Dept. of Radiology

    1992-04-01

    In the past ten years, we have found cervical intervertebral disc calcification in three children on plain films of the cervical spine made because of cervical pain. In each case, we required further radiological investigations, antero-posterior and lateral linear tomography for two children and an axial computed tomography for one child. In each case, tomography revealed no supplementary useful information. On retrospect, we think that these examinations caused unnecessary irradiation and that they should only be carried out in the rare circumstances when disc calcification is associated with neurological symptoms. (orig.).

  9. Axial magnetic field produced by axially and radially magnetized permanent rings

    International Nuclear Information System (INIS)

    Peng, Q.L.; McMurry, S.M.; Coey, J.M.D.

    2004-01-01

    Axial magnetic fields produced by axially and radially magnetized permanent magnet rings were studied. First, the axial magnetic field produced by a current loop is introduced, from which the axial field generated by an infinitely thin solenoid and by an infinitely thin current disk can be derived. Then the axial fields produced by axially and by radially magnetized permanent magnet rings can be obtained. An analytic formula for the axial fields produced by two axially magnetized rings is given. A permanent magnet with a high axial gradient field is fabricated, the measured results agree with the theoretical calculation very well. As an example, the axial periodic field produced by an arrangement of alternating axially and radially magnetized rings has been discussed

  10. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  11. Industrial tomography applied to reactor safety

    International Nuclear Information System (INIS)

    Kruger, R.P.

    1977-01-01

    Work has begun which explores the use of Computed Axial Tomography (CAT), boundary detection, and internal surface reconstruction techniques in industrial nondestructive testing applications. This initial work is intended to inform the reader of the existence and interrelated nature of these techniques through the use of a realistic simulation of an industrial inspection problem

  12. Multi-axial response of idealized cermets

    International Nuclear Information System (INIS)

    Pickering, E.G.; Bele, E.; Deshpande, V.S.

    2016-01-01

    The yield response of two idealized cermets comprising mono and bi-disperse steel spheres in a Sn/Pb solder matrix has been investigated for a range of axisymmetric stress states. Proportional stress path experiments are reported, from which are extracted the initial yield surfaces and their evolution with increasing plastic strain. The initial yield strength is nearly independent of the hydrostatic pressure but the strain hardening rate increases with stress triaxiality up to a critical value. For higher triaxialities, the responses are independent of hydrostatic pressure. Multi-axial measurements along with X-ray tomography were used to demonstrate that the deformation of these idealized cermets occurs by two competing mechanisms: (i) a granular flow mechanism that operates at low levels of triaxiality, where volumetric dilation occurs under compressive stress states, and (ii) a plastically incompressible mechanism that operates at high stress triaxialities. A phenomenological viscoplastic constitutive model that incorporates both deformation mechanisms is presented. While such multi-axial measurements are difficult for commercial cermets with yield strengths on the order of a few GPa, the form of their constitutive relation is expected to be similar to that of the idealized cermets presented here.

  13. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  14. CASE SERIES Multi-detector computer tomography venography ...

    African Journals Online (AJOL)

    in the curved coronal plane with particular reference to the course of the common and external iliac veins through the pelvis. Axial venous. Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with ...

  15. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    Science.gov (United States)

    Antony, Bhavna; Abràmoff, Michael D.; Tang, Li; Ramdas, Wishal D.; Vingerling, Johannes R.; Jansonius, Nomdo M.; Lee, Kyungmoo; Kwon, Young H.; Sonka, Milan; Garvin, Mona K.

    2011-01-01

    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct the distinct axial artifacts in SD-OCT images. The method was quantitatively validated using nine pairs of OCT scans obtained with orthogonal fast-scanning axes, where a segmented surface was compared after both datasets had been corrected. The mean unsigned difference computed between the locations of this artifact-corrected surface after the single-spline and dual-spline correction was 23.36 ± 4.04 μm and 5.94 ± 1.09 μm, respectively, and showed a significant difference (p < 0.001 from two-tailed paired t-test). The method was also validated using depth maps constructed from stereo fundus photographs of the optic nerve head, which were compared to the flattened top surface from the OCT datasets. Significant differences (p < 0.001) were noted between the artifact-corrected datasets and the original datasets, where the mean unsigned differences computed over 30 optic-nerve-head-centered scans (in normalized units) were 0.134 ± 0.035 and 0.302 ± 0.134, respectively. PMID:21833377

  16. Optical coherence tomography of the rat cochlea

    NARCIS (Netherlands)

    Wong, B. J. F.; de Boer, JF; Park, B.H.; Chen, ZP; Nelson, JS

    2000-01-01

    Optical coherence tomography (OCT) was used to image the internal structure of a rat cochlea (ex vivo). Immediately following sacrifice, the temporal bone of a Sprague-Dawley rat was harvested. Axial OCT cross sectional images lover regions of interest, 1x1 mm-2x8 mm) were obtained with a spatial

  17. Phase-conjugate optical coherence tomography

    International Nuclear Information System (INIS)

    Erkmen, Baris I.; Shapiro, Jeffrey H.

    2006-01-01

    Quantum optical coherence tomography (Q-OCT) offers a factor-of-2 improvement in axial resolution and the advantage of even-order dispersion cancellation when it is compared to conventional OCT (C-OCT). These features have been ascribed to the nonclassical nature of the biphoton state employed in the former, as opposed to the classical state used in the latter. Phase-conjugate OCT (PC-OCT) shows that nonclassical light is not necessary to reap Q-OCT's advantages. PC-OCT uses classical-state signal and reference beams, which have a phase-sensitive cross correlation, together with phase conjugation to achieve the axial resolution and even-order dispersion cancellation of Q-OCT with a signal-to-noise ratio that can be comparable to that of C-OCT

  18. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  19. [Inflammatory spinal diseases: axial spondyloarthritis : Central importance of imaging].

    Science.gov (United States)

    Baraliakos, X; Fruth, M; Kiltz, U; Braun, J

    2017-03-01

    The diagnosis of axial spondyloarthritis (axSpA) includes classical ankylosing spondylitis (AS) as well as earlier stages and abortive courses of the disease, in which structural alterations have not yet occurred. These are classified as non-radiographic axSpA (nr-axSpa). Inflammatory changes in the entire axial skeleton are characteristic for axSpA and can be visualized by magnetic resonance imaging (MRI), while in most patients structural alterations, such as new bone formation with syndesmophytes and ankylosis develop in the later course of the disease. These bony alterations can best be visualized by conventional radiography and by computed tomography. Certain MRI sequences are nowadays considered as the standard method for depiction of inflammatory changes in axSpA. The introduction of MRI has led to a paradigm shift for this disease because the inflammatory lesions characteristic for the disease can be visualized at an early stage using appropriate MRI sequences.

  20. Preliminary results with gamma-tomography using a rotating gammacamera

    International Nuclear Information System (INIS)

    Raynaud, C.; Soussaline, F.; Todd-Pokropek, A.; Zurowski, S.; Kellershohn, C.

    1980-03-01

    In order to perform single photon emission tomography also known as gamma-tomography (GT). We have used a system comprising a GE 400 T coupled to an Informatek Simis 3 computer. Up to a maximum of 64 transverse axial tomograms can be reconstructed and then sorted to obtain sagittal and frontal slices through the volume reconstructed. Of the 48 patients so far studied, 29 had brain scans for tumor and 29 liver scans for tumor, abcess or cirrhosis. The results obtained are indicated

  1. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes

    International Nuclear Information System (INIS)

    Kench, P L; Meikle, S R; Lin, J; Gregoire, M C

    2011-01-01

    Multiple pinholes are advantageous for maximizing the use of the available field of view (FOV) of compact small animal single photon emission computed tomography (SPECT) detectors. However, when the pinholes are aligned axially to optimize imaging of extended objects, such as rodents, multiplexing of the pinhole projections can give rise to inconsistent data which leads to 'ghost point' artefacts in the reconstructed volume. A novel four pinhole collimator with a baffle was designed and implemented to eliminate these inconsistent projections. Simulation and physical phantom studies were performed to investigate artefacts from axially aligned pinholes and the efficacy of the baffle in removing inconsistent data and, thus, reducing reconstruction artefacts. SPECT was performed using a Defrise phantom to investigate the impact of collimator design on FOV utilization and axial blurring effects. Multiple pinhole SPECT acquired with a baffle had fewer artefacts and improved quantitative accuracy when compared to SPECT acquired without a baffle. The use of four pinholes positioned in a square maximized the available FOV, increased acquisition sensitivity and reduced axial blurring effects. These findings support the use of a baffle to eliminate inconsistent projection data arising from axially aligned pinholes and improve small animal SPECT reconstructions.

  2. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  3. Complementary medicine for axial spondyloarthritis: is there any scientific evidence?

    Science.gov (United States)

    Danve, Abhijeet; Deodhar, Atul

    2018-04-09

    Majority of patients with axial spondyloarthritis (axSpA) report use of complementary and alternative medicine (CAM) therapies before and even after the diagnosis, due to perceived efficacy and wide-spread belief that these modalities lack side effects. In this review, we describe the available scientific evidence for the CAM therapies in axSpA. Clinical trials of the CAM therapies in axSpA are generally hampered by small sample size, short duration, difficulties in blinding, lack of control groups and strong placebo effect. Nonetheless, exercise programs like Pilates and mind-body techniques such as Tai Chi may have favorable effect on the disease activity and function. Although not yet confirmed, the modulation of the microbiome with the help of probiotics or fecal transplant has face validity given the evolving scientific rationale. Diet has only limited role in the management of axSpA. Deep tissue massage, omega-3 fatty acids and Stanger bath were found to be useful in small studies. CAM therapies are not always entirely well tolerated, particularly the manipulative techniques like chiropractic and Tui-na in patients with advanced disease and osteoporosis. There are no trials of yoga in axSpA despite the wider acceptance and use of yoga as an effective mind-body technique. Larger and better quality clinical trials of CAM therapies are needed to confirm their efficacy and safety in the management of axSpA and to include them in the 'mainstream' medicine.

  4. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  5. Using axial magnetized permanent rings to build axial gradient magnetic field

    International Nuclear Information System (INIS)

    Peng Quanling

    2003-01-01

    Axial field produced by an axially magnetized permanent ring was studied. For two permanent magnet rings, if they are magnetized in the same direction, a nearly uniform axial field can be produced; if they are magnetized in opposite direction, an axial gradient field can be produced in the region between the two permanent rings, with the field strength changing from -B 0 to B 0 . A high gradient axial magnetic field has been built by using two axially magnetized permanent rings, the measured field results agree with the PANDIRA calculation very well. It is desirable that the field gradient can be varied to match various requirements. A method to produce the variable gradient field is presented. Axial gradient field can also be used as a beam focusing facility for linear accelerator if axial periodic field can be produced. Its magnetic field is similar to that of a solenoid, in which, large stray field will leak to the outside environment. A method for shielding the outside stray field is discussed

  6. Positron Emission Tomography (PET) in the oncologic clinical practice; Tomografia por Emision de Positrones (PET) en la practica clinica oncologica

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J A; Luviano, C; Martinez V, D [Hospital Angeles del Pedregal Mexico DF (Mexico); Maldonado S, A [Centro PET Complutense, Madrid (Spain)

    2005-07-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  7. Diagnostic value of sectional images obtained by emission tomography

    International Nuclear Information System (INIS)

    Roucayrol, J.C.

    1981-01-01

    It is now possible to obtain clear images of the various planes in and around a structure with ultra-sounds (echotomography), X-rays (computerized tomography) and recently, gamma-rays from radioactive substances (emission tomography). Axial transverse tomography, which is described here, is to conventional scintigraphy what CT scan is to radiography. It provides images of any structure capable of concentrating sufficiently a radioactive substance administered intravenously. These images are perpendicular to the longitudinal axis of the body. As shown by examples in the liver, lungs and myocardium, lesions which had passed unnoticed with other exploratory techniques can now be demonstrated, and the location, shape and extension of known lesions can be more accurately assessed. Emission tomography already has its place in modern diagnostic procedures side by side with echotomography and CT scan [fr

  8. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  9. Optimization of residual heat removal pump axial thrust and axial bearing

    International Nuclear Information System (INIS)

    Schubert, F.

    1996-01-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies

  10. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  11. Evolution of the dinosauriform respiratory apparatus: new evidence from the postcranial axial skeleton.

    Science.gov (United States)

    Schachner, Emma R; Farmer, C G; McDonald, Andrew T; Dodson, Peter

    2011-09-01

    Examination of the thoracic rib and vertebral anatomy of extant archosaurs indicates a relationship between the postcranial axial skeleton and pulmonary anatomy. Lung ventilation in extant crocodilians is primarily achieved with a hepatic piston pump and costal rotation. The tubercula and capitula of the ribs lie on the horizontal plane, forming a smooth thoracic "ceiling" facilitating movement of the viscera. Although the parietal pleura is anchored to the dorsal thoracic wall, the dorsal visceral pleura exhibits a greater freedom of movement. The air sac system and lungs of birds are associated with bicapitate ribs with a ventrally positioned capitular articulation, generating a rigid and furrowed rib cage that minimizes dorsoventral changes in volume in the dorsal thorax. The thin walled bronchi are kept from collapsing by fusion of the lung to the thorax on all sides. Data from this study suggest a progression from a dorsally rigid, heterogeneously partitioned, multichambered lung in basal dinosauriform archosaurs towards the small entirely rigid avian-style lung that was likely present in saurischian dinosaurs, consistent with a constant volume cavum pulmonale, thin walled parabronchi, and distinct air sacs. There is no vertebral evidence for a crocodilian hepatic piston pump in any of the taxa reviewed. The evidence for both a rigid lung and unidirectional airflow in dinosauriformes raises the possibility that these animals had a highly efficient lung relative to other Mesozoic vertebrates, which may have contributed to their successful radiation during this time period. Copyright © 2011 Wiley-Liss, Inc.

  12. Phase analysis in gated blood pool tomography. Detection of accessory conduction pathway

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro (Kanazawa Univ. (Japan). School of Medicine)

    1984-02-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome.

  13. Imaging of basal cell carcinoma by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, M A L M; Norrenberg, S; Jemec, G B E

    2012-01-01

    With the continued development of noninvasive therapies for basal cell carcinoma (BCC) such as photodynamic therapy and immune therapies, noninvasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography (HD-OCT) is a high-resolution imaging tool, wit......, with micrometre resolution in both transversal and axial directions, enabling visualization of individual cells up to a depth of around 570 μm, and filling the imaging gap between conventional optical coherence tomography (OCT) and reflectance confocal microscopy (RCM)....

  14. Process and apparatus for examination by penetrating radiations, particularly by tomography

    International Nuclear Information System (INIS)

    Taylor, S.K.; Erker, J.W.; Carper, R.L.

    1980-01-01

    This invention concerns a process and apparatus for examination by penetrating radiation, particularly by tomography. Specifically, the invention refers to the 'tacography' or computer assisted axial tomography machines and, in particular, the machines working by translational and rotational displacement. Such a translational and rotational scanner is designed so that the radiation source and detectors move by translation on a carriage at non constant speed. Data samples are taken, for unit distances in space and not during unit times [fr

  15. BWR AXIAL PROFILE

    International Nuclear Information System (INIS)

    Huffer, J.

    2004-01-01

    The purpose of this calculation is to develop axial profiles for estimating the axial variation in burnup of a boiling water reactor (BWR) assembly spent nuclear fuel (SNF) given the average burnup of an assembly. A discharged fuel assembly typically exhibits higher burnup in the center and lower burnup at the ends of the assembly. Criticality safety analyses taking credit for SNF burnup must account for axially varying burnup relative to calculations based on uniformly distributed assembly average burnup due to the under-burned tips. Thus, accounting for axially varying burnup in criticality analyses is also referred to as accounting for the ''end effect'' reactivity. The magnitude of the reactivity change due to ''end effect'' is dependent on the initial assembly enrichment, the assembly average burnup, and the particular axial profile characterizing the burnup distribution. The set of bounding axial profiles should incorporate multiple BWR core designs and provide statistical confidence (95 percent confidence that 95 percent of the population is bound by the profile) that end nodes are conservatively represented. The profiles should also conserve the overall burnup of the fuel assembly. More background on BWR axial profiles is provided in Attachment I

  16. Spectral shaping for non-Gaussian source spectra in optical coherence tomography

    NARCIS (Netherlands)

    Tripathi, R; Nassif, N. A.; Nelson, JS; Park, B.H.; de Boer, JF

    2002-01-01

    We present a digital spectral shaping technique to reduce the sidelobes (ringing) of the axial point-spread function in optical coherence tomography for non-Gaussian-shaped source spectra. The spectra of two superluminescent diodes were combined to generate a spectrum with significant modulation.

  17. The research on flow pulsation characteristics of axial piston pump

    Science.gov (United States)

    Wang, Bingchao; Wang, Yulin

    2017-01-01

    The flow pulsation is an important factor influencing the axial piston pump performance. In this paper we implement modeling and simulation of the axial piston pump with AMESim software to explore the flow pulsation characteristics under various factors . Theory analysis shows the loading pressure, angular speed, piston numbers and the accumulator impose evident influence on the flow pulsation characteristics. This simulation and analysis can be used for reducing the flow pulsation rate via properly setting the related factors.

  18. Single photon emission computed tomography and oth selected computer topics

    International Nuclear Information System (INIS)

    Frey, G.D.

    1981-01-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification. Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions

  19. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  20. Correction of distortions in optical coherence tomography imaging of the eye

    Energy Technology Data Exchange (ETDEWEB)

    Podoleanu, Adrian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Charalambous, Ismini [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Plesea, Lucian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Dogariu, Aristide [School of Optics, CREOL, University of Central Florida, Orlando, FL (United States); Rosen, Richard [Advanced Retinal Imaging Center, New York Eye and Ear Infirmary, NY (United States)

    2004-04-07

    Optical coherence tomography (OCT) images are affected by artefacts. These artefacts are the result of different factors such as refraction, curvature of the intermediate layers up to the depth of interest and the scanning procedure. The effect of such errors is different, depending on the way the image is acquired, either en-face or longitudinal OCT. We quantify the distortions by evaluating a lateral and an axial error. These measure the lateral and axial deviations of each image point from the object point inside the tissue. We show that the axial distortion can be larger than the achievable depth resolution in modern OCT systems. We have investigated these errors in imaging different tissue: cornea and retina in vivo and an intraocular lens in vitro.

  1. Novel developments in Fourier domain optical coherence tomography and nonlinear tomographic interferometry

    OpenAIRE

    Mallat, Kamel

    2014-01-01

    In this thesis we present novel methods to improve the limitations in Optical Coherence Tomography (OCT). They are divided into two parts. The first part deals with the axial resolution limitation in OCT systems. We give a description of the Fourier Domain OCT (FDOCT), and then we show theoretically how to enhance the axial resolution in a particular case of a two-layer sample where one of the two layers is moving continuously, while these two layers are separated by a distance lower than the...

  2. Prospective Comparison of F-18 Choline PET/CT Scan Versus Axial MRI for Detecting Bone Metastasis in Biochemically Relapsed Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Wouter Huysse

    2017-10-01

    Full Text Available We compared fluor-18 choline positron emission tomography/computed tomography (PET/CT and axial skeleton magnetic resonance imaging (MRI prospectively obtained for the detection of bone metastases in non-castrated patients with biochemically recurrent prostate cancer following primary treatment. PET/CT was performed 45 min post-injection of 3–4 MBq/kg F-18 methyl choline. MRI included T1- and fluid sensitive T2-weighted images of the spine and pelvis. Readers were initially blinded from other results and all scans underwent independent double reading. The best valuable comparator (BVC defined the metastatic status. On the basis of the BVC, 15 out of 64 patients presented with 24 bone metastases. On a patient level, the sensitivity and specificity of MRI and PET were not significantly different. On a lesion level, the sensitivity of MRI was significantly better compared to PET, and the specificity did not differ significantly. In conclusion, axial MRI is an interesting screening tool for the detection of bone metastases because of its low probability of false negative results. However, F-18 choline PET is a valuable addition as it can overrule false positive MRI results and detect non-axial metastases.

  3. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  4. Report on the Dynamical Evolution of an Axially Symmetric Quasar ...

    Indian Academy of Sciences (India)

    retical arguments together with some numerical evidence. The evolution of the orbits is studied, as mass is transported from the disk to the nucleus. ... galaxies and non-axially symmetric quasar models (see Papadopoulos & Caranicolas.

  5. [Fluorescein angiography and optical coherence tomography findings in central fundus of myopic patients].

    Science.gov (United States)

    Avetisov, S E; Budzinskaya, M V; Zhabina, O A; Andreeva, I V; Plyukhova, A A; Kobzova, M V; Musaeva, G M

    2015-01-01

    Myopia prevalence grows alike in many countries, including Russia, regardless of geographical and population conditions. to assess fundus changes in myopic patients at different ocular axial lengths by means of modern diagnostic tools. The study enrolled 97 patients (194 eyes) aged 45 ± 20.17 years with myopia of different degrees. Besides a standard ophthalmic examination, all patients underwent fundus fluorescein angiography and optical coherence tomography. The occurrence of retinal pigment epithelium (RPE) atrophy (diffuse or focal) has been shown to increase with increasing ocular axial length. Only 27 eyes (28.1%) appeared intact. As myopia progression implies axial growth of the eye, it is associated with a more severe decrease in choroid, RPE, and photoreceptor layer thicknesses: the longer the anterior-posterior axis, the thinner the above mentioned fundus structures. Age-related changes in the fundus are also likely to be more pronounced in longer axes. Myopic traction maculopathy, which in our case appeared the main cause of increased retinal thickness, was diagnosed in 105 eyes, "outer" macular retinoschisis--in 40 eyes. Thus, modern diagnostic tools, such as fluorescein angiography and optical coherence tomography, enable objective assessment of the central fundus.

  6. Imaging of childhood torticollis due to atlanto-axial rotatory fixation.

    Science.gov (United States)

    Maheshwaran, S; Sgouros, S; Jeyapalan, K; Chapman, S; Chandy, J; Flint, G

    1995-12-01

    Atlanto-axial rotatory fixation is a rare cause of childhood torticollis. It may occur spontaneously or may be associated with trauma, upper respiratory tract infection or congenital abnormality of the cervical spine. Presentation is usually with persistent torticollis and "cock robin" deformity of the neck. In this paper the radiological experience in three patients is presented. Investigations included plain radiographs, plain anteroposterior tomography, CT and MRI. Displacement of the lateral mass of the atlas and the eccentric position of the odontoid peg can be seen in the plain films. CT scan can exclude fractures and confirm atlanto-axial rotation. The superimposition of CT images is demonstrated as a way of diagnosing subluxation. MRI offers better soft tissue differentiation and allows assessment of the integrity of the transverse ligament. This has an important bearing on the prognosis and may influence surgical treatment. It is important to recognise the plain film features of this uncommon condition and confirm the diagnosis with CT or MRI. The treatment options are discussed with particular reference to long term outcome.

  7. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.

  10. Ultrastructure and potential sub-seafloor evidence of bacteriogenic iron oxides from Axial Volcano, Juan de Fuca Ridge, north-east Pacific Ocean.

    Science.gov (United States)

    Kennedy, C B; Scott, S D; Ferris, F G

    2003-03-01

    Iron oxides from the caldera of Axial Volcano, a site of hydrothermal vent activity along the Juan de Fuca Ridge, were found to consist predominantly of microbial structures in hydrated whole mounts examined using an environmental scanning electron microscope. Novel observations were made of the iron oxides revealing the spatial relationships of the bacteria within to be more consistent with microbial mats than mineral precipitates. The bacterial structures are attributed to the sheaths of Leptothrix ochracea, the stalks of Gallionella ferruginea, and the filaments of a novel iron oxidizing PV-1 strain, based on the distinctive morphological characteristics of these three bacteria. Energy dispersive X-ray spectroscopy revealed the presence and distribution of Fe, Si, and Cl on the bacterial sheaths, stalks and filaments. The iron oxides were identified by X-ray diffraction to be two-line ferrihydrite, a poorly ordered iron oxyhydroxide. Adsorption of Si in particular to two-line ferrihydrite likely contributes to its stability on the seafloor, and might also be a preservation mechanism creating microfossils of the bacterial structures encrusted with ferrihydrite. Presumptive evidence of the sub-seafloor presence of L. ochracea, G. ferruginea and PV-1 at Axial Volcano was obtained from the presence of these bacteria on a trap that had been placed within an active vent, and also in a vent fluid sample. If indeed these bacteria are present in the sub-seafloor, it may be an indication that the surface expression of iron oxide deposits at Axial Volcano is minimal in comparison to what exists beneath the seafloor.

  11. The Distal Humerus Axial View: Assessment of Displacement in Medial Epicondyle Fractures.

    Science.gov (United States)

    Souder, Christopher D; Farnsworth, Christine L; McNeil, Natalie P; Bomar, James D; Edmonds, Eric W

    2015-01-01

    The assessment and treatment of childhood medial epicondyle humerus fractures continues to be associated with significant debate. Several studies demonstrate that standard radiographic views are unable to accurately portray the true displacement. Without reliable ways to assess the amount of displacement, how can we debate treatment and outcomes? This study introduces a novel imaging technique for the evaluation of medial epicondyle fractures. An osteotomy of a cadaveric humerus was performed to simulate a medial epicondyle fracture. Plain radiographs were obtained with the fracture fragment displaced anteriorly in 2-mm increments between 0 and 18 mm. Anteroposterior (AP), internal oblique (IR), lateral (LAT), and distal humerus axial (AXIAL) views were performed. Axial images were obtained by positioning the central ray above the shoulder at 15 to 20 degrees from the long axis of the humerus, centered on the distal humerus. Displacement (mm) was measured by 7 orthopaedic surgeons on digital radiographs. At 10 mm displacement, AP views underestimated displacement by 5.5±0.6 mm and IR views underestimated by 3.8±2.1 mm. On LAT views, readers were not able to visualize fragments with displacement. Displacement ≥10 mm from LAT views was overestimated by 1 reader by up to 4.6 mm and underestimated by others by up to 18.0 mm. AXIAL images more closely estimated the true amount of displacement, with a mean 1.5±1.1 mm error in measurement for displacement and a mean 0.8±0.7 mm error for displacements of ≥10 mm. AXIAL measurements correlated strongly with the actual displacement (r=0.998, Pdisplacement of medial epicondyle humerus fractures. The newly described AXIAL projection more accurately and reliably demonstrated the true displacement while reducing the need for advanced imaging such as computed tomography. This simple view can be easily obtained at a clinic visit, enhancing the surgeon's ability to determine the true displacement.

  12. The Australian government's review of positron emission tomography: evidence-based policy-making in action.

    Science.gov (United States)

    Ware, Robert E; Francis, Hilton W; Read, Kenneth E

    2004-06-21

    The Commonwealth Government constituted the Medicare Services Advisory Committee (MSAC) to implement its commitment to entrench the principles of evidence-based medicine in Australian clinical practice. With its recent review of positron emission tomography (PETReview), the Commonwealth intervened in an established MSAC process, and sanctioned the stated objective to restrict expenditure on the technology. In our opinion: The evaluation of evidence by PETReview was fundamentally compromised by a failure to meet the terms of reference, poor science, poor process and unique decision-making benchmarks. By accepting the recommendations of PETReview, the Commonwealth is propagating information which is not of the highest quality. The use of inferior-quality information for decision-making by doctors, patients and policy-makers is likely to harm rather than enhance healthcare outcomes.

  13. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  14. [The importance of axial computer tomography of the neurocranium in neurotraumatology (1) (author's transl)].

    Science.gov (United States)

    Gustorf, R

    1979-07-01

    Computer tomography enables exact diagnostic clarification of intracranial lesions in trauma of the neurocranium. Subdural or epidural as well as intracerebral haemorrhages can be localised, and a circumscribed contusion and cerebral oedema become tangible. The article reports on 90 patients subjected to computerized tomography following trauma of the neurocranium. In about 50% of the cases, the trauma had been caused by a traffic accident. About 27% of the accident victims were children and adolescents. In about one-half of the examined persons, subdural or epidural haemorrhages were found, whereas in about 20% of the cases, contusions, partly with mild haemorrhages, were seen. In about 10% of the cases a more or less severe oedema was seen. About 20% of the patients yielded no abnormal finding by CT in accordance with the age of the patient.

  15. [Dome-shaped macula: appearance on ultrasound and optical coherence tomography].

    Science.gov (United States)

    Chéour, M; Ben Aleya, N; Brour, J; Falfoul, Y; Agrebi, S; Skhiri, M; Kraïem, A

    2013-10-01

    The purpose of our work is to demonstrate the role of optical coherence tomography and ocular ultrasound in the diagnosis of the dome-shaped macula in high myopia. We report the case of a patient with high myopia who presented with a decrease in visual acuity and metamorphopsia in the left eye. She underwent visual acuity measurement, biomicroscopic examination and measurement of axial length. B-mode ultrasound and optical coherence tomography showed a projection of the macula in the convexity of the myopic staphyloma confirming the diagnosis of dome-shaped macula. Dome-shaped macula is a recently discovered entity, which may be responsible for a decrease in visual acuity in patients with high myopic posterior staphyloma. Ultrasound and optical coherence tomography are very helpful in making the diagnosis. Copyright © 2013. Published by Elsevier Masson SAS.

  16. Imaging actinic keratosis by high-definition optical coherence tomography. Histomorphologic correlation

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Norrenberg, Sarah; Jemec, Gregor B E

    2013-01-01

    With the continued development of non-invasive therapies for actinic keratosis such as PDT and immune therapies, the non-invasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography is a high-resolution imaging tool, with micrometre resolution in both...... transversal and axial directions, enable to visualize individual cells up to a depth of around 570 μm filling the imaging gap between conventional optical coherence tomography and reflectance confocal microscopy. We sought to determine the feasibility of detecting and grading of actinic keratosis...... by this technique using criteria defined for reflectance confocal microscopy compared to histology. In this pilot study, skin lesions of 17 patients with a histologically proven actinic keratosis were imaged by high-definition optical coherence tomography just before excision and images analysed qualitatively...

  17. Improvements in high energy computed tomography

    International Nuclear Information System (INIS)

    Burstein, P.; Krieger, A.; Annis, M.

    1984-01-01

    In computerized axial tomography employed with large relatively dense objects such as a solid fuel rocket engine, using high energy x-rays, such as a 15 MeV source, a collimator is employed with an acceptance angle substantially less than 1 0 , in a preferred embodiment 7 minutes of a degree. In a preferred embodiment, the collimator may be located between the object and the detector, although in other embodiments, a pre-collimator may also be used, that is between the x-ray source and the object being illuminated. (author)

  18. Spectral-domain optical coherence tomography of macula in myopia.

    Science.gov (United States)

    Choovuthayakorn, Janejit; Laowong, Taksaorn; Watanachai, Nawat; Patikulsila, Direk; Chaikitmongkol, Voraporn

    2016-06-01

    The aim of this study is to determine the associations between regional macular thickness and gender, age, axial length, and degree of myopia in young and middle-aged healthy myopic eyes. One hundred and seventy-one subjects with -0.5 diopters of myopia or worse underwent prospective macular thickness measurement by Spectralis spectral-domain optical coherence tomography. Subjects' mean age was 32.40 ± 8.25 years (range 18 to 49 years), with 45 % being male. The mean degree of myopia was -4.57 ± 3.52 diopters, with a mean axial length of 25.09 ± 1.67 mm. Multivariate regression analysis demonstrated significantly thicker central (mean 9.13 µm thicker) and inner subfields (mean 8.55 µm thicker) in males (P values were <0.001 and 0.002, respectively). In addition, in both genders, for each millimeter of increased axial length, the central subfield thickness increased by 2.11 µm, the inner subfield decreased by 2.25 µm, and the outer subfield decreased by 3.62 µm (P values were 0.010, <0.001, and <0.001, respectively). Factors including gender and axial length affect baseline regional macular thickness in young and middle-age myopic subjects. The central subfield and inner subfield were affected by both gender and axial length, while the outer subfield was affected only by axial length. The macular thickness of myopic subjects with macular disease should be interpreted in light of these factors.

  19. The deep structure of Axial Volcano

    Science.gov (United States)

    West, Michael Edwin

    The subsurface structure of Axial Volcano, near the intersection of the Juan de Fuca Ridge and the Cobb-Eickelberg seamount chain in the northeast Pacific, is imaged from an active source seismic experiment. At a depth of 2.25 to 3.5 km beneath Axial lies an 8 km x 12 km region of very low seismic velocities that can only be explained by the presence of magma. In the center of this magma storage chamber at 2--3.5 km below sea floor, the crust is at least 10--20% melt. At depths of 4--5 km there is evidence of additional low concentrations of magma (a few percent) over a larger area. In total, 5--11 km3 of magma are stored in the mid-crust beneath Axial. This is more melt than has been positively identified under any basaltic volcano on Earth. It is also far more than the 0.1--0.2 km3 emplaced during the 1998 eruption. The implied residence time in the magma reservoir of a few hundred to a few thousand years agrees with geochemical trends which suggest prolonged storage and mixing of magmas. The large volume of melt bolsters previous observations that Axial provides much of the material to create crust along its 50 km rift zones. A high velocity ring-shaped feature sits above the magma chamber just outside the caldera walls. This feature is believed to be the result of repeated dike injections from the magma body to the surface during the construction of the volcanic edifice. A rapid change in crustal thickness from 8 to 11 km within 15 km of the caldera implies focused delivery of melt from the mantle. The high flux of magma suggests that melting occurs deeper in the mantle than along the nearby ridge. Melt supply to the volcano is not connected to any plumbing system associated with the adjacent segments of the Juan de Fuca Ridge. This suggests that, despite Axial's proximity to the ridge, the Cobb hot spot currently drives the supply of melt to the volcano.

  20. Limb flexion-induced axial compression and bending in human femoropopliteal artery segments.

    Science.gov (United States)

    Poulson, William; Kamenskiy, Alexey; Seas, Andreas; Deegan, Paul; Lomneth, Carol; MacTaggart, Jason

    2018-02-01

    High failure rates of femoropopliteal artery (FPA) interventions are often attributed in part to severe mechanical deformations that occur with limb movement. Axial compression and bending of the FPA likely play significant roles in FPA disease development and reconstruction failure, but these deformations are poorly characterized. The goal of this study was to quantify axial compression and bending of human FPAs that are placed in positions commonly assumed during the normal course of daily activities. Retrievable nitinol markers were deployed using a custom-made catheter system into 28 in situ FPAs of 14 human cadavers. Contrast-enhanced, thin-section computed tomography images were acquired with each limb in the standing (180 degrees), walking (110 degrees), sitting (90 degrees), and gardening (60 degrees) postures. Image segmentation and analysis allowed relative comparison of spatial locations of each intra-arterial marker to determine axial compression and bending using the arterial centerlines. Axial compression in the popliteal artery (PA) was greater than in the proximal superficial femoral artery (SFA) or the adductor hiatus (AH) segments in all postures (P = .02). Average compression in the SFA, AH, and PA ranged from 9% to 15%, 11% to 19%, and 13% to 25%, respectively. The FPA experienced significantly more acute bending in the AH and PA segments compared with the proximal SFA (P < .05) in all postures. In the walking, sitting, and gardening postures, average sphere radii in the SFA, AH, and PA ranged from 21 to 27 mm, 10 to 18 mm, and 8 to 19 mm, whereas bending angles ranged from 150 to 157 degrees, 136 to 147 degrees, and 137 to 148 degrees, respectively. The FPA experiences significant axial compression and bending during limb flexion that occur at even modest limb angles. Moreover, different segments of the FPA appear to undergo significantly different degrees of deformation. Understanding the effects of limb flexion on axial compression and

  1. Evidence supporting the use of cone-beam computed tomography in orthodontics.

    Science.gov (United States)

    van Vlijmen, Olivier J C; Kuijpers, Mette A R; Bergé, Stefaan J; Schols, Jan G J H; Maal, Thomas J J; Breuning, Hero; Kuijpers-Jagtman, Anne Marie

    2012-03-01

    The authors conducted a systematic review of cone-beam computed tomography (CBCT) applications in orthodontics and evaluated the level of evidence to determine whether the use of CBCT is justified in orthodontics. The authors identified articles by searching the Cochrane Library, PubMed, MEDLINE, Embase, Scopus and Cumulative Index to Nursing and Allied Health Literature databases. They searched the articles' reference lists manually for additional articles and had no language limitations. They did not search the gray literature. Inclusion criteria were CBCT use in orthodontics and that the participants be human. The lowest level of evidence accepted for inclusion was a case series with five or more participants. The authors evaluated the studies' methodological quality according to 13 criteria related to study design, measurements and statistical analysis. The authors identified 550 articles, and 50 met the inclusion criteria. Study topics included temporary anchorage devices, cephalometry, combined orthodontic and surgical treatment, airway measurements, root resorption and tooth impactions, and cleft lip and palate. The methodological quality averaged 53 percent (range, 15-77 percent) of the maximum score. The authors found no high-quality evidence regarding the benefits of CBCT use in orthodontics. Limited evidence shows that CBCT offers better diagnostic potential, leads to better treatment planning or results in better treatment outcome than do conventional imaging modalities. Only the results of studies on airway diagnostics provided sound scientific data suggesting that CBCT use has added value. The additional radiation exposure should be weighed against possible benefits of CBCT, which have not been supported in the literature. In future studies, investigators should evaluate the effects of CBCT on treatment procedures, progression and outcome quantitatively.

  2. Blunt trauma of bone structures of the chest--computed tomography vs multidetector computed tomography.

    Science.gov (United States)

    Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana

    2013-08-01

    Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  3. Optical Coherence Tomography for the Assessment of Coronary Atherosclerosis and Vessel Response after Stent Implantation

    NARCIS (Netherlands)

    N. Gonzalo (Nieves)

    2010-01-01

    textabstractOptical Coherence Tomography (OCT) is a light-based imaging modality that can provide in vivo high-resolution images of the coronary artery with a level of resolution (axial 10-20 µm) ten times higher than intravascular ultrasound. The technique, uses low-coherent near infrarred light

  4. Doppler optical coherence microscopy and tomography applied to inner ear mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Page, Scott; Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Ghaffari, Roozbeh [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    2015-12-31

    While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

  5. Atlanto-axial malformation and instability in dogs with pituitary dwarfism due to an LHX3 mutation.

    Science.gov (United States)

    Voorbij, A M W Y; Meij, B P; van Bruggen, L W L; Grinwis, G C M; Stassen, Q E M; Kooistra, H S

    2015-01-01

    Canine pituitary dwarfism or combined pituitary hormone deficiency (CPHD) in shepherd dogs is associated with an LHX3 mutation and can lead to a wide range of clinical manifestations. Some dogs with CPHD have neurological signs that are localized to the cervical spine. In human CPHD, caused by an LHX3 mutation, anatomical abnormalities in the atlanto-axial (C1-C2) joint have been described. To evaluate the presence of atlanto-axial malformations in dogs with pituitary dwarfism associated with an LHX3 mutation and to investigate the degree of similarity between the atlanto-axial anomalies found in canine and human CPHD patients with an LHX3 mutation. Three client-owned Czechoslovakian wolfdogs and 1 client-owned German shepherd dog, previously diagnosed with pituitary dwarfism caused by an LHX3 mutation, with neurological signs indicating a cervical spinal disorder. Radiography, computed tomography, and magnetic resonance imaging of the cranial neck and skull, necropsy, and histology. Diagnostic imaging identified abnormal positioning of the dens axis and incomplete ossification of the suture lines between the ossification centers of the atlas with concurrent atlanto-axial instability and dynamic compression of the spinal cord by the dens axis. The malformations and aberrant motion at C1-C2 were confirmed at necropsy and histology. The atlanto-axial abnormalities of the dwarf dogs resemble those encountered in human CPHD patients with an LHX3 mutation. These findings suggest an association between the LHX3 mutation in dogs with CPHD and atlanto-axial malformations. Consequently, pituitary dwarfs should be monitored closely for neurological signs. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  6. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET/CT) Findings in an Unusual Case of Multiple Myeloma Presenting with a Large Extra-Axial Intracranial Mass.

    Science.gov (United States)

    Ayaz, Sevin; Ayaz, Ümit Yaşar

    2016-01-01

    We aimed to present unusual cranial FDG PET/CT findings of a 56-year-old female with multiple myeloma (MM). Plain CT images revealed a lytic lesion in the right parietal bone, filled with an oval-shaped, large, extra-axial, extradural, intracranial mass which measured 75×75×40 mm and had smooth borders. The right parietal lobe was compressed by the mass. The maximum standardized uptake value (SUV max ) of the mass lesion was 8.94 on FDG PET/CT images. Multiple lytic lesions with an increased uptake were also detected in other calvarial bones, in several vertebras and in the proximal left femur. After seven months, a control FDG PET/CT following radiotherapy and chemotherapy revealed almost complete regression of the right parietal extra-axial mass lesion. The number, size and metabolism of lytic lesions in other bones also decreased. FDG PET/CT was useful for an initial evaluation of MM lesions and was effective in monitoring the response of these lesions to therapy.

  7. Resolution of axial shear strain elastography

    International Nuclear Information System (INIS)

    Thitaikumar, Arun; Righetti, Raffaella; Krouskop, Thomas A; Ophir, Jonathan

    2006-01-01

    The technique of mapping the local axial component of the shear strain due to quasi-static axial compression is defined as axial shear strain elastography. In this paper, the spatial resolution of axial shear strain elastography is investigated through simulations, using an elastically stiff cylindrical lesion embedded in a homogeneously softer background. Resolution was defined as the smallest size of the inclusion for which the strain value at the inclusion/background interface was greater than the average of the axial shear strain values at the interface and inside the inclusion. The resolution was measured from the axial shear strain profile oriented at 45 0 to the axis of beam propagation, due to the absence of axial shear strain along the normal directions. The effects of the ultrasound system parameters such as bandwidth, beamwidth and transducer element pitch along with signal processing parameters such as correlation window length (W) and axial shift (ΔW) on the estimated resolution were investigated. The results show that the resolution (at 45 0 orientation) is determined by the bandwidth and the beamwidth. However, the upper bound on the resolution is limited by the larger of the beamwidth and the window length, which is scaled inversely to the bandwidth. The results also show that the resolution is proportional to the pitch and not significantly affected by the axial window shift

  8. Signatures for axial chromodynamics

    International Nuclear Information System (INIS)

    Pati, J.C.

    1978-07-01

    Within the context of basic left-right symmetry and the hypothesis of unification of weak, electromagnetic and strong forces at a mass level approximately equal to 10 4 -10 6 GeV, relatively light ''mass'' axial gluons, confined or liberated, must be postulated. The authors remark that the existence of such ''light'' axial gluons supplementing the familiar vector octet preserves the successes of QCD, both for deep inelastic processes and charmonium physics. Through the characteristic spin-spin force, generated by their exchange, they may even help resolve some of the discrepancies between vector QCD predictions and charmonium physics. The main remark of this note is that if colour is liberated, not only vector but also axial-vector gluons are produced in high-energy e - e + experiments, e.g. at PETRA and PEP, with fairly large cross-section. Distinctive decay modes of such liberated axial gluons are noted

  9. Dual-Source Swept-Source Optical Coherence Tomography Reconstructed on Integrated Spectrum

    Directory of Open Access Journals (Sweden)

    Shoude Chang

    2012-01-01

    Full Text Available Dual-source swept-source optical coherence tomography (DS-SSOCT has two individual sources with different central wavelengths, linewidth, and bandwidths. Because of the difference between the two sources, the individually reconstructed tomograms from each source have different aspect ratio, which makes the comparison and integration difficult. We report a method to merge two sets of DS-SSOCT raw data in a common spectrum, on which both data have the same spectrum density and a correct separation. The reconstructed tomographic image can seamlessly integrate the two bands of OCT data together. The final image has higher axial resolution and richer spectroscopic information than any of the individually reconstructed tomography image.

  10. A new strategy of axial power distribution control based on three axial offsets concept

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2009-01-01

    We have proposed a very simple control procedure for axial xenon oscillation control based on a characteristic trajectory. The trajectory is drawn by three offsets of power distributions, namely, AOp, AOi and AOx. They are defined as the offset of axial power distribution, the offset of the power distribution under which the current iodine distribution is obtained as the equilibrium and that for xenon distribution, respectively. When these offsets are plotted on X-Y plane for (AOp-AOx, AOi-AOx) the trajectory draws a quite characteristic ellipse (or an elliptic spiral). On the other hands, Constant Axial Offset Control (CAOC) procedure is adopted as axial power distribution control strategy during both base load and load following operations in domestic PWRs. In the previous paper, we have presented an innovative procedure of axial power distribution control during load following in PWRs based on this trajectory such that the AOp-AOx is to be controlled to zero when the value deviates the pre-determined limiting values. In this paper we propose a modified control strategy to get more stability of axial power distributions. In this strategy, we control the trajectory to be close to the major axis of the ellipse when the power distribution reaches the limiting values. In other words, the plot is not controlled only to reduce AOp-AOx but also AOi-AOx is taken into account at the same time. It is known that when the plot is controlled to the major axis, it means that the point gives the peak position of axial xenon oscillation. Therefore xenon oscillation will not increase its amplitude any more. Thus more stable axial power distribution control is attained. This kind of design concept is quite important especially for the future PWRs with elongated fuel length and longer core life. Because in a longer effective core and also the longer core life, it has been known that the stability of axial xenon oscillation becomes more unstable. In this paper, some simulation

  11. Dynamic light scattering optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Jiang, James Y; Zhu, Bo; Boas, David A

    2012-09-24

    We introduce an integration of dynamic light scattering (DLS) and optical coherence tomography (OCT) for high-resolution 3D imaging of heterogeneous diffusion and flow. DLS analyzes fluctuations in light scattered by particles to measure diffusion or flow of the particles, and OCT uses coherence gating to collect light only scattered from a small volume for high-resolution structural imaging. Therefore, the integration of DLS and OCT enables high-resolution 3D imaging of diffusion and flow. We derived a theory under the assumption that static and moving particles are mixed within the OCT resolution volume and the moving particles can exhibit either diffusive or translational motion. Based on this theory, we developed a fitting algorithm to estimate dynamic parameters including the axial and transverse velocities and the diffusion coefficient. We validated DLS-OCT measurements of diffusion and flow through numerical simulations and phantom experiments. As an example application, we performed DLS-OCT imaging of the living animal brain, resulting in 3D maps of the absolute and axial velocities, the diffusion coefficient, and the coefficient of determination.

  12. Modernity: A new axial (era culture?

    Directory of Open Access Journals (Sweden)

    Wolfgang Schluchter

    2017-10-01

    Full Text Available The proposition of an axial age, lasting roughly from 800 to 200 B.C. and occurring in major civilizations (China, India, Near East independent of each other, first introduced by Alfred Weber and Karl Jaspers, then further developed by Robert Bellah and S. N. Eisenstadt among others, implied from the outset the question whether there has been a second axial age, leading to modernity, and if so, whether this second axial age consists in a secularization of the achievements of the first axial age. In this article it is argued that the notion of a second axial age is meaningful, but that the emergence of modernity can›t be accounted for in terms of secularization of the achievements of the first axial age. Rather, a new axial principle was institutionalized which separates the modern from the premodern world. This new principle is spelled out with reference to Hans Blumenberg, Charles Taylor and especially Max Weber. The emphasis is on the dialectics of disenchantment and the place of religion in a secular age

  13. Coexistence of axial spondyloarthritis and thromboangiitis obliterans in a young woman

    Directory of Open Access Journals (Sweden)

    G. Lopalco

    2015-06-01

    Full Text Available A peculiar coexistence of axial spondyloarthritis and ischemia of the feet and the fourth finger of the left hand in a young woman, who was a heavy smoker, is discussed in this report. This picture was considered within the context of thromboangiitis obliterans. Positivity of anti-nuclear antibodies and mild elevation of inflammatory parameters were noted. Computed tomography angiograms of upper and lower limbs showed luminal narrowing and occlusion of the left humeral, left anterior/posterior tibial and right anterior tibial arteries. Daily iloprost perfusions were started, and smoking cessation was strongly recommended. Coldness and rest pain in the distal extremities improved within a few weeks. The possibility that spondyloarthritis might precede the clinical picture of thromboangiitis obliterans should be considered in heavy smokers.

  14. Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

    Science.gov (United States)

    Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki

    2009-12-01

    To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P renal vascular anatomy before laparoscopic donor nephrectomy.

  15. Diagnosis of cholesteatoma by high resolution computed tomography

    International Nuclear Information System (INIS)

    Kakitsubata, Yousuke; Kakitsubata, Sachiko; Ogata, Noboru; Asada, Keiko; Watanabe, Katsushi; Tohno, Tetsuya; Makino, Kohji

    1988-01-01

    Three normal volunteers and 57 patients with cholesteatoma were examined by high resolution computed tomography. Serial sections were made through the temporal bone at the nasaly inclined position of 30 degree to the orbitomeatal line (semiaxial plane ; SAP). The findings of temporal bone structures in normal subjects were evaluated in SAP and axial plane (OM). Although the both planes showed good visualization, SAP showed both the eustachian tube and tympanic cavity in one slice. In cholesteatoma soft tissue masses in the tympanic cavity, mastoid air cells and Eustachian tube were demonstrated clearly by SAP. (author)

  16. Experimental Studies on Strength Behaviour of Notched Glass/Epoxy Laminated Composites under Uni-axial and Bi-axial Loading

    Science.gov (United States)

    Guptha, V. L. Jagannatha; Sharma, Ramesh S.

    2017-11-01

    The use of FRP composite materials in aerospace, aviation, marine, automotive and civil engineering industry has increased rapidly in recent years due to their high specific strength and stiffness properties. The structural members contrived from such composite materials are generally subjected to complex loading conditions and leads to multi-axial stress conditions at critical surface localities. Presence of notches, much required for joining process of composites, makes it further significant. The current practice of using uni-axial test data alone to validate proposed material models is inadequate leading to evaluation and consideration of bi-axial test data. In order to correlate the bi-axial strengths with the uni-axial strengths of GFRP composite laminates in the presence of a circular notch, bi-axial tests using four servo-hydraulic actuators with four load cells were carried out. To determine the in-plane strength parameters, bi-axial cruciform test specimen model was considered. Three different fibre orientations, namely, 0°, 45°, and 90° are considered with a central circular notch of 10 mm diameter in the present investigation. From the results obtained, it is observed that there is a reduction in strength of 5.36, 2.41 and 13.92% in 0°, 45°, and 90° fibre orientation, respectively, under bi-axial loading condition as compared to that of uni-axial loading in laminated composite.

  17. In situ evidence of mineral physical protection and carbon stabilization revealed by nanoscale 3-D tomography

    Science.gov (United States)

    Weng, Yi-Tse; Wang, Chun-Chieh; Chiang, Cheng-Cheng; Tsai, Heng; Song, Yen-Fang; Huang, Shiuh-Tsuen; Liang, Biqing

    2018-05-01

    An approach for nanoscale 3-D tomography of organic carbon (OC) and associated mineral nanoparticles was developed to illustrate their spatial distribution and boundary interplay, using synchrotron-based transmission X-ray microscopy (TXM). The proposed 3-D tomography technique was first applied to in situ observation of a laboratory-made consortium of black carbon (BC) and nanomineral (TiO2, 15 nm), and its performance was evaluated using dual-scan (absorption contrast and phase contrast) modes. This novel tool was then successfully applied to a natural OC-mineral consortium from mountain soil at a spatial resolution of 60 nm, showing the fine structure and boundary of OC, the distribution of abundant nano-sized minerals, and the 3-D organo-mineral association in situ. The stabilization of 3500-year-old natural OC was mainly attributed to the physical protection of nano-sized iron (Fe)-containing minerals (Fe oxyhydroxides including ferrihydrite, goethite, and lepidocrocite), and the strong organo-mineral complexation. In situ evidence revealed an abundance of mineral nanoparticles, in dense thin layers or nano-aggregates/clusters, instead of crystalline clay-sized minerals on or near OC surfaces. The key working minerals for C stabilization were reactive short-range-order (SRO) mineral nanoparticles and poorly crystalline submicron-sized clay minerals. Spectroscopic analyses demonstrated that the studied OC was not merely in crisscross co-localization with reactive SRO minerals; there could be a significant degree of binding between OC and the minerals. The ubiquity and abundance of mineral nanoparticles on the OC surface, and their heterogeneity in the natural environment may have been severely underestimated by traditional research approaches. Our in situ description of organo-mineral interplay at the nanoscale provides direct evidence to substantiate the importance of mineral physical protection for the long-term stabilization of OC. This high-resolution 3-D

  18. Three-dimensional cranio-facial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Muccelli, R; Stagul, F; Pozzi Muccelli, F; Zuiani, C; Smathers, R

    1986-01-01

    Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

  19. Three-dimensional cranio-facial computed tomography

    International Nuclear Information System (INIS)

    Pozzi Muccelli, R.; Stagul, F.; Pozzi Muccelli, F.; Zuiani, C.; Smathers, R.

    1986-01-01

    Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy

  20. Wigner tomography of multispin quantum states

    Science.gov (United States)

    Leiner, David; Zeier, Robert; Glaser, Steffen J.

    2017-12-01

    We study the tomography of multispin quantum states in the context of finite-dimensional Wigner representations. An arbitrary operator can be completely characterized and visualized using multiple shapes assembled from linear combinations of spherical harmonics [A. Garon, R. Zeier, and S. J. Glaser, Phys. Rev. A 91, 042122 (2015), 10.1103/PhysRevA.91.042122]. We develop a general methodology to experimentally recover these shapes by measuring expectation values of rotated axial spherical tensor operators and provide an interpretation in terms of fictitious multipole potentials. Our approach is experimentally demonstrated for quantum systems consisting of up to three spins using nuclear magnetic resonance spectroscopy.

  1. Axial movements are relatively preserved with respect to limb movements in aphasic patients.

    Science.gov (United States)

    Hanlon, R E; Mattson, D; Demery, J A; Dromerick, A W

    1998-12-01

    Apraxia is commonly manifested during the acute stage following left hemisphere cerebrovascular accident and typically co-occurs with aphasia. We examined 30 acute stroke patients with aphasia and apraxia in order to determine if such patients show evidence of preservation of selective subclasses of movements. Although Geschwind noted the preservation of axial movements to command in aphasic apraxic patients, his views were subsequently refuted. However, we found that aphasic apraxic patients of varying degrees of severity, including patients with global aphasia, showed relative preservation of axial movements to command and imitation. Theoretical interpretations and implications for acute neurologic rehabilitation are discussed.

  2. Value of computed tomography for the diagnosis and pre and post-treatment workup of aortic aneurysms. Comparison with angiographic findings. A report of data in 112 cases

    International Nuclear Information System (INIS)

    Senac, J.P.; Giron, J.; Ovchinnikoff, S.; Mourre, P.; Joffre, P.; Mary, H.; Novati, J.P.

    1987-01-01

    The authors report that CT scan provided decisive or complementary data, as compared to angiography, in 112 cases of aortic aneurysm. CT scan thus emerges as a useful tool. The inadequate angiographies were either nearly normal, or showed evidence that pointed to total arterial occlusion whose thrombotic and aneurysmal nature was demonstrated only upon computed tomography; CT scan proved irreplaceable for evaluating prostheses and postoperative complications. The axial transverse plane of CT sections explains why computed tomography is so informative: the channel, thrombosis, wall and peri-adventicia (fibrosis, fissuration) are visible successively from the center to the periphery. In the authors' opinion, the pretreatment evaluation of an aortic aneurysm should include a CT angioscan in addition to an angiography as the two procedures complement one another. After surgery, CT scan is even more widely indicated. CT scan is the primary procedure for controlling a prosthesis and often makes other investigations unnecessary [fr

  3. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    Science.gov (United States)

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (pdiabetes duration (pdiabetic retinopathy compared to control subjects (pdiabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  4. The space-time outside a source of gravitational radiation: the axially symmetric null fluid

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, L. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Universidad de Salamanca, Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain); Di Prisco, A. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Ospino, J. [Universidad de Salamanca, Departamento de Matematica Aplicada and Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain)

    2016-11-15

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric space-times. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the 1 + 3 formalism. (orig.)

  5. Stall inception and warning in a single-stage transonic axial compressor with axial skewed slot casing treatment

    International Nuclear Information System (INIS)

    Lim, Byeung Jun; Kwon, Se Jin; Park, Tae Choon

    2014-01-01

    Characteristic changes in the stall inception in a single-stage transonic axial compressor with an axial skewed slot casing treatment were investigated experimentally. A rotating stall occurred intermittently in a compressor with an axial skewed slot, whereas spike-type rotating stalls occurred in the case of smooth casing. The axial skewed slot suppressed stall cell growth and increased the operating range. A mild surge, the frequency of which is the Helmholtz frequency of the compressor system, occurred with the rotating stall. The irregularity in the pressure signals at the slot bottom increased decreasing flow rate. An autocorrelation-based stall warning method was applied to the measured pressure signals. Results estimate and warn against the stall margin in a compressor with an axial skewed slot.

  6. Notchless is required for axial skeleton formation in mice.

    Directory of Open Access Journals (Sweden)

    Sarah Beck-Cormier

    Full Text Available Maintenance of cell survival is essential for proper embryonic development. In the mouse, Notchless homolog 1 (Drosophila (Nle1 is instrumental for survival of cells of the inner cell mass upon implantation. Here, we analyze the function of Nle1 after implantation using the Meox2(tm1(creSor mouse that expresses the Cre recombinase specifically in the epiblast at E5.5. First, we find that NLE1 function is required in epiblast cells, as Nle1-deficient cells are rapidly eliminated. In this report, we also show that the Meox2(Cre transgene is active in specific tissues during organogenesis. In particular, we detect high Cre expression in the vertebral column, ribs, limbs and tailbud. We took advantage of this dynamic expression profile to analyze the effects of inducing mosaic deletion of Nle1 in the embryo. We show that Nle1 deletion in this context, results in severe developmental anomalies leading to lethality at birth. Mutant embryos display multiple developmental defects in particular during axial skeletal formation. We also provide evidence that axial defects are due to an increase in apoptotic cell death in the somite at E9.5. These data demonstrate an essential role for Nle1 during organogenesis and in particular during axial development.

  7. Notchless is required for axial skeleton formation in mice.

    Science.gov (United States)

    Beck-Cormier, Sarah; Escande, Marie; Souilhol, Céline; Vandormael-Pournin, Sandrine; Sourice, Sophie; Pilet, Paul; Babinet, Charles; Cohen-Tannoudji, Michel

    2014-01-01

    Maintenance of cell survival is essential for proper embryonic development. In the mouse, Notchless homolog 1 (Drosophila) (Nle1) is instrumental for survival of cells of the inner cell mass upon implantation. Here, we analyze the function of Nle1 after implantation using the Meox2(tm1(cre)Sor) mouse that expresses the Cre recombinase specifically in the epiblast at E5.5. First, we find that NLE1 function is required in epiblast cells, as Nle1-deficient cells are rapidly eliminated. In this report, we also show that the Meox2(Cre) transgene is active in specific tissues during organogenesis. In particular, we detect high Cre expression in the vertebral column, ribs, limbs and tailbud. We took advantage of this dynamic expression profile to analyze the effects of inducing mosaic deletion of Nle1 in the embryo. We show that Nle1 deletion in this context, results in severe developmental anomalies leading to lethality at birth. Mutant embryos display multiple developmental defects in particular during axial skeletal formation. We also provide evidence that axial defects are due to an increase in apoptotic cell death in the somite at E9.5. These data demonstrate an essential role for Nle1 during organogenesis and in particular during axial development.

  8. Characterization of Multiflux Axial Compressors

    International Nuclear Information System (INIS)

    Brasnarof, Daniel; Kyung Kyu-Hyung; Rivarola, Martin; Gonzalez Jose; Florido, Pablo; Orellano, Pablo; Bergallo, Juan

    2003-01-01

    In the present work the results of analytical models of performance are compared with experimental data acquired in the multi flux axial compressor test facility, built in The Pilcaniyeu Technological Complex for the SIGMA project.We describe the experimental circuit and the data of the dispersion inside the axial compressor obtained using a tracer gas through one of the annular inlets.The attained results can be used to validate the design code for the multi flux axial compressors and SIGMA industrial plant

  9. Conventional X-ray examination and computed tomography in inflammatory rheumatic diseases

    International Nuclear Information System (INIS)

    Lingg, G.

    1996-01-01

    Plain-film radiography is an important and basic element in the assessment of inflammatory rheumatic diseases. Its various uses include assessment of inflammatory osseous destruction and the activity of inflammatory changes. Furthermore, the inflammatory collateral phenomena can indicate an acute clinical phase, and the articular soft tissue swelling and tenosynovitis are shown directly and indirectly very clearly. On the other hand, high-resolution computed tomography is very capable of showing cortical structures of bone complementary to MR. In some special clinical questions and anatomical regions, especially the axial skeleton, it delivers information of high specifity, partly for definitive diagnosis and partly for planning surgical procedures. The assessment of changes in the sacroiliac joints, sternoclavicular joints and craniocervical junction are domains of computed tomography. (orig.) [de

  10. Value of computed tomography for the diagnosis and pre and post-treatment work-up of aortic aneurysms. Comparison with angiographic findings. A report of data in 112 cases

    International Nuclear Information System (INIS)

    Senac, J.P.; Giron, J.; Ovchinnickoff, S.; Mourre, P.; Joffre, P.; Mary, H.; Novati, J.P.

    1986-01-01

    The authors report that CT scan provided decisive or complementary data, as compared to angiography, in 112 cases of aortic aneurysm. CT scan thus emerges as an useful tool. The inadequate angiographies were either nearly normal, or showed evidence that pointed to total arterial occlusion whose thrombotic and aneurysmal nature was demonstrated only upon computed tomography; CT scan proved irreplaceable for evaluating prostheses and postoperative complications. The axial transverse plane of CT sections explains why computed tomography is so informative: the channel, thrombosis, wall and peri-adventicia (fibrosis, fissuration) are visible successively from the center to the periphery. In the authors' opinion, the pretreatment evaluation of an aortic aneurysm should include a CT angioscan in addition to an angiography as the two procedures complement one another. After surgery, CT scan is even more widely indicated. CT scan is the primary procedure for controlling a prosthesis and often makes other investigations unnecessary [fr

  11. Stability management of high speed axial flow compressor stage through axial extensions of bend skewed casing treatment

    Directory of Open Access Journals (Sweden)

    DilipkumarBhanudasji Alone

    2016-09-01

    Full Text Available This paper presents the experimental results to understand the performance of moderately loaded high speed single stage transonic axial flow compressor subjected to various configurations of axial extensions of bend skewed casing treatment with moderate porosity. The bend skewed casing treatment of 33% porosity was coupled with rectangular plenum chamber of depth equal to the slots depth. The five axial extensions of 20%, 40%, 60%, 80% and 100% were used for the experimental evaluations of compressor performance. The main objective was to identify the optimum extension of the casing treatment with reference to rotor leading edge which results in maximum stall margin improvements with minimum loss in the stage efficiency. At each axial extension the compressor performance is distinctive. The improvement in the stall margin was very significant at some axial extensions with 4%–5% penalty in the stage efficiency. The compressors stage shows recovery in terms of efficiency at lower axial extensions of 20% and 40% with increase in the peak stage efficiency. Measurements of flow parameters showed the typical behaviors at near stall flow conditions. Hot wire sensor was placed at the rotor upstream in the tip region to capture the oscillations in the inlet axial and tangential velocities at stall conditions. In the absence of casing treatment the compressor exhibit abrupt stall with very high oscillations in the inlet axial and tangential velocity of the flow. The extents of oscillations reduce with bend skewed casing treatment. Few measurements were also performed in the plenum chamber and salient results are presented in this paper.

  12. Blunt trauma of bone structures of the chest: Computed tomography vs multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Petrović Kosta

    2013-01-01

    Full Text Available Background/Aim. Computerized tomography (CT, especially multidetector CT (MDCT, has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR. Methods. This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists independently and separately described the findings for 5-mmthick axial CT slices (5 mm CT as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thinslice examination together which was ultimately considered as a real, true finding. Results. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05. Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05 in favor of better display of injury by MDCT examination. Conclusion. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  13. Electric capacitance tomography and two-phase flow for the nuclear reactor safety analysis

    International Nuclear Information System (INIS)

    Lee, Jae Young

    2008-01-01

    Recently electric capacitance tomography has been developed to be used in the analysis of two-phase flow. Although its electric field is not focused as the hard ray tomography such as the X-ray or gamma ray, its convenience of easy access to the system and easy maintenance due to no requirement of radiation shielding benefits us in its application in the two-phase flow study, one of important area in the nuclear safety analysis. In the present paper, the practical technologies in the electric capacitance tomography are represented in both parts of hardware and software. In the software part, both forward problem and inverse problem are discussed and the method of regularization. In the hardware part, the brief discussion of the electronics circuits is made which provides femto farad resolution with a reasonable speed (150 frame/sec for 16 electrodes). Some representative ideal cases are studied to demonstrate its potential capability for the two-phase flow analysis. Also, some variations of the tomography such as axial tomography, and three dimensional tomography are discussed. It was found that the present ECT is expected to become a useful tool to understand the complicated three dimensional two-phase flow which may be an important feature to be equipped by the safety analysis codes. (author)

  14. On renormalization of axial anomaly

    International Nuclear Information System (INIS)

    Efremov, A.V.; Teryaev, O.V.

    1989-01-01

    It is shown that multiplicative renormalization of the axial singlet current results in renormalization of the axial anomaly in all orders of perturbation theory. It is a necessary condition for the Adler - Bardeen theorem being valid. 10 refs.; 2 figs

  15. Computed tomography in the diagnosis of fractures of the maxillofacial area

    International Nuclear Information System (INIS)

    Angelova, I.; Yordanov, G.; Sirakov, V.; Velkova, K.

    2013-01-01

    Computed tomography (CT) is the current method of study in maxillofacial region, which produces cross-sectional images of a specific area. There are still questions about methodology and radiation exposure. The aim of the present study is to evaluate the CT in diagnosis of fractures in maxillofacial region. 42 patients with traumatic injuries to the facial skeleton are examined. Fractures of maxilla are occurring in 14.6 % of patients with traumatic diseases. Fractures of maxilla and zygomatic bone are found in 29.3 percent of the traumatic event. Isolated nasal bone fracture is observed in 2.4% of ail fractures. Compound fractures constitute 17.1% of the tested fractures. This group of patients are positioned at second place in frequency. Mandibular fractures ranked first in frequency -36.6% of all traumatic lesions. The methods include: 1. Slice computed tomography in the axial and coronary projection 2. Spiral CT in axial projection and coronary one. 3. Cone Beam Computed Tomography. CT diagnosis is based on an analysis of all the images. It must comply with the data from other studies. When analyzing the results we found that the percentage of patients with primary diagnosis of fractured upper jaw is 11 %, while CT diagnosis of this percentage increases to 16%. The percentage of patients with primary diagnosis fracture of mandibula and CT diagnosis is almost identical. In the present study, 3D and CT have similar results in the detection of fractures. Three-dimensional images dearly show the spatial anatomy of the face, the presence of fragments, as well as monitoring of fracture lines. Key words; Fractures. Maxillofacial Area. CT

  16. High temperature co-axial winding transformers

    Science.gov (United States)

    Divan, Deepakraj M.; Novotny, Donald W.

    1993-01-01

    The analysis and design of co-axial winding transformers is presented. The design equations are derived and the different design approaches are discussed. One of the most important features of co-axial winding transformers is the fact that the leakage inductance is well controlled and can be made low. This is not the case in conventional winding transformers. In addition, the power density of co-axial winding transformers is higher than conventional ones. Hence, using co-axial winding transformers in a certain converter topology improves the power density of the converter. The design methodology used in meeting the proposed specifications of the co-axial winding transformer specifications are presented and discussed. The final transformer design was constructed in the lab. Co-axial winding transformers proved to be a good choice for high power density and high frequency applications. They have a more predictable performance compared with conventional transformers. In addition, the leakage inductance of the transformer can be controlled easily to suit a specific application. For space applications, one major concern is the extraction of heat from power apparatus to prevent excessive heating and hence damaging of these units. Because of the vacuum environment, the only way to extract heat is by using a cold plate. One advantage of co-axial winding transformers is that the surface area available to extract heat from is very large compared to conventional transformers. This stems from the unique structure of the co-axial transformer where the whole core surface area is exposed and can be utilized for cooling effectively. This is a crucial issue here since most of the losses are core losses.

  17. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  18. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  19. Subfoveal choroidal thickness measured by Cirrus HD optical coherence tomography in myopia

    Directory of Open Access Journals (Sweden)

    Li-Li Chen

    2014-09-01

    Full Text Available ATM: To measure the subfoveal choroidal thickness(SFCTin myopia using Cirrus HD optical coherence tomography(OCT, and to explore the relationship between the SFCT, axial length and myopic refractive spherical equivalent.METHODS: One-hundred thirty-three eyes of 70 healthy volunteers were recruited, and were divided into emmetropia group, low-degree myopia, middle-degree myopia and high-degree myopia group. SFCT were measured by Cirrus HD OCT, and the relationship between the SFCT, axial length and myopic refractive spherical equivalent were evaluated.RESULTS: 1Average SFCT was(275.91±55.74μm in normals, that in emmetropia group, low-degree myopia, middle-degree myopia and high-degree myopia group were(290.03±34.82μm,(287.64±51.51μm,(274.95±56.83μm,(248.37±67.98μm; 2the SFCT of high-degree myopia group was significant thinner than that of emmetropia group(PPPCONCLUSION: the SFCT is inversely correlated with increasing axial length and myopic refractive error.

  20. Origin of axial current in scyllac

    International Nuclear Information System (INIS)

    Sugisaki, K.

    1975-12-01

    The origin of the axial current observed in Scyllac (a high beta stellarator experiment) is discussed. A shaped coil and/or helical winding produce rotational transform which links magnetic lines of force to the plasma column and the axial current is induced electromagnetically. This phenomenon is inherent in a pulsed high-beta stellarator. The rotational transform produced by the induced axial current is much smaller than that associated with the l = 1, 0 equilibrium fields. The effect of the axial current on the equilibrium and stability of the plasma column is thus small. It is also shown that the magnetic field shear near a plasma surface is very strong

  1. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  2. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  3. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  4. Computed tomography in the foramen magnum and high cervical cord lesion

    Energy Technology Data Exchange (ETDEWEB)

    Isu, T.; Ito, T.; Iwasaki, Y.; Tsuru, M. (Hokkaido Univ., Sapporo (Japan). School of Medicine); Kitaoka, K.

    1981-10-01

    The value of computed tomography in the spine and spinal cord disease recently has been well documented. However, little attention is made to the role of computed tomography in foramen magnum and high cervical cord lesion. We report 16 cases of the foramen magnum and high cervical cord lesion. Method: Either EMI Head Scanner, CT 1010 (slice thickness 10 mm) or EMI Whole Body Scanner, CT 5005 (slice thickness 13 mm) was used. In 9 cases enhanced CT with intravenous injection of contrast medium was performed. Eleven cases received intrathecal injection of metrizamide. Materials: 1) control group without cervical pathology 70 cases, 2) spinal cord tumor 6 cases, 3) atlanto-axial dislocation 6 cases, 4) Chiari malformation (type 1) 3 cases, 5) spinal foreign body (acupuncture needle) 1 case. Results: 1. plain CT. 1) In control group without cervical pathology the cervical cord at C/sub 1/ level was seen as area surrounded by ring of subarachnoid space. 2) In 14 cases except for 1 case of atlanto-axial dislocation and 1 case of spinal foreign body identification of the cervical cord at C/sub 1/ level was impossible. 3) CT was of diagnostic value in detecting altanto-axial dislocation and spinal foreign body. 2. enhanded CT. Meningioma and neurinoma showed positive contrast enhancement. However, astrocytoma and herniated cerebellar tonsils were not detectable. 3. CT metrizamide myelography visualized the subarachnoid space and made it possible to localize the lesion in the spinal canal in relation to the spinal cord. Conclusion: Attention should be given to plain CT finding at C/sub 1/ level in diagnosis of foramen magnum and high cervical cord lesion. If identification of cervical cord at C/sub 1/ level is impossible, it is suspected that subarachnoid space is blocked by the lesion, and enhanced CT and CT metrizamide myelography must be performed.

  5. Computed tomography in the foramen magnum and high cervical cord lesion

    International Nuclear Information System (INIS)

    Isu, Toyohiko; Ito, Terufumi; Iwasaki, Yoshnobu; Tsuru, Mitsuo; Kitaoka, Kenichi.

    1981-01-01

    The value of computed tomography in the spine and spinal cord disease recently has been well documented. However, little attention is made to the role of computed tomography in foramen magnum and high cervical cord lesion. We report 16 cases of the foramen magnum and high cervical cord lesion. Method: Either EMI Head Scanner, CT 1010 (slice thickness 10 mm) or EMI Whole Body Scanner, CT 5005 (slice thickness 13 mm) was used. In 9 cases enhanced CT with intravenous injection of contrast medium was performed. Eleven cases received intrathecal injection of metrizamide. Materials: 1) control group without cervical pathology 70 cases, 2) spinal cord tumor 6 cases, 3) atlanto-axial dislocation 6 cases, 4) Chiari malformation (type 1) 3 cases, 5) spinal foreign body (acupuncture needle) 1 case. Results: 1. plain CT. 1) In control group without cervical pathology the cervical cord at C 1 level was seen as area surrounded by ring of subarachnoid space. 2) In 14 cases except for 1 case of atlanto-axial dislocation and 1 case of spinal foreign body identification of the cervical cord at C 1 level was impossible. 3) CT was of diagnostic value in detecting altanto-axial dislocation and spinal foreign body. 2. enhanded CT. Meningioma and neurinoma showed positive contrast enhancement. However, astrocytoma and herniated cerebellar tonsils were not detectable. 3. CT metrizamide myelography visualized the subarachnoid space and made it possible to localize the lesion in the spinal canal in relation to the spinal cord. Conclusion: Attention should be given to plain CT finding at C 1 level in diagnosis of foramen magnum and high cervical cord lesion. If identification of cervical cord at C 1 level is impossible, it is suspected that subarachnoid space is blocked by the lesion, and enhanced CT and CT metrizamide myelography must be performed. (author)

  6. Extended Hamiltonian formalism of the pure space-like axial gauge Schwinger model

    International Nuclear Information System (INIS)

    Nakawaki, Yuji; Mccartor, Gary

    2001-01-01

    We demonstrate that pure space-like axial gauge quantizations of gauge fields can be constructed in ways that are free from infrared divergences. To do so, we must extend the Hamiltonian formalism to include residual gauge fields. We construct an operator solution and an extended Hamiltonian of the pure space-like axial gauge Schwinger model. We begin by constructing an axial gauge formation in auxiliary coordinates, x μ =(x + , x - ), where x + =x 0 sinθ + x 1 cosθ, x - =x 0 cosθ - x 1 sinθ, and we take A=A 0 cosθ + A 1 sin θ=0 as the gauge fixing condition. In the region 0 - as the evolution parameter and construct a traditional canonical formulation of the temporal gauge Schwinger model in which residual gauge fields dependent only on x + are static canonical variables. Then we extrapolate the temporal gauge operator solution into the axial region, π / 4 + is taken as the evolution parameter. In the axial region we find that we have to take the representation of the residual gauge fields realizing the Mandelstam-Leibbrandt prescription in order for the infrared divergences resulting from (∂) -1 to be canceled by corresponding ones resulting from the inverse of the hyperbolic Laplace operator. We overcome the difficulty of constructing the Hamiltonian for the residual gauge fields by employing McCartor and Robertson's method, which gives us a term integrated over x - =constant. Finally, by taking the limit θ→π / 2 - 0, we obtain an operator solution and the Hamiltonian of the axial gauge (Coulomb gauge) Schwinger model in ordinary coordinates. That solution includes auxiliary fields, and the representation space is of indefinite metric, providing further evidence that 'physical' gauges are no more physical than 'unphysical' gauges. (author)

  7. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  8. Beam Hardening Artifacts: Comparison between Two Cone Beam Computed Tomography Scanners

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2012-04-01

    Full Text Available Background and aims. At present, cone beam computed tomography (CBCT has become a substitute for computed tomography (CT in dental procedures. The metallic materials used in dentistry can produce artifacts due to the beam hardening phenomenon. These artifacts decrease the quality of images. In the present study, the number of artifacts as a result of beam hardening in the images of dental implants was compared between two NewTom VG and Planmeca Promax 3D Max CBCT machines. Materials and methods. An implant drilling model was used in the present study. The implants (Dentis were placed in the canine, premolar and molar areas. Scanning procedures were carried out by two CBCT machines. The corresponding sections (coronal and axial of the implants were evaluated by two radiologists. The number of artifacts in each image was determined using the scale provided. Mann-Whitney U test was used for two-by-two comparisons at a significance level of P<0.05. Results. There were statistically significant differences in beam hardening artifacts in axial and coronal sections between the two x-ray machines (P<0.001, with a higher quality in the images produced by the NewTom VG. Conclusion. Given the higher quality of the images produced by the NewTom VG x-ray machine, it is recommended for imaging of patients with extensive restorations, multiple prostheses or previous implant treatments.

  9. Hybrid Gama Emission Tomography (HGET): FY16 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Erin A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, Leon E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wittman, Richard S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Campbell, Luke W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deshmukh, Nikhil S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zalavadia, Mital A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Batie, Margo A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-01

    Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.

  10. Evidence for a caudate role in aphasia from FDG positron emission tomography

    International Nuclear Information System (INIS)

    Metter, E.J.; Riege, W.H.; Hanson, W.R.; Phelps, M.; Kuhl, D.E.

    1982-01-01

    In a recent study correlations between language function and regional glucose metabolism from FDG positron computed tomography were examined. Caudate metabolism correlated with PICA speaking and comprehension factors, as well as BDAE mean writing and reading scores. To identify the language function implicated with caudate metabolism in these eleven patients, twenty subtests making up these two PICA factors and mean BDAE scores were correlated to caudate metabolism. Also a principle components analysis on the twenty subtests identified three factors, only one of which correlated with caudate metabolism. Evidence was found that the caudate has a functional relationship to recognition or motor planning of simple and overlearned materials. This involved simple syntax, low levels of abstraction, identification or sequencing of phonetic and semantic material. This role appeared related to but independent of Broca and frontal lobe function, and may involve the focusing of cortical functions, by allowing two or more regions to interact together

  11. Vector and axial constants of the baryon decuplet

    International Nuclear Information System (INIS)

    Belyaev, V.M.; Blok, B.Y.; Kogan, Y.I.

    1985-01-01

    On the basis of the QCD sum rules for the polarization operator in external axial and vector fields we determine the vector and axial transition constants in the 3/2 + baryon decuplet. We show that the renormalization of the axial constant is due to the interaction of the external axial field with the quark condensate

  12. Axial gap rotating electrical machine

    Science.gov (United States)

    None

    2016-02-23

    Direct drive rotating electrical machines with axial air gaps are disclosed. In these machines, a rotor ring and stator ring define an axial air gap between them. Sets of gap-maintaining rolling supports bear between the rotor ring and the stator ring at their peripheries to maintain the axial air gap. Also disclosed are wind turbines using these generators, and structures and methods for mounting direct drive rotating electrical generators to the hubs of wind turbines. In particular, the rotor ring of the generator may be carried directly by the hub of a wind turbine to rotate relative to a shaft without being mounted directly to the shaft.

  13. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  14. Axial gap formation in P.W.R. fuel pins

    International Nuclear Information System (INIS)

    Roberts, G.; Jones, K.W.

    1978-07-01

    The potential mechanisms of axial gap formation in PWR fuel pins are examined analytically and also using evidence from post-irradiation examination (p.i.e.) investigation. It is concluded that fuel and cladding cannot remain in contact during densification and so the settling of of the fuel stack, which forms the gaps, must be prevented by such things as asperities in the cladding, fuel chips or tilted pellets. Examples from the p.i.e. examination programme are used to support this conclusion. (author)

  15. Electric machines with axial magnetic flux

    Science.gov (United States)

    Nuca, I.; Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Turcanu, A.

    2018-01-01

    The paper contains information on the performance of axial machines compared to cylindrical ones. At the same time, various constructive schemes of synchronous electromechanical converters with permanent magnets and asynchronous with short-circuited rotor are presented. In the developed constructions, the aim is to maximize the usage of the material of the stator windings. The design elements of the axial machine magnetic system are presented. The FEMM application depicted the array of the magnetic field of an axial machine.

  16. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  17. Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Segars, W. P.; Rybicki, K.; Norris, Hannah; Samei, E.; Frush, D.

    2014-01-01

    Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r 2 = 0.382, mean r 2 = 0.236). Similar trends were found for organ midpoint versus height (max r 2 = 0.439, mean r 2 = 0.200) and for organ volume versus height (max r 2 = 0.410, mean r 2 = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r 2 -values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r 2 = 0.842, mean r 2 = 0.790; max r 2 = 0.949, mean r 2 = 0.894; and max r 2 = 0.870, mean r 2 = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r 2 = 0.772, mean r 2 = 0.562) and for organ

  18. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

    Science.gov (United States)

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J S; Kraus, Martin F; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E; Fujimoto, James G

    2013-07-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated.

  19. Radial and axial compression of pure electron

    International Nuclear Information System (INIS)

    Park, Y.; Soga, Y.; Mihara, Y.; Takeda, M.; Kamada, K.

    2013-01-01

    Experimental studies are carried out on compression of the density distribution of a pure electron plasma confined in a Malmberg-Penning Trap in Kanazawa University. More than six times increase of the on-axis density is observed under application of an external rotating electric field that couples to low-order Trivelpiece-Gould modes. Axial compression of the density distribution with the axial length of a factor of two is achieved by controlling the confining potential at both ends of the plasma. Substantial increase of the axial kinetic energy is observed during the axial compression. (author)

  20. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  1. Temporal and Spatial Variability in the Geochemistry of Axial and CoAxial Segment Lavas and their Mantle Sources

    Science.gov (United States)

    Smith, M. C.; Perfit, M. R.; Davis, C.; Kamenov, G. D.

    2011-12-01

    Three spatially related volcanic eruptions along the CoAxial Segment of the Juan de Fuca Ridge (JdFR) have documented emplacements between 1981 and 1993. Two of the historic flows outcrop at the "Flow Site" and were emplaced within less than 12 years and 500 m from one another. The third was emplaced at the "Floc Site" to the south in the 1980s. Previous studies have documented that CoAxial lavas are among the most incompatible element and isotopically depleted lavas along the entire JdFR, whereas the Axial Seamount segment immediately south of CoAxial has erupted the most chemically enriched lavas south of the Endeavor Segment. Geochemical studies have shown little temporal change in the chemistry of recent Axial Seamount eruptives, whereas CoAxial lavas exhibit distinct chemical differences over short time periods. Significant chemical differences observed among depleted CoAxial lavas emplaced close to one another in space and time are in marked contrast to the relatively constant chemical characteristics of enriched lavas erupted at the magmatically more robust Axial segment only 10's of kilometers to the south and west. New trace element and isotopic (Sr, Nd, Pb) geochemical analyses of historic and older CoAxial lavas have resulted in better documentation of interflow and intraflow chemical variation providing an improved understanding of spatial/temporal chemical variability in lavas, and further insight into JdFR magmatic processes. Modeling of major and trace element abundances suggest that the observed intraflow chemical variation within CoAxial lavas is largely due to shallow-level fractional crystallization but that a single fractional crystallization model cannot account for all interflow chemical variation. In fact, elemental and isotopic data require different parental magmas for each of the three recent CoAxial Segment lava flows suggesting very short-term differences or changes in the chemical character of the mantle source region. In particular

  2. The impact of degenerative spinal changes on the correlation of peripheral and axial bone density

    International Nuclear Information System (INIS)

    Schneider, P.; Boerner, W.

    1994-01-01

    Results of bone density measurements by quantitative computed tomography of the peripheral skeleton (pQCT) were compared with those of measurements at the axial skeleton with a view to study the effects of degenerative spinal changes on the validity of bone densitometry of the lumbar spine. 556 consecutive patients were examined by dual-energy X-ray absorptiometry (DXA) of the spine and by peripheral quantitative computed tomography (pQCT) of the distal radius. There were significant differences between the bone mineral values at the distal radius and those at the spine, depending on the degree of spinal degeneration. As expected, spinal degenerations showed a highly significant age dependence. With increasing degeneration the correlations between the radius total bone mineral concentration and the bone density of the lumbar spine decreased from r=0.45 to 0.23 in women and from r=0.64 to 0.28 in men. We conclude that the value of spinal DXA is reduced in patients with degenerative spinal disease, compared to the pQCT at the peripheral skeleton. (orig.) [de

  3. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    International Nuclear Information System (INIS)

    Meng, Yiqing; Lucas, Gary P

    2017-01-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas–water and oil–gas–water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the

  4. Imaging water velocity and volume fraction distributions in water continuous multiphase flows using inductive flow tomography and electrical resistance tomography

    Science.gov (United States)

    Meng, Yiqing; Lucas, Gary P.

    2017-05-01

    This paper presents the design and implementation of an inductive flow tomography (IFT) system, employing a multi-electrode electromagnetic flow meter (EMFM) and novel reconstruction techniques, for measuring the local water velocity distribution in water continuous single and multiphase flows. A series of experiments were carried out in vertical-upward and upward-inclined single phase water flows and ‘water continuous’ gas-water and oil-gas-water flows in which the velocity profiles ranged from axisymmetric (single phase and vertical-upward multiphase flows) to highly asymmetric (upward-inclined multiphase flows). Using potential difference measurements obtained from the electrode array of the EMFM, local axial velocity distributions of the continuous water phase were reconstructed using two different IFT reconstruction algorithms denoted RT#1, which assumes that the overall water velocity profile comprises the sum of a series of polynomial velocity components, and RT#2, which is similar to RT#1 but which assumes that the zero’th order velocity component may be replaced by an axisymmetric ‘power law’ velocity distribution. During each experiment, measurement of the local water volume fraction distribution was also made using the well-established technique of electrical resistance tomography (ERT). By integrating the product of the local axial water velocity and the local water volume fraction in the cross section an estimate of the water volumetric flow rate was made which was compared with a reference measurement of the water volumetric flow rate. In vertical upward flows RT#2 was found to give rise to water velocity profiles which are consistent with the previous literature although the profiles obtained in the multiphase flows had relatively higher central velocity peaks than was observed for the single phase profiles. This observation was almost certainly a result of the transfer of axial momentum from the less dense dispersed phases to the water

  5. Ranking of computed tomography in diagnosis of avascular necrosis of femoral head in adults

    Energy Technology Data Exchange (ETDEWEB)

    Nebel, G

    1982-01-01

    On 12 patients (7 males, 5 females) with the diagnosis of avascular (aseptic) necrosis of the femoral head the value of computed tomography was investigated. Stages II-IV were observed (following the staging of Ficat and Arlet). Exept for 2 cases the findings of necrosis on axial CT-slices were always located in the anterior part of the femoral head. The problems of early diagnosis of the disease are discussed.

  6. Relation between axial length and ocular parameters

    Directory of Open Access Journals (Sweden)

    Xue-Qiu Yang

    2013-09-01

    Full Text Available AIM: To investigatethe relation between axial length(AL, age and ocular parameters.METHODS: A total of 360 subjects(360 eyeswith emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT, AL, intraocular pressure(IOPwere measured by automatic-refractor, Pachymeter, A-mode ultrasound and non-contact tonometer, respectively. Corneal curvature(CC, anterior chamber depth(ACDand white-to-white distance(WWDwere measured by Orbscan II. Three dimensional frequency domain coherent optical tomography(3D-OCTwas used to examine the retinal nerve fiber layer thickness(RNFLT. The Pearson correlation coefficient(rand multiple regression analysis were performed to evaluate the relationship between AL, age and ocular parameters.RESULTS: The average AL was 24.15±1.26mm. With elongation of the AL, spherical equivalent(SE(r=-0.742,Pr=-0.395, Pr=-0.374, Pr=0.411, Pr=0.099, P=0.060and WWD(r=0.061, P=0.252. There was also a significant correlation between AL and age(P=0.001, SE(PPPCONCLUSION: In longer eyes, there is a tendency toward myopia, a flatter cornea, a deeper ACD and a thinner RNFLT. Age is an influencing factor for the AL as well.

  7. Rare location of spondylitis tuberculosis;atlanto-axial, sacral and cervico-thoracic junction

    Science.gov (United States)

    Victorio; Nasution, M. D.; Ibrahim, S.; Dharmajaya, R.

    2018-03-01

    Three cases of rare location spondylitis tuberculosis are reported, each in atlantoaxial, cervico-thoracic junction,and sacral. The complaints were aweakness of motoric strength and local back pain. Patients’thoracal x-ray was normal, there was no complaint of acough, PCR forTB was early diagnostic and positive in all three cases, HIV negative, intraoperative tissue samplings were sent for histopathology examination and the results showed thespecific inflammatory process. Lesions were evaluated with computer tomography and/or MRI imaging.Preoperative TB regimens therapy were given for 2 weeks and continued for nine months. The surgical procedurewas done in all cases with excellent improvement of symptoms and motoric strength. In our institution,25 cases of total TB spondylitis were performed in 2 years, only 1 case eachwas found in atlanto-axial, cervico-thoracic and sacral.

  8. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  9. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  10. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  11. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    International Nuclear Information System (INIS)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    1981-01-01

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction

  12. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    Dimtrox, R.; Yonkova, P.; Vladova, D.; Kostov, D.

    2010-01-01

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  13. Bone Disease in Axial Spondyloarthritis.

    Science.gov (United States)

    Van Mechelen, Margot; Gulino, Giulia Rossana; de Vlam, Kurt; Lories, Rik

    2018-05-01

    Axial spondyloarthritis is a chronic inflammatory skeletal disorder with an important burden of disease, affecting the spine and sacroiliac joints and typically presenting in young adults. Ankylosing spondylitis, diagnosed by the presence of structural changes to the skeleton, is the prototype of this disease group. Bone disease in axial spondyloarthritis is a complex phenomenon with the coexistence of bone loss and new bone formation, both contributing to the morbidity of the disease, in addition to pain caused by inflammation. The skeletal structural changes respectively lead to increased fracture risk and to permanent disability caused by ankylosis of the sacroiliac joints and the spine. The mechanism of this new bone formation leading to ankylosis is insufficiently known. The process appears to originate from entheses, specialized structures that provide a transition zone in which tendon and ligaments insert into the underlying bone. Growth factor signaling pathways such as bone morphogenetic proteins, Wnts, and Hedgehogs have been identified as molecular drivers of new bone formation, but the relationship between inflammation and activation of these pathways remains debated. Long-standing control of inflammation appears necessary to avoid ankylosis. Recent evidence and concepts suggest an important role for biomechanical factors in both the onset and progression of the disease. With regard to new bone formation, these processes can be understood as ectopic repair responses secondary to inflammation-induced bone loss and instability. In this review, we discuss the clinical implications of the skeletal changes as well as the underlying molecular mechanisms, the relation between inflammation and new bone formation, and the potential role of biomechanical stress.

  14. Axial Permanent Magnet Generator for Wearable Energy Harvesting

    DEFF Research Database (Denmark)

    Högberg, Stig; Sødahl, Jakob Wagner; Mijatovic, Nenad

    2016-01-01

    An increasing demand for battery-free electronics is evident by the rapid increase of wearable devices, and the design of wearable energy harvesters follows accordingly. An axial permanent magnet generator was designed to harvest energy from human body motion and supplying it to a wearable......W, respectively) with an iron yoke is subject to losses that exceed the realistic input power, and was therefore deemed infeasible. A generator without the iron yoke was concluded to perform well as a wearable energy harvester. An experimental investigation of a prototype revealed an output power of almost 1 m...

  15. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  16. Three dimensional time reversal optical tomography

    Science.gov (United States)

    Wu, Binlin; Cai, W.; Alrubaiee, M.; Xu, M.; Gayen, S. K.

    2011-03-01

    Time reversal optical tomography (TROT) approach is used to detect and locate absorptive targets embedded in a highly scattering turbid medium to assess its potential in breast cancer detection. TROT experimental arrangement uses multi-source probing and multi-detector signal acquisition and Multiple-Signal-Classification (MUSIC) algorithm for target location retrieval. Light transport from multiple sources through the intervening medium with embedded targets to the detectors is represented by a response matrix constructed using experimental data. A TR matrix is formed by multiplying the response matrix by its transpose. The eigenvectors with leading non-zero eigenvalues of the TR matrix correspond to embedded objects. The approach was used to: (a) obtain the location and spatial resolution of an absorptive target as a function of its axial position between the source and detector planes; and (b) study variation in spatial resolution of two targets at the same axial position but different lateral positions. The target(s) were glass sphere(s) of diameter ~9 mm filled with ink (absorber) embedded in a 60 mm-thick slab of Intralipid-20% suspension in water with an absorption coefficient μa ~ 0.003 mm-1 and a transport mean free path lt ~ 1 mm at 790 nm, which emulate the average values of those parameters for human breast tissue. The spatial resolution and accuracy of target location depended on axial position, and target contrast relative to the background. Both the targets could be resolved and located even when they were only 4-mm apart. The TROT approach is fast, accurate, and has the potential to be useful in breast cancer detection and localization.

  17. Utility of computed axial tomography angiography in anatomic evaluation of pediatric patients with congenital heart diseases

    International Nuclear Information System (INIS)

    Mosquera, Walter A; Reyes P, Rafael; Aguilera N, Favio M; Breton, Cesar A; Buitrago, Danuby A; Suarez J Ramiro; Castillo, Victor

    2007-01-01

    Although echocardiogram and cardiac catheterization are used as first option tools for congenital heart diseases diagnosis, computed tomography angiography is a minimally invasive exam that through two to three dimensional images in real time gives an adequate approach to patients having this type of pathologies that require a rapid and precise evaluation of its extra cardiac anatomy. Objective: describe the institutional experience from August 2005 to August 2006 in the use of angiography by tomography as a complementary diagnostic method in the evaluation of pediatric patients with congenital heart diseases. Method: serial descriptive study. 58 pediatric patients with clinical and echocardiographic diagnosis of congenital heart diseases were evaluated through the General Electric Multislice Light peed/16 scanner. Results: 58 patients with history of congenital heart disease were evaluated through CT angiography. Mean age was 2.4 ± 4.03 years. Twenty (33.8%) had diagnosis of pulmonary atresia, four (6.7%) had tricuspid atresia, eight (13.5%,) had double-outlet right ventricle, seven (11.8%) had tetralogy of Fallot, nine (15.2%) had alterations of the aortic arch, seven (11.8%) had coarctation of the aorta two (3.3%) had interrupted aortic arch, six (10.3%) had persistent ductus arteriosus, four (6.7%) had anomalous venous drainage and three (5.1 %) had transposition of the great arteries. High quality images that allowed assessing the precise vascular anatomy were obtained. Conclusions: computed tomography angiography turned out to be a useful tool in the diagnostic approach of congenital heart diseases, because it allowed a tridimensional anatomic reconstruction. New studies that may permit the assessment of sensitivity, specificity and concordance level of this technique with other invasive diagnostic methods available for the diagnosis of this type of diseases, are required

  18. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Science.gov (United States)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  19. Inverse axial mounting stiffness design for lithographic projection lenses.

    Science.gov (United States)

    Wen-quan, Yuan; Hong-bo, Shang; Wei, Zhang

    2014-09-01

    In order to balance axial mounting stiffness of lithographic projection lenses and the image quality under dynamic working conditions, an easy inverse axial mounting stiffness design method is developed in this article. Imaging quality deterioration at the wafer under different axial vibration levels is analyzed. The desired image quality can be determined according to practical requirements, and axial vibrational tolerance of each lens is solved with the damped least-squares method. Based on adaptive interval adjustment, a binary search algorithm, and the finite element method, the axial mounting stiffness of each lens can be traveled in a large interval, and converges to a moderate numerical solution which makes the axial vibrational amplitude of the lens converge to its axial vibrational tolerance. Model simulation is carried out to validate the effectiveness of the method.

  20. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  1. Ranking of computed tomography in diagnosis of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Nebel, G.

    1982-01-01

    On 12 patients (7 males, 5 females) with the diagnosis of avascular (aseptic) necrosis of the femoral head the value of computed tomography was investigated. Stages II-IV were observed (following the staging of Ficat and Arlet). Exept for 2 cases the findings of necrosis on axial CT-slices were always located in the anterior part of the femoral head. The problems of early diagnosis of the disease are discussed. (orig.) [de

  2. Quantitative analysis of cone photoreceptor distribution and its relationship with axial length, age, and early age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Ryo Obata

    Full Text Available PURPOSE: It has not been clarified whether early age-related macular degeneration (AMD is associated with cone photoreceptor distribution. We used adaptive optics fundus camera to examine cone photoreceptors in the macular area of aged patients and quantitatively analyzed its relationship between the presence of early AMD and cone distribution. METHODS: Sixty cases aged 50 or older were studied. The eyes were examined with funduscopy and spectral-domain optical coherence tomography to exclude the eyes with any abnormalities at two sites of measurement, 2° superior and 5° temporal to the fovea. High-resolution retinal images with cone photoreceptor mosaic were obtained with adaptive optics fundus camera (rtx1, Imagine Eyes, France. After adjusting for axial length, cone packing density was calculated and the relationship with age, axial length, or severity of early AMD based on the age-related eye disease study (AREDS classification was analyzed. RESULTS: Patient's age ranged from 50 to 77, and axial length from 21.7 to 27.5 mm. Mean density in metric units and that in angular units were 24,900 cells/mm2, 2,170 cells/deg2 at 2° superior, and 18,500 cells/mm2, 1,570 cels/deg2 at 5° temporal, respectively. Axial length was significantly correlated with the density calculated in metric units, but not with that in angular units. Age was significantly correlated with the density both in metric and angular units at 2° superior. There was no significant difference in the density in metric and angular units between the eyes with AREDS category one and those with categories two or three. CONCLUSION: Axial length and age were significantly correlated with parafoveal cone photoreceptor distribution. The results do not support that early AMD might influence cone photoreceptor density in the area without drusen or pigment abnormalities.

  3. Spectral domain optical coherence tomography imaging of spectacular ecdysis in the royal python (Python regius).

    Science.gov (United States)

    Tusler, Charlotte A; Maggs, David J; Kass, Philip H; Paul-Murphy, Joanne R; Schwab, Ivan R; Murphy, Christopher J

    2015-01-01

    To describe using spectral domain optical coherence tomography (SD-OCT), digital slit-lamp biomicroscopy, and external photography, changes in the ophidian cuticle, spectacle, and cornea during ecdysis. Four normal royal pythons (Python regius). Snakes were assessed once daily throughout a complete shed cycle using nasal, axial, and temporal SD-OCT images, digital slit-lamp biomicroscopy, and external photography. Spectral domain optical coherence tomography (SD-OCT) images reliably showed the spectacular cuticle and stroma, subcuticular space (SCS), cornea, anterior chamber, iris, and Schlemm's canal. When visible, the subspectacular space (SSS) was more distended peripherally than axially. Ocular surface changes throughout ecdysis were relatively conserved among snakes at all three regions imaged. From baseline (7 days following completion of a full cycle), the spectacle gradually thickened before separating into superficial cuticular and deep, hyper-reflective stromal components, thereby creating the SCS. During spectacular separation, the stroma regained original reflectivity, and multiple hyper-reflective foci (likely fragments from the cuticular-stromal interface) were noted within the SCS. The cornea was relatively unchanged in character or thickness throughout all stages of ecdysis. Slit-lamp images did not permit observation of these changes. Spectral domain optical coherence tomography (SD-OCT) provided excellent high-resolution images of the snake anterior segment, and especially the cuticle, spectacle, and cornea of manually restrained normal snakes at all stages of ecdysis and warrants investigation in snakes with anterior segment disease. The peripheral spectacle may be the preferred entry point for diagnostic or therapeutic injections into the SSS and for initiating spectacular surgery. © 2014 American College of Veterinary Ophthalmologists.

  4. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  5. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    Science.gov (United States)

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  6. Label-free evanescent microscopy for membrane nano-tomography in living cells.

    Science.gov (United States)

    Bon, Pierre; Barroca, Thomas; Lévèque-Fort, Sandrine; Fort, Emmanuel

    2014-11-01

    We show that through-the-objective evanescent microscopy (epi-EM) is a powerful technique to image membranes in living cells. Readily implementable on a standard inverted microscope, this technique enables full-field and real-time tracking of membrane processes without labeling and thus signal fading. In addition, we demonstrate that the membrane/interface distance can be retrieved with 10 nm precision using a multilayer Fresnel model. We apply this nano-axial tomography of living cell membranes to retrieve quantitative information on membrane invagination dynamics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  7. Estimation of Chromatographic Columns Performances using Computer Tomography and CFD Simulations

    DEFF Research Database (Denmark)

    Schmidt, Irma; Lottes, Florian; Minceva, Mirjana

    2011-01-01

    The flow inside a chromatographic column depends decisively on the packed bed inside. Non‐destructive X‐ray computed tomography (CT) was applied as a novel measurement technique to visualize the distribution of velocity and axial dispersion coefficients in preparative scale columns. The results...... show, that spherical particles seem to be more efficient than irregular ones in terms of HETP, which has to be partly a result of the more homogeneous flow profile they induce. The prediction of column performance in dependence of the structure of the packed bed was simulated by CFD (Computational...

  8. Metastatic disease of the brain: extra-axial metastases (skull, dura, leptomeningeal) and tumour spread

    Energy Technology Data Exchange (ETDEWEB)

    Maroldi, Roberto; Ambrosi, Claudia; Farina, Davide [University of Brescia, Department of Radiology, Brescia, BS (Italy)

    2005-03-01

    Extra-axial intracranial metastases may arise through several situations. Hematogenous spread to the meninges is the most frequent cause. Direct extension from contiguous extra-cranial neoplasms, secondary invasion of the meninges by calvarium and skull base metastases, and migration along perineural or perivascular structures are less common. Leptomeningeal invasion gives rise to tumour cell dissemination by the cerebrospinal fluid (CSF), eventually leading to neoplastic coating of brain surfaces. Contrast-enhanced magnetic resonance (MR) imaging is complementary to CSF examinations and can be invaluable, detecting up to 50% of false-negative lumbar punctures. MR findings range from diffuse linear leptomeningeal enhancement to multiple enhancing extra-axial nodules, obstructive communicating and non-communicating hydrocephalus. Both calvarial and epidural metastases infrequently transgress the dura, which acts as a barrier against tumour spread. Radionuclide bone studies are still a valuable screening test to detect bone metastases. With computed tomography (CT) and MR, bone metastases extending intracranially and primary dural metastases show the characteristic biconvex shape, usually associated with brain displacement away from the inner table. Although CT is better in detecting skull base erosion, MR is more sensitive and provides more detailed information about dural involvement. Perineural and perivascular spread from head and neck neoplasms require thin-section contrast-enhanced MR. (orig.)

  9. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  10. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  11. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...... position displays complex behavior with regions of positive and negative interference. By analyzing the scattered light intensity as a function of the axial position of the trapped sphere, we propose a simple method to increase the sensitivity and control the linear range of axial position detection....

  12. Magnetic resonance tomography and computed tomography of the brain for diagnosing Wilson's disease

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Straube, A.; Beyer, H.K.; Leopold, H.C.

    1985-01-01

    The authors report on two woman patients with confirmed Wilson's desease (hepatolenticular degeneration) who had neurological deficits and showed typical changes evident from laboratory data. Both computed tomography and magnetic resonance tomography revealed degenerative changes in the basal ganglia, especially of the lenticular nucleus, MR showing these defects more clearly than CT. There was a noticeable symmetrical enhancement of signals in the lenticular nucleus which was particularly evident on the image basing on the T 2 (spin-spin relaxation time constant) values. MR could be superior to CT with regard to showing up pathological changes in the basal ganglia. The future indication of MR could be the establishment of an exact correlation between clinical signs and symptoms on the one hand, and morphological findings on the other. Over and above this, it should be explored to what extent MR can already detect degenerative changes in the brain in primarily hepatic types of the disease even without prior neurological examination. (orig.) [de

  13. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  14. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology.

    Science.gov (United States)

    Tsai, Tsung-Han; Lee, Hsiang-Chieh; Ahsen, Osman O; Liang, Kaicheng; Giacomelli, Michael G; Potsaid, Benjamin M; Tao, Yuankai K; Jayaraman, Vijaysekhar; Figueiredo, Marisa; Huang, Qin; Cable, Alex E; Fujimoto, James; Mashimo, Hiroshi

    2014-12-01

    We describe an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor imaging catheter. The system had a 600 kHz axial scan rate and 8 µm axial resolution in tissue. Imaging was performed with a 3.2 mm diameter imaging catheter at 400 frames per second with a 12 µm spot size. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing upper and lower endoscopy. The use of distally actuated imaging catheters enabled OCT imaging with more flexibility, such as volumetric imaging in the small intestine and the assessment of hiatal hernia using retroflex imaging. The high rotational scanning stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face OCT and cross-sectional imaging, as well as OCT angiography (OCTA) for 3D visualization of subsurface microvasculature. The ability to perform both structural and functional 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies and enhance the sensitivity and specificity of OCT for detecting pathology.

  15. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Ocean acoustic tomography

    International Nuclear Information System (INIS)

    Cornuelle, Bruce D; Worcester, Peter F; Dzieciuch, Matthew A

    2008-01-01

    Ocean acoustic tomography (OAT) was proposed in 1979 by Walter Munk and Carl Wunsch as an analogue to x-ray computed axial tomography for the oceans. The oceans are opaque to most electromagnetic radiation, but there is a strong acoustic waveguide, and sound can propagate for 10 Mm and more with distinct multiply-refracted ray paths. Transmitting broadband pulses in the ocean leads to a set of impulsive arrivals at the receiver which characterize the impulse response of the sound channel. The peaks observed at the receiver are assumed to represent the arrival of energy traveling along geometric ray paths. These paths can be distinguished by arrival time, and by arrival angle when a vertical array of receivers is available. Changes in ray arrival time can be used to infer changes in ocean structure. Ray travel time measurements have been a mainstay of long-range acoustic measurements, but the strong sensitivity of ray paths to range-dependent sound speed perturbations makes the ray sampling functions uncertain in real cases. In the ray approximation travel times are sensitive to medium changes only along the corresponding eigenrays. Ray theory is an infinite-frequency approximation, and its eikonal equation has nonlinearities not found in the acoustic wave equation. We build on recent seismology results (kernels for body wave arrivals in the earth) to characterize the kernel for converting sound speed change in the ocean to travel time changes using more complete propagation physics. Wave-theoretic finite frequency kernels may show less sensitivity to small-scale sound speed structure.

  17. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  18. Value of conventional tomography and computerized tomography in therapy resistant affections of the nasal sinuses

    International Nuclear Information System (INIS)

    Rieden, K.; Frey, M.; Mayer, B.

    1986-01-01

    The informational value of conventional tomography as primary diagnostic method is pointed out in diseases of nasal sinuses resistant to therapy. 5 cases demonstrate the additional information gained by CT-differentiation of soft tissue structures, intraorbital and intracranial expansion. In 78.4% of the examined group of 51 patients conventional tomography allowed the diagnosis of a process limited to the nasal sinuses, further evidence by CT could be omitted. In 11 patients examined by CT additionally, the expansion of the process was defined more precisely and the assumed intraorbital and intracranial growth confirmed. (orig.) [de

  19. Axial anomaly at finite temperature and finite density

    International Nuclear Information System (INIS)

    Qian Zhixin; Su Rukeng; Yu, P.K.N.

    1994-01-01

    The U(1) axial anomaly in a hot fermion medium is investigated by using the real time Green's function method. After calculating the lowest order triangle diagrams, we find that finite temperature as well as finite fermion density does not affect the axial anomaly. The higher order corrections for the axial anomaly are discussed. (orig.)

  20. Optical Coherence Tomography for the Assessment of Coronary Atherosclerosis and Vessel Response after Stent Implantation

    OpenAIRE

    Gonzalo, Nieves

    2010-01-01

    textabstractOptical Coherence Tomography (OCT) is a light-based imaging modality that can provide in vivo high-resolution images of the coronary artery with a level of resolution (axial 10-20 µm) ten times higher than intravascular ultrasound. The technique, uses low-coherent near infrarred light to create high-resolution cross sectional images of the vessel. The technology refinement achieved in the last years has made this imaging modality less procedurally demanding opening its possibiliti...

  1. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  2. Transverse tomography and radiotherapy

    International Nuclear Information System (INIS)

    Leer, J.W.H.

    1982-01-01

    This study was intended to delineate the indications for radiotherapy treatment-planning with the help of computerized axial tomography (C.T.) and transverse analog tomography (T.A.T.). Radiotherapy localisation procedures with the conventional method (simulator), with the CT-scanner and with the transverse analog tomograph (T.A.T., Simtomix, Oldelft) were compared. As criterium for evaluation differences in reconstruction drawing based on these methods were used. A certain method was judged ''superior'' to another if the delineation of the target volume was more accurate, if a better impression was gained of the site of (for irradiation) organs at risk, or if the localisation could only be performed with that method. The selected group of patients consisted of 120 patients for whom a reconstruction drawing in the transverse plane was made according to the treatment philosophy. In this group CT-assisted localisation was judged on 68 occasions superior to the conventional method. In a number of cases it was found that a ''standard'' change in a standard target volume, on the base of augmented anatomical knowledge, made the conventional method sufficient. The use of CT-scanner for treatment planning was estimated. For ca. 270/1000 new patients a CT-scan is helpful (diagnostic scan), for 140 of them the scan is necessary (planning scan). The quality of the anatomical information obtained with the T.A.T. does not yet fall within acceptable limits, but progress has been made. (Auth.)

  3. Safety of intravenous tissue plasminogen activator administration with computed tomography evidence of prior infarction.

    Science.gov (United States)

    Lyerly, Michael J; Houston, J Thomas; Boehme, Amelia K; Albright, Karen C; Bavarsad Shahripour, Reza; Palazzo, Paola; Alvi, Muhammed; Rawal, Pawan V; Kapoor, Niren; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2014-07-01

    Prior stroke within 3 months excludes patients from thrombolysis; however, patients may have computed tomography (CT) evidence of prior infarct, often of unknown time of origin. We aimed to determine if the presence of a previous infarct on pretreatment CT is a predictor of hemorrhagic complications and functional outcomes after the administration of intravenous (IV) tissue plasminogen activator (tPA). We retrospectively analyzed consecutive patients treated with IV tPA at our institution from 2009-2011. Pretreatment CTs were reviewed for evidence of any prior infarct. Further review determined if any hemorrhagic transformation (HT) or symptomatic intracerebral hemorrhage (sICH) were present on repeat CT or magnetic resonance imaging. Outcomes included sICH, any HT, poor functional outcome (modified Rankin Scale score of 4-6), and discharge disposition. Of 212 IV tPA-treated patients, 84 (40%) had evidence of prior infarct on pretreatment CT. Patients with prior infarcts on CT were older (median age, 72 versus 65 years; P=.001) and had higher pretreatment National Institutes of Health Stroke Scale scores (median, 10 versus 7; P=.023). Patients with prior infarcts on CT did not experience more sICH (4% versus 2%; P=.221) or any HT (18% versus 14%; P=.471). These patients did have a higher frequency of poor functional outcome at discharge (82% versus 50%; P<.001) and were less often discharged to home or inpatient rehabilitation center (61% versus 73%; P=.065). Visualization of prior infarcts on pretreatment CT did not predict an increased risk of sICH in our study and should not be viewed as a reason to withhold systemic tPA treatment after clinically evident strokes within 3 months were excluded. Published by Elsevier Inc.

  4. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    International Nuclear Information System (INIS)

    Wagner, J.C.; DeHart, M.D.

    2000-01-01

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ''end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified

  5. Research on a novel axial-flux magnetic-field-modulated brushless double-rotor machine with low axial force and high efficiency

    Directory of Open Access Journals (Sweden)

    Chengde Tong

    2017-05-01

    Full Text Available The axial-flux magnetic-field-modulated brushless double-rotor machine (MFM-BDRM is a possible alternative as a power-split device for hybrid electric vehicles (HEVs. However, the existence of large axial force may lead to assembly problems and rich inner air-gap harmonics could result in high PM loss and low efficiency. This paper proposes a novel axial-flux MFM-BDRM with improved PM rotor structure. 2-D analytical method to predict the magnetic-field distribution of the proposed MFM-BDRM is developed and the design procedure of the proposed machine is illustrated. The impact of key geometrical parameters on axial force and torque is investigated. To evaluate the advantage of the proposed machine, a comparison is made with a conventional one with respect to electromagnetic performances. Results show that the proposed machine is effective in reducing PM eddy loss and axial force by 60% and 35%, respectively.

  6. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  7. Improving the lattice axial vector current

    International Nuclear Information System (INIS)

    Horsley, R.; Perlt, H.; Schiller, A.; Zanotti, J.M.

    2015-11-01

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order O(a) effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  8. Are Hox genes ancestrally involved in axial patterning? Evidence from the hydrozoan Clytia hemisphaerica (Cnidaria.

    Directory of Open Access Journals (Sweden)

    Roxane Chiori

    Full Text Available BACKGROUND: The early evolution and diversification of Hox-related genes in eumetazoans has been the subject of conflicting hypotheses concerning the evolutionary conservation of their role in axial patterning and the pre-bilaterian origin of the Hox and ParaHox clusters. The diversification of Hox/ParaHox genes clearly predates the origin of bilaterians. However, the existence of a "Hox code" predating the cnidarian-bilaterian ancestor and supporting the deep homology of axes is more controversial. This assumption was mainly based on the interpretation of Hox expression data from the sea anemone, but growing evidence from other cnidarian taxa puts into question this hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: Hox, ParaHox and Hox-related genes have been investigated here by phylogenetic analysis and in situ hybridisation in Clytia hemisphaerica, an hydrozoan species with medusa and polyp stages alternating in the life cycle. Our phylogenetic analyses do not support an origin of ParaHox and Hox genes by duplication of an ancestral ProtoHox cluster, and reveal a diversification of the cnidarian HOX9-14 genes into three groups called A, B, C. Among the 7 examined genes, only those belonging to the HOX9-14 and the CDX groups exhibit a restricted expression along the oral-aboral axis during development and in the planula larva, while the others are expressed in very specialised areas at the medusa stage. CONCLUSIONS/SIGNIFICANCE: Cross species comparison reveals a strong variability of gene expression along the oral-aboral axis and during the life cycle among cnidarian lineages. The most parsimonious interpretation is that the Hox code, collinearity and conservative role along the antero-posterior axis are bilaterian innovations.

  9. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  10. Δ(1232) Axial Charge and Form Factors from Lattice QCD

    International Nuclear Information System (INIS)

    Alexandrou, Constantia; Gregory, Eric B.; Korzec, Tomasz; Koutsou, Giannis; Negele, John W.; Sato, Toru; Tsapalis, Antonios

    2011-01-01

    We present the first calculation on the Δ axial vector and pseudoscalar form factors using lattice QCD. Two Goldberger-Treiman relations are derived and examined. A combined chiral fit is performed to the nucleon axial charge, N to Δ axial transition coupling constant and Δ axial charge.

  11. Optical computed tomography for imaging the breast: first look

    Science.gov (United States)

    Grable, Richard J.; Ponder, Steven L.; Gkanatsios, Nikolaos A.; Dieckmann, William; Olivier, Patrick F.; Wake, Robert H.; Zeng, Yueping

    2000-07-01

    The purpose of the study is to compare computed tomography optical imaging with traditional breast imaging techniques. Images produced by computed tomography laser mammography (CTLMTM) scanner are compared with images obtained from mammography, and in some cases ultrasound and/or magnetic resonance imaging (MRI). During the CTLM procedure, a near infrared laser irradiates the breast and an array of photodiodes detectors records light scattered through the breast tissue. The laser and detectors rotate synchronously around the breast to acquire a series of slice data along the coronal place. The procedure is performed without any breast compression or optical matching fluid. Cross-sectional slices of the breast are produced using a reconstruction algorithm. Reconstruction based on the diffusion theory is used to produce cross-sectional slices of the breast. Multiple slice images are combined to produce a three dimensional volumetric array of the imaged breast. This array is used to derive axial and sagittal images of the breast corresponding to cranio-caudal and medio-lateral images used in mammography. Over 200 women and 3 men have been scanned in clinical trials. The most obvious features seen in images produced by the optical tomography scanner are vascularization and significant lesions. Breast features caused by fibrocystic changes and cysts are less obvious. Breast density does not appear to be a significant factor in the quality of the image. We see correlation of the optical image structure with that seen with traditional breast imaging techniques. Further testing is being conducted to explore the sensitivity and specificity of optical tomography of the breast.

  12. Computerized tomography of the vertebral column following traumatic lesion

    International Nuclear Information System (INIS)

    Taenzer, B.; Gmelin, E.; Burmester, E.; Babaian, E.; Weiss, H.D.; Hohlbach, G.

    1984-01-01

    In 58 patients with lesions of the vertebral column in the thoracal and lumbar section established by conventional X-ray, the informative power of computerized tomography was tested. Axial projection with the superimposition-free presentation of bone and soft-tissue structures in the motional segment clears up the diagnostically decisive question of the extent of the lesion and form of fracture, and thus provides information on the stability or instability of the fracture relevant for the therapeutic action taken. All patients had compression fractures of vertebrae, with a fragment of the front edge broken away in 50 cases and one of the back edge broken away in 17 cases. In 30 cases the intervertebral disks were damaged. 43 fractures were stable, 25 were unstable. The instability of 13 fractures was only recognized by CT. In essence, the diagnostic action to be taken begins with a grand-survey X-ray in two planes as a screening, with computerized tomography following in the positive case. Conventional tomograms are not necessary. (BWU) [de

  13. Recurrent anterior shoulder instability: accuracy of estimations of glenoid bone loss with computed tomography is insufficient for therapeutic decision-making

    Energy Technology Data Exchange (ETDEWEB)

    Huijsmans, Polydoor Emile [Haga Hospital, Department of Orthopedic Surgery, The Hague (Netherlands); Witte, Pieter Bas de [Leiden University Medical Center, Department of Orthopedic Surgery, Leiden (Netherlands); Villiers, Richard V.P. de; Kruger, Niel Ruben [Van Wageningen and Partners, Radiology Department, Somerset West (South Africa); Wolterbeek, Derk Willem; Warmerdam, Piet [Haga Hospital, Department of Radiology, The Hague (Netherlands); Beer, Joe F. de [Cape Shoulder Institute, Department of Orthopedic Surgery, Cape Town (South Africa)

    2011-10-15

    To evaluate the reliability of glenoid bone loss estimations based on either axial computed tomography (CT) series or single sagittal (''en face'' to glenoid) CT reconstructions, and to assess their accuracy by comparing with actual CT-based bone loss measurements, in patients with anterior glenohumeral instability. In two separate series of patients diagnosed with recurrent anterior glenohumeral instability, glenoid bone loss was estimated on axial CT series and on the most lateral sagittal (en face) glenoid view by two blinded radiologists. Additionally, in the second series of patients, glenoid defects were measured on sagittal CT reconstructions by an independent observer. In both series, larger defects were estimated when based on sagittal CT images compared to axial views. In the second series, mean measured bone loss was 11.5% (SD = 6.0) of the total original glenoid area, with estimations of 9.6% (SD = 7.2) and 7.8% (SD = 4.2) for sagittal and axial views, respectively. Correlations of defect estimations with actual measurements were fair to poor; glenoid defects tended to be underestimated, especially when based on axial views. CT-based estimations of glenoid bone defects are inaccurate. Especially for axial views, there is a high chance of glenoid defect underestimation. When using glenoid bone loss quantification in therapeutic decision-making, measuring the defect instead of estimating is strongly advised. (orig.)

  14. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    NARCIS (Netherlands)

    B. Antony (Bhavna); M.D. Abràmoff (Michael); L. Tang (Li); W.D. Ramdas (Wishal); J.R. Vingerling (Hans); N.M. Jansonius (Nomdo); K. Lee (Kyungmoo); Y.H. Kwon (Young); M. Sonka (Milan); M.K. Garvin (Mona)

    2011-01-01

    textabstractThe 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate

  15. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  16. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  17. Two-dimensional nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed

    International Nuclear Information System (INIS)

    Ghayesh, Mergen H.; Amabili, Marco; Farokhi, Hamed

    2013-01-01

    In the present study, the coupled nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed is investigated employing a numerical technique. The equations of motion for both the transverse and longitudinal motions are obtained using Newton’s second law of motion and the constitutive relations. A two-parameter rheological model of the Kelvin–Voigt energy dissipation mechanism is employed in the modelling of the viscoelastic beam material, in which the material time derivative is used in the viscoelastic constitutive relation. The Galerkin method is then applied to the coupled nonlinear equations, which are in the form of partial differential equations, resulting in a set of nonlinear ordinary differential equations (ODEs) with time-dependent coefficients due to the axial acceleration. A change of variables is then introduced to this set of ODEs to transform them into a set of first-order ordinary differential equations. A variable step-size modified Rosenbrock method is used to conduct direct time integration upon this new set of first-order nonlinear ODEs. The mean axial speed and the amplitude of the speed variations, which are taken as bifurcation parameters, are varied, resulting in the bifurcation diagrams of Poincaré maps of the system. The dynamical characteristics of the system are examined more precisely via plotting time histories, phase-plane portraits, Poincaré sections, and fast Fourier transforms (FFTs)

  18. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    NARCIS (Netherlands)

    Antony, Bhavna; Abramoff, Michael D.; Tang, Li; Ramdas, Wishal D.; Vingerling, Johannes R.; Jansonius, Nomdo M.; Lee, Kyungmoo; Kwon, Young H.; Sonka, Milan; Garvin, Mona K.

    2011-01-01

    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct

  19. AXIALLY ORIENTED SECTIONS OF NUMMULITIDS: A TOOL TO INTERPRET LARGER BENTHIC FORAMINIFERAL DEPOSITS.

    Science.gov (United States)

    Hohenegger, Johann; Briguglio, Antonino

    2012-04-01

    The "critical shear velocity" and "settling velocity" of foraminiferal shells are important parameters for determining hydrodynamic conditions during deposition of Nummulites banks. These can be estimated by determining the size, shape, and density of nummulitid shells examined in axial sections cut perpendicular to the bedding plane. Shell size and shape can be determined directly from the shell diameter and thickness, but density must be calculated indirectly from the thin section. Calculations using the half-tori method approximate shell densities by equalizing the chamber volume of each half whorl, based on the half whorl's lumen area and its center of gravity. Results from this method yield the same lumen volumes produced empirically by micro-computed tomography. The derived hydrodynamic parameters help estimate the minimum flow velocities needed to entrain nummulitid tests and provide a potential tool to account for the nature of their accumulations.

  20. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido

    2007-01-01

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  1. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido [Hospital Heliopolis, Sao Paulo, SP (Brazil). Dept. de Cirurgia de Cabeca e Pescoco, Otorrinolaringologia e Imagem]. E-mail: ricapires@ig.com.br; olger1@uol.com.br

    2007-03-15

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  2. Stochastic quantization for the axial model

    International Nuclear Information System (INIS)

    Farina, C.; Montani, H.; Albuquerque, L.C.

    1991-01-01

    We use bosonization ideas to solve the axial model in the stochastic quantization framework. We obtain the fermion propagator of the theory decoupling directly the Langevin equation, instead of the Fokker-Planck equation. In the Appendix we calculate explicitly the anomalous divergence of the axial-vector current by using a regularization that does not break the Markovian character of the stochastic process

  3. Nonperturbative Aspects of Axial Vector Vertex

    Institute of Scientific and Technical Information of China (English)

    ZONG Hong-Shi; CHEN Xiang-Song; WANG Fan; CHANG Chao-Hsi; ZHAO En-Guang

    2002-01-01

    It is shown how the axial vector current of current quarks is related to that of constituent quarks within the framework of the global color symmetry model.Gluon dressing of the axial vector vertex and the quark self-energy functions are described by the inhomogeneous Bethe-Salpeter equation in the ladder approximation and the Schwinger Dyson equation in the rainbow approximation,respectively.

  4. Ultra-High Resolution Optical Coherence Tomography Imaging of Unilateral Drusen in a 31 Year Old Woman.

    Science.gov (United States)

    de Carlo, Talisa E; Adhi, Mehreen; Lu, Chen D; Duker, Jay S; Fujimoto, James G; Waheed, Nadia K

    We report a case of widespread unilateral drusen in a healthy 31 year old Caucasian woman using multi-modal imaging including ultra-high resolution optical coherence tomography (UHR-OCT). Dilated fundus exam showed multiple drusen-like lesions in the posterior pole without heme or fluid. Fundus auto fluorescence demonstrated hyperautofluorescent at the deposits. Fluorescein angiography revealed mild hyperfluorescence and staining of the lesions. Spectral-domain optical coherence tomography (SD-OCT) OS showed accumulations in the temporal macula at Bruch's membrane. UHR-OCT provided improved axial resolution compared to the standard 5 μm on the commercial SD-OCT and confirmed the presence of deposits in Bruch's membrane, consistent with drusen. The retinal layers were draped over the excrescences but did not show any disruption.

  5. Conservative axial burnup distributions for actinide-only burnup credit

    International Nuclear Information System (INIS)

    Kang, C.; Lancaster, D.

    1997-11-01

    Unlike the fresh fuel approach, which assumes the initial isotopic compositions for criticality analyses, any burnup credit methodology must address the proper treatment of axial burnup distributions. A straightforward way of treating a given axial burnup distribution is to segment the fuel assembly into multiple meshes and to model each burnup mesh with the corresponding isotopic compositions. Although this approach represents a significant increase in modeling efforts compared to the uniform average burnup approach, it can adequately determine the reactivity effect of the axial burnup distribution. A major consideration is what axial burnup distributions are appropriate for use in light of many possible distributions depending on core operating conditions and histories. This paper summarizes criticality analyses performed to determine conservative axial burnup distributions. The conservative axial burnup distributions presented in this paper are included in the Topical Report on Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel Packages, Revision 1 submitted in May 1997 by the US Department of Energy (DOE) to the US Nuclear Regulatory Commission (NRC). When approved by NRC, the conservative axial burnup distributions may be used to model PWR spent nuclear fuel for the purpose of gaining actinide only burnup credit

  6. Squamous cell carcinoma of the external auditory canal: computed tomography findings in six cases

    International Nuclear Information System (INIS)

    Gonzalez, Fabio Mota; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Souza, Ricardo Pires de

    2005-01-01

    Objective: to evaluate the role of computed tomography in the assessment of deep extension of squamous cell carcinoma of the external auditory canal. Materials and methods: in the period between May 1995 and December 2003 six patients with squamous cell carcinoma of the external auditory canal were submitted to computed tomography scan at 'Hospital Heliopolis', Sao Paulo, SP, Brazil, including axial and coronal slices with soft tissue and bone algorithms. Results: thickening of the soft tissue of the external auditory canal was seen in all patients, bone erosion and invasion of the middle ear in five (83.3%), invasion of the mastoid and parotid gland in four (66.7%), invasion of the temporomandibular joint in three (50%), and invasion of the middle cranial fossa, carotid canal and cervical lymph node enlargement in two (33.3%) patients. Conclusion: assessment of deep extension of squamous cell carcinoma of the external auditory canal using computed tomography is useful for clinical staging of the disease allowing better therapeutic planning for these patients. (author)

  7. Cladding axial elongation models for FRAP-T6

    International Nuclear Information System (INIS)

    Shah, V.N.; Carlson, E.R.; Berna, G.A.

    1983-01-01

    This paper presents a description of the cladding axial elongation models developed at the Idaho National Engineering Laboratory (INEL) for use by the FRAP-T6 computer code in analyzing the response of fuel rods during reactor transients in light water reactors (LWR). The FRAP-T6 code contains models (FRACAS-II subcode) that analyze the structural response of a fuel rod including pellet-cladding-mechanical-interaction (PCMI). Recently, four models were incorporated into FRACAS-II to calculate cladding axial deformation: (a) axial PCMI, (b) trapped fuel stack, (c) fuel relocation, and (d) effective fuel thermal expansion. Comparisons of cladding axial elongation measurements from two experiments with the corresponding FRAP-T6 calculations are presented

  8. Development of submersible axial pump for wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jeong Eui [Kangwon Nat' l Univ., Chuncheon (Korea, Republic of)

    2013-02-15

    This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade({beta}), the radial twist angle of a blade({alpha}) and the length of a blade ({iota}) on pump efficiency using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade({beta}) was the most sensible parameter on the pump efficiency. And the pump efficiency had a maximum at {beta}=20.deg, {alpha}=110.deg and {iota}=240mm.

  9. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  10. Axial displacements in external and internal implant-abutment connection.

    Science.gov (United States)

    Lee, Ji-Hye; Kim, Dae-Gon; Park, Chan-Jin; Cho, Lee-Ra

    2014-02-01

    The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  11. Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Uren Neal G

    2007-06-01

    Full Text Available Abstract Background Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.

  12. High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, P; De Leo, R; Nappi, E; Lustermann, W; Schinzel, D; Johnson, I; Renker, D; Albrecht, S

    2007-01-01

    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM).

  13. Dual-detection confocal fluorescence microscopy: fluorescence axial imaging without axial scanning.

    Science.gov (United States)

    Lee, Dong-Ryoung; Kim, Young-Duk; Gweon, Dae-Gab; Yoo, Hongki

    2013-07-29

    We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system. Axial information on fluorescent emitters can be measured by the axial response curve through the ratio of intensity signals. DDCFM can rapidly acquire a 3-D fluorescent image from a single two-dimensional scan with less phototoxicity and photobleaching than confocal fluorescence microscopy because no mechanical depth scans are needed. We demonstrated the feasibility of the proposed method by phantom studies.

  14. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  15. Fundamental characteristics of a synthesized light source for optical coherence tomography.

    Science.gov (United States)

    Sato, Manabu; Wakaki, Ichiro; Watanabe, Yuuki; Tanno, Naohiro

    2005-05-01

    We describe the fundamental characteristics of a synthesized light source (SLS) consisting of two low-coherence light sources to enhance the spatial resolution for optical coherence tomography (OCT). The axial resolution of OCT is given by half the coherence length of the light source. We fabricated a SLS with a coherence length of 2.3 microm and a side-lobe intensity of 45% with an intensity ratio of LED1:LED2 = 1:0.5 by combining two light sources, LED1, with a central wavelength of 691 nm and a spectral bandwidth of 99 nm, and LED2, with a central wavelength of 882 nm and a spectral bandwidth of 76 nm. The coherence length of 2.3 microm was 56% of the shorter coherence length in the two LEDs, which indicates that the axial resolution is 1.2 microm. The lateral resolution was measured at less than 4.4 microm by use of the phase-shift method and with a test pattern as a sample. The measured rough surfaces of a coin are illustrated and discussed.

  16. Interpretation of computed tomography imaging of the eye and orbit. A systematic approach

    Directory of Open Access Journals (Sweden)

    Naik Milind

    2002-01-01

    Full Text Available Computed tomography (CT has revolutionised the diagnosis and management of ocular and orbital diseases. The use of thin sections with multiplanar scanning (axial, coronal and sagittal planes and the possibility of three-dimensional reconstruction permits thorough evaluation. To make the most of this technique, users must familiarize themselves with the pertinent CT principles and terminology. The diagnostic yield is optimal when the ophthalmologist and radiologist collaborate in the radiodiagnostic workup. In this article we describe a systematic approach to the interpretation of ocular and orbital CT scans.

  17. sizing of wind powered axial flux permanent magnet alternator using

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... Keywords: Wind-Power, Axial flux, Axial Flux Permanent Machines (AFPM), Axial Flux Permanent Magnet ... energy for power generation, a high constraint is the .... arrangements as Single-Rotor Single-Stator Structure.

  18. Did the notochord evolve from an ancient axial muscle? The axochord hypothesis.

    Science.gov (United States)

    Brunet, Thibaut; Lauri, Antonella; Arendt, Detlev

    2015-08-01

    The origin of the notochord is one of the key remaining mysteries of our evolutionary ancestry. Here, we present a multi-level comparison of the chordate notochord to the axochord, a paired axial muscle spanning the ventral midline of annelid worms and other invertebrates. At the cellular level, comparative molecular profiling in the marine annelids P. dumerilii and C. teleta reveals expression of similar, specific gene sets in presumptive axochordal and notochordal cells. These cells also occupy corresponding positions in a conserved anatomical topology and undergo similar morphogenetic movements. At the organ level, a detailed comparison of bilaterian musculatures reveals that most phyla form axochord-like muscles, suggesting that such a muscle was already present in urbilaterian ancestors. Integrating comparative evidence at the cell and organ level, we propose that the notochord evolved by modification of a ventromedian muscle followed by the assembly of an axial complex supporting swimming in vertebrate ancestors. © 2015 The Authors. Bioessays published by WILEY Periodicals, Inc.

  19. Buoyant Helical Twin-Axial Wire Antenna

    Science.gov (United States)

    2016-11-15

    February 2017 The below identified patent application is available for licensing. Requests for information should be addressed to...300169 1 of 9 BUOYANT HELICAL TWIN-AXIAL WIRE ANTENNA CROSS REFERENCE TO OTHER PATENT APPLICATIONS [0001] This application is a divisional...application and claims the benefit of the filing date of United States Patent Application No. 14/280,889; filed on May 19, 2014; and entitled “Twin-Axial

  20. Axial forces in centrifugal compressor couplings

    Science.gov (United States)

    Ivanov, A. N.; Ivanov, N. M.; Yun, V. K.

    2017-08-01

    The article presents the results of the theoretical and experimental investigation of axial forces arising in the toothed and plate couplings of centrifugal compressor shaft lines. Additional loads on the thrust bearing are considered that can develop in the toothed couplings as a result of coupled rotors misalignment. Design relationships to evaluate the level of axial forces and recommendations for their reduction in the operating conditions are given.

  1. Chiral filter, axial charges and Gamow-Teller strengths

    International Nuclear Information System (INIS)

    Rho, M.

    1983-09-01

    The different ways that nuclear matter responds to the weak axial-vector current are interpreted in terms of modification of the ''vacuum'' in baryon-rich environments. The notion of ''chiral filter'' is introduced. Use of a ward identity is suggested. The Gamow-Teller quenching and the enhanced axial charge in O + O - transitions follow from this. I also discuss briefly possible relevance of the nucleon as a topological soliton configuration to the global property of nuclear axial response functions

  2. Fuel rod with axial regions of annular and standard fuel pellets

    International Nuclear Information System (INIS)

    Freeman, T.R.

    1991-01-01

    This patent describes a fuel rod for use in a nuclear reactor fuel assembly. It comprises: an elongated hollow cladding tube; a pair of end plugs connected to and sealing the cladding tube at opposite ends of thereof; and an axial stack of fuel pellets contained in and extending between the end plugs at the opposite ends of the tube, all of the fuel pellets contained in the tube being composed of fissile material being enriched above the level of natural enrichment; the fuel pellets in the stack thereof being provided in an arrangement of axial regions. The arrangement of axial regions including a pair of first axial regions defined respectively at the opposite ends of the pellet stack adjacent to the respective end plugs. The pellets in the first axial regions being identical in number and having annular configurations with an annulus of a first void size. The arrangement of axial regions also including another axial region defined between the first axial regions, some of the pellets in the another axial region having solid configurations

  3. Chiral lattice fermions, minimal doubling, and the axial anomaly

    International Nuclear Information System (INIS)

    Tiburzi, B. C.

    2010-01-01

    Exact chiral symmetry at finite lattice spacing would preclude the axial anomaly. In order to describe a continuum quantum field theory of Dirac fermions, lattice actions with purported exact chiral symmetry must break the flavor-singlet axial symmetry. We demonstrate that this is indeed the case by using a minimally doubled fermion action. For simplicity, we consider the Abelian axial anomaly in two dimensions. At finite lattice spacing and with gauge interactions, the axial anomaly arises from nonconservation of the flavor-singlet current. Similar nonconservation also leads to the axial anomaly in the case of the naieve lattice action. For minimally doubled actions, however, fine-tuning of the action and axial current is necessary to arrive at the anomaly. Conservation of the flavor nonsinglet vector current additionally requires the current to be fine-tuned. Finally, we determine that the chiral projection of a minimally doubled fermion action can be used to arrive at a lattice theory with an undoubled Dirac fermion possessing the correct anomaly in the continuum limit.

  4. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  5. Positron Emission Tomography with Three-Dimensional Reconstruction

    International Nuclear Information System (INIS)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of 'mobile pixels', which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs

  6. Evaluation of the Prevalence of Complete Isthmii in Permanent Teeth Using Cone-Beam Computed Tomography

    OpenAIRE

    Haghanifar, Sina; Moudi, Ehsan; Madani, Zahrasadat; Farahbod, Foroozan; Bijani, Ali

    2017-01-01

    Introduction: The current study aimed at determining the prevalence of complete isthmii in permanent teeth, using cone-beam computed tomography (CBCT) in a selected Iranian community. Methods and Materials: In this cross sectional study, 100 CBCT images (from 58 female and 42 male patients) including 1654 teeth (809 maxillary and 845 mandibular teeth) were evaluated. Each tooth root was evaluated in axial plane (interval, 0.1 mm; thickness, 0.1 mm) from the orifice to the apex and from the ap...

  7. Diagnostic scope of computer tomography in hip disease - Paget's disease, femoral head necrosis, coxarthrosis, coxarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nebel, G; Lingg, G; Reid, W

    1982-10-01

    The value of computer tomography was investigated in Paget's disease of the hip, femoral head necrosis (adult avascular and osteoradionecrosis), coxarthrosis and coxarthritis (bacterial and rheumatoid). The greatest value of CT is in the diagnosis of adult avascular necrosis of the femoral head and is valuable for localising the necrotic area in the axial plane. This is of value in planning surgical treatment (displacement osteotomy or endoprosthesis). In Paget's disease, coxarthrosis and coxarthritis, CT provides only additional or more precise information.

  8. Diagnostic scope of computer tomography in hip disease - Paget's disease, femoral head necrosis, coxarthrosis, coxarthritis

    International Nuclear Information System (INIS)

    Nebel, G.; Lingg, G.; Reid, W.

    1982-01-01

    The value of computer tomography was investigated in Paget's disease of the hip, femoral head necrosis (adult avascular and osteoradionecrosis), coxarthrosis and coxarthritis (bacterial and rheumatoid). The greatest value of CT is in the diagnosis of adult avascular necrosis of the femoral head and is valuable for localising the necrotic area in the axial plane. This is of value in planning surgical treatment (displacement osteotomy or endoprosthesis). In Paget's disease, coxarthrosis and coxarthritis, CT provides only additional or more precise information. (orig.) [de

  9. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  10. Axial Myopia and its Influence on Diabetic Retinopathy

    International Nuclear Information System (INIS)

    Tayyab, H.; Haider, M. A.; Bukhari, S. A. H.

    2014-01-01

    Objective: To evaluate the correlation between axial myopia and diabetic retinopathy. Study Design: Cross-sectional study. Place and Duration of Study: Eye Department of Postgraduate Medical Institute, Lahore General Hospital, from August 2012 to February 2013. Methodology: A total of 258 participants suffering from type-2 diabetic retinopathy were included. Axial length was measured by two optometrists using contact type ultrasound biometer. Colored retinal photographs, red free retinal photographs and Fundus Fluorescein Angiography (FFA) were performed on all patients using standard fundus camera. All fundus photographs and angiograms were independently reviewed and graded by two qualified vitreoretinal fellows. Results: Out of 258 patients, 163 were males (63.2%) and 95 (36.8%) were females. Average age of patients was 56.30 +- 7.57 years. Average axial length of right and left eyes were 23.16 mm and 23.15 mm respectively. There was statistically significant negative correlation between axial length and severity of diabetic retinopathy in the right eye, (Spearman correlation = -0.511, p = 0.0001) as well as the left eye (Spearman correlation = -0.522, p = 0.0001). Conclusion: There is a protective influence of longer axial length of globe on the stage and severity of diabetic retinopathy. This study may help in modifying the screening protocol for diabetic retinopathy amongst patients of differing axial lengths. (author)

  11. Transitions in axial morphology along the Southeast Indian Ridge

    Science.gov (United States)

    Ma, Ying; Cochran, James R.

    1996-07-01

    Shipboard bathymetric and magnetic profiles across the Southeast Indian Ridge (SEIR) were analyzed in order to examine the nature of along-axis variations in axial morphology at this intermediate spreading rate ridge. Three types of axial morphology are observed along the SEIR: an axial high, a shallow (200-700 m deep) axial valley and a deep (>1000 m deep) axial valley. An axial high is found to the east of the Australian-Antarctic Discordance (AAD) (east of 128°E) and between 82°E and 104°E. A shallow rift valley is found from 104°E to 114°E and from 82°E westward past the Amerstdam/St. Paul hotspot (ASP) to about 30°S, 75°E. Deep rift valleys are found from 114°E to 128°E in the vicinity of the AAD and from the Indian Ocean Triple Junction (IOTJ) at 25°S, 70°E to about 30°S, 75°E. The transition near 30°S occurs in an area of constant zero-age depth and does not appear to result from an increase in mantle temperature. It could be the result of the rapid increase in spreading rate along that portion of the SEIR. The most likely cause of the other transitions in axial morphology is variations in mantle temperature. The transitions between the different types of axial morphology are well defined and occur over a limited distance. Transitions in axial morphology are accompanied by significant changes in ridge flank topographic roughness. The transitions from axial valleys to axial highs are also accompanied by changes in the amplitude of the seafloor magnetic anomalies. Our observations suggest that there are distinct modes rather than a continuum of axial morphology on the SEIR and that there appears to be a "threshold" mechanism for a rapid change between different states of axial morphology. The ASP has only a limited influence on the SEIR. The ridge axis is marked by an axial valley for the entire distance from the IOTJ up to and past the ASP. The ridge axis becomes shallower as the ASP is approached from the northwest but only by about 300 m over

  12. An appraisal of golimumab in the treatment of severe, active nonradiographic axial spondyloarthritis

    Directory of Open Access Journals (Sweden)

    Paccou J

    2016-07-01

    Full Text Available Julien Paccou, René-Marc Flipo Department of Rheumatology, Lille University Hospital, Lille, France Abstract: Golimumab (Simponi® is a fully human tumor necrosis factor α inhibitor (TNFi antibody administered subcutaneously. In the European Union, golimumab is indicated for the treatment of adults with severe, active axial spondyloarthritis (axSpA, which includes both ankylosing spondylitis (AS and nonradiographic axSpA (nr-axSpA. In the US, it is indicated for the treatment of adults with active AS only. This article reviews the efficacy and tolerability of golimumab in nr-axSpA patients compared to other TNFi agents (adalimumab, infliximab, etanercept, and certolizumab pegol. In one ongoing, well-designed controlled study (GO-AHEAD, data at 16 weeks showed that treatment with golimumab (50 mg every 4 weeks was effective in improving the clinical signs and symptoms of disease in nr-axSpA patients. In addition, 16 weeks of treatment with golimumab reduced inflammation in the sacroiliac joints and spine in patients with nr-axSpA. Moreover, objective evidence of active inflammation at baseline, such as a positive magnetic resonance imaging scan and/or an elevated CRP level, was a good predictor of treatment response to golimumab. Golimumab was generally well tolerated in this study, with a tolerability profile consistent with that seen in previous clinical trials for other indications. Although additional long-term data are needed, current evidence indicates that golimumab is an effective option for the treatment of nr-axSpA. However, in the absence of comparative head-to-head trials, there is no recommended hierarchy for the first prescription of a TNFi agent for the treatment of either nr-axSpA or AS. Keywords: axial spondyloarthritis, nonradiographic axial spondyloarthritis, ankylosing spondylitis, golimumab, tumor necrosis factor α inhibitor, therapy

  13. The Axially Symmetric One-Monopole

    International Nuclear Information System (INIS)

    Wong, K.-M.; Teh, Rosy

    2009-01-01

    We present new classical generalized one-monopole solution of the SU(2) Yang-Mills-Higgs theory with the Higgs field in the adjoint representation. We show that this solution with θ-winding number m = 1 and φ-winding number n = 1 is an axially symmetric generalization of the 't Hooft-Polyakov one-monopole. We construct this axially symmetric one-monopole solution by generalizing the large distance asymptotic solutions of the 't Hooft-Polyakov one-monopole to the Jacobi elliptic functions and solving the second order equations of motion numerically when the Higgs potential is vanishing. This solution is a non-BPS solution.

  14. «FLARES» IN AXIAL SPONDYLOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Sh. F. Erdes

    2016-01-01

    Full Text Available The clear definition of the concept of «flare in axial spondyloarthritis» is of paramount importance for clinical trials and routine practice in particular. It will be able to unify the characteristics of outcomes over a particular period of time on the one hand and to standardize therapeutic approaches on the other. On 4 February 2016, the journal Annals of Rheumatic Diseases published the on-line paper «Preliminary definitions of 'flare' in axial spondyloarthritis, based on pain, BASDAI and ASDAS-CRP: an ASAS initiative» by L. Gossec et al., which was devoted to this topic.

  15. A comparison of radiography, computed tomography, and magnetic resonance imaging for the diagnosis of palmar process fractures in foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; Koblik, P.D.; Freeman, D.M.; Pool, R.R.; O'Brien, T.R.

    1995-01-01

    The relative sensitivity of radiography, computed tomography, and magnetic resonance imaging for detecting palmar process fractures of the distal phalanx in foals was determined and the imaging findings were compared with histomorphologic evaluations of the palmar processes. Compared to radiography, computed tomography and magnetic resonance imaging did not improve the sensitivity for detection of palmar process fractures. Statistical agreement for palmar process fracture diagnosis was excellent among the three imaging modalities. Histomorphologic evaluations were more sensitive for diagnosis of palmar process fracture than any of the imaging modalities. Three-dimensional image reconstructions and volume measurements of distal phalanges and palmar process fracture fragments from computed tomography studies provided more complete anatomical information than radiography. Magnetic resonance imaging confirmed that the deep digital flexor tendon insertion on the distal phalanx is immediately axial to the site where palmar process fractures occur, and differentiated cartilage, bone, and soft tissue structures of the hoof

  16. Classification of temporal bone pneumatization based on sigmoid sinus using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Han, S.-J. [Department of Otorhinolaryngology, National Health Insurance Corporation Ilsan Hospital, Seoul (Korea, Republic of); Song, M.H. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Kim, J. [Department of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, W.-S. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Lee, H.-K. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of)], E-mail: hoki@yuhs.ac

    2007-11-15

    Aim: To analyse several reference structures using axial computed tomography (CT) imaging of the temporal bone, which may reflect pneumatization of the entire temporal bone by statistical correlation to the actual volume of the temporal bone measured using three-dimensional reconstruction. Materials and methods: One hundred and sixteen temporal bones were studied, comprising 48 with normal findings and 68 sides showing chronic otitis media or temporal bone fracture. After measuring the volume of temporal bone air cells by the volume rendering technique using three-dimensional reconstruction images, classification of temporal bone pneumatization was performed using various reference structures on axial images to determine whether significant differences in the volume of temporal bone air cells could be found between the groups. Results: When the sigmoid sinus at the level of the malleoincudal complex was used in the classification, there were statistically significant differences between the groups that correlated with the entire volume of the temporal bone. Grouping based on the labyrinth and the ascending carotid artery showed insignificant differences in volume. Furthermore, there was no significant correlation between the cross-sectional area of the antrum and the entire volume of the temporal bone. Conclusion: The degree of pneumatization of temporal bone can be estimated easily by the evaluation of the air cells around the sigmoid sinus on axial CT images.

  17. New classes of bi-axially symmetric solutions to four-dimensional Vasiliev higher spin gravity

    Energy Technology Data Exchange (ETDEWEB)

    Sundell, Per; Yin, Yihao [Departamento de Ciencias Físicas, Universidad Andres Bello,Republica 220, Santiago de Chile (Chile)

    2017-01-11

    We present new infinite-dimensional spaces of bi-axially symmetric asymptotically anti-de Sitter solutions to four-dimensional Vasiliev higher spin gravity, obtained by modifications of the Ansatz used in https://arxiv.org/abs/1107.1217, which gave rise to a Type-D solution space. The current Ansatz is based on internal semigroup algebras (without identity) generated by exponentials formed out of the bi-axial symmetry generators. After having switched on the vacuum gauge function, the resulting generalized Weyl tensor is given by a sum of generalized Petrov type-D tensors that are Kerr-like or 2-brane-like in the asymptotic AdS{sub 4} region, and the twistor space connection is smooth in twistor space over finite regions of spacetime. We provide evidence for that the linearized twistor space connection can be brought to Vasiliev gauge.

  18. Bone changes of mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Un; Kim, Hyung Seop; Song, Ju Seop; Kim, Kyoung A; Koh, Kwang Joon [Chonbuk National Univ., Chonju (Korea, Republic of)

    2007-09-15

    To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibualr disorder (TMD) patients. 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra-and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Osteopathy (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior surface of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78{sub 0}.84), but interobserver agreement was fair (k=0.45). CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  19. Bone changes of mandibular condyle using cone beam computed tomography

    International Nuclear Information System (INIS)

    Lee, Ji Un; Kim, Hyung Seop; Song, Ju Seop; Kim, Kyoung A; Koh, Kwang Joon

    2007-01-01

    To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibualr disorder (TMD) patients. 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra-and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Osteopathy (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior surface of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78 0 .84), but interobserver agreement was fair (k=0.45). CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images

  20. Improvement in Scoliosis Top View: Evaluation of Vertebrae Localization in Scoliotic Spine-Spine Axial Presentation

    Directory of Open Access Journals (Sweden)

    Paweł Główka

    2016-11-01

    Full Text Available Morphological analysis of the scoliotic spine is based on two-dimensional X-rays: coronal and sagittal. The three-dimensional character of scoliosis has raised the necessity for analyzing scoliosis in three planes. We proposed a new user-friendly method of graphical presentation of the spine in the third plane–the Spine Axial Presentation (SAP. Eighty-five vertebrae of patients with scoliosis were analyzed. Due to different positions during X-rays (standing and computer tomography (CT (supine, the corresponding measurements cannot be directly compared. As a solution, a software creating Digital Reconstructed Radiographs (DRRs from CT scans was developed to replace regular X-rays with DRRs. Based on the measurements performed on DRRs, the coordinates of vertebral bodies central points were defined. Next, the geometrical centers of vertebral bodies were determined on CT scans. The reproducibility of measurements was tested with Intraclass Correlation Coefficient (ICC, using p = 0.05. The intra-observer reproducibility and inter-observer reliability for vertebral body central point’s coordinates (x, y, z were high for results obtained based on DRRs and CT scans, as well as for comparison results obtained based on DRR and CT scans. Based on two standard radiographs, it is possible to localize vertebral bodies in 3D space. The position of vertebral bodies can be present in the Spine Axial Presentation.

  1. Axial weak currents in the Wess-Zumino term

    International Nuclear Information System (INIS)

    Fujikawa, Kazuo.

    1985-03-01

    The conventional axial gauging of the Wess-Zumino term leads to the results which do not necessarily agree with the expectations on the basis of quark level Ward-Takahashi identities. This discrepancy arises from the fact that the quark level anomalous identities reflect the short distance structure of QCD, whereas the gauging of the Wess-Zumino term reflects the axial symmetry in the spontaneously broken chiral phase. The low energy theorem for axial weak fields is not sharply defined, in contrast to the case of vector fields where no such complications arise. (author)

  2. Three-dimensional ophthalmic optical coherence tomography with a refraction correction algorithm

    Science.gov (United States)

    Zawadzki, Robert J.; Leisser, Christoph; Leitgeb, Rainer; Pircher, Michael; Fercher, Adolf F.

    2003-10-01

    We built an optical coherence tomography (OCT) system with a rapid scanning optical delay (RSOD) line, which allows probing full axial eye length. The system produces Three-dimensional (3D) data sets that are used to generate 3D tomograms of the model eye. The raw tomographic data were processed by an algorithm, which is based on Snell"s law to correct the interface positions. The Zernike polynomials representation of the interfaces allows quantitative wave aberration measurements. 3D images of our results are presented to illustrate the capabilities of the system and the algorithm performance. The system allows us to measure intra-ocular distances.

  3. Colon dissection: a new three-dimensional reconstruction tool for computed tomography colonography

    International Nuclear Information System (INIS)

    Roettgen, R.; Fischbach, F.; Plotkin, M.; Herzog, H.; Freund, T.; Schroeder, R. J.; Felix, R.

    2005-01-01

    Purpose: To improve the sensitivity of computed tomography (CT) colonography in the detection of polyps by comparing the 3D reconstruction tool 'colon dissection' and endoluminal view (virtual colonoscopy) with axial 2D reconstructions. Material and Methods: Forty-eight patients (22 M, 26 F, mean age 57±21) were studied after intra-anal air insufflation in the supine and prone positions using a 16-slice helical CT (16x0.625 mm, pitch 1.7; detector rotation time 0.5 s; 160 mAs und 120 kV) and conventional colonoscopy. Two radiologists blinded to the results of the conventional colonoscopy analyzed the 3D reconstruction in virtual-endoscopy mode, in colon-dissection mode, and axial 2D slices. Results: Conventional colonoscopy revealed a total of 35 polyps in 15 patients; 33 polyps were disclosed by CT methods. Sensitivity and specificity for detecting colon polyps were 94% and 94%, respectively, when using the 'colon dissection', 89% and 94% when using 'virtual endoscopy', and 62% and 100% when using axial 2D reconstruction. Sensitivity in relation to the diameter of colon polyps with 'colon dissection', 'virtual colonoscopy', and axial 2D-slices was: polyps with a diameter >5.0 mm, 100%, 100%, and 71%, respectively; polyps with a diameter of between 3 and 4.9 mm, 92%, 85%, and 46%; and polyps with a diameter <3 mm, 89%, 78%, and 56%. The difference between 'virtual endoscopy' and 'colon dissection' in diagnosing polyps up to 4.9 mm in diameter was statistically significant. Conclusion: 3D reconstruction software 'colon dissection' improves sensitivity of CT colonography compared with the endoluminal view

  4. Anatomic variants of interest in endoscopic sinus surgery: role of computed tomography

    International Nuclear Information System (INIS)

    Alonso, S.; Arenas, J.; Fernandez, F.; Gil, S.; Guirau, M. D.

    2000-01-01

    The detailed radiological study of the anatomy of the nasal cavities and paranasal sinus is essential prior to endoscopic sinus surgery since, on the one hand, it discloses the extent of the disease and, on the other hand, it aids in the detection of the numerous anatomic variants, some of which are of great interest to the endoscopic as the lack of preoperative knowledge of them may increase the risk of complications. the objective of the present report is to review these variants, stressing those that may be associated with a greater surgical risk. Although coronal computed tomography is the technique of choice for pre endoscopy examination, certain structures and anatomic variants are better viewed in axial images. These exceptions include anterior and posterior walls of the frontal sinuses, the anatomic relationships between posterior ethmoid complex and the sphenoid sinus, the relationships between the sphenoid sinus and the optic nerve, and the detection of Onodi cells. Thus, we recommend that the radiological examination include both coronal and axial images. (Author) 16 refs

  5. Magmatic controls on axial relief and faulting at mid-ocean ridges

    Science.gov (United States)

    Liu, Zhonglan; Buck, W. Roger

    2018-06-01

    Previous models do not simultaneously reproduce the observed range of axial relief and fault patterns at plate spreading centers. We suggest that this failure is due to the approximation that magmatic dikes open continuously rather than in discrete events. During short - lived events, dikes open not only in the strong axial lithosphere but also some distance into the underlying weaker asthenosphere. Axial valley relief affects the partitioning of magma between the lithosphere and asthenosphere during diking events. The deeper the valley, the more magma goes into lithospheric dikes in each event and so the greater the average opening rate of those dikes. The long-term rate of lithospheric dike opening controls faulting rate and axial depth. The feedback between axial valley depth D and lithospheric dike opening rate allows us to analytically relate steady-state values of D to lithospheric thickness HL and crustal thickness HC. A two-dimensional model numerical model with a fixed axial lithospheric structure illustrates the analytic model implications for axial faulting. The predictions of this new model are broadly consistent with global and segment-scale trends of axial depth and fault patterns with HL and HC.

  6. Radial loads and axial thrusts on centrifugal pumps

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The proceedings of a seminar organised by the Power Industries Division of the IMechE are presented in this text. Complete contents: Review of parameters influencing hydraulic forces on centrifugal impellers; The effect of fluid forces at various operation conditions on the vibrations of vertical turbine pumps; A review of the pump rotor axial equilibrium problem - some case studies; Dynamic hydraulic loading on a centrifugal pump impeller; Experimental research on axial thrust loads of double suction centrifugal pumps; A comparison of pressure distribution and radial loads on centrifugal pumps; A theoretical and experimental investigation of axial thrusts within a multi-stage centrifugal pump

  7. The effects of initial rise and axial loads on MEMS arches

    KAUST Repository

    Tella, Sherif Adekunle

    2017-04-07

    Arch microbeams have been utilized and proposed for many uses over the past few years due to their large tunability and bistability. However, recent experimental data have shown different mechanical behavior of arches when subjected to axial loads. This paper aims to investigate in depth the influence of the competing effects of initial rise and axial loads on the mechanical behavior of micromachined arches; mainly their static deflection and resonant frequencies. Based on analytical solutions, the static response and eigenvalue problems are analyzed for various values of initial rises and axial loads. Universal curves showing the variation of the first three resonance frequencies of the arch are generated for various values of initial rise under both tensile and compressive axial loads. This study shows that increasing the tensile or compressive axial loads for different values of initial rise may lead to either increase in the stiffness of the beam or initial decrease in the stiffness, which later increases as the axial load is increased depending on the dominant effect of the initial rise of the arch and the axial load. The obtained universal curves represent useful design tools to predict the tunability of arches under axial loads for various values of initial rises. The use of the universal curves is demonstrated with an experimental case study. Analytical formulation is developed to predict the point of minimum where the trend of the resonance frequency versus axial loads changes qualitatively due to the competing effects of axial loads and initial curvature.

  8. Fourier phase in Fourier-domain optical coherence tomography

    Science.gov (United States)

    Uttam, Shikhar; Liu, Yang

    2015-01-01

    Phase of an electromagnetic wave propagating through a sample-of-interest is well understood in the context of quantitative phase imaging in transmission-mode microscopy. In the past decade, Fourier-domain optical coherence tomography has been used to extend quantitative phase imaging to the reflection-mode. Unlike transmission-mode electromagnetic phase, however, the origin and characteristics of reflection-mode Fourier phase are poorly understood, especially in samples with a slowly varying refractive index. In this paper, the general theory of Fourier phase from first principles is presented, and it is shown that Fourier phase is a joint estimate of subresolution offset and mean spatial frequency of the coherence-gated sample refractive index. It is also shown that both spectral-domain phase microscopy and depth-resolved spatial-domain low-coherence quantitative phase microscopy are special cases of this general theory. Analytical expressions are provided for both, and simulations are presented to explain and support the theoretical results. These results are further used to show how Fourier phase allows the estimation of an axial mean spatial frequency profile of the sample, along with depth-resolved characterization of localized optical density change and sample heterogeneity. Finally, a Fourier phase-based explanation of Doppler optical coherence tomography is also provided. PMID:26831383

  9. Fourier phase in Fourier-domain optical coherence tomography.

    Science.gov (United States)

    Uttam, Shikhar; Liu, Yang

    2015-12-01

    Phase of an electromagnetic wave propagating through a sample-of-interest is well understood in the context of quantitative phase imaging in transmission-mode microscopy. In the past decade, Fourier-domain optical coherence tomography has been used to extend quantitative phase imaging to the reflection-mode. Unlike transmission-mode electromagnetic phase, however, the origin and characteristics of reflection-mode Fourier phase are poorly understood, especially in samples with a slowly varying refractive index. In this paper, the general theory of Fourier phase from first principles is presented, and it is shown that Fourier phase is a joint estimate of subresolution offset and mean spatial frequency of the coherence-gated sample refractive index. It is also shown that both spectral-domain phase microscopy and depth-resolved spatial-domain low-coherence quantitative phase microscopy are special cases of this general theory. Analytical expressions are provided for both, and simulations are presented to explain and support the theoretical results. These results are further used to show how Fourier phase allows the estimation of an axial mean spatial frequency profile of the sample, along with depth-resolved characterization of localized optical density change and sample heterogeneity. Finally, a Fourier phase-based explanation of Doppler optical coherence tomography is also provided.

  10. Contribution to regularizing iterative method development for attenuation correction in gamma emission tomography

    International Nuclear Information System (INIS)

    Cao, A.

    1981-07-01

    This study is concerned with the transverse axial gamma emission tomography. The problem of self-attenuation of radiations in biologic tissues is raised. The regularizing iterative method is developed, as a reconstruction method of 3 dimensional images. The different steps from acquisition to results, necessary to its application, are described. Organigrams relative to each step are explained. Comparison notion between two reconstruction methods is introduced. Some methods used for the comparison or to bring about the characteristics of a reconstruction technique are defined. The studies realized to test the regularizing iterative method are presented and results are analyzed [fr

  11. Quasi-renormalization of the axial vector model

    International Nuclear Information System (INIS)

    Schweda, M.

    1979-01-01

    Using the regulator-free BPHZL renormalization scheme the problem of anomalies in a massive axial vector meson model is reinvestigated. The Adler-Bardeen-Bell-Jackiw anomaly introduces some impressive modifications: the nontrivial self-energy and the counterterm of the longitudinal part of the axial vector field depend on the anomaly via the anomalous Ward identity. The investigations are based on a Fermi-type gauge. (author)

  12. Effect of axial heat flux distribution on CHF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol

    2000-10-01

    Previous investigations for the effect of axial heat flux distributions on CHF and the prediction methods are reviewed and summarized. A total of 856 CHF data in a tube with a non-uniform axial heat flux distribution has been compiled from the articles and analyzed using the 1995 Groeneveld look-up table. The results showed that two representative correction factors, K5 of the look-up table and Tongs F factor, can be applied to describe the axial heat flux distribution effect on CHF. However, they overpredict slightly the measured CHF, depending on the quality and flux peak shape. Hence, a corrected K5 factor, which accounts for the axial heat flux distribution effect is suggested to correct these trends. It predicted the CHF power for the compiled data with an average error of 1.5% and a standard deviation of 10.3%, and also provides a reasonable prediction of CHF locations.

  13. Unilateral atlanto-axial fractures in near side impact collisions: An under recognized entity in cervical trauma

    Directory of Open Access Journals (Sweden)

    Andrew M Lozen

    2014-01-01

    Full Text Available Objective: Nearside impact collisions presenting with lateral mass fractures of atlanto-axial vertebrae contralateral to the impact site represents a rare fracture pattern that does not correlate with previously described injury mechanism. We describe our clinical experience with such fractures and propose a novel description of biomechanical forces involved in this unique injury pattern. The findings serve to alert clinicians to potentially serious consequences of associated unrecognized and untreated vertebral artery injury. Material and Methods : In addition to describing our clinical experience with three of these fractures, a review of Crash Injury Research and Engineering Network (CIREN database was conducted to further characterize such fractures. A descriptive analysis of three recent lateral mass fractures of the atlanto-axial segment is coupled with a review of the CIREN database. A total of 4047 collisions were screened for unilateral fractures of atlas or axis. Information was screened for side of impact and data regarding impact velocity, occupant injuries and use of restraints. Results: Following screening of unilateral fractures of atlas and axis for direct side impacts, 41 fractures were identified. Cross referencing these cases for occurrence contralateral to side of impact identified four such fractures. Including our recent clinical experience, seven injuries were identified: Five C1 and two C2 fractures. Velocity ranged from 14 to 43 km/h. Two associated vertebral artery injuries were identified. Conclusions: Complexity of the atlanto-axial complex is responsible for a sequence of events that define load application in side impacts. This study demonstrates the vulnerability of vertebral artery to injury under unique translational forces and supports the use or routine screening for vascular injury. Diminished sensitivity of plain radiography in identifying these injuries suggests that computerized tomography should be used in

  14. Continuous millennial decrease of the Earth's magnetic axial dipole

    Science.gov (United States)

    Poletti, Wilbor; Biggin, Andrew J.; Trindade, Ricardo I. F.; Hartmann, Gelvam A.; Terra-Nova, Filipe

    2018-01-01

    Since the establishment of direct estimations of the Earth's magnetic field intensity in the first half of the nineteenth century, a continuous decay of the axial dipole component has been observed and variously speculated to be linked to an imminent reversal of the geomagnetic field. Furthermore, indirect estimations from anthropologically made materials and volcanic derivatives suggest that this decrease began significantly earlier than direct measurements have been available. Here, we carefully reassess the available archaeointensity dataset for the last two millennia, and show a good correspondence between direct (observatory/satellite) and indirect (archaeomagnetic) estimates of the axial dipole moment creating, in effect, a proxy to expand our analysis back in time. Our results suggest a continuous linear decay as the most parsimonious long-term description of the axial dipole variation for the last millennium. We thus suggest that a break in the symmetry of axial dipole moment advective sources occurred approximately 1100 years earlier than previously described. In addition, based on the observed dipole secular variation timescale, we speculate that the weakening of the axial dipole may end soon.

  15. Choroidal thinning in high myopia measured by optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Ikuno Y

    2013-05-01

    Full Text Available Yasushi Ikuno, Satoko Fujimoto, Yukari Jo, Tomoko Asai, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: To investigate the rate of choroidal thinning in highly myopic eyes.Patients and methods: A retrospective observational study of 37 eyes of 26 subjects (nine males and 17 females, mean age 39.6 ± 7.7 years with high myopia but no pathologies who had undergone spectral domain optical coherence tomography and repeated the test 1 year later (1 ± 0.25 year at Osaka University Hospital, Osaka, Japan. Patients older than 50 years with visual acuity worse than 20/40 or with whitish chorioretinal atrophy involving the macula were excluded. Two masked raters measured the choroidal thicknesses (CTs at the foveda, 3 mm superiorly, inferiorly, temporally, and nasally on the images and averaged the values. The second examination was about 365 days after the baseline examination. The CT reduction per year (CTRPY was defined as (CT 1 year after - baseline CT/days between the two examinations × 365. The retinal thicknesses were also investigated.Results: The CTRPY at the fovea was −1.0 ± 22.0 µm (range –50.2 to 98.5 at the fovea, –6.5 ± 24.3 µm (range −65.8 to 90.2 temporally, –0.5 ± 22.3 µm (range –27.1 to 82.5 nasally, –9.7 ± 21.7 µm (range –40.1 to 60.1 superiorly, and –1.4 ± 25.5 µm (range –85.6 to 75.2 inferiorly. There were no significant differences in the CTRPY at each location (P = 0.34. The CT decreased significantly (P < 0.05 only superiorly. The superior CTRPY was negatively correlated with the axial length (P < 0.05. The retinal thickness at the fovea did not change. Stepwise analysis for CTRPY selected axial length (P = 0.04, R2 = 0.13 and age (P = 0.08, R2 = 0.21 as relevant factors.Conclusions: The highly myopic choroid might gradually thin and be affected by many factors. Location and axial length are key factors to regulate the rate of choroidal

  16. Dechanneling function for relativistic axially channeled electrons

    International Nuclear Information System (INIS)

    Muralev, V.A.; Telegin, V.I.

    1981-01-01

    Behaviour of the x(t) dechanneling function depending on the depth is theoretically studied. Theoretical consideration of x(t) for axial channeled relativistic electrons in anisotropic medium results in two-dimensional kinetic equation with mixed derivatives of the parabolic type. The kinetic equation in the approximation of the continuous Lindchard model for relativistic axial channeled electrons is numerically solved. The depth dependence of the x(t) dechanneling function is obtained [ru

  17. Singlet axial constant from QCD sum rules

    International Nuclear Information System (INIS)

    Belitskij, A.V.; Teryaev, O.V.

    1995-01-01

    We analyze the singlet axial form factor of the proton for small momentum transferred in the framework of QCD sum rules using the interpolating nucleon current which explicitly accounts for the gluonic degrees of freedom. As the result we come to the quantitative prediction of the singlet axial constant. It is shown that the bilocal power corrections play the most important role in the analysis. 21 refs., 3 figs

  18. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  19. Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.

    Science.gov (United States)

    Watanabe, Yuuki; Maeno, Seiya; Aoshima, Kenji; Hasegawa, Haruyuki; Koseki, Hitoshi

    2010-09-01

    The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.

  20. Axial clamp for nuclear reactor head penetration conoseal joints

    International Nuclear Information System (INIS)

    Hackley, T.A.

    1986-01-01

    A method for forming a sealed coupling between two bodies each body presenting an abutment surface, the bodies being arranged so that their respective abutment surfaces are axially adjacent one another and define a space therebetween in which a deformable gasket is disposed. An axial external force is applied to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies and the bodies are immobilized relative to one another while the external force is being applied to the bodies so that sufficient compression will be maintained by the abutment surfaces to preserve the integrity of the seal when the external axial force is withdrawn. The external axial force is then withdrawn, leaving the two bodies coupled together via the seal. (author)

  1. Axial Dispersion during Hanford Saltcake Washing

    International Nuclear Information System (INIS)

    Josephson, Gary B.; Geeting, John GH; Lessor, Delbert L.; Barton, William B.

    2006-01-01

    Clean up of Hanford salt cake wastes begins with dissolution retrieval of the sodium rich salts that make up the dominant majority of mass in the tanks. Water moving through the porous salt cake dissolves the soluble components and also displaces the soluble radionuclides (e.g. 137Cs and 99TcO4- ). The separation that occurs from this displacement, known as Selective dissolution, is an important component in Hanford?s pretreatment of low activity wastes for subsequent Supplemental treatment. This paper describes lab scale testing conducted to evaluate Selective dissolution of cesium from non-radioactive Hanford tank 241-S-112 salt cake simulant containing the primary chemicals found the actual tank. An modified axial dispersion model with increasing axial dispersion was developed to predict cesium removal. The model recognizes that water dissolves the salt cake during washing, which causes an increase in the axial dispersion during the wash. This model was subsequently compared with on-line cesium measurements from the retrieval of tank 241-S-112. The model had remarkably good agreement with both the lab scale and full scale data

  2. Combination of optical coherence tomography and reflectometry technique for eye measurement

    Science.gov (United States)

    Lu, Hui; Wang, Michael R.

    2013-03-01

    A spectral domain optical coherence tomography system is integrated with an optical reflectometer to provide dualfunctional eye measurement. The system is capable of performing anterior segment imaging and tear film thickness evaluation at the same time. The axial resolution of the anterior segment imaging is 6μm while for tear film thickness measurement the resolution is about 21 nm. We use the integrated device to examine a model eye with artificial tear film. Structures such as the cornea, the ciliary muscle, and the front boundary of the crystalline lens are clearly visible. Artificial tear film thickness is determined simultaneously with anterior segment imaging. The integrated device is also flexible for separated anterior segment imaging or tear thickness evaluation.

  3. [Myopia: frequency of lattice degeneration and axial length].

    Science.gov (United States)

    Martín Sánchez, M D; Roldán Pallarés, M

    2001-05-01

    To evaluate the relationship between lattice retinal degeneration and axial length of the eye in different grades of myopia. A sample of 200 eyes from 124 myopic patients was collected by chance. The average age was 34.8 years (20-50 years) and the myopia was between 0.5 and 20 diopters (D). The eyes were grouped according to the degree of refraction defect, the mean axial length of each group (Scan A) and the frequency of lattice retinal degeneration and the relationship between these variables was studied. The possible influence of age on our results was also considered. For the statistical analysis, the SAS 6.07 program with the variance analysis for quantitative variables, and chi(2) test for qualitative variables with a 5% significance were used. A multivariable linear regression model was also adjusted. The highest frequency of lattice retinal degeneration occurred in those myopia patients having more than 15 D, and also in the group of myopia patients between 3 and 6 D, but this did not show statistical significance when compared with the other myopic groups. If the axial length is assessed, a greater frequency of lattice retinal degeneration is also found when the axial length is 25-27 mm and 29-30 mm, which correspond, respectively, to myopias between 3-10 D and more than 15 D. When the multivariable linear regression model was adjusted, the axial length showed the existence of lattice retinal degeneration (beta 0.41 mm; p=0.08) adjusted by the number of diopters (beta 0.38 mm; plattice retinal degeneration was found for myopias with axial eye length between 29-30 mm (more than 15 D), and 25-27 mm (between 3-10 D).

  4. Investigation of angular and axial smoothing of PET data

    International Nuclear Information System (INIS)

    Daube-Witherspoon, M.E.; Carson, R.E.

    1996-01-01

    Radial filtering of emission and transmission data is routinely performed in PET during reconstruction in order to reduce image noise. Angular smoothing is not typically done, due to the introduction of a non-uniform resolution loss; axial filtering is also not usually performed on data acquired in 2D mode. The goal of this paper was to assess the effects of angular and axial smoothing on noise and resolution. Angular and axial smoothing was incorporated into the reconstruction process on the Scanditronix PC2048-15B brain PET scanner. In-plane spatial resolution and noise reduction were measured for different amounts of radial and angular smoothing. For radial positions away from the center of the scanner, noise reduction and degraded tangential resolution with no loss of radial resolution were seen. Near the center, no resolution loss was observed, but there was also no reduction in noise for angular filters up to a 7 degrees FWHM. These results can be understood by considering the combined effects of smoothing projections across rows (angles) and then summing (backprojecting). Thus, angular smoothing is not optimal due to its anisotropic noise reduction and resolution degradation properties. However, uniform noise reduction comparable to that seen with radial filtering can be achieved with axial smoothing of transmission data. The axial results suggest that combined radial and axial transmission smoothing could lead to improved noise characteristics with more isotropic resolution degradation

  5. Axial clamp for nuclear reactor head penetration conoseal joints

    International Nuclear Information System (INIS)

    Hackley, T.A.

    1987-01-01

    A method is described for forming a sealed coupling between two bodies, each body presenting an annular abutment surface. The respective bodies are arranged so that their respective annular abutment surfaces are axially adjacent one another, defining a space therebetween, wherein a deformable gasket is disposed within the space. The method comprises: providing one of the bodies with an annular projection; providing the other body with threads for receiving an annular locknut which can be tightened to bear against the annular projection of the one body; applying an external axial forced to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies; immobilizing the bodies relative to one another while the external force is being applied to the bodies by hand-tightening an annular locknut via the threads of the other body until the locknut abuts the annular projection of the one body, substantially preventing relative axial movement between the bodies when the external axial force is withdrawn; and withdrawing the external axial force applied to the bodies, leaving the two bodies coupled together via the seal

  6. Three-dimensional magnetotelluric axial anisotropic forward modeling and inversion

    Science.gov (United States)

    Cao, Hui; Wang, Kunpeng; Wang, Tao; Hua, Boguang

    2018-06-01

    Magnetotelluric (MT) data has been widely used to image underground electrical structural. However, when the significant axial resistivity anisotropy presents, how this influences three-dimensional MT data has not been resolved clearly yet. We here propose a scheme for three-dimensional modeling of MT data in presence of axial anisotropic resistivity, where the electromagnetic fields are decomposed into primary and secondary components. A 3D staggered-grid finite difference method is then used to resolve the resulting 3D governing equations. Numerical tests have completed to validate the correctness and accuracy of the present algorithm. A limited-memory Broyden-Fletcher-Goldfarb-Shanno method is then utilized to realize the 3D MT axial anisotropic inversion. The testing results show that, compared to the results of isotropic resistivity inversion, taking account the axial anisotropy can much improve the inverted results.

  7. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  8. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  9. Generalized dynamic model and control of ambiguous mono axial vehicle robot

    Directory of Open Access Journals (Sweden)

    Frantisek Duchon

    2016-09-01

    Full Text Available This article deals with the novel concept of ambiguous mono axial vehicle robot. Such robot is a combination of Segway and dicycle, which utilizes the advantages of each chassis. The advantage of dicycle is lower energy consumption during the movement and the higher safety of carried payload. The movable platform inside the ambiguous mono axial vehicle allows using the various sensors or devices. This will change the ambiguous mono axial vehicle to the Segway type robot. Both these modes are necessary to control in the stable mode to ensure the safety of the ambiguous mono axial vehicle’s movement. The main contents of the article contain description of generalized dynamic model of ambiguous mono axial vehicle and related control of ambiguous mono axial vehicle. The proposal is unique in that the same controller is used for both modes. Several simulations verify proposed control schemes and identified parameters. Moreover, the dicycle type of platform has never been used in robotics and that is another novelty.

  10. The Formation of Laurentia: Evidence from Shear Wave Splitting and Seismic Tomography

    Science.gov (United States)

    Liddell, M. V.; Bastow, I. D.; Rawlinson, N.; Darbyshire, F. A.; Gilligan, A.

    2017-12-01

    The northern Hudson Bay region of Canada comprises several Archean cratonic nuclei, assembled by Paleoproterozoic orogenies including the 1.8 Ga Trans-Hudson Orogen (THO) and Rinkian-Nagssugtoqidian Orogen (NO). Questions remain about how similar in scale and nature these orogens were compared to modern orogens like the Himalayas. Also in question is whether the thick Laurentian cratonic root below Hudson Bay is stratified, with a seismically-fast Archean core underlain by a lower, younger, thermal layer. We investigate these problems via shear-wave splitting and teleseismic tomography using up to 25 years of data from 65 broadband seismic stations across northern Hudson Bay. The results of the complementary studies comprise the most comprehensive study to date of mantle seismic velocity and anisotropy in northern Laurentia. Splitting parameter patterns are used to interpret multiple layers, lithospheric boundaries, dipping anisotropy, and deformation zone limits for the THO and NO. Source-side waveguide effects from Japan and the Aleutian trench are observed despite the tomographic data being exclusively relative arrival time. Mitigating steps to ensure data quality are explained and enforced. In the Hudson Strait, anisotropic fast directions (φ) generally parallel the THO, which appears in tomographic images as a strong low velocity feature relative to the neighbouring Archean cratons. Several islands in northern Hudson Bay show short length-scale changes in φ coincident with strong velocity contrasts. These are interpreted as distinct lithospheric blocks with unique deformational histories, and point to a complex, rather than simple 2-plate, collisional history for the THO. Strong evidence is presented for multiple anisotropic layers beneath Archean zones, consistent with the episodic development model of cratonic keels (e.g., Yuan & Romanowicz 2010). We show via both tomographic inversion models and SKS splitting patterns that southern Baffin Island was

  11. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  12. The spin of the proton and the axial anomaly

    International Nuclear Information System (INIS)

    Hatsuda, T.; Zahed, I.

    1989-01-01

    We show that a consistent treatment of the abelian axial anomaly in a two-phase model of the proton yields a flavor singlet axial current that is saturated by the anomaly at Q 2 =0 in the chiral limit. This result suggests that at Q 2 =0 the matrix element of the flavor singlet axial current in a polarized proton state is small while the proton spin is still one-half. Modulo the QCD evolution equation, this result is in fair agreement with the recent EMC data. (orig.)

  13. Axial to transverse energy mixing dynamics in octupole-based magnetostatic antihydrogen traps

    Science.gov (United States)

    Zhong, M.; Fajans, J.; Zukor, A. F.

    2018-05-01

    The nature of the trajectories of antihydrogen atoms confined in an octupole minimum-B trap is of great importance for upcoming spectroscopy, cooling, and gravity experiments. Of particular interest is the mixing time between the axial and transverse energies for the antiatoms. Here, using computer simulations, we establish that almost all trajectories are chaotic, and then quantify the characteristic mixing time between the axial and transverse energies. We find that there are two classes of trajectories: for trajectories whose axial energy is higher than about 20% of the total energy, the axial energy substantially mixes within about 10 s, whereas for trajectories whose axial energy is lower than about 10% of the total energy, the axial energy remains nearly constant for 1000 s or longer.

  14. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  15. An axial calculation method for accurate two-dimensional PWR core simulation

    International Nuclear Information System (INIS)

    Grimm, P.

    1985-02-01

    An axial calculation method, which improves the agreement of the multiplication factors determined by two- and three-dimensional PWR neutronic calculations, is presented. The axial buckling is determined at each time point so as to reproduce the increase of the leakage due to the flattening of the axial power distribution and the effect of the axial variation of the group constants of the fuel on the reactivity is taken into account. The results of a test example show that the differences of k-eff and cycle length between two- and three-dimensional calculations, which are unsatisfactorily large if a constant buckling is used, become negligible if the results of the axial calculation are used in the two-dimensional core simulation. (Auth.)

  16. Endoscopic optical coherence tomography with a focus-adjustable probe.

    Science.gov (United States)

    Liao, Wenchao; Chen, Tianyuan; Wang, Chengming; Zhang, Wenxin; Peng, Zhangkai; Zhang, Xiao; Ai, Shengnan; Fu, Deyong; Zhou, Tieying; Xue, Ping

    2017-10-15

    We present a focus-adjustable endoscopic probe for optical coherence tomography (OCT), which is able to acquire images with different focal planes and overcome depth-of-focus limitations by image fusing. The use of a two-way shape-memory-alloy spring enables the probe to adjust working distance over 1.5 mm, providing a large scanning range with high resolution and no sensitivity loss. Equipped with a homemade hollow-core ultrasonic motor, the probe is capable of performing an unobstructed 360 deg field-of-view distal scanning. Both the axial resolution and the best lateral resolution are ∼4  μm, with a sensitivity of 100.3 dB. Spectral-domain OCT imaging of phantom and biological tissues with the probe is also demonstrated.

  17. Comparison of Accuracy of Contrast Enhanced Computed Tomography with Accuracy of Non-Contrast Magnetic Resonance Imaging in Evaluation of Local Extension of Base of Tongue Malignancies

    Directory of Open Access Journals (Sweden)

    Ketan Rathod

    2018-01-01

    Full Text Available Diagnosis of base of tongue malignancy can be obtained through clinical examination and biopsy. Magnetic Resonance Imaging (MRI and Computed Tomography (CT are used to detect its local extension, nodal spread and distant metastases. The main aim of study was to compare the accuracy of MRI and contrast enhanced CT in determining the local extent of base of tongue malignancy. Twenty five patients, biopsy proven cases of squamous cell carcinoma of base of tongue were taken. 1.5 Tesla Magnetic Resonance Unit with T2 weighted axial, coronal image; T1 weighted axial, coronal image; and STIR (Short tau inversion recovery axial and coronal images were used. 16 slice Computed Tomography unit with non-contrast and contrast enhanced images were used. Accuracy of CT to detect midline crossing: 50%; accuracy of MRI to detect midline crossing: 100%; accuracy of CT to detect anterior extension: 92%; accuracy of MRI to detect anterior extension: 100%; accuracy of CT to detect tonsillar fossa invasion: 83%; accuracy of MRI to detect tonsillar fossa invasion: 100%; accuracy of CT to detect oro pharyngeal spread: 83%; accuracy of MRI to detect oro pharyngeal spread: 100%; accuracy of CT to detect bone involvement: 20%; accuracy of MRI to detect bone involvement: 100%. MRI proved to be a better investigation than CT, in terms of evaluation of depth of invasion, presence of bony involvement, extension to opposite side, anterior half of tongue, tonsillar fossa, floor of mouth or oropharynx.

  18. The Effect of Material Property on the Critical Velocity of Randomly Excited Nonlinear Axially Travelling Functionally Graded Plates

    Directory of Open Access Journals (Sweden)

    M. Abedi

    Full Text Available Abstract In this paper, the critical axial speeds of three types of sigmoid, power law and exponential law functionally graded plates for both isotropic and orthotropic cases are obtained via a completely analytic method. The plates are subjected to lateral white noise excitation and show evidence of large deformations. Due to randomness, the conventional deterministic methods fail and a statistical approach must be selected. Here, the probability density function is evaluated analytically for prescribed plates and used to investigate the critical axial velocity of them. Specifically the effect of in-plane forces, mean value of lateral load and the material property on the critical axial speed are studied and discussed for both isotropic and orthotropic functionally graded plates. Since the governing equation is transformed to a non dimensional format, the results can be used for a wide range of plate dimensions. It is shown that the material heterogeneity palys an essential and significant role in increasing or decreasing the critical speed of both isotropic and orthotropic functionally graded plates.

  19. Axial Skeletal Scintigraphy in Cancer of the Breast

    Energy Technology Data Exchange (ETDEWEB)

    Galasko, C. S.B. [Royal Postgraduate Medical School and Hammersmith Hospital, London (United Kingdom)

    1969-05-15

    An initial study was made on eight patients shown to have osseous metastases on X-ray. Each patient was examined on two occasions after the injection of {sup 87m}Sr and {sup 18}F. Regions known to contain metastases were examined at regular intervals after each injection. The scintigrams were compared with X-ray skeletal surveys. In all patients the {sup 18}F scintigram gave better results than the {sup 87m}Sr scan. All metastases present on X-ray were detected with the gamma camera and in six patients the scintigram revealed additional lesions. The optimum times for scanning were 1 1/4-3 hours after injection of {sup 18}F and 3-4 1/2 hours after {sup 87m}Sr. Axial skeleton scintigrams using {sup 18}F and a gamma camera are now being done on: (i) patients with apparently 'early' cancer of the breast. (ii) patients who have had a mastectomy and in whom there is a suspicion but no overt evidence of metastases. (iii) patients with advanced cancer of the breast. By means of this method it is hoped: (a) to detect lesions not present on X-ray. (b) to assess progress following hormonal therapy. 'Healing' lesions tend to have a diminished uptake of the isotope, and the varying pattern may prove to be more easy to interpret than conventional X-rays. The technique of axial skeleton scanning with the gamma camera and {sup 18}F, and the results obtained in over 60 patients with cancer of the breast, are reported. (author)

  20. Mixing and axial dispersion in Taylor-Couette flow: experimental and numerical study

    International Nuclear Information System (INIS)

    Nemri, M.

    2013-01-01

    Taylor-Couette flows between two concentric cylinders have great potential applications in chemical engineering. They are particularly convenient for two-phase small scale devices enabling solvent extraction operations. An experimental device was designed with this idea in mind. It consists of two concentric cylinders with the inner one rotating and the outer one fixed. Taylor-Couette flows take place in the annular gap between them, and are known to evolve towards turbulence through a sequence of successive instabilities. Macroscopic quantities, such as axial dispersion and mixing index, are extremely sensitive to these flow structures, which may lead to flawed modelling of the coupling between hydrodynamics and mass transfer. This particular point has been studied both experimentally and numerically. The flow and mixing have been characterized by means of flow visualization and simultaneous PIV (Particle Imaging Velocimetry) and PLIF (Planar Laser Induced Fluorescence) measurements. PLIF visualizations showed clear evidences of different transport mechanisms including 'intra-vortex mixing' and 'inter-vortex mixing'. Under WVF and MWVF regimes, intra-vortex mixing is controlled by chaotic advection, due to the 3D nature of the flow, while inter-vortex transport occurs due to the presence of waves between neighboring vortices. The combination of these two mechanisms results in enhanced axial dispersion. We showed that hysteresis may occur between consecutive regimes depending on flow history and this may have a significant effect on mixing for a given Reynolds number. The axial dispersion coefficient Dx evolution along the successive flow states was investigated thanks to dye Residence Time Distribution measurements (RTD) and particle tracking (DNS). Both experimental and numerical results have confirmed the significant effect of the flow structure and history on axial dispersion. Our study confirmed that the commonly used 1-parameter chemical engineering models (e

  1. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  2. Body composition changes in females treated for breast cancer: a review of the evidence

    OpenAIRE

    Sheean, Patricia M.; Hoskins, Kent; Stolley, Melinda

    2012-01-01

    Body composition changes cannot be precisely captured using body weight or body mass index measures. Therefore, the primary purpose of this review was to characterize the patterns of body composition change in females treated for breast cancer including only studies that utilize imaging technologies to quantify adipose tissue and lean body mass (LBM). We reviewed PubMed for studies published between 1971–2012 involving females diagnosed with breast cancer where computed axial tomography (CAT)...

  3. Equation of motion for the axial gravitational superfield

    International Nuclear Information System (INIS)

    Ogievetsky, V.; Sokatchev, E.

    1980-01-01

    Transformation properties of the axial supergravitational field variants are investigated. The equation of motion for the axial gravitational superfield is derived by direct variation of the N = 1 supergravity action. The left-hand side of this equation is a component of the torsion tensor, and the right-hand side is the supercurrent. The question about the cosmological term in supergravity is discussed

  4. Development of vortex model with realistic axial velocity distribution

    International Nuclear Information System (INIS)

    Ito, Kei; Ezure, Toshiki; Ohshima, Hiroyuki

    2014-01-01

    A vortex is considered as one of significant phenomena which may cause gas entrainment (GE) and/or vortex cavitation in sodium-cooled fast reactors. In our past studies, the vortex is assumed to be approximated by the well-known Burgers vortex model. However, the Burgers vortex model has a simple but unreal assumption that the axial velocity component is horizontally constant, while in real the free surface vortex has the axial velocity distribution which shows large gradient in radial direction near the vortex center. In this study, a new vortex model with realistic axial velocity distribution is proposed. This model is derived from the steady axisymmetric Navier-Stokes equation as well as the Burgers vortex model, but the realistic axial velocity distribution in radial direction is considered, which is defined to be zero at the vortex center and to approach asymptotically to zero at infinity. As the verification, the new vortex model is applied to the evaluation of a simple vortex experiment, and shows good agreements with the experimental data in terms of the circumferential velocity distribution and the free surface shape. In addition, it is confirmed that the Burgers vortex model fails to calculate accurate velocity distribution with the assumption of uniform axial velocity. However, the calculation accuracy of the Burgers vortex model can be enhanced close to that of the new vortex model in consideration of the effective axial velocity which is calculated as the average value only in the vicinity of the vortex center. (author)

  5. Anisotropic yield surfaces in bi-axial cyclic plasticity

    International Nuclear Information System (INIS)

    Rider, R.J.; Harvey, S.J.; Breckell, T.H.

    1985-01-01

    Some aspects of the behaviour of yield surfaces and work-hardening surfaces occurring in biaxial cyclic plasticity have been studied experimentally and theoretically. The experimental work consisted of subjecting thin-walled tubular steel specimens to cyclic plastic torsion in the presence of sustained axial loads of various magnitudes. The experimental results show that considerable anisotropy is induced when the cyclic shear strains are dominant. Although the true shapes of yield and work-hardening surfaces can be very complex, a mathematical model is presented which includes both anisotropy and Bauschinger effects. The model is able to qualitatively predict the deformation patterns during a cycle of applied plastic shear strain for a range of sustained axial stresses and also indicate the material response to changes in axial stress. (orig.)

  6. Axial charge of the weak nucleon current extracted from the β decays of spin aligned 12B and 12N

    International Nuclear Information System (INIS)

    Yamaguchi, Takayuki

    1998-01-01

    The alignment correlation terms in the β-ray angular distributions of the 12 B and 12 N mirror nuclei have been precisely measured, in order to investigate the mesonic effect in the axial charge matrix element. The spin alignments were created with the spin manipulation technique in the β-NMR method, which has been improved based on the recent studies of hyperfine interactions of 12 B and 12 N in a Mg crystal. From the sum of the alignment correlation terms, the ratio of the axial charge to the Gamow-Teller term was determined to be y = 4.66 ± 0.06(stat) ± 0.13(syst). The present result gives clear evidence of the mesonic effect in the axial charge and even more shows 16 ± 6% enhancement over the full calculation which includes the meson exchange effect and the core polarization effect. A possible mass renormalization for the decaying nucleon in a finite nucleon density explains this enhancement. (author)

  7. Light-front view of the axial anomaly

    International Nuclear Information System (INIS)

    Ji, C.; Rey, S.

    1996-01-01

    Motivated by an apparent puzzle of the light-front vacua incompatible with the axial anomaly, we have considered the two-dimensional massless Schwinger model for an arbitrary interpolating angle of Hornbostel close-quote s interpolating quantization surface. By examining spectral deformation of the Dirac sea under an external electric field semiclassically, we have found that the axial anomaly is quantization angle independent. This indicates an intricate nontrivial vacuum structure present even in the light-front limit. copyright 1996 The American Physical Society

  8. Gravitational waves from the axial perturbations of hyperon stars

    International Nuclear Information System (INIS)

    Wen De-Hua; Yan Jing; Liu Xue-Mei

    2012-01-01

    The eigen-frequencies of the axial w-mode oscillations of hyperon stars are examined. It is shown that as the appearance of hyperons softens the equation of state of the super-density matter, the frequency of gravitational waves from the axial w-mode of hyperon star becomes smaller than that of a traditional neutron star at the same stellar mass. Moreover, the eigenfrequencies of hyperon stars also have scaling universality. It is shown that the EURO third-generation gravitational-wave detector has the potential to detect the gravitational-wave signal emitted from the axial w-mode oscillations of a hyperon star. (general)

  9. Axial injection in Orsay superconducting cyclotron

    International Nuclear Information System (INIS)

    Depauw, J.; Kugler, M.F.; Legoff, A.; Potier, J.C.; Richomme, A.; Skowron, R.; Mandrillon, P.; Schapira, J.P.

    1983-01-01

    The compact superconducting cyclotron currently planned at IPN at Orsay is designed for light ion acceleration together with heavy ion acceleration. From the beginning, for this reason, a central geometry able to receive an inflector (to 90deg C) allowing the axial injection of low energy ion beams given by an outer source. The present study is aimed at showing the technical feasibility of theoretical results obtained on axial injection. First experimental study has been made of spatial repartition in three dimensions of electric potential developed by a central geometry of 3 electrodes. Then, the electric study of an electrostatic mirror has been made [fr

  10. Simultaneous /sup 201/Tl//sup 99m/Tc seven-pinhole tomography in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T; Schuemichen, C; Fischer, R; Strauss, E; Hoffmann, G

    1986-06-01

    Combined infarction scintigraphy with /sup 201/Tl-chloride and /sup 99m/Tc-pyrophosphate (PPi) by simultaneous seven-pinhole tomography was investigated with a phantom as well as in patients. No artificial defects occurred when the collimator was centered correctly in axial position, but a very high standard of image uniformity and linearity of the gamma camera was required. Artefacts by overlying activity from the skeleton or cardiac blood pool were not observed. All 11 controls showed normal results. Despite a poor depth resolution due to limitations of the system even small areas of partially damaged myocardium could be recognized and correlated three-dimensionally. Of 24 patients with proven myocardial infarction, in 16 both a positive (/sup 99m/Tc-PPi) and a negative (/sup 201/Tl) image was obtained in congruence with the necrosis. 8 patients (33%) showed discordant results providing however additional information on the nature and extent of the necrosis. 4 out of 6 non-transmural infarctions seen by tomography had been suspected clinically.

  11. Evaluation of Optic Canal and Surrounding Structures Using Cone Beam Computed Tomography: Considerations for Maxillofacial Surgery.

    Science.gov (United States)

    Sinanoglu, Alper; Orhan, Kaan; Kursun, Sebnem; Inceoglu, Beste; Oztas, Bengi

    2016-07-01

    The optic canal connects the anterior cranial fossa and the orbit and maintains the optic nerve and the ophthalmic artery. Within the extent of the surgical approach of the region, risk of iatrogenic injury of the neural and vascular structures increases. The aim of this retrospective morphometric study is to investigate the radiological anatomy of orbita, optic canal, and its surrounding using cone beam computed tomography (CBCT) scans in a group of Turkish population.Cone beam computed tomography images of a total of 182 patients were evaluated by 2 observers. Anatomical parameters regarding optic canal and orbita were measured for all patients from axial, sagittal, and three-dimensional reconstructed images. To assess intraobserver reliability, the Wilcoxon matched-pairs test was used. Pearson χ test and Student t test were performed for statistical analysis of differences, sex, localization, and measurements (P  0.05). The orbita width and height were larger for the males than females (P  0.05). Examination CBCT scans revealed that the shape of the optic canal was 70% funnel and 28% Hourglass shape, 2% amorph type round.These results provide detailed knowledge of the anatomical characteristics in the orbital area which may be of assistance for surgeons preoperatively. Cone beam computed tomography scans can be an alternative modality for multislice computed tomography with submillimeter resolution and lower dose in preoperative imaging of the orbit.

  12. Bessel beam CARS of axially structured samples

    Science.gov (United States)

    Heuke, Sandro; Zheng, Juanjuan; Akimov, Denis; Heintzmann, Rainer; Schmitt, Michael; Popp, Jürgen

    2015-06-01

    We report about a Bessel beam CARS approach for axial profiling of multi-layer structures. This study presents an experimental implementation for the generation of CARS by Bessel beam excitation using only passive optical elements. Furthermore, an analytical expression is provided describing the generated anti-Stokes field by a homogeneous sample. Based on the concept of coherent transfer functions, the underling resolving power of axially structured geometries is investigated. It is found that through the non-linearity of the CARS process in combination with the folded illumination geometry continuous phase-matching is achieved starting from homogeneous samples up to spatial sample frequencies at twice of the pumping electric field wave. The experimental and analytical findings are modeled by the implementation of the Debye Integral and scalar Green function approach. Finally, the goal of reconstructing an axially layered sample is demonstrated on the basis of the numerically simulated modulus and phase of the anti-Stokes far-field radiation pattern.

  13. Uniform Decay for Solutions of an Axially Moving Viscoelastic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kelleche, Abdelkarim, E-mail: kellecheabdelkarim@gmail.com [Université des Sciences et de la Technologie Houari Boumediene, Faculté des Mathématiques (Algeria); Tatar, Nasser-eddine, E-mail: tatarn@Kfupm.edu.sa [King Fahd University of Petroleum and Minerals, Department of Mathematics and Statistics (Saudi Arabia)

    2017-06-15

    The paper deals with an axially moving viscoelastic structure modeled as an Euler–Bernoulli beam. The aim is to suppress the transversal displacement (transversal vibrations) that occur during the axial motion of the beam. It is assumed that the beam is moving with a constant axial speed and it is subject to a nonlinear force at the right boundary. We prove that when the axial speed of the beam is smaller than a critical value, the dissipation produced by the viscoelastic material is sufficient to suppress the transversal vibrations. It is shown that the rate of decay of the energy depends on the kernel which arise in the viscoelastic term. We consider a general kernel and notice that solutions cannot decay faster than the kernel.

  14. Atlanto-axial Subluxation in rheumatoid arthritis: description of a case

    International Nuclear Information System (INIS)

    Medina, Yimy F; Martinez V, Jose B; Restrepo, Jose Felix; Rondon H, Federico; Iglesias G, Antonio

    2004-01-01

    The damage of the spine by rheumatoid arthritis is multiple and a variety of affectations have been described at cervical level, being the anterior atlanto-axial subluxation and vertical subluxation the more common. However the posterior atlanto-axial subluxation has been rarely described. In this paper, we describe the case of a patient with posterior atlanto-axial subluxaction in addition to its infrequent manifestation of alteration of the lower cranial nerves as a manifestation of myelopathy

  15. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  16. Analysis of axial compressive loaded beam under random support excitations

    Science.gov (United States)

    Xiao, Wensheng; Wang, Fengde; Liu, Jian

    2017-12-01

    An analytical procedure to investigate the response spectrum of a uniform Bernoulli-Euler beam with axial compressive load subjected to random support excitations is implemented based on the Mindlin-Goodman method and the mode superposition method in the frequency domain. The random response spectrum of the simply supported beam subjected to white noise excitation and to Pierson-Moskowitz spectrum excitation is investigated, and the characteristics of the response spectrum are further explored. Moreover, the effect of axial compressive load is studied and a method to determine the axial load is proposed. The research results show that the response spectrum mainly consists of the beam's additional displacement response spectrum when the excitation is white noise; however, the quasi-static displacement response spectrum is the main component when the excitation is the Pierson-Moskowitz spectrum. Under white noise excitation, the amplitude of the power spectral density function decreased as the axial compressive load increased, while the frequency band of the vibration response spectrum increased with the increase of axial compressive load.

  17. SCLERAL AND CHOROIDAL THICKNESS IN SECONDARY HIGH AXIAL MYOPIA.

    Science.gov (United States)

    Shen, Ling; You, Qi Sheng; Xu, Xiaolin; Gao, Fei; Zhang, Zhibao; Li, Bin; Jonas, Jost B

    2016-08-01

    To assess differences in scleral and choroidal thickness between eyes with secondary high axial myopia caused by congenital glaucoma, eyes with primary high axial myopia, and nonhighly myopic eyes. The study consisted of 301 Chinese individuals with a mean age of 23.9 ± 22.6 years and mean axial length of 24.8 ± 4.2 mm. It included the "secondary highly myopic group" (SHMG) because of congenital glaucoma (n = 20 eyes; axial length >26.0 mm), the "primary highly myopic group" (PHMG) (n = 73; axial length >26.0 mm), and the remaining nonhighly myopic group (NHMG). The secondary highly myopic group versus the primary highly myopic group had significantly thinner sclera in the pars plana region (343 ± 71 μm versus 398 ± 83 μm; P = 0.006), whereas scleral thickness in other regions did not differ significantly between both highly myopic groups and was significantly thinner in both highly myopic groups than in the NHMG. Mean total scleral volume did not differ significantly (P > 0.20) between any group (SHMG: 659 ± 106 μm; PHMG: 667 ± 128 μm; NHMG: 626 ± 135 μm). Choroidal thickness was significantly thinner in both highly myopic groups than in the NHMG, with no significant differences between both highly myopic groups. Choroidal volume did not differ significantly (P > 0.40) between any of the groups (SHMG: 43 ± 12 μm; PHMG: 43 ± 13 μm; NHMG: 46 ± 17 μm). In secondary high axial myopia, the sclera gets thinner anterior and posterior to the equator; whereas in primary high axial myopia, scleral thinning is predominantly found posterior to the equator. Because volume of sclera and choroid did not differ between any group, scleral and choroidal thinning in myopia may be due to a rearrangement of tissue and not due to the new formation of tissue.

  18. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  19. Two dimensional vibrations of the guinea pig apex organ of Corti measured in vivo using phase sensitive Fourier domain optical coherence tomography

    Science.gov (United States)

    Ramamoorthy, Sripriya; Zhang, Yuan; Petrie, Tracy; Fridberger, Anders; Ren, Tianying; Wang, Ruikang; Jacques, Steven L.; Nuttall, Alfred L.

    2015-02-01

    In this study, we measure the in vivo apical-turn vibrations of the guinea pig organ of Corti in both axial and radial directions using phase-sensitive Fourier domain optical coherence tomography. The apical turn in guinea pig cochlea has best frequencies around 100 - 500 Hz which are relevant for human speech. Prior measurements of vibrations in the guinea pig apex involved opening the otic capsule, which has been questioned on the basis of the resulting changes to cochlear hydrodynamics. Here this limitation is overcome by measuring the vibrations through bone without opening the otic capsule. Furthermore, we have significantly reduced the surgery needed to access the guinea pig apex in the axial direction by introducing a miniature mirror inside the bulla. The method and preliminary data are discussed in this article.

  20. Study of localized corrosion in AA2024 aluminium alloy using electron tomography

    International Nuclear Information System (INIS)

    Zhou, X.; Luo, C.; Hashimoto, T.; Hughes, A.E.; Thompson, G.E.

    2012-01-01

    Highlights: ► SEM tomography of localized corrosion has been achieved. ► Nanotomography provides evidence that links microstructure and corrosion propagation path. ► IGC stemmed from localized corrosion associated with buried clusters of intermetallics. ► IGC started beneath the alloy surface and may emerge on the alloy surface. - Abstract: SEM based tomography of localized corrosion has been achieved using selective detection of backscattered electrons. The high resolution tomography provides direct evidence that links the surface appearance of corroded alloy, the alloy microstructure and the corrosion propagation path. Stable localized corrosion of AA2024-T351 aluminium alloy was initiated at locations where large clusters of S phase particles were buried beneath the surface. Propagating away from the initiation sites, corrosion developed preferentially along the grain boundary network. The grain boundary attack started beneath the alloy surface, proceeded along preferred grain boundaries and may emerge at the alloy surface.

  1. Plasma sheath axial phase dynamics in coaxial device

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, H.M. (Plasma Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)); Masoud, M.M. (Plasma Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt))

    1994-10-01

    The study of the plasma sheath dynamics in the axial phase has been carried out in a 3 kJ coaxial system of Mather type for two different inner electrode (IE) lengths, 20 cm and 31.5 cm. For both lengths, measurements showed that the plasma sheath is splitted into two layers at the breech, which is referred to as a shock front and its magnetic piston. It has been found that the two layers of the plasma current sheath rotate around the inner electrode. At the muzzle the back layer reverse its rotation direction due to the magnetic field structure of the system. Results showed that the axial velocity of the first layer is greater than the second one all over the axial phase within the range between 1.4 and 1.7. (orig.).

  2. Plasma sheath axial phase dynamics in coaxial device

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.

    1994-01-01

    The study of the plasma sheath dynamics in the axial phase has been carried out in a 3 kJ coaxial system of Mather type for two different inner electrode (IE) lengths, 20 cm and 31.5 cm. For both lengths, measurements showed that the plasma sheath is splitted into two layers at the breech, which is referred to as a shock front and its magnetic piston. It has been found that the two layers of the plasma current sheath rotate around the inner electrode. At the muzzle the back layer reverse its rotation direction due to the magnetic field structure of the system. Results showed that the axial velocity of the first layer is greater than the second one all over the axial phase within the range between 1.4 and 1.7. (orig.)

  3. Tumor-Induced Osteomalacia Caused by Primary Fibroblast Growth Factor 23 Secreting Neoplasm in Axial Skeleton: A Case Report

    Directory of Open Access Journals (Sweden)

    Gunjan Y. Gandhi

    2012-01-01

    Full Text Available We report the case of a 66-year-old woman with tumor-induced osteomalacia (TIO caused by fibroblast growth factor 23 (FGF-23 secreting mesenchymal tumor localized in a lumbar vertebra and review other cases localized to the axial skeleton. She presented with nontraumatic low back pain and spontaneous bilateral femur fractures. Laboratory testing was remarkable for low serum phosphorus, phosphaturia, and significantly elevated serum FGF-23 level. Magnetic resonance imaging (MRI of the lumbar spine showed a focal lesion in the L-4 vertebra which was hypermetabolic on positron emission tomography (PET scan. A computed tomography (CT guided needle biopsy showed a low grade spindle cell neoplasm with positive FGF-23 mRNA expression by reverse transcriptase polymerase chain reaction (RT-PCR, confirming the diagnosis of a phosphaturic mesenchymal tumor mixed connective tissue variant (PMTMCT. The patient elected to have surgery involving anterior resection of L-4 vertebra with subsequent normalization of serum phosphorus. Including the present case, we identified 12 cases of neoplasms localized to spine causing TIO. To our knowledge, this paper represents the first documented case of lumbar vertebra PMT causing TIO. TIO is a rare metabolic bone disorder that carries a favorable prognosis. When a lesion is identifiable, surgical intervention is typically curative.

  4. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  5. Generation of parasitic axial flow by drift wave turbulence with broken symmetry: Theory and experiment

    Science.gov (United States)

    Hong, R.; Li, J. C.; Hajjar, R.; Chakraborty Thakur, S.; Diamond, P. H.; Tynan, G. R.

    2018-05-01

    Detailed measurements of intrinsic axial flow generation parallel to the magnetic field in the controlled shear decorrelation experiment linear plasma device with no axial momentum input are presented and compared to theory. The results show a causal link from the density gradient to drift-wave turbulence with broken spectral symmetry and development of the axial mean parallel flow. As the density gradient steepens, the axial and azimuthal Reynolds stresses increase and radially sheared azimuthal and axial mean flows develop. A turbulent axial momentum balance analysis shows that the axial Reynolds stress drives the radially sheared axial mean flow. The turbulent drive (Reynolds power) for the azimuthal flow is an order of magnitude greater than that for axial flow, suggesting that the turbulence fluctuation levels are set by azimuthal flow shear regulation. The direct energy exchange between axial and azimuthal mean flows is shown to be insignificant. Therefore, the axial flow is parasitic to the turbulence-zonal flow system and is driven primarily by the axial turbulent stress generated by that system. The non-diffusive, residual part of the axial Reynolds stress is found to be proportional to the density gradient and is formed due to dynamical asymmetry in the drift-wave turbulence.

  6. Manufacture of axially insulated large-area diodes

    International Nuclear Information System (INIS)

    Ma Weiyi; Zhou Kungang; Wang Youtian; Zhang Dong; Shan Yusheng; Wang Naiyan

    1999-01-01

    The author describes the design and construction of the axially insulated large-area diodes used in the 'Heaven-1'. The four axially insulated large-area diodes are connected to the 10 ohm pulse transmission lines via the vacuum feed through tubes. The experimental results with the diodes are given. The diodes can steadily work at the voltage of 650 kV, and the diode current density is about 80 A per cm 2 with a pulse width of 220 ns. The electron beams with a total energy of 25 kJ are obtained

  7. Axial nucleon form factors from lattice QCD

    International Nuclear Information System (INIS)

    Alexandrou, C.; Brinet, M.; Carbonell, J.; Harraud, P. A.; Papinutto, M.; Constantinou, M.; Guichon, P.; Jansen, K.; Korzec, T.

    2011-01-01

    We present results on the nucleon axial form factors within lattice QCD using two flavors of degenerate twisted mass fermions. Volume effects are examined using simulations at two volumes of spatial length L=2.1 fm and L=2.8 fm. Cut-off effects are investigated using three different values of the lattice spacings, namely a=0.089 fm, a=0.070 fm and a=0.056 fm. The nucleon axial charge is obtained in the continuum limit and chirally extrapolated to the physical pion mass enabling comparison with experiment.

  8. Topological invariants and the dynamics of an axial vector torsion field

    International Nuclear Information System (INIS)

    Drechsler, W.

    1983-01-01

    A generalized throry of gravitation is discussed which is based on a Riemann-Cartan space-time, U 4 , with an axial vector torsion field. Besides Einstein's equations determining the metric of the U 4 a system of nonlinear field equations is established coupling an axial vector source current to the axial vector torsion field. The properties of the solutions of these equations are discussed assuming a London-type condition relating the axial current and torsion field. To characterize the solutions use is made of the Euler and Pontrjagin forms and the associated quadratic curvature invariants for the U 4 space-time. It is found that there exists for a Riemann-Cartan space-time a relation between the zeros of the axial vector torsion field and the singularities of the Pontrjagin invariant, which is analogous to the well-known Hopf relation between the zeros of vector fields and the Euler characteristic. (author)

  9. Lateral atlanto-axial joint block for cervical headache

    Directory of Open Access Journals (Sweden)

    Shantanu P Mallick

    2013-01-01

    Full Text Available The patient is a 32-year-old car mechanic, having chronic headache for three years affecting the left upper lateral part of the neck, suboccipital region, and scalp (VAS: 8/10, having a history of whiplash injury from a car accident three years ago, with a deep cut injury on the scalp. He was complaining of neck stiffness and pain during all neck movements and a burning pain in the entire left side of the neck and scalp. He was treated, using conservative methods, by Orthopedists, Neurologists, as well as Psychiatrists, and all investigations including computed tomography (CT of the brain, X-ray cervical spine, and all related blood reports were within normal limits. He was sent to the Pain Clinic for further assessment. Suspecting sympathetic mediated pain on the left side and upper cervical facet pain, he was given a diagnostic Stellate Ganglion Block, a Third Occipital Nerve block, and a fourth cervical medial branch block (MBB, which gave him good relief; by this the visual analog scale (VAS score reduced to 3/10. Yet, he was complaining of pain on a focal area on the left upper cervical spine corresponding to the C1-2 joint with lateral rotation on the left side. Subsequently it was decided that a diagnostic Atlanto-axial joint block under fluoroscopy would be carried out. This gave him very good relief from the cervicogenic headache.

  10. Axial holdup in pulsed perforated-plate column of pulser feeder type, (2)

    International Nuclear Information System (INIS)

    Ikeda, Hidematsu; Suzuki, Atsuyuki; Kiyose, Ryohei.

    1987-01-01

    In mathematical models for a pulsed perforated-plate column, the dispersed phase holdup has been considered to be uniform throughout the length of the column, but fairly recently it is treated as being nonuniform. In the previous paper, the axial holdup data were obtained in the dispersed aqueous and the dispersed organic modes. Experimental results showed that the axial holdup data become nonuniform throughout the column. It was also found that both of the plate type and the operation mode affected the axial holdup distribution. The present work is an attempt to formulate the axial holdup by means of a heuristic selforganization method that provides a nonlinear prediction model of complex system, since the holdup data did not directly show so significant trend as to formulate the axial holdup. The Group Method of Data Handling (GMDH) is used for this purpose. The GMDH can be used for selection and synthesis of input variables concerned with the axial holdup for the pulsed perforated-plate column. The axial holdup data have been successfully correlated and the identification models could be useful in discussing mathematical models. (author)

  11. Evaluation of efficiency of axial profiling in WWER-440 fuel assemblies

    International Nuclear Information System (INIS)

    Ananjev, Yu. A.; Kurakin, K. Yu.; Artemov, V.G.; Ivanov, A.S.

    2005-01-01

    The present report deals with consideration of fuel enrichment axial profiling in WWER-440 assemblies. The study is performed on improving the effectiveness of fuel utilization using the example of implementing the axial profiling in the assemblies of the second generation. For simulation of fuel loadings the computer code package SAPFIR 9 5 and RC is used that allows for correct consideration of specific features of assemblies design changes. The methodical approach to assessment of effectiveness of implementing the axial profiling is considered with the use of capabilities of the mentioned code package. In conclusion the recommendations are given on using the fuel enrichment axial profiling in WWER-440 assemblies (Authors)

  12. Dermal reflectivity determined by optical coherence tomography is an indicator of epidermal hyperplasia and dermal edema within inflamed skin

    Science.gov (United States)

    Phillips, Kevin G.; Wang, Yun; Levitz, David; Choudhury, Niloy; Swanzey, Emily; Lagowski, James; Kulesz-Martin, Molly; Jacques, Steven L.

    2011-04-01

    Psoriasis is a common inflammatory skin disease resulting from genetic and environmental alterations of cutaneous immune responses. While numerous therapeutic targets involved in the immunopathogenesis of psoriasis have been identified, the in vivo dynamics of inflammation in psoriasis remain unclear. We undertook in vivo time course focus-tracked optical coherence tomography (OCT) imaging to noninvasively document cutaneous alterations in mouse skin treated topically with Imiquimod (IMQ), an established model of a psoriasis-like disease. Quantitative appraisal of dermal architectural changes was achieved through a two parameter fit of OCT axial scans in the dermis of the form A(x, y, z) = ρ(x, y)exp [ - μ(x, y)z]. Ensemble averaging over 2000 axial scans per mouse in each treatment arm revealed no significant changes in the average dermal attenuation rate, , however the average local dermal reflectivity , decreased significantly following 1, 3, and 6 days of IMQ treatment (p humans.

  13. Computed tomography of cystic nerve root sleeve dilatation.

    Science.gov (United States)

    Neave, V C; Wycoff, R R

    1983-10-01

    A case of cystic nerve root sleeve dilatation in the lumbar area associated with a chronic back pain syndrome is presented. Prominent computed tomography (CT) findings include: (a) rounded masses in the region of the foramina isodense with cerebrospinal fluid in the subarachnoid space; (b) associated asymmetry of epidural fat distribution; (c) enlargement of the neural foramina in axial sections with scalloped erosion of the adjacent posteriolateral vertebral body, pedicle, and pedicular-laminar junction with preservation of cortex and without bony sclerosis or infiltrative appearance; (d) prominent or ectatic dural sac with lack of usual epidural landmarks between the sac and vertebral body; and (e) multilevel abnormalities throughout the entire lumbar region. Myelographic and CT correlations are demonstrated with a review of the literature. A discussion of the various cystic abnormalities involving nerve root sheaths is undertaken in an attempt to clarify the confusing nomenclature applied to nerve root sleeve pathology.

  14. Precautions against axial fan stall in reactor building to Tianwan NPP

    International Nuclear Information System (INIS)

    Liu Chunlong; Pei Junmin

    2011-01-01

    The paper introduces the mechanism and harm of rotating stall of axial fans, analyzes the necessity for prevention against axial fan stall in reactor building of Tianwan NPP, introduces the precautions, and then makes an assessment on anti-stall effect of flow separators. It can provide reference for model-selection or reconstruction of similar fans in power stations, and for operation and maintenance of axial fans. (authors)

  15. Wood anatomical correlates with theoretical conductivity and wood density across China: evolutionary evidence of the functional differentiation of axial and radial parenchyma.

    Science.gov (United States)

    Zheng, Jingming; Martínez-Cabrera, Hugo I

    2013-09-01

    In recent years considerable effort has focused on linking wood anatomy and key ecological traits. Studies analysing large databases have described how these ecological traits vary as a function of wood anatomical traits related to conduction and support, but have not considered how these functions interact with cells involved in storage of water and carbohydrates (i.e. parenchyma cells). We analyzed, in a phylogenetic context, the functional relationship between cell types performing each of the three xylem functions (conduction, support and storage) and wood density and theoretical conductivity using a sample of approx. 800 tree species from China. Axial parenchyma and rays had distinct evolutionary correlation patterns. An evolutionary link was found between high conduction capacity and larger amounts of axial parenchyma that is probably related to water storage capacity and embolism repair, while larger amounts of ray tissue have evolved with increased mechanical support and reduced hydraulic capacity. In a phylogenetic principal component analysis this association of axial parenchyma with increased conduction capacity and rays with wood density represented orthogonal axes of variation. In multivariate space, however, the proportion of rays might be positively associated with conductance and negatively with wood density, indicating flexibility in these axes in species with wide rays. The findings suggest that parenchyma types may differ in function. The functional axes represented by different cell types were conserved across lineages, suggesting a significant role in the ecological strategies of the angiosperms.

  16. Dynamic control of knee axial deformities

    Directory of Open Access Journals (Sweden)

    E. E. Malyshev

    2013-01-01

    Full Text Available The authors have evaluated the clinical examination of the patients with axial malalignments in the knee by the original method and device which was named varovalgometer. The measurements were conducted by tension of the cord through the spina iliaca anterior superior and the middle of the lower pole of patella. The deviation of the center of the ankle estimated by metal ruler which was positioned perpendicular to the lower leg axis on the level of the ankle joint line. The results of comparison of our method and computer navigation in 53 patients during the TKA show no statistically significant varieties but they differ by average 5° of valgus in clinical examination in comparison with mechanical axis which was identified by computer navigation. The dynamic control of axial malalignment can be used in clinical practice for estimation of the results of treatment of pathology with axial deformities in the knee; for the control of reduction and secondary displacement of the fractures around the knee; for assessment of instability; in planning of correctional osteotomies and intraoperative control of deformity correction; for estimation of Q angle in subluxation and recurrent dislocation of patella; in planning of TKA; during the growth of child it allows to assess the progression of deformity.

  17. Analysis of the axial filaments of Treponema hyodysenteriae by SDS-PAGE and immunoblotting.

    Science.gov (United States)

    Kent, K A; Sellwood, R; Lemcke, R M; Burrows, M R; Lysons, R J

    1989-06-01

    Purified axial filaments from eight serotypes of Treponema hyodysenteriae and two non-pathogenic intestinal spirochaetes were characterized by SDS-PAGE and Western blotting. Axial filaments of all ten strains had similar SDS-PAGE profiles; five major axial filament polypeptides were identified, with molecular masses of 43.8, 38, 34.8, 32.8 and 29.4 kDa. Hyperimmune gnotobiotic pig serum raised against purified axial filaments of strain P18A (serotype 4) cross-reacted with all other serotypes and with the non-pathogens, and convalescent serum taken from a pig with persistent swine dysentery also showed a strong response to the axial filament polypeptides. Hyperimmune gnotobiotic pig serum raised against axial filaments failed to agglutinate viable organisms and did not inhibit growth in vitro. Hence, the axial filaments of T. hyodysenteriae have been identified as major immunodominant antigens, although the role that antibodies to these antigens play in protection has yet to be established.

  18. Precision resection of intra-axial CNS lesions by CT-based stereotactic craniotomy and computer monitored CO2 laser

    International Nuclear Information System (INIS)

    Kelly, P.J.; Kall, B.; Goerss, S.; Alker, G.J. Jr.

    1983-01-01

    This report describes an open stereotactic technique by which a tumour volume reconstructed in stereotactic space from CT data is removed by stereotactic CO 2 laser vaporization. The position of the laser beam in relation to the tumour outlines is monitored by computer and displayed to the surgeon on a graphics display terminal in the operating room. Twenty-six (26) of these procedures have been performed on twenty-four (24) patients with deep-seated intra-axial neoplasms (23) and arteriovenous malformation. Post-operative CT scanning revealed no evidence of contrast enhancing lesions in nineteen (19) patients while a small amount of residual tumour was noted in five (5) patients post-operatively. This method has proven itself valuable for maintaining three-dimensional surgical orientation for the resection of intra-axial neoplasms from neurologically important areas. (Author)

  19. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  20. Bruch´s membrane thickness in relationship to axial length.

    Directory of Open Access Journals (Sweden)

    Hai Xia Bai

    Full Text Available To assess a potential role of Bruch´s membrane (BM in the biomechanics of the eye, we measured its thickness and the density of retinal pigment epithelium (RPE cells in various ocular regions in eyes of varying axial length.Human globes, enucleated because of an ocular tumor or end-stage glaucoma were prepared for histological examination. Using light microscopy, the histological slides were histomorphometrically examined applying a digitized image analysis system.The study included 104 eyes with a mean axial length of 27.9±3.2 mm (range:22.6mm-36.5mm. In eyes without congenital glaucoma, BM was significantly thickest (P<0.001 at the ora serrata, followed by the posterior pole, the midpoint between equator and posterior pole (MBEPP, and finally the equator. BM thickness was not significantly correlated with axial length (ora serrata: P = 0.93; equator:P = 0.31; MBEPP:P = 0.15; posterior pole:P = 0.35. RPE cell density in the pre-equatorial region (P = 0.02; regression coefficient r = -0.24 and in the retro-equatorial region (P = 0.03; r = -0.22 decreased with longer axial length, while RPE cell density at the ora serrata (P = 0.35, the MBEPP (P = 0.06; r = -0.19 and the posterior pole (P = 0.38 was not significantly correlated with axial length. Highly myopic eyes with congenital glaucoma showed a tendency towards lower BM thickness and lower RPE cell density at all locations.BM thickness, in contrast to scleral and choroidal thickness, was independent of axial length in eyes without congenital glaucoma. In association with an axial elongation associated decrease in the RPE cell density in the midperiphery, the findings support the notion of a biomechanical role BM may play in the process of emmetropization/myopization.

  1. Investigation of axial power gradients near a control rod tip

    International Nuclear Information System (INIS)

    Loberg, John; Osterlund, Michael; Bejmer, Klaes-Hakan; Blomgren, Jan; Kierkegaard, Jesper

    2011-01-01

    Highlights: → Pin power gradients near BWR control rod tips have been investigated. → A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. → Small nodes increases pin power gradients; standard nodes underestimates gradients. → The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, ∼15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  2. Nuclear chiral axial currents and applications to few-nucleon systems

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, Alessandro [Old Dominion Univ., Norfolk, VA (United States)

    2017-08-01

    This Thesis is divided into three main parts. The first part discusses basic aspects of chiral effective field theory and the formalism, based on time ordered perturbation theory, used to to derive the nuclear potentials and currents from the chiral Lagrangians. The second part deals with the actual derivation, up to one loop, of the two-nucleon potential and one- and two-nucleon weak axial charge and current. In both derivations ultraviolet divergences generated by loop corrections are isolated using dimensional regularization. The resulting axial current is finite and conserved in the chiral limit, while the axial charge requires renormalization. A complete set of contact terms for the axial charge up to the relevant order in the power counting is constructed. The third part of this Thesis discusses two applications: (i) the calculation of the Gamow-Teller matrix element of tritium, used to constrain the single low-energy constant entering the axial current; (ii) the calculation of neutrino-deuteron inclusive cross sections at low energies. These results have confirmed previous predictions obtained in phenomenological approaches. These latter studies have played an important role in the analysis and interpretation of experiments at the Sudbury Neutrino Observatory.

  3. Reconstruction of core axial power shapes using the alternating conditional expectation algorithm

    International Nuclear Information System (INIS)

    Lee, Eun Ki; Kim, Yong Hee; Cha, Kune Ho; Park, Moon Ghu

    1999-01-01

    We have introduced the alternating conditional expectation (ACE) algorithm in reconstructing 20-node axial core power shapes from five-level in-core detector powers. The core design code, Reactor Operation and Control Simulation (ROCS), calculates 3-dimensional power distributions for various core states, and the reference core-averaged axial power shapes and corresponding simulated detector powers are utilized to synthesize the axial power shape. By using the ACE algorithm, the optimal relationship between a dependent variable, the plane power, and independent variables, five detector powers, is determined without any preprocessing. A total of ∼3490 data sets per each cycle of YongGwang Nuclear (YGN) power plant units 3 and 4 is used for the regression. Continuous analytic function corresponding to each optimal transformation is calculated by simple regression model. The reconstructed axial power shapes of ∼21,200 cases are compared to the original ROCS axial power shapes. Also, to test the validity and accuracy of the new method, its performance is compared with that of the Fourier fitting method (FFM), a typical method of the deterministic approach. For a total of 21,204 data cases, the averages of root mean square (rms) error, axial peak error (ΔF z ), and axial shape index error (ΔASI) of new method are calculated as 0.81%, 0.51% and 0.00204, while those of FFM are 2.29%, 2.37% and 0.00264, respectively. We also evaluated the wide range of axial power profiles from the xenon-oscillation. The results show that the newly developed method is far superior to FFM; average rms and axial peak error are just ∼35 and ∼20% of those of FFM, respectively

  4. What changed during the axial age: Cognitive styles or reward systems?

    Science.gov (United States)

    Baumard, Nicolas; Hyafil, Alexandre; Boyer, Pascal

    2015-01-01

    The ‘Axial Age’ (500–300 BCE) refers to the period during which most of the main religious and spiritual traditions emerged in Eurasian societies. Although the Axial Age has recently been the focus of increasing interest,1-5 its existence is still very much in dispute. The main reason for questioning the existence of the Axial Age is that its nature, as well as its spatial and temporal boundaries, remain very much unclear. The standard approach to the Axial Age defines it as a change of cognitive style, from a narrative and analogical style to a more analytical and reflective style, probably due to the increasing use of external memory tools. Our recent research suggests an alternative hypothesis, namely a change in reward orientation, from a short-term materialistic orientation to a long-term spiritual one.6 Here, we briefly discuss these 2 alternative definitions of the Axial Age. PMID:27066164

  5. Axial gravity, massless fermions and trace anomalies

    International Nuclear Information System (INIS)

    Bonora, L.; Cvitan, M.; Giaccari, S.; Stemberga, T.; Prester, P.D.; Pereira, A.D.; UFF-Univ. Federal Fluminense, Niteroi

    2017-01-01

    This article deals with two main topics. One is odd parity trace anomalies in Weyl fermion theories in a 4d curved background, the second is the introduction of axial gravity. The motivation for reconsidering the former is to clarify the theoretical background underlying the approach and complete the calculation of the anomaly. The reference is in particular to the difference between Weyl and massless Majorana fermions and to the possible contributions from tadpole and seagull terms in the Feynman diagram approach. A first, basic, result of this paper is that a more thorough treatment, taking account of such additional terms and using dimensional regularization, confirms the earlier result. The introduction of an axial symmetric tensor besides the usual gravitational metric is instrumental to a different derivation of the same result using Dirac fermions, which are coupled not only to the usual metric but also to the additional axial tensor. The action of Majorana and Weyl fermions can be obtained in two different limits of such a general configuration. The results obtained in this way confirm the previously obtained ones. (orig.)

  6. Axial gravity, massless fermions and trace anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Bonora, L. [International School for Advanced Studies (SISSA), Trieste (Italy); KEK, Tsukuba (Japan). KEK Theory Center; INFN, Sezione di Trieste (Italy); Cvitan, M.; Giaccari, S.; Stemberga, T. [Zagreb Univ. (Croatia). Dept. of Physics; Prester, P.D. [Rijeka Univ. (Croatia). Dept. of Physics; Pereira, A.D. [UERJ-Univ. Estadual do Rio de Janeiro (Brazil). Dept. de Fisica Teorica; UFF-Univ. Federal Fluminense, Niteroi (Brazil). Inst. de Fisica

    2017-08-15

    This article deals with two main topics. One is odd parity trace anomalies in Weyl fermion theories in a 4d curved background, the second is the introduction of axial gravity. The motivation for reconsidering the former is to clarify the theoretical background underlying the approach and complete the calculation of the anomaly. The reference is in particular to the difference between Weyl and massless Majorana fermions and to the possible contributions from tadpole and seagull terms in the Feynman diagram approach. A first, basic, result of this paper is that a more thorough treatment, taking account of such additional terms and using dimensional regularization, confirms the earlier result. The introduction of an axial symmetric tensor besides the usual gravitational metric is instrumental to a different derivation of the same result using Dirac fermions, which are coupled not only to the usual metric but also to the additional axial tensor. The action of Majorana and Weyl fermions can be obtained in two different limits of such a general configuration. The results obtained in this way confirm the previously obtained ones. (orig.)

  7. On the problem of axial anomaly in supersymmetric gauge theories

    International Nuclear Information System (INIS)

    Kazakov, D.I.

    1984-01-01

    The explicit relation is found between the axial current obeying the Adler-Bardeen theorem and the supersymmetric one belonging to a supermultiplet. It is shown that the axial and superconformal anomalies are consistent in all orders of perturbation theory

  8. Metamorphosis of helical magnetorotational instability in the presence axial electric current

    OpenAIRE

    Priede, Jānis

    2014-01-01

    This paper presents numerical linear stability analysis of a cylindrical Taylor-Couette flow of liquid metal carrying axial electric current in a generally helical external magnetic field. Axially symmetric disturbances are considered in the inductionless approximation corresponding to zero magnetic Prandtl number. Axial symmetry allows us to reveal an entirely new electromagnetic instability. First, we show that the electric current passing through the liquid can extend the range of helical ...

  9. Progressive atlanto-axial subluxation in Behcet's disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-hyuk [Chonbuk National University Hospital, Department of Neurosurgery, Jeonju City, Jeonbuk (Korea); Eoh, Whan [Sungkyunkwan University School of Medicine, Samsung Medical Center, Department of Neurosurgery, Seoul (Korea)

    2010-03-15

    Behcet's disease is a chronic inflammatory condition involving several organs, such as the skin, mucous membranes, eyes, joints, intestines, lungs and central nervous system. It rarely affects the spinal column. We describe a case of progressive atlanto-axial subluxation in a 44-year-old woman with Behcet's disease. The patient started complaining of posterior neck pain 10 years after the diagnosis of her Behcet's disease. Initial radiographs showed no abnormal finding, but follow-up radiographs 6 month later demonstrated atlanto-axial subluxation. To the best of our knowledge, this is the second reported case in the worldwide literature of an atlanto-axial instability in a patient with Behcet's disease. (orig.)

  10. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  11. High-resolution optical coherence tomography using broadband light source with strain-controlled InAs/GaAs quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Tsubaki, Ippei; Harada, Yukihiro; Kita, Takashi [Department of Electrical and Electronic Engineering, Graduate School of Engineering, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan)

    2012-12-15

    Recently, there has been an increasing interest in broadband light sources to develop a biomolecular imaging technique called optical coherence tomography (OCT). We fabricated superluminescent diodes (SLDs) using three kinds of quantum dot (QD) layers with different emission wavelength in the active region. The emission wavelength was controlled by reducing the strain in QDs by using In{sub 0.1}Ga{sub 0.9}As strain-reducing layer. The SLD device showed a broad electroluminescence spectrum with the center wavelength of 1104 nm and the spectral linewidth of 122 nm at the injection of 40 mA, which corresponds to the theoretical axial resolution of 4.4 {mu}m. To estimate the actual resolution of the OCT system using fabricated SLD, we measured the interference signal in the Michelson interferometer. An axial resolution of 5.4 {mu}m, which is close to the theoretical limit, was obtained (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. Axial sidelobe reduction in single-photon 4Pi microscopy by Toraldo filters

    International Nuclear Information System (INIS)

    Martinex-Corral, M.; Pons, A.; Caballero, M.T.

    2002-01-01

    Full text: The 4Pi-confocal fluorescence microscope is a recently developed 3D imaging technique in which two opposing high-NA objectives are used for coherently illuminating and/or detecting the same point of the fluorescent sample. The interference process yields an intensity point spread function (PSF) with an extremely narrow axial core, but with very large axial sidelobes, which compromise the actual improvement in axial resolution. To overcome this problem we propose the use, in the illumination arm of the 4Pi-confocal microscope, of multiple-zones phase filters whose design is based on the Toraldo-design principle. Note that the Toraldo procedure allows to select at will the positions of the zeros of the PSF of an optical system. Then, what we propose here if to design a phase pupil filter such that the position of the first zero of the illumination axial PSF is close to the position of the maximum of the first axial sidelobe of the detection PSF. In the design procedure it is taken into account that: 1. The value of the parameter ε = λ exc /λ det which, in a single-photon fluorescent process, is the responsible for the different scales of the illumination and detection PSFs. 2. The Toraldo procedure was originally designed to control the position of zeros of the transverse PSF. In this case the procedure is adapted to the aim of controlling the position of zeros of the axial PSF. 3. Since 4Pi-confocal microscopes are only useful when built with high-NA objectives, the Toraldo principle is reformulated in terms of the nonparaxial diffraction theory. We show that by using Toraldo filters in the illumination part of a 4Pi-confocal microscope it is possible to obtain up to a 60% reduction of height of the axial sidelobe of the whole-system axial PSF. This fact permits to fully benefit the axial resolution from the strong narrowness of the central peak of the axial PSF, inherent to the 4Pi principle. Copyright (2002) Australian Society for Electron Microscopy

  13. Axial structure of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Veronique Bernard; Latifa Elouadrhiri; Ulf-G Meissner

    2002-01-01

    We review the current status of experimental and theoretical understanding of the axial nucleon structure at low and moderate energies. Topics considered include (quasi)elastic (anti)neutrino-nucleon scattering, charged pion electroproduction off nucleons and ordinary as well as radiative muon capture on the proton.

  14. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  15. Method to Measure Tone of Axial and Proximal Muscle

    Science.gov (United States)

    Gurfinkel, Victor S.; Cacciatore, Timothy W.; Cordo, Paul J.; Horak, Fay B.

    2011-01-01

    The control of tonic muscular activity remains poorly understood. While abnormal tone is commonly assessed clinically by measuring the passive resistance of relaxed limbs1, no systems are available to study tonic muscle control in a natural, active state of antigravity support. We have developed a device (Twister) to study tonic regulation of axial and proximal muscles during active postural maintenance (i.e. postural tone). Twister rotates axial body regions relative to each other about the vertical axis during stance, so as to twist the neck, trunk or hip regions. This twisting imposes length changes on axial muscles without changing the body's relationship to gravity. Because Twister does not provide postural support, tone must be regulated to counteract gravitational torques. We quantify this tonic regulation by the restive torque to twisting, which reflects the state of all muscles undergoing length changes, as well as by electromyography of relevant muscles. Because tone is characterized by long-lasting low-level muscle activity, tonic control is studied with slow movements that produce "tonic" changes in muscle length, without evoking fast "phasic" responses. Twister can be reconfigured to study various aspects of muscle tone, such as co-contraction, tonic modulation to postural changes, tonic interactions across body segments, as well as perceptual thresholds to slow axial rotation. Twister can also be used to provide a quantitative measurement of the effects of disease on axial and proximal postural tone and assess the efficacy of intervention. PMID:22214974

  16. Modelling larval transport in a axial convergence front

    Science.gov (United States)

    Robins, P.

    2010-12-01

    Marine larvae exhibit different vertical swimming behaviours, synchronised by factors such as tidal currents and daylight, in order to aid retention near the parent populations and hence promote production, avoid predation, or to stimulate digestion. This paper explores two types of larval migration in an estuarine axial convergent front which is an important circulatory mechanism in many coastal regions where larvae are concentrated. A parallelised, three-dimensional, ocean model was applied to an idealised estuarine channel which was parameterised from observations of an axial convergent front which occurs in the Conwy Estuary, U.K. (Nunes and Simpson, 1985). The model successfully simulates the bilateral cross-sectional recirculation of an axial convergent front, which has been attributed to lateral density gradients established by the interaction of the lateral shear of the longitudinal currents with the axial salinity gradients. On the flood tide, there is surface axial convergence whereas on the ebb tide, there is (weaker) surface divergence. Further simulations with increased/decreased tidal velocities and with stronger/weaker axial salinity gradients are planned so that the effects of a changing climate on the secondary flow can be understood. Three-dimensional Lagrangian Particle Tracking Models (PTMs) have been developed which use the simulated velocity fields to track larvae in the estuarine channel. The PTMs take into account the vertical migrations of two shellfish species that are commonly found in the Conwy Estuary: (i) tidal migration of the common shore crab (Carcinus maenas) and (ii), diel (daily) migration of the Great scallop (Pecten maximus). These migration behaviours are perhaps the most widespread amongst shellfish larvae and have been compared with passive (drifting) particles in order to assess their relative importance in terms of larval transport. Preliminary results suggest that the net along-estuary dispersal over a typical larval

  17. Fluoroscopic lumbar interlaminar epidural injections in managing chronic lumbar axial or discogenic pain

    Directory of Open Access Journals (Sweden)

    Manchikanti L

    2012-08-01

    Full Text Available Laxmaiah Manchikanti,1,2 Kimberly A Cash,1 Carla D McManus,1 Vidyasagar Pampati,1 Ramsin Benyamin3,41Pain Management Center of Paducah, Paducah, KY; 2University of Louisville, Louisville, KY; 3Millennium Pain Center, Bloomington, IL; 4University of Illinois, Urbana-Champaign, IL, USAAbstract: Among the multiple causes of chronic low back pain, axial and discogenic pain are common. Various modalities of treatments are utilized in managing discogenic and axial low back pain including epidural injections. However, there is a paucity of evidence regarding the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. In an interventional pain management practice in the US, a randomized, double-blind, active control trial was conducted. The objective was to assess the effectiveness of lumbar interlaminar epidural injections of local anesthetic with or without steroids for managing chronic low back pain of discogenic origin. However, disc herniation, radiculitis, facet joint pain, or sacroiliac joint pain were excluded. Two groups of patients were studied, with 60 patients in each group receiving either local anesthetic only or local anesthetic mixed with non-particulate betamethasone. Primary outcome measures included the pain relief-assessed by numeric rating scale of pain and functional status assessed by the, Oswestry Disability Index, Secondary outcome measurements included employment status, and opioid intake. Significant improvement or success was defined as at least a 50% decrease in pain and disability. Significant improvement was seen in 77% of the patients in Group I and 67% of the patients in Group II. In the successful groups (those with at least 3 weeks of relief with the first two procedures, the improvement was 84% in Group I and 71% in Group II. For those with chronic function-limiting low back pain refractory to conservative management

  18. Axial loaded MRI of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Saifuddin, A. E-mail: asaifuddin@aol.com; Blease, S.; MacSweeney, E

    2003-09-01

    Magnetic resonance imaging is established as the technique of choice for assessment of degenerative disorders of the lumbar spine. However, it is routinely performed with the patient supine and the hips and knees flexed. The absence of axial loading and lumbar extension results in a maximization of spinal canal dimensions, which may in some cases, result in failure to demonstrate nerve root compression. Attempts have been made to image the lumbar spine in a more physiological state, either by imaging with flexion-extension, in the erect position or by using axial loading. This article reviews the literature relating to the above techniques.

  19. Cross-flow filtration and axial filtration

    International Nuclear Information System (INIS)

    Kraus, K.A.

    1974-01-01

    Two relatively novel alternative solid-liquid-separation techniques of filtration are discussed. In cross-flow filtration, the feed is pumped past the filtering surface. While in axial filtration the filter, mounted on a rotor, is moved with respect to the feed. While large-scale application of the axial filter is still in doubt, it permits with little expenditure of time and money, duplication of many hydrodynamic aspects of cross-flow filtration for fine-particle handling problems. The technique has been applied to municipal wastes, low-level radioactive waste treatment plant, lead removal from industrial wastes, removal of pulp-mill contaminants, textile-mill wastes, and pretreatment of saline waters by lime-soda process in preparation for hyperfiltration. Economics and energy requirements are also discussed

  20. Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis

    Science.gov (United States)

    Armstrong, James J.; Pintwala, Robert; Hutnik, Cindy

    2018-01-01

    Purpose Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). Patients 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Methods Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. Results 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887–0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869–0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835–0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754–0.834, n = 1063 eyes). Conclusion The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options. PMID:29300765

  1. Development of Performance Analysis Program for an Axial Compressor with Meanline Analysis

    International Nuclear Information System (INIS)

    Park, Jun Young; Park, Moo Ryong; Choi, Bum Suk; Song, Je Wook

    2009-01-01

    Axial-flow compressor is one of the most important parts of gas turbine units with axial turbine and combustor. Therefore, precise prediction of performance is very important for development of new compressor or modification of existing one. Meanline analysis is a simple, fast and powerful method for performance prediction of axial-flow compressors with different geometries. So, Meanline analysis is frequently used in preliminary design stage and performance analysis for given geometry data. Much correlations for meanline analysis have been developed theoretically and experimentally for estimating various types of losses and flow deviation angle for long time. In present study, meanline analysis program was developed to estimate compressor losses, incidence angles, deviation angles, stall and surge conditions with many correlations. Performance prediction of one stage axial compressors is conducted with this meanline analysis program. The comparison between experimental and numerical results show a good agreement. This meanline analysis program can be used for various types of single stage axial-flow compressors with different geometries, as well as multistage axial-flow compressors

  2. Xenon-induced axial power oscillations in the 400 MW PBMR

    International Nuclear Information System (INIS)

    Strydom, Gerhard

    2008-01-01

    The redistribution of the spatial xenon concentration in the 400 MW Pebble Bed Modular Reactor (PBMR) core has a non-linear, time-dependent feedback effect on the spatial power density during several types of operational transient events. Due to the inherent weak coupling that exists between the iodine and xenon formation and destruction rates, as well as the complicating effect of spatial variance in the thermal flux field, reactor cores have been analyzed for a number of decades for the occurrence and severity of xenon-induced axial power oscillations. Of specific importance is the degree of oscillation damping exhibited by the core during transients, which involves axial variations in the local power density. In this paper the TINTE reactor dynamics code is used to assess the stability of the current 400 MW PBMR core design with regard to axial xenon oscillations. The focus is mainly on the determination of the inherent xenon and power oscillation damping properties by utilizing a set of hypothetical control rod insertion transients at various power levels. The oscillation damping properties of two 100%-50%-100% load-follow transients, one of which includes the de-stabilizing axial effects of moving control rods, are also discussed in some detail. The study shows that, although first axial mode oscillations do occur in the 400 MW PBMR core, the inherent damping of these oscillations is high, and that none of the investigated load-follow transients resulted in diverging oscillations. It is also shown that the PBMR core exhibits no radial oscillation components for these xenon-induced axial power oscillations

  3. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  4. Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

    Science.gov (United States)

    Liang, Kaicheng; Wang, Zhao; Ahsen, Osman O.; Lee, Hsiang-Chieh; Potsaid, Benjamin M.; Jayaraman, Vijaysekhar; Cable, Alex; Mashimo, Hiroshi; Li, Xingde; Fujimoto, James G.

    2018-01-01

    Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm × 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 μm wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 × 2322 axial scans with 8.5 μm axial and 30 μm transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy. PMID:29682598

  5. A study on multi-axial fatigue model based on structural stress

    International Nuclear Information System (INIS)

    Kim, Cheol; Kim, Jong Sung; Jin, Tae Eun; Dong, P.

    2004-01-01

    In nuclear components, cyclic loadings that cause complex states of stress are common. Through a reference review, four sources of the multi-axial fatigue data were collected from LBF, University of Illinois, EPRI, and TWI. All these tests were conducted using tube to flange specimens with a circumferential fillet welds. The loading conditions were mostly bending/ torsion combinations, except that TWI used tension/ torsion combinations. None of fatigue correlation parameters have been demonstrated to be satisfactory in correlating the multi-axial fatigue data outside of their own. In this paper, we proposed the characterizing multi-axial fatigue behavior in terms of the structural stress methods by using some of the well-known multi-axial fatigue data available in the references

  6. Precision axial translator with high stability.

    Science.gov (United States)

    Bösch, M A

    1979-08-01

    We describe a new type of translator which is inherently stable against torsion and twisting. This concentric translator is also ideally suited for precise axial motion with clearance of the center line.

  7. Axially modulated arch resonator for logic and memory applications

    KAUST Repository

    Hafiz, Md Abdullah Al

    2018-01-17

    We demonstrate reconfigurable logic and random access memory devices based on an axially modulated clamped-guided arch resonator. The device is electrostatically actuated and the motional signal is capacitively sensed, while the resonance frequency is modulated through an axial electrostatic force from the guided side of the microbeam. A multi-physics finite element model is used to verify the effectiveness of the axial modulation. We present two case studies: first, a reconfigurable two-input logic gate based on the linear resonance frequency modulation, and second, a memory element based on the hysteretic frequency response of the resonator working in the nonlinear regime. The energy consumptions of the device for both logic and memory operations are in the range of picojoules, promising for energy efficient alternative computing paradigm.

  8. Age estimation by pulp-to-tooth area ratio using cone-beam computed tomography: A preliminary analysis.

    Science.gov (United States)

    Rai, Arpita; Acharya, Ashith B; Naikmasur, Venkatesh G

    2016-01-01

    Age estimation of living or deceased individuals is an important aspect of forensic sciences. Conventionally, pulp-to-tooth area ratio (PTR) measured from periapical radiographs have been utilized as a nondestructive method of age estimation. Cone-beam computed tomography (CBCT) is a new method to acquire three-dimensional images of the teeth in living individuals. The present study investigated age estimation based on PTR of the maxillary canines measured in three planes obtained from CBCT image data. Sixty subjects aged 20-85 years were included in the study. For each tooth, mid-sagittal, mid-coronal, and three axial sections-cementoenamel junction (CEJ), one-fourth root level from CEJ, and mid-root-were assessed. PTR was calculated using AutoCAD software after outlining the pulp and tooth. All statistical analyses were performed using an SPSS 17.0 software program. Linear regression analysis showed that only PTR in axial plane at CEJ had significant age correlation ( r = 0.32; P < 0.05). This is probably because of clearer demarcation of pulp and tooth outline at this level.

  9. Investigation on a procedure for optimal axial depth of cut accuracy in micromilling

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    On the basis of a previously developed procedure for control of axial depth of cut in high accuracy micromilling operations, this paper presents an investigation on the estimation of the uncertainty of the set axial depth of cut.......On the basis of a previously developed procedure for control of axial depth of cut in high accuracy micromilling operations, this paper presents an investigation on the estimation of the uncertainty of the set axial depth of cut....

  10. Asymptotic freedom in the axial and Coulomb gauges

    International Nuclear Information System (INIS)

    Frenkel, J.; Taylor, J.C.

    1976-01-01

    The sources of the negative contribution to the charge renormalization factor gsup(B)/g-1 in Yang-Mills theories are investigated in the axial and Coulomb gauges. In the axial gauge, a Kaellen dispersion relation exists but the spectral function is not positive definite because of the prescription that is used to integrate the singular polarization vectors. In the Coulomb gauge, the negative contributions are (to the lowest order) isolated in the Coulomb self-energy corrections to the Coulomb field. (Auth.)

  11. Effects of axial coordination on immobilized Mn(salen) catalysts.

    Science.gov (United States)

    Teixeira, Filipe; Mosquera, Ricardo A; Melo, André; Freire, Cristina; Cordeiro, M Natália D S

    2014-11-13

    The consequences of anchoring Mn(salen) catalysts onto a supporting material using one of the vacant positions of the metal center are tackled by studying several Mn(salen) complexes with different axial ligands attached. This is accomplished using Density Functional Theory at the X3LYP/Triple-ζ level of theory and the Atom In Molecules formalism. The results suggest that both Mn(salen) complexes and their oxo derivatives should lie in a triplet ground state. Also, the choice of the axial ligand bears a moderate effect on the energy involved in the oxidation of the former to oxo-Mn(salen) complexes, as well as in the stability of such complexes toward ligand removal by HCl. AIM analysis further suggests that the salen ligand acts as a "charge reservoir" for the metal center, with strong correlations being obtained between the charge of salen and the electron population donated by the axial ligand to the metal center. Moreover, the results suggest that the Mn atom in Mn(salen) complexes holds different hybridization of its valence orbitals depending on the type of axial ligand present in the system.

  12. Axial magnetic field restriction of plasma sheath in a coaxial discharge

    International Nuclear Information System (INIS)

    Masoud, M. M.; Soliman, H. M.; Ibrahim, F. A.

    1999-01-01

    The study deals with the effect of an applied axial magnetic field on the dynamics and parameters of the plasma sheath and the expanded plasma in a coaxial discharge. Experimental investigations were carried out with a 3 kJ coaxial discharge device of a Mather geometry. The discharge takes place in Hydrogen gas with base pressure of 1 torr. The experiments were conducted with a 10 kV bank voltage, which corresponds to 100 kA discharge currents. The investigations have shown that the maximum axial plasma sheath velocity is decreased by 20% when applying the external axial magnetic field along the coaxial electrodes of intensity 2.6 kG. The experimental results of axial magnetic field intensity B z along the coaxial electrodes indicated that the application of external axial magnetic field causes an increases of B z ∼ 40% at a mid-distance between the breech and the muzzle and a decrease by 75% at the muzzle. The experimental results of expanded plasma electron temperature T e and density n e cleared that when the axial magnetic field is applied the maximum T e is decreased by 2.6 and 3 times, while the maximum n e is increased by 2.8 and 2 times for the first and second half cycles respectively. (author)

  13. Mandibular condylar fractures and acute atlanto-axial subluxation Part 2 A physiopathological factor for the cervical spine sprain.

    Science.gov (United States)

    Cutilli, T; Corbacelli, A

    2009-05-01

    The aim of this study was to analyze the physiopathology of the acute cervical injure in the event of mandibular condylar fractures. As in the Part 1, 25 non-consecutive cases of condylar mandibular fractures (16 males and 9 females, mean age: 22.96/range 14-36 years) observed and treated in the Maxillofacial Surgery Department of the University of L'Aquila, have been studied. Types of fractures examined included: unilateral: 19 cases (solitary: 12; associated with other mandibular fractures: 7, homolateral: 2); bilateral: 6 cases (equivalent: 2, not equivalent: 4). A control group was constituted of 10 patients, 5 males and 5 females, aged from 19 to 24 years (mean range: 21.6) suffering from acute isolated cervical distorsion (whiplash). The study has been performed by means of the analysis of X-ray and computed tomography (CT)-CT/3D of the mandibular condylar regions, the occipital-atlanto-axial structures and the cervical region. In all the patients the following constant alterations that link up with these fractures have been observed: the rotation of atlas, the atlanto-axial subluxation and the derangement of the occipital-atlanto-epistropheal joint, homolateral to the side of the mandibular condylar fracture. The cervical spine shows the constant loss of physiological lordosis with hinge between C3 and C4. In the whiplash, as the authors have been able to assess in the control group, there are no alterations of occipital-atlanto-axial joint and the kinetic vector is placed on the longitudinal plane. In the mandibular condylar fractures the kinetic mechanism is completely different regarding the whiplash. The point of entry is the chin and the kinetic vector is oriented down-up, sometimes oblique in the opposite side. Subsequently the kinetic force is transmitted throughout the mandibular structure and causes the condylar or bicondylar fracture. The kinetic vector is placed before on the vertical plane, then on the horizontal plane and later on the vertical

  14. Efficient Propulsion Structure with an Axial Flux Rotary Converter for HEV Drive Unit

    Directory of Open Access Journals (Sweden)

    Ales Havel

    2011-01-01

    Full Text Available This paper describes an efficient axial flux arrangement of the four quadrant rotary converter for hybrid electric vehicles. The design of the axial flux wound stator and both axial flux squirrel cage rotors is based on the arrangement of radial air gap induction motor and permanent magnet synchronous motor. The method of constant magnetic circuit volume is utilized for dimensions conversion, which results into basic dimensions of stator and rotor discs in axial flux conception. This allows the creation of real 3D models in the CAD application. Finally, the finite element simulations of electromagnetic induction in the axial flux stator pack are presented in the concluding part of this paper.

  15. Axial and radial velocities in the creeping flow in a pipe

    Directory of Open Access Journals (Sweden)

    Zuykov Andrey L'vovich

    2014-05-01

    Full Text Available The article is devoted to analytical study of transformation fields of axial and radial velocities in uneven steady creeping flow of a Newtonian fluid in the initial portion of the cylindrical channel. It is shown that the velocity field of the flow is two-dimensional and determined by the stream function. The article is a continuation of a series of papers, where normalized analytic functions of radial axial distributions in uneven steady creeping flow in a cylindrical tube with azimuthal vorticity and stream function were obtained. There is Poiseuille profile for the axial velocity in the uniform motion of a fluid at an infinite distance from the entrance of the pipe (at x = ∞, here taken equal to zero radial velocity. There is uniform distribution of the axial velocity in the cross section at the tube inlet at x = 0, at which the axial velocity is constant along the current radius. Due to the axial symmetry of the flow on the axis of the pipe (at r = 0, the radial velocities and the partial derivative of the axial velocity along the radius, corresponding to the condition of the soft function extremum, are equal to zero. The authors stated vanishing of the velocity of the fluid on the walls of the pipe (at r = R , where R - radius of the tube due to its viscous sticking and tightness of the walls. The condition of conservation of volume flow along the tube was also accepted. All the solutions are obtained in the form of the Fourier - Bessel. It is shown that the hydraulic losses at uniform creeping flow of a Newtonian fluid correspond to Poiseuille - Hagen formula.

  16. Axial length elongation in adults with long-standing unilateral traumatic cataract

    Directory of Open Access Journals (Sweden)

    Jonel Steffen

    2016-09-01

    Full Text Available Background: Unilateral eye elongation with resultant axial myopia has been reported to occur secondary to visual deprivation from birth or early childhood. Acquired axial length elongation secondary to visual deprivation in adults has rarely been reported. Aim: To report acquired axial myopia in adults with visual deprivation due to long-standing unilateral traumatic cataract. Methods: Eleven consecutive adult patients who presented for cataract surgery with unilateral, long-standing, mature, traumatic cataracts and an interocular axial length difference of more than 1 mm were studied. Patients with a post-operative best corrected visual acuity (BCVA of < 6/12 were excluded to rule out possible pre-existing anisometropic amblyopia. Results: Of the 11 patients with significant interocular axial length difference, 5 patients were excluded on the basis of possible pre-existing amblyopia. The remaining 6 patients had final BCVA of 6/12 or better. The median length of the cataractous eyes was 2.83 mm longer than the fellow eyes (range 1.12 mm – 3.52 mm. The intraocular lens power required for emmetropia was 6.8 dioptres (range 3.5 dioptres – 11.5 dioptres less in the cataractous eyes. A refractive outcome within 1 dioptre of the target refraction was achieved in all patients. The median delay between ocular trauma and cataract surgery was 20 years (range 8–24 years. Conclusion: Significant unilateral axial length elongation may occur in adults with longstanding traumatic cataracts and visual deprivation. A potential correlation may exist between delay to surgery and degree of axial length difference. This rare phenomenon must be considered when determining intraocular lens power to avoid post-operative refractive surprises.

  17. Computational analysis of a multistage axial compressor

    Science.gov (United States)

    Mamidoju, Chaithanya

    Turbomachines are used extensively in Aerospace, Power Generation, and Oil & Gas Industries. Efficiency of these machines is often an important factor and has led to the continuous effort to improve the design to achieve better efficiency. The axial flow compressor is a major component in a gas turbine with the turbine's overall performance depending strongly on compressor performance. Traditional analysis of axial compressors involves throughflow calculations, isolated blade passage analysis, Quasi-3D blade-to-blade analysis, single-stage (rotor-stator) analysis, and multi-stage analysis involving larger design cycles. In the current study, the detailed flow through a 15 stage axial compressor is analyzed using a 3-D Navier Stokes CFD solver in a parallel computing environment. Methodology is described for steady state (frozen rotor stator) analysis of one blade passage per component. Various effects such as mesh type and density, boundary conditions, tip clearance and numerical issues such as turbulence model choice, advection model choice, and parallel processing performance are analyzed. A high sensitivity of the predictions to the above was found. Physical explanation to the flow features observed in the computational study are given. The total pressure rise verses mass flow rate was computed.

  18. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  19. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  20. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  1. Capillary red blood cell velocimetry by phase-resolved optical coherence tomography.

    Science.gov (United States)

    Tang, Jianbo; Erdener, Sefik Evren; Fu, Buyin; Boas, David A

    2017-10-01

    We present a phase-resolved optical coherence tomography (OCT) method to extend Doppler OCT for the accurate measurement of the red blood cell (RBC) velocity in cerebral capillaries. OCT data were acquired with an M-mode scanning strategy (repeated A-scans) to account for the single-file passage of RBCs in a capillary, which were then high-pass filtered to remove the stationary component of the signal to ensure an accurate measurement of phase shift of flowing RBCs. The angular frequency of the signal from flowing RBCs was then quantified from the dynamic component of the signal and used to calculate the axial speed of flowing RBCs in capillaries. We validated our measurement by RBC passage velocimetry using the signal magnitude of the same OCT time series data.

  2. Imaging features suggestive of a conjoined nerve root on routine axial MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Su Jin; Lee, Joon Woo; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Gyeongi-do (Korea); Choi, Ja-Young; Hong, Sung Hwan; Kim, Na Ra [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Ki-Jeong; Chung, Sang-Ki; Kim, Hyun-Jib [Seoul National University Bundang Hospital, Department of Neurosurgery, Gyeongi-Do (Korea)

    2008-02-15

    The purpose of our study is to evaluate imaging features suggestive of a conjoined nerve root on routine axial MRI. Two radiologists and two surgeons retrospectively reviewed the MRI of three cases in which a conjoined nerve root was discovered during operation and found three suggestive signs on routine axial MR images: ''corner'' (asymmetric morphology of the anterolateral corner of the dural sac), ''fat crescent'' (intervening extradural fat between the asymmetric dura and the nerve root), and ''parallel'' signs (visualization of the entire parallel course of the nerve root at the disc level). Two radiologists prospectively found these signs during routine MRI interpretation sessions over a period of 6 months. If one or a combination of signs were noted on axial MR images, contiguous axial scans were additionally obtained. Three cases that were previously found during operations were also included. Prevalence and confidence scores for each sign were assessed on axial T1- and T2-weighted images. Twelve patients showed one or a combination of the three signs, 9 had contiguous axial MR scans. Five cases were confirmed by operation. The prevalence of the corner, fat crescent, and parallel signs were 12 out of 12 (100%), 6 out of 12 (50%), and 8 out of 12 (67.7%) on axial T1-weighted images. The overall diagnostic confidence was higher on T1- than on T2-weighted images (P < 0.05). On routine axial L-spine MRI, corner, fat crescent, and parallel signs are suggestive of and assist in the recognition of a conjoined nerve root. (orig.)

  3. Evidence of shallow gas in the Queen Charlotte Basin from waveform tomography of seismic reflection data

    Energy Technology Data Exchange (ETDEWEB)

    Takam Takougang, Eric M.; Calvert, Andrew J. [Simon Fraser University (Canada)], email: eta9@sfu.ca

    2011-07-01

    The Geological Survey of Canada (GSC) collected eight seismic reflection lines in 1988 across the Queen Charlotte sedimentary basin of western Canada, which is the largest tertiary basin on the west coast. This work furthers the study of the upper part of the basin by using quantitative imaging of its structure through application of 2-D waveform tomography to the limited offset seismic reflection data. With the help of waveform tomography, seismic reflection data has allowed the identification of pockmark structures and pipe-like gas chimney in the recovered velocity and attenuation models. Overall, there is an excellent match between field data and predicted data. and a good match between the sonic log and a 1-D velocity function derived from the 2-D velocity model. This shows that specific preconditioning of the data and a good inversion strategy make it possible to use waveform tomography of relatively short offset reflection data for the imaging of shallow geological features.

  4. Pion Photo- and Electroproduction and the Partially Conserved Axial Current

    International Nuclear Information System (INIS)

    Haberzettl, Helmut

    2000-01-01

    The relevance of the axial current for pion production processes off the nucleon with real or virtual photons is revisited. Employing the hypothesis of a partially conserved axial current (PCAC), it is shown that, when all of the relevant contributions are taken into account, PCAC does not provide any additional constraint for threshold production processes that goes beyond the Goldberger-Treiman relation. In particular, it is shown that pion electroproduction processes at threshold cannot be used to extract any information regarding the weak axial form factor. The relationships found in previous investigations are seen to be an accident of the approximations usually made in this context

  5. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  6. Analysis of the results of CAT of thorax with bronchiectasis protocol, period 2000-2001 Hospital Calderon Guardia

    International Nuclear Information System (INIS)

    Pacheco Segura, Maureen

    2003-01-01

    This investigation analyses the computerized axial tomography (CAT) of thorax with protocol of bronchiectasis. It was carried out in the Servicio de Radiologia e Imagenes Medicas of the Hospital Calderon Guardia, Costa Rica. The bronchiectasis is the abnormal permanent expansion of the bronchial tuber and is important to diagnose it because the patient can suffer of pulmonary infections, these can be accompanied by bronchial blood flow and hemoptysis. When they are disseminated can be associated with significant obstruction of the aerial tract. When they are gotten into focus can be confused with neoplasia and other diseases. From the bronchiectasis diagnosis it is used methods of image such as x-ray of thorax, bronchography and computerized axial tomography (CAT) of thorax, usually the diagnosis is confirmed by means of a computerized axial tomography (CAT); which is the image of election to establish the presence and extension of the bronchiectasis. In addition, this study analyzes the radiological clinical relation in the patients which were performed the computerized axial tomography (CAT) of thorax with protocol of bronchiectasis and it identifies the most suitable radiological technique to obtain a satisfactory result in the computerized axial tomography with protocol of bronchiectasis [es

  7. The evolutionary origin of the turtle shell and its dependence on the axial arrest of the embryonic rib cage.

    Science.gov (United States)

    Hirasawa, Tatsuya; Pascual-Anaya, Juan; Kamezaki, Naoki; Taniguchi, Mari; Mine, Kanako; Kuratani, Shigeru

    2015-05-01

    Turtles are characterized by their possession of a shell with dorsal and ventral moieties: the carapace and the plastron, respectively. In this review, we try to provide answers to the question of the evolutionary origin of the carapace, by revising morphological, developmental, and paleontological comparative analyses. The turtle carapace is formed through modification of the thoracic ribs and vertebrae, which undergo extensive ossification to form a solid bony structure. Except for peripheral dermal elements, there are no signs of exoskeletal components ontogenetically added to the costal and neural bones, and thus the carapace is predominantly of endoskeletal nature. Due to the axial arrest of turtle rib growth, the axial part of the embryo expands laterally and the shoulder girdle becomes encapsulated in the rib cage, together with the inward folding of the lateral body wall in the late phase of embryogenesis. Along the line of this folding develops a ridge called the carapacial ridge (CR), a turtle-specific embryonic structure. The CR functions in the marginal growth of the carapacial primordium, in which Wnt signaling pathway might play a crucial role. Both paleontological and genomic evidence suggest that the axial arrest is the first step toward acquisition of the turtle body plan, which is estimated to have taken place after the divergence of a clade including turtles from archosaurs. The developmental relationship between the CR and the axial arrest remains a central issue to be solved in future. © 2014 Wiley Periodicals, Inc.

  8. Clinical impact of Positron Emission Tomography (PET) on oncological patients and their potentially application context

    International Nuclear Information System (INIS)

    Alonso, O.

    2006-01-01

    (PET) Positron Emission Tomography is a technique of nuclear medicine that has ability of detecting cancer through mechanisms based on molecular alterations of neoplastic processes. This review describes the PET Oncology applications and discusses the potential application of this technology in the sanitary and national academic framework . The most widely used in Oncology plotter is an analogue of laglucosa labelled with fluo: 18F-2-fluoro-2-Deoxy-D-glucose (FDG). In this way, the PET detects tumour retention of FDG, due to the highest glycolytic of cancer cells. In addition, the PET allow the study of the entire body at the same exploratory and some teams are coupled to systems of axial tomography (PET-CT). By ET-FDG, it is possible to diagnose, staging and restaged the majority of cancers, with diagnostic accuracy close to 90 per cent higher than the values provided by the conventional imaging techniques such. It is also possible to know early response to cancer treatments and obtain relevant medical prognosis information. (author) [es

  9. Observed Incidence of Uveitis Following Certolizumab Pegol Treatment in Patients With Axial Spondyloarthritis

    NARCIS (Netherlands)

    Rudwaleit, M.; Rosenbaum, J. T.; Landewé, R.; Marzo-Ortega, H.; Sieper, J.; van der Heijde, D.; Davies, O.; Bartz, H.; Hoepken, B.; Nurminen, T.; Deodhar, A.

    2016-01-01

    Axial spondyloarthritis (axial SpA) is characterized by inflammation of the spine and sacroiliac joints and can also affect extraarticular sites, with the most common manifestation being uveitis. Here we report the incidence of uveitis flares in axial SpA patients from the RAPID-axSpA trial,

  10. Axial asymmetry of excited heavy nuclei as essential feature for the prediction of level densities

    Energy Technology Data Exchange (ETDEWEB)

    Grosse, Eckart [Institute of Nuclear and Particle Physics, Technische Universitaet Dresden (Germany); Junghans, Arnd R. [Institute of Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf (Germany); Massarczyk, Ralph [Los Alamos National Laboratory, New Mexico (United States)

    2016-07-01

    In previous studies a considerable improvement of predictions for neutron resonance spacings by a modified back-shifted Fermi-gas model (BSFM) was found. The modifications closely follow the basic principles for a gas of weakly bound Fermions as given in text books of statistical physics: (1) Phase transition at a temperature defined by theory, (2) pairing condensation independent of A, and (3) proportionality of entropy to temperature (and thus the level density parameter) fixed by the Fermi energy. For finite nuclei we add: (4) the back-shift energy is defined by shell correction and (5) the collective enhancement is enlarged by allowing the axial symmetry to be broken. Nearly no parameter fitting is needed to arrive at a good reproduction of level density information obtained by various methods for a number of nuclei in a wide range of A and E. To that end the modified BSFM is complemented by a constant temperature approximation below the phase transition point. The axial symmetry breaking (5), which is an evidently essential feature, will also be regarded with respect to other observables for heavy nuclei.

  11. Research on axial thrust of the waterjet pump based on CFD under cavitation conditions

    International Nuclear Information System (INIS)

    Shen, Z H; Pan, Z Y

    2015-01-01

    Based on RANS equations, performance of a contra-rotating axial-flow waterjet pump without hydrodynamic cavitation state had been obtained combined with shear stress transport turbulence model. Its cavitation hydrodynamic performance was calculated and analysed with mixture homogeneous flow cavitation model based on Rayleigh-Plesset equations. The results shows that the cavitation causes axial thrust of waterjet pump to drop. Furthermore, axial thrust and head cavitation characteristic curve is similar. However, the drop point of the axial thrust is postponed by 5.1% comparing with one of head, and the critical point of the axial thrust is postponed by 2.6%

  12. Research on axial thrust of the waterjet pump based on CFD under cavitation conditions

    Science.gov (United States)

    Shen, Z. H.; Pan, Z. Y.

    2015-01-01

    Based on RANS equations, performance of a contra-rotating axial-flow waterjet pump without hydrodynamic cavitation state had been obtained combined with shear stress transport turbulence model. Its cavitation hydrodynamic performance was calculated and analysed with mixture homogeneous flow cavitation model based on Rayleigh-Plesset equations. The results shows that the cavitation causes axial thrust of waterjet pump to drop. Furthermore, axial thrust and head cavitation characteristic curve is similar. However, the drop point of the axial thrust is postponed by 5.1% comparing with one of head, and the critical point of the axial thrust is postponed by 2.6%.

  13. Can Parameters Other than Minimal Axial Diameter in MRI and PET/CT Further Improve Diagnostic Accuracy for Equivocal Retropharyngeal Lymph Nodes in Nasopharyngeal Carcinoma?

    Science.gov (United States)

    Wang, Yu-Wen; Wu, Chin-Shun; Zhang, Guo-Yi; Chang, Chih-Han; Cheng, Kuo-Sheng; Yao, Wei-Jen; Chang, Yu-Kang; Chien, Tsair-Wei; Lin, Li-Ching; Lin, Keng-Ren

    2016-01-01

    Minimal axial diameter (MIAD) in magnetic resonance imaging (MRI) was recognized as the most useful parameter in diagnosing lateral retropharyngeal lymph (LRPL) nodes in nasopharyngeal carcinoma (NPC). This study aims to explore the additional nodal parameters in MRI and positron emission tomography-computed tomography for increasing the prediction accuracy. A total of 663 LRPL nodes were retrospectively collected from 335 patients with NPC. The LRPL nodes ascertained on follow-up MRI were considered positive for metastases. First, the optimal cutoff value of each parameter was derived for each parameter. In addition, neural network (NN) nodal evaluation was tested for all combinations of three parameters, namely MIAD, maximal axial diameter (MAAD), and maximal coronal diameter (MACD). The optimal approach was determined through brute force attack, and the results of two methods were compared using a bootstrap sampling method. Second, the mean standard uptake value (NSUVmean) was added as the fourth parameter and tested in the same manner for 410 nodes in 219 patients. In first and second analysis, the accuracy rate (percentage) for the MIAD was 89.0% (590/663) and 89.0% (365/410), with the optimal cutoff values being 6.1 mm and 6.0 mm, respectively. With the combination of all three and four parameters, the accuracy rate of the NN was 89% (288/332) and 88.8% (182/205), respectively. In prediction, the optimal combinations of the three and four parameters resulted in correct identification of three (accuracy: 593/663, 89.4%) and six additional nodes (371/410, 90.5%), representing 4% (3/73) and 13.3% (6/45) decreases in incorrect prediction, respectively. NPC LRPL nodes with an MIAD ≥ 6.1 mm are positive. Among nodes with an MIAD < 6.1 mm, if the NSUVmean ≥ 2.6 or MACD ≥ 25 mm and MAAD ≥ 8 mm, the nodes are positive; otherwise, they are negative.

  14. GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography

    International Nuclear Information System (INIS)

    Jan, Sebastien; Collot, Johann; Gallin-Martel, Marie-Laure; Martin, Philippe; Mayet, Frederic; Tournefier, Edwige

    2003-01-01

    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object- Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented: the design optimization of a liquid Xe μPET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 μPET camera. Index Terms-Positron Emission Tomography, Monte Carlo Simulation, Geant 4. (authors)

  15. New Sodium Cooled Long-Life Cores with Axially Multi-Driver Regions

    International Nuclear Information System (INIS)

    Hyun, Hae Ri; Hong, Ser Gi

    2014-01-01

    In this concept of long-life core (they are sometimes called B-B (Breed and Burn)), tall blanket is placed above the relatively short driver fuel. In the initial stage of burning, the power by fission is mostly generated in the driver region and it moves into the blanket region. The power and flux distributions that are highly peaked in the axial direction propagates slowly from the driver into the blanket region. This concept of long-life core fully utilizes the breeding of blanket in the fast spectra and it can achieve very high burnup of fuel. In this work, we introduce new sodium cooled longlife cores rating 600MWe (1800MWt). In these cores, the driver regions are heterogeneously placed into blanket region so as to achieve stabilized and less peaked axial power distribution as depletion proceeds. At present, our study is focused on only two axial driver regions but this concept can be easily extended onto the multi-driver region concept. The cores designed in this paper have two axial driver regions so as to have stabilized and less peaked axial power distributions as depletion proceeds. The results of the core design and analyses show that the cores have very long-lives longer than -49EFPYs and high discharge burnup higher than 200GWD/kg. Additionally, we considered a long-life core having no blanket. As expected, it was shown that these cores have stabilized and less peaked axial power distribution as the fuel depletes. However, the study shows that the cores having two driver regions still show high initial peaking of the axial power distributions and the core can be optimized by changing the driver fuel height

  16. Thermal characterization of phacoemulsification probes operated in axial and torsional modes.

    Science.gov (United States)

    Zacharias, Jaime

    2015-01-01

    To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. Experimental study. Two computer-controlled thermal transfer systems were developed to evaluate the contribution of internal metal stress and tip-to-sleeve friction on heat generation during phacoemulsification using axial and torsional ultrasound modalities. Both systems incorporated infrared thermal imaging and used a black-body film to accurately capture temperature measurements. Axial mode was consistently associated with greater temperature increases than torsional mode whether tips were operated with or without sleeves. In tests involving bare tips, axial mode and torsional mode peaked at 51.7°C and 34.2°C, respectively. In an example using sleeved tips in which a 30.0 g load was applied for 1 second, temperatures for axial mode reached 45°C and for torsional mode, 38°C. Friction between the sleeved probe and the incisional wall contributed more significantly to the temperature increase than internal metal stress regardless of the mode used. In all experiments, the temperature increase observed with axial mode was greater than that observed with torsional mode, even when conditions such as power or amplitude and flow rate were varied. Tip-to-sleeve friction was a more dominant source of phaco probe heating than internal metal stress. The temperature increase due to internal metal stress was greater with axial mode than with torsional mode. Dr. Zacharias received research funding from Alcon Laboratories, Inc., to conduct this study. He has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  18. Calculation of core axial power shapes using alternating conditional expectation algorithm

    International Nuclear Information System (INIS)

    Lee, Eun Ki; Kim, Yong Hee; Cha, Kune Ho; Park, Moon Kyu

    1998-01-01

    We have introduced the alternating conditional expectation (ACE) algorithm in the method of reconstructing 20 node axial power shapes from five level detector powers. The ACE algorithm was used to find the optimal relationships between each plane power and normalized five detector powers. The obtained all optimal transformations had simple forms to be represented with polynomials. The reference axial power shapes and simulated detector powers were drawn out of the 3-dimensional results of Reactor Operation and Control Simulation (ROCS) code for various core states. By the ACE algorithm, we obtained the optimal relationship between dependent variable plane power, y, and independent variable detector powers, {Di, i=1,...,5 without any preprocessing, where a total of ≅3490 data sets per each cycle of YongGwang Nuclear (YGN) Power Plant units 3 and 4 are used. To test the validity and accuracy of the new method, about 21,200 cases of reconstructed axial power shapes are compared to original ROCS axial power shapes, and they are also contrasted with those obtained by Fourier fitting method (FFM). The average error of root mean square (rms), axial peak (DFZ), and axial shape index (DASI) of our new method for total 21204 data cases are 0.81%, 0.51% and 0.00204, while FFM 2.29%, 2.37% and 0.00264, respectively. The evaluation results for the data sets not used in the ACE transformations also show that the accuracy of new method is much better than that of FFM

  19. Optimización de Estatores para Motores Superconductores de Flujo Axial Optimización de Estatores para Motores Superconductores de Flujo Axial

    Directory of Open Access Journals (Sweden)

    Oscar Gerardo Ibarra-Manzano

    2012-02-01

    Full Text Available The development of superconducting electrical machines has been designed primarily to design and build engines with the superconducting magnetic field in radial configuration, as traditional engines, so the design and construction of rotating electrical machines in axial flow configuration has become an alternative for the design and construction of such engines. In this paper we present preliminary calculations for the optimization of the stator of a superconducting motor in axial flow confi guration, based on the equations of general power of the rotary axial flow configuration. It performs the construction, optimization and evaluation of models of stators in geometries of 4, 6 and 8 poles with high-temperature superconducting tapes of Bismuth. The results show the feasibility of the design implemented, which is verified by a significant decrease in the current of superconducting motor operation.El desarrollo de máquinas eléctricas superconductoras ha estado encaminado principalmentea diseñar y construir motores superconductores con el campo magnético en configuración radial, como los motores tradicionales, por lo que el diseño y construcción demáquinas eléctricas rotativas en configuración de flujo axial ha venido a ser una alternativa para el diseño y construcción de este tipo de motores. En el presente trabajo se presentan los cálculos preliminares para la optimización del estator de un motor superconductor en configuración de flujo axial, basados en las ecuaciones generales de potencia de las máquinas eléctricas rotativas en configuración flujo axial ha venido a ser una alternativa para el diseño y construcción, optimización y evaluación de modelos de estatores en geometrías de 4, 6 y 8 polos, con cintas superconductoras de alta temperatura de Bismuto. Los resultados obtenidos muestran la viabilidaddel diseño implementado, lo cual se comprueba por medio de una disminución significativa de la corriente de operaci

  20. CONTRIBUTION OF AXIAL MOTOR IMPAIRMENT TO PHYSICAL INACTIVITY IN PARKINSON'S DISEASE

    Science.gov (United States)

    Bryant, Mon S; Hou, Jyhgong Gabriel; Collins, Robert L; Protas, Elizabeth J

    2015-01-01

    Objective To investigate the relationships between motor symptoms of Parkinson’s disease (PD) and activity limitations in persons with PD. Design/Methods Cross-sectional study of persons with mild to moderate PD (N=90). Associations among axial motor features, limb motor signs, the Physical Activity Scale for Elders (PASE), the ability to perform Activities of Daily Living (ADL) and level of ADL dependency were studied. A composite score of axial motor features included the following UPDRS items: speech, rigidity of the neck, arising from chair, posture, gait and postural stability. A composite score of limb motor signs included the following UPDRS items: tremor at rest of all extremities, action tremor, rigidity of all extremities, finger taps, hand movement, rapid alternating hand movements and foot tapping. Results Axial motor features of PD were significantly correlated with physical inactivity (pphysical inactivity. After controlling for age, gender, disease duration and comorbidity, axial motor features contributed significantly to physical inactivity, decreased ADL and increase in ADL dependency, whereas the limb motor signs did not. Conclusions Axial motor impairment contributed to physical inactivity and decreased ability to perform ADLs in persons with PD. PMID:26368837

  1. Visualization of bonding at an inclusion boundary using axial-shear strain elastography: a feasibility study

    International Nuclear Information System (INIS)

    Thitaikumar, Arun; Krouskop, Thomas A; Garra, Brian S; Ophir, Jonathan

    2007-01-01

    Ultrasound elastography produces strain images of compliant tissues under quasi-static compression. In axial-shear strain elastography, the local axial-shear strain resulting from application of quasi-static axial compression to an inhomogeneous material is imaged. The overall hypothesis of this work is that the pattern of axial-shear strain distribution around the inclusion/background interface is completely determined by the bonding at the interface after normalization for inclusion size and applied strain levels, and that it is feasible to extract certain features from the axial-shear strain elastograms to quantify this pattern. The mechanical model used in this study consisted of a single stiff circular inclusion embedded in a homogeneous softer background. First, we performed a parametric study using finite-element analysis (FEA) (no ultrasound involved) to identify possible features that quantify the pattern of axial-shear strain distribution around an inclusion/background interface. Next, the ability to extract these features from axial-shear strain elastograms, estimated from simulated pre- and post-compression noisy RF data, was investigated. Further, the feasibility of extracting these features from in vivo breast data of benign and malignant tumors was also investigated. It is shown using the FEA study that the pattern of axial-shear strain distribution is determined by the degree of bonding at the inclusion/background interface. The results suggest the feasibility of using normalized features that capture the region of positive and negative axial-shear strain area to quantify the pattern of the axial-shear strain distribution. The simulation results showed that it was feasible to extract the features, as identified in the FEA study, from axial-shear strain elastograms. However, an effort must be made to obtain axial-shear strain elastograms with the highest signal-to-noise ratio (SNR asse ) possible, without compromising the resolution. The in vivo

  2. Beyond axial symmetry: An improved class of models for global data

    KAUST Repository

    Castruccio, Stefano

    2014-03-01

    An important class of models for data on a spherical domain, called axially symmetric, assumes stationarity across longitudes but not across latitudes. The main aim of this work is to introduce a new and more flexible class of models by relaxing the assumption of longitudinal stationarity in the context of regularly gridded climate model output. In this investigation, two other related topics are discussed: the lack of fit of an axially symmetric parametric model compared with a non-parametric model and to longitudinally reversible processes, an important subclass of axially symmetric models.

  3. Beyond axial symmetry: An improved class of models for global data

    KAUST Repository

    Castruccio, Stefano; Genton, Marc G.

    2014-01-01

    An important class of models for data on a spherical domain, called axially symmetric, assumes stationarity across longitudes but not across latitudes. The main aim of this work is to introduce a new and more flexible class of models by relaxing the assumption of longitudinal stationarity in the context of regularly gridded climate model output. In this investigation, two other related topics are discussed: the lack of fit of an axially symmetric parametric model compared with a non-parametric model and to longitudinally reversible processes, an important subclass of axially symmetric models.

  4. Differential diagnosis of extra-axial intracranial tumours by dynamic spin-echo MRI

    International Nuclear Information System (INIS)

    Joo, Y.G.; Korogi, Y.; Hirai, T.; Sakamoto, Y.; Sumi, M.; Takahashi, M.; Ushio, Y.

    1995-01-01

    Dynamic MRI was performed on 22 patients with extra-axial intracranial tumours. Serial images were obtained every 30 s for 3 min using a spin-echo sequence (TR 200, TE 15 ms) after rapid injection of Gd-DTPA, 0.1 mmol/kg body weight. The contrast medium enhancement ratio (CER) was correlated with the histology of the tumours. Meningiomas and extra-axial metastases showed a sharp rise, then a gradual decline. Although both had a definite early peak of CER, metastases showed a more rapid decline. Neuromas and extra-axial lymphoma showed a slow, steady increase with no peak within 180 s. This study indicates that the CER is helpful in the differentiation of extra-axial tumours. (orig.)

  5. Characterisation of plasmas produced by the "Torche a Injection Axiale"

    NARCIS (Netherlands)

    Jonkers, J.; Selen, L.J.M.; Mullen, van der J.J.A.M.; Regt, de J.M.; Timmermans, E.A.H.; Schram, D.C.

    1996-01-01

    Summary form only given. The Torche a Injection Axiale (TIA), i.e. torch with axial gas injection, was developed by the group of Moisan in 1993. We report on the investigations on two different kind of plasmas created by the TIA: one with helium and the other with argon as main gas. Using absolute

  6. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  7. Non-steroidal anti-inflammatory drugs (NSAIDs) for axial spondyloarthritis (ankylosing spondylitis and non-radiographic axial spondyloarthritis)

    NARCIS (Netherlands)

    Kroon, Feline P. B.; van der Burg, Lennart R. A.; Ramiro, Sofia; Landewé, Robert B. M.; Buchbinder, Rachelle; Falzon, Louise; van der Heijde, Désirée

    2015-01-01

    Axial spondyloarthritis (axSpA) comprises ankylosing spondylitis (radiographic axSpA) and non-radiographic (nr-)axSpA and is associated with psoriasis, uveitis and inflammatory bowel disease. Non-steroidal anti-inflammatory drugs (NSAIDs) are recommended as first-line drug treatment. To determine

  8. Axial blanket enrichment optimization of the NPP Krsko fuel

    International Nuclear Information System (INIS)

    Kromar, M.; Kurincic, B.

    2001-01-01

    In this paper optimal axial blanket enrichment of the NPP Krsko fuel is investigated. Since the optimization is dictated by economic categories that can significantly vary in time, two step approach is applied. In the first step simple relationship between the equivalent change in enrichment of axial blankets and central fuel region is established. The relationship is afterwards processed with economic criteria and constraints to obtain optimal axial blanket enrichment. In the analysis realistic NPP Krsko conditions are considered. Except for the fuel enrichment all other fuel characteristics are the same as in the fuel used in the few most recent cycles. A typical reload cycle after the plant power uprate is examined. Analysis has shown that the current blanket enrichment is close to the optimal. Blanket enrichment reduction results in an approximately 100 000 US$ savings per fuel cycle.(author)

  9. Diagnosis of blow-out fracture of the orbital floor using a computed tomography

    International Nuclear Information System (INIS)

    Ishikawa, Yoshimi; Aoki, Shinjiroh; Ono, Shigeru; Fujita, Kiyohide

    1986-01-01

    Diagnosis of a blow-out fracture of the orbital floor is relatively easy from clinical and roentogen findings but information from these findings are not adequate for the decision for surgical indication. Until recently, computed tomography for the orbital region was generally performed only in axial plane. But the axial plane is parallel to the orbital structure, therefore it is difficult to visualize the orbital floor and inferior rectus muscle. On the other hand, coronal plane is cross-section to the orbital structure, and we can visualize the all orbital soft tissues including extraocular muscles. We examined 3 cases diagnosed as a blow-out fracture of the orbital floor by conventional roentogen films and clinical findings. After axial CT was performed firstly, the coronal CT was scanned with 60 degrees to 70 degrees from OM line, setting the patient in the hanging head position. Case 1 used coronal reformation of the axial CT data. Case 2 and case 3 used direct coronal scanning. By bi-plane CT we could diagnose whether inferior rectus muscle was entrapped or not, and confirm surgical indication. Using of a cadaver, we studied the mechanism for limitation of eye movement. These studies revealed that it is rare that the inferior rectus muscle is entrapped directly by fractured segments at the orbital anterior floor. Because there is a lot of orbital fat-pad between the inferior rectus muscle and the orbital floor, and it may play an important role. The limited mobility of the inferior rectus muscle may occur as a result of increased tension of the fibrous bands that attach to the muscle sheath from the prolapsed fat-pad, and contructure by scar formed secondarily. Diagnosis of the location of a fracture in the orbital floor and cause of the limitation of eye movement must be done as early as possible and from this information we can confirm surgical indication. (J.P.N.)

  10. Ventajas de los motores de flujo axial

    Directory of Open Access Journals (Sweden)

    Alberto M Basanta Otero

    2011-03-01

    Full Text Available Es importante conocer sobre una familia de motores que a diferencia de los convencionales o tradicionales no presentanun flujo rotatorio radial, denominados motores de flujo axial. Dichos motores presentan altos valores de par motriz abajas velocidades, una alta eficiencia y alta densidad de potencia. Este trabajo constituye un breve análisis dealgunos motores de la referencia bibliográfica.  Is important to know about a family of motors that at difference whit the traditional, don't have a rotator radial flux,called, axial flux motors. These motors have high torque for low speed, high efficiency and high power density. Thiswork is a brief analysis of several motors of the bibliographic references.

  11. Assessment of simulated mandibular condyle bone lesions by cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Alexandre Perez; Perrella, Andreia; Arita, Emiko Saito; Pereira, Marlene Fenyo Soeiro de Matos; Cavalcanti, Marcelo de Gusmao Paraiso, E-mail: alexperez34@gmail.co [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Odontologia. Dept. de Estomatologia

    2010-10-15

    There are many limitations to image acquisition, using conventional radiography, of the temporomandibular joint (TMJ) region. The Computed Tomography (CT) scan is a better option, due to its higher accuracy, for purposes of diagnosis, surgical planning and treatment of bone injuries. The aim of the present study was to analyze two protocols of cone beam computed tomography for the evaluation of simulated mandibular condyle bone lesions. Spherical lesions were simulated in 30 dry mandibular condyles, using dentist drills and drill bits sizes 1, 3 and 6. Each of the mandibular condyles was submitted to cone beam computed tomography (CBCT) using two protocols: axial, coronal and sagittal multiplanar reconstruction (MPR); and sagittal plus coronal slices throughout the longitudinal axis of the mandibular condyles. For these protocols, 2 observers analyzed the CBCT images independently, regarding the presence or not of injuries. Only one of the observers, however, performed on 2 different occasions. The results were compared to the gold standard, evaluating the percentage of agreement, degree of accuracy of CBCT protocols and observers' examination. The z test was used for the statistical analysis. The results showed there were no statistically significant differences between the 2 protocols. There was greater difficulty in the assessment of small-size simulated lesions (drill no.1). From the results of this study, it can be concluded that CBCT is an accurate tool for analyzing mandibular condyle bone lesions, with the MPR protocol showing slightly better results than the sagittal plus coronal slices throughout the longitudinal axis. (author)

  12. Evaluation of myocardial involvement in muscular dystrophy with Thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Yamamoto, S.; Kawai, N.; Matsushima, H.; Okada, M.; Yamauchi, K.; Yokota, M.; Hayashi, H.; Sotobata, I.; Sakuma, S.

    1985-01-01

    The clinical usefulness of quantitative analysis of thallium-201 emission computed tomography (ECT) for evaluation of left ventricular myocardial fibrosis was assessed on 45 patients with Duchenne(D), facioscapulohumeral(FSH), limbgirdle(LG) and myotonic(M) dystrophy. Trans-,long- and short-axial images were interpreted quantitatively using circumferential profile analysis, and the fibrotic tissue size (%FIB) was estimated by integration of hypoperfused areas in 6 to 8 consecutive short-axial slices. Lung/mediastinum count ratios (L/M ratio) were also assessed. Distinct ECT defects were found in 42 patients (all cases of D, FSH and LG, and 2 of 5 MTs). ECT defects were observed specifically in the posterolateral wall (71%) and apex (58%) in D, and were scattered in all LV walls in FSHG, LG and MT. ECG and VCG underestimated the extent of myocardial fibrosis in 17 patients (40%). Percent FIBs coincided with fibrotic tissue sizes proven by autopsy. Body-surface ECG should be influenced by cardiac position and rotation in the thorax, which were often observed in these disease entities. These factors were also assessed with ECT. The authors conclude; ECT to be useful for non-invasive evaluation of myocardial fibrosis in patients with various types of muscular dystrophy

  13. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  14. Evaluation of myocardial involvement in muscular dystrophy with thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Sotobata, Iwao; Indo, Toshikatsu; Matsuoka, Yukihiko; Kawai, Naoki; Matsushima, Hideo; Suzuki, Akio; Abe, Tetsutaro; Sakuma, Sadayuki

    1986-01-01

    The clinical usefulness of thallium-201 myocardial perfusion scanning with emission computed tomography (ECT) for evaluation of left ventricular myocardial fibrosis was assessed on 47 patients with Duchenne (DMD), facioscapulohumeral (FSH), limb-girdle (LG) and myotonic (MT) dystrophy. Trans-, long- and short-axial images were interpreted quantitatively by circumferential profile analysis, and the fibrotic tissue size (%FIB) was estimated by integration of hypoperfused areas in 6 to 8 consecutive short-axial slices. Lung/mediastinum count ratios (L/M ratio), LV cavity dilatation, aneurysm formation and cardiac malrotations were also assessed with ECT. Distinct ECT perfusion defect was observed in 26 of 29 DMDs, and in 11 of 18 patients with other types. Perfusion defect was demonstrated in 95 of total 235 segments, and was observed specifically in the posterior wall (82 %) and the apex (65 %) in DMD, and was scattered in all LV wall segments in FSH, LG, and MT. Percent FIB correlated significantly with L/M ratio (r = 0.82, p < 0.01), and did not with age or clinical stage score. ECT showed marked LV dilatation in 7, apical aneurysm in 5 and cardiac malrotation in 23 of the 47 patients. In conclusion, ECT was considered to be a useful clinical means of evaluating myocardial involvement in patients with muscular dystrophy. (author)

  15. A multi-channel magnetic induction tomography measurement system for human brain model imaging

    International Nuclear Information System (INIS)

    Xu, Zheng; Luo, Haijun; He, Wei; He, Chuanhong; Song, Xiaodong; Zahng, Zhanglong

    2009-01-01

    This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in a human brain model. A hemispherical glass bowl filled with a salt solution is used as the human brain model; meanwhile, agar blocks of different conductivity are placed in the solution to simulate the intracerebral hemorrhage. The excitation and detection coils are fixed co-axially, and the axial gradiometer is used as the detection coil in order to cancel the primary field. On the outer surface of the glass bowl, 15 sensor units are arrayed in two circles as measurement parts, and a single sensor unit for canceling the phase drift is placed beside the glass bowl. The phase sensitivity of our system is 0.204°/S m −1 with the excitation frequency of 120 kHz and the phase noise is in the range of −0.03° to +0.05°. Only the coaxial detection coil is available for each excitation coil; therefore, 15 phase data are collected in each measurement turn. Finally, the two-dimensional images of conductivity distribution are obtained using an interpolation algorithm. The frequency-varying experiment indicates that the imaging quality becomes better as the excitation frequency is increased

  16. Golimumab for the treatment of axial spondyloarthritis.

    Science.gov (United States)

    Palazzi, Carlo; D'angelo, Salvatore; Gilio, Michele; Leccese, Pietro; Padula, Angela; Olivieri, Ignazio

    2017-01-01

    Anti-TNF drugs have represented an epochal revolution in the treatment of rheumatoid arthritis and spondyloarthritis. In the field of axial spondyloarthritis, golimumab, a fully human monoclonal anti-TNFα administered subcutaneously every 4 weeks, has shown significant efficacy and good safety in patients with ankylosing spondylitis. More recently, it was also indicated as an effective treatment for patients suffering from non-radiographic axial spondyloarthitits. Areas covered: A systematic literature search was completed, using the largest electronic databases (Medline, Embase and Cochrane), with the aim to review all data concerning the administration of golimumab in patients suffering from axial spondyloartritis. Expert opinion: In the 16-week GO-AHEAD study, golimumab was effective in patients with non-radiographic spondyloarthritis with high levels of CRP and/or positive MRI findings, but not in subjects with both negative CRP and MRI. This finding allows for the addressing the of anti-TNF treatment more specifically. Preliminary data concerning an open-label extension of the GO-AHEAD study outlined the high retention-rate of the drug at 52 weeks. The production of antibodies against golimumab is rare and it seems to exert scarce influence on the drug performances. In conclusion, golimumab appears as a very useful and well tolerated anti-TNF agent.

  17. Passive axial magnetic bearing with Halbach magnetized array in magnetically suspended control moment gyro application

    International Nuclear Information System (INIS)

    Sun Jinji; Ren Yuan; Fang Jiancheng

    2011-01-01

    The paper presents a special configuration of passive axial magnetic bearing with segmented Halbach magnetized array in magnetically suspended control moment gyro (MSCMG). Peculiarity of presented passive axial magnetic bearing is its ability to provide angular stiffness so that it can produce gyro moment when it is used in MSCMG. The MSCMG with this passive axial magnetic bearing can efficiently reduce the power loss when it supplies gyro moment compared with the five degrees of freedom (5-DOF) MSCMG. The characteristics of the suspension force and stiffness of the passive axial magnetic bearing are studied using finite element method (FEM). The performance of the presented passive axial magnetic bearing with Halbach magnetized array is verified by a prototyped MSCMG. - Research highlights: → Passive axial magnetic bearing is used to provide angular stiffness. → Passive axial magnetic bearing is based on repulsion. → Layers Halbach magnetized array realizes higher stiffness per bearing volume. → Passive axial magnetic bearing can provide gyro moment in CMG. → Power loss of MSCMG with PMB does not increase when it provides gyro moment.

  18. Clinical characteristics of importance to outcome in patients with axial spondyloarthritis

    DEFF Research Database (Denmark)

    Andreasen, Rikke Asmussen; Kristensen, Lars Erik; Ellingsen, Torkell

    2017-01-01

    INTRODUCTION: Spondyloarthritis (SpA) is a heterogeneous spectrum of rheumatic diseases with either predominantly axial inflammatory symptoms of the spine and sacroiliac joints or predominantly peripheral arthritis. The two main entities of axial SpA (axSpA) are ankylosing spondylitis or non...

  19. Guided wave propagation as a measure of axial loads in rails

    CSIR Research Space (South Africa)

    Loveday, PW

    2010-03-01

    Full Text Available Guided wave propagation has been proposed as a means to monitor the axial loads in continuously welded railway rails although no practical system has been developed. In this paper, the influence of axial load on the guided wave propagation...

  20. Posterior atlanto-occipital and atlanto-axial area and its surgical interest

    Directory of Open Access Journals (Sweden)

    Newton José Godoy Pimenta

    2014-10-01

    Full Text Available Classic anatomical studies describe two membranes – atlanto-occipital and atlanto-axial in the posterior aspect of the craniocervical region. During many surgical procedures in this area, however, we have not found such membranes. Objective To clarify the anatomical aspects and structures taking part of the posterior atlanto-occipital and atlanto-axial area. Method Analysis of histological cuts of three human fetuses and anatomical studies of 8 adult human cadavers. Results In both atlanto-occipital and atlanto-axial areas, we have observed attachment between suboccipital deep muscles and the spinal cervical dura. However, anatomical description of such attachments could not be found in textbooks of anatomy. Conclusion Our study shows the absence of the classical atlanto-occipital and atlanto-axial membranes; the occipito-C1 and C1-C2 posterior intervals are an open area, allowing aponeurotic attachment among cervical dura mater and posterior cervical muscles.

  1. Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking.

    Science.gov (United States)

    Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J; Jian, Yifan; Sarunic, Marinko V

    2016-02-01

    High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.

  2. Amphiregulin Antibody and Reduction of Axial Elongation in Experimental Myopia

    Directory of Open Access Journals (Sweden)

    Wen Jun Jiang

    2017-03-01

    Full Text Available To examine the mechanism of ocular axial elongation in myopia, guinea pigs (age: 2–3 weeks which either underwent unilateral or bilateral lens-induced myopization (group 1 or which were primarily myopic at baseline (group 2 received unilateral intraocular injections of amphiregulin antibody (doses: 5, 10, or 15 μg three times in intervals of 9 days. A third group of emmetropic guinea pigs got intraocular unilateral injections of amphiregulin (doses: 0.25, 0.50 or 1.00 ng, respectively. In each group, the contralateral eyes received intraocular injections of Ringer's solution. In intra-animal inter-eye comparison and intra-eye follow-up comparison in groups 1 and 2, the study eyes as compared to the contralateral eyes showed a dose-dependent reduction in axial elongation. In group 3, study eyes and control eyes did not differ significantly in axial elongation. Immunohistochemistry revealed amphiregulin labelling at the retinal pigment epithelium in eyes with lens-induced myopization and Ringer's solution injection, but not in eyes with amphiregulin antibody injection. Intraocular injections of amphiregulin-antibody led to a reduction of lens-induced axial myopic elongation and of the physiological eye enlargement in young guinea pigs. In contrast, intraocularly injected amphiregulin in a dose of ≤1 ng did not show a significant effect. Amphiregulin may be one of several essential molecular factors for axial elongation.

  3. A note on axial symmetries

    International Nuclear Information System (INIS)

    Beetle, Christopher; Wilder, Shawn

    2015-01-01

    This note describes how to characterize and normalize an axial Killing field on a general Riemannian geometry or four-dimensional Lorentzian geometry. No global assumptions are necessary, such as that the orbits of the Killing field all have period 2π. Rather, any Killing field that vanishes at at least one point necessarily has the expected global properties. (note)

  4. Experimental Investigation of the Root Cause Mechanism and Effectiveness of Mitigating Actions for Axial Offset Anomaly in Pressurized Water Reactors

    International Nuclear Information System (INIS)

    Said Abdel-Khalik

    2005-01-01

    Axial offset anomaly (AOA) in pressurized water reactors refers to the presence of a significantly larger measured negative axial offset deviation than predicted by core design calculations. The neutron flux depression in the upper half of high-power rods experiencing significant subcooled boiling is believed to be caused by the concentration of boron species within the crud layer formed on the cladding surface. Recent investigations of the root-cause mechanism for AOA [1,2] suggest that boron build-up on the fuel is caused by precipitation of lithium metaborate (LiBO2) within the crud in regions of subcooled boiling. Indirect evidence in support of this hypothesis was inferred from operating experience at Callaway, where lithium return and hide-out were, respectively, observed following power reductions and power increases when AOA was present. However, direct evidence of lithium metaborate precipitation within the crud has, heretofore, not been shown because of its retrograde solubility. To this end, this investigation has been undertaken in order to directly verify or refute the proposed root-cause mechanism of AOA, and examine the effectiveness of possible mitigating actions to limit its impact in high power PWR cores

  5. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    Directory of Open Access Journals (Sweden)

    Talita Zerbini

    2014-12-01

    Full Text Available Objective: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. Method: Comparison between the findings of different methods: autopsy and postmortem computed tomography. Results: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. Conclusions: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations.

  6. [Diagnostic significance of multi-slice computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Liu, Fang; Tian, Zhi-Liang; Lei, Zi-Qiao; Li, You-Lin; Kong, Wei-Jia

    2005-04-01

    To evaluate the feasibility and usability of multi-slice computed tomography (MSCT) in congenital inner ear malformations. Fourty-four patients with sensorineural hearing loss (SNHL) were examined by a Somatom Sensation 16 (siemens, Germany) CT scanner with following parameters: 120 kV, 100 mAs, 0.75 mm collimation, 1 mm reconstruction increment, a pitch factor of 1 and a field of view of 100 mm. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment, and a field of view of 50 mm. The 3D reconstructions were done with volume rendering technique (VRT) on the workstation (3D Virtuoso and Wizard,siemens). Twenty-five patients were normal and 19 patients (36 ears) were congenital inner ear malformations among 44 patients scanned with MSCT. Of the malformations, all the axial, MPR and VRT images can display the site and degree in 33 ears. VRT images were superior to the axial images in displaying the malformations in 3 ears with the small lateral semicircular canal malformations. The malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity, 5 ears), vestibular and semicircular canal malformations( 14 ears), vestibular aqueduct dilate( 16 ears, of which 6 ears accompanied by other malformations), the internal auditory canal malformation(8 ears, all accompanied by other malformations). MSCT allows a comprehensively assessing various congenital ear malformations through high quality MPR and VRT reconstructions. VRT images can display the site and degree of the malformations three-dimensionally and intuitionisticly. It is very useful to the cochlear implantation.

  7. Axial power deviation control strategy and computer simulation for Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Liao Yehong; Zhou Xiaoling, Xiao Min

    2004-01-01

    Daya Bay Nuclear Power Station has very tight operation diagram especially at its right side. Therefore the successful control of axial power deviation for PWR is crucial to nuclear safety. After analyzing various core characters' effect on axial power distribution, several axial power deviation control strategies has been proposed to comply with different power varying operation scenario. Application and computer simulation of the strategies has shown that our prediction of axial power deviation evolution are comparable to the measurement values, and that our control strategies are effective. Engineering experience shows that the application of our methodology can predict accurately the transient of axial power deviation, and therefore has become a useful tool for reactor operation and safety control. This paper presents the axial power control characteristics, reactor operation strategy research, computer simulation, and comparison to measurement results in Daya Bay Nuclear Power Station. (author)

  8. Theorem on axially symmetric gravitational vacuum configurations

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulos, A; Le Denmat, G [Paris-6 Univ., 75 (France). Inst. Henri Poincare

    1977-01-24

    A theorem is proved which asserts the non-existence of axially symmetric gravitational vacuum configurations with non-stationary rotation only. The eventual consequences in black-hole physics are suggested.

  9. Tunable axial gauge fields in engineered Weyl semimetals: semiclassical analysis and optical lattice implementations

    Science.gov (United States)

    Roy, Sthitadhi; Kolodrubetz, Michael; Goldman, Nathan; Grushin, Adolfo G.

    2018-04-01

    In this work, we describe a toolbox to realize and probe synthetic axial gauge fields in engineered Weyl semimetals. These synthetic electromagnetic fields, which are sensitive to the chirality associated with Weyl nodes, emerge due to spatially and temporally dependent shifts of the corresponding Weyl momenta. First, we introduce two realistic models, inspired by recent cold-atom developments, which are particularly suitable for the exploration of these synthetic axial gauge fields. Second, we describe how to realize and measure the effects of such axial fields through center-of-mass observables, based on semiclassical equations of motion and exact numerical simulations. In particular, we suggest realistic protocols to reveal an axial Hall response due to the axial electric field \

  10. Axial-Centrifugal Compressor Program

    Science.gov (United States)

    1975-10-01

    Assembly . .. . .... ..... 33 5 Tie Bolt...... .. .. .. .. . *.. .. .. .. .. .. ... 34 6 Axial Compressor Rotor Assembly Runouts . . .. . 34 7 CCV Blow...1.796 Impeller Slip Factor ’Ce2/U 2 ) .91 Impeller Wheel Speed ft/sec 1992.2 Impellet ’.ip Radius in. 3.780 Blade Tip Metal Angle- deg 0 Numbec of Blades...test item to the next Phase V component test. The test vehicle final balance levels and rotor runouts were normal at teardown, and no rubsI were

  11. Improvement of axial power distribution synthesis methodology in CPC

    International Nuclear Information System (INIS)

    Kim, H. H.; Gee, S. G.;; Kim, Y. B.; In, W. K.

    2003-01-01

    The capability of axial power distribution synthesis in CPC plays an important role in determining the DNBR and LPD trip caused by CPC. The axial power distribution is synthesized using the cubic spline function based on the three excore detector signals. The axial power distributions are categorized into 8 function sets and each sets are stored as pre-calculated values in CPC to save the calculation time. In this study, the additional function sets, the real break-point function sets and the polynomial function are suggested to evaluate the possibility of improving the synthesis capability in CPC. In addition, RMS errors are compared and evaluated for each synthesis method. As a result, it was confirmed that the function sets stored in CPC were not optimal. The analysis result showed that RMS error could be reduced by selecting the proper function sets suggested in this study

  12. Constitutive relations describing creep deformation for multi-axial time-dependent stress states

    Science.gov (United States)

    McCartney, L. N.

    1981-02-01

    A THEORY of primary and secondary creep deformation in metals is presented, which is based upon the concept of tensor internal state variables and the principles of continuum mechanics and thermodynamics. The theory is able to account for both multi-axial and time-dependent stress and strain states. The wellknown concepts of elastic, anelastic and plastic strains follow naturally from the theory. Homogeneous stress states are considered in detail and a simplified theory is derived by linearizing with respect to the internal state variables. It is demonstrated that the model can be developed in such a way that multi-axial constant-stress creep data can be presented as a single relationship between an equivalent stress and an equivalent strain. It is shown how the theory may be used to describe the multi-axial deformation of metals which are subjected to constant stress states. The multi-axial strain response to a general cyclic stress state is calculated. For uni-axial stress states, square-wave loading and a thermal fatigue stress cycle are analysed.

  13. Design, Test, and Evaluation of a Transonic Axial Compressor Rotor with Splitter Blades

    Science.gov (United States)

    2013-09-01

    INTRODUCTION A. MOTIVATION Over the course of turbomachinery history splitter vanes have been used extensively in centrifugal compressors . Axial...TEST, AND EVALUATION OF A TRANSONIC AXIAL COMPRESSOR ROTOR WITH SPLITTER BLADES by Scott Drayton September 2013 Dissertation Co...AXIAL COMPRESSOR ROTOR WITH SPLITTER BLADES 5. FUNDING NUMBERS 6. AUTHOR(S) Scott Drayton 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES

  14. Spectral analysis in thin tubes with axial heterogeneities

    KAUST Repository

    Ferreira, Rita; Mascarenhas, M. Luí sa; Piatnitski, Andrey

    2015-01-01

    In this paper, we present the 3D-1D asymptotic analysis of the Dirichlet spectral problem associated with an elliptic operator with axial periodic heterogeneities. We extend to the 3D-1D case previous 3D-2D results (see [10]) and we analyze the special case where the scale of thickness is much smaller than the scale of the heterogeneities and the planar coefficient has a unique global minimum in the periodic cell. These results are of great relevance in the comprehension of the wave propagation in nanowires showing axial heterogeneities (see [17]).

  15. Rotating stall simulation for axial and centrifugal compressors

    Science.gov (United States)

    Halawa, Taher; Gadala, Mohamed S.

    2017-05-01

    This study presents a numerical simulation of the rotating stall phenomenon in axial and centrifugal compressors with detailed descriptions of stall precursors and its development with time. Results showed that the vaneless region of the centrifugal compressor is the most critical location affected by stall. It was found that the tip leakage flow and the back flow impingement are the main cause of the stall development at the impeller exit area for centrifugal compressors. The results of the axial compressor simulations indicated that the early separated flow combined with the tip leakage flow can block the impeller passages during stall.

  16. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  17. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    International Nuclear Information System (INIS)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E.

    1990-01-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas

  18. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  19. Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma

    Directory of Open Access Journals (Sweden)

    Dewang Angmo

    2016-01-01

    Full Text Available Optical coherence tomography (OCT, a noninvasive imaging modality that uses low-coherence light to obtain a high-resolution cross-section of biological structures, has evolved dramatically over the years. The Swept-source OCT (SS-OCT makes use of a single detector with a rapidly tunable laser as a light source. The Casia SS-1000 OCT is a Fourier-domain, SS-OCT designed specifically for imaging the anterior segment. This system achieves high resolution imaging of 10΅m (Axial and 30΅m (Transverse and high speed scanning of 30,000 A-scans per second. With a substantial improvement in scan speed, the anterior chamber angles can be imaged 360 degrees in 128 cross sections (each with 512 A-scans in about 2.4 seconds. We summarize the clinical applications of anterior segment SS-OCT in Glaucoma. Literature search: We searched PubMed and included Medline using the phrases anterior segment optical coherence tomography in ophthalmology, swept-source OCT, use of AS-OCT in glaucoma, use of swept-source AS-OCT in glaucoma, quantitative assessment of angle, filtering bleb in AS-OCT, comparison of AS-OCT with gonioscopy and comparison of AS-OCT with UBM. Search was made for articles dating 1990 to August 2015.

  20. Interconnection between several eye biomechanical and biometric parameters in children with axial and refractive mild myopia

    Directory of Open Access Journals (Sweden)

    T. Ye. Tsybulskaya

    2016-08-01

    Full Text Available Aim – to study the relationship of biometric and biomechanical indicators of corneoscleral capsule of the eye in children with axial and refractive mild myopia. Materials and methods. Axial myopia was diagnosed in 32 children (64 eyes, refractive myopia – 18 (36 eyes. The control group – 16 children without ophthalmic diseases (32 eyes. Eye examination: visometry, automated refractometry, biomicroscopy, ophthalmoscopy, determination of the axial length of the eyeball and corneal hysteresis. Results. Significant differences were determined in the indicators of dioptric power of the cornea: 42.2 dpt in patients with axial and 44.7 dpt with refractive myopia (p<0.05, and also difference between patients with refractive myopia and the control group, in which the diopter power of cornea was 42.6 (p<0.05. There are also significant differences in the indicators of the axial length of eyes between axial and refractive myopia – 24.5±0.64 mm and 23.1±0.43 mm (p<0.05. Significant difference with the control group in the axial length marked only in eyes with axial myopia 22.7±0.33 mm and 24.5±0.64 mm, respectively (p<0.05. Corneal hysteresis determined significantly reduced on eyes with both the axial and refractive myopia, which was significantly lower than in the indicators of emmetropic eyes of the control group 13.7 (p<0.05. Corneal hysteresis is inversely related to the axial length of the eyeball: in patients with axial myopia r -0.32, p<0.05; with refractive myopia r -0.36, p<0.05. Сorrelation between diopter power of cornea and axial length of the eyeball: r -0.53, р<0.05 in eyes with axial myopia and r -0.42, p<0.05 refractive myopia. Comparative analysis showed no significant differences between the corneal hysteresis, the axial length of the eye and the spherical component of myopia. Conclusions. In patients with axial and refractive mild myopia corneal hysteresis is reduced on average in 1.2 and 1.1 times, in comparison with

  1. Breast tumor classification using axial shear strain elastography: a feasibility study

    International Nuclear Information System (INIS)

    Thitaikumar, Arun; Ophir, Jonathan; Mobbs, Louise M; Kraemer-Chant, Christina M; Garra, Brian S

    2008-01-01

    Recently, the feasibility of visualizing the characteristics of bonding at an inclusion-background boundary using axial-shear strain elastography was demonstrated. In this paper, we report a feasibility study on the utility of the axial-shear strain elastograms in the classification of in vivo breast tumor as being benign or malignant. The study was performed using data sets obtained from 15 benign and 15 malignant cases that were biopsy proven. A total of three independent observers were trained, and their services were utilized for the study. A total of 9 cases were used as training set and the remaining cases were used as testing set. The feature from the axial-shear strain elastogram, namely, the area of the axial-shear region, was extracted by the observers. The observers also outlined the tumor area on the corresponding sonogram, which was used to normalize the area of the axial-shear strain region. There are several observations that can be drawn from the results. First, the result indicates that the observers consistently (∼82% of the cases) noticed the characteristic pattern of the axial-shear strain distribution data as predicted in the previous simulation studies, i.e. alternating regions of positive and negative axial-shear strain values around the tumor-background interface. Second, the analysis of the result suggests that in approximately 57% of the cases in which the observers did not visualize tumor in the sonogram, the elastograms helped them to locate the tumor. Finally, the analysis of the result suggests that for the discriminant feature value of 0.46, the number of unnecessary biopsies could be reduced by 56.3% without compromising on sensitivity and on negative predictive value (NPV). Based on the results in this study, feature values greater than 0.75 appear to be indicative of malignancy, while values less than 0.46 to be indicative of benignity. Feature values between 0.46 and 0.75 may result in an overlap between benign and malignant

  2. Utility of axial images in an early Alzheimer disease diagnosis support system (VSRAD)

    International Nuclear Information System (INIS)

    Goto, Masami; Aoki, Shigeki; Abe, Osamu

    2006-01-01

    In recent years, voxel-based morphometry (VBM) has become a popular tool for the early diagnosis of Alzheimer disease. The Voxel-Based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), a VBM system that uses MRI, has been reported to be clinically useful. The able-bodied person database (DB) of VSRAD, which employs sagittal plane imaging, is not suitable for analysis by axial plane imaging. However, axial plane imaging is useful for avoiding motion artifacts from the eyeball. Therefore, we created an able-bodied person DB by axial plane imaging and examined its utility. We also analyzed groups of able-bodied persons and persons with dementia by axial plane imaging and reviewed the validity. After using the DB of axial plane imaging, the Z-score of the intrahippocampal region improved by 8 in 13 instances. In all brains, the Z-score improved by 13 in all instances. (author)

  3. [Utility of axial images in an early Alzheimer disease diagnosis support system (VSRAD)].

    Science.gov (United States)

    Goto, Masami; Aoki, Shigeki; Abe, Osamu; Masumoto, Tomohiko; Watanabe, Yasushi; Satake, Yoshiroh; Nishida, Katsuji; Ino, Kenji; Yano, Keiichi; Iida, Kyohhito; Mima, Kazuo; Ohtomo, Kuni

    2006-09-20

    In recent years, voxel-based morphometry (VBM) has become a popular tool for the early diagnosis of Alzheimer disease. The Voxel-Based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), a VBM system that uses MRI, has been reported to be clinically useful. The able-bodied person database (DB) of VSRAD, which employs sagittal plane imaging, is not suitable for analysis by axial plane imaging. However, axial plane imaging is useful for avoiding motion artifacts from the eyeball. Therefore, we created an able-bodied person DB by axial plane imaging and examined its utility. We also analyzed groups of able-bodied persons and persons with dementia by axial plane imaging and reviewed the validity. After using the DB of axial plane imaging, the Z-score of the intrahippocampal region improved by 8 in 13 instances. In all brains, the Z-score improved by 13 in all instances.

  4. Aryabhala and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 3. Aryabhata and Axial Rotation of Earth - Khagola (The Celestial Sphere). Amartya Kumar Dutta. General Article Volume 11 Issue 3 March 2006 pp 51-68. Fulltext. Click here to view fulltext PDF. Permanent link:

  5. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  6. Axial Ge/Si nanowire heterostructure tunnel FETs.

    Energy Technology Data Exchange (ETDEWEB)

    Dayeh, Shadi A. (Los Alamos National Laboratory); Gin, Aaron V.; Huang, Jian Yu; Picraux, Samuel Thomas (Los Alamos National Laboratory)

    2010-03-01

    Axial Ge/Si heterostructure nanowires (NWs) allow energy band-edge engineering along the axis of the NW, which is the charge transport direction, and the realization of asymmetric devices for novel device architectures. This work reports on two significant advances in the area of heterostructure NWs and tunnel FETs: (i) the realization of 100% compositionally modulated Si/Ge axial heterostructure NWs with lengths suitable for device fabrication and (ii) the design and implementation of Schottky barrier tunnel FETs on these NWs for high-on currents and suppressed ambipolar behavior. Initial prototype devices with 10 nm PECVD SiN{sub x} gate dielectric resulted in a very high current drive in excess of 100 {micro}A/{micro}m (I/{pi}D) and 10{sup 5} I{sub on}/I{sub off} ratios. Prior work on the synthesis of Ge/Si axial NW heterostructures through the VLS mechanism have resulted in axial Si/Si{sub 1-x}Ge{sub x} NW heterostructures with x{sub max} {approx} 0.3, and more recently 100% composition modulation was achieved with a solid growth catalyst. In this latter case, the thickness of the heterostructure cannot exceed few atomic layers due to the slow axial growth rate and concurrent radial deposition on the NW sidewalls leading to a mixture of axial and radial deposition, which imposes a big challenge for fabricating useful devices form these NWs in the near future. Here, we report the VLS growth of 100% doping and composition modulated axial Ge/Si heterostructure NWs with lengths appropriate for device fabrication by devising a growth procedure that eliminates Au diffusion on the NW sidewalls and minimizes random kinking in the heterostructure NWs as deduced from detailed microscopy analysis. Fig. 1 a shows a cross-sectional SEM image of epitaxial Ge/Si axial NW heterostructures grown on a Ge(111) surface. The interface abruptness in these Ge/Si heterostructure NWs is of the order of the NW diameter. Some of these NWs develop a crystallographic kink that is {approx

  7. Geochemistry of axial seamount lavas: Magmatic relationship between the Cobb Hotspot and the Juan de Fuca Ridge

    Science.gov (United States)

    Rhodes, J. M.; Morgan, C.; Liias, R. A.

    1990-08-01

    Axial Seamount, located along the central portion of the Juan de Fuca Ridge axis and at the eastern end of the Cobb-Eickelberg Seamount Chain, is the current center of the Cobb Hotspot. The Axial Seamount lavas are transitional between N-type and E-type mid-ocean ridge basalt (MORB), characteristics that they share with lavas along the rest of the Juan de Fuca Ridge. There are, however, subtle, but distinct, differences between the seamount lavas and those of the adjoining ridge segments. These include higher Na2O, CaO, and Sr at a given MgO content and lower silica saturation in the seamount lavas as compared with the ridge lavas. Lava chemistry and bathymetry indicate that Axial Seamount is a discrete volcanic unit, with a more productive shallow magmatic plumbing system separate from the adjacent ridge segments. These high magma supply rates have sustained a continuously replenished, steady state magma reservoir that has erupted remarkably homogeneous lavas over a long time period. Despite this classic association of spreading center and hotspot volcanic activity, there is no evidence in the lavas for geochemical or isotopic enrichment typical of hotspot or mantle plume activity. The differences in composition between the Axial Seamount lavas and the Juan de Fuca Ridge lavas are attributed to melting processes rather than to any fundamental differences in their mantle source compositions. The higher magma production rates, higher Sr, and lower silica saturation in the seamount lavas relative to the ridge lavas are thought to be a consequence of melt initiation at greater depths. The melting column producing the seamount lavas is thought to be initiated in the stability field of spinel peridotite, whereas the ridge lavas are produced from a melting column initiated at shallower levels, possibly within or close to the stability field of plagioclase peridotite. Implicit in this interpretation is the conclusion that the Juan de Fuca Ridge lavas, and by analogy most

  8. Assessment of the impact of modeling axial compression on PET image reconstruction.

    Science.gov (United States)

    Belzunce, Martin A; Reader, Andrew J

    2017-10-01

    To comprehensively evaluate both the acceleration and image-quality impacts of axial compression and its degree of modeling in fully 3D PET image reconstruction. Despite being used since the very dawn of 3D PET reconstruction, there are still no extensive studies on the impact of axial compression and its degree of modeling during reconstruction on the end-point reconstructed image quality. In this work, an evaluation of the impact of axial compression on the image quality is performed by extensively simulating data with span values from 1 to 121. In addition, two methods for modeling the axial compression in the reconstruction were evaluated. The first method models the axial compression in the system matrix, while the second method uses an unmatched projector/backprojector, where the axial compression is modeled only in the forward projector. The different system matrices were analyzed by computing their singular values and the point response functions for small subregions of the FOV. The two methods were evaluated with simulated and real data for the Biograph mMR scanner. For the simulated data, the axial compression with span values lower than 7 did not show a decrease in the contrast of the reconstructed images. For span 11, the standard sinogram size of the mMR scanner, losses of contrast in the range of 5-10 percentage points were observed when measured for a hot lesion. For higher span values, the spatial resolution was degraded considerably. However, impressively, for all span values of 21 and lower, modeling the axial compression in the system matrix compensated for the spatial resolution degradation and obtained similar contrast values as the span 1 reconstructions. Such approaches have the same processing times as span 1 reconstructions, but they permit significant reduction in storage requirements for the fully 3D sinograms. For higher span values, the system has a large condition number and it is therefore difficult to recover accurately the higher

  9. Production of low axial energy spread ion beams with multicusp sources

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yung -Hee Y. [Univ. of California, Berkeley, CA (United States)

    1998-05-01

    Multicusp ion sources are capable of producing ions with low axial energy spread which are necessary in applications such as: ion projection lithography (IPL) and focused ion beams for the next generation lithographic tools and nuclear science experiments such as radioactive ion beam production. The axial ion energy spread for multicusp source is approximately 6 eV which is too large for IPL and radioactive ion beam applications. The addition of a magnetic filter which consists of a pair of permanent magnets to the multicusp source reduces the energy spread considerably. The reduction is due to the improvement in the uniformity of the axial plasma potential distribution in the discharge region. Axial ion energy spread of the filament driven ion source has been measured using three different techniques. In all cases, it was found to be less than 2 eV. Energy spread of the radio frequency (RF) driven source has also been explored, and it was found to be less than 3 eV with the proper RF-shielding. A new multicusp source configuration has been designed and constructed to further reduce the energy spread. To achieve a more uniform axial plasma potential distribution, a cylindrical magnetic filter has been designed and constructed for a 2-cm-diameter source. This new source configuration, the co-axial source, is new in its kind. The energy spread in this source has been measured to be a record low of 0.6 eV. Because of the novelty of this device, some plasma parameters inside the source have been studied. Langmuir probe has been used to measure the plasma potential, the electron temperature and the density distribution.

  10. Production of low axial energy spread ion beams with multicusp sources

    International Nuclear Information System (INIS)

    Lee, Y.H.Y.

    1998-05-01

    Multicusp ion sources are capable of producing ions with low axial energy spread which are necessary in applications such as: ion projection lithography (IPL) and focused ion beams for the next generation lithographic tools and nuclear science experiments such as radioactive ion beam production. The axial ion energy spread for multicusp source is approximately 6 eV which is too large for IPL and radioactive ion beam applications. The addition of a magnetic filter which consists of a pair of permanent magnets to the multicusp source reduces the energy spread considerably. The reduction is due to the improvement in the uniformity of the axial plasma potential distribution in the discharge region. Axial ion energy spread of the filament driven ion source has been measured using three different techniques. In all cases, it was found to be less than 2 eV. Energy spread of the radio frequency (RF) driven source has also been explored, and it was found to be less than 3 eV with the proper RF-shielding. A new multicusp source configuration has been designed and constructed to further reduce the energy spread. To achieve a more uniform axial plasma potential distribution, a cylindrical magnetic filter has been designed and constructed for a 2-cm-diameter source. This new source configuration, the co-axial source, is new in its kind. The energy spread in this source has been measured to be a record low of 0.6 eV. Because of the novelty of this device, some plasma parameters inside the source have been studied. Langmuir probe has been used to measure the plasma potential, the electron temperature and the density distribution

  11. Improved Patient Size Estimates for Accurate Dose Calculations in Abdomen Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang-Lae [Yonsei University, Wonju (Korea, Republic of)

    2017-07-15

    The radiation dose of CT (computed tomography) is generally represented by the CTDI (CT dose index). CTDI, however, does not accurately predict the actual patient doses for different human body sizes because it relies on a cylinder-shaped head (diameter : 16 cm) and body (diameter : 32 cm) phantom. The purpose of this study was to eliminate the drawbacks of the conventional CTDI and to provide more accurate radiation dose information. Projection radiographs were obtained from water cylinder phantoms of various sizes, and the sizes of the water cylinder phantoms were calculated and verified using attenuation profiles. The effective diameter was also calculated using the attenuation of the abdominal projection radiographs of 10 patients. When the results of the attenuation-based method and the geometry-based method shown were compared with the results of the reconstructed-axial-CT-image-based method, the effective diameter of the attenuation-based method was found to be similar to the effective diameter of the reconstructed-axial-CT-image-based method, with a difference of less than 3.8%, but the geometry-based method showed a difference of less than 11.4%. This paper proposes a new method of accurately computing the radiation dose of CT based on the patient sizes. This method computes and provides the exact patient dose before the CT scan, and can therefore be effectively used for imaging and dose control.

  12. Bifunctional organocatalysts for the asymmetric synthesis of axially chiral benzamides

    Directory of Open Access Journals (Sweden)

    Ryota Miyaji

    2017-08-01

    Full Text Available Bifunctional organocatalysts bearing amino and urea functional groups in a chiral molecular skeleton were applied to the enantioselective synthesis of axially chiral benzamides via aromatic electrophilic bromination. The results demonstrate the versatility of bifunctional organocatalysts for the enantioselective construction of axially chiral compounds. Moderate to good enantioselectivities were afforded with a range of benzamide substrates. Mechanistic investigations were also carried out.

  13. Positron Emission Tomography in Prostate Cancer: Summary of Systematic Reviews and Meta-Analysis.

    Science.gov (United States)

    Jadvar, Hossein

    2015-09-01

    Prostate cancer is a prevalent public health problem worldwide. Over the past decade, there has been tremendous research activity in the potential use of positron emission tomography with a number of radiotracers targeted to various biological aspects of this complex tumor. Systematic reviews and meta-analysis are important contributions to the relevant literature that summarize the evidence while reducing the effect of various sources of bias in the published data. The accumulation of relevant data in this clinical setting has recently provided the opportunity for systematic reviews. In this brief article, I summarize the published systematic reviews and meta-analysis of positron emission tomography in prostate cancer. Most robust evidence suggests a probable role for first-line use of positron emission tomography with radiolabeled choline in restating patients with biochemical relapse of prostate cancer with the diagnostic performance that appears to be positively associated with the serum prostate specific antigen level and velocity. Future systematic reviews will be needed for other emerging radiotracers such as those based on prostate specific membrane antigen and gastrin-releasing peptide receptor.

  14. Multidetector CT enteroclysis: comparison of the reading performance for axial and coronal views

    International Nuclear Information System (INIS)

    Schmidt, Sabine; Chalaron, Marc; Schnyder, Pierre; Denys, Alban; Chevallier, Patrick; Bessoud, Bertrand; Verdun, Francis R.; Frascarolo, Philippe

    2005-01-01

    The purpose of this study was to compare the diagnostic performance of axial and coronal views in multidetector CT enteroclysis (MDCTE). We retrospectively evaluated 48 patients with pathological correlation investigated by MDCTE for small bowel disorders. After nasojejunal administration of 2 l of 5% methylcellulose axial arterial and venous acquisition of MDCTE was followed by coronal reconstructions using equal slice thicknesses of 2.5 mm with 2 mm increments. Spatial resolution of both planes was evaluated by phantom. Three radiologists independently read axial and coronal images concerning 12 pathological features. The interobserver agreement and time of reading was calculated. Sensitivity and specificity resulted from comparison with histopathology (n=39) or follow-up (n=9). Phantom study revealed higher spatial resolution for axial than coronal views, whatever reconstruction interval was used. However, spatial frequency always remained high. Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and intraperitoneal fluid (IPF), showed better interobserver agreement on axial than coronal views (BWT: 0.61 vs. 0.44; BWE: 0.56 vs. 0.5; IPF:0.53 vs. 0.43). The Wilcoxon signed-rank test revealed significantly higher sensitivity for axial than coronal views (P=0.0453); the time of reading was significantly shorter for the latter (P=0.0146). The diagnostic value of axial slices is superior to coronal reconstructions despite the reduced data volume and display of the physiological course of bowel loops on the coronal plane. (orig.)

  15. Imaging results and TOF studies with axial PET detectors

    CERN Document Server

    Joram, Christian

    2013-01-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the held of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The Fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations ( <2 mm FWHM in all three coordinates over the complete held of view) and also demonstrated the ability to include Compton interactions (inter-cr...

  16. Bifurcation and chaos of an axially accelerating viscoelastic beam

    International Nuclear Information System (INIS)

    Yang Xiaodong; Chen Liqun

    2005-01-01

    This paper investigates bifurcation and chaos of an axially accelerating viscoelastic beam. The Kelvin-Voigt model is adopted to constitute the material of the beam. Lagrangian strain is used to account for the beam's geometric nonlinearity. The nonlinear partial-differential equation governing transverse motion of the beam is derived from the Newton second law. The Galerkin method is applied to truncate the governing equation into a set of ordinary differential equations. By use of the Poincare map, the dynamical behavior is identified based on the numerical solutions of the ordinary differential equations. The bifurcation diagrams are presented in the case that the mean axial speed, the amplitude of speed fluctuation and the dynamic viscoelasticity is respectively varied while other parameters are fixed. The Lyapunov exponent is calculated to identify chaos. From numerical simulations, it is indicated that the periodic, quasi-periodic and chaotic motions occur in the transverse vibrations of the axially accelerating viscoelastic beam

  17. Thermocapillary Convection in Floating Zone with Axial Magnetic Fields

    Science.gov (United States)

    Liang, Ruquan; Yang, Shuo; Li, Jizhao

    2014-02-01

    Numerical simulations on the effects of axial magnetic fields on the thermocapillary convection in a liquid bridge of silicone-oil-based ferrofluid under zero gravity have been conducted. The Navier-Stokes equations coupled with the energy conservation equation are solved on a staggered grid, and the mass conserving level set approach is used to capture the free surface deformation of the liquid bridge. The obvious effects of the magnetic fields on the flow pattern as well as the velocity and temperature distributions in the liquid bridge can be detected. The axial magnetic fields suppress the thermocapillary convection and a stagnant flow zone is formed between the circulating flow and the symmetric axis as the magnetic fields increase. The axial magnetic fields affect not only the velocity level inside the liquid bridge but also the velocity level on the free surface. The temperature contours near the free surface illustrates conduction-type temperature profiles at moderate strength fields.

  18. Axial shuffling fuel-management schemes for 1.2% SEU in CANDU

    International Nuclear Information System (INIS)

    Younis, M.H.; Boczar, P.G.

    1989-11-01

    The use of slightly enriched uranium (SEU) in CANDU (CANada Deuterium Uranium) requires a different fuel-management strategy than that usually employed with natural uranium fuel. Axial shuffling is a fuel-management strategy in which some or all of the fuel bundles are removed from the channel, rearranged, and reinserted into the same channel, along with fresh fuel. An axial shuffling scheme has been devised for 1.2% SEU which results in excellent power profiles, from the perspectives of both good axial flattening and power histories. With the CANFLEX (CANdu FLEXible fuelling) advanced fuel bundle, fuel rating can be reduced to below 40kW/m, with consequent safety benefits

  19. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  20. Supercontinuum generation in optimized photonic crystal fiber at 1.3 μm for optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Ferhat M. L.

    2016-01-01

    Full Text Available In this paper, we have designed a high nonlinear photonic crystal fiber (HN-PCF based on square-lattice geometry with the zero dispersion wavelength (ZDW around 1300 nm. The exploitation of different nonlinear mechanisms in the pulse propagation allows supercontinuum generation, which is used to enhance the axial resolution of the optical coherence tomography (OCT systems. First mechanism demonstrated is the soliton self-compression, we came up to realize pulse compression of 28.4 fs around 1300 nm by the generation of solitons of different orders to obtain ultrashort pulses of about 4 fs pulses in a PCF length of 66cm, then, we improved the pulse compression until 1.2 fs in a PCF length of 26 cm.The exploitation of the interplay between many nonlinear effects as self-phase modulation, intrapulse Raman scattering and self-steepening as second mechanism allows a generation of supercontinuum with a spectral bandwith of SBW=260 nm. The obtained spectral bandwidth could contribute to enhance the OCwith OCT imaging axial resolution which can be evaluated to 2.8 μm in air, working at 1.3 μm center wavelength which is widely used in several fields.