WorldWideScience

Sample records for automatic exposure control

  1. Development of Automatic Remote Exposure Controller for Gamma Radiography

    International Nuclear Information System (INIS)

    Joo, Gwang Tae; Shin, Jin Seong; Kim, Dong Eun; Song, Jung Ho; Choo, Seung Hwan; Chang, Hong Keun

    2002-01-01

    Recently, gamma radiographic equipment have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of 0.4∼1.2m/s by BLDC motor of 24V 200W which has output of 54 kgf·, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use

  2. Compatibility of automatic exposure control with new screen phosphors in diagnostic roentgenography

    International Nuclear Information System (INIS)

    Mulvaney, J.A.

    1982-01-01

    Automatic exposure control systems are used in diagnostic roentgenography to obtain proper film density for a variety of patient examinations and roentgenographic techniques. Most automatic exposure control systems have been designed for use with par speed, calcium tungstate intensifying screens. The use of screens with faster speeds and new phosphor materials has put extreme demands on present systems. The performance of a representative automatic exposure control system is investigated to determine its ability to maintain constant film density over a wide range of x-ray tube voltages and acrylic phantom thicknesses with four different intensifying screen phosphors. The effects of x-ray energy dependence, generator switching time and stored change are investigated. The system is able to maintain film density to within plus or minus 0.2 optical density units for techniques representing adult patients. A single nonadjustable tube voltage compensation circuit is adequate for the four different screen phosphors for x-ray tube voltages above sixty peak kilovolts. For techniques representing pediatric patients at high x-ray tube voltages, excess film density occurs due to stored charge in the transformer and high-voltage cables. An anticipation circuit in the automatic exposure control circuit can be modified to correct for stored charge effects. In a seperate experiment the energy dependence of three different ionization chamber detectors used in automatic exposure control systems is compared directly with the energy dependence of three different screen phosphors. The data on detector sensitivity and screen speed are combined to predict the best tube voltage compensation for each combination of screen and detector

  3. A review of automatic exposure control of conventional and digital systems

    International Nuclear Information System (INIS)

    Workman, A.; Cowen, A.R.

    1989-01-01

    The desirable properties and methods of achieving automatic exposure control in film-screen radiography, fluoroscopy, spot-film fluorography and cinefluorography are discussed. Advantages of certain methods in achieving optimum image quality for minimal patient exposure are considered. In digital subtraction fluorography (DSF) where relatively large exposure levels per image are used, proper set-up of exposure conditions is of particular importance. These systems require a high degree of stability in exposure to maintain a high level of image quality. We have developed test methods for monitoring the set-up and reproducibility of exposure levels in DSF. (author)

  4. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion

  5. Results of verifications of the control automatic exposure in equipment of RX with CR systems

    International Nuclear Information System (INIS)

    Ruiz Manzano, P.; Rivas Ballarin, M. A.; Ortega Pardina, P.; Villa Gazulla, D.; Calvo Carrillo, S.; Canellas Anoz, M.; Millan Cebrian, E.

    2013-01-01

    After the entry into force in 2012, the new Spanish Radiology quality control protocol lists and discusses the results obtained after verification of the automatic control of exposure in computed radiography systems. (Author)

  6. Studies on the calibration of mammography automatic exposure mode with computed radiology

    International Nuclear Information System (INIS)

    Zhu Hongzhou; Shao Guoliang; Shi Lei; Liu Qing

    2010-01-01

    Objective: To realize the optimization of image quality and radiation dose by correcting mammography automatic exposure, according to automatic exposure controlled mode of mammography film-screen system. Methods: The film-screen system (28 kV) was applied to perform automatic exposure of plexiglass (40 mm) and get the standard dose of exposure, the exposure mode of CR base on LgM=2.0 was rectified, which was divided into 10 steps. Mammary glands pattern (Fluke NA18-220) were examined with CR (26, 28, and 30 kV) by the automatic exposure mode corrected. The exposure values (mAs) were recorded. CR image was diagnosed and evaluated in double blind way by 4 radiologists according to American Collage of Radiology (ACR) standard. Results: Based on the standard of CR automatic exposure with the dose higher than the traditional exposure of film-screen system, the calibration of mammography automatic exposure was accomplished. The test results of the calibrated mode was better than the scoring system of ACR. Conclusions: Comparative study showed improvement in acquiring high-quality image and reduction of radiation dose. The corrected mammography automatic exposure mode might be a better method for clinical use. (authors)

  7. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N.; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; McKinstry, Robert C. [Barnes Jewish Hospital, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, St. Louis, MO (United States); Vyhmeister, Ross [Washington University School of Medicine, St. Louis, MO (United States); Ramirez-Giraldo, Juan Carlos [Siemens Healthcare, Malvern, PA (United States)

    2015-03-17

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality. (orig.)

  8. Automatization of the radiation control measurements

    International Nuclear Information System (INIS)

    Seki, Akio; Ogata, Harumi; Horikoshi, Yoshinori; Shirai, Kenji

    1988-01-01

    Plutonium Fuel Production Facility (PFPF) was constructed to fabricate the MOX fuels for 'MONJU' and 'JOYO' reactors and to develop the practical fuel fabricating technology. For the fuel fabrication process in this facility, centralized controlling system is being adopted for the mass production of the fuel and reduction of the radiation exposure dose. Also, the radiation control systems are suitable for the large-scale facility and the automatic-remote process of the fuel fabrication. One of the typical radiation control systems is the self moving survey system which has been developed by PNC and adopted for the automatic routine monitoring. (author)

  9. Estimation of effectiveness of automatic exposure control in computed tomograph scanner

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Sharma, S.D.; Datta, D.; Kulkarni, Arti

    2018-01-01

    With the advent of multiple detector array technology, the use of Computed Tomography (CT) scanning has increase tremendously. Computed Tomography examinations deliver relatively high radiation dose to patients in comparison with conventional radiography. It is therefore required to reduce the dose delivered in CT scans without compromising the image quality. Several parameters like applied potential, tube current, scan length, pitch etc. influence the dose delivered in CT scans. For optimization of patient dose and image quality, all modern CT scanners are enabled with Automatic Exposure Control (AEC) systems. The aim of this work is to compare the dose delivered during CT scans performed with and without AEC in order to estimate the effectiveness of AEC techniques used in CT scanners of various manufacturer

  10. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    Science.gov (United States)

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  11. Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography.

    Science.gov (United States)

    Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan

    2015-01-01

    We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.

  12. Positive enteric contrast material for abdominal and pelvic CT with automatic exposure control: What is the effect on patient radiation exposure?

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhen J., E-mail: jane.wang@radiology.ucsf.edu [Department of Radiology, University of California San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143-0628 (United States); Chen, Katherine S.; Gould, Robert; Coakley, Fergus V.; Fu Yanjun; Yeh, Benjamin M. [Department of Radiology, University of California San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143-0628 (United States)

    2011-08-15

    Objective: To assess the effect of positive enteric contrast administration on automatic exposure control (AEC) CT radiation exposure in (1) a CT phantom, and (2) a retrospective review of patients. Materials and methods: We scanned a CT phantom containing simulated bowel that was sequentially filled with water and positive enteric contrast, and recorded the mean volume CT dose index (CTDIvol). We also identified 17 patients who had undergone 2 technically comparable CT scans of the abdomen and pelvis, one with positive enteric contrast and the other with oral water. Paired Student's t-tests were used to compare the mean CTDIvol between scans performed with and without positive enteric contrast. Both the phantom and patient CT scans were performed using AEC with a fixed noise index. Results: The mean CTDIvol for the phantom with simulated bowel containing water and positive enteric contrast were 8.2 {+-} 0.2 mGy, and 8.7 {+-} 0.1 mGy (6.1% higher than water, p = 0.02), respectively. The mean CTDIvol for patients scanned with oral water and with positive enteric contrast were 11.8 mGy and 13.1 mGy, respectively (p = 0.003). This corresponded to a mean CTDIvol which was 11.0% higher (range: 0.0-20.7% higher) in scans with positive enteric contrast than those with oral water in patients. Conclusions: When automatic exposure control is utilized for abdominopelvic CT, the radiation exposure, as measured by CTDIvol, is higher for scans performed with positive enteric contrast than those with oral water.

  13. Automatic Exposure Control Devices for Digital Mammography

    National Research Council Canada - National Science Library

    Fajardo, Laurie

    2000-01-01

    Purpose: The broad, long-term objective of this IDEA proposal is to achieve optimized image quality for DM within acceptable limits of radiation exposure by developing innovative approaches for controlling DM exposures. Scope...

  14. The evaluation of the performance of the automatic exposure control system of some selected mammography facilities in the Greater Accra Region, Ghana

    International Nuclear Information System (INIS)

    Amesimenu, R.

    2013-07-01

    Mammography aids in the early detection of breast cancer. X-rays has an associated risk of inducing cancer though very useful and as such mammography procedures should be optimized through the appropriate processes such as the selection of exposure factors for an optimum image and minimal dose to patients. The automatic exposure control (AEC) aids in the selection of exposure factors thus controlling the amount of radiation to the breast and automatically compensates for differences in the breast thickness and density. The performance of the automatic exposure control system of mammography equipment and the status of quality management systems including quality assurance and quality controls of four (4) mammography facilities within the Greater Accra Region were assessed. In assessing the performance of the automatic exposure control system, the short term reproducibility test, thickness and voltage compensation test were carried out using breast equivalent phantom of various thicknesses. Half value layer test, film reject analysis and patient dose assessment were also performed. Analysis of the responses of the questionnaire administered to radiographers and supervisors of the selected facilities revealed that three (3) of the facilities have some aspect of quality management system programme in place but not effectively implemented. Measured optical densities from the various tests performed to evaluate the performance of the automatic exposure control systems revealed that the AEC compensates for the different phantom thickness and tube voltage (KV) by producing comparable optical densities for the various phantom thickness and tube voltages. Some of the measured optical densities were within the recommended optical density range of 1.5 OD - 1.9 OD. The highest optical density value was 0.13 OD above the highest limit of 1.9 OD. The film reject analysis showed that patient motion accounted for the large part (28%) of film rejects. Other factors such as too light

  15. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  16. CT-automatic exposure control devices: What are their performances?

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Daniel [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland); Schmidt, Sabine; Denys, Alban; Schnyder, Pierre [Radiology Department, University Hospital of Lausanne, CHUV, CH-1011 Lausanne (Switzerland); Bochud, Francois O. [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics (IRA-DUMSC), Grand-Pre 1, CH-1007 Lausanne (Switzerland)], E-mail: francis.verdun@chuv.ch

    2007-10-01

    Purpose: To avoid unnecessary exposure to the patients, constructors have developed tube current modulation algorithms. The purpose of this work is to assess the performance of computed tomography (CT) tube current modulation concerning patient dose and image noise in MSCT scanners. Material and methods: A conical PMMA phantom with elliptical cross-section, to vary the thickness of the irradiated object in a monotonous way, and an anthropomorphic chest phantom were scanned under similar conditions on a general electrics (GE) LightSpeed VCT (64 slices) scanner. Noise measurements were made by calculating the standard deviation of the CT-number on a homogeneous ROI in both phantoms. The dose was estimated with the parameters read in the DICOM header of each studied image. Results: The study has shown that most of the time, constant noise levels (noise index) can be obtained by a variation of the mA. Nevertheless, this adaptation can be not fast enough when the variation of the attenuation changes is rapid. Thus, an adaptation length up to 5 cm was obtained. A 18% dose reduction can be achieved (mean of 9.9%) by switching from z-axis modulation algorithm to xyz-axis modulation option. However, exposure in the chest area can be higher with current modulation than without, when trying to keep an image noise level constant in thoraco-abdominal investigations. Conclusion: Current modulation algorithms can produce inadequate quality images due to problems with tube current stabilization when a sudden attenuation variation takes place as at the start of a scanning sequence. As expected, rotational (xyz-axis) modulation performs better than only z-axis modulation algorithm. The use of automatic exposure control (AEC) can lead to an increase of the dose if the maximum allowed current is not properly set in thoraco-abdominal acquisitions.

  17. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  18. Assessment of automatic exposure control performance in digital mammography using a no-reference anisotropic quality index

    Science.gov (United States)

    Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.

  19. Exposure to violent video games increases automatic aggressiveness.

    Science.gov (United States)

    Uhlmann, Eric; Swanson, Jane

    2004-02-01

    The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games predicted automatic aggressive self-concept, above and beyond self-reported aggression. Results suggest that playing violent video games can lead to the automatic learning of aggressive self-views.

  20. Comparison of entry kerma in the skin with the variation of automatic exposure control in mammography;Comparacao do kerma de entrada na pele com a variacao do controle automatico de exposicao em exames mamograficos

    Energy Technology Data Exchange (ETDEWEB)

    Macao Junior, J.L. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Mecca, F.A. [Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Gomes, B.C. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The purpose of this work was to analyze the entry kerma values in the skin in comparison with the automatic exposure control tests. To achieve that, 44 mammographies were evaluatecl in the city of Rio de Janeiro. The reference values adopted were taken from the current Brazilian legislation, 'Portaria no. 453/98 do Ministerio da Saude', where the reference entry kerma value in the skin corresponds to 10 mGy and the maximum variation accepted to the automatic exposure control test corresponds to 30 optic unities. It was observed that 46.7% of the analyzecl mammographies presented entry kerma values in the skin above the reference level established, whereas the automatic exposition control for these same mammographies was within the acceptability parameters. (author)

  1. X-ray conditions and response characteristics of automatic dose control in cinematography

    International Nuclear Information System (INIS)

    Arai, Hiroaki

    1997-01-01

    X-ray characteristics including subject thickness (copper plate), tube voltage, tube current and irradiation time were measured at stability, with an automatic dose control x-ray generator for cineangiography. Regardless of subject thickness, it is possible that the energy input to the x-ray tube in one frame may be decreased. The automatic control response was measured after rapid fluctuation in subject thickness. Two inverter-type x-ray generators with different automatic control units were studied. The older control unit changes exposure dose by tube voltage and tube current, while the newer one changes exposure dose by tube voltage, tube current and irradiation time. The maximum rate of change in tube voltage is greater with the newer control unit. In addition, the actual tube current response of the newer control unit in increasing nominal value is faster than the older one. In the new control unit, for each pulse, irradiation is cut off by means of a signal that the exposure has reached the proper value. Thus given the same differential in subject thickness, the newer control unit resumed stability faster than the older one. (author)

  2. X-ray conditions and response characteristics of automatic dose control in cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Hiroaki [Cardiovascular Institute Hospital, Tokyo (Japan)

    1997-11-01

    X-ray characteristics including subject thickness (copper plate), tube voltage, tube current and irradiation time were measured at stability, with an automatic dose control x-ray generator for cineangiography. Regardless of subject thickness, it is possible that the energy input to the x-ray tube in one frame may be decreased. The automatic control response was measured after rapid fluctuation in subject thickness. Two inverter-type x-ray generators with different automatic control units were studied. The older control unit changes exposure dose by tube voltage and tube current, while the newer one changes exposure dose by tube voltage, tube current and irradiation time. The maximum rate of change in tube voltage is greater with the newer control unit. In addition, the actual tube current response of the newer control unit in increasing nominal value is faster than the older one. In the new control unit, for each pulse, irradiation is cut off by means of a signal that the exposure has reached the proper value. Thus given the same differential in subject thickness, the newer control unit resumed stability faster than the older one. (author)

  3. Results of verifications of the control automatic exposure in equipment of RX with CR systems; Resultados de las verificaciones del control automatico de exposicion en equipos de RX con sistemas CR

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Manzano, P.; Rivas Ballarin, M. A.; Ortega Pardina, P.; Villa Gazulla, D.; Calvo Carrillo, S.; Canellas Anoz, M.; Millan Cebrian, E.

    2013-07-01

    After the entry into force in 2012, the new Spanish Radiology quality control protocol lists and discusses the results obtained after verification of the automatic control of exposure in computed radiography systems. (Author)

  4. Microprocessor-controlled inhalation system for repeated exposure of animals to aerosols

    International Nuclear Information System (INIS)

    Carpenter, R.L.; Barr, F.P.; Leydig, R.L.; Rajala, R.E.

    1979-01-01

    A microprocessor-controlled inhalation exposure system (MCIES) has been built to automate aerosol generation and sampling while controlling exposure time for animal toxicity studies. The system has a time resolution of 0.1 s and automatically sequences the exposure events from initiation to temination of the exposure. The operator is required to preset all airflows, read in a paper tape containing the time sequence of events, and initiate the automatic sequence by closing a switch

  5. Variation in the quality of CT images of the upper abdomen when CT automatic exposure control is employed

    International Nuclear Information System (INIS)

    Aizawa, Isao; Muramatsu, Yoshihisa; Nomura, Keiichi; Shimizu, Fuminori

    2010-01-01

    The aim of this study was to analyze the reason for variation of image quality in the upper abdomen CT with the use of CT-automatic exposure control (AEC). The CT investigated was 3D modulation in the 16 multi detector row CT (MDCT) and lung cancer screening CT (LSCT) phantom was used to simulate the patient. When there was a phase difference, an image noise increase of around 15% at the maximum was accepted. It is concluded that the major reason for variation in image quality is respiratory motion and the importance of respiration control must be recognized. (author)

  6. Reasonable selection of automatic exposure density compensation of ionization chamber

    International Nuclear Information System (INIS)

    Tian Fuqiang; Nie Shikun; Wang Zhihong; Zeng Jianhua; Cheng Guanxun; Xiang Qian

    2000-01-01

    Objective: To introduce and discuss the methods of reasonable selection of the automatic exposure density compensation of ionization chamber to provide important references for clinic radiograph and improve the quality of images. Methods: X-ray machines with ionization chamber automatic exposure control system were used in this study. Compared with the standard baseline of the normal density of the object radio-graphed, the reasonable ionization chamber density compensation (IDC) was chosen and compared with the radiograph without IDC through a water model test and density measurement. Results: There was no significant difference between two groups (100 films each) which were randomly divided to the group with or without IDC, but there was statistically significant difference in the special groups. Conclusion: To select suitable IDC is very important for guaranteeing radiographic quality, moreover, to establish a suitable kV is also necessary, usually it is 10 to 20 kV higher than the optioned kV. The relative factors must be fixed relatively and be matched correctly

  7. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  8. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  9. Exposure to Violent Video Games Increases Automatic Aggressiveness

    Science.gov (United States)

    Uhlmann, Eric; Swanson, Jane

    2004-01-01

    The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games…

  10. Automatic exposure control in computed tomography - an evaluation of systems from different manufacturers

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, Marcus; Gunnarsson, Mikael (Dept. of Medical Radiation Physics, Skaane Univ. Hospital, Malmoe (Sweden)), e-mail: marcus.soderberg@med.lu.se

    2010-07-15

    Background: Today, practically all computed tomography (CT) systems are delivered with automatic exposure control (AEC) systems operating with tube current modulation in three dimensions. Each of these systems has different specifications and operates somewhat differently. Purpose: To evaluate AEC systems from four different CT scanner manufacturers: General Electric (GE), Philips, Siemens, and Toshiba, considering their potential for reducing radiation exposure to the patient while maintaining adequate image quality. Material and Methods: The dynamics (adaptation along the longitudinal axis) of tube current modulation of each AEC system were investigated by scanning an anthropomorphic chest phantom using both 16- and 64-slice CT scanners from each manufacturer with the AEC systems activated and inactivated. The radiation dose was estimated using the parameters in the DICOM image information and image quality was evaluated based on image noise (standard deviation of CT numbers) calculated in 0.5 cm2 circular regions of interest situated throughout the spine region of the chest phantom. Results: We found that tube current modulation dynamics were similar among the different AEC systems, especially between GE and Toshiba systems and between Philips and Siemens systems. Furthermore, the magnitude of the reduction in the exposure dose was considerable, in the range of 35-60%. However, in general the image noise increased when the AEC systems were used, especially in regions where the tube current was greatly decreased, such as the lung region. However, the variation in image noise among images obtained along the scanning direction was lower when using the AEC systems compared with fixed mAs. Conclusion: The AEC systems available in modern CT scanners can contribute to a significant reduction in radiation exposure to the patient and the image noise becomes more uniform within any given scan.

  11. Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results

    International Nuclear Information System (INIS)

    Greess, H.; Bautz, W.; Baum, U.; Wolf, H.; Suess, C.; Kalender, W.A.

    2004-01-01

    Purpose: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. Materials and Methods: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n=26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. Results: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31% to 66% in children (mean 44%) and between 35% and 64% in adults (mean 53%), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. Conclusion: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality. (orig.) [de

  12. Female gonadal shielding with automatic exposure control increases radiation risks

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, Summer L.; Zhu, Xiaowei [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA (United States); Magill, Dennise; Felice, Marc A. [University of Pennsylvania, Environmental Health and Radiation Safety, Philadelphia, PA (United States); Xiao, Rui [University of Pennsylvania, Department of Biostatistics and Epidemiology, Philadelphia, PA (United States); Ali, Sayed [Temple University Hospital, Department of Radiology, Philadelphia, PA (United States)

    2018-02-15

    Gonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose to colon and stomach as well as to ovaries outside the shielded area. We assess changes in dose-area product (DAP) and absorbed organ dose when female gonadal shielding is used with AEC for pelvis radiography. We imaged adult and 5-year-old equivalent dosimetry phantoms using pelvis radiograph technique with AEC in the presence and absence of a female gonadal shield. We recorded DAP and mAs and measured organ absorbed dose at six internal sites using film dosimetry. Female gonadal shielding with AEC increased DAP 63% for the 5-year-old phantom and 147% for the adult phantom. Absorbed organ dose at unshielded locations of colon, stomach and ovaries increased 21-51% in the 5-year-old phantom and 17-100% in the adult phantom. Absorbed organ dose sampled under the shield decreased 67% in the 5-year-old phantom and 16% in the adult phantom. Female gonadal shielding combined with AEC during pelvic radiography increases absorbed dose to organs with greater radiation sensitivity and to unshielded ovaries. Difficulty in proper use of gonadal shields has been well described, and use of female gonadal shielding may be inadvisable given the risks of increasing radiation. (orig.)

  13. Female gonadal shielding with automatic exposure control increases radiation risks

    International Nuclear Information System (INIS)

    Kaplan, Summer L.; Zhu, Xiaowei; Magill, Dennise; Felice, Marc A.; Xiao, Rui; Ali, Sayed

    2018-01-01

    Gonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose to colon and stomach as well as to ovaries outside the shielded area. We assess changes in dose-area product (DAP) and absorbed organ dose when female gonadal shielding is used with AEC for pelvis radiography. We imaged adult and 5-year-old equivalent dosimetry phantoms using pelvis radiograph technique with AEC in the presence and absence of a female gonadal shield. We recorded DAP and mAs and measured organ absorbed dose at six internal sites using film dosimetry. Female gonadal shielding with AEC increased DAP 63% for the 5-year-old phantom and 147% for the adult phantom. Absorbed organ dose at unshielded locations of colon, stomach and ovaries increased 21-51% in the 5-year-old phantom and 17-100% in the adult phantom. Absorbed organ dose sampled under the shield decreased 67% in the 5-year-old phantom and 16% in the adult phantom. Female gonadal shielding combined with AEC during pelvic radiography increases absorbed dose to organs with greater radiation sensitivity and to unshielded ovaries. Difficulty in proper use of gonadal shields has been well described, and use of female gonadal shielding may be inadvisable given the risks of increasing radiation. (orig.)

  14. Female gonadal shielding with automatic exposure control increases radiation risks.

    Science.gov (United States)

    Kaplan, Summer L; Magill, Dennise; Felice, Marc A; Xiao, Rui; Ali, Sayed; Zhu, Xiaowei

    2018-02-01

    Gonadal shielding remains common, but current estimates of gonadal radiation risk are lower than estimated risks to colon and stomach. A female gonadal shield may attenuate active automatic exposure control (AEC) sensors, resulting in increased dose to colon and stomach as well as to ovaries outside the shielded area. We assess changes in dose-area product (DAP) and absorbed organ dose when female gonadal shielding is used with AEC for pelvis radiography. We imaged adult and 5-year-old equivalent dosimetry phantoms using pelvis radiograph technique with AEC in the presence and absence of a female gonadal shield. We recorded DAP and mAs and measured organ absorbed dose at six internal sites using film dosimetry. Female gonadal shielding with AEC increased DAP 63% for the 5-year-old phantom and 147% for the adult phantom. Absorbed organ dose at unshielded locations of colon, stomach and ovaries increased 21-51% in the 5-year-old phantom and 17-100% in the adult phantom. Absorbed organ dose sampled under the shield decreased 67% in the 5-year-old phantom and 16% in the adult phantom. Female gonadal shielding combined with AEC during pelvic radiography increases absorbed dose to organs with greater radiation sensitivity and to unshielded ovaries. Difficulty in proper use of gonadal shields has been well described, and use of female gonadal shielding may be inadvisable given the risks of increasing radiation.

  15. Overview, practical tips and potential pitfalls of using automatic exposure control in CT: Siemens care dose 4D

    International Nuclear Information System (INIS)

    Soederberg, Marcus

    2016-01-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. (authors)

  16. Automatic control systems engineering

    International Nuclear Information System (INIS)

    Shin, Yun Gi

    2004-01-01

    This book gives descriptions of automatic control for electrical electronics, which indicates history of automatic control, Laplace transform, block diagram and signal flow diagram, electrometer, linearization of system, space of situation, state space analysis of electric system, sensor, hydro controlling system, stability, time response of linear dynamic system, conception of root locus, procedure to draw root locus, frequency response, and design of control system.

  17. Automatic Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Preuss, Mike

    2014-01-01

    Automatically generating computer animations is a challenging and complex problem with applications in games and film production. In this paper, we investigate howto translate a shot list for a virtual scene into a series of virtual camera configurations — i.e automatically controlling the virtual...

  18. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    Reina, Thamiris Rosado

    2014-01-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  19. Evaluation of automatic exposure control systems in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Reina, Thamiris Rosado

    2014-07-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  20. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  1. Electronic device for automatic control of exposure in radiography

    International Nuclear Information System (INIS)

    Pendharkar, A.S.; Jayakumar, T.K.

    1977-01-01

    An electronic instrument for calculating and controlling exposure in radiography practice using radioisotopes is described. When using this equipment, only factor to be known is the dose required by the film for a given density and the thickness of material inspected. It eliminates all the problems arising out of various parameters such as source decay etc in the conventional procedure for calculating exposure time. Principle of operation, the electronic circuitry adopted and the functional aspects of the system are described in detail. Exposure doses for different industrial films have been related to the instrumental readouts. The system reproducibility and reliability have been evaluated. The advantages and limitations of the present system and the future development to overcome the problems are indicated. (author)

  2. 46 CFR 52.01-10 - Automatic controls.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic controls. 52.01-10 Section 52.01-10 Shipping... Requirements § 52.01-10 Automatic controls. (a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this chapter. (b) Each automatically controlled auxiliary...

  3. In-Plane Shielding for CT: Effect of Off-Centering, Automatic Exposure Control and Shield-to-Surface Distance

    Energy Technology Data Exchange (ETDEWEB)

    Kalra, Mannudeep K.; Dang, Pragya; Singh, Sarabjeet; Saini, Sanjay; Shepard, Jo Anne O. [Massachusetts General Hospital, Boston (United States)

    2009-04-15

    To assess effects of off-centering, automatic exposure control, and padding on attenuation values, noise, and radiation dose when using in-plane bismuth-based shields for CT scanning. A 30 cm anthropomorphic chest phantom was scanned on a 64-multidetector CT, with the center of the phantom aligned to the gantry isocenter. Scanning was repeated after placing a bismuth breast shield on the anterior surface with no gap and with 1, 2, and 6 cm of padding between the shield and the phantom surface. The 'shielded' phantom was also scanned with combined modulation and off-centering of the phantom at 2 cm, 4 cm and 6 cm below the gantry isocenter. CT numbers, noise, and surface radiation dose were measured. The data were analyzed using an analysis of variance. The in-plane shield was not associated with any significant increment for the surface dose or CT dose index volume, which was achieved by comparing the radiation dose measured by combined modulation technique to the fixed mAs (p > 0.05). Irrespective of the gap or the surface CT numbers, surface noise increased to a larger extent compared to Hounsfield unit (HU) (0-6 cm, 26-55%) and noise (0-6 cm, 30-40%) in the center. With off-centering, in-plane shielding devices are associated with less dose savings, although dose reduction was still higher than in the absence of shielding (0 cm off-center, 90% dose reduction; 2 cm, 61%) (p < 0.0001). Streak artifacts were noted at 0 cm and 1 cm gaps but not at 2 cm and 6 cm gaps of shielding to the surface distances. In-plane shields are associated with greater image noise, artificially increased attenuation values, and streak artifacts. However, shields reduce radiation dose regardless of the extent of off-centering. Automatic exposure control did not increase radiation dose when using a shield.

  4. A practical method to standardise and optimise the Philips DoseRight 2.0 CT automatic exposure control system.

    Science.gov (United States)

    Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W

    2015-09-01

    Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.

  5. Study of the effect of the variation of automatic exposure control in computed tomography; Estudio del efecto de la variacion del control automatico de exposicion en tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Nersissian, D. Y.; Capeleti, F. F.; Furquin, T. A. C.; Melo, C. S.

    2011-07-01

    Teams computed tomography (CT) contain the current automatic control of exposure (CAE) which vary from the current X-ray tube in clinical protocols and deliver lower doses than those with fixed current. Alone is not enough control of dose, you need an acceptable image quality ensuring an accurate diagnosis. The TC regulate the flow of two ways: by considering the thickness of the patient and the attenuation by different tissues that intercept the x-ray Besides the advantage, there is the responsibility of proper use of different CAE systems, which require particular knowledge of each manufacturer of the CT.

  6. SU-E-I-24: Method for CT Automatic Exposure Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Gracia, M; Olasolo, J; Martin, M; Bragado, L; Gallardo, N; Miquelez, S; Maneru, F; Lozares, S; Pellejero, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain)

    2015-06-15

    Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomex electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.

  7. Automatic and deliberate affective associations with sexual stimuli in women with lifelong vaginismus before and after therapist-aided exposure treatment.

    Science.gov (United States)

    Melles, Reinhilde J; ter Kuile, Moniek M; Dewitte, Marieke; van Lankveld, Jacques J D M; Brauer, Marieke; de Jong, Peter J

    2014-03-01

    The intense fear response to vaginal penetration in women with lifelong vaginismus, who have never been able to experience coitus, may reflect negative automatic and deliberate appraisals of vaginal penetration stimuli which might be modified by exposure treatment. The aim of this study is to examine whether (i) sexual stimuli elicit relatively strong automatic and deliberate threat associations in women with vaginismus, as well as relatively negative automatic and deliberate global affective associations, compared with symptom-free women; and (ii) these automatic and more deliberate attitudes can be modified by therapist-aided exposure treatment. A single target Implicit Association Test (st-IAT) was used to index automatic threat associations, and an Affective Simon Task (AST) to index global automatic affective associations. Participants were women with lifelong vaginismus (N = 68) and women without sexual problems (N = 70). The vaginismus group was randomly allocated to treatment (n = 34) and a waiting list control condition (n = 34). Indices of automatic threat were obtained by the st-IAT and automatic global affective associations by the AST, visual analogue scales (VAS) were used to assess deliberate appraisals of the sexual pictures (fear and global positive affect). More deliberate fear and less global positive affective associations with sexual stimuli were found in women with vaginismus. Following therapist-aided exposure treatment, the strength of fear was strongly reduced, whereas global positive affective associations were strengthened. Automatic associations did not differ between women with and without vaginismus and did not change following treatment. Relatively stronger negative (threat or global affect) associations with sexual stimuli in vaginismus appeared restricted to the deliberate level. Therapist-aided exposure treatment was effective in reducing subjective fear of sexual penetration stimuli and led to more global positive affective

  8. Automatic positioning control device for automatic control rod exchanger

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To attain accurate positioning for a control rod exchanger. Constitution: The present position for an automatic control rod exchanger is detected by a synchro generator. An aimed stopping position for the exchanger, a stop instruction range depending on the distantial operation delay in the control system and the inertia-running distance of the mechanical system, and a coincidence confirmation range depending on the required positioning accuracy are previously set. If there is a difference between the present position and the aimed stopping position, the automatic exchanger is caused to run toward the aimed stopping position. A stop instruction is generated upon arrival at the position within said stop instruction range, and a coincidence confirmation signal is generated upon arrival at the position within the coincidence confirmation range. Since uncertain factors such as operation delay in the control system and the inertia-running distance of the mechanical system that influence the positioning accuracy are made definite by the method of actual measurement or the like and the stop instruction range and the coincidence confirmation range are set based on the measured data, the accuracy for the positioning can be improved. (Ikeda, J.)

  9. Automatic plasma control in magnetic traps

    International Nuclear Information System (INIS)

    Samojlenko, Y.; Chuyanov, V.

    1984-01-01

    Hot plasma is essentially in thermodynamic non-steady state. Automatic plasma control basically means monitoring deviations from steady state and producing a suitable magnetic or electric field which brings the plasma back to its original state. Briefly described are two systems of automatic plasma control: control with a magnetic field using a negative impedance circuit, and control using an electric field. It appears that systems of automatic plasma stabilization will be an indispensable component of the fusion reactor and its possibilities will in many ways determine the reactor economy. (Ha)

  10. Development of the automatic control rod operation system for JOYO. Verification of automatic control rod operation guide system

    International Nuclear Information System (INIS)

    Terakado, Tsuguo; Suzuki, Shinya; Kawai, Masashi; Aoki, Hiroshi; Ohkubo, Toshiyuki

    1999-10-01

    The automatic control rod operation system was developed to control the JOYO reactor power automatically in all operation modes(critical approach, cooling system heat up, power ascent, power descent), development began in 1989. Prior to applying the system, verification tests of the automatic control rod operation guide system was conducted during 32nd duty cycles of JOYO' from Dec. 1997 to Feb. 1998. The automatic control rod operation guide system consists of the control rod operation guide function and the plant operation guide function. The control rod operation guide function provides information on control rod movement and position, while the plant operation guide function provide guidance for plant operations corresponding to reactor power changes(power ascent or power descent). Control rod insertion or withdrawing are predicted by fuzzy algorithms. (J.P.N.)

  11. 30 CFR 77.314 - Automatic temperature control instruments.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic temperature control instruments. 77... UNDERGROUND COAL MINES Thermal Dryers § 77.314 Automatic temperature control instruments. (a) Automatic temperature control instruments for thermal dryer system shall be of the recording type. (b) Automatic...

  12. Automatic intelligent cruise control

    OpenAIRE

    Stanton, NA; Young, MS

    2006-01-01

    This paper reports a study on the evaluation of automatic intelligent cruise control (AICC) from a psychological perspective. It was anticipated that AICC would have an effect upon the psychology of driving—namely, make the driver feel like they have less control, reduce the level of trust in the vehicle, make drivers less situationally aware, but might reduce the workload and make driving might less stressful. Drivers were asked to drive in a driving simulator under manual and automatic inte...

  13. Automatic control system at the ''Loviisa'' NPP

    International Nuclear Information System (INIS)

    Kukhtevich, I.V.; Mal'tsev, B.K.; Sergievskaya, E.N.

    1980-01-01

    Automatic control system of the Loviisa-1 NPP (Finland) is described. According to operation conditions of Finland power system the Loviisa-1 NPP must operate in the mode of week and day control of loading schedule and participate in current control of power system frequency and capacity. With provision for these requirements NPP is equipped with the all-regime system for automatic control functioning during reactor start-up, shut-down, in normal and transient regimes and in emergency situations. The automatic control system includes: a data subsystem, an automatic control subsystem, a discrete control subsystem including remote, a subsystem for reactor control and protection and overall station system of protections: control and dosimetry inside the reactor. Structures of a data-computer complex, discrete control subsystems, reactor control and protection systems, neutron flux control system, inside-reactor control system, station protection system and system for control of fuel element tightness are presented in short. Two-year experience of the NPP operation confirmed advisability of the chosen volume of automatization. The Loviisa-1 NPP operates successfully in the mode of the week and day control of supervisor schedule and current control of frequency (short-term control)

  14. Automatic control of nuclear power plants

    International Nuclear Information System (INIS)

    Jover, P.

    1976-01-01

    The fundamental concepts in automatic control are surveyed, and the purpose of the automatic control of pressurized water reactors is given. The response characteristics for the main components are then studied and block diagrams are given for the main control loops (turbine, steam generator, and nuclear reactors) [fr

  15. PET radiation exposure control for nurses

    International Nuclear Information System (INIS)

    Kawabata, Yumiko; Kikuta, Daisuke; Anzai, Taku

    2005-01-01

    Recently, the number of clinical PET centers is increasing all over Japan. For this reason, the monitoring and control of radiation exposure of employees, especially nurses, in PET-dedicated clinics and institutions are becoming very important issues for their health. We measured the radiation exposure doses of the nurses working at Nishidai Diagnostic Imaging Center, and analyzed the exposure data obtained from them. The exposure doses of the nurses were found to be 4.8 to 7.1 mSv between April 2003 and March 2004. We found that the nurses were mostly exposed to radiation when they had to have contact with patients received an FDG injection or they had trouble with the FDG automatic injection system. To keep radiation exposure of nurses to a minimum we reconfirmed that a proper application of the three principles of protection against radiation exposure was vital. (author)

  16. Tuning of automatic exposure control strength in lumbar spine CT.

    Science.gov (United States)

    D'Hondt, A; Cornil, A; Bohy, P; De Maertelaer, V; Gevenois, P A; Tack, D

    2014-05-01

    To investigate the impact of tuning the automatic exposure control (AEC) strength curve (specific to Care Dose 4D®; Siemens Healthcare, Forchheim, Germany) from "average" to "strong" on image quality, radiation dose and operator dependency during lumbar spine CT examinations. Two hospitals (H1, H2), both using the same scanners, were considered for two time periods (P1 and P2). During P1, the AEC curve was "average" and radiographers had to select one of two protocols according to the body mass index (BMI): "standard" if BMI 30.0 kg m(-2) (140 kV-280 mAs). During P2, the AEC curve was changed to "strong", and all acquisitions were obtained with one protocol (120 kV and 270 mAs). Image quality was scored and patients' diameters calculated for both periods. 497 examinations were analysed. There was no significant difference in mean diameters according to hospitals and periods (p > 0.801) and in quality scores between periods (p > 0.172). There was a significant difference between hospitals regarding how often the "large" protocol was assigned [13 (10%)/132 patients in H1 vs 37 (28%)/133 in H2] (p < 0.001). During P1, volume CT dose index (CTDIvol) was higher in H2 (+13%; p = 0.050). In both hospitals, CTDIvol was reduced between periods (-19.2% in H1 and -29.4% in H2; p < 0.001). An operator dependency in protocol selection, unexplained by patient diameters or highlighted by image quality scores, has been observed. Tuning the AEC curve from average to strong enables suppression of the operator dependency in protocol selection and related dose increase, while preserving image quality. CT acquisition protocols based on weight are responsible for biases in protocol selection. Using an appropriate AEC strength curve reduces the number of protocols to one. Operator dependency of protocol selection is thereby eliminated.

  17. 12th Portuguese Conference on Automatic Control

    CERN Document Server

    Soares, Filomena; Moreira, António

    2017-01-01

    The biennial CONTROLO conferences are the main events promoted by The CONTROLO 2016 – 12th Portuguese Conference on Automatic Control, Guimarães, Portugal, September 14th to 16th, was organized by Algoritmi, School of Engineering, University of Minho, in partnership with INESC TEC, and promoted by the Portuguese Association for Automatic Control – APCA, national member organization of the International Federation of Automatic Control – IFAC. The seventy-five papers published in this volume cover a wide range of topics. Thirty-one of them, of a more theoretical nature, are distributed among the first five parts: Control Theory; Optimal and Predictive Control; Fuzzy, Neural and Genetic Control; Modeling and Identification; Sensing and Estimation. The papers go from cutting-edge theoretical research to innovative control applications and show expressively how Automatic Control can be used to increase the well being of people. .

  18. 49 CFR 236.825 - System, automatic train control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false System, automatic train control. 236.825 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.825 System, automatic train control. A system so arranged that its operation will automatically...

  19. 30 CFR 77.1401 - Automatic controls and brakes.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic controls and brakes. 77.1401 Section... MINES Personnel Hoisting § 77.1401 Automatic controls and brakes. Hoists and elevators shall be equipped with overspeed, overwind, and automatic stop controls and with brakes capable of stopping the elevator...

  20. Automatic exchange unit for control rod drive device

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To enable automatic reoperation and continuation without external power interruption remedy device at the time of recovering the interrupted power soruce during automatic positioning operation. Constitution: In case of an automatic exchange unit for a control rod drive device of the control type for setting the deviation between the positioning target position and the present position of the device to zero, the position data of the drive device of the positioning target value of the device is automatically read, and an interlock of operation inhibit is applied to a control system until the data reading is completed and automatic operation start or restart conditions are sequentially confirmed. After the confirmation, the interlock is released to start the automatic operation or reoperation. Accordingly, the automatic operation can be safely restarted and continued. (Yoshihara, H.)

  1. Interactivity in automatic control: foundations and experiences

    OpenAIRE

    Dormido Bencomo, Sebastián; Guzmán Sánchez, José Luis; Costa Castelló, Ramon; Berenguel, M

    2012-01-01

    The first part of this paper presents the concepts of interactivity and visualization and its essential role in learning the fundamentals and techniques of automatic control. More than 10 years experience of the authors in the development and design of interactive tools dedicated to the study of automatic control concepts are also exposed. The second part of the paper summarizes the main features of the “Automatic Control with Interactive Tools” text that has been recently published by Pea...

  2. [Advances in research on automatic exposure control of mammography system].

    Science.gov (United States)

    Wang, Guoyi; Ye, Chengfu; Wu, Haiming; Wang, Tainfu; Zhang, Hong

    2014-12-01

    Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.

  3. Effect of automatic exposure control marker with chest radiography in radiation reduction

    International Nuclear Information System (INIS)

    Jung, Ji Sang; Choi, Byoung Wook; Shim, Ji Na; Ahn, Ho Sik; Jin, Duk Eun; Liml, Jae Sik; Kang, Sung Ho; Kim, Sung Ho; Kim, Young Mo

    2014-01-01

    This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size 17 x 17 inch, 120 kVp, FFD 180 cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56 mGycm2, Mean effective dose is 0.045 mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36 mGycm2, Mean effective dose is 0.041 mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056 mSv (limit point to know efficiency of AEC marker) is 65 in control group(14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose

  4. Effect of automatic exposure control marker with chest radiography in radiation reduction

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ji Sang; Choi, Byoung Wook; Shim, Ji Na; Ahn, Ho Sik; Jin, Duk Eun; Liml, Jae Sik; Kang, Sung Ho [Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Sung Ho [LISTEM, Woonju (Korea, Republic of); Kim, Young Mo [Dept. of Biomedical Engineering, Konyang University, Nonsan (Korea, Republic of)

    2014-09-15

    This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size 17 x 17 inch, 120 kVp, FFD 180 cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56 mGycm2, Mean effective dose is 0.045 mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36 mGycm2, Mean effective dose is 0.041 mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056 mSv (limit point to know efficiency of AEC marker) is 65 in control group(14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

  5. Phototimer for automatic control of x-ray exposure, PT-20A

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, H; Itoh, K; Ogura, I; Yasuhara, H; Sugimoto, H [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-02-01

    The phototimer as an exposure control device is now required to have higher accuracy and wider range of control to comply with the recent trends of x-ray diagnosis, such as toward short-time exposure due to increased output power of x-ray apparatus and toward one-man operation. In order to meet the requirement, the x-ray characteristics of the components of the phototimer have been examined, and computer simulation of x-ray spectra and dynamic characteristics of every component have been investigated, in pursuit of the essential characters of phototimers. On the basis of these analytical investigations, the phototimer PT-20A is so designed as to compensate for density deviation under various kVp and object thickness: uniform density has been obtained under practical radiographic conditions.

  6. Microprocessor controlled system for automatic and semi-automatic syntheses of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Ruth, T.J.; Adam, M.J.; Morris, D.; Jivan, S.

    1986-01-01

    A computer based system has been constructed to control the automatic synthesis of 2-deoxy-2-( 18 F)fluoro-D-glucose and is also being used in the development of an automatic synthesis of L-6-( 18 F)fluorodopa. (author)

  7. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  8. Automatic Control of Silicon Melt Level

    Science.gov (United States)

    Duncan, C. S.; Stickel, W. B.

    1982-01-01

    A new circuit, when combined with melt-replenishment system and melt level sensor, offers continuous closed-loop automatic control of melt-level during web growth. Installed on silicon-web furnace, circuit controls melt-level to within 0.1 mm for as long as 8 hours. Circuit affords greater area growth rate and higher web quality, automatic melt-level control also allows semiautomatic growth of web over long periods which can greatly reduce costs.

  9. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    Science.gov (United States)

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  10. The Use of Automatic Indexing for Authority Control.

    Science.gov (United States)

    Dillon, Martin; And Others

    1981-01-01

    Uses an experimental system for authority control on a collection of bibliographic records to demonstrate the resemblance between thesaurus-based automatic indexing and automatic authority control. Details of the automatic indexing system are given, results discussed, and the benefits of the resemblance examined. Included are a rules appendix and…

  11. Method for automatic control rod operation using rule-based control

    International Nuclear Information System (INIS)

    Kinoshita, Mitsuo; Yamada, Naoyuki; Kiguchi, Takashi

    1988-01-01

    An automatic control rod operation method using rule-based control is proposed. Its features are as follows: (1) a production system to recognize plant events, determine control actions and realize fast inference (fast selection of a suitable production rule), (2) use of the fuzzy control technique to determine quantitative control variables. The method's performance was evaluated by simulation tests on automatic control rod operation at a BWR plant start-up. The results were as follows; (1) The performance which is related to stabilization of controlled variables and time required for reactor start-up, was superior to that of other methods such as PID control and program control methods, (2) the process time to select and interpret the suitable production rule, which was the same as required for event recognition or determination of control action, was short (below 1 s) enough for real time control. The results showed that the method is effective for automatic control rod operation. (author)

  12. Automatic control of commercial computer programs

    International Nuclear Information System (INIS)

    Rezvov, B.A.; Artem'ev, A.N.; Maevskij, A.G.; Demkiv, A.A.; Kirillov, B.F.; Belyaev, A.D.; Artem'ev, N.A.

    2010-01-01

    The way of automatic control of commercial computer programs is presented. The developed connection of the EXAFS spectrometer automatic system (which is managed by PC for DOS) is taken with the commercial program for the CCD detector control (which is managed by PC for Windows). The described complex system is used for the automation of intermediate amplitude spectra processing in EXAFS spectrum measurements at Kurchatov SR source

  13. Performance of automatic exposure control of digital imaging systems in three big hospitals

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Dyakov, I.

    2012-01-01

    The digital imaging systems are quite new in Bulgaria and there is still no clear evidence between all the servicing companies how to set the automatic exposure control (AEC) of the systems. The aim of this work is to study the AEC settings of the digital imaging systems in three big hospitals, serviced by different engineering companies. This study included seven systems, one with digital radiography (DR) and the others with computed radiography (CR) detectors. The AEC settings were tested in terms of mean pixel value (MPV), air kerma at phantom exit and detector dose indicator (DDI) dependence from AEC chamber selection, tube voltage and phantom thickness. Relatively small variations in MPV up to 8 % were observed for 4 of the CR systems, usually with small variations in DDI as well (except for one system, for which up to 40 % difference in DDI consistency between chambers was found). Air kerma at phantom exit for these systems had bigger variations up to 29 %. The other CR systems had big variations in MPV up to 57 % with DDI variations up to 30 % while air kerma changes were not small - from 8 to 38 %. The DR system showed smaller variation in air kerma at phantom exit up to 8 % and bigger variations in MPV and DDI up to 20 % and 15 % respectively. There is no systematic approach in the AEC settings used in the 3 hospitals. Further investigation and collaboration with the servicing companies is needed aiming to establish the optimized selection of AEC calibration parameters in each case. (authors)

  14. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  15. Towards Automatic Decentralized Control Structure Selection

    DEFF Research Database (Denmark)

    Jørgensen, John Bagterp; Jørgensen, Sten Bay

    2000-01-01

    for decentralized control is determined automatically, and the resulting decentralized control structure is automatically tuned using standard techniques. Dynamic simulation of the resulting process system gives immediate feedback to the process design engineer regarding practical operability of the process......A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and control design. As soon as the process is specified or computed, a structure....... The control structure selection problem is formulated as a special MILP employing cost coefficients which are computed using Parseval's theorem combined with RGA and IMC concepts. This approach enables selection and tuning of large-scale plant-wide decentralized controllers through efficient combination...

  16. Towards Automatic Decentralized Control Structure Selection

    DEFF Research Database (Denmark)

    for decentralized control is determined automatically, and the resulting decentralized control structure is automatically tuned using standard techniques. Dynamic simulation of the resulting process system gives immediate feedback to the process design engineer regarding practical operability of the process......A subtask in integration of design and control of chemical processes is the selection of a control structure. Automating the selection of the control structure enables sequential integration of process and controld esign. As soon as the process is specified or computed, a structure....... The control structure selection problem is formulated as a special MILP employing cost coefficients which are computed using Parseval's theorem combined with RGA and IMC concepts. This approach enables selection and tuning of large-scale plant-wide decentralized controllers through efficient combination...

  17. Automatic brightness control algorithms and their effect on fluoroscopic imaging

    International Nuclear Information System (INIS)

    Quinn, P.W.; Gagne, R.M.

    1989-01-01

    This paper reports a computer model used to investigate the effect on dose and image quality of three automatic brightness control (ABC) algorithms used in the imaging of barium during general-purpose fluoroscopy. A model incorporating all aspects of image formation - i.e., x- ray production, phantom attenuation, and energy absorption in the CSI phosphor - was driven according to each ABC algorithm as a function of patient thickness. The energy absorbed in the phosphor was kept constant, while the changes in exposure, integral dose, organ dose, and contrast were monitored

  18. Implementation Of Automatic Wiper Speed Control And Headlight Modes Control Systems Using Fuzzy Logic

    OpenAIRE

    ThetKoKo; ZawMyoTun; Hla Myo Tun

    2015-01-01

    Abstract This research paper describes the design and simulation of the automatic wiper speed and headlight modes controllers using fuzzy logic. This proposed system consists of a fuzzy logic controller to control a cars wiper speed and headlight modes. The automatic wiper system detects the rain and its intensity. And according to the rain intensity the wiper speed is automatically controlled. Headlight modes automatically changes either from low beam mode to high beam mode or form high beam...

  19. 2nd International Conference on Mechatronics and Automatic Control

    CERN Document Server

    2015-01-01

    This book examines mechatronics and automatic control systems. The book covers important emerging topics in signal processing, control theory, sensors, mechanic manufacturing systems and automation. The book presents papers from the second International Conference on Mechatronics and Automatic Control Systems held in Beijing, China on September 20-21, 2014. Examines how to improve productivity through the latest advanced technologies Covering new systems and techniques in the broad field of mechatronics and automatic control systems.

  20. Automatic operation device for control rods

    International Nuclear Information System (INIS)

    Sekimizu, Koichi

    1984-01-01

    Purpose: To enable automatic operation of control rods based on the reactor operation planning, and particularly, to decrease the operator's load upon start up and shutdown of the reactor. Constitution: Operation plannings, demand for the automatic operation, break point setting value, power and reactor core flow rate change, demand for operation interrupt, demand for restart, demand for forecasting and the like are inputted to an input device, and an overall judging device performs a long-term forecast as far as the break point by a long-term forecasting device based on the operation plannings. The automatic reactor operation or the like is carried out based on the long-term forecasting and the short time forecasting is performed by the change in the reactor core status due to the control rod operation sequence based on the control rod pattern and the operation planning. Then, it is judged if the operation for the intended control rod is possible or not based on the result of the short time forecasting. (Aizawa, K.)

  1. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    Science.gov (United States)

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  2. Automatic weld torch guidance control system

    Science.gov (United States)

    Smaith, H. E.; Wall, W. A.; Burns, M. R., Jr.

    1982-01-01

    A highly reliable, fully digital, closed circuit television optical, type automatic weld seam tracking control system was developed. This automatic tracking equipment is used to reduce weld tooling costs and increase overall automatic welding reliability. The system utilizes a charge injection device digital camera which as 60,512 inidividual pixels as the light sensing elements. Through conventional scanning means, each pixel in the focal plane is sequentially scanned, the light level signal digitized, and an 8-bit word transmitted to scratch pad memory. From memory, the microprocessor performs an analysis of the digital signal and computes the tracking error. Lastly, the corrective signal is transmitted to a cross seam actuator digital drive motor controller to complete the closed loop, feedback, tracking system. This weld seam tracking control system is capable of a tracking accuracy of + or - 0.2 mm, or better. As configured, the system is applicable to square butt, V-groove, and lap joint weldments.

  3. Adaptive pseudolinear compensators of dynamic characteristics of automatic control systems

    Science.gov (United States)

    Skorospeshkin, M. V.; Sukhodoev, M. S.; Timoshenko, E. A.; Lenskiy, F. V.

    2016-04-01

    Adaptive pseudolinear gain and phase compensators of dynamic characteristics of automatic control systems are suggested. The automatic control system performance with adaptive compensators has been explored. The efficiency of pseudolinear adaptive compensators in the automatic control systems with time-varying parameters has been demonstrated.

  4. Automatic Strain-Rate Controller,

    Science.gov (United States)

    1976-12-01

    D—AO37 9~e2 ROME AIR DEVELOPMENT CENTER GRIFFISS AFB N 1’ FIG 13/ 6AUTOMATIC STRAIN—RATE CONTROLLER, (U) DEC 76 R L HUNTSINGER. J A ADAMSK I...goes to zero. CONTROLLER, Leeds and Northrup Series 80 CAT with proportional band , rate , reset, and approach controls . Input from deviation output...8) through ( 16) . (8) Move the set-point slowl y up to 3 or 4. (9) If the recorder po inter hunts , adjust the func t ion controls on tine Ser

  5. Automatic control variac system for electronic accelerator

    International Nuclear Information System (INIS)

    Zhang Shuocheng; Wang Dan; Jing Lan; Qiao Weimin; Ma Yunhai

    2006-01-01

    An automatic control variac system is designed in order to satisfy the controlling requirement of the electronic accelerator developed by the Institute. Both design and operational principles, structure of the system as well as the software of industrial PC and micro controller unit are described. The interfaces of the control module are RS232 and RS485. A fiber optical interface (FOC) could be set up if an industrial FOC network is necessary, which will extend the filed of its application and make the communication of the system better. It is shown in practice that the system can adjust the variac output voltage automatically and assure the accurate and automatic control of the electronic accelerator. The system is designed in accordance with the general design principles and possesses the merits such as easy operation and maintenance, good expansibility, and low cost, thus it could also be used in other industrial branches. (authors)

  6. 14 CFR 25.904 - Automatic takeoff thrust control system (ATTCS).

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Automatic takeoff thrust control system... Automatic takeoff thrust control system (ATTCS). Each applicant seeking approval for installation of an engine power control system that automatically resets the power or thrust on the operating engine(s) when...

  7. [Automatic adjustment control system for DC glow discharge plasma source].

    Science.gov (United States)

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  8. Automatic-Control System for Safer Brazing

    Science.gov (United States)

    Stein, J. A.; Vanasse, M. A.

    1986-01-01

    Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.

  9. Methods for CT automatic exposure control protocol translation between scanner platforms.

    Science.gov (United States)

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  10. Automatic Control of Freeboard and Turbine Operation

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter Bak; Friis-Madsen, Erik

    The report deals with the modules for automatic control of freeboard and turbine operation on board the Wave dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003.......The report deals with the modules for automatic control of freeboard and turbine operation on board the Wave dragon, Nissum Bredning (WD-NB) prototype, and covers what has been going on up to ultimo 2003....

  11. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    Science.gov (United States)

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  12. Automatic control design procedures for restructurable aircraft control

    Science.gov (United States)

    Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.

    1985-01-01

    A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.

  13. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data

    International Nuclear Information System (INIS)

    Charnock, P.; Jones, R.; Fazakerley, J.; Wilde, R.; Dunn, A. F.

    2011-01-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Inst. of Physics and Engineering in Medicine (IPEM) report 91 recommends that milli amperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilo voltage used with these records then used to plot average monthly milli amperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated. (authors)

  14. Automatic Control Of Length Of Welding Arc

    Science.gov (United States)

    Iceland, William F.

    1991-01-01

    Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

  15. Automatic power control for a pressurized water reactor

    International Nuclear Information System (INIS)

    Hah, Yung Joon

    1994-02-01

    During a normal operation of a pressurized water reactor (PWR), the reactivity is controlled by control rods, boron, and the average temperature of the primary coolant. Especially in load follow operation, the reactivity change is induced by changes in power level and effects of xenon concentration. The control of the core power distribution is concerned, mainly, with the axial power distribution which depends on insertion and withdrawal of the control rods resulting in additional reactivity compensation. The utilization of part strength control element assemblies (PSCEAs) is quite appropriate for a control of the power distribution in the case of Yonggwang Nuclear Unit 3 (YGN Unit 3). However, control of the PSCEAs is not automatic, and changes in the boron concentration by dilution/boration are done manually. Thus, manual control of the PSCEAs and the boron concentration require the operator's experience and knowledge for a successful load follow operation. In this thesis, the new concepts have been proposed to adapt for an automatic power control in a PWR. One of the new concepts is the mode K control, another is a fuzzy power control. The system in mode K control implements a heavy-worth bank dedicated to axial shape control, independent of the existing regulating banks. The heavy bank provides a monotonic relationship between its motion and the axial power shape change, which allows automatic control of the axial power distribution. And the mode K enables precise regulation, by using double closed-loop control of the reactor coolant temperature and the axial power difference. Automatic reactor power control permits the nuclear power plant to accommodate the load follow operations, including frequency control, to respond to the grid requirements. The mode K reactor control concepts were tested using simulation responses of a Korean standardized 1000-MWe PWR which is a reference plant for the YGN Unit 3. The simulation results illustrate that the mode K would be

  16. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  17. Evolutionary game dynamics of controlled and automatic decision-making.

    Science.gov (United States)

    Toupo, Danielle F P; Strogatz, Steven H; Cohen, Jonathan D; Rand, David G

    2015-07-01

    We integrate dual-process theories of human cognition with evolutionary game theory to study the evolution of automatic and controlled decision-making processes. We introduce a model in which agents who make decisions using either automatic or controlled processing compete with each other for survival. Agents using automatic processing act quickly and so are more likely to acquire resources, but agents using controlled processing are better planners and so make more effective use of the resources they have. Using the replicator equation, we characterize the conditions under which automatic or controlled agents dominate, when coexistence is possible and when bistability occurs. We then extend the replicator equation to consider feedback between the state of the population and the environment. Under conditions in which having a greater proportion of controlled agents either enriches the environment or enhances the competitive advantage of automatic agents, we find that limit cycles can occur, leading to persistent oscillations in the population dynamics. Critically, however, these limit cycles only emerge when feedback occurs on a sufficiently long time scale. Our results shed light on the connection between evolution and human cognition and suggest necessary conditions for the rise and fall of rationality.

  18. Evolutionary game dynamics of controlled and automatic decision-making

    Science.gov (United States)

    Toupo, Danielle F. P.; Strogatz, Steven H.; Cohen, Jonathan D.; Rand, David G.

    2015-07-01

    We integrate dual-process theories of human cognition with evolutionary game theory to study the evolution of automatic and controlled decision-making processes. We introduce a model in which agents who make decisions using either automatic or controlled processing compete with each other for survival. Agents using automatic processing act quickly and so are more likely to acquire resources, but agents using controlled processing are better planners and so make more effective use of the resources they have. Using the replicator equation, we characterize the conditions under which automatic or controlled agents dominate, when coexistence is possible and when bistability occurs. We then extend the replicator equation to consider feedback between the state of the population and the environment. Under conditions in which having a greater proportion of controlled agents either enriches the environment or enhances the competitive advantage of automatic agents, we find that limit cycles can occur, leading to persistent oscillations in the population dynamics. Critically, however, these limit cycles only emerge when feedback occurs on a sufficiently long time scale. Our results shed light on the connection between evolution and human cognition and suggest necessary conditions for the rise and fall of rationality.

  19. Automatic Control of the Concrete Mixture Homogeneity in Cycling Mixers

    Science.gov (United States)

    Anatoly Fedorovich, Tikhonov; Drozdov, Anatoly

    2018-03-01

    The article describes the factors affecting the concrete mixture quality related to the moisture content of aggregates, since the effectiveness of the concrete mixture production is largely determined by the availability of quality management tools at all stages of the technological process. It is established that the unaccounted moisture of aggregates adversely affects the concrete mixture homogeneity and, accordingly, the strength of building structures. A new control method and the automatic control system of the concrete mixture homogeneity in the technological process of mixing components have been proposed, since the tasks of providing a concrete mixture are performed by the automatic control system of processing kneading-and-mixing machinery with operational automatic control of homogeneity. Theoretical underpinnings of the control of the mixture homogeneity are presented, which are related to a change in the frequency of vibrodynamic vibrations of the mixer body. The structure of the technical means of the automatic control system for regulating the supply of water is determined depending on the change in the concrete mixture homogeneity during the continuous mixing of components. The following technical means for establishing automatic control have been chosen: vibro-acoustic sensors, remote terminal units, electropneumatic control actuators, etc. To identify the quality indicator of automatic control, the system offers a structure flowchart with transfer functions that determine the ACS operation in transient dynamic mode.

  20. 2013 International Conference on Mechatronics and Automatic Control Systems

    CERN Document Server

    2014-01-01

    This book examines mechatronics and automatic control systems. The book covers important emerging topics in signal processing, control theory, sensors, mechanic manufacturing systems and automation. The book presents papers from the 2013 International Conference on Mechatronics and Automatic Control Systems held in Hangzhou, China on August 10-11, 2013. .

  1. Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    Science.gov (United States)

    Kopp, Ruedger; Bensberg, Ralf; Stollenwerk, Andre; Arens, Jutta; Grottke, Oliver; Walter, Marian; Rossaint, Rolf

    2016-10-01

    Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requirements. Therefore, we developed a demonstrator with an integrated control algorithm to keep continuously measured peripheral oxygen saturation and partial pressure of carbon dioxide constant by automatically adjusting extracorporeal blood and gas flow. The "SmartECLA" system was tested in six animal experiments with increasing pulmonary hypoventilation and hypoxic inspiratory gas mixture to simulate progressive acute respiratory failure. During a cumulative evaluation time of 32 h for all experiments, automatic ECLA control resulted in a peripheral oxygen saturation ≥90% for 98% of the time with the lowest value of 82% for 15 s. Partial pressure of venous carbon dioxide was between 40 and 49 mm Hg for 97% of the time with no value 49 mm Hg. With decreasing inspiratory oxygen concentration, extracorporeal oxygen uptake increased from 68 ± 25 to 154 ± 34 mL/min (P < 0.05), and reducing respiratory rate resulted in increasing extracorporeal carbon dioxide elimination from 71 ± 37 to 92 ± 37 mL/min (P < 0.05). The "SmartECLA" demonstrator allowed reliable automatic control of the extracorporeal circuit. Proof of concept could be demonstrated for this novel automatically controlled veno-venous ECLA circuit. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Automatic exposure system for radioactive source at teaching laboratory

    International Nuclear Information System (INIS)

    Seren, Maria Emilia G.; Gaal, Vladmir; Morais, Sergio Luiz de; Rodrigues, Varlei

    2013-01-01

    The development of Compton Scattering experiment, studied by undergraduate students of the Medical Physics course at the Universidade Estadual de Campinas (UNICAMP), takes place in the Medical Physics Teaching Laboratory, belonging to the Gleb Wataghin Physics Institute (IFGW/UNICAMP). The experiment consists of a fixed 137 Cs radioactive source, with current activity of 610.5 MBq and a scintillation detector that turns around the center of the system whose function is to detect the scattered photons spectrum by a scatter object (target). The 137 Cs source is stored in a lead shield with a collimating window for the gamma radiation emitted with energy of 0.662 MeV. This source is exposed only when an attenuation barrier protecting the collimating window is opened. The process of opening and closing the attenuation barrier may deliver a radiation dose to users when done manually. Considering the stochastic harmful effects of ionizing radiation, the goal of this project was to develop an automatic exposure system of the radioactive source, in order to reduce the radiation dose received during the Compton Scattering experiment. The developed system is micro controlled and performs standard operating routines, responding to emergencies. Furthermore, an electromagnetic lock enables quick closing of the barrier by gravity, in case of interruption of the electrical current circuit. Besides reducing the total dose to lab users, the system adds more security to the routine, since it limits the access to the radioactive source and prevents accidental exposure. (author)

  3. Controlled versus automatic processes: which is dominant to safety? The moderating effect of inhibitory control.

    Directory of Open Access Journals (Sweden)

    Yaoshan Xu

    Full Text Available This study explores the precursors of employees' safety behaviors based on a dual-process model, which suggests that human behaviors are determined by both controlled and automatic cognitive processes. Employees' responses to a self-reported survey on safety attitudes capture their controlled cognitive process, while the automatic association concerning safety measured by an Implicit Association Test (IAT reflects employees' automatic cognitive processes about safety. In addition, this study investigates the moderating effects of inhibition on the relationship between self-reported safety attitude and safety behavior, and that between automatic associations towards safety and safety behavior. The results suggest significant main effects of self-reported safety attitude and automatic association on safety behaviors. Further, the interaction between self-reported safety attitude and inhibition and that between automatic association and inhibition each predict unique variances in safety behavior. Specifically, the safety behaviors of employees with lower level of inhibitory control are influenced more by automatic association, whereas those of employees with higher level of inhibitory control are guided more by self-reported safety attitudes. These results suggest that safety behavior is the joint outcome of both controlled and automatic cognitive processes, and the relative importance of these cognitive processes depends on employees' individual differences in inhibitory control. The implications of these findings for theoretical and practical issues are discussed at the end.

  4. FRICTION - WELDING MACHINE AUTOMATIC CONTROL CIRCUIT DESIGN AND APPLICATION

    OpenAIRE

    Hakan ATEŞ; Ramazan BAYINDIR

    2003-01-01

    In this work, automatic controllability of a laboratory-sized friction-welding machine has been investigated. The laboratory-sized friction-welding machine was composed of motor, brake, rotary and constant samples late pliers, and hydraulic unit. In automatic method, welding parameters such as friction time, friction pressure, forge time and forge pressure can be applied sensitively using time relays and contactors. At the end of the experimental study it's observed that automatic control sys...

  5. Discrete Model Reference Adaptive Control System for Automatic Profiling Machine

    Directory of Open Access Journals (Sweden)

    Peng Song

    2012-01-01

    Full Text Available Automatic profiling machine is a movement system that has a high degree of parameter variation and high frequency of transient process, and it requires an accurate control in time. In this paper, the discrete model reference adaptive control system of automatic profiling machine is discussed. Firstly, the model of automatic profiling machine is presented according to the parameters of DC motor. Then the design of the discrete model reference adaptive control is proposed, and the control rules are proven. The results of simulation show that adaptive control system has favorable dynamic performances.

  6. An evaluation of three simple phantoms used in quality assurance of automatic exposure control

    International Nuclear Information System (INIS)

    Reynolds, S.E.; Rofe, S.

    2000-01-01

    Full text: Different attenuators are used to assess the performance of x-ray systems with automatic exposure control (AEC). Three attenuators, copper, water and hardboard, were compared in this assessment. The Health Physics Service (HPS), which is part of the Department of Medical Physics and Bioengineering at Christchurch Hospital, New Zealand, has chosen to use hardboard as its patient equivalent phantom when testing x-ray equipment simply because it is generally easier to handle compared to water phantoms. Tests were conducted on the hardboard phantom in order to evaluate its effect on radiation in terms of attenuation equivalence, production of scatter and sensitivity to different kilovoltages compared to water or copper. Entrance and exit dose comparison tests were conducted using the AEC on a Philips Optimus 50 x-ray machine. A Keithley Triad Field Service Kit Model 10100A was used to record doses. The first set of tests were designed to ascertain the thickness of water and copper required to produce a similar mAs to the particular thickness of hardboard being examined. The tests were repeated with a film in a cassette which was placed in the bucky tray. Film optical densities were then measured. The hardboard phantom shows a very similar response to radiation as water and hence the human body and is therefore a suitable material for use in the construction of phantoms. Copper produces a very different radiation spectrum and its scattering effects are quite different to water or hardboard. For these reasons we consider copper to be unsuitable for use as a phantom when programming AECs. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  7. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    Science.gov (United States)

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  8. 46 CFR 161.002-10 - Automatic fire detecting system control unit.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Automatic fire detecting system control unit. 161.002-10...-10 Automatic fire detecting system control unit. (a) General. The fire detecting system control unit... and the battery to be charged. (h) Automatic fire detecting system, battery charging and control—(1...

  9. 3D automatic exposure control for 64-detector row CT: Radiation dose reduction in chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Atsushi [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Inokawa, Hiroyasu [Toshiba Medical Systems, Ohtawara, Tochigi (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, Kobe, Hyogo (Japan); Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Araki, Tsutomu [Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2011-03-15

    Purpose: The purpose of this study was to determine the utility of three-dimensional (3D) automatic exposure control (AEC) for low-dose CT examination in a chest phantom study. Materials and methods: A chest CT phantom including simulated focal ground-glass opacities (GGOs) and nodules was scanned with a 64-detector row CT with and without AEC. Performance of 3D AEC included changing targeted standard deviations (SDs) of image noise from scout view. To determine the appropriate targeted SD number for identification, the capability of overall identification with the CT protocol adapted to each of the targeted SDs was compared with that obtained with CT without AEC by means of receiver operating characteristic analysis. Results: When targeted SD values equal to or higher than 250 were used, areas under the curve (Azs) of nodule identification with CT protocol using AEC were significantly smaller than that for CT protocol without AEC (p < 0.05). When targeted SD numbers at equal to or more than 180 were adapted, Azs of CT protocol with AEC had significantly smaller than that without AEC (p < 0.05). Conclusion: This phantom study shows 3D AEC is useful for low-dose lung CT examination, and can reduce the radiation dose while maintaining good identification capability and good image quality.

  10. FRICTION - WELDING MACHINE AUTOMATIC CONTROL CIRCUIT DESIGN AND APPLICATION

    Directory of Open Access Journals (Sweden)

    Hakan ATEŞ

    2003-02-01

    Full Text Available In this work, automatic controllability of a laboratory-sized friction-welding machine has been investigated. The laboratory-sized friction-welding machine was composed of motor, brake, rotary and constant samples late pliers, and hydraulic unit. In automatic method, welding parameters such as friction time, friction pressure, forge time and forge pressure can be applied sensitively using time relays and contactors. At the end of the experimental study it's observed that automatic control system has been worked successfully.

  11. Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle

    Science.gov (United States)

    Chen, Hongbin

    2018-03-01

    Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.

  12. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R; Avery, G; Balcam, S; Needler, L

    2014-01-01

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQ m ), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQ m  and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma. (paper)

  13. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R

    2014-05-07

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  14. Different involvement of medial prefrontal cortex and dorso-lateral striatum in automatic and controlled processing of a future conditioned stimulus.

    Science.gov (United States)

    Pérez-Díaz, Francisco; Díaz, Estrella; Sánchez, Natividad; Vargas, Juan Pedro; Pearce, John M; López, Juan Carlos

    2017-01-01

    Recent studies support the idea that stimulus processing in latent inhibition can vary during the course of preexposure. Controlled attentional mechanisms are said to be important in the early stages of preexposure, while in later stages animals adopt automatic processing of the stimulus to be used for conditioning. Given this distinction, it is possible that both types of processing are governed by different neural systems, affecting differentially the retrieval of information about the stimulus. In the present study we tested if a lesion to the dorso-lateral striatum or to the medial prefrontal cortex has a selective effect on exposure to the future conditioned stimulus (CS). With this aim, animals received different amounts of exposure to the future CS. The results showed that a lesion to the medial prefrontal cortex enhanced latent inhibition in animals receiving limited preexposure to the CS, but had no effect in animals receiving extended preexposure to the CS. The lesion of the dorso-lateral striatum produced a decrease in latent inhibition, but only in animals with an extended exposure to the future conditioned stimulus. These results suggest that the dorsal striatum and medial prefrontal cortex play essential roles in controlled and automatic processes. Automatic attentional processes appear to be impaired by a lesion to the dorso-lateral striatum and facilitated by a lesion to the prefrontal cortex.

  15. 46 CFR 61.30-20 - Automatic control and safety tests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic control and safety tests. 61.30-20 Section 61... TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...

  16. Automatic Flight Controller With Model Inversion

    Science.gov (United States)

    Meyer, George; Smith, G. Allan

    1992-01-01

    Automatic digital electronic control system based on inverse-model-follower concept being developed for proposed vertical-attitude-takeoff-and-landing airplane. Inverse-model-follower control places inverse mathematical model of dynamics of controlled plant in series with control actuators of controlled plant so response of combination of model and plant to command is unity. System includes feedback to compensate for uncertainties in mathematical model and disturbances imposed from without.

  17. Structure of the automatic system for plasma equilibrium position control

    International Nuclear Information System (INIS)

    Gubarev, V.F.; Krivonos, Yu.G.; Samojlenko, Yu.I.; Snegur, A.A.

    1978-01-01

    Considered are the principles of construction of the automatic system for plasma filament equilibrium position control inside the discharge chamber for the installation of a tokamak type. The combined current control system in control winding is suggested. The most powerful subsystem creates current in the control winding according to the program calculated beforehand. This system provides plasma rough equilibrium along the ''big radius''. The subsystem performing the current change in small limits according to the principle of feed-back coupling is provided simultaneously. The stabilization of plasma position is achieved in the discharge chamber. The advantage of construction of such system is in decreasing of the automatic requlator power without lowering the requirements to the accuracy of equilibrium preservation. The subsystem of automatic control of plasma position over the vertical is put into the system. Such an approach to the construction of the automatic control system proves to be correct; it is based on the experience of application of similar devices for some existing thermonuclear plants

  18. Freezing of gait in Parkinson’s disease: disturbances in automaticity and control

    Directory of Open Access Journals (Sweden)

    Jochen eVandenbossche

    2013-01-01

    Full Text Available Recent studies emphasize a key role of controlled operations, such as set-shifting and inhibition, in the occurrence of freezing of gait (FOG in Parkinson’s disease (PD. However, FOG can also be characterized as a de-automatization disorder, showing impairments in both the execution and acquisition of automaticity. The observed deficits in automaticity and executive functioning indicate that both processes are malfunctioning in freezers. Therefore, to explain FOG from a cognitive-based perspective, we present a model describing the pathways involved in automatic and controlled processes prior to a FOG episode. Crucially, we focus on disturbances in automaticity and control, regulated by the frontostriatal circuitry. In complex situations, non-freezing PD patients may compensate for deficits in automaticity by switching to increased cognitive control. However, as both automatic and controlled processes are more severely impaired in freezers, this hampers cognitive compensation in FOG, resulting in a potential breakdown. Future directions for cognitive rehabilitation are proposed, based on the cognitive model we put forward.

  19. 11th Portuguese Conference on Automatic Control

    CERN Document Server

    Matos, Aníbal; Veiga, Germano

    2015-01-01

    During the last 20 years the Portuguese association of automatic control, Associação Portuguesa de Controlo Automático, with the sponsorship of IFAC have established the CONTROLO conference as a reference international forum where an effective exchange of knowledge and experience amongst researchers active in various theoretical and applied areas of systems and control can take place, always including considerable space for promoting new technical applications and developments, real-world challenges and success stories. In this 11th edition the CONTROLO conference evolved by introducing two strategic partnerships with Spanish and Brazilian associations in automatic control, Comité Español de Automática and Sociedade Brasileira de Automatica, respectively.

  20. Application of nonlinear transformations to automatic flight control

    Science.gov (United States)

    Meyer, G.; Su, R.; Hunt, L. R.

    1984-01-01

    The theory of transformations of nonlinear systems to linear ones is applied to the design of an automatic flight controller for the UH-1H helicopter. The helicopter mathematical model is described and it is shown to satisfy the necessary and sufficient conditions for transformability. The mapping is constructed, taking the nonlinear model to canonical form. The performance of the automatic control system in a detailed simulation on the flight computer is summarized.

  1. Fuzzy-Neural Automatic Daylight Control System

    Directory of Open Access Journals (Sweden)

    Grif H. Şt.

    2011-12-01

    Full Text Available The paper presents the design and the tuning of a CMAC controller (Cerebellar Model Articulation Controller implemented in an automatic daylight control application. After the tuning process of the controller, the authors studied the behavior of the automatic lighting control system (ALCS in the presence of luminance disturbances. The luminance disturbances were produced by the authors in night conditions and day conditions as well. During the night conditions, the luminance disturbances were produced by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances were produced in two ways: by daylight contributions changes achieved by covering and uncovering a part of the office window and by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances, produced by turning on and off the halogen lamp, have a smaller amplitude than those produced during the night conditions. The luminance disturbance during the night conditions was a helpful tool to select the proper values of the learning rate for CMAC controller. The luminance disturbances during the day conditions were a helpful tool to demonstrate the right setting of the CMAC controller.

  2. Automatic Tuning of Control Parameters for Single Speed Engines

    OpenAIRE

    Olsson, Johan

    2004-01-01

    In Scania’s single speed engines for industrial and marine use, the engine speed is controlled by a PI-controller. This controller is tuned independent of engine type and application. This brings certain disadvantages since the engines are used in a wide range of applications where the dynamics may differ. In this thesis, the possibility to tune the controller automatically for a specific engine installation has been investigated. The work shows that automatic tuning is possible. By performin...

  3. Fuzzy algorithm for an automatic reactor power control in a PWR

    International Nuclear Information System (INIS)

    Hah, Yung Joon; Song, In Ho; Yu, Sung Sik; Choi, Jung In; Lee, Byong Whi

    1994-01-01

    A fuzzy algorithm is presented for automatic reactor power control in a pressurized water reactor. Automatic power shape control is complicated by the use of control rods because it is highly coupled with reactivity compensation. Thus, manual shape controls are usually employed even for the limited capability for the load - follow operation including frequency control. In an attempt to achieve automatic power shape control without any design modification of the core, a fuzzy power control algorithm is proposed. For the fuzzy control, the rule base is formulated based on a multi - input multi - output system. The minimum operation rule and the center of area method are implemented for the development of the fuzzy algorithm. The fuzzy power control algorithm has been applied to the Yonggwang Nuclear Unit 3. The simulation results show that the fuzzy control can be adapted as a practical control strategy for automatic reactor power control of the pressurized water reactor during the load - follow operation

  4. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    Science.gov (United States)

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Implementation Of Automatic Wiper Speed Control And Headlight Modes Control Systems Using Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    ThetKoKo

    2015-07-01

    Full Text Available Abstract This research paper describes the design and simulation of the automatic wiper speed and headlight modes controllers using fuzzy logic. This proposed system consists of a fuzzy logic controller to control a cars wiper speed and headlight modes. The automatic wiper system detects the rain and its intensity. And according to the rain intensity the wiper speed is automatically controlled. Headlight modes automatically changes either from low beam mode to high beam mode or form high beam mode to low beam mode depending on the light intensity from the other vehicle coming from the opposite direction. The system comprises of PIC impedance sensor piezoelectric vibration sensor LDR headlamps and a DC motor to accurate the windshield wiper. Piezoelectric sensor is used to detect the rain intensity which is based on the piezoelectric effect. MATLAB software is used to achieve the designed goal.

  6. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    International Nuclear Information System (INIS)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship 'Mutsu'. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  7. Development of advanced automatic control system for nuclear ship. 2. Perfect automatic operation after reactor scram events

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Noriaki; Nakazawa, Toshio; Takahashi, Hiroki; Shimazaki, Junya; Hoshi, Tsutao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    An automatic operation system has been developed for the purpose of realizing a perfect automatic plant operation after reactor scram events. The goal of the automatic operation after a reactor scram event is to bring the reactor hot stand-by condition automatically. The basic functions of this system are as follows; to monitor actions of the equipments of safety actions after a reactor scram, to control necessary control equipments to bring a reactor to a hot stand-by condition automatically, and to energize a decay heat removal system. The performance evaluation on this system was carried out by comparing the results using to Nuclear Ship Engineering Simulation System (NESSY) and the those measured in the scram test of the nuclear ship `Mutsu`. As the result, it was showed that this system had the sufficient performance to bring a reactor to a hot syand-by condition quickly and safety. (author)

  8. Analysis of automobile’s automatic control systems for the hill climbing start

    Directory of Open Access Journals (Sweden)

    Valeriy I. Klimenko

    2014-12-01

    Full Text Available To improve road safety while driving on the rise, facilitating the driver’s activity the automobile industry leaders are introducing automatic hill-hold control systems into the car design. This study purpose relates to the existing automatic start control systems’ design analysis. Analyzed are the existing design developments of automatic hill start assist control systems applied for driving at the start of the climbing. The effected research allows to select the scheme for further development of start driving automatic control systems. Further improvement of driving control systems and primarily the driver assistance hill-hold control systems is necessary to increase both the driving comfort and the traffic safety.

  9. On a program manifold's stability of one contour automatic control systems

    Science.gov (United States)

    Zumatov, S. S.

    2017-12-01

    Methodology of analysis of stability is expounded to the one contour systems automatic control feedback in the presence of non-linearities. The methodology is based on the use of the simplest mathematical models of the nonlinear controllable systems. Stability of program manifolds of one contour automatic control systems is investigated. The sufficient conditions of program manifold's absolute stability of one contour automatic control systems are obtained. The Hurwitz's angle of absolute stability was determined. The sufficient conditions of program manifold's absolute stability of control systems by the course of plane in the mode of autopilot are obtained by means Lyapunov's second method.

  10. Experience in designing the automatic nuclear power plant control system

    International Nuclear Information System (INIS)

    Sedov, V.K.; Busygin, B.F.; Eliseeva, O.V.; Mikhajlov, V.A.

    1981-01-01

    The integrated automatic control system (ACS) is designed at the Novovoronezh NPP (NVNPP). It comprises automatic technological control of all the five power un+ts and the plant in the whole (ACST) and automatic organizational-economic production control system (ACSP). The NVNPP ACS is designed as a two-level system. The two M-4030 and M-4030-1 computers are the technical base of the upper layer while a set of block NPP (computer-M-60 and M-700 for unit 5; M-60 and SM-2 for units 1-4) of the lower level. Block diagram of the NVNPP ACS, flowsheet of NVNPP ACS technical means and external communications of the control centre are described. The NVNPP ACS is supposed to be put into operation by stages. It is noted that design and introduction of the typical NPP ACS at the NVNPP permits to maximally reduce in the future the period of developing automatic control systems at nly introduced units and NPPs with the WWER reactors [ru

  11. AUTOMATIC FREQUENCY CONTROL SYSTEM

    Science.gov (United States)

    Hansen, C.F.; Salisbury, J.D.

    1961-01-10

    A control is described for automatically matching the frequency of a resonant cavity to that of a driving oscillator. The driving oscillator is disconnected from the cavity and a secondary oscillator is actuated in which the cavity is the frequency determining element. A low frequency is mixed with the output of the driving oscillator and the resultant lower and upper sidebands are separately derived. The frequencies of the sidebands are compared with the secondary oscillator frequency. deriving a servo control signal to adjust a tuning element in the cavity and matching the cavity frequency to that of the driving oscillator. The driving oscillator may then be connected to the cavity.

  12. [An automatic system controlled by microcontroller for carotid sinus perfusion].

    Science.gov (United States)

    Yi, X L; Wang, M Y; Fan, Z Z; He, R R

    2001-08-01

    To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.

  13. Automatic wipers with mist control

    OpenAIRE

    Ashik K.P; A.N.Basavaraju

    2016-01-01

    - This paper illustrates Automatic wipers with mist control. In modern days, the accidents are most common in commercial vehicles. One of the reasons for these accidents is formation of the mist inside the vehicle due to heavy rain. In rainy seasons for commercial vehicles, the wiper on the windshield has to be controlled by the driver himself, which distracts his concentration on driving. Also when the rain lasts for more time (say for about 15 minutes) the formation of mist on t...

  14. Commutated automatic gain control system

    Science.gov (United States)

    Yost, S. R.

    1982-01-01

    A commutated automatic gain control (AGC) system was designed and built for a prototype Loran C receiver. The receiver uses a microcomputer to control a memory aided phase-locked loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The circuit designed for the AGC is described, and bench and flight test results are presented. The AGC circuit described actually samples starting at a point 40 microseconds after a zero crossing determined by the software lock pulse ultimately generated by a 30 microsecond delay and add network in the receiver front end envelope detector.

  15. Automatic dose-rate controlling equipment

    International Nuclear Information System (INIS)

    Szasz, T.; Nagy Czirok, Cs.; Batki, L.; Antal, S.

    1977-01-01

    The patent of a dose-rate controlling equipment that can be attached to X-ray image-amplifiers is presented. In the new equipment the current of the photocatode of the image-amplifier is led into the regulating unit, which controls the X-ray generator automatically. The advantages of the equipment are the following: it can be simply attached to any type of X-ray image-amplifier, it accomplishes fast and sensitive regulation, it makes possible the control of both the mA and the kV values, it is attached to the most reliable point of the image-transmission chain. (L.E.)

  16. Computer Aided Automatic Control - CAAC artificial intelligence block

    Energy Technology Data Exchange (ETDEWEB)

    Balate, J.; Chramcov, B.; Princ, M. [Brno Univ. of Technology (Czech Republic). Faculty of Technology in Zlin

    2000-07-01

    The aim of the plan to build up the system CAAC - Computer Aided Automatic Control is to create modular setup of partial computing programs including theory of automatic control, algorithms of programs for processing signals and programs of control algorithms. To approach its informative contents to students and professional public the CAAC system utilizes Internet services http in the form of WWW pages. The CAAC system is being processed at the Institute of Automation and Control Technique of the Faculty of Technology in Zlin of the Brno University of Technology and is determined particularly for pedagogic purposes. Recently also the methods of artificial intelligence have been included to the open CAAC system and that is comprised in this article. (orig.)

  17. Randomized algorithms in automatic control and data mining

    CERN Document Server

    Granichin, Oleg; Toledano-Kitai, Dvora

    2015-01-01

    In the fields of data mining and control, the huge amount of unstructured data and the presence of uncertainty in system descriptions have always been critical issues. The book Randomized Algorithms in Automatic Control and Data Mining introduces the readers to the fundamentals of randomized algorithm applications in data mining (especially clustering) and in automatic control synthesis. The methods proposed in this book guarantee that the computational complexity of classical algorithms and the conservativeness of standard robust control techniques will be reduced. It is shown that when a problem requires "brute force" in selecting among options, algorithms based on random selection of alternatives offer good results with certain probability for a restricted time and significantly reduce the volume of operations.

  18. Dynamic Optimization of Feedforward Automatic Gauge Control Based on Extended Kalman Filter

    Institute of Scientific and Technical Information of China (English)

    YANG Bin-hu; YANG Wei-dong; CHEN Lian-gui; QU Lei

    2008-01-01

    Automatic gauge control is an essentially nonlinear process varying with time delay, and stochastically varying input and process noise always influence the target gauge control accuracy. To improve the control capability of feedforward automatic gauge control, Kalman filter was employed to filter the noise signal transferred from one stand to another. The linearized matrix that the Kalman filter algorithm needed was concluded; thus, the feedforward automatic gauge control architecture was dynamically optimized. The theoretical analyses and simulation show that the proposed algorithm is reasonable and effective.

  19. From the Conception to the Marketing of a New Automatic Control

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Kildegaard, Erik; Boel, Jan

    1985-01-01

    From a historical viewpoint, product technology has developed via radiator thermostats, return thermostats and selfacting automatic temperature and pressure controls towards more integrated automatic control systems also including weather compensators, which offer benefits in the form of energy...

  20. Investigation of an automatic trim algorithm for restructurable aircraft control

    Science.gov (United States)

    Weiss, J.; Eterno, J.; Grunberg, D.; Looze, D.; Ostroff, A.

    1986-01-01

    This paper develops and solves an automatic trim problem for restructurable aircraft control. The trim solution is applied as a feed-forward control to reject measurable disturbances following control element failures. Disturbance rejection and command following performances are recovered through the automatic feedback control redesign procedure described by Looze et al. (1985). For this project the existence of a failure detection mechanism is assumed, and methods to cope with potential detection and identification inaccuracies are addressed.

  1. Personal exposure control system

    International Nuclear Information System (INIS)

    Tanabe, Ken-ichi; Akashi, Michio

    1994-01-01

    Nuclear power stations are under strict radiation control. Exposure control for nuclear workers is the most important operation, and so carefully thought out measures are taken. This paper introduces Fuji Electric's personal exposure control system that meets strict exposure control and rationalizes control operations. The system has a merit that it can provide required information in an optimum form using the interconnection of a super minicomputer and exposure control facilities and realizes sophisticated exposure control operations. (author)

  2. On the systems of automatic non-destructive control of NPP metallic structures

    International Nuclear Information System (INIS)

    Grebennik, V.S.; Lantukh, V.M.

    1980-01-01

    The main stages of developing automatic systems of non- destructive control (NC) of NPP metallic structures are pointed out. The main requirements for automatic NC systems are formulated. Recommendations on the use of the developed experimental automatic facilities for control of certain NPP components are given. It is noted that the present facilities may be used in the future in development of modular sets of non-destructive control systems [ru

  3. CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study.

    Science.gov (United States)

    Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed

    2016-04-01

    To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. AUTOMATIC CONTROL SYSTEM OF WINTER AUTOMOBILE-ROAD MAINTENANCE

    Directory of Open Access Journals (Sweden)

    I. I. Leonovich

    2008-01-01

    Full Text Available In order to ensure a rational usage of financial and material resources directed on winter automobile-road maintenance in theRepublicofBelarusan automatic control system of winter maintenance is under its development and introduction.  The main purpose of the system is to obtain and use meteorological information on the state of a road network that allows to take necessary organizational and technological solutions ensuring safety and continuity of traffic during winter. This system also presupposes to ensure constant control over the state of roadway covering, expenditure of anti-glazed frost materials at all levels of management.The paper considers main aspects pertaining to introduction of the automatic control system of winter maintenance

  5. Tailoring automatic exposure control toward constant detectability in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Salvagnini, Elena, E-mail: elena.salvagnini@uzleuven.be [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Bosmans, Hilde [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Struelens, Lara [SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Marshall, Nicholas W. [Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium)

    2015-07-15

    Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively

  6. Tailoring automatic exposure control toward constant detectability in digital mammography.

    Science.gov (United States)

    Salvagnini, Elena; Bosmans, Hilde; Struelens, Lara; Marshall, Nicholas W

    2015-07-01

    The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. The default "opdose" AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d'), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (Tt) in the European guidelines for the 0.1 mm diameter disc (i.e., Tt ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (Tt), calculated detectability (d'), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. The default opdose AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d' 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d'), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default

  7. Discrete data processing from a scintillation sensor for exposure automatic machine in medical radiography

    International Nuclear Information System (INIS)

    Karadimov, D.; Petukhov, N.; Dimitrova, S.; Vasilev, M.

    1983-01-01

    An exposure automatic machine with a thin plastic scintillator plate collimated by light guide with a photoconverter is described. Due to the physical processes nature in the scintillator accounted by the photomultiplier there is a possibility of a radiation analysis as well as of a digital processing of the results. Two alternative devices are shown. In the first of them the photomultiplier output signal is fed to a pulse-height selector at the output of which standard logical level pulses are obtained. These pulses are fed to a data register and then to a digital comparator where they are compared with a preset quantity selected depending on X-ray film sensitivity and foil combinations as well as on the desired film darkening. The ionizing radiation interruption is controlled by a switch unit. The detector spectral sensitivity correction is accomplished changing the photomultiplier supply voltage. In the second alternative a noise and ionizing radiation discriminator is used where a pulse-height selection according to the radiant energy is carried out. A digital comparator and a switching circuit control the ionizing radiation. By a second switching circuit the spectral distributed pulses from the discriminator are fed to a spectral analyser controlling dinamically the digital comparator compensating for the ionizing radiation spectral response influence. The second alternative advantage is that it allows for the radiation parameters control both in radiograph mode and X-ray examination mode. Due to the system fast-acting the device can be used to measure very short exposures as well as in serial examinations

  8. Efficient Use of Automatic Exposure Control Systems in Computed Tomography Requires Correct Patient Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Gudjonsdottir, J.; Jonsdottir, B. (Roentgen Domus Medica, Reykjavik (Iceland)); Svensson, J.R.; Campling, S. (Faculty of Health and Social Care, Anglia Ruskin Univ., Cambridge (United Kingdom)); Brennan, P.C. (Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, Univ. College Dublin, Belfield, Dublin (Ireland))

    2009-11-15

    Background: Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. Purpose: To evaluate the effects of patient centering on tube current-time product (mAs) and image noise. Material and Methods: An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. Results: In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom (P<0.001), with correlation values of 0.98 for scanners A and B and -0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, -34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from -0.95 to -0.86 (P<0.02). In the x-direction, significant noise relationships (P<0.005) were only seen in scanner A. Conclusion: This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected

  9. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Seoul National University Medical Research Center, Institute of Radiation Medicine, Bundang (Korea, Republic of); Kim, Kil Joong [Seoul National University College of Medicine, Department of Radiation Applied Life Science, Seoul (Korea, Republic of); Kim, Bohyoung; Lee, Hyunna [Seoul National University, School of Computer Science and Engineering, Seoul (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Yanof, Jeffrey H. [Philips Healthcare, CT Clinical Science, Cleveland, OH (United States); Hwang, Seung-sik [Inha University School of Medicine, Department of Social and Preventive Medicine, Incheon (Korea, Republic of)

    2011-02-15

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI{sub vol}) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI{sub vol} and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI{sub vol} varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI{sub vol} and ATT (p = 0.61). ATT did not significantly affect CTDI{sub vol} (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI{sub vol} (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  10. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    International Nuclear Information System (INIS)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon; Kim, Kil Joong; Kim, Bohyoung; Lee, Hyunna; Park, Seong Ho; Yanof, Jeffrey H.; Hwang, Seung-sik

    2011-01-01

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI vol ) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI vol and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI vol varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI vol and ATT (p = 0.61). ATT did not significantly affect CTDI vol (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI vol (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  11. Norms concerning the programmable automatic control devices

    International Nuclear Information System (INIS)

    Fourmentraux, G.

    1995-01-01

    This presentation is a report of the studies carried out by the Work Group on Functioning Safety of Programmable Automatic Control Devices and by the Group for Prevention Studies (GEP) from the CEA. The objective of these groups is to evaluate the methods which could be used to estimate the functioning safety of control and instrumentation systems involved in the Important Elements for Safety (EIS) of the Basic Nuclear Installations (INB) of the CEA, and also to carry out a qualification of automatic control devices. Norms, protocols and tools for the evaluation are presented. The problem comprises two aspects: the evaluation of fault avoidance techniques and the evaluation of fault control techniques used during the conceiving. For the fault avoidance techniques, the quality assurance organization, the environment tests, and the software quality plans are considered. For the fault control techniques, the different available tools and fault injection models are analysed. The results of an analysis carried out with the DEF.I tool from the National Institute for Research and Safety (INRS) are reported. (J.S.). 23 refs

  12. Distributed automatic control of technological processes in conditions of weightlessness

    Science.gov (United States)

    Kukhtenko, A. I.; Merkulov, V. I.; Samoylenko, Y. I.; Ladikov-Royev, Y. P.

    1986-01-01

    Some problems associated with the automatic control of liquid metal and plasma systems under conditions of weightlessness are examined, with particular reference to the problem of stability of liquid equilibrium configurations. The theoretical fundamentals of automatic control of processes in electrically conducting continuous media are outlined, and means of using electromagnetic fields for simulating technological processes in a space environment are discussed.

  13. A rule-based expert system for control rod pattern of boiling water reactors by hovering around haling exposure shape

    International Nuclear Information System (INIS)

    Kao, P.-W.; Lin, L.-S.; Yang, J.-T.

    2004-01-01

    Feasible strategies for automatic BWR control rod pattern generation have been implemented in a rule-based expert system. These strategies are majorly based on a concept for which exposure distributions are hovering around the Haling exposure distribution through a cycle while radial and axial power distributions are dominantly controlled by some abstracted factors indicating the desired distributions. The system can either automatically generate expert-level control rod patterns or search for criteria-satisfied patterns originated from user's input. It has successfully been demonstrated by generating control rod patterns for the the 1775 MWth Chinshan plant in Unit I Cycle 13 alternate loading pattern and Unit 2 Cycle 8 but with longer cycle length. All rod patterns for two cycles result in all-rod-out at EOC and no violation against the four criteria. The demonstrations show that the system is considerably good in choosing initial trial rod patterns and adjusting rod patterns to satisfy the design criteria. (author)

  14. The role of automatic control in future interplanetary spaceflight

    Science.gov (United States)

    Scull, J. R.; Moore, J. W.

    1976-01-01

    The paper reviews the guidance and automatic control techniques used in previous U.S. and Soviet lunar and planetary exploration spacecraft, and examines the objectives and requirements of potential future interplanetary missions from the viewpoint of their further demands on automatic control technology. These missions include the Venus orbital imaging radar mission, the Pioneer Mars penetrator mission, the Mars surface sample return mission, Pioneer Saturn/Uranus/Titan probe missions, the Mariner Jupiter orbiter with daughter satellite, and comet and asteroid missions.

  15. Model study of an automatic controller of the IBR-2 pulsed reactor

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.; Popov, A.K.

    2007-01-01

    For calculation of power transients in the IBR-2 reactor a special mathematical model of dynamics taking into account the discontinuous jump of reactivity by an automatic controller with the step motor is created. In the model the nonlinear dependence of the energy of power pulse on the reactivity and the influence of warming up of the reactor on the reactivity by means of introduction of a nonlinear feedback 'power-pulse energy - reactivity' are taken into account. With the help of the model the transients of relative deviation of power-pulse energy are calculated at various (random, mixed and regular) reactivity disturbances at the reactor mean power 1.475 MW. It is shown that to improve the quality of processes the choice of such regular values of parameters of the automatic controller is expedient, at which the least effect of smoothing of a signal acting on an automatic controller and the least speed of an automatic controller are provided, and the reduction of efficiency of one step of the automatic controller and introduction of a five-percent dead space are also expedient

  16. An Evaluation of Automatic Control System Concepts for General Aviation Airplanes

    Science.gov (United States)

    Stewart, E. C.

    1990-01-01

    A piloted simulation study of automatic longitudinal control systems for general aviation airplanes has been conducted. These automatic control systems were designed to make the simulated airplane easy to fly for a beginning or infrequent pilot. Different control systems are presented and their characteristics are documented. In a conventional airplane control system each cockpit controller commands combinations of both the airspeed and the vertical speed. The best system in the present study decoupled the airspeed and vertical speed responses to cockpit controller inputs. An important feature of the automatic system was that neither changing flap position nor maneuvering in steeply banked turns affected either the airspeed or the vertical speed. All the pilots who flew the control system simulation were favorably impressed with the very low workload and the excellent handling qualities of the simulated airplane.

  17. 75 FR 59326 - Eighth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-09-27

    ... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The... Special Committee 220: Automatic Flight Guidance and Control meeting. The agenda will include: Welcome...

  18. Design of cylindrical pipe automatic welding control system based on STM32

    Science.gov (United States)

    Chen, Shuaishuai; Shen, Weicong

    2018-04-01

    The development of modern economy makes the demand for pipeline construction and construction rapidly increasing, and the pipeline welding has become an important link in pipeline construction. At present, there are still a large number of using of manual welding methods at home and abroad, and field pipe welding especially lacks miniature and portable automatic welding equipment. An automated welding system consists of a control system, which consisting of a lower computer control panel and a host computer operating interface, as well as automatic welding machine mechanisms and welding power systems in coordination with the control system. In this paper, a new control system of automatic pipe welding based on the control panel of the lower computer and the interface of the host computer is proposed, which has many advantages over the traditional automatic welding machine.

  19. A general digital computer procedure for synthesizing linear automatic control systems

    International Nuclear Information System (INIS)

    Cummins, J.D.

    1961-10-01

    The fundamental concepts required for synthesizing a linear automatic control system are considered. A generalized procedure for synthesizing automatic control systems is demonstrated. This procedure has been programmed for the Ferranti Mercury and the IBM 7090 computers. Details of the programmes are given. The procedure uses the linearized set of equations which describe the plant to be controlled as the starting point. Subsequent computations determine the transfer functions between any desired variables. The programmes also compute the root and phase loci for any linear (and some non-linear) configurations in the complex plane, the open loop and closed loop frequency responses of a system, the residues of a function of the complex variable 's' and the time response corresponding to these residues. With these general programmes available the design of 'one point' automatic control systems becomes a routine scientific procedure. Also dynamic assessments of plant may be carried out. Certain classes of multipoint automatic control problems may also be solved with these procedures. Autonomous systems, invariant systems and orthogonal systems may also be studied. (author)

  20. 76 FR 22163 - Tenth Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2011-04-20

    ... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220 meeting: Automatic Flight Guidance and Control. SUMMARY: The FAA is... hereby given for a Special Committee 220, Automatic Flight Guidance and Control. Agenda Tuesday May 10...

  1. 76 FR 38742 - Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2011-07-01

    ... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220 Meeting: Automatic Flight Guidance and Control. SUMMARY: The..., Automatic Flight Guidance and Control. Agenda Tuesday August 9-Thursday, August 11, 2011 Tuesday, August 9...

  2. 75 FR 15770 - Sixth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-03-30

    ... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is... hereby given for a Special Committee 220: Automatic Flight Guidance and Control meeting. The agenda will...

  3. 75 FR 80886 - Ninth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-12-23

    ... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is... for a Special Committee 220: Automatic Flight Guidance and Control meeting. The agenda will include...

  4. Automatic Control of Personal Rapid Transit Vehicles

    Science.gov (United States)

    Smith, P. D.

    1972-01-01

    The requirements for automatic longitudinal control of a string of closely packed personal vehicles are outlined. Optimal control theory is used to design feedback controllers for strings of vehicles. An important modification of the usual optimal control scheme is the inclusion of jerk in the cost functional. While the inclusion of the jerk term was considered, the effect of its inclusion was not sufficiently studied. Adding the jerk term will increase passenger comfort.

  5. A wide range and high speed automatic gain control

    International Nuclear Information System (INIS)

    Tacconi, E.; Christiansen, C.

    1993-05-01

    Automatic gain control (AGC) techniques have been largely used since the beginning of electronics, but in most of the applications the dynamic response is slow compared with the carrier frequency. The problem of developing an automatic gain control with high dynamic response and wide control range simultaneously is analyzed in this work. An ideal gain control law, with the property that the total loop gain remains constant independent of the carrier amplitude, is obtained. The resulting AGC behavior is compared by computer simulations with a linear multiplier AGC. The ideal gain control law can be approximated using a transconductance amplifier. A practical circuit that has been used at CERN in the radio frequency loops of the Booster Synchrotron is presented. The circuit has high speed and 80-dB gain control range

  6. On the centrality of disturbance rejection in automatic control.

    Science.gov (United States)

    Gao, Zhiqiang

    2014-07-01

    In this paper, it is shown that the problem of automatic control is, in essence, that of disturbance rejection, with the notion of disturbance generalized to symbolize the uncertainties, both internal and external to the plant. A novel, unifying concept of disturbance rejector is proposed to compliment the traditional notion of controller. The new controller-rejector pair is shown to be a powerful organizing principle in the realm of automatic control, leading to a Copernican moment where the model-centric design philosophy is replaced by the one that is control-centric in the following sense: the controller is designed for a canonical model and is fixed; the difference between the plant and the canonical model is deemed as disturbance and rejected. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  7. On a program manifold’s stability of one contour automatic control systems

    Directory of Open Access Journals (Sweden)

    Zumatov S. S.

    2017-12-01

    Full Text Available Methodology of analysis of stability is expounded to the one contour systems automatic control feedback in the presence of non-linearities. The methodology is based on the use of the simplest mathematical models of the nonlinear controllable systems. Stability of program manifolds of one contour automatic control systems is investigated. The sufficient conditions of program manifold’s absolute stability of one contour automatic control systems are obtained. The Hurwitz’s angle of absolute stability was determined. The sufficient conditions of program manifold’s absolute stability of control systems by the course of plane in the mode of autopilot are obtained by means Lyapunov’s second method.

  8. 76 FR 50809 - Eleventh Meeting: RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2011-08-16

    ... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Correction of Notice of RTCA Special Committee 220 meeting: Automatic Flight Guidance and Control...: Automatic Flight Guidance and Control DATES: The meeting will be held September 13-15, 2011, from 9 a.m. to...

  9. 75 FR 36471 - Seventh Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-06-25

    ... Committee 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The... Committee 220: Automatic Flight Guidance and [[Page 36472

  10. The research of automatic speed control algorithm based on Green CBTC

    Science.gov (United States)

    Lin, Ying; Xiong, Hui; Wang, Xiaoliang; Wu, Youyou; Zhang, Chuanqi

    2017-06-01

    Automatic speed control algorithm is one of the core technologies of train operation control system. It’s a typical multi-objective optimization control algorithm, which achieve the train speed control for timing, comfort, energy-saving and precise parking. At present, the train speed automatic control technology is widely used in metro and inter-city railways. It has been found that the automatic speed control technology can effectively reduce the driver’s intensity, and improve the operation quality. However, the current used algorithm is poor at energy-saving, even not as good as manual driving. In order to solve the problem of energy-saving, this paper proposes an automatic speed control algorithm based on Green CBTC system. Based on the Green CBTC system, the algorithm can adjust the operation status of the train to improve the efficient using rate of regenerative braking feedback energy while ensuring the timing, comfort and precise parking targets. Due to the reason, the energy-using of Green CBTC system is lower than traditional CBTC system. The simulation results show that the algorithm based on Green CBTC system can effectively reduce the energy-using due to the improvement of the using rate of regenerative braking feedback energy.

  11. Operating experience of the automatic technological control system at the Kolsk NPP

    International Nuclear Information System (INIS)

    Volkov, A.P.; Ignatenko, E.I.; Kolomtsev, Yu.V.; Mel'nikov, E.F.; Trofimov, B.A.

    1981-01-01

    Briefly reviewed is operating experience of the automatic control systems of the kolsk NPP (KNPP) power units, where measuring technique of the neutron flux ''Iney'', ARM-4 power regulator, automatic turbine start-up system ATS are used. The main shortcomings of the technological process automatic control system (ACS) and ways of their removal are considered. It is noted that the KNPP ACS performs only limited start-up functions of the basic equipment and reactor power control as well as partially protection functions at instant loading drops and switch-off of the main circulating pump [ru

  12. A bottom-up approach to automatically configured Tango control systems

    International Nuclear Information System (INIS)

    Rubio-Manrique, S.; Beltran, D.; Costa, I.; Fernandez-Carreiras, D.; Gigante, J.V.; Klora, J.; Matilla, O.; Ranz, R.; Ribas, J.; Sanchez, O.

    2012-01-01

    Alba is the first synchrotron light source built in Spain. Most of Alba control system has been developed on top of Tango control system. An amount of 5531 devices are controlled in Alba accelerators (linac, booster and storage ring) using 150 Linux PCs. Alba maintains a central repository, so called 'Cabling and Controls database' (CCDB), which keeps the inventory of equipment, cables, connections and their configuration and technical specifications. The valuable information kept in this MySQL database enables some tools to automatically create and configure Tango devices and other software components of the control systems of Accelerators, beamlines and laboratories. This paper describes the process involved in this automatic setup

  13. Automatic control study of the icing research tunnel refrigeration system

    Science.gov (United States)

    Kieffer, Arthur W.; Soeder, Ronald H.

    1991-01-01

    The Icing Research Tunnel (IRT) at the NASA Lewis Research Center is a subsonic, closed-return atmospheric tunnel. The tunnel includes a heat exchanger and a refrigeration plant to achieve the desired air temperature and a spray system to generate the type of icing conditions that would be encountered by aircraft. At the present time, the tunnel air temperature is controlled by manual adjustment of freon refrigerant flow control valves. An upgrade of this facility calls for these control valves to be adjusted by an automatic controller. The digital computer simulation of the IRT refrigeration plant and the automatic controller that was used in the simulation are discussed.

  14. Performance of an automatic dose control system for CT. Patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Stumpp, P.; Gosch, D.; Kuehn, A.; Sorge, I.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Weber, D. [St. Elisabeth-Krankenhaus Leipzig (Germany). Roentgendiagnostik; Lehmkuhl, L. [Leipzig Univ. - Herzzentrum (Germany). Diagnostische und Interventionelle Radiologie; Nagel, H.D. [Dr. HD Nagel, Wissenschaft und Technik fuer die Radiologie, Buchholz (Germany)

    2013-02-15

    Purpose: To study the effect of an automatic dose control (ADC) system with adequate noise characteristic on the individual perception of image noise and diagnostic acceptance compared to objectively measured image noise and the dose reductions achieved in a representative group of patients. Materials and Methods: In a retrospective study two matched cohorts of 20 patients each were identified: a manual cohort with exposure settings according to body size (small - regular - large) and an ADC cohort with exposure settings calculated by the ADC system (DoseRight 2.0 trademark, Philips Healthcare). For each patient, 12 images from 6 defined anatomic levels from contrast-enhanced scans of chest and abdomen/pelvis were analyzed by 4 independent readers concerning image noise and diagnostic acceptance on a five-point Likert scale and evaluated for objectively measured image noise. Radiation exposure was calculated from recorded exposure data. Results: Use of the ADC system reduced the average effective dose for patients by 36 % in chest scans (3.2 vs. 4.9 mSv) and by 17 % in abdomen/pelvis scans (7.6 vs. 8.3 mSv). Average objective noise was slightly lower in the manual cohort (11.1 vs. 12.8 HU), correlating with a slightly better rating in subjective noise score (4.4 vs. 4.2). However, diagnostic acceptance was rated almost equal in both cohorts with excellent image quality (4.6 vs. 4.5). Conclusion: Use of an ADC system with adequate noise characteristic leads to significant reductions in radiation exposure for patients while maintaining excellent image quality. (orig.)

  15. Evaluation of automatic face recognition for automatic border control on actual data recorded of travellers at Schiphol Airport

    NARCIS (Netherlands)

    Spreeuwers, Lieuwe Jan; Hendrikse, A.J.; Gerritsen, K.J.; Brömme, A.; Busch, C.

    2012-01-01

    Automatic border control at airports using automated facial recognition for checking the passport is becoming more and more common. A problem is that it is not clear how reliable these automatic gates are. Very few independent studies exist that assess the reliability of automated facial recognition

  16. Research on automatic control system of greenhouse

    Science.gov (United States)

    Liu, Yi; Qi, Guoyang; Li, Zeyu; Wu, Qiannan; Meng, Yupeng

    2017-03-01

    This paper introduces a kind of automatic control system of single-chip microcomputer and a temperature and humidity sensor based on the greenhouse, describes the system's hardware structure, working principle and process, and a large number of experiments on the effect of the control system, the results show that the system can ideally control temperature and room temperature and humidity, can be used in indoor breeding and planting, and has the versatility and portability.

  17. Automatic Generation of Wide Dynamic Range Image without Pseudo-Edge Using Integration of Multi-Steps Exposure Images

    Science.gov (United States)

    Migiyama, Go; Sugimura, Atsuhiko; Osa, Atsushi; Miike, Hidetoshi

    Recently, digital cameras are offering technical advantages rapidly. However, the shot image is different from the sight image generated when that scenery is seen with the naked eye. There are blown-out highlights and crushed blacks in the image that photographed the scenery of wide dynamic range. The problems are hardly generated in the sight image. These are contributory cause of difference between the shot image and the sight image. Blown-out highlights and crushed blacks are caused by the difference of dynamic range between the image sensor installed in a digital camera such as CCD and CMOS and the human visual system. Dynamic range of the shot image is narrower than dynamic range of the sight image. In order to solve the problem, we propose an automatic method to decide an effective exposure range in superposition of edges. We integrate multi-step exposure images using the method. In addition, we try to erase pseudo-edges using the process to blend exposure values. Afterwards, we get a pseudo wide dynamic range image automatically.

  18. Design of Control System for Kiwifruit Automatic Grading Machine

    Directory of Open Access Journals (Sweden)

    Xingjian Zuo

    2013-05-01

    Full Text Available The kiwifruit automatic grading machine is an important machine for postharvest processing of kiwifruit, and the control system ensures that the machine realizes intelligence. The control system for the kiwifruit automatic grading machine designed in this paper comprises a host computer and a slave microcontroller. The host computer provides a visual grading interface for the machine with a LabVIEW software, the slave microcontroller adopts an STC89C52 microcontroller as its core, and C language is used to write programs for controlling a position sensor module, push-pull type electromagnets, motor driving modules and a power supply for controlling the operation of the machine as well as the rise or descend of grading baffle plates. The ideal control effect is obtained through test, and the intelligent operation of the machine is realized.

  19. Automatic control system for the pig ion source for the U-400 cyclotron

    International Nuclear Information System (INIS)

    Kutner, V.B.; Subbotin, V.G.; Sukhov, A.M.; Tret'yakov, Yu.P.; Fefilov, B.V.

    1989-01-01

    An automatic control system is described for the cyclotron U-400 multiply-charged ion source based on CAMAC apparatus and microprocesor controllers. The system allows the automatic tuning of the ion source to the necessary regime including the automatic start-up of discharge, the obtaining of the necessary parameters of sputtering, the automatic search for a maximum beam current within the given discharge parameters. The system performs tuning the ion source to the quasioptimal regime for 10-15 minutes with up to 5% deviation from the preset parameters. It is possible to stabilize the beam current within 3% using the automatic correction of the discharge regime. 6 refs.; 4 figs

  20. Automatic control system of the PIG ion source for the U-400 cyclotron

    International Nuclear Information System (INIS)

    Kutner, V.B.; Subbotin, V.G.; Sukhov, A.M.; Tretyakov, Y.P.; Fefilov, B.V.; Kasyanov, A.A.; Rybin, V.M.

    1990-01-01

    An automatic control system is described for the multiply charged ion source of the U-400 cyclotron based on CAMAC apparatus and microprocessor controllers. The system allows the automatic tuning of the ion source to the necessary regime, including the automatic start-up of discharge, determination of the necessary parameters of sputtering, and the automatic search for a maximum beam current for given discharge parameters. The system performs the tuning of the ion source to the quasioptimal regime in 10--15 min with up to 5% deviation from the preset parameters. It is possible to stabilize the beam current within 3% using the automatic correction of the discharge regime

  1. Quasiinvariant Automatic Control Digital Systems of Inertia Objects

    OpenAIRE

    Lvov, Volodymyr; Andrieiev, Anatoliy

    2010-01-01

    The two-connected automatic control digital system (ACDS) and system of ACDS with combined control are examined. The two-connected and combined system of ACDS with work in the mode of tracking and stabilizing are analyzed. The discrete transfer function of two-connected and combined systems are obtained.

  2. A Network of Automatic Control Web-Based Laboratories

    Science.gov (United States)

    Vargas, Hector; Sanchez Moreno, J.; Jara, Carlos A.; Candelas, F. A.; Torres, Fernando; Dormido, Sebastian

    2011-01-01

    This article presents an innovative project in the context of remote experimentation applied to control engineering education. Specifically, the authors describe their experience regarding the analysis, design, development, and exploitation of web-based technologies within the scope of automatic control. This work is part of an inter-university…

  3. A manual-control approach to development of VTOL automatic landing technology.

    Science.gov (United States)

    Kelly, J. R.; Niessen, F. R.; Garren, J. F., Jr.

    1973-01-01

    The operation of VTOL aircraft in the city-center environment will require complex landing-approach trajectories that insure adequate clearance from other traffic and obstructions and provide the most direct routing for efficient operations. As part of a larger program to develop the necessary technology base, a flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings. The study employed a three-cue flight director driven by control laws developed and refined during manual-control studies and subsequently applied to the automatic approach problem. The validity of this approach was demonstrated by performing the first automatic approach and landings to a predetermined spot ever accomplished with a helicopter. The manual-control studies resulted in the development of a constant-attitude deceleration profile and a low-noise navigation system.

  4. 75 FR 3959 - Fifth Meeting-RTCA Special Committee 220: Automatic Flight Guidance and Control

    Science.gov (United States)

    2010-01-25

    ... 220: Automatic Flight Guidance and Control AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 220: Automatic Flight Guidance and Control meeting. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 220: Automatic Flight...

  5. Research on automatic correction of electronic beam path for distributed control

    International Nuclear Information System (INIS)

    Guo Xin; Su Haijun; Li Deming; Wang Shengli; Guo Honglei

    2014-01-01

    Background: Dynamitron, an electron irradiation accelerator of high-voltage, is used as a radiation source for industrial and agricultural production. The control system is an important component of dynamitron. Purpose: The aim is to improve the control system to meet the performance requirements of dynamitron for the stability. Methods: A distributed control system for the 1.5-MeV dynamitron is proposed to gain better performance. On this basis, an electron beam trajectory automatic correction method based on Cerebellar Model Articulation Controller and Proportional-Integral Derivative (CMAC-PID) controller is designed to improve the function of electron beam extraction system. Results: The distributed control system can meet the control requirements of the accelerator. The stability of the CMAC PID controller is better than that of conventional PID controller for the electron beam trajectory automatic correction system, and hence the CMAC-PID controller can provide better protection of dynamitron when electron beam deflection occurs. Conclusion: The distributed control system and the electron beam trajectory automatic correction method system can effectively improve the performance and reduce the failure probability of the accelerator, thereby enhancing the efficiency of the accelerator. (authors)

  6. A price based automatic generation control using unscheduled ...

    African Journals Online (AJOL)

    In this paper, a model for price based automatic generation control is presented. A modified control scheme is proposed which will prevent unintended unscheduled interchanges among the participants. The proposed scheme is verified by simulating it on a model of isolated area system having four generators. It has been ...

  7. Choosing Actuators for Automatic Control Systems of Thermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Gorbunov, A. I., E-mail: gor@tornado.nsk.ru [JSC “Tornado Modular Systems” (Russian Federation); Serdyukov, O. V. [Siberian Branch of the Russian Academy of Sciences, Institute of Automation and Electrometry (Russian Federation)

    2015-03-15

    Two types of actuators for automatic control systems of thermal power plants are analyzed: (i) pulse-controlled actuator and (ii) analog-controlled actuator with positioning function. The actuators are compared in terms of control circuit, control accuracy, reliability, and cost.

  8. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  9. Automatic control of cryogenic wind tunnels

    Science.gov (United States)

    Balakrishna, S.

    1989-01-01

    Inadequate Reynolds number similarity in testing of scaled models affects the quality of aerodynamic data from wind tunnels. This is due to scale effects of boundary-layer shock wave interaction which is likely to be severe at transonic speeds. The idea of operation of wind tunnels using test gas cooled to cryogenic temperatures has yielded a quantrum jump in the ability to realize full scale Reynolds number flow similarity in small transonic tunnels. In such tunnels, the basic flow control problem consists of obtaining and maintaining the desired test section flow parameters. Mach number, Reynolds number, and dynamic pressure are the three flow parameters that are usually required to be kept constant during the period of model aerodynamic data acquisition. The series of activity involved in modeling, control law development, mechanization of the control laws on a microcomputer, and the performance of a globally stable automatic control system for the 0.3-m Transonic Cryogenic Tunnel (TCT) are discussed. A lumped multi-variable nonlinear dynamic model of the cryogenic tunnel, generation of a set of linear control laws for small perturbation, and nonlinear control strategy for large set point changes including tunnel trajectory control are described. The details of mechanization of the control laws on a 16 bit microcomputer system, the software features, operator interface, the display and safety are discussed. The controller is shown to provide globally stable and reliable temperature control to + or - 0.2 K, pressure to + or - 0.07 psi and Mach number to + or - 0.002 of the set point value. This performance is obtained both during large set point commands as for a tunnel cooldown, and during aerodynamic data acquisition with intrusive activity like geometrical changes in the test section such as angle of attack changes, drag rake movements, wall adaptation and sidewall boundary-layer removal. Feasibility of the use of an automatic Reynolds number control mode with

  10. Dissociation between controlled and automatic processes in the behavioral variant of fronto-temporal dementia.

    Science.gov (United States)

    Collette, Fabienne; Van der Linden, Martial; Salmon, Eric

    2010-01-01

    A decline of cognitive functioning affecting several cognitive domains was frequently reported in patients with frontotemporal dementia. We were interested in determining if these deficits can be interpreted as reflecting an impairment of controlled cognitive processes by using an assessment tool specifically developed to explore the distinction between automatic and controlled processes, namely the process dissociation procedure (PDP) developed by Jacoby. The PDP was applied to a word stem completion task to determine the contribution of automatic and controlled processes to episodic memory performance and was administered to a group of 12 patients with the behavioral variant of frontotemporal dementia (bv-FTD) and 20 control subjects (CS). Bv-FTD patients obtained a lower performance than CS for the estimates of controlled processes, but no group differences was observed for estimates of automatic processes. The between-groups comparison of the estimates of controlled and automatic processes showed a larger contribution of automatic processes to performance in bv-FTD, while a slightly more important contribution of controlled processes was observed in control subjects. These results are clearly indicative of an alteration of controlled memory processes in bv-FTD.

  11. Study on automatic control of high uranium concentration solvent extraction with pulse sieve-plate column

    International Nuclear Information System (INIS)

    You Wenzhi; Xing Guangxuan; Long Maoxiong; Zhang Jianmin; Zhou Qin; Chen Fuping; Ye Lingfeng

    1998-01-01

    The author mainly described the working condition of the automatic control system of high uranium concentration solvent extraction with pulse sieve-plate column on a large scale test. The use of the automatic instrument and meter, automatic control circuit, and the best feedback control point of the solvent extraction processing with pulse sieve-plate column are discussed in detail. The writers point out the success of this experiment on automation, also present some questions that should be cared for the automatic control, instruments and meters in production in the future

  12. METHODS OF AUTOMATIC QUALITY CONTROL OF AGGLUTINANTSANDS IN FOUNDRY

    Directory of Open Access Journals (Sweden)

    D. M. Kukuj

    2004-01-01

    Full Text Available The article is dedicated to comparative analysis of the well-known methods of automatic quality control of agglutinant sands in process of their preparation and to the problems of automation control of the mix preparation processes.

  13. Effect of automatic control technologies on emission reduction in small-scale combustion

    Energy Technology Data Exchange (ETDEWEB)

    Ruusunen, M. [Control Engineering Laboratory, University of Oulu (Finland)

    2007-07-01

    Automatic control can be regarded as a primary measure for preventing combustion emissions. In this view, the control technology covers broadly the control methods, sensors and actuators for monitoring and controlling combustion. In addition to direct control of combustion process, it can also give tools for condition monitoring and optimisation of total heat consumption by system integration thus reducing the need for excess conversion of energy. Automatic control has already shown its potential in small-scale combustion. The potential, but still unrealised advantages of automatic control in this scale are the adaptation to changes in combustion conditions (fuel, environment, device, user) and the continuous optimisation of the air/fuel ratio. Modem control technology also covers combustion condition monitoring, diagnostics, and the higher level optimisation of the energy consumption with system integration. In theory, these primary measures maximise the overall efficiency, enabling a significant reduction in fuel consumption and thus total emissions per small-scale combustion unit, specifically at the annual level.

  14. A method of automatic data processing in radiometric control

    International Nuclear Information System (INIS)

    Adonin, V.M.; Gulyukina, N.A.; Nemirov, Yu.V.; Mogil'nitskij, M.I.

    1980-01-01

    Described is the algorithm for automatic data processing in gamma radiography of products. Rapidity due to application of recurrent evaluation is a specific feature of the processing. Experimental data of by-line control are presented. The results obtained have shown the applicability of automatic signal processing to the testing under industrial conditions, which would permit to increase the testing efficiency to eliminate the subjectivism in assessment of testing results and to improve working conditions

  15. Virtual reality exposure treatment of agoraphobia: a comparison of computer automatic virtual environment and head-mounted display

    NARCIS (Netherlands)

    Meyerbröker, K.; Morina, N.; Kerkhof, G.; Emmelkamp, P.M.G.; Wiederhold, B.K.; Bouchard, S.; Riva, G.

    2011-01-01

    In this study the effects of virtual reality exposure therapy (VRET) were investigated in patients with panic disorder and agoraphobia. The level of presence in VRET was compared between using either a head-mounted display (HMD) or a computer automatic virtual environment (CAVE). Results indicate

  16. Automatic start-up system of nuclear reactor based on sequence control technology

    International Nuclear Information System (INIS)

    Zhang Yao; Zhang Dafa; Peng Huaqing

    2009-01-01

    A conceptive design of an automatic start-up system based on the sequence control for the nuclear reactors is given in this paper, so as to solve the problems during the start-up process, such as the long operation time, low automatic control level and high accident rate. The start-up process and its requirements are analyzed in detail at first. Then,the principle, the architecture, the key technologies of the automatic start-up system of nuclear reactors are designed and discussed. With the designed system, the automatic start-up of the nuclear reactor can be realized,the work load of the operator can be reduced,and the safety and efficiency of the nuclear power plant during its start-up can be improved. (authors)

  17. Realization of the ergonomics design and automatic control of the fundus cameras

    Science.gov (United States)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  18. Automatic process control in anaerobic digestion technology: A critical review.

    Science.gov (United States)

    Nguyen, Duc; Gadhamshetty, Venkataramana; Nitayavardhana, Saoharit; Khanal, Samir Kumar

    2015-10-01

    Anaerobic digestion (AD) is a mature technology that relies upon a synergistic effort of a diverse group of microbial communities for metabolizing diverse organic substrates. However, AD is highly sensitive to process disturbances, and thus it is advantageous to use online monitoring and process control techniques to efficiently operate AD process. A range of electrochemical, chromatographic and spectroscopic devices can be deployed for on-line monitoring and control of the AD process. While complexity of the control strategy ranges from a feedback control to advanced control systems, there are some debates on implementation of advanced instrumentations or advanced control strategies. Centralized AD plants could be the answer for the applications of progressive automatic control field. This article provides a critical overview of the available automatic control technologies that can be implemented in AD processes at different scales. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Design of electric control system for automatic vegetable bundling machine

    Science.gov (United States)

    Bao, Yan

    2017-06-01

    A design can meet the requirements of automatic bale food structure and has the advantages of simple circuit, and the volume is easy to enhance the electric control system of machine carrying bunch of dishes and low cost. The bundle of vegetable machine should meet the sensor to detect and control, in order to meet the control requirements; binding force can be adjusted by the button to achieve; strapping speed also can be adjusted, by the keys to set; sensors and mechanical line connection, convenient operation; can be directly connected with the plug, the 220V power supply can be connected to a power source; if, can work, by the transmission signal sensor, MCU to control the motor, drive and control procedures for small motor. The working principle of LED control circuit and temperature control circuit is described. The design of electric control system of automatic dish machine.

  20. Automatic control logics to eliminate xenon oscillation based on Axial Offsets Trajectory Method

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    1996-01-01

    We have proposed Axial Offsets (AO) Trajectory Method for xenon oscillation control in pressurized water reactors. The features of this method are described as such that it can clearly give necessary control operations to eliminate xenon oscillations. It is expected that using the features automatic control logics for xenon oscillations can be simple and be realized easily. We investigated automatic control logics. The AO Trajectory Method could realize a very simple logic only for eliminating xenon oscillations. However it was necessary to give another considerations to eliminate the xenon oscillation with a given axial power distribution. The other control logic based on the modern control theory was also studied for comparison of the control performance of the new control logic. As the results, it is presented that the automatic control logics based on the AO Trajectory Method are very simple and effective. (author)

  1. Towards Automatic Controller Design using Multi-Objective Evolutionary Algorithms

    DEFF Research Database (Denmark)

    Pedersen, Gerulf

    of evolutionary computation, a choice was made to use multi-objective algorithms for the purpose of aiding in automatic controller design. More specifically, the choice was made to use the Non-dominated Sorting Genetic Algorithm II (NSGAII), which is one of the most potent algorithms currently in use...... for automatic controller design. However, because the field of evolutionary computation is relatively unknown in the field of control engineering, this thesis also includes a comprehensive introduction to the basic field of evolutionary computation as well as a description of how the field has previously been......In order to design the controllers of tomorrow, a need has risen for tools that can aid in the design of these. A desire to use evolutionary computation as a tool to achieve that goal is what gave inspiration for the work contained in this thesis. After having studied the foundations...

  2. Automatic Incubator-type Temperature Control System for Brain Hypothermia Treatment

    Science.gov (United States)

    Gaohua, Lu; Wakamatsu, Hidetoshi

    An automatic air-cooling incubator is proposed to replace the manual water-cooling blanket to control the brain tissue temperature for brain hypothermia treatment. Its feasibility is theoretically discussed as follows: First, an adult patient with the cooling incubator is modeled as a linear dynamical patient-incubator biothermal system. The patient is represented by an 18-compartment structure and described by its state equations. The air-cooling incubator provides almost same cooling effect as the water-cooling blanket, if a light breeze of speed around 3 m/s is circulated in the incubator. Then, in order to control the brain temperature automatically, an adaptive-optimal control algorithm is adopted, while the patient-blanket therapeutic system is considered as a reference model. Finally, the brain temperature of the patient-incubator biothermal system is controlled to follow up the given reference temperature course, in which an adaptive algorithm is confirmed useful for unknown environmental change and/or metabolic rate change of the patient in the incubating system. Thus, the present work ensures the development of the automatic air-cooling incubator for a better temperature regulation of the brain hypothermia treatment in ICU.

  3. UIO-based Fault Diagnosis for Hydraulic Automatic Gauge Control System of Magnesium Sheet Mill

    Directory of Open Access Journals (Sweden)

    Li-Ping FAN

    2014-02-01

    Full Text Available Hydraulic automatic gauge control system of magnesium sheet mill is a complex integrated control system, which including mechanical, hydraulic and electrical comprehensive information. The failure rate of AGC system always is high, and its fault reasons are always complex. Based on analyzing the fault of main components of the automatic gauge control system, unknown input observer is used to realize fault diagnosis and isolation. Simulation results show that the fault diagnosis method based on the unknown input observer for the hydraulic automatic gauge control system of magnesium sheet mill is effective.

  4. 5th International Conference on Electrical Engineering and Automatic Control

    CERN Document Server

    Yao, Yufeng

    2016-01-01

    On the basis of instrument electrical and automatic control system, the 5th International Conference on Electrical Engineering and Automatic Control (CEEAC) was established at the crossroads of information technology and control technology, and seeks to effectively apply information technology to a sweeping trend that views control as the core of intelligent manufacturing and life. This book takes a look forward into advanced manufacturing development, an area shaped by intelligent manufacturing. It highlights the application and promotion of process control represented by traditional industries, such as the steel industry and petrochemical industry; the technical equipment and system cooperative control represented by robot technology and multi-axis CNC; and the control and support of emerging process technologies represented by laser melting and stacking, as well as the emerging industry represented by sustainable and intelligent life. The book places particular emphasis on the micro-segments field, such as...

  5. Plasma automatic control in magnetic traps

    International Nuclear Information System (INIS)

    Samojlenko, Yu.I.; Chuyanov, V.A.

    1983-01-01

    Principles of constructing the systems providing a plasma equilibrium and stability in thermonuctear devices are laid down. Operation of the servo system to maintain a plasma equilibrium is described using the tokamak plasma filament as an example. Operation of the system to suppress a flute instability is also described. This system measures electric disturbances on the plasma body surface and controls charge distribution on external electrodes. It is pointed out that systems of automatic control of plasma equilibrium and stability become an essential element of a future thermonuclear reactor and the system potentialities would much determine the reactor economic efficiency

  6. Tracking control mechanisms for positioning automatic CRD exchanger

    International Nuclear Information System (INIS)

    Koizumi, Akira; Takada, Satoshi.

    1984-01-01

    Purpose: To enable completely automatic positioning for the automatic CRD (control rod drives) exchanger, as well as shorten the time for the exchanging operation and save the operator's labour. Constitution: Images of a target attached to the lower flange face of CRD are picked up by a fiber scope mounted to a mounting head. The images are converted through I.T.V. into electrical signals, passed through a cable and then sent to a pattern recognition mechanism. The position for the images of the target is calculated and the calculated position is sent to a drive control section, where the position for the images of the target is compared with a reference position for the images (exactly aligned position) and the moving amount of the mounting head is calculated to move the driving section and thereby complete the positioning. (Kawakami, Y.)

  7. Implicit proactive interference, age, and automatic versus controlled retrieval strategies.

    Science.gov (United States)

    Ikier, Simay; Yang, Lixia; Hasher, Lynn

    2008-05-01

    We assessed the extent to which implicit proactive interference results from automatic versus controlled retrieval among younger and older adults. During a study phase, targets (e.g., "ALLERGY") either were or were not preceded by nontarget competitors (e.g., "ANALOGY"). After a filled interval, the participants were asked to complete word fragments, some of which cued studied words (e.g., "A_L_ _GY"). Retrieval strategies were identified by the difference in response speed between a phase containing fragments that cued only new words and a phase that included a mix of fragments cuing old and new words. Previous results were replicated: Proactive interference was found in implicit memory, and the negative effects were greater for older than for younger adults. Novel findings demonstrate two retrieval processes that contribute to interference: an automatic one that is age invariant and a controlled process that can reduce the magnitude of the automatic interference effects. The controlled process, however, is used effectively only by younger adults. This pattern of findings potentially explains age differences in susceptibility to proactive interference.

  8. Automatic section cutting and forming control of longitudinal-axial-roadheaders

    Energy Technology Data Exchange (ETDEWEB)

    Jie Tian; Yang Yang; Guo-Qiang Chen; Hong-Yao Wang; Jian-Gong Liu; Miao Wu [China University of Mining and Technology (Beijing), Beijing (China). School of Mechanical, Electronic and Information Engineering

    2009-01-15

    To reduce the useless driving workload and volume of filling and improve excavating efficiency, a method of laneway section automatic forming control of longitudinal-axial-roadheaders was presented. Firstly, a mine laneway section automatic cutting process was developed according to actual conditions of a coal mine. Then, a kinematic analysis was carried out of the automatic section forming control, including analysis of the swing mechanism, the spatial position of the cutting head and a geometric analysis of its mechanical structure. The geometrical relationship formulas were worked out between the cutter head spatial position coordinate, expansion increment of the hydraulic cylinders and swinging angles of the cantilever. The results show that the control mode of directly measuring swing angles of the cutting head is more simple and effective. The method proposed was put in practice in EBZ160 and EBZ200 boom-type roadheaders and the effect of experiment is very good, laying a foundation for further study on position detection and direction correction of roadheader. 11 refs., 5 figs., 1 tab.

  9. Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose?

    Science.gov (United States)

    Prakash, Priyanka; Gilman, Matthew D.; Shepard, Jo-Anne O.; Digumarthy, Subba R.

    2010-01-01

    Objective To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. Materials and Methods With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Results Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). Conclusion The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. PMID:20046494

  10. Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose?

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, Priyanka; Kalra, Mannudeep K.; Gilman, Matthew D.; Shepard, Jo Anne O.; Digumarthy, Subba R. [Massachusetts General Hospital and Harvard Medical School, Boston (United States)

    2010-02-15

    To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and nonweight- adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 {+-} 3.1) and weight-adjusted (16.1 {+-} 5.6) AEC techniques (p > 0.05). The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT.

  11. Experience with automatic reactor control at EBR-II

    International Nuclear Information System (INIS)

    Lehto, W.K.; Larson, H.A.; Christensen, L.J.

    1985-01-01

    Satisfactory operation of the ACRDS has extended the capabilities of EBR-II to a transient test facility, achieving automatic transient control. Test assemblies can now be irradiated in transient conditions overlapping the slower transient capability of the TREAT reactor

  12. Microcontroller based automatic temperature control for oyster mushroom plants

    Science.gov (United States)

    Sihombing, P.; Astuti, T. P.; Herriyance; Sitompul, D.

    2018-03-01

    In the cultivation of Oyster Mushrooms need special treatment because oyster mushrooms are susceptible to disease. Mushroom growth will be inhibited if the temperature and humidity are not well controlled because temperature and inertia can affect mold growth. Oyster mushroom growth usually will be optimal at temperatures around 22-28°C and humidity around 70-90%. This problem is often encountered in the cultivation of oyster mushrooms. Therefore it is very important to control the temperature and humidity of the room of oyster mushroom cultivation. In this paper, we developed an automatic temperature monitoring tool in the cultivation of oyster mushroom-based Arduino Uno microcontroller. We have designed a tool that will control the temperature and humidity automatically by Android Smartphone. If the temperature increased more than 28°C in the room of mushroom plants, then this tool will turn on the pump automatically to run water in order to lower the room temperature. And if the room temperature of mushroom plants below of 22°C, then the light will be turned on in order to heat the room. Thus the temperature in the room oyster mushrooms will remain stable so that the growth of oyster mushrooms can grow with good quality.

  13. Study of structure of marine specialist activity in an ergative system on monitoring and managing automatic control parameters of safe navigation process

    Directory of Open Access Journals (Sweden)

    Kholichev S. N.

    2016-12-01

    Full Text Available The study of structures' common features and dynamics of the technical object tuning circuit performing automatic adjustment of safe navigation options has been conducted for the first time in the theory of ergative systems. The research of the structure and process of ergative system functioning including an automatic control system with the option of safe navigation conditions has been fulfilled. The function of signals' selection performing optimal control law reconfiguration of the mentioned system has been given, and some sequence of marine specialist activities allowing solve the problem of navigation safety has been composed. The ergative system retargeted by the ship specialist has a two-tier hierarchy. The first level is an automatic control of the safe navigation parameter, and the second is the level of reconfiguration where the ship specialist changes the parameters of regulation act. The two-level hierarchical representation of the ergative navigation security settings management system makes it possible to introduce the concept of reconfiguration of regulation level as ship specialist activity which is to reduce the uncertainty in the environment in the operation of this layer. Such a reduction can be achieved as a result of exposure to the upper level associated with ideas of the ship specialist on the regulation of safe navigation parameters of the vessel on the lower level – the level of direct control automatic safe navigation option. As a result of studying the activities of the ship specialist in the ergative system on monitoring and managing automatic control parameters of safe navigation process it has been found that the main task of the ship specialist in the operation within the ergative system ensuring the navigation safety is to monitor the input and output of the automatic control system, decisions on the choice of reconfiguration laws regulating signal on the basis of information about deviations and the

  14. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.

    Science.gov (United States)

    Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B

    1997-01-01

    An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.

  15. Scheduling algorithms for automatic control systems for technological processes

    Science.gov (United States)

    Chernigovskiy, A. S.; Tsarev, R. Yu; Kapulin, D. V.

    2017-01-01

    Wide use of automatic process control systems and the usage of high-performance systems containing a number of computers (processors) give opportunities for creation of high-quality and fast production that increases competitiveness of an enterprise. Exact and fast calculations, control computation, and processing of the big data arrays - all of this requires the high level of productivity and, at the same time, minimum time of data handling and result receiving. In order to reach the best time, it is necessary not only to use computing resources optimally, but also to design and develop the software so that time gain will be maximal. For this purpose task (jobs or operations), scheduling techniques for the multi-machine/multiprocessor systems are applied. Some of basic task scheduling methods for the multi-machine process control systems are considered in this paper, their advantages and disadvantages come to light, and also some usage considerations, in case of the software for automatic process control systems developing, are made.

  16. Experimental investigation of an accelerometer controlled automatic braking system

    Science.gov (United States)

    Dreher, R. C.; Sleeper, R. K.; Nayadley, J. R., Sr.

    1972-01-01

    An investigation was made to determine the feasibility of an automatic braking system for arresting the motion of an airplane by sensing and controlling braked wheel decelerations. The system was tested on a rotating drum dynamometer by using an automotive tire, wheel, and disk-brake assembly under conditions which included two tire loadings, wet and dry surfaces, and a range of ground speeds up to 70 knots. The controlling parameters were the rates at which brake pressure was applied and released and the Command Deceleration Level which governed the wheel deceleration by controlling the brake operation. Limited tests were also made with the automatic braking system installed on a ground vehicle in an effort to provide a more realistic proof of its feasibility. The results of this investigation indicate that a braking system which utilizes wheel decelerations as the control variable to restrict tire slip is feasible and capable of adapting to rapidly changing surface conditions.

  17. Dose to population as a metric in the design of optimised exposure control in digital mammography

    International Nuclear Information System (INIS)

    Klausz, R.; Shramchenko, N.

    2005-01-01

    This paper describes a methods for automatic optimisation of parameter (AOP) in digital mammography systems. Using a model of the image chain, contrast to noise ratio (CNR) and average glandular dose (AGD) are computed for possible X-ray parameters and breast types. The optimisation process consists of the determination of the operating points providing the lowest possible AGD for each CNR level and breast type. The proposed metric for the dose used in the design of an AOP mode is the resulting dose to the population, computed by averaging the AGD values over the distribution of breast types in the population. This method has been applied to the automatic exposure control of new digital mammography equipment. Breast thickness and composition are estimated from a low dose pre-exposure and used to index tables containing sets of optimised operating points. The resulting average dose to the population ranges from a level comparable to state-of-the-art screen/film mammography to a reduction by a factor of two. Using this method, both CNR and dose are kept under control for all breast types, taking into consideration both individual and collective risk. (authors)

  18. ANALYSIS OF EXISTING AND PROSPECTIVE TECHNICAL CONTROL SYSTEMS OF NUMERIC CODES AUTOMATIC BLOCKING

    Directory of Open Access Journals (Sweden)

    A. M. Beznarytnyy

    2013-09-01

    Full Text Available Purpose. To identify the characteristic features of the engineering control measures system of automatic block of numeric code, identifying their advantages and disadvantages, to analyze the possibility of their use in the problems of diagnosing status of the devices automatic block and setting targets for the development of new diagnostic systems. Methodology. In order to achieve targets the objective theoretical and analytical method and the method of functional analysis have been used. Findings. The analysis of existing and future facilities of the remote control and diagnostics automatic block devices had shown that the existing systems of diagnosis were not sufficiently informative, designed primarily to control the discrete parameters, which in turn did not allow them to construct a decision support subsystem. In developing of new systems of technical diagnostics it was proposed to use the principle of centralized distributed processing of diagnostic data, to include a subsystem support decision-making in to the diagnostics system, it will reduce the amount of work to maintain the devices blocking and reduce recovery time after the occurrence injury. Originality. As a result, the currently existing engineering controls facilities of automatic block can not provide a full assessment of the state distillation alarms and locks. Criteria for the development of new systems of technical diagnostics with increasing amounts of diagnostic information and its automatic analysis were proposed. Practical value. These results of the analysis can be used in practice in order to select the technical control of automatic block devices, as well as the further development of diagnostic systems automatic block that allows for a gradual transition from a planned preventive maintenance service model to the actual state of the monitored devices.

  19. Automatic control algorithm effects on energy production

    Science.gov (United States)

    Mcnerney, G. M.

    1981-01-01

    A computer model was developed using actual wind time series and turbine performance data to simulate the power produced by the Sandia 17-m VAWT operating in automatic control. The model was used to investigate the influence of starting algorithms on annual energy production. The results indicate that, depending on turbine and local wind characteristics, a bad choice of a control algorithm can significantly reduce overall energy production. The model can be used to select control algorithms and threshold parameters that maximize long term energy production. The results from local site and turbine characteristics were generalized to obtain general guidelines for control algorithm design.

  20. Data-driven automatic parking constrained control for four-wheeled mobile vehicles

    Directory of Open Access Journals (Sweden)

    Wenxu Yan

    2016-11-01

    Full Text Available In this article, a novel data-driven constrained control scheme is proposed for automatic parking systems. The design of the proposed scheme only depends on the steering angle and the orientation angle of the car, and it does not involve any model information of the car. Therefore, the proposed scheme-based automatic parking system is applicable to different kinds of cars. In order to further reduce the desired trajectory coordinate tracking errors, a coordinates compensation algorithm is also proposed. In the design procedure of the controller, a novel dynamic anti-windup compensator is used to deal with the change magnitude and rate saturations of automatic parking control input. It is theoretically proven that all the signals in the closed-loop system are uniformly ultimately bounded based on Lyapunov stability analysis method. Finally, a simulation comparison among the proposed scheme with coordinates compensation and Proportion Integration Differentiation (PID control algorithm is given. It is shown that the proposed scheme with coordinates compensation has smaller tracking errors and more rapid responses than PID scheme.

  1. Automatic control of a negative ion source

    International Nuclear Information System (INIS)

    Saadatmand, K.; Sredniawski, J.; Solensten, L.

    1989-01-01

    A CAMAC based control architecture is devised for a Berkeley-type H - volume ion source. The architecture employs three 80386 PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived. (orig.)

  2. Automatic control of a negative ion source

    Science.gov (United States)

    Saadatmand, K.; Sredniawski, J.; Solensten, L.

    1989-04-01

    A CAMAC based control architecture is devised for a Berkeley-type H - volume ion source [1]. The architecture employs three 80386 TM PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived.

  3. Automatic control of a negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Saadatmand, K.; Sredniawski, J.; Solensten, L. (Grumman Corp., Long Island, NY (USA))

    1989-04-01

    A CAMAC based control architecture is devised for a Berkeley-type H/sup -/ volume ion source. The architecture employs three 80386 PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived. (orig.).

  4. Effects of voluntary and automatic control of center of pressure sway during quiet standing.

    Science.gov (United States)

    Ueta, Kozo; Okada, Yohei; Nakano, Hideki; Osumi, Michihiro; Morioka, Shu

    2015-01-01

    The authors investigated the effects of voluntary and automatic control on the spatial variables (envelope area, maximal amplitude, and root mean square [RMS]) of center of pressure (COP) displacement during quiet standing and identified differences in their postural control strategies (mean velocity [MV], mean power frequency [MPF], and power density). COP data were recorded under relaxed (experimental control), still (voluntary control), and dual (automatic control) conditions. RMS was significantly lower in the still and dual conditions than in the relaxed condition. MV, MPF, and power density were significantly higher in the still condition than in the dual condition. These results indicate that both voluntary and automatic control decrease the spatial variables of COP displacement; however, their postural control strategies are different.

  5. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  6. Automatic Offline Formulation of Robust Model Predictive Control Based on Linear Matrix Inequalities Method

    Directory of Open Access Journals (Sweden)

    Longge Zhang

    2013-01-01

    Full Text Available Two automatic robust model predictive control strategies are presented for uncertain polytopic linear plants with input and output constraints. A sequence of nested geometric proportion asymptotically stable ellipsoids and controllers is constructed offline first. Then the feedback controllers are automatically selected with the receding horizon online in the first strategy. Finally, a modified automatic offline robust MPC approach is constructed to improve the closed system's performance. The new proposed strategies not only reduce the conservatism but also decrease the online computation. Numerical examples are given to illustrate their effectiveness.

  7. Automatic Design of a Maglev Controller in State Space

    Science.gov (United States)

    1991-12-01

    Design of a Maglev Controller in State Space Feng Zhao Richard Thornton Abstract We describe the automatic synthesis of a global nonlinear controller for...the global switching points of the controller is presented. The synthesized control system can stabilize the maglev vehicle with large initial displace...NUMBERS Automation Desing of a Maglev Controller in State Space N00014-89-J-3202 MIP-9001651 6. AUTHOR(S) Feng Zhao and Richard Thornton 7. PERFORMING

  8. General collaboration offer of Johnson Controls regarding the performance of air conditioning automatic control systems and other buildings` automatic control systems

    Energy Technology Data Exchange (ETDEWEB)

    Gniazdowski, J.

    1995-12-31

    JOHNSON CONTROLS manufactures measuring and control equipment (800 types) and is as well a {open_quotes}turn-key{close_quotes} supplier of complete automatic controls systems for heating, air conditioning, ventilation and refrigerating engineering branches. The Company also supplies Buildings` Computer-Based Supervision and Monitoring Systems that may be applied in both small and large structures. Since 1990 the company has been performing full-range trade and contracting activities on the Polish market. We have our own well-trained technical staff and we collaborate with a series of designing and contracting enterprises that enable us to have our projects carried out all over Poland. The prices of our supplies and services correspond with the level of the Polish market.

  9. AUTOMATIC CONTROL SYSTEM ОF REGIONAL BOILER HOUSE

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2005-01-01

    Full Text Available Implementation of an automatic control system is one of directions that promotes to increase an operational efficiency of a heat supply system. A heating boiler house in Surgut (Russia is taken as an example to demonstrate an actual realization of such system.

  10. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  11. Path Tracking Control of Automatic Parking Cloud Model considering the Influence of Time Delay

    Directory of Open Access Journals (Sweden)

    Yiding Hua

    2017-01-01

    Full Text Available This paper establishes the kinematic model of the automatic parking system and analyzes the kinematic constraints of the vehicle. Furthermore, it solves the problem where the traditional automatic parking system model fails to take into account the time delay. Firstly, based on simulating calculation, the influence of time delay on the dynamic trajectory of a vehicle in the automatic parking system is analyzed under the transverse distance Dlateral between different target spaces. Secondly, on the basis of cloud model, this paper utilizes the tracking control of an intelligent path closer to human intelligent behavior to further study the Cloud Generator-based parking path tracking control method and construct a vehicle path tracking control model. Moreover, tracking and steering control effects of the model are verified through simulation analysis. Finally, the effectiveness and timeliness of automatic parking controller in the aspect of path tracking are tested through a real vehicle experiment.

  12. Automatic Synthesis of Robust and Optimal Controllers

    DEFF Research Database (Denmark)

    Cassez, Franck; Jessen, Jan Jacob; Larsen, Kim Guldstrand

    2009-01-01

    In this paper, we show how to apply recent tools for the automatic synthesis of robust and near-optimal controllers for a real industrial case study. We show how to use three different classes of models and their supporting existing tools, Uppaal-TiGA for synthesis, phaver for verification......, and Simulink for simulation, in a complementary way. We believe that this case study shows that our tools have reached a level of maturity that allows us to tackle interesting and relevant industrial control problems....

  13. Electronic circuit provides automatic level control for liquid nitrogen traps

    Science.gov (United States)

    Turvy, R. R.

    1968-01-01

    Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

  14. Development of a cerebral circulation model for the automatic control of brain physiology.

    Science.gov (United States)

    Utsuki, T

    2015-01-01

    In various clinical guidelines of brain injury, intracranial pressure (ICP), cerebral blood flow (CBF) and brain temperature (BT) are essential targets for precise management for brain resuscitation. In addition, the integrated automatic control of BT, ICP, and CBF is required for improving therapeutic effects and reducing medical costs and staff burden. Thus, a new model of cerebral circulation was developed in this study for integrative automatic control. With this model, the CBF and cerebral perfusion pressure of a normal adult male were regionally calculated according to cerebrovascular structure, blood viscosity, blood distribution, CBF autoregulation, and ICP. The analysis results were consistent with physiological knowledge already obtained with conventional studies. Therefore, the developed model is potentially available for the integrative control of the physiological state of the brain as a reference model of an automatic control system, or as a controlled object in various control simulations.

  15. Neural Correlates of Automatic and Controlled Auditory Processing in Schizophrenia

    Science.gov (United States)

    Morey, Rajendra A.; Mitchell, Teresa V.; Inan, Seniha; Lieberman, Jeffrey A.; Belger, Aysenil

    2009-01-01

    Individuals with schizophrenia demonstrate impairments in selective attention and sensory processing. The authors assessed differences in brain function between 26 participants with schizophrenia and 17 comparison subjects engaged in automatic (unattended) and controlled (attended) auditory information processing using event-related functional MRI. Lower regional neural activation during automatic auditory processing in the schizophrenia group was not confined to just the temporal lobe, but also extended to prefrontal regions. Controlled auditory processing was associated with a distributed frontotemporal and subcortical dysfunction. Differences in activation between these two modes of auditory information processing were more pronounced in the comparison group than in the patient group. PMID:19196926

  16. Use of reactivity constraints for the automatic control of reactor power

    International Nuclear Information System (INIS)

    Bernard, J.A.; Lanning, D.D.; Ray, A.

    1985-01-01

    A theoretical framework for the automatic control of reactor power has been developed and experimentally evaluated on the 5 MWt Research Reactor that is operated by the Massachusetts Institute of Technology. The controller functions by restricting the net reactivity so that it is always possible to make the reactor period infinite at the desired termination point of a transient by reversing the direction of motion of whatever control mechanism is associated with the controller. This capability is formally designated as ''feasibility of control''. It has been shown experimentally that maintenance of feasibility of control is a sufficient condition for the automatic control of reactor power. This research should be of value in the design of closed-loop controllers, in the creation of reactivity displays, in the provision of guidance to operators regarding the timing of reactivity changes, and as an experimental envelope within which alternate control strategies can be evaluated

  17. PLC based automatic control of pasteurize mix in ice cream production

    Science.gov (United States)

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  18. Automatic micropart assembly of 3-Dimensional structure by vision based control

    International Nuclear Information System (INIS)

    Wang, Lidai; Kim, Seung Min

    2008-01-01

    We propose a vision control strategy to perform automatic microassembly tasks in three-dimension (3-D) and develop relevant control software: specifically, using a 6 degree-of-freedom (DOF) robotic workstation to control a passive microgripper to automatically grasp a designated micropart from the chip, pivot the micropart, and then move the micropart to be vertically inserted into a designated slot on the chip. In the proposed control strategy, the whole microassembly task is divided into two subtasks, micro-grasping and micro-joining, in sequence. To guarantee the success of microassembly and manipulation accuracy, two different two-stage feedback motion strategies, the pattern matching and auto-focus method are employed, with the use of vision-based control system and the vision control software developed. Experiments conducted demonstrate the efficiency and validity of the proposed control strategy

  19. Automatic micropart assembly of 3-Dimensional structure by vision based control

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lidai [University of Toronto, Toronto (Canada); Kim, Seung Min [Korean Intellectual Property Office, Daejeon (Korea, Republic of)

    2008-12-15

    We propose a vision control strategy to perform automatic microassembly tasks in three-dimension (3-D) and develop relevant control software: specifically, using a 6 degree-of-freedom (DOF) robotic workstation to control a passive microgripper to automatically grasp a designated micropart from the chip, pivot the micropart, and then move the micropart to be vertically inserted into a designated slot on the chip. In the proposed control strategy, the whole microassembly task is divided into two subtasks, micro-grasping and micro-joining, in sequence. To guarantee the success of microassembly and manipulation accuracy, two different two-stage feedback motion strategies, the pattern matching and auto-focus method are employed, with the use of vision-based control system and the vision control software developed. Experiments conducted demonstrate the efficiency and validity of the proposed control strategy

  20. A GA-fuzzy automatic generation controller for interconnected power system

    CSIR Research Space (South Africa)

    Boesack, CD

    2011-10-01

    Full Text Available This paper presents a GA-Fuzzy Automatic Generation Controller for large interconnected power systems. The design of Fuzzy Logic Controllers by means of expert knowledge have typically been the traditional design norm, however, this may not yield...

  1. Computer applications: Automatic control system for high-voltage accelerator

    International Nuclear Information System (INIS)

    Bryukhanov, A.N.; Komissarov, P.Yu.; Lapin, V.V.; Latushkin, S.T.. Fomenko, D.E.; Yudin, L.I.

    1992-01-01

    An automatic control system for a high-voltage electrostatic accelerator with an accelerating potential of up to 500 kV is described. The electronic apparatus on the high-voltage platform is controlled and monitored by means of a fiber-optic data-exchange system. The system is based on CAMAC modules that are controlled by a microprocessor crate controller. Data on accelerator operation are represented and control instructions are issued by means of an alphanumeric terminal. 8 refs., 6 figs

  2. Automatic Tuning of PID Controller for a 1-D Levitation System Using a Genetic Algorithm

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Pedersen, Gerulf K.m.

    2006-01-01

    The automatic PID control design for a onedimensional magnetic levitation system is investigated. The PID controller is automatically tuned using the non-dominated sorting genetic algorithm (NSGA-II) based on a nonlinear system model. The developed controller is digitally implemented and tested...

  3. Automatic Reverse Engineering of Private Flight Control Protocols of UAVs

    Directory of Open Access Journals (Sweden)

    Ran Ji

    2017-01-01

    Full Text Available The increasing use of civil unmanned aerial vehicles (UAVs has the potential to threaten public safety and privacy. Therefore, airspace administrators urgently need an effective method to regulate UAVs. Understanding the meaning and format of UAV flight control commands by automatic protocol reverse-engineering techniques is highly beneficial to UAV regulation. To improve our understanding of the meaning and format of UAV flight control commands, this paper proposes a method to automatically analyze the private flight control protocols of UAVs. First, we classify flight control commands collected from a binary network trace into clusters; then, we analyze the meaning of flight control commands by the accumulated error of each cluster; next, we extract the binary format of commands and infer field semantics in these commands; and finally, we infer the location of the check field in command and the generator polynomial matrix. The proposed approach is validated via experiments on a widely used consumer UAV.

  4. Development of a digital guidance and control law for steep approach automatic landings using modern control techniques

    Science.gov (United States)

    Halyo, N.

    1979-01-01

    The development of a digital automatic control law for a small jet transport to perform a steep final approach in automatic landings is reported along with the development of a steady-state Kalman filter used to provide smooth estimates to the control law. The control law performs the functions of localizer and glides capture, localizer and glideslope track, decrab, and place. The control law uses the microwave landing system position data, and aircraft body-mounted accelerators, attitude and attitude rate information. The results obtained from a digital simulation of the aircraft dynamics, wind conditions, and sensor noises using the control law and filter developed are described.

  5. Uranium casting furnace automatic temperature control development

    International Nuclear Information System (INIS)

    Lind, R.F.

    1992-01-01

    Development of an automatic molten uranium temperature control system for use on batch-type induction casting furnaces is described. Implementation of a two-color optical pyrometer, development of an optical scanner for the pyrometer, determination of furnace thermal dynamics, and design of control systems are addressed. The optical scanning system is shown to greatly improve pyrometer measurement repeatability, particularly where heavy floating slag accumulations cause surface temperature gradients. Thermal dynamics of the furnaces were determined by applying least-squares system identification techniques to actual production data. A unity feedback control system utilizing a proportional-integral-derivative compensator is designed by using frequency-domain techniques. 14 refs

  6. Automatic synthesis of sequential control schemes

    International Nuclear Information System (INIS)

    Klein, I.

    1993-01-01

    Of all hard- and software developed for industrial control purposes, the majority is devoted to sequential, or binary valued, control and only a minor part to classical linear control. Typically, the sequential parts of the controller are invoked during startup and shut-down to bring the system into its normal operating region and into some safe standby region, respectively. Despite its importance, fairly little theoretical research has been devoted to this area, and sequential control programs are therefore still created manually without much theoretical support to obtain a systematic approach. We propose a method to create sequential control programs automatically. The main ideas is to spend some effort off-line modelling the plant, and from this model generate the control strategy, that is the plan. The plant is modelled using action structures, thereby concentrating on the actions instead of the states of the plant. In general the planning problem shows exponential complexity in the number of state variables. However, by focusing on the actions, we can identify problem classes as well as algorithms such that the planning complexity is reduced to polynomial complexity. We prove that these algorithms are sound, i.e., the generated solution will solve the stated problem, and complete, i.e., if the algorithms fail, then no solution exists. The algorithms generate a plan as a set of actions and a partial order on this set specifying the execution order. The generated plant is proven to be minimal and maximally parallel. For a larger class of problems we propose a method to split the original problem into a number of simple problems that can each be solved using one of the presented algorithms. It is also shown how a plan can be translated into a GRAFCET chart, and to illustrate these ideas we have implemented a planing tool, i.e., a system that is able to automatically create control schemes. Such a tool can of course also be used on-line if it is fast enough. This

  7. Software and hardware platform for testing of Automatic Generation Control algorithms

    Directory of Open Access Journals (Sweden)

    Vasiliev Alexey

    2017-01-01

    Full Text Available Development and implementation of new Automatic Generation Control (AGC algorithms requires testing them on a model that adequately simulates primary energetic, information and control processes. In this article an implementation of a test platform based on HRTSim (Hybrid Real Time Simulator and SCADA CK-2007 (which is widely used by the System Operator of Russia is proposed. Testing of AGC algorithms on the test platform based on the same SCADA system that is used in operation allows to exclude errors associated with the transfer of AGC algorithms and settings from the test platform to a real power system. A power system including relay protection, automatic control systems and emergency control automatics can be accurately simulated on HRTSim. Besides the information commonly used by conventional AGC systems HRTSim is able to provide a resemblance of Phasor Measurement Unit (PMU measurements (information about rotor angles, magnitudes and phase angles of currents and voltages etc.. The additional information significantly expands the number of possible AGC algorithms so the test platform is useful in modern AGC system developing. The obtained test results confirm that the proposed system is applicable for the tasks mentioned above.

  8. Automatic control of a primary electric thrust subsystem

    Science.gov (United States)

    Macie, T. W.; Macmedan, M. L.

    1975-01-01

    A concept for automatic control of the thrust subsystem has been developed by JPL and participating NASA Centers. This paper reports on progress in implementing the concept at JPL. Control of the Thrust Subsystem (TSS) is performed by the spacecraft computer command subsystem, and telemetry data is extracted by the spacecraft flight data subsystem. The Data and Control Interface Unit, an element of the TSS, provides the interface with the individual elements of the TSS. The control philosophy and implementation guidelines are presented. Control requirements are listed, and the control mechanism, including the serial digital data intercommunication system, is outlined. The paper summarizes progress to Fall 1974.

  9. The design of control algorithm for automatic start-up model of HWRR

    International Nuclear Information System (INIS)

    Guo Wenqi

    1990-01-01

    The design of control algorithm for automatic start-up model of HWRR (Heavy Water Research Reactor), the calculation of μ value and the application of digital compensator are described. Finally The flow diagram of the automatic start-up and digital compensator program for HWRR are given

  10. Automatic Control of ITER-like Structures

    International Nuclear Information System (INIS)

    Bosia, G.; Bremond, S.

    2005-01-01

    In ITER Ion Cyclotron System requires a power transfer efficiency in excess of 90% from power source to plasma in quasi continuous operation. This implies the availability of a control system capable of optimizing the array radiation spectrum, automatically acquiring impedance match between the power source and the plasma loaded array at the beginning of the power pulse and maintaining it against load variations due to plasma position and plasma edge parameters fluctuations, rapidly detecting voltage breakdowns in the array and/or in the transmission system and reliably discriminating them from fast load variations. In this paper a proposal for a practical ITER control system, including power, phase, frequency and impedance matching is described. (authors)

  11. Wide-range nuclear reactor temperature control using automatically tuned fuzzy logic controller

    International Nuclear Information System (INIS)

    Ramaswamy, P.; Edwards, R.M.; Lee, K.Y.

    1992-01-01

    In this paper, a fuzzy logic controller design for optimal reactor temperature control is presented. Since fuzzy logic controllers rely on an expert's knowledge of the process, they are hard to optimize. An optimal controller is used in this paper as a reference model, and a Kalman filter is used to automatically determine the rules for the fuzzy logic controller. To demonstrate the robustness of this design, a nonlinear six-delayed-neutron-group plant is controlled using a fuzzy logic controller that utilizes estimated reactor temperatures from a one-delayed-neutron-group observer. The fuzzy logic controller displayed good stability and performance robustness characteristics for a wide range of operation

  12. Development and implementation of an automatic control algorithm for the University of Utah nuclear reactor

    International Nuclear Information System (INIS)

    Crawford, Kevan C.; Sandquist, Gary M.

    1990-01-01

    The emphasis of this work is the development and implementation of an automatic control philosophy which uses the classical operational philosophies as a foundation. Three control algorithms were derived based on various simplifying assumptions. Two of the algorithms were tested in computer simulations. After realizing the insensitivity of the system to the simplifications, the most reduced form of the algorithms was implemented on the computer control system at the University of Utah (UNEL). Since the operational philosophies have a higher priority than automatic control, they determine when automatic control may be utilized. Unlike the operational philosophies, automatic control is not concerned with component failures. The object of this philosophy is the movement of absorber rods to produce a requested power. When the current power level is compared to the requested power level, an error may be detected which will require the movement of a control rod to correct the error. The automatic control philosophy adds another dimension to the classical operational philosophies. Using this philosophy, normal operator interactions with the computer would be limited only to run parameters such as power, period, and run time. This eliminates subjective judgements, objective judgements under pressure, and distractions to the operator and insures the reactor will be operated in a safe and controlled manner as well as providing reproducible operations

  13. Artificial neural network controller for automatic ship berthing using head-up coordinate system

    Directory of Open Access Journals (Sweden)

    Nam-Kyun Im

    2018-05-01

    Full Text Available The Artificial Neural Network (ANN model has been known as one of the most effective theories for automatic ship berthing, as it has learning ability and mimics the actions of the human brain when performing the stages of ship berthing. However, existing ANN controllers can only bring a ship into a berth in a certain port, where the inputs of the ANN are the same as those of the teaching data. This means that those ANN controllers must be retrained when the ship arrives to a new port, which is time-consuming and costly. In this research, by using the head-up coordinate system, which includes the relative bearing and distance from the ship to the berth, a novel ANN controller is proposed to automatically control the ship into the berth in different ports without retraining the ANN structure. Numerical simulations were performed to verify the effectiveness of the proposed controller. First, teaching data were created in the original port to train the neural network; then, the controller was tested for automatic berthing in other ports, where the initial conditions of the inputs in the head-up coordinate system were similar to those of the teaching data in the original port. The results showed that the proposed controller has good performance for ship berthing in ports. Keywords: Automatic ship berthing, ANN controller, Head-up coordinate system, Low speed, Relative bearing

  14. Automatic control unit for A neutron diffraction crystal spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer.

  15. MATHEMATICAL AND COMPUTER MODELING OF AUTOMATIC CONTROL SYSTEM FOR HYDROSTATIC BEARING

    Directory of Open Access Journals (Sweden)

    N. A. Pelevin

    2016-09-01

    Full Text Available The paper presents simulation results of hydrostatic bearing dynamics in spindle assembly of standard flexible production module with throttled circuit. The necessity of dynamic quality increase for automatic control system of the hydrostatic bearing with the use of correcting means in the form of RC-chains is shown. The features of correction parameters choice coming from the existence of the crossing connections in automatic control system structure are noted. We propose the block diagram of automatic control system of the hydrostatic bearing in Simulink working field and cyclic algorithm for determination program of RC-chain parameters implemented in MATLAB taking into account typical thermal processes for the finishing treatment. Graphic-analytical method for the correction parameters choice is presented based on the stability stock phase gradient for dynamic quality determination of automatic control system. Researches of the method estimability in case of using the standard metal bellow valve as the hydrocapacity for RC-chain are also carried out. Recommendations for the bellow valve choice are formulated. The check of dynamic quality indicators concerning transition processes calculated by means of the appropriate programs developed for MATLAB is performed. Examples are given for phase stability factor gradient schedules with partition of various areas of hydrostatic bearing dynamic quality for different frequencies of spindle rotation and procedure description of data cursor function application on MATLAB toolbar. Improvement of hydrostatic bearing dynamics under typical low loadings for finishing treatment is noted. Also, decrease of dynamic indicators for high loadings treatment in case of roughing treatment is marked.

  16. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  17. Prediction Governors for Input-Affine Nonlinear Systems and Application to Automatic Driving Control

    Directory of Open Access Journals (Sweden)

    Yuki Minami

    2018-04-01

    Full Text Available In recent years, automatic driving control has attracted attention. To achieve a satisfactory driving control performance, the prediction accuracy of the traveling route is important. If a highly accurate prediction method can be used, an accurate traveling route can be obtained. Despite the considerable efforts that have been invested in improving prediction methods, prediction errors do occur in general. Thus, a method to minimize the influence of prediction errors on automatic driving control systems is required. This need motivated us to focus on the design of a mechanism for shaping prediction signals, which is called a prediction governor. In this study, we first extended our previous study to the input-affine nonlinear system case. Then, we analytically derived a solution to an optimal design problem of prediction governors. Finally, we applied the solution to an automatic driving control system, and demonstrated its usefulness through a numerical example and an experiment using a radio controlled car.

  18. 14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)

    Science.gov (United States)

    2010-01-01

    ... Appendix I to Part 25—Installation of an Automatic Takeoff Thrust Control System (ATTCS) I25.1General. (a... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Installation of an Automatic Takeoff Thrust...

  19. ISS Contingency Attitude Control Recovery Method for Loss of Automatic Thruster Control

    Science.gov (United States)

    Bedrossian, Nazareth; Bhatt, Sagar; Alaniz, Abran; McCants, Edward; Nguyen, Louis; Chamitoff, Greg

    2008-01-01

    In this paper, the attitude control issues associated with International Space Station (ISS) loss of automatic thruster control capability are discussed and methods for attitude control recovery are presented. This scenario was experienced recently during Shuttle mission STS-117 and ISS Stage 13A in June 2007 when the Russian GN&C computers, which command the ISS thrusters, failed. Without automatic propulsive attitude control, the ISS would not be able to regain attitude control after the Orbiter undocked. The core issues associated with recovering long-term attitude control using CMGs are described as well as the systems engineering analysis to identify recovery options. It is shown that the recovery method can be separated into a procedure for rate damping to a safe harbor gravity gradient stable orientation and a capability to maneuver the vehicle to the necessary initial conditions for long term attitude hold. A manual control option using Soyuz and Progress vehicle thrusters is investigated for rate damping and maneuvers. The issues with implementing such an option are presented and the key issue of closed-loop stability is addressed. A new non-propulsive alternative to thruster control, Zero Propellant Maneuver (ZPM) attitude control method is introduced and its rate damping and maneuver performance evaluated. It is shown that ZPM can meet the tight attitude and rate error tolerances needed for long term attitude control. A combination of manual thruster rate damping to a safe harbor attitude followed by a ZPM to Stage long term attitude control orientation was selected by the Anomaly Resolution Team as the alternate attitude control method for such a contingency.

  20. Automatic Control of Gene Expression in Mammalian Cells.

    Science.gov (United States)

    Fracassi, Chiara; Postiglione, Lorena; Fiore, Gianfranco; di Bernardo, Diego

    2016-04-15

    Automatic control of gene expression in living cells is paramount importance to characterize both endogenous gene regulatory networks and synthetic circuits. In addition, such a technology can be used to maintain the expression of synthetic circuit components in an optimal range in order to ensure reliable performance. Here we present a microfluidics-based method to automatically control gene expression from the tetracycline-inducible promoter in mammalian cells in real time. Our approach is based on the negative-feedback control engineering paradigm. We validated our method in a monoclonal population of cells constitutively expressing a fluorescent reporter protein (d2EYFP) downstream of a minimal CMV promoter with seven tet-responsive operator motifs (CMV-TET). These cells also constitutively express the tetracycline transactivator protein (tTA). In cells grown in standard growth medium, tTA is able to bind the CMV-TET promoter, causing d2EYFP to be maximally expressed. Upon addition of tetracycline to the culture medium, tTA detaches from the CMV-TET promoter, thus preventing d2EYFP expression. We tested two different model-independent control algorithms (relay and proportional-integral (PI)) to force a monoclonal population of cells to express an intermediate level of d2EYFP equal to 50% of its maximum expression level for up to 3500 min. The control input is either tetracycline-rich or standard growth medium. We demonstrated that both the relay and PI controllers can regulate gene expression at the desired level, despite oscillations (dampened in the case of the PI controller) around the chosen set point.

  1. Wallac automatic alarm dosimeter type RAD21

    International Nuclear Information System (INIS)

    Burgess, P. H.; Iles, W.J.

    1980-02-01

    The Automatic Alarm Dosimeter type RAD 21 is a batterypowered personal dosemeter and exposure rate alarm monitor, designed to be worn on the body, covering an exposure range from 0.1 to 999.9 mR and has an audible alarm which can be pre-set over the range 1 mR h -1 to 250 mR h -1 . The instrument is designed to measure x- and γ radiation over the energy range 50 keV to 3 MeV. The facilities and controls, the radiation, electrical, environmental and mechanical characteristics, and the manual, have been evaluated. (U.K.)

  2. On the application of bezier surfaces for GA-Fuzzy controller design for use in automatic generation control

    CSIR Research Space (South Africa)

    Boesack, CD

    2012-03-01

    Full Text Available Automatic Generation Control (AGC) of large interconnected power systems are typically controlled by a PI or PID type control law. Recently intelligent control techniques such as GA-Fuzzy controllers have been widely applied within the power...

  3. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Spadavecchia, Chiara [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Veronese, Ivan [Universita degli Studi di Milano, Dipartimento di Fisica, Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Cantone, Marie Claire [Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Milano (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Department of Biomedical Science for Health, San Donato Milanese (Italy)

    2017-07-15

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  4. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Zanardo, Moreno; Secchi, Francesco; Spadavecchia, Chiara; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-01-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. (orig.)

  5. Robust Fallback Scheme for the Danish Automatic Voltage Control System

    DEFF Research Database (Denmark)

    Qin, Nan; Dmitrova, Evgenia; Lund, Torsten

    2015-01-01

    This paper proposes a fallback scheme for the Danish automatic voltage control system. It will be activated in case of the local station loses telecommunication to the control center and/or the local station voltage violates the acceptable operational limits. It cuts in/out switchable and tap...... power system....

  6. An examination of automatic exposure control regimes for two digital radiography systems

    International Nuclear Information System (INIS)

    Marshall, N W

    2009-01-01

    The influence of two methods of an automatic exposure control (AEC) setup using a simple measure of detectability is examined as a function of x-ray beam quality for a computed radiography (CR) system and for an indirect conversion digital radiography (DR) system. The regimes assessed were constant air kerma at the detector and the constant contrast noise ratio (CNR). A low scatter geometry was employed with x-ray spectra varying from 60 kV and 1 mm Cu to 125 kV and 2 mm Cu. The CNR was measured using a 2 mm thick Al square of dimension 1 cm by 1 cm. Detectability was quantified via a nominal contrast for a fixed beam quality of 70 kV and 1 mm added Cu filtration, taken from c-d curves measured using the Leeds TO20 test object, for the four x-ray spectra. In addition, objective image quality parameters including modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) were also measured for both systems at the four different x-ray spectra. It was found that the constant air kerma strategy did not maintain threshold nominal contrast (simple detectability) constant as the x-ray beam mean energy increased, for either the CR system or the DR system. For the CR detector, the threshold nominal contrast for a 1 mm disc increased by a factor of 4.4 from 3.50% to 15.4% as the tube potential was raised from 60 kV to 125 kV, while for the DR detector, the threshold nominal contrast increased by a factor of 3.4, from 2.27% to 7.67% as the tube potential increased from 60 kV to 120 kV. The constant CNR method was more successful at maintaining constant detectability for the c-d discs. The threshold nominal contrast for the 1 mm disc changed by a factor of 1.2, from 4.80% to 5.70% for the CR system, as the spectrum changed from 60 kV to 125 kV. For the indirect conversion detector, the threshold nominal contrast increased from 2.27% to 5.66% (a factor of 1.4 increase). The constant CNR strategy required an increase in air kerma by

  7. An examination of automatic exposure control regimes for two digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Radiation Safety Section, Clinical Physics CAU, Dominion House, 60, Barts Close, St Bartholomew' s Hospital, EC1A 7BE, London (United Kingdom)], E-mail: nicholas.marshall@uz.kuleuven.ac.be

    2009-08-07

    The influence of two methods of an automatic exposure control (AEC) setup using a simple measure of detectability is examined as a function of x-ray beam quality for a computed radiography (CR) system and for an indirect conversion digital radiography (DR) system. The regimes assessed were constant air kerma at the detector and the constant contrast noise ratio (CNR). A low scatter geometry was employed with x-ray spectra varying from 60 kV and 1 mm Cu to 125 kV and 2 mm Cu. The CNR was measured using a 2 mm thick Al square of dimension 1 cm by 1 cm. Detectability was quantified via a nominal contrast for a fixed beam quality of 70 kV and 1 mm added Cu filtration, taken from c-d curves measured using the Leeds TO20 test object, for the four x-ray spectra. In addition, objective image quality parameters including modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) were also measured for both systems at the four different x-ray spectra. It was found that the constant air kerma strategy did not maintain threshold nominal contrast (simple detectability) constant as the x-ray beam mean energy increased, for either the CR system or the DR system. For the CR detector, the threshold nominal contrast for a 1 mm disc increased by a factor of 4.4 from 3.50% to 15.4% as the tube potential was raised from 60 kV to 125 kV, while for the DR detector, the threshold nominal contrast increased by a factor of 3.4, from 2.27% to 7.67% as the tube potential increased from 60 kV to 120 kV. The constant CNR method was more successful at maintaining constant detectability for the c-d discs. The threshold nominal contrast for the 1 mm disc changed by a factor of 1.2, from 4.80% to 5.70% for the CR system, as the spectrum changed from 60 kV to 125 kV. For the indirect conversion detector, the threshold nominal contrast increased from 2.27% to 5.66% (a factor of 1.4 increase). The constant CNR strategy required an increase in air kerma by

  8. Knowledge-based system for automatic MBR control.

    Science.gov (United States)

    Comas, J; Meabe, E; Sancho, L; Ferrero, G; Sipma, J; Monclús, H; Rodriguez-Roda, I

    2010-01-01

    MBR technology is currently challenging traditional wastewater treatment systems and is increasingly selected for WWTP upgrading. MBR systems typically are constructed on a smaller footprint, and provide superior treated water quality. However, the main drawback of MBR technology is that the permeability of membranes declines during filtration due to membrane fouling, which for a large part causes the high aeration requirements of an MBR to counteract this fouling phenomenon. Due to the complex and still unknown mechanisms of membrane fouling it is neither possible to describe clearly its development by means of a deterministic model, nor to control it with a purely mathematical law. Consequently the majority of MBR applications are controlled in an "open-loop" way i.e. with predefined and fixed air scour and filtration/relaxation or backwashing cycles, and scheduled inline or offline chemical cleaning as a preventive measure, without taking into account the real needs of membrane cleaning based on its filtration performance. However, existing theoretical and empirical knowledge about potential cause-effect relations between a number of factors (influent characteristics, biomass characteristics and operational conditions) and MBR operation can be used to build a knowledge-based decision support system (KB-DSS) for the automatic control of MBRs. This KB-DSS contains a knowledge-based control module, which, based on real time comparison of the current permeability trend with "reference trends", aims at optimizing the operation and energy costs and decreasing fouling rates. In practice the automatic control system proposed regulates the set points of the key operational variables controlled in MBR systems (permeate flux, relaxation and backwash times, backwash flows and times, aeration flow rates, chemical cleaning frequency, waste sludge flow rate and recycle flow rates) and identifies its optimal value. This paper describes the concepts and the 3-level architecture

  9. A SIMULATION ENVIRONMENT FOR AUTOMATIC NIGHT DRIVING AND VISUAL CONTROL

    OpenAIRE

    Arroyo Rubio, Fernando

    2012-01-01

    This project consists on developing an automatic night driving system in a simulation environment. The simulator I have used is TORCS. TORCS is an Open Source car racing simulator written in C++. It is used as an ordinary car racing game, as a IA racing game and as a research platform. The goal of this thesis is to implement an automatic driving system to control the car under night conditions using computer vision. A camera is implemented inside the vehicle and it will detect the reflective ...

  10. Analysis of the oscillation causes in automatic controller of reactor power

    International Nuclear Information System (INIS)

    Aleksakov, A.N.; Nikolaev, E.V.; Podlazov, L.N.

    1991-01-01

    Conditions for occurence of oscillations in automatic controller of reactor power are determined. Graphic-analytical method for calculating the stability of non-linear system, which enables one to reveal the most important factors determining the stability, is used. The practical results of the analysis are obtained for the system of local automatic comtrollers, used in the RBMK reactors. A simple method providing for the required stability margin, is suggested

  11. A joint network/control design for cooperative automatic driving

    NARCIS (Netherlands)

    Giordano, G.; Segata, Michele; Blanchini, Franco; Cigno, Renato Lo; Altintas, O.; Casetti, C.; Meireles, R.; Kirsch, N.; Lo Cigno, R.

    2017-01-01

    Cooperative automatic driving, or platooning, is a promising solution to improve traffic safety, while reducing congestion and pollution. The design of a control system for this application is a challenging, multi-disciplinary problem, as cooperation between vehicles is obtained through wireless

  12. Full-automatic Special Drill Hydraulic System and PLC Control

    Directory of Open Access Journals (Sweden)

    Tian Xue Jun

    2016-01-01

    Full Text Available A hydraulic-driven and PLC full-automatic special drill is introduced, working principle of the hydraulic system and PLC control system are analyzed and designed, this equipment has the advantages of high efficiency, superior quality and low cost etc.

  13. Simulation of the TREAT-Upgrade Automatic Reactor Control System

    International Nuclear Information System (INIS)

    Lipinski, W.C.; Kirsch, L.W.; Valente, A.D.

    1984-01-01

    This paper describes the design of the Automatic Reactor Control System (ARCS) for the Transient Reactor Test Facility (TREAT) Upgrade. A simulation was used to facilitate the ARCS design and to completely test and verify its operation before installation at the TREAT facility

  14. Application of the concept of dynamic trim control to automatic landing of carrier aircraft. [utilizing digital feedforeward control

    Science.gov (United States)

    Smith, G. A.; Meyer, G.

    1980-01-01

    The results of a simulation study of an alternative design concept for an automatic landing control system are presented. The alternative design concept for an automatic landing control system is described. The design concept is the total aircraft flight control system (TAFCOS). TAFCOS is an open loop, feed forward system that commands the proper instantaneous thrust, angle of attack, and roll angle to achieve the forces required to follow the desired trajector. These dynamic trim conditions are determined by an inversion of the aircraft nonlinear force characteristics. The concept was applied to an A-7E aircraft approaching an aircraft carrier. The implementation details with an airborne digital computer are discussed. The automatic carrier landing situation is described. The simulation results are presented for a carrier approach with atmospheric disturbances, an approach with no disturbances, and for tailwind and headwind gusts.

  15. 2011 International Conference in Electrics, Communication and Automatic Control Proceedings

    CERN Document Server

    2012-01-01

    This two-volume set contains the very latest, cutting-edge material in electrics, communication and automatic control. As a vital field of research that is highly relevant to current developments in a number of technological domains, the subjects it covers include micro-electronics and integrated circuit control, signal processing technology, next-generation network infrastructure, wireless communication and scientific instruments. The aim of the International Conference in Electrics, Communication and Automatic Control, held in Chongqing, China, in June 2011 was to provide a valuable inclusive platform for researchers, engineers, academicians and industrial professionals from all over the world to share their research results with fellow scientists in the sector. The call for papers netted well over 600 submissions, of which 224 were selected for presentation. This fully peer-reviewed collection of papers from the conference can be viewed as a single-source compendium of the latest trends and techniques in t...

  16. Man-system interface based on automatic speech recognition: integration to a virtual control desk

    Energy Technology Data Exchange (ETDEWEB)

    Jorge, Carlos Alexandre F.; Mol, Antonio Carlos A.; Pereira, Claudio M.N.A.; Aghina, Mauricio Alves C., E-mail: calexandre@ien.gov.b, E-mail: mol@ien.gov.b, E-mail: cmnap@ien.gov.b, E-mail: mag@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Nomiya, Diogo V., E-mail: diogonomiya@gmail.co [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)

    2009-07-01

    This work reports the implementation of a man-system interface based on automatic speech recognition, and its integration to a virtual nuclear power plant control desk. The later is aimed to reproduce a real control desk using virtual reality technology, for operator training and ergonomic evaluation purpose. An automatic speech recognition system was developed to serve as a new interface with users, substituting computer keyboard and mouse. They can operate this virtual control desk in front of a computer monitor or a projection screen through spoken commands. The automatic speech recognition interface developed is based on a well-known signal processing technique named cepstral analysis, and on artificial neural networks. The speech recognition interface is described, along with its integration with the virtual control desk, and results are presented. (author)

  17. Man-system interface based on automatic speech recognition: integration to a virtual control desk

    International Nuclear Information System (INIS)

    Jorge, Carlos Alexandre F.; Mol, Antonio Carlos A.; Pereira, Claudio M.N.A.; Aghina, Mauricio Alves C.; Nomiya, Diogo V.

    2009-01-01

    This work reports the implementation of a man-system interface based on automatic speech recognition, and its integration to a virtual nuclear power plant control desk. The later is aimed to reproduce a real control desk using virtual reality technology, for operator training and ergonomic evaluation purpose. An automatic speech recognition system was developed to serve as a new interface with users, substituting computer keyboard and mouse. They can operate this virtual control desk in front of a computer monitor or a projection screen through spoken commands. The automatic speech recognition interface developed is based on a well-known signal processing technique named cepstral analysis, and on artificial neural networks. The speech recognition interface is described, along with its integration with the virtual control desk, and results are presented. (author)

  18. CONCEPT OF AUTOMATIC CONTROL SYSTEM FOR IMPROVING THE EFFICIENCY OF THE ABSORPTION REFRIGERATING UNITS

    Directory of Open Access Journals (Sweden)

    O. Titlova

    2016-12-01

    Full Text Available The general concept of the automatic control systems constructing for increasing the efficiency of the artificial cold production process in the absorption refrigerating units is substantiated. The described automatic control systems provides necessary degree of the ammonia vapor purification from the water in all absorption refrigerating units modes and minimizes heat loss from the dephlegmator surface.

  19. 49 CFR 236.401 - Automatic block signal system and interlocking standards applicable to traffic control systems.

    Science.gov (United States)

    2010-10-01

    ... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Traffic Control Systems Standards § 236.401 Automatic... 49 Transportation 4 2010-10-01 2010-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations...

  20. Microsoft excel's automatic data processing and diagram drawing of RIA internal quality control parameters

    International Nuclear Information System (INIS)

    Zeng Pingfan; Liu Guoqiang

    2006-01-01

    We did automatic data processing and diagram drawing of various parameters of RIA' s internal quality control (IQC)by the use of Microsoft Excel (ME). By use of AVERAGE and STDEV of ME, we got x-bar, s and CV%. With pearson, we got the serum quality control coefficients (r). Inputing the original data to diagram's self-definition item, the diagram was drawn automatically. By the use of logic judging, we got the quality control judging results with the status, timing and data of various quality control parameters. For the past four years, the ME data processing and diagram drawing as well as quality control judging have been showed to be accurate, convenient and correct. It was quick and easy to manage and the automatic computer processing of RIA's IQC was realized. Conclusion: the method is applicable to all types of RIA' s IQC. (authors)

  1. An automatic tuning method of a fuzzy logic controller for nuclear reactors

    International Nuclear Information System (INIS)

    Ramaswamy, P.; Lee, K.Y.; Edwards, R.M.

    1993-01-01

    The design and evaluation by simulation of an automatically tuned fuzzy logic controller is presented. Typically, fuzzy logic controllers are designed based on an expert's knowledge of the process. However, this approach has its limitations in the fact that the controller is hard to optimize or tune to get the desired control action. A method to automate the tuning process using a simplified Kalman filter approach is presented for the fuzzy logic controller to track a suitable reference trajectory. Here, for purposes of illustration an optimal controller's response is used as a reference trajectory to determine automatically the rules for the fuzzy logic controller. To demonstrate the robustness of this design approach, a nonlinear six-delayed neutron group plant is controlled using a fuzzy logic controller that utilizes estimated reactor temperatures from a one-delayed neutron group observer. The fuzzy logic controller displayed good stability and performance robustness characteristics for a wide range of operation

  2. SELFADJUSTING AUTOMATIC CONTROL OF SOWING UNIT

    Directory of Open Access Journals (Sweden)

    A. Yu. Izmaylov

    2015-01-01

    Full Text Available The selfadjusting automatic control of sowing unit and differentiated introduction of mineral fertilizers doses according to agrochemical indicators of the soil (precision agriculture are used wider nowadays. It was defined that the main requirement to the differentiated seeding and fertilizing is an accuracy and duration of transition from one norm to another. Established that at a speed of unit of 10 km/h object moves for 0.5 s about on 1.5 m and more. Thus in this device the radio channel originated differentiated correction is updated in 10 s, and in the RTK mode - 0.5-2 s that breaks the accuracy of introduction of seeds and fertilizers. The block schematic diagram of system of automatic control of technological process of seeding and mineral fertilizing with use of navigation means of machine-tractor aggregates orientation in the field and technical means for realization of technology of precision agriculture at sowing and fertilizers application due to electronic maps of soil fertility and navigation satellite systems was worked out. It was noted that for regulation of a fertilizing dose it is necessary to complete the unit with the electric drive, and for error reduction use navigation GLONASS, GPS, Galileo receivers. To tracking of four leading navigation systems GPS/GLONASS/Galileo/Compass receiver with 32 canals developed by domestic-owned firm «KB NAVIS» was suggested. It was established that the automated device created by All-Russia Research Institute of Mechanization for Agriculture information based on NAVSTAR and GLONASS/GPS system successfully operates seeding and make possible the differentiate fertilizing.

  3. Automatic and controlled components of judgment and decision making.

    Science.gov (United States)

    Ferreira, Mario B; Garcia-Marques, Leonel; Sherman, Steven J; Sherman, Jeffrey W

    2006-11-01

    The categorization of inductive reasoning into largely automatic processes (heuristic reasoning) and controlled analytical processes (rule-based reasoning) put forward by dual-process approaches of judgment under uncertainty (e.g., K. E. Stanovich & R. F. West, 2000) has been primarily a matter of assumption with a scarcity of direct empirical findings supporting it. The present authors use the process dissociation procedure (L. L. Jacoby, 1991) to provide convergent evidence validating a dual-process perspective to judgment under uncertainty based on the independent contributions of heuristic and rule-based reasoning. Process dissociations based on experimental manipulation of variables were derived from the most relevant theoretical properties typically used to contrast the two forms of reasoning. These include processing goals (Experiment 1), cognitive resources (Experiment 2), priming (Experiment 3), and formal training (Experiment 4); the results consistently support the author's perspective. They conclude that judgment under uncertainty is neither an automatic nor a controlled process but that it reflects both processes, with each making independent contributions.

  4. Automatic and deliberate affective associations with sexual stimuli in women with lifelong vaginismus before and after therapist-aided exposure treatment

    NARCIS (Netherlands)

    Melles, Reinhilde J.; ter Kuile, Moniek M.; Dewitte, Marieke; van Lankveld, Jacques J. D. M.; Brauer, Marieke; de Jong, Peter J.

    2014-01-01

    The intense fear response to vaginal penetration in women with lifelong vaginismus, who have never been able to experience coitus, may reflect negative automatic and deliberate appraisals of vaginal penetration stimuli which might be modified by exposure treatment. The aim of this study is to

  5. Implementation of an Automatic Stop Order and Initial Antibiotic Exposure in Very Low Birth Weight Infants.

    Science.gov (United States)

    Tolia, Veeral N; Desai, Sujata; Qin, Huanying; Rayburn, Polli D; Poon, Grace; Murthy, Karna; Ellsbury, Dan L; Chiruvolu, Arpitha

    2017-01-01

    Objective  To evaluate if an antibiotic automatic stop order (ASO) changed early antibiotic exposure (use in the first 7 days of life) or clinical outcomes in very low birth weight (VLBW) infants. Study Design  We compared birth characteristics, early antibiotic exposure, morbidity, and mortality data in VLBW infants (with birth weight  48 hours. Secondary outcomes included mortality, early mortality, early onset sepsis (EOS), and necrotizing enterocolitis. Results  Birth characteristics were similar between the two groups. We observed reduced median antibiotic exposure (pre-ASO: 6.5 DOT vs. Post-ASO: 4 DOT; p   48 hours (63.4 vs. 41.3%; p  < 0.001). There were no differences in mortality (12.1 vs 10.2%; p  = 0.44), early mortality, or other reported morbidities. EOS accounted for less than 10% of early antibiotic use. Conclusion  Early antibiotic exposure was reduced after the implementation of an ASO without changes in observed outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  7. Evaluation of impedance on biological Tissues using automatic control measurement system

    International Nuclear Information System (INIS)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo; Lee, Moo Seok; Kim, Sang Sik; Kim, Gun FDo; Lee, Jong Kyu

    2015-01-01

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  8. Study on application of adaptive fuzzy control and neural network in the automatic leveling system

    Science.gov (United States)

    Xu, Xiping; Zhao, Zizhao; Lan, Weiyong; Sha, Lei; Qian, Cheng

    2015-04-01

    This paper discusses the adaptive fuzzy control and neural network BP algorithm in large flat automatic leveling control system application. The purpose is to develop a measurement system with a flat quick leveling, Make the installation on the leveling system of measurement with tablet, to be able to achieve a level in precision measurement work quickly, improve the efficiency of the precision measurement. This paper focuses on the automatic leveling system analysis based on fuzzy controller, Use of the method of combining fuzzy controller and BP neural network, using BP algorithm improve the experience rules .Construct an adaptive fuzzy control system. Meanwhile the learning rate of the BP algorithm has also been run-rate adjusted to accelerate convergence. The simulation results show that the proposed control method can effectively improve the leveling precision of automatic leveling system and shorten the time of leveling.

  9. [Modeling and implementation method for the automatic biochemistry analyzer control system].

    Science.gov (United States)

    Wang, Dong; Ge, Wan-cheng; Song, Chun-lin; Wang, Yun-guang

    2009-03-01

    In this paper the system structure The automatic biochemistry analyzer is a necessary instrument for clinical diagnostics. First of is analyzed. The system problems description and the fundamental principles for dispatch are brought forward. Then this text puts emphasis on the modeling for the automatic biochemistry analyzer control system. The objects model and the communications model are put forward. Finally, the implementation method is designed. It indicates that the system based on the model has good performance.

  10. Data-driven automatic parking constrained control for four-wheeled mobile vehicles

    OpenAIRE

    Wenxu Yan; Jing Deng; Dezhi Xu

    2016-01-01

    In this article, a novel data-driven constrained control scheme is proposed for automatic parking systems. The design of the proposed scheme only depends on the steering angle and the orientation angle of the car, and it does not involve any model information of the car. Therefore, the proposed scheme-based automatic parking system is applicable to different kinds of cars. In order to further reduce the desired trajectory coordinate tracking errors, a coordinates compensation algorithm is als...

  11. Intelligent buildings, automatic fire alarm and fire-protection control system

    International Nuclear Information System (INIS)

    Tian Deyuan

    1999-01-01

    The author describes in brief the intelligent buildings, and the automatic fire alarm and fire-protection control system. On the basis of the four-bus, three-bus and two-bus, a new transfer technique was developed

  12. Control System Design for Automatic Cavity Tuning Machines

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Khabiboulline, T.; Kotelnikov, S.; Makulski, A.; Nehring, R.; Nogiec, J.; Ross, M.; Schappert, W.; /Fermilab; Goessel, A.; Iversen, J.; Klinke, D.; /DESY

    2009-05-01

    A series of four automatic tuning machines for 9-cell TESLA-type cavities are being developed and fabricated in a collaborative effort among DESY, FNAL, and KEK. These machines are intended to support high-throughput cavity fabrication for construction of large SRF-based accelerator projects. Two of these machines will be delivered to cavity vendors for the tuning of XFEL cavities. The control system for these machines must support a high level of automation adequate for industrial use by non-experts operators. This paper describes the control system hardware and software design for these machines.

  13. Control System Design for Automatic Cavity Tuning Machines

    International Nuclear Information System (INIS)

    Carcagno, R.; Khabiboulline, T.; Kotelnikov, S.; Makulski, A.; Nehring, R.; Nogiec, J.; Ross, M.; Schappert, W.; Goessel, A.; Iversen, J.; Klinke, D.

    2009-01-01

    A series of four automatic tuning machines for 9-cell TESLA-type cavities are being developed and fabricated in a collaborative effort among DESY, FNAL, and KEK. These machines are intended to support high-throughput cavity fabrication for construction of large SRF-based accelerator projects. Two of these machines will be delivered to cavity vendors for the tuning of XFEL cavities. The control system for these machines must support a high level of automation adequate for industrial use by non-experts operators. This paper describes the control system hardware and software design for these machines.

  14. Automatic control system generation for robot design validation

    Science.gov (United States)

    Bacon, James A. (Inventor); English, James D. (Inventor)

    2012-01-01

    The specification and drawings present a new method, system and software product for and apparatus for generating a robotic validation system for a robot design. The robotic validation system for the robot design of a robotic system is automatically generated by converting a robot design into a generic robotic description using a predetermined format, then generating a control system from the generic robotic description and finally updating robot design parameters of the robotic system with an analysis tool using both the generic robot description and the control system.

  15. Statistical analysis of quality control of automatic processor

    International Nuclear Information System (INIS)

    Niu Yantao; Zhao Lei; Zhang Wei; Yan Shulin

    2002-01-01

    Objective: To strengthen the scientific management of automatic processor and promote QC, based on analyzing QC management chart for automatic processor by statistical method, evaluating and interpreting the data and trend of the chart. Method: Speed, contrast, minimum density of step wedge of film strip were measured everyday and recorded on the QC chart. Mean (x-bar), standard deviation (s) and range (R) were calculated. The data and the working trend were evaluated and interpreted for management decisions. Results: Using relative frequency distribution curve constructed by measured data, the authors can judge whether it is a symmetric bell-shaped curve or not. If not, it indicates a few extremes overstepping control limits possibly are pulling the curve to the left or right. If it is a normal distribution, standard deviation (s) is observed. When x-bar +- 2s lies in upper and lower control limits of relative performance indexes, it indicates the processor works in stable status in this period. Conclusion: Guided by statistical method, QC work becomes more scientific and quantified. The authors can deepen understanding and application of the trend chart, and improve the quality management to a new step

  16. MAS Based Distributed Automatic Generation Control for Cyber-Physical Microgrid System

    Institute of Scientific and Technical Information of China (English)

    Zhongwen Li; Chuanzhi Zang; Peng Zeng; Haibin Yu; Hepeng Li

    2016-01-01

    The microgrid is a typical cyber-physical microgrid system(CPMS). The physical unconventional distributed generators(DGs) are intermittent and inverter-interfaced which makes them very different to control. The cyber components,such as the embedded computer and communication network,are equipped with DGs, to process and transmit the necessary information for the controllers. In order to ensure system-wide observability, controllability and stabilization for the microgrid,the cyber and physical component need to be integrated. For the physical component of CPMS, the droop-control method is popular as it can be applied in both modes of operation to improve the grid transient performance. Traditional droop control methods have the drawback of the inherent trade-off between power sharing and voltage and frequency regulation. In this paper, the global information(such as the average voltage and the output active power of the microgrid and so on) are acquired distributedly based on multi-agent system(MAS). Based on the global information from cyber components of CPMS, automatic generation control(AGC) and automatic voltage control(AVC)are proposed to deal with the drawback of traditional droop control. Simulation studies in PSCAD demonstrate the effectiveness of the proposed control methods.

  17. MAS Based Distributed Automatic Generation Control for Cyber-Physical Microgrid System

    Institute of Scientific and Technical Information of China (English)

    Zhongwen Li; Chuanzhi Zang; Peng Zeng; Haibin Yu; Hepeng Li

    2016-01-01

    The microgrid is a typical cyber-physical micro grid system (CPMS).The physical unconventional distributed generators (DGs) are intermittent and inverter-interfaced which makes them very different to control.The cyber components,such as the embedded computer and communication network,are equipped with DGs,to process and transmit the necessary information for the controllers.In order to ensure system-wide observability,controllability and stabilization for the microgrid,the cyber and physical component need to be integrated.For the physical component of CPMS,the droop-control method is popular as it can be applied in both modes of operation to improve the grid transient performance.Traditional droop control methods have the drawback of the inherent trade-off between power sharing and voltage and frequency regulation.In this paper,the global information (such as the average voltage and the output active power of the microgrid and so on) are acquired distributedly based on multi-agent system (MAS).Based on the global information from cyber components of CPMS,automatic generation control (AGC) and automatic voltage control (AVC) are proposed to deal with the drawback of traditional droop control.Simulation studies in PSCAD demonstrate the effectiveness of the proposed control methods.

  18. Design of Simulink module for dynamic reactivity simulation of marine reactor automatic control rod

    International Nuclear Information System (INIS)

    Chen Zhiyun; Luo Lei; Chen Wenzhen; Gui Xuewen

    2010-01-01

    The power of marine reactor varies frequently and acutely, which induces the frequent and acute adjustment of the automatic control rod. According to the characteristics of marine reactor and the problem of improper control rod reactivity insertion in previous literatures, the Simulink module for dynamic reactivity simulation of automatic control rod was designed and adopted as a sub-module of Simulink program for the fast calculation of the physical and thermal parameters of marine reactor. A typical dynamic process of the marine reactor was used as the benchmark, which indicates that the designed Simulink module is capable of the dynamic simulation of automatic control rod position and reactivity, and is adequate to the fast calculation of physic and thermal parameters. The Simulink module is of significant meaning to the simulation of the dynamic process of marine reactor and the fast calculation of the operating parameters. (authors)

  19. A modern automatic Carriage-Trolley Position Control System for Dhruva fuelling machine

    International Nuclear Information System (INIS)

    Agrawal, Ankit; Hari Balakrishna; Narvekar, J.P.; Sanadhya, Vivek

    2014-01-01

    A fully automatic absolute encoder based position control system has been designed developed implemented and commissioned for the Dhruva Fuelling Machine A (FM/A). This supports both the coarse and fine positioning modes. Provision for fully manual positioning as a standby system has been retained. This system replaces the ageing peg counting based incremental positioner used briefly during the early period after the Dhruva FM/A was commissioned. The older system suffered from peg detection skipping problems; hence it was not being used. Only full manual positioning was being carried out. This paper describes the automatic Carriage Trolley Position Control System (CTPCS). (author)

  20. Automatic frequency control system for driving a linear accelerator

    International Nuclear Information System (INIS)

    Helgesson, A.L.

    1976-01-01

    An automatic frequency control system is described for maintaining the drive frequency applied to a linear accelerator to produce maximum particle output from the accelerator. The particle output amplitude is measured and the frequency of the radio frequency source powering the linear accelerator is adjusted to maximize particle output amplitude

  1. An automatic control unit for A neutron diffraction crystal spectrometer

    International Nuclear Information System (INIS)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer

  2. A Plant Control Technology Using Reinforcement Learning Method with Automatic Reward Adjustment

    Science.gov (United States)

    Eguchi, Toru; Sekiai, Takaaki; Yamada, Akihiro; Shimizu, Satoru; Fukai, Masayuki

    A control technology using Reinforcement Learning (RL) and Radial Basis Function (RBF) Network has been developed to reduce environmental load substances exhausted from power and industrial plants. This technology consists of the statistic model using RBF Network, which estimates characteristics of plants with respect to environmental load substances, and RL agent, which learns the control logic for the plants using the statistic model. In this technology, it is necessary to design an appropriate reward function given to the agent immediately according to operation conditions and control goals to control plants flexibly. Therefore, we propose an automatic reward adjusting method of RL for plant control. This method adjusts the reward function automatically using information of the statistic model obtained in its learning process. In the simulations, it is confirmed that the proposed method can adjust the reward function adaptively for several test functions, and executes robust control toward the thermal power plant considering the change of operation conditions and control goals.

  3. Experimental Breeder Reactor-II automatic control-rod-drive system

    International Nuclear Information System (INIS)

    Christensen, L.J.

    1983-01-01

    A computer-controlled automatic control rod drive system (ACRDS) was designed and operated in EBR-II during reactor runs 121 and 122. The ACRDS was operated in a checkout mode during run 121 using a low worth control rod. During run 122 a high worth control rod was used to perform overpower transient tests as part of the LMFBR oxide fuels transient testing program. The testing program required an increase in power of 4 MW/s, a hold time of 12 minutes and a power decrease of 4 MW/s. During run 122, 13 power transients were performed

  4. Automatic guidance and control laws for helicopter obstacle avoidance

    Science.gov (United States)

    Cheng, Victor H. L.; Lam, T.

    1992-01-01

    The authors describe the implementation of a full-function guidance and control system for automatic obstacle avoidance in helicopter nap-of-the-earth (NOE) flight. The guidance function assumes that the helicopter is sufficiently responsive so that the flight path can be readily adjusted at NOE speeds. The controller, basically an autopilot for following the derived flight path, was implemented with parameter values to control a generic helicopter model used in the simulation. Evaluation of the guidance and control system with a 3-dimensional graphical helicopter simulation suggests that the guidance has the potential for providing good and meaningful flight trajectories.

  5. Automatic learning rate adjustment for self-supervising autonomous robot control

    Science.gov (United States)

    Arras, Michael K.; Protzel, Peter W.; Palumbo, Daniel L.

    1992-01-01

    Described is an application in which an Artificial Neural Network (ANN) controls the positioning of a robot arm with five degrees of freedom by using visual feedback provided by two cameras. This application and the specific ANN model, local liner maps, are based on the work of Ritter, Martinetz, and Schulten. We extended their approach by generating a filtered, average positioning error from the continuous camera feedback and by coupling the learning rate to this error. When the network learns to position the arm, the positioning error decreases and so does the learning rate until the system stabilizes at a minimum error and learning rate. This abolishes the need for a predetermined cooling schedule. The automatic cooling procedure results in a closed loop control with no distinction between a learning phase and a production phase. If the positioning error suddenly starts to increase due to an internal failure such as a broken joint, or an environmental change such as a camera moving, the learning rate increases accordingly. Thus, learning is automatically activated and the network adapts to the new condition after which the error decreases again and learning is 'shut off'. The automatic cooling is therefore a prerequisite for the autonomy and the fault tolerance of the system.

  6. Automatically-Activated Attitudes as Mechanisms for Message Effects: The Case of Alcohol Advertisements.

    Science.gov (United States)

    Goodall, Catherine E; Slater, Michael D

    2010-10-01

    Alcohol advertisements may influence impulsive, risky behaviors indirectly, via automatically-activated attitudes toward alcohol. Results from an experiment in which participants were exposed to either four alcohol advertisements, four control advertisements, or four drunk driving public service advertisements, suggested that alcohol advertisements had more measurable effects on implicit, than on explicit attitude measures. Moreover, there were significant indirect paths from alcohol advertisement exposure through automatically-activated alcohol attitudes on willingness to engage in risky alcohol-related behaviors, notably drinking and driving. A mechanism that may explain how these advertisements activate automatic, non-deliberative alcohol attitudes was investigated. Associative evidence was found supportive of an evaluative conditioning mechanism, in which positive responses to an alcohol advertisement may lead to more positive automatically-activated attitudes toward alcohol itself.

  7. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  8. Initial ideas for automatic design and verification of control logic in reversible HDLs

    DEFF Research Database (Denmark)

    Wille, Robert; Keszocze, Oliver; Othmer, Lars

    2016-01-01

    not obvious. Moreover, implementations exist which may not be realized with a reversible control flow at all. In this work, we propose automatic methods for descriptions in the reversible HDL SyReC that can generate the required fi-conditions and check whether a reversible control flow indeed can be realized....... The envisioned solution utilizes predicate transformer semantics based on Hoare logic. The presented ideas constitute the first steps towards automatic methods for these important designs steps in the domain of reversible circuit design....

  9. Intelligent control schemes applied to Automatic Generation Control

    Directory of Open Access Journals (Sweden)

    Dingguo Chen

    2016-04-01

    Full Text Available Integrating ever increasing amount of renewable generating resources to interconnected power systems has created new challenges to the safety and reliability of today‟s power grids and posed new questions to be answered in the power system modeling, analysis and control. Automatic Generation Control (AGC must be extended to be able to accommodate the control of renewable generating assets. In addition, AGC is mandated to operate in accordance with the NERC‟s Control Performance Standard (CPS criteria, which represent a greater flexibility in relaxing the control of generating resources and yet assuring the stability and reliability of interconnected power systems when each balancing authority operates in full compliance. Enhancements in several aspects to the traditional AGC must be made in order to meet the aforementioned challenges. It is the intention of this paper to provide a systematic, mathematical formulation for AGC as a first attempt in the context of meeting the NERC CPS requirements and integrating renewable generating assets, which has not been seen reported in the literature to the best knowledge of the authors. Furthermore, this paper proposes neural network based predictive control schemes for AGC. The proposed controller is capable of handling complicated nonlinear dynamics in comparison with the conventional Proportional Integral (PI controller which is typically most effective to handle linear dynamics. The neural controller is designed in such a way that it has the capability of controlling the system generation in the relaxed manner so the ACE is controlled to a desired range instead of driving it to zero which would otherwise increase the control effort and cost; and most importantly the resulting system control performance meets the NERC CPS requirements and/or the NERC Balancing Authority’s ACE Limit (BAAL compliance requirements whichever are applicable.

  10. Using Face Recognition in the Automatic Door Access Control in a Secured Room

    Directory of Open Access Journals (Sweden)

    Gheorghe Gilca

    2017-06-01

    Full Text Available The aim of this paper is to help users improve the door security of sensitive locations by using face detection and recognition. This paper is comprised mainly of three subsystems: face detection, face recognition and automatic door access control. The door will open automatically for the known person due to the command of the microcontroller.

  11. Cognitive tasks promote automatization of postural control in young and older adults.

    Science.gov (United States)

    Potvin-Desrochers, Alexandra; Richer, Natalie; Lajoie, Yves

    2017-09-01

    Researchers looking at the effects of performing a concurrent cognitive task on postural control in young and older adults using traditional center-of-pressure measures and complexity measures found discordant results. Results of experiments showing improvements of stability have suggested the use of strategies such as automatization of postural control or stiffening strategy. This experiment aimed to confirm in healthy young and older adults that performing a cognitive task while standing leads to improvements that are due to automaticity of sway by using sample entropy. Twenty-one young adults and twenty-five older adults were asked to stand on a force platform while performing a cognitive task. There were four cognitive tasks: simple reaction time, go/no-go reaction time, equation and occurrence of a digit in a number sequence. Results demonstrated decreased sway area and variability as well as increased sample entropy for both groups when performing a cognitive task. Results suggest that performing a concurrent cognitive task promotes the adoption of an automatic postural control in young and older adults as evidenced by an increased postural stability and postural sway complexity. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development and application of automatic frequency and power control systems for large power units

    Energy Technology Data Exchange (ETDEWEB)

    V.A. Bilenko; A.D. Melamed; E.E. Mikushevich; D.Y. Nikol' skii; R.L. Rogachev; N.A. Romanov [ZAO Interavtomatika (Interautomatika AG), Moscow (Russian Federation)

    2008-07-01

    We describe the results of work carried out at ZAO Interavtomatika on the development and putting into use of a system for automatically controlling the frequency and power output of large coal-fired power units involving the retrofitting of the turbine's hydraulic automatic control system. Certificates affirming conformity to the Standard of the System Operator Centralized Dispatching Administration (SO-CDA) have been received for eight power units as an outcome of these efforts.

  13. Consistently Trained Artificial Neural Network for Automatic Ship Berthing Control

    Directory of Open Access Journals (Sweden)

    Y.A. Ahmed

    2015-09-01

    Full Text Available In this paper, consistently trained Artificial Neural Network controller for automatic ship berthing is discussed. Minimum time course changing manoeuvre is utilised to ensure such consistency and a new concept named ‘virtual window’ is introduced. Such consistent teaching data are then used to train two separate multi-layered feed forward neural networks for command rudder and propeller revolution output. After proper training, several known and unknown conditions are tested to judge the effectiveness of the proposed controller using Monte Carlo simulations. After getting acceptable percentages of success, the trained networks are implemented for the free running experiment system to judge the network’s real time response for Esso Osaka 3-m model ship. The network’s behaviour during such experiments is also investigated for possible effect of initial conditions as well as wind disturbances. Moreover, since the final goal point of the proposed controller is set at some distance from the actual pier to ensure safety, therefore a study on automatic tug assistance is also discussed for the final alignment of the ship with actual pier.

  14. Automatic control in multidrive electrotechnical complexes with semiconductor converters

    Science.gov (United States)

    Vasilev, B. U.; Mardashov, D. V.

    2017-01-01

    The frequency convertor and the automatic control system, which can be used in the multi-drive electromechanical system with a few induction motions, are considered. The paper presents the structure of existing modern multi-drive electric drives inverters, namely, electric drives with a total frequency converter and few electric motions, and an electric drive, in which the converter is used for power supply and control of the independent frequency. It was shown that such technical solutions of frequency converters possess a number of drawbacks. The drawbacks are given. It was shown that the control of technological processes using the electric drive of this structure may be provided under very limited conditions, as the energy efficiency and the level of electromagnetic compatibility of electric drives is low. The authors proposed using a multi-inverter structure with an active rectifier in multidrive electric drives with induction motors frequency converters. The application of such frequency converter may solve the problem of electromagnetic compatibility, namely, consumption of sinusoidal currents from the network and the maintenance of a sinusoidal voltage and energy compatibility, namely, consumption of practically active energy from the network. Also, the paper proposes the use of the automatic control system, which by means of a multi-inverter frequency converter provides separate control of drive machines and flexible regulation of technological processes. The authors present oscillograms, which confirm the described characteristics of the developed electrical drive. The possible subsequent ways to improve the multi-motor drives are also described.

  15. A unique concept for automatically controlling the braking action of wheeled vehicles during minimum distance stops

    Science.gov (United States)

    Barthlome, D. E.

    1975-01-01

    Test results of a unique automatic brake control system are outlined and a comparison is made of its mode of operation to that of an existing skid control system. The purpose of the test system is to provide automatic control of braking action such that hydraulic brake pressure is maintained at a near constant, optimum value during minimum distance stops.

  16. Incorrectly placed gonad shields: Effect on CT automatic exposure correction from four different scanners

    International Nuclear Information System (INIS)

    Martin Weber Kusk, R.T.

    2014-01-01

    Purpose: To examine the influence of incorrectly placed gonad shields on radiation dose when performing abdominal CT with automatic exposure correction, using systems from different vendors. Methods and materials: An anthropomorphic phantom was scanned without gonad shields, and with gonad shields placed in two different positions relative to the scan range. Dose Length Product was recorded. mA distribution in the longitudinal direction was plotted. Mean dose was compared using the t-test. Results: Three scanners showed different increase in relative DLP according to shield position. Conclusion: Care must be taken when placing lead shielding at CT and characteristics of each scanner should be known to the operator

  17. A versatile Czochralski crystal growth system with automatic diameter control

    Science.gov (United States)

    Aggarwal, M. D.; Metzl, R.; Wang, W. S.; Choi, J.

    1995-07-01

    A versatile Czochralski crystal pulling system with automatic diameter control for the growth of nonlinear optical oxide crystals is discussed. Pure and doped bulk single crystals of bismuth silicon oxide (Bi12SiO20) have been successfully grown using this system. The system consists of a regular Czochralski type pulling system with provision for continuous weighing of the growing crystal to provide feedback for power control.

  18. Adaptive neuro-fuzzy inference system based automatic generation control

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, S.H.; Etemadi, A.H. [Department of Electrical Engineering, Sharif University of Technology, Tehran (Iran)

    2008-07-15

    Fixed gain controllers for automatic generation control are designed at nominal operating conditions and fail to provide best control performance over a wide range of operating conditions. So, to keep system performance near its optimum, it is desirable to track the operating conditions and use updated parameters to compute control gains. A control scheme based on artificial neuro-fuzzy inference system (ANFIS), which is trained by the results of off-line studies obtained using particle swarm optimization, is proposed in this paper to optimize and update control gains in real-time according to load variations. Also, frequency relaxation is implemented using ANFIS. The efficiency of the proposed method is demonstrated via simulations. Compliance of the proposed method with NERC control performance standard is verified. (author)

  19. Repeated cocaine exposure facilitates the expression of incentive motivation and induces habitual control in rats.

    Directory of Open Access Journals (Sweden)

    Kimberly H LeBlanc

    Full Text Available There is growing evidence that mere exposure to drugs can induce long-term alterations in the neural systems that mediate reward processing, motivation, and behavioral control, potentially causing the pathological pursuit of drugs that characterizes the addicted state. The incentive sensitization theory proposes that drug exposure potentiates the influence of reward-paired cues on behavior. It has also been suggested that drug exposure biases action selection towards the automatic execution of habits and away from more deliberate goal-directed control. The current study investigated whether rats given repeated exposure to peripherally administered cocaine would show alterations in incentive motivation (assayed using the Pavlovian-to-instrumental transfer (PIT paradigm or habit formation (assayed using sensitivity to reward devaluation. After instrumental and Pavlovian training for food pellet rewards, rats were given 6 daily injections of cocaine (15 mg/kg, IP or saline, followed by a 10-d period of rest. Consistent with the incentive sensitization theory, cocaine-treated rats showed stronger cue-evoked lever pressing than saline-treated rats during the PIT test. The same rats were then trained on a new instrumental action with a new food pellet reward before undergoing a reward devaluation testing. Although saline-treated rats exhibited sensitivity to reward devaluation, indicative of goal-directed performance, cocaine-treated rats were insensitive to this treatment, suggesting a reliance on habitual processes. These findings, when taken together, indicate that repeated exposure to cocaine can cause broad alterations in behavioral control, spanning both motivational and action selection processes, and could therefore help explain aberrations of decision-making that underlie drug addiction.

  20. Repeated cocaine exposure facilitates the expression of incentive motivation and induces habitual control in rats.

    Science.gov (United States)

    LeBlanc, Kimberly H; Maidment, Nigel T; Ostlund, Sean B

    2013-01-01

    There is growing evidence that mere exposure to drugs can induce long-term alterations in the neural systems that mediate reward processing, motivation, and behavioral control, potentially causing the pathological pursuit of drugs that characterizes the addicted state. The incentive sensitization theory proposes that drug exposure potentiates the influence of reward-paired cues on behavior. It has also been suggested that drug exposure biases action selection towards the automatic execution of habits and away from more deliberate goal-directed control. The current study investigated whether rats given repeated exposure to peripherally administered cocaine would show alterations in incentive motivation (assayed using the Pavlovian-to-instrumental transfer (PIT) paradigm) or habit formation (assayed using sensitivity to reward devaluation). After instrumental and Pavlovian training for food pellet rewards, rats were given 6 daily injections of cocaine (15 mg/kg, IP) or saline, followed by a 10-d period of rest. Consistent with the incentive sensitization theory, cocaine-treated rats showed stronger cue-evoked lever pressing than saline-treated rats during the PIT test. The same rats were then trained on a new instrumental action with a new food pellet reward before undergoing a reward devaluation testing. Although saline-treated rats exhibited sensitivity to reward devaluation, indicative of goal-directed performance, cocaine-treated rats were insensitive to this treatment, suggesting a reliance on habitual processes. These findings, when taken together, indicate that repeated exposure to cocaine can cause broad alterations in behavioral control, spanning both motivational and action selection processes, and could therefore help explain aberrations of decision-making that underlie drug addiction.

  1. Automatic temperature control method of shipping can

    International Nuclear Information System (INIS)

    Nishikawa, Kaoru.

    1992-01-01

    The present invention provides a method of rapidly and accurately controlling the temperature of a shipping can, which is used upon shipping inspection for a nuclear fuel assembly. That is, a measured temperature value of the shipping can is converted to a gas pressure setting value in a jacket of the shipping can by conducting a predetermined logic calculation by using a fuzzy logic. A gas pressure control section compares the pressure setting value of a fuzzy estimation section and the measured value of the gas pressure in the jacket of the shipping can, and conducts air supply or exhaustion of the jacket gas so as to adjust the measured value with the setting value. These fuzzy estimation section and gas pressure control section control the gas pressure in the jacket of the shipping can to control the water level in the jacket. As a result, the temperature of the shipping can is controlled. With such procedures, since the water level in the jacket can be controlled directly and finely, temperature of the shipping can is automatically controlled rapidly and accurately compared with a conventional case. (I.S.)

  2. Sensitometric Control of Automatic Processors in a Hospital Center : Retrospective Study

    International Nuclear Information System (INIS)

    Lobato Busto, R.; Pombar Camean, M.

    1992-01-01

    This paper analyses the results obtained between February (1990) and July (1991) of the sensitometric control of the seven automatic processors which are in Hospital General de Galicia-Clinico Universitario (Santiago de Compostela). The deviations with regard to the reference values of each processor, permitting the precocious detection of disturbances before being revealed by the image, were analysed. In this analysis, it was achieved that the days in which the automatic processors were out of standing only varied between 2.3% and 5% from the checked days. (author)

  3. Stop valve with automatic control and locking for nuclear reactors

    International Nuclear Information System (INIS)

    Chung, D.K.

    1980-01-01

    This invention generally concerns an automatic control and locking stop valve. Specifically it relates to the use of such a valve in a nuclear reactor of the type containing absorber elements supported by a fluid and intended for stopping the reactor in complete safety [fr

  4. Specific predictive power of automatic spider-related affective associations for controllable and uncontrollable fear responses toward spiders

    NARCIS (Netherlands)

    Huijdlng, J; de Jong, PJ; Huijding, J.

    This study examined the predictive power of automatically activated spider-related affective associations for automatic and controllable fear responses. The Extrinsic Affective Simon Task (EAST; De Houwer, 2003) was used to indirectly assess automatic spider fear-related associations. The EAST and

  5. Programmable Logic Controllers for Systems of Automatic of the Level Crossing

    Directory of Open Access Journals (Sweden)

    Mieczyslaw Kornaszewski

    2006-01-01

    Full Text Available The railway crossings are vulnerable to incidence of high number of accidents often deadly. In order to face this problem, the modern systems of automatic of the level crossing have been introduced. These systems are based on Programmable Logic Controllers, which allow the designers to exploit self-control mechanisms, events acquiring, technical diagnostic which in turn enable remote control and acquisition of faults.

  6. Evaluation of the individual tube current setting in electrocardiogram-gated cardiac computed tomography estimated from plain chest computed tomography using computed tomography automatic exposure control

    International Nuclear Information System (INIS)

    Kishimoto, Junichi; Sakou, Toshio; Ohta, Yasutoshi

    2013-01-01

    The aim of this study was to estimate the tube current on a cardiac computed tomography (CT) from a plain chest CT using CT-automatic exposure control (CT-AEC), to obtain consistent image noise, and to optimize the scan tube current by individualizing the tube current. Sixty-five patients (Group A) underwent cardiac CT at fixed tube current. The mAs value for plain chest CT using CT-AEC (AEC value) and cardiac CT image noise were measured. The tube current needed to obtain the intended level of image noise in the cardiac CT was determined from their correlation. Another 65 patients (Group B) underwent cardiac CT with tube currents individually determined from the AEC value. Image noise was compared among Group A and B. Image noise of cardiac CT in Group B was 24.4±3.1 Hounsfield unit (HU) and was more uniform than in Group A (21.2±6.1 HU). The error with the desired image noise of 25 HU was lower in Group B (2.4%) than in Group A (15.2%). Individualized tube current selection based on AEC value thus provided consistent image noise and a scan tube current optimized for cardiac CT. (author)

  7. A device for automatic photoelectric control of the analytical gap for emission spectrographs

    Science.gov (United States)

    Dietrich, John A.; Cooley, Elmo F.; Curry, Kenneth J.

    1977-01-01

    A photoelectric device has been built that automatically controls the analytical gap between electrodes during excitation period. The control device allows for precise control of the analytical gap during the arcing process of samples, resulting in better precision of analysis.

  8. An automatic frequency control system of 2-MeV electronic LINAC

    International Nuclear Information System (INIS)

    Hu Xue; Zhang Junqiang; Zhong Shaopeng; Zhao Minghua

    2013-01-01

    Background: In electronic LINAC, the magnetron is often used as power source. The output frequency of magnetron always changes with the environment and the frequency difference between the output of magnetron and the frequency of accelerator, which will result in the bad performance of LINAC systems. Purpose: To ensure the performance of the work of entire LINAC system effectively, an automatic frequency control system is necessary. Methods: A phase locked frequency discriminator is designed to discriminate the frequency of accelerator guide and magnetron, and analogue circuit is used to process the output signals of frequency discriminator unit. Results: Working with the automatic frequency control (AFC) system, the output frequency of magnetron can be controlled in the range of (2998 MHz, 2998 MHz + 70 kHz) and (2998 MHz, 2998 MHz - 30 kHz). Conclusions: Under the measurement and debug, the functionality of frequency discriminator unit and signal processor circuit is tested effectively. (authors)

  9. Automatic Quadcopter Control Avoiding Obstacle Using Camera with Integrated Ultrasonic Sensor

    Science.gov (United States)

    Anis, Hanafi; Haris Indra Fadhillah, Ahmad; Darma, Surya; Soekirno, Santoso

    2018-04-01

    Automatic navigation on the drone is being developed these days, a wide variety of types of drones and its automatic functions. Drones used in this study was an aircraft with four propellers or quadcopter. In this experiment, image processing used to recognize the position of an object and ultrasonic sensor used to detect obstacle distance. The method used to trace an obsctacle in image processing was the Lucas-Kanade-Tomasi Tracker, which had been widely used due to its high accuracy. Ultrasonic sensor used to complement the image processing success rate to be fully detected object. The obstacle avoidance system was to observe at the program decisions from some obstacle conditions read by the camera and ultrasonic sensors. Visual feedback control based PID controllers are used as a control of drones movement. The conclusion of the obstacle avoidance system was to observe at the program decisions from some obstacle conditions read by the camera and ultrasonic sensors.

  10. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  11. A new PID controller design for automatic generation control of hydro power systems

    Energy Technology Data Exchange (ETDEWEB)

    Khodabakhshian, A.; Hooshmand, R. [Electrical Engineering Department, University of Isfahan (Iran)

    2010-06-15

    This paper presents a new robust PID controller for automatic generation control (AGC) of hydro turbine power systems. The method is mainly based on a maximum peak resonance specification that is graphically supported by the Nichols chart. The open-loop frequency response curve is tangent to a specified ellipse and this makes the method to be efficient for controlling the overshoot, the stability and the dynamics of the system. Comparative results of this new load frequency controller with a conventional PI one and also with another PID controller design tested on a multimachine power system show the improvement in system damping remarkably. The region of acceptable performance of the new PID controller covers a wide range of operating and system conditions. (author)

  12. Automatic alternative phase-shift mask CAD layout tool for gate shrinkage of embedded DRAM in logic below 0.18 μm

    Science.gov (United States)

    Ohnuma, Hidetoshi; Kawahira, Hiroichi

    1998-09-01

    An automatic alternative phase shift mask (PSM) pattern layout tool has been newly developed. This tool is dedicated for embedded DRAM in logic device to shrink gate line width with improving line width controllability in lithography process with a design rule below 0.18 micrometers by the KrF excimer laser exposure. The tool can crete Levenson type PSM used being coupled with a binary mask adopting a double exposure method for positive photo resist. By using graphs, this tool automatically creates alternative PSM patterns. Moreover, it does not give any phase conflicts. By adopting it to actual embedded DRAM in logic cells, we have provided 0.16 micrometers gate resist patterns at both random logic and DRAM areas. The patterns were fabricated using two masks with the double exposure method. Gate line width has been well controlled under a practical exposure-focus window.

  13. The application of PLC automatic control system for resin transfer in pulsed elution

    International Nuclear Information System (INIS)

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  14. Automatic and controlled processing and the Broad Autism Phenotype.

    Science.gov (United States)

    Camodeca, Amy; Voelker, Sylvia

    2016-01-30

    Research related to verbal fluency in the Broad Autism Phenotype (BAP) is limited and dated, but generally suggests intact abilities in the context of weaknesses in other areas of executive function (Hughes et al., 1999; Wong et al., 2006; Delorme et al., 2007). Controlled processing, the generation of search strategies after initial, automated responses are exhausted (Spat, 2013), has yet to be investigated in the BAP, and may be evidenced in verbal fluency tasks. One hundred twenty-nine participants completed the Delis-Kaplan Executive Function System Verbal Fluency test (D-KEFS; Delis et al., 2001) and the Broad Autism Phenotype Questionnaire (BAPQ; Hurley et al., 2007). The BAP group (n=53) produced significantly fewer total words during the 2nd 15" interval compared to the Non-BAP (n=76) group. Partial correlations indicated similar relations between verbal fluency variables for each group. Regression analyses predicting 2nd 15" interval scores suggested differentiation between controlled and automatic processing skills in both groups. Results suggest adequate automatic processing, but slowed development of controlled processing strategies in the BAP, and provide evidence for similar underlying cognitive constructs for both groups. Controlled processing was predictive of Block Design score for Non-BAP participants, and was predictive of Pragmatic Language score on the BAPQ for BAP participants. These results are similar to past research related to strengths and weaknesses in the BAP, respectively, and suggest that controlled processing strategy use may be required in instances of weak lower-level skills. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. A Flexible and Configurable Architecture for Automatic Control Remote Laboratories

    Science.gov (United States)

    Kalúz, Martin; García-Zubía, Javier; Fikar, Miroslav; Cirka, Luboš

    2015-01-01

    In this paper, we propose a novel approach in hardware and software architecture design for implementation of remote laboratories for automatic control. In our contribution, we show the solution with flexible connectivity at back-end, providing features of multipurpose usage with different types of experimental devices, and fully configurable…

  16. Automatic Tuning of the Superheat Controller in a Refrigeration Plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Thybo, Claus; Larsen, Lars F. S.

    2006-01-01

    This paper proposes an automatic tuning of the superheat control in a refrigeration system using a relay method. By means of a simple evaporator model that captures the important dynamics and non-linearities of the superheat a gain-scheduling that compensates for the variation of the process gain...

  17. Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study.

    Science.gov (United States)

    Di Leo, Giovanni; Spadavecchia, Chiara; Zanardo, Moreno; Secchi, Francesco; Veronese, Ivan; Cantone, Marie Claire; Sardanelli, Francesco

    2017-07-01

    To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. • CT-AEC system is not impaired in patients with endoaortic prostheses/heart valves. • Negligible differences may be observed only at 120 kVp. • Disabling the AEC system in these patients is not recommended.

  18. Automatic performance estimation of conceptual temperature control system design for rapid development of real system

    International Nuclear Information System (INIS)

    Jang, Yu Jin

    2013-01-01

    This paper presents an automatic performance estimation scheme of conceptual temperature control system with multi-heater configuration prior to constructing the physical system for achieving rapid validation of the conceptual design. An appropriate low-order discrete-time model, which will be used in the controller design, is constructed after determining several basic factors including the geometric shape of controlled object and heaters, material properties, heater arrangement, etc. The proposed temperature controller, which adopts the multivariable GPC (generalized predictive control) scheme with scale factors, is then constructed automatically based on the above model. The performance of the conceptual temperature control system is evaluated by using a FEM (finite element method) simulation combined with the controller.

  19. Automatic performance estimation of conceptual temperature control system design for rapid development of real system

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yu Jin [Dongguk University, GyeongJu (Korea, Republic of)

    2013-07-15

    This paper presents an automatic performance estimation scheme of conceptual temperature control system with multi-heater configuration prior to constructing the physical system for achieving rapid validation of the conceptual design. An appropriate low-order discrete-time model, which will be used in the controller design, is constructed after determining several basic factors including the geometric shape of controlled object and heaters, material properties, heater arrangement, etc. The proposed temperature controller, which adopts the multivariable GPC (generalized predictive control) scheme with scale factors, is then constructed automatically based on the above model. The performance of the conceptual temperature control system is evaluated by using a FEM (finite element method) simulation combined with the controller.

  20. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    Directory of Open Access Journals (Sweden)

    Mahammad A. Hannan

    2014-12-01

    Full Text Available With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil’s mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning

  1. Automatic Frequency Controller for Power Amplifiers Used in Bio-Implanted Applications: Issues and Challenges

    Science.gov (United States)

    Hannan, Mahammad A.; Hussein, Hussein A.; Mutashar, Saad; Samad, Salina A.; Hussain, Aini

    2014-01-01

    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of

  2. Development of remote automatic equipment for BWR power plants

    International Nuclear Information System (INIS)

    Sasaki, Masayoshi

    1984-01-01

    The development of remote control, automatic equipment for nuclear power stations has been promoted to raise the rate of operation of plants by shortening regular inspection period, to improve the safety and reliability of inspection and maintenance works by mechanization, to reduce the radiation exposure dose of workers and to reduce the manpower required for works. The taking-off of control rod drives from reactors and fixing again have been mechanized, but the disassembling, cleaning, inspection and assembling of control rod drives are manually carried out. Therefore, Hitachi Ltd. has exerted effort to develop the automatic equipment for this purpose. The target of development, investigation, the construction and function of the equipment, the performance and the effect of adopting it are reported. The equipment for the volume reduction of spent fuel channel boxes and spent control rods is developed since these are major high level radioactive solid wastes, and their apparent volume is large. Also the target of development, investigated things, the construction and function of the equipment, the performance and the effect of adopting it are reported. (Kako, I.)

  3. Computer program for automatic generation of BWR control rod patterns

    International Nuclear Information System (INIS)

    Taner, M.S.; Levine, S.H.; Hsia, M.Y.

    1990-01-01

    A computer program named OCTOPUS has been developed to automatically determine a control rod pattern that approximates some desired target power distribution as closely as possible without violating any thermal safety or reactor criticality constraints. The program OCTOPUS performs a semi-optimization task based on the method of approximation programming (MAP) to develop control rod patterns. The SIMULATE-E code is used to determine the nucleonic characteristics of the reactor core state

  4. Effect of automatic recirculation flow control on the transient response for Lungmen ABWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Tzang, Y.-C., E-mail: yctzang@aec.gov.t [National Tsing Hua University, Department of Engineering and System Science, Hsinchu 30013, Taiwan (China); Chiang, R.-F.; Ferng, Y.-M.; Pei, B.-S. [National Tsing Hua University, Department of Engineering and System Science, Hsinchu 30013, Taiwan (China)

    2009-12-15

    In this study the automatic mode of the recirculation flow control system (RFCS) for the Lungmen ABWR plant has been modeled and incorporated into the basic RETRAN-02 system model. The integrated system model is then used to perform the analyses for the two transients in which the automatic RFCS is involved. The two transients selected are: (1) one reactor internal pump (RIP) trip, and (2) loss of feedwater heating. In general, the integrated system model can predict well the response of key system parameters, including neutron flux, steam dome pressure, heat flux, RIP flow, core inlet flow, feedwater flow, steam flow, and reactor water level. The transients are also analyzed for manual RFCS case, between the automatic RFCS and the manual RFCS cases, comparisons of the transient response for the key system parameter show that the difference of transient response can be clearly identified. Also, the results show that the DELTACPR (delta critical power ratio) for the transients analyzed may not be less limiting for the automatic RFCS case under certain combination of control system settings.

  5. Children’s Behavioral Pain Cues: Implicit Automaticity and Control Dimensions in Observational Measures

    Directory of Open Access Journals (Sweden)

    Kamal Kaur Sekhon

    2017-01-01

    Full Text Available Some pain behaviors appear to be automatic, reflexive manifestations of pain, whereas others present as voluntarily controlled. This project examined whether this distinction would characterize pain cues used in observational pain measures for children aged 4–12. To develop a comprehensive list of cues, a systematic literature search of studies describing development of children’s observational pain assessment tools was conducted using MEDLINE, PsycINFO, and Web of Science. Twenty-one articles satisfied the criteria. A total of 66 nonredundant pain behavior items were identified. To determine whether items would be perceived as automatic or controlled, 277 research participants rated each on multiple scales associated with the distinction. Factor analyses yielded three major factors: the “Automatic” factor included items related to facial expression, paralinguistics, and consolability; the “Controlled” factor included items related to intentional movements, verbalizations, and social actions; and the “Ambiguous” factor included items related to voluntary facial expressions. Pain behaviors in observational pain scales for children can be characterized as automatic, controlled, and ambiguous, supporting a dual-processing, neuroregulatory model of pain expression. These dimensions would be expected to influence judgments of the nature and severity of pain being experienced and the extent to which the child is attempting to control the social environment.

  6. AUTOMATIC CONTROL OF PARAMETERS OF A NON-STATIONARY OBJECT WITH CROSS LINKS

    Directory of Open Access Journals (Sweden)

    A. Pavlov

    2018-04-01

    Full Text Available Many objects automatic control unsteady. This is manifested in the change of their parameters. Therefore, periodically adjust the required parameters of the controller. This work is usually carried out rarely. For a long time, regulators are working with is not the optimal settings. The consequence of this is the low quality of many industrial control systems. The solution problem is the use of robust controllers. ACS with traditional PI and PID controllers have a very limited range of normal operation modes due to the appearance of parametric disturbances due to changes in the characteristics of the automated unit and changes in the load on it. The situation is different when using in the architecture of artificial neural network controllers. It is known that when training a neural network, the adaptation procedure is often used. This makes it possible to greatly expand the area of normal operating modes of ACS with neural automatic regulators in comparison with traditional linear regulators. It is also possible to significantly improve the quality of control (especially for a non-stationary multidimensional object, provided that when designing the ACS at the stage of its simulation in the model of the regulatory object model, an adequate simulation model of the executive device. It is also possible to significantly improve the quality of control (especially for a non-stationary multidimensional regulatory object model, an adequate simulation model of the executive device. Especially actual implementation of all these requirements in the application of electric actuators. This article fully complies with these requirements. This is what makes it possible to provide a guaranteed quality of control in non-stationary ACS with multidimensional objects and cross-links between control channels. The possibility of using a known hybrid automatic regulator to stabilize the parameters of a two-channel non-stationary object with two cross-linked. A

  7. Automatic charge control system for satellites

    Science.gov (United States)

    Shuman, B. M.; Cohen, H. A.

    1985-01-01

    The SCATHA and the ATS-5 and 6 spacecraft provided insights to the problem of spacecraft charging at geosychronous altitudes. Reduction of the levels of both absolute and differential charging was indicated, by the emission of low energy neutral plasma. It is appropriate to complete the transition from experimental results to the development of a system that will sense the state-of-charge of a spacecraft, and, when a predetermined threshold is reached, will respond automatically to reduce it. A development program was initiated utilizing sensors comparable to the proton electrostatic analyzer, the surface potential monitor, and the transient pulse monitor that flew in SCATHA, and combine these outputs through a microprocessor controller to operate a rapid-start, low energy plasma source.

  8. An automatic device for the quality control of large-scale crystal's production

    CERN Document Server

    Baccaro, S; Castellani, M; Cecilia, A; Dafinei, I; Diemoz, M; Guerra, S; Longo, E; Montecchi, M; Organtini, G; Pellegrini, F

    2001-01-01

    In 1999, the construction of the electromagnetic calorimeter of the Compact Muon Solenoid (CMS) experiment started. Half of the barrel calorimeter made of 61200 lead tungstate (PWO) crystals will be assembled and tested in the Regional Centre of INFN-ENEA in Rome, Italy. Before assembling, all 30600 PWO crystals will be qualified for scintillation and radiation hardness characteristics by a specially built Automatic Crystal Control System. The measuring techniques for crystal qualification and performances of the automatic system will be discussed in this work. (11 refs).

  9. A full automatic system controlled with IBM-PC/XT micro-computer for neutron activation analysis

    International Nuclear Information System (INIS)

    Song Quanxun

    1992-01-01

    A full automatic system controlled with micro-computers for NAA is described. All processes are automatically completed with an IBM-PC/XT micro-computer. The device is stable, reliable, flexible and convenient for use and has many functions and applications in automatical analysis of long, middle and short lived nuclides. Due to a high working efficiency of the instrument and micro-computers, both time and power can be saved. This method can be applied in other nuclear analysis techniques

  10. An Automatic Control System for Conditioning 30 GHz Accelerating Structures

    CERN Document Server

    Dubrovskiy, A

    2008-01-01

    A software application programme has been developed to allow fast and automatic high-gradient conditioning of accelerating structures at 30 GHz in CTF3. The specificity of the application is the ability to control the high-power electron beam which produces the 30 GHz RF power used to condition the accelerating structures. The programme permits operation round the clock with minimum manpower requirements. In this paper the fast control system, machine control system, logging system, graphical user control interface and logging data visualization are described. An outline of the conditioning control system itself and of the feedback controlling peak power and pulse length is given. The software allows different types of conditioning strategies to be programmed

  11. Hybrid Control of a Two-Wheeled Automatic-Balancing Robot with Backlash Feature

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Yang, Zhenyu

    2013-01-01

    This paper investigates the application of hybrid control for an automatic balancing robot system subject to backlash effect. The developed controller is a type of sliding mode controller, refereed to as a switching controller, with respect to different situations i.e., whether the backlash is pr...... and comparisons with other solutions show the proposed solution can lead to a very satisfactory anti-backlash performance, with an easy and cost-effective implementation....

  12. Automatic combustion control of the ArcelorMittal Tubarao coke oven batteries

    Energy Technology Data Exchange (ETDEWEB)

    L. Barbosa de Oliveira Mello; C.-H. Sampaio Dandrea; G.-H. Marietto Goncalves; A. Estevao Torres; N.-L. Biccas

    2008-05-15

    The objective of the automatic combustion control is to guarantee the operational stability of the coke batteries based on the control of the coking time and consequently, minimize the reduction of useful life of the ovens. This control is guided by a mathematical model whose inputs are process variables and raw materials parameters and outputs are combustion parameters. Therefore, this paper will present the evolution of the performance of the burning process, providing a stability of the coking time.

  13. Automatic Control Systems (ACS for Generation and Sale of Electric Power Under Conditions of Industry-Sector Liberalization

    Directory of Open Access Journals (Sweden)

    Yu. S. Petrusha

    2013-01-01

    Full Text Available Possible risks pertaining to transition of electric-power industry to market relations have been considered in the paper. The paper presents an integrated ACS for generation and sale of electric power as an improvement of methodology for organizational and technical management. The given system is based on integration of operating Automatic Dispatch Control System (ADCS and developing Automatic Electricity Meter Reading System (AEMRS. The paper proposes to form an inter-branch sector of ACS PLC (Automatic Control System for Prolongation of Life Cycle users which is oriented on provision of development strategy.

  14. Control method and device for automatic drift stabilization in radiation detection

    International Nuclear Information System (INIS)

    Berthold, F.; Kubisiak, H.

    1979-01-01

    In the automatic control circuit individual electron peaks in the detectors, e.g. NaI crystals or proportional counters, are used. These peaks exhibit no drift dependence; they may be produced in the detectors in different ways. The control circuit may be applied in nuclear radiation measurement techniques, photometry, gamma cameras and for measuring the X-ray fine structure with proportional counters. (DG) [de

  15. Automatic Lamp and Fan Control Based on Microcontroller

    Science.gov (United States)

    Widyaningrum, V. T.; Pramudita, Y. D.

    2018-01-01

    In general, automation can be described as a process following pre-determined sequential steps with a little or without any human exertion. Automation is provided with the use of various sensors suitable to observe the production processes, actuators and different techniques and devices. In this research, the automation system developed is an automatic lamp and an automatic fan on the smart home. Both of these systems will be processed using an Arduino Mega 2560 microcontroller. A microcontroller is used to obtain values of physical conditions through sensors connected to it. In the automatic lamp system required sensors to detect the light of the LDR (Light Dependent Resistor) sensor. While the automatic fan system required sensors to detect the temperature of the DHT11 sensor. In tests that have been done lamps and fans can work properly. The lamp can turn on automatically when the light begins to darken, and the lamp can also turn off automatically when the light begins to bright again. In addition, it can concluded also that the readings of LDR sensors are placed outside the room is different from the readings of LDR sensors placed in the room. This is because the light intensity received by the existing LDR sensor in the room is blocked by the wall of the house or by other objects. Then for the fan, it can also turn on automatically when the temperature is greater than 25°C, and the fan speed can also be adjusted. The fan may also turn off automatically when the temperature is less than equal to 25°C.

  16. Remote automatic control scheme for plasma arc cutting of contaminated waste

    International Nuclear Information System (INIS)

    Dudar, A.M.; Ward, C.R.; Kriikku, E.M.

    1993-01-01

    The Robotics Development Group at the Savannah River Technology Center has developed and implemented a scheme to perform automatic cutting of metallic contaminated waste. The scheme employs a plasma arc cutter in conjunction with a laser ranging sensor attached to a robotic manipulator called the Telerobot. A software algorithm using proportional control is then used to perturb the robot's trajectory in such a way as to regulate the plasma arc standoff and the robot's speed in order to achieve automatic plasma arc cuts. The scheme has been successfully tested on simulated waste materials and the results have been very favorable. This report details the development and testing of the scheme

  17. Automatic segmentation of the lateral geniculate nucleus: Application to control and glaucoma patients.

    Science.gov (United States)

    Wang, Jieqiong; Miao, Wen; Li, Jing; Li, Meng; Zhen, Zonglei; Sabel, Bernhard; Xian, Junfang; He, Huiguang

    2015-11-30

    The lateral geniculate nucleus (LGN) is a key relay center of the visual system. Because the LGN morphology is affected by different diseases, it is of interest to analyze its morphology by segmentation. However, existing LGN segmentation methods are non-automatic, inefficient and prone to experimenters' bias. To address these problems, we proposed an automatic LGN segmentation algorithm based on T1-weighted imaging. First, the prior information of LGN was used to create a prior mask. Then region growing was applied to delineate LGN. We evaluated this automatic LGN segmentation method by (1) comparison with manually segmented LGN, (2) anatomically locating LGN in the visual system via LGN-based tractography, (3) application to control and glaucoma patients. The similarity coefficients of automatic segmented LGN and manually segmented one are 0.72 (0.06) for the left LGN and 0.77 (0.07) for the right LGN. LGN-based tractography shows the subcortical pathway seeding from LGN passes the optic tract and also reaches V1 through the optic radiation, which is consistent with the LGN location in the visual system. In addition, LGN asymmetry as well as LGN atrophy along with age is observed in normal controls. The investigation of glaucoma effects on LGN volumes demonstrates that the bilateral LGN volumes shrink in patients. The automatic LGN segmentation is objective, efficient, valid and applicable. Experiment results proved the validity and applicability of the algorithm. Our method will speed up the research on visual system and greatly enhance studies of different vision-related diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. DISTURBANCE ERROR INVARIANCE IN AUTOMATIC CONTROL SYSTEMS FOR TECHNOLOGICAL OBJECT TRAJECTORY MOVEMENT

    Directory of Open Access Journals (Sweden)

    A. V. Lekareva

    2016-09-01

    Full Text Available We consider combined control in automatic control systems for technological objects trajectory movements. We present research results of the system disturbance invariance ensuring on the example of the technological manipulator that implements hydrocutting of the oil pipelines. Control is based on the propositions of the fourth modified invariance form with the use of bootstrapping methods. The paper presents analysis of results obtained by two different correction methods. The essence of the first method lies in injection of additional component into the already established control signal and formation of the channel for that component. Control signal correction during the signal synthesis stage in the control device constitutes the basis for the second method. Research results have shown high efficiency of application for both correction methods. Both methods have roughly the same precision. We have shown that the correction in the control device is preferable because it has no influence on the inner contour of the system. We have shown the necessity of the block usage with the variable transmission coefficient, which value is determined by technological trajectory parameters. Research results can be applied in practice for improvement of the precision specifications of automatic control systems for trajectorial manipulators.

  19. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  20. Effect of local automatic control rods on three-dimensional calculations of the power distribution in an RBMK

    International Nuclear Information System (INIS)

    Pogosbekyan, L.R.; Lysov, D.A.; Bronitskii, L.L.

    1993-01-01

    Numerical simulators and information systems that support nuclear reactor operators must have fast models to estimate how fuel reloads and control rod displacement affect neutron and power distributions in the core. The consequences of reloads and control rod displacement cannot be evaluated correctly without considering local automatic control-rod operations in maintaining the radial power distribution. Fast three-dimensional models to estimate the effects of reloads and displacement of the control and safety rods have already been examined. I.V. Zonov et al. used the following assumptions in their calculational model: (1) the full-scale problem could be reduced a three-dimensional fragment of a locally perturbed core, and (2) the boundary conditions of the fragment and its total power were constant. The last assumption considers approximately how local automatic control rods stabilize the radial power distribution, but three dimensional calculations with these rods are not considered. These assumptions were introduced to obtain high computational speed. I.L. Bronitskii et al. considered in more detail how moving the local automatic control rods affect the power dimensional in the three-dimensional fragment, because, with on-line monitoring of the reload process, information on control rod positions is periodically renewed, and the calculations are done in real time. This model to predict the three-dimensional power distribution to (1) do a preliminary reload analysis, and (2) prepare the core for reloading did not consider the effect of perturbations from the local automatic control rods. Here we examine a model of a stationary neutron distribution. On one hand it gives results in an acceptable computation time; on the other it is a full-scale three-dimensional model and considers how local automatic control rods affect both the radial and axial power distribution

  1. Development of automatic control method for cryopump system for JT-60 neutral beam injector

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Akino, Noboru; Dairaku, Masayuki; Ohuchi, Yutaka; Shibata, Takemasa

    1991-10-01

    A cryopump system for JT-60 neutral beam injector (NBI) is composed of 14 cryopumps with the largest total pumping speed of 20000 m 3 /s in the world, which are cooled by liquid helium through a long-distance liquid helium transferline of about 500 m from a helium refrigerator with the largest capacity of 3000 W at 3.6 K in Japan. An automatic control method of the cryopump system has been developed and tested. Features of the automatic control method are as follows. 1) Suppression control of the thermal imbalance in cooling-down of the 14 cryopumps. 2) Stable cooling control of the cryopump due to liquid helium supply to six cryopanels by natural circulation in steady-state mode. 3) Stable liquid helium supply control for the cryopumps from the liquid helium dewar in all operation modes of the cryopumps, considering the helium quantities held in respective components of the closed helium loop. 4) Stable control of the helium refrigerator for the fluctuation in thermal load from the cryopumps and the change of operation mode of the cryopumps. In the automatic operation of the cryopump system by the newly developed control method, the cryopump system including the refrigerator was stably operated for all operation modes of the cryopumps, so that the cool-down of 14 cryopumps was completed in 16 hours from the start of cool-down of the system and the cryopumps was stably cooled by natural circulation cooling in steady-state mode. (author)

  2. Automatic and controlled components of judgment and decision making

    OpenAIRE

    Ferreira, MB; Garcia-Marques, L; Sherman, SJ; Sherman, JW

    2006-01-01

    The categorization of inductive reasoning into largely automatic processes (heuristic reasoning) and controlled analytical processes (rule-based reasoning) put forward by dual-process approaches of judgment under uncertainty (e.g., K. E. Stanovich & R. F. West, 2000) has been primarily a matter of assumption with a scarcity of direct empirical findings supporting it. The present authors use the process dissociation procedure (L. L. Jacoby, 1991) to provide convergent evidence validating a d...

  3. Personal exposure control using TLD

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu; Takeda, Shinso

    1979-01-01

    In the Tokai Works of the Power Reactor and Nuclear Fuel Development Corporation (PNC), for personal exposure control, the switching from film badges to TLD badges (and also finger-ring type local dosimeters) was made in fiscal 1974. The facilities involved are a fuel reprocessing plant, a PuO 2 -UO 2 mixed fuel production facility, and a centrifugal uranium enrichment development facility. The types of radiation concerned are various, such as γ(x), β and n. The situation of personal exposure control with TLD and the dose evaluation methods for respective radiations are explained. The number of personnel subject to exposure control, including transient people, is about 2500 - 3000 per three months. The TLD badges used are a special PNC type with TLDs to measure separately γ(x), β and n. With casings made of ABS resin, the external dimensions are 76 mm x 46 mm. (J.P.N.)

  4. Position automatic determination technology

    International Nuclear Information System (INIS)

    1985-10-01

    This book tells of method of position determination and characteristic, control method of position determination and point of design, point of sensor choice for position detector, position determination of digital control system, application of clutch break in high frequency position determination, automation technique of position determination, position determination by electromagnetic clutch and break, air cylinder, cam and solenoid, stop position control of automatic guide vehicle, stacker crane and automatic transfer control.

  5. Design of automatic control and measurement software for radioactive aerosol continuity monitor

    International Nuclear Information System (INIS)

    Mao Yong; Li Aiwu

    1997-01-01

    The radioactive aerosol continuity measurement is very important for the development of nuclear industry, and it is the major method to measure and find out the leakage of radioactive material. Radioactive aerosol continuity monitor is the advanced method for the radioactive aerosol continuity measurement. With the development of nuclear industry and nuclear power station, it is necessary to design and automatic continuity measurement device. Because of this reason, the authors developed the first unit of radioactive aerosol continuity monitor and adopted the ministry appraisal. The design idea and method of automatic control and measurement for radioactive aerosol continuity monitor are discussed

  6. Automatic alignment device for focal spot measurements in the center of the field for mammography

    International Nuclear Information System (INIS)

    Vieira, Marcelo A.C.; Watanabe, Alex O.; Oliveira Junior, Paulo D.; Schiabel, Homero

    2010-01-01

    Some quality control procedures used for mammography, such as focal spot evaluation, requires previous alignment of the measurement equipment with the X-ray central beam. However, alignment procedures are, in general, the most difficult task and the one that needs more time to be performed. Moreover, the operator sometimes is exposed to radiation during this procedure. This work presents an automatic alignment system for mammographic equipment that allows locating the central ray of the radiation beam and, immediately, aligns with it by dislocating itself automatically along the field. The system consists on a bidirectional moving device, connected to a CCD sensor for digital radiographic image acquisition. A computational analysis of a radiographic image, acquired at any position on the field, is performed in order to determine its positioning under the X-ray beam. Finally, a mechanical system for two moving directions, electronically controlled by a microcontroller under USB communication, makes the system to align automatically with the radiation beam central ray. The alignment process is fully automatic, fast and accurate, with no operator exposure to radiation, which allows a considerable time saving for quality control procedures achievement for mammography. (author)

  7. Automatic Control of Reactor Temperature and Power Distribution for a Daily Load following Operation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Keuk Jong; Kim, Han Gon [Korea Hydro and Nuclear Power Institute, Daejeon (Korea, Republic of)

    2010-10-15

    An automatic control method of reactor power and power distribution was developed for a daily load following operation of APR1400. This method used a model predictive control (MPC) methodology having second-order plant data. And it utilized a reactor power ratio and axial shape index as control variables. However, the reactor regulating system of APR1400 is operated by the difference between the average temperature of the reactor core and the reference temperature, which is proportional to the turbine load. Thus, this paper reports on the model predictive control methodology using fourth-order plant data and a reactor temperature instead of the reactor power shape. The purpose of this study is to develop a revised automatic controller and analyze the behavior of the nuclear reactor temperature (Tavg) and the axial shape index (ASI) using the MPC method during a daily load following operation

  8. The application of charge-coupled device processors in automatic-control systems

    Science.gov (United States)

    Mcvey, E. S.; Parrish, E. A., Jr.

    1977-01-01

    The application of charge-coupled device (CCD) processors to automatic-control systems is suggested. CCD processors are a new form of semiconductor component with the unique ability to process sampled signals on an analog basis. Specific implementations of controllers are suggested for linear time-invariant, time-varying, and nonlinear systems. Typical processing time should be only a few microseconds. This form of technology may become competitive with microprocessors and minicomputers in addition to supplementing them.

  9. Modeling and simulation of the generation automatic control of electric power systems; Modelado y simulacion del control automatico de generacion de sistemas electricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Caballero Ortiz, Ezequiel

    2002-12-01

    This work is devoted to the analysis of the Automatic Control of Electrical Systems Generation of power, as of the information that generates the loop with Load-Frequency Control and the Automatic Voltage Regulator loop. To accomplish the analysis, the control classical theory and feedback control systems concepts are applied. Thus also, the modern theory concepts are employed. The studies are accomplished in the digital computer through the MATLAB program and the available simulation technique in the SIMULINK tool. In this thesis the theoretical and physical concepts of the automatic control of generation are established; dividing it in load frequency control and automatic voltage regulator loops. The mathematical models of the two control loops are established. Later, the models of the elements are interconnected in order to integrate the loop with load frequency control and the digital simulation of the system is carried out. In first instance, the function of the primary control in are - machine, area - multi machine and multi area - multi machine power systems, is analyzed. Then, the automatic control of generation of the area and multi area power systems is studied. The economic dispatch concept is established and with this plan the power system multi area is simulated, there in after the energy exchange among areas in stationary stage is studied. The mathematical models of the component elements of the control loop of the automatic voltage regulator are interconnected. Data according to the nature of each component are generated and their behavior is simulated to analyze the system response. The two control loops are interconnected and a simulation is carry out with data generated previously, examining the performance of the automatic control of generation and the interaction between the two control loops. Finally, the Poles Positioning and the Optimum Control techniques of the modern control theory are applied to the automatic control of an area generation

  10. Neural Bases of Automaticity

    Science.gov (United States)

    Servant, Mathieu; Cassey, Peter; Woodman, Geoffrey F.; Logan, Gordon D.

    2018-01-01

    Automaticity allows us to perform tasks in a fast, efficient, and effortless manner after sufficient practice. Theories of automaticity propose that across practice processing transitions from being controlled by working memory to being controlled by long-term memory retrieval. Recent event-related potential (ERP) studies have sought to test this…

  11. Using Automatic Code Generation in the Attitude Control Flight Software Engineering Process

    Science.gov (United States)

    McComas, David; O'Donnell, James R., Jr.; Andrews, Stephen F.

    1999-01-01

    This paper presents an overview of the attitude control subsystem flight software development process, identifies how the process has changed due to automatic code generation, analyzes each software development phase in detail, and concludes with a summary of our lessons learned.

  12. A Semi-Automatic, Remote-Controlled Video Observation System for Transient Luminous Events

    DEFF Research Database (Denmark)

    Allin, Thomas Højgaard; Neubert, Torsten; Laursen, Steen

    2003-01-01

    In support for global ELF/VLF observations, HF measurements in France, and conjugate photometry/VLF observations in South Africa, we developed and operated a semi-automatic, remotely controlled video system for the observation of middle-atmospheric transient luminous events (TLEs). Installed...

  13. Improving labeling efficiency in automatic quality control of MRSI data.

    Science.gov (United States)

    Pedrosa de Barros, Nuno; McKinley, Richard; Wiest, Roland; Slotboom, Johannes

    2017-12-01

    To improve the efficiency of the labeling task in automatic quality control of MR spectroscopy imaging data. 28'432 short and long echo time (TE) spectra (1.5 tesla; point resolved spectroscopy (PRESS); repetition time (TR)= 1,500 ms) from 18 different brain tumor patients were labeled by two experts as either accept or reject, depending on their quality. For each spectrum, 47 signal features were extracted. The data was then used to run several simulations and test an active learning approach using uncertainty sampling. The performance of the classifiers was evaluated as a function of the number of patients in the training set, number of spectra in the training set, and a parameter α used to control the level of classification uncertainty required for a new spectrum to be selected for labeling. The results showed that the proposed strategy allows reductions of up to 72.97% for short TE and 62.09% for long TE in the amount of data that needs to be labeled, without significant impact in classification accuracy. Further reductions are possible with significant but minimal impact in performance. Active learning using uncertainty sampling is an effective way to increase the labeling efficiency for training automatic quality control classifiers. Magn Reson Med 78:2399-2405, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. The N400 and Late Positive Complex (LPC Effects Reflect Controlled Rather than Automatic Mechanisms of Sentence Processing

    Directory of Open Access Journals (Sweden)

    Boris Kotchoubey

    2012-08-01

    Full Text Available This study compared automatic and controlled cognitive processes that underlie event-related potentials (ERPs effects during speech perception. Sentences were presented to French native speakers, and the final word could be congruent or incongruent, and presented at one of four levels of degradation (using a modulation with pink noise: no degradation, mild degradation (2 levels, or strong degradation. We assumed that degradation impairs controlled more than automatic processes. The N400 and Late Positive Complex (LPC effects were defined as the differences between the corresponding wave amplitudes to incongruent words minus congruent words. Under mild degradation, where controlled sentence-level processing could still occur (as indicated by behavioral data, both N400 and LPC effects were delayed and the latter effect was reduced. Under strong degradation, where sentence processing was rather automatic (as indicated by behavioral data, no ERP effect remained. These results suggest that ERP effects elicited in complex contexts, such as sentences, reflect controlled rather than automatic mechanisms of speech processing. These results differ from the results of experiments that used word-pair or word-list paradigms.

  15. Automatic Overset Grid Generation with Heuristic Feedback Control

    Science.gov (United States)

    Robinson, Peter I.

    2001-01-01

    An advancing front grid generation system for structured Overset grids is presented which automatically modifies Overset structured surface grids and control lines until user-specified grid qualities are achieved. The system is demonstrated on two examples: the first refines a space shuttle fuselage control line until global truncation error is achieved; the second advances, from control lines, the space shuttle orbiter fuselage top and fuselage side surface grids until proper overlap is achieved. Surface grids are generated in minutes for complex geometries. The system is implemented as a heuristic feedback control (HFC) expert system which iteratively modifies the input specifications for Overset control line and surface grids. It is developed as an extension of modern control theory, production rules systems and subsumption architectures. The methodology provides benefits over the full knowledge lifecycle of an expert system for knowledge acquisition, knowledge representation, and knowledge execution. The vector/matrix framework of modern control theory systematically acquires and represents expert system knowledge. Missing matrix elements imply missing expert knowledge. The execution of the expert system knowledge is performed through symbolic execution of the matrix algebra equations of modern control theory. The dot product operation of matrix algebra is generalized for heuristic symbolic terms. Constant time execution is guaranteed.

  16. Controlling the COD removal of an A-stage pilot study with instrumentation and automatic process control.

    Science.gov (United States)

    Miller, Mark W; Elliott, Matt; DeArmond, Jon; Kinyua, Maureen; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B

    2017-06-01

    The pursuit of fully autotrophic nitrogen removal via the anaerobic ammonium oxidation (anammox) pathway has led to an increased interest in carbon removal technologies, particularly the A-stage of the adsorption/bio-oxidation (A/B) process. The high-rate operation of the A-stage and lack of automatic process control often results in wide variations of chemical oxygen demand (COD) removal that can ultimately impact nitrogen removal in the downstream B-stage process. This study evaluated the use dissolved oxygen (DO) and mixed liquor suspended solids (MLSS) based automatic control strategies through the use of in situ on-line sensors in the A-stage of an A/B pilot study. The objective of using these control strategies was to reduce the variability of COD removal by the A-stage and thus the variability of the effluent C/N. The use of cascade DO control in the A-stage did not impact COD removal at the conditions tested in this study, likely because the bulk DO concentration (>0.5 mg/L) was maintained above the half saturation coefficient of heterotrophic organisms for DO. MLSS-based solids retention time (SRT) control, where MLSS was used as a surrogate for SRT, did not significantly reduce the effluent C/N variability but it was able to reduce COD removal variation in the A-stage by 90%.

  17. The automatic pelvic floor muscle response to the active straight leg raise in cases with pelvic girdle pain and matched controls.

    Science.gov (United States)

    Stuge, Britt; Sætre, Kaja; Ingeborg Hoff, Brækken

    2013-08-01

    The active straight leg raise (ASLR) test has been proposed as a clinical test for the assessment of pelvic girdle pain (PGP). Little is known about the activation of the pelvic floor muscles (PFM) during ASLR. The main aim of this study was to examine the automatic PFM contraction during ASLR. Specific aims were to compare automatic contraction to rest and to voluntary contraction, to compare PFM contraction during ASLR with and without compression and to examine whether there were any differences in PFM contraction between women with and without clinically diagnosed PGP during ASLR. Forty-nine pairs of women participated in a cross-sectional study with individual, one-to-one matched cases and controls. PFM was assessed by reliable and valid 3D ultrasound at rest, during voluntary and automatic contraction. Test-retest data for the levator hiatus during ASLR showed good repeatability. Significantly automatic PFM contractions occurred when ASLR tests were performed. There was a strong positive correlation between voluntary and automatic PFM contractions. Manual compression reduced the automatic PFM contraction during ASLR by 62-66%. There were no significant differences between cases and controls in reduction of levator hiatus or muscle length from rest to automatic contractions during ASLR. Interestingly, a significantly smaller levator hiatus was found in women with PGP than in controls, at rest, during an automatic contraction with ASLR and during voluntary contraction. In conclusion, a significant automatic PFM contraction occurred during ASLR, both in cases and in controls. Women with PGP had a significantly smaller levator hiatus than controls. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Cognitive dysfunction in non-demented Parkinson's disease patients : Controlled and automatic behavior

    NARCIS (Netherlands)

    Koerts, Janneke; Leenders, Klaus L.; Brouwer, Wiebo H.

    The evidence with regard to impaired automatic and controlled information processing in non-demented patients with Parkinson's disease (PD) is critically discussed. We use a comprehensive mental schema framework of executive functioning, that is the planning and regulation of behavior in complex

  19. Effects on automatic attention due to exposure to pictures of emotional faces while performing Chinese word judgment tasks.

    Science.gov (United States)

    Junhong, Huang; Renlai, Zhou; Senqi, Hu

    2013-01-01

    Two experiments were conducted to investigate the automatic processing of emotional facial expressions while performing low or high demand cognitive tasks under unattended conditions. In Experiment 1, 35 subjects performed low (judging the structure of Chinese words) and high (judging the tone of Chinese words) cognitive load tasks while exposed to unattended pictures of fearful, neutral, or happy faces. The results revealed that the reaction time was slower and the performance accuracy was higher while performing the low cognitive load task than while performing the high cognitive load task. Exposure to fearful faces resulted in significantly longer reaction times and lower accuracy than exposure to neutral faces on the low cognitive load task. In Experiment 2, 26 subjects performed the same word judgment tasks and their brain event-related potentials (ERPs) were measured for a period of 800 ms after the onset of the task stimulus. The amplitudes of the early component of ERP around 176 ms (P2) elicited by unattended fearful faces over frontal-central-parietal recording sites was significantly larger than those elicited by unattended neutral faces while performing the word structure judgment task. Together, the findings of the two experiments indicated that unattended fearful faces captured significantly more attention resources than unattended neutral faces on a low cognitive load task, but not on a high cognitive load task. It was concluded that fearful faces could automatically capture attention if residues of attention resources were available under the unattended condition.

  20. Automatic Learning of Fine Operating Rules for Online Power System Security Control.

    Science.gov (United States)

    Sun, Hongbin; Zhao, Feng; Wang, Hao; Wang, Kang; Jiang, Weiyong; Guo, Qinglai; Zhang, Boming; Wehenkel, Louis

    2016-08-01

    Fine operating rules for security control and an automatic system for their online discovery were developed to adapt to the development of smart grids. The automatic system uses the real-time system state to determine critical flowgates, and then a continuation power flow-based security analysis is used to compute the initial transfer capability of critical flowgates. Next, the system applies the Monte Carlo simulations to expected short-term operating condition changes, feature selection, and a linear least squares fitting of the fine operating rules. The proposed system was validated both on an academic test system and on a provincial power system in China. The results indicated that the derived rules provide accuracy and good interpretability and are suitable for real-time power system security control. The use of high-performance computing systems enables these fine operating rules to be refreshed online every 15 min.

  1. Design of a computerized application for the quality control of film automatic processors

    International Nuclear Information System (INIS)

    Merillas del Castillo, A.; Guibelalde del Castillo, E.; Fernandez Soto, J.M.; Vano carruana, E.

    1997-01-01

    The description of a free ware software for quality control of film automatic processors in diagnostic radiology developed by the authors is presented (CC-PRO ver 1.0). The application has been developed for using with automatic scanning densitometers, type X-Rite 380, being also able for manual data acquisition. By means of standard sensitometric techniques and the thus developed software, the trend analysis of the sensitometric variables and the film processor diagnostic could be carried out with an important production improvement, easy management and test consistency. (Author) 6 refs

  2. Studies and Proposals for an Automatic Crystal Control System

    CERN Document Server

    Drobychev, Gleb; Khruschinsky, A A; Korzhik, Mikhail; Missevitch, Oleg; Oriboni, André; Peigneux, Jean-Pierre; Schneegans, Marc

    1997-01-01

    This document presents the status of the studies for an Automatic Crystal Control System ( ACCOS) performed since autumn 1995 for the CMS collaboration. Evaluation of a startstop method for light yield, light uniformity and decay time measurements of PbWO4 crystals is presented, as well as the first results obtained with a compact double-beam spectrophotometer for transverse transmission. Various overall schemes are proposed for an integrated set-up including crystal dimension measurement. The initial financial evaluationperformed is also given.

  3. Double blind placebo controlled exposure to molds

    DEFF Research Database (Denmark)

    Meyer, H W; Jensen, K A; Nielsen, K F

    2005-01-01

    non-significant, and at the same level as after placebo exposure. The developed exposure system based on the Particle-Field and Laboratory Emission Cell (P-FLEC) makes it possible to deliver a precise and highly controlled dose of mold spores from water-damaged building materials, imitating realistic......The objective was to develop an experimental setup for human exposure to mold spores, and to study the clinical effect of this exposure in sensitive subjects who had previously experienced potentially building-related symptoms (BRS) at work. From three water-damaged schools eight employees....... In conclusion this is, to our knowledge, the first study to successfully conduct a human exposure to a highly controlled dose of fungal material aerosolized directly from wet building materials. This short-term exposure to high concentrations of two different molds induced no more reactions than exposure...

  4. Terminal area automatic navigation, guidance and control research using the Microwave Landing System (MLS). Part 5: Design and development of a Digital Integrated Automatic Landing System (DIALS) for steep final approach using modern control techniques

    Science.gov (United States)

    Halyo, N.

    1983-01-01

    The design and development of a 3-D Digital Integrated Automatic Landing System (DIALS) for the Terminal Configured Vehicle (TCV) Research Aircraft, a B-737-100 is described. The system was designed using sampled data Linear Quadratic Gaussian (LOG) methods, resulting in a direct digital design with a modern control structure which consists of a Kalman filter followed by a control gain matrix, all operating at 10 Hz. DIALS uses Microwave Landing System (MLS) position, body-mounted accelerometers, as well as on-board sensors usually available on commercial aircraft, but does not use inertial platforms. The phases of the final approach considered are the localizer and glideslope capture which may be performed simultaneously, localizer and steep glideslope track or hold, crab/decrab and flare to touchdown. DIALS captures, tracks and flares from steep glideslopes ranging from 2.5 deg to 5.5 deg, selected prior to glideslope capture. Digital Integrated Automatic Landing System is the first modern control design automatic landing system successfully flight tested. The results of an initial nonlinear simulation are presented here.

  5. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  6. Phase control of the transient resonance of the automatic ball balancer

    Science.gov (United States)

    Michalczyk, Jerzy; Pakuła, Sebastian

    2016-05-01

    Hazards related to undesired increases of vibration amplitudes in transient resonance of vibroinsulated rotor systems with automatic ball balancer (ABB) are discussed in the paper. The application of the phase control method with taking into account the limited drive power is proposed for these amplitudes reduction. The high efficiency of this approach is indicated.

  7. Function analysis of automatic power controller in Tianwan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhou Haixiang

    2006-01-01

    The hardware and software design characters of the automatic power controller (APC) in Tianwan NPP are introduced. According to the analysis of the principle and function of the system, both availability and reliability of APC in Tianwan NPP are proved. The paper also supplies some methods on how to design the digital APC system. (authors)

  8. Volitional and automatic control of the hand when reaching to grasp objects.

    Science.gov (United States)

    Chen, Zhongting; Saunders, Jeffrey Allen

    2018-02-26

    When picking up an object, we tend to grasp at contact points that allow a stable grip. Recent studies have demonstrated that appropriate grasp points can be selected during an ongoing movement in response to unexpected perturbations of the target object. In this study, we tested whether such online grip adjustments are automatic responses or can be controlled volitionally. Subjects performed virtual grasping movements toward target 2D shapes that sometimes changed shape or orientation during movement. Unlike in previous studies, the conditions and task requirements discouraged any online adjustments toward the perturbed shapes. In Experiment 1, target shapes were perturbed briefly (200 ms) during movement before reverting to the original shape, and subjects were instructed to ignore the transient perturbations. Despite subjects' intentions, we observed online adjustments of grip orientation that were toward the expected grip axis of the briefly presented shape. In Experiment 2, we added a stop-signal to the grasping task, with target perturbation as the stop cue. We again observed unnecessary online adjustments toward the grip axis of the perturbed shape, with similar latency. Furthermore, the grip adjustments continued after the forward motion of the hand had stopped, indicating that the automatic response to the perturbed target shape co-occurred with the volitional response to the perturbation onset. Our results provide evidence that automatic control mechanisms are used to guide the fingers to appropriate grasp points and suggest that these mechanisms are distinct from those involved with volitional control. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. It's a two-way street: Automatic and controlled processes in children's emotional responses to moral transgressions.

    Science.gov (United States)

    Dys, Sebastian P; Malti, Tina

    2016-12-01

    This study examined children's automatic, spontaneous emotional reactions to everyday moral transgressions and their relations with self-reported emotions, which are more complex and infused with controlled cognition. We presented children ​(N=242 4-, 8-, and 12-year-olds) with six everyday moral transgression scenarios in an experimental setting, and both their spontaneous facial emotional reactions and self-reported emotions in the role of the transgressor were recorded. We found that across age self-reported guilt was positively associated with spontaneous fear, and self-reported anger was positively related to spontaneous sadness. In addition, we found a developmental increase in spontaneous sadness and decrease in spontaneous happiness. These results support the importance of automatic and controlled processes in evoking children's emotional responses to everyday moral transgressions. We conclude by providing potential explanations for how automatic and controlled processes function in children's everyday moral experiences and how these processes may change with age. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Reduced-dose chest CT with 3D automatic exposure control vs. standard chest CT: Quantitative assessment of emphysematous changes in smokers’ lung parenchyma

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Yamazaki, Youichi; Matsumoto, Keiko; Onishi, Yumiko; Takenaka, Daisuke; Yoshikawa, Takeshi; Nishio, Mizuho; Matsumoto, Sumiaki; Murase, Kenya; Nishimura, Yoshihiro

    2012-01-01

    Objectives: To determine the capability of reduced-dose chest CT with three-dimensional (3D) automatic exposure control (AEC) on quantitative assessment of emphysematous change in smoker’ lung parenchyma, compared to standard chest CT. Methods: Twenty consecutive smoker patients (mean age 62.8 years) underwent CT examinations using a standard protocol (150 mAs) and a protocol with 3D-AEC. In this study, the targeted standard deviations number was set to 160. For quantitative assessment of emphysematous change in lung parenchyma in each subject using the standard protocol, a percentage of voxels less than −950 HU in the lung (%LAA −950 ) was calculated. The 3D-AEC protocol's %LAA was computed from of voxel percentages under selected threshold CT value. The differences of radiation doses between these two protocols were evaluated, and %LAAs −950 was compared with the 3D-AEC protocol %LAAs. Results: Mean dose length products were 780.2 ± 145.5 mGy cm (standard protocol), and 192.0 ± 95.9 (3D-AEC protocol). There was significant difference between them (paired Student's t test, p −950 and 3D-AEC protocol %LAAs. In adopting the feasible threshold CT values of the 3D-AEC protocol, the 3D-AEC protocol %LAAs were significantly correlated with %LAAs −950 (r = 0.98, p < 0.001) and limits of agreement from Bland–Altman analysis was 0.52 ± 4.3%. Conclusions: Changing threshold CT values demonstrated that reduced-dose chest CT with 3D-AEC can substitute for the standard protocol in assessments of emphysematous change in smoker’ lung parenchyma.

  11. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    Science.gov (United States)

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  12. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    International Nuclear Information System (INIS)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I.

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (author)

  13. Problems of autonomy in coupled double-circuit systems of modern power plant automatic control systems

    International Nuclear Information System (INIS)

    Bilenko, V.A.; Davydov, N.I.

    1979-01-01

    Studied is the problem of autonomy in multicircuit systems of modern power plant automatic control systems; each part of the system has been carried out using the double-circuit scheme. Presented are the problems of neutralization of coupling between separate channels of power plant automatic control system. The conditions of autonomy in coupled double-circuit systems are obtained. The transfer functions of compensation devices are obtained and the variants of their connecting schemes are presented. Analyzed are possible variants of simplification of the coupled system adjustment process by its reduction to the series of consequent steps without using iteration procedures

  14. Automatic control of human thermal comfort with a liquid-cooled garment

    Science.gov (United States)

    Kuznetz, L. H.

    1977-01-01

    Water cooling in a liquid-cooled garment is used to maintain the thermal comfort of crewmembers during extravehicular activity. The feasibility of a simple control that will operate automatically to maintain the thermal comfort is established. Data on three test subjects are included to support the conclusion that heat balance can be maintained well within allowable medical limits. The controller concept was also successfully demonstrated for ground-based applications and shows potential for any tasks involving the use of liquid-cooled garments.

  15. Automated Biometric Voice-Based Access Control in Automatic Teller Machine (ATM)

    OpenAIRE

    Yekini N.A.; Itegboje A.O.; Oyeyinka I.K.; Akinwole A.K.

    2012-01-01

    An automatic teller machine requires a user to pass an identity test before any transaction can be granted. The current method available for access control in ATM is based on smartcard. Efforts were made to conduct an interview with structured questions among the ATM users and the result proofed that a lot of problems was associated with ATM smartcard for access control. Among the problems are; it is very difficult to prevent another person from attaining and using a legitimate persons card, ...

  16. INVARIAN AUTOMATIC CONTROL SYSTEM, USING THE INTERMEDIATE-FREQUENCY SIGNALS OF HEAT POWER PARAMETERS

    Directory of Open Access Journals (Sweden)

    G. T. Kulakov

    2015-01-01

    Full Text Available The usage of digital micro-processing automatic means allow to use design methods (technique of automatic control systems  more wider, and also to apply optimal ways of control, for example, it is possible to combine the Method of structural-parameter optimization and invariance theory. This method allow to increase essential system speed in processing of task jump and to reduce operation time of outside external disturbance up to two  values of regulated influence, and the usage of invariance principle is based on an additional measuring of the most dangerous perturbation influence and in connection with it the improvement of regulation quality is achieved.In this article the principle of invariance is applied in order to improve greatly external disturbance attack by consumption of over-heated steam. Compensation of disturbance influence on regulated value is achieving by introduction of additional signal on input of correction regulator from output of compensation device, measuring the external disturbance by consumption of over-heated steam.Modeling results of transient processes of cascade system of automatic control (CSAC, on the base of which were realized the unity of these methods, demonstrated the fact that, in processing of external disturbance by consumption of steam, the reduction of maximal dynamic regulation error is six times and cutting of regulation time by 30 % in comparison with CSAC without compensation device of external disturbance. And that is why it leads to the further reduction of maximal dynamic regulation error in processing of external disturbance by consumption of steam, and this allows to improve the quality of control.

  17. Piloted Simulation Evaluation of a Model-Predictive Automatic Recovery System to Prevent Vehicle Loss of Control on Approach

    Science.gov (United States)

    Litt, Jonathan S.; Liu, Yuan; Sowers, Thomas S.; Owen, A. Karl; Guo, Ten-Huei

    2014-01-01

    This paper describes a model-predictive automatic recovery system for aircraft on the verge of a loss-of-control situation. The system determines when it must intervene to prevent an imminent accident, resulting from a poor approach. It estimates the altitude loss that would result from a go-around maneuver at the current flight condition. If the loss is projected to violate a minimum altitude threshold, the maneuver is automatically triggered. The system deactivates to allow landing once several criteria are met. Piloted flight simulator evaluation showed the system to provide effective envelope protection during extremely unsafe landing attempts. The results demonstrate how flight and propulsion control can be integrated to recover control of the vehicle automatically and prevent a potential catastrophe.

  18. Automatic Method for Controlling the Iodine Adsorption Number in Carbon Black Oil Furnaces

    Directory of Open Access Journals (Sweden)

    Zečević, N.

    2008-12-01

    Full Text Available There are numerous of different inlet process factors in carbon black oil furnaces which must be continuously and automatically adjusted, due to stable quality of final product. The most important six inlet process factors in carbon black oil-furnaces are:1. volume flow of process air for combustion2. temperature of process air for combustion3. volume flow of natural gas for insurance the necessary heat for thermal reaction of conversionthe hydrocarbon oil feedstock in oil-furnace carbon black4. mass flow rate of hydrocarbon oil feedstock5. type and quantity of additive for adjustment the structure of oil-furnace carbon black6. quantity and position of the quench water for cooling the reaction of oil-furnace carbon black.The control of oil-furnace carbon black adsorption capacity is made with mass flow rate of hydrocarbon feedstock, which is the most important inlet process factor. Oil-furnace carbon black adsorption capacity in industrial process is determined with laboratory analyze of iodine adsorption number. It is shown continuously and automatically method for controlling iodine adsorption number in carbon black oil-furnaces to get as much as possible efficient control of adsorption capacity. In the proposed method it can be seen the correlation between qualitatively-quantitatively composition of the process tail gasses in the production of oil-furnace carbon black and relationship between air for combustion and hydrocarbon feedstock. It is shown that the ratio between air for combustion and hydrocarbon oil feedstock is depended of adsorption capacity summarized by iodine adsorption number, regarding to BMCI index of hydrocarbon oil feedstock.The mentioned correlation can be seen through the figures from 1. to 4. From the whole composition of the process tail gasses the best correlation for continuously and automatically control of iodine adsorption number is show the volume fraction of methane. The volume fraction of methane in the

  19. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    Science.gov (United States)

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  20. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  1. Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)

    International Nuclear Information System (INIS)

    Oothoudt, M.; Pillai, C.; Zumbro, M.

    1997-01-01

    Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances

  2. Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.

    Science.gov (United States)

    Makeyev, Oleksandr; Liu, Xiang; Luna-Munguía, Hiram; Rogel-Salazar, Gabriela; Mucio-Ramirez, Samuel; Liu, Yuhong; Sun, Yan L; Kay, Steven M; Besio, Walter G

    2012-07-01

    Epilepsy affects approximately 1% of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We are developing a noninvasive, or minimally invasive, transcranial focal electrical stimulation system through our novel tripolar concentric ring electrodes to control seizures. In this study, we demonstrate feasibility of an automatic seizure control system in rats with pentylenetetrazole-induced seizures through single and multiple stimulations. These stimulations are automatically triggered by a real-time electrographic seizure activity detector based on a disjunctive combination of detections from a cumulative sum algorithm and a generalized likelihood ratio test. An average seizure onset detection accuracy of 76.14% was obtained for the test set (n = 13). Detection of electrographic seizure activity was accomplished in advance of the early behavioral seizure activity in 76.92% of the cases. Automatically triggered stimulation significantly (p = 0.001) reduced the electrographic seizure activity power in the once stimulated group compared to controls in 70% of the cases. To the best of our knowledge this is the first closed-loop automatic seizure control system based on noninvasive electrical brain stimulation using tripolar concentric ring electrode electrographic seizure activity as feedback.

  3. Changes in automatic threat processing precede and predict clinical changes with exposure-based cognitive-behavior therapy for panic disorder.

    Science.gov (United States)

    Reinecke, Andrea; Waldenmaier, Lara; Cooper, Myra J; Harmer, Catherine J

    2013-06-01

    Cognitive behavioral therapy (CBT) is an effective treatment for emotional disorders such as anxiety or depression, but the mechanisms underlying successful intervention are far from understood. Although it has been a long-held view that psychopharmacological approaches work by directly targeting automatic emotional information processing in the brain, it is usually postulated that psychological treatments affect these processes only over time, through changes in more conscious thought cycles. This study explored the role of early changes in emotional information processing in CBT action. Twenty-eight untreated patients with panic disorder were randomized to a single session of exposure-based CBT or waiting group. Emotional information processing was measured on the day after intervention with an attentional visual probe task, and clinical symptoms were assessed on the day after intervention and at 4-week follow-up. Vigilance for threat information was decreased in the treated group, compared with the waiting group, the day after intervention, before reductions in clinical symptoms. The magnitude of this early effect on threat vigilance predicted therapeutic response after 4 weeks. Cognitive behavioral therapy rapidly affects automatic processing, and these early effects are predictive of later therapeutic change. Such results suggest very fast action on automatic processes mediating threat sensitivity, and they provide an early marker of treatment response. Furthermore, these findings challenge the notion that psychological treatments work directly on conscious thought processes before automatic information processing and imply a greater similarity between early effects of pharmacological and psychological treatments for anxiety than previously thought. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  4. An approach of optimal sensitivity applied in the tertiary loop of the automatic generation control

    Energy Technology Data Exchange (ETDEWEB)

    Belati, Edmarcio A. [CIMATEC - SENAI, Salvador, BA (Brazil); Alves, Dilson A. [Electrical Engineering Department, FEIS, UNESP - Sao Paulo State University (Brazil); da Costa, Geraldo R.M. [Electrical Engineering Department, EESC, USP - Sao Paulo University (Brazil)

    2008-09-15

    This paper proposes an approach of optimal sensitivity applied in the tertiary loop of the automatic generation control. The approach is based on the theorem of non-linear perturbation. From an optimal operation point obtained by an optimal power flow a new optimal operation point is directly determined after a perturbation, i.e., without the necessity of an iterative process. This new optimal operation point satisfies the constraints of the problem for small perturbation in the loads. The participation factors and the voltage set point of the automatic voltage regulators (AVR) of the generators are determined by the technique of optimal sensitivity, considering the effects of the active power losses minimization and the network constraints. The participation factors and voltage set point of the generators are supplied directly to a computational program of dynamic simulation of the automatic generation control, named by power sensitivity mode. Test results are presented to show the good performance of this approach. (author)

  5. Mathematical modelling and quality indices optimization of automatic control systems of reactor facility

    International Nuclear Information System (INIS)

    Severin, V.P.

    2007-01-01

    The mathematical modeling of automatic control systems of reactor facility WWER-1000 with various regulator types is considered. The linear and nonlinear models of neutron power control systems of nuclear reactor WWER-1000 with various group numbers of delayed neutrons are designed. The results of optimization of direct quality indexes of neutron power control systems of nuclear reactor WWER-1000 are designed. The identification and optimization of level control systems with various regulator types of steam generator are executed

  6. Presenting automatic demand control (ADC) as a new frequency control method in smart grids

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Mohammad Taghi; Ameli, Ali; Maleki, Hamed [Power and Water Univ. of Technology, Tehran (Iran, Islamic Republic of); Mobarhani, Alireza [Amir Kabir Univ. of Technology, Tehran (Iran, Islamic Republic of)

    2011-07-01

    Electric power is the most important part of human energy consumption, and since it has a low storage coefficient it is of particular importance to establish a balance in demand and generation in order to modify and optimize consumption patterns. The expression ''Smart Grid'' can be used to describe technologies which are applied for the automation and optimization of the generation, transmission and distribution network management. This technology requires the integration of information and communication technology in electrical network operation. This paper will study how the Smart Grid capabilites can be used to manage and optimize power network consumption, as well as how the consumers collaboration process using an AGC (Automatic Generation Control) system acts to provide secondary frequency control through consumed load shedding. Reestablishing the balance between demand and generation in critical network operation is also investigated. In other words, utilizing the above method, a new system, ADC (Automatic Demand Control), is offered for use alongside the AGC system in Smart Grids to restore the frequency value to its nominal value. This can lead to a more competitive electricity market and reduce the system storage while maintaining adequate security and network reliability. One of the benefits of the proposed methods described in this paper, in addition to restoring the frequency value to its nominal value, is lower costs and a more economic network operation through reducing fuel and CO2 emission by managing and controlling the amount of the consumed load in the Smart Grid. Also consumers are given the capability to have a specific timetable to economize on their energy requirements which will also reduce the load peak and the network losses. (orig.)

  7. Control characteristics and heating performance analysis of automatic thermostatic valves for radiant slab heating system in residential apartments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byung-Cheon [Department of Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea); Song, Jae-Yeob [Graduate School, Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea)

    2010-04-15

    Computer simulations and experiments are carried out to research the control characteristics and heating performances for a radiant slab heating system with automatic thermostatic valves in residential apartments. An electrical equivalent R-C circuit is applied to analyze the unsteady heat transfer in the house. In addition, the radiant heat transfer between slabs, ceilings and walls in the room is evaluated by enclosure analysis method. Results of heating performance and control characteristics were determined from control methods such as automatic thermostatic valves, room air temperature-sensing method, water-temperature-sensing method, proportional control method, and On-Off control method. (author)

  8. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  9. Automatic cryogenic liquid level controller is safe for use near combustible substances

    Science.gov (United States)

    Krejsa, M.

    1966-01-01

    Automatic mechanical liquid level controller that is independent of any external power sources is used with safety in the presence of combustibles. A gas filled capillary tube which leads from a pressurized chamber, is inserted into the cryogenic liquid reservoir and becomes a liquid level sensing element or probe.

  10. Microcomputer-based systems for automatic control of sample irradiation and chemical analysis of short-lived isotopes

    International Nuclear Information System (INIS)

    Bourret, S.C.

    1974-01-01

    Two systems resulted from the need for the study of the nuclear decay of short-lived radionuclides. Automation was required for better repeatability, speed of chemical separation after irradiation and for protection from the high radiation fields of the samples. A MCS-8 computer was used as the nucleus of the automatic sample irradiation system because the control system required an extensive multiple-sequential circuit. This approach reduced the sequential problem to a computer program. The automatic chemistry control system is a mixture of a fixed and a computer-based programmable control system. The fixed control receives the irradiated liquid sample from the reactor, extracts the liquid and disposes of the used sample container. The programmable control executes the chemistry program that the user has entered through the teletype. (U.S.)

  11. Embedded Processor Based Automatic Temperature Control of VLSI Chips

    Directory of Open Access Journals (Sweden)

    Narasimha Murthy Yayavaram

    2009-01-01

    Full Text Available This paper presents embedded processor based automatic temperature control of VLSI chips, using temperature sensor LM35 and ARM processor LPC2378. Due to the very high packing density, VLSI chips get heated very soon and if not cooled properly, the performance is very much affected. In the present work, the sensor which is kept very near proximity to the IC will sense the temperature and the speed of the fan arranged near to the IC is controlled based on the PWM signal generated by the ARM processor. A buzzer is also provided with the hardware, to indicate either the failure of the fan or overheating of the IC. The entire process is achieved by developing a suitable embedded C program.

  12. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  13. Solution Approach to Automatic Generation Control Problem Using Hybridized Gravitational Search Algorithm Optimized PID and FOPID Controllers

    Directory of Open Access Journals (Sweden)

    DAHIYA, P.

    2015-05-01

    Full Text Available This paper presents the application of hybrid opposition based disruption operator in gravitational search algorithm (DOGSA to solve automatic generation control (AGC problem of four area hydro-thermal-gas interconnected power system. The proposed DOGSA approach combines the advantages of opposition based learning which enhances the speed of convergence and disruption operator which has the ability to further explore and exploit the search space of standard gravitational search algorithm (GSA. The addition of these two concepts to GSA increases its flexibility for solving the complex optimization problems. This paper addresses the design and performance analysis of DOGSA based proportional integral derivative (PID and fractional order proportional integral derivative (FOPID controllers for automatic generation control problem. The proposed approaches are demonstrated by comparing the results with the standard GSA, opposition learning based GSA (OGSA and disruption based GSA (DGSA. The sensitivity analysis is also carried out to study the robustness of DOGSA tuned controllers in order to accommodate variations in operating load conditions, tie-line synchronizing coefficient, time constants of governor and turbine. Further, the approaches are extended to a more realistic power system model by considering the physical constraints such as thermal turbine generation rate constraint, speed governor dead band and time delay.

  14. Automatic generation of configuration files for a distributed control system

    CERN Document Server

    Cupérus, J

    1995-01-01

    The CERN PS accelerator complex is composed of 9 interlinked accelerators for production and acceleration of various kinds of particles. The hardware is controlled through CAMAC, VME, G64, and GPIB modules, which in turn are controlled by more than 100 microprocessors in VME crates. To produce startup files for all these microprocessors, with the correct drivers, programs and parameters in each of them, is quite a challenge. The problem is solved by generating the startup files automatically from the description of the control system in a relational database. The generation process detects inconsistencies and incomplete information. Included in the startup files are data which are formally comments, but can be interpreted for run-time checking of interface modules and program activity.

  15. Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography

    International Nuclear Information System (INIS)

    Kim, Jung-Su; Yoon, Sang-Wook; Seo, Deok-Nam; Nam, So-Ra; Kim, Jung-Min

    2016-01-01

    Whole spine scanography (WSS) is a radiologic examination that requires whole body X-ray exposure. Consequently, the amount of patient radiation exposure is higher than the radiation dose following routine X-ray examination. Several studies have evaluated the patient effective dose (ED) following single exposure film-screen WSS. The objective of this study was to evaluate patient ED during WSS, based on the automatic image pasting method for multiple exposure digital radiography (APMDR). Further, the calculated EDs were compared with the results of previous studies involving single exposure film-screen WSS. We evaluated the ED of 50 consecutive patients (M:F = 28:22) who underwent WSS using APMDR. The anterior-posterior (AP) and lateral (LAT) projection EDs were evaluated based on the Monte Carlo simulation. Using APMDR, the mean number of exposures was 6.1 for AP and 6.5 for LAT projections. LAT projections required more exposures (6.55%) than AP projections. The mean ED was 0.6276 mSv (AP) and 0.6716 mSv (LAT). The mean ED for LAT projections was 0.6061 mSv in automatic exposure control (AEC) and 0.7694 mSv in manual mode. The relationship between dose-area-product (DAP) and ED revealed a proportional correlation (AP, R 2 = 0.943; LAT, R 2 = 0.773). Compared to prior research involving single exposure screen-film WSS, the patient ED following WSS using APMDR was lower on AP than on LAT projections. Despite multiple exposures, ED control is more effective if WSS is performed using APMDR in the AEC mode

  16. Microcontroller based automatic liquid poison addition control system

    International Nuclear Information System (INIS)

    Kapatral, R.S.; Ananthakrishnan, T.S.; Pansare, M.G.

    1989-01-01

    Microcontrollers are finding increasing applications in instrumentation where complex digital circuits can be substituted by a compact and simple circuit, thus enhancing the reliability. In addition to this, intelligence and flexibility can be incorporated. For applications not requiring large amount of read/write memory (RAM), microcontrollers are ideally suited since they contain programmable memory (Eprom), parallel input/output lines, data memory, programmable timers and serial interface ports in one chip. This paper describes the design of automatic liquid poison addition control system (ALPAS) using intel's 8 bit microcontroller 8751, which is used to generate complex timing control sequence signals for liquid poison addition to the moderator in a nuclear reactor. ALPAS monitors digital inputs coming from protection system and regulating system of a nuclear reactor and provides control signals for liquid poison addition for long term safe shutdown of the reactor after reactor trip and helps the regulating system to reduce the power of the reactor during operation. Special hardware and software features have been incorporated to improve performance and fault detection. (author)

  17. The Development of Automatic and Controlled Inhibitory Retrieval Processes in True and False Recall

    Science.gov (United States)

    Knott, Lauren M.; Howe, Mark L.; Wimmer, Marina C.; Dewhurst, Stephen A.

    2011-01-01

    In three experiments, we investigated the role of automatic and controlled inhibitory retrieval processes in true and false memory development in children and adults. Experiment 1 incorporated a directed forgetting task to examine controlled retrieval inhibition. Experiments 2 and 3 used a part-set cue and retrieval practice task to examine…

  18. Design of automatic control system of temperature in radon chamber controlled by air-condition based on 485 BUS

    International Nuclear Information System (INIS)

    Man Zaigang; Wang Renbo; Zhang Xiongjie; Zhu Zhifu; Tang Bin

    2009-01-01

    Radon chamber can be widely used in various radon measurement instruments for calibration, testing and radon environment experiment. According to requisition, radon chamber temperature should be controllable from +10 degree C to +30 degree C, and the temperature control accuracy of the system reaches ±1 degree C. The design of automatic temperature controlled by air-condition based on 485 BUS is introduced. The software and hardware techniques of how the ATMEL89S52 micro controller controls air-condition and communicates with computer are elaborated on. (authors)

  19. Automatic gain control of neural coupling during cooperative hand movements.

    Science.gov (United States)

    Thomas, F A; Dietz, V; Schrafl-Altermatt, M

    2018-04-13

    Cooperative hand movements (e.g. opening a bottle) are controlled by a task-specific neural coupling, reflected in EMG reflex responses contralateral to the stimulation site. In this study the contralateral reflex responses in forearm extensor muscles to ipsilateral ulnar nerve stimulation was analyzed at various resistance and velocities of cooperative hand movements. The size of contralateral reflex responses was closely related to the level of forearm muscle activation required to accomplish the various cooperative hand movement tasks. This indicates an automatic gain control of neural coupling that allows a rapid matching of corrective forces exerted at both sides of an object with the goal 'two hands one action'.

  20. Development of advanced automatic operation system for nuclear ship. 1. Perfect automatic normal operation

    International Nuclear Information System (INIS)

    Nakazawa, Toshio; Yabuuti, Noriaki; Takahashi, Hiroki; Shimazaki, Junya

    1999-02-01

    Development of operation support system such as automatic operating system and anomaly diagnosis systems of nuclear reactor is very important in practical nuclear ship because of a limited number of operators and severe conditions in which receiving support from others in a case of accident is very difficult. The goal of development of the operation support systems is to realize the perfect automatic control system in a series of normal operation from the reactor start-up to the shutdown. The automatic control system for the normal operation has been developed based on operating experiences of the first Japanese nuclear ship 'Mutsu'. Automation technique was verified by 'Mutsu' plant data at manual operation. Fully automatic control of start-up and shutdown operations was achieved by setting the desired value of operation and the limiting value of parameter fluctuation, and by making the operation program of the principal equipment such as the main coolant pump and the heaters. This report presents the automatic operation system developed for the start-up and the shutdown of reactor and the verification of the system using the Nuclear Ship Engineering Simulator System. (author)

  1. Study and development of techniques for automatic control of remote manipulators

    Science.gov (United States)

    Shaket, E.; Leal, A.

    1976-01-01

    An overall conceptual design for an autonomous control system of remote manipulators which utilizes feedback was constructed. The system consists of a description of the high-level capabilities of a model from which design algorithms are constructed. The autonomous capability is achieved through automatic planning and locally controlled execution of the plans. The operator gives his commands in high level task-oriented terms. The system transforms these commands into a plan. It uses built-in procedural knowledge of the problem domain and an internal model of the current state of the world.

  2. Improving the safety and protective automatic actions of the CMS electromagnetic calorimeter detector control system

    CERN Document Server

    Jimenez Estupinan, Raul; Cirkovic, Predrag; Di Calafiori, Diogo Raphael; Dissertori, Guenther; Djambazov, Lubomir; Jovanovic, Dragoslav; Lustermann, Werner; Milenovic, Predrag; Zelepoukine, Serguei

    2017-01-01

    The CMS ECAL Detector Control System (DCS) features several monitoring mechanisms able to react and perform automatic actions based on pre-defined action matrices. The DCS is capable of early detection of anomalies inside the ECAL and on its off-detector support systems, triggering automatic actions to mitigate the impact of these events and preventing them from escalating to the safety system. The treatment of such events by the DCS allows for a faster recovery process, better understanding of the development of issues, and in most cases, actions with higher granularity than the safety system. This paper presents the details of the DCS automatic action mechanisms, as well as their evolution based on several years of CMS ECAL operations.

  3. Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion 71110, Crete (Greece)

    2008-10-15

    The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i

  4. Developmental Dyscalculia and Automatic Magnitudes Processing: Investigating Interference Effects between Area and Perimeter

    Directory of Open Access Journals (Sweden)

    Hili Eidlin-Levy

    2017-12-01

    Full Text Available The relationship between numbers and other magnitudes has been extensively investigated in the scientific literature. Here, the objectives were to examine whether two continuous magnitudes, area and perimeter, are automatically processed and whether adults with developmental dyscalculia (DD are deficient in their ability to automatically process one or both of these magnitudes. Fifty-seven students (30 with DD and 27 with typical development performed a novel Stroop-like task requiring estimation of one aspect (area or perimeter while ignoring the other. In order to track possible changes in automaticity due to practice, we measured performance after initial and continuous exposure to stimuli. Similar to previous findings, current results show a significant group × congruency interaction, evident beyond exposure level or magnitude type. That is, the DD group systematically showed larger Stroop effects. However, analysis of each exposure period showed that during initial exposure to stimuli the DD group showed larger Stroop effects in the perimeter and not in the area task. In contrast, during continuous exposure to stimuli no triple interaction was evident. It is concluded that both magnitudes are automatically processed. Nevertheless, individuals with DD are deficient in inhibiting irrelevant magnitude information in general and, specifically, struggle to inhibit salient area information after initial exposure to a perimeter comparison task. Accordingly, the findings support the assumption that DD involves a deficiency in multiple cognitive components, which include domain-specific and domain-general cognitive functions.

  5. Developmental Dyscalculia and Automatic Magnitudes Processing: Investigating Interference Effects between Area and Perimeter.

    Science.gov (United States)

    Eidlin-Levy, Hili; Rubinsten, Orly

    2017-01-01

    The relationship between numbers and other magnitudes has been extensively investigated in the scientific literature. Here, the objectives were to examine whether two continuous magnitudes, area and perimeter, are automatically processed and whether adults with developmental dyscalculia (DD) are deficient in their ability to automatically process one or both of these magnitudes. Fifty-seven students (30 with DD and 27 with typical development) performed a novel Stroop-like task requiring estimation of one aspect (area or perimeter) while ignoring the other. In order to track possible changes in automaticity due to practice, we measured performance after initial and continuous exposure to stimuli. Similar to previous findings, current results show a significant group × congruency interaction, evident beyond exposure level or magnitude type. That is, the DD group systematically showed larger Stroop effects. However, analysis of each exposure period showed that during initial exposure to stimuli the DD group showed larger Stroop effects in the perimeter and not in the area task. In contrast, during continuous exposure to stimuli no triple interaction was evident. It is concluded that both magnitudes are automatically processed. Nevertheless, individuals with DD are deficient in inhibiting irrelevant magnitude information in general and, specifically, struggle to inhibit salient area information after initial exposure to a perimeter comparison task. Accordingly, the findings support the assumption that DD involves a deficiency in multiple cognitive components, which include domain-specific and domain-general cognitive functions.

  6. Electronic control of a 4-speed automatic transmission with lock-up clutch

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, M.

    1984-01-01

    The paper describes the electronic control of an automatic 4-speed transmission with lock-up clutch. As compared to purely hydraulically controlled transmissions, this control offers a clearly improved quality of shifting and the possibility of achieving improvements in fuel consumption thanks to a special economy program. The electronic control unit is a Bosch MOTRONIC which has been expanded to include the functions of transmission control. A special feature is the engine torque control which is implemented by way of retarding the ignition when shifting. This opens up an additional degree of freedom for optimizing a transmission in terms of shift comfort, life of the friction elements and the power which can be transmitted.

  7. Adaptive automatic generation control with superconducting magnetic energy storage in power systems

    International Nuclear Information System (INIS)

    Tripathy, S.C.; Balasubramanian, R.; Nair, P.S.C.

    1992-01-01

    An improved automatic generation control (AGC) employing self-tuning adaptive control for both main AGC loop and superconducting magnetic energy storage (SMES) is presented in this paper. Computer simulations on a two-area interconnected power system show that the proposed adaptive control scheme is very effective in damping out oscillations caused by load disturbances and its performance is quite insensitive to controller gain parameter changes of SMES. A comprehensive comparative performance evaluation of control schemes using adaptive and non-adaptive controllers in the main AGC and in the SMES control loops is presented. The improvement in performance brought in by the adaptive scheme is particularly pronounced for load changes of random magnitude and duration. The proposed controller can be easily implemented using microprocessors

  8. The control of automatic imitation based on bottom-up and top-down cues to animacy: insights from brain and behavior.

    Science.gov (United States)

    Klapper, André; Ramsey, Richard; Wigboldus, Daniël; Cross, Emily S

    2014-11-01

    Humans automatically imitate other people's actions during social interactions, building rapport and social closeness in the process. Although the behavioral consequences and neural correlates of imitation have been studied extensively, little is known about the neural mechanisms that control imitative tendencies. For example, the degree to which an agent is perceived as human-like influences automatic imitation, but it is not known how perception of animacy influences brain circuits that control imitation. In the current fMRI study, we examined how the perception and belief of animacy influence the control of automatic imitation. Using an imitation-inhibition paradigm that involves suppressing the tendency to imitate an observed action, we manipulated both bottom-up (visual input) and top-down (belief) cues to animacy. Results show divergent patterns of behavioral and neural responses. Behavioral analyses show that automatic imitation is equivalent when one or both cues to animacy are present but reduces when both are absent. By contrast, right TPJ showed sensitivity to the presence of both animacy cues. Thus, we demonstrate that right TPJ is biologically tuned to control imitative tendencies when the observed agent both looks like and is believed to be human. The results suggest that right TPJ may be involved in a specialized capacity to control automatic imitation of human agents, rather than a universal process of conflict management, which would be more consistent with generalist theories of imitative control. Evidence for specialized neural circuitry that "controls" imitation offers new insight into developmental disorders that involve atypical processing of social information, such as autism spectrum disorders.

  9. Automatic/Control Processing Concepts and Their Implications for the Training of Skills.

    Science.gov (United States)

    1982-04-01

    driving a car are examples of automatic processes. Controll p s is comparatively slow, serial, limited by short-term memory, and requires subject effort...development has convinced us that moivation a oftn more Jmportn nti mAn =other iJli velLJoa jjthpgy gI. njj Lautomatic U_2,LLjjk. Motivation Is much more

  10. An automatic control of the pumping system for the vacuum chamber of the cyclotron

    International Nuclear Information System (INIS)

    Ikegami, Kumio; Kageyama, Tadashi; Kohno, Isao

    1979-01-01

    The main pumping system of the 160 cm cyclotron is composed of 32'', 14'', and 6'' oil difusion pumps connected in series and rough pumping system which consists of 1500 l/min rotary pump and 300 m 3 /h roots pump with 650 l/min rotary backing pump. Instead of manual operation an automatic control devise of the pumping system was developed and many valves were replaced with pneumatic ones. In the new control system, pumps and valves are operated automatically, according to the indication of pirani detectors, to evacuate the chamber of the cyclotron up to the pressure of 0.7 - 1.0 x 10 -6 Torr, and also to protect the pumping system against vacuum failure by accidental leakage in the chamber. The graphic handling board of the pumping system is installed on the control panel and each switch is provided with a name card showing its function briefly. (author)

  11. Automatic Control of Contextual Interaction Integrated with Affection and Architectural Attentional Control

    Directory of Open Access Journals (Sweden)

    Yanrong Jiang

    2013-03-01

    Full Text Available It is still a challenge for robots to interact with complex environments in a smooth and natural manner. The robot should be aware of its surroundings and inner status to make decisions accordingly and appropriately. Contexts benefit the interaction a lot, such as avoiding frequent interruptions (e.g., the explicit inputting requests and thus are essential for interaction. Other challenges, such as shifting attentional focus to a more important stimulus, etc., are also crucial in interaction control. This paper presents a hybrid automatic control approach for interaction, as well as its integration, with these multiple important factors, aiming at performing natural, human-like interactions in robots. In particular, a novel approach of architectural attentional control, based on affection is presented, which attempts to shift the attentional focus in a natural manner. Context-aware computing is combined with interaction to endow the robot with proactive abilities. The long-term interaction control approaches are described. Emotion and personality are introduced into the interaction and their influence mechanism on interaction is explored. We implemented the proposal in an interactive head robot (IHR and the experimental results indicate the effectiveness.

  12. Automaticity of walking: functional significance, mechanisms, measurement and rehabilitation strategies

    Directory of Open Access Journals (Sweden)

    David J Clark

    2015-05-01

    Full Text Available Automaticity is a hallmark feature of walking in adults who are healthy and well-functioning. In the context of walking, ‘automaticity’ refers to the ability of the nervous system to successfully control typical steady state walking with minimal use of attention-demanding executive control resources. Converging lines of evidence indicate that walking deficits and disorders are characterized in part by a shift in the locomotor control strategy from healthy automaticity to compensatory executive control. This is potentially detrimental to walking performance, as an executive control strategy is not optimized for locomotor control. Furthermore, it places excessive demands on a limited pool of executive reserves. The result is compromised ability to perform basic and complex walking tasks and heightened risk for adverse mobility outcomes including falls. Strategies for rehabilitation of automaticity are not well defined, which is due to both a lack of systematic research into the causes of impaired automaticity and to a lack of robust neurophysiological assessments by which to gauge automaticity. These gaps in knowledge are concerning given the serious functional implications of compromised automaticity. Therefore, the objective of this article is to advance the science of automaticity of walking by consolidating evidence and identifying gaps in knowledge regarding: a functional significance of automaticity; b neurophysiology of automaticity; c measurement of automaticity; d mechanistic factors that compromise automaticity; and e strategies for rehabilitation of automaticity.

  13. GSM Web-Based Centralized Remote Wireless Automatic Controlling and Monitoring of Aquafeeder

    Science.gov (United States)

    Wong, C. L.; Idris, A.; Hasan, Z.

    2016-03-01

    This project is about producing a prototype to feed fishes at fish ponds of remote location with the use of GSM mobile phone. An automatic fish feeder is an electric device that has been designed to give out the right amount of pellets at the designed time. In this project, the automatic feeder designed consists of photovoltaic solar cells that are used to generate electricity and storing it into batteries. Solar charge controllers can be used to determine the rate of which current is drawn and added from the batteries. GSM cellular communication is used to allow user to control from a distance. Commands or instructions are sent to the operating system which in return runs the servomotor and blower by blowing certain amount of fish pallets into the pond to feed the fishes. The duration of the feeding processes is fixed by the user, hence the amount of fish food pallets released are precisely the same for each time. This technology is especially useful for fish farmers where they can remotely feed their fishes.

  14. Automatic control system in the reactor peggy

    International Nuclear Information System (INIS)

    Bertrand, J.; Mourchon, R.; Da Costa, D.; Desandre-Navarre, Ch.

    1967-01-01

    The equipment makes it possible for the reactor to attain a given power automatically and for the power to be maintained around this level. The principle of its operation consists in the changing from one power to another, at constant period, by means of a programmer transforming a power-step request into a voltage variation which is linear with time and which represents the logarithm of the required power. The real power is compared continuously with the required power. Stabilization occurs automatically as soon as the difference between the reactor power and the required power diminishes to a few per cent. (authors) [fr

  15. Knowledge-based full-automatic control system for a nuclear ship reactor

    International Nuclear Information System (INIS)

    Shimazaki, J.; Nakazawa, T.; Yabuuchi, N.

    2000-01-01

    Plant operations aboard nuclear ships require quick judgements and actions due to changing marine conditions such as wind, waves and currents. Furthermore, additional human support is not available for nuclear ship operation at sea, so advanced automatic operations are necessary to reduce the number of operators required finally. Therefore, an advanced automatic operating system has been developed based on operational knowledge of nuclear ship 'Mutsu' plant. The advanced automatic operating system includes both the automatic operation system and the operator-support system which assists operators in completing actions during plant accidents, anomaly diagnosis and plant supervision. These system are largely being developed using artificial intelligent techniques such as neural network, fuzzy logic and knowledge-based expert. The automatic operation system is fundamentally based upon application of an operator's knowledge of both normal (start-up to rated power level) and abnormal (after scram) operations. Comparing plant behaviors from start-up to power level by the automatic operation with by 'Mutsu' manual operation, stable automatic operation was obtained almost same as manual operation within all operating limits. The abnormal automatic system was for hard work of manual operations after scram or LOCA accidents. An integrating system with the normal and the abnormal automatic systems are being developed for interacting smoothly both systems. (author)

  16. An electronically controlled automatic security access gate

    Directory of Open Access Journals (Sweden)

    Jonathan A. ENOKELA

    2014-11-01

    Full Text Available The security challenges being encountered in many places require electronic means of controlling access to communities, recreational centres, offices, and homes. The electronically controlled automated security access gate being proposed in this work helps to prevent an unwanted access to controlled environments. This is achieved mainly through the use of a Radio Frequency (RF transmitter-receiver pair. In the design a microcontroller is programmed to decode a given sequence of keys that is entered on a keypad and commands a transmitter module to send out this code as signal at a given radio frequency. Upon reception of this RF signal by the receiver module, another microcontroller activates a driver circuitry to operate the gate automatically. The codes for the microcontrollers were written in C language and were debugged and compiled using the KEIL Micro vision 4 integrated development environment. The resultant Hex files were programmed into the memories of the microcontrollers with the aid of a universal programmer. Software simulation was carried out using the Proteus Virtual System Modeling (VSM version 7.7. A scaled-down prototype of the system was built and tested. The electronically controlled automated security access gate can be useful in providing security for homes, organizations, and automobile terminals. The four-character password required to operate the gate gives the system an increased level of security. Due to its standalone nature of operation the system is cheaper to maintain in comparison with a manually operated type.

  17. Automatic analysis of image quality control for Image Guided Radiation Therapy (IGRT) devices in external radiotherapy

    International Nuclear Information System (INIS)

    Torfeh, Tarraf

    2009-01-01

    On-board imagers mounted on a radiotherapy treatment machine are very effective devices that improve the geometric accuracy of radiation delivery. However, a precise and regular quality control program is required in order to achieve this objective. Our purpose consisted of developing software tools dedicated to an automatic image quality control of IGRT devices used in external radiotherapy: 2D-MV mode for measuring patient position during the treatment using high energy images, 2D-kV mode (low energy images) and 3D Cone Beam Computed Tomography (CBCT) MV or kV mode, used for patient positioning before treatment. Automated analysis of the Winston and Lutz test was also proposed. This test is used for the evaluation of the mechanical aspects of treatment machines on which additional constraints are carried out due to the on-board imagers additional weights. Finally, a technique of generating digital phantoms in order to assess the performance of the proposed software tools is described. Software tools dedicated to an automatic quality control of IGRT devices allow reducing by a factor of 100 the time spent by the medical physics team to analyze the results of controls while improving their accuracy by using objective and reproducible analysis and offering traceability through generating automatic monitoring reports and statistical studies. (author) [fr

  18. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  19. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    Science.gov (United States)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  20. Decentralized automatic generation control of interconnected power systems incorporating asynchronous tie-lines.

    Science.gov (United States)

    Ibraheem; Hasan, Naimul; Hussein, Arkan Ahmed

    2014-01-01

    This Paper presents the design of decentralized automatic generation controller for an interconnected power system using PID, Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The designed controllers are tested on identical two-area interconnected power systems consisting of thermal power plants. The area interconnections between two areas are considered as (i) AC tie-line only (ii) Asynchronous tie-line. The dynamic response analysis is carried out for 1% load perturbation. The performance of the intelligent controllers based on GA and PSO has been compared with the conventional PID controller. The investigations of the system dynamic responses reveal that PSO has the better dynamic response result as compared with PID and GA controller for both type of area interconnection.

  1. Automatic and controlled attentional orienting in the elderly: A dual-process view of the positivity effect.

    Science.gov (United States)

    Gronchi, G; Righi, S; Pierguidi, L; Giovannelli, F; Murasecco, I; Viggiano, M P

    2018-04-01

    The positivity effect in the elderly consists of an attentional preference for positive information as well as avoidance of negative information. Extant theories predict either that the positivity effect depends on controlled attentional processes (socio-emotional selectivity theory), or on an automatic gating selection mechanism (dynamic integration theory). This study examined the role of automatic and controlled attention in the positivity effect. Two dot-probe tasks (with the duration of the stimuli lasting 100 ms and 500 ms, respectively) were employed to compare the attentional bias of 35 elderly people to that of 35 young adults. The stimuli used were expressive faces displaying neutral, disgusted, fearful, and happy expressions. In comparison to young people, the elderly allocated more attention to happy faces at 100 ms and they tended to avoid fearful faces at 500 ms. The findings are not predicted by either theory taken alone, but support the hypothesis that the positivity effect in the elderly is driven by two different processes: an automatic attention bias toward positive stimuli, and a controlled mechanism that diverts attention away from negative stimuli. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. No effects of a single 3G UMTS mobile phone exposure on spontaneous EEG activity, ERP correlates, and automatic deviance detection.

    Science.gov (United States)

    Trunk, Attila; Stefanics, Gábor; Zentai, Norbert; Kovács-Bálint, Zsófia; Thuróczy, György; Hernádi, István

    2013-01-01

    Potential effects of a 30 min exposure to third generation (3G) Universal Mobile Telecommunications System (UMTS) mobile phone-like electromagnetic fields (EMFs) were investigated on human brain electrical activity in two experiments. In the first experiment, spontaneous electroencephalography (sEEG) was analyzed (n = 17); in the second experiment, auditory event-related potentials (ERPs) and automatic deviance detection processes reflected by mismatch negativity (MMN) were investigated in a passive oddball paradigm (n = 26). Both sEEG and ERP experiments followed a double-blind protocol where subjects were exposed to either genuine or sham irradiation in two separate sessions. In both experiments, electroencephalograms (EEG) were recorded at midline electrode sites before and after exposure while subjects were watching a silent documentary. Spectral power of sEEG data was analyzed in the delta, theta, alpha, and beta frequency bands. In the ERP experiment, subjects were presented with a random series of standard (90%) and frequency-deviant (10%) tones in a passive binaural oddball paradigm. The amplitude and latency of the P50, N100, P200, MMN, and P3a components were analyzed. We found no measurable effects of a 30 min 3G mobile phone irradiation on the EEG spectral power in any frequency band studied. Also, we found no significant effects of EMF irradiation on the amplitude and latency of any of the ERP components. In summary, the present results do not support the notion that a 30 min unilateral 3G EMF exposure interferes with human sEEG activity, auditory evoked potentials or automatic deviance detection indexed by MMN. Copyright © 2012 Wiley Periodicals, Inc.

  3. Development of Automatic Control of Bayer Plant Digestion

    Science.gov (United States)

    Riffaud, J. P.

    Supervisory computer control has been achieved in Alcan's Bayer Plants at Arvida, Quebec, Canada. The purpose of the automatic control system is to stabilize and consequently increase, the alumina/caustic ratio within the digester train and in the blow-off liquor. Measurements of the electrical conductivity of the liquor are obtained from electrodeless conductivity meters. These signals, along with several others are scanned by the computer and converted to engineering units, using specific relationships which are updated periodically for calibration purposes. On regular time intervals, values of ratio are compared to target values and adjustments are made to the bauxite flow entering the digesters. Dead time compensation included in the control algorithm enables a faster rate for corrections. Modification of production rate is achieved through careful timing of various flow changes. Calibration of the conductivity meters is achieved by sampling at intervals the liquor flowing through them, and analysing it with a thermometric titrator. Calibration of the thermometric titrator is done at intervals with a standard solution. Calculations for both calibrations are performed by computer from data entered by the analyst. The computer was used for on-line data collection, modelling of the digester system, calculation of disturbances and simulation of control strategies before implementing the most successful strategy in the Plant. Control of ratio has been improved by the integrated system, resulting in increased Plant productivity.

  4. Control of external radiation exposure

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Control of external radiation exposure: working time, working distance, shielding: Total Linear Attenuation Coefficient, Half-Value Layer (HVL), Tenth-Value Layer (TVL); Build-up Factor

  5. Automatic exposure system for radioactive source at teaching laboratory; Sistema automatico de abertura de fonte radioativa em laboratorio de ensino

    Energy Technology Data Exchange (ETDEWEB)

    Seren, Maria Emilia G.; Gaal, Vladmir; Morais, Sergio Luiz de; Rodrigues, Varlei, E-mail: mseren@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin

    2013-12-15

    The development of Compton Scattering experiment, studied by undergraduate students of the Medical Physics course at the Universidade Estadual de Campinas (UNICAMP), takes place in the Medical Physics Teaching Laboratory, belonging to the Gleb Wataghin Physics Institute (IFGW/UNICAMP). The experiment consists of a fixed {sup 137}Cs radioactive source, with current activity of 610.5 MBq and a scintillation detector that turns around the center of the system whose function is to detect the scattered photons spectrum by a scatter object (target). The {sup 137}Cs source is stored in a lead shield with a collimating window for the gamma radiation emitted with energy of 0.662 MeV. This source is exposed only when an attenuation barrier protecting the collimating window is opened. The process of opening and closing the attenuation barrier may deliver a radiation dose to users when done manually. Considering the stochastic harmful effects of ionizing radiation, the goal of this project was to develop an automatic exposure system of the radioactive source, in order to reduce the radiation dose received during the Compton Scattering experiment. The developed system is micro controlled and performs standard operating routines, responding to emergencies. Furthermore, an electromagnetic lock enables quick closing of the barrier by gravity, in case of interruption of the electrical current circuit. Besides reducing the total dose to lab users, the system adds more security to the routine, since it limits the access to the radioactive source and prevents accidental exposure. (author)

  6. SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

    Energy Technology Data Exchange (ETDEWEB)

    Park, M; Rosica, D; Agarwal, V; Di Carli, M; Dorbala, S [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984 pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.

  7. 30 CFR 57.5005 - Control of exposure to airborne contaminants.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Underground § 57.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention of contamination, removal by exhaust...

  8. Automatic Scheduling and Planning (ASAP) in future ground control systems

    Science.gov (United States)

    Matlin, Sam

    1988-01-01

    This report describes two complementary approaches to the problem of space mission planning and scheduling. The first is an Expert System or Knowledge-Based System for automatically resolving most of the activity conflicts in a candidate plan. The second is an Interactive Graphics Decision Aid to assist the operator in manually resolving the residual conflicts which are beyond the scope of the Expert System. The two system designs are consistent with future ground control station activity requirements, support activity timing constraints, resource limits and activity priority guidelines.

  9. Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Mervyn D. [Indiana University School of Medicine, Department of Radiology, Riley Children' s Hospital, Indianapolis, IN (United States); Riley Hospital for Children, Department of Radiology, Indianapolis, IN (United States); Cooper, Matt L.; Piersall, Kelly [Indiana University School of Medicine, Department of Radiology, Riley Children' s Hospital, Indianapolis, IN (United States); Apgar, Bruce K. [Agfa HealthCare Corporation, Greenville, SC (United States)

    2011-05-15

    Many methods are used to track patient exposure during acquisition of plain film radiographs. A uniform international standard would aid this process. To evaluate and describe a new, simple quality-assurance method for monitoring patient exposure. This method uses the ''exposure index'' and the ''deviation index,'' recently developed by the International Electrotechnical Commission (IEC) and American Association of Physicists in Medicine (AAPM). The deviation index measures variation from an ideal target exposure index value. Our objective was to determine whether the exposure index and the deviation index can be used to monitor and control exposure drift over time. Our Agfa workstation automatically keeps a record of the exposure index for every patient. The exposure index and deviation index were calculated on 1,884 consecutive neonatal chest images. Exposure of a neonatal chest phantom was performed as a control. Acquisition of the exposure index and calculation of the deviation index was easily achieved. The weekly mean exposure index of the phantom and the patients was stable and showed <10% change during the study, indicating no exposure drift during the study period. The exposure index is an excellent tool to monitor the consistency of patient exposures. It does not indicate the exposure value used, but is an index to track compliance with a pre-determined target exposure. (orig.)

  10. Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates

    International Nuclear Information System (INIS)

    Cohen, Mervyn D.; Cooper, Matt L.; Piersall, Kelly; Apgar, Bruce K.

    2011-01-01

    Many methods are used to track patient exposure during acquisition of plain film radiographs. A uniform international standard would aid this process. To evaluate and describe a new, simple quality-assurance method for monitoring patient exposure. This method uses the ''exposure index'' and the ''deviation index,'' recently developed by the International Electrotechnical Commission (IEC) and American Association of Physicists in Medicine (AAPM). The deviation index measures variation from an ideal target exposure index value. Our objective was to determine whether the exposure index and the deviation index can be used to monitor and control exposure drift over time. Our Agfa workstation automatically keeps a record of the exposure index for every patient. The exposure index and deviation index were calculated on 1,884 consecutive neonatal chest images. Exposure of a neonatal chest phantom was performed as a control. Acquisition of the exposure index and calculation of the deviation index was easily achieved. The weekly mean exposure index of the phantom and the patients was stable and showed <10% change during the study, indicating no exposure drift during the study period. The exposure index is an excellent tool to monitor the consistency of patient exposures. It does not indicate the exposure value used, but is an index to track compliance with a pre-determined target exposure. (orig.)

  11. Automatic generation control with thyristor controlled series compensator including superconducting magnetic energy storage units

    Directory of Open Access Journals (Sweden)

    Saroj Padhan

    2014-09-01

    Full Text Available In the present work, an attempt has been made to understand the dynamic performance of Automatic Generation Control (AGC of multi-area multi-units thermal–thermal power system with the consideration of Reheat turbine, Generation Rate Constraint (GRC and Time delay. Initially, the gains of the fuzzy PID controller are optimized using Differential Evolution (DE algorithm. The superiority of DE is demonstrated by comparing the results with Genetic Algorithm (GA. After that performance of Thyristor Controlled Series Compensator (TCSC has been investigated. Further, a TCSC is placed in the tie-line and Superconducting Magnetic Energy Storage (SMES units are considered in both areas. Finally, sensitivity analysis is performed by varying the system parameters and operating load conditions from their nominal values. It is observed that the optimum gains of the proposed controller need not be reset even if the system is subjected to wide variation in loading condition and system parameters.

  12. Electric Drive Discrete Control System with Automatic Switching-On Reserve for Autonomous Settlement

    Directory of Open Access Journals (Sweden)

    Tsytovich L.I.

    2015-08-01

    Full Text Available The paper aims at developing of control the water supply system’s electric drives for autonomous settlement. The system provides automatic switching to a reserve control channel at refusal of any of the functional elements of the working regulation channel. Usually, such systems have a test signal generator and analyzer to system response to their impact. This result to an increase in the structural redundancy of the system, increase its cost and increase the requirements for the staff qualification. A specific feature of the system is its ability to self-diagnosis of catastrophic malfunctions of scheme’s components and an automatic switching-on the reserve control channels, without applying any test signals to the whole complex of electrical equipment. Multi-zone integrating regulator with frequency-pulse-width modulation realizes this technical solution. Control system structure and signals timing diagrams are presented. The construction principle of adaptive interval-code synchronization device with improved noise stability to control the voltage regulators serving for smooth start-up of asynchronous motors of water pumps is considered as well. Such solution allowing increase noise stability and reliability work of the system in conditions of limited power electrical networks, which is characteristic for the autonomous settlements. The article may be of interest to specialists in the field of power electronics and information electronics, electric drives and process automation.

  13. 30 CFR 56.5005 - Control of exposure to airborne contaminants.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Air Quality and Physical Agents Air Quality § 56.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention...

  14. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    An automatic voltage control (AVC) system maintains the voltage profile of a power system in an acceptable range and minimizes the operational cost by coordinating the regulation of controllable components. Typically, all of the parameters in the optimization problem are assumed to be certain...... and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  15. The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    Karppinen, J.; Parviainen, T.

    1993-03-01

    The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA) in Finland was studied using phantom measurements. Additional tests were made concerning the performance of TV fluoroscopy systems, cine fluorographic units and film processing. These tests include sensitometric quality control of film processing, automatic exposure control in fluoroscopy and cinefluorography, and contrast and resolution in a cine frame and TV image

  16. Low Speed Control for Automatic Welding

    Science.gov (United States)

    Iceland, W. E.

    1982-01-01

    Amplifier module allows rotating positioner of automatic welding machine to operate at speeds below normal range. Low speeds are precisely regulated by a servomechanism as are normal-range speeds. Addition of module to standard welding machine makes it unnecessary to purchase new equipment for low-speed welding.

  17. Theoretical study of an on-off automatic control system for a nuclear reactor

    International Nuclear Information System (INIS)

    Menezes, J.; Jover, P.

    1964-01-01

    The automatic control system designed for a high flux nuclear reactor is of the 'constant speed-dead zone' type, in which the control rod is run at normal speed in the required direction when the error signal overrides a preset level. The study of the closed loop absolute stability was carried out with the describing function method. An analog computer study yielded the optimal values of the setting parameters (relay hysteresis, motor response time), which lead to a minimization of the control steps frequency when the reactivity varies slowly with the xenon poisoning. (authors) [fr

  18. Multi-Stage Optimization-Based Automatic Voltage Control Systems Considering Wind Power Forecasting Errors

    DEFF Research Database (Denmark)

    Qin, Nan; Bak, Claus Leth; Abildgaard, Hans

    2017-01-01

    This paper proposes an automatic voltage control (AVC) system for power systems with limited continuous voltage control capability. The objective is to minimize the operational cost over a period, which consists of the power loss in the grid, the shunt switching cost, the transformer tap change...... electricity control center, where study cases based on the western Danish power system demonstrate the superiority of the proposed AVC system in term of the cost minimization. Monte Carlo simulations are carried out to verify the proposed method on the robustness improvements....

  19. An automatic regulating control system for a graphite moderated reactor using digital techniques

    International Nuclear Information System (INIS)

    Carvalho Goncalves Junior, J. de.

    1989-01-01

    The work propose an automatic regulating control system for a graphite moderated reactor using digital techniques. The system uses a microcomputer to monitor the power and the period, to run the control algorithm, and to generate electronic signals to excite the motor, which moves vertically the control rod banks. A nuclear reactor simulator was developed to test the control system. The simulator consists of a software based on the point kinetic equations and implanted in an analogical computer. The results show that this control system has a good performance and versatility. In addition, the simulator is capable of reproducing with accuracy the behavior of a nuclear reactor. (author)

  20. Application of digital process controller for automatic pulse operation in the NSRR

    International Nuclear Information System (INIS)

    Ishijima, K.; Ueda, T.; Saigo, M.

    1992-01-01

    The NSRR at JAERI is a modified TRIGA Reactor. It was built for investigating reactor fuel behavior under reactivity initiated accident (RIA) conditions. Recently, there has been a need to improve the flexibility of pulsing operations in the NSRR to cover a wide range of accidental situations, including RIA events at elevated power levels, and various abnormal power transients. To satisfy this need, we developed a new reactor control system which allows us to perform 'Shaped Pulse Operation: SP' and 'Combined Pulse Operation: CP'. Quick, accurate and complicated manipulation of control rods was required to realize these operations. Therefore we installed a new reactor control system, which we call an automatic pulse control system. This control system is composed of digital processing controllers and other digital equipments, and is fully automated and highly accurate. (author)

  1. Application of GA optimization for automatic generation control design in an interconnected power system

    International Nuclear Information System (INIS)

    Golpira, H.; Bevrani, H.; Golpira, H.

    2011-01-01

    Highlights: → A realistic model for automatic generation control (AGC) design is proposed. → The model considers GRC, Speed governor dead band, filters and time delay. → The model provides an accurate model for the digital simulations. -- Abstract: This paper addresses a realistic model for automatic generation control (AGC) design in an interconnected power system. The proposed scheme considers generation rate constraint (GRC), dead band, and time delay imposed to the power system by governor-turbine, filters, thermodynamic process, and communication channels. Simplicity of structure and acceptable response of the well-known integral controller make it attractive for the power system AGC design problem. The Genetic algorithm (GA) is used to compute the decentralized control parameters to achieve an optimum operating point. A 3-control area power system is considered as a test system, and the closed-loop performance is examined in the presence of various constraints scenarios. It is shown that neglecting above physical constraints simultaneously or in part, leads to impractical and invalid results and may affect the system security, reliability and integrity. Taking to account the advantages of GA besides considering a more complete dynamic model provides a flexible and more realistic AGC system in comparison of existing conventional schemes.

  2. Application of GA optimization for automatic generation control design in an interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Golpira, H., E-mail: hemin.golpira@uok.ac.i [Department of Electrical and Computer Engineering, University of Kurdistan, Sanandaj, PO Box 416, Kurdistan (Iran, Islamic Republic of); Bevrani, H. [Department of Electrical and Computer Engineering, University of Kurdistan, Sanandaj, PO Box 416, Kurdistan (Iran, Islamic Republic of); Golpira, H. [Department of Industrial Engineering, Islamic Azad University, Sanandaj Branch, PO Box 618, Kurdistan (Iran, Islamic Republic of)

    2011-05-15

    Highlights: {yields} A realistic model for automatic generation control (AGC) design is proposed. {yields} The model considers GRC, Speed governor dead band, filters and time delay. {yields} The model provides an accurate model for the digital simulations. -- Abstract: This paper addresses a realistic model for automatic generation control (AGC) design in an interconnected power system. The proposed scheme considers generation rate constraint (GRC), dead band, and time delay imposed to the power system by governor-turbine, filters, thermodynamic process, and communication channels. Simplicity of structure and acceptable response of the well-known integral controller make it attractive for the power system AGC design problem. The Genetic algorithm (GA) is used to compute the decentralized control parameters to achieve an optimum operating point. A 3-control area power system is considered as a test system, and the closed-loop performance is examined in the presence of various constraints scenarios. It is shown that neglecting above physical constraints simultaneously or in part, leads to impractical and invalid results and may affect the system security, reliability and integrity. Taking to account the advantages of GA besides considering a more complete dynamic model provides a flexible and more realistic AGC system in comparison of existing conventional schemes.

  3. Adjustment of automatic control systems of production facilities at coal processing plants using multivariant physico- mathematical models

    Science.gov (United States)

    Evtushenko, V. F.; Myshlyaev, L. P.; Makarov, G. V.; Ivushkin, K. A.; Burkova, E. V.

    2016-10-01

    The structure of multi-variant physical and mathematical models of control system is offered as well as its application for adjustment of automatic control system (ACS) of production facilities on the example of coal processing plant.

  4. Control-oriented Automatic System for Transport Analysis (ASTRA)-Matlab integration for Tokamaks

    International Nuclear Information System (INIS)

    Sevillano, M.G.; Garrido, I.; Garrido, A.J.

    2011-01-01

    The exponential growth in energy consumption has led to a renewed interest in the development of alternatives to fossil fuels. Between the unconventional resources that may help to meet this energy demand, nuclear fusion has arisen as a promising source, which has given way to an unprecedented interest in solving the different control problems existing in nuclear fusion reactors such as Tokamaks. The aim of this manuscript is to show how one of the most popular codes used to simulate the performance of Tokamaks, the Automatic System For Transport Analysis (ASTRA) code, can be integrated into the Matlab-Simulink tool in order to make easier and more comfortable the development of suitable controllers for Tokamaks. As a demonstrative case study to show the feasibility and the goodness of the proposed ASTRA-Matlab integration, a modified anti-windup Proportional Integral Derivative (PID)-based controller for the loop voltage of a Tokamak has been implemented. The integration achieved represents an original and innovative work in the Tokamak control area and it provides new possibilities for the development and application of advanced control schemes to the standardized and widely extended ASTRA transport code for Tokamaks. -- Highlights: → The paper presents a useful tool for rapid prototyping of different solutions to deal with the control problems arising in Tokamaks. → The proposed tool embeds the standardized Automatic System For Transport Analysis (ASTRA) code for Tokamaks within the well-known Matlab-Simulink software. → This allows testing and combining diverse control schemes in a unified way considering the ASTRA as the plant of the system. → A demonstrative Proportional Integral Derivative (PID)-based case study is provided to show the feasibility and capabilities of the proposed integration.

  5. Development of automated equipment for reduction of personnel radiation exposure in nuclear power plants

    International Nuclear Information System (INIS)

    Ogushi, Akira; Fujii, Masaaki; Mizuno, Katsuhiro.

    1976-01-01

    Described are a mobile remote inspection system and an automatic analyzer for radioactive nuclides in reactor coolant now being developed as a means of reducing personnel radiation exposure in nuclear power plants. In the mobile remote inspection system ''TELEPAT'', a self-propelled vehicle equipped with a thermometer, accelerometer, microphone, ionization chamber, etc. is remote operated from the main control room to inspect the equipment in the reactor building. The automatic analyzer for radioactive nuclides in reactor coolant automates the series of operations ranging from sampling of reactor coolant to measurement of radioactivity and analyses of measured data, with a view to saving labor in radioactivity analysis work while reducing exposure of personnel to radiation. (auth.)

  6. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  7. Development of SM-2 emulsion detector and its application to automatic control of deemulsifying agent addition

    International Nuclear Information System (INIS)

    Wu Hongpei.

    1985-01-01

    Emulsion phenomena had ever occurred in trifattyamine solvent extraction in some uranium mills owing to the presence of the colloidal polysilicic acid in feed solutions with the concentration even as high as >= 0.46 g/l (based on SiO 2 ). Polyether has been used as the deemulsifying agent to remove colloidal polysilicic acid in feed solution in question. In order to reduce the amount of polyether consumption, SM-2 emulsion detector was thus developed and used for automatic control of polyether addition into feed solution. The working principle and basic constitutional structure of SM-2 detector are described. When polyether solution is added into feed solution, certain turbidity occurs owing to the flocculated particles of polysilicic acid. It was found that a linear relationship existed between turbidity and photoelectric pressure difference in millivolts which can be detected by the SM-2 detector. Therefore, it is feasible that the minimum concentration of polysilicic acid, over which emulsion may occurs, can be found through experiments. To take advantage of this linear relationship, we can automatically control the addition of polyether solution in an appropriate amount without occurrence of emulsion phenomenon during solvent extraction. The scheme of automatic control of addition of polyether solution is presented too

  8. Development of a digital automatic control law for steep glideslope capture and flare

    Science.gov (United States)

    Halyo, N.

    1977-01-01

    A longitudinal digital guidance and control law for steep glideslopes using MLS (Microwave Landing System) data is developed for CTOL aircraft using modern estimation and control techniques. The control law covers the final approach phases of glideslope capture, glideslope tracking, and flare to touchdown for automatic landings under adverse weather conditions. The control law uses a constant gain Kalman filter to process MLS and body-mounted accelerometer data to form estimates of flight path errors and wind velocities including wind shear. The flight path error estimates and wind estimates are used for feedback in generating control surface commands. Results of a digital simulation of the aircraft dynamics and the guidance and control law are presented for various wind conditions.

  9. The structure and operation scheme of an automatic and supervisory control system for KEPCO UPFC

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S.J.; Lee, D.W.; Moon, S.I. [Seoul National Univ., Seoul (Korea, Republic of). School of Electrical Engineering

    2007-07-01

    The structure and functions of a control system that can be used for automatic and supervisory control of a unified power flow controller (UPFC) was presented. A UPFC is a device used in power electronic based transmission to allow the independent control of active and reactive power flows as well as the simultaneous control of voltage profile. The Korea Electric Power Corporation (KEPCO) installed a {+-}80 MVA UPFC at the 154 kV Kangjin substation, operated in the Kangjin-Jangheung transmission line. The operation strategies used in both the normal state and emergency state were presented along with a scheme that includes the minimization of active power loss, coordination of voltage/Var control with an under load tap changer (ULTC), and better system security. Although this UPFC is operated by set-point control, it has some limitations, particularly in emergency events. In order to overcome the limitation of set-point control, this paper proposed the automatic and supervisory control system connected to a local SCADA for data exchange. The primary function of the system is to analyze the state of the power system, determine the control objectives and to calculate the optimal power flow. Details of each of these functions was described in this paper along with a detailed algorithm for each scheme. 5 refs., 6 figs.

  10. Long Baseline Stereovision for Automatic Detection and Ranging of Moving Objects in the Night Sky

    Directory of Open Access Journals (Sweden)

    Vlad Turcu

    2012-09-01

    Full Text Available As the number of objects in Earth’s atmosphere and in low Earth orbit is continuously increasing; accurate surveillance of these objects has become important. This paper presents a generic, low cost sky surveillance system based on stereovision. Two cameras are placed 37 km apart and synchronized by a GPS-controlled external signal. The intrinsic camera parameters are calibrated before setup in the observation position, the translation vectors are determined from the GPS coordinates and the rotation matrices are continuously estimated using an original automatic calibration methodology based on following known stars. The moving objects in the sky are recognized as line segments in the long exposure images, using an automatic detection and classification algorithm based on image processing. The stereo correspondence is based on the epipolar geometry and is performed automatically using the image detection results. The resulting experimental system is able to automatically detect moving objects such as planes, meteors and Low Earth Orbit satellites, and measure their 3D position in an Earth-bound coordinate system.

  11. Superposition of automatic and voluntary aspects of grip force control in humans during object manipulation.

    Directory of Open Access Journals (Sweden)

    Frederic Danion

    Full Text Available When moving grasped objects, people automatically modulate grip force (GF with movement-dependent load force (LF in order to prevent object slip. However, GF can also be modulated voluntarily as when squeezing an object. Here we investigated possible interactions between automatic and voluntary GF control. Participants were asked to generate horizontal cyclic movements (between 0.6 and 2.0 Hz of a hand-held object that was restrained by an elastic band such that the load force (LF reached a peak once per movement cycle, and to simultaneously squeeze the object at each movement reversal (i.e., twice per cycle. Participants also performed two control tasks in which they either only moved (between 0.6 and 2.0 Hz or squeezed (between 1.2 and 4.0 Hz the object. The extent to which GF modulation in the simultaneous task could be predicted from the two control tasks was assessed using power spectral analyses. At all frequencies, the GF power spectra from the simultaneous task exhibited two prominent components that occurred at the cycle frequency (ƒ and at twice this frequency (2ƒ, whereas the spectra from the movement and squeeze control task exhibited only single peaks at ƒ and 2ƒ, respectively. At lower frequencies, the magnitudes of both frequency components in the simultaneous task were similar to the magnitudes of the corresponding components in the control tasks. However, as frequency increased, the magnitudes of both components in the simultaneous task were greater than the magnitudes of the corresponding control task components. Moreover, the phase relationship between the ƒ components of GF and LF began to drift from the value observed in the movement control task. Overall these results suggest that, at lower movement frequencies, voluntary and automatic GF control processes operate at different hierarchical levels. Several mechanisms are discussed to account for interaction effects observed at higher movement frequencies.

  12. Automatic Optimization of Focal Point Position in CO2 Laser Welding with Neural Network in A Focus Control System

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    CO2 lasers are increasingly being utilized for quality welding in production. Considering the high cost of equipment, the start-up time and the set-up time should be minimized. Ideally the parameters should be set up and optimized more or less automatically. In this paper a control system...... is designed and built to automatically optimize the focal point position, one of the most important parameters in CO2 laser welding, in order to perform a desired deep/full penetration welding. The control system mainly consists of a multi-axis motion controller - PMAC, a light sensor - Photo Diode, a data...

  13. Practical methods for exposure control/management at nuclear facilities

    International Nuclear Information System (INIS)

    Twiggs, J.A.

    1991-01-01

    Exposure management/reduction is very important to Duke Power Company. Practical exposure control/reduction techniques applied to their reactor vessel head disassembly outage activity have consistently reduced personnel exposure for this task. The following exposure control methods have worked for use and will be the industry's direction for the 1990's. A summary of these methods includes: (a) move the responsibility of exposure management from the Radiation Protection group to the Maintenance group; (b) reduce area source term by removal of source; (c) improve working environments in radiation areas by minimizing protective clothing usage; and (d) maximize the use of electronic instruments to allow remote monitoring

  14. Automatic refueling platform and CRD remote handling device for BWR plant

    International Nuclear Information System (INIS)

    Kato, Hiroaki; Takagi, Kaoru

    1978-01-01

    In BWR plants, machines for replacing fuel assemblies and control rod drives are usually operated directly by personnel. An automatic refueling platform and a CRD remote handling device aiming at radiation exposure reduction and handling perfectness are described, which are already used in BWR plants. Automation of the former is achieved in transporting fuel assemblies between a reactor pressure vessel and a fuel storage pool, shuffling fuel assemblies in a reactor core and moving fuel assemblies in a fuel storage pool. In the latter, replacement of CRDs is nearly all performed remotely. (Mori, K.)

  15. Optoacoustic temperature determination and automatic coagulation control in rabbits

    Science.gov (United States)

    Schlott, Kerstin; Koinzer, Stefan; Ptaszynski, Lars; Luft, Susanne; Baade, Alex; Bever, Marco; Roider, Johann; Birngruber, Reginald; Brinkmann, Ralf

    2011-03-01

    Retinal laser photocoagulation is an established treatment method for many retinal diseases like macula edema or diabetic retinopathy. The selection of the laser parameters is so far based on post treatment evaluation of the lesion size and strength. Due to local pigment variations in the fundus and individual transmission the same laser parameters often lead to an overtreatment. Optoacoustic allows a non invasive monitoring of the retinal temperature increase during retinal laser irradiation by measuring the temperature dependent pressure amplitudes, which are induced by short probe laser pulses. A 75 ns/ 523 nm Nd:YLF was used as a probe laser at a repetition rate of 1 kHz, and a cw / 532 nm treatment laser for heating. A contact lens was modified with a ring-shaped ultrasonic transducer to detect the pressure waves at the cornea. Temperatures were collected for irradiations leading to soft or invisible lesions. Based on this data the threshold for denaturation was found. By analyzing the initial temperature increase, the further temperature development during irradiation could be predicted. An algorithm was found to calculate the irradiation time, which is needed for a soft lesion formation, from the temperature curve. By this it was possible to provide a real-time dosimetry by automatically switching off the treatment laser after the calculated irradiation time. Automatically controlled coagulations appear softer and more uniformly.

  16. Automatic Thermal Control System with Temperature Difference or Derivation Feedback

    Directory of Open Access Journals (Sweden)

    Darina Matiskova

    2016-02-01

    Full Text Available Automatic thermal control systems seem to be non-linear systems with thermal inertias and time delay. A controller is also non-linear because its information and power signals are limited. The application of methods that are available to on-linear systems together with computer simulation and mathematical modelling creates a possibility to acquire important information about the researched system. This paper provides a new look at the heated system model and also designs the structure of the thermal system with temperature derivation feedback. The designed system was simulated by using a special software in Turbo Pascal. Time responses of this system are compared to responses of a conventional thermal system. The thermal system with temperature derivation feedback provides better transients, better quality of regulation and better dynamical properties.

  17. Development of automatic pipe welder for nuclear power plant

    International Nuclear Information System (INIS)

    Iwamoto, Taro; Ando, Shimon; Omae, Tsutomu; Ito, Yoshitoshi; Araya, Takeshi.

    1978-01-01

    Numerous pipings are installed in nuclear power plants, and of course, the reliability of these pipings are very important to preserve the safety of the plants. These pipings undergo periodic inspection yearly, and when some defects are found or some reconstructions to superior systems are made, field welding in the plants is required. When the places to be welded are in containment vessels, the works must be carried out in radiation environment. In order to maintain the highest quality of welding and to reduce the radiation exposure of workers, many skilled workers are required. This automatic pipe welder was developed to solve these problems, aiming at carrying out welding works by remote control at the safe places outside containment vessels. Especially in order to obtain the highest quality of welding, it was not perfectly automated, but the man-machine system so as to enable to utilize the delicate sense of workers was adopted. The visual and contact detecting systems to monitor welding works, remote control system, computer control, light, small and easily installed welding head, grinding and supersonic flow detecting equipments, the power source of transistor switching type, air cooling equipment, and the function for setting welding conditions according to algorithm were added to the welding machine. The outline and main components of this automatic pipe welder are explained. (Kako, I.)

  18. Automatic control and detector for three-terminal resistance measurement

    Science.gov (United States)

    Fasching, George E.

    1976-10-26

    A device is provided for automatic control and detection in a three-terminal resistance measuring instrument. The invention is useful for the rapid measurement of the resistivity of various bulk material with a three-terminal electrode system. The device maintains the current through the sample at a fixed level while measuring the voltage across the sample to detect the sample resistance. The three-electrode system contacts the bulk material and the current through the sample is held constant by means of a control circuit connected to a first of the three electrodes and works in conjunction with a feedback controlled amplifier to null the voltage between the first electrode and a second electrode connected to the controlled amplifier output. An A.C. oscillator provides a source of sinusoidal reference voltage of the frequency at which the measurement is to be executed. Synchronous reference pulses for synchronous detectors in the control circuit and an output detector circuit are provided by a synchronous pulse generator. The output of the controlled amplifier circuit is sampled by an output detector circuit to develop at an output terminal thereof a D.C. voltage which is proportional to the sample resistance R. The sample resistance is that segment of the sample between the area of the first electrode and the third electrode, which is connected to ground potential.

  19. Transient Oscilliations in Mechanical Systems of Automatic Control with Random Parameters

    Science.gov (United States)

    Royev, B.; Vinokur, A.; Kulikov, G.

    2018-04-01

    Transient oscillations in mechanical systems of automatic control with random parameters is a relevant but insufficiently studied issue. In this paper, a modified spectral method was applied to investigate the problem. The nature of dynamic processes and the phase portraits are analyzed depending on the amplitude and frequency of external influence. It is evident from the obtained results, that the dynamic phenomena occurring in the systems with random parameters under external influence are complex, and their study requires further investigation.

  20. Brand and automaticity

    OpenAIRE

    Liu, J.

    2008-01-01

    A presumption of most consumer research is that consumers endeavor to maximize the utility of their choices and are in complete control of their purchasing and consumption behavior. However, everyday life experience suggests that many of our choices are not all that reasoned or conscious. Indeed, automaticity, one facet of behavior, is indispensable to complete the portrait of consumers. Despite its importance, little attention is paid to how the automatic side of behavior can be captured and...

  1. Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality

    International Nuclear Information System (INIS)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2014-01-01

    To study the effect of patient size, body region and modulation strength on tube current and image quality on CT examinations that use automatic tube current modulation (ATCM). Ten physical anthropomorphic phantoms that simulate an individual as neonate, 1-, 5-, 10-year-old and adult at various body habitus were employed. CT acquisition of head, neck, thorax and abdomen/pelvis was performed with ATCM activated at weak, average and strong modulation strength. The mean modulated mAs (mAs mod ) values were recorded. Image noise was measured at selected anatomical sites. The mAs mod recorded for neonate compared to 10-year-old increased by 30 %, 14 %, 6 % and 53 % for head, neck, thorax and abdomen/pelvis, respectively, (P mod was lower than the preselected mAs with the exception of the 10-year-old phantom. In paediatric and adult phantoms, the mAs mod ranged from 44 and 53 for weak to 117 and 93 for strong modulation strength, respectively. At the same exposure parameters image noise increased with body size (P < 0.05). The ATCM system studied here may affect dose differently for different patient habitus. Dose may decrease for overweight adults but increase for children older than 5 years old. Care should be taken when implementing ATCM protocols to ensure that image quality is maintained. circle ATCM efficiency is related to the size of the patient's body. (orig.)

  2. Design and implementation of an automatic pressure-control system for a mobile sprayer for greenhouse applications

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, R.; Pawlowski, A.; Rodriguez, C.; Guzman, J. L.; Sanchez-Hermosilla, J.

    2012-07-01

    This article presents the design and development of an embedded automatic pressure-control system for a mobile sprayer working in greenhouses. The pressure system is mounted on a commercial vehicle, it is composed of two on/off electro valves and one proportional electro valve. The hardware developed is based on an embedded microprocessor and provides a low-cost and robust solution. The resulting embedded system has been tested on a spraying system mounted on a manned vehicle. Furthermore, an easy-tuning non-linear PI (Proportional Integral) controller to achieve the desired pressure profile is designed and implemented in the embedded system. Many physical experiments show the best performance of such controller compared with a typical PI controller. Experiments covering the pressure range from 2 to 14 bar obtained a mean error less than 0.3 bar. Summing up, a low-cost automatic pressure-control system is developed, it ensures a uniform decomposition of the liquid sprayed on plants, and it works properly over a wide variable-pressure range. (Author) 17 refs.

  3. Doosan Experience on I and C Upgrade for Operating NPPs: Control Rod Control System and Automatic Seismic Trip System

    International Nuclear Information System (INIS)

    Nam, C.H.; Kim, K.H.; Lee, D.H.

    2012-01-01

    This paper describes DHIC's experience on upgrading 3 coil type control rod control system(CRCS), 4 coil type control element drive mechanism control system(CEDMCS) and automatic seismic trip system(ASTS). Common main feature of the above systems are full duplex system to prevent unwanted trip and mis-operation. 5 CRCS and CEDMCS have been supplied to Kori 1,2, Ulchin 1,2 and Younggwang 3 since 2010 and 7 CEDMCS are contracted to supply Korea Hydro and Nuclear Power Co.(KHNP) site. Also 16 ASTS are supplied and 12 ASTS will be supplied to operating and new NPPs within 3 years. (author)

  4. Automatic Shape Control of Triangular B-Splines of Arbitrary Topology

    Institute of Scientific and Technical Information of China (English)

    Ying He; Xian-Feng Gu; Hong Qin

    2006-01-01

    Triangular B-splines are powerful and flexible in modeling a broader class of geometric objects defined over arbitrary, non-rectangular domains. Despite their great potential and advantages in theory, practical techniques and computational tools with triangular B-splines are less-developed. This is mainly because users have to handle a large number of irregularly distributed control points over arbitrary triangulation. In this paper, an automatic and efficient method is proposed to generate visually pleasing, high-quality triangular B-splines of arbitrary topology. The experimental results on several real datasets show that triangular B-splines are powerful and effective in both theory and practice.

  5. Some experimental results for an automatic helium liquefier

    International Nuclear Information System (INIS)

    Watanabe, T.; Kudo, T.; Kuraoka, Y.; Sakura, K.; Tsuruga, H.; Watanabe, T.

    1984-01-01

    This chapter describes the testing of an automatic cooldown system. The liquefying machine examined is a CTi Model 1400. The automatic helium gas liquefying system is operated by using sequence control with a programmable controller. The automatic mode is carried out by operation of two compressors. The monitoring system consists of 41 remote sensors. Liquid level is measured by a superconducting level meter. The J-T valve and return valve, which require precise control, are operated by pulse motors. The advantages of the automatic cooldown system are reduced operator man power; temperatures and pressures are changed smoothly, so that the flow chart of automation is simple; and the system makes continuous liquefier operation possible

  6. Hexavalent chromium exposures and exposure-control technologies in American enterprise: results of a NIOSH field research study.

    Science.gov (United States)

    Blade, L M; Yencken, M Story; Wallace, M E; Catalano, J D; Khan, A; Topmiller, J L; Shulman, S A; Martinez, A; Crouch, K G; Bennett, J S

    2007-08-01

    The National Institute for Occupational Safety and Health (NIOSH) conducted 21 field surveys in selected industries to characterize workers' exposures to hexavalent chromium-containing airborne particulate and to evaluate existing technologies for controlling these exposures. Hexavalent chromium Cr(VI) is a respiratory irritant and chronic inhalation may cause lung cancer. Primary evaluation methods included collection of full work shift, personal breathing-zone (PBZ) air samples for Cr(VI), measurement of ventilation system parameters, and documentation of processes and work practices. This study emphasized evaluation of engineering exposure control measures, so PBZ exposures were measured on the outside of personal protective equipment, for example, respirators. Field surveys were conducted in two chromium electroplating facilities, including one where full-shift PBZ exposures to Cr(VI) ranged from 3.0 to 16 times the 1 micro g/m(3)NIOSH recommended exposure limit (REL) despite several engineering controls on the plating tanks. At a painting and coating facility that used Cr(VI)-containing products, full-shift exposures of painters and helpers (2.4 to 55 micro g/m(3)) exceeded the REL, but LEV effectiveness was limited. Other operations evaluated included welding in construction; metal cutting operations on chromium-containing materials in ship breaking; chromate-paint removal with abrasive blasting; atomized alloy-spray coating; foundry operations; printing; and the manufacture of refractory brick, colored glass, prefabricated concrete products, and treated wood products. NIOSH researchers concluded that, in many of the evaluated processes, Cr(VI) exposures at or below the current NIOSH REL are achievable. However, for some processes, it is unclear whether controlling exposures to this range is consistently achievable without respirator use. Some operations involving the application of coatings and finishes may be among those most difficult to control to this

  7. On the question of the necessity of implementation of automatic control systems in timber industry

    Science.gov (United States)

    Khasanov, E. R.; Zelenkov, P. V.; Petrosyan, M. O.; Murygin, A. V.; Laptenor, V. D.

    2016-04-01

    The paper considers the necessity of implementation of automatic control systems on the level of forest farms management and timber industry. Main areas of activity, which currently subjected to automation, are revealed. Objectives, which solved by implementation of APCS, are identified.

  8. Automatization of welding for nuclear power equipments and facilities

    International Nuclear Information System (INIS)

    Tamai, Yasumasa; Matsumoto, Teruo; Koyama, Takaichi

    1980-01-01

    For the requirement of high reliability in the construction of nuclear power plants and the reduction of radiation exposure in the modefying works of existing plants, the automation and remote operation of welding have increased their necessity. In this paper, the present state of the automation of welding for making machines, equipments and pipings for nuclear power plants in Hitachi Ltd. is described, and the aim of developing the automation, the features of the equipments and the state of application to actual plants are introduced, centering around the automation of welding for large structures such as reactor containment vessels and the remote type automatic welding system for pipings. By these automations, the large outcomes were obtained in the improvement of welding quality required for the machines and equipments for atomic energy. Moreover, the conspicuous results were also obtained in case of the peculiar works to nuclear power plants, in which the reduction of the radiation exposure related to human bodies and the welding of high quality are demanded. The present state of the automation of welding for nuclear installations in Hitachi Ltd., the development of automatic welding equipments and the present state of application to actual plants, and the development and application of the automatic pipe working machine for reducing radiation exposure are explained. (Kako, I.)

  9. Reliability analysis of the automatic control of the A-1 power plant coolant temperature

    International Nuclear Information System (INIS)

    Kuklik, B.; Semerad, V.; Chylek, Z.

    Reliability analysis of the automatic control of the A-1 reactor coolant temperature is performed taking into account the effect of both the dependent failures and the routine maintenance of control system components. In a separate supplement, reliability analysis is reported of coincidence systems of the A-1 power plant reactor. Both safe and unsafe failures are taken into consideration as well as the effect of maintenance of the respective branch elements

  10. Mathematics of an automatic control system for ventilation of gassy coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Puchkov, L.A.; Bakhvalov, L.A.; Kravchenko, A.G.

    1987-09-01

    Describes and presents a circuit diagram of an automatic control system introduced to control ventilation in the Kommunist mine belonging to the Oktyabr'ugol' coal mining association. The system comprises: sensors to register the parameters of the mine atmosphere (e.g. methane and air flow rate); communications channels and remote control devices to convert and transmit the data; a CM-4 computer with a high-speed processor, an 128-256 kByte operating memory, external memory devices, polydiaphragm air flow controllers, devices for controlling the electric drive of the main ventilation system, devices for collecting, processing and displaying the data. This system uses two groups of algorithms: algorithms for a data subsystem responsible for centralized control of the mine atmosphere parameters and a control subsystem which forms and implements the necessary control commands. The main software is the DISMAIN program. Introducing this system increased the productivity of the mine by 2%, reduced energy consumption by 5-7% and increased safety levels. 2 refs

  11. Control Strategy for Automatic Gantry Crane Systems: A Practical and Intelligent Approach

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2007-12-01

    Full Text Available The use of gantry crane systems for transporting payload is very common in building constructions. However, moving the payload using the crane is not an easy task especially when strict specifications on the swing angle and on the transfer time need to be satisfied. Various attempts in controlling gantry cranes system based on open- loop and closed-loop control systems were proposed. However, most of the proposed controllers were designed based on the model and parameter of the crane system. In general, modeling and parameter identifications are troublesome and time consuming task. To overcome this problem, in this paper, a practical and intelligent control method for automatic gantry crane is introduced and evaluated experimentally. The results show that the proposed method is not only effective for controlling the crane but also robust to parameter variation.

  12. Control Strategy for Automatic Gantry Crane Systems: A Practical and Intelligent Approach

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2008-11-01

    Full Text Available The use of gantry crane systems for transporting payload is very common in building constructions. However, moving the payload using the crane is not an easy task especially when strict specifications on the swing angle and on the transfer time need to be satisfied. Various attempts in controlling gantry cranes system based on open- loop and closed-loop control systems were proposed. However, most of the proposed controllers were designed based on the model and parameter of the crane system. In general, modeling and parameter identifications are troublesome and time consuming task. To overcome this problem, in this paper, a practical and intelligent control method for automatic gantry crane is introduced and evaluated experimentally. The results show that the proposed method is not only effective for controlling the crane but also robust to parameter variation.

  13. Exposure to crystalline silica at Alberta work sites: review of controls.

    Science.gov (United States)

    Radnoff, Diane; Todor, Maria S; Beach, Jeremy

    2015-01-01

    From 2009 to 2013, Alberta Jobs, Skills, Training, and Labour (JSTL) conducted a project to evaluate exposure to crystalline silica and assess controls to protect workers. Information on exposure results has been previously reported; this article discusses the data collected on workplace controls. Information on work site controls was collected during exposure assessments consisting of qualitative information on controls in place and used by workers at the time of the assessments. Where there was sufficient data, the information was further analyzed to evaluate the impact of a particular control. While many types of controls were observed, they were not always effective or in use. The control available most often was respiratory protective equipment (RPE). Generally, when respirators were used, they were correctly selected for the level of measured exposure. However, not all workers who were potentially overexposed wore respirators at the time of the assessments. When the use of respirators was taken into account, about one-third of workers were still potentially exposed over the Alberta occupational exposure limit. The industries with the highest levels of exposure tended to be those with the most unprotected workers. Issues were identified with the use of improper work practices such as dry cleaning methods, lack of documented work procedures, poor housekeeping, and lack of training which may have contributed to worker exposure levels. There is a wide range in the efficacy of controls, particularly engineering controls. Most of the literature focuses on engineering controls; however administrative controls also play a role in reducing worker exposure. Data collected in this work indicated that simple changes to work procedures and behavior (such as improved housekeeping) may be effective, low-cost ways to reduce workplace exposure. More study is required to evaluate the impact and efficacy of administrative controls such as housekeeping and training. Employers

  14. Automatic Traffic-Based Internet Control Message Protocol (ICMP) Model Generation for ns-3

    Science.gov (United States)

    2015-12-01

    more protocols (especially at different layers of the OSI model ), implementing an inference engine to extract inter- and intrapacket dependencies, and...ARL-TR-7543 ● DEC 2015 US Army Research Laboratory Automatic Traffic-Based Internet Control Message Protocol (ICMP) Model ...ICMP) Model Generation for ns-3 by Jaime C Acosta and Felipe Jovel Survivability/Lethality Analysis Directorate, ARL Felipe Sotelo and Caesar

  15. Automatic control with fuzzy logic of home-made beer production in maceration and cooking stages

    Directory of Open Access Journals (Sweden)

    Mariano Luján Corro

    2010-06-01

    Full Text Available The process of home-made beer production in the malt maceration and cooking stages was controlled automatically with fuzzy logic, across different performers considering the time and temperature of the process, using 2009LabVIEW. The equipment was mainly composed of three 20 L capacity stainless steel containers (water supply, maceration and cooking, an additional hops container, a data acquisition card (PIC 16F877a micro controller, three LM35 temperature sensors and 11 on/off type performers, which were governed by a total of 47 Mandani type fuzzy rules with trapezoidal membership functions, using the method of center area for the defuzzification. The performers: electrovalves (5, pumps (2, heaters (3 and a stirrer, in approximately 4 hours, were adequately controlled in their early maceration and cooking stages. The beer obtained by automatic control with fuzzy logic in the maceration and cooking stages, had the following characteristics: 0.98 g/cm3 of density, 3.9 of pH, total acidity expressed as 0.87% of lactic acid, 6.2ºGL of alcoholic degree and 0.91% w/v of CO2 percentage.

  16. Automatic control of the water level of steam generators from 0% to 100% of the load

    International Nuclear Information System (INIS)

    Hocepied, R.; Debelle, J.; Timmermans, A.; Lams, J.-L.; Baeyens, R.; Eussen, G.; Bassem, G.

    1978-01-01

    The water level of a steam generator is hard to control manually and it is practically impossible for a human operator to react correctly to every important perturbation. These phenomena are further accentuated during the start-up at low load and at low feedwater temperature. The control schemes traditionally provided do not permit satisfactory automatic level control during all operating circumstances. Adaptions of the control system permit all the problems encountered to be solved: automatic control of the level in the steam generators is possible from 0% to 100% of the load and also when large-scale perturbations occur. Such a result has been obtained by use of systematic methods for the analysis of the steam generator's behaviour. These methods have also been used to verify the performance of the control system. The control system installed at the Doel nuclear power station prevents most of the reactor or turbine trip-outs caused by level deviations occurring during start-up and low-load operation. It also minimizes the effects on the unit of incidents such as tripping the unit on house load, safety tripping, fast run-back on reduced load, etc. The principles used are applicable to the control of steam generators of all pressurized water reactor power stations. (author)

  17. Monitoring and control of occupational radiation exposure in Switzerland

    International Nuclear Information System (INIS)

    Moser, M.

    1997-01-01

    Occupational exposure is the most prominent example for the prolonged exposure to low level ionizing radiation characterized by low doses and dose rates. In this paper the occupational exposure in Switzerland is presented and the regulatory control of this exposure in the framework of the new radiation protection regulations is discussed. (author)

  18. Culture, attribution and automaticity: a social cognitive neuroscience view.

    Science.gov (United States)

    Mason, Malia F; Morris, Michael W

    2010-06-01

    A fundamental challenge facing social perceivers is identifying the cause underlying other people's behavior. Evidence indicates that East Asian perceivers are more likely than Western perceivers to reference the social context when attributing a cause to a target person's actions. One outstanding question is whether this reflects a culture's influence on automatic or on controlled components of causal attribution. After reviewing behavioral evidence that culture can shape automatic mental processes as well as controlled reasoning, we discuss the evidence in favor of cultural differences in automatic and controlled components of causal attribution more specifically. We contend that insights emerging from social cognitive neuroscience research can inform this debate. After introducing an attribution framework popular among social neuroscientists, we consider findings relevant to the automaticity of attribution, before speculating how one could use a social neuroscience approach to clarify whether culture affects automatic, controlled or both types of attribution processes.

  19. Automatic Control of Arc Process for Making Carbon Nanotubes

    Science.gov (United States)

    Scott, Carl D.; Pulumbarit, Robert B.; Victor, Joe

    2004-01-01

    An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

  20. Automatic control system for uniformly paving iron ore pellets

    Science.gov (United States)

    Wang, Bowen; Qian, Xiaolong

    2014-05-01

    In iron and steelmaking industry, iron ore pellet qualities are crucial to end-product properties, manufacturing costs and waste emissions. Uniform pellet pavements on the grate machine are a fundamental prerequisite to ensure even heat-transfer and pellet induration successively influences performance of the following metallurgical processes. This article presents an automatic control system for uniformly paving green pellets on the grate, via a mechanism mainly constituted of a mechanical linkage, a swinging belt, a conveyance belt and a grate. Mechanism analysis illustrates that uniform pellet pavements demand the frontend of the swinging belt oscillate at a constant angular velocity. Subsequently, kinetic models are formulated to relate oscillatory movements of the swinging belt's frontend to rotations of a crank link driven by a motor. On basis of kinetic analysis of the pellet feeding mechanism, a cubic B-spline model is built for numerically computing discrete frequencies to be modulated during a motor rotation. Subsequently, the pellet feeding control system is presented in terms of compositional hardware and software components, and their functional relationships. Finally, pellet feeding experiments are carried out to demonstrate that the control system is effective, reliable and superior to conventional methods.