WorldWideScience

Sample records for area monitoring dosimetry

  1. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    CERN Document Server

    Cooper, J R

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  2. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    International Nuclear Information System (INIS)

    COOPER, J.R.

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual

  3. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    Energy Technology Data Exchange (ETDEWEB)

    COOPER, J.R.

    2000-04-17

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  4. Personal dosimetry and area monitoring for neutrons and radon in workplaces

    International Nuclear Information System (INIS)

    Tommasino, L.

    2001-01-01

    The first successful applications of damage track detectors in radiation protection have been made in the early 1970s in personal dosimetry of neutrons, radon and its progenies. Most of the scientists actively engaged in the solution of the complex problem of personal neutron dosimetry by damage track detectors-SSNTD, have attempted to develop individual radon monitoring for exposure in mines by using the same SSNTDs. In late 1970s and the early 1980s, new radon monitoring devices based on SSNTDs have been developed to measure radon in soil, mainly for applications in uranium prospecting or more generally in earth sciences. Most of the radon monitors, developed since then for completely different applications in mind, have been used later for large scale survey of indoor radon. With the current implementation within Europe of the European Union Directive 96/29, applications of damage track detectors will increase drastically, specially for the assessment of the exposure of the workers to natural sources of radiation. In this case, the early work on personal neutron/radon dosimetry, is highly valuable to tackle these new problems of individual monitoring

  5. Comparing personal alpha dosimetry with the conventional area monitoring-time weighting methods of exposure estimation: a Canadian assessment

    International Nuclear Information System (INIS)

    Balint, A.B.; Viljoen, J.

    1988-01-01

    An experimental personal alpha dosimetry program for monitoring exposures of uranium mining facility workers in Canada has been completed. All licenced operating mining facilities were participating. Dosimetry techniques, description of dosimeters used by licences, performance and problems associated with the implementation of the programme as well as technical and administrative advantages and difficulties experienced are discussed. Area monitoring-time weighting methods used and results obtained to determine individual radon and thoron daughter exposure and exposure results generated by using dosimeters are assessed and compared

  6. Proceedings of the specialist meeting on personal dosimetry and area monitoring suitable for radon and daughter products

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The programme of work of the OECD Nuclear Energy Agency includes topics relating to radiation and environmental protection matters in mining and milling operations. A first Specialist Meeting on Personal Dosimetry and Area Monitoring suitable for Radon and Daughter Products was organised in October 1976 at Elliot Lake, Canada. The proceedings were published by NEA some months later. Following an enquiry among interested persons, NEA decided to organise a new meeting on the same subject in Paris from 20th to 22nd November 1978. The meeting dealt with questions relating to personal dosimetry techniques, the monitoring of the atmosphere in mines and their neighbourhood, as well as in buildings

  7. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  8. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  9. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  10. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  11. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  12. Personnel radiation monitoring by thermoluminescence dosimetry (2000-2001)

    International Nuclear Information System (INIS)

    Mi-Cho-Cho, Daw; Hla-Hla-Win, Daw; Thin-Thin-Kraing

    2001-01-01

    Thermoluminescence dosimetry service was introduced in 1991. Personnel who exposed directly or indirectly to radiation is monitored by thermoluminescent dosimeter. TL materials used for thermoluminescent dosimeter are in the form of thin disc. Personnel whole-body and extremity doses are measured by thermoluminescence dosimetry. The Harshaw Model 4500 TLD reader and Vinten 654E TLD reader are used for TLD evaluation. At present about 600 radiation workers are provided with TLD for routine monitoring. It was found that most personnel had received within permissible dose recommended by the International Commission on Radiological Protection (ICRP). (author)

  13. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  14. Individual monitoring dosimetry in Europe

    International Nuclear Information System (INIS)

    Menzel, H.G.

    1991-01-01

    This report discusses the various types of individual monitoring systems presently in use within the European community and neutron dosimetry research being coordinated by the EURADOS working group. Research is currently being conducted on nuclear track dosimeters, primarily with CR-39 (TM), and TLD-albedo dosimeters. Studies are being conducted on the energy and angular response of each type of dosimeter. Because the response of dosimeters depends on the energy of the neutrons, it is necessary to have spectral information to accurately assess the dose. Neutron energy spectrum measurements are being performed in typical work place environments. Work is also progressing on development of calibration sources which will be representative of the neutron energy spectrum found in typical neutron exposure situations. This work utilizes 14 MeV neutrons incident on a uranium block with various other filters. Research is also continuing on neutron dosimetry using tissue equivalent proportional counters and microdosimetric techniques. The results of intercomparisons between several different instruments are discussed. In addition to personnel dosimetry, these systems are being used to record the dose to passengers and flight crews aboard commercial aircraft

  15. Neutron dosimetry. Environmental monitoring in a BWR type reactor

    International Nuclear Information System (INIS)

    Tavera D, L.; Camacho L, M.E.

    1991-01-01

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  16. Dosimetry Control: Technic and methods. Proceedings of the international workshop 'Actual problems of dosimetry'

    International Nuclear Information System (INIS)

    Lyutsko, A.M.; Nesterenko, V.B.; Chudakov, V.A.; Konoplya, E.F.; Milyutin, A.A.

    1997-10-01

    There is a number of unsolved problems of both dosimetric and radiometric control, questions of the biological dosimetry, reconstruction of dozes of irradiation of the population at radiation incidents, which require coordination of efforts of scientists in various areas of a science. The submitted materials are grouped on five units: dosimetry engineering, biological dosimetry and markers of radiation impact, dosimetry of a medical irradiation, normative and measurement assurance of the dosimetric control, monitoring and reconstruction of dozes at radiation incidents

  17. The task of official personal monitoring in Germany using electronic dosimetry systems

    International Nuclear Information System (INIS)

    Huebner, Stephan; Wahl, Wolfgang; Busch, Frank; Martini, Ekkehard

    2008-01-01

    Full text: Since the establishment of the first German personal monitoring services as competent measuring bodies in the year 1952, official personal dosimetry is carried out using passive dosimeters such as film batches, RPL- and TL-dosimeters solely. On the other hand, electronic dosimeters are in use in some big institutions like Nuclear Power Plants, hospitals or industrial units for operational purposes. In most cases, these dosimeters are regulated by competent authorities. For more than 20 years electronic dosimeters proved their worth of being appropriate personal dosimeters. Since 2001 concepts to implement electronic personal dosimeters into the official individual monitoring of occupational exposed workers were developed in different research projects. The EU market of personal dosimetry changes to an open and competitive one, the number of outside workers, especially during the outages of Nuclear Power Plants increases, the landscape of customers is getting more and more heterogeneous. Being able to face these tasks of a sustainable personal monitoring requires the introduction of modern electronic dosimeters into to the official monitoring. Doing so, the needed prompt exchange of dose-data between different monitoring services as well as between the customers and the related monitoring service can be warranted. In cooperation with the industry, competent authorities and a research centre a method for official dosimetry using electronic dosimetry systems was developed, realised and tested successfully by the three big monitoring services of Germany. These investigations are supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety. For this purpose a network between customers and monitoring services was built up in order to monitor people, who work in different places related to different measuring bodies in only one period of surveillance. (author)

  18. Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 2000

    International Nuclear Information System (INIS)

    Bivins, Steven R; Stoetzel, Gregory A

    2001-01-01

    Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM) in January 1993. This program is to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a) (1)-(4) and Article 511.1 of the DOE Standard Radiological Control, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually, and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-2000 confirm that personnel dosimetry is not needed for individuals located in areas monitored by the program

  19. Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1997

    International Nuclear Information System (INIS)

    Bivins, S.R.; Stoetzel, G.A.

    1998-07-01

    In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the US Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a) (1)--(3) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually, and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years (CY) 1993--1996 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 93 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during CY 1997. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusions that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas

  20. Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 1998

    International Nuclear Information System (INIS)

    GA Stoetzel; SR Bivins

    1999-01-01

    In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-1997 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 97 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during calendar year 1998. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas

  1. Digital dosimetry and personal and environmental monitoring assembly

    International Nuclear Information System (INIS)

    Cerovac, Z.; Radalj, Z.; Prlic, I.; Cerovac, H.

    1996-01-01

    Film+TLD and film or TLD Dosimetry have a certain delay in dose reporting, since the reports on occupational doses are usually available to the users within 40 days after the actual exposure. This is particularly important when the dose is received within the short-time interval or when the radiation source has some technical failures. For this reason, the additional monitoring is recommendable. The common Dosimetry service in Croatia is well established and the data available shows that over 80% of occupationally exposed persons are working in medical facilities, mainly with x-ray sources. Dosimetry services in the country are providing three types of dosemeters, film dosemeter badge, film+TLD dosemeter badge or plane TLD badge. We have decided to introduce the palette of digital pocket dosemeters to be used at different workplaces occupationally exposed to ionizing radiation. After the first experience with the ALARA 1G digital dosemeter it came out that this type of ionizing radiation measuring device is suitable for the various non-occupational purposes. After some technical improvement and with some telecommunication electronics this device is usable as a point environmental measuring station. This means that the probe of the record any change in normal environmental radiation field, send the data to the central station and to raise alarm if necessary. That is why we have made a prototype for environmental monitoring able to be connected to any kind of telecommunication net. (author)

  2. Workplace monitoring of mixed neutron-photon radiation fields and its contribution to external dosimetry

    International Nuclear Information System (INIS)

    Schuhmacher, H.

    2011-01-01

    Workplace monitoring is a common procedure for determining measures for routine radiation protection in a particular working environment. For mixed radiation fields consisting of neutrons and photons, it is of increased importance because it contributes to the improved accuracy of individual monitoring. An example is the determination of field-specific correction factors, which can be applied to the readings of personal dosemeters. This paper explains the general problems associated with individual dosimetry of neutron radiation, and describes the various options for workplace monitoring. These options cover a range from the elaborate field characterisation using transport calculations or spectrometers to the simpler approach using area monitors. Examples are given for workplaces in nuclear industry, at particle accelerators and at flight altitudes. (authors)

  3. Accuracy of helium accumulation fluence monitor for fast reactor dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Chikara; Aoyama, Takafumi [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-03-01

    A helium (He) accumulation fluence monitor (HAFM) has been developed for fast reactor dosimetry. In order to evaluate the measurement accuracy of neutron fluence by the HAFM method, the HAFMs of enriched boron (B) and beryllium (Be) were irradiated in the Fast Neutron Source Reactor `YAYOI`. The number of He atoms produced in the HAFMs were measured and compared with the calculated values. As a result of this study, it was confirmed that the neutron fluence could be measured within 5 % by the HAFM method, and that met the required accuracy for fast reactor dosimetry. (author)

  4. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  5. 5th symposium on neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, F

    1985-03-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of /sup 252/Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.).

  6. 5th symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.

    1985-01-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of 252 Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.)

  7. Calibration of radiation protection area monitoring instruments in Sudan

    International Nuclear Information System (INIS)

    Suliman, I.I.; Youssif, B.E.; Beineen, A.A.; Hassan, M.

    2010-01-01

    This article presents results of measurements for the calibration of radiation protection area monitoring instruments carried out during the period 2006-2008 at Secondary Standard Dosimetry Laboratory of Sudan. The work performed included quality assurance measurements, measurements for the dosimeter calibrations and uncertainty analysis. Calibrations were performed using 137 Cs gamma ray sources produced by OB 85 and OB 34/1 gamma calibrators producing air kerma rate that ranged from 10 μGy/h to 50 mGy/h. Area monitoring instruments were calibrated in terms of ambient dose equivalent, H*(10) derived using air kerma to ambient dose equivalent conversion coefficients. Results are presented for 78 area monitoring instruments representing most commonly used types in Sudan. Radioactive check source measurements for the reference chamber showed deviation within 1% limit. The accuracy in the beam output measurements was within 5% internationally considered as acceptable. The results highlighted the importance of radiation protection calibrations. Regulations are further need to ensure safety aspect really meet the required international standards.

  8. Revue of some dosimetry and dose assessment European projects

    International Nuclear Information System (INIS)

    Bolognese-Milsztajn, T.; Frank, D.; Lacoste, V.; Pihet, P.

    2006-01-01

    internal exposure monitoring programmes. Current monitoring programmes were critically reviewed, the major sources of uncertainty in assessed internal dose investigated, and guidance formulated on factors such as programme design, choice of method/techniques, monitoring intervals, and monitoring frequency. OMINEX promoted a common and harmonized approach to the design and implementation of internal dose monitoring programmes throughout the EU. The Coordination Action 'CONRAD' of the 6. Framework Programme will continue the work initiated within the 5. Framework Program in specific areas of dosimetry requiring coordination of research activities: computational dosimetry, internal dosimetry, complex mixed radiation fields at workplaces and radiation protection dosimetry of medical staff. (authors)

  9. Evaluation of the environmental equivalent dose rate using area monitors for neutrons in clinical linear accelerators; Avaliacao da taxa de equivalente de dose ambiente utilizando monitores de area para neutrons em aceleradores lineares clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da, E-mail: asalgado@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Batista, Delano V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The Neutron Laboratory of the Radioprotection and Dosimetry Institute - IRD/CNEN, Rio de Janeiro, Brazil, initiated studies on the process of calibration of neutron area monitors and the results of the measurements performed at radiotherapy treatment rooms, containing clinical accelerators

  10. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  11. Direct internal dosimetry. A new way for routine incorporation monitoring of γ-emitting radionuclides

    International Nuclear Information System (INIS)

    Doerfel, H.

    1996-01-01

    The INDOS detector system offers the following advantages with respect to routine incorporation monitoring: The measurement is performed automatically and there is no need for trained staff. The measuring time is short and thus a relative large number of persons may be monitored with a relative high measuring frequency. First estimates of the individual effective dose equivalent rate are available immediately after the measurement. 1) The direct determination of the dose equivalent in principle is more precise than the conventional procedures for internal dosimetry, because (i) the retention of radionuclides in the body may be measured explicitly and (ii) the dependence of the dose equivalent on the body proportions is corrected implicitly. 2) The measuring procedure is comparable to the external dosimetry with respect to accuracy and lower limit of detection. Thus, the results of internal and external dosimetry can be summed up in an easy and reasonable manner. 3) The detector system can be installed in any building; it also can be installed as a mobile unit in a car or a container for long distance transportation by aircraft or train. 4) Last but not least, the cost for monitoring with INDOS is much lower than for the conventional monitoring procedures using whole body counters. (author)

  12. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  13. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  14. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  15. Evaluation of the environmental equivalent dose rate using area monitors for neutrons in clinical linear accelerators

    International Nuclear Information System (INIS)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Batista, Delano V.S.

    2009-01-01

    The Neutron Laboratory of the Radioprotection and Dosimetry Institute - IRD/CNEN, Rio de Janeiro, Brazil, initiated studies on the process of calibration of neutron area monitors and the results of the measurements performed at radiotherapy treatment rooms, containing clinical accelerators

  16. Trends in light water reactor dosimetry programs

    International Nuclear Information System (INIS)

    Rahn, F.J.; Serpan, C.Z.; Fabry, A.; McElroy, W.N.; Grundl, J.A.; Debrue, J.

    1977-01-01

    Dosimetry programs and techniques play an essential role in the continued assurance of the safety and reliability of components of light water reactors. Primary concern focuses on the neutron irradiation embrittlement of reactor pressure vessels and methods by which the integrity of a pressure vessel can be predicted and monitored throughout its service life. Research in these areas requires a closely coordinated program which integrates the elements of the calculational and material sciences, the development of advanced dosimetric techniques and the use of benchmarks and validation of these methods. The paper reviews the status of the various international efforts in the dosimetry area

  17. Personnel radiation monitoring by thermoluminescence dosimetry (1995-96)

    International Nuclear Information System (INIS)

    Daw Mi Cho Cho; Daw Yi Yi Khin; Daw San San; U Maung Maung Tin; Daw Hla Hla Win

    2001-01-01

    Personnel radiation monitoring which is the dose assessment of individual doses from external radiation received by radiation workers has been carried out by Thermoluminescence Dosimetry system consisting of a Vinten Toledo TLD reader, LiF dosimeters and associated equipment. The exposed TLD dosimeters were measured by TLD reader and the dose evaluation and dose registration were done on personal computer. Due to the records of 1995-96, most of the radiation workers complied with the permissible dose recommended by IAEA and ICRP 60. (author)

  18. Sixth symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    1987-01-01

    This booklet contains all abstracts of papers presented in 13 sessions. Main topics: Cross sections and Kerma factors; analytical radiobiology; detectors for personnel monitoring; secondary charged particles and microdosimetric basis of q-value for neutrons; personnel dosimetry; concepts for radiation protection; ambient monitoring; TEPC and ion chambers in radiation protection; beam dosimetry; track detectors (CR-39); dosimetry at biomedical irradiation facilities; health physics at therapy facilities; calibration for radiation protection; devices for beam dosimetry (TLD and miscellaneous); therapy and biomedical irradiation facilities; treatment planning. (HP)

  19. Dosimetry and monitoring of X-rays narrow beams produced by linear particle accelerator, for using in radiosurgery

    International Nuclear Information System (INIS)

    Campos, J.C.F.; Vizeu, D.M.

    1987-01-01

    The main characteristics of X-rays narrow beams dosimetry and monitoring are examined, aiming the introduction of this system in brain radiosurgery. The non-protocolize detectors are used, once that the detectors used in therapy by megavoltage were projected for dosimetry with an irradiation field above 40 mm diameter. (C.G.C.) [pt

  20. Dosimetry optimization at COGEMA-La Hague

    International Nuclear Information System (INIS)

    Kalimbadjian, J.

    2000-01-01

    At the present time, the la Hague site strives to apply international recommendations together with national regulations concerning radiation protection, and especially the respect of limitation and optimization principles. The application of these principles is based on the implementation of a passive dosimetry and an active dosimetry. The monthly passive dosimetry is monitored by means of a photographic dosimetry film, completed with lithium fluorine thermoluminescent film badges. This personal dosimetry common to X, β, γ and neutron radiations is carried out in close relationship between the Radiation Protection Department, the Occupational Medical Department and the staff running the Plant. The application or ALARA's principle as well as that of radiation protection optimization implies to implement a complementary active dosimetry enabling to gain in real time, the personal dosimetry of each intervening person, either they be COGEMA's workers or external companies'. This active dosimetry provides with following information: This preventive dosimetry is based on the knowledge of doses integration in real time and is fitted with alarm thresholds according to the total amount of doses and dose rates. Thresholds on the dose rate are also set relatively to the radiological environment. This knowledge of doses and dose rates allows a stricter management of the works, while analyzing them according to the nature of the work, to the location and to the skills of the intervening people. This dosimetry allows to analyze and optimize doses integration according to the works nature for the whole intervening staff. The la Hague Site has developed an active personal dosimetry system, common to every intervening person, COGEMA or external companies. The DOSICARD was thus elaborated, shaped as an electronic dosimeter fitted with an alarm and a smart card. The access to controlled areas is conditioned to information given by the DOSICARD concerning medical aptitudes and

  1. Dosimetry in nuclear power plants

    International Nuclear Information System (INIS)

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  2. 11. International conference on solid radiation dosimetry

    International Nuclear Information System (INIS)

    Krylova, I.V.

    1996-01-01

    The main problems discussed during the international conference on solid radiation dosimetry which took place in June 1995 in Budapest are briefly considered. These are the basic physical processes, materials applied for dosimetry, special techniques, personnel monitoring, monitoring of environmental effects, large-dose dosimetry, clinic dosimetry, track detector used for dosimetry, dosimetry in archaeology and geology, equipment and technique for dosimetric measurements. The special attention was paid to superlinearity in the TLD-100 (LiF, Mg, Ti) response function when determining doses of gamma radiation, heavy charged particles, low-energy particle fluxes in particular. New theoretical models were considered

  3. Super Phenix. Monitoring of structures subject to irradiation. Neutron dosimetry measurement and calculation program

    International Nuclear Information System (INIS)

    Cabrillat, J.C.; Arnaud, G.; Calamand, D.; Manent, G.; Tavassoli, A.A.

    1984-09-01

    For the Super Phenix reactor, the evolution, versus the irradiation of the mechanical properties of the core diagrid steel is the object of studies and is particularly monitored. The specimens irradiated, now in PHENIX and will be later irradiated in SUPER PHENIX as soon as the first operating cycles. An important dosimetry program coupling calculation and measurement, is parallely carried out. This paper presents the reasons, the definition of the structure, of the development and of materials used in this program of dosimetry, as also the first results of a calculation-measurement comparison [fr

  4. Internal dosimetry hazard and risk assessments: methods and applications

    International Nuclear Information System (INIS)

    Roberts, G.A.

    2006-01-01

    Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry programmes. This paper describes various methods for performing hazard and risk assessments which are being developed by RWE NUKEM Limited Approved Dosimetry Services to provide an indication when routine internal dosimetry monitoring should be considered. (author)

  5. Skin dosimetry - radiological protection aspects of skin dosimetry

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1991-01-01

    Following a Workshop in Skin Dosimetry, a summary of the radiological protection aspects is given. Aspects discussed include routine skin monitoring and dose limits, the need for careful skin dosimetry in high accidental exposures, techniques for assessing skin dose at all relevant depths and the specification of dose quantities to be measured by personal dosemeters and the appropriate methods to be used in their calibration. (UK)

  6. Dosimetry on the radiological risks prevention in radiotherapy

    International Nuclear Information System (INIS)

    Fornet R, O. M.; Perez G, F.

    2014-08-01

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  7. Fifteenth nuclear accident dosimetry intercomparison study: August 14--22, 1978

    International Nuclear Information System (INIS)

    Sims, C.S.

    1979-05-01

    The fifteenth in the continuing series of Nuclear Accident Dosimetry Intercomparison Studies was held August 14--22, 1978 at the Oak Ridge National Laboratory. The Health Physics Research Reactor, operated in the pulse mode, served as the radiation source. Using different shielding configurations, nuclear accidents with three different neutron and gamma spectra were simulated. Participants from 19 organizations, the most in the history of the studies, exposed dosimeters set up as area monitors as well as dosimeters mounted on phantoms for personnel monitoring. Although many participants performed accurate measurements, the composite dose results, in the majority of cases, failed to meet established nuclear criticality accident dosimetry guidelines which suggest accuracies of +- 25% for neutron dose and +- 20% for gamma dose. This indicates that many participants need to improve their dosimetry systems, their analytical techniques, or both

  8. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  9. Calibration of a He accumulation fluence monitor for fast reactor dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Chikara [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    The helium accumulation fluence monitor (HAFM) has been developed for a fast reactor dosimetry. The HAFM measurement system was calibrated using He gas and He implanted samples and the measurement accuracy was confirmed to be less than 5%. Based on the preliminary irradiation test in JOYO, the measured He in the {sup 10}B type HAFM agreed well with the calculated values using the JENDL-3.2 library. (author)

  10. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  11. Analysis of SCRM experience in the area of quality assurance for retrospective EPR dosimetry technique with teeth

    International Nuclear Information System (INIS)

    Sholom, S. V.; Chumak, V.V.

    2003-01-01

    EPR dosimetry with tooth enamel is commonly accepted as one of most precise and accurate methods for retrospective dosimetry. At the same time, regularly conducted international Intercomparisons and Inter-calibrations of EPR dosimetry techniques demonstrate the significant scatter of results among laboratories operation in this area. This is mainly caused by the lack of commonly adopted unified technique which would be based on clear and efficient scheme of quality assurance. In the present work we will summarize more than ten-year experience of Scientific Center for Radiation Medicine in the area of EPR dosimetry from the point of view of quality assurance. EPR dosimetry technique with teeth, which was developed and being used in SCRM for routine dosimetry of liquidators is characterized by two-level system of quality assurance. In-house level covers all steps of the technique and allows control and minimizing of uncertainties that arise on separate steps. Extramural level provides the control of reliability and accuracy of technique in whole by means of regular participation in bi- and multi-lateral intercomparisons. Cumulative uncertainty of EPR dosimetry technique determined based on the results of 6 different intercomparisons is 21 mGy for dose below 300 and 11% for dose higher that 300 mGy. (authors)

  12. Extremity dosimetry in medical applications within Europe: an overview of doses and monitoring practices

    International Nuclear Information System (INIS)

    Donadille, Laurent; Carinou, E.; Ginjaume, M.; Jankowski, J.; Rimpler, A.; Sans Merce, M.; Vanhavere, F.

    2008-01-01

    Full text: Some activities of the EURADOS Working Group 9 (WG9) related to the radiation protection dosimetry of medical staff were funded by the European Commission in the framework of the CONRAD project, Work Package 7. The objective of WG9 was to promote and co-ordinate research activities for the assessment of occupational exposure to staff at workplaces in therapeutic and diagnostic radiology and nuclear medicine. At these workplaces, from the point of view of the individual monitoring for external radiation, the skin of the fingers is generally the limiting organ. Subgroup 1 of WG9 had as main objective the study of the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in medicine together with the difficulties of measuring a local dose which should be representative for the maximum skin dose using one single detector, makes it difficult to perform extremity dosimetry with an accuracy similar to that of whole-body one. A recent intercomparison organised by WG9 showed that some types of dosemeters significantly underestimate or overestimate skin doses. Subgroup 1 carried out a thorough literature review on extremity dosimetry issues. It covered diagnostic and therapeutic nuclear medicine and PET, interventional radiology and cardiology, and brachytherapy. It has notably pointed out the consensus about the requirement of regular extremity dose monitoring for nuclear medicine and PET, and the great difficulty of measuring extremity doses for procedures in interventional radiology and cardiology, activities for which routine extremity dose monitoring has been found to be poor. Furthermore, information on the status of extremity dosimetry in medical applications and associated monitoring practices was gathered from 7 European countries: France, Germany, Greece, Ireland, Poland, Spain and Switzerland. Interpretation of the data was not easy because of the wide range of procedures involved and also

  13. Comparison of radiation doses obtained for radiation monitoring of controlled areas with radiation doses obtained for personnel dosimetry in radiodiagnosis centers

    International Nuclear Information System (INIS)

    Lescano, Roberto; Caspani, Carlos; Universidad Nacional del Litoral, Santa Fe

    2001-01-01

    In this paper we propose to search an indicator that shows, at an objective way, the quality of the radioprotection actions. The method is about to determine doses, measured in the work area, connecting them with the workload, and finally get the dose for the center. Them we make a comparison with the personal film dosimetry data. We discuss the final results, evaluating the radioprotection conditions in daily work. (author)

  14. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  15. Report on external occupational dosimetry in Canada

    International Nuclear Information System (INIS)

    1995-12-01

    In light of the new recommendations of the ICRP in Report 60 on dose quantities and dose limits, this working group was set up to examine the implications for external dosimetry in Canada. The operational quantities proposed by the ICRU are discussed in detail with regard to their applicability in Canada. The current occupational dosimetry services available in Canada are described as well as the several performance intercomparisons that have been carried out within the country as well as internationally. Recommendations are given with respect to standards for dosimetry, including accuracy and precision. More practical advice is given on the choice of dosimeter to use for external dosimetry, frequency of monitoring, and who should be monitored. Specific advice is given on the monitoring of pregnant workers and problem of non-uniform irradiation. Accident and emergency dosimetry are dealt with briefly. Suggestions are given regarding record keeping both for employers and for the national dose registry. 48 refs., 6 tabs., 1 fig

  16. Internal dosimetry technical basis manual

    International Nuclear Information System (INIS)

    1990-01-01

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs

  17. Internal dosimetry technical basis manual

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.

  18. Practical applications of the new ICRP recommendation to external dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.

    1992-01-01

    Focussing on external dosimetry for occupational exposure the consequences of the new quantities equivalent dose (radiation weighting factor), effective dose (tissue weighting factor) and the ICRU operational quantities for individual and area dosimetry are discussed. Despite some arguments against the new quantities they should be introduced as rapidly as possible to keep international uniformity in radiation protection monitoring. It is shown that they provide a conservative estimate of the effective dose for photons and neutrons. In photon dosimetry only minor changes of the conversion factors relating operational quantities to effective dose is observed. In neutron dosimetry the conversion factors change by a factor of up to 2. It is pointed out that there is a urgent need to calculate standardized conversion factors for field quantities -operational quantities- organ and effective dose in a joint effort of ICRP and ICRU. This includes standardization of calibration methods for individual dosimetry using suitable phantoms instead of the sphere. (author)

  19. Pressure-vessel surveillance dosimetry using solid-state track recorders

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.

    1981-01-01

    In addition to radiometric and SSTR dosimetry sets, helium accumulation fluence monitors, damage monitors, and temperature monitors are being studied. The ideal dosimetry set would monitor neutron fluence, damage, and temperature with as few materials as possible in order to reduce costs and required space. It is hoped that materials such as quartz SSTR and sapphire damage monitors can be developed as multipurpose materials. Sapphire for instance, might be used as a combined fluence and damage monitor (for example, analyzed for helium accumulation, Np 237 fissions, and direct neutron damage). Continuing research will result in the optimization of dosimetry packages for use in long term surveillance of LWR Pressure Vessels

  20. Activity Of EURADOS In Environmental Solid State Dosimetry

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Duch, M. A.; Haninger, T.

    2015-01-01

    Working Group 3 (WG3) of the European Radiation Dosimetry Group (EURADOS) carries out research projects and coordinated activities to advance the scientific understanding of environmental dosimetry and especially to promote the technical development of new methods in environmental monitoring. In this field of dosimetry, the measurement of small additional doses caused by artificial radiation on top of the natural environmental radiation is a challenge. Further, WG3 stimulates the organisation of intercomparison programmes and the definition of standards and recommendations in the field of environmental radiation monitoring (ERM). WG3 has played a significant role in the harmonisation of early warning dosimetry network stations in Europe and has organised 6 EURADOS intercomparison exercises; in which 42 institutions from 19 countries have participated. Today, about 5000 stations provide real-time dose rate data to a database run by the European Commission. Within WG3 a subgroup (S1) on spectrometry system was formed in 2013. Since then, WG3 has been involved in the field of spectrometry systems used both for dosimetric and spectrometric monitoring in the environment. A remarkable result of the WG3 - S1 is that many members contributed to the new European Joint Research Project 'Metrology for radiological early warning networks in Europe' which started in 2014. A second subgroup WG3 - S2 on passive dosimetry in ERM was inaugurated in 2014. To gain an overview of the passive dosimetry practice in ERM, WG3 - S2 decided to collect information by means of a questionnaire which has been send to European dosimetry services. One of the results was the identification of some open questions, problems in ERM (for example terminology, protocol of routine dosimetry, uncertainty assessment) which require clarification for harmonisation of ERM using passive dosimeters. Another result was that there exists a need for intercomparisons. The first intercomparison for passive

  1. Modern methods of personnel dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.; Herrmann, D.; Kiesewetter, W.

    The physical properties of radiation detectors for personnel dosimetry are described and compared. The suitability of different types of dosimeters for operational and central monitoring of normal occupational exposure, for accident and catastrophe dosimetry and for background and space-flight dosimetry is discussed. The difficulties in interpreting the dosimeter reading with respect to the dose in individual body organs are discussed briefly. 430 literature citations (up to Spring 1966) are given

  2. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  3. Neutron dosimetry. Environmental monitoring in a BWR type reactor; Dosimetria de neutrones. Monitoreo ambiental en un reactor del tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tavera D, L; Camacho L, M E

    1991-01-15

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  4. Clinical dosimetry

    International Nuclear Information System (INIS)

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  5. Neutron area monitoring at storage bunkers of density/moisture gauges

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Fuste, M.J. [Grup de Fisica de les Radiacions. Universitat Autonoma de Barcelona (UAB), Edifici Cc, E-08193 Bellaterra (Spain); Amgarou, K., E-mail: khalil.amgarou@uab.ca [Grup de Fisica de les Radiacions. Universitat Autonoma de Barcelona (UAB), Edifici Cc, E-08193 Bellaterra (Spain); Garcia-Orellana, J.; Domingo, C. [Grup de Fisica de les Radiacions. Universitat Autonoma de Barcelona (UAB), Edifici Cc, E-08193 Bellaterra (Spain)

    2010-12-15

    Previous studies remarked the need of performing neutron personal dosimetry, together with gamma dosimetry, when using portable density/moisture gauges that are normally equipped with gamma and neutron sources. The convenience of our Poly-Allyl-Diglycol-Carbonate (PADC) based neutron dosimeter to perform long-term routine survey of all workers involved in the transport, maintenance and usage of these gauges was also corroborated in the past. This complete dosimetric control offers the possibility to quantify simultaneously individual neutron and gamma doses of workers operating such devices, especially in the most frequent cleaning and maintenance (shutter lubrication) operations of the gauges or in emergency situations that may lead to radiological risk of the persons involved. Another aspect to be considered, from the radioprotection point of view, is the optimization of the occupational and public exposure in the storage bunkers of the gauges. In this work, three storage bunkers, located at three different factories of the PAYMA Cotas S.A.U company, have been monitored for three months using several units of our PADC based neutron dosimeter. Special care has been taken to study also offices near the bunkers with high occupancy rates and passage zones, such as toilets and access areas. Results for all monitored points inside and around the three storage bunkers are presented. Neutron doses inside the bunkers could be relatively high depending on the specific conditions (geometry configuration, localization and shielding composition) of the considered bunker and the number of portable gauges stored.

  6. Neutron area monitoring at storage bunkers of density/moisture gauges

    International Nuclear Information System (INIS)

    Garcia-Fuste, M.J.; Amgarou, K.; Garcia-Orellana, J.; Domingo, C.

    2010-01-01

    Previous studies remarked the need of performing neutron personal dosimetry, together with gamma dosimetry, when using portable density/moisture gauges that are normally equipped with gamma and neutron sources. The convenience of our Poly-Allyl-Diglycol-Carbonate (PADC) based neutron dosimeter to perform long-term routine survey of all workers involved in the transport, maintenance and usage of these gauges was also corroborated in the past. This complete dosimetric control offers the possibility to quantify simultaneously individual neutron and gamma doses of workers operating such devices, especially in the most frequent cleaning and maintenance (shutter lubrication) operations of the gauges or in emergency situations that may lead to radiological risk of the persons involved. Another aspect to be considered, from the radioprotection point of view, is the optimization of the occupational and public exposure in the storage bunkers of the gauges. In this work, three storage bunkers, located at three different factories of the PAYMA Cotas S.A.U company, have been monitored for three months using several units of our PADC based neutron dosimeter. Special care has been taken to study also offices near the bunkers with high occupancy rates and passage zones, such as toilets and access areas. Results for all monitored points inside and around the three storage bunkers are presented. Neutron doses inside the bunkers could be relatively high depending on the specific conditions (geometry configuration, localization and shielding composition) of the considered bunker and the number of portable gauges stored.

  7. EURADOS intercomparison 2006 to harmonise European early warning dosimetry systems

    International Nuclear Information System (INIS)

    Dombrowski, H.; Neumaier, S.; Thompson, I. M. G.; Wissmann, F.

    2009-01-01

    In 2006, the European Radiation Dosimetry (EURADOS) Working Group on Environmental Radiation Monitoring (WG3) organised a third European intercomparison of dosimetry systems operated in national early warning networks. Similar to the intercomparisons in 1999 and 2002, the main aim of this exercise was to support the process of harmonisation of area monitoring in Europe by providing the network operators with basic information on the calibration and performance of their dosimetry systems. In order to characterise these systems, their following basic parameters were investigated: the response to terrestrial and cosmic radiation, the detectors' inherent background, the response at low dose rates, the energy dependence of the response as well as the sensitivity of the detector systems to small changes of the dose rate in a natural environmental radiation field. In the 2006 EURADOS intercomparison, scientists from seven countries participated to study the characteristics of 11 detector systems. All results are presented in terms of the operational quantity ambient dose equivalent, H * (10). The advent of this quantity has caused the development of new detector systems for area monitoring. Some of these new systems participated in a EURADOS intercomparison for the first time. The results are consistently presented together with uncertainties so that statistical effects can be distinguished from real detector features, which improves the interpretation of the results. By using the results of this intercomparison, some detectors were re-calibrated. The achievable improvements concerning harmonisation in dose-rate measurements in the natural environment are discussed. (authors)

  8. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed

  9. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  10. Current internal-dosimetry practices at US Department of Energy facilities

    International Nuclear Information System (INIS)

    Traub, R.J.; Murphy, B.L.; Selby, J.M.; Vallario, E.J.

    1985-04-01

    The internal dosimetry practice at DOE facilities were characterized. The purpose was to determine the size of the facilities' internal dosimetry programs, the uniformity of the programs among the facilities, and the areas of greatest concern to health physicists in providing and reporting accurate estimates of internal radiation dose and in meeting proposed changes in internal dosimetry. The differences among the internal-dosimetry programs are related to the radioelements in use at each facility and, to some extent, the number of workers at each facility. The differences include different frequencies in the use of quality control samples, different minimum detection levels, different methods of recording radionuclides, different amounts of data recorded in the permanent record, and apparent differences in modeling the metabolism of radionuclides within the body. Recommendations for improving internal-dosimetry practices include studying the relationship between air-monitoring/survey readings and bioassay data, establishing uniform methods for recording bioassay results, developing more sensitive direct-bioassay procedures, establishing a mechanism for sharing information on internal-dosimetry procedures among DOE facilities, and developing mathematical models and interactive computer codes that can help quantify the uptake of radioactive materials and predict their distribution in the body. 19 refs., 8 tabs

  11. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  12. Individual monitoring of medical staff working in interventional radiology in Switzerland using double dosimetry

    International Nuclear Information System (INIS)

    Damet, J.; Bailat, C.; Bize, P.; Buchillier, Th.; Tosic, M.; Verdun, F.R.; Baechler, S.

    2011-01-01

    Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

  13. Reference dosimetry of proton pencil beams based on dose-area product: a proof of concept.

    Science.gov (United States)

    Gomà, Carles; Safai, Sairos; Vörös, Sándor

    2017-06-21

    This paper describes a novel approach to the reference dosimetry of proton pencil beams based on dose-area product ([Formula: see text]). It depicts the calibration of a large-diameter plane-parallel ionization chamber in terms of dose-area product in a 60 Co beam, the Monte Carlo calculation of beam quality correction factors-in terms of dose-area product-in proton beams, the Monte Carlo calculation of nuclear halo correction factors, and the experimental determination of [Formula: see text] of a single proton pencil beam. This new approach to reference dosimetry proves to be feasible, as it yields [Formula: see text] values in agreement with the standard and well-established approach of determining the absorbed dose to water at the centre of a broad homogeneous field generated by the superposition of regularly-spaced proton pencil beams.

  14. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  15. Non-conventional personal dosimetry techniques

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1984-01-01

    Established dosimetry has achieved a high standard in personnel monitoring. This applies particularly to photon dosimetry. Nevertheless, even in photon dosimetry, improvements and changes are being made. The reason may be technological progress, or the introduction of new tasks on the basis of the recommendations of international bodies (e.g. the new ICRU measurement unit) of national legislation. Since we are restricting ourselves here to technical trends the author would like to draw attention to various activities of current interest, e.g. the computation of receptor-related conversion coefficients from personal dose to organ or body doses, taking into account the conditions of exposure with respect to differential energy and angular distribution of the radiation field. Realistic data on exposure geometry are taken from work place analyses. Furthermore, the data banks of central personal dosimetry services are subject to statistical evaluation and radiation protection trend analysis. Technological progress and developments are considered from the point of view of personal dosimetry, partial body or extremity dosimetry and accidental dosimetry

  16. Field dosimetry on sterilization area of medical-hospitable materials

    International Nuclear Information System (INIS)

    Mariano, C.S.T.P.; Campos, L.L.

    1992-01-01

    The calcium sulfate doped with dysprosium, used in high dose dosimetry by electron paramagnetic resonance (EPR), is studied on field dosimetry for medical-hospitable materials sterilization. The calibration curves of EPR signal in function of absorbed dose in air and the thermal decay of EPR signal at room temperature are also presented. (C.G.C)

  17. Developments in physical dosimetry and radiation protection; Entwicklungen in der physikalischen Dosimetrie im Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Fiebich, Martin [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-07-01

    In the frame of physical dosimetry new dose units have been defined: the depth personal dose (equivalent dose in 10 mm depth) and the surface personal dose (equivalent dose in 0.07 mm depth). Physical dosimetry is applied for the determination of occupational radiation exposure, the radiation protected area control, the estimation of radiation exposure of patients during radiotherapy, for quality assurance and in research projects and optimization challenges. Developments have appeared with respect to punctual measuring chambers, eye lens dosimetry, OSL (optically stimulated luminescence) dosimetry, real-time dosimetry and Monte Carlo methods. New detection limits of about 1 micro Gy were reached.

  18. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  19. Recent progress in application of JAERI alanine/ESR dosimetry system

    International Nuclear Information System (INIS)

    Kojima, T.

    1995-01-01

    Feasibility studies of application of JAERI alanine/ESR dosimetry system were performed on radiotherapy level dosimetry, low dose-rate dosimetry for residual life estimation of cable insulators used in nuclear power facilities, and dose monitoring for electron processing. (author)

  20. Interlaboratory niobium dosimetry comparison

    International Nuclear Information System (INIS)

    Wille, P.

    1980-01-01

    For an interlaboratory comparison of neutron dosimetry using niobium the 93 sup(m)Nb activities of irradiated niobium monitors were measured. This work was performed to compare the applied techniques of dosimetry with Nb in different laboratories. The niobium monitors were irradiated in the fast breeder EBRII, USA and the BR2, Belgium. The monitors were dissolved and several samples were prepared. Their niobium contents were determined by the 94 Nb-count rates. since the original specific count rate was known. The KX radiations of the 93 sup(m)Nb of the samples and of a calibrated Nb-foil were compared. This foil was measured by PTB, Braunschweig and CBNM, Geel, which we additionally compared with the KX radiation of 88 Sr produced by a thin 88 Y source from a 88 Y-standard solution (PTB). (orig.) [de

  1. Trends in gel dosimetry: Preliminary bibliometric overview of active growth areas, research trends and hot topics from Gore’s 1984 paper onwards

    International Nuclear Information System (INIS)

    Baldock, C

    2017-01-01

    John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and including 2016. Themes and trends of the gel dosimetry research field were bibliometrically explored by way of co-occurrence term maps using the titles and abstracts text corpora from the Web of Science database for all relevant papers from 1984 to 2016. Visualisation of similarities was used by way of the VOSviewer visualisation tool to generate cluster maps of gel dosimetry knowledge domains and the associated citation impact of topics within the domains. Heat maps were then generated to assist in the understanding of active growth areas, research trends, and emerging and hot topics in gel dosimetry. (paper)

  2. Hanford internal dosimetry program manual

    International Nuclear Information System (INIS)

    Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.; Aldridge, T.L.

    1989-10-01

    This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs

  3. Dosimetry and shielding

    International Nuclear Information System (INIS)

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  4. User's guide for survey-meter- and film-badge-dosimetry data bases

    International Nuclear Information System (INIS)

    Phillips, W.G.; Sherman, S.; Young, R.

    1981-05-01

    This manual describes the data storage and retrieval system designed by Environmental Monitoring Systems Laboratory Las Vegas (EMSL-LV) for radiation exposure data recorded in offsite areas during and after nuclear weapons tests conducted at the Nevada Test Site in the 1950's and early 1960's. Referred to hereinafter as the EMSL-LV system, this system contains two distinct subsets of offsite radiological measurements collected during early nuclear atmospheric tests at the Nevada Test Site. The purpose of the manual is to present the methods for using the EMSL-LV system to examine all or any portion of either data subset. The two distinct subsets which comprise the EMSL-LV system are survey meter data and film badge dosimetry data. The survey meter data consist of readings obtained from portable radiation monitoring instruments used around the Nevada Test Site during the 1950's and early 1960's to measure radiation exposure rates resulting from the nuclear testing program. The dosimetry data consist of measurements of integrated radiation exposure made with film badge type dosimeters in areas surrounding the Nevada Test Site

  5. An instrument to perform automated quality assurance and patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Chapple, C.-L.; Faulkner, K.

    1992-01-01

    A computerised method of automatically monitoring tube and generator parameters to perform on-line quality assurance and patient dosimetry has been developed. A microcomputer has been interfaced to a microprocessor controlled X ray generator and dose-area product meter. The instrument prompts the operator to enter details of the examination and projection before an examination is made. The field size and dose-area product are monitored by the instrument. These data, together with information on the tube potential are used to deduce the patient entrance dose and energy imparted. Organ doses are estimated using normalised organ dose data. The accuracy and reproducibility of the instrument were investigated. Doses measured in a Rando phantom were compared with calculations made by the instrument. The instrument will compare various measured quality assurance parameters against their nominal values. The implications of this instrument for both patient dosimetry studies and effective continuous quality assurance are discussed. (author)

  6. Radiation area monitoring by wireless-communicating area monitor with surveillance camera

    International Nuclear Information System (INIS)

    Shimura, Mitsuo; Kobayashi, Hiromitsu; Kitahara, Hideki; Kobayashi, Hironobu; Okamoto, Shinji

    2004-01-01

    Aiming at a dose reduction and a work efficiency improvement for nuclear power plants that have high dose regions, we have developed our system of wireless-communicating Area Monitor with Surveillance Camera, and have performed an on-site test. Now we are implementing this Area Monitor with Surveillance Camera for a use as a TV camera in the controlled-area, which enables a personal computer to simultaneously display two or more dose values and site live images on the screen. For the radiation detector of this Area Monitor System, our wireless-communicating dosimeter is utilized. Image data are transmitted via a wireless Local Area Network (LAN). As a test result, image transmission of a maximum of 20 frames per second has been realized, which shows that this concept is a practical application. Remote-site monitoring also has been realized from an office desk located within the non-controlled area, adopting a Japan's wireless phone system, PHS (Personal Handy Phone) for the transmission interface. (author)

  7. Technical requirements for implementation of an individual monitoring service for evaluation of operational quantity HP(10) using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Francisco, Adelaide Benedita Armando

    2016-01-01

    This work aims to establish technical requirements for the development of a TLDs system for the assessment of operational quantity H P (10), in order to implement an external individual monitoring service in countries who do not have. This allows a better understanding of the technic and the thermoluminescent dosimetry system, thus contributing to identify the technical criteria to be followed by a dosimetry laboratory and evaluation of the dosimetric system performance. For this, the review of the specific literature of the dosimetry field was conducted and later the type and performance tests that must be followed by a dosimetric system were reproduced in practice. In additional was made a analysis of internationals standards norms and the technical regulation used in Brazil, to define the essentials type testes to a dosimetric system. To check the performance of a dosimetry system, a performance analysis of the Brazilian TLDs system was carried out over the past 6 years using the trumpet curve, where it was observed that most of TLDs system, in this review period, were approved and have excellent performance. The technical requirements for the development of a thermoluminescent dosimetry system ensure that the system provides technically reliable results and allow demonstration of compliance with the standard criteria established by national and international standards, and the implementation of the dosimetry system, is verified the compliance of the annual doses limits set for occupationally exposed. (author)

  8. Pulse monitor for upper extremities dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Cledison de Jesus, Cunha; Divanizia do Nascimento, Souza

    2006-01-01

    In the manipulation of radioactive materials in Nuclear Medicine service the body parts of workers that are more displayed to the ionizing radiation are hands, underarm and arm. Therefore is necessary to developing personal dosimeters to monitoring of easy reproduction and low cost with purpose to determine the doses level radiation received by the worker in these extremities. However thermoluminescent dosimeters do not provide an instantaneous exposure reading, they are suitable for personal dosimetry because of their following advantages: wide useful dose range, small physical size and no need for high voltage or cables, i.e. stand alone character. The aim of this work is to investigation of a new pulse monitor, that has been developing with thermoluminescent detectors of CaSO 4 :Dy (TLD) using a small plate of acrylic, perforated cardboard to deposit the TLD. This set was involved in plastic to protect from humidity and other harmful ambient factors; moreover, a bracelet was inserted, adaptable for any worker. During the preparation of the personal dosimeters to monitor exposure it was necessary to verify their effectiveness to use by workers in a nuclear medicine service. The monitors have been submitted to procedures of performance evaluations by several tests: badges homogeneity, reproducibility, linearity, low detection limit, auto-irradiation, dosimeters stability, verification of the residual T.L. signal, visible light effect on dosimeters, energetic and angular dependence and TLD answer by influence of a simulator during radiation. Was possible to verify the efficiency of such upper extremities dosimeters and were obtained satisfactory results within of the limits demanded in the described tests above to this type of personal dosimeters. (authors)

  9. Technical basis for internal dosimetry at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78 refs., 35 figs., 115 tabs.

  10. Technical basis for internal dosimetry at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1989-04-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64 refs., 42 figs., 118 tabs.

  11. Technical basis for internal dosimetry at Hanford

    International Nuclear Information System (INIS)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ( 58 Co, 60 Co, 54 Mn, and 59 Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78 refs., 35 figs., 115 tabs

  12. Technical basis for internal dosimetry at Hanford

    International Nuclear Information System (INIS)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1989-04-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ( 58 Co, 60 Co, 54 Mn, and 59 Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64 refs., 42 figs., 118 tabs

  13. Development of web monitoring radiation area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon Jin; Lee, Jun Hee; Namkoong, Phil; Lee, Dong Hoon; Lee, Su Hong; Lee, Gun Bae

    2005-01-01

    Recently the increasing number of radioisotope industry and nuclear facility have ever raised the possibility of radiation safety accident. As such a result, radioisotope companies and nuclear facility operators have become to be much interested in radiation area monitoring for efficient radiation protection. At present, almost of the radiation area monitors which are imported products are outdated in aspect of their functions. Diversification of the monitoring work is urgently demanding additional functions to be added. Thus we have developed new-type digital area monitor which enables remote web monitoring with image and radiation dose rate value at distant places through using internet, the latest IT technology, and radiation measurement technology

  14. Type test of the Rados MTS-N thermoluminescent dosimetry system for individual monitoring of whole body photons in HP (10)

    International Nuclear Information System (INIS)

    Ferreira, M.S.; Silva, E.R. da; Maurício, C.L.P.

    2017-01-01

    The Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ), uses an automatic thermoluminescent dosimetry (TL) system for evaluation of whole body for photons with individual monitors RADOS MTS-N, with TLF detector of LiF: Mg, Ti. The objective of this work was to characterize this system for the evaluation of H P (10) operating magnitude. The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. Performance tests were done for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence and fading. The acceptance requirements used to test system performance have been drawn from national and international documents. The results obtained prove that the system can be used to measure the occupational dose of photons in H P (10)

  15. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  16. Overview of environmental radiological monitoring program of Institute of Radiation Protection And Dosimetry - IRD

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Sarah Barreto Oliveira de Christo; Peres, Sueli da Silva, E-mail: suelip@ird.gov.br, E-mail: sarah.barreto1@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radioproteção

    2017-07-01

    As a branch of the Brazilian Nuclear Energy Commission (CNEN), the Institute of Radiation Protection and Dosimetry (IRD) performs extensive activities in the fields of radiation protection, metrology, and dosimetry, as well as specific education, onto a wide operational scope that includes the technical support to national regulatory authorities in the licensing process for nationwide nuclear and radioactive facilities. IRD has several laboratories where are performed radiometric and radiochemical analyses and others radioactivity evaluation procedures in different types of samples obtained in the inspection activities, production of radioactivity metrological standards and reference material by National Laboratory of Metrology of Ionizing Radiation (LMNRI), besides others research activities. In this laboratories can be used sealed or unsealed radioactive sources and radiation-producing devices and are classified with radioactive installations in accordance to national regulations. This way, radioactive liquid effluents can be eventually produced and released into the environment in the course of such activities and an effluent monitoring program to control and reduce the releases to environment is carried out. Additionally, IRD maintains the Radioactive Waste Management Program and Environmental Radiological Monitoring Program (ERMP) in accordance to national regulations requirements. The primary focus of ERMP comprises the validation of the dose prognostics for the public members due to effluents discharge and the provision of consistent projections of the radiation levels at the monitoring sites. In this study, a long term ERMP data survey is discussed, spanning the last thirteen years of activities. On the basis of such discussions and prognostics, it could be observed that the radiological environmental radiological impact due to operation of IRD installations is negligible. (author)

  17. Overview of environmental radiological monitoring program of Institute of Radiation Protection And Dosimetry - IRD

    International Nuclear Information System (INIS)

    Gomes, Sarah Barreto Oliveira de Christo; Peres, Sueli da Silva

    2017-01-01

    As a branch of the Brazilian Nuclear Energy Commission (CNEN), the Institute of Radiation Protection and Dosimetry (IRD) performs extensive activities in the fields of radiation protection, metrology, and dosimetry, as well as specific education, onto a wide operational scope that includes the technical support to national regulatory authorities in the licensing process for nationwide nuclear and radioactive facilities. IRD has several laboratories where are performed radiometric and radiochemical analyses and others radioactivity evaluation procedures in different types of samples obtained in the inspection activities, production of radioactivity metrological standards and reference material by National Laboratory of Metrology of Ionizing Radiation (LMNRI), besides others research activities. In this laboratories can be used sealed or unsealed radioactive sources and radiation-producing devices and are classified with radioactive installations in accordance to national regulations. This way, radioactive liquid effluents can be eventually produced and released into the environment in the course of such activities and an effluent monitoring program to control and reduce the releases to environment is carried out. Additionally, IRD maintains the Radioactive Waste Management Program and Environmental Radiological Monitoring Program (ERMP) in accordance to national regulations requirements. The primary focus of ERMP comprises the validation of the dose prognostics for the public members due to effluents discharge and the provision of consistent projections of the radiation levels at the monitoring sites. In this study, a long term ERMP data survey is discussed, spanning the last thirteen years of activities. On the basis of such discussions and prognostics, it could be observed that the radiological environmental radiological impact due to operation of IRD installations is negligible. (author)

  18. Teledosimetry: Personal and Area Dosimetry Control in order to evaluate the risk in real time

    International Nuclear Information System (INIS)

    Galan Montenegro, P.; Macias Jaen, J.; Bodineau Gil, C.; Sanchez Hidalgo, M.

    2004-01-01

    Telemedicine is now an essential part of Health care and so, in addition to the scientific programme in the Carlos Haya Hospital in Malaga, Physics Department is involved into a process of change about the vision as a new Health Centre of XXI Century: Knowledge Hospital, by digital architecture and digitally integrated in its world. The Integrating the Health care Enterprise is the model used in order to get a big grade of relationship between medical images and information system. This change must be done in colaboration between some Departments of our centre, because it is a multidisciplinary task. It is understood that Teledosimetry can be considered as an important part of Telemedicine in the Radiological Protection field for workers and general public. In order to get this objective, the first step since 2000 it has been to prepare the internal hospital network with personal dosimetry information. From here workers in our hospital can obtain their dosimetry information data in more than 300 computers and since 2003, from home too. For access, each one of all have got an user identification and a password and so it can be guaranteed the privacy. We transform dose data reported by CND (Dosimetry National Center) in a big and visible database in PHP4 and Javascript format. This process is marked of problems about all due to the big manipulated information. Our intention is to make a better and friendly control, customisable and in real-time of the information dosimetry by a modular monitoring system of electronic dosimeters by the web. These radiation detectors would be located in representatives places. (Author)

  19. Teledosimetry: Personal and Area Dosimetry Control in order to evaluate the risk in real time

    Energy Technology Data Exchange (ETDEWEB)

    Galan Montenegro, P.; Macias Jaen, J.; Bodineau Gil, C.; Sanchez Hidalgo, M.

    2004-07-01

    Telemedicine is now an essential part of Health care and so, in addition to the scientific programme in the Carlos Haya Hospital in Malaga, Physics Department is involved into a process of change about the vision as a new Health Centre of XXI Century: Knowledge Hospital, by digital architecture and digitally integrated in its world. The Integrating the Health care Enterprise is the model used in order to get a big grade of relationship between medical images and information system. This change must be done in colaboration between some Departments of our centre, because it is a multidisciplinary task. It is understood that Teledosimetry can be considered as an important part of Telemedicine in the Radiological Protection field for workers and general public. In order to get this objective, the first step since 2000 it has been to prepare the internal hospital network with personal dosimetry information. From here workers in our hospital can obtain their dosimetry information data in more than 300 computers and since 2003, from home too. For access, each one of all have got an user identification and a password and so it can be guaranteed the privacy. We transform dose data reported by CND (Dosimetry National Center) in a big and visible database in PHP4 and Javascript format. This process is marked of problems about all due to the big manipulated information. Our intention is to make a better and friendly control, customisable and in real-time of the information dosimetry by a modular monitoring system of electronic dosimeters by the web. These radiation detectors would be located in representatives places. (Author)

  20. Field monitoring versus individual miner dosimetry of radon daughter products in mines.

    Science.gov (United States)

    Domański, T; Kluszczyński, D; Olszewski, J; Chruscielewski, W

    1989-01-01

    The paper presents the results realised simultaneously by two different and independent systems of measurement of an assessment of miners' exposure to radon daughter products which naturally occur in the air of mines. The first one, called the Air Sampling System (ASS), was based on the field monitoring of radon progeny in air, the second one, called the Individual Dosimetry System (IDS), was based on the individual dosimeters worn by miners. Experimental comparison of these two systems has been conducted for six years in eleven Polish underground metal-ore mines. This study reveals that no correlation exists between the concentration and annual miners' exposures evaluated by the ASS and IDS. The ratio ASS/IDS for mine population varies from 11.0 to 0.14 in respect of annual concentration means, and in respect to annual exposures, this ratio varies from 4.5 to 0.14. The conclusion to be drawn from six years' observation and comparison of both systems is that correct and true evaluation of miners' exposure to radon progeny can be made only by the use of the Individual Dosimetry System, since the Air Sampling System is too sensitive and too dependent on the Strategy of sampling and its radiation.

  1. Comparisons between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting

    International Nuclear Information System (INIS)

    Kiuru, A.; Kahilainen, J.; Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    A new electronic direct ion storage (DIS) dosemeter allows accumulated personal dose equivalent H p (d) at depths of 10 mm and 0.07 mm to be monitored in a few seconds by inserting the dosemeter into a local reader without deleting the accumulated dose. The DIS system meets general requirements on individual monitoring of hospital personnel using ionising radiation. It differs greatly from off-line thermoluminescence dosimetry systems and offers many additional benefits. The non-volatile reading takes only 5 s, is taken as often as needed, and the data are collected into a dose database, where background radiation is subtracted. Individual personnel doses are reported in Intranet as well as on the Internet at regular intervals to the National Regulatory Authorities. (author)

  2. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  3. To monitor or not to monitor?: editorial

    International Nuclear Information System (INIS)

    Johns, T.F.

    1988-01-01

    After a brief discussion about results for occupational exposure in New Zealand and the UK, a short editorial raises a number of questions about personal dosimetry practice. These questions include whether the right people are being monitored and whether less attention should be paid to the monitoring of certain groups of workers who are occupationally exposed to external beta/gamma radiation, and more to the monitoring of workers or members of the general public who are exposed to higher doses from radon daughters, so as to focus attention on the areas where the largest savings in collective dose could be achieved. (U.K.)

  4. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual DosimetryWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MAY/JUNE will be available from their usual dispatchers on Tuesday 2 May.Please have your films changed before the 12 May.The colour of the dosimeter valid in is MAY/JUNE is YELLOW.Individual Dosimetry Service will be closed on Friday 28 April.

  5. Dosimetry for photo-coagulation by the use of autofluorescence

    Science.gov (United States)

    Brodzinski, T.

    1989-01-01

    A basic problem when using lasers in medicine is that of dosimetry. The definition of the terms dose, effective value etc. will be dealt with in Chapter 2. This chapter is intended to give an insight into the problems of basic dosimetry and its technical realization within the field of photocoagulation, an established method used to treat the retina, or some skin diseases. Until now the coagulation process was assessed to be completed when the irradiated area became blanched. However in terms of dosimetry, it must be possible to predict or at least to monitor the biological effect using well-defined parameters for the laser or in achieving an objective measure for a feedback loop. In the case of coagulation, a prediction in this form is not possible. There are two ways of pro- ceeding further see Fig. 1. One can either determine the physical effect, i.e. temperature, by some kind of sensors, or even better, use some biological effect as a direct measure of the effective dose applied.

  6. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  7. Hanford Internal Dosimetry Project manual. Revision 1

    International Nuclear Information System (INIS)

    Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.; Long, M.P.

    1994-07-01

    This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, and guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program

  8. Hanford Internal Dosimetry Project manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.; Long, M.P.

    1994-07-01

    This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, and guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.

  9. Sandia National Laboratories Internal Dosimetry Technical Basis Manual (Rev 4)

    Energy Technology Data Exchange (ETDEWEB)

    Goke, Sarah Hayes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Elliott, Nathan Ryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program. The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.

  10. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  11. Classical microdosimetry in radiation protection dosimetry and monitoring

    International Nuclear Information System (INIS)

    Waker, A.J.; Schrewe, U.; Burmeister, J.; Dubeau, J.; Surette, R.A.

    2002-01-01

    Classical microdosimetry concerns the measurement and analysis of the spectrum of radiation energy deposition events in simulated microscopic tissue-equivalent sites. Over the past three decades, classical microdosimetry has been extensively applied for the direct measurement of dosimetric quantities, such as the ambient dose equivalent, and for the spectroscopic properties of tissue-equivalent proportional counters that have led to the methods of mixed-field analysis and particle identification. This paper reviews some of the special applications of classical microdosimetry such as the determination of kerma coefficients, differential dosimetry and aviation dosimetry. Also reviewed are some of the technological innovations related to the application of microdosimetry in operational health physics and in particular the development of multi-element proportional counters and detectors based on gas microstrip technology. (author)

  12. Application of numerical analysis methods to thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs

  13. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  14. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  15. External audit in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Thwaites, D.I.; Western General Hospital, Edinburgh

    1996-01-01

    Quality audit forms an essential part of any comprehensive quality assurance programme. This is true in radiotherapy generally and in specific areas such as radiotherapy dosimetry. Quality audit can independently test the effectiveness of the quality system and in so doing can identify problem areas and minimize their possible consequences. Some general points concerning quality audit applied to radiotherapy are followed by specific discussion of its practical role in radiotherapy dosimetry, following its evolution from dosimetric intercomparison exercises to routine measurement-based on-going audit in the various developing audit networks both in the UK and internationally. Specific examples of methods and results are given from some of these, including the Scottish+ audit group. Quality audit in radiotherapy dosimetry is now well proven and participation by individual centres is strongly recommended. Similar audit approaches are to be encouraged in other areas of the radiotherapy process. (author)

  16. Recent developments in detectors/phantoms for dosimetry, X-ray quality assurance and imaging

    International Nuclear Information System (INIS)

    Sankaran, A.

    2009-01-01

    During the past years, many new developments have taken place in detectors/phantoms for high energy photon and electron dosimetry (for radiotherapy), protection monitoring, X-ray quality assurance and X-ray imaging (for radiodiagnosis). A variety of detectors and systems, quality assurance (QA) gadgets and special phantoms have been developed for diverse applications. This paper discusses the important developments with some of which the author was actively associated in the past. For dosimetry and QA of 60 Co and high energy X-ray units, state-of-the-art radiation field analyzers, matrix ion chambers, MOSFET devices and Gafchromic films are described. OSL detectors find wide use in radiotherapy dosimetry and provide a good alternative for personnel monitoring. New systems introduced for QA/dosimetry of X-ray units and CT scanners include: multi-function instruments for simultaneous measurement of kVp, dose, time, X-ray waveform and HVT on diagnostic X-ray units; pencil chamber with head and body phantoms for CTDI check on CT scanners. Examples of phantoms used for dosimetry and imaging are given. Advancements in the field of diagnostic X-ray imaging (with applications in portal imaging/dosimetry of megavoltage X-ray units) have led to emergence of: film-replacement systems employing CCD-scintillator arrays, computed radiography (CR) using storage phosphor plate; digital radiography (DR), using a pixel-matrix of amorphous selenium, or amorphous silicon diode coupled to scintillator. All these provide (a) in radiotherapy, accurate dose delivery to tumour, saving the surrounding tissues and (b) in radiodiagnosis, superior image quality with low patient exposure. Lastly, iPODs and flash drives are utilized for storage of gigabyte-size images encountered in medical and allied fields. Although oriented towards medical applications, some of these have been of great utility in other fields, such as industrial radiography as well as a host of other research areas. (author)

  17. Group: radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.

    1990-01-01

    The main activities of the radiation dosimetry group is described, including the calibration of instruments, sources and radioactive solutions and the determination of neutron flux; development, production and market dosimetric materials; development radiation sensor make the control of radiation dose received by IPEN workers; development new techniques for monitoring, etc. (C.G.C.)

  18. In vivo dosimetry in radiation therapy in Sweden; In vivo-dosimetri inom straalbehandling i Sverige

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Jacob; Blomquist, Michael (Norrlands universitetssjukhus, Umeaa (Sweden))

    2010-07-15

    A prerequisite for achieving high radiation safety for patients receiving external beam radiation therapy is that the hospitals have a quality assurance program. The program should include include monitoring of the radiation dose given to the patient. Control measurements are performed both at the system level and at the individual level. Control measurement is normally performed using in vivo dosimetry, e.g. a method to measure the radiation dose at the individual level during the actual radiation treatment time. In vivo dosimetry has proven to be an important tool to detect and prevent serious errors in patient treatment. The purpose of this research project was to identify the extent to which vivo dosimetry is used and the methods available for this at Swedish radiation therapy clinics. The authority also wanted to get an overall picture of how hospitals manage results of in vivo dosimetry, and how clinics control radiation dose when using modern treatment techniques. The report reflects the situation in Swedish radiotherapy clinics 2007. The report shows that all hospitals use some form of in vivo dosimetry. The instruments used are mainly diodes and termoluminiscence dosimeters

  19. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  20. Dosimetry on the radiological risks prevention in radiotherapy; La dosimetria en la prevencion de riesgos radiologicos en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Fornet R, O. M.; Perez G, F., E-mail: nuclear2@citmahlg.holguin.inf.cu [Delegacion Territorial del CITMA, Peralta 16 esq. P. Feria, Rpto. Peralta, 80400 Holguin (Cuba)

    2014-08-15

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  1. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  2. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    International Nuclear Information System (INIS)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L.

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years

  3. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1981

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.; Hopper, J.L. (comps.)

    1982-08-01

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry and sampling methods, analytical procedures, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation. The monitoring networks detected no radioactivity in the various media which could be attributed to US nuclear testing. Small amounts of fission products were detected in air samples as a result of the People's Republic of China nuclear test and atmospheric krypton-85 increased, following the trend beginning in 1960, due to increased use of nuclear technology. Strontium-90 in milk and cesium-137 in meat samples continued the slow decline as observed for the last several years.

  4. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  5. Integration of external and internal dosimetry in Switzerland

    International Nuclear Information System (INIS)

    Frei, D.; Wernli, C.; Baechler, S.; Fischer, G.; Jossen, H.; Leupin, A.; Lortscher, Y.; Mini, R.; Otto, T.; Schuh, R.; Weidmann, U.

    2007-01-01

    Individual monitoring regulations in Switzerland are based on the ICRP60 recommendations. The annual limit of 20 mSv for the effective dose applies to the sum of external and internal radiation. External radiation is monitored monthly or quarterly with TLD, DIS or CR-39 dosemeters by 10 approved external dosimetry services and reported as H p (10) and H p (0.07). Internal monitoring is done in two steps. At the workplace, simple screening measurements are done frequently in order to recognise a possible incorporation. If a nuclide dependent activity threshold is exceeded then one of the seven approved dosimetry services for internal radiation does an incorporation measurement to assess the committed effective dose E 50 . The dosimetry services report all the measured or assessed dose values to the employer and to the National Dose Registry. The employer records the annually accumulated dose values into the individual dose certificate of the occupationally exposed person, both the external dose H p (10) and the internal dose E 50 as well as the total effective dose E = H p (10) + E 50 . Based on the national dose registry an annual report on the dosimetry in Switzerland is published which contains the statistics for the total effective dose, as well as separate statistics for external and internal exposure. (authors)

  6. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  7. Quality assurance in personal dosimetry of external radiation: present situation and future needs

    International Nuclear Information System (INIS)

    Ma, N.

    2006-01-01

    Whole body personal dosimetry is well established for the individual monitoring of radiation workers. High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The mandate has been given to the Personal Dosimetry, (secondary standard dosimetry laboratories) S.S.D.L., (Malaysian institute for nuclear energy research) M.I.N.T. to assure the individual monitoring for radiation workers in Malaysia. In 2005, the S.S.D.L;-M.I.N.T. supply, process and read out of personal dosemeters of nearly 13,000 dosimeters monthly, whereby. 12,000 are films and 1,000 are T.L.D.s. The objective of individual monitoring is not limited to the measurement of doses delivered to individuals, but it should demonstrate that limits of exposure have not been exceeded and that working conditions have not unexpectedly deteriorated. Dosimetry measurements are an important component of radiation protection programs and must be of high quality. The exposure of workers to radiation must be controlled and monitored in order to comply with regulatory requirements. S.S.D.L.-M.I.N.T; demonstrates that its performance is at an acceptable level by implementing overall system performance, as evidenced by the ISO 9001 certification of the Personal Dosimetry Service in 2002 and ISO/I.E.C. 17025 accreditation to the calibration laboratory in 2004. The certification and accreditation processes achieved the goal by formalizing the recognition of satisfactory performance, and providing evidence of this performance. Overall performances are assessed, personnel operating the system will be trained and are well qualified and all actions will be documented. The paper describes the overview of the Q.M.S. carried out at the S.S. D.L.-M.I.N.T.. During the implementation of Q.M.S. a few areas has been identified for future consideration. These include performance specification and type testing of dosemeters, which provide a

  8. The work programme of EURADOS on internal and external dosimetry.

    Science.gov (United States)

    Rühm, W; Bottollier-Depois, J F; Gilvin, P; Harrison, R; Knežević, Ž; Lopez, M A; Tanner, R; Vargas, A; Woda, C

    2018-01-01

    Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .

  9. Role of secondary standard dosimetry laboratory in radiation protection program

    International Nuclear Information System (INIS)

    Rahman, Sohaila; Ali, Noriah Mohd.

    2008-01-01

    Full text: The radiation dosimetry program is an important element of operational radiation protection. Dosimetry data enable workers and radiation protection professionals to evaluate and control work practices to eliminate unnecessary exposure to ionizing radiation. The usefulness of the data produced however depends on its quality and traceability. The emphasis of the global dosimetry program is focused through the IAEA/WHO network of secondary standard dosimetry laboratories (SSDLs), which aims for the determination of SI quantities through proper traceable calibration of radiation protection equipment. The responsibility of SSDL-NUCLEAR MALAYSIA to guarantee a reliable dosimetry service, which is traceable to international standards, is elucidated. It acts as the basis for harmonized occupational radiation monitoring in Malaysia.

  10. PeDaB - the personal dosimetry database at the research centre Juelich

    International Nuclear Information System (INIS)

    Geisse, C.; Hill, P.; Paschke, M.; Hille, R.; Schlaeger, M.

    1998-01-01

    In May, 1997 the mainframe based registration, processing and archiving of personal monitoring data at the research centre Juelich (FZJ) was transferred to a client server system. A complex database application was developed. The client user interface is a Windows based Microsoft ACCESS application which is connected to an ORACLE database via ODBC and TCP/IP. The conversion covered all areas of personal dosimetry including internal and external exposition as well as administrative areas. A higher degree of flexibility, data security and integrity was achieved. (orig.) [de

  11. Experimental facilities for calibrations at the dosimetry facility of group 6.5 'Neutron dosimetry' at the Physikalisch-Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Strzelczyk, H.

    1986-07-01

    The mechanical and electrical layout of the ''Dosimetriemessplatz'', a low scattering target area at the accelerator facility is described. Monoenergetic neutrons are generated at the irradiation facility for the research on neutron detectors and dosimeters for radiation protection. The report is aimed to inform dosimetry in particular for those guest's coming from other laboratories. For that purpose a detailed description is given of the mechanical construction, of cable connections and of the monitor system. The feasibitity of data transfer from the system at the target position to the user's system and the mode of acceptance of external data are explained. (orig./HP) [de

  12. Android Based Area Web Monitoring

    Science.gov (United States)

    Kanigoro, Bayu; Galih Salman, Afan; Moniaga, Jurike V.; Chandra, Eric; Rezky Chandra, Zein

    2014-03-01

    The research objective is to develop an application that can be used in the monitoring of an area by using a webcam. It aims to create a sense of security on the user's application because it can monitor an area using mobile phone anywhere. The results obtained in this study is to create an area with a webcam monitoring application that can be accessed anywhere as long as the monitoring results have internet access and can also be accessed through Android Based Mobile Phone.

  13. Android Based Area Web Monitoring

    Directory of Open Access Journals (Sweden)

    Kanigoro Bayu

    2014-03-01

    Full Text Available The research objective is to develop an application that can be used in the monitoring of an area by using a webcam. It aims to create a sense of security on the user's application because it can monitor an area using mobile phone anywhere. The results obtained in this study is to create an area with a webcam monitoring application that can be accessed anywhere as long as the monitoring results have internet access and can also be accessed through Android Based Mobile Phone.

  14. Nuclear accident dosimetry intercomparison studies at the Health Physics Research Reactor: a summary (1965-1978)

    International Nuclear Information System (INIS)

    Sims, C.S.; Dickson, H.W.

    1979-01-01

    Fifteen nuclear accident dosimetry intercomparison studies utilizing the fast pulsed Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a growing number of participants with a forum for discussing and learning more about accident dosimetry systems and with opportunity to test their systems under simulated nuclear accident conditions and to compare their results with those of others making measurements under identical conditions. Shielded and unshielded measurements of the neutron and the gamma doses to phantoms and at area monitoring stations have been made with a wide variety of dosimeter types. The large amount of data available from these measurements throughout the years is summarized, analyzed and discussed. The information in this summary provides an indication of the status of and trends in nuclear accident dosimetry. (author)

  15. Radiation dosimetry and spectrometry with superheated emulsions

    International Nuclear Information System (INIS)

    D'Errico, Francesco

    2001-01-01

    Detectors based on emulsions of overexpanded halocarbon droplets in tissue equivalent aqueous gels or soft polymers, known as 'superheated drop detectors' or 'bubble (damage) detectors', have been used in radiation detection, dosimetry and spectrometry for over two decades. Recent technological advances have led to the introduction of several instruments for individual and area monitoring: passive integrating meters based on the optical or volumetric registration of the bubbles, and active counters detecting bubble nucleations acoustically. These advances in the instrumentation have been matched by the progress made in the production of stable and well-specified emulsions of superheated droplets. A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e. a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons. More recently, halocarbons with an elevated degree of superheat have been utilised to produce emulsions that nucleate with much smaller energy deposition and detect low linear energy transfer radiations, such as photons and electrons. This paper reviews the detector physics of superheated emulsions and their applications in radiation measurements, particularly in neutron dosimetry and spectrometry

  16. Internal dosimetry monitoring equipment: Present and future

    International Nuclear Information System (INIS)

    Selby, J.; Carbaugh, E.H.; Lynch, T.P.; Strom, D.J.; Lardy, M.M.

    1993-09-01

    We have attempted to characterize the current and future status of in vivo and in vitro measurement programs coupled with the associated radioanalytical methods and workplace monitoring. Developments in these areas must be carefully integrated by internal dosimetrists, radiochemists and field health physicists. Their goal should be uniform improvement rather than to focus on one specific area (e.g., dose modeling) to the neglect of other areas where the measurement capabilities are substantially less sophisticated and, therefore, the potential source of error is greatest

  17. Accuracy and precision in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1984-01-01

    The question of accuracy and precision in thermoluminescent dosimetry, particularly in relation to lithium fluoride phosphor, is discussed. The more important sources of error, including those due to the detectors, the reader, annealing and dosemeter design, are identified and methods of reducing their effects on accuracy and precision to a minimum are given. Finally, the accuracy and precision achievable for three quite different applications are discussed, namely, for personal dosimetry, environmental monitoring and for the measurement of photon dose distributions in phantoms. (U.K.)

  18. The OECD/NEA programme on radon and thoron dosimetry and monitoring: its contribution to the assessment of public exposure to natural radiation

    International Nuclear Information System (INIS)

    Ilari, O.; Steinhaeusler, F.

    1984-01-01

    Inhalation of radon, thoron and their daughters is recognised to be the most important pathway to exposure of mankind to natural radiation sources. The progressive understanding of the increasing role of this exposure in the overall radiation detriment to the public and the workers produced an increasing concern in several countries about the problems of dosimetry and measurement of these nuclides. This trend was readily appreciated by NEA, which began an active programme in this field in 1976. The effort of NEA focussed on two main areas, namely (a) development of dosimetric models and study of correlation between exposure and dose (Phase I), and (b) review of principles and techniques of metrology and development of guidance on monitoring (Phase II). (author)

  19. A European network of experts with direct responsibility for monitoring and dosimetry after a deliberate release of radioactive material or a deliberate radiation exposure

    International Nuclear Information System (INIS)

    Rahola, Tua; Muikku, Maarit; Pellow, Peter G.D.; Etherington, George; Hodgson, Alan; Youngman, Mike J.; Le Guen, Bernard; Berard, Philippe; Lopez, Maria A.

    2008-01-01

    In the event of an accidental or deliberate release of radionuclides to the environment, individual monitoring and dose assessment may be needed for large numbers of people. The consequences of such incidents are not limited by national boundaries. However, within the European Union (EU), there has not been any coordinated strategy for individual monitoring and dose assessment. CONRAD (CO-ordination Action for Radiation Dosimetry) is an EC 6 th Framework Programme Co-ordination Action sponsored by EURADOS (the European Radiation Dosimetry Group, http://www.eurados.org). The objective of Task 5.4 of Work Package 5 of the CONRAD project, coordinated by HPA (UK) and STUK (Finland), is the development of a network of people and organisations with responsibilities for emergency monitoring of emergency services personnel and members of the public. The network (named EUREMON) aims to promote sharing of information between countries on plans and arrangements for individual monitoring. It currently has 51 individual members from 22 EU countries, 8 non-EU countries and two international organisations. After it was established, the network was used in a survey of plans and arrangements for emergency personal monitoring in EU countries. Information is also being compiled on portable and transportable monitoring facilities and equipment in the EU. (author)

  20. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  1. What is New in Internal Dosimetry and Monitoring?

    International Nuclear Information System (INIS)

    Henrichs, K.; Nosske, D.

    2006-01-01

    This file is divided in two parts:the first one concerns the progress in internal dosimetry. This part gives an overview on new model developments by ICRP, the series of age dependent doses for members of the public was continued by biokinetic and dosimetric models for the embryo and foetus due to activity intake by the mother (ICRP,2001) and for the infant via consumption of mother's milk after activity intake by the mother (ICRP, 2004). In both publications dose coefficients for the embryo and foetus as well the infant were given for various intake scenarios by mother. The present model development work of ICRP is a revision of Publications 30, 54, 68, and 78 based on the new human Alimentary tract model (H.A.T.M.) of ICRP (ICRP, 2006), a revision of absorption parameters for the human respiratory tract model (ICRP, 1994a), new systemic models as well as new dosimetric parameters derived with new Voxel models for the reference male and female adult. The second part concerns the progress in workers monitoring for radionuclide intake. The initiatives to improve the situation are the guidelines published by the International Atomic Energy Agency (2004), giving guidance for the assessment of occupational exposures due to intakes of radionuclides, research project funded by the European Commission: the objective of O.M.I.N.E.X. was the improvement of monitoring programmes, taking into account the uncertainties of biokinetic models and data, the programme I.D.E.A. tried to improve measuring techniques and I.D.E.A.S derives rules for the evaluation of measured activity values in terms of exposure. Standardization projects by the International Standardization Organization I.S.O.: I.S.O. (2001) published a standard defining the requirements for bioassay laboratories, which will soon followed by a second part giving the rationale behind these rules., presently the final version (I.S.O. 2005) of a standard is circulating among the I.S.O. member states which guidance on the

  2. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  3. Personal Dosimetry Enhancement for Underground Workplaces

    Directory of Open Access Journals (Sweden)

    L. Thinová

    2005-01-01

    Full Text Available Personal dosimetry for underground workers mainly concerns measurement of the concentration of radon (and its daughters and the correct application of the data in dose calculation, using a biokinetic model for lung dosimetry. A conservative approach for estimating the potential dose in caves (or underground is based on solid state alpha track detector measurements. The obtained dataset is converted into an annual effective dose in agreement with the ICRP recommendations using the “cave factor”, the value of which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached and the attached fraction and on the equilibrium factor. The main difference between apartments and caves is the absence of aerosol sources, high humidity, low ventilation rate and the uneven surface in caves. A more precisely determined dose value would have a significant impact on radon remedies or on restricting the time workers stay underground. In order to determine  how the effective dose is calculated, it is necessary to divide these areas into distinct categories by the following measuring procedures: continual radon measurement (to capture the differences in EERC between working hours and night-time, and also between daily and seasonal radon concentration variations; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of 218Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoils and in water inside/outside, a study of the radon sources in the cave; aerosol particle-size spectrum measurements to determine the free fraction; monitoring the behaviour of guides and workers to record the actual time spent in the cave, in relation to the continuously monitored levels of Rn concentration. 

  4. Direct biological dosimetry in Chernobyl clear-up workers

    International Nuclear Information System (INIS)

    Maznik, N.A.; Vinnikov, V.A.; Rozdil'ski, S.I.

    1999-01-01

    Full text: In cases of large-scale radiological accidents like Chernobyl (1986) the estimation of somatic risk to exposed populations became a problem due to lack of direct physical dosimetry data. In such conditions the necessarily information can be obtained from biological dosimetry, firstly by chromosomal aberrations analysis in human peripheral blood lymphocytes. Conventional cytogenetic assay have been carried out in 130 persons recruited as clean-up workers ('liquidators') to the Chernobyl zone in 1986-87 yrs. Blood sampling was performed during 1 year post-irradiation, in 100 persons p to 0.5 year. The aberrations of choice for biological dosimetry were unstable chromosome exchanges (dicentrics and centric rings with accompanying acentric fragments). The dose calculations have been done using the linear term of the dose-response curve built with acute gamma-irradiation of blood in dose range up to 1 Gy. The distributions of biological doses were investigated in groups of liquidators with doses in documents ranging 17-140, 175-230, 250, 260-365, 440-1030 mSv and in the group of non-monitored persons. The weak correlation between monitored individual doses and biological doses was shown; the biological and physical dose distribution peculiarity in monitored groups is discussed. The distribution of individual aberration frequencies and the average yield of chromosomal exchanges in monitored and non-monitored liquidators were identical. The common cohort analysis (monitored and non-monitored persons) showed that the individual aberration yields distribution among liquidators was strictly randomised in accordance with Poissonian statistics. The cytogenetic dose estimations obtained can be of great value for somatic effects risk assessment in post-Chernobyl cohorts

  5. ESR/tooth enamel dosimetry application to Chernobyl case: individual retrospective dosimetry of the liquidators and wild animals

    International Nuclear Information System (INIS)

    Bugai, A.; Baryakchtar, V.G.; Baran, N.

    1996-01-01

    ESR/tooth enamel dosimetry technique was used for individual retrospective dosimetry of the servicemen who had worked in 1986-1987 at the liquidation of consequences of the Chernobyl accident. For 18 investigated cases, the values varied from 0,10 (sensitivity limit) to 1,75 Gy. The same technique was used for individual dosimetry of wild animals boars, red deers, elks) hunted at contaminated 30-km area around the Chernobyl Power Plant. Measured values varied from 0,20 to 5,0 Gy/year and were compared with calculated for external and internal irradiation

  6. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  7. Some practical and theoretical considerations of personal alpha-particle dosimetry. Joint panel on occupational and environmental research for uranium production in Canada (JP-2)

    Energy Technology Data Exchange (ETDEWEB)

    Bigu, J [Department of Energy, Mines and Resources, Elliot Lake, ON (Canada). Elliot Lake Lab.; Duport, P [Atomic Energy Control Board, Ottawa, ON (Canada)

    1990-12-31

    The status of personal {alpha}-particle dosimetry in the uranium industry is presented. A brief description of personal dosimeters and prototypes is followed by some theoretical considerations regarding their practical use under steady-state and time-dependent field conditions. It is suggested that, at present, more effort should be placed on the evaluation of dosimeters than in the development of new ones. Also, more information should be gathered from countries which use personal {alpha}-particle dosimeters routinely. Furthermore, emphasis is recommended on comparison of personal dosimetry data with experimental data by area monitoring, using continuous monitoring systems, as well as with data by grab-sampling techniques. (author). 44 refs., 1 tab.

  8. Some practical and theoretical considerations of personal alpha-particle dosimetry. Joint panel on occupational and environmental research for uranium production in Canada (JP-2)

    International Nuclear Information System (INIS)

    Bigu, J.

    1989-01-01

    The status of personal α-particle dosimetry in the uranium industry is presented. A brief description of personal dosimeters and prototypes is followed by some theoretical considerations regarding their practical use under steady-state and time-dependent field conditions. It is suggested that, at present, more effort should be placed on the evaluation of dosimeters than in the development of new ones. Also, more information should be gathered from countries which use personal α-particle dosimeters routinely. Furthermore, emphasis is recommended on comparison of personal dosimetry data with experimental data by area monitoring, using continuous monitoring systems, as well as with data by grab-sampling techniques. (author). 44 refs., 1 tab

  9. Radiation dosimetry onboard the International Space Station ISS

    International Nuclear Information System (INIS)

    Berger, Thomas

    2008-01-01

    Besides the effects of the microgravity environment, and the psychological and psychosocial problems encountered in confined spaces, radiation is the main health detriment for long duration human space missions. The radiation environment encountered in space differs in nature front that on earth, consisting mostly of high energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones encountered on earth for occupational radiation workers. Therefore the determination and the control of the radiation load on astronauts is a moral obligation of the space faring nations. The requirements for radiation detectors in space are very different to that on earth. Limitations in mass, power consumption and the complex nature of the space radiation environment define and limit the overall construction of radiation detectors. Radiation dosimetry onboard the International Space Station (ISS) is accomplished to one part as ''operational'' dosimetry aiming for area monitoring of the radiation environment as well as astronaut surveillance. Another part focuses on ''scientific'' dosimetry aiming for a better understanding of the radiation environment and its constitutes. Various research activities for a more detailed quantification of the radiation environment as well as its distribution in and outside the space station have been accomplished in the last years onboard the ISS. The paper will focus on the current radiation detectors onboard the ISS, their results, as well as on future planned activities. (orig.)

  10. Twenty-first nuclear accident dosimetry intercomparison study, August 6-10, 1984

    International Nuclear Information System (INIS)

    Swaja, R.E.; Ragan, G.E.; Sims, C.S.

    1985-05-01

    The twenty-first in a series of nuclear accident dosimetry (NAD) intercomparison (NAD) studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 6-10, 1984. The Health Physics Research Reactor operated in the pulse mode was used to simulate three criticality accidents with different radiation fields. Participants from five organizations measured neutron doses between 0.53 and 4.36 Gy and gamma doses between 0.19 and 1.01 Gy at area monitoring stations and on phantoms. About 75% of all neutron dose estimates based on foil activation, hair activation, simulated blood sodium activation, and thermoluminescent methods were within +-25% of reference values. Approximately 86% of all gamma results measured using thermoluminescent (TLD-700 or CaSO 4 ) systems were within +-20% of reference doses which represents a significant improvement over previous studies. Improvements observed in the ability of intercomparison participants to estimate neutron and gamma doses under criticality accident conditions can be partly attributed to experience in previous NAD studies which have provided practical tests of dosimetry systems, enabled participants to improve evaluation methods, and standardized dose reporting conventions. 16 refs., 15 tabs

  11. Individual dosimetry of workers and patients: implementation and perspectives; La dosimetrie individuelle des travailleurs et de patients: mise en oeuvre et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E

    2008-07-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  12. First national intercomparison of personal dosimetry for dosimetry service providers in paec

    International Nuclear Information System (INIS)

    Akhter, J.; Ahmed, S.S.

    2006-12-01

    Health Physics Division, PINSTECH, has conducted an intercomparison exercise for PAEC organizations which are responsible for providing personal dosimetry services for the assessment of occupational doses of radiation workers. The exercise was on voluntary basis and it was designed to harmonize the procedure of individual dose monitoring techniques in terms of new ICRP operational quantities of personal dose equivalent Hp (10) for photons. Cobalt-60 and Cesium-137 protection level sources were used for irradiation. The dosimeters were exposed to radiation in the range of 0.46 to 24.20 mSv. Irradiations were performed in Secondary Standard Dosimetry Laboratory (SSDL) at HPD, PINSTECH according to IAEA/WHO standards. The performance of the participating laboratories was judged by trumpet curve that provides the acceptable limits on overall accuracy for occupational dose monitoring at 95% confidence level according to international standards. The response of measured dose/standard true dose (Hm/Ht lies in the range of 0.66 to 1.11 for 60CO and 0.84 to 1.17 for 137CS. This report describes the procedure and results of the intercomparison exercise. (author)

  13. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.

    Science.gov (United States)

    Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I

    2016-09-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. What is New in Internal Dosimetry and Monitoring?

    Energy Technology Data Exchange (ETDEWEB)

    Henrichs, K. [Siemens AG, Corporate Radiation Safety and Dangerous Goods Transport, Munich (Germany); Nosske, D. [Federal Office for Radiation Protection, Neuherberg (Germany)

    2006-07-01

    This file is divided in two parts:the first one concerns the progress in internal dosimetry. This part gives an overview on new model developments by ICRP, the series of age dependent doses for members of the public was continued by biokinetic and dosimetric models for the embryo and foetus due to activity intake by the mother (ICRP,2001) and for the infant via consumption of mother's milk after activity intake by the mother (ICRP, 2004). In both publications dose coefficients for the embryo and foetus as well the infant were given for various intake scenarios by mother. The present model development work of ICRP is a revision of Publications 30, 54, 68, and 78 based on the new human Alimentary tract model (H.A.T.M.) of ICRP (ICRP, 2006), a revision of absorption parameters for the human respiratory tract model (ICRP, 1994a), new systemic models as well as new dosimetric parameters derived with new Voxel models for the reference male and female adult. The second part concerns the progress in workers monitoring for radionuclide intake. The initiatives to improve the situation are the guidelines published by the International Atomic Energy Agency (2004), giving guidance for the assessment of occupational exposures due to intakes of radionuclides, research project funded by the European Commission: the objective of O.M.I.N.E.X. was the improvement of monitoring programmes, taking into account the uncertainties of biokinetic models and data, the programme I.D.E.A. tried to improve measuring techniques and I.D.E.A.S derives rules for the evaluation of measured activity values in terms of exposure. Standardization projects by the International Standardization Organization I.S.O.: I.S.O. (2001) published a standard defining the requirements for bioassay laboratories, which will soon followed by a second part giving the rationale behind these rules., presently the final version (I.S.O. 2005) of a standard is circulating among the I.S.O. member states which guidance on

  15. Absolute and relative dosimetry for ELIMED

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics Czech Academy of Science, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Leonora, E.; Randazzo, N. [INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Presti, D. Lo [INFN-Sezione di Catania, Via Santa Sofia 64, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Raffaele, L. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Tramontana, A. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Cirio, R.; Sacchi, R.; Monaco, V. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino, Italy and Università di Torino, Dipartimento di Fisica, Via P.Giuria, 1 10125 Torino (Italy); Marchetto, F.; Giordanengo, S. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino (Italy)

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  16. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  17. The development of web monitoring digital area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su

    2005-01-01

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system

  18. The development of web monitoring digital area monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su [Iljin Radiation Engineering Co., Seoul (Korea, Republic of)

    2005-11-15

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system.

  19. Individual dosimetry of workers and patients: implementation and perspectives

    International Nuclear Information System (INIS)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  20. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: In June: Every morning from 8:30 to 12:00 In July: Mondays, Wednesdays and Fridays from 8:30 to 11:30 Closed all day on Tuesdays and Thursdays From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  1. Extremity dosimetry at US Department of Energy facilities

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; MacLellan, J.A.

    1986-05-01

    A questionnaire on extremity dosimetry was distributed to DOE facilities along with a questionnaire on beta dosimetry. An informal telephone survey was conducted as a follow-up survey to answer a few additional questions concerning extremity monitoring practices. The responses to the questionnaire and the telephone survey are summarized in this report. Background information, developed from operational experience and a review of the current literature, is presented as a basis for understanding the information obtained by the survey and questionnaire

  2. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  3. The Seibersdorf TL Personnel Dosimetry Service

    Energy Technology Data Exchange (ETDEWEB)

    Duftschmid, K E [Oesterreichisches Forschungszentrum Seibersdorf GmbH (Austria)

    1994-11-01

    Since 1976 the Department for Radiation Protection of the Austrian Research Centre Seibersdorf has been operating a TLD Personnel Monitoring Service, which presently covers about 18,000 radiation workers in Austria, with monthly monitoring periods. We have been the first accredited monitoring service in Europe, which fully converted from film dosimetry to TLD. From the beginning up to 1991 the service was based on three automated TLD systems Model 2271 from HARSHAW, USA. After extensive testing and comparisons, since almost four years now, the monitoring service has been operating on two HARSHAW 8800 systems, which are described in more detail below. (author).

  4. The Seibersdorf TL Personnel Dosimetry Service

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1994-11-01

    Since 1976 the Department for Radiation Protection of the Austrian Research Centre Seibersdorf has been operating a TLD Personnel Monitoring Service, which presently covers about 18,000 radiation workers in Austria, with monthly monitoring periods. We have been the first accredited monitoring service in Europe, which fully converted from film dosimetry to TLD. From the beginning up to 1991 the service was based on three automated TLD systems Model 2271 from HARSHAW, USA. After extensive testing and comparisons, since almost four years now, the monitoring service has been operating on two HARSHAW 8800 systems, which are described in more detail below. (author)

  5. Non-ionizing electromagnetic exposure assessment and dosimetry

    International Nuclear Information System (INIS)

    Paulsson, L.E.

    1992-11-01

    A comprehensive literature survey of advancements in the area 'human exposure assessment and dosimetry' for the years 1988-1992 has been performed by the author and published elsewhere. In the present report that material has been complemented with a historical background and a thorough description of the physical principles behind the methods and techniques. The report covers strategies, principles, methods, limitations and future developments for the area of human exposure assessment and dosimetry of electromagnetic fields form extremely low frequencies up to and including microwaves

  6. Report of a consultants meeting on dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Pernicka, F.

    1999-01-01

    During its biennial meeting in 1996, the Standing Advisory Committee 'SSDL Scientific Committee', recommended extending the long experience of the Agency in the field of standardization and monitoring dosimetry calibrations at radiotherapy and radiation protection level for the Secondary Standard Dosimetry Laboratory (SSDL) Network, to the field of diagnostic x-ray dosimetry. It was emphasized that 'Measurements on diagnostic x-ray machines have become increasingly important and some SSDLs are involved in such measurements. The Agency's dosimetry laboratory should, therefore, have proper radiation sources available to provide traceable calibrations to the SSDLs'. The purpose of the consultants' meeting was to advise the Agency on dosimetry in diagnostic radiology. They were specifically requested to overview scientific achievements in the field and to give advice to the Agency on the need for further developments. The purpose of the consultants' meeting was to advise the Agency on dosimetry in diagnostic radiology. They were specifically requested to overview scientific achievements in the field and to give advice to the Agency on the need for further developments

  7. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2009-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry. Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  8. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2008-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry . Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  9. Radiation dosimetry onboard the International Space Station ISS

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Thomas [German Aerospace Center - DLR, Inst. of Aerospace Medicine, Radiation Biology, Cologne (Germany)

    2008-07-01

    Besides the effects of the microgravity environment, and the psychological and psychosocial problems encountered in confined spaces, radiation is the main health detriment for long duration human space missions. The radiation environment encountered in space differs in nature front that on earth, consisting mostly of high energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones encountered on earth for occupational radiation workers. Therefore the determination and the control of the radiation load on astronauts is a moral obligation of the space faring nations. The requirements for radiation detectors in space are very different to that on earth. Limitations in mass, power consumption and the complex nature of the space radiation environment define and limit the overall construction of radiation detectors. Radiation dosimetry onboard the International Space Station (ISS) is accomplished to one part as 'operational' dosimetry aiming for area monitoring of the radiation environment as well as astronaut surveillance. Another part focuses on 'scientific' dosimetry aiming for a better understanding of the radiation environment and its constitutes. Various research activities for a more detailed quantification of the radiation environment as well as its distribution in and outside the space station have been accomplished in the last years onboard the ISS. The paper will focus on the current radiation detectors onboard the ISS, their results, as well as on future planned activities. (orig.)

  10. Dosimetry-based treatment planning for molecular radiotherapy: a summary of the 2017 report from the Internal Dosimetry Task Force

    Directory of Open Access Journals (Sweden)

    Caroline Stokke

    2017-11-01

    Full Text Available Abstract Background The European directive on basic safety standards (Council directive 2013/59 Euratom mandates dosimetry-based treatment planning for radiopharmaceutical therapies. The directive comes into operation February 2018, and the aim of a report produced by the Internal Dosimetry Task Force of the European Association of Nuclear Medicine is to address this aspect of the directive. A summary of the report is presented. Results A brief review of five of the most common therapy procedures is included in the current text, focused on the potential to perform patient-specific dosimetry. In the full report, 11 different therapeutic procedures are included, allowing additional considerations of effectiveness, references to specific literature on quantitative imaging and dosimetry, and existing evidence for absorbed dose-effect correlations for each treatment. Individualized treatment planning with tracer diagnostics and verification of the absorbed doses delivered following therapy is found to be scientifically feasible for almost all procedures investigated, using quantitative imaging and/or external monitoring. Translation of this directive into clinical practice will have significant implications for resource requirements. Conclusions Molecular radiotherapy is undergoing a significant expansion, and the groundwork for dosimetry-based treatment planning is already in place. The mandated individualization is likely to improve the effectiveness of the treatments, although must be adequately resourced.

  11. Database to manage personal dosimetry Hospital Universitario de La Ribera

    International Nuclear Information System (INIS)

    Melchor, M.; Martinez, D.; Asensio, M.; Candela, F.; Camara, A.

    2011-01-01

    For the management of professionally exposed personnel dosimetry, da La are required for the use and return of dosimeters. in the Department of Radio Physics and Radiation Protection have designed and implemented a database management staff dosimetry Hospital and Area Health Centers. The specific objectives were easily import data from the National Center dosimetric dosimetry, consulting records in a simple dosimetry, dosimeters allow rotary handle, and also get reports from different periods of time to know the return data for users, services, etc.

  12. Working conditions analysis according T.L. personal dosimetry results

    International Nuclear Information System (INIS)

    Marinkovic, O.; Jovanovic, S.

    2006-01-01

    Laboratory for personal dosimetry in the Institute of Occupational and Radiological Health, Belgrade, used TLD more than twenty years. Before that, film dosimetry was main method in external monitoring. T.L. dosimetry was started with Reader Toledo 654 and crystals Mg B 4 O 7 . Finally, from 1992 laboratory has Harshaw TLD Reader Model 6600. Dosimeters are crystals LiF type 100, card packed, worn in standard filtrated holders. Personal dosimetry data are keeping 30 years for each worker according to regulations. The data from 1990 are in electronic form. Long experience enables conclusion that new technique means more advantages in practice. Recommendation from this laboratory practice refers to TLD read-out cycle. The longest period should be one month. LiF is recommended crystal. Glow curve deconvolution gives information about chronological irradiation. It is very important to conclude was dosimetry irradiated by 'one-shot' or continuously. Preparing calibration for determination the time since accident laboratory has to define adequate dose calibration methodology including low temperature peaks. Possibility to follow working conditions analyzing TLD glow curve is much more important than low decrease of dose severity. Time depend analyze is not possible if TLD would be read-out more than (approximately) six weeks after irradiation. If ionizing sources produce such low dose and has negligible probability of accidental exposure (according nowadays regulation read-out frequency could be once in three month), the recommendation is not to use external personal monitoring. Reading personal dosimeters once in three months deemed not useful. Complete and successful personal dosimetry dictates using system that enables glow curve shape representation to be sure that signal is ionizing irradiation result or not. Time depend analyze imparts information about protection permanence. In special circumstance, it is possible to estimate the time of exposure. This is extremely

  13. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    1999-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact the Individual Dosimetry ServiceWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period JANUARY/FEBRUARY will be available from their usual dispatchers on Monday the third of January 2000.Please have your films changed:before the 12 January.The colour of the dosimeter valid in JANUARY/FEBRUARY is WHITE.

  14. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact the Individual Dosimetry Service.We inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MARCH/APRIL will be available from their usual dispatchers on the third of March 2000.Please have your films changed before the 13th of March.The colour of the dosimeter valid in MARCH/APRIL is BLUE.

  15. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-24

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

  16. The challenge of Ciemat internal dosimetry service for accreditation according to ISO/IEC 17025 standard, for in vivo and in vitro monitoring and dose assessment of internal exposures

    International Nuclear Information System (INIS)

    Lopez, M.A.; Martin, R.; Hernandez, C.; Navarro, J.F.; Navarro, T.; Perez, B.; Sierra, I.

    2016-01-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. CIEMAT Internal Dosimetry Service (IDS) has developed and implemented a quality system based on ISO/IEC 17025 to ensure compliance with the general requirements of this reference standard. The development of documentary support according to this quality system permitted to standardise the systematic activities performed within the whole body counter and in vitro bioassay laboratories as well as the procedures carried out by qualified staff in charge of internal dose assessment. There was no previous experience in the accreditation of other internal dosimetry services in Spain. Then, requirements from the national regulatory body (Nuclear Safety Council, CSN) and national accreditation entity (ENAC) have been considered. The main concerns were to guarantee the traceability in the whole process and to avoid possible charge of interpretation or subjectivity in the methodology of dose assessment due to intakes of radionuclides when calculating from monitoring data. All the related international standards dealing with internal dosimetry were taken into account: ISO 28218 'Performance criteria for radiobioassay', ISO 27048 'Dose Assessment for the

  17. In vivo dosimetry in radiation therapy in Sweden

    International Nuclear Information System (INIS)

    Eriksson, Jacob; Blomquist, Michael

    2010-07-01

    A prerequisite for achieving high radiation safety for patients receiving external beam radiation therapy is that the hospitals have a quality assurance program. The program should include include monitoring of the radiation dose given to the patient. Control measurements are performed both at the system level and at the individual level. Control measurement is normally performed using in vivo dosimetry, e.g. a method to measure the radiation dose at the individual level during the actual radiation treatment time. In vivo dosimetry has proven to be an important tool to detect and prevent serious errors in patient treatment. The purpose of this research project was to identify the extent to which vivo dosimetry is used and the methods available for this at Swedish radiation therapy clinics. The authority also wanted to get an overall picture of how hospitals manage results of in vivo dosimetry, and how clinics control radiation dose when using modern treatment techniques. The report reflects the situation in Swedish radiotherapy clinics 2007. The report shows that all hospitals use some form of in vivo dosimetry. The instruments used are mainly diodes and termoluminiscence dosimeters

  18. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  19. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the

  20. OSL and TL of Resistors of Mobile Phones for Retrospective Accident Dosimetry

    International Nuclear Information System (INIS)

    Lee, J. I.; Kim, J. L.; Pradhan, A. S.; Chang, I.; Kim, B. H.

    2012-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (TL) of ubiquitous materials continue to draw wider attention for individual dosimetry in nuclear and radiation accidents. Use of ubiquitous objects for radiation dosimetry is preferred because the affected persons in such unexpected events are usually not covered by personal dosimetry services and do not carry personal dosimeters. Often accident sites do not have area monitoring system in place. As the main concern of the dosimetry is health effects, a quick distinction of level of exposures of the affected persons for the required medical care becomes important in all accidents involving radiation. Both in large scale nuclear accidents such Fukushima, Chernobyl or Hiroshima and Nagasaki where large population around the accident site get exposed to radiation (evacuation is based on doses) and in smaller but panicky events, such as misuse of radiological exposure device (RED), radiological dispersive device (RDD: 'Dirty Bomb'), improvised nuclear device (IND) and deliberate dispersal of radioactive contaminants, a need for an ubiquitous personal dosimeter is well recognized. As biological dosimetry systems are yet to become viable for measurements of doses with required accuracy and speed, use of physical dosimeters is often explored. Among the various types of physical dosimetry systems, use of TL and OSL by processing common material such as bricks or tiles and measuring the doses cumulated for long periods of time has already become an accepted tool for large scale nuclear accidents such as Hiroshima and Nagasaki or Chernobyl involving higher doses. In the other potential cases of unexpected situations where the doses encountered could be much lower (even to escape the range of remotely installed area monitors), the need to measure even the low doses in shortest possible time becomes important. It is often realized that in such situations, the main problem could become the panic at the work place

  1. Applied internal dosimetry staff exposed to Uranium

    International Nuclear Information System (INIS)

    Trotta, Marisa V.; Arguelles, Maria G.

    2009-01-01

    Dosimetric calculations are performed in order to estimate the quantity of a radionuclide that is incorporated by a worker. Urine determinations of activity and mass of uranium are made in the laboratory of Personal and Area Dosimetry. The paper presents reference values concerning the activity excreted in urine due to the incorporation of uranium compounds. The compounds analyzed are natural uranium and uranium enriched to 20 %, both soluble and insoluble. According to the limits allowed for the incorporation of uranium compounds of Type F and M, we verify that the times of monitoring and the detection limits of the equipment used to determine the activity are appropriate. On the other hand, the S-type compounds determination in urine is useful in cases of accidental incorporations (above the ALI) as a first and quick estimate; MDA (0.017 Bq / L) does not allow detection in routine monitoring; measurement in lungs, and faeces should be included. (author)

  2. Radiation chemical dosimetry by means of nitrate-nitrite

    International Nuclear Information System (INIS)

    Tormo Ferrero, M.J.

    1977-01-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolisis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (author) [es

  3. Feasibility of using local bricks for retrospective dosimetry

    International Nuclear Information System (INIS)

    Singh, A.K.; Menon, S.N.; Kadam, S.Y.; Koul, D.K.

    2016-01-01

    Rising nuclear power industry, application of radioactive materials in medical industry, nuclear proliferation and terrorist activities pose risk of nuclear and radiological incidents. In the event of such an incident accurate radiation dosimetry is necessary to address the immediate and long term personal and public concerns. Absorbed radiation doses of occupationally exposed workers can be carried out using standard conventional dosimeters and monitoring systems. However, there is a growing concern about the estimation of radiation doses to non radiation workers or public in case of a nuclear or radiological accident occurring in large area which do not have adequate monitoring system. In such situations non conventional dosimeters such as bricks, tiles or other natural materials have been proposed for retrospective determination of dose. In this study we explore the use of OSL from quartz extracted from red bricks manufactured in kilns located in the Mumbai metropolitan region

  4. Dosimetry Measurements around the Angiography Units Using Thermoluminescence Detectors (TLD)

    International Nuclear Information System (INIS)

    Salah El-den, T.; Shahein, A.Y.; Gomaa, M.A.

    2008-01-01

    The thermoluminescent dosimeters (TLDs) are widely used not only in the field of personnel monitoring (dosimetry) service for ionizing radiation to medical, and research communities, but also for measurements of X-rays emitted from different angiography's unit. Measurements ionizing radiation around the bed area during cardiac catheterization procedures using X-rays was measured. TLD Badges used to determine the annual effective doses, the safe distance for the staff to minimize radiation exposure and the effectiveness of shield and used leaded apron. The results indicated that annual effective dose for by angiography cardiac Catheterization room may exceed the limits

  5. Quality control through dosimetry at a contract radiation processing facility

    International Nuclear Information System (INIS)

    Du Plessis, T.A.; Roediger, A.H.A.

    1985-01-01

    Reliable dosimetry procedures constitute a very important part of process control and quality assurance at a contract gamma radiation processing facility that caters for a large variety of different radiation applications. The choice, calibration and routine intercalibration of the dosimetry systems employed form the basis of a sound dosimetry policy in radiation processing. With the dosimetric procedures established, detailed dosimetric mapping of the irradiator upon commissioning (and whenever source modifications take place) is carried out to determine the radiation processing characteristics and peformance of the plant. Having established the irradiator parameters, routine dosimetry procedures, being part of the overall quality control measures, are employed. In addition to routine dosimetry, independent monitoring of routine dosimetry is performed on a bi-monthly basis and the results indicate a variation of better than 3%. On an annaul basis the dosimetry systems are intercalibrated through at least one primary standard dosimetry laboratory and to date a variation of better than 5% has been experienced. The company also participates in the Pilot Dose Assurance Service of the International Atomic Energy Agency, using the alanine/ESR dosimetry system. Routine calibration of the instrumentation employed is carried out on a regular basis. Detailed permanent records are compiled on all dosimetric and instrumentation calibrations, and the routine dosimetry employed at the plant. Certificates indicating the measured absorbed radiation doses are issued on request and in many cases are used for the dosimetric release of sterilized medical and pharmaceutical products. These procedures, used by Iso-Ster at its industrial gamma radiation facility, as well as the experience built up over a number of years using radiation dosimetry for process control and quality assurance are discussed. (author)

  6. Characterization of plutonium contamination at Maralinga: Dosimetry and cleanup criteria

    International Nuclear Information System (INIS)

    Cooper, M.B.; Martin, L.J.; Williams, G.A.; Harries, J.R.

    2000-01-01

    An area of South Australia remained contaminated following British atomic tests at Maralinga during 1955-1963. Of importance is the long lived 239 Pu of which some 24 kg was explosively dispersed in several 'minor trials'. The extent, quantities and physical characteristics of the plutonium have been assessed and estimates of dose, dominated by the inhalation pathway in the critical group of Aborigines living a semi-traditional lifestyle, have been made for potential occupants. Dosimetry, together with social and economic factors, underpins the setting of cleanup criteria in terms of activity concentrations averaged over large areas and permissible concentrations of contaminated particles. The possibility of intentional behaviour such as fragment scavenging has also influenced limits on particulate contamination. Rehabilitation of the most contaminated areas is underway, with scraping of surface soil and burial on site completed. Vehicular-mounted radiation detector systems for wide area and particle monitoring have been developed, and procedures established for determining cleanup boundaries and for the verification monitoring to ensure that the cleanup process has met the specified criteria. Data are being obtained for a final dose and health risk assessment of the cleaned up site. (author)

  7. Internal Dosimetry Monitoring- Detection Limits for a Selected Set of Radionuclides and Their Translation Into Committed Effective Dose

    International Nuclear Information System (INIS)

    Brandl, A.; Hrnecek, E.; Steger, F.

    2004-01-01

    To harmonize the practice of internal dosimetry monitoring across the country, the Austrian Standards Institute is currently drafting a new set of standards which are concerned with occupational incorporation monitoring of individuals handling non-sealed radioactive material. This set of standards is expected to consist of three parts discussing the general necessity and frequency, the requirements for monitoring institutions, and the determination and rigorous calculation of committed effective dose after incorporation of radioactive material, respectively. Considerations of the requirements for routine monitoring laboratories have led to an evaluation of the detection limits for routine monitoring equipment. For a selected set of radionuclides, these detection limits are investigated in detail. The main emphasis is placed on the decay chains of naturally occurring radionuclides showing some significant potential for being out of equilibrium due to chemical processes in certain mining industries. The radionuclides considered in this paper are 226Ra, 228Ra, 228Th, 232Th, 234U, 235U, and 238U. Given the routine monitoring intervals of the Austrian Standard, these detection limits are translated into information on committed effective dose. This paper investigates whether routine monitoring equipment is sufficient to ensure compliance with EC directive 96/29/Euratom for this selected set of radionuclides. (Author) 9 refs

  8. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 - 12.00, and closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  9. Radiation chemical dosimetry by means of nitrate-nitrite

    International Nuclear Information System (INIS)

    Tormo Ferrero, M. J.

    1977-01-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolysis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (Author) 22 refs

  10. Personnel radiation dosimetry laboratory accreditation programme for thermoluminescent dosimeters : a proposal

    International Nuclear Information System (INIS)

    Bhatt, B.C.; Srivastava, J.K.; Iyer, P.S.; Venkatraman, G.

    1993-01-01

    Accreditation for thermoluminescent dosimeters is the process of evaluating a programme intending to use TL personnel dosimeters to measure, report and record dose equivalents received by radiation workers. In order to test the technical competence for conducting personnel dosimetry service as well as to decentralize personnel monitoring service, it has been proposed by Radiological Physics Division (RPhD) to accredit some of the laboratories, in the country. The objectives of this accreditation programme are: (i) to give recognition to competent dosimetry processors, and (ii) to provide periodic evaluation of dosimetry processors, including review of internal quality assurance programme to improve the quality of personnel dosimetry processing. The scientific support for the accreditation programme will be provided by the scientific staff from Radiological Physics Division (RPhD) and Radiation Protection Services Division (RPSD). This paper describes operational and technical requirements for the Personnel Radiation Dosimetry Laboratory Accreditation Programme for Thermoluminescent Dosimeters for Personnel Dosimetry Processors. Besides, many technical documents dealing with the TL Personnel Dosimeter System have been prepared. (author). 5 refs., 2 figs

  11. Apparatus to measure low level helium for neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Shuji; Takao, Yoshiyuki; Muramasu, Masatomo; Hida, Tomoya; Sou, Hirofumi; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori

    1998-03-01

    An apparatus to measure low level helium in a solid sample for neutron dosimetry in the practical use such as area monitoring in the long-term and reactor surveillance was reported. In our previous work, the helium atoms measurement system (HAMS) was developed. A sample was evaporated in the furnace and the released gas from the sample was analyzed with the mass spectrometer of the system to determine the amount of helium contained in it. The system has been improved to advance the lower helium measurement limit in a solid sample for its application to an area monitoring system. The mass of a solid is up to 100mg. Two important points should be considered to advance the lower limit. One was to produce a high quality vacuum in the system chamber for suppressing background gases during the sample measurement. The other important point was to detect very small output from the mass spectrometer. A pulse counting system was used to get high sensitivity in the mass 4 analyzing. (author)

  12. Dosimetry system 1986

    International Nuclear Information System (INIS)

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  13. Dosimetry quality assurance in Martin Marietta Energy Systems' centralized external dosimetry system

    International Nuclear Information System (INIS)

    Souleyrette, M.L.

    1992-01-01

    External dosimetry needs at the four Martin Marietta Energy Systems facilities are served by Energy Systems Centralized External Dosimetry System (CEDS). The CEDS is a four plant program with four dosimeter distribution centers and two dosimeter processing centers. Each plant has its own distribution center, while processing centers are located at ORNL and the Y-12 Plant. The program has been granted accreditation by the Department of Energy Laboratory Accreditation Program (DOELAP). The CEDS is a TLD based system which is responsible for whole-body beta-gamma, neutron, and extremity monitoring. Beta-gamma monitoring is performed using the Harshaw/Solon Technologies model 8805 dosimeter. Effective October 1, 1992 the standard silver mylar has been replaced with an Avery mylar foil blackened on the underside with ink. This was done in an effort to reduce the number of light induced suspect readings. At this time we have little operational experience with the new blackened mylars-The CEDS neutron dosimeter is the Harshaw model 8806B. This card/holder configuration contains two TLD-600/TLD-700 chip pairs; one pair is located beneath a cadmium filter and one pair is located beneath a plastic filter. In routine personnel monitoring the CEDS neutron dosimeter is always paired with a CEDS beta-gamma dosimeter.The CEDS extremity dosimeter is composed of a Harshaw thin TLD-700 dosiclip placed inside a Teledyne RB-4 finger sachet. The finger sachet provides approximately 7 mg/cm 2 filtration over the chip. A teflon ring surrounds the dosiclip to help prevent tearing of the vinyl sachet

  14. Personal Dosimetry in UHC Sestre Milosrdnice: 10-Years Review

    International Nuclear Information System (INIS)

    Bokulic, T.; Budanec, M; Gregov, M.; Kusic, Z.; Mlinaric, M.; Mrcela, I.; Suric Mihic, M.

    2013-01-01

    Personal dose monitoring in UHC 'Sestre milosrdnice' is regulary performed for about 300 exposed workers involved in a variety of tasks with different sources of ionizing radiation. Exposed workers are required to wear personal dosimeters which are read on monthly basis and dose records are kept in the hospital. In this paper an overview of personal dosimetry data from year 2003 till 2013 is presented. Film dosimeters were used for personal dosimetry untill 2010 when the thermoluminescent (TL) dosimetry was introduced. Dosimeters are calibrated to measure personal dose equivalent H p (10). Received doses are analyzed for workers in the field of nuclear medicine, radiotherapy (external beam and brachytherapy), general diagnostic radiology and interventional radiology. Analysis of received doses in the whole period resulted with an average individual dose in nuclear medicine of 0.6 mSv/y, which decreased to 0.21 mSv/y in the last three years, caused by more precise dosimetric methods with TL dosimetry and improved conditions of radiation protection. In the same three-year period, in interventional radiology doses were 0.32 mSv/y, compared to 0.29 mSv/y obtained for a previous seven years. This was expected due to the escalation in a number of interventions and new installed equipment. There was no such difference in diagnostic radiology doses, showing that film dosimetry is suitable for x ray energies. Analysis of all the readings showed a significant influence of measurement procedures on personal dosimeter dose and also the importance of continuous monitoring of the dose records in order to improve the conditions of radiation protection and achieving the ALARA goal.(author)

  15. Development of a Compton camera for online monitoring and dosimetry of laser-accelerated proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Thirolf, Peter G.; Lang, Christian; Aldawood, Saad; Parodi, Katia [LMU Muenchen (Germany); Habs, Dietrich [LMU Muenchen (Germany); MPI fuer Quantenoptik, Garching (Germany); Maier, Ludwig [TU Muenchen (Germany)

    2013-07-01

    A Compton camera is presently under construction in Garching, designed for monitoring and dosimetry of laser-accelerated protons for bio-medical applications via position-resolved prompt γ-ray detection. When ion beams suitable for hadron therapy (protons, carbon ions) interact with tissue (or tissue-equivalent plastic or water phantoms), nuclear reactions induce prompt γ rays that can be utilized, e.g., to verify the ion beam range (i.e. monitor the Bragg peak position) by exploiting the Compton scattering kinematics of these photons. Our Compton camera (formed by a combination of scatter and absorber detector) consists of a stack of six double-sided Si-strip detectors (50 x 50 mm{sup 2}, 0.5 mm thick, 128 strips/side, pitch 390 μm) acting as scatterers, while the absorber is formed by a LaBr{sub 3} scintillator crystal (50 x 50 x 30 mm{sup 3}), read out by a (8 x 8) pixelated multi-anode PMT. Simulation results for design specifications and expected values of resolution and efficiency are presented, as well as the status of the prototype presently under construction.

  16. Reactor Dosimetry State of the Art 2008

    Science.gov (United States)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    Oral session 1: Retrospective dosimetry. Retrospective dosimetry of VVER 440 reactor pressure vessel at the 3rd unit of Dukovany NPP / M. Marek ... [et al.]. Retrospective dosimetry study at the RPV of NPP Greifswald unit 1 / J. Konheiser ... [et al.]. Test of prototype detector for retrospective neutron dosimetry of reactor internals and vessel / K. Hayashi ... [et al.]. Neutron doses to the concrete vessel and tendons of a magnox reactor using retrospective dosimetry / D. A. Allen ... [et al.]. A retrospective dosimetry feasibility study for Atucha I / J. Wagemans ... [et al.]. Retrospective reactor dosimetry with zirconium alloy samples in a PWR / L. R. Greenwood and J. P. Foster -- Oral session 2: Experimental techniques. Characterizing the Time-dependent components of reactor n/y environments / P. J. Griffin, S. M. Luker and A. J. Suo-Anttila. Measurements of the recoil-ion response of silicon carbide detectors to fast neutrons / F. H. Ruddy, J. G. Seidel and F. Franceschini. Measurement of the neutron spectrum of the HB-4 cold source at the high flux isotope reactor at Oak Ridge National Laboratory / J. L. Robertson and E. B. Iverson. Feasibility of cavity ring-down laser spectroscopy for dose rate monitoring on nuclear reactor / H. Tomita ... [et al.]. Measuring transistor damage factors in a non-stable defect environment / D. B. King ... [et al.]. Neutron-detection based monitoring of void effects in boiling water reactors / J. Loberg ... [et al.] -- Poster session 1: Power reactor surveillance, retrospective dosimetry, benchmarks and inter-comparisons, adjustment methods, experimental techniques, transport calculations. Improved diagnostics for analysis of a reactor pulse radiation environment / S. M. Luker ... [et al.]. Simulation of the response of silicon carbide fast neutron detectors / F. Franceschini, F. H. Ruddy and B. Petrović. NSV A-3: a computer code for least-squares adjustment of neutron spectra and measured dosimeter responses / J. G

  17. Application of TL dosimetry in epidemiological studies in HBRAs

    International Nuclear Information System (INIS)

    Chougaonkar, M.P.

    2006-01-01

    Luminescence as a phenomenon has been extensively used in radiation dosimetry, using thermoluminescence. The nuclear industry all over the world over uses TL dosimetry in radiation protection since they have to ensure that the radiation workers and workers involved in industrial applications of radiation sources are not exposed beyond limits set by international monitoring bodies. They have also to ensure that the nuclear applications do not give rise to elevated radiation levels in the environs. In addition, epidemiologists and radiobiologists world over have been working over the past few decades, to study health effects of chronic radiation exposures in populations living in the elevated natural radiation environment. This paper discusses the importance of dosimetric studies, in the normal as well as high background radiation areas (HBRAs), due to the radiation effects on the humans. The application of thermoluminescent dosimeters (TLDs) in population dosimetry with the end point of epidemiological studies is then discussed. The paper outlines the construction of TLDs, methodology of deployment and retrieval and analysis to arrive the dose. To obtain total dose, dosimetric techniques suitable for external gamma radiation, inhalation dose due to radon, thoron and their progenies and radiological analysis of the food items is required. The techniques arriving at the effective dose are outlined. Basics of epidemiological analysis, particularly using case-control methodology and its advantages/ disadvantages are also discussed. Using the previous work by the author, the paper also reviews various analyses that can be carried out the dosimetric data. (author)

  18. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 to 12.00 and is closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  19. Dosimetry and monitoring of thin X-ray beam produced by linear particle accelerator, for application in radiography

    International Nuclear Information System (INIS)

    Campos, J.C.F. de.

    1986-01-01

    The dosimetry and monitoring characteristics of thin X-ray beams, and the application of 4MeV linear particle accelerator to radiosurgery are studied. An addition collimation system, consisted of 3 lead collimators, which allows to obtain thin beams of 6,10 and 15 mm of diameter, was fabricated. The stereo taxic system, together with modifications in dispositives, provide the accuracy required in volum-targed location. The dosimetric informations were determined with silicon detector inserted into water simulator. The isodose curves for each beam, and total isodoses simulating the treatment were established using radiographic emulsions in conditions which reproduce real circunstances of pacient irradiation. (M.C.K.) [pt

  20. Thermoelectric neutron dosimetry: a short introduction

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Debrue, J.; Leonard, F.; Schubert, W.

    1977-01-01

    The paper gives a short introduction and state-of-the-art account of an unconventional, non destructive neutron dosimetry method based on monitoring the neutron fluence dependent changes of the thermoelectric properties of base metals and alloys. The basic principles are exposed and illustrated with experimental data obtained during an exploratory irradiation in the BR2 reactor

  1. Statistics of official personal dosimetry and monitoring activities of the period 1994-1995

    International Nuclear Information System (INIS)

    Boerner, E.; Wittmann, A.; Wahl, W.

    1998-01-01

    The measuring laboratory of the GSF in Neuherberg is the largest of the six official supervisory laboratories in Germany. It distributes the officially approved personal dosemeters and is responsible for personal dosimetry monitoring of about 140,000 persons in the German federal states of Bavaria, Hesse, Schleswig-Holstein, and, since 1989, Baden-Wuerttmeberg. Dosemeter readouts are recorded here in a database together with personal data and data describing activities, so that the information collected can be used as a source of reference for establishing general surveys of occupational exposure to external irradiation with ionizing radiation. The report first describes the dosemeter designs and the methods applied by the GSF lab for quality assurance, then explains results of the statistical evaluation of the recent data from 1994-1995, and concludes with explaining tendencies shown by long-term curves of the collective and average annual doses recorded in the years from 1986 until 1995. (orig./CB) [de

  2. Dosimetry in life sciences

    International Nuclear Information System (INIS)

    1975-01-01

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  3. Dosimetry in life sciences

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-06-15

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  4. Radiation protection dosimetry in medicine - Report of the working group n.9 of the European radiation dosimetry group (EURADOS) - coordinated network for radiation dosimetry (CONRAD - contract EC N) fp6-12684; Dosimetrie pour la radioprotection en milieu medical - rapport du groupe de travail n. 9 du European radiation dosimetry group (EURADOS) - coordinated netword for radiation dosimetry (CONRAD - contrat CE fp6-12684)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This report present the results achieved within the frame of the work the WP 7 (Radiation Protection Dosimetry of Medical Staff) of the coordination action CONRAD (Coordinated Network for Radiation Dosimetry) funded through the 6. EU Framework Program. This action was coordinated by EURADOS (European Radiation Dosimetry Group). EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. WP7 coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated through sub-groups covering three specific areas: 1. Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2. Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons in large exposure during interventional radiology procedures, especially to determine effective doses to cardiologists during cardiac catheterization; and 3. Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (authors)

  5. Dosimetry and operation of irradiation facilities

    International Nuclear Information System (INIS)

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  6. Collection of abstracts. 6. national symposium on radiation dosimetry

    International Nuclear Information System (INIS)

    1983-08-01

    Abstracts are given of the total of 137 papers presented at the symposium. The papers discussed radiation dosimetry methods, dosemeters and detectors, the metrology and calibration of radiation sources, calibration standards, and radioactivity monitoring. (J.P.)

  7. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual Dosimetry ServiceWe inform all staffs and users under regular dosimetric control that the dosimeters for the monitoring period JULY/AUGUST are available from their usual dispatchers.Please have your films changed before the 10th of July.The colour of the dosimeter valid in JULY/AUGUST is PINK.

  8. Heavy-ion dosimetry

    International Nuclear Information System (INIS)

    Schimmerling, W.

    1980-03-01

    This lecture deals with some of the more important physical characteristics of relativistic heavy ions and their measurement, with beam delivery and beam monitoring, and with conventional radiation dosimetry as used in the operation of the BEVALAC biomedical facility for high energy heavy ions (Lyman and Howard, 1977; BEVALAC, 1977). Even so, many fundamental aspects of the interaction of relativistic heavy ions with matter, including important atomic physics and radiation chemical considerations, are not discussed beyond the reminder that such additional understanding is required before an adequte perspective of the problem can be attained

  9. Patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Shrimpton, P.C.

    2000-01-01

    Full text: X-ray examinations remain an essential and widely used diagnostic tool in medicine and hence the most significant source of exposure to man-made radiation for populations. Patterns of practice in diagnostic radiology continue to evolve, with overall growth in the numbers of procedures worldwide and, particularly in developed countries, increasing importance for complex procedures such as computed tomography (CT) and interventional techniques. In order to maximise the benefits from x-rays relative to the associated radiation risks, there is a need to ensure the prior justification of all examinations and the optimisation of patient protection such that doses are as low as reasonably practicable to meet specific clinical requirements. Accordingly, patient dosimetry is a fundamental requirement in diagnostic radiology. Detailed measurements for the assessment of risks or comparison of different types of procedure require the estimation of organ and effective doses. Such comprehensive dosimetry necessarily involves the simulation of clinical practice using anthropomorphic phantoms, with either measurements in a physical phantom or calculations utilising a mathematical phantom. Simpler measurements for the routine monitoring of dose in x-ray departments can be based on practical quantities such as entrance surface dose, dose-area product and, for CT, weighted CT dose index and dose-length product. Widescale surveys reveal significant variations between departments in the typical doses for a given type of procedure and potential scope for dose reductions. In order to promote improvements in practice, the results of periodic dose surveys in departments should be compared with appropriate standards, such as diagnostic reference levels for adult and paediatric patients, that are set nationally or locally for the purposes of promoting critical review of the equipment and techniques in use. Patient dosimetry should form an essential element of routine quality

  10. Proceedings of the recent developments in radiation dosimetry

    International Nuclear Information System (INIS)

    Bhat, Nagesh; Palani Selvan, T.

    2016-01-01

    Whilst 'Dosimetry' in its original sense deals with methods for a quantitative determination of energy deposited in a given medium by directly or indirectly ionizing radiations, the term is better known as a scientific sub-specialty in the fields of health physics and medical physics, where it is the calculation and assessment of the radiation dose received by the human body. Dosimetry is used extensively for radiation protection and is routinely applied to ensure radiological safety of occupational radiation workers. Internal dosimetry due to the ingestion or inhalation of radioactive materials relies on a variety of physiological or imaging techniques. External dosimetry, due to irradiation from an external source is based on measurements with a dosimeter, or inferred from other radiological protection instruments. Radiation dosimetry is one of the important research areas of Department of Atomic Energy (DAE). This research work is centered on the facilities such as nuclear reactors, reprocessing plants, high energy accelerators (research/industry/medical), radiation standards, food processing, radiation technology development, etc. In each of these facilities, radiation field environment is different and the associated dosimetry concepts are different. Papers relevant to INIS are indexed separately

  11. NOTE FROM THE DOSIMETRY SERVICE

    CERN Multimedia

    2002-01-01

    During March, the Dosimetry Service will be opened from 8h30 to 12h in the morning and closed every afternoon.   We have established that many people, who are provided regularly with a personal dosimeter (film badge), have changed their activity and do not need it anymore, because they do not, or only exceptionally, enter controlled areas. If you are one of these persons, please contact the Personal Dosimeter Service (tel: 72155). There is a simplified procedure for obtaining a dosimeter if you have an immediate need for short-term visits in controlled areas. A reduction of the number of persons on the regular distribution list of dosimeters would decrease our and the distributors workload. It would also contribute to significant savings in the dosimetry, and thus CERN, budget. We thank you in advance for your understanding and for your collaboration.

  12. Personal dosimetric monitoring in Ukraine: current status and further development

    International Nuclear Information System (INIS)

    Chumak, V. V.; Musijachenkom, A. V.; Boguslavskaya, A. I.

    2003-01-01

    Presently Ukraine has mixed system for dosimetric monitoring. Nuclear power plants and some major nuclear facilities have their own dosimetry services, which are responsible for regular dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by dosimetry laboratories affiliated to the territorial authorities for sanitary and epidemiology supervision. In 2002-2003 Ukrainian Ministry of Health performed survey of the status of dosimetric monitoring and inventory of critical groups requiring such monitoring. Dosimetry services in Ukraine cover about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca.12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services operate in 13 of 24 regions of Ukraine, using DTU-01 manual TLD readers produced with one exception in 1988-1990. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38% to 100% depending on the region. Personnel of nuclear power plants (about 16,400 workers) is monitored by their own dosimetry services achieving absolute coverage of the main staff and temporary workers. Current inadequate status of dosimetric monitoring infrastructure in Ukraine demands an urgent elaboration of the united state system for monitoring and recording of individual doses. The proposed plan would allows to bring dosimetry infrastructure in Ukraine to the modern state which would be compatible with existing and future European and international radiation protection networks. Unitary structure of Ukraine, strong administrative command and good communications between regions of the country are positive factors in favour of efficient implementation of the proposed plan. Deficiencies are associated with limited funding of this effort. (authors)

  13. Wide-area, real-time monitoring and visualization system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  14. Dosimetry of internal emitters - quo vadis?

    International Nuclear Information System (INIS)

    Reddy, A.R.; Nagaratnam, A.; Jain, S.C.; Gupta, M.M.; Mehta, S.C.

    1999-01-01

    The dosimetry of internally administered radiopharmaceuticals in nuclear medicine procedures using MIRD formalisms and dosimetry in the case of intakes of radionuclides and ICRP methodology for the purpose of radiological protection are well established working practices. It should, however, be remembered that dose or dose coefficients calculated refer to a reference individual, defined in terms of a mathematical phantom established on the basis of certain biokinetic reference parameters. The reference individual represents a typical caucasian adult of West Europe or North American origin. Recently, some attempts have been made to define a Reference Asian and a Reference Indian individual and to assess the effects of anatomical differences and changes in the biokinetics of radiopharmaceuticals and other radionuclides in these different reference individuals on the estimation of dose and dose coefficients in relation to the intake of internal radionuclides. The assessment of doses to the embryo/fetus due to intake of radionuclides by pregnant women, local dose estimates, microdosimetry, radiobiology and radiation protection aspects relating to Auger electron emitters represent other areas of active research in the area of dosimetry of internal emitters. The present review summarises these different aspects of work. (orig.) [de

  15. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  16. Dosimetry

    International Nuclear Information System (INIS)

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  17. External dosimetry sources and shielding

    International Nuclear Information System (INIS)

    Calisto, Washington

    1994-01-01

    A definition of external dosimetry r external sources dosimetry,physical and mathematical treatment of the interaction of gamma radiation with a minimal area in that direction. Concept of attenuation coefficient, cumulated effect by polyenergetic sources, exposition rate, units, cumulated dose,shielding, foton shielding, depth calculation, materials used for shielding.Beta shielding, consideration of range and maximum β energy , low stopping radiation by use of low Z shielding. Tables for β energy of β emitters, I (tau) factor, energy-range curves for β emitters in aqueous media, gamma attenuation factors for U, W and Pb. Y factor for bone tissue,muscle and air, build-up factors

  18. The new area monitoring system and the fuel database of the TRIGA Mark II reactor in Vienna

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Hofbauer, M.; Schwarz, V.

    2004-01-01

    The 250 kW TRIGA Mark-II reactor operates since March 1962 at the Atominstitut, Vienna, Austria. Its main tasks are nuclear education and training in the fields of neutron- and solid state physics, nuclear technology, reactor safety, radiochemistry, radiation protection and dosimetry, and low temperature physics and fusion research. Academic research is carried out by students in the above mentioned fields coordinated and supervised by about 70 staff members with the aim of a masters- or PhD degree in one of the above mentioned areas. After 25 years of successful operation, it was necessary to exchange the old area monitoring system with a new digital one. The purpose of the new system is the permanent control of the reactor hall, the primary and secondary cooling system and the monitoring of the ventilation system. The paper describes the development and implementation of the new area monitoring system. The second topic in this paper describes the development of the new fuel database. Since March 7th, 1962, the TRIGA Mark II reactor Vienna operates with an average of 263 MWh per year, which corresponds to a uranium burn-up of 13.7 g per year. Presently we have 81 TRIGA fuel elements in the core, 55 of them are old aluminium clad elements from the initial criticality while the rest are stainless steel clad elements which had been added later to compensate the uranium consumption. Because 67 % of the elements are older than 40 years, it was necessary to put the history of every element in a database, to get an easy access to all the relevant data for every element in our facility. (author)

  19. Radiation protection of medical staff: a coordinated action by EURADOS on extremely dosimetry and the use of active personnel dosemeters (CONRAD)

    International Nuclear Information System (INIS)

    Struelens, L.; Vanhavere, F.

    2009-01-01

    Monitoring of workers constitutes an integral part of any radiological protection program. However, unresolved issues in radiation protection of medical staff still remain. Research and establishment of guidelines are necessary on a variety of issues such as extremity dosimetry (fingers, eye lenses, etc), the use of double dosimetry above and below lead aprons, or the use of electronic personal dosimeters in interventional procedures. Medical practices are also evolving fast, and new techniques with ionising radiation emerge very regularly, thus implying the need of radiation protection measures for medical staff, and the implementation of new monitoring programs. In some medical applications of radiation there is an increased risk of high local exposures because of direct handling of sources or the use of beta-emitters. However, despite the large number of workers that are exposed in the medical field worldwide, only few measurements of extremity doses have been reported in the literature. Some activities of EURADOS Working Group 9 (WG9) were sponsored by the European Commission in the CONRAD project. This CONRAD project was aiming at the coordination of research on radiation protection at the workplace. Working group 9 has been involved in the coordination and promotion of European research in the field of Radiation Protection Dosimetry for Medical Staff. One of the objectives of this working group was to formulate the state of the art and to identify areas in which improvements were needed. For some of these medical applications the skin of the fingers is the limiting organ from the point of view of individual monitoring of external radiation. The wide variety of radiation field characteristics in a medical environment, and the difficulty of measuring a local dose that is representative for the maximum skin dose (usually with one single detector), makes it difficult to perform extremity dosimetry with an accuracy similar to whole-body dosimetry. Therefore a

  20. The personal dosimetry in Mexico; La dosimetria personal en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A. [Proxtronics/ Asesoria Integral en Dosimetria Termoluminiscente S.A. de C.V., Canal de Miramontes 2030-14, Col. Educacion, 04400 Mexico D.F. (Mexico)]. e-mail: aidtsa@avantel.net

    2006-07-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  1. Dosimetry with the scanned proton beam on the PSI gantry

    International Nuclear Information System (INIS)

    Coray, A.; Pedroni, E.; Boehringer, T.; Lin, S.; Lomax, T.; Goitein, G.

    2002-01-01

    Full text: The irradiation facility at PSI is designed for the treatment of deep seated tumours with a proton beam energy of up to 270 MeV. The spot scanning technique, which uses a proton pencil beam applied to the patient, is performed on a compact isocentric gantry. An optimal three-dimensional conformation of the dose distribution to the target volume can be realized. A fast steering system and a redundant interlock system are in operation. The dose delivery is controlled by a parallel plate transmission chamber, which is calibrated in terms of number of protons per monitor unit. The therapy planning is based on an empirical model, which takes into account attenuation of primary protons and losses outside the primary beam through secondary products. The therapy plan predicts an absolute dose. The calibration of the primary monitor is done using a reference thimble ionization chamber inside a homogeneous geometrical dose volume. The reference system is calibrated in a cobalt field at the national office of metrology in terms of absorbed dose to water. The dosimetry protocol used up to last year was based on the ICRU Report Nr. 59, we have switched to the IAEA Code of Practice starting this beam period. Data on the monitor calibration for various energies and using two different reference systems will be shown. The calibration of the beam monitor using a Faraday Cup in the static pencil beam results in a good agreement with the ionization chamber measurements, with a deviation of less than 1%. Following the daily setup of the machine, an extensive quality control and safety check of the whole system is performed. The daily dosimetry quality assurance program includes: measurement of dose rate and monitor ratios; check of the beam position monitors; measurement of a depth dose curve; dose measurement in a regular dose field. The doses measured daily in a regular scanned field show a standard deviation of about 1 %. Further daily checks results, which illustrate

  2. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011

    International Nuclear Information System (INIS)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia

    2013-01-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements

  3. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  4. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

    Directory of Open Access Journals (Sweden)

    HosseiniAliabadi S. J.

    2015-06-01

    Full Text Available Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion: This system can be utilized in large scale environmental monitoring with a higher accuracy

  5. Radiation protection dosimetry in medicine - Report of the working group n.9 of the European radiation dosimetry group (EURADOS) - coordinated network for radiation dosimetry (CONRAD - contract EC N) fp6-12684

    International Nuclear Information System (INIS)

    2009-01-01

    This report present the results achieved within the frame of the work the WP 7 (Radiation Protection Dosimetry of Medical Staff) of the coordination action CONRAD (Coordinated Network for Radiation Dosimetry) funded through the 6. EU Framework Program. This action was coordinated by EURADOS (European Radiation Dosimetry Group). EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. WP7 coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated through sub-groups covering three specific areas: 1. Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2. Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons in large exposure during interventional radiology procedures, especially to determine effective doses to cardiologists during cardiac catheterization; and 3. Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (authors)

  6. Personnel radiation dosimetry

    International Nuclear Information System (INIS)

    1987-01-01

    The book contains the 21 technical papers presented at the Technical Committee Meeting to Elaborate Procedures and Data for the Intercomparison of Personnel Dosimeters organizaed by the IAEA on 22-26 April 1985. A separate abstract was prepared for each of these papers. A list of areas in which additional research and development work is needed and recommendations for an IAEA-sponsored intercomparison program on personnel dosimetry is also included

  7. Clinical dosimetry with plastic scintillators - Almost energy independent, direct absorbed dose reading with high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Fluehs, D [Department of Radiotherapy, Essen (Germany). Div. of Clinical Radiation Physics; Fluehs, D; Kolanoski, H [Dortmund Univ. (Germany). Inst. fuer Physik

    1996-08-01

    Clinical dosimetry is still far behind the goal to measure any spatial or temporal distribution of absorbed dose fast and precise without disturbing the physical situation by the dosimetry procedure. NE 102A plastic scintillators overcome this border. These tissue substituting dosemeter probes open a wide range of new clinical applications of dosimetry. This versatile new dosimetry system enables fast measurement of the absorbed dose to water in water also in regions with a steep dose gradient, close to interfaces, or in partly shielded regions. It allows direct reading dosimetry in the energy range of all clinically used external photon and electron beams, or around all branchytherapy sources. Thin detector arrays permit fast and high resolution measurements in quality assurance, such as in-vivo dosimetry or even afterloading dose monitoring. A main field of application is the dosimetric treatment planning, the individual optimization of brachytherapy applicators. Thus, plastic scintillator dosemeters cover optimally all difficult fields of clinical dosimetry. An overview about its characteristics and applications is given here. 20 refs, 1 fig.

  8. Trends of personal dosimetry at atomic power plants

    International Nuclear Information System (INIS)

    Yamamura, Seini

    1998-01-01

    The individual dosimetry at the atomic power station is sorted for monthly dosimetry, daily dosimetry and special job dosimetry in high dose circumstance. Film badge (passive dosimeter) can measure gamma dose, beta dose and neutron dose respectively lower than about 0.1 mSv. While workers are in the radiation controlled area, they have to wear the dosimeters and the individual dose is accumulated for every one month. Recently the Silicon semiconductors detecting beta ray and neutron have been developed. With microcircuit technology and these new sensors, new multiple function dosimeter of the card size had been put to practical use. The result of dose measurement obtained by the electronic dosimeter is consistent well with the measurement of usual film badge and new dosimeter can determine the dose as low as 0.01 mSv. The result is stored in the non-volatile memory in the electronic personal dosimeter and held for more than one year without the power supply. The function to read data directly from the memory improves the reliability of the data protection. The realization of the unified radiation control system that uses the electronic personal dosimeter for monthly dosimetry is expected. (J.P.N.)

  9. Internal sources dosimetry

    International Nuclear Information System (INIS)

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  10. Application of EGS and ETRAN to Problems in Medical Physics and Dosimetry

    CERN Document Server

    Nelson, W R

    1980-01-01

    The author looks at a few applications of Monte Carlo programs to problems of interest in medical physics and dosimetry. In particular, two areas are considered: 1) bremsstrahlung production from medical accelerators; 2) photon dosimetry at medium to low energies. (16 refs) .

  11. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  12. NRPB patient dosimetry service

    International Nuclear Information System (INIS)

    Shrimpton, P.; Hillier, M.; Bungay, D.; Wall, B.

    1994-01-01

    For nearly 20 years, thermoluminescent dosemeters (TLDs) have been used by NRPB to investigate the doses received by patients undergoing diagnostic examinations with x-rays, and these measurements have formed the basis for national recommendations on patient protection. Monitoring typical levels of patient dose should represent an essential element of routine quality assurance in x-ray departments. In order to promote more widespread measurements in hospitals, NRPB has drawn on a wealth of experience to establish a high-quality service providing TLDs for medical dosimetry by post. (author)

  13. Use of the GATE Monte Carlo package for dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Visvikis, D. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France)]. E-mail: Visvikis.Dimitris@univ-brest.fr; Bardies, M. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Chiavassa, S. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Danford, C. [Department of Medical Physics, MSKCC, New York (United States); Kirov, A. [Department of Medical Physics, MSKCC, New York (United States); Lamare, F. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France); Maigne, L. [Departement de Curietherapie-Radiotherapie, Centre Jean Perrin, F 63000 Clemont-Ferrand (France); Staelens, S. [UGent-ELIS, St-Pietersnieuwstraat, 41, B 9000 Gent (Belgium); Taschereau, R. [CRUMP Institute for Molecular Imaging, UCLA, Los Angeles (United States)

    2006-12-20

    One of the roles for Monte Carlo (MC) simulation studies is in the area of dosimetry. A number of different codes dedicated to dosimetry applications are available and widely used today, such as MCNP, EGSnrc and PTRAN. However, such codes do not easily facilitate the description of complicated 3D sources or emission tomography systems and associated data flow, which may be useful in different dosimetry application domains. Such problems can be overcome by the use of specific MC codes such as GATE (GEANT4 Application to Tomographic Emission), which is based on Geant4 libraries, providing a scripting interface with a number of advantages for the simulation of SPECT and PET systems. Despite this potential, its major disadvantage is in terms of efficiency involving long execution times for applications such as dosimetry. The strong points and disadvantages of GATE in comparison to other dosimetry specific codes are discussed and illustrated in terms of accuracy, efficiency and flexibility. A number of features, such as the use of voxelised and moving sources, as well as developments such as advanced visualization tools and the development of dose estimation maps allowing GATE to be used for dosimetry applications are presented. In addition, different examples from dosimetry applications with GATE are given. Finally, future directions with respect to the use of GATE for dosimetry applications are outlined.

  14. Worldwide QA networks for radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Svensson, H.; Ibbott, G.

    2002-01-01

    A number of national or international organizations have developed various types and levels of external audits for radiotherapy dosimetry. There are three major programmes who make available external audits, based on mailed TLD (thermoluminescent dosimetry), to local radiotherapy centres on a regular basis. These are the IAEA/WHO TLD postal dose audit service operating worldwide, the European Society for Therapeutic Radiology and Oncology (ESTRO) system, EQUAL, in European Union (EU) and the Radiological Physics Center (RPC) in North America. The IAEA, in collaboration with WHO, was the first organization to initiate TLD audits on an international scale in 1969, using mailed system, and has a well-established programme for providing dose verification in reference conditions. Over 32 years, the IAEA/WHO TLD audit service has checked the calibration of more than 4300 radiotherapy beams in about 1200 hospitals world-wide. Only 74% of those hospitals who receive TLDs for the first time have results with deviation between measured and stated dose within acceptance limits of ±5%, while approximately 88% of the users that have benefited from a previous TLD audit are successful. EQUAL, an audit programme set up in 1998 by ESTRO, involves the verification of output for high energy photon and electron beams, and the audit of beam parameters in non-reference conditions. More than 300 beams are checked each year, mainly in the countries of EU, covering approximately 500 hospitals. The results show that although 98% of the beam calibrations are within the tolerance level of ±5%, a second check was required in 10% of the participating centres, because a deviation larger than ±5% was observed in at least one of the beam parameters in non-reference conditions. EQUAL has been linked to another European network (EC network) which tested the audit methodology prior to its application. The RPC has been funded continuously since 1968 to monitor radiation therapy dose delivery at

  15. Review of radiation dosimetry research at the University of Wisconsin during 1961-1982

    International Nuclear Information System (INIS)

    Cameron, J.R.; Moran, P.R.; Attix, F.H.

    1982-01-01

    The report provides a comprehensive review of the overall activities in this program since 1961. Research areas have included the development and use of lithium fluoride for thermoluminescent dosimetry, solid state neutron dosimetry, and ionization chamber research

  16. Secondary standard dosimetry laboratory Saraykoy Nuclear Research and Training Center Ankara, Turkey

    International Nuclear Information System (INIS)

    Okruhlica, P.

    2014-01-01

    Turkish Saraykoy Nuclear Research and Training Center (SANA) was founded in 2005. In 2014 the company PTW Freiburg in cooperation with VF Cerna Hora started the construction of a comprehensive national metrology laboratories of ionizing radiation 'Secondary Standard Dosimetry Laboratory' (SSDL). The laboratory will be located in the area of 'Saraykoy Nuclear Research and Training Center' in Ankara in Turkey. SSDL will be equipped with metrology departments for calibration and measurement of standard required quantities of metrology of ionizing radiation: - Neutron workplace; Gamma workplace (low-energy X-ray, gamma Standard Cs-137 and high dose rate, Co-60); - Beta workplace; - Control system of metrology laboratories and irradiation VF DARS; - Radiation monitoring system VF RMS; - Camera and security system; - Measuring instruments (ionization chambers, electrometers, monitors for environmental measurements ...) with the appropriate phantoms and other systems.

  17. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  18. Technical basis document for internal dosimetry

    International Nuclear Information System (INIS)

    Hickman, D.P.

    1991-01-01

    This document provides the technical basis for the Chem-Nuclear Geotech (Geotech) internal dosimetry program. Geotech policy describes the intentions of the company in complying with radiation protection standards and the as low as reasonably achievable (ALARA) program. It uses this policy and applicable protection standards to derive acceptable methods and levels of bioassay to assure compliance. The models and computational methods used are described in detail within this document. FR-om these models, dose- conversion factors and derived limits are computed. These computations are then verified using existing documentation and verification information or by demonstration of the calculations used to obtain the dose-conversion factors and derived limits. Recommendations for methods of optimizing the internal dosimetry program to provide effective monitoring and dose assessment for workers are provided in the last section of this document. This document is intended to be used in establishing an accredited dosimetry program in accordance with expected Department of Energy Laboratory Accreditation Program (DOELAP) requirements for the selected radionuclides provided in this document, including uranium mill tailing mixtures. Additions and modifications to this document and procedures derived FR-om this document are expected in the future according to changes in standards and changes in programmatic mission

  19. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  20. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  1. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  2. The work of the 'Irradiation Damage' sub-group of the EURATOM Working Group on Research Reactor Dosimetry

    International Nuclear Information System (INIS)

    Genthon, J.P.

    1975-01-01

    The EURATOM Working Group on Reactor Dosimetry is investigating the problems of the dosimetry of radiation damage experiments. Papers have been published on the dosimetry of graphite and irradiation of metals: the model chosen, the quantities employed to express the fluences, numerical values, measurements, and measurement techniques. The ensuing work of the EURATOM Working Group of Reactor Dosimetry in these areas will deal with the measurement methods required for the dosimetry of radiation damage. (Auth.)

  3. Radiation protection dosimetry and calibrations

    International Nuclear Information System (INIS)

    Verhavere, Ph.

    2007-01-01

    At the SCK-CEN different specialised services are delivered for a whole range of external and internal customers in the radiation protection area. For the expertise group of radiation protection dosimetry and calibrations, these services are organized in four different laboratories: dosimetry, anthropogammametry, nuclear calibrations and non-nuclear calibrations. The services are given by a dedicated technical staff who has experience in the handling of routine and specialised cases. The scientific research that is performed by the expertise group makes sure that state-of-the-art techniques are being used, and that constant improvements and developments are implemented. Quality Assurance is an important aspect for the different services, and accreditation according national and international standards is achieved for all laboratories

  4. X-ray area monitor

    International Nuclear Information System (INIS)

    Nintrakit, N.

    1983-01-01

    The X-ray area monitor is a nuclear electronic device that is essential in radiation protection in high radiation laboratories, e.g. in medical diagnosis using X-rays and in industrial X-radiography. Accidentally the level of X-radiator may arise above the safe permissible level and in such a case the alarm system of the area monitor will work and disconnect the ac power supply form the X-ray unit. Principally the device is a radiation counter using G.M.tube as radiation detector with high voltage supply variable form 200 to 2,000 volts. The maximum count rate of the scaler is 1.5 MHz and the total count is displayed on 4 digit LED's. A time base is used to control the counting time, the frequency multiplier, radiation safety limit, comparator and the radiation hazard warning signal. The reliability of the instrument is further enhanced through the addition of the random correction circuit, and it is applicable both in X- and γ -radiation

  5. Technical basis document for internal dosimetry

    CERN Document Server

    Hickman, D P

    1991-01-01

    This document provides the technical basis for the Chem-Nuclear Geotech (Geotech) internal dosimetry program. Geotech policy describes the intentions of the company in complying with radiation protection standards and the as low as reasonably achievable (ALARA) program. It uses this policy and applicable protection standards to derive acceptable methods and levels of bioassay to assure compliance. The models and computational methods used are described in detail within this document. FR-om these models, dose- conversion factors and derived limits are computed. These computations are then verified using existing documentation and verification information or by demonstration of the calculations used to obtain the dose-conversion factors and derived limits. Recommendations for methods of optimizing the internal dosimetry program to provide effective monitoring and dose assessment for workers are provided in the last section of this document. This document is intended to be used in establishing an accredited dosi...

  6. Dosimetry of beams for negative pi-meson radiation therapy

    International Nuclear Information System (INIS)

    Dicello, J.F.

    1976-01-01

    Several new facilities have been built in the last few years which can produce high intensity beams of pions. As a result, a significant amount of new data related to pion dosimetry is available. Results of beam composition, beam shaping, and collimation are given along with depth dose curves and isodose contours. Experimental data which describe the radiation quality of pion beams and the change in radiation quality with position are presented. Experimental data determining the fraction of the dose resulting from neutrons are discussed. The present techniques used in pion dosimetry are summarized, and those areas of pion dosimetry which require additional effort in order to achieve routine treatment planning for patients are reviewed

  7. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  8. Radiation protection and monitoring

    International Nuclear Information System (INIS)

    Thomas, P.

    1982-01-01

    The present paper deals with the following topics: - Radiological quantities and units - Principles of radiological protection - Limits of doses and activity uptake - Activity discharges and monitoring - Radiation exposure and its calculation - Environmental monitoring - Personnel dosimetry. (orig./RW)

  9. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  10. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  11. CIEMAT external dosimetry service: ISO/IEC 17025 accreditation and 3 y of operational experience as an accredited laboratory

    International Nuclear Information System (INIS)

    Romero, A.M.; Rodriguez, R.; Lopez, J.L.; Martin, R.; Benavente, J.F.

    2016-01-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. (authors)

  12. Bayesian Methods for Radiation Detection and Dosimetry

    CERN Document Server

    Groer, Peter G

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed comp...

  13. Radiation processing dosimetry - past, present and future

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1999-01-01

    Since the two United Nations Conferences were held in Geneva in 1955 and 1958 on the Peaceful Uses of Atomic Energy and the concurrent foundation of the International Atomic Energy Agency in 1957, the IAEA has fostered high-dose dosimetry and its applications. This field is represented in industrial radiation processing, agricultural programmes, and therapeutic and preventative medicine. Such dosimetry is needed specifically for pest and quarantine control and in the processing of medical products, pharmaceuticals, blood products, foodstuffs, solid, liquid and gaseous wastes, and a variety of useful commodities, e.g. polymers, composites, natural rubber and elastomers, packaging, electronic, and automotive components, as well as in radiotherapy. Improvements and innovations of dosimetry materials and analytical systems and software continue to be important goals for these applications. Some of the recent advances in high-dose dosimetry include tetrazolium salts and substituted polydiacetylene as radiochromic media, on-line real-time as well as integrating semiconductor and diamond-detector monitors, quantitative label dosimeters, photofluorescent sensors for broad dose range applications, and improved and simplified parametric and computational codes for imaging and simulating 3D radiation dose distributions in model products. The use of certain solid-state devices, e.g. optical quality LiF, at low (down to 4K) and high (up to 500 K) temperatures, is of interest for materials testing. There have also been notable developments in experimental dose mapping procedures, e.g. 2D and 3D dose distribution analyses by flat-bed optical scanners and software applied to radiochromic and photofluorescent images. In addition, less expensive EPR spectrometers and new EPR dosimetry materials and high-resolution semiconductor diode arrays, charge injection devices, and photostimulated storage phosphors have been introduced. (author)

  14. Biological monitoring of radiation exposure

    Science.gov (United States)

    Horneck, G.

    1998-11-01

    Complementary to physical dosimetry, biological dosimetry systems have been developed and applied which weight the different components of environmental radiation according to their biological efficacy. They generally give a record of the accumulated exposure of individuals with high sensitivity and specificity for the toxic agent under consideration. Basically three different types of biological detecting/monitoring systems are available: (i) intrinsic biological dosimeters that record the individual radiation exposure (humans, plants, animals) in measurable units. For monitoring ionizing radiation exposure, in situ biomarkers for genetic (e.g. chromosomal aberrations in human lymphocytes, germ line minisatellite mutation rates) or metabolic changes in serum, plasma and blood (e.g. serum lipids, lipoproteins, lipid peroxides, melatonin, antibody titer) have been used. (ii) Extrinsic biological dosimeters/indicators that record the accumulated dose in biological model systems. Their application includes long-term monitoring of changes in environmental UV radiation and its biological implications as well as dosimetry of personal UV exposure. (iii) Biological detectors/biosensors for genotoxic substances and agents such as bacterial assays (e.g. Ames test, SOS-type test) that are highly sensitive to genotoxins with high specificity. They may be applicable for different aspects in environmental monitoring including the International Space Station.

  15. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  16. Design of movable fixed area γ dose rate monitor

    International Nuclear Information System (INIS)

    Li Dongyu; Cheng Wen; Li Jikai; Huang Hong; Shen Qiming; Zhang Qiang; Liu Zhengshan

    2005-10-01

    Movable fixed area γ dose rate monitor has not only the characteristics of fixed area γ dose rate monitor, but that of portable meter as well. Its main function is to monitor the areas where dose rate would change without orderliness to prevent unplanned radiation exposure accidents from happening. The design way of the monitor, the main indicators description, the working principle and the comprising of software and hardware are briefly introduced. The monitor has the characteristics of simple installation, easy maintenance, little power consumption, wide range, notability of visual and audible alarm and so on. Its design and technique have novelty and advancement. (authors)

  17. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    International Nuclear Information System (INIS)

    2002-01-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in 60 Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and satisfies

  18. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in {sup 60}Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and

  19. Tritium dosimetry and standardization

    International Nuclear Information System (INIS)

    Balonov, M.I.

    1983-01-01

    Actual problem of radiation hygiene such as an evaluation of human irradiation hazard due to a contact with tritium compounds both in industrial and public spheres is under discussion. Sources of tritium release to environment are characterized. Methods of tritium radiation monitoring are discussed. Methods of dosimetry of internal human exposure resulted from tritium compounds are developed on the base of modern representations on metbolism and tritium radiobiological effect. A system of standardization of permissible intake of tritium compounds for personnel and persons of population is grounded. Some protection measures are proposed as applied to tritium overdosage

  20. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  1. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  2. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  3. International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS). Book of Extended Synopses

    International Nuclear Information System (INIS)

    2010-01-01

    The major goal of the symposium is to provide a forum where advances in radiation dosimetry during the last decade, in radiation medicine and radiation protection can be disseminated and scientific knowledge exchanged. It will include all specialties in radiation medicine and radiation protection dosimetry with a specific focus on those areas where the standardization of dosimetry has improved in the recent years (brachytherapy, diagnostic radiology and nuclear medicine). It will also summarize the present status and outline future trends in medical radiation dosimetry and identify possible areas for improvement. Its conclusions and summaries should lead to the formulation of recommendations for the scientific community

  4. International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS). Book of Extended Synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The major goal of the symposium is to provide a forum where advances in radiation dosimetry during the last decade, in radiation medicine and radiation protection can be disseminated and scientific knowledge exchanged. It will include all specialties in radiation medicine and radiation protection dosimetry with a specific focus on those areas where the standardization of dosimetry has improved in the recent years (brachytherapy, diagnostic radiology and nuclear medicine). It will also summarize the present status and outline future trends in medical radiation dosimetry and identify possible areas for improvement. Its conclusions and summaries should lead to the formulation of recommendations for the scientific community

  5. EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS.

    Science.gov (United States)

    Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim; Simon, Steven L

    2007-07-01

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed "accident doses", were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy.

  6. EPR tooth dosimetry of SNTS area inhabitants

    Energy Technology Data Exchange (ETDEWEB)

    Sholom, Sergey [Scientific Center for Radiation Medicine, Melnikova str., 53, Kiev (Ukraine); Desrosiers, Marc [Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD (United States); Bouville, Andre; Luckyanov, Nicholas [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, 6120 Executive Boulevard, Bethesda, MD (United States); Chumak, Vadim [Scientific Center for Radiation Medicine, Melnikova str., 53, Kiev (Ukraine); Simon, Steven L. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, 6120 Executive Boulevard, Bethesda, MD (United States)], E-mail: ssimon@mail.nih.gov

    2007-07-15

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed 'accident doses', were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine settlements were in the range from a few tens of mGy to approximately 100 mGy.

  7. Official dosimetry with individual electronic dosemeters - the concept in Germany

    International Nuclear Information System (INIS)

    Czarwinski, R.; Kaulard, J.; Pfeffer, W.

    2005-01-01

    Full text: Presently, in Germany passive dosemeters (film batches, RPL, TLD) are used for the official individual monitoring of occupational exposed personal. The application of electronic individual dosemeters (EPD) is carried out mainly for the operative radiation protection control particularly in nuclear power engineering companies, big hospitals und research centres. This means in such institutions double monitoring exists - legally and operatively. A crucial advantage of EPD compared to passive dosemeter is the possibility to adapt the monitoring period to the working time in the control area, e.g. a job related monitoring is available. Germany started a project for an optimized implementation of EPD into the official dosimetry. Objective of the project whose results will be described in the paper is the harmonization of radiation protection of companies workers and outside workers concerning the record of individual and job related exposures. The approval of the EPD by the Federal and Laender authorities as an official dosimetric system demands the implementation of special requirements concerning the data acquisition, data transfer and data evaluation. These issues are focuses of the Federal research project, supervised by the Federal Office for Radiation Protection (BfS) and performed by the Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS), Cologne to develop a concept in the first stage. (author)

  8. INTEGRATED OPERATIONAL DOSIMETRY SYSTEM AT CERN.

    Science.gov (United States)

    Dumont, Gérald; Pedrosa, Fernando Baltasar Dos Santos; Carbonez, Pierre; Forkel-Wirth, Doris; Ninin, Pierre; Fuentes, Eloy Reguero; Roesler, Stefan; Vollaire, Joachim

    2017-04-01

    CERN, the European Organization for Nuclear Research, upgraded its operational dosimetry system in March 2013 to be prepared for the first Long Shutdown of CERN's facilities. The new system allows the immediate and automatic checking and recording of the dosimetry data before and after interventions in radiation areas. To facilitate the analysis of the data in context of CERN's approach to As Low As Reasonably Achievable (ALARA), this new system is interfaced to the Intervention Management Planning and Coordination Tool (IMPACT). IMPACT is a web-based application widely used in all CERN's accelerators and their associated technical infrastructures for the planning, the coordination and the approval of interventions (work permit principle). The coupling of the operational dosimetry database with the IMPACT repository allows a direct and almost immediate comparison of the actual dose with the estimations, in addition to enabling the configuration of alarm levels in the dosemeter in function of the intervention to be performed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. EVIDOS: Individual dosimetry in mixed neutron and photon radiation fields

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2006-01-01

    The EVIDOS project (partly funded by the European Commission RTD Programme: Nuclear Energy, Euratom Framework Programme V, 1998-2002, Contract No FIKR-CT-2001-00175) aimed at improving individual monitoring in mixed neutron-photon radiation fields by evaluating the performance of routine and novel personal dosimeters for mixed radiation, and by giving guidelines for deriving sufficiently accurate values of personal dose equivalent from the readings of area survey instruments and dosimeters. The main objective of EVIDOS was to evaluate different methods for individual dosimetry in mixed neutron-photon work-places in nuclear industry. This implied a determination of the capabilities and limitations of personal dosimeters and the establishment of methods to enable sufficiently accurate values of personal dose equivalent from spectrometers, area survey instruments and routine personal dosimeters. Also novel electronic personal dosimeters were investigated. To this end spectrometric and dosimetric investigations in selected representative workplaces in nuclear industry where workers can receive significant neutron doses were performed. As part of this project, a number of tasks were executed, in particular: (1) the determination of the energy and direction distribution of the neutron fluence; (2) the derivation of the (conventionally true) values of radiation protection quantities; (3) the determination of the readings of routine and innovative personal dosimeters and of area monitors; and (4) the comparison between dosimeter readings and values of the radiation protection quantities

  10. Alanine dosimetry for clinical applications. Proceedings

    International Nuclear Information System (INIS)

    Anton, M.

    2006-05-01

    The following topics are dealt with: Therapy level alanine dosimetry at the UK Nationational Physical Laboratory, alanine as a precision validation tool for reference dosimetry, composition of alanine pellet dosimeters, the angular dependence of the alanine ESR spectrum, the CIAE alanine dosimeter for radiotherapy level, a correction for temporal evolution effects in alanine dosimetry, next-generation services foe e-traceability to ionization radiation national standards, establishing e-traceability to HIST high-dose measurement standards, alanine dosimetry of dose delivery from clinical accelerators, the e-scan alanine dosimeter reader, alanine dosimetry at ISS, verification of the integral delivered dose for IMRT treatment in the head and neck region with ESR/alanine dosimetry, alanine dosimetry in helical tomotherapy beams, ESR dosimetry research and development at the University of Palermo, lithium formate as a low-dose EPR radiation dosimeter, sensitivity enhancement of alanine/EPR dosimetry. (HSI)

  11. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  12. H-Area Seepage Basins groundwater monitoring report

    International Nuclear Information System (INIS)

    Thompson, C.Y.

    1992-06-01

    During first quarter 1992, tritium, nitrate, nonvolatile beta, total alpha-emitting radium (radium-224 and radium-226), gross alpha, antimony, mercury, lead, tetrachloroethylene, arsenic, and cadmium exceeded the US Environmental Protection Agency Primary Drinking Water Standards (PDWS) in groundwater samples from monitoring wells at the H-Area Seepage Basins (HASB) at the Savannah River Site. This report presents and discusses the groundwater monitoring results in the H-Area for first quarter 1992

  13. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  14. Basic requirements for personnel monitoring. 1980 ed

    International Nuclear Information System (INIS)

    1980-01-01

    This Code of Practice sets forth the objectives of an adequate system of personnel monitoring for radiation workers. It covers individual dosimetry, including internal radiation monitoring, and area monitoring to the extent required for the assessment of individual radiation doses. The responsibilities of authorities for organizing monitoring of radiation workers are discussed, together with brief descriptions of monitoring methods and the rules governing their application. The general principles to be considered in selecting instrumentation and the appropriate monitoring techniques are described, as well as calibration techniques, methods of data handling and record keeping. Current concepts and recommendations of the International Commission on Radiological Protection, as presented in ICRP Publication No.26, have been incorporated. New developments in techniques and instruments have been reflected, and several sections such as calibration and record keeping have been elaborated. The bibliography has been updated and new annexes added.

  15. Gaining competitive advantage in personal dosimetry services through ISO 9001 certification

    International Nuclear Information System (INIS)

    Noriah, M.A.

    2005-01-01

    Full text: In Malaysia, the harmonization of dose monitoring for almost 12,000 radiation workers is assigned to the Secondary Standard Dosimetry Laboratory of Malaysian Institute for Nuclear Technology Research, SSDL-MINT. Established in 1980, SSDL-MINT is responsible for improving personal and workplace safety by providing high quality personal dosimetry services. It is important to demonstrate that the performance of personal dosimetry meets recognized standards, to ensure radiation doses to individual workers are within the safe limits and to verify compliance with dose limits. Concern on the quality of personal dosimetry service began to be expressed in 2000. The concern led to the ISO certification, which brought an unprecedented effort characterized by high degree coordination, proper documentation and well trained of personal dosimetry operators. These huge efforts resulted with certification ISO 9002:1994 by the SIRIM International QAS Sdn. Bhd. in January 2002. The adoption of these requirements for the ISO 9002 standard makes routine handling of the process easier, and increases the reliability and effectiveness of the services. This helps to increase the quality and uniformity of personal dosimetry. The revision of the ISO 9002:1994 to ISO 9001:2000 necessitated SSDL-MINT revising its quality management system. The work began in middle 2002, and by May 2003, SSDL-MINT has been upgraded to ISO 9001:2000. Certification to the ISO 9001:2000 demonstrates our ability to consistency provide service that meets the requirements of the customer and the regulatory authority. These includes: improved consistency of service / product performance and therefore higher customer satisfaction levels; uniformity in work processes across organizations; simplified and more uniform structure for quality documents; improved customer perception of the organizations image, culture and performance; reduced number of product and process non-conformances; greater employee

  16. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  17. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  18. Automating the personnel dosimeter monitoring program

    International Nuclear Information System (INIS)

    Compston, M.W.

    1982-12-01

    The personnel dosimetry monitoring program at the Portsmouth uranium enrichment facility has been improved by using thermoluminescent dosimetry to monitor for ionizing radiation exposure, and by automating most of the operations and all of the associated information handling. A thermoluminescent dosimeter (TLD) card, worn by personnel inside security badges, stores the energy of ionizing radiation. The dosimeters are changed-out periodically and are loaded 150 cards at a time into an automated reader-processor. The resulting data is recorded and filed into a useful form by computer programming developed for this purpose

  19. Response of a neutron monitor area with TLDs pairs

    Energy Technology Data Exchange (ETDEWEB)

    Guzman G, K. A.; Borja H, C. G.; Valero L, C.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A., E-mail: ing_karen_guzman@yahoo.com.mx [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, Jose Gutierrez Abascal 2, E-28006 Madrid (Spain)

    2011-10-15

    The response of a passive neutron monitor area has been calculated using the Monte Carlo code MCNP5. The response was the amount of n({sup 6}Li, T){alpha} reactions occurring in a TLD-600 located at the center of a cylindrical polyethylene moderator. Fluence, (n, a) and H*(10) responses were calculated for 47 monoenergetic neutron sources. The H*(10) relative response was compared with responses of commercially available neutron monitors being alike. Due to {sup 6}Li cross section (n, {alpha}) reactions are mainly produced by thermal neutrons, however TLD-600 is sensitive to gamma-rays; to eliminate the signal due to photons monitor area was built to hold 2 pairs of TLD-600 and 2 pairs of TLD-700, thus from the difference between TLD-600 and TLD-700 readouts the net signal due to neutrons is obtained. The monitor area was calibrated at the Universidad Politecnica de Madrid using a {sup 241}AmBe neutron source; net TLD readout was compared with the H*(10) measured with a Bert hold Lb-6411. Performance of the neutron monitor area was determined through two independent experiments, in both cases the H*(10) was statistically equal to H*(10) measured with a Bert hold Lb-6411. Neutron monitor area with TLDs pairs can be used in working areas with intense, mixed and pulsed radiation fields. (Author)

  20. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  1. CAP vessel monitoring. Programme, measurement and neutron calculation

    International Nuclear Information System (INIS)

    Farrugia, J.M.; Nimal, J.C.; Totth, B.; Lloret, R.; Perdreau, R.

    1982-03-01

    Starting with the design of the CAP (Prototype Advanced NSSS), a programme for pressure vessel monitoring has been prepared, including dosimetry. The dosimetry programme encompasses activation dosimeters (Cu, Nb, Co) and fission dosimeters ( 237 Np, 238 U) installed either inside the pressure vessel with the monitoring test-samples, or in a counting tube outside the pressure vessel. In the first place, a description of the method for neutronic calculation is given; such calculations use the codes ANISN and MERCURE 4 allowing assessment of the neutron spectrum seen by the detectors and the related reaction coefficient. This is followed by a description of the instrumentation. The initial dosimetry results available after the initial operating cycles concur with calculations [fr

  2. Incorporation monitoring with triage measurements in Switzerland; Inkorporationsueberwachung mit Triagemessungen in der Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Elmiger, Raphael [Bundesamt fuer Gesundheit BAG, Liebefeld (Switzerland). Abteilung Strahlenschutz

    2017-08-01

    The actual valid concept of incorporation monitoring in Switzerland was implemented in 1999 with the regulation on personal dosimetry based on the recommendations of an expert group for dosimetry of the Helvetian commission for radiation protection (KSR). IN the sense of an uncomplicated and practical solution for the respective companies it is a two-step monitoring using two different measuring methods: a simplified triage measurement performed by the company and the incorporation measurement by an authorized dosimetry station.

  3. Application of numerical analysis methods to thermoluminescence dosimetry; Aplicacion de metodos de analisis numerico a la dosimetria por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J M; Delgado, A

    1989-07-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs.

  4. Impact of the internal contamination monitoring for national and international regulations

    International Nuclear Information System (INIS)

    Gaburo, J.C.; Sordi, G.M.

    1996-01-01

    An evaluation of the internal radiation dose received by workers between 1984 and 1994 was performed, after a brief description of IPEN facility. The National and International Recommendation aims to reduce the workers' doses below 1/10 of the annual limits. The routine monitoring should be eliminated, if the individual annual dose is below 3/10 of the annual limits. In this case, only the operational monitoring should be maintained. In principle, the concept of restricted area should be reviewed, because, according to Publication 26 of ICRP, 1977, it should be a supervised area instead. The new concept of restricted area recommended by the Publication 60, ICRP 1991, should be adjusted accordingly. Thus, the classification used by the Commission-controlled areas and supervised areas will be with the foreseeable dose and not with the actual dose. When the individual annual dose is kept below 1/10 of the annual limits, the routine monitoring is not necessary, and only operational monitoring is needed. Finally, the future possible activities of the Individual Internal Dosimetry Laboratory at IPEN are discussed, after the elimination of individual monitoring. (authors). 8 refs

  5. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  6. Optically stimulated luminescence in electronic components for emergency dosimetry

    International Nuclear Information System (INIS)

    Geber-Bergstrand, T.; Bernhardsson, C.; Mattsson, S.; Raeaef, C.L.

    2015-01-01

    Document available in abstract form only. Full text of publication follows: Accidents and, luckily more rarely, attacks involving nuclear or radiological material do occur from time to time. A very possible consequence of an accident or attack of this kind is that nearby people might be exposed to ionising radiation. Since these types of exposure situations, unlike the ones occurring in medicine, are unplanned, there are no radiation-monitoring data available. For several reasons, it is nevertheless of value to find out the dose that these people have received. The first and most urgent reason is after-the-event triage, to be able to carry out proper medical treatments and also to focus the available medical assets to the persons needing it the most. This is where different retrospective dosimetry techniques, such as luminescence, can be employed. Various electronic components from mobile phones and other portable devices have been studied using optically stimulated luminescence for their potential use in retrospective dosimetry. Previous investigations have been performed in laboratory conditions and have showed very promising properties for emergency dosimetry. In this study, the more practical parts of using electronic components in retrospective dosimetry have been considered. In a triage situation, one of the key parameters to consider is time; thus, effort has been made to speed up the readout procedure, yet without the loss of too much accuracy. (authors)

  7. Fourth international radiopharmaceutical dosimetry symposium

    International Nuclear Information System (INIS)

    Schlafke-Stelson, A.T.; Watson, E.E.

    1986-04-01

    The focus of the Fourth International Radiopharmaceutical Dosimetry Symposium was to explore the impact of current developments in nuclear medicine on absorbed dose calculations. This book contains the proceedings of the meeting including the edited discussion that followed the presentations. Topics that were addressed included the dosimetry associated with radiolabeled monoclonal antibodies and blood elements, ultrashort-lived radionuclides, and positron emitters. Some specific areas of discussion were variations in absorbed dose as a result of alterations in the kinetics, the influence of radioactive contaminants on dose, dose in children and in the fetus, available instrumentation and techniques for collecting the kinetic data needed for dose calculation, dosimetry requirements for the review and approval of new radiopharmaceuticals, and a comparison of the effect on the thyroid of internal versus external irradiation. New models for the urinary blader, skeleton including the active marrow, and the blood were presented. Several papers dealt with the validity of traditional ''average-organ'' dose estimates to express the dose from particulate radiation that has a short range in tissue. These problems are particularly important in the use of monoclonal antibodies and agents used to measure intracellular functions. These proceedings have been published to provide a resource volume for anyone interested in the calculation of absorbed radiation dose

  8. Thermoluminescence dosimetry of gamma rays from the fallout of the Semipalatinsk nuclear tests

    International Nuclear Information System (INIS)

    Takada, J.; Hoshi, M.; Endo, S.; Yamamoto, M.; Nagatomo, T.; Gusev, B.I.; Rozenson, R.I.; Apsalikov, K.N.; Tchaijunusova, N.J.

    1996-01-01

    Field missions were sent to several settlements near the Semipalatinsk nuclear test site out in order to investigate dosimetry for the residents in 1995. The results of measurements of environmental radiation doses and thermoluminescence dosimetry in some villages near the Semipalatinsk nuclear test site are presented. The radiation levels in several villages are the natural background level in 1995, 6 years after the final nuclear explosion. On the other hand, thermoluminescence dosimetry revealed significant radiation exposure to residents in this area due to nuclear tests. (author)

  9. Atomics International environmental monitoring and facility effluent annual report, 1976

    International Nuclear Information System (INIS)

    Moore, J.D.

    1977-01-01

    Environmental and facility effluent radioactivity monitoring at Atomics International (AI) is performend by the Radiation and Nuclear Safety Unit of the Health, Safety, and Radiation Services Department. Soil, vegetation, and surface water are routinely sampled to a distance of 10 miles from AI sites. Continuous ambient air sampling and thermoluminescent dosimetry are performed on site for monitoring airborne radioactivity and site ambient radiation levels. Radioactivity in effluents discharged to the atmosphere from AI facilities is continuously sampled and monitored to ensure that levels released to unrestricted areas are within appropriate limits, and to identify processes which may require additional engineering safeguards to minimize radioactivity levels in such effluents. In addition, selected nonradioactive constituents in surface water discharged to unrestricted areas are determined. This report summarizes and discusses monitoring results for 1976. The results of a special soil plutonium survey performed during the year are also summarized

  10. In vivo thermoluminescent dosimetry in studies of helicoid computed tomography and excretory urogram

    International Nuclear Information System (INIS)

    Cruz C, D.; Azorin N, J.; Saucedo A, V.M.; Barajas O, J.L.

    2005-01-01

    The dosimetry is the field of measurement of the ionizing radiations. It final objective is to determine the 'absorbed dose' for people. The dosimetry is vital in the radiotherapy, the radiological protection and the treatment technologies by irradiation. Presently work, we develop 'In vivo' dosimetry, in exposed patients to studies of helical computed tomography and excretory urogram. The dosimetry 'in vivo' was carried out in 20 patients selected aleatorily, for each medical study. The absorbed dose was measured in points of interest located in crystalline, thyroid, chest and abdomen of each patient, by means of thermoluminescent dosemeters (TLD) LiF: Mg,Cu,P + Ptfe of national fabrication. Also it was quantified the dose in the working area. (Author)

  11. Monitoring and radiation dose estimation for internal contamination of occupational workers

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    The assessment of interval radiation doses due to intake of radionuclides differs totally from external dosimetry. External dosimetry is relatively straight forward: Workers are equipped with appropriate dosimeters that give the dose upon direct reading. Internal dosimetry is actually an assessment of the dose based on results of personnel and environmental monitoring (authors).

  12. Internal dosimetry and control

    International Nuclear Information System (INIS)

    Rich, B.L.

    1990-05-01

    This internal dosimetry and control report provides guidance for EG ampersand G Idaho, Inc., field programs in detecting, evaluating, and controlling personnel exposure resulting from uptake of radionuclides by the body. Procedures specific to each program or facility are required to define the details of guidance from this report. Fundamental principles related to philosophy, policies, monitoring guidelines, and dose evaluation are discussed. Specific numerical guides and action levels are developed to guide the programs in evaluating the significance of specific analytical results. The requirement to thoroughly document the results and provide a formal technical base for each policy and/or practice is outlined and explained. 8 refs., 3 figs., 7 tabs

  13. New web interface for Personal dosimetry VF, a.s

    International Nuclear Information System (INIS)

    Studeny, J.

    2014-01-01

    The lecture will introduce new functions and graphic design WebSOD - web interface Personal dosimetry Service VF. a.s. which will be updated in November 2014. The new interface will have a new graphic design, intuitive control system and will be providing a range of new functions: - Personal doses - display of personal doses from personal, extremity and neutron dosimeters including graphs, annual and electronic listings of doses; - Collective doses - display of group doses for selected periods of time; Reference levels - setting and display of three reference levels; - Evidence - enables administration of monitored individuals - beginning, ending of monitoring, or editing the data of monitored persons and centers. (author)

  14. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  15. Research needs related to internal dosimetry. Joint panel on occupational and environmental research for uranium production in Canada (JP-1)

    Energy Technology Data Exchange (ETDEWEB)

    Duport, P; Pomroy, C [Atomic Energy Control Board, Ottawa, ON (Canada); Brown, D [Saskatchewan Human Resources, Labour and Employment, Regina (Canada)

    1990-12-31

    There are several important techniques of internal dosimetry for use with uranium mine and mill workers: personal radon daughter dosimetry, uranium content of urine, whole body counter to evaluate the uranium in lung burden, and assay of uranium in biopsy or autopsy tissue samples. There are problems with each of these techniques and further research is required in internal dosimetry (as well as the alternative of monitoring exposure levels). This research should be aimed at improved or supplementary dosimetry techniques, enhanced theoretical interpretation of dosimetry results and fundamental research not directly related to the techniques mentioned above. Proposals for research as presented by the working group in this report should be considered by funding organizations concerned with internal dosimetry as it relates to the uranium mining industry, and, since this report was first presented. AECB has proceeded with related projects. (author).

  16. Research needs related to internal dosimetry. Joint panel on occupational and environmental research for uranium production in Canada (JP-1)

    International Nuclear Information System (INIS)

    Duport, P.; Pomroy, C.; Brown, D.

    1989-01-01

    There are several important techniques of internal dosimetry for use with uranium mine and mill workers: personal radon daughter dosimetry, uranium content of urine, whole body counter to evaluate the uranium in lung burden, and assay of uranium in biopsy or autopsy tissue samples. There are problems with each of these techniques and further research is required in internal dosimetry (as well as the alternative of monitoring exposure levels). This research should be aimed at improved or supplementary dosimetry techniques, enhanced theoretical interpretation of dosimetry results and fundamental research not directly related to the techniques mentioned above. Proposals for research as presented by the working group in this report should be considered by funding organizations concerned with internal dosimetry as it relates to the uranium mining industry, and, since this report was first presented. AECB has proceeded with related projects. (author)

  17. Adequacy of individual monitoring of external exposure at the workplace

    International Nuclear Information System (INIS)

    Rannou, A.

    2006-01-01

    Individual monitoring of workers exposed to external radiations must fulfill technical, regulatory and organizational requirements. The external dosimetry should be adapted to the workplace. The relevant dosimetric techniques have to be chosen upon the workplace study that conditions both the categorization of exposed workers and classification of areas. Solutions exist which are satisfactory for the most situations. However, rational solutions still have to be found for a few specific situations. (author)

  18. Is intraoperative real-time dosimetry in prostate seed brachytherapy predictive of biochemical outcome?

    Directory of Open Access Journals (Sweden)

    Daniel Taussky

    2017-06-01

    Full Text Available Purpose : To analyze intraoperative (IO dosimetry using transrectal ultrasound (TRUS, performed before and after prostate low-dose-rate brachytherapy (LDR-BT, and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30. Material and methods : A total of 236 patients underwent prostate LDR-BT using 125 I that was performed with a three-dimensional TRUS-guided interactive inverse preplanning system (preimplant dosimetry. After the implant procedure, the TRUS was repeated in the operating room, and the dosimetry was recalculated (postimplant dosimetry and compared to dosimetry on Day 30 computed tomography (CT scans. Area under curve (AUC statistics was used for models predictive of dosimetric parameters at Day 30. Results : The median follow-up for patients without BF was 96 months, the 5-year and 8-year biochemical recurrence (BR-free rate was 96% and 90%, respectively. The postimplant median D 90 was 3.8 Gy lower (interquartile range [IQR], 12.4-0.9, and the V 100 only 1% less (IQR, 2.9-0.2% than the preimplant dosimetry. When comparing the postimplant and the Day 30 dosimetries, the postimplant median D 90 was 9.6 Gy higher (IQR [–] 9.5-30.3 Gy, and the V 100 was 3.2% greater (0.2-8.9% than Day 30 postimplant dosimetry. The variables that best predicted the D 90 of Day 30 was the postimplant D 90 (AUC = 0.62, p = 0.038. None of the analyzed values for IO or Day 30 dosimetry showed any predictive value for BR. Conclusions : Although improving the IO preimplant and postimplant dosimetry improved dosimetry on Day 30, the BR-free rate was not dependent on any dosimetric parameter. Unpredictable factors such as intraprostatic seed migration and IO factors, prevented the accurate prediction of Day 30 dosimetry.

  19. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  20. Proceedings of the V. international symposium 'Actual problems of dosimetry'; Materialy V mezhdunarodnogo simpoziuma 'Aktual'nye problemy dozimetrii'

    Energy Technology Data Exchange (ETDEWEB)

    Kundas, S P; Okeanov, A E [International A. Sakharov environmental univ., Minsk (Belarus); Shevchuk, V E [Komitet po problemam posledstvij katastrofy na Chernobyl' skoj AEhS pri Sovete Ministrov Respubliki Belarus' , Minsk (Belarus)

    2005-10-01

    The main topics of the workshop were: monitoring and reconstruction of radiation doses at radiation accidents, biological dosimetry and markers of radiation effects as well as normative, metrological and technical aspects of dosimetric and radiometric monitoring.

  1. Nevada Test 1999 Waste Management Monitoring Report, Area 3 and Area 5 radioactive waste management sites

    International Nuclear Information System (INIS)

    Yvonne Townsend

    2000-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS). These monitoring data include radiation exposure, air, groundwater, meteorology, vadose zone, and biota data. Although some of these media (radiation exposure, air, and groundwater) are reported in detail in other Bechtel Nevada reports (Annual Site Environmental Report [ASER], the National Emissions Standard for Hazardous Air Pollutants [NESHAP] report, and the Annual Groundwater Monitoring Report), they are also summarized in this report to provide an overall evaluation of RWMS performance and environmental compliance. Direct radiation monitoring data indicate that exposure at and around the RWMSs is not above background levels. Air monitoring data indicate that tritium concentrations are slightly above background levels, whereas radon concentrations are not above background levels. Groundwater monitoring data indicate that the groundwater in the alluvial aquifer beneath the Area 5 RWMS has not been affected by the facility. Meteorology data indicate that 1999 was a dry year: rainfall totaled 3.9 inches at the Area 3 RWMS (61 percent of average) and 3.8 inches at the Area 5 RWMS (75 percent of average). Vadose zone monitoring data indicate that 1999 rainfall infiltrated less than one foot before being returned to the atmosphere by evaporation. Soil-gas tritium data indicate very slow migration, and tritium concentrations in biota were insignificant. All 1999 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing as expected at isolating buried waste

  2. Moisture Monitoring at Area G, Technical Area 54, Los Alamos National Laboratory, 2016 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Levitt, Daniel Glenn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jennings, Terry L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-17

    Hydrological characterization and moisture monitoring activities provide data required for evaluating the transport of subsurface contaminants in the unsaturated and saturated zones beneath Area G, and for the Area G Performance Assessment and Composite Analysis. These activities have been ongoing at Area G, Technical Area 54 of the Los Alamos National Laboratory since waste disposal operations began in 1957. This report summarizes the hydrological characterization and moisture monitoring activities conducted at Area G. It includes moisture monitoring data collected from 1986 through 2016 from numerous boreholes and access tubes with neutron moisture meters, as well as data collected by automated dataloggers for water content measurement sensors installed in a waste disposal pit cover, and buried beneath the floor of a waste disposal pit. This report is an update of a nearly identical report by Levitt et al., (2015) that summarized data collected through early 2015; this report includes additional moisture monitoring data collected at Pit 31 and the Pit 38 extension through December, 2016. It also includes information from the Jennings and French (2009) moisture monitoring report and includes all data from Jennings and French (2009) and the Draft 2010 Addendum moisture monitoring report (Jennings and French, 2010). For the 2015 version of this report, all neutron logging data, including neutron probe calibrations, were investigated for quality and pedigree. Some data were recalculated using more defensible calibration data. Therefore, some water content profiles are different from those in the Jennings and French (2009) report. All of that information is repeated in this report for completeness. Monitoring and characterization data generally indicate that some areas of the Area G vadose zone are consistent with undisturbed conditions, with water contents of less than five percent by volume in the top two layers of the Bandelier tuff at Area G. These data also

  3. Thin film tritium dosimetry

    Science.gov (United States)

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  4. Thermocurrent dosimetry with high purity aluminum oxide

    Energy Technology Data Exchange (ETDEWEB)

    Fullerton, G.D.; Cameron, J.R.; Moran, P.R.

    1976-01-01

    The application of thermocurrent (TC) to ionizing radiation dosimetry was studied. It was shown that TC in alumina (Al/sub 2/O/sub 3/) has properties that are suited to personnel dosimetry and environmental monitoring. TC dosimeters were made from thin disks of alumina. Aluminum electrodes were evaporated on each side: on one face a high voltage electrode and on the opposite face a measuring electrode encircled by a guard ring. Exposure to ionizing radiation resulted in stored electrons and holes in metastable trapping sites. The signal was read-out by heating the dosimeter with a voltage source and picnometer connected in series between the opposite electrodes. The thermally remobilized charge caused a transient TC. The thermogram, TC versus time or temperature, is similar to a TL glow curve. Either the peak current or the integrated current is a measure of absorbed dose. Six grades of alumina were studied from a total of four commercial suppliers. All six materials displayed radiation induced TC signals. Sapphire of uv-grade quality from the Adolf Meller Co. (AM) had the best dosimetry properties of those investigated. Sources of interference were studied. Thermal fading, residual signal and radiation damage do not limit TC dosimetry. Ultraviolet light can induce a TC response but it is readily excluded with uv-opaque cladding. Improper surface preparation prior to electrode evaporation was shown to cause interference. A spurious TC signal resulted from polarization of surface contaminants. Spurious TC was reduced by improved cleaning prior to electrode application. Polished surfaces resulted in blocking electrodes and caused a sensitivity shift due to radiation induced thermally activated polarization. This was not observed with rough cut surfaces.

  5. Thermocurrent dosimetry with high purity aluminum oxide

    International Nuclear Information System (INIS)

    Fullerton, G.D.; Cameron, J.R.; Moran, P.R.

    1976-01-01

    The application of thermocurrent (TC) to ionizing radiation dosimetry was studied. It was shown that TC in alumina (Al 2 O 3 ) has properties that are suited to personnel dosimetry and environmental monitoring. TC dosimeters were made from thin disks of alumina. Aluminum electrodes were evaporated on each side: on one face a high voltage electrode and on the opposite face a measuring electrode encircled by a guard ring. Exposure to ionizing radiation resulted in stored electrons and holes in metastable trapping sites. The signal was read-out by heating the dosimeter with a voltage source and picnometer connected in series between the opposite electrodes. The thermally remobilized charge caused a transient TC. The thermogram, TC versus time or temperature, is similar to a TL glow curve. Either the peak current or the integrated current is a measure of absorbed dose. Six grades of alumina were studied from a total of four commercial suppliers. All six materials displayed radiation induced TC signals. Sapphire of uv-grade quality from the Adolf Meller Co. (AM) had the best dosimetry properties of those investigated. Sources of interference were studied. Thermal fading, residual signal and radiation damage do not limit TC dosimetry. Ultraviolet light can induce a TC response but it is readily excluded with uv-opaque cladding. Improper surface preparation prior to electrode evaporation was shown to cause interference. A spurious TC signal resulted from polarization of surface contaminants. Spurious TC was reduced by improved cleaning prior to electrode application. Polished surfaces resulted in blocking electrodes and caused a sensitivity shift due to radiation induced thermally activated polarization. This was not observed with rough cut surfaces

  6. Fast neutron dosimetry

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Pearson, D.W.

    1992-01-01

    This progress report concentrates on two major areas of dosimetry research: measurement of fast neutron kerma factors for several elements for monochromatic and white spectrum neutron fields and determination of the response of thermoluminescent phosphors to various ultra-soft X-ray energies and beta-rays. Dr. Zhixin Zhou from the Shanghai Institute of Radiation Medicine, People's Republic of China brought with him special expertise in the fabrication and use of ultra-thin TLD materials. Such materials are not available in the USA. The rather unique properties of these materials were investigated during this grant period

  7. 2016 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    Energy Technology Data Exchange (ETDEWEB)

    Black, David [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-08-30

    Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) within the Nevada National Security Site (NNSS). These data include direct radiation exposure, as well as radiation from the air, groundwater, meteorology, and vadose zone. This report summarizes the 2016 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports, developed by National Security Technologies, LLC Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data show that tritium concentrations in water vapor and americium and plutonium concentrations in air particles are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS were all below established investigation levels. Leachate samples collected from the leachate collection system at the mixed low-level waste cell were below established contaminant regulatory limits. During 2016, precipitation at the Area 3 RWMS was 8% below average, and precipitation at the Area 5 RWMS was 8% above average. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation as measured from the bare-soil weighing lysimeter. Vadose zone monitoring on Area 5 and Area 3 RWMS cell covers shows no evidence of precipitation percolating through the covers

  8. IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Bera, P.; Vatnitsky, S.

    2002-01-01

    Since 1969 the International Atomic Energy Agency, together with the World Health Organization, has performed postal TLD audits to verify calibration of radiotherapy beams in developing countries. The TLD programme also monitors activities of Secondary Standard Dosimetry Laboratories (SSDLs). The programme has checked approximately 4000 clinical beams in over 1100 hospitals, and in many instances significant errors have been detected in the beam calibration. Subsequent follow-up actions help to resolve the discrepancies, thus preventing further mistreatment of patients. The audits for SSDLs check the implementation of the dosimetry protocol in order to assure proper dissemination of dosimetry standards to the end-users. The TLD audit results for SSDLs show good consistency in the basic dosimetry worldwide. New TLD procedures and equipment have recently been introduced by the IAEA that include a modified TLD calibration methodology and computerised tools for automation of dose calculation from TLD readings. (author)

  9. Nevada Test Site 2001 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    Y. E. Townsend

    2002-06-01

    Environmental monitoring data, subsidence monitoring data, and meteorology monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) (refer to Figure 1). These monitoring data include radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota data. Although some of these media (radiation exposure, air, and groundwater) are reported in detail in other Bechtel Nevada (BN) reports (Annual Site Environmental Report [ASER], the National Emissions Standard for Hazardous Air Pollutants [NESHAP] report, and the Annual Groundwater Monitoring Report), they are also summarized in this report to provide an overall evaluation of RWMS performance and environmental compliance. Direct radiation monitoring data indicate that exposure at and around the RWMSs is not above background levels. Air monitoring data indicate that tritium concentrations are slightly above background levels. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS has not been affected by the facility. Meteorology data indicate that 2001 was an average rainfall year: rainfall totaled 150 mm (5.9 in) at the Area 3 RWMS and 120 mm (4.7 in) at the Area 5 RWMS. Vadose zone monitoring data indicate that 2001 rainfall infiltrated less than one meter (3 ft) before being returned to the atmosphere by evaporation. Soil-gas tritium monitoring data indicate slow subsurface migration, and tritium concentrations in biota were lower than in previous years. All 2001 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility performance assessments

  10. New advanced TLD system for space dosimetry

    International Nuclear Information System (INIS)

    Feher, I.; Szabo, B.; Vagvoelgyi, J.; Deme, S.; Szabo, P.P.; Csoeke, A.

    1983-10-01

    A new version of the TLD reader type PILLE has been developed for space applications. The earlier compact and portable device could also be used for measurements during space flights but its range was limited. A new bulb detector with easier handling has also been developed with an upper limit of linear dose response of 10 Gy. The range of this new and more versatile reader, NA206S, (1μGy-10 Gy) is 3 orders of magnitude higher than that of the earlier system; it also has increased sensitivity and decreased mass. It can be used not only in space applications but also for environmental monitoring or even in accident dosimetry. The measured dose value is displayed on a four-digit display with automatic range switch. Another new version, the NA206E, has been developed for environmental dosimetry; it can be operated from a battery or from the mains. (author)

  11. Groundwater Monitoring Plan for the Z-Area Saltstone Facility

    International Nuclear Information System (INIS)

    Wells, D.

    2002-01-01

    Groundwater monitoring has been conducted at the Z-Area Saltstone Disposal Facility since 1987. At that time, groundwater monitoring was not required by the industrial landfill regulations, but a modest monitoring program was required by the operating permit. In 1996 SRS proposed a program based on direct push sampling. This program called for biennial direct push sampling within 25 feet of each waste-containing cell with additional samples being taken in areas where excessive cracking had been observed. The direct push proposal was accepted by The South Carolina Department of Health and Environmental Control (SCDHEC). The Industrial Solid Waste Landfill Regulations were revised in 1998 and now include requirements for groundwater monitoring. The major elements of those regulations and their application at Z-Area are discussed. These are a point of compliance, groundwater protection standards, the groundwater monitoring system, sampling and analysis, and data evaluation and reporting

  12. Advances in reference and transfer dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Desrosiers, M.F. [Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    1999-07-01

    All prerequisites are now in place to create a fundamentally and radically different type of calibration service for the radiation processing industry. Advancements in dosimetry and information technology can be combined to provide industry with on-line calibrations, on demand at a low cost. The remote calibration service will serve as a basis for other areas of metrology. (Author)

  13. Advances in reference and transfer dosimetry

    International Nuclear Information System (INIS)

    Desrosiers, M.F.

    1999-01-01

    All prerequisites are now in place to create a fundamentally and radically different type of calibration service for the radiation processing industry. Advancements in dosimetry and information technology can be combined to provide industry with on-line calibrations, on demand at a low cost. The remote calibration service will serve as a basis for other areas of metrology. (Author)

  14. Survey monitoring of environmental radioactivity in Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jae Shik.; Noh, Hyung Ah [Taejon Radiation Monitoring Station, Daejeon (Korea, Republic of)

    2000-12-15

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Taejon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Taejon Radiation Monitoring Station in 2000. In conclusion, the natural environmental radiation level in Taejon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period.

  15. Survey monitoring of environmental radioactivity in Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jae Sik; Noh, Hyung Ah [Daejon Radiation Monitoring Station, Daejeon (Korea, Republic of)

    2001-12-15

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Daejeon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Daejeon Radiation Monitoring Station in 2001. In conclusion, the natural environmental radiation level in Daejeon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period.

  16. Survey monitoring of environmental radioactivity in Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jae Shik; Noh, Hyung Ah [Daejon Radiation Monitoring Station, Daejeon (Korea, Republic of)

    2002-12-15

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Daejeon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Daejeon Radiation Monitoring Station in 2002. In conclusion, the natural environmental radiation level in Daejeon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period.

  17. Survey monitoring of environmental radioactivity in Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jae Shik; Noh, Hyung Ah [Daejon Radiation Monitoring Station, Daejeon (Korea, Republic of)

    2003-12-15

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Daejeon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Daejeon Radiation Monitoring Station in 2002. In conclusion, the natural environmental radiation level in Daejeon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period.

  18. Survey monitoring of environmental radioactivity in Daejeon area

    International Nuclear Information System (INIS)

    Jun, J. S.; Kim, K. S.

    1998-01-01

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Taejon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Taejon Radiation Monitoring Station in 1998. In conclusion, the natural environmental radiation level in Taejon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period

  19. Survey monitoring of environmental radioactivity in Daejeon area

    International Nuclear Information System (INIS)

    Jun, Jae Sik; Noh, Hyung Ah

    2001-12-01

    Systematic understanding of the distribution of environmental radioactivity and radiation level in Daejeon, including Chungchung area, in normal circumstance, and rapid detection of unusual variation of the radiation level in emergency situation thereby ensure public safety are the objectives of this project to be carried out. This report summarizes and interprets environmental radiation/radioactivity monitoring data obtained at Daejeon Radiation Monitoring Station in 2001. In conclusion, the natural environmental radiation level in Daejeon area has been preserved as usual and no significant artificial enhancement in environmental radioactivity was observed during the course of this survey and monitoring period

  20. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  1. Fundamentals of x-ray dosimetry

    International Nuclear Information System (INIS)

    Roesch, W.C.

    1976-01-01

    Fundamental information about x-ray dosimetry is presented. Definitions are given and expanded on for dose, absorbed dose including microdosimetry, radiation physics (properties of the radiation that are important to dosimetry), and dosimetry (how the properties are dealt with in determining dose). 5 figs, 12 refs

  2. Development of dosimetry tools for proton therapy research

    International Nuclear Information System (INIS)

    Kim, Jong-Won; Kim, Dogyun

    2010-01-01

    Dosimetry tools for proton therapy research have been developed to measure the properties of a therapeutic proton beam. A CCD camera-scintillation screen system, which can verify the 2D dose distribution of a scanning beam and can be used for proton radiography, was developed. Also developed were a large area parallel-plate ionization chamber and a multi-layer Faraday cup to monitor the beam current and to measure the beam energy, respectively. To investigate the feasibility of locating the distal dose falloff in real time during patient treatment, a prompt gamma measuring system composed of multi-layer shielding structures was then devised. The system worked well for a pristine proton beam. However, correlation between the distal dose falloff and the prompt gamma distribution was blurred by neutron background for a therapy beam formed by scattering method. We have also worked on the design of a Compton camera to image the 2D distribution of prompt gamma rays.

  3. Radiation monitoring policy at the advanced light source

    International Nuclear Information System (INIS)

    Donahue, R.; Heinzelman, K.; Perdue, G.

    1998-01-01

    When the accelerator first began operation it was decided that, until we had the necessary dosimetry data to decide otherwise, we would badge the entire worker and experimental population. Each person was issued a dosimetry badge that contained 4 TLD elements. Badges were processed on a monthly basis. After three years of analyzing a total of 65,000 TLD elements, the decision was made to modify the radiation monitoring policy at the ALS. Only those individuals in the workforce that have any potential for exposure, no matter how small, would be badged. Subsequently, DOE conducted an independent review of the ALS radiation monitoring and dosimetry program. This review concluded that the ALS program, if expanded as proposed, would be adequate under the 10 CFR 835 Rule to establish radiation exposures to an acceptable level of confidence. The review team recommended the ALS provide more comprehensive documentation on the basis for its radiation protection and monitoring program. This document describes the technical justification for that program

  4. Nevada Test Site 2000 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    Yvonne Townsend

    2001-01-01

    Environmental monitoring data, subsidence monitoring data, and meteorology monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) (refer to Figure 1). These monitoring data include radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota data. Although some of these media (radiation exposure, air, and groundwater) are reported in detail in other Bechtel Nevada reports (Annual Site Environmental Report [ASER], the National Emissions Standard for Hazardous Air Pollutants [NESHAP] report, and the Annual Groundwater Monitoring Report), they are also summarized in this report to provide an overall evaluation of RWMS performance and environmental compliance. Direct radiation monitoring data indicate that exposure at and around the RWMSs is not above background levels. Air monitoring data indicate that tritium concentrations are slightly above background levels, whereas radon concentrations are not above background levels. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS has not been affected by the facility. Meteorology data indicate that 2000 was an average rainfall year: rainfall totaled 167 mm (6.6 in) at the Area 3 RWMS (annual average is 156 mm [6.5 in]) and 123 mm (4.8 in) at the Area 5 RWMS (annual average is 127 mm [5.0 in]). Vadose zone monitoring data indicate that 2000 rainfall infiltrated less than one meter (3 ft) before being returned to the atmosphere by evaporation. Soil-gas tritium monitoring data indicate slow subsurface migration, and tritium concentrations in biota were lower than in previous years. All 2000 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing well at isolating buried waste

  5. Experiments in the Underground Laboratory for Dosimetry and Spectrometry (UDO) of the PTB in the Asse II salt mine - summary highlighting work performed and outlook

    CERN Document Server

    Neumaier, S; Zwiener, R

    2003-01-01

    Due to its extremely low area dose rate, the Underground Laboratory for Dosimetry and Spectrometry (UDO) of the PTB at the 925 m level of the Asse II Salt Mine offers unique possibilities for the investigation and calibration of dosimetry systems of high sensitivity as are used, for example, in environmental monitoring. Due to its low area dose rate, this laboratory has an outstanding position worldwide. The low ambient dose equivalent rate in the UDO of approx. 1 nSv/h, that means of only approx. 1 percent of the ambient dose rate typically encountered at the Earth's surface, is mainly due to the following reasons: - At the depth at which the UDO is situated, the penetrating muon component of cosmic radiation which considerably contributes to the environmental equivalent dose rate at the Earth's surface (in Braunschweig, for example, approx. one third) is already attenuated by more than five orders of magnitude and is therefore completely negligible for dosimetric investigations; - The activity concentration...

  6. Wide area monitoring study

    International Nuclear Information System (INIS)

    Wogman, N.A.; Holdren, G.R. Jr.

    1999-01-01

    Environmental sampling can be used to complement the safeguarding of nuclear material, especially in the detection of undeclared nuclear activities. Routine monitoring of nuclear installations has provided valuable information about the fate of key signature materials within different environmental settings. The approach collates information regarding the generation of individual radiochemical signatures within different nuclear processes, the potential for release of these signatures to the environment and, the chemical form and mobility of the signatures in environmental media along which the material could migrate. Meteorological, geological and hydrological information is used to determine where to sample, what to sample, and how often to sample to provide the greatest likelihood for detection. Multiple strategies can be used to implement wide area monitoring for safeguards purposes. The most complex, and expensive of these, involves establishing extensive networks of fixed location sampling sites. The sites would be operated continuously, and would be instrumented with automated sampling, analysis, and communication equipment to relay information regarding potential anomalies to control centers in near-real time. Alternative strategies can be used to supplement fixed location monitoring equipment, especially in regions that cannot support (financially or logistically) the fixed stations. Through combinations of these various strategies, using a variety of environmental media to monitor a region, we believe that a competent network, one with a quantifiable probability for detecting undeclared nuclear activities, can be designed. While this approach cannot and should not replace other inspection and monitoring activities, it can potentially contribute valuable information to an international safeguards system. (author)

  7. CIEMAT EXTERNAL DOSIMETRY SERVICE: ISO/IEC 17025 ACCREDITATION AND 3 Y OF OPERATIONAL EXPERIENCE AS AN ACCREDITED LABORATORY.

    Science.gov (United States)

    Romero, A M; Rodríguez, R; López, J L; Martín, R; Benavente, J F

    2016-09-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. The use of sugar pellets in ESR [electron spin resonance] dosimetry

    International Nuclear Information System (INIS)

    Tchen, A.; Greenstock, C.L.; Trivedi, A.

    1993-01-01

    Table sugar (sucrose) is a convenient, common, tissue-equivalent material suitable for electron spin resonance (ESR) dosimetry of ionising radiation. The simple free radical signal in irradiated sugar is stabilised if the sugar is made into pellets using an inert silicone elastomer (Dow Corning 732). Such pellets, which offer greater convenience and signal stability and reproducibility, have been prepared and tested for their radiation response, sensitivity and post-irradiation stability. Irradiated sugar is detectable at ≥0.1 Gy, the signal intensity is linear with dose, and the fading of the signal, post-irradiation, is minimal for samples kept under ambient conditions. These pellets themselves, given sufficient post-irradiation signal stability, may be useful for environmental monitoring to determine long-term exposures in remote areas or at strategic locations. (Author)

  9. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  10. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  11. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  12. Performance testing of dosimetry processors, status of NRC rulemaking for improved personnel dosimetry processing, and some beta dosimetry and instrumentation problems observed by NRC regional inspectors

    International Nuclear Information System (INIS)

    Dennis, N.A.; Kinneman, J.D.; Costello, F.M.; White, J.R.; Nimitz, R.L.

    1983-01-01

    Early dosimetry processor performance studies conducted between 1967 and 1979 by several different investigators indicated that a significant percentage of personnel dosimetry processors may not be performing with a reasonable degree of accuracy. Results of voluntary performance testing of US personnel dosimetry processors against the final Health Physics Society Standard, Criteria for Testing Personnel Dosimetry Performance by the University of Michigan for the Nuclear Regulatory Commission (NRC) will be summarized with emphasis on processor performance in radiation categories involving beta particles and beta particles and photon mixtures. The current status of the NRC's regulatory program for improved personnel dosimetry processing will be reviewed. The NRC is proposing amendments to its regulations, 10 CFR Part 20, that would require its licensees to utilize specified personnel dosimetry services from processors accredited by the National Voluntary Laboratory Accreditation Program of the National Bureau of Standards. Details of the development and schedule for implementation of the program will be highlighted. Finally, selected beta dosimetry and beta instrumentation problems observed by NRC Regional Staff during inspections of NRC licensed facilities will be discussed

  13. Personal dosimetry at the radiation accidents

    International Nuclear Information System (INIS)

    Perevoznikov, O.N.; Klyuchnikov, A.A.; Kanchenko, V.A.

    2007-01-01

    The radiation accidents of different types and the methods of the dosimetry used at the consequences liquidation are considered. The long-term experience of the population personal instrumental dosimetric control carrying out at the ChNPP accident consequences liquidation is widely covered in details. The concepts are stated out and the results are presented on the functioning of the created system for personal dose monitoring of the population of Ukraine irradiation. The use of the person radiation counters at the internal irradiation population and personal dose assessment is considered in details

  14. Background radiation and individual dosimetry in the coastal area of Tamil Nadu (India)

    International Nuclear Information System (INIS)

    Matsuda, N.; Brahmanandhan, G. M.; Yoshida, M.; Takamura, N.; Suyama, A.; Koguchi, Y.; Juto, N.; Raj, Y. L.; Winsley, G.; Selvasekarapandian, S.

    2011-01-01

    South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2x7 m along the sea was found in the beach of Chinnavillai, Tamil Nadu, where the maximum ambient dose equivalent reached as high as 162.7 mSv y -1 . From the sands collected at the HBRA spot, the high-purity germanium semi-conductor detector identified six nuclides of thorium series, four nuclides of uranium series and two nuclides belonging to actinium series. The highest radioactivity observed was 43.7 Bq g -1 of Th-228. The individual dose of five inhabitants in Chinnavillai, as measured by the radiophotoluminescence glass dosimetry system, demonstrated the average dose of 7.17 mSv y -1 ranging from 2.79 to 14.17 mSv y -1 . (authors)

  15. A Finnish national code of practice for reference dosimetry of radiation therapy

    International Nuclear Information System (INIS)

    Kosunen, A.; Sipilae, P.; Jaervinen, H.; Parkkinen, R.; Jokelainen, I.

    2002-01-01

    Full text: A national Code of Practice (CoP) for reference dosimetry of radiation therapy in Finland will be established during 2002 and will be implemented from the beginning of 2003. The CoP will cover dosimetry of the conventional radiotherapy modalities used in Finland i.e. external radiotherapy with megavoltage photon and electron beams, external radiotherapy with low energy kilovoltage X-ray beams and brachytherapy. The formalisms for external radiation beam dosimetry are those of TRS 389. For brachytherapy the formalism will follow the general guidelines of TECDOC-1274. The CoP will be prepared by the SSDL of STUK in close co-operation with the Finnish radiotherapy physicists. For external beam radiotherapy, the main objective of the national Code of Practice for radiation therapy dosimetry is to maintain the achieved good level of consistency of the dosimetry procedures in external beam radiotherapy as the 'absorbed dose to water' based approach of TRS 389 is implemented in Finland. In the CoP the dosimetry the procedures are described for the whole dosimetry chain starting from the calibration of the ionisation chambers at the SSDL of STUK and ending to the calibration of the beam monitor ionisation chamber of a linear accelerator. For brachytherapy dosimetry the aim is to fix the national practice for reference air kerma rate calibrations both for radioactive sources and for well-type ionisation chambers. Although the dosimetry procedures are described independently of the SSDL service, CoP makes use of the special features of the calibration service offered by the SSDL of STUK. For ionisation chambers used for photon dosimetry the calibration factors for the user measurement chain are given not only for the actual reference beam quality ( 60 Co) but also for a set of user beam qualities. Furthermore, SSDL of STUK offers calibration services for plane parallel ionisation chambers in an electron beam of a user linac. For brachytherapy SSDL of STUK has

  16. Improved real-time dosimetry using the radioluminescence signal from Al2O3:C

    DEFF Research Database (Denmark)

    Damkjær, Sidsel Marie Skov; Andersen, Claus Erik; Aznar, Marianne

    2008-01-01

    15th International Conference on Solid State Dosimetry Location: Delft Univ Technol, Delft, NETHERLANDS Date: JUL 08-13, 2007 Abstract: Carbon-doped aluminum oxide (Al2O3:C) is a highly sensitive luminescence material for ionizing radiation dosimetry, and it is well established that the optically...... to greatly reduce the influence of shallow traps in the range from 0 to 3 Gy and the RL dose-rate measurements with a time resolution of 0. 1 s closely matched dose-rate changes monitored with in ionization chamber. (c) 2007 Elsevier Ltd. All rights reserved....

  17. Implementation of a remote system for monitoring of radiological areas of radiological areas

    International Nuclear Information System (INIS)

    Velazquez E, Walter; Galuppo G, Emiliano; Gutierrez G, Jorge; Reyes R, Jerson

    2008-01-01

    Full text: Introduction: The present work shows the development of a radiation remote monitoring system which control radiological areas in the principal facilities at CCHEN and the development in the last years to use this system called SMARR (Remote Radiological Area Monitoring System). This is an important issue in radiological safety is to know 'on line' and in a 'continuously way' the radiological variables of areas, especially if in these areas people manage radioactive sources or material, the monitoring system are operative on La Reina and Lo Aguirre Nuclear Centers. This 'knowledge' gets a good support to the radiological safety to safeguard the environment and people in the facilities. Nuclear Chilean Commission: Actually, this system is daily operating to register the background radiation and level operation, for example of the facilities research reactor, cyclone, irradiators, in order to probe the behaviors under operational requirements. The system was made using common Geiger Muller and NaI detectors. This signal is received, data by data, for a collector computer which uses a Labview program to do this displayed on a screen computer using graphics to show the activity on a radiological area, and when the lectures pass a setting value automatically the system send by e-mail and text message which also can be received for cell phones enabled for this for the supervisor. Each monitored facility is completely independent of each other and store a data backup, also every installation are monitoring with server computer, it's concentrating the information and allow to view it on line in real time, trough the intranet and internet network. In addition, the information is stored in the special report in the server and available for to do a statistics and identify the operation periods, and control of radioactive sources. The Industry: The radiological protection on industry is necessary today, the typical instrumentation on the industry is growing up in the

  18. Proceedings of the 5. Symposium on neutron dosimetry. Radiation protection aspects

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantities, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  19. Quantitative imaging for clinical dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bardies, Manuel [INSERM U601, 9 Quai Moncousu, 44093 Nantes (France)]. E-mail: manu@nantes.inserm.fr; Flux, Glenn [Department of Physics, Royal Marsden NHS Trust, Sutton (United Kingdom); Lassmann, Michael [Department of Nuclear Medicine, Julis-Maximilians University, Wuerzburg (Germany); Monsieurs, Myriam [Department of Health Physics, University of Ghent, 9000 Ghent (Belgium); Savolainen, Sauli [Department of Physical Sciences, University of Helsinki and HUS, Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland); Strand, Sven-Erik [Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University (Sweden)

    2006-12-20

    Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.

  20. The EURADOS/CONRAD activities on radiation protection dosimetry in medicine

    International Nuclear Information System (INIS)

    Vanhavere, F.; Struelens, L.; Bordy, J.M.; Daures, J.; Denozieres, M.; Buls, N.; Clerinx, P.; Carinou, E.; Clairand, I.; Debroas, J.; Donadille, L.; Itie, C.; Ginjaume, M.; Jansen, J.; Jaervinen, H.; Miljanic, S.; Ranogajec-Komor, M.; Nikodemova, D.; Rimpler, A.; Sans Merce, M.; D'Errico, F.

    2008-01-01

    Full text: This presentation gives an overview on the research activities that EURADOS coordinates in the field of radiation protection dosimetry in medicine. EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. EURADOS operates by setting up Working Groups dealing with particular topics. Currently funded through the CONRAD project of the 6th EU Framework Programme, EURADOS has working groups on Computational Dosimetry, Internal Dosimetry, Complex mixed radiation fields at workplaces, and Radiation protection dosimetry of medical staff. The latter working group coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated by sub-groups covering three specific areas: 1: Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2: Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons, especially to determine personal doses to cardiologists during cardiac catheterisation, but also in CT-fluoroscopy and some nuclear medicine developments (e.g. use of Re-188); and 3: Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (author)

  1. Cytogenetic techniques for biological indications and dosimetry of of radiation damages in humans

    International Nuclear Information System (INIS)

    Hadjidekova, V.

    2003-01-01

    The cytogenetic methods present a proved way for bio-monitoring and bio-dosimetry for persons, submitted to ionising radiation in occupational and emergency conditions. Their application complement and assist the evaluation of the physical dosimetry and takes in account the individual radiosensitivity of the organism. A comparative assessment is made of the cytogenetic markers for radiation damage of humans applied in Bulgaria. It is discussed the sensitivity of the methods and their development in the last years, as well as the basic concept for their application - the causal relationship between the frequency of the observation of cytogenetic markers in peripheral blood lymphocytes and the risk of oncological disease. The conventional analysis of dicentrics is recognised as a 'golden standard' for the quantitative assessment of the radiation damage. The long term persisting translocations reflect properly the cumulative dose burden from chronic exposure. The micronucleus test allows a quick screening of large groups of persons, working in ionising radiation environment. The combined application with centromeric DNA probe improves the sensitivity and presents a modern alternative of the bio-monitoring and bio-dosimetry. It is discussed the advantages of the different cytogenetic techniques and their optimised application for the assessment of the radiation impact on humans

  2. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas

    International Nuclear Information System (INIS)

    1990-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1990 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory -- Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release

  3. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  4. Internal dosimetry for occupationally exposed personnel in nuclear medicine

    International Nuclear Information System (INIS)

    Garcia, M.T.; Alfaro, L.M.M.; Angeles, C.A.

    2013-01-01

    Internal dosimetry plays an important role in nuclear medicine dosimetry control of personnel occupationally exposed, and that in recent years there has been a large increase in the use of radionuclides both in medical diagnosis as radiotherapy. But currently, in Mexico and in many parts of the world, this internal dosimetry control is not performed. The Instituto Nacional de lnvestigaciones Nucleares de Mexico (ININ) together with the Centro Oncologico de Toluca (ISEMMYM) have developed a simple and feasible methodology for monitoring of personnel working in these facilities. It was aimed to carry out the dosimetry of the personnel, due to the incorporation of I-131, using the spectrometric devices that the hospital has, a gamma camera. The first step in this methodology was to make a thyroid phantom to meet the specifications of the ninth ANSI. This phantom is compared under controlled conditions with RMC- II phantom used for system calibration of the ININ internal dosimetry (ACCUSCAN - Ll), and with another phantom developed in Brazil with ANSI specifications, in order to determine the variations in measurements due to the density of the material of each of the phantoms and adjust to the system ACCUSCAN, already certificate. Furthermore, necessary counts were performed with the gamma camera of the phantom developed at ININ, with a standard source of 133 Ba which simulates the energy of 131 I. With these data, were determined the counting efficiencies for a distance of 15 to 20 cm between the surface of the phantom and the the plate of the detectors. Another important aspect was to determine the lower limit of detection (LLD). In this paper we present the results obtained from the detectors calibration of the gamma camera of the hospital.

  5. Intercalibration of radiological measurements for surveillance purposes of the internal dosimetry laboratory coordinated by the IAEA

    International Nuclear Information System (INIS)

    Alfaro L, M.M.

    2002-07-01

    The ININ of Mexico participated in this intercomparison organized by the IAEA in 2000. The objective of this activity is that the dosimetry laboratories that participate can validate the programs of internal dosimetry, with the purpose of improving its capacity in the evaluation of the internal dose and have access to a mechanism to evaluate its dosimetry system under real conditions. The specific objectives of this intercomparison were: 1. To evaluate the participant's capacity to manage the measurements of individual monitoring in terms of the activity in the phantom. 2. To provide the access to the unique calibration resources that otherwise would not be available. 3. To compare the operation of several detection systems, the geometry, phantoms, calibration methods and methods for the evaluation of activity of the radionuclide used by each institution. 4. To provide the independent verification of the direct measurement methods of the dosimetry service. (Author)

  6. Advances in biomedical dosimetry

    International Nuclear Information System (INIS)

    1981-01-01

    quantity used in applied dosimetry. The problem is of enormous importance in medical dosimetry, because the refinement of radiotherapeutic techniques requires very accurate knowledge of the doses absorbed by the various tissues irradiated in the course of a treatment. - The use of fast neutron beams from cyclotrons in radiobiology and radiotherapy has also brought measurement problems, both in relation to the theoretical aspects and in relation to instrumentation. In this area users are in fact at more of a loss than the users of more conventional electron and photon beams, because there are virtually no reference scales as yet. Nevertheless, a highly active standardization programme is being pursued in the United States of America and in Europe among working groups set up by the medical physicists concerned. The studies undertaken in certain national laboratories should make it possible within a few years to set up a coherent dosimetric reference system adapted to this particularly complex sphere. - As far as international co-operation is concerned, efforts are being continued on behalf of the developing countries. The IAEA and WHO have set up a worldwide network of Secondary Standard Dosimetry Laboratories; the importance of these was stressed, and the national laboratories of the industrialized countries were urged to take an even more active part than heretofore in the operations of the network. (author)

  7. Report of the Intercomparison program by thermoluminescent dosimetry for Secondary Standard Dosimetry Laboratories

    International Nuclear Information System (INIS)

    Papadopulos, Susana

    2000-01-01

    In this report the results of an intercomparison program within a research coordinated program are presented. This is a third phase of the study that consisted in to evaluate the implementation of the new ICRU quantities for individual monitoring by the SSDLs, their capabilities to perform irradiations in different angles and the interpretation of the standard ISO 4370-3. This phase as well the first one was coordinated by Argentina through the Autoridad Regulatoria Nuclear that verified the performance of the participant laboratories. The SSDL of Argentina calibrated the dosimetric system to be used, and sent a set of tld dosimeters for irradiation at the SSDL or dosimetry laboratories of nine countries of latin america

  8. Review of the current deficiencies in personnel beta dosimetry, with recommendations

    International Nuclear Information System (INIS)

    Sherbini, S.; Porter, S.W.

    1983-06-01

    The report describes the design and use of personnel dosimeters used by the nuclear power industry to monitor occupational radiation exposure. It then shows why the monitoring method is inaccurate when personnel are exposed to beta particles. Then the report describes alternatives that would lead to improved measurements. The report also critiques the dosimetry processor testing criteria developed by the Health Physics Society Standards Committee. Survey instruments are shown often to be inaccurate when used to measure beta dose rates

  9. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  10. Dosicard: on-site evaluation of a new individual dosimetry system

    International Nuclear Information System (INIS)

    Delacroix, D.; Guelin, M.; Lyron, C.; Feraud, J.P.

    1995-01-01

    Dosicard is a new individual dosimetry system developed to monitor personnel working in the following fields: civil and military nuclear applications, medical environments and research centres: it can also be used to monitor mobile personnel. The system is based on the use of a credit-card sized format electronic badge. The associated computer environment enables management of the dosimetric data acquired. The characteristics of the system are presented in this paper together with an evaluation of the results of six month's use in a nuclear research centre. (author)

  11. The application of an automated thermoluminescence dosimetry system to environmental γ-dosimetry

    International Nuclear Information System (INIS)

    Jones, A.R.

    1977-07-01

    A personnel monitoring system comprising thermoluminescent dosimeters (TLDs) and an automatic TLD reader has been applied to environmental gamma dosimetry. For this purpose the accuracy of measurement at low exposures (10 to 100 mR) acquired over long periods (3 or 12 months) is important. To improve the accuracy and reliability of the system for this application the following steps were taken: the dosimeters were sensitized by irradiation with γ-rays and annealed while being irradiated with UV light; the sensitivity of each, identified dosimeter was measured and used to correct exposure measurements; the gasketted holders were modified to contain TLDs mounted on two identified plaques. Measurements of linearity, variability (with and without individual calibration) fading and energy dependence are presented. (author)

  12. Nevada Test Site 2001 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites; TOPICAL

    International Nuclear Information System (INIS)

    Y. E. Townsend

    2002-01-01

    Environmental monitoring data, subsidence monitoring data, and meteorology monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) (refer to Figure 1). These monitoring data include radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota data. Although some of these media (radiation exposure, air, and groundwater) are reported in detail in other Bechtel Nevada (BN) reports (Annual Site Environmental Report[ASER], the National Emissions Standard for Hazardous Air Pollutants[NESHAP] report, and the Annual Groundwater Monitoring Report), they are also summarized in this report to provide an overall evaluation of RWMS performance and environmental compliance. Direct radiation monitoring data indicate that exposure at and around the RWMSs is not above background levels. Air monitoring data indicate that tritium concentrations are slightly above background levels. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS has not been affected by the facility. Meteorology data indicate that 2001 was an average rainfall year: rainfall totaled 150 mm (5.9 in) at the Area 3 RWMS and 120 mm (4.7 in) at the Area 5 RWMS. Vadose zone monitoring data indicate that 2001 rainfall infiltrated less than one meter (3 ft) before being returned to the atmosphere by evaporation. Soil-gas tritium monitoring data indicate slow subsurface migration, and tritium concentrations in biota were lower than in previous years. All 2001 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility performance assessments

  13. State of art: Optically stimulated luminescence dosimetry – Frontiers of future research

    International Nuclear Information System (INIS)

    Yukihara, Eduardo G.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2014-01-01

    Since the commercial adoption of the optically stimulated luminescence (OSL) technique in dosimetry, almost 20 years ago, we have seen major advances in the deployment of OSL dosimeters in different areas, including personal, medical, and space dosimetry. The objective of this paper is to provide a critical overlook at the OSL technique from three different points of view: strengths, challenges and opportunities. We discuss factors that made the OSL technique successful: its simplicity, accuracy, wide dynamic range of measured dose, ease for automation, re-read capability, ability to perform imaging, and the availability of diverse instruments and materials. We look into problems that were overcome and others that remain in several areas of new applications into which OSL has expanded in the past 10 years, such as medical, space, neutron and accident dosimetry. Finally, we discuss unexplored possibilities, new driving forces, and open questions. We hope the broad overview presented here will encourage more discussion and stimulate the research that will advance our fundamental understanding of the OSL process. - Highlights: • Critical overlook of the OSL technique is presented. • Factors that made the OSL technique successful are discussed. • New applications in medical, space and accident dosimetry are discussed. • Unexplored possibilities, new driving forces, and open questions are presented

  14. Helium production measurements for neutron dosimetry and damage correlations

    International Nuclear Information System (INIS)

    Farrar, H. IV; Lippincott, E.P.

    1978-01-01

    Helium accumulation fluence monitors (HAFM's), consisting of miniature vanadium capsules containing small, accurately-known amounts of 10 B or 6 Li, are being used routinely for neutron dosimetry measurements in breeder reactor environments. Additionally, solid wires of Al, Fe and Cu have been irradiated by 14.8-MeV neutrons from the d-T reaction, and measurements of the helium production along these wires have given detailed neutron fluence profiles. Additional materials with relatively high (n,α) cross sections are being tested in a wide variety of neutron environments to select HAFM sets that will provide spectral information by unfolding techniques. The mass spectrometric helium measurement technique has been demonstrated to produce results with better than 2% (1 sigma) absolute accuracy. Intercomparisons with other laboratories have demonstrated good correlations with radiometric and fission chamber dosimetry results

  15. CREAM - a Cosmic Radiation Effects and Activation Monitor for space experiments: Pt. 1

    International Nuclear Information System (INIS)

    Mapper, D.; Stephen, J.H.; Farren, J.; Stimpson, B.P.; Bolus, D.J.; Ellaway, A.M.

    1987-12-01

    A detailed account is given of the design and construction of the experimental CREAM packages, intended for flight in the mid-deck area of the Space Transport System (Shuttle) Mission in 1986. The complete experiment involved; 1) a self-contained and battery powered activation monitor for measuring energy losses of charged particles; 2) CR-39 and Kapton polymer solid state nuclear track detectors for the detection of ionising particles; 3) metal foils of nickel, titanium and gold for neutron monitoring; and 4) thermoluminescent detectors for dosimetry measurements of the radiation background. The circuit design and detailed functioning of the active monitor is fully described, together with a complete discussion of the principles and operation of the passive monitors. (author)

  16. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  17. Film dosimetry for IMRT: sensitivity corrections

    International Nuclear Information System (INIS)

    Suchowerska, N.; Hoban, P.; Davison, A.; Metcalfe, P.

    2000-01-01

    Full text: The trend towards conformal, dynamic and intensity modulated radiotherapy treatments has furthered the need for true integrating dosimetry. In traditional radiotherapy, film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose, has been associated with several variables. These include the effects of film specific sensitivity, direction of exposure, chemical processing and film scanner sensitivity. In this study, a procedure is developed to account for these variables, with a particular view to film being used as a dosimeter for conformal treatments. An effective sensitometric curve was established by exposing part of a single sheet of film to known doses. All films were processed together and scanned using a DuoscanT1200 transmission scanner, resulting in 12 bit image files. The images were analysed using Osiris software and the results fitted to the modified Williamson equation: P P s (l - 10 αD ) This yields values of α [film sensitivity], and P s [saturation pixel value], allowing individual dosimetry films to be normalised to this sensitometric calibration curve. For validation, a piece of Kodak X Omat-V film was sealed in a head phantom and exposed to a total of 51 IMRT fields, delivered from 6 gantry angles. The rest of the sheet of film was resealed and exposed to four known doses, providing sensitometric data, specific to this exposure. All films were then processed, scanned and analysed as described above. Observed variations in serial films exposed to 50cGy is in the order of 9% [mean 25.0,standard deviation = 3.2]. The automatic gain of the scanner system typically contributed 4% variation and needs to be carefully monitored. Results indicate that by using the sensitometric data from each exposure, the collective errors can be minimised. The IMRT exposure results confirm that the above process is viable for use in dosimetry for conformal radiation therapy. Copyright (2000) Australasian

  18. Techniques for high dose dosimetry in industry, agriculture and medicine. Proceedings of a symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    In radiation processing, it is important that the irradiated products are reliable and safe. For processes that impact directly on public health, dosimetry provides a formal means of regulation. For other applications, measurements are indispensable for process control to improve quality and the measurements have to be standardized. Thus, dosimetry is an essential part of quality standards for radiation processes. In the developing world, establishment of such quality standards is only in the embryonic stage, and the IAEA should and does play a role in the development and implementation of these standards. The IAEA initiated a programme of high dose dosimetry in 1977 to accomplish dose standardization on an industrial scale, to promote dosimetry as a quality control measure in radiation processing, and to help develop new dosimetry techniques. Since dosimetry has such a key role in these processes, the IAEA organized this international symposium to provide a forum for presentation and discussion of up-to-date developments in this field. Since the International Symposium on High Dose Dosimetry for Radiation Processing held in 1990 the field of dosimetry has deepened and broadened. There is a definite shift towards quality assurance, which calls for dependable dosimetry systems with well established traceability to national or international standards. Also, many new applications of radiation have been developed and for these new and innovative dosimetry methods are needed. This symposium has provided a forum for the discussion of many of these developments and consideration of the outstanding issues in these vital areas Refs, figs, tabs

  19. Techniques for high dose dosimetry in industry, agriculture and medicine. Proceedings of a symposium

    International Nuclear Information System (INIS)

    1999-03-01

    In radiation processing, it is important that the irradiated products are reliable and safe. For processes that impact directly on public health, dosimetry provides a formal means of regulation. For other applications, measurements are indispensable for process control to improve quality and the measurements have to be standardized. Thus, dosimetry is an essential part of quality standards for radiation processes. In the developing world, establishment of such quality standards is only in the embryonic stage, and the IAEA should and does play a role in the development and implementation of these standards. The IAEA initiated a programme of high dose dosimetry in 1977 to accomplish dose standardization on an industrial scale, to promote dosimetry as a quality control measure in radiation processing, and to help develop new dosimetry techniques. Since dosimetry has such a key role in these processes, the IAEA organized this international symposium to provide a forum for presentation and discussion of up-to-date developments in this field. Since the International Symposium on High Dose Dosimetry for Radiation Processing held in 1990 the field of dosimetry has deepened and broadened. There is a definite shift towards quality assurance, which calls for dependable dosimetry systems with well established traceability to national or international standards. Also, many new applications of radiation have been developed and for these new and innovative dosimetry methods are needed. This symposium has provided a forum for the discussion of many of these developments and consideration of the outstanding issues in these vital areas

  20. Dosimetry of β extensive sources

    International Nuclear Information System (INIS)

    Rojas C, E.L.; Lallena R, A.M.

    2002-01-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of β extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  1. From 'Roentgen' to 'effective dose'. Cooperation of PTR/PTB with Standard Committee Radiology in the development of radiation protection dosimetry

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietze, G.; Hohlfeld, K.

    1995-01-01

    The development of quantities and units in the field of radiation protection dosimetry is demonstrated by some examples. This development is strongly connected with work performed at the PTR/PTB and the work of the ''Normenausschuss Radiologie (NAR) im DIN''. In the following the new radiation protection operational quantities are described which have been recommended by the international commissions ICRU and ICRP for use in area and individual monitoring of external radiation. It is aimed to introduce these quantities in Germany in 1995 - also in legal metrology. (orig.) [de

  2. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  3. Accreditation and training on internal dosimetry in a laboratory network in Brazil: an increasing demand.

    Science.gov (United States)

    Dantas, B M; Dantas, A L A; Acar, M E D; Cardoso, J C S; Julião, L M Q C; Lima, M F; Taddei, M H T; Arine, D R; Alonso, T; Ramos, M A P; Fajgelj, A

    2011-03-01

    In recent years, Brazilian Nuclear Programme has been reviewed and updated by government authorities in face of the demand for energy supply and its associated environmental constraints. The immediate impact of new national programmes and projects in nuclear field is the increase in the number of exposed personnel and the consequent need for reliable dosimetry services in the country. Several Technical Documents related to internal dosimetry have been released by the International Atomic Energy Agency and International Commission on Radiological Protection. However, standard bioassay procedures and methodologies for bioassay data interpretation are still under discussion and, in some cases, both in routine and emergency internal monitoring, procedures can vary from one laboratory to another and responses may differ markedly among Dosimetry Laboratories. Thus, it may be difficult to interpret and use bioassay data generated from different laboratories of a network. The main goal of this work is to implement a National Network of Laboratories aimed to provide reliable internal monitoring services in Brazil. The establishment of harmonised in vivo and in vitro radioanalytical techniques, dose assessment methods and the implementation of the ISO/IEC 17025 requirements will result in the recognition of technical competence of the network.

  4. Recent research into thermoluminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, T [National Inst. of Radiological Sciences, Chiba (Japan)

    1979-04-01

    The trend of basic research in thermoluminescent dosimetry (TLD), the results, and developing fields in which it can be applied are reported. This trend is outlined from the viewpoint fields of application, a new trend in TLD readers, the conditions of development of new photogenic substances, and research in the radiation characteristics of photogenic substances (radiosensitivity to particle rays and ultraviolet rays, dose rate dependence, temperature dependence at irradiation, and ..gamma.. ray energy dependence). Utilization of TLD in the medical field for measurement of environmental radiation and as a monitor for workers exposed to radiation is discussed. An international comparison of dose was necessary in order to prove its universal validity.

  5. Monitoring and studies of environmental cumulative dose of Guangdong Da Ya Bay nuclear-power station by thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Wan Yusong; Li Shili; Yang Lin; Feng Zhanglin; Kong Lingfeng; Yu Jinglan

    1999-01-01

    The author presents the environmental γ radiation routine monitoring by TLD in Guangdong Da Ya Bay Nuclear Power Station and its peripheral 50 km area, which has been put into commercial operation since 1994. The year's monitoring result indicates that there is no obvious change of the total environmental γ radiation in Da Ya Bay Nuclear Power Station and its peripheral 50 km area. But the influence of gas release γ radiation was monitored in 1995 at the monitoring points in the area of 0∼1 km from the nuclear power station

  6. Bayesian Methods for Radiation Detection and Dosimetry

    International Nuclear Information System (INIS)

    Peter G. Groer

    2002-01-01

    We performed work in three areas: radiation detection, external and internal radiation dosimetry. In radiation detection we developed Bayesian techniques to estimate the net activity of high and low activity radioactive samples. These techniques have the advantage that the remaining uncertainty about the net activity is described by probability densities. Graphs of the densities show the uncertainty in pictorial form. Figure 1 below demonstrates this point. We applied stochastic processes for a method to obtain Bayesian estimates of 222Rn-daughter products from observed counting rates. In external radiation dosimetry we studied and developed Bayesian methods to estimate radiation doses to an individual with radiation induced chromosome aberrations. We analyzed chromosome aberrations after exposure to gammas and neutrons and developed a method for dose-estimation after criticality accidents. The research in internal radiation dosimetry focused on parameter estimation for compartmental models from observed compartmental activities. From the estimated probability densities of the model parameters we were able to derive the densities for compartmental activities for a two compartment catenary model at different times. We also calculated the average activities and their standard deviation for a simple two compartment model

  7. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  8. Personnel Monitoring Department - DEMIN

    International Nuclear Information System (INIS)

    1989-01-01

    The activities and purposes of the Personnel Monitoring Dept. of the Institute of Radioprotection and Dosimetry of the Brazilian CNEN are presented. A summary of the personnel monitoring service is given, such as dosemeters supply, laboratorial inspections, and so on. The programs of working, publishing, courses and personnel interchange are also presented. (J.A.M.M.)

  9. Characterising an aluminium oxide dosimetry system.

    Science.gov (United States)

    Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor

    2015-09-01

    In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.

  10. Studies in dosimetry using stimulated exoelectron emission

    International Nuclear Information System (INIS)

    Petel, Maurice.

    1976-06-01

    Some applications of the stimulated exoelectron emission in radiation dosimetry are discussed. The principles which govern the phenomenon are presented. The apparatus, in particular the counter, used to monitor the emission is discussed with reference to both optical and thermal stimulation. The correlation existing between thermoluminescence and thermally stimulated exoelectron emission were studied in both lithium fluoride and aluminium oxide. Furthermore, aluminium oxides from different sources were examined, and one of these, chosen to investigate the dosimetric properties of this material using both methods of stimulation [fr

  11. Dose measurements in dental radiology using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Chiara, Ana Claudia M. de; Costa, Alessandro M.; Pardini, Luiz Carlos

    2009-01-01

    The aim of this work was the implementation of a code of practice for dosimetry in dental radiology using the technique of thermoluminescent dosimetry. General principles for the use of thermoluminescent dosimeters were followed. The irradiations were performed using ten X-ray equipment for intra-oral radiography and an X-ray equipment for panoramic radiography. The incident air kerma was evaluated for five different exposure times used in clinical practice for intra-oral radiographs. Using a backscatter factor of 1.2, it was observed that approximately 40% of the entrance skin dose values found for intra-oral radiographs are above the diagnostic reference level recommended in national regulation. Different configurations of voltage and current were used representing the exposure as a child, woman and man for panoramic radiographs. The results obtained for the air kerma area product were respectively 53.3 +- 5.2 mGy.cm 2 , 101.5 +- 9.5 mGy.cm 2 and 116.8 +- 10.4 mGy.cm 2 . The use of thermoluminescent dosimetry requires several procedures before a result is recorded. The use of dosimeters with ionization chambers or semiconductors provides a simple and robust method for routine measurements. However, the use of thermoluminescent dosimetry can be of great value to large-scale surveys to establish diagnostic reference levels. (author)

  12. Implementation of a OSL dosimetry laboratory at IRD/CNEN-BR

    International Nuclear Information System (INIS)

    Moura, Jose; Alencar, Marcus A. Vallim de; Mauricio, Claudia L.P.; Hunt, John

    2005-01-01

    The optically stimulated luminescence (OSL) it is a phenomenon characterized by the luminous emission of an insulating material or semiconductor, during your exhibition to the light, after it being previously exposed to the ionizing radiation. This phenomenon has been used more and more in the dosimetry of the ionizing radiations, why the intensity OSL of some materials is proportional to the absorbed dose in these. The processes OSL and thermoluminescence (TL) they only differ in the stimulation form for light emission. One of the advantages of the OSL process in relation to the traditional technique of TL dosimetry is the no complete destruction of the information of the absorbed dose in the material during the reading. Following this world tendency, the External Individual Monitoring Service of the Institute of Radioprotection and Dosimetry (SEMEX/IRD) implemented the OSL dosimetry laboratory. The acquired reader was the reader model LAUGHTER TL/OSL-GIVE-15B/C. With that reader it is possible to do readings TL and OSL. After the installation of the equipment in a darkroom with temperature and humidity controlled, they were made the preliminary tests with the equipment and the laboratory became operational. After this first stage, they were initiate the studies with the Al 2 O 3 :C dosimeters by Harshaw under the denomination TLD 500. The reading parameters and thermal treatment were optimized to study the applicability of OSL technique with the TLD 500 dosimeter for the use in environmental monitoring. It was also verified the linearity of the system for high doses (10 mGy-1 Gy) seeking your use in radiotherapy, as well as the effect of the thermal treatment in the OSL signal of the Al 2 O 3 :C dosimeter. The results prove the possibility of use of this system in environmental monitoring. The reproductivity of the system for the air kerma value of 100 mGy, considering a degree of confidence of 95%, was to 4,8% for OSL readings and 5,6% for TL. In the two cases

  13. REMOTE AREA RADIATION MONITORING (RARM) ALTERNATIVES ANALYSIS

    International Nuclear Information System (INIS)

    NELSON RL

    2008-01-01

    The Remote Area Radiation Monitoring (RARM) system will be used to provide real-time radiation monitoring information to the operations personnel during tank retrieval and transfer operations. The primary focus of the system is to detect potential anomalous (waste leaks) or transient radiological conditions. This system will provide mobile, real-time radiological monitoring, data logging, and status at pre-selected strategic points along the waste transfer route during tank retrieval operations. The system will provide early detection and response capabilities for the Retrieval and Closure Operations organization and Radiological Control personnel

  14. A review of lyoluminescence dosimetry and a new readout method using liquid scintillation techniques

    International Nuclear Information System (INIS)

    Ziemer, P.L.; Hanig, R.; Fayerman, L.K.

    1978-01-01

    Lyoluminescence dosimetry is useful as a personnel monitor and also as a neutron dosimeter. A review of lyoluminescence is given including readout systems, the machanisms of light emission, radiometric characteristics of lyoluminescence dosimeters, factor affecting response and liquid scintillation lyoluminscence readout

  15. Proceedings of the III international workshop 'Actual problems of dosimetry (15 years after the Chernobyl accident)'

    International Nuclear Information System (INIS)

    Milyutin, A.A.; Chudakov, V.A.; Berezhnoj, A.V.

    2001-10-01

    Materials grouped to three main issues: normative, metrological and technical support of dosimetric and radiometric control; biological dosimetry and markers of radiation effects; monitoring and reconstruction of radiation doses at radiation accidents

  16. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  17. Secondary standard dosimetry laboratory (SSDL)

    International Nuclear Information System (INIS)

    Md Saion bin Salikin.

    1983-01-01

    A secondary Standard Dosimetry Laboratory has been established in the Tun Ismail Research Centre, Malaysia as a national laboratory for reference and standardization purposes in the field of radiation dosimetry. This article gives brief accounts on the general information, development of the facility, programmes to be carried out as well as other information on the relevant aspects of the secondary standard dosimetry laboratory. (author)

  18. Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.; Musijachenko, A.

    2004-01-01

    Development of the nation-wide network for monitoring and registration of individual doses is being in progress in Ukraine. The need for urgent action is caused by the fact, that despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralized dose accounting system in Ukraine, existing dosimetry services operate obsolete manual TLD readers and no methodological unity is observed by the dosimetry services. Presently the mixed dosimetric monitoring is practiced in Ukraine. Nuclear power plants and some major nuclear facilities have their own dosimetry services responsible for dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by territorial dosimetry laboratories affiliated to sanitary and epidemiology supervision bodies. In total these services cover about 38,000 occupationally exposed workers, including 5,500 in medicine, 16,400 employees of five nuclear power plants and about 16,000 workers dealing with other sources of occupational exposure (industry, research, military). It is prescribed by the governmental decree that three-level united state system assigned to covering all aspects of efficient dosimetric monitoring should be established. The tasks of the system, in particular, are: securing methodical unity of individual dosimetric monitoring; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programs; development and support of information infrastructure for logging, storage and access to data on individual dosimetric monitoring, in particular - keeping the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. In its development, the national system will be guided by international experience and will be established according to the best practices

  19. Experience in the treatment of IMRT in prostate cancer. Planning, dosimetry and quality control

    International Nuclear Information System (INIS)

    Gomez Barrado, A.; Garcia Vicente, F.; Fernandez Bedoya, V.; Bermudez Luna, R.; Perez Gonzalez, L.; Torres Escobar, J. J.

    2011-01-01

    The aim of this study is to review the treatment of prostate cancer at our center. A description of the entire procedure, involving clinical dosimetry, and procedures for verification of treatment, including physical dosimetry and parallel computing system MSure (Standard Imaging, Inc., Middleton) as part of these procedures. This system is based on the model published by trifuente Yang et al. (Yang et al. 2002) for testing treatments regarding the number of monitor unit (MU) given. In addition, this software has a module for the testing of treatments for intensity modulated radiotherapy (IMRT), which will be analyzed in this study.

  20. Dosimetric monitoring in Ukraine - present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2005-01-01

    Full text: Ukraine is the country which utilizes radiation in many peaceful areas. So, nuclear energy sector includes 15 power units (including two new units commissioned in 2004), nuclear fuel cycle also include uranium mines, radiation sources are widely used in industry, science and medicine. As a result, about 50,000 occupationally exposed workers require dosimetric monitoring. However, presently dosimetry services in Ukraine cover only about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca. 12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services, responsible for dosimetric monitoring in industry and medicine operate in 13 of 25 oblasts (regions) of Ukraine. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38 % to 100 % depending on the oblast. With rare exception, instrumentation is represented by outdated manual TLD systems (inaccurate and insufficiently sensitive) capable of measurement of deep photon dose only; no personal monitoring of beta and neutron exposure is possible now. Quality assurance is limited to the annual metrological attestation of the dosimetric instruments. No information exchange infrastructure and dosimetric registry are in place. The dosimetric data is stored in home-made data environments or even in paper log-books, no data on individual doses is conveyed to central depository, which could be easily accessible for regulating authorities. Although the standing law requires elaboration of the United System for monitoring and registration individual doses, little was done so far, mainly due to lack of domestic funding. However, intention is strong to build such network in accordance with the best practice, covering not only the aspects of physical measurement and data storage, but also quality assurance, accreditation programs and training of the local personnel

  1. Personal Doses Recorded by Service of Personal Dosimetry

    International Nuclear Information System (INIS)

    Mihai, F.; Gheorghiu, A.; Stochioiu, A.; Udup, E.

    2009-01-01

    In this work we present occupational exposure statistics on: number of workers on different dose ranges; average of the mean annual doses (MAD) over the period 2000 - 2007 on all monitored workers as well as on those who have been received doses over the minimum detection limit (MDL). The statistic is made on different types of nuclear laboratories. The data are obtained on almost 1000 workers occupational exposure to different sources of radiations (gamma and X-ray) and monitored by Photo dosimetry Survey Unit, IFIN - HH. These results point out the evolution of the individual doses received during eight years and can be used to analyse the need of radiation protection in different nuclear facilities from Romania

  2. Neutrons individual monitoring: 18 years of experience

    International Nuclear Information System (INIS)

    Goncalves, Sergio Alves; Mauricio, Claudia Lucia de Pinho; Moura Junior, Jose; Martins, Marcelo Marques; Meira, Nilton Ferreira; Diz, Ricardo; Seda, Rosangela Pinto Guimaraes

    2002-01-01

    The Thermoluminescent Dosimetry Laboratory of the Departamento de Monitoracao Individual of the Instituto de Radioprotecao e Dosimetria (LDT/DEMIN/IRD) is the only one in Brazil that operates routinely a whole body external individual monitoring service for neutrons. An albedo type monitor is used with thermoluminescent detectors pairs of 6 LiF:Mg,Ti and 7 LiF:Mg,Ti, made by Harshaw/Bicron and named, respectively, TLD-600 and TLD-700. In its 18 years of activities, the laboratory has ever made a great effort to be continuously updated. Equipment and procedures have been updated and optimized in order to guarantee the quality of all measurements. Nowadays, the neutron individual monitoring service evaluates doses of about 300 workers occupationally exposed to neutrons in several facilities of different areas of Brazil. The system history and the results obtained by the service in international intercomparisons and in its routine monitoring are presented in this work. (author)

  3. Neutron area monitor with TLD pairs

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Borja H, C. G.; Valero L, C.; Hernandez D, V. M.; Vega C, H. R.

    2011-11-01

    The response of a passive neutron area monitor with pairs of thermoluminescent dosimeters has been calculated using the Monte Carlo code MCNP5. The response was calculated for one TLD 600 located at the center of a polyethylene cylinder, as moderator. When neutrons collide with the moderator lose their energy reaching the TLD with thermal energies where the ambient dose equivalent is calculated. The response was calculated for 47 monoenergetic neutron sources ranging from 1E(-9) to 20 MeV. Response was calculated using two irradiation geometries, one with an upper source and another with a lateral source. For both irradiation schemes the response was calculated with the TLDs in two positions, one parallel to the source and another perpendicular to the source. The advantage of this passive neutron monitor area is that can be used in locations with intense, pulsed and mixed radiation fields. (Author)

  4. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011; Resultados del servicio de dosimetria externa del CPHR durante el bienio 2010-2011

    Energy Technology Data Exchange (ETDEWEB)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia, E-mail: daniel@cphr.edu.cu [Laboratorio de Dosimetria Externa (LDE), Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements.

  5. Current status of personnel monitoring for beta particles

    International Nuclear Information System (INIS)

    Plato, P.; Miklos, J.

    1983-01-01

    From 1975 to 1982, a concerted effort was made to develop a uniform procedure to test the performance of personnel dosimetry processors throughout the United States. The heart of this effort is a standard developed by the Health Physics Society Standards Committee (HPSSC) and adopted by the American National Standards Institute (ANSI) as ANSI N13.11-1982. The US Nuclear Regulatory Commission (NRC) sponsored a five year pilot study of this Standard which included three trial tests in which approximately 80 dosimetry processors participated. The Standard has made several contributions to the art and science of personnel monitoring for beta particles. First, the Standard defines test categories for beta particles and mixtures of beta particles plus gamma rays in addition to test categories for other types of radiation. Second, it defines a reference beta-particle source for test purposes. Third, it provides test criteria which are used to determine acceptable performance by a processor. The pilot study provided information on the state of the art of personnel monitoring within the bounds of the Standard. In addition, since the pilot study was advertised as the forerunner of a future mandatory certification program for dosimetry processors throughout the United States, considerable attention was given to personnel monitoring in general, and beta particles in particular. This paper discusses specific contibutions of the HPSSC/ANSI Standard and the pilot study to beta-particle dosimetry. The results of the three tests of the pilot study are summarized. The paper also amplifies on the needs to define the monitoring particle sources clearly

  6. Theoretical basis for dosimetry

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  7. Wide area continuous offender monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hoshen, J. [Lucent Technologies (United States); Drake, G. [New Mexico Dept. of Corrections, Santa Fe, NM (United States); Spencer, D. [Sandia National Labs., Albuquerque, NM (United States)

    1996-11-01

    The corrections system in the U.S. is supervising over five million offenders. This number is rising fast and so are the direct and indirect costs to society. To improve supervision and reduce the cost of parole and probation, first generation home arrest systems were introduced in 1987. While these systems proved to be helpful to the corrections system, their scope is rather limited because they only cover an offender at a single location and provide only a partial time coverage. To correct the limitations of first-generation systems, second-generation wide area continuous electronic offender monitoring systems, designed to monitor the offender at all times and locations, are now on the drawing board. These systems use radio frequency location technology to track the position of offenders. The challenge for this technology is the development of reliable personal locator devices that are small, lightweight, with long operational battery life, and indoors/outdoors accuracy of 100 meters or less. At the center of a second-generation system is a database that specifies the offender`s home, workplace, commute, and time the offender should be found in each. The database could also define areas from which the offender is excluded. To test compliance, the system would compare the observed coordinates of the offender with the stored location for a given time interval. Database logfiles will also enable law enforcement to determine if a monitored offender was present at a crime scene and thus include or exclude the offender as a potential suspect.

  8. Eurados trial performance test for photon dosimetry

    DEFF Research Database (Denmark)

    Stadtmann, H.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    Within the framework of the EURADOS Action entitled Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation, trial performance tests for whole-body and extremity personal dosemeters were carried out. Photon, beta and neutron dosemeters were considered....... This paper summarises the results of the whole-body photon dosemeter test. Twenty-six dosimetry services from all EU Member States and Switzerland participated. Twelve different radiation fields were used to simulate various workplace irradiation fields. Dose values from 0.4 mSv to 80 mSv were chosen. From...

  9. Reconstructive dosimetry for cutaneous radiation syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.M.A.; Lima, A.R.; Degenhardt, Ä.L.; Da Silva, F.C.A., E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Valverde, N.J. [Fundacao Eletronuclear de Assistencia Medica, Rio de Janeiro, RJ (Brazil)

    2015-10-15

    According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry. (author)

  10. Technical requirements for implementation of an individual monitoring service for evaluation of operational quantity HP(10) using thermoluminescent dosimetry; Requisitos tecnicos para a implantacao de um servico de monitoracao individual externa de corpo inteiro para fotons utilizando dosimetria termoluminescente

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, Adelaide Benedita Armando

    2016-11-01

    This work aims to establish technical requirements for the development of a TLDs system for the assessment of operational quantity H{sub P}(10), in order to implement an external individual monitoring service in countries who do not have. This allows a better understanding of the technic and the thermoluminescent dosimetry system, thus contributing to identify the technical criteria to be followed by a dosimetry laboratory and evaluation of the dosimetric system performance. For this, the review of the specific literature of the dosimetry field was conducted and later the type and performance tests that must be followed by a dosimetric system were reproduced in practice. In additional was made a analysis of internationals standards norms and the technical regulation used in Brazil, to define the essentials type testes to a dosimetric system. To check the performance of a dosimetry system, a performance analysis of the Brazilian TLDs system was carried out over the past 6 years using the trumpet curve, where it was observed that most of TLDs system, in this review period, were approved and have excellent performance. The technical requirements for the development of a thermoluminescent dosimetry system ensure that the system provides technically reliable results and allow demonstration of compliance with the standard criteria established by national and international standards, and the implementation of the dosimetry system, is verified the compliance of the annual doses limits set for occupationally exposed. (author)

  11. The dielectric track and thermoluminescent detectors applied to neutron dosimetry in personnel monitoring

    International Nuclear Information System (INIS)

    Mebhah, D.

    1984-03-01

    The personnal dosimeter for neutron based on the detection of fission fragments from 237 Np and 232 Th by a polycarbonate 10 gm, and lithium fluorite 6 LIF/ 7 LIF, allow to cover an energy spectrum from 0.05 eV to 14 MeV with a easy neutron gamma discrimination. In criticality dosimetry, the energy spectrum of the incident neutrons can be defined by two components: the fast component by E b exp(-ae) with E between 0.1 and 14 MeV, a and b determined by a combination of 237 Np and 232 Th track detector responses, and the epithermal component in 1/E, the thermal component having a minor contribution to the total equivalent dose. We took into account the body influence on the detectors response by introducing effective cross section. The equivalent dose obtained by this dosimeter is 20% overestimated in low doses dosimetry. The interpretation of the detectors responses is based on the definition of a factor and a calibration parameter for each zone in which the spectrum is constant. The knowledge of this parameter for individual dosimeters allows to account for the variations of the conditions of calibration

  12. The role of the national physical laboratory in monitoring and improving dosimetry in UK radiotherapy

    International Nuclear Information System (INIS)

    McEwen, M.R.; Duane, S.; Thomas, R.A.S.; Rosser, K.E.

    2001-01-01

    There are approximately 60 radiotherapy centres in the UK. In 1999, these centres carried out over 102,000 treatments in 1.2 million fractions. These centres are organised by IPEM into eight geographical regions for the purpose of inter-departmental audits, which have been carried out on a regular basis to check the uniformity of dosimetry, treatment planning, record keeping, etc. Thwaites et al (1992) carried out a dosimetric intercomparison of megavoltage photon beams in all UK radiotherapy centres obtaining a mean value for the ratio audit/local dose of 1.003 with a standard deviation of 1.5%. The present programme covers dosimetry of megavoltage photons and electrons and low and medium energy (10-300 kV) photons. Megavoltage photon audits have the longest history, while electron audits began in 2000 and kV audits are only at the pilot stage

  13. Biological and clinical dosimetry, July 1, 1964 to December 31, 1984. Final report

    International Nuclear Information System (INIS)

    Laughlin, J.S.; Zeitz, L.

    1986-01-01

    The goal was to develop systems for the determination of absorbed dose in biological research and clinical applications. The primary method under study is the local absorbed dose calorimeter. In addition, secondary dosimetric systems such as ionization chambers, chemical dosimeters and thermoluminescent dosimeters (TLD) are being developed and applied to provide an absolute basis for the evaluation and comparison of experiments, treatments and other procedures using radiation. In keeping with these objectives this project has accomplished significant advances in the following areas: (1) local absorbed dose calorimetry; (2) neutron dosimetry; (3) dosimetry of ultra-high intensity radiation sources; (4) solid state detector and germanium gamma camera program; (5) dosimetry for brachytherapy; and (6) ''non-isolated sensor'' calorimeters

  14. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  15. Dosimetric quality assurance interpreted for ISO 17025 in public health England's personal dosimetry service

    International Nuclear Information System (INIS)

    Gilvin, P.J.; Gibbens, N.J.; Baker, S.T.

    2016-01-01

    Many individual monitoring services (IMSs) have long experience in delivering high-quality dosimetry, and many follow rigorous quality assurance (QA) procedures. Typically, these procedures have been developed through experience and are highly effective in maintaining high-quality dose measurements. However, it is not always clear how the range of QA procedures normally followed by IMSs maps on to the various requirements of ISO 17025. The Personal Dosimetry Service of Public Health England has interpreted its QA procedures both in operating existing services and in developing a new one. (authors)

  16. RPL dosimetry. Radiophotoluminescence in health physics

    International Nuclear Information System (INIS)

    Perry, J.A.

    1987-01-01

    The luminescence phenomena described in this book are those that are most likely to be of practical use; RPL is particularly suitable for the measurement of absorbed dose resulting from interactions with ionising radiations. The book examines the phenomena of radio-photoluminescence and proceeds to describe particular materials which exhibit the necessary fluorescence, their behaviour, dosimetric properties and the wide range of alternative measurement techniques that may be applied to them in a variety of monitoring environments. The emphasis is primarily on implementation in health physics as a personal and environmental monitor and particular reference is made to the use of RPL as a research tool for radiotherapy treatment planning and in the context of civil defence. The author reviews the design, operation and basic operational principles of some of the readers currently in service or being developed. The logistics of operating small and large monitoring services are considered and there is a useful comparison between glass, thermoluminescence and film methods of dosimetry to enable potential users to evaluate the merits of each from a theoretical and practical point of view. (author)

  17. Personal dosimetry in Kazakhstan

    International Nuclear Information System (INIS)

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  18. UK guidance on the management of personal dosimetry systems for healthcare staff working at multiple organizations.

    Science.gov (United States)

    Rogers, Andy; Chapple, Claire-Louise; Murray, Maria; Platton, David; Saunderson, John

    2017-11-01

    There has been concern expressed by the UK regulator, the Health & Safety Executive, regarding the management of occupation dose for healthcare radiation workers who work across multiple organizations. In response to this concern, the British Institute of Radiology led a working group of relevant professional bodies to develop guidance in this area. The guidance addresses issues of general system management that would apply to all personal dosimetry systems, regardless of whether or not the workers within that system work across organizational boundaries, along with exploring efficient strategies to comply with legislation where those workers do indeed work across organizational boundaries. For those specific instances, the guidance discusses both system requirements to enable organizations to co-operate (Ionising Radiation Regulations 1999 Regulation 15), as well as specific instances of staff exposure. This is broken down into three categories-low, medium and high risk. A suggested approach to each is given to guide employers and their radiation advisers in adopting sensible strategies for the monitoring of their staff and the subsequent sharing of dosimetry data to ensure overall compliance with both dose limits and optimization requirements.

  19. Gamma dosimetry of the uranium deposit in Sao Jose de Espinharas, Paraiba, Brazil

    International Nuclear Information System (INIS)

    Silva, Alberto Antonio da; Santos Junior, Jose Araujo dos; Cunha, Andre Felippe Vieira da; Amaral, Romilton dos Santos; Oliveira, Iane Andrade de; Bezerra, Jairo Dias; Silva, Flavio Ferreira da

    2013-01-01

    Radioecology studies contribute to the monitoring of both anthropic and natural radionuclides, as well as their correlation with the ecosystem and the population. Terrestrial sources, which mainly include the primary radionuclides of the 238 U, 232 Th, and 40 K series, contribute to a higher effective dose received by humanity, with 84% from terrestrial radionuclides and another 16% derived from cosmogenic nuclides. Areas with high levels of natural radiation, above the acceptable limits, are of great relevance for the development of dosimetry studies, whose core aims include the preservation of the environment and the control of the population's exposure to radiation. The town of Sao Jose de Espinharas, Paraiba, Brazil, has a uranium oxide mine with an average grade of 1,200 mg/kg. In the present study, non-destructive, in situ assays were performed along the entire radiometrically anomalous area. The results obtained in terms of effective doses varied from 3.79 to 93.80 mSv.y -1 , with an average of 19.47 mSv.y -1 thus leading to the conclusion that all of the monitored points presented environmental doses of above the reference value of 2.4 mSv.y -1 , suggesting that both qualitative and quantitative analyses concerning the environmental matrixes in question need to be performed. (author)

  20. Status of neutron dosimetry cross sections

    International Nuclear Information System (INIS)

    Griffin, P.J.; Kelly, J.G.

    1992-01-01

    Several new cross section libraries, such as ENDF/B-VI(release 2), IRDF-90,JEF-2.2, and JENDL-3 Dosimetry, have recently been made available to the dosimetry community. the Sandia National Laboratories (SNL) Radiation Metrology Laboratory (RML) has worked with these libraries since pre-release versions were available. this paper summarizes the results of the intercomparison and testing of dosimetry cross sections. As a result of this analysis, a compendium of the best dosimetry cross sections was assembled from the available libraries for use within the SNL RML. this library, referred to as the SNLRML Library, contains 66 general dosimetry sensors and 3 special dosimeters unique to the RML sensor inventory. The SNLRML cross sections have been put into a format compatible with commonly used spectrum determination codes

  1. Tooth enamel electron spin resonance dosimetry of people living in the area with lime tobacco custom

    International Nuclear Information System (INIS)

    Jiao Ling; Zhang Wenyi; Ding Yanqiu

    2010-01-01

    Objective: To study the effect of the custom of long term chewing lime tobacco on human tooth enamel electron spin resonance (ESR) dosimetry. Methods: A total of 20 enamel samples from lingual parts of adults teeth collected in Bombay, India were obtained by mechanical method. Some enamel samples from Japanese adults were extracted and 10 mixed samples were prepared. Enamel samples were exposed to different doses of 60 Co γ-rays several times, and ESR spectra were measured after exposure. Results: ESR background signals of 9 Bombay samples were found 1.5-3.3 times higher than those of Japanese mixed samples. The γ-ray dose responses of dosimetric signal with higher background level were a little lower, and the average sensitivity was (0.42±0.03) mGy, which was close to that of Japanese mixed samples. Conclusions: The average level of background signals of Bombay samples was much higher than that of other non-chewing tobacco area, which was possibly caused by tobacco area, which was possibly caused by tobacco lime, the main component in chewing tobacco productions, and it would help to explore its special influences on ESR, and improve dose reconstruction in accuracy. (authors)

  2. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  3. Revisiting photodynamic therapy dosimetry: reductionist & surrogate approaches to facilitate clinical success

    Science.gov (United States)

    Pogue, Brian W.; Elliott, Jonathan T.; Kanick, Stephen C.; Davis, Scott C.; Samkoe, Kimberley S.; Maytin, Edward V.; Pereira, Stephen P.; Hasan, Tayyaba

    2016-04-01

    Photodynamic therapy (PDT) can be a highly complex treatment, with many parameters influencing treatment efficacy. The extent to which dosimetry is used to monitor and standardize treatment delivery varies widely, ranging from measurement of a single surrogate marker to comprehensive approaches that aim to measure or estimate as many relevant parameters as possible. Today, most clinical PDT treatments are still administered with little more than application of a prescribed drug dose and timed light delivery, and thus the role of patient-specific dosimetry has not reached widespread clinical adoption. This disconnect is at least partly due to the inherent conflict between the need to measure and understand multiple parameters in vivo in order to optimize treatment, and the need for expedience in the clinic and in the regulatory and commercialization process. Thus, a methodical approach to selecting primary dosimetry metrics is required at each stage of translation of a treatment procedure, moving from complex measurements to understand PDT mechanisms in pre-clinical and early phase I trials, towards the identification and application of essential dose-limiting and/or surrogate measurements in phase II/III trials. If successful, identifying the essential and/or reliable surrogate dosimetry measurements should help facilitate increased adoption of clinical PDT. In this paper, examples of essential dosimetry points and surrogate dosimetry tools that may be implemented in phase II/III trials are discussed. For example, the treatment efficacy as limited by light penetration in interstitial PDT may be predicted by the amount of contrast uptake in CT, and so this could be utilized as a surrogate dosimetry measurement to prescribe light doses based upon pre-treatment contrast. Success of clinical ALA-based skin lesion treatment is predicted almost uniquely by the explicit or implicit measurements of photosensitizer and photobleaching, yet the individualization of treatment

  4. Evolution of the Regular monitoring of workers using ionizing radiations in medical field in France

    International Nuclear Information System (INIS)

    Biau, A.; Valero, M.; Dubuquoy, E.; Crescini, D.

    2002-01-01

    Among the 260000 workers surveyed by individual monitoring dosimetry in France, about 140000 work in medical field, in Radiodiagnostic. Radiotherapy or Nuclear Medicine. For the twenty last years the global exposure of these workers has decreased continuously like the number of doses over the regular limits of 50 millisieverts per year or even 20 millisieverts which will be included in the new regulations according to the European Directive 96/29 of 13 may 1996. To reinforce this evolution to lower exposures (ALARA) the french regulations have been completed in 1998 and 1999. These new regular prescriptions consist essentially in. - possibility of using another system of passive dosimetry than firm dosimeter (TLD, OSL, RPL...) - obligation of active dosimeter (real time reading) associated with the passive dosimeter for the workers affected in controlled area. - gathering of all the dosimetric results on a data base called SISERI accessible by computer only to the health physicians and the competent person specially authorized. This work is showing from statistical data on the levels of exposure in medical field: - which are the working conditions for which the two system of dosimetry are really necessary - how to delimit the controlled area on realistic basic rather than theoretical assumptions - how the data base SISERI is actually functioning and how it will evaluate from now to 2003. Finally, we propose a schedule to define the different forms of survey for internal and external risks of exposure and to select the best type of monitoring according to the working conditions. (Author)

  5. The Latin American Biological Dosimetry Network (LBDNet)

    International Nuclear Information System (INIS)

    Garcia, O.; Lamadrid, A.I.; Gonzalez, J.E.; Romero, I.; Mandina, T.; Di Giorgio, M.; Radl, A.; Taja, M.R.; Sapienza, C.E.; Deminge, M.M.; Fernandez Rearte, J.; Stuck Oliveira, M.; Valdivia, P.; Guerrero-Carbajal, C.; Arceo Maldonado, C.; Cortina Ramirez, G.E.; Espinoza, M.; Martinez-Lopez, W.; Di Tomasso, M.

    2016-01-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. (authors)

  6. In vivo dosimetry study of semi-conductors EPD-20 in total body irradiation technique; Etude de la dosimetrie in vivo par semi-conducteurs EPD-20 dans les conditions de l'irradiation corporelle totale

    Energy Technology Data Exchange (ETDEWEB)

    Besbes, M.; Kochbati, L.; Ben Abdennabi, A.; Abdessaied, S.; Salem, L.; Frikha, H.; Nasr Ben Ammar, C.; Hentati, D.; Gargouri, W.; Messai, T.; Benna, F.; Maalej, M. [Institut Salah-Azaiz, Service de radiotherapie oncologique, Tunis (Tunisia); Mahjoubi, H. [Institut superieur des technologies medicales de Tunis, Dept. de biophysique, Tunis (Tunisia); Farhat, L. [CHU Habib-Bourguiba, Service de radiotherapie oncologique, Sfax (Tunisia)

    2010-01-15

    Purpose: The objective of this work was the study of in vivo dosimetry performed in a series of 54 patients receiving total body irradiation (T.B.I.) at the Salah-Azaiz Institute of Tunis since 2004. In vivo dosimetry measurements were compared to analytically calculated doses from monitor units delivered. Patients and method: The irradiation was conducted by a linear accelerator (Clinac 1800, Varian, Palo Alto, USA) using nominal X-rays energies of 6 MV and 18 MV, depending on the thickness of the patient at the abdomen. The dose was measured by semi-conductors p-type E.P.D.-20. These diodes were calibrated in advance with an ionization chamber 'P.T.W. Farmer' type of 0.6 cm{sup 3} and were placed on the surface of plexiglas phantom in the same T.B.I. conditions. A study of dosimetric characteristics of semi-conductors E.P.D.-20 was carried out as a function of beam direction and temperature. Afterwards, we conducted a comparative analysis of doses measured using these detectors during irradiation to those calculated retrospectively from monitor units delivered to each patient conditioned by T.B.I.. Results: Experience showed that semi-conductors are sensitive to the angle of beam radiation (0-90 degrees) and the temperature (22-40 Celsius degrees). The maximum variation is respectively 5 and 7%, but in our irradiation conditions these correction factors are less than 1%. The analysis of the results of the in vivo dosimetry had shown that the ratio of the average measured doses and analytically calculated doses at the abdomen, mediastinum, right lung and head are 1.005, 1.007, 1.0135 and 1.008 with a standard deviation 'type A' respectively of 3.04, 2.37, 7.09 et 4.15%. Conclusion: In vivo dosimetry by semi-conductors is in perfect agreement with dosimetry by calculation. However, in vivo dosimetry using semiconductors is the only technique that can reflect the dose actually received instantly by the patient during T.B.I. given the many factors

  7. Internal dosimetry, past and future

    International Nuclear Information System (INIS)

    Johnson, J.R.

    1989-03-01

    This paper is a review of the progress in the dosimetry of internally deposited radionuclides (internal dosimetry) since World War II. Previous to that, only naturally occurring radionuclides were available and only a limited number of studies of biokinetics and dosimetry were done. The main radionuclides studied were 226 Ra, 228 Ra, and 224 Ra but natural uranium was also studied mainly because of its toxic effect as a heavy metal, and not because it was radioactive. The effects of 226 Ra in bone, mainly from the radium dial painters, also formed the only bases for the radiotoxicity of radionuclides in bone for many years, and it is still, along with 224 Ra, the main source of information on the effects of alpha emitters in bone. The publications of the International Commission on Radiological Protection that have an impact on internal dosimetry are used as mileposts for this review. These series of publications, more than any other, represent a broad consensus of opinion within the radiation protection community at the time of their publication, and have formed the bases for radiation protection practice throughout the world. This review is not meant to be exhaustive; it is meant to be a personnel view of the evolution of internal dosimetry, and to present the author's opinion of what the future directions in internal dosimetry will be. 39 refs., 2 tabs

  8. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Mattea, F. [Universidad Nacional de Cordoba, Facultad de Ciencias Quimicas, Departamento de Quimica Organica, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: josevedelago@gmail.com [Instituto de Fisica E. Gaviola, Oficina 102 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  9. Development a high-resolution radiation dosimetry system based on Fricke solutions

    International Nuclear Information System (INIS)

    Vedelago, J.; Mattea, F.; Valente, M.

    2014-08-01

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  10. Off-site environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1985

    International Nuclear Information System (INIS)

    Grossman, R.F.; Black, S.C.; Dye, R.E.; Smith, D.D.; Thome, D.J.; Mullen, A.A.

    1986-04-01

    The EMSL-LV operates an Off-Site Radiological Safety Program around the NTS and other sites as requested by the Department of Energy (DOE) under an Interagency Agreement between DOE and EPA. This report, prepared in accordance with DOE guidelines (DOE85a), covers the program activities for calendar year 1985. It contains descriptions of pertinent features of the NTS and its environs, summaries of the EMSL-LV dosimetry and sampling methods, analytical procedures, quality assurance, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation

  11. A method for automating calibration and records management for instrumentation and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr. [Atlan-Tech, Inc., Roswell, GA (United States)

    1993-12-31

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation.

  12. A method for automating calibration and records management for instrumentation and dosimetry

    International Nuclear Information System (INIS)

    O'Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr.

    1993-01-01

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation

  13. Advantages and disadvantages of luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olko, Pawel, E-mail: Pawel.Olko@ifj.edu.p [Institute of Nuclear Physics Polish Academy of Science (IFJ PAN), Krakow (Poland)

    2010-03-15

    Owing to their excellent dosimetric properties, luminescence detectors of ionizing radiation are now extensively applied in individual dosimetry services. The most frequently used personal dosemeters are based on Optically Stimulated Luminescence (OSL), radiophotoluminescence (RPL) or thermoluminescence (TL). Luminescence detectors have also found several applications in clinical dosimetry, especially around new radiation modalities in radiotherapy, such as Intensity Modulated Radiotherapy (IMRT) or ion beam radiotherapy. Requirements of luminescence detectors applied in individual and clinical dosimetry and some recent developments in luminescence of detectors and techniques leading to significant improvements of the functionality and accuracy of dosimetry systems are reviewed and discussed.

  14. Study of the personal dosimetry service by thermoluminiscence

    International Nuclear Information System (INIS)

    Penaherrera, Patricio; Buitron, Susana; Prado, Elizabeth; Ceron Fabiola

    1992-01-01

    This paper is concerned with the personal dosimetry service given by the Ecuadorian Atomic Energy Commission to radiation exposed workers in Ecuador. The study has taken in consideration the number of professionals working in Ecuador by province and by area of work, and also the radiation doses received by them during the period 1987-1990

  15. Thermoluminescence dosimetry and its applications in medicine. Part 2: history and applications

    International Nuclear Information System (INIS)

    Kron, T.

    1995-01-01

    Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of μ Gy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. TLD is considered to be a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review. 198 refs., 4 tabs., 2 figs

  16. Clinical proton dosimetry. Part 1: Beam production, beam delivery and measurement of absorbed dose

    International Nuclear Information System (INIS)

    1998-01-01

    The development of accurate and uniform standards for radiation treatment dosimetry has been a continuing effort since the earliest days of radiotherapy. This ICRU Report is intended to promote uniformity of standards that will provide a basis for world-wide comparison of clinical results and allow the development of meaningful clinical trials. This Report describes current practice in proton therapy and recommends standards for the dosimetry of proton treatments. Established proton treatment facilities might use this Report as a source of information for the maintenance of accurate standards. New facilities may build their procedures from recommendations found in this Report and planners of new facilities may examine alternatives within current practice for the production and monitoring of treatment beams. This Report includes a description of the interaction of protons with matter, various methods of beam production, the characteristics of proton beams in clinical use, current methods for beam monitoring and specific recommendations for dose calibration

  17. Bench mark spectra for high-energy neutron dosimetry

    International Nuclear Information System (INIS)

    Dierckx, R.

    1986-01-01

    To monitor radiation damage experiments, activation detectors are commonly used. The precision of the results obtained by the multiple foil analysis is largely increased by the intercalibration in bench-mark spectra. This technique is already used in dosimetry measurements for fission reactors. To produce neutron spectra similar to fusion reactor and high-energy high-intensity neutron sources (d-Li or spallation), accelerators can be used. Some possible solutions as p-Be and d-D 2 O neutron sources, useful as bench-mark spectra are described. (author)

  18. The MCART radiation physics core: the quest for radiation dosimetry standardization.

    Science.gov (United States)

    Kazi, Abdul M; MacVittie, Thomas J; Lasio, Giovanni; Lu, Wei; Prado, Karl L

    2014-01-01

    Dose-related radiobiological research results can only be compared meaningfully when radiation dosimetry is standardized. To this purpose, the National Institute of Allergy and Infectious Diseases (NIAID)-sponsored Medical Countermeasures Against Radiological Threats (MCART) consortium recently created a Radiation Physics Core (RPC) as an entity to assume responsibility of standardizing radiation dosimetry practices among its member laboratories. The animal research activities in these laboratories use a variety of ionizing photon beams from several irradiators such as 250-320 kVp x-ray generators, Cs irradiators, Co teletherapy machines, and medical linear accelerators (LINACs). In addition to this variety of sources, these centers use a range of irradiation techniques and make use of different dose calculation schemes to conduct their experiments. An extremely important objective in these research activities is to obtain a Dose Response Relationship (DRR) appropriate to their respective organ-specific models of acute and delayed radiation effects. A clear and unambiguous definition of the DRR is essential for the development of medical countermeasures. It is imperative that these DRRs are transparent between centers. The MCART RPC has initiated the establishment of standard dosimetry practices among member centers and is introducing a Remote Dosimetry Monitoring Service (RDMS) to ascertain ongoing quality assurance. This paper will describe the initial activities of the MCART RPC toward implementing these standardization goals. It is appropriate to report a summary of initial activities with the intent of reporting the full implementation at a later date.

  19. Workshop on internal dosimetry in the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gómez Parada, I.; Gossio, S.; Puerta Yepes, N.; Saavedra, A.D.; Segato, A.D.

    2011-01-01

    Dose assessment in case of internal exposure involves the estimation of committed effective dose based on the interpretation of bioassay measurement, and the assumptions of hypotheses on the characteristics of the radioactive material and the time pattern and the pathway of intake. In the case of workers exposed in nuclear fuel facilities, the normal uranium excretion from the diet is an additional difficulty in the process of assessing internal exposure. The aim of this paper is to present the main topics discussion and the conclusions of the workshop, held in the frame of the missions of the Autoridad Regulatoria Nuclear. All the personnel involved in the control of internal exposure in nuclear fuel cycle was invited to participate in the workshop to discuss about individual monitoring criteria and the available tools for assessing committed effective dose in the workers of their facilities. The lectures were presented jointly by the Nuclear Fuel Cycle Facilities Control and the Dosimetric and Radiobiological Assessment departments. It was hold at the Ezeiza Atomic Center from 23th to 24th November 2010 based on the Advanced Course on Internal Dosimetry organized on 2009 and focusing specific uranium compound internal dosimetry. A representative of each facility was invited to present the monitoring program implemented for controlling the internal exposure. It was an opportunity to discuss criteria and to share experiences on this field in the frame of the ICRP, HPA and ISO publications. The different monitoring program criteria could be analyzed and so contributing to the improvement of radiological protection. Finally, it was agreed to hold periodical meetings to assure the update on uranium measurement techniques and the handling of monitoring data for committed effective dose assessment. (authors) [es

  20. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Hoefert, M.; Nielsen, M.

    1996-01-01

    In 1995 both the Individual Dosimetry and Calibration Sections worked under the condition of a status quo and concentrated fully on the routine part of their work. Nevertheless, the machine for printing the bar code which will be glued onto the film holder and hence identify the people when entering into high radiation areas was put into operation and most of the holders were equipped with the new identification. As far as the Calibration Section is concerned the project of the new source control system that is realized by the Technical Support Section was somewhat accelerated

  1. A preliminary study on thermoluminescence of AMOLED glass from mobile phones for retrospective dosimetry

    International Nuclear Information System (INIS)

    Kim, Hyoungtaek; Lee, Jungil; Chang, Insu; Lee, Seung Kyu; Kim, Min Chae; Park, Sang Won; Kim, Jang-Lyul; Kim, Bong-Hwan; Yu, Hyungjoon; Kim, Ah-reum

    2017-01-01

    Since mobile phones are always carried by individuals, the retrospective dosimetry using thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristics of elements in mobile phone is intensively developing nowadays due to its advantages over conventional biological dosimetry techniques. Using a TL and OSL method on resistors and inductors in a mobile phone, a low background dose (zero dose) about tens of mGy is acquired in previous study. Radiation workers have to wear a dosimeter to assess individual exposure during their works. This monitoring system facilitate a fast medical treatment for highly exposed workers in case of a radiation accident. In the event of large-scale radiation accidents, where most of the subjects are ordinary people, it is difficult to evaluate the individual dose due to the absence of dosimeters. A technique for dose evaluation using a radiation dependency of various materials in the absence of a dosimeter is called retrospective dosimetry.

  2. Nevada Test Site, 2006 Waste Management Monitoring Report, Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    David B. Hudson

    2007-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and concentrations of americium and plutonium are only slightly above detection limits at the Area 3 RWMS. Measurements at the Area 5 RWMS show that radon flux from waste covers is no higher than natural radon flux from undisturbed soil in Area 5. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. Precipitation during 2006 totaled 98.6 millimeters (mm) (3.9 inches [in.]) at the Area 3 RWMS and 80.7 mm (3.2 in.) at the Area 5 RWMS. Soil-gas tritium monitoring continues to show slow subsurface migration consistent with previous results. Moisture from precipitation at Area 5 remains at the bottom of the bare-soil weighing lysimeter, but this same moisture has been removed from the vegetated weighing lysimeter by evapotranspiration. Vadose zone data from the operational waste pit covers show that evaporation continues to slowly remove soil moisture that came from the heavy precipitation in the fall of 2004 and the spring of

  3. Analysis of Land Subsidence Monitoring in Mining Area with Time-Series Insar Technology

    Science.gov (United States)

    Sun, N.; Wang, Y. J.

    2018-04-01

    Time-series InSAR technology has become a popular land subsidence monitoring method in recent years, because of its advantages such as high accuracy, wide area, low expenditure, intensive monitoring points and free from accessibility restrictions. In this paper, we applied two kinds of satellite data, ALOS PALSAR and RADARSAT-2, to get the subsidence monitoring results of the study area in two time periods by time-series InSAR technology. By analyzing the deformation range, rate and amount, the time-series analysis of land subsidence in mining area was realized. The results show that InSAR technology could be used to monitor land subsidence in large area and meet the demand of subsidence monitoring in mining area.

  4. Ionizing radiations dosimetry: new results in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.

    1989-01-01

    Industrial irradiation for food preservation, medical sterilization and plastic processing is in great expansion and an accurate dosimetry in the megagray range is required. It is also required for safety purposes around nuclear reactors or waste storage sites. The study of photon-matter interaction leads us to consider high-dose dosimeters among the solids in which radiolysis occurs. Organic conductors are indeed good candidates for high-dose dosimetry. These materials show original properties due to the great anisotropy of their electronic system. Radiation effects, especially on the resistivity and on the (E.S.R.) Electron Spin Resonance linewidth, are very important. We show that a simple resistance measurement allows an accurate monitoring of the absorbed dose, in the range 0.01 - 50 MGy, for X-rays, gamma-rays and electron irradiations. The E.S.R. linewidth measurements permits the use of small dosimeters between 1 and 100 MGy. Finally, some organic conductors are proposed as high-temperature dosimeters for irradiation performed up to 120 0 C. The irradiated pure silica contains a large variety of defects. Only the E' center seems helpful for dosimetry purposes, and its electron spin resonance (E.S.R.) signal is simply related to the absorbed dose in the range 0.1 - 3 MGy or even, 0.5 kGy - 5 MGy [fr

  5. Report on a workshop on the application of thermoluminescence dosimetry to large scale individual monitoring, Ispra, 11-13 September 1985

    International Nuclear Information System (INIS)

    Barthe, J.R.; Christensen, P.; Driscoll, C.M.H.; Marshall, T.O.; Harvey, J.R.; Julius, H.W.; Marshall, M.; Oberhoffer, M.

    1987-01-01

    The workshop was held for the benefit of those actually involved in the operation of large scale automatic thermoluminescence dosimetry systems. It was organised around three overall themes subdivided into 13 subject headings: External constraints: User requirements, Quantities and Units, Legal requirements, Testing, Intercomparisons; Dosimetry systems: Materials, Dosemeter design, Reading systems, Annealing procedures, Rogue readings; Management: Distribution and organisation, Reporting and record keeping, Financial aspects. (author)

  6. Personnel Dosimetry for Radiation Accidents. Proceedings of a Symposium on Personnel Dosimetry for Accidental High-Level Exposure to External and Internal Radiation

    International Nuclear Information System (INIS)

    1965-01-01

    Accidents involving the exposure of persons to high levels of radiation have been few in number and meticulous precautions are taken in an effort to maintain this good record. When, however, such an accident does occur, a timely estimate of the dose received can be of considerable help to the physician in deciding whether a particular person requires medical treatment, and in selecting the most appropriate treatment. Individual dosimetry provides the physical basis for relating the observed effects to those in other accident cases, to other human data, and to data from animal experiments, thus providing an important aid to rational treatment and to the accumulation of a meaningful body of knowledge on the subject. It is most important therefore that, where there is a possibility of receiving high-level exposure, methods of personnel dosimetry should be available that would provide the dosimetric information most useful to the physician. Provision of good personnel dosimetry for accidental high-level exposure is in many cases an essential part of emergency planning because the information provided may influence emergency and rescue operations, and can lead to improved accident preparedness. Accordingly, the International Atomic Energy Agency and the World Health Organization jointly organized the Symposium on Personnel Dosimetry for Accidental High-Level Exposure to External and Internal Radiation for the discussion of such methods and for a critical review of the procedures adopted in some of the radiation accidents that have already occurred. The meeting was attended by 179 participants from 34 countries and from five other international organizations. The papers presented and the ensuing discussions are published in these Proceedings. It is hoped that the Proceedings will be of help to those concerned with the organization and development of wide-range personnel monitoring systems, and with the interpretation of the results provided

  7. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  8. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  9. SU-C-BRD-07: The Radiological Physics Center (RPC): 45 Years of Improving Radiotherapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Followill, D; Lowenstein, J; Molineu, A; Alvarez, P; Summers, P; Kry, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    Purpose: The RPC, established in 1968 has contributed to the development, conduct, and QA of NCI funded multi-institutional cooperative group clinical trials and institutions, primarily in the USA/Canada and 242 other countries, participating in trials. Methods: The RPC QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program included: 1) remote TLD/OSLD audit of machine output, 2) on-site dosimetry review visits, 3) credentialing for advanced technologies, and 4) review of patient treatment records. The RPC presented and published their findings to the radiation oncology community. Results: The number of institutions monitored by the RPC increased from around 1200 in the late 90s, to ∼2000 in 2013. There were over 4000 megavoltage therapy machines and ∼28,000 therapy beams in the 1991 institutions monitored by the RPC by the end of 2013. Within the 14,000 photon, electron and proton beam outputs remotely monitored with TLD/OSLD annually, between 10-20% of the institutions have one or more beams outside the RPC 5% criterion. Dosimetry site visits to photon and proton centers continue to result in 2-4 recommendations affecting key dosimetry parameters that impact patient treatment times. One in four patient treatment records reviewed by the RPC have their dose data corrected by >5% before trial groups use them for outcomes analysis. Twelve of fourteen clinically active proton centers are approved to participate in NCI funded clinical trials. The RPC published 222 peer reviewed articles since 1972. Conclusion: Findings from the RPC suggest that human errors continue to play a role in radiotherapy discrepancies and without the RPC independent QA program, the number of undetected errors and time elapsed before their discovery would have been greater. Work supported by

  10. SU-F-T-272: Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Darko, J; Osei, E [Grand River Cancer Centre @ Grand River Hospital, Kitchener, ON (Canada); University of Waterloo, Waterloo, ON (Canada); Kiciak, A [University of Waterloo, Waterloo, ON (Canada); Badu, S; Grigorov, G; Fleck, A [Grand River Cancer Centre @ Grand River Hospital, Kitchener, ON (Canada)

    2016-06-15

    Purpose: To evaluate the effectiveness of using the Portal Dosimetry (PD) method for patient specific quality assurance of prostate VMAT plans. Methods: As per institutional protocol all VMAT plans were measured using the Varian Portal Dosimetry (PD) method. A gamma evaluation criterion of 3%-3mm with a minimum area gamma pass rate (gamma <1) of 95% is used clinically for all plans. We retrospectively evaluated the portal dosimetry results for 170 prostate patients treated with VMAT technique. Three sets of criterions were adopted for re-evaluating the measurements; 3%-3mm, 2%-2mm and 1%-1mm. For all criterions two areas, Field+1cm and MLC-CIAO were analysed.To ascertain the effectiveness of the portal dosimetry technique in determining the delivery accuracy of prostate VMAT plans, 10 patients previously measured with portal dosimetry, were randomly selected and their measurements repeated using the ArcCHECK method. The same criterion used in the analysis of PD was used for the ArcCHECK measurements. Results: All patient plans reviewed met the institutional criteria for Area Gamma pass rate. Overall, the gamma pass rate (gamma <1) decreases for 3%-3mm, 2%-2mm and 1%-1mm criterion. For each criterion the pass rate was significantly reduced when the MLC-CIAO was used instead of FIELD+1cm. There was noticeable change in sensitivity for MLC-CIAO with 2%-2mm criteria and much more significant reduction at 1%-1mm. Comparable results were obtained for the ArcCHECK measurements. Although differences were observed between the clockwise verses the counter clockwise plans in both the PD and ArcCHECK measurements, this was not deemed to be statistically significant. Conclusion: This work demonstrates that Portal Dosimetry technique can be effectively used for quality assurance of VMAT plans. Results obtained show similar sensitivity compared to ArcCheck. To reveal certain delivery inaccuracies, the use of a combination of criterions may provide an effective way in improving

  11. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Bourel, V.; Schmidt, L.; Di Risio, C.

    2014-08-01

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  12. Dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  13. Dosimetry of hands and human factor

    International Nuclear Information System (INIS)

    Harr, R.

    2008-12-01

    The human factor in facilities where open radioactive sources are managed it can be controlled through the use of the ring dosimetry, however, that these devices only provide qualitative information that is not extrapolated to legislative limits. lt is present the case analysis of hands dosimetry of female person with responsibility for professional standards and a very high profile with ratings that allow her to have a high level of knowledge of the basic standards, and because with an attitude and a culture rooted of radiation protection, among other qualities. Their records reveal a trend in which monthly doses are below the 7 mSv, and only occasionally are between 7 and 12 mSv per month and hand. The other case correspond to a technician, trained in radiological techniques, also with a high profile, with two courses for occupationally exposed personnel more than 10 annual retraining, and work experience of over 10 years as occupationally exposed personnel, in which knowledge of standards and because of the entrenched culture of radiation protection and their interest degree in the care of their exposure is still in a phase half, in this case also shows a trend in the monthly dose where found registers between 7 and 11 mSv per month and hand. The third case is of a second technician with less experience and most basic knowledge, his dose register not show a real trend, sometimes be found reads of irregular values as if the dosimeter is not used and some other times as if misused by exposing to purpose (was observed at least one reading above the monthly 30 mSv). By way of conclusion, it is noted that the hands dosimetry is a useful tool to monitor transactions through the data compilation susceptible to analysis with variations which can be placed in the context of the human factor. (Author)

  14. Uranium Dispersion and Dosimetry (UDAD) Code

    International Nuclear Information System (INIS)

    Momeni, M.H.; Yuan, Y.; Zielen, A.J.

    1979-05-01

    The Uranium Dispersion and Dosimetry (UDAD) Code provides estimates of potential radiation exposure to individuals and to the general population in the vicinity of a uranium processing facility. The UDAD Code incorporates the radiation dose from the airborne release of radioactive materials, and includes dosimetry of inhalation, ingestion, and external exposures. The removal of raioactive particles from a contaminated area by wind action is estimated, atmospheric concentrations of radioactivity from specific sources are calculated, and source depletion as a result of deposition, fallout, and ingrowth of radon daughters are included in a sector-averaged Gaussian plume dispersion model. The average air concentration at any given receptor location is assumed to be constant during each annual release period, but to increase from year to year because of resuspension. Surface contamination and deposition velocity are estimated. Calculation of the inhalation dose and dose rate to an individual is based on the ICRP Task Group Lung Model. Estimates of the dose to the bronchial epithelium of the lung from inhalation of radon and its short-lived daughters are calculated based on a dose conversion factor from the BEIR report. External radiation exposure includes radiation from airborne radionuclides and exposure to radiation from contaminated ground. Terrestrial food pathways include vegetation, meat, milk, poultry, and eggs. Internal dosimetry is based on ICRP recommendations. In addition, individual dose commitments, population dose commitments, and environmental dose commitments are computed. This code also may be applied to dispersion of any other pollutant

  15. H-Area Seepage Basins groundwater monitoring report

    International Nuclear Information System (INIS)

    1992-09-01

    During second quarter 1992, tritium, nitrate, nonvolatile beta, total alpha-emitting radium (radium-224 and radium-226), gross alpha, mercury, lead, tetrachloroethylene, arsenic, and cadmium exceeded the US Environmental Protection Agency Primary Drinking Water Standards (PDWS) in groundwater samples from monitoring wells at the H-Area Seepage Basins (HASB) at the Savannah River Plant. This report gives the results of the analyses of groundwater from the H-Area Seepage Basin

  16. A Review of the New European Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Alves, J.G.; Ambrosi, P.; Bartlett, D.T.; Currivan, L.; Fantuzzi, E.; Kamenopoulou, V.

    2013-01-01

    This paper reviews the revised Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation as issued by the European Commission as Radiation Protection 160. These recommendations are aimed at all stakeholders in radiation protection dosimetry with an emphasis in the responsible technical staff of approved dosimetry services. This paper briefly touches each Chapter and ends with a more in depth section on the uncertainty evaluation of dose measurements. -- Highlights: ► Recommendations on all aspects of running an approved dosimetry service. ► Radiation protection framework. ► Metrology of personal dosimeters. ► QC and QA of individual monitoring

  17. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  18. An application of artificial neural intelligence for personal dose assessment using a multi-area OSL dosimetry system

    International Nuclear Information System (INIS)

    Lee, S.-Y.Sang-Yoon.; Kim, B.-H.Bong-Hwan; Lee, K.J.Kun Jai

    2001-01-01

    Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on α-Al 2 O 3 : C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using α-Al 2 O 3 : C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of an X- and γ-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of α-Al 2 O 3 : C for arbitrarily mixed photon fields which range from 20 to 662 keV

  19. Measurement of outdoor radioactivities of radon and thoron by the passive radon-thoron monitor of cup type with cellulose nitrate film

    International Nuclear Information System (INIS)

    Ogawa, Y.; Kimura, Y.; Iida, T.; Yamasaki, K.; Tsujimoto, T.

    1993-01-01

    In order to get information as to effective dose of radon and thoron for the public, we investigated the dosimetry of the average outdoor concentrations of radon and thoron by the cup type radon/thoron monitor using cellulose nitrate film. To overcome the disadvantages of cup monitors which are the relatively low sensitivity and the relatively high detection limit, the present dosimetry is based on the usage of several pairs of cup monitors and the statistical treatments (significant test). Because the detection limit could be lowered using the present dosimetry, we could measure the outdoor concentration levels more precisely. (1 tab.)

  20. The Latin American Biological Dosimetry Network (LBDNet).

    Science.gov (United States)

    García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M

    2016-09-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Research and innovation in radiation dosimetry

    International Nuclear Information System (INIS)

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  2. Dosimetry control for radiation processing - basic requirements and standards

    International Nuclear Information System (INIS)

    Ivanova, M.; Tsrunchev, Ts.

    2004-01-01

    A brief review of the basic international codes and standards for dosimetry control for radiation processing (high doses dosimetry), setting up a dosimetry control for radiation processing and metrology control of the dosimetry system is made. The present state of dosimetry control for food processing and the Bulgarian long experience in food irradiation (three irradiation facilities are operational at these moment) are presented. The absence of neither national standard for high doses nor accredited laboratory for calibration and audit of radiation processing dosimetry systems is also discussed

  3. Dosimetry in dentistry.

    Science.gov (United States)

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  4. Patient dosimetry workshop - Scanner in clinical practice: how to optimize one's protocols (acquisition, interpretation, dosimetry)? - Radiation protection in medical environment

    International Nuclear Information System (INIS)

    Valero, M.; Pilleul, F.; Favre, F.; Tack, D.; Etard, C.; Aubert, B.; Roch, P.; Sinno-Tellier, S.; Gevenois, P.A.; Marelle, P.; Noel, A.; Coquel, P.; Museux, E.; Lair, F.; Francois, A.; Lemaire, P.; Delgoffe, C.; Puech, J.L.; Haller Montejo, M.; Rousselle, I.; Noel, A.; Pierrat, N.; Lasalle, S.; Brisse, H.; Guerson, T.; Mertz, L.; Mertz, M.; Wasylczenko, T.; Bietry, J.; Notter, S.; Jahnen, A.; Back, C.; Kohler, S.; Harpes, N.

    2010-01-01

    A selection of eleven brief communications given at the 2010 French days of radiology are compiled here and deal with: 1 - patient's dosimetry in classical radiology (Valero, M.); 2 - Oncology: how to optimize monitoring (dosimetry, new response criteria)? (Pilleul, F.; Favre, F.); 3 - Thorax: how to optimize lecture (MPR - Multi-Planar Reformat, MIP - Maximum Intensity Projection, MinIP - minimum intensity projection) and dosimetry? (Braine-L'Alleud); 4 - Medical exposure of the French population to diagnostic techniques in 2007 (Etard, C.; Aubert, B.; Sinno-Tellier, S.); 5 - Doses delivered to patients in radio-diagnostics: status of a national inquiry in the public sector (Etard, C.; Sinno-Tellier, S.; Aubert, B.); 6 - External help for the dose per section optimization in tomodensitometry (Tack, D.; Jahnen, A.; Back, C.; Kohler, S.; Harpes, N.; Gevenois, P.A.); 7 - Diagnostic reference levels (DRL) in radiology and scanography: status and evolution (Roch, P.; Aubert, B.); 8 - What conclusions can be drawn from the analysis of the DRLs in conventional radiology addressed to the CEPPIM (College for the evaluation of professional practices in medical imaging) (Marelle, P.; Coquel, P.; Museux, E.; Lair, F.; Francois, A.; Lemaire, P.; Delgoffe, C.; Puech, J.L.; Haller Montejo, M.); 9 - DRL analysis in scanography, an optimization tool? (Rousselle, I.; Noel, A.); 10 - Iterative reconstruction in scanography: potential dosimetric benefit and impact on image quality (Pierrat, N.; Lasalle, S.; Guerson, T.; Brisse, H.); 11 - Development of a patient's dose optimisation aided system in medical imaging (Mertz, L.; Mertz, M.; Wasylczenko, T.; Bietry, J.; Notter, S.)

  5. Guide for selection of dosimetry system for electron processing

    International Nuclear Information System (INIS)

    Mehta, K.

    1988-01-01

    Correct applications of radiation processing depend on accurate measurements of absorbed radiation dose. Radiation dosimetry plays several important roles in radiation processing. In particular, there are three stages for any radiation process during which dosimetry is a key to success: basic laboratory research, commissioning of the process and quality control. Radiation dosimeters may be divided into various classes depending upon their areas of applications and their relative quality: primary standard dosimeter, reference standard dosimeter, transfer standard dosimeter and routine in-house dosimeter. Several commercially available dosimeters are described under each class, and their advantages and limitations are discussed. Finally, recommendations are made as to which dosimeter is most suitable for each of the three stages of electron-beam processing. 124 refs

  6. Revisiting photodynamic therapy dosimetry: reductionist and surrogate approaches to facilitate clinical success

    International Nuclear Information System (INIS)

    Pogue, Brian W; Elliott, Jonathan T; Kanick, Stephen C; Davis, Scott C; Samkoe, Kimberley S; Maytin, Edward V; Pereira, Stephen P; Hasan, Tayyaba

    2016-01-01

    Photodynamic therapy (PDT) can be a highly complex treatment, with many parameters influencing treatment efficacy. The extent to which dosimetry is used to monitor and standardize treatment delivery varies widely, ranging from measurement of a single surrogate marker to comprehensive approaches that aim to measure or estimate as many relevant parameters as possible. Today, most clinical PDT treatments are still administered with little more than application of a prescribed drug dose and timed light delivery, and thus the role of patient-specific dosimetry has not reached widespread clinical adoption. This disconnect is at least partly due to the inherent conflict between the need to measure and understand multiple parameters in vivo in order to optimize treatment, and the need for expedience in the clinic and in the regulatory and commercialization process. Thus, a methodical approach to selecting primary dosimetry metrics is required at each stage of translation of a treatment procedure, moving from complex measurements to understand PDT mechanisms in pre-clinical and early phase I trials, towards the identification and application of essential dose-limiting and/or surrogate measurements in phase II/III trials. If successful, identifying the essential and/or reliable surrogate dosimetry measurements should help facilitate increased adoption of clinical PDT. In this paper, examples of essential dosimetry points and surrogate dosimetry tools that may be implemented in phase II/III trials are discussed. For example, the treatment efficacy as limited by light penetration in interstitial PDT may be predicted by the amount of contrast uptake in CT, and so this could be utilized as a surrogate dosimetry measurement to prescribe light doses based upon pre-treatment contrast. Success of clinical ALA-based skin lesion treatment is predicted almost uniquely by the explicit or implicit measurements of photosensitizer and photobleaching, yet the individualization of treatment

  7. Results of the dosimetry intercomparison

    International Nuclear Information System (INIS)

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  8. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  9. 300 area TEDF permit compliance monitoring plan

    International Nuclear Information System (INIS)

    BERNESKI, L.D.

    1998-01-01

    This document presents the permit compliance monitoring plan for the 300 Area Treated Effluent Disposal Facility (TEDF). It addresses the compliance with the National Pollutant Discharge Elimination System (NPDES) permit and Department of Natural Resources Aquatic Lands Sewer Outfall Lease

  10. 300 area TEDF permit compliance monitoring plan

    Energy Technology Data Exchange (ETDEWEB)

    BERNESKI, L.D.

    1998-11-20

    This document presents the permit compliance monitoring plan for the 300 Area Treated Effluent Disposal Facility (TEDF). It addresses the compliance with the National Pollutant Discharge Elimination System (NPDES) permit and Department of Natural Resources Aquatic Lands Sewer Outfall Lease.

  11. PorTL - a compact, portable TLD reader for environmental and personal dosimetry

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Bodnar, L.; Csoke, A.; Feher, I.; Pazmandi, T.

    2005-01-01

    Thermoluminescent dosimeters (TLDs) are commonly used for environmental monitoring, for personal and medical dosimetry, for dosimetry in nuclear facilities, etc. Major advantages are their independence of the power supply, small dimension, sensitivity, good stability, wide measuring range, resistance to environmental changes and relatively low cost. The disadvantage is that the detector must be transported for evaluation to a laboratory equipped with a large, heavy and expensive TLD Reader operated by qualified personnel, which considerably increases the costs and delays results. To overcome this disadvantage, the KFKI Atomic Energy Research Institute (KFKI AEKI), in co-operation with BL Electronics (Hungary), has developed a new and unique TLD system containing a small, portable, battery powered and moderate-price reader for commercial use. This paper gives a detailed description and parameters of this system.(author)

  12. Nevada Test Site 2009 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    2010-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS). These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2009 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports. Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NTS. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. All gamma spectroscopy results for air particulates collected at the Area 3 and Area 5 RWMS were below the minimum detectable concentrations, and concentrations of americium and plutonium are only slightly above detection limits. The measured levels of radionuclides in air particulates and moisture are below derived concentration guides for these radionuclides. Radon flux from waste covers is well below regulatory limits. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. The 87.6 millimeters (mm) (3.45 inches (in.)) of precipitation at the Area 3 RWMS during 2009 is 43 percent below the average of 152.4 mm (6.00 in.), and the 62.7 mm (2.47 in.) of precipitation at the Area 5 RWMS during 2009 is 49 percent below the average of 122.5 mm (4.82 in.). Soil-gas tritium monitoring at borehole GCD-05 continues to show slow subsurface migration consistent with previous results. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation

  13. Facility effluent monitoring plan for K Area Spent Fuel. Revision 1

    International Nuclear Information System (INIS)

    Hunacek, G.S.

    1995-09-01

    The scope of this document includes program plans for monitoring and characterizing radioactive and nonradioactive hazardous materials discharged in the K Area effluents. This FEMP includes complete documentation for both airborne and liquid effluent monitoring systems that monitor radioactive and nonradioactive hazardous pollutants that could be discharged to the environment under routine and/or upset conditions. This documentation is provided for each K Area facility that uses, generates, releases, or manages significant quantities of radioactive and nonradioactive hazardous materials that could impact public and employee safety and the environment. This FEW describes the airborne and liquid effluent paths and the associated sampling and monitoring systems of the K Area facilities. Sufficient information is provided on the effluent characteristics and the effluent monitoring systems so that a compliance assessment against requirements may be performed. Adequate details are supplied such that radioactive and hazardous material source terms may be related to specific effluent streams which are, in turn, related to discharge points and finally compared to the effluent monitoring system capability

  14. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  15. Development and evaluation of gallium nitride-based thin films for x-ray dosimetry

    International Nuclear Information System (INIS)

    Hofstetter, Markus; Thalhammer, Stefan; Howgate, John; Sharp, Ian D; Stutzmann, Martin

    2011-01-01

    X-ray radiation plays an important role in medical procedures ranging from diagnostics to therapeutics. Due to the harm such ionizing radiation can cause, it has become common practice to closely monitor the dosages received by patients. To this end, precise online dosimeters have been developed with the dual objectives of monitoring radiation in the region of interest and improving therapeutic methods. In this work, we evaluate GaN thin film high electron mobility heterostructures with sub-mm 2 detection areas as x-ray radiation detectors. Devices were tested using 40-300 kV Bremsstrahlung x-ray sources. We find that the photoconductive device response exhibits a large gain, is almost independent of the angle of irradiation, and is constant to within 2% of the signal throughout this medical diagnostic x-ray range, indicating that these sensors do not require recalibration for geometry or energy. Furthermore, the devices show a high sensitivity to x-ray intensity and can measure in the air kerma rate (free-in-air) range of 1 μGy s -1 to 10 mGy s -1 with a signal stability of ±1% and a linear total dose response over time. Medical conditions were simulated by measurements of device responses to irradiation through human torso phantoms. Direct x-ray imaging is demonstrated using the index finger and wrist sections of a human phantom. The results presented here indicate that GaN-based thin film devices exhibit a wide range of properties, which make them promising candidates for dosimetry applications. In addition, with potential detection volumes smaller than 10 -6 cm 3 , they are well suited for high-resolution x-ray imaging. Moreover, with additional engineering steps, these devices can be adapted to potentially provide both in vivo biosensing and x-ray dosimetry.

  16. Dosimetry applications in GATE Monte Carlo toolkit.

    Science.gov (United States)

    Papadimitroulas, Panagiotis

    2017-09-01

    Monte Carlo (MC) simulations are a well-established method for studying physical processes in medical physics. The purpose of this review is to present GATE dosimetry applications on diagnostic and therapeutic simulated protocols. There is a significant need for accurate quantification of the absorbed dose in several specific applications such as preclinical and pediatric studies. GATE is an open-source MC toolkit for simulating imaging, radiotherapy (RT) and dosimetry applications in a user-friendly environment, which is well validated and widely accepted by the scientific community. In RT applications, during treatment planning, it is essential to accurately assess the deposited energy and the absorbed dose per tissue/organ of interest, as well as the local statistical uncertainty. Several types of realistic dosimetric applications are described including: molecular imaging, radio-immunotherapy, radiotherapy and brachytherapy. GATE has been efficiently used in several applications, such as Dose Point Kernels, S-values, Brachytherapy parameters, and has been compared against various MC codes which are considered as standard tools for decades. Furthermore, the presented studies show reliable modeling of particle beams when comparing experimental with simulated data. Examples of different dosimetric protocols are reported for individualized dosimetry and simulations combining imaging and therapy dose monitoring, with the use of modern computational phantoms. Personalization of medical protocols can be achieved by combining GATE MC simulations with anthropomorphic computational models and clinical anatomical data. This is a review study, covering several dosimetric applications of GATE, and the different tools used for modeling realistic clinical acquisitions with accurate dose assessment. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. The dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    1987-01-01

    Describes the activities of the IAEA's Dosimetry Laboratory which provides calibration and comparison services for secondary standard dosimetry laboratories (SSDLs) of Member States. In addition, a joint IAEA/WHO postal dosimetry service has been established for radiotherapy centers. The International Measurement System and the calibration ''chain'' from measurement standard instruments of the International Bureau of Weights and Measurements (BIPM) through the primary and secondary standards to the dosimeters of the users are presented as well

  18. Optically stimulated luminescence dosimetry performance of natural Brazilian topaz exposed to beta radiation

    International Nuclear Information System (INIS)

    Bernal, R.; Souza, D. N.; Valerio, M. E. G.; Cruz-Vazquez, C.; Barboza-Flores, M.

    2006-01-01

    Optically stimulated luminescence (OSL) has become the technique of choice in many areas of dosimetry. Natural materials like topaz are available in large quantities in Brazil and other countries. They have been studied to investigate the possibility of use its thermoluminescence (TL) properties for dosimetric applications. In this work, we investigate the possibility of utilising the OSL properties of natural Brazilian topaz in dosimetry. Bulk topaz samples were exposed to doses up to 100 Gy of beta radiation and the integrated OSL as a function of the dose showed linear behaviour. The fading occurs in the first 20 min after irradiation but it is <6% of the integrated OSL measured shortly after exposure. We conclude that natural colourless topaz is a very suitable phosphor for OSL dosimetry. (authors)

  19. Status report on dosimetry benchmark neutron field development, characterization, and application

    International Nuclear Information System (INIS)

    Fabry, A.; Grundl, J.A.; McElroy, W.N.; Lippincott, E.P.; Farrar, H. IV.

    1977-01-01

    The report attempts to present a brief, but comprehensive review of the status and future directions of benchmark neutron field development, characterization and application in perspective with two major objectives of reactor dosimetry: (1) fuel fission rate and burn-up passive monitoring, and (2) correlation of materials irradiation damage effects and projection to commercial power plants. The report focuses on the Light Water Reactor and Fast Breeder Reactor program needs

  20. Nevada Test Site 2007 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    NSTec Environmental Management

    2008-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2007 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2007a; 2008; Warren and Grossman, 2008). Direct radiation monitoring data indicate exposure levels at the RWMSs are at background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. A single gamma spectroscopy measurement for cesium was slightly above the minimum detectable concentration, and concentrations of americium and plutonium are only slightly above detection limits at the Area 3 RWMS. The measured levels of radionuclides in air particulates are below derived concentration guides for these radionuclides. Radon flux from waste covers is well below regulatory limits. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. The 136.8 millimeters (mm) (5.39 inches [in.]) of precipitation at the Area 3 RWMS during 2007 is 13 percent below the average of 158.1 mm (6.22 in.), and the 123.8 mm (4.87 in.) of precipitation at the Area 5 RWMS during 2007 is 6 percent below the average of 130.7 mm (5.15 in.). Soil-gas tritium monitoring at borehole GCD-05U continues to show slow subsurface migration consistent with previous results. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward movement percolation of precipitation more effectively

  1. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  2. Required accuracy and dose thresholds in individual monitoring

    DEFF Research Database (Denmark)

    Christensen, P.; Griffith, R.V.

    1994-01-01

    this uncertainty factor, a value of 21% can be evaluated for the allowable maximum overall standard deviation for dose measurements at dose levels near the annual dose limits increasing to 45% for dose levels at the lower end of the dose range required to be monitored. A method is described for evaluating...... the overall standard deviation of the dosimetry system by combining random and systematic uncertainties in quadrature, and procedures are also given for determining each individual uncertainty connected to the dose measurement. In particular, attention is paid to the evaluation of the combined uncertainty due...... to energy and angular dependencies of the dosemeter. In type testing of personal dosimetry systems, the estimated overall standard deviation of the dosimetry system is the main parameter to be tested. An important characteristic of a personal dosimetry system is its capability of measuring low doses...

  3. A new development in personnel monitoring

    International Nuclear Information System (INIS)

    Fletcher, R.J.

    1993-01-01

    For several years the UK National Radiological Protection Board (NRPB) has felt that the next major development in personal dosimetry should be an electronic dosemeter which would read out directly, to improve control of exposures and achieve a reduction in individual doses. This became a possibility when an arrangement of solid-state detectors and filters was developed at the NRPB which was suitable for the measurement of the individual photon dose equivalent. Since then, further development has taken place at the NRPB for the measurement of the individual dose equivalent superficial for β-radiation. The measurements are made in the quantities Hp(10) and Hs(0.07), as recommended by the ICRU for individual monitoring. Thus, the basic detector system for the development of an electronic dosemeter has been established. The device is now being manufactured and marketed. An electronic personal dosimetry service is described, together with the procedure which is being adopted to gain approval in the UK for monitoring the exposure of classified workers. The NRPB considers this to be the next logical development in personal dosimetry, and it has been shown that the device offers a number of advantages for this purpose. (Author)

  4. Technical recommendations for the use of thermoluminescence for dosimetry in individual monitoring for photons and electrons from external sources

    International Nuclear Information System (INIS)

    1975-01-01

    The principles of thermoluminescence dosimetry and the role it may play in the field of personnel dosimetry are presented. Technical recommendations are made as an indication of what is generally regarded as good practice and they are intended to be of assistance in avoiding the common sources of error. Errors due to: the detector; the evaluation procedure; the thermal treatment; at the sensitivity of the detector to neutrons. The recommendations are concerned with: the choice of detector material; design of thermoluminescent dosemeters; read-out procedure; reader; handling procedures; dose evaluations; automation; documentation and data handling

  5. Development and current state of dosimetry in Cuba

    International Nuclear Information System (INIS)

    Prieto Miranda, E.F.; Cuesta Fuente, G.; Chavez Ardanza, A.

    1999-01-01

    In Cuba, the application of the radiation technologies has been growing in the last years, and at present there are several dosimetry systems with different ranges of absorbed dose. Diverse researches were carried out on high dose dosimetry with the following dosimetry systems: Fricke, ceric-cerous sulfate, ethanol-chlorobenzene, cupric sulfate and Perspex (Red 4034 AE and Clear HX). In this paper the development achieved during the last 15 years in the high dose dosimetry for radiation processing in Cuba is presented, as well as, the current state of different dosimetry systems employed for standardization and for process control. The paper also reports the results of dosimetry intercomparison studies that were performed with the Ezeiza Atomic Center of Argentine and the International Dose Assurance Service (IDAS) of IAEA. (author)

  6. Miniature semiconductor detectors for in vivo dosimetry

    International Nuclear Information System (INIS)

    Rosenfeld, A. B.; Cutajar, D.; Lerch, M. L. F.; Takacs, G.; Cornelius, I. M.; Yudelev, M.; Zaider, M.

    2006-01-01

    Silicon mini-semiconductor detectors are found in wide applications for in vivo personal dosimetry and dosimetry and Micro-dosimetry of different radiation oncology modalities. These applications are based on integral and spectroscopy modes of metal oxide semiconductor field effect transistor and silicon p-n junction detectors. The advantages and limitations of each are discussed. (authors)

  7. Performance test of personal RF monitor for area monitoring at magnetic confinement fusion facility

    International Nuclear Information System (INIS)

    Tanaka, M.; Uda, T.; Wang, J.; Fujiwara, O.

    2012-01-01

    For safety management at a magnetic confinement fusion-test facility, protection from not only ionising radiation, but also non-ionising radiation such as the leakage of static magnetic and electromagnetic fields is an important issue. Accordingly, the use of a commercially available personal RF monitor for multipoint area monitoring is proposed. In this study, the performance of both fast- and slow-type personal RF monitors was investigated by using a transverse electromagnetic cell system. The range of target frequencies was between 10 and 300 MHz, corresponding to the ion cyclotron range of frequency in a fusion device. The personal RF monitor was found to have good linearity, frequency dependence and isotropic response. However, the time constant for the electric field sensor of the slow-type monitor was much longer than that for the fast-type monitor. Considering the time-varying field at the facility, it is found that the fast-type monitor is suitable for multipoint monitoring at magnetic confinement fusion test facilities. (authors)

  8. Internal Dosimetry for Nuclear Power Program

    International Nuclear Information System (INIS)

    Wo, Y.M.

    2011-01-01

    Internal dosimetry which refers to dosage estimation from internal part of an individual body is an important and compulsory component in order to ensure the safety of the personnel involved in operational of a Nuclear Power Program. Radionuclides particle may deposit in the human being through several pathways and release wave and/or particle radiation to irradiate that person and give dose to body until it been excreted or completely decayed from the body. Type of radionuclides of concerning, monitoring program, equipment's and technique used to measure the concentration level of such radionuclides and dose calculation will be discussed in this article along with the role and capability of Malaysian Nuclear Agency. (author)

  9. Dosimetry and narrow X-ray beams, produced by particle linear accelerator for use in radiosurgery

    International Nuclear Information System (INIS)

    Campos, J.C.F.; Vizeu, D.M.

    1987-01-01

    The principal characteristics of dosimetry and narrow X-ray beams(4Mv) monitoring are investigated for use in estereotatic radiosurgery. An additional collimator system and a estereotatic system (Leksell type) are presented. Dosimetric parameters like tissue-air ratio, peak scatter factor, isodose curves are studied. (M.A.C.) [pt

  10. Statistical methods to evaluate thermoluminescence ionizing radiation dosimetry data

    International Nuclear Information System (INIS)

    Segre, Nadia; Matoso, Erika; Fagundes, Rosane Correa

    2011-01-01

    Ionizing radiation levels, evaluated through the exposure of CaF 2 :Dy thermoluminescence dosimeters (TLD- 200), have been monitored at Centro Experimental Aramar (CEA), located at Ipero in Sao Paulo state, Brazil, since 1991 resulting in a large amount of measurements until 2009 (more than 2,000). The data amount associated with measurements dispersion, since every process has deviation, reinforces the utilization of statistical tools to evaluate the results, procedure also imposed by the Brazilian Standard CNEN-NN-3.01/PR- 3.01-008 which regulates the radiometric environmental monitoring. Thermoluminescence ionizing radiation dosimetry data are statistically compared in order to evaluate potential CEA's activities environmental impact. The statistical tools discussed in this work are box plots, control charts and analysis of variance. (author)

  11. Radiation chemical dosimetry by means of nitrate-nitrite; Dosimetria quimica de la radiacion aplicacion del sistema nitrato-nitrito

    Energy Technology Data Exchange (ETDEWEB)

    Tormo Ferrero, M J

    1977-07-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolysis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (Author) 22 refs.

  12. Chemical dosimetry system for criticality accidents.

    Science.gov (United States)

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.

  13. Dosimetry for radiation processing. Final report of the co-ordinated research project on characterization and evaluation of high dose dosimetry techniques for quality assurance in radiation processing

    International Nuclear Information System (INIS)

    2000-06-01

    In many Member States the use of large cobalt-60 gamma ray facilities and electron beam accelerators with beam energies from about 0.1 to 10 MeV for industrial processing continues to increase. For these processes, quality assurance relies on the application of well established dosimetry systems and procedures. This is especially the case for health regulated processes, such as the radiation sterilization of health care products, and the irradiation of food to eliminate pathogenic organisms or to control insect pests. A co-ordinated research project (CRP) was initiated by the IAEA in June 1995. Research contracts and research agreements in areas of high dose dosimetry were initiated to meet these challenges. The major goals of this CRP were to investigate the parameters that influence the response of dosimeters and to develop reference and transfer dosimetry techniques, especially for electron beams of energy less than 4 MeV and for high energy X ray sources (up to 5 MV). These will help to unify the radiation measurements performed by different radiation processing facilities and other high dose dosimetry users in Member States and encourage efforts to obtain traceability to primary and secondary standards laboratories. It will also aim to strengthen and expand the present International Dose Assurance Service (IDAS) provided by the IAEA

  14. Aircraft crew individual dosimetry of Czech air companies: 1998-2004 overview

    International Nuclear Information System (INIS)

    Spurny, F.; Malusek, A.; Kovar, I.; Orcikova, H.; Ploc, O.

    2006-01-01

    TICRP Publication 60 recommends that where applicable, radiation exposure due to the cosmic component at high altitudes be considered as part of occupational exposure to ionizing radiation. This recommendation was incorporated into Czech legislation in 1997, and studies on how to perform individual dosimetry of Czech companies aircrew started immediately. Individual monitoring is performed by calculation using the CARI transport code. The results obtained since the beginning of the monitoring period have been recalculated now by using the most recent CARI 6 version and are presented in the form of the effective dose. Information on the flight schedules and on the aircrew present during the flights was obtained from the air company. Routine individual dosimetry started in 1998. The main results for the 1998 - 2004 period are as follows: (i) Both the relative effective dose distribution and the average annual effective doses vary from company to company and from year to year. Since 2000, the average effective doses seem to have been increasing constantly. (ii) The collective dose has been increasing constantly up to a value of 3 manSv in 2004. More detailed analysis is presented, including verification of the routine procedure through a series of onboard experimental measurements performed in 2005. (orig.)

  15. Dosimetry as an integral part of radiation processing

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1999-01-01

    Different connections between high-dose dosimetry and radiation processing are discussed. Radiation processing cannot be performed without proper dosimetry. Accurate high dose and high dose rate dosimetry exhibits several aspects: first of all it is the preservation of the quality of the product, then fulfillment of legal aspects and last but not the least the safety of processing. Further, seldom discussed topics are as follow: dosimetric problems occurring with double-side EB irradiations, discussed in connection with the deposition of electric charge during electron beam irradiation. Although dosimetry for basic research and for medical purposes are treated here only shortly, some conclusions reached from these fields are considered in dosimetry for radiation processing. High-dose dosimetry of radiation has become a separate field, with many papers published every year, but applied dosimetric projects are usually initiated by a necessity of particular application. (author)

  16. MONITORING CONCEPTS FOR COASTAL AREAS USING LIDAR DATA

    Directory of Open Access Journals (Sweden)

    A. Schmidt

    2013-05-01

    Full Text Available Coastal areas are characterized by high spatial and temporal variability. In order to detect undesired changes at early stages, enabling rapid countermeasures to mitigate or minimize potential harm or hazard, a recurrent monitoring becomes necessary. In this paper, we focus on two monitoring task: the analysis of morphological changes and the classification and mapping of habitats. Our concepts are solely based on airborne lidar data which provide substantial information in coastal areas. For the first task, we generate a digital terrain model (DTM from the lidar point cloud and analyse the dynamic of an island by comparing the DTMs of different epochs with a time difference of six years. For the deeper understanding of the habitat composition in coastal areas, we classify the lidar point cloud by a supervised approach based on Conditional Random Fields. From the classified point cloud, water-land-boundaries as well as mussel bed objects are derived afterwards. We evaluate our approaches on two datasets of the German Wadden Sea.

  17. Thyroid monitoring for residents of disaster-affected and neighboring areas

    International Nuclear Information System (INIS)

    Ito, Shigeki

    2014-01-01

    The devastating environmental contamination caused by the nuclear disaster at the Fukushima Daiichi Nuclear Power Station of The Tokyo Electric Power Company is exposing the residents of the disaster-affected areas to health risks attributable to radiation exposure, and fear of the development of 131 I-induced thyroid cancer, which is a stochastic effect of radiation and is particularly high. As part of the response to nuclear disasters by the government of the municipality where the nuclear power station is located and in operation and by the governments of neighboring municipalities, it is necessary to conduct thyroid monitoring for the purpose of alleviating the fears of residents of the disaster-affected areas as well as those living in the contaminated, even if only slightly, neighboring areas (local residents). This health monitoring needs to be implemented without delay in the case of a disaster along with dissemination of a portable type thyroid monitoring system available at evacuation centers, etc. for assessing thyroid exposure doses. The establishment of a system for developing personnel ready to perform monitoring is also essential. Assessing thyroid exposure doses is indispensable as a means of assuring local residents not only of safety but also of security from the risks of radiation. To date, contamination has not been detected in people, except for residents contaminated by a large amount of iodine, by employing the mobile type of thyroid monitoring system. However, when local residents seeking security desire thyroid monitoring, it is preferable that a portable type simplified thyroid monitoring system be used as a means of ensuring security against radiation. (author)

  18. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  19. Nevada Test Site 2005 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    David B. Hudson, Cathy A. Wills

    2006-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2005 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2005; Grossman, 2005; Bechtel Nevada, 2006). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and concentrations of americium and plutonium are only slightly above detection limits at the Area 3 RWMS. Measurements at the Area 5 RWMS show that radon flux from waste covers is no higher than natural radon flux from undisturbed soil in Area 5. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. Precipitation during 2005 totaled 219.1 millimeters (mm) (8.63 inches [in.]) at the Area 3 RWMS and 201.4 mm (7.93 in.) at the Area 5 RWMS. Soil-gas tritium monitoring continues to show slow subsurface migration consistent with previous results. Moisture from precipitation at Area 5 has percolated to the bottom of the bare-soil weighing lysimeter, but this same moisture has been removed from the vegetated weighing lysimeter by evapotranspiration. Vadose zone data from the operational waste pit covers show that precipitation from the fall of 2004 and the spring of 2005 infiltrated past the deepest sensors at 188 centimeters (6.2 feet) and remains in the pit cover

  20. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  1. Results of the Argentinian intercomparison on internal dosimetry – 2014. Interpretation of monitoring data for effective dose assessment due to internal exposure

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the models applied and the results consistency. To that aim, in 2014 the National Intercomparison Exercise was organized and coordinated by the Internal Dosimetry Laboratory of the Nuclear Regulatory Authority (ARN) of Argentina. Four simulated cases covering intakes of “1”3”1I, “1”3”7Cs and tritium were proposed. The exercise counted with the participation of four internal dosimetry services from the nuclear power plants (NA-SA CNA and NA-SA CNE) and the CNEA Atomic Centres: Bariloche (CAB) and Ezeiza (CAE). This report shows a complete analysis of the participant’s results in this exercise. (authors) [es

  2. The role of the National Physical Laboratory in monitoring and improving dosimetry in UK radiotherapy

    International Nuclear Information System (INIS)

    Thomas, R.A.S.; Duane, S.; McEwen, M.R.; Rosser, K.E.

    2002-01-01

    In the UK, the National Physical Laboratory, in collaboration with the Institute for Physics and Engineering in Medicine operates an audit programme to ensure national consistency in radiotherapy dosimetry. The present programme covers dosimetry of megavoltage photons and electrons (3-19 MeV) and low and medium energy (10-300 kV) photons. The aim of each audit is to verify the local measurement of absorbed dose at the radiotherapy centre. The audit measurements - principally beam quality and linac output - are made following the same protocol as the clinic but using different equipment. The audit is not an absolute measurement of the absorbed dose but amounts to a check that the equipment used by the centre is operating as expected and that the Code of Practice is being followed correctly. The protocols used in the UK are IPSM 1990 for high-energy photons, IPEMB 1996 for electrons and IPEMB 1996 for low energy photons. For the purpose of these audits, NPL maintains a set of calibrated ionisation chambers

  3. Radiation Protection Control Area Around Baggage Control X-ray Units

    International Nuclear Information System (INIS)

    Prlic, I.; Radalj, Z.; Milkovic-Kraus, S.; Cerovac, Z.

    2003-01-01

    The importance of prompt occupational dose reporting rises when dose is received within a short-time interval or when the radiation source suffers any technical failures. Radiation exposure is to be recognized as a private/or group hazard of each person alone. Actual radiation quality of the source is to be taken into account. To optimize the radiological radiation protection Quality Control measurements of the source are done. We have developed digital dosemeters of type ALARA OD2 for external dosimetry to be used for establishing the real pattern of occupational dose delivered to the workers or/and as the (Ort) professional environmental measuring station. We are using dosemeter to define the control areas and areas of concern - point (Ort) around the source. This upgrade to legal obligatory external (film badge) dosimetry will help us to ease defining the professional stuff and working places which are actually exposed to ionising radiation of concern and for which it is necessary to provide legally required, or even additional, occupational health care programme. This means the analysis of exposure situations for specific jobs near the X-ray equipment used for baggage control in the context of carrying out a detailed study for the optimisation of radiation protection. PC data readout from device forms a real time exposure dose rate pattern that proves that any worker or other employee working nearby the baggage X-ray unit is not obliged to undergo any legal occupational monitoring (dosimetry or health) hence the total dose per year will not exceed 1 mSv under the worst working conditions. (author)

  4. Liulin-type spectrometry-dosimetry instruments

    International Nuclear Information System (INIS)

    Dachev, T.; Dimitrov, P.; Tomov, B.; Matviichuk, Y.; Spurny, F.; Ploc, O.; Brabcova, K.; Jadrnickova, I.

    2011-01-01

    The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-ion accelerators and CERN-EC high-energy reference field. Since 2000, LSDIs have been used in the scientific programmes of four manned space flights on the American Laboratory and ESA Columbus modules and on the Russian segment of the International Space Station, one Moon spacecraft and three spacecraft around the Earth, one rocket, two balloons and many aircraft flights. In addition to relative low price, LSDIs have proved their ability to qualify the radiation field on the ground and on the above-mentioned carriers. (authors)

  5. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Directory of Open Access Journals (Sweden)

    Hu J.-P.

    2016-01-01

    Full Text Available Radiation dosimetry for Neutron Capture Therapy (NCT has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR. In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1 in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2 out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3 beam shutter upgrade to reduce strayed neutrons and gamma dose, (4 beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5 beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates to reduce prompt gamma and fast neutron doses, (6 sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7 holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4–7

  6. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J. P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holden, N. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reciniello, R. N.

    2014-05-23

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7

  7. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  8. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  9. Precision dosimetry system suited for low temperature radiation damage experiments

    DEFF Research Database (Denmark)

    Andersen, H.H.; Hanke, C.C.; Sørensen, H.

    1967-01-01

    A calorimetric system for dosimetry on a beam of charged particles is described. The calorimeter works at liquid helium temperature. The total dose may be measured with an accuracy of 0.3%, and the dose per area with 0.4%. No theoretical corrections are needed. © 1967 The American Institute...

  10. An overview on extremity dosimetry in medical applications

    International Nuclear Information System (INIS)

    Vanhavere, F.; Carinou, E.; Donadille, L.; Ginjaume, M.; Jankowski, J.; Rimpler, A.; Sans Merce, M.

    2008-01-01

    Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some of these applications, the skin of the fingers is the limiting organ for individual monitoring of external radiation. Therefore, sub-group 1 of WG9 deals with the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in a medical environment together with the difficulties in measuring a local dose that is representative for the maximum skin dose, usually with one single detector, makes it difficult to perform accurate extremity dosimetry. Sub-group 1 worked out a thorough literature review on extremity dosimetry issues in diagnostic and therapeutic nuclear medicine and positron emission tomography, interventional radiology and interventional cardiology and brachytherapy. Some studies showed that the annual dose limits could be exceeded if the required protection measures are not taken, especially in nuclear medicine. The continuous progress in new applications and techniques requires an important effort in radiation protection and training. (authors)

  11. Implementation of a post graduated course in radiation protection and dosimetry

    International Nuclear Information System (INIS)

    Papa, A.R.R.; Rodrigues, L.N.; Godoy, J.M.O.; Fonseca, E.S. da; Pereira, W.W.; Dantas, B.M.; Goncalves, M. G.

    2001-01-01

    The main motivations and followed lines in the implementation of a postgraduate course in Radiation Protection and Dosimetry are exposed. The principal research areas as well as the academic program are described. A prevision on the future and perspectives of the program is done. (author)

  12. Performing personnel dosimetry investigations and records quality assurance

    International Nuclear Information System (INIS)

    Perle, S.C.

    2002-01-01

    Radiation Safety Officers (RSOs) sometimes face situations in which personnel dosimetry estimates are required after dosimeters issued to radiation workers (film or TLD badges, extremity dosimeters, etc.) are lost or damaged before processing. This article was prepared to help those involved with personnel dosimetry investigations became aquatinted with this process. A factor that contributes to the anxiety of those unfamiliar with dosimetry investigations is the lack of published guidance available in this subject. More printed resources are needed to help radiation safety professionals familiarize themselves and understand personnel dosimetry investigations. Topics discussed in this presentation include the justification of performing dosimetry investigations, recommendations on how to perform them and the advantages of performing such investigations

  13. Dosimetry and Shielding of X and Gamma Radiation

    International Nuclear Information System (INIS)

    Oncescu, M.; Panaitescu, I.

    1992-01-01

    This book covers the following problems: 1. X and Gamma radiations, 2. Interaction of X-ray and gamma radiations with matter, 3. Interaction of electrons with matter, 4. Principles and basic concepts of dosimetry, 5. Ionization dosimetry, 6. Calorimetric chemical and photographic dosimetry, 7. Solid state dosimetry, 8. Computation of dosimetric quantities, 9. Dosimetry in radiation protection, 10. Shielding of X and gamma radiations. The authors, well-known Romanian experts in Radiation Physics and Engineering, gave an up-dated, complete and readable account of this subject matter. The analyses of physical principles and concepts, of materials and instruments and of computational methods and applications are all well balanced to meat the needs of a broad readership

  14. Radiotherapy Based On α Emitting Radionuclides: Geant4 For Dosimetry And Micro-/Nano-Dosimetry

    International Nuclear Information System (INIS)

    Guatelli, Susanna

    2013-01-01

    Possible physics approaches to evaluate the efficacy of TAT are dosimetry, microdosimetry and nanodosimetry. Dosimetry is adequate when mean absorbed dose to a macroscopic target volume is important to understand the biological effect of radiation. General purpose Monte Carlo (MC) codes, based on condensed history approach, are a very useful, cost effective tool to solve dosimetric problems. The condensed history approach is based on the use of multiple scattering theories to calculate the energy losses and angular changes in the direction of the particle. The short α particle range and high LET make the microdosimetric approach more suitable than dosimetry to study TAT from first physics principles, as this approach takes into account the stochastic nature of energy deposition at cellular level

  15. Updating the INDAC computer application of internal dosimetry

    International Nuclear Information System (INIS)

    Bravo Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Sanudo, E.; Serrano Calvo, E.

    2013-01-01

    The initial objective of this project is to expand the application INDAC currently used in internal dosimetry services of the Spanish nuclear power plants and Tecnatom for estimating the effective doses of internal dosimetry of workers in direct action. or in-vivo dosimetry. (Author)

  16. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  17. Real time monitoring of electron processors

    International Nuclear Information System (INIS)

    Nablo, S.V.; Kneeland, D.R.; McLaughlin, W.L.

    1995-01-01

    A real time radiation monitor (RTRM) has been developed for monitoring the dose rate (current density) of electron beam processors. The system provides continuous monitoring of processor output, electron beam uniformity, and an independent measure of operating voltage or electron energy. In view of the device's ability to replace labor-intensive dosimetry in verification of machine performance on a real-time basis, its application to providing archival performance data for in-line processing is discussed. (author)

  18. Nevada National Security Site 2010 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

    International Nuclear Information System (INIS)

    2011-01-01

    Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada National Security Site (NNSS). These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2010 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2010a; 2010b; 2011). Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. All gamma spectroscopy results for air particulates collected at the Area 3 and Area 5 RWMS were below the minimum detectable concentrations, and concentrations of americium and plutonium are only slightly above detection limits. The measured levels of radionuclides in air particulates and moisture are below derived concentration guides for these radionuclides. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. The 246.9 millimeters (mm) (9.72 inches [in.]) of precipitation at the Area 3 RWMS during 2010 is 56 percent above the average of 158.7 mm (6.25 in.), and the 190.4 mm (7.50 in.) of precipitation at the Area 5 RWMS during 2010 is 50 percent above the average of 126.7 mm (4.99 in.). Soil-gas tritium monitoring at borehole GCD-05 continues to show slow subsurface migration consistent with previous results. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than

  19. Radiation dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  20. An IAEA Survey of Dosimetry Audit Networks for Radiotherapy

    International Nuclear Information System (INIS)

    Grochowska, Paulina; Izewska, Joanna

    2013-01-01

    A Survey: In 2010, the IAEA undertook a task to investigate and review the coverage and operations of national and international dosimetry audit programmes for radiotherapy. The aim was to organize the global database describing the activities of dosimetry audit networks in radiotherapy. A dosimetry audit questionnaire has been designed at an IAEA consultants' meeting held in 2010 for organizations conducting various levels of dosimetry audits for radiotherapy. Using this questionnaire, a survey was conducted for the first time in 2010 and repeated in 2011. Request for information on different aspects of the dosimetry audit was included, such as the audit framework and resources, its coverage and scope, the dosimetry system used and the modes of audit operation, i.e. remotely and through on-site visits. The IAEA questionnaire was sent to over 80 organizations, members of the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories (SSDLs) and other organizations known for having operated dosimetry audits for radiotherapy in their countries or internationally. Survey results and discussion: In response to the IAEA survey, 53 organizations in 45 countries confirmed that they operate dosimetry audit services for radiotherapy. Mostly, audits are conducted nationally, however there are five organizations offering audits abroad, with two of them operating in various parts of the world and three of them at the regional level, auditing radiotherapy centres in neighbouring countries. The distribution of dosimetry audit services in the world is given. (author)