WorldWideScience

Sample records for air curtains

  1. Effect of Air-Curtain Discharge Speed on the Effectiveness of Vortex-like Air-Curtain Approach for Severe Accident Management

    International Nuclear Information System (INIS)

    Ullah, Sana; Yim, Man Sung

    2017-01-01

    The purpose of air-curtain installation is to isolate reactor containment from outside environment, confine the leaking radioactive material in a localized area, and minimize the impact of outside wind. The wind could blow away airborne radioactive material immediately after discharge leaving little room for effective capturing. Therefore, vortex-like air-curtain plays an important role in this process, and its effectiveness could severely influence the performance of overall system. An approach based on vortex-like air-curtain was proposed earlier for preventing spread of radioactive material to the environment and mitigate subsequent radiological consequences. Effect of air-curtain discharge speed, and discharge angle was studied, and a quantitative account of air curtain in terms of effectiveness parameter was performed in this work. It was found that for given wind speed, air-curtain effectiveness would improve with increase in air-curtain discharge speed to an extent, after which any increase in discharge velicity could deteriorate the performance, due to imbalance between discharge and wind speed. Keeping air-curtain discharge at an angle of 15° opposite to the predominant flow direction is devised.

  2. The Solar Dynamic Buffer Zone (SDBZ) curtain wall: Validation and design of a solar air collector curtain wall

    Science.gov (United States)

    Richman, Russell Corey

    Given the increases in both the environmental and economic costs of energy, there is a need to design and building more sustainable and low-energy building systems now. Curtain wall assemblies show great promise---the spandrel panels within them can be natural solar collectors. By using a Solar Dynamic Buffer Zone (SDBZ) in the spandrel cavity, solar energy can be efficiently gathered using the movement of air. There is a need for a numerical model capable of predicting performance of an SDBZ Curtain Wall system. This research designed, constructed and quantified a prototype SDBZ curtain wall system through by experimental testing in a laboratory environment. The laboratory experiments focussed on three main variables: air flow through the system, incoming radiation and collector surface type. Results from the experimental testing were used to validate a one-dimensional numerical model of the prototype. Results from this research show a SDBZ curtain wall system as an effective means of reducing building heating energy consumption through the preheating of incoming exterior ventilation air during the heating season in cold climates. The numerical model showed good correlation with experimental results at higher operating flows and at lower flows when using an apparent velocity at the heat transfer boundary layer. A seasonal simulation for Toronto, ON predicted energy savings of 205 kWh/m2 with an average seasonal efficiency of 28%. This is considered in the upper range when compared to other solar air collectors. Given the lack of published literature for similar systems, this research acts to introduce a simple, innovative approach to collect solar energy that would otherwise be lost to the exterior using already existing components within a curtain wall. Specifically, the research has provided: results from experiments and simulation, a first generation numerical model, aspects of design and construction of the SDBZ curtain wall and specific directions for further

  3. Ambience control by air-curtains; Controle d'ambiance par rideaux d'air

    Energy Technology Data Exchange (ETDEWEB)

    Blanchet, F.X.; Gouriou, Y.; Gupta, S.; Pavageau, M.; Solliec, C. [Ecole des Mines de Nantes, UMR 6144 CNRS-EMN-Univ. de Nantes, Dept. Systemes Energetiques et Environnement, 44 (France); Cassin, C.; Maubert, P.; Rey, C. [Aix-Marseille-3 Univ. Paul Cezanne, IUT de Saint Jerome, Dept. GTE, 13 - Marseille (France)

    2005-08-01

    Air curtains are plane air jets blown across openings so as to isolate from each other two adjacent volumes. Such apparatus are commonly used in applications where it is sought to minimise heat or mass transfers between two areas while it is necessary to keep free the way for people or material from one area to the next one. Experimental facilities were designed to investigate various air-curtain arrangements with the aim to work out efficient solutions for energy saves or smoke confining in case of fire in a road tunnel. In the first stage, the emphasis was put on flow dynamics. The different configurations considered in this work include systems made of one or two curtains of single or double jets. They were specifically designed to perform measurements using Particle Image Velocimetry (PIV). (authors)

  4. Experimental investigations of an air curtain device subjected to external perturbations

    International Nuclear Information System (INIS)

    Havet, M.; Rouaud, O.; Solliec, C.

    2003-01-01

    Although plane air jets are often used as dynamic barriers to separate two environments, only a few works have explored their sensitivity to perturbations. We investigated the influence of sharp changes of pressure on the flow field of a device designed to avoid air-borne contamination. Laser tomography and tracer gas experiments clearly indicate that the air curtain is strongly sensitive to perturbations such as draughts. The results highlight that the control of air curtains used in open protection devices should be further investigated

  5. Air curtain incinerator equipment performance evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    About 50 tonnes of oil-contaminated debris and related wood products were successfully incinerated in a 10-h performance evaluation of a mobile air curtain incinerator. The test was conducted to evaluate the incinerator's ability to combust oil-contaminated trash and debris obtained from oil spill sites. The operating principle of the apparatus involves a diesel engine driving an air blower to deliver ca 20,000 scfm of air into a 5-m long manifold angled at a 30{degree} slope into an incineration tank. A bottomhole aerator is lowered to the bottom of the tank and compressed air is injected into the aerator to control burn efficiency. The blower is engaged once the debris in the tank is burning sufficiently after starting a fire in the debris. The air curtain effect created by the air deflecting off the opposite wall from the blower manifold and bouncing off the bottom and up the side of the incineration tank results in repeated combustion of the gases, thereby significantly reducing the degree of visible smoke emission. The unit is capable of incinerating ca 5 tonnes/h and of generating ca 16 m{sup 3}/h of hot water which can be used for flushing spill sites and cleaning shorelines. 12 figs.

  6. The results of air treatment process modeling at the location of the air curtain in the air suppliers and ventilation shafts

    Directory of Open Access Journals (Sweden)

    Nikolaev Aleksandr

    2017-01-01

    Full Text Available In the existing shaft air heater installations (AHI, that heat the air for air suppliers in cold seasons, a heater channel is used. Some parts of the air from the heater go to the channel, other parts are sucked through a pithead by the general shaft pressure drawdown formed by the main ventilation installation (MVI. When this happens, a mix of two air flows leads to a shaft heat regime violation that can break pressurization of intertubular sealers. The problem of energy saving while airing underground mining enterprises is also very important. The proposed solution of both tasks due to the application of an air curtain is described in the article. In cold seasons the air treatment process should be used and it is offered to place an air curtain in the air suppliers shaft above the place of interface of the calorifer channel to a trunk in order to avoid an infiltration (suction of air through the pithead. It’s recommended to use an air curtain in a ventilation shaft because it reduces external air leaks thereby improving energy efficiency of the MVI work. During the mathematical modeling of ventilation and air preparation process (in SolidWorks Flowsimulation software package it was found out that the use of the air curtain in the air supply shaft can increase the efficiency of the AHI, and reduce the electricity consumption for ventilation in the ventilation shaft.

  7. 40 CFR 60.1445 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1445 Section 60.1445 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1445 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If your air curtain incinerator combusts...

  8. Utilizing adequate intake line curtain air quantities to maintain respirable dust compliance

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, M.J.; Tomko, D.M.; Rumbaugh, V.E. [United States Dept. of Labor, Mine Safety and Health Administration, Pittsburgh, PA (United States). Safety and Health Technical Center

    2010-07-01

    Mine operators are obligated to ensure the effectiveness of their dust controls and implement practices to minimize the generation of dust in their mines. The 2 main types of face ventilation are blowing and exhaust ventilation. With blowing face ventilation, intake air is directed behind a line curtain or through ventilation tubing and then discharged from the end of the line curtain toward the working face. This paper presented specific information for mine operators regarding where and when exhausting or blowing ventilation will be used. Mine operators should establish the line curtain for directing the face ventilating air as a specific distance from the point of deepest penetration of the face. The location of curtains where roof bolting is being performed should also be specified. The distance from the face is important to the effectiveness of ventilation. 4 refs., 3 tabs., 2 figs.

  9. Protection against head injuries should not be optional: a case for mandatory installation of side-curtain air bags.

    Science.gov (United States)

    Stuke, Lance E; Nirula, Raminder; Gentilello, Larry M; Shafi, Shahid

    2010-10-01

    More than 9,000 vehicle occupants die each year in side-impact vehicle collisions, primarily from head injuries. The authors hypothesized that side-curtain air bags significantly improve head and neck safety in side-impact crash testing. Side-impact crash-test data were obtained from the Insurance Institute for Highway Safety, which ranks occupant protection as good, acceptable, marginal, or poor. Vehicles of the same make and model that underwent side-impact crash testing both with and without side-curtain air bags were compared, as well as the protective effect of these air bags on occupants' risk for head and neck injury. Of all the passenger vehicles, 25 models have undergone side-impact crash testing with and without side-curtain air bags by the Insurance Institute for Highway Safety. Only 3 models without side-curtain air bags (12%) provided good head and neck protection for drivers, while 21 cars with side-curtain air bags (84%) provided good protection (P bags was less dramatic but significant (84% without vs 100% with side-curtain air bags, P = .04). Side-curtain air bags significantly improve vehicle occupant safety in side-impact crash tests. Installation of these air bags should be federally mandated in all passenger vehicles. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Science.gov (United States)

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  11. 40 CFR 60.1455 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Science.gov (United States)

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1455 Section 60... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1455 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

  12. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Science.gov (United States)

    2010-07-01

    ... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  13. Orthogonal design on range hood with air curtain and its effects on kitchen environment.

    Science.gov (United States)

    Liu, Xiaomin; Wang, Xing; Xi, Guang

    2014-01-01

    Conventional range hoods cannot effectively prevent the oil fumes containing cooking-induced harmful material from escaping into the kitchen Air curtains and guide plates have been used in range hoods to reduce the escape of airborne emissions and heat, thereby improving the kitchen environment and the cook's degree of comfort. In this article, numerical simulations are used to study the effects of the jet velocity of an air curtain, the jet angle of the air curtain, the width of the jet slot, the area of the guide plate, and the exhaust rate of the range hood on the perceived temperature, the perceived concentration of oil fumes, the release temperature of oil fumes, and the concentration of escaped oil fumes in a kitchen. The orthogonal experiment results show that the exhaust rate of the range hood is the main factor influencing the fumes concentration and the temperature distribution in the kitchen. For the range hood examined in the present study, the optimum values of the exhaust rate, the jet velocity of the air curtain, the jet angle of the air curtain, the width of the jet slot, and the area of the guide plate are 10.5 m(3)/min, 1.5 m/s, -5°, 4 mm, and 0.22 m(2), respectively, based on the results of the parametric study. In addition, the velocity field, temperature field, and oil fumes concentration field in the kitchen using the proposed range hood with the air curtain and guide plate are analyzed for those parameters. The study's results provide significant information needed for improving the kitchen environment.

  14. New options for the cold storage air curtain in the food sector; Koelruimte-luchtgordijn biedt nieuwe mogelijkheden

    Energy Technology Data Exchange (ETDEWEB)

    Bruins, K. [Biddle, Kootstertille (Netherlands)

    1997-10-01

    Based on a newly developed so-called multi air jet technology air curtains in front of cold spaces prevent warm air from infiltrating the cold space. The principles and performance of the cold space air curtain are briefly outlined. 2 figs.

  15. Detailed analysis of turbulent flows in air curtains

    NARCIS (Netherlands)

    Jaramillo, Julian E.; Perez-Segarra, Carlos D.; Lehmkuhl, Oriol; Castro, Jesus

    2011-01-01

    In order to prevent entrainment, an air curtain should provide a jet with low turbulence level, and enough momentum to counteract pressure differences across the opening. Consequently, the analysis of the discharge plenum should be taken into consideration. Hence, the main object of this paper is to

  16. 40 CFR 62.15375 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15375 Section 62.15375 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15375 What are the emission limits for air curtain incinerators that burn 100 percent yard...

  17. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  18. 40 CFR 60.1920 - What are the emission limits for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1920 Section 60.1920 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1920 What are the emission limits for air curtain incinerators that burn 100 percent yard waste? If...

  19. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  20. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  1. 40 CFR 62.15385 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Science.gov (United States)

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 62.15385 Section 62... Incinerators That Burn 100 Percent Yard Waste § 62.15385 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  2. 40 CFR 60.1930 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Science.gov (United States)

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent yard waste? 60.1930 Section 60... Incinerators That Burn 100 Percent Yard Waste § 60.1930 What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100 percent yard waste? (a) Provide a notice of construction...

  3. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Science.gov (United States)

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068...

  4. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or...

  5. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the...

  6. 40 CFR 60.3062 - What is an air curtain incinerator?

    Science.gov (United States)

    2010-07-01

    ... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is... this subpart. (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent yard waste. (4...

  7. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  8. Automatic control of air curtains with CHIPS technology; Automatische regeling van luchtgordijnen met CHIPS-technologie

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, B.E. [Biddle, Kloostertille (Netherlands)

    2010-03-15

    In times of drastic automation air curtains cannot lag behind. Yet, how do you control a product whose operation depends not only on own settings but also on the conditions in which it is used. This article describes the latest development in the automation of the air curtain above an open door. The automated air curtain now has the highest separation efficiency, low energy use and optimal comfort under changing circumstances without any need for manual adjustment. CHIPS refers to Corrective Heating and Impulse Prediction System. [Dutch] In een tijd van verregaande automatisering kan een luchtgordijn niet achterblijven. Maar hoe regel je een product waarvan de werking niet alleen afhangt van de eigen instellingen, maar ook van de omstandigheden waarin het wordt gebruikt? Dit artikel beschrijft de nieuwste stap in de automatisering van een luchtgordijn boven een openstaande deur. Hiermee heeft het automatisch geregelde luchtgordijn het hoogste scheidingsrendement, laag energiegebruik en optimaal comfort onder wisselende omstandigheden zonder het luchtgordijn handmatig te hoeven bijstellen. CHIPS staat voor Corrective Heating and Impulse Prediction System.

  9. Air curtain technology improves working conditions with open hall doors; Luftschleiertechnik verbessert Arbeitsbedingungen bei geoeffneten Hallentoren

    Energy Technology Data Exchange (ETDEWEB)

    Multhauf, R. [Biddle GmbH, Koeln (Germany)

    1998-11-01

    Hall doors are indispensable for short logistic distances of product or raw materials management. Air curtain systems make it possible to keep doors open independent of the weather and season. The heating energy requiremens of modern air curtain systems has been reduced significantly. (orig.) [Deutsch] Hallentore sind fuer moeglichst kurze Logistikwege der Waren oder Rohstoffe im industriellen Betrieb unvermeidlich. Luftschleieranlagen ermoeglichen offene Tore unabhaengig von der Witterung und der Jahreszeit. Die zur Betreibung der Luftschleieranlagen notwendige Heizenergie wurde durch neue Entwicklungen stark reduziert. (orig.)

  10. Retrofit curtain for overhead doors

    Energy Technology Data Exchange (ETDEWEB)

    Leckie, R E

    1987-12-29

    A heat insulating curtain has been developed for reducing heat losses through overhead doors of the type commonly found in industrial warehouses. The curtain consists of a reinforced polyester fabric attached to the outside top of the overhead door and moves with the door as it opens and closes. A T-shaped edge track seals the edges of the curtain to the door frame; the edge of the curtain is also T-shaped and runs up and down the track as the curtain is raised and lowered. The curtain fabric is ultraviolet resistant, durable, flexible, and transparent, and transforms the door into a solar collector which provides solar heated air to the building interior. Two curtains have been satisfactorily installed and tested at a warehouse in Calgary, Alberta. A market evaluation study was conducted to determine the possible buyers for such a door curtain. A target market consisting of those wishing to fix old, leaky doors was selected and a marketing strategy developed. The described strategy includes product development, pricing, distribution, promotion, and advertising. 2 figs., 1 tab.

  11. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Science.gov (United States)

    2010-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain...

  12. Controlling allergens in animal rooms by using curtains

    DEFF Research Database (Denmark)

    Krohn, Thomas Cæcius; Itter, Gabi; Fosse, Richard

    2006-01-01

    The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room. The experimen......The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room....... The experimental situation we studied provides some information regarding allergen disposition in animal rooms but is clearly artificial and does not reflect a typical, ‘real-world’ environment in terms of preventing exposure of workers to allergens. Plastic curtains with holes were placed in front of racks......, and a corridor between the racks and a curtain was present. The room was ventilated with air, which was blown into the room through the middle of the corridor, flowing downstream and passing through the holes in the curtain. This set-up resulted in air flow from the corridor through the curtain. Air samples were...

  13. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Science.gov (United States)

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Compliance Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard...

  14. Optimization of air-curtain sealing efficiency with respect to heat transfer in naturally ventilated buildings

    NARCIS (Netherlands)

    Khayrullina, A.; Hooff, van T.A.J.; Blocken, B.J.E.; van Heijst, G.J.F.; Sun, Y.; Pei, J.; Zhao, X

    This study presents results of coupled 3D steady Reynolds-averaged Navier-Stokes (RANS) Computational Fluid Dynamics (CFD) simulations of an isolated naturally-ventilated building with the application of an air curtain to prevent heat transfer across a doorway. The considered parameters include air

  15. Logistic advantages of an air curtain in a cold store; Heiploeg ervaart logistieke voordelen van vrieshuis-luchtgordijn

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Fog and ice are problems in cold storage warehouses. A manufacturer of air conditioning equipment (Biddle in Kootstertille, Netherlands) claims to have found the solution in the so-called Multi Air stream Technology, an air curtain for cold stores.

  16. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Science.gov (United States)

    2010-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not... Compliance Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60...

  17. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or...

  18. Draught control by means of industrial air curtains. Background information on the design of industrial air curtains; Tochtbestrijding met industriele luchtgordijnen. Achtergronden bij ontwerp van industriele luchtgrodijnen

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, B. [Biddle, Kootstertille (Netherlands); Traversar, R. [TNO Milieu, Energie en Procesinnovatie TNO-MEP, Apeldoorn (Netherlands)

    2008-02-15

    In industrial buildings a balanced ventilation is not common property. Due to increasing differences in pressure across the front much cold outside air enters the building, resulting in poor comfort near the door. A good air curtain can heat up large amounts of incoming cold outside air in such a way that energy saving is optimal and comfort remains high. (mk) [Dutch] Bij industriele gebouwen is gebalanceerde ventilatie geen gemeengoed. Door oplopende drukverschillen over de gevel komt veel koude buitenlucht naar binnen en is het comfort vlak achter de deur erg laag. Een goed luchtgordijn kan grote hoeveelheden binnenkomende koude buitenlucht zodanig opwarmen dat de energiebesparing optimaal is en het comfort hoog blijft.

  19. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for...

  20. Effect of Rheological Properties on Liquid Curtain Coating

    Science.gov (United States)

    Mohammad Karim, Alireza; Suszynski, Wieslaw; Griffith, William; Pujari, Saswati; Carvalho, Marcio; Francis, Lorraine; Dow Chemical Company Collaboration; PUC-Rio Collaboration

    2017-11-01

    Curtain coating is one of the preferred methods for high-speed precision application of single-layer and multi-layer coatings in technology. However, uniform coatings are only obtained in a certain range of operating parameters, called coating window. The two main physical mechanisms that limit successful curtain coating are liquid curtain breakup and air entrainment. The rheological properties of the liquid play an important role on these mechanisms, but the fundamental understanding of these relations is still not complete. The effect of rate-dependent shear and extensional viscosities on the stability of viscoelastic and shear thinning liquid curtains were explored by high-speed visualization. Aqueous solutions of polyethylene oxide (PEO) and polyethylene glycol (PEG) were used as viscoelastic liquids. Xanthan Gum in water and glycerol solutions with a range of compositions were used as shear thinning liquids. The critical condition was determined by examining flow rate below which curtain broke. In this work, we also analyze relative importance of rate-dependent shear and extensional viscosity on both curtain breakup and air entrainment. We would like to acknowledge the financial support from the Dow Chemical Company.

  1. On the use of infrared thermography in studies with air curtain devices

    Energy Technology Data Exchange (ETDEWEB)

    Neto, L. P. C. [Departamento de Engenharia Industrial, Escola Superior de Tecnologia, Instituto Politecnico de Castelo Branco, Castelo Branco (Portugal); Silva, M. C. G.; Costa, J. J. [Departamento de Engenharia Mecanica, Faculdade de Ciencias e Tecnologia da Universidade de Coimbra, Polo II, Coimbra (Portugal)

    2006-07-01

    Among the different existing methods to characterise the aerodynamic sealing effect provided by an air curtain device placed over the opening between two contiguous compartments, infrared thermography has revealed to be a very useful tool. Besides allowing the capture, in an expedite way, of instantaneous images of the temperature field in the neighbourhood of the door, the technique hereon described has other advantages, in terms of quick and easy setup, low intrusive character and liability of obtained results. To apply this method, a large sheet of paper was stretched in the direction perpendicular to the opening where the air curtain device has placed to allow the registration of pictures or video sequences with an infrared camera setup in its maximum sensitivity. Good concordance between the thermographs obtained with this technique and the temperature fields measured for the same plane with a rack of 16 low velocity omni-directional thermal anemometer probes allowed its validation. Various elucidative examples of the use of this technique as a complementary tool for analysis and visualization of the complex physical phenomena occurring for the studied flow are presented in this article. (author)

  2. Comparison of heat transfer and soil impacts of air curtain burner burning and slash pile burning

    Science.gov (United States)

    Woongsoon Jang; Deborah S. Page-Dumroese; Han-Sup Han

    2017-01-01

    We measured soil heating and subsequent changes in soil properties between two forest residue disposal methods: slash pile burning (SPB) and air curtain burner (ACB). The ACB consumes fuels more efficiently and safely via blowing air into a burning container. Five burning trials with different fuel sizes were implemented in northern California, USA. Soil temperature...

  3. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What...

  4. On the use of infrared thermography in studies with air curtain devices

    OpenAIRE

    Neto, Luís P. C.; Silva, Manuel Gameiro da; Costa, José J.

    2006-01-01

    Among the different existing methods to characterise the aerodynamic sealing effect provided by an air curtain device placed over the opening between two contiguous compartments, infrared thermography has revealed to be a very useful tool. Besides allowing the capture, in an expedite way, of instantaneous images of the temperature field in the neighbourhood of the door, the technique hereon described has other advantages, in terms of quick and easy setup, low intrusive character and liability ...

  5. Blow capacity of an air curtain; Hoe hard denkt u dat een luchtgrodijn moet blazen?

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, B.E. [Biddle, Kootstertille (Netherlands)

    2003-03-01

    In winter, the heat capacity of a conventional air curtain can often be increased by adjusting the speed of its outlet velocity. This article demonstrates that for various reasons, it is better to adjust the width of the outlet if you need to boost the heat level rather than the outlet velocity. It also describes the benefits of this CA (Constant Air Velocity) Technology in the interests of energy conservation and comfort. [Dutch] In de winter wordt de warmtecapaciteit van een conventioneel luchtgordijn vaak verhoogd door de uitblaassnelheid aan te passen. Dit artikel toont aan dat het om meerdere redenen beter is om bij een hogere warmtebehoefte de uitblaasbreedte aan te passen in plaats van de uitblaassnelheid. Daarnaast beschrijft het de voordelen van deze CA-technologie (Constant Air velocity) wat betreft energieverbruik en comfort.

  6. Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions

    International Nuclear Information System (INIS)

    Gaspar, Pedro Dinis; Carrilho Goncalves, L.C.; Pitarma, R.A.

    2011-01-01

    The vertical open refrigerated display cabinets suffer alterations of their thermal performance and energy efficiency due to variations of ambient air conditions. The air curtain provides an aerothermodynamics insulation effect that can be evaluated by the thermal entrainment factor calculation as an engineering approximation or by the calculus of all sensible and latent thermal loads. This study presents the variation of heat transfer rate and thermal entrainment factor obtained through experimental tests carried out for different ambient air conditions, varying air temperature, relative humidity, velocity and its direction relatively to the display cabinet frontal opening. The thermal entrainment factor are analysed and compared with the total sensible and latent heats results for the experimental tests. From an engineering point of view, it is concluded that thermal entrainment factor cannot be used indiscriminately, although its use is suitable to design better cabinet under the same climate class condition.

  7. The use of an air curtain in a cold store; Vrieshuis toegankelijker en veiliger met luchtscherm

    Energy Technology Data Exchange (ETDEWEB)

    Bruins, K. [Biddle, Kootstertille (Netherlands)

    1998-04-01

    A food distribution centre of a German chain of supermarkets applies an air curtain in one of their distribution centres (Neudietendorf, Erfurt). The door of the distribution centre building can be left open constantly which improves internal transport of the goods (next to dry products also many frozen products). Even more important is that ice forming in the passage is reduced to a minimum and the safety for the workers has improved considerably

  8. Experimental data and boundary conditions for a Double-Skin Facade building in external air curtain mode

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Heiselberg, Per; Jensen, Rasmus Lund

    Frequent discussions of double skin façade energy performance have started a dialogue about the methods, models and tools for simulation of double façade systems and reliability of their results. Their reliability will increase with empirical validation of the software. Detailed experimental work...... was carried out in a full scale test facility ‘The Cube’, in order to compile three sets of high quality experimental data for validation purposes. The data sets are available for preheating mode, external air curtain mode and transparent insulation mode. The objective of this article is to provide the reader......’. This covers such problem areas as measurements of naturally induced air flow, measurements of air temperature under direct solar radiation exposure, etc. Finally, in order to create a solid foundation for software validation, the uncertainty and limitations in the experimental results are discussed. In part...

  9. Radiation shielding curtain

    International Nuclear Information System (INIS)

    Winkler, N.T.

    1976-01-01

    A radiation shield is described in the form of a stranded curtain made up of bead-chains whose material and geometry are selected to produce a cross-sectional density that is the equivalent of 0.25 mm or more of lead and which curtain may be mounted on various radiological devices to shield against scattered radiation while offering a minimum of obstruction to the radiologist

  10. Effect of Viscosity on Liquid Curtain Stability

    Science.gov (United States)

    Mohammad Karim, Alireza; Suszynski, Wieslaw; Francis, Lorraine; Carvalho, Marcio; Dow Chemical Company Collaboration; PUC Rio Collaboration; University of Minnesota, Twin Cities Collaboration

    2016-11-01

    The effect of viscosity on the stability of Newtonian liquid curtains was explored by high-speed visualization. Glycerol/water solutions with viscosity ranging from 19.1 to 210 mPa.s were used as coating liquids. The experimental set-up used a slide die delivery and steel tube edge guides. The velocity along curtain at different positions was measured by tracking small particles at different flow conditions. The measurements revealed that away from edge guides, velocity is well described by free fall effect. However, close to edge guides, liquid moves slower, revealing formation of a viscous boundary layer. The size of boundary layer and velocity near edge guides are strong function of viscosity. The critical condition was determined by examining flow rate below which curtain broke. Curtain failure was initiated by growth of a hole within liquid curtain, close to edge guides. Visualization results showed that the hole forms in a circular shape then becomes elliptical as it grows faster in vertical direction compared to horizontal direction. As viscosity rises, minimum flow rate for destabilization of curtain increased, indicating connection between interaction with edge guides and curtain stability. We would like to acknowledge the financial support from the Dow Chemical Company.

  11. Overview of fire curtains in construction

    Directory of Open Access Journals (Sweden)

    Nedryshkin Oleg

    2016-01-01

    Full Text Available A fire curtain is use where, if there is a fire, it is necessary to create a temporary barrier within an opening, which seals off the area on fire. The curtain descends and prevents any fire and smoke from spreading from one area to another. It also allows people access to protected escape routes without any loss of fire resistance. The paper aims to presents the results of analysis of the scientific literature on the subject of fire curtains.

  12. Curtain color and lighting program in broiler production: III - thermal comfort

    Directory of Open Access Journals (Sweden)

    Paulo Giovanni de Abreu

    2011-09-01

    Full Text Available The objective of this study was to evaluate the thermal comfort of broilers reared under two lighting programs (almost continuous and intermittent in broiler houses with yellow or blue lateral curtains. The experiment was carried out from June 24, 2004 until May 12, 2005. Six consecutive flocks were housed in four 12 × 10 m broilers houses internally divided into four pens of 200 birds each. Six flocks were raised on the same litter. The registration of data was accomplished at 3-hour intervals, for 24 hours twice a week. In the center of each pen and outside the house, dry and wet bulb temperatures, black globe temperature, and air velocity were collected. Based on the data collected at each time, air temperature (AT (ºC, black globe humidity temperature index (BGHTI, radiant thermal load (RTL (W/m², and relative air humidity (RH were determined. Harmonic analysis was used to estimate m, R, and f parameters. In general, the best results in terms of thermal comfort for the birds were found when near-continuous lighting program and yellow curtain were used.

  13. Blast Analysis of Laminated Glass Curtain Walls Equipped by Viscoelastic Dissipative Devices

    Directory of Open Access Journals (Sweden)

    Chiara Bedon

    2012-09-01

    Full Text Available Nonlinear numerical simulations are reported for a conventional unitized laminated glass curtain wall subjected to high- and low-level air blast loading. The studied curtain wall, spanning floor to floor, consisted of a laminated glass panel, a continuous bead of structural silicone sealant, a split screw spline frame and four rigid brackets. Firstly, a linear elastic FE-model (M01 is presented to investigate dynamic stresses and deflections due to explosion, by taking into account geometrical nonlinearities. Since, in similar glazing systems, it is important to take into account the possible cracking of glass lites, a second model (M02, calibrated to previous experimental data, is proposed. In it, glass behaves as a brittle-elastic material, whereas an elastoplastic characteristic curve is assumed for mullions. As a result, the design explosion seriously affects the main components of the curtain wall, especially the bead of silicone. To address these criticalities, additional viscoelastic (VE devices are installed at the frame corners (M03. Their effectiveness explains the additional deformability provided to the conventional curtain wall, as well as the obvious dissipation of the incoming energy due to blast loading. Structural and energy capabilities provided by devices are highlighted by means of numerical simulations.

  14. Solar collector wall with active curtain system; Lasikatteinen massiivienen aurinkokeraeaejaeseinae

    Energy Technology Data Exchange (ETDEWEB)

    Ojanen, T.; Heimonen, I. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1998-12-01

    Integration of solar collector into the building envelope structure brings many advantages. The disadvantage of a passive solar collector wall is that its thermal performance can not be controlled, which may cause temporary overheating and low thermal efficiency of the collector. The thermal performance of the collector wall can be improved by using controllable, active collector systems. In this paper a solar collector wall with a controllable curtain between the transparent and absorption layers is investigated. The curtain is made of several low-emissivity foil layers, which ensures low radiation heat transfer through the curtain. The curtain decreases the heat losses out from the collector wall and it improves the U-value of the wall. The curtain is used when the solar radiation intensity to the wall is not high enough or when the wall needs protection against overheating during warm weather conditions. The materials and building components used in the collector wall, except those of the curtain, are ordinary in buildings. The transparent layer can be made by using normal glazing technology and the thermal storage layer can be made out of brick or similar material. The solar energy gains through the glazing can be utilised better than in passive systems, because the curtain provides the wall with high thermal resistance outside the solar radiation periods. The thermal performance of the collector wall was studied experimentally using a Hot-Box apparatus equipped with a solar lamp. Numerical simulations were carried out to study the yearly performance of the collector wall under real climate conditions. The objectives were to determine the thermal performance of the collector wall and to study how to optimise the use of solar radiation in this system. When the curtain with high thermal resistance is used actively, the temperature level of the thermal storage layer in the wall is relatively high also during dark periods and the heat losses out from the storage

  15. Drawing the Curtain on Enceladus' South-Polar Eruptions

    Science.gov (United States)

    Spitale, Joseph N.; Hurford, Terry A.; Rhoden, Alyssa R.; Berkson, Emily E.; Platts, Symeon S.

    2015-11-01

    For a comprehensive description of Enceladus' south-polar eruptions observed at high resolution, they must be represented as broad curtains rather than discrete jets. Meanders in the fractures from which the curtains of material erupt give rise to optical illusions that look like discrete jets, even along fractures with no local variations in eruptive activity, implying that many features previously identified as "jets" are in fact phantoms. By comparing Cassini images with model curtain eruptions, we are able to obtain maps of eruptive activity that are not biased by the presence of those phantom jets. The average of our activity maps over all times agrees well with thermal maps produced by Cassini CIRS. We can best explain the observed curtains by assuming spreading angles with altitude of up to 14° and zenith angles of up to 8°, for curtains observed in geometries that are sensitive to those quantities.

  16. Experimental investigation of hysteresis in the break-up of liquid curtains

    KAUST Repository

    Marston, Jeremy

    2014-09-01

    Findings from an experimental investigation of the break-up of liquid curtains are reported, with the overall aim of examining stability windows for multi-layer liquid curtains composed of Newtonian fluids, where the properties of each layer can be kept constant or varied. For a single-layer curtain it is known that the minimum flow rate required for initial stability can be violated by carefully reducing the flow rate below this point, which defines a hysteresis region. However, when two or three layers are used to form a composite curtain, the hysteresis window can be considerably reduced depending on the experimental procedure used. Extensive quantitative measurements of this hysteresis region are provided alongside an examination of the influence of physical properties such as viscosity and surface tension. The origins of curtain break-up for two different geometries are analysed; first where the curtain width remains constant, pinned by straight edge guides; and second where the curtain is tapered by angled edge guides. For both cases, the rupture speed is measured, which appears to be consistent with the Taylor-Culick velocity. Observations of the typical linearly spaced jets which form after the break-up has transpired and the periodicity of these jets are compared to the Rayleigh-Taylor wavelength and previous experimental measurements. Furthermore, the curtain stability criterion originally developed by Brown (1961), summarised in terms of a Weber number, has recently been extended to multi-layer curtains by Dyson et al. (2009); thus this report provides the first experimental measurements which puts this to the test. Ultimately, it is found that only the most viscous and polymer-based liquids violate this criterion. © 2014 Elsevier Ltd.

  17. Water curtain

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Fedotov, I.N.; Prokopov, O.I.

    1982-01-01

    The patented water curtain is used to eliminate gas-oil gushers and is distinguished by the fact that in order to simplify operation, the water-line collector is made out of two symmetrical parts installed with the possibility of relative rotation. The collector is equipped with at least one pipe arranged in the zone of the collector and has openings for the supply of water.

  18. Stability of an unsupported multi-layer surfactant laden liquid curtain under gravity

    KAUST Repository

    Henry, D.

    2015-11-07

    The industrial process of curtain coating has long been an important method in coating applications, by which a thin liquid curtain is formed to impinge upon a moving substrate, due to its highly lucrative advantage of being able to coat multiple layers simultaneously. We investigate the linear stability of an unsupported two-layer liquid curtain, which has insoluble surfactants in both liquids, which are widely used in industry to increase the stability of the curtain. We formulate the governing equations, simplified by making a thin film approximation, from which we obtain equations describing the steady-state profiles. We then examine the response of the curtain to small perturbations about this steady state to identify conditions under which the curtain is unstable, finding the addition of surfactants stabilizes the curtain. Our results are then compared to experimental data, showing a favourable trend and thereby extending the works of Brown (J Fluid Mech 10:297–305, 1960) and Dyson et al. (J Eng Math 64:237–250, 2009).

  19. Acoustic assessment of speech privacy curtains in two nursing units

    Science.gov (United States)

    Pope, Diana S.; Miller-Klein, Erik T.

    2016-01-01

    Hospitals have complex soundscapes that create challenges to patient care. Extraneous noise and high reverberation rates impair speech intelligibility, which leads to raised voices. In an unintended spiral, the increasing noise may result in diminished speech privacy, as people speak loudly to be heard over the din. The products available to improve hospital soundscapes include construction materials that absorb sound (acoustic ceiling tiles, carpet, wall insulation) and reduce reverberation rates. Enhanced privacy curtains are now available and offer potential for a relatively simple way to improve speech privacy and speech intelligibility by absorbing sound at the hospital patient's bedside. Acoustic assessments were performed over 2 days on two nursing units with a similar design in the same hospital. One unit was built with the 1970s’ standard hospital construction and the other was newly refurbished (2013) with sound-absorbing features. In addition, we determined the effect of an enhanced privacy curtain versus standard privacy curtains using acoustic measures of speech privacy and speech intelligibility indexes. Privacy curtains provided auditory protection for the patients. In general, that protection was increased by the use of enhanced privacy curtains. On an average, the enhanced curtain improved sound absorption from 20% to 30%; however, there was considerable variability, depending on the configuration of the rooms tested. Enhanced privacy curtains provide measureable improvement to the acoustics of patient rooms but cannot overcome larger acoustic design issues. To shorten reverberation time, additional absorption, and compact and more fragmented nursing unit floor plate shapes should be considered. PMID:26780959

  20. Acoustic assessment of speech privacy curtains in two nursing units.

    Science.gov (United States)

    Pope, Diana S; Miller-Klein, Erik T

    2016-01-01

    Hospitals have complex soundscapes that create challenges to patient care. Extraneous noise and high reverberation rates impair speech intelligibility, which leads to raised voices. In an unintended spiral, the increasing noise may result in diminished speech privacy, as people speak loudly to be heard over the din. The products available to improve hospital soundscapes include construction materials that absorb sound (acoustic ceiling tiles, carpet, wall insulation) and reduce reverberation rates. Enhanced privacy curtains are now available and offer potential for a relatively simple way to improve speech privacy and speech intelligibility by absorbing sound at the hospital patient's bedside. Acoustic assessments were performed over 2 days on two nursing units with a similar design in the same hospital. One unit was built with the 1970s' standard hospital construction and the other was newly refurbished (2013) with sound-absorbing features. In addition, we determined the effect of an enhanced privacy curtain versus standard privacy curtains using acoustic measures of speech privacy and speech intelligibility indexes. Privacy curtains provided auditory protection for the patients. In general, that protection was increased by the use of enhanced privacy curtains. On an average, the enhanced curtain improved sound absorption from 20% to 30%; however, there was considerable variability, depending on the configuration of the rooms tested. Enhanced privacy curtains provide measureable improvement to the acoustics of patient rooms but cannot overcome larger acoustic design issues. To shorten reverberation time, additional absorption, and compact and more fragmented nursing unit floor plate shapes should be considered.

  1. Acoustic assessment of speech privacy curtains in two nursing units

    Directory of Open Access Journals (Sweden)

    Diana S Pope

    2016-01-01

    Full Text Available Hospitals have complex soundscapes that create challenges to patient care. Extraneous noise and high reverberation rates impair speech intelligibility, which leads to raised voices. In an unintended spiral, the increasing noise may result in diminished speech privacy, as people speak loudly to be heard over the din. The products available to improve hospital soundscapes include construction materials that absorb sound (acoustic ceiling tiles, carpet, wall insulation and reduce reverberation rates. Enhanced privacy curtains are now available and offer potential for a relatively simple way to improve speech privacy and speech intelligibility by absorbing sound at the hospital patient′s bedside. Acoustic assessments were performed over 2 days on two nursing units with a similar design in the same hospital. One unit was built with the 1970s′ standard hospital construction and the other was newly refurbished (2013 with sound-absorbing features. In addition, we determined the effect of an enhanced privacy curtain versus standard privacy curtains using acoustic measures of speech privacy and speech intelligibility indexes. Privacy curtains provided auditory protection for the patients. In general, that protection was increased by the use of enhanced privacy curtains. On an average, the enhanced curtain improved sound absorption from 20% to 30%; however, there was considerable variability, depending on the configuration of the rooms tested. Enhanced privacy curtains provide measureable improvement to the acoustics of patient rooms but cannot overcome larger acoustic design issues. To shorten reverberation time, additional absorption, and compact and more fragmented nursing unit floor plate shapes should be considered.

  2. Emissions from the burning of vegetative debris in air curtain destructors.

    Science.gov (United States)

    Miller, C Andrew; Lemieux, Paul M

    2007-08-01

    Although air curtain destructors (ACDs) have been used for quite some time to dispose of vegetative debris, relatively little in-depth testing has been conducted to quantify emissions of pollutants other than CO and particulate matter. As part of an effort to prepare for possible use of ACDs to dispose of the enormous volumes of debris generated by Hurricanes Katrina and Rita, the literature on ACD emissions was reviewed to identify potential environmental issues associated with ACD disposal of construction and demolition (C&D) debris. Although no data have been published on emissions from C&D debris combustion in an ACD, a few studies provided information on emissions from the combustion of vegetative debris. These studies are reviewed, and the results compared with studies of open burning of biomass. Combustion of vegetative debris in ACD units results in significantly lower emissions of particulate matter and CO per unit of mass of debris compared with open pile burning. The available data are not sufficient to make general estimates regarding emissions of organic or metal compounds. The highly transient nature of the ACD combustion process, a minimal degree of operational control, and significant variability in debris properties make accurate prediction of ACD emissions impossible in general. Results of scoping tests conducted in preparation for possible in-depth emissions tests demonstrate the challenges associated with sampling ACD emissions and highlight the transient nature of the process. The environmental impacts of widespread use of ACDs for disposal of vegetative debris and their potential use to reduce the volume of C&D debris in future disaster response scenarios remain a considerable gap in understanding the risks associated with debris disposal options.

  3. Special solution with air curtain to guarantee a draft-free environment; Speciale oplossing met luchtgordijn waarborgt tochtvrije omgeving

    Energy Technology Data Exchange (ETDEWEB)

    Attema, A. [Biddle, Kootstertille (Netherlands)

    2002-01-01

    The impact of air curtains in the luggage dispatch facility of the Dutch airport Schiphol on the working conditions is discussed. [Dutch] Om het klimaat in een grote ruimte op een aangenaam niveau te houden, zoeken werkgevers vaak naar een oplossing, waarbij de luchtstromen in die ruimte voor de werknemers aanvaardbaar zijn. Vooral voor een gebouw dat onderhevig is aan sterke windaanvallen dient de oplossing met grote zorgvuldigheid te worden gekozen. De bagageruimte op de D-pier van luchthaven Schiphol staat op een plaats met ongunstige windstromingen. De vier openingen in de bagageruimte, waar bagagewagentjes in en uitrijden, zijn om die reden voorzien van industrie-luchtgordijnen. Per deur is gekozen voor een oplossing met ongeveer tien toestellen, die in drie rijen achter elkaar zijn geinstalleerd. Afhankelijk van de buiten emperatuur en de windinvloed worden de ventilatoren trapsgewijze ingeschakeld, zodra de pendeldeuren open gaan. De luchtgordijnen laten een onbelemmerde toegang tot de bagageruinite toe en realiseren een optimale scheiding van bet binnen- en buitenklimaat.

  4. Electrical characteristics and influence of the air-gap size in a trielectrode plasma curtain at atmospheric pressure

    International Nuclear Information System (INIS)

    Sosa, R; Artana, G; Grondona, D; Marquez, A; Kelly, H

    2009-01-01

    A study of the electrical characteristics of the trielectrode plasma curtain (TPC) discharge is presented. The influence of the air-gap size (for a fixed value of the inter-electrode distance) on the discharge behaviour has been exhaustively studied. The TPC discharge is based on the combination of a dielectric barrier discharge (DBD) with a corona discharge (CD) in a three electrode system, and basically it consists of the 'stretching' of a pure DBD by the action of a negative CD generated between the active electrode of the dielectric barrier and a remote third electrode. It was found that the general trend of the electrical characteristic curves (the average discharge current and the streamer frequency as functions of the AC and DC biasing voltages) was very similar for all the air-gap values considered. Our results indicate that the development of the TPC discharge requires two conditions: (a) the presence of a positive cycle of a well-developed DBD together with a CD where the remote electrode acts as the cathode and (b) a voltage drop between the DBD electrode and the remote electrode high enough to obtain an average electric field in the gap that must exceed a minimum average electric field value in the streamer channel necessary for its propagation across the gap (∼6.3 kV cm -1 in our experimental conditions).

  5. Timber Curtain

    DEFF Research Database (Denmark)

    2015-01-01

    Timber Curtain is a site specific architectural installation, which is part of a research project conducted at the Aarhus School of Architecture as collaboration between Ph.D. and associate professor Niels Martin Larsen and the author. Through a digitally scripted associative model we performed s...... of pinewood timber, machined with a CMS Antares 5-axis CNC router. The digital process generation and simulation was implemented with Rhinoceros 3D, Grasshopper and GHPython, and AlphaCAM was used for preparing the CNC-routing....

  6. On radiative transfer in water spray curtains using the discrete ordinates method

    Energy Technology Data Exchange (ETDEWEB)

    Collin, A. [Laboratoire d' Energetique et de Mecanique Theorique and Appliquee (LEMTA), CNRS UMR 7563, Faculte des Sciences et Techniques BP 239 - 54506 VANDOEUVRE Cedex (France); Boulet, P. [Laboratoire d' Energetique et de Mecanique Theorique and Appliquee (LEMTA), CNRS UMR 7563, Faculte des Sciences et Techniques BP 239 - 54506 VANDOEUVRE Cedex (France)]. E-mail: Pascal.Boulet@lemta.uhp-nancy.fr; Lacroix, D. [Laboratoire d' Energetique et de Mecanique Theorique and Appliquee (LEMTA), CNRS UMR 7563, Faculte des Sciences et Techniques BP 239 - 54506 VANDOEUVRE Cedex (France); Jeandel, G. [Laboratoire d' Energetique et de Mecanique Theorique and Appliquee (LEMTA), CNRS UMR 7563, Faculte des Sciences et Techniques BP 239 - 54506 VANDOEUVRE Cedex (France)

    2005-04-15

    Radiative transfer through water spray curtains has been presently addressed in conditions similar to devices used in fire protection systems. The radiation propagation from the heat source through the medium is simulated using a 2D Discrete Ordinates Method. The curtain is treated as an absorbing and anisotropically scattering medium, made of droplets injected in a mixing of air, water vapor and carbon dioxide. Such a participating medium requires a careful treatment of its spectral response in order to model the radiative transfer accurately. This particular problem is dealt with using a correlated-K method. Radiative properties for the droplets are calculated applying the Mie theory. Transmissivities under realistic conditions are then simulated after a validation thanks to comparisons with some experimental data available in the literature. Owing to promising results which are already observed in this case of uncoupled radiative problem, next step will be to combine the present study with a companion work dedicated to the careful treatment of the spray dynamics and of the induced heat transfer phenomena.

  7. Microbiological contamination of cubicle curtains in an out-patient podiatry clinic

    Directory of Open Access Journals (Sweden)

    O'Neil Bill

    2010-11-01

    Full Text Available Abstract Background Exposure to potential pathogens on contaminated healthcare garments and curtains can occur through direct or indirect contact. This study aimed to identify the microorganisms present on podiatry clinic curtains and measure the contamination pre and post a standard hospital laundry process. Method Baseline swabs were taken to determine colony counts present on cubical curtains before laundering. Curtains were swabbed again immediately after, one and three weeks post laundering. Total colony counts were calculated and compared to baseline, with identification of micro-organisms. Results Total colony counts increased very slightly by 3% immediately after laundry, which was not statistically significant, and declined significantly (p = 0.0002 by 56% one-week post laundry. Three weeks post laundry colony counts had increased by 16%; although clinically relevant, this was not statistically significant. The two most frequent microorganisms present throughout were Coagulase Negative Staphylococcus and Micrococcus species. Laundering was not completely effective, as both species demonstrated no significant change following laundry. Conclusion This work suggests current laundry procedures may not be 100% effective in killing all microorganisms found on curtains, although a delayed decrease in total colony counts was evident. Cubicle curtains may act as a reservoir for microorganisms creating potential for cross contamination. This highlights the need for additional cleaning methods to decrease the risk of cross infection and the importance of maintaining good hand hygiene.

  8. Simultaneous density-field visualization and PIV of a shock-accelerated gas curtain

    Energy Technology Data Exchange (ETDEWEB)

    Prestridge, K.; Rightley, P.M.; Vorobieff, P. [Los Alamos Nat. Lab., NM (United States). Dynamic Exp. Div.; Benjamin, R.F.; Kurnit, N.A.

    2000-10-01

    We describe a highly-detailed experimental characterization of the Richtmyer-Meshkov instability (the impulsively driven Rayleigh-Taylor instability) (Meshkov 1969; Richtmyer 1960). In our experiment, a vertical curtain of heavy gas (SF{sub 6}) flows into the test section of an air-filled, horizontal shock tube. The instability evolves after a Mach 1.2 shock passes through the curtain. For visualization, we pre-mix the SF{sub 6} with a small ({proportional_to}10{sup -5}) volume fraction of sub-micron-sized glycol/water droplets. A horizontal section of the flow is illuminated by a light sheet produced by a combination of a customized, burst-mode Nd:YAG laser and a commercial pulsed laser. Three CCD cameras are employed in visualization. The ''dynamic imaging camera'' images the entire test section, but does not detect the individual droplets. It produces a sequence of instantaneous images of local droplet concentration, which in the post-shock flow is proportional to density. The gas curtain is convected out of the test section about 1 ms after the shock passes through the curtain. A second camera images the initial conditions with high resolution, since the initial conditions vary from test to test. The third camera, ''PIV camera,'' has a spatial resolution sufficient to detect the individual droplets in the light sheet. Images from this camera are interrogated using particle image velocimetry (PIV) to recover instantaneous snapshots of the velocity field in a small (19 x 14 mm) field of view. The fidelity of the flow-seeding technique for density-field acquisition and the reliability of the PIV technique are both quantified in this paper. In combination with wide-field density data, PIV measurements give us additional physical insight into the evolution of the Richtmyer-Meshkov instability in a problem which serves as an excellent test case for general transition-to-turbulence studies. (orig.)

  9. AA, radiation shielding curtain along the target area

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    At the far left is the beam tube for the high-intensity proton beam from the 26 GeV PS. The tube ends in a thin window and the proton beam continues in air through a hole in the shielding blocks (see also 8010308), behind which the target (see 7905091, 7905094)was located. After the target followed the magnetic horn, focusing the antiprotons, and the first part of the injection line with a proton dump. The antiprotons, deflected by a magnet, left the target area through another shielding wall, to make their way to the AA ring. Laterally, this sequence of components was shielded with movable, suspended, concrete blocks: the "curtain". Balasz Szeless, who had constructed it, is standing at its side.

  10. Design, construction and performance of the Oldman River Dam grout curtain

    Energy Technology Data Exchange (ETDEWEB)

    Hartmaier, H.; Davachi, M. [Acres International Ltd., Calgary, AB (Canada); Dharmawardene, W. [Alberta Environment, Edmonton, AB (Canada); Sinclair, B. [Acres International Ltd., Niagara Falls, ON (Canada)

    2002-07-01

    The 76 m high Oldman River Dam was constructed between 1986 and 1991 near Pincher Creek, Alberta to provide flow regulation and on-stream storage of water for multi-purpose use and irrigation services as well as hydroelectric development. The dam's main structure includes an earth- and rockfill dam, a low earthfill dyke 1500 m long, twin diversion/low level outlet tunnels, a gated spillways structure, and 2 drainage tunnels. A 1.3 km long, three-line grout curtain up to 100 m deep extends below the foundation of the dam and spillway. The grout curtain was built in undeformed Paleocene sedimentary rocks affected by stress relief due to river valley erosion. 80 per cent of the grout consumption was from bedrock structural features. Piezometers, slope indicators and flow measurement weirs were installed in the dam and abutment areas both during and after construction to monitor the performance of the grout curtain. Instrument readings indicate that the grout curtain is successfully preventing the transmission of reservoir pressures to the foundation beneath the downstream shell of the dam. The piezometric pressures downstream of the grout curtain are the same as they were in the foundation before impounding. A small amount of seepage has appeared at the end of the grout curtain at the eastern end of the abutment of the spillway but it is not considered to be significant. 3 refs., 4 figs.

  11. Experimental investigation of hysteresis in the break-up of liquid curtains

    KAUST Repository

    Marston, Jeremy; Thoroddsen, Sigurdur T; Thompson, John W.; Blyth, Mark G.; Henry, Daniel; Uddin, Jamal

    2014-01-01

    Findings from an experimental investigation of the break-up of liquid curtains are reported, with the overall aim of examining stability windows for multi-layer liquid curtains composed of Newtonian fluids, where the properties of each layer can

  12. Design of automatic curtain controlled by wireless based on single chip 51 microcomputer

    Science.gov (United States)

    Han, Dafeng; Chen, Xiaoning

    2017-08-01

    In order to realize the wireless control of the domestic intelligent curtains, a set of wireless intelligent curtain control system based on 51 single chip microcomputer have been designed in this paper. The intelligent curtain can work in the manual mode, automatic mode and sleep mode and can be carried out by the button and mobile phone APP mode loop switch. Through the photosensitive resistance module and human pyroelectric infrared sensor to collect the indoor light value and the data whether there is the person in the room, and then after single chip processing, the motor drive module is controlled to realize the positive inversion of the asynchronous motor, the intelligent opening and closing of the curtain have been realized. The operation of the motor can be stopped under the action of the switch and the curtain opening and closing and timing switch can be controlled through the keys and mobile phone APP. The optical fiber intensity, working mode, curtain state and system time are displayed by LCD1602. The system has a high reliability and security under practical testing and with the popularity and development of smart home, the design has broad market prospects.

  13. Flash X-ray measurements on the shock-induced dispersal of a dense particle curtain

    Science.gov (United States)

    Wagner, Justin L.; Kearney, Sean P.; Beresh, Steven J.; DeMauro, Edward P.; Pruett, Brian O.

    2015-12-01

    The interaction of a Mach 1.67 shock wave with a dense particle curtain is quantified using flash radiography. These new data provide a view of particle transport inside a compressible, dense gas-solid flow of high optical opacity. The curtain, composed of 115-µm glass spheres, initially spans 87 % of the test section width and has a streamwise thickness of about 2 mm. Radiograph intensities are converted to particle volume fraction distributions using the Beer-Lambert law. The mass in the particle curtain, as determined from the X-ray data, is in reasonable agreement with that given from a simpler method using a load cell and particle imaging. Following shock impingement, the curtain propagates downstream and the peak volume fraction decreases from about 23 to about 4 % over a time of 340 µs. The propagation occurs asymmetrically, with the downstream side of the particle curtain experiencing a greater volume fraction gradient than the upstream side, attributable to the dependence of particle drag on volume fraction. Bulk particle transport is quantified from the time-dependent center of mass of the curtain. The bulk acceleration of the curtain is shown to be greater than that predicted for a single 115-µm particle in a Mach 1.67 shock-induced flow.

  14. The cost of routine Aedes aegypti control and of insecticide-treated curtain implementation.

    Science.gov (United States)

    Baly, Alberto; Flessa, Steffen; Cote, Marilys; Thiramanus, Thirapong; Vanlerberghe, Veerle; Villegas, Elci; Jirarojwatana, Somchai; Van der Stuyft, Patrick

    2011-05-01

    Insecticide-treated curtains (ITCs) are promoted for controlling the Dengue vector Aedes aegypti. We assessed the cost of the routine Aedes control program (RACP) and the cost of ITC implementation through the RACP and health committees in Venezuela and through health volunteers in Thailand. The yearly cost of the RACP per household amounted to US$2.14 and $1.89, respectively. The ITC implementation cost over three times more, depending on the channel used. In Venezuela the RACP was the most efficient implementation-channel. It spent US$1.90 (95% confidence interval [CI]: 1.83; 1.97) per curtain distributed, of which 76.9% for the curtain itself. Implementation by health committees cost significantly (P = 0.02) more: US$2.32 (95% CI: 1.93; 2.61) of which 63% for the curtain. For ITC implementation to be at least as cost-effective as the RACP, at equal effectiveness and actual ITC prices, the attained curtain coverage and the adulticiding effect should last for 3 years.

  15. Timber Curtain: Designing with material capabilities

    DEFF Research Database (Denmark)

    Lahmy, Maya; Larsen, Niels Martin

    2015-01-01

    of the generative phase to fabrication of the artefact. Brought together by various conceptual and structural elements the Timber Curtain forms a 4.5 x 2.5 x 0.5 m construct of assembled wood components, digitally crafted through advanced production techniques. Concerned with materiality and processing of the wood......Timber Curtain explores relations between digital precision and material indeterminacy. It is an installation engaging spatially through its presence as a 1:1 architectural component as well as it is exploring novel technologies in the architectural design process from the very beginning...... an associative digital model that could gather and compute in put from material behaviour and out put manufacturing data was scripted. This method enables material capacity to be pushed to the limit of its performance allowing novel sensuous and structural qualities to emerge. The method is developed with use...

  16. Improving the performance of infrared reflective night curtains for warming field plots

    DEFF Research Database (Denmark)

    Bruhn, Dan; Larsen, Klaus S.; de Dato, Giovanbattista D.

    2013-01-01

    Infrared reflective (IR) curtains have been widely used to obtain passive nighttime warming in field ecosystem experiments in order to simulate and study climate warming effects on ecosystems. For any field installation with IR-reflective curtains in an ecosystem the achieved heating effect depen...

  17. A Cost–Benefit Analysis to Assess the Effectiveness of Frontal Center Curtain Airbag

    Directory of Open Access Journals (Sweden)

    Bo Kyeong Lee

    2017-09-01

    Full Text Available Several new varieties of airbags are under consideration for development. However, their commercialization decision must be backed by a positive Cost–Benefit Analysis (CBA outcome. In this study, we propose a CBA framework for the frontal center curtain airbag, a newly designed safety system intended to reduce the injury risk of rear-seat passengers. The proposed CBA covers not only economic benefits of the producer but also the effectiveness in sustainable reduction of the fatal and injury rate. In this context, with accumulated field data on road traffic accidents, a forecasting method reflecting the reduced casualties and the market share of vehicle sales associated with frontal center curtain airbag is utilized. Our results suggest that the use of frontal center curtain airbags helps to reduce the number of casualties with a Maximum Abbreviated Injury Scale (MAIS of 3 or above by 87.4%. Furthermore, both the initial market penetration rate and price of the frontal center curtain airbag significantly influence its socioeconomic benefits. By evaluating the effectiveness of the frontal center curtain airbag, our study can contribute to the decision making for its commercialization.

  18. Curtain Antenna Array Simulation Research Based on MATLAB

    Directory of Open Access Journals (Sweden)

    Hongbo LIU

    2014-01-01

    Full Text Available For the radiating capacity of curtain antenna array, this paper constructs a three- line-four-column curtain antenna array using cage antenna as the antenna array element and obtains a normalizing 3D radiation patterns through conducting simulation with MATLAB. Meanwhile, the relationships between the antenna spacing and the largest directivity coefficient, as well as the communication frequency and largest directivity coefficient are analyzed in this paper. It turns out that the max value will generate when the antenna spacing is around 18 m and the best communication effect will be achieved when the communication frequency is about 12.4 MHz.

  19. Bubble Curtains: Herbivore Exclusion Devices for Ecology and Restoration of Marine Ecosystems?

    Directory of Open Access Journals (Sweden)

    Scott Bennett

    2017-09-01

    Full Text Available Herbivorous fishes play a critical role in maintaining or disrupting the ecological resilience of many kelp forests, coral reefs and seagrass ecosystems, worldwide. The increasing rate and scale of benthic habitat loss under global change has magnified the importance of herbivores and highlights the need to study marine herbivory at ecologically relevant scales. Currently, underwater herbivore exclusions (or inclusions have been restricted to small scale experimental plots, in large part due to the challenges of designing structures that can withstand the physical forces of waves and currents, without drastically altering the physical environment inside the exclusion area. We tested the ability of bubble curtains to deter herbivorous fishes from feeding on seaweeds as an alternative to the use of rigid exclusion cages. Kelps (Ecklonia radiata were transplanted onto reefs with high browsing herbivore pressure into either unprotected plots, exclusion cages or plots protected by bubble curtains of 0.785 m2 and 3.14 m2. Remote underwater video was used to compare the behavioral response of fishes to kelps protected and unprotected by bubble curtains. Kelp biomass loss was significantly lower inside the bubble curtains compared to unprotected kelps and did not differ from kelp loss rates in traditional exclusion cages. Consistent with this finding, no herbivorous fishes were observed entering into the bubble curtain at any point during the experiment. In contrast, fish bite rates on unprotected kelps were 1,621 ± 702 bites h−1 (mean ± SE. Our study provides initial evidence that bubble curtains can exclude herbivorous fishes, paving the way for future studies to examine their application at larger spatial and temporal scales, beyond what has been previously feasible using traditional exclusion cages.

  20. Scientific communication across the Iron Curtain

    CERN Document Server

    Hollings, Christopher D

    2016-01-01

    This monograph provides a concise introduction to the tangled issues of communication between Russian and Western scientists during the Cold War. It details the extent to which mid-twentieth-century researchers and practitioners were able to communicate with their counterparts on the opposite side of the Iron Curtain. Drawing upon evidence from a range of disciplines, a decade-by-decade account is first given of the varying levels of contact that existed via private correspondence and conference attendance. Next, the book examines the exchange of publications and the availability of one side's work in the libraries of the other. It then goes on to compare general language abilities on opposite sides of the Iron Curtain, with comments on efforts in the West to learn Russian and the systematic translation of Russian work. In the end, author Christopher Hollings argues that physical accessibility was generally good in both directions, but that Western scientists were afflicted by greater linguistic difficultie...

  1. The use of sparge curtains for contaminant plume control

    International Nuclear Information System (INIS)

    Molnaa, B.; Dablow, J.

    1994-01-01

    Contamination by petroleum hydrocarbons and organic solvents represents a major impact to soil and groundwater. Following recent research and development, several technologies have evolved to treat saturated zone adsorbed- and dissolved-phase contaminants in situ. These technologies include bioremediation and air sparging. Funnel and gate approaches have been developed at the Waterloo Center for Groundwater Research to control contaminant plume migration and treat dissolved-phase contaminants before allowing migration downgradient and off site. The process consists of using low hydraulic conductivity cutoff walls to funnel groundwater flow through gates that contain in situ bioreactors. These systems can maintain hydraulic control and treat dissolved-phase contaminants at the downgradient margins of plumes, while minimizing, or in some cases eliminating, the need for groundwater pumping. Sparge curtains can be applied to treat dissolved-phase contaminants and prevent downgradient, off-site migration of contaminated groundwater

  2. Curtain color and lighting program in broiler production: I - general performance

    Directory of Open Access Journals (Sweden)

    Valéria Maria Nascimento Abreu

    2011-09-01

    Full Text Available The objective of the present study was to evaluate mortality and performance, darkling beetle population (Alphitobius diaperinus, light intensity, electrical energy consumption and economic efficiency of broilers reared under two lighting programs (nearly continuous or intermittent and two curtain colors (yellow or blue. The experiment was conducted between June, 2004 and May, 2005. Six flocks were sequentially housed in four 12 × 10 m broiler houses divided into 4 pens with 200 birds each. Litter was reused six times or until flock 6. Body weight and feed conversion were determined on days 21, 35, and 42 of each flock. Mortality was recorded daily. Electrical energy consumption was recorded at the end of the grow-out of each flock (every 42 days. A completely randomized design in a 6 × 2 × 2 factorial arrangement (flocks, lighting programs, curtains with four replicates per treatment was applied. Broilers reared in houses with yellow curtains and under nearly continuous lighting programs presented the best feed conversion ratio and the highest body weight. Nearly continuous lighting programs resulted in 1.48 times more sudden deaths and 1.34 times higher general mortality when compared with intermittent lighting programs. Electrical energy consumption was 2.12 times higher in nearly continuous lighting programs in relation to intermittent lighting programs. The presence of darkling beetles was higher in broiler houses with blue curtains and intermittent lighting program. The economic analysis showed the feasibility of using a mixed system, with intermittent light program in winter and spring and nearly continuous lighting program in the summer and autumn, both in broiler houses with yellow curtains.

  3. Numerical study on the effect of width of single curtain on the performance of Savonius wind turbine

    Directory of Open Access Journals (Sweden)

    Yuwono Triyogi

    2018-01-01

    Full Text Available This is a preliminary results of the flow around the Savonius wind turbine with installing curtain plate in front of the returning blade turbine. It was investigated numerically in a uniform flow at Reynolds number of 30,000 and 90,000. The velocity vector and pressure distribution around the turbine were simulate by varying the width of curtain plate relative to the diameter of rotor blade (S/D of = 1.00, 1.02, 1.03, 1.15, 1.41, and 2.00, using STAR CCM++ Software. The k-ɛ realizable as turbulence model was used to visualize the flow phenomena occurred around the turbine, and where in this simulation, the rotor turbine was set static. The results show that it seems the width of the curtain installed in front of the returning blade of the turbine plays an important role in the performance of the turbine. In general, the installing of the curtain in front of the returning blade of the turbine is more effective to improve the turbine performance. This is not necessarily, but depends on the width of the curtain and the number of Reynolds (Re. For the width of the large curtain of S/D = 2 at Re = 90,000, the performance of the turbine is estimated lower than when the turbine without the curtain.

  4. Flow of a falling liquid curtain onto a moving substrate

    International Nuclear Information System (INIS)

    Liu, Yekun; Itoh, Masahiro; Kyotoh, Harumichi

    2017-01-01

    In this study, we investigate a low-Weber-number flow of a liquid curtain bridged between two vertical edge guides and the upper surface of a moving substrate. Surface waves are observed on the liquid curtain, which are generated due to a large pressure difference between the inner and outer region of the meniscus on the substrate, and propagate upstream. They are categorized as varicose waves that propagate upstream on the curtain and become stationary because of the downstream flow. The Kistler’s equation, which governs the flow in thin liquid curtains, is solved under the downstream boundary conditions, and the numerical solutions are studied carefully. The solutions are categorized into three cases depending on the boundary conditions. The stability of the varicose waves is also discussed as wavelets were observed on these waves. The two types of modes staggered and peak-valley patterns are considered in the present study, and they depend on the Reynolds number, the Weber number, and the amplitude of the surface waves. The former is observed in our experiment, while the latter is predicted by our calculation. Both the types of modes can be derived using the equations with periodic coefficients that originated from the periodic base flow due to the varicose waves. The stability analysis of the waves shows that the appearance of the peak-valley pattern requires a significantly greater amplitude of the waves, and a significantly higher Weber number and Reynolds number compared to the condition in which the staggered pattern is observed. (paper)

  5. Flow of a falling liquid curtain onto a moving substrate

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yekun; Itoh, Masahiro [Graduate school of Engineering Mechanics and Systems, University of Tsukuba, Tsukuba, Ibaraki 302-8573 (Japan); Kyotoh, Harumichi, E-mail: yekunliu@hotmail.com [Division of Engineering Mechanics and Systems, University of Tsukuba, Tsukuba, Ibaraki 302-8573 (Japan)

    2017-10-15

    In this study, we investigate a low-Weber-number flow of a liquid curtain bridged between two vertical edge guides and the upper surface of a moving substrate. Surface waves are observed on the liquid curtain, which are generated due to a large pressure difference between the inner and outer region of the meniscus on the substrate, and propagate upstream. They are categorized as varicose waves that propagate upstream on the curtain and become stationary because of the downstream flow. The Kistler’s equation, which governs the flow in thin liquid curtains, is solved under the downstream boundary conditions, and the numerical solutions are studied carefully. The solutions are categorized into three cases depending on the boundary conditions. The stability of the varicose waves is also discussed as wavelets were observed on these waves. The two types of modes staggered and peak-valley patterns are considered in the present study, and they depend on the Reynolds number, the Weber number, and the amplitude of the surface waves. The former is observed in our experiment, while the latter is predicted by our calculation. Both the types of modes can be derived using the equations with periodic coefficients that originated from the periodic base flow due to the varicose waves. The stability analysis of the waves shows that the appearance of the peak-valley pattern requires a significantly greater amplitude of the waves, and a significantly higher Weber number and Reynolds number compared to the condition in which the staggered pattern is observed. (paper)

  6. Case study installation of a HDPE curtain wall with sheetpile tie-in on both ends

    International Nuclear Information System (INIS)

    Schindler, R.M.; Maltese, P.C.

    1997-01-01

    The plans for eliminating the off-site migration of non-aqueous phase liquid (NAPL) from a refinery into a nearby river included the installation of a High Density Polyethylene (HDPE) curtain wall and an underdrain system. A 640 m (2100 lineal feet) HDPE Curtain Wall was installed along the river boundary, tying into an existing sheet pile wall on both ends. The wall varied from approximately 4.5 m (15 feet) deep at the northern end to about 7 m (23 feet) deep at the southern end, running approximately 3 to 3.6 m (10 to 12 feet) inland of an existing wooden bulkhead. The curtain wall was successfully installed through a slurry supported trench. A 930 m (3050 lineal feet) interception/collection trench was installed parallel to the HDPE Curtain Wall, continuing on beyond the curtain wall on the southern end. The depth of the trench varied from approximately 3 to 4 m (10 to 13 feet) deep. A 20.32 cm (8 inch) diameter perforated HDPE header pipe was placed in the trench to convey groundwater and product to two sumps. The trench is 53.34 cm (21 inches) wide and contained aggregate to approximately 0.9 m (3 feet) below ground. This work was accomplished using the bio-polymer slurry drainage trench (BP Drain) technique. This paper briefly describes the construction methods utilized during this project, specifically HDPE curtain wall installation thru a bentonite slurry and tie-in to the existing sheet pile wall

  7. Curtain color and lighting program in broiler production: II. carcass and parts yield and abdominal fat deposition

    Directory of Open Access Journals (Sweden)

    Valéria Maria Nascimento Abreu

    2011-09-01

    Full Text Available The objective of the present study was to evaluate carcass and parts' yield, abdominal fat deposition and breast and foot pad blisters of broilers reared under two lighting programs (nearly continuous or intermittent in broilers houses with yellow and blue curtains. The experiment was conducted between June, 2004 and May, 2005. Six flocks were sequentially housed in four 12 × 10 m broiler houses divided into 4 pens with 200 birds each. The litter was reused six times or until flock 6. A completely randomized design in a 6 × 2 × 2 factorial arrangement (flocks, lighting programs, curtains with four replicates per treatment was applied. A total of 288 birds were evaluated for carcass yield. Curtain color did not affect carcass or parts' yield. The effect of lighting program and curtain color on carcass yield may depend on other factors related to flock. Intermittent lighting program promoted the highest drumstick and thigh yields. Lighting programs and curtain colors did not affect abdominal fat deposition or the presence of breast and foot pad blisters.

  8. Process for contamination containment of a workplace by means of an air jet

    International Nuclear Information System (INIS)

    Meline, F.

    1984-01-01

    Containment of pollution in an area, for example the room where nuclear fuel elements are cut, is obtained by an air curtain directed by a second air jet to improve the containment of pollutants. Contamined air is extracted by a cyclone and filtered [fr

  9. Evaluation of Strategies to Improve the Thermal Performance of Steel Frames in Curtain Wall Systems

    Directory of Open Access Journals (Sweden)

    Ji Hyun Oh

    2016-12-01

    Full Text Available Recently, metal curtain wall systems have been widely used in high-rise buildings due to many advantages, including being lightweight, rapid construction, and aesthetic features. Since the metal frame may lead to lower energy performance, thermal discomfort, and condensation risk due to the high thermal conductivity, its thermal performance can be important for the improvement of the overall thermal performance of the curtain wall system, as well as the energy efficiency of the building envelope. This study aims to evaluate variety of design strategies to improve the thermal performance of steel curtain wall frames. Five base cases and three further steps were selected for two different head profile shapes based on a state-of-the art technology review, and their thermal transmittances were calculated through simulations according to the ISO 12631 standard which is an international standard for calculating thermal transmittance of curtain wall system. Measured results that were obtained from hot-box tests were compared with the calculated results to validate the simulation method of this study. The shape of the head profile did not strongly influence the overall thermal transmittance, and the choice of strategies for the rabbet space was more important. More effective strategies could be decided according to the steps for variation development. This result can serve as a guideline for the design of high-performance curtain wall frames.

  10. The domestic veil: exploring the net curtain through the uncanny and the gothic

    OpenAIRE

    Quarini, Carol

    2015-01-01

    This research aims to develop original creative practice, using the net curtain to reconsider the domestic, through the lenses of the uncanny and the gothic. The net curtain, hanging in the liminal space between the public and the private, is used to embody Freud’s 1919 definition of the uncanny, as the point of slippage between the homely and the unhomely. Also central to this research are ideas about the gothic and gendered domesticity, in particular, the gothic fiction of the mid-nineteent...

  11. Curtain eruptions from Enceladus' south-polar terrain

    Science.gov (United States)

    Spitale, Joseph N.; Hurford, Terry A.; Rhoden, Alyssa R.; Berkson, Emily E.; Platts, Symeon S.

    2015-05-01

    Observations of the south pole of the Saturnian moon Enceladus revealed large rifts in the south-polar terrain, informally called `tiger stripes', named Alexandria, Baghdad, Cairo and Damascus Sulci. These fractures have been shown to be the sources of the observed jets of water vapour and icy particles and to exhibit higher temperatures than the surrounding terrain. Subsequent observations have focused on obtaining close-up imaging of this region to better characterize these emissions. Recent work examined those newer data sets and used triangulation of discrete jets to produce maps of jetting activity at various times. Here we show that much of the eruptive activity can be explained by broad, curtain-like eruptions. Optical illusions in the curtain eruptions resulting from a combination of viewing direction and local fracture geometry produce image features that were probably misinterpreted previously as discrete jets. We present maps of the total emission along the fractures, rather than just the jet-like component, for five times during an approximately one-year period in 2009 and 2010. An accurate picture of the style, timing and spatial distribution of the south-polar eruptions is crucial to evaluating theories for the mechanism controlling the eruptions.

  12. Experimental validation of a local dehumidification system based on cold water droplets and air-to-air heat exchanger

    NARCIS (Netherlands)

    Janssen, E.G.O.N.; Hammink, H.A.J.; Hendriksen, L.J.A.M.

    2015-01-01

    Excessive humidity is a problem in Dutch growing circumstances. A traditional solution is heating and natural ventilation. To save energy a number of energy efficient dehumidification methods are developed, like mechanical ventilation with dry outside air or a curtain of cold water droplets. In this

  13. Water Curtain System Pre-design for Crude Oil Storage URCs : A Numerical Modeling and Genetic Programming Approach

    NARCIS (Netherlands)

    Ghotbi Ravandi, Ebrahim; Rahmannejad, Reza; Karimi-Nasab, Saeed; Sarrafi, Amir; Raoof, Amir

    In this paper the main criteria of the water curtain system for unlined rock caverns (URCs) is described. By the application of numerical modeling and genetic programming (GP), a method for water curtain system pre-design for Iranian crude oil storage URCs (common dimension worldwide) is presented.

  14. A new intelligent curtain control system based on 51 single chip microcomputer

    Science.gov (United States)

    Sun, Tuan; Wang, Yanhua; Wu, Mengmeng

    2017-04-01

    This paper uses 51 (single chip microcomputer) SCM as the operation and data processing center. According to the change of sunshine intensity and ambient temperature, a new type of intelligent curtain control system is designed by adopting photosensitive element and temperature sensor. In addition, the design also has a manual control mode. In the rain, when the light intensity is weak, the open position of the curtain can be set by the user. The system can maximize the user to provide user-friendly operation and comfortable living environment. The system can be applied to home or office environment, with a wide range of applications and simple operation and so on.

  15. Winston Churchill's "Iron Curtain" Address: Implications for the Present.

    Science.gov (United States)

    Bush, George

    1988-01-01

    Evaluates the "Iron Curtain" speech made by Winston Churchill in 1946, discussing its relevance and implications for the present. Examines Churchill's predictions for the future and his assessment of the USSR. Reviews world developments since the speech and proposes foreign policy goals for the next 40 years. (GEA)

  16. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    Science.gov (United States)

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the

  17. Verification of CFD model of plane jet used for smoke free zone separation in case of fire

    Science.gov (United States)

    Krajewski, Grzegorz; Suchy, Przemysław

    2018-01-01

    This paper presents the basic information about the use of air curtains in fire safety, as a barrier for heat and smoke. Mathematical model of an air curtain presented hereallows estimation of velocity of air in various points of space, including the velocity of air from an angled air curtain. Presented equations show how various parameters influence the performance of air curtain. Further, authors present results of their air curtain performance. Authors of that article have done tests in a real scale model. Tests results were used to verify chosen turbulence model and boundary conditions. Results of new studies are presented with regards to the performance of air curtain in case of fire, and final remarks on its design are given.

  18. The Perforated Curtain: Configuring the Public and the Private in Calcutta’s Cabin Culture

    Directory of Open Access Journals (Sweden)

    Twisha Deb

    2017-04-01

    Full Text Available When I was very young, eating out was not a regular activity for our family. On one of such rare occasion we ended up in a restaurant where the waiter made us sit in a cubicle with a curtain on one side. You pull the curtain and it creates a weird sense of privacy. That idea of intimate space in the middle of a busy city intrigued me. Later I found many restaurants in Kolkata where they have this sort of cabin, a private eating area. Starting from pre-independence when they were there to provide some privacy to the ladies of the family who were not allowed to eat in public, the cabin witnessed many private affairs with time, from political discussions to lovers’ silence. With changing time and the emergence of posh cafes with quirky interiors, the shabby little cabins have lost their charm, but the almost empty cabins, some even without the curtains stand there to tell a story of a time gone by.

  19. Parameters Optimization of Curtain Grouting Reinforcement Cycle in Yonglian Tunnel and Its Application

    Directory of Open Access Journals (Sweden)

    Qingsong Zhang

    2015-01-01

    Full Text Available For practical purposes, the curtain grouting method is an effective method to treat geological disasters and can be used to improve the strength and permeability resistance of surrounding rock. Selection of the optimal parameters of grouting reinforcement cycle especially reinforcement cycle thickness is one of the most interesting areas of research in curtain grouting designs. Based on the fluid-structure interaction theory and orthogonal analysis method, the influence of reinforcement cycle thickness, elastic modulus, and permeability on water inflow of tunnel after grouting and stability of surrounding rock was analyzed. As to the water inflow of tunnel after grouting used as performance evaluation index of grouting reinforcement cycle, it can be concluded that the permeability was the most important factor followed by reinforcement cycle thickness and elastic modulus. Furthermore, pore water pressure field, stress field, and plastic zone of surrounding rock were calculated by using COMSOL software under different conditions of reinforcement cycle thickness. It also can be concluded that the optimal thickness of reinforcement cycle and permeability can be adopted as 8 m and 1/100 of the surrounding rock permeability in the curtain grouting reinforcement cycle. The engineering case provides a reference for similar engineering.

  20. Evaluation of compatibility of flowing liquid lithium curtain for blanket with core plasma in fusion reactors

    International Nuclear Information System (INIS)

    Deng Baiquan; Huang Jinhua; Peng Lilin; Yan Jiancheng

    2003-01-01

    A global model analysis of the compatibility of flowing liquid lithium curtain for blanket with core plasma has been performed. The relationships between the surface temperature of lithium curtain and mean effective plasma charges, fuel dilution and produced fusion power have been obtained. Results show that under normal circumstances, the evaporation of liquid lithium does not affect Z eff seriously, but affects fuel dilution and fusion power sensitively. The authors have investigated the relationships between the flow velocity of liquid lithium and its surface temperature rise based on the conditions of the option II of the fusion experimental breeder (FEB-E) design with reversed shear configuration and fairly high power density. The authors concluded that the effects of evaporation from liquid lithium curtain for FEB-E on plasma are negligible even if the flow velocity of liquid lithium is as low as 0.5 m·s -1 . Finally, the sputtering yield of liquid lithium saturated by hydrogen isotopes is briefly discussed

  1. The use of water curtains to protect firemen in case of heavy gas dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Bara, A.; Dusserre, G. [Ecole Nationale Superieure des Techniques Industrielles et des Mines d`Ales (France). Lab. Genie de l`Environnement Industriel

    1997-05-01

    The aim of this paper is to study the effectiveness of the water curtains used by firemen in France to protect people fighting chemical spillage. The effectiveness of these barriers is a reduction in concentration behind it by a factor of 10 at a distance of approximately 13 m and a factor of 3 at a distance of approximately 20 m in the case of ammonia releases. The results of similar studies of a wide variety of toxic gases will provide a quick and reliable tool for firefighters, which will help to define at what distance to place the curtain and predict the concentrations behind it. (UK)

  2. Emissions and Char Quality of Flame-Curtain "Kon Tiki" Kilns for Farmer-Scale Charcoal/Biochar Production

    Science.gov (United States)

    Cornelissen, Gerard; Pandit, Naba Raj; Taylor, Paul; Pandit, Bishnu Hari; Sparrevik, Magnus; Schmidt, Hans Peter

    2016-01-01

    Flame Curtain Biochar Kilns Pyrolysis of organic waste or woody materials yields charcoal, a stable carbonaceous product that can be used for cooking or mixed into soil, in the latter case often termed "biochar". Traditional kiln technologies for charcoal production are slow and without treatment of the pyrolysis gases, resulting in emissions of gases (mainly methane and carbon monoxide) and aerosols that are both toxic and contribute to greenhouse gas emissions. In retort kilns pyrolysis gases are led back to a combustion chamber. This can reduce emissions substantially, but is costly and consumes a considerable amount of valuable ignition material such as wood during start-up. To overcome these problems, a novel type of technology, the Kon-Tiki flame curtain pyrolysis, is proposed. This technology combines the simplicity of the traditional kiln with the combustion of pyrolysis gases in the flame curtain (similar to retort kilns), also avoiding use of external fuel for start-up. Biochar Characteristics A field study in Nepal using various feedstocks showed char yields of 22 ± 5% on a dry weight basis and 40 ± 11% on a C basis. Biochars with high C contents (76 ± 9%; n = 57), average surface areas (11 to 215 m2 g-1), low EPA16—PAHs (2.3 to 6.6 mg kg-1) and high CECs (43 to 217 cmolc/kg)(average for all feedstocks, mainly woody shrubs) were obtained, in compliance with the European Biochar Certificate (EBC). Gas Emission Factors Mean emission factors for the flame curtain kilns were (g kg-1 biochar for all feedstocks); CO2 = 4300 ± 1700, CO = 54 ± 35, non-methane volatile organic compounds (NMVOC) = 6 ± 3, CH4 = 30 ± 60, aerosols (PM10) = 11 ± 15, total products of incomplete combustion (PIC) = 100 ± 83 and NOx = 0.4 ± 0.3. The flame curtain kilns emitted statistically significantly (p<0.05) lower amounts of CO, PIC and NOx than retort and traditional kilns, and higher amounts of CO2. Implications With benefits such as high quality biochar, low emission

  3. PERMEABILITY OF SAVCIBEY DAM (BİLECİK AXIS LOCATION AND DESIGN OF GROUT CURTAIN

    Directory of Open Access Journals (Sweden)

    Mustafa Can Canoğlu

    2016-12-01

    Full Text Available This study comprise the design of the planned grout curtain in Savcıbey Dam (Söğüt/Bilecik in order to provide impermeability along the dam axis. Within the context of field studies, engineering geology map was generated, ground investigation drilling was realized and permeability tests were performed. Within the field studies, the joint conditions of the geological units (Triassic aged Bozuyük Metamorphic schists under the dam axis and its effect on permeability was observed considering the positions of the discontinuities with regard to the dam axis location. Orientation of discontinuities generally have strikes changing between N – S and NNE – SSW. 5 boreholes on dam axis, 2 boreholes on cofferdam, 3 boreholes on diversion tunnel and 2 boreholes on spillway total 245 m ground investigation borehole were drilled. In order to determine the permeability profile of dam axis and design the grout curtain, Lugeon tests in Bozuyük Metamorphic units observed in dam axis, falling head permeability tests in alluviums observed in thalveg and slope debris observed in right abutment were performed. Lugeon tests realized in Bozuyük Metamorphic units show that the unit is generally permeable and partly low permeable. Alluvium and slope debris are highly permeable. In addition, drilling works realized in dam axis shows that the augmentation of the weathering degree cause an increase of permeability in Triassic aged Bozüyük Metamorphic schists. As a result of these studies information about the permeability of Savcıbey Dam was collected and the grout curtain hole was designed. Accordingly, it is predicted that approximately 40 m depth of grout curtain from the stripping excavation with the depth of 1.50 m would prevent the possible leakages.

  4. Design and operation problems related to water curtain system for underground water-sealed oil storage caverns

    Directory of Open Access Journals (Sweden)

    Zhongkui Li

    2016-10-01

    Full Text Available The underground water-sealed storage technique is critically important and generally accepted for the national energy strategy in China. Although several small underground water-sealed oil storage caverns have been built in China since the 1970s, there is still a lack of experience for large-volume underground storage in complicated geological conditions. The current design concept of water curtain system and the technical instruction for system operation have limitations in maintaining the stability of surrounding rock mass during the construction of the main storage caverns, as well as the long-term stability. Although several large-scale underground oil storage projects are under construction at present in China, the design concepts and construction methods, especially for the water curtain system, are mainly based on the ideal porosity medium flow theory and the experiences gained from the similar projects overseas. The storage projects currently constructed in China have the specific features such as huge scale, large depth, multiple-level arrangement, high seepage pressure, complicated geological conditions, and high in situ stresses, which are the challenging issues for the stability of the storage caverns. Based on years' experiences obtained from the first large-scale (millions of cubic meters underground water-sealed oil storage project in China, some design and operation problems related to water curtain system during project construction are discussed. The drawbacks and merits of the water curtain system are also presented. As an example, the conventional concept of “filling joints with water” is widely used in many cases, as a basic concept for the design of the water curtain system, but it is immature. In this paper, the advantages and disadvantages of the conventional concept are pointed out, with respect to the long-term stability as well as the safety of construction of storage caverns. Finally, new concepts and principles

  5. PECULIARITIES OF DESIGN OF CURTAIN WALL SYSTEMS TO ASSURE THERMAL INSULATION

    Directory of Open Access Journals (Sweden)

    Golunov Sergej Anatolevich

    2012-10-01

    The results of laboratory tests (given the adjustments for permissible tolerances may be regarded as the principal criteria in the assessment of applicability of a curtain wall system in the course of a major building repair project or a new construction to assure the required reliability and durability.

  6. Study on construction technology of metro tunnel under a glass curtain wall

    Science.gov (United States)

    Zhang, Jian; Yu, Deqiang

    2018-03-01

    To ensure the safety of the glass curtain wall building above loess tunnel and get an optimal scheme, an elastic-plastic FEM model is established to simulate three reinforcement schemes based on a tunnel section in Xi’an Metro Line 3. The results show that the settlement value of the optimal scheme is reduced by 69.89% compared with the drainage measures, and the uneven settlement value is reduced by 57.5%. The construction points, technical processes and technical indexes of the optimal scheme are introduced. According to the actual project, the cumulative settlement of the building under construction is 16mm, which meets the control standards. According to the actual project, the cumulative settlement of the glass curtain wall building is 16mm, which meets the control standards. The reinforcement scheme can provide some reference for the design and construction of the metro in loess area.

  7. Construction Technology and Management of Stone Curtain Wall%石材幕墙的施工工艺及施工管理

    Institute of Scientific and Technical Information of China (English)

    黄博杰

    2015-01-01

    由于石材幕墙整体效果美观,颜色均匀一致,具有较好的耐久性且不会造成玻璃幕墙所导致的光污染,目前越来越多的住宅、酒店、写字楼的外墙用石材来进行装饰。随着其广泛地运用,对石材幕墙的施工进行管理显得日益重要。该文将从石材幕墙的施工工艺及施工管理的质量、安全、进度三方面来进行分析。%Due to stone curtain wall’s merits of the overall satisfactory effect,consistent color,good durability and no light pollution generally caused by glass curtain wall,stone is increasingly widely used for the exterior wall decora-tion of residential houses,hotels and office buildings.With the wide application of stone curtain wall,the importance of the construction management of stone curtain wall is increasingly obvious.This paper briefly studies the stone cur-tain wall from aspects of the quality,safety and process of construction technology and construction management.

  8. Evaluation of the effectiveness of grouting curtain on the basis of the analysis of groundwater temperature fluctuations behind the dam

    Directory of Open Access Journals (Sweden)

    Orekhov Vyacheslav Valentinovich

    2015-04-01

    Full Text Available In the article the authors considered the technique of evaluating the performance of a grouting curtain basing on the analysis of mathematical forecasting and regular measurements of water temperature in the reservoir and in the rock mass behind the dam. The initial data for the solution of heat transfer problem are the rate of filtration, obtained from the solution of the stationary problem of filtration, and the experimental factor, generalizing thermophysical properties of rocks. For calculating the period of time from to the change of the water temperature in the reservoir till the change of water temperature at the reference point of the rock mass a computer program was designed, which allows defining the path and time of filtration from the reservoir to the reference point in the rock mass with the help of the reverse conversion on flow lines. The calculation was carried out from the point in question in the rock mass till the crossing paths of filtration with the bottom boundary of the reservoir. As an example, we present the results of computational studies of filtration and temperature regimes in the rock foundation of a concrete dam at the design work of the grouting curtain and in case of the presence of pervious area. The calculations were performed with a time step dt = 2 days. At each time step, with account of water motion along the lines of the current through the rock mass, the previous position of the reference points in space has been determined, for which the value of the velocity vector of filtration field was corrected. In the first case, the motion of water from the reservoir was carried out in the circumvention of the grouting curtain. In the second case, the motion of water took place from the reservoir through the permeable portion of the grouting curtain. The change of the water temperature during its seepage from the water reservoir through permeable area of grouting curtain because of conductive heat transmission in

  9. Missing in Action: Where Are the Air Force’s Geographic Combatant Commanders

    Science.gov (United States)

    2011-06-01

    would usher in a more Kantian world order.19 In 1993, Charles Kegley implied that the fall of the iron curtain was a “potent catalyst” pushing the...the values point to unchanging characteristics of the profession of arms.7 The values also help Air Force leadership determine the ethical climate...follow ethical practices in the acquisitions field. During the same period, Air Force General Gregory Martin was nominated to become the first non

  10. 石材幕墙安装技术要点控制%The Control Points of Stone Curtain Wall Installation Technology

    Institute of Scientific and Technical Information of China (English)

    陈慧

    2013-01-01

      随着经济的发展,城市建筑外墙结构采用天然石材幕墙的不断增多。石材幕墙具有独特的艺术风格、高雅的外在造型,能使城市景观得到进一步的提升。石材幕墙的施工方法分为干挂法和湿挂法。本文着重针对干挂法石材幕墙安装的技术要点与质量控制进行探讨。%With the development of economy, exterior wal st-ructure of urban architecture using the natural stone curtain wal structure is increasing. The external appearance of stone curtain wal has a unique artistic style, elegant, can make the city landscape has been further improved. Construction metho-d for stone curtain wal is divided into dry hanging method and wet hanging method. This paper discusses focused on the law of dry hanging stone curtain wal technology points and the quality control of instal ation.

  11. Physical modeling of steel flow in a tun dish equipped with a turbulence inhibitor and a gas curtain

    International Nuclear Information System (INIS)

    Perez-Labra, M.; Diaz-Cruz, M.; Palafox-Ramos, J.; Avila-Davila, E. O.; Patino-Cardona, F.

    2005-01-01

    A 2/5 scale model with a transparent plastic sheet was built based on Froude criterion in which eight cases were studied by PIV technique, maintaining a constant gas flow rate of 596 ml/min and only varying the gas curtain position. The results permitted to get Residence Time Distribution (RTD) curves, and from the data processing it was found that combining Turbulence Inhibitor (TI) with the adequate gas curtain position it is enhanced the plug volume. The case VII presented the best results increasing the plug volume in 131.85% in comparison with the case IV which was taken as the reference one. (Author) 10 refs

  12. Field experiment and numerical simulation of coupling non-Darcy flow caused by curtain and pumping well in foundation pit dewatering

    Science.gov (United States)

    Wang, Jianxiu; Liu, Xiaotian; Wu, Yuanbin; Liu, Shaoli; Wu, Lingao; Lou, Rongxiang; Lu, Jiansheng; Yin, Yao

    2017-06-01

    High-velocity non-Darcy flow produced larger drawdown than Darcy flow under the same pumping rate. When the non-Darcy flow caused by curtain met non-Darcy flow caused by pumping wells, superposition and amplification effect occurred in the coupling area, the non-Darcy flow was defined as coupling non-Darcy flow. The coupling non-Darcy flow can be produced and controlled using different combination of curtain and pumping wells in foundation pit dewatering to obtain the maximum drawdown using the minimum pumping rate. The Qianjiang Century City Station foundation pit of Hangzhou subway, China, was selected as background. Field experiments were performed to observe the coupling non-Darcy flow in round gravel. A generalized conceptual model was established to study the coupling effect under different combination of curtain and pumping wells. Numerical simulations of the coupling non-Darcy flow in foundation pit dewatering were carried out based on the Forchheimer equation. The non-Darcy flow area and flow velocity were influenced by the coupling effect. Short filter tube, large pumping rate, small horizontal distance between filter tube and diaphragm wall, and small vertical distance between the filter tube and confined aquifer roof effectively strengthened the coupling effect and obtained a large drawdown. The pumping wells installed close to a curtain was an intentional choice designed to create coupling non-Darcy flow and obtain the maximize drawdown. It can be used in the dewatering of a long and narrow foundation pit, such as a subway foundation pit.

  13. Evaporation-preventive device for nuclear reactor pool water

    International Nuclear Information System (INIS)

    Kurusu, Yoshihisa; Akabori, Shiro.

    1986-01-01

    Purpose: To prevent pool water from evaporating by a great amount in a reactor pool such as a spent fuel storing pool. Constitution: Air discharge and in-take ports are disposed just above the surface of the pool water and charge and discharge of airs are forcively carried out to form air curtains above the pool water. Water vapor evaporated from the surface of the pool water does not diffuse above the air curtains due to the air stream of the curtains, but is intaken into the intake port and then condensated into water by a steam condensator and re-supplied to the pool. Since diffusion of water vapor and radioactive materials are suppressed above the air curtains, the working circumstance in the pool chamber can be maintained desirably thereby keeping the radioactivity dose in the atmosphere. Further, incorporation of dusts from above into the pool can also be prevented by the air curtains to provide an effect for the prevention of radioactive contamination. Further, since covers are not used, visual observation can be insured. (Kawakami, Y.)

  14. Boron concentration evolution in the temporary curtains of a BWR reactor. Burcur code

    International Nuclear Information System (INIS)

    Cano Aguado, M.; Perlado Martin, J.M.; Minguez Torres, E.

    1977-01-01

    The theoretical model and the user's guide of the code Burcur is included. This code analyzes the burnable poison concentration of the temporary curtains as a function of time, for BWR reactors of the 7 x 7 design. The computing time being reasonably short, the number of burnup steps is as high as necessary.(author) [es

  15. Delivering COBie data - Focus on curtain walls and building envelopes

    DEFF Research Database (Denmark)

    Karlshøj, Jan; Borin, P.; Carradori, M.

    COBie is a standard data framework whose main purpose is to transmit useful, reliable and us-able information collected throughout the whole building process and to be consumed in order to properly maintain the facility. Focusing on Facility Management information exchanges and considering the UK...... BIM policies and requirements, this paper shows the results obtained applying COBie to complex products such as curtain walls. Two Information Delivery Manuals (IDMs) were also developed, in order to provide a com-monly known and standardized framework, which can regulate the COBie-based information...

  16. Development of air conditioning system and labor saving technology for efficient hydroponic cultivation; Konoritsuna suiko saibai no tame no kucho to shoryokuka gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Okano, T.; Terazoe, H.; Shoji, K. [Central Research Institute of Electric Power Industry, Tokyo (Japan); Yonezawa, K.; Otani, F. [Chugoku Electric Power Co. Inc., Hiroshima (Japan); Sekiyama, T.; Kosakai, K.; Sato, H.

    1997-06-01

    Equipment which made experiments on air conditioning and hydroponic cultivation possible was set up at the technical research center of the Chugoku Electric Power Co., to study an air conditioning system using night power and energy saving technology for the cultivation. Vegetables suitable to the cultivation were selected. For air conditioning, adopted was a water heat storage air conditioning system using night power. The space between the shade curtain and the greenhouse roof was ventilated to prevent increase in cooling load caused by rise in curtain temperature. Moreover, the cultivation equipment was covered with transparent vinyl film to cool the inside of the equipment. The hydroponic cultivation equipment was trially manufactured which makes the continued production by one worker possible. The cultivation of spinach, leaf lettuce and chingensai throughout the year became possible. The yield of chingensai reached the target, but those of spinach and leaf lettuce were approximately 70% of the targets. Vegetables to be produced in the air-conditioned greenhouse by hydroponic cultivation are thought to be those that can have added values such non-pesticides and ingredients, young plants which were increased by cutting or tissue culturing, etc. 5 refs., 19 figs., 8 tabs.

  17. The Effects of Curtain Airbag on Occupant Kinematics and Injury Index in Rollover Crash

    Directory of Open Access Journals (Sweden)

    Hongyun Li

    2018-01-01

    Full Text Available Background. Occupant injuries in rollover crashes are associated with vehicle structural performance, as well as the restraint system design. For a better understanding of the occupant kinematics and injury index in certain rollover crash, it is essential to carry out dynamic vehicle rollover simulation with dummy included. Objective. This study focused on effects of curtain airbag (CAB parameters on occupant kinematics and injury indexes in a rollover crash. Besides, optimized parameters of the CAB were proposed for the purpose of decreasing the occupant injuries in such rollover scenario. Method and Material. The vehicle motion from the physical test was introduced as the input for the numerical simulation, and the 50% Hybrid III dummy model from the MADYMO database was imported into a simulation model. The restraint system, including a validated CAB module, was introduced for occupant kinematics simulation and injury evaluation. TTF setting, maximum inflator pressure, and protection area of the CAB were analysed. Results. After introducing the curtain airbag, the maximum head acceleration was reduced from 91.60 g to 49.52 g, and the neck Mx and neck Fz were reduced significantly. Among these CAB parameters, the TTF setting had the largest effect on the head acceleration which could reduce 8.6 g furthermore after optimization. The neck Fz was decreased from 3766.48 N to 2571.77 N after optimization of CAB protection area. Conclusions. Avoiding hard contact is critical for the occupant protection in the rollover crashes. The simulation results indicated that occupant kinematics and certain injury indexes were improved with the help of CAB in such rollover scenario. Appropriate TTF setting and inflator selection could benefit occupant kinematics and injury indexes. Besides, it was advised to optimize the curtain airbag thickness around the head contact area to improve head and neck injury indexes.

  18. Review of Ice-Control Methods at Lock 8, Welland Canal, Port Colborne, Ontario

    Science.gov (United States)

    2016-05-01

    passes through the first air curtain (i.e., by live video camera mounted near the bullnose with a monitor at the lock house) and activate the second...methods, including an air curtain to hold ice above the lock, bubblers and mechanical means to reduce the ice accumulation on the lock walls, and...modifications include reducing the air - curtain and bubblers nozzle size to make the flow across the manifolds more uniform. The only system that the St

  19. Electrostatic curtain studies

    International Nuclear Information System (INIS)

    Meyer, L.C.

    1992-05-01

    This report presents the results of experiments using electrostatic curtains (ESCS) as a transuranic (TRU) contamination control technique. The TRU contaminants included small (micrometer to sub micrometer) particles of plutonium and americium compounds associated with defense-related waste. Three series of experiments were conducted. The first was with uncontaminated Idaho National Engineering Laboratory (INEL) soil, the second used contaminated soil containing plutonium-239 (from a mixture of Rocky Flats Plant contaminated soil and INEL uncontaminated soil), and the third was uncontaminated INEL soil spiked with plutonium-239. All experiments with contaminated soil were conducted inside a glove box containing a dust generator, low volume cascade impactor (LVCI), electrostatic separator, and electrostatic materials. The data for these experiments consisted of the mass of dust collected on the various material coupons, plates, and filters; radiochemical analysis of selected samples; and photographs, as well as computer printouts giving particle size distributions and dimensions from the scanning electron microscope (SEM). The following results were found: (a) plutonium content (pCi/g) was found to increase with smaller soil particle sizes and (b) the electrostatic field had a stronger influence on smaller particle sizes compared to larger particle sizes. The SEM analysis indicated that the particle size of the tracer Pu239 used in the spiked soil experiments was below the detectable size limit (0.5 μm) of the SEM and, thus, may not be representative of plutonium particles found in defense-related waste. The use of radiochemical analysis indicated that plutonium could be found on separator plates of both polarities, as well as passing through the electric field and collecting on LVCI filters

  20. Generator of a dense atomic gas curtain (for use in Intersecting Storage Rings)

    CERN Document Server

    Zankel, K

    1975-01-01

    A supersonic beam source is described which continuously generates a gas curtain for the proton beam profile observation in the Intersecting Storage Rings at CERN. Its maximum intensity is 10/sup 20 / atoms/sr s. A commonly used theoretical model for the determination of the intensity downstream of the source is discussed. Some results about the condensation behaviour of sodium vapour on metallic substrate surfaces are reported. (8 refs).

  1. Analysis on the construction technology of stone curtain wall in building engineering%谈钢结构技术在土木工程施工中的应用

    Institute of Scientific and Technical Information of China (English)

    齐鑫

    2016-01-01

    This paper introduced the construction characteristics of stone curtain wall,from the positioning,lightning protection connection,stone panel installation,pendant installation and other aspects,elaborated the construction technology of stone curtain wall,and discussed the methods to improve the construction quality,conducive to promote the popularization and application of stone curtain wall.%结合实践经验,分析了土木工程中钢结构施工技术存在的问题,并从吊装施工、焊接技术、现场勘测、材料选择四方面,提出了改进钢结构施工技术的建议,从而提高钢结构的施工水平。

  2. Air barrier systems: Construction applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrault, J.C

    1989-01-01

    An examination is presented of how ordinary building materials can be used in an innovative manner to design, detail, and construct effective air barrier systems for common types of walls. For residential construction, the air drywall approach uses the interior gypsum board as the main component of the wall air barrier system. Joints between the gypsum board and adjacent materials or assemblies are sealed by gaskets. In commercial construction, two different techniques are employed for using gypsum board as air barrier material: the accessible drywall and non-accessible drywall approaches. The former is similar to the air drywall approach except that high performance sealants are used instead of gaskets. In the latter approach, exterior drywall sheathing is the main component of the air barrier system; joints between boards are taped and joints between boards and other components are sealed using elastomeric membrane strips. For various types of commercial and institutional buildings, metal air barrier systems are widely used and include pre-engineered curtain walls or sheet metal walls. Masonry wall systems are regarded as still the most durable, fireproof, and soundproof wall type available but an effective air barrier system has typically been difficult to implement. Factory-made elastomeric membranes offer the potential to provide airtightness to masonry walls. These membranes are applied on the entire masonry wall surface and are used to make airtight connections with other building components. Two types of product are available: thermofusible and peel-and-stick membranes. 5 figs.

  3. Sunlight-driven eco-friendly smart curtain based on infrared responsive graphene oxide-polymer photoactuators.

    Science.gov (United States)

    Leeladhar; Raturi, Parul; Singh, J P

    2018-02-27

    Photomechanical actuation is the conversion of light energy into mechanical energy through some smart materials. Infrared-responsive smart materials have become an emerging field of research due to easy availability and eco-friendly nature of their stimulus in the form of sunlight, which contains about 50% of near-infrared(nIR) making these materials useful at macro-scale photoactuator applications. Here, we demonstrate fabrication of highly versatile nIR triggered photoactuators based on graphene oxide/polycarbonate bilayers that offers fast, low-cost fabrication, large deflection, reversible actuation and wavelength-selective response. The photoactuators are realized by vacuum filtration of graphene oxide/water dispersion through polycarbonate membrane resulting graphene oxide/polymer bilayer structure. The photoactuation response was measured in the form of deflection from equilibrium position as a result of infrared-irradiation. The deflection is caused by the generated thermal stress at the interface of bilayers due to mismatch of thermal expansion coefficient as a results of nIR absorption by graphene oxide and subsequent temperature rise. A maximum deflection of 12 mm (circular-shaped structure with diameter 28 mm) with corresponding bending curvature of 0.33 cm -1 was shown by this photoactuator for illumination intensity of 106 mW/cm 2 . Few applications of these photoactuators such as sunlight-driven smart curtain, infrared actuated curtain and self-folding box are also demonstrated.

  4. 77 FR 48492 - Event Data Recorders

    Science.gov (United States)

    2012-08-14

    ... that [cir] Involve side or side curtain/tube air bags such that EDR data would only need to be locked... deployable restraints other than frontal, side or side/curtain air bags such that EDR data would not need to... definitions to alleviate any uncertainties in multiple event crashes; Revised certain sensor ranges and...

  5. PHITS simulations of the Protective curtain experiment onboard the Service module of ISS: Comparison with absorbed doses measured with TLDs

    Czech Academy of Sciences Publication Activity Database

    Ploc, Ondřej; Sihver, L.; Kartashov, D.; Shurshakov, V.; Tolochek, R. V.

    2013-01-01

    Roč. 52, č. 11 (2013), s. 1911-1918 ISSN 0273-1177 Institutional support: RVO:61389005 Keywords : protective curtain experiment * shielding of cosmic radiation * PHITS simulations * ISS Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.238, year: 2013

  6. Analysis on the construction technology of stone curtain wall in building engineering%关于建筑工程中石材幕墙施工工艺技术的探析

    Institute of Scientific and Technical Information of China (English)

    李苏慧

    2016-01-01

    This paper introduced the construction characteristics of stone curtain wall,from the positioning,lightning protection connection,stone panel installation,pendant installation and other aspects,elaborated the construction technology of stone curtain wall,and discussed the methods to improve the construction quality,conducive to promote the popularization and application of stone curtain wall.%介绍了石材幕墙的施工特点,从定位放线、防雷连接、石材面板安装、挂件安装等方面,阐述了石材幕墙的施工技术,以及提高其施工质量的方法,有利于促进石材幕墙的推广应用。

  7. Influence of PVA and CMC on the Properties of Pigment Coating Colors and their Effects on Curtain Stability

    Directory of Open Access Journals (Sweden)

    Eun Heui Choi

    2015-09-01

    Full Text Available The influence of polyvinyl alcohol (PVA and carboxymethyl cellulose (CMC on the properties of ground calcium carbonate (GCC and clay coating colors, as well as its effect on curtain stability during the coating process was investigated. Based on the experimental results of the zeta potential, sediment porosity, rheological measurements, the floc formation mechanisms of the cobinders were proposed. The zeta potential decreased with an increase in the amount of added PVA, while it barely changed when CMC was added. This was attributed to the adsorption of PVA onto the pigment surface, while the adsorption of CMC was hindered by electrostatic repulsion. CMC cobinder increased the low-shear viscosity, but it resulted in relatively low viscosity under high-shear conditions, indicating the disruption of the formed flocs under high shear. The destabilization mechanism of the curtain coating differed depending on the type of cobinder. The PVA cobinder flocculates the coating color via a gelling mechanism, while the CMC cobinder flocculates the colors via a depletion flocculation mechanism.

  8. Study on pollution control in residential kitchen based on the push-pull ventilation system

    DEFF Research Database (Denmark)

    Zhou, Bin; Chen, Feng; Dong, Zhibo

    2016-01-01

    Highlights •The push-pull ventilation system is proposed to improve IAQ inside kitchen, where air is supplied through slot air curtain and then exhausted through range hood. •CO2 reduction efficiency with application of air curtain in experiment and simulation in breathing zone was 23.7% and 23.......1%, respectively. •By orthogonal method, the influence of factors on pollution control of the push-pull ventilation system was presented....

  9. Performance of shelter in coal mines agains smoke problems. Konai taihisho no kemuri ni taisuru seino

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, S.; Shikada, N.; Tanaka, M.; Kinoshita, M. (Coal Mine Safety Research Center, Kyushu, Fukuoka (Japan))

    1991-10-25

    Relation between a coal mine shelter and smoke was discussed. An enclosing method using combination of ceder boards and vinyl curtains affect greatly the amount of leaking air and the smoke entrance because of tightness of the vinyl curtains changing with temperatures and time. Rope curtains and air curtains show very little effect of preventing smoke from coming in. Upper levels in a shelter restrict the range of sight and have carbon monoxide in higher concentration, whereby people in the shelter are required to take a low posture. It is possible to block smoke and carbon monoxide from coming into a shelter at fire by means of keeping the shelter supplied with certain amount of pressurized air. The time required for smoke to enter a shelter is as relatively short as about 5 to 6 minutes, but 40 minutes or longer is required to discharge it, hence a shelter must be so devised that smoke can never enter it. 3 refs., 14 figs.

  10. Onboard cross-calibration of the Pille-ISS Detector System and measurement of radiation shielding effect of the water filled protective curtain in the ISS crew cabin

    International Nuclear Information System (INIS)

    Szántó, P.; Apáthy, I.; Deme, S.; Hirn, A.; Nikolaev, I.V.; Pázmándi, T.; Shurshakov, V.A.; Tolochek, R.V.; Yarmanova, E.N.

    2015-01-01

    As a preparation for long duration space missions it is important to determine and minimize the impact of space radiation on human health. One of the methods to diminish the radiation burden is using an additional local shielding in the places where the crewmembers can stay for longer time. To increase the crew cabin shielding a special protective curtain was designed and delivered to ISS in 2010 containing four layers of hygienic wipes and towels providing an additional shielding thickness of about 8 g/cm"2 water-equivalent matter. The radiation shielding effect of the protective curtain, in terms of absorbed dose, was measured with the thermoluminescent Pille-ISS Detector System. In order to verify the reliability of the Pille system an onboard cross-calibration was also performed. The measurement proved that potentially 25% reduction of the absorbed dose rate in the crew cabin can be achieved, that results in 8% (∼16 μGy/day) decrease of the total absorbed dose to the crew, assuming that they spend 8 h in the crew cabin a day. - Highlights: • The dose level in the ISS Zvezda crew quarters is higher than the average dose level in the module. • A shielding made of hygienic wipes and towels was set up onboard as additional protection. • Onboard cross calibration of the Pille-ISS space dosimeter (TL) system was performed. • The shielding effect of the protective curtain in terms of absorbed dose was measured with the onboard Pille system. • The shielding effect of the protective water curtain is approximately 24 ± 9% in absorbed dose.

  11. Air bubbles induce a critical continuous stress to prevent marine biofouling accumulation

    Science.gov (United States)

    Belden, Jesse; Menesses, Mark; Dickenson, Natasha; Bird, James

    2017-11-01

    Significant shear stresses are needed to remove established hard fouling organisms from a ship hull. Given that there is a link between the amount of time that fouling accumulates and the stress required to remove it, it is not surprising that more frequent grooming requires less shear stress. One approach to mitigate marine biofouling is to continuously introduce a curtain of air bubbles under a submerged surface; it is believed that this aeration exploits the small stresses induced by rising bubbles to continuously prevent accumulation. Although curtains of rising bubbles have successfully prevented biofouling accumulation, it is unclear if a single stream of bubbles could maintain a clean surface. In this talk, we show that single bubble stream aeration can prevent biofouling accumulation in regions for which the average wall stress exceeds approximately 0.01 Pa. This value is arrived at by comparing observations of biofouling growth and prevention from field studies with laboratory measurements that probe the associated flow fields. We also relate the spatial and temporal characteristics of the flow to the size and frequency of the rising bubbles, which informs the basic operating conditions required for aeration to continuously prevent biofouling accumulation.

  12. Development of a ventilation system to remove odors and dust in a large indoor space; Daikukan no shuki funjin jokyo kanki system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kadoya, M.; Moteki, M.; Tatsumi, T.; Enokida, D.; Miyagi, H.; Maruoka, T. [Okumura Corp., Osaka (Japan)

    1997-07-31

    The ventilation system for removing odor and dust was studied for the waste stock yard and working yard of a segregated waste stock facility of 17,280m{sup 3} in air volume. The developed ventilation system includes the air curtain and wind shield plate between the waste stock yard and working yard. Air curtain flow is formed by jet stream from nozzles installed at certain constant intervals. This system was developed through air flow analysis, model experiment, and field measurement. The air flow analysis pointed out that reverse flow derived from a part of air flow contaminates the working yard, however, this system can exclude such reverse flow and reduce CO2 concentration to 1/80. The model experiment result showed that this system can reduce CO2 concentration to 1/18. The field measurement confirmed the air curtain effect by smoke visualization. In the measurement of dummy dust concentration generated for 15min, this system was possible to reduce the concentration to 1/7. 4 refs., 18 figs., 6 tabs.

  13. Détente from the Air: Monitoring Air Pollution during the Cold War.

    Science.gov (United States)

    Rothschild, Rachel

    During the period of détente in the 1970s, a Norwegian proposal to construct an air pollution monitoring network for the European continent resulted in the first concrete collaboration between the communist and capitalist blocs after the 1975 Helsinki Accords. Known as the "European-wide monitoring programme" or EMEP, the network earned considerable praise from diplomats for facilitating cooperation across the Iron Curtain. Yet as this article argues, EMEP was strongly influenced by the politics of détente and the constraints of the Cold War even as it helped to decrease tensions. Concerns about national security and sharing data with the enemy shaped both the construction of the monitoring network and the modeling of pollution transport. The article also proposes that environmental monitoring systems like EMEP reveal the ways in which observational technologies can affect conceptions of the natural world and the role of science in public policy.

  14. Air barrier details: How effective are they

    Energy Technology Data Exchange (ETDEWEB)

    A project was initiated to measure the air leakage through three typical details in wood frame walls: the header joist, electric outlets, and window openings. Three construction methods were tested: the poly approach, where a sealed internal polyethylene sheet and caulking provide the air barrier; an external air barrier approach using a continuous vapor permeable membrane sandwiched between two layers of external wall sheathing; and the airtight drywall approach (ADA), where the interior gypsum board finish along with framing and gaskets are the air barrier. Twelve sample panels using each of the three details were built using each of the construction approaches. A traditional wood-frame wall construction detail, with no effort made to create a continuous air barrier, was also built and tested for comparison. The samples were put in a test chamber so that air pressures could create infiltration or exfiltration through the panel under loads similar to those due to wind action. Measurements were made at several stages during construction of each sample to see the effect of different components on the air leakage. Overall, all but the traditional samples and the ADA electrical outlet panel exceeded the current tightness standards for glass and aluminum curtain walls. All three approaches could meet the airtightness standards of the R-2000 program. The total air leakage calculated for each approach is under 20% of that in traditional construction. Of the details tested, window detailing offers the greatest potential for increasing overall airtightness compared to traditional methods. 1 ref., 2 figs., 1 tab.

  15. Evidence for Ventilation through Collective Respiratory Movements in Giant Honeybee (Apis dorsata) Nests

    Science.gov (United States)

    Kastberger, Gerald; Waddoup, Dominique; Weihmann, Frank; Hoetzl, Thomas

    2016-01-01

    The Asian giant honeybees (Apis dorsata) build single-comb nests in the open, which makes this species particularly susceptible to environmental strains. Long-term infrared (IR) records documented cool nest regions (CNR) at the bee curtain (nCNR = 207, nnests > 20) distinguished by marked negative gradients (ΔTCNR/d 0) displaying the Venturi effect, which evidences funnel properties of CNRs. The air flows inwards through CNRs, which is verified by the negative spatial gradient ΔTCNR/d, by the positive grading of TCNR with Tamb and lastly by fanners which have directed their abdomens towards CNRs. Rare cases of RAT bee curtain (for ΔACNR/Δt > +0.4 cm2/s) displaying “inhalation” and “exhalation” cycling. “Inhalation” could be boosted by bees at the inner curtain layers, which stretch their extremities against the comb enlarging the inner nest lumen and thus causing a pressure fall which drives ambient air inwards through CNR funnels. The relaxing of the formerly “activated” bees could then trigger the “exhalation” process, which brings the bee curtain, passively by gravity, close to the comb again. That way, warm, CO2-enriched nest-borne air is pressed outwards through the leaking mesh of the bee curtain. This ventilation hypothesis is supported by IR imaging and laser vibrometry depicting CNRs in at least four aspects as low-resistance convection funnels for maintaining thermoregulation and restoring fresh air in the nest. PMID:27487188

  16. Effectiveness and feasibility of long-lasting insecticide-treated curtains and water container covers for dengue vector control in Colombia: a cluster randomised trial.

    Science.gov (United States)

    Quintero, Juliana; García-Betancourt, Tatiana; Cortés, Sebastian; García, Diana; Alcalá, Lucas; González-Uribe, Catalina; Brochero, Helena; Carrasquilla, Gabriel

    2015-02-01

    Long-lasting insecticide-treated net (LLIN) window and door curtains alone or in combination with LLIN water container covers were analysed regarding effectiveness in reducing dengue vector density, and feasibility of the intervention. A cluster randomised trial was conducted in an urban area of Colombia comparing 10 randomly selected control and 10 intervention clusters. In control clusters, routine vector control activities were performed. The intervention delivered first, LLIN curtains (from July to August 2013) and secondly, water container covers (from October to March 2014). Cross-sectional entomological surveys were carried out at baseline (February 2013 to June 2013), 9 weeks after the first intervention (August to October 2013), and 4-6 weeks after the second intervention (March to April 2014). Curtains were installed in 922 households and water container covers in 303 households. The Breteau index (BI) fell from 14 to 6 in the intervention group and from 8 to 5 in the control group. The additional intervention with LLIN covers for water containers showed a significant reduction in pupae per person index (PPI) (p=0.01). In the intervention group, the PPI index showed a clear decline of 71% compared with 25% in the control group. Costs were high but options for cost savings were identified. Short term impact evaluation indicates that the intervention package can reduce dengue vector density but sustained effect will depend on multiple factors. © The author 2015. The World Health Organization has granted Oxford University Press permission for the reproduction of this article.

  17. FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Air flow analysis II; 1999 nendo gakujutsu koenkai gaiyo. Kiryu kaiseki 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-05

    B-4 reported the result on particle size distribution experiment and numerical calculation with FEM and {kappa}- {epsilon} model using a welding simulation equipment for generation and removal of welding fume in a narrow site. Discussion was held on the position of an exhaust hood. B-5 reported the study results on indoor air flow conditions derived from a movable nozzle air conditioning system by model experiment and numerical analysis. Disagreement of both results between the experiment and calculation in the case of two diffusing nozzles attached at 30 degrees toward the inside was improved by shortening a sampling time for calculation. B-6 reported the study results on some parameters such as wind velocity, flow rate and inlet position, and the energy saving effect of an air curtain (wall outlet, floor inlet) to control air conditioning areas for a part of large spaces by numerical analysis of air flow. Discussion was held on calculation of 2-D flow and layered flow. B-7 is the 5th research report on measurement of air flow conditions such as measurement of large space environment by video camera and balloon. Study on the camera for automatic measurement, and the identification technique of balloon positions was reported. (translated by NEDO)

  18. Radiative and conductive heat transfer in a nongrey semitransparent medium. Application to fire protection curtains

    Energy Technology Data Exchange (ETDEWEB)

    Berour, Nacer; Lacroix, David E-mail: david.lacroix@lemta.uhp-nancy.fr; Boulet, Pascal; Jeandel, Gerard

    2004-06-01

    This paper deals with heat transfer in nongrey media which scatter, absorb and emit radiation. Considering a two dimensional geometry, radiative and conductive phenomena through the medium have been taken into account. The radiative part of the problem was solved using the discrete ordinate method with classical S{sub n} quadratures. The absorption and scattering coefficients involved in the radiative transfer equation (RTE) were obtained from the Mie theory. Conduction inside the medium was linked to the RTE through the energy conservation. Validation of the model has been achieved with several simulation of water spray curtains used as fire protection walls.

  19. The development of substitute inks and controls for reducing workplace concentrations of organic solvent vapors in a vinyl shower curtain printing plant.

    Science.gov (United States)

    Piltingsrud, Harley V; Zimmer, Anthony T; Rourke, Aaron B

    2003-08-01

    During the summer of 1994, football players at a practice field reported noxious odors in the area. Ohio Environmental Protection Agency (OEPA) investigations of industries surrounding the field included a printing facility producing vinyl shower curtains with screen-printed designs. Though not the source of the odor, they were discharging volatile organic compounds directly to the environs in violation of OEPA regulations. To achieve compliance they installed a catalytic oxidizer for treating discharged air. Due to high equipment costs, the capacity of the installed catalytic oxidizer resulted in a substantial reduction in discharged air flow rates and increased solvent vapor concentrations within the workplace. Vapor levels caused worker discomfort, prompting a request for assistance from the Ohio Bureau of Workers Compensation. The vapor concentrations were found to exceed NIOSH, OSHA, and ACGIH acceptable exposure levels. The workers were then required to wear organic vapor removing respirators full-time while printing as a temporary protective measure. The company requested NIOSH assistance in finding methods to reduce solvent vapor concentrations. NIOSH studies included the identification of the sources and relative magnitude of solvent emissions from the printing process, the design of controls for the emissions, and the development of substitute inks using non-photochemically reactive solvents. The new ink system and controls allowed OEPA removal of the requirement for the treatment of discharged air and substantial increases in dilution ventilation. Increased ventilation would permit reduction in worker exposures to less than 1/3 mixture TLV levels and removal of requirements for respirator usage. This solution was the result of a comprehensive review of all facets of the problem, including OEPA regulations. It also required cooperative work between the company and federal, state, and local governmental agencies.

  20. 多向可调节柔性连接式石材幕墙施工技术%Multi Direction Adjustable Connection Stone Curtain Wall Construction Technology

    Institute of Scientific and Technical Information of China (English)

    杨军

    2016-01-01

    This paper introduces a new type of surface stone curtain wall construction technology, the technology used to adjust the flexible back bolt of the multi direction can be adjusted, improved the construction efficiency of special⁃shaped curved surface stone, irregular curved surface stone curtain wall facade effect can be better.%介绍了一种新的异形曲面石材幕墙施工技术,该技术运用多向可调节柔性背栓的多向可调节性,提高了异形曲面石材的施工效率,异形曲面石材幕墙的外立面效果得以更好呈现。

  1. Evidence for Ventilation through Collective Respiratory Movements in Giant Honeybee (Apis dorsata) Nests.

    Science.gov (United States)

    Kastberger, Gerald; Waddoup, Dominique; Weihmann, Frank; Hoetzl, Thomas

    2016-01-01

    The Asian giant honeybees (Apis dorsata) build single-comb nests in the open, which makes this species particularly susceptible to environmental strains. Long-term infrared (IR) records documented cool nest regions (CNR) at the bee curtain (nCNR = 207, nnests > 20) distinguished by marked negative gradients (ΔTCNR/d 0) displaying the Venturi effect, which evidences funnel properties of CNRs. The air flows inwards through CNRs, which is verified by the negative spatial gradient ΔTCNR/d, by the positive grading of TCNR with Tamb and lastly by fanners which have directed their abdomens towards CNRs. Rare cases of RAT +0.4 cm2/s) displaying "inhalation" and "exhalation" cycling. "Inhalation" could be boosted by bees at the inner curtain layers, which stretch their extremities against the comb enlarging the inner nest lumen and thus causing a pressure fall which drives ambient air inwards through CNR funnels. The relaxing of the formerly "activated" bees could then trigger the "exhalation" process, which brings the bee curtain, passively by gravity, close to the comb again. That way, warm, CO2-enriched nest-borne air is pressed outwards through the leaking mesh of the bee curtain. This ventilation hypothesis is supported by IR imaging and laser vibrometry depicting CNRs in at least four aspects as low-resistance convection funnels for maintaining thermoregulation and restoring fresh air in the nest.

  2. Evidence for Ventilation through Collective Respiratory Movements in Giant Honeybee (Apis dorsata Nests.

    Directory of Open Access Journals (Sweden)

    Gerald Kastberger

    Full Text Available The Asian giant honeybees (Apis dorsata build single-comb nests in the open, which makes this species particularly susceptible to environmental strains. Long-term infrared (IR records documented cool nest regions (CNR at the bee curtain (nCNR = 207, nnests > 20 distinguished by marked negative gradients (ΔTCNR/d 0 displaying the Venturi effect, which evidences funnel properties of CNRs. The air flows inwards through CNRs, which is verified by the negative spatial gradient ΔTCNR/d, by the positive grading of TCNR with Tamb and lastly by fanners which have directed their abdomens towards CNRs. Rare cases of RAT +0.4 cm2/s displaying "inhalation" and "exhalation" cycling. "Inhalation" could be boosted by bees at the inner curtain layers, which stretch their extremities against the comb enlarging the inner nest lumen and thus causing a pressure fall which drives ambient air inwards through CNR funnels. The relaxing of the formerly "activated" bees could then trigger the "exhalation" process, which brings the bee curtain, passively by gravity, close to the comb again. That way, warm, CO2-enriched nest-borne air is pressed outwards through the leaking mesh of the bee curtain. This ventilation hypothesis is supported by IR imaging and laser vibrometry depicting CNRs in at least four aspects as low-resistance convection funnels for maintaining thermoregulation and restoring fresh air in the nest.

  3. Towards a Casa Segura: A Consumer Product Study of the Effect of Insecticide-Treated Curtains on Aedes aegypti and Dengue Virus Infections in the Home

    Science.gov (United States)

    Loroño-Pino, María Alba; García-Rejón, Julián E.; Machain-Williams, Carlos; Gomez-Carro, Salvador; Nuñez-Ayala, Guadalupe; del Rosario Nájera-Vázquez, Maria; Losoya, Arturo; Aguilar, Lyla; Saavedra-Rodriguez, Karla; Lozano-Fuentes, Saul; Beaty, Meaghan K.; Black, William C.; Keefe, Thomas J.; Eisen, Lars; Beaty, Barry J.

    2013-01-01

    The home, or domicile, is the principal environment for transmission of dengue virus (DENV) between humans and mosquito vectors. Community-wide distribution of insecticide-treated curtains (ITCs), mimicking vector control program-driven interventions, has shown promise to reduce DENV infections. We conducted a Casa Segura consumer product intervention study in Mérida, Mexico to determine the potential to reduce intradomicillary DENV transmission through ITC use in individual homes. Dengue virus infections in mosquitoes and in humans were reduced in homes with ITCs in one of two study subareas. Overall, ITCs reduced intradomicillary DENV transmission; ITC homes were significantly less likely to experience multiple DENV infections in humans than NTC homes. Dengue virus–infected Aedes aegypti females were reduced within the ITC homes where curtain use was highest. Some homes yielded up to nine infected Ae. aegypti females. This study provides insights regarding best practices for Casa Segura interventions to protect homes from intradomicillary DENV transmission. PMID:23732254

  4. Mathematical model for heat loss calculation through a window; Modelo para el calculo de la perdida de calor por una ventana

    Energy Technology Data Exchange (ETDEWEB)

    Fissore Sch, Adelqui; Cuevas B, Cristian [Universidad de Concepcion (Chile). Facultad de Ingenieria. Dept. de Ingenieria Mecanica]. E-mail: afissore@udec.cl; ccuevas@udec.cl

    2000-07-01

    In the present work a semi-empirical model for heat loss by convection at an indoor window surface with curtain or blind is given. With this model, the convection heat transfer coefficient and temperature of the air at confined space between the curtain and the glass can be calculated. The curtain was modeled with a paper due to the low thermal inertia that it has. The model is based on experimental data obtained for four separations between the paper and the window. Data from numerical simulation program are also used. (author)

  5. Concept and construction process of the ceramic curtain of Vila-real Library

    Directory of Open Access Journals (Sweden)

    A. Peñín Llobell

    2016-12-01

    Full Text Available The construction of the Library of Vila-real, selected in 2012 in the VIII Latin American Biennial of Architecture and Urbanism, highlights the importance of collaboration with industry for the development and application of its outer membrane. The analysis of the construction process of the ceramic cylindrical curtain that defines it, performed by white glazed ceramic, 5 cm diameter and 7.5 m height, reveals this fact. The system builds an interstitial space, essential for its use and environmental integration. At the same time it links the building to both local industrial fabric, which aims to establish itself as one of its exponents, and to the Mediterranean culture of filters. The procedure followed is ascribed to the postartesanal and pragmatic perspective that beyond the modern heroes, introduced characters like Jean Prouvé and that today, we state, should find natural and legal channels for its development, on behalf of the progress of the construction sector.

  6. FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Air conditioning systems for various facilities; 1999 nendo gakujutsu koenkai gaiyo. Kakushu shisetsu kucho system

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K. [Takenaka Corp., Osaka (Japan)

    1999-12-05

    B-49 reported the outline of an artificial weather room composed of one inner room and two outer rooms, and its temperature change and temperature profiles during air conditioning. The room is scheduled to be used for evaluation of air conditioning systems, thermal performance evaluation of building materials and study on ventilation efficiency. B-50 reported the seasonal measurement results on thermal environment, and cooling and heating use patterns of living rooms and common spaces of 4 welfare homes for aged persons, and showed that room temperature difference in winter should be considered. Measurement data on facilities with floor heating were required. B-51 reported the experiment and numerical analysis results on thermal environment, draft sensation, condensation and radiation effect of patient bedrooms by using a full-scale 4-bed room model with a specific outlet developed for patient bedroom air conditioning. B-52 reported the outline of an air conditioning system for vegetable factories, and its performance evaluation result during cooling. The effect of blackout curtains and local air conditioning was reported. B-53 reported the comparison study result on air conditioning for animal breeding rooms by full-scale model experiment and numerical analysis. The line outlet + hanging wall + rack back exhaust system was most favorable from the viewpoint of temperature profile and prevention of pollutants from diffusion. (translated by NEDO)

  7. Bacteriological evaluation of a down-draught necropsy table ventilation system.

    Science.gov (United States)

    al-Wali, W; Kibbler, C C; McLaughlin, J E

    1993-08-01

    To evaluate the microbiological efficacy of a down-draught necropsy table ventilation system (which surrounds the cadaver with a "curtain" of air under continuous extraction) during post mortem procedures. Air sampling was carried out both in the presence and absence of staff and cadaver and during a full post mortem procedure, with functioning and non-functioning table air extraction. The penetration of the air "curtain" was also examined during the use of an oscillating bone saw by means of a tracer organism, Bacillus subtilis var niger, painted on to the skull. There was little difference between bacterial counts obtained in the presence of staff only, staff plus cadaver, or during a post mortem examination. With all counts obtained, however, there was a two to three-fold reduction when the ventilation was in operation compared with when the extract duct was occluded. Using the tracer organism, a two to three log reduction in counts was shown when the "curtain" was in operation during the use of the oscillating bone saw. These results suggest that the system provides potential protection for post mortem room staff against airborne infections.

  8. Determination of the stresses and displacements in the cut off curtain body executed by the > method

    International Nuclear Information System (INIS)

    Snisarenko, V.I.; Mel'nikov, A.I.

    1994-01-01

    Construction of the cut-off-curtain (COC) is analyzed as a possible variant to reduce the rate of radioactive horizontal migration. Such constructions can be executed by the > method. The theoretical analysis of the stress-strained state of the carried out using the methods of the theory of elasticity and of the limit equilibrium of the strewing medium. Theoretical dependences are obtained and formulas for practical calculations of the COC-body stress-strained state in the depth intervals which are of practical interest are suggested. The dependences obtained may be used to calculate the consolidation parameters and filtration coefficients, to choose materials for the COC body, geometrical size and film elements included

  9. Between East and West: polio vaccination across the Iron Curtain in Cold War Hungary.

    Science.gov (United States)

    Vargha, Dora

    2014-01-01

    In 1950s Hungary, with an economy and infrastructure still devastated from World War II and facing further hardships, thousands of children became permanently disabled and many died in the severe polio epidemic that shook the globe. The relatively new communist regime invested significantly in solving the public health crisis, initially importing a vaccine from the West and later turning to the East for a new solution. Through the history of polio vaccination in Hungary, this article shows how Cold War politics shaped vaccine evaluation and implementation in the 1950s. On the one hand, the threat of polio created a safe place for hitherto unprecedented, open cooperation among governments and scientific communities on the two sides of the Iron Curtain. On the other hand, Cold War rhetoric influenced scientific evaluation of vaccines, choices of disease prevention, and ultimately the eradication of polio.

  10. Cost of intensive routine control and incremental cost of insecticide-treated curtain deployment in a setting with low Aedes aegypti infestation

    Directory of Open Access Journals (Sweden)

    Alberto Baly

    Full Text Available Abstract: INTRODUCTION Information regarding the cost of implementing insecticide-treated curtains (ITCs is scarce. Therefore, we evaluated the ITC implementation cost, in addition to the costs of intensive conventional routine activities of the Aedes control program in the city of Guantanamo, Cuba. METHODS A cost-analysis study was conducted from the perspective of the Aedes control program, nested in an ITC effectiveness trial, during 2009-2010. Data for this study were obtained from bookkeeping records and activity registers of the Provincial Aedes Control Programme Unit and the account records of the ITC trial. RESULTS The annual cost of the routine Aedes control program activities was US$16.80 per household (p.h. Among 3,015 households, 6,714 ITCs were distributed. The total average cost per ITC distributed was US$3.42, and 74.3% of this cost was attributed to the cost of purchasing the ITCs. The annualized costs p.h. of ITC implementation was US$3.80. The additional annualized cost for deploying ITCs represented 19% and 48.4% of the total cost of the routine Aedes control and adult-stage Aedes control programs, respectively. The trial did not lead to further reductions in the already relatively low Aedes infestation levels. CONCLUSIONS At current curtain prices, ITC deployment can hardly be considered an efficient option in Guantanamo and other comparable environments.

  11. Cost of intensive routine control and incremental cost of insecticide-treated curtain deployment in a setting with low Aedes aegypti infestation.

    Science.gov (United States)

    Baly, Alberto; Toledo, Maria Eugenia; Lambert, Isora; Benítez, Elizabeth; Rodriguez, Karina; Rodriguez, Esther; Vanlerberghe, Veerle; Stuyft, Patrick Van der

    2016-01-01

    Information regarding the cost of implementing insecticide-treated curtains (ITCs) is scarce. Therefore, we evaluated the ITC implementation cost, in addition to the costs of intensive conventional routine activities of the Aedes control program in the city of Guantanamo, Cuba. A cost-analysis study was conducted from the perspective of the Aedes control program, nested in an ITC effectiveness trial, during 2009-2010. Data for this study were obtained from bookkeeping records and activity registers of the Provincial Aedes Control Programme Unit and the account records of the ITC trial. The annual cost of the routine Aedes control program activities was US$16.80 per household (p.h). Among 3,015 households, 6,714 ITCs were distributed. The total average cost per ITC distributed was US$3.42, and 74.3% of this cost was attributed to the cost of purchasing the ITCs. The annualized costs p.h. of ITC implementation was US$3.80. The additional annualized cost for deploying ITCs represented 19% and 48.4% of the total cost of the routine Aedes control and adult-stage Aedes control programs, respectively. The trial did not lead to further reductions in the already relatively low Aedes infestation levels. At current curtain prices, ITC deployment can hardly be considered an efficient option in Guantanamo and other comparable environments.

  12. An air quality assessment onboard an Oberon class submarine : HMCS Okanagan

    International Nuclear Information System (INIS)

    Severs, Y.D.; Sabiston, B.H.

    2000-09-01

    The Defence and Civil Institute of Environmental Medicine (DCIEM) re-examined the air quality on an Oberon class submarine, the HMCS Okanagan, to determine if the atmosphere complied with Air Purification Standard BR 1326. The main objective of the assessment was to help in the development of future submarine air quality management. The information obtained from the Oberon class submarine could be readily applied to the Victoria class submarines. The assessment involved a trial aboard an Oberon under patrol conditions. The functional and detection capabilities of analytical air monitoring instruments were assessed for a 24-hour period to obtain data regarding the contaminants onboard the submarine. A profile of carbon dioxide accumulation and oxygen consumption was determined. This was followed by an assessment of the effectiveness of air purification such as carbon dioxide scrubbing, oxygen generation and snorting. Carbon monoxide was also monitored and carboxyhemoglobin was measured in both smokers and non-smokers. In order to determine if the sanitary or electrical systems, or engine exhaust posed any danger, ammonia, ozone and nitrous compounds were also measured. In addition, hydrogen, arsine and stibene were monitored to determine any possible danger from charging batteries. The health risks associated with aerosolized particles from cooking, smoking and exhaust gases were also measured. Results showed that all contaminants were within allowable limits. However, the study also confirmed that air purification measures on diesel submarines are minimal and poorly placed and that there is a lack of exhaust ventilation. Poor air exchange was worsened by compartmentalization and blackout curtains. Several recommendations were proposed to improve the management of air quality in Victoria class submarines. 18 refs., 2 tabs., 5 figs

  13. An air quality assessment onboard an Oberon class submarine : HMCS Okanagan

    Energy Technology Data Exchange (ETDEWEB)

    Severs, Y.D.; Sabiston, B.H.

    2000-09-01

    The Defence and Civil Institute of Environmental Medicine (DCIEM) re-examined the air quality on an Oberon class submarine, the HMCS Okanagan, to determine if the atmosphere complied with Air Purification Standard BR 1326. The main objective of the assessment was to help in the development of future submarine air quality management. The information obtained from the Oberon class submarine could be readily applied to the Victoria class submarines. The assessment involved a trial aboard an Oberon under patrol conditions. The functional and detection capabilities of analytical air monitoring instruments were assessed for a 24-hour period to obtain data regarding the contaminants onboard the submarine. A profile of carbon dioxide accumulation and oxygen consumption was determined. This was followed by an assessment of the effectiveness of air purification such as carbon dioxide scrubbing, oxygen generation and snorting. Carbon monoxide was also monitored and carboxyhemoglobin was measured in both smokers and non-smokers. In order to determine if the sanitary or electrical systems, or engine exhaust posed any danger, ammonia, ozone and nitrous compounds were also measured. In addition, hydrogen, arsine and stibene were monitored to determine any possible danger from charging batteries. The health risks associated with aerosolized particles from cooking, smoking and exhaust gases were also measured. Results showed that all contaminants were within allowable limits. However, the study also confirmed that air purification measures on diesel submarines are minimal and poorly placed and that there is a lack of exhaust ventilation. Poor air exchange was worsened by compartmentalization and blackout curtains. Several recommendations were proposed to improve the management of air quality in Victoria class submarines. 18 refs., 2 tabs., 5 figs.

  14. Parachute diverts ventilation fast

    Energy Technology Data Exchange (ETDEWEB)

    Chironis, N.P.

    1990-02-01

    The USBM Pittsburgh Research Center is developing a simple, inexpensive and highly effective new technique for keeping smoke and toxic gases out of intake escapeways during mine fires. The technique involves the use of a special parachute which fixes onto a roof bolt plate or strap, and is automatically inflated by incoming air. The chute thus becomes a quick-erect check curtain which leaks much less than conventional curtains. The air pressure in the intake quickly climbs, making it unlikely that any smoke from an adjacent entry would be able to migrate into the intake. 2 figs.

  15. Analysis of air return alternatives for CRS-type open volumetric receiver

    International Nuclear Information System (INIS)

    Marcos, Ma. Jesus; Romero, Manuel; Palero, Silvia

    2004-01-01

    Even though air-cooled receivers provide substantial benefits, such as low inertia and quick sun-following dispatchability, and the volumetric effect leads to designs with aperture areas similar to those used in molten salt or water/steam receivers, some concern persists regarding absorber durability, reduction of radiation losses and improvement of the air return ratio (ARR). The paper focuses on this last issue, since the ARR is a source of significant receiver losses in current designs. Today's scaled-up receivers claim values between 45 and 70% for ARR, which means, in terms of energy loss, between 5 and 15%. As a consequence of ARR and the radiation loss stemming from high working temperatures, open volumetric receivers efficiencies below 75% are reported at temperatures usable by the power block. Those values may be acceptable for a first demonstration plant, but are categorically not competitive for commercial schemes in which receiver efficiency should approach 90%. This paper discusses the impact of several geometrical properties of the absorber and air injection system used. The study was performed by CFD with the FLUENT code. The assessment considered such alternatives as modularity of the air return system (HITREC receiver concept), outer ring injection with air curtain effect or cavity aperture (with and without secondary concentrator). A detailed analysis reveals that some parts of the receiver aperture achieve an ARR above 90% at well-selected operating conditions, but average values hardly surpass 70%. Therefore, a careful design should keep in mind important variables such as the effects of receiver edge and lateral wind, as well as air injection angle

  16. Physical modeling of steel flow in a tun dish equipped with a turbulence inhibitor and a gas curtain; Modelacion fisica del flujo de acero en un distribuidor de colada continua equipado con un inhibidor de turbulencia y una cortina de gas

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Labra, M.; Diaz-Cruz, M.; Palafox-Ramos, J.; Avila-Davila, E. O.; Patino-Cardona, F.

    2005-07-01

    A 2/5 scale model with a transparent plastic sheet was built based on Froude criterion in which eight cases were studied by PIV technique, maintaining a constant gas flow rate of 596 ml/min and only varying the gas curtain position. The results permitted to get Residence Time Distribution (RTD) curves, and from the data processing it was found that combining Turbulence Inhibitor (TI) with the adequate gas curtain position it is enhanced the plug volume. The case VII presented the best results increasing the plug volume in 131.85% in comparison with the case IV which was taken as the reference one. (Author) 10 refs.

  17. 地铁深基坑工程抗突涌准幕灌浆技术研究%Study on Curtain Grouting Technology for Preventing Water Gushing in Works of Metro Deep Foundation Pit

    Institute of Scientific and Technical Information of China (English)

    郭宏宇

    2012-01-01

    杭州某地铁深基坑工程由于地连墙在圆砾层中成槽困难,使得地下连续墙(以下简称“地连墙”)插入深度减小,不能满足承压水抗突涌稳定性要求,基于此,依托该地铁深基坑实例,通过现场灌浆对比试验,确定帷幕灌浆参数,并按此参数设置帷幕灌浆,填充地连墙未隔断的圆砾层,与地连墙搭接形成封闭的阻水帷幕,解决承压水抗突涌问题。研究表明:圆砾层的孔隙度大、渗透性好,可进行灌浆处理;帷幕灌浆能够节省工期,节约造价,有效地解决圆砾层的承压水抗突涌问题。%Some difficulties occurred in trough work in the round gravel layer for metro deep foundation pit with floor- wall transition make the floor-wall insert depth reduced, therefore it can not meet the requirements on the stability under the pressure of water gushing. Based on these and by taking a metro deep fbundation pit as an instance, curtain grouting parameters are determined after the cornparison tests on the field grouting. The parameter is set to guide curtain grouting, fill the floor-wall no- separated gravel layer, and to form a closed water-blocking curtain of the floor-wall overlap to solve the problems occurred in pressure water to stop water gushing. The study shows that the satisfactory round gravel porosity and permeability help grouting treatment; and curtain grouting shortens construction duration with less cost, effectively providing gravel layers some solutions on pressure water preventing-gushing issues.

  18. Glass vitrification furnace

    International Nuclear Information System (INIS)

    Shirato, Katsuyuki.

    1995-01-01

    An air curtain is formed in the inside of an off gas exhaustion pipe, and off gases are ventilated therein in a state being isolated from the inner walls of the exhaustion pipe. In this case, a steam blowing port is disposed to the end portion of a suction side of an inner pipe to which the air curtain is formed, and a steam blowing means is disposed while being connected to the steam blowing port for sending steams. With such a constitution, since steams are condensed to extremely reduce the volume thereof, the amount of off gases to be processed in an off gas processing step at downstream can be reduced. (T.M.)

  19. Frost protection for atmospheric cooling tower

    International Nuclear Information System (INIS)

    Legrand, G.

    1987-01-01

    When the atmospheric temperature is near or lower than zero it is necessary to reduce the air flow entering in a cooling tower. A wire netting mounted on the air inlet is sprinkled with cold water. The level of the ice curtain and consequently the air flow is regulated by aspersion by hot water [fr

  20. Use of geostatistics on broiler production for evaluation of different minimum ventilation systems during brooding phase

    Directory of Open Access Journals (Sweden)

    Thayla Morandi Ridolfi de Carvalho

    2012-01-01

    Full Text Available The objective of this research was to evaluate different minimum ventilation systems, in relation to air quality and thermal comfort using geostatistics in brooding phase. The minimum ventilation systems were: Blue House I: exhaust fans + curtain management (end of the building; Blue House II: exhaust fans + side curtain management; and Dark House: exhaust fans + flag. The climate variables evaluated were: dry bulb temperature, relative humidity, air velocity, carbon dioxide and ammonia concentration, during winter time, at 9 a.m., in 80 equidistant points in brooding area. Data were evaluated by geostatistic technique. The results indicate that Wider broiler houses (above 15.0 m width present the greatest ammonia and humidity concentration. Blue House II present the best results in relation to air quality. However, none of the studied broiler houses present an ideal thermal comfort.

  1. Maintenance and Durability of the Concrete External Layer of Curtain Walls in Prefabricated Technological Poznan Large Panel System

    Science.gov (United States)

    Jasiczak, Józef; Girus, Krzysztof

    2017-10-01

    The issue of usability and durability of large-panel building constructed several decades ago is a subject of an in-depth analysis of many domestic and foreign investments. When considering the durability of specific large-panel system, one should consider, among others, the process of making external walls. The long-term and direct impact of weather conditions on the external layer of curtain walls is significant for the durability of large-panel buildings. For the needs of the presented paper, in 2016, the survey of cracks and a series of other tests of large-panel façade, residential building constructed in 1986, in Poland, in the PLP process system - Rataje was executed. Several hundred large-size, triple-layer curtain-wall slab with a 6-cm, concrete exterior cladding layer anchored using pins and hangers with the load-bearing layer, a 9-cm insulation layer made of mineral wool, and a 21-cm structural layer were surveyed. Significant deviations in thicknesses of particular wall layers were proven. Other significant damages and defects of external layers were found. At the second stage, many tests, both nondestructive and destructive, were conducted. They involved determining mechanical properties of an external layer. The concrete thickness was measured using with a type N Schmidt sclerometer and core samples were taken from this layer in order to mark concrete’s compressive strength. The range of carbonation (by phenolphthalein method) and the actual location and condition of reinforcement were estimated using a ferromagnetic device to determine the condition of the external layer. The diagnosis conducted in such a manner was the verification of necessary repair of the walls and their thermal efficiency improvement while ensuring safe conditions of their operation and modern functional and utility requirements. It should be also emphasized that the method of diagnosing the external walls presented in this paper may be popularized when evaluating such

  2. The nuclear waste disaster. A view behind the curtain of the presumably clean nuclear power; Das Atommuell-Desaster. Blicke hinter die Kulissen der angeblich sauberen Atomenergie

    Energy Technology Data Exchange (ETDEWEB)

    Schumacher, Julia; Simon, Armin; Stay, Jochen (comps.)

    2015-04-15

    The brochure on the nuclear waste disaster - a view behind the curtain of the presumably clean nuclear power discusses the following topics: Thuringia and Saxony - radiating landscapes, Gronau - 100.000 tons for eternity, Gundremmingen - nuclear waste records and castor shortage, Brunsbuettel - castor storage facility without licensing, Juelich the pebble bed drama, Karlsruhe - the hall is filled, Obrigheim - radioactive waste for cooking pots, Asse - the ticking bomb, final repositories - an illusion without solution, stop the waste production, Germany - endless nuclear waste.

  3. Aggressive Adenoid Cystic Carcinoma With Asymptomatic Spinal Cord Compression Revealed By A “Curtain Sign”

    Directory of Open Access Journals (Sweden)

    Martin Housset

    2008-08-01

    Full Text Available The author presents a case with an unusually aggressive evolution of an adenoid cystic carcinoma of the head and neck. The patient presented with sciatica one year after initial diagnosis. She was otherwise asymptomatic. Complete work-up for bone involvement, included bone scan and MRI. The patient had asymptomatic thoracic (T5 vertebral metastasis revealed by a typical curtain sign on MRI. She benefited from radiotherapy and did not develop respiratory distress, paraplegia or pain but died of other metastases.

  4. Density-dependent clustering: I. Pulling back the curtains on motions of the BAO peak

    Science.gov (United States)

    Neyrinck, Mark C.; Szapudi, István; McCullagh, Nuala; Szalay, Alexander S.; Falck, Bridget; Wang, Jie

    2018-05-01

    The most common statistic used to analyze large-scale structure surveys is the correlation function, or power spectrum. Here, we show how `slicing' the correlation function on local density brings sensitivity to interesting non-Gaussian features in the large-scale structure, such as the expansion or contraction of baryon acoustic oscillations (BAO) according to the local density. The sliced correlation function measures the large-scale flows that smear out the BAO, instead of just correcting them as reconstruction algorithms do. Thus, we expect the sliced correlation function to be useful in constraining the growth factor, and modified gravity theories that involve the local density. Out of the studied cases, we find that the run of the BAO peak location with density is best revealed when slicing on a ˜40 h-1 Mpc filtered density. But slicing on a ˜100 h-1 Mpc filtered density may be most useful in distinguishing between underdense and overdense regions, whose BAO peaks are separated by a substantial ˜5 h-1 Mpc at z = 0. We also introduce `curtain plots' showing how local densities drive particle motions toward or away from each other over the course of an N-body simulation.

  5. Deposition of fine and ultrafine particles on indoor surface materials

    DEFF Research Database (Denmark)

    Afshari, Alireza; Reinhold, Claus

    2008-01-01

    -scale test chamber. Experiments took place in a 32 m3 chamber with walls and ceiling made of glass. Prior to each experiment the chamber was flushed with outdoor air to reach an initial particle concentration typical of indoor air in buildings with natural ventilation. The decay of particle concentrations...... The aim of this study was the experimental determination of particle deposition for both different particle size fractions and different indoor surface materials. The selected surface materials were glass, gypsum board, carpet, and curtain. These materials were tested vertically in a full...... was monitored. Seven particle size fractions were studied. These comprised ultrafine and fine particles. Deposition was higher on carpet and curtain than on glass and gypsum board. Particles ranging from 0.3 to 0.5 µm had the lowest deposition. This fraction also has the highest penetration and its indoor...

  6. Energy Supply System for Industrial Poultry Houses

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2016-04-01

    Full Text Available The gas engine driven carbon dioxide heat pump designed for providing the heat, cold and electricity for industrial poultry house is proposed. The scheme differs from the known by using recuperative heat exchanger installed between the exhaust air duct of poultry house and heat pump evaporator and the heat curtain installed on the air duct after the evaporator. The air coming into the poultry house after the regenerative heat exchanger is supplied to the heat pump gas cooler. The heat pump produces heat of the required parameters of the input air and water for watering of poultry, space heating, etc. Heat pump compressor is driven by gas engine (GPA, by natural gas or biogas. The part of the gas-piston engine heat is used for adjusting the optimal heat pump mode and for regeneration of the absorbent in an evaporative cooler. The proposed technical solution of the above scheme provides a higher COP of the heat pump. Installing of heat curtain does not require the use of non-freezing solution to prevent icing of the air outlet of heat pump evaporator. The latter allows producing, besides electric power and heat, still cold (with the use off the adsorption-refrigerating machine and provide drying air inlet evaporative cooler (if necessary.

  7. Preconceptual design for the electrostatic enclosure

    International Nuclear Information System (INIS)

    Meyer, L.C.

    1992-09-01

    This report presents a preconceptual design (design criteria and assumptions) for electrostatic enclosures to be used during buried transuranic waste recovery operations. These electrostatic enclosures (along with the application of dust control products) will provide an in-depth contamination control strategy. As part of this preconceptual design, options for electrostatic curtain design are given including both hardwall and fabric enclosures. Ventilation systems, doors, air locks, electrostatic curtains, and supporting systems also are discussed. In addition to the conceptual design, engineering scale tests are proposed to be run at the Test Reactor Area. The planned engineering scale tests will give final material specifications for full-scale retrieval demonstrations

  8. Performance experiment on spray atomization and droplets deposition of wind-curtain electrostatic boom spray%风幕式静电喷杆喷雾喷头雾化与雾滴沉积性能试验

    Institute of Scientific and Technical Information of China (English)

    贾卫东; 胡化超; 陈龙; 陈志刚; 魏新华

    2015-01-01

    To solve the problem of less liquid deposition on the middle and lower plant canopy and uneven distribution of particle diameter by traditional pesticide application methods, this paper conducted the exploratory research about the application of the technology of pneumatic auxiliary spray combined with electrostatic spray. The charge-to-mass ratios of the droplets under different spray pressures and voltages were measured by measurement system. The results indicated that the charge-to-mass ratio increased as the voltage increased and then tended to be stable, yet decreased with the increase of spray pressure. The particle diameter spatial distribution of the droplets under charging or not was measured by Winner318B laser particle size analyzer;the horizontal and longitudinal stent in the system could move precisely so as to adjust the position of the nozzle relative to the measuring line of the laser particle size analyzer. The results showed that the volume median diameters (VMD) of the droplets decreased and then tended to increase when the nozzle moved from 0 to 3 in the horizontal stent; in the condition of no charging, the VMD of the droplets was 108.48μm and the coefficient of variation of droplet sizes was 11.96%, while in the condition of charging, the VMD of the droplets was 83.67μm and the coefficient of variation of droplet sizes was 7.48%;and the VMD of the droplets increased when the nozzle moved from 6 to 4 in the longitudinal stent. For analyzing the influence of wind-curtain, spray pressure and voltage on droplets deposition performance, the wind-curtain electrostatic boom spray system was set up and the experiment on droplet deposition performance was conducted. The system used cochineal solution as spraying liquid, and used radermachera hainanensis merr. as simulation target. Layout the film on the upper, middle, lower position plant canopy for collecting the droplets deposited. In order to ensure the accuracy of the experimental data, the

  9. Computerized simulations for indoor climate separation products; Computersimulaties voor klimaatscheidingsproducten

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, B.E. [Biddle, Kootstertille (Netherlands)

    2000-08-01

    This article discusses how climate separation works by using computer simulations. There is very good agreement between computer simulations and measurements in practice. The simulations can therefore be used as a tool in the development of comfort air curtains in the retail sector and in the development of air partitions in cold stores. Even so, practical measurements remain necessary in order to validate the simulations. 1 ref.

  10. Increasing the dust separation efficiency by water spray during the operation of coal combines

    Energy Technology Data Exchange (ETDEWEB)

    Feskov, M I; Kurdyukov, A N

    1974-08-01

    Possibilities of efficient wet dust separation around coal combines and their working members are described. The water consumption for dust separation around working members ranges from 0.3 to 1 l/cu m dust-laden air. The working member can be isolated from his surroundings by plastic walls or shields, while water or air curtains are rather unreliable. Such isolation requires a considerable increase in the water expenditure to improve the wettability of the coal particles by humidifying the air. Laboratory experiments revealed improved wettability and sedimentability of coal particles in humid air.

  11. Noise-proof bubbles to protect sea life

    International Nuclear Information System (INIS)

    Deboutte, G.

    2012-01-01

    The construction of wind turbines in shallow sea might jeopardize the life of mammals living nearby. The wave sound generated by each hammer impact to drive the pillars deep in the sea bottom can reach up to 200 decibels at 750 m away from the construction site. Repeated noises at this sound level is thought to be damaging for audition systems of sea mammals. The German authorities have launched a 4-year long program to find efficient technical solutions to damp sound waves. Various techniques have been tested in the Baltic sea and it appears that most techniques are efficient but some seem more relevant like the bubble curtain in which air bubbles generated around the site disturb the propagation of sound waves, or the balloon curtain in which air balloons plays the role of the bubbles, or the network of vertical pipes set around the construction site, or the sound-proofed sheath set around the pillar and hammer. (A.C.)

  12. Scientific Objectives of Small Carry-on Impactor (SCI) and Deployable Camera 3 Digital (DCAM3-D): Observation of an Ejecta Curtain and a Crater Formed on the Surface of Ryugu by an Artificial High-Velocity Impact

    Science.gov (United States)

    Arakawa, M.; Wada, K.; Saiki, T.; Kadono, T.; Takagi, Y.; Shirai, K.; Okamoto, C.; Yano, H.; Hayakawa, M.; Nakazawa, S.; Hirata, N.; Kobayashi, M.; Michel, P.; Jutzi, M.; Imamura, H.; Ogawa, K.; Sakatani, N.; Iijima, Y.; Honda, R.; Ishibashi, K.; Hayakawa, H.; Sawada, H.

    2017-07-01

    The Small Carry-on Impactor (SCI) equipped on Hayabusa2 was developed to produce an artificial impact crater on the primitive Near-Earth Asteroid (NEA) 162173 Ryugu (Ryugu) in order to explore the asteroid subsurface material unaffected by space weathering and thermal alteration by solar radiation. An exposed fresh surface by the impactor and/or the ejecta deposit excavated from the crater will be observed by remote sensing instruments, and a subsurface fresh sample of the asteroid will be collected there. The SCI impact experiment will be observed by a Deployable CAMera 3-D (DCAM3-D) at a distance of ˜1 km from the impact point, and the time evolution of the ejecta curtain will be observed by this camera to confirm the impact point on the asteroid surface. As a result of the observation of the ejecta curtain by DCAM3-D and the crater morphology by onboard cameras, the subsurface structure and the physical properties of the constituting materials will be derived from crater scaling laws. Moreover, the SCI experiment on Ryugu gives us a precious opportunity to clarify effects of microgravity on the cratering process and to validate numerical simulations and models of the cratering process.

  13. The Stars behind the Curtain

    Science.gov (United States)

    2010-02-01

    ESO is releasing a magnificent VLT image of the giant stellar nursery surrounding NGC 3603, in which stars are continuously being born. Embedded in this scenic nebula is one of the most luminous and most compact clusters of young, massive stars in our Milky Way, which therefore serves as an excellent "local" analogue of very active star-forming regions in other galaxies. The cluster also hosts the most massive star to be "weighed" so far. NGC 3603 is a starburst region: a cosmic factory where stars form frantically from the nebula's extended clouds of gas and dust. Located 22 000 light-years away from the Sun, it is the closest region of this kind known in our galaxy, providing astronomers with a local test bed for studying intense star formation processes, very common in other galaxies, but hard to observe in detail because of their great distance from us. The nebula owes its shape to the intense light and winds coming from the young, massive stars which lift the curtains of gas and clouds revealing a multitude of glowing suns. The central cluster of stars inside NGC 3603 harbours thousands of stars of all sorts (eso9946): the majority have masses similar to or less than that of our Sun, but most spectacular are several of the very massive stars that are close to the end of their lives. Several blue supergiant stars crowd into a volume of less than a cubic light-year, along with three so-called Wolf-Rayet stars - extremely bright and massive stars that are ejecting vast amounts of material before finishing off in glorious explosions known as supernovae. Using another recent set of observations performed with the SINFONI instrument on ESO's Very Large Telescope (VLT), astronomers have confirmed that one of these stars is about 120 times more massive than our Sun, standing out as the most massive star known so far in the Milky Way [1]. The clouds of NGC 3603 provide us with a family picture of stars in different stages of their life, with gaseous structures that are

  14. Integral Facade Construction. Towards a new product architecture for curtain walls

    Directory of Open Access Journals (Sweden)

    Tillmann Klein

    2013-06-01

    Full Text Available Curtain wall constructions are one of the most applied facade constructions today. Independently attached to the primary load bearing structure of the building they protect the building’s interior from external climate conditions and allow great design freedom. With continuously rising requirements in terms of energy savings the constructional principle has reached its limits and strategies for improvement are needed. Incrementally evolved over time it is closely related to the architectural design and building processes. Based on literature research and stakeholder interviews the dissertation maps out the traditional and craftsmanship related facade design and construction process currently employed. In a next step, future challenges for facade constructions to cope with a changing market environment are identified. A facade function tree is developed and the theory of product architecture is applied to create a comparative basis for analysing different historical and contemporary facade products and systems. The function tree as well as the analysis clearly show how the fragmented market structures has influenced contemporary facade construction and leads to extremely modular product architectures. Numerous case studies for a new approach are conducted and summarised in several matrices. The case studies show how different modular and integral constructional strategies can respond to the future challenges. The pros and cons of different facade solutions, their potential for innovation and robustness in terms of market conditions are investigated. The dissertation concludes that a greater diversity of fa.ade types with a more integral construction is needed to meet the sometimes conflicting future challenges. If this can be realised, a greater diversity of more integral design and construction processes will evolve simultaneously. The role of the different stakeholders will change and a new way of educating architects or facade specialists

  15. Simultaneous density-field visualization and PIV of the Richtmyer-Meshkov instability

    Science.gov (United States)

    Prestridge, Katherine; Rightley, Paul; Benjamin, Robert; Kurnit, Norman; Boxx, Isaac; Vorobieff, Peter

    1999-11-01

    We describe a highly-detailed experimental characterization of the Richtmyer-Meshkov instability. A vertical curtain of heavy gas (SF_6) flows into the test section of an air-filled, horizontal shock tube, and the instability evolves after the passage of a Mach 1.2 shock past the curtain. The evolution of the curtain is visualized by seeding the SF6 with small (d ≈ 0.5 μm) glycol/water droplets using a modified theatrical fog generator. Because the event lasts only 1 ms and the initial conditions vary from test to test, rapid and high-resolution (both spatial and temporal) data acquisition is required in order to characterize the initial and dynamic conditions for each experimental event. A customized, frequency-doubled, burst mode Nd:YAG laser and a commercial single-pulse laser are used for the implementation of simultaneous density-field imaging and PIV diagnostics. We have provided data about flow scaling and mixing through image analysis, and PIV data gives us further quantitative physical insight into the evolution of the Richtmyer-Meshkov instability.

  16. The Seated Soldier Study: Posture and Body Shape in Vehicle Seats

    Science.gov (United States)

    2013-10-31

    lasers in four towers arranged in a square create a line on the subject as they move synchronously from top to bottom. Two cameras on each of the four...of the scanner being assembled and the scanner draped with curtains to control light and provide privacy. UNCLASSIFIED UNCLASSIFIED 22 Figure 16...with special reference to the limbs. WADC Technical Report No. 55-159. Wright-Patterson Air Force Base, OH: Wright Air Development Center

  17. 76 FR 35744 - Amendments to National Emission Standards for Hazardous Air Pollutants for Area Sources: Plating...

    Science.gov (United States)

    2011-06-20

    ... Metal Valve and Pipe Fitting Manufacturing; 332999, All Other Miscellaneous Fabricated Metal Product... spraying operation and exhaust them to a water curtain, or a cartridge, fabric, or HEPA filter... from the thermal spraying operation and exhaust them to a cartridge, fabric, or HEPA filter...

  18. 40 CFR 60.1440 - What is yard waste?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is yard waste? 60.1440 Section 60...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste... Reconstruction is Commenced After June 6, 2001 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60...

  19. 76 FR 57913 - Amendments to National Emission Standards for Hazardous Air Pollutants for Area Sources: Plating...

    Science.gov (United States)

    2011-09-19

    ... Fixture Fitting and Trim Manufacturing; Other Metal Valve and Pipe Fitting Manufacturing; 332999, All... thermal spraying operation and exhaust them to a water curtain, or a cartridge, fabric, or HEPA filter... from the thermal spraying operation and exhaust them to a cartridge, fabric, or HEPA filter...

  20. 40 CFR 60.1915 - What is yard waste?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is yard waste? 60.1915 Section 60... Municipal Waste Combustion Units Constructed on or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1915 What is yard waste? Yard waste is grass, grass...

  1. 40 CFR 62.15370 - What is yard waste?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false What is yard waste? 62.15370 Section 62... for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15370 What is yard waste? Yard waste is grass, grass...

  2. 40 CFR 60.56b - Standards for air curtain incinerators.

    Science.gov (United States)

    2010-07-01

    ... the capacity to combust greater than 250 tons per day of municipal solid waste and that combusts a fuel feed stream composed of 100 percent yard waste and no other municipal solid waste materials shall... Municipal Waste Combustors for Which Construction is Commenced After September 20, 1994 or for Which...

  3. 40 CFR 62.14107 - Emission limits for air curtain incinerators.

    Science.gov (United States)

    2010-07-01

    ... and that combusts a fuel feed stream composed of 100 percent yard waste and no other municipal solid... level of up to 35 percent (6-minute average) is permitted during startup periods during the first 30...

  4. 40 CFR 60.2245 - What is an air curtain incinerator?

    Science.gov (United States)

    2010-07-01

    ... Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for....2260). (1) 100 percent wood waste. (2) 100 percent clean lumber. (3) 100 percent mixture of only wood...

  5. Use of electric and bubble barriers to limit the movement of Eurasian ruffe (Gymnocephalus cernuus)

    Science.gov (United States)

    Dawson, Heather A.; Reinhardt, Ulrich G.; Savino, Jacqueline F.

    2006-01-01

    Eurasian ruffe (Gymnocephalus cernuus) is an aquatic invasive species accidentally introduced via ballast water to the Great Lakes in the mid-1980s. Fish barrier technology is being studied to stop the spread of invasive fish species such as ruffe. Electrical barriers have been constructed, most notably in the Chicago Sanitary and Ship Canal, to prevent non-indigenous species such as ruffe from spreading into areas where they are currently absent. Information on the response of an invasive fish to barriers can help managers determine strategies to prevent the spread of these species via artificial waterways. In this laboratory study electrical barriers were set up to determine effectiveness of four electrical settings for repelling Eurasian ruffe measuring 10 cm or more in length. In separate tests, airbubble curtains with two bubble sizes and densities were created to test this type of barrier in blocking movement of ruffe less than 10 cm in length. The most effective electrical settings found (5 ms, 6 Hz) repelled only about half of the attempted passes. When ruffe were offered food or shelter on the opposite side of the electrical barrier, neither food-starved nor shelter-deprived ruffe made significantly more attempts to cross the barrier. Ruffe were significantly repelled by all air-bubble curtains, but a large proportion of passes (4.5 passes per fish on average in the treatments) were still observed. Electrical barrier settings and air-bubble curtains used in this study were found ineffective at completely blocking the movement, but somewhat effective at inhibiting the passage of ruffe.

  6. Chemical warfare protection for the cockpit of future aircraft

    Science.gov (United States)

    Pickl, William C.

    1988-01-01

    Currently systems are being developed which will filter chemical and biological contaminants from crew station air. In order to maximize the benefits of these systems, a method of keeping the cockpit contaminant free during pilot ingress and egress is needed. One solution is to use a rectangular plastic curtain to seal the four edges of the canopy frame to the canopy sill. The curtain is stored in a tray which is recessed into the canopy sill and unfolds in accordion fashion as the canopy is raised. A two way zipper developed by Calspan could be used as an airlock between the pilot's oversuit and the cockpit. This system eliminates the pilot's need for heavy and restrictive CB gear because he would never be exposed to the chemical warfare environment.

  7. Air & Space Power Journal. Volume 28, Number 5, September-October 2014

    Science.gov (United States)

    2014-10-01

    authorized could employ up to three four-ship cells concurrently.27 If three cells are employed simul- taneously, then 12 of the 21 jets (57 percent...of terrorist cells probably does not have the strategic capability to affect information to the degree required to sway global opinion. In the face...effect of additional weight on the mobility and stamina of the horses). The costly proposition of thickening the stone curtain walls of castles would

  8. USING A GERMICIDAL INSTALLATION TO IMPROVE THE ENVIRONMENTAL SITUATION AT A POULTRY FARM

    Directory of Open Access Journals (Sweden)

    T. L. Mayorova

    2016-01-01

    Full Text Available Aim. The aim is to study the effect of bactericidal installation in combination with a device for creating a water curtain on the microclimate in the poultry house and environment. Methods. Epizootic research was carried out according to "epizootic methodology", FGI «Federal Centre for Animal Health» (FGI «ARRIAH». Gas composition of air was investigated by means of universal gas-analyzer (UG-2; the content of carbon dioxide was measured by Subbotin-Nagorskiy titrimetric method; the amount of dust in the air was measured by a gravimetric (weight method. Air humidity was calculated by means of August statistical psychrometer. Evaluation of the microbial contamination of air was carried out using the Krotov’s device. Results. The performed studies before and after the air bactericidal purification in a poultry farm showed a reduction of carbon dioxide and ammonia by 2-2.5 times, the total microbial contamination of air by 1.9 times and the dust by 4.3 times. We found a direct link between the increases in the amount of microbial bodies of air depending on the age of the bird. Thus, after air-cleaning in the poultry house room where they kept 15-d-old chicks, we calculated 5 thousand microbial cells per one m3 found (E.coli, and at the age of 45 days, the level of contamination reached 11 thousand microbial bodies. Conclusion. Research in the poultry house reveals that using bactericidal installation paired with water curtain device can significantly reduce the concentration of gases, dust and microorganisms in the air of the house and decrease the release into the environment, which will undoubtedly have an impact on the ecological situation of the environment, animal and human health. 

  9. Effect of Vertical Shoot-Positioned, Scott-Henry, Geneva Double-Curtain, Arch-Cane, and Parral Training Systems on the Volatile Composition of Albariño Wines

    Directory of Open Access Journals (Sweden)

    Mar Vilanova

    2017-09-01

    Full Text Available Viticultural practices influence both grape and wine quality. The influence of training systems on volatile composition was investigated for Albariño wine from Rías Baixas AOC in Northwest Spain. The odoriferous contribution of the compounds to the wine aroma was also studied. Volatile compounds belonging to ten groups (alcohols, C6-compounds, ethyl esters, acetates, terpenols, C13-norisoprenoids, volatile phenols, volatile fatty acids, lactones and carbonyl compounds were determined in Albariño wines from different training systems, Vertical Shoot-Positioned (VSP, Scott-Henry (SH, Geneva Double-Curtain (GDC, Arch-Cane (AC, and Parral (P during 2010 and 2011 vintages. Wines from GDC showed the highest total volatile composition with the highest concentrations of alcohols, ethyl esters, fatty acids, and lactones families. However, the highest levels of terpenes and C13-norisoprenoids were quantified in the SH system. A fruitier aroma was observed in Albariño wines from GDC when odor activity values were calculated.

  10. Theoretical model for the UV disinfection system in the operating ward of PZU 'Filip Vtori'

    International Nuclear Information System (INIS)

    Ilkov, Marjan

    2010-01-01

    Here we investigate the theoretical modeling of an UV disinfection system for the operating ward in PZU 'FILIP VTORI'. As nocosomial infections pose a serious threat to patients everywhere in the world, here the disinfection of the air and the surfaces is modeled and discussed. The surfaces are disinfected with direct illumination of open UV after hours system, UV curtains, overhead disinfection, floor disinfection and disinfection of the incoming air through the ventilation/air-condition system. From the results it can be seen that the concentrations of bacteria, fungi and viruses drop significantly which in turn should give a significant drop in a number of hospital acquired infections.(Author)

  11. Using HIPPO Data for Formal and Informal Science Education

    Science.gov (United States)

    Rockwell, A.; Hatheway, B.; Zondlo, M. A.

    2012-12-01

    The HIAPER Pole-to-Pole Observations (HIPPO) field project recently concluded its mission to map greenhouse gases and black carbon from the Arctic to the Antarctic using the NSF/NCAR Gulfstream V. HIPPO resulted in visually-rich and easy-to-understand altitude/latitude curtain plots of several trace gases and black carbon, from five seasons during 2009-2011. The data and curtain plots are available for both formal and informal science education to support the instruction of atmospheric science and Earth systems. Middle and high school activities have been developed using these data and curtain plots, and an undergraduate course based on HIPPO data - Global Air Pollution - is offered at Princeton University. The visually stimulating curtain plots are unique in that a wide range of people can comprehend them because they provide an easy-to-understand picture of the global distribution of chemical species for non-scientists or beginning users, while also displaying valuable detailed information for the advanced viewer. The plots are a powerful graphical tool that can be used to communicate climate science because they illustrate the concepts of how trace gas distributions are linked to the large-scale dynamics of the Earth; show seasonal changes in distribution and concentrations; and use the same display format for each tracer. In order to connect people to the data, a multi-faceted and engaging public information program and supporting educational materials for HIPPO were developed. These provided a unique look into global field research and included social media platforms such as Facebook and Twitter; a range of videos from simple motion graphics to detailed narratives; both printed and online written materials; and mass-media publications.

  12. An experimental and numerical study on the improvement of the performance of Savonius wind rotor

    International Nuclear Information System (INIS)

    Altan, Burcin Deda; Atilgan, Mehmet

    2008-01-01

    In the present study, a curtain has been designed to increase the low performance of the Savonius wind rotor, a type of vertical-axis wind rotor, and the effect of this curtain on the static rotor performance has been analyzed both experimentally and numerically. Designed to prevent the torque that occurs on the convex blade of the rotor in the negative direction, this curtain has been placed in front of the rotor. Experimental measurements and numerical analysis have been conducted when the Savonius wind rotor is with and without curtain. The static torque values of the rotor have been measured by experiments and calculated by numerical analysis, and finally they have been compared. The best results have been obtained by means of the rotor with curtain. Low static torque values have been obtained with the short curtain dimensions, while a considerable increase has been acquired in the static torque values with the long curtain dimensions. Fluent 6.0 trade software has been used as the numerical method

  13. Determination of the stresses and displacements in the cut off curtain body executed by the << Wall-in-the ground >> method.; Opredelenie napryazhenij i peremeshchenij v tele protivofil`tratsionnoj zavesy, vypolnennoj metodom << stena v grunte >>.

    Energy Technology Data Exchange (ETDEWEB)

    Snisarenko, V I; Mel` nikov, A I [Myinyisterstvo Budyivel` noyi Arkhyitekturi, Kyiv (Ukraine); [Myizhgaluzevij Naukovo-Tekhnyichnij Tsentr ` ` Ukrittya ` ` , Natsyional` na Akademyiya Nauk Ukrayini, Chornobil` (Ukraine)

    1994-12-31

    Construction of the cut-off-curtain (COC) is analyzed as a possible variant to reduce the rate of radioactive horizontal migration. Such constructions can be executed by the << wall-in-the ground >> method. The theoretical analysis of the stress-strained state of the carried out using the methods of the theory of elasticity and of the limit equilibrium of the strewing medium. Theoretical dependences are obtained and formulas for practical calculations of the COC-body stress-strained state in the depth intervals which are of practical interest are suggested. The dependences obtained may be used to calculate the consolidation parameters and filtration coefficients, to choose materials for the COC body, geometrical size and film elements included.

  14. Aviary heating: control of air temperature heated by a set biomass gasifier-combustor in a co-current flow, using a frequency inverter; Aquecimento de aviarios: controle da temperatura do ar aquecido por um conjunto gaseificador-combustor de biomassa de fluxo concorrente, utilizando um inversor de frequencia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, William Rosario dos [Universidade Presidente Antonio Carlos (UNIPAC), Ponte Nova, MG (Brazil); Silva, Jadir Nogueira; Oliveira Filho, Delly; Martins, Marcio Aredes; Oliveira, Jofran Luiz de [Universidade Federal de Vicosa (UFV), MG (Brazil)], Emails: jadir@ufv.br, delly@ufv.br, aredes@ufv.br, jofran.oliveira@ufv.br

    2009-07-01

    One of the problems with using the gasifier for heating purposes in poultry facilities is the waste of energy during the day, once the equipment does not have control of the thermal and power generated. During this period, the difference in temperature between the air and the standard for the birds inside the building is lower than when compared with the nocturnal period. During the day, the temperature inside the poultry house is controlled by curtains, which occurs without diminishing the biomass burning. Another way to control the temperature is the shutdown of the system, which requires the constant attention of the operator. In this way, there is a potential for energy savings if the thermal power could be controlled according to the demand, which can be represented by the temperature gradient. The purpose of this study was to control the temperature of exhaustion air from a set combustor-gasifier (down draft), based on the model developed by Martin et al. (2006), through the control of speed of the fan engine and also controlling the flow contributions of primary and secondary air in the combustor. The experiment was carried out in the Energy and Pre-processing of Agricultural Products areas, at the Department of Agricultural Engineering - Federal University of Vicosa. (author)

  15. Surfacing Rescue Container Concept Design for Trident Submarines

    Science.gov (United States)

    2009-06-01

    insulation , synthetic seat cushions, electrical components and wiring, and the lubricants used in the ventilation and dewatering equipment. 24...lightweight, and small enough to be suspended between the LSRC pressure hull frames. An innovative variation of this product, manufactured by Micropore ... Micropore curtain, known as ExtendAirTM, comes in canisters approximately 7.5 inches tall with a diameter of 4.25 inches, each weighing about ten pounds

  16. Sub-lethal Ocular Trauma (SLOT): Establishing a Standardized Blast Threshold to Facilitate Diagnostic, Early Treatment, and Recovery Studies for Blast Injuries to the Eye and Optic Nerve

    Science.gov (United States)

    2013-09-01

    doors. Center: damage to the sensor mounts. Right: Damage to the blast curtain . Figure 6. US Army Institute of Surgical Research shock...for 5 min. The stained slides were placed on filter paper and air -dried for 5 min. Prior to starting the MALDI analysis, the sections were...internal scleral delaminations. Development of a rigorous experimental methodology and use of pre-blast ultrasound screening gave confidence that the

  17. Control of blast overpressure and vibrations at the Underground Research Laboratory

    International Nuclear Information System (INIS)

    Kuzyk, G.W.; Onagi, D.P.; Mohanty, B.

    1991-01-01

    AECL Research (AECL) has constructed an Underground Research Laboratory (URL) as a facility for research and development in the Canadian Nuclear Fuel Waste Management Program. The objectives of the program are to develop and evaluate the technology to ensure safe, permanent disposal of Canada's nuclear fuel waste. Several multidisciplinary experiments and engineering demonstrations are planned for the URL over the next ten years. In 1989, AECL excavated a test room for the Buffer/Container Experiment at the 240 Level. The blasts were designed to limit vibration and overpressure damage because the excavation was located close to existing furnishings and services that were very susceptible to blast-induced vibration and overpressure. An experimental room, which contained sensitive instrumentation, was located within 30 m of the initial blasts. A concrete floor slab, timber curtains and a bulkhead were installed to protect furnishings and services from fly-rock and overpressure. Five of the initial blasts were monitored. This paper describes the results of the monitoring program and the effectiveness of the blast design, floor slab and timber curtains and bulkhead in reducing blast overpressure and vibrations at the blast site. It is shown that greater than a 20-fold reduction in both blast vibrations and air overpressures can be achieved with specific combinations of blast design, installation of timber curtains and construction of a concrete floor slab

  18. A prospective birth cohort study of different risk factors for development of allergic diseases in offspring of non-atopic parents.

    Science.gov (United States)

    Lee, Ming-Tsung; Wu, Chih-Chiang; Ou, Chia-Yu; Chang, Jen-Chieh; Liu, Chieh-An; Wang, Chih-Lu; Chuang, Hau; Kuo, Ho-Chang; Hsu, Te-Yao; Chen, Chie-Pein; Yang, Kuender D

    2017-02-14

    Allergic diseases are thought to be inherited. Prevalence of allergic diseases has, however, increased dramatically in last decades, suggesting environmental causes for the development of allergic diseases. We studied risk factors associated with the development of atopic dermatitis (AD), allergic rhinitis (AR) and asthma (AS) in children of non-atopic parents in a subtropical country. In a birth cohort of 1,497 newborns, parents were prenatally enrolled and validated for allergic diseases by questionnaire, physician-verified and total or specific Immunoglobulin E (IgE) levels; 1,236 and 756 children, respectively, completed their 3-year and 6-year follow-up. Clinical examination, questionnaire, and blood samples for total and specific IgE of the children were collected at each follow-up visit. Prevalence of AD, AR and AS was, respectively, 8.2%, 30.8% and 12.4% in children of non-atopic parents. Prevalence of AR (pchildren of parents who were both atopic. A combination of Cesarean section (C/S) and breastfeeding for more than 1 month showed the highest risk for AD (OR=3.111, p=.006). Infants living in homes with curtains and no air filters had the highest risk for AR (OR=2.647, pparents living in homes without air filters had the highest risk for AS (OR=1.930, p=.039). Breastfeeding and C/S affect development of AD. Gender, use of curtains and/or air filters affect AR and AS, suggesting that control of the perinatal environment is necessary for the prevention of atopic diseases in children of non-atopic parents.

  19. Insecticide treated curtains and residual insecticide treatment to control Aedes aegypti: An acceptability study in Santiago de Cuba.

    Directory of Open Access Journals (Sweden)

    Dennis Pérez

    2018-01-01

    Full Text Available Within the context of a field trial conducted by the Cuban vector control program (AaCP, we assessed acceptability of insecticide-treated curtains (ITCs and residual insecticide treatment (RIT with deltamethrin by the community. We also assessed the potential influence of interviewees' risk perceptions for getting dengue and disease severity.We embedded a qualitative study using in-depth interviews in a cluster randomized trial (CRT testing the effectiveness of ITCs and RIT in Santiago de Cuba. In-depth interviews (N = 38 were conducted four and twelve months after deployment of the tools with people who accepted the tools, who stopped using them and who did not accept the tools. Data analysis was deductive. Main reasons for accepting ITCs at the start of the trial were perceived efficacy and not being harmful to health. Constraints linked to manufacturer instructions were the main reason for not using ITCs. People stopped using the ITCs due to perceived allergy, toxicity and low efficacy. Few heads of households refused RIT despite the noting reasons for rejection, such as allergy, health hazard and toxicity. Positive opinions of the vector control program influenced acceptability of both tools. However, frequent insecticide fogging as part of routine AaCP vector control actions diminished perceived efficacy of both tools and, therefore, acceptability. Fifty percent of interviewees did feel at risk for getting dengue and considered dengue a severe disease. However, this did not appear to influence acceptability of ITCs or RIT.Acceptability of ITCs and RIT was linked to acceptability of AaCP routine vector control activities. However, uptake and use were not always an indication of acceptability. Factors leading to acceptability may be best identified using qualitative methods, but more research is needed on the concept of acceptability and its measurement.

  20. Insecticide treated curtains and residual insecticide treatment to control Aedes aegypti: An acceptability study in Santiago de Cuba.

    Science.gov (United States)

    Pérez, Dennis; Van der Stuyft, Patrick; Toledo, María Eugenia; Ceballos, Enrique; Fabré, Francisco; Lefèvre, Pierre

    2018-01-01

    Within the context of a field trial conducted by the Cuban vector control program (AaCP), we assessed acceptability of insecticide-treated curtains (ITCs) and residual insecticide treatment (RIT) with deltamethrin by the community. We also assessed the potential influence of interviewees' risk perceptions for getting dengue and disease severity. We embedded a qualitative study using in-depth interviews in a cluster randomized trial (CRT) testing the effectiveness of ITCs and RIT in Santiago de Cuba. In-depth interviews (N = 38) were conducted four and twelve months after deployment of the tools with people who accepted the tools, who stopped using them and who did not accept the tools. Data analysis was deductive. Main reasons for accepting ITCs at the start of the trial were perceived efficacy and not being harmful to health. Constraints linked to manufacturer instructions were the main reason for not using ITCs. People stopped using the ITCs due to perceived allergy, toxicity and low efficacy. Few heads of households refused RIT despite the noting reasons for rejection, such as allergy, health hazard and toxicity. Positive opinions of the vector control program influenced acceptability of both tools. However, frequent insecticide fogging as part of routine AaCP vector control actions diminished perceived efficacy of both tools and, therefore, acceptability. Fifty percent of interviewees did feel at risk for getting dengue and considered dengue a severe disease. However, this did not appear to influence acceptability of ITCs or RIT. Acceptability of ITCs and RIT was linked to acceptability of AaCP routine vector control activities. However, uptake and use were not always an indication of acceptability. Factors leading to acceptability may be best identified using qualitative methods, but more research is needed on the concept of acceptability and its measurement.

  1. Isothermal model investigation of fume extraction systems for the scrap burner at Appleby Frodingham

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, D.

    1976-08-01

    Model tests have been made on three suggested schemes for improving the efficiency of fume collection on the scrap burning installation in the Anchor BOS plant at Appleby Frodingham. In particular the usefulness of air curtains as a means of containing the fume has been examined. CO/sub 2/ tracer measurements, and photographs using smoke for visualization have allowed the assessment of the collection efficiencies of the three schemes, and some alterative solutions have been investigated using similar methods. (GRA)

  2. Reducing the effects of eutrophication by aeration. Advantages of the application of this technique upstream in the Potable Water Treatment Plant; Reduccion por aireacion de los efectos de eutrofizacion. Ventajas de la aplicaciond e esta tecnica aguas arriba de las Estaciones de Tratamiento de Agua Potable

    Energy Technology Data Exchange (ETDEWEB)

    Saraiva de Aguilar, J. l.; Nunes, G.

    2004-07-01

    Several techniques are used to limit the progression of eutrophication in lakes and ponds, and to reduce its main negative effects. One of these techniques consists in maintaining oxidant conditions in deeper water layers of lakes and ponds, and, thus, to reduce or even prevent the release of harmful substances, which would result in higher water treatment costs. This technique, called aeration by the-stratification, consists of the creation of one or several local air curtains, which generate an air life effect, leading water to circulate from bottom to surface and vice-versa. This process is calculated in order to prevent thermal stratification during the warm seasons. Contacting the air at the surface of the pond oxygenates water, the oxygen levels remaining constant throughout the entire water column. (Author)

  3. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  4. 33 CFR 334.1280 - Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. 334.1280 Section 334.1280 Navigation and Navigable... REGULATIONS § 334.1280 Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. (a...

  5. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  6. Performance evaluation of mobile downflow booths for reducing airborne particles in the workplace.

    Science.gov (United States)

    Lo, Li-Ming; Hocker, Braden; Steltz, Austin E; Kremer, John; Feng, H Amy

    2017-11-01

    Compared to other common control measures, the downflow booth is a costly engineering control used to contain airborne dust or particles. The downflow booth provides unidirectional filtered airflow from the ceiling, entraining released particles away from the workers' breathing zone, and delivers contained airflow to a lower level exhaust for removing particulates by filtering media. In this study, we designed and built a mobile downflow booth that is capable of quick assembly and easy size change to provide greater flexibility and particle control for various manufacturing processes or tasks. An experimental study was conducted to thoroughly evaluate the control performance of downflow booths used for removing airborne particles generated by the transfer of powdered lactose between two containers. Statistical analysis compared particle reduction ratios obtained from various test conditions including booth size (short, regular, or extended), supply air velocity (0.41 and 0.51 m/s or 80 and 100 feet per minute, fpm), powder transfer location (near or far from the booth exhaust), and inclusion or exclusion of curtains at the booth entrance. Our study results show that only short-depth downflow booths failed to protect the worker performing powder transfer far from the booth exhausts. Statistical analysis shows that better control performance can be obtained with supply air velocity of 0.51 m/s (100 fpm) than with 0.41 m/s (80 fpm) and that use of curtains for downflow booths did not improve their control performance.

  7. Experimental data and boundary conditions for a Double - Skin Facade building in transparent insulation mode

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Heiselberg, Per; Jensen, Rasmus Lund

    was carried out in a full scale test facility ‘The Cube’, in order to compile three sets of high quality experimental data for validation purposes. The data sets are available for preheating mode, external air curtain mode and transparent insulation mode. The objective of this article is to provide the reader...... with all information about the experimental data and measurements, necessary to complete an independent empirical validation of any simulation tool. The article includes detailed information about the experimental apparatus, experimental principles and experimental full-scale test facility ‘The Cube...

  8. Thermal and flow analysis of the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% effort of Title 1)

    International Nuclear Information System (INIS)

    Steinke, R.G.; Mueller, C.; Knight, T.D.

    1998-03-01

    The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions

  9. Catalog of Audiovisual Productions. Volume 4. DoD Productions Cleared for Public Release

    Science.gov (United States)

    1984-06-01

    PRINCIPLES OF (25712 IO) NUTRITION.THE FIRST YEARS OPERATION NO DECK TO STRUT UPON (30403 DA) (29859 DA) (25585 IR) NUWAX- B1 DOCUMENTARY • NUCLEAR...CHAMPIONSHIP. RACE TRACA; ARMY. NAVY AND AIR FORCE ENTATHLON ’ ’ ’ I R ISH UPSET I N LAST GAME’’ FOOTBALL TEAMS SHAPE UP FOR THE 19’ B1 ’IRON CURTAIN...STADIVM IN WASHINGTON. REPNRLICANS 49311-DA I&E SPORTIREEL CIIA*G FOR PE 11. WINl I TO 1. RUGBY IS PLAYED IN FLORENICE, 161K MOTION PICTURE, 020 NIH, 1957

  10. AirPEx. Air Pollution Exposure Model

    Energy Technology Data Exchange (ETDEWEB)

    Freijer, J.I.; Bloemen, H.J.Th.; De Loos, S.; Marra, M.; Rombout, P.J.A.; Steentjes, G.M.; Van Veen, M.P.

    1997-12-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The principal grounds for studying the inhalatory exposure of humans to air pollutants are formed by the need for realistic exposure/dose estimates to evaluate the health effects of these pollutants. The AirPEx (Air Pollution Exposure) model, developed to assess the time- and space-dependence of inhalatory exposure of humans to air pollution, has been implemented for use as a Windows 3.1 computer program. The program is suited to estimating various exposure and dose quantities for individuals, as well as for populations and subpopulations. This report describes the fundamentals of the AirPEx model and provides a user manual for the computer program. Several examples included in the report illustrate the possibilities of the AirPEx model in exposure assessment. The model will be used at the National Institute of Public Health and the Environment as a tool in analysing the current exposure of the Dutch population to air pollutants. 57 refs.

  11. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative...... and the humidity of the room air. At a low humidity level of 30% an increased velocity could compensate for the decrease in perceived air quality due to an elevated temperature ranging from 20 °C to 26 °C. In a room with 26 °C, increased air movement was also able to compensate for an increase in humidity from 30...... humidity (30, 40 and 70%) and pollution level (low and high). Most of the experiments were performed with and without facially applied airflow at elevated velocity. The importance of the use of recirculated room air and clean, cool and dry outdoor air was studied. The exposures ranged from 60. min to 235...

  12. Edificio para Cristalería Española

    Directory of Open Access Journals (Sweden)

    de la Joya, R.

    1964-03-01

    Full Text Available In the course of a series of lectures on the subject of curtain walls, held at the Higher Technical College of Architecture, in Madrid, the author described his own experience whilst constructing a building (designed by him and by Mr. Manuel Barbero for the firm Cristalería Española, at San Andrés del Palomar, Barcelona. Mr. De la Joya summarised the advantages that foreign experts attribute to curtain walls. These advantages are: less weight of the materials of the enclosing walls; maximum use of the available building surface; cheaper foundations; better building time control; superior quality and accuracy; and greater maintenance facility. The lecturer then explained why, and in what aspects, he was in disagreement with the above supposed advantages. He dealt with these as follows: 1. In terms of present day construction, with concrete blocks and lightweight flooring structures, it is not easy to save much weight, owing to the number of special fittings that are necessary to support and keep the curtain wall in place.—2. Although in theory a. curtain wall may be only 4 or 5 cm thick, the truth is that unless heating or air conditioning is provided on a much larger scale, a special internal protection layer is necessary.—3. It is difficult to reduce the cost of the foundations by fitting curtain walls, and any calculated saving in cost in this aspect is more theoretical than real.—4. Building time estimates usually fail to work out in practice, and in addition to this, workmanship quality is not yet very satisfactory.—5. Curtain walls require periodic overhauls, so that they do not age too rapidly, and in this sense they are no better than traditional walls. The lecturer also made a number of additional points, one of them being that he did not advise the use of curtain walls in Spain (because of the cheapness of brickwalls, the climate, the high cost of air conditioning, etc. He also emphasized how important it is to make a very

  13. A mixed air/air and air/water heat pump system ensures the air-conditioning of a cinema; Un systeme mixte PAC air/air et air/eau climatise un cinema

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-03-01

    This article presents the air conditioning system of a new cinema complex of Boulogne (92, France) which comprises a double-flux air processing plant and two heat pumps. Each heat pump has two independent refrigerating loops: one with a air condenser and the other with a water condenser. This system allows to limit the power of the loop and to reduce the size of the cooling tower and of the vertical ducts. This article describes the technical characteristics of the installation: thermodynamic units, smoke clearing, temperature control, air renewing. (J.S.)

  14. Kajian Analitik Perencanaan Pintu Air Pembangkit Listrik Tenaga Air

    OpenAIRE

    Pradoto, Pradoto

    1993-01-01

    Pada pintu air pembangkit listrik tenaga air umumnya dipasang pengauat-penguat (girder). Tujuannya agar pintu air kuat dalam menahan tekanan air. Tekanan air yang diderita oleh pintu air cukup besar karena dipasang pada kedalaman + 50 meter di bawah permukaan air. Permasalahan yang timbul adalah menentukan posisi atau letak girder pada pintu air.

  15. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  16. Air ejector augmented compressed air energy storage system

    Science.gov (United States)

    Ahrens, F.W.; Kartsounes, G.T.

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  17. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  18. Air Consumption Analysis of Air-Jet Weaving

    Directory of Open Access Journals (Sweden)

    RAJ KUMAR KHIANI

    2016-07-01

    Full Text Available In Textile industry, production is mostly key concern for Industry owner. This always has attracted researchers and machines manufacturers to make new developments in process and machines. Air-jet is one of the leading and successful highest productive weaving machines. However, it is now well established that due to add of charges of compressed air, manufacturing cost of air-jet weaving machine is higher as compared with rapier and projectile weaving machines. This is why countries having energy issues do not prefer air-jet weaving machines comparing projectile weaving machines. In this regard, several researchers and machine manufacturers have continuously been working to improve the efficiency of air-jet weft insertion. However, industry practice is as important as design made by researchers. The aim of this research is to investigate the air consumption of air-jet weaving on industrial scale practice. In this study, five weaving machine of same manufacturer and model were selected. It was observed that despite of manufacturing same quality of fabric, air consumption was varying almost in all weaving machines. Conventionally, mill workers adopt hit and trial practice in weaving industry including airpressure setting which leads to variation of nozzle pressure. Main reason of disparity of air consumption in air-jet weaving machines may be variation of distance from compressor to weaving machines, number of joints, un-necessary valve opening and pipes leakages cause an increase of compressed air consumption.

  19. Andreas Acrivos Dissertation Award: Onset of Dynamic Wetting Failure - The Mechanics of High-Speed Fluid Displacement

    Science.gov (United States)

    Vandre, Eric

    2014-11-01

    water/glycerol solutions. In addition, liquid pressurization (relative to ambient air) further postpones air entrainment when the meniscus is located near a sharp corner along the plate. Recorded critical speeds compare well to predictions from the model, supporting the hydrodynamic mechanism for the onset of wetting failure. Lastly, the industrial practice of curtain coating is investigated using the hydrodynamic model. Due to the complexity of this system, a new computational approach is developed combining a finite element method and lubrication theory in order to improve the efficiency of the numerical analysis. Results show that the onset of wetting failure varies strongly with the operating conditions of this system. In addition, stresses from the air flow dramatically affect the steady wetting behavior of curtain coating. Ultimately, these findings emphasize the important role of two-fluid displacement mechanics in high-speed wetting systems.

  20. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  1. AirPEx: Air Pollution Exposure Model

    NARCIS (Netherlands)

    Freijer JI; Bloemen HJTh; Loos S de; Marra M; Rombout PJA; Steentjes GM; Veen MP van; LBO

    1997-01-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The

  2. Numerical and Analytical Model of an Electrodynamic Dust Shield for Solar Panels on Mars

    Science.gov (United States)

    Calle, C. I.; Linell, B.; Chen, A.; Meyer, J.; Clements, S.; Mazumder, M. K.

    2006-01-01

    Masuda and collaborators at the University of Tokyo developed a method to confine and transport particles called the electric curtain in which a series of parallel electrodes connected to an AC source generates a traveling wave that acts as a contactless conveyor. The curtain electrodes can be excited by a single-phase or a multi-phase AC voltage. A multi-phase curtain produces a non-uniform traveling wave that provides controlled transport of those particles [1-6]. Multi-phase electric curtains from two to six phases have been developed and studied by several research groups [7-9]. We have developed an Electrodynamic Dust Shield prototype using threephase AC voltage electrodes to remove dust from surfaces. The purpose of the modeling work presented here is to research and to better understand the physics governing the electrodynamic shield, as well as to advance and to support the experimental dust shield research.

  3. Verification of radiation exposure using lead shields

    International Nuclear Information System (INIS)

    Hayashida, Keiichi; Yamamoto, Kenyu; Azuma, Masami

    2016-01-01

    A long time use of radiation during IVR (intervention radiology) treatment leads up to an increased exposure on IVR operator. In order to prepare good environment for the operator to work without worry about exposure, the authors examined exposure reduction with the shields attached to the angiography instrument, i. e. lead curtain and lead glass. In this study, the lumber spine phantom was radiated using the instrument and the radiation leaked outside with and without shields was measured by the ionization chamber type survey meter. The meter was placed at the position which was considered to be that for IVR operator, and changed vertically 20-100 cm above X-ray focus by 10 cm interval. The radiation at the position of 80 cm above X-ray focus was maximum without shield and was hardly reduced with lead curtain. However, it was reduced with lead curtain plus lead glass. Similar reduction effects were observed at the position of 90-100 cm above X-ray focus. On the other hand, the radiation at the position of 70 cm above X-ray focus was not reduced with either shield, because that position corresponded to the gap between lead curtain and lead glass. The radiation at the position of 20-60 cm above X-ray focus was reduced with lead curtain, even if without lead glass. These results show that lead curtain and lead glass attached to the instrument can reduce the radiation exposure on IVR operator. Using these shields is considered to be one of good means for IVR operator to work safely. (author)

  4. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  5. Compare the difference of architecture design in Hong Kong and Penang – Exterior wall

    Directory of Open Access Journals (Sweden)

    Liu Wen Tao

    2015-12-01

    Full Text Available This research focuses on the exterior wall of architecture design of Hong Kong and Penang, it also analyzes how light pollution affects human life. As we know, Hong Kong prefers to use steel to build skyscrapers and middle or high rise buildings. However, Penang prefers to use concrete to do the construction. So, there are some advantages and disadvantages between the glass curtain wall and concrete wall in Hong Kong and Penang. The researcher used 400 samples to determine effect of the glass curtain wall and concrete wall on human life in Hong Kong and Penang separately. The result is light pollution created by glass curtain wall in Hong Kong is a serious problem to residents’ life. The glass curtain wall seriously glaze people’s eyes who drive or walk on the street. Thus, many car accidents were caused by this problem. The concrete wall is more often contaminated by fungus and difficult to clean. But, concrete wall is more natural and green for humans. Therefore, from the sustainable aspect that concrete is more healthy for humans, the previous researchers suggest that if the exterior wall is a mixture of both glass curtain and concrete it will not cause light pollution and will be easily involved in the natural environment.

  6. Air-cooled, hydrogen-air fuel cell

    Science.gov (United States)

    Shelekhin, Alexander B. (Inventor); Bushnell, Calvin L. (Inventor); Pien, Michael S. (Inventor)

    1999-01-01

    An air-cooled, hydrogen-air solid polymer electrolyte (SPE) fuel cell with a membrane electrode assembly operatively associated with a fluid flow plate having at least one plate cooling channel extending through the plate and at least one air distribution hole extending from a surface of the cathode flow field into the plate cooling channel.

  7. Curtain-Lifting Winds Allow Rare Glimpse into Massive Star Factory

    Science.gov (United States)

    2003-06-01

    the earliest ones (astronomers here refer to "protostars"), high-mass stars evolve much faster than low-mass stars. It is therefore more difficult to "catch" massive stars in the critical phases of early formation. And, what is even worse, due to this rapid development, young high-mass protostars are usually very deeply embedded in their natal clouds and therefore not detectable at optical wavelengths during the (short) phase before nuclear reactions start in their interior. There is simply not enough time for the cloud to disperse - when the curtain finally lifts, allowing a view of the new star, it is already past those earliest stages. Is there a way around these problems? "Yes", says Dieter Nürnberger of ESO-Santiago, "you just have to look in the right place and remember Bob Dylan...!". This is what he did. "The answer, my friend, is blowing by the wind..." Imagine that it would be possible to blow away most of the obscuring gas and dust around those high-mass protostars! Even the strongest desire of the astronomers cannot do it, but there are fortunately others who are better at it! Some high-mass stars form in the neighbourhood of clusters of hot stars, i.e., next to their elder brethren. Such already evolved hot stars are a rich source of energetic photons and produce powerful stellar winds of elementary particles (like the "solar wind" but many times stronger) which impact on the surrounding interstellar gas and dust clouds. This process may lead to partial evaporation and dispersion of those clouds, thereby "lifting the curtain" and letting us look directly at young stars in that region, also comparatively massive ones at a relatively early evolutionary stage. The NGC 3603 region ESO PR Photo 16a/03 ESO PR Photo 16a/03 [Preview - JPEG: 400 x 469 pix - 70k [Normal - JPEG: 800 x 938 pix - 544k] Caption: PR Photo 16a/03 shows the sky region around NGC 3603, a cluster of young, hot stars (of the "OB-type") still partly embedded in its natal cloud of gas and

  8. An experimental evaluation on air purification performance of Clean-Air Heat Pump (CAHP) air cleaner

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Sun, Yuexia

    2018-01-01

    was 96.8%, which indicated that the most of gaseous pollutants were not accumulated in the CAHP. The regeneration temperature for the wheel could affect the air purification performance of CAHP. At 70 °C of regeneration temperature, the air-cleaning efficiency reached 96.7%. Up to 70% of the outdoor air......The escalation of energy consumption in buildings and heightened concerns about acceptable indoor air quality stimulate interest in the usage of air cleaner as an adjunct for indoor environmental conditioning. A regenerative desiccant wheel integrated into a ventilation system termed Clean-Air Heat...... Pump (CAHP) can improve the air quality during the process of dehumidification without using additional energy. An experimental study in a field lab was performed to investigate the air cleaning performance of CAHP. Photoacoustic gas analyzer-INNOVA was used to characterize chemical removal of indoor...

  9. AirData

    Data.gov (United States)

    U.S. Environmental Protection Agency — The AirData site provides access to yearly summaries of United States air pollution data, taken from EPA's air pollution databases. AirData has information about...

  10. Can a Clean-Air Heat Pump (CAHP) maintain air purification capability when using polluted air for regeneration?

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei

    2018-01-01

    Clean Air Heat Pump (CAHP) was one type of rotary desiccant cooling system which combined a silica gel rotor with a heat pump to achieve air cleaning, dehumidifying and cooling in buildings. Using exhaust air from the conditioned room for regeneration of the silica gel rotor might have an advantage...... on reducing the regeneration air temperature and further improving the energy performance of the CAHP. However, the exhaust air carried a lot of indoor air pollutants. Whether using exhaust air for the regeneration of the silica gel rotor had an impact on the air cleaning performance of the CAHP...... was experimentally studied. The results showed that using the air contained acetone or toluene for regeneration reduced the pollutants removal capability of CAHP with a reduction of approx. 10% in air cleaning efficiency. The energy performance of the CAHP when using exhaust air for regeneration was also evaluated...

  11. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, it's ...

  12. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  13. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  14. Air Ambient-Operated pNIPAM-Based Flexible Actuators Stimulated by Human Body Temperature and Sunlight.

    Science.gov (United States)

    Yamamoto, Yuki; Kanao, Kenichiro; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu

    2015-05-27

    Harnessing a natural power source such as the human body temperature or sunlight should realize ultimate low-power devices. In particular, macroscale and flexible actuators that do not require an artificial power source have tremendous potential. Here we propose and demonstrate electrically powerless polymer-based actuators operated at ambient conditions using a packaging technique in which the stimulating power source is produced by heat from the human body or sunlight. The actuating angle, force, and reliability are discussed as functions of temperature and exposure to sunlight. Furthermore, a wearable device platform and a smart curtain actuated by the temperature of human skin and sunlight, respectively, are demonstrated as the first proof-of-concepts. These nature-powered actuators should realize a new class of ultimate low-power devices.

  15. 75 FR 71596 - Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2010-11-24

    ... rulemaking because the provision within EISA which stipulates that off mode and standby mode energy usage... than night curtains made of plastic, linoleum, or other non- reflective materials. In addition, each... proposes a 6-hour test period to approximate the typical usage of a night curtain. In studies analyzing the...

  16. Contamination of environmental surfaces by methicillin-resistant Staphylococcus aureus (MRSA) in rooms of inpatients with MRSA-positive body sites.

    Science.gov (United States)

    Kurashige, E Jessica Ohashi; Oie, Shigeharu; Furukawa, H

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary. Copyright © 2016. Published by Elsevier Editora Ltda.

  17. Experiments by the Mexican NNEC on the Control of Airborne Radioactive Contamination; Experiencias Realizadas en la CNEN de Mexico Sobre El Control de Contaminaciones Radiactivas Arrastradas por el Aire

    Energy Technology Data Exchange (ETDEWEB)

    Bravo S, E. [Comision Nacional de Energia Nuclear, Mexico D.F. (Mexico)

    1968-12-15

    The installations of the Mexican National Nuclear Energy Commission have to deal with the problem of environmental contamination caused by dust and aerosols suspended in the air and originating mainly with such uranium-bearing ores as tyuyamunite, carnotite, betafite, technical-grade sodium uranate, ammonium uranate concentrate, uranium tetrafluoride and uranium dioxide. To prevent environmental contamination by these radioactive materials, the Commission has experimented with three different systems, based on the principle of extracting the dust from the environment, passing it through a cyclone system, separating the particles of larger size and controlling the small particles or aerosols by means of filtration, dilution in liquid columns and dilution in liquid curtains. On the basis of the results obtained, plans have been made for supplementing the systems with an adsorption column and an ion exchange column, depending on the specific requirements of each laboratory. (author) [Spanish] En las instalaciones de la Comision Nacional de Energia Nuclear de Mexico existe el problema de la contaminacion ambiental producida por polvos y aerosoles suspendidos en el aire, de minerales uraniferos tales como tyuyamunita, carnotita, betafita, uranato de sodio tecnico, concentrado de uranato de amonio, tetrafluoruro de uranio y bioxido de uranio fundamentalmente. Para evitar dicha contaminacion del medio ambiente con los materiales radiactivos mencionados, se han experimentado tres diferentes sistemas cuyo principio consiste en la extraccion de los polvos del medio ambiente, pasandolos a un sistema de ciclon, separando las particulas de mayor tamano y controlando las particulas pequenas o aerosoles por medio de filtracion, dilucion en columnas liquidas y dilucion en cortinas liquidas. Sobre la base de los resultados obtenidos se ha proyectado completar los sistemas de acuerdo a las necesidades especificas de cada laboratorio con una columna de adsorcion y otra de intercambio

  18. 30 CFR 75.1730 - Compressed air; general; compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air; general; compressed air systems... Compressed air; general; compressed air systems. (a) All pressure vessels shall be constructed, installed... Safety and Health district office. (b) Compressors and compressed-air receivers shall be equipped with...

  19. Metal-air batteries with high energy density: Li-air versus Zn-air

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang-Soo; Sun, Tai Kim; Cao, Ruiguo; Choi, Nam-Soon; Lee, Kyu Tae; Cho, Jaephil [Interdisciplinary School of Green Energy, Ulsan National Institute of Science and Technology (UNIST), Ulsan (Korea, Republic of); Liu, Meilin [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA (United States)

    2011-01-01

    In the past decade, there have been exciting developments in the field of lithium ion batteries as energy storage devices, resulting in the application of lithium ion batteries in areas ranging from small portable electric devices to large power systems such as hybrid electric vehicles. However, the maximum energy density of current lithium ion batteries having topatactic chemistry is not sufficient to meet the demands of new markets in such areas as electric vehicles. Therefore, new electrochemical systems with higher energy densities are being sought, and metal-air batteries with conversion chemistry are considered a promising candidate. More recently, promising electrochemical performance has driven much research interest in Li-air and Zn-air batteries. This review provides an overview of the fundamentals and recent progress in the area of Li-air and Zn-air batteries, with the aim of providing a better understanding of the new electrochemical systems. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Nitrogen fluorescence in air for observing extensive air showers

    CERN Document Server

    Keilhauer, B; Fraga, M; Matthews, J; Sakaki, N; Tameda, Y; Tsunesada, Y; Ulrich, A

    2012-01-01

    Extensive air showers initiate the fluorescence emissions from nitrogen molecules in air. The UV-light is emitted isotropically and can be used for observing the longitudinal development of extensive air showers in the atmosphere over tenth of kilometers. This measurement technique is well-established since it is exploited for many decades by several cosmic ray experiments. However, a fundamental aspect of the air shower analyses is the description of the fluorescence emission in dependence on varying atmospheric conditions. Different fluorescence yields affect directly the energy scaling of air shower reconstruction. In order to explore the various details of the nitrogen fluorescence emission in air, a few experimental groups have been performing dedicated measurements over the last decade. Most of the measurements are now finished. These experimental groups have been discussing their techniques and results in a series of \\emph{Air Fluorescence Workshops} commenced in 2002. At the 8$^{\\rm{th}}$ Air Fluoresc...

  1. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  2. AIRS-only Product on Giovanni for Exploring Up-to-date AIRS Observation and Comparing with AIRS+AMSU Product

    Science.gov (United States)

    Ding, F.; Hearty, T. J., III; Theobald, M.; Vollmer, B.; Wei, J.

    2017-12-01

    The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002 for the global observations of the atmospheric state. Giovanni, a web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important variables, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases, from version 6 AIRS product are available on Giovanni. The AIRS is an instrument suite comprised of a hyperspectral infrared instrument AIRS and two multichannel microwave instruments, the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB). As the HSB ceased operation in very early stage of AIRS mission, the AIRS project operates two parallel retrieval algorithms: one using both IR and MW measurements (AIRS+AMSU) and the other using only IR measurements (AIRS-only) for the most time of the mission. The AIRS+AMSU product is better and the variables on Giovanni are from it. However, the generation of AIRS+AMSU product has been suspended since the AMSU instrument anomaly occurred in late 2016. To continue exploring up-to-date AIRS observations, the same set of variables from the AIRS-only product are added on Giovanni by the GES DSIC. This will also support the comparison of AIRS-only with AIRS+AMSU retrievals. In the presentation, we will demonstrate the visualization of AIRS-only product and the plots/statistics of comparison with AIRS+AMSU product using Giovanni.

  3. A new air quality monitoring and early warning system: Air quality assessment and air pollutant concentration prediction.

    Science.gov (United States)

    Yang, Zhongshan; Wang, Jian

    2017-10-01

    Air pollution in many countries is worsening with industrialization and urbanization, resulting in climate change and affecting people's health, thus, making the work of policymakers more difficult. It is therefore both urgent and necessary to establish amore scientific air quality monitoring and early warning system to evaluate the degree of air pollution objectively, and predict pollutant concentrations accurately. However, the integration of air quality assessment and air pollutant concentration prediction to establish an air quality system is not common. In this paper, we propose a new air quality monitoring and early warning system, including an assessment module and forecasting module. In the air quality assessment module, fuzzy comprehensive evaluation is used to determine the main pollutants and evaluate the degree of air pollution more scientifically. In the air pollutant concentration prediction module, a novel hybridization model combining complementary ensemble empirical mode decomposition, a modified cuckoo search and differential evolution algorithm, and an Elman neural network, is proposed to improve the forecasting accuracy of six main air pollutant concentrations. To verify the effectiveness of this system, pollutant data for two cities in China are used. The result of the fuzzy comprehensive evaluation shows that the major air pollutants in Xi'an and Jinan are PM 10 and PM 2.5 respectively, and that the air quality of Xi'an is better than that of Jinan. The forecasting results indicate that the proposed hybrid model is remarkably superior to all benchmark models on account of its higher prediction accuracy and stability. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

    International Nuclear Information System (INIS)

    Guo, H.; Lee, S.C.; Chan, L.Y.

    2004-01-01

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM 10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ) and sulfur dioxide (SO 2 ). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM 10 , TBC, CO and NO 2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM 10 and TBC. The elevated PM 10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM 10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m 3 , and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m 3 , which was above the HKIAQO standard of 1000 CFU/m 3 . The bacteria levels at other three stalls were all below the HKIAQO standard

  5. MEPR versus EEPR valves in open supermarket refrigerated display cabinets

    International Nuclear Information System (INIS)

    Tahir, A.; Bansal, P.K.

    2005-01-01

    This paper presents the comparative experimental field performance of mechanical evaporator pressure regulating valves (MEPR) and electronic evaporator pressure regulating valves (EEPR) under the identical operating conditions of supermarket open multi-deck refrigerated display cabinets. The main goal of the supermarket refrigeration system design is to keep the displayed product at the required constant temperature, while minimising the cooling load to increase the overall energy efficiency of the system. Field tests have shown that the electronic evaporator pressure valve has a significant effect on improving the cabinet temperature and reducing the rate of frost formation on the evaporator coils with subsequent improvements in the air curtain strength

  6. Pure Air`s Bailly scrubber: A four-year retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Manavi, G.B.; Vymazal, D.C. [Pure Air, Allentown, PA (United States); Sarkus, T.A. [Dept. of Energy, Pittsburgh, PA (United States)

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project has completed four highly successful years of operation at NIPSCO`s Bailly Station. As part of their program, Pure Air has concluded a six-part study of system performance. This paper summarizes the results of the demonstration program, including AFGD performance on coals ranging from 2.0--2.4% sulfur. The paper highlights novel aspects of the Bailly facility, including pulverized limestone injection, air rotary sparger for oxidation, wastewater evaporation system and the production of PowerChip{reg_sign} gypsum. Operations and maintenance which have led to the facility`s notable 99.47% availability record are also discussed. A project company, Pure Air on the Lake Limited Partnership, owns the AFGD facility. Pure Air was the turn key contractor and Air Products and Chemicals, Inc. is the operator of the AFGD system.

  7. Heat Recovery Ventilation for Housing: Air-to-Air Heat Exchangers.

    Science.gov (United States)

    Corbett, Robert J.; Miller, Barbara

    The air-to-air heat exchanger (a fan powered ventilation device that recovers heat from stale outgoing air) is explained in this six-part publication. Topic areas addressed are: (1) the nature of air-to-air heat exchangers and how they work; (2) choosing and sizing the system; (3) installation, control, and maintenance of the system; (4) heat…

  8. Strength of smoke-free air laws and indoor air quality.

    Science.gov (United States)

    Lee, Kiyoung; Hahn, Ellen J; Robertson, Heather E; Lee, Seongjik; Vogel, Suzann L; Travers, Mark J

    2009-04-01

    Smoke-free air laws have been implemented in many Kentucky communities to protect the public from the harmful effects of secondhand smoke exposure. The impact of different strengths of smoke-free air laws on indoor air quality was assessed. Indoor air quality in hospitality venues was assessed in seven communities before and after comprehensive smoke-free air laws and in two communities only after partial smoke-free air laws. One community was measured three times: before any smoke-free air law, after the initial partial law, and after the law was strengthened to cover all workplaces and public places with few exemptions. Real-time measurements of particulate matters with 2.5 mum aerodynamic diameter or smaller (PM(2.5)) were obtained. When comprehensive smoke-free air laws were implemented, indoor PM(2.5) concentrations decreased significantly from 161 to 20 microg/m3. In one community that implemented a comprehensive smoke-free law after initially passing a partial law, indoor PM(2.5) concentrations were 304 microg/m3 before the law, 338 microg/m3 after the partial law, and 9 microg/m3 after the comprehensive law. The study clearly demonstrated that partial smoke-free air laws do not improve indoor air quality. A significant linear trend indicated that PM(2.5) levels in the establishments decreased with fewer numbers of burning cigarettes. Only comprehensive smoke-free air laws are effective in reducing indoor air pollution from secondhand tobacco smoke.

  9. Air Abrasion

    Science.gov (United States)

    ... Chapters What Is Air Abrasion? What Happens? The Pros and Cons Will I Feel Anything? Is Air ... will perform any procedures that use air-abrasion technology. Ask your dentist if he or she uses ...

  10. The urban air; L'air de la ville

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This paper presents the abstracts of conferences proposed during the meeting on the urban air, organized by the French Meteorological Society in november 2002. These conferences dealt with the air quality monitoring, the public health impacts, the air pollution in function of the meteorological effects, the pollutants, the main factors of the air quality and the models of the meteorology. (A.L.B.)

  11. Released air during vapor and air cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz [VŠB-Technical University of Ostrava, Faculty of Mechanical Engineering, Department of Hydromechanics and Hydraulic Equipment, 17. listopadu 15, 708 33 Ostrava-Poruba (Czech Republic)

    2016-06-30

    Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

  12. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  13. Air pollution and the school air environment

    OpenAIRE

    Fsadni, Peter; Montefort, Stephen

    2015-01-01

    There is growing concern about the association of school indoor air quality (SIAQ) with asthma, rhinitis, and rhinoconjunctivitis. Students and school staff deserve the highest standards of school air quality to ensure a safe and productive environment for our children’s education. Existing studies highlight the presence of several air pollutants present within school classrooms that have a direct association with poor health and poor student performance. Very little data exist ab...

  14. Advances in Understanding Air Pollution and Cardiovascular Diseases: The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air)

    Science.gov (United States)

    Kaufman, Joel D.; Spalt, Elizabeth W.; Curl, Cynthia L.; Hajat, Anjum; Jones, Miranda R.; Kim, Sun-Young; Vedal, Sverre; Szpiro, Adam A.; Gassett, Amanda; Sheppard, Lianne; Daviglus, Martha L.; Adar, Sara D.

    2016-01-01

    The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air) leveraged the platform of the MESA cohort into a prospective longitudinal study of relationships between air pollution and cardiovascular health. MESA Air researchers developed fine-scale, state-of-the-art air pollution exposure models for the MESA Air communities, creating individual exposure estimates for each participant. These models combine cohort-specific exposure monitoring, existing monitoring systems, and an extensive database of geographic and meteorological information. Together with extensive phenotyping in MESA—and adding participants and health measurements to the cohort—MESA Air investigated environmental exposures on a wide range of outcomes. Advances by the MESA Air team included not only a new approach to exposure modeling but also biostatistical advances in addressing exposure measurement error and temporal confounding. The MESA Air study advanced our understanding of the impact of air pollutants on cardiovascular disease and provided a research platform for advances in environmental epidemiology. PMID:27741981

  15. Edificio Ince - Caracas (Venezuela

    Directory of Open Access Journals (Sweden)

    Sanabria, Tomás José

    1971-08-01

    Full Text Available This project includes a tall building, headquarters of the owning organisation, a four storey block, used for professional training purposes, and an auditorium. In addition there is underground space used as car park, and a small plaza with gardens, meant as an open air exhibition space for sculptures. The structure of the buildings is reinforced concrete, and the curtain walls are of anodizod aluminium.El conjunto comprende: el edificio torre, sede de la Institución; un bloque de cuatro plantas, destinado para centro de formación profesional, y un auditorio. Hay, además, un sótano, que alberga: el estacionamiento de vehículos y zonas de instalaciones diversas, y una plaza tratada paisajísticamente y destinada a exposición permanente de escultura al aire libre. Su estructura es de hormigón armado y los cerramientos son de aluminio anodizado.

  16. Field testing of behavioral barriers for cooling water intake structures -test site 1 - Pickering Nuclear Generating Station

    International Nuclear Information System (INIS)

    Patrick, P.H.; McKinley, R.S.; Micheletti, W.C.

    1988-01-01

    A multi-year research program was developed by the Electric Power Research Institute to evaluate the effectiveness of selected behavioral systems for fish exclusion at sites representative of different aquatic environments. The first test site was the Pickering Nuclear Generating Station (NGS) located on Lake Ontario which represented the Great Lakes environment. A single pneumatic popper, a low frequency, high amplitude sound deterrent, was found to effectively exclude adult alewife, the principal species impinged at Pickering NGS. An air bubble curtain, used either alone or combined with strobe lights, was not a consistent deterrent. Effectiveness of air bubbles was only enhanced when used in association with a popper. Strobe lights were the least effective of the three devices tested. Operation of all three devices together did not surpass the effectiveness of the popper when used alone. Sound deterrents show promise for fish exclusion at generating stations located on the Great Lakes

  17. Air Baltic: Estonian Air on nurka surutud / Teele Tammeorg

    Index Scriptorium Estoniae

    Tammeorg, Teele

    2010-01-01

    Air Balticu asepresidendi Janis Vanagsi hinnangul on Estonian Air aastaid jätnud tähelepanuta oma peamised turismiturud ning on praegu halvas seisus. Air Baltic on endiselt huvitatud Estonian Airi ostust. Majandus- ja kommunikatsiooniminister Juhan Partsi seisukoht

  18. Reshocks, rarefactions, and the generalized Layzer model for hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Mikaelian, K.O.

    2008-01-01

    We report numerical simulations and analytic modeling of shock tube experiments on Rayleigh-Taylor and Richtmyer-Meshkov instabilities. We examine single interfaces of the type A/B where the incident shock is initiated in A and the transmitted shock proceeds into B. Examples are He/air and air/He. In addition, we study finite-thickness or double-interface A/B/A configurations like air/SF 6 /air gas-curtain experiments. We first consider conventional shock tubes that have a 'fixed' boundary: A solid endwall which reflects the transmitted shock and reshocks the interface(s). Then we focus on new experiments with a 'free' boundary--a membrane disrupted mechanically or by the transmitted shock, sending back a rarefaction towards the interface(s). Complex acceleration histories are achieved, relevant for Inertial Confinement Fusion implosions. We compare our simulation results with a generalized Layzer model for two fluids with time-dependent densities, and derive a new freeze-out condition whereby accelerating and compressive forces cancel each other out. Except for the recently reported failures of the Layzer model, the generalized Layzer model and hydrocode simulations for reshocks and rarefactions agree well with each other, and remain to be verified experimentally

  19. Numerical analysis for temperature profile of the closed house using computational fluid dynamics

    Science.gov (United States)

    Setiadi, Rizki; Munadi, Tauviqirrahman, Mohammad

    2018-03-01

    This study aims to analyze the air temperature distribution in the closed house system for broiler using ABAQUS CFD Model. The obtained data is used for placing the temperature sensor before making the control system for the closed house. The dimesion of the experimental house was 30 m × 12 m × 2 m (length × width × height) which could be occupied by 7.500 broiler. The wall was made from expose mercy brick and curtain, ventilation system used 7 exhaust fan with diameter 1 m and 2 cooling unit, the roof was made from wood, and system used 45 of 7 watt lamp. The results of the analysis show that temperature distribution occurs on temperature 21-33.5°C and still relatively comfortable for broiler at the age of 1-21days. The air temperature distribution near the cooling unit is lower and increases to near the exhaust fan. In addition, the air temperature in the area near the roof is more high than others.

  20. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  1. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  2. Analysis of air safety in the European system of air traffic

    Directory of Open Access Journals (Sweden)

    О.Є. Луппо

    2008-04-01

    Full Text Available  Article describes air traffic safety provision requirements in the Air Traffic Management system of Europe. Consideration of air traffic variation which affecting the air traffic management operations have been reviewed.

  3. Impulse sales cooler. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Per Henrik (DTI, Taastrup (Denmark))

    2010-11-15

    In the past years, the use of impulse coolers has increased considerably and it is estimated that at least 30.000 are installed in shops in Denmark. In addition, there are many small barrel-shaped can coolers. Most impulse coolers are open, which results in a large consumption of energy, and the refrigeration systems are often quite inefficient. A typical impulse cooler uses app. 5 - 8 kWh/day corresponding to a consumption of energy in the magnitude of 60 GWh/year. For several years, the Danish company Vestfrost A/S has produced an impulse sales cooler in the high-efficiency end and the energy consumption of the cooler is measured to be 4.15 kWh/day. The POS72 cooler formed the baseline of this project. At the start-up meeting in 2008, several ideas were discussed with the objective to reduce energy consumption and to use natural refrigerants. Among the ideas were better air curtains, removable lids, better condensers, use of R600a refrigeration system and better insulation. Three generations of prototypes were built and tested in a climate chamber at Danish Technological Institute and the third generation showed very good performance: the energy consumption was measured to 2.215 kWh/day, which is a 47% reduction compared to the baseline. That was achieved by: 1) Improving the cold air cycling system including the air curtain. 2) Using the natural refrigerant R600a (isobutane) and the Danfoss NLE9KTK compressor, which has better efficiency compared to the compressor in the baseline product. 3) Using a box type condenser without fins (preventing dust build-up) and with a relatively high surface area. 4) Improving the insulation value of the plastic cabinet by reducing turbulence in the air gap between the plastic walls and improving the insulation value of the EPS moulded insulation surrounding the refrigeration system at the bottom of the cooler. 5) Preventing short-circuit of warm air around the condenser. 6) The improvements are cost efficient and will not add

  4. Advanced Architectures and Relatives of Air Electrodes in Zn–Air Batteries

    Science.gov (United States)

    Pan, Jing; Xu, Yang Yang; Yang, Huan; Dong, Zehua; Liu, Hongfang

    2018-01-01

    Abstract Zn–air batteries are becoming the promising power sources for portable and wearable electronic devices and hybrid/electric vehicles because of their high specific energy density and the low cost for next‐generation green and sustainable energy technologies. An air electrode integrated with an oxygen electrocatalyst is the most important component and inevitably determines the performance and cost of a Zn–air battery. This article presents exciting advances and challenges related to air electrodes and their relatives. After a brief introduction of the Zn–air battery, the architectures and oxygen electrocatalysts of air electrodes and relevant electrolytes are highlighted in primary and rechargeable types with different configurations, respectively. Moreover, the individual components and major issues of flexible Zn–air batteries are also highlighted, along with the strategies to enhance the battery performance. Finally, a perspective for design, preparation, and assembly of air electrodes is proposed for the future innovations of Zn–air batteries with high performance. PMID:29721418

  5. Hazardous Air Pollutants

    Science.gov (United States)

    ... Search Main menu Environmental Topics Air Bed Bugs Chemicals and Toxics Environmental Information by Location Greener Living Health Land, ... regulate toxic air pollutants, also known as air toxics, from categories of industrial facilities in two phases . About Hazardous Air Pollutants ...

  6. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  7. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  8. KERENTANAN KAWASAN TEPI AIR TERHADAP KENAIKAN PERMUKAAN AIR LAUT Kasus Kawasan Tepi Air Kota Surabaya

    Directory of Open Access Journals (Sweden)

    Iwan Suprijanto

    2003-01-01

    Full Text Available Even though global warming are still debates whether it will or not be happened, the changes on climate will influence activities of human. Regarding global warming issue, one of the impact that is very interesting to be investigated is sea level rise. Sea level rise is predicted has very big impact since, in general, in coastal areas locate a lot of important activities for such city or country. On the context of Indonesian locality, most of big cities such as Jakarta, Surabaya, Semarang, Makasar, etc. are located on the coastal area. Since a lot of important activities located on those cities, in general, sea level rise will influence the development processes of those cities. On the basis of the observation gathering in Surabaya City, the impact of sea level rise will influence not only the development of coastal area but also development of Surabaya City in general. The influence is because the area accommodates activities which are very important in city development both for present and future. The activities are port, industrial estate and location for new housing. Abstract in Bahasa Indonesia : Terlepas dari ketidakpastian mengenai terjadi atau tidaknya pemanasan global, setiap perubahan iklim di bumi akan memberikan dampak terhadap kelangsungan hidup manusia. Salah satu kajian yang saat ini banyak dilakukan berkaitan dengan isu pemanasan global adalah mengenai kenaikan permukaan air laut. Pengkajian mengenai kenaikan permukaan air laut tersebut penting mengingat dampak yang akan ditimbulkannya dan dengan kenyataan secara umum kawasan tepi air memegang peranan penting dalam perkembangan suatu kota ataupun negara. Hal ditandai dengan banyaknya aktivitas yang berlokasi di kawasan tepi air. Kondisi geografis Indonesia dengan duapertiga bagian wilayahnya adalah perairan, menjadikan Indonesia memiliki garis pantai terpanjang di dunia. Hal tersebut menjadikan pula beberapa bagian wilayah di Indonesia merupakan kawasan pesisir atau tepi air

  9. MICROBIOLOGICAL CHARACTERISTICS OF THE AIR BLOWN BY WARM AIR HAND DRYERS

    Directory of Open Access Journals (Sweden)

    Recai OÐUR; Omer Faruk TEKBAS; Osman HANCI; Umut OZCAN

    2005-02-01

    Full Text Available The aim of the study was to determine the microbiological characteristics of air blown from warm air hand dryers, and to compare findings with the microbiological characteristics of indoor air in which the dryer settled. Air samples was taken from different public places (shopping centers, restaurants and hospitals and investigated for total viable counts, coagulase negative Staphylococcus, E. Coli, Staphylococcus aureus and enteric pathogens. There were differences between sampling indoor places for some of the microorganisms, but all of the air samples taken from dryers contained more microorganisms than indoor air, and the differences between hand dryers and indoor air were statistically significant (p<0.05 except for enteric pathogens. As a result it could be said that warm air hand dryers could be microbiological contamination sources in restrooms or the other places that they are used. [TAF Prev Med Bull 2005; 4(1.000: 1-7

  10. Indoor air humidity, air quality, and health - An overview.

    Science.gov (United States)

    Wolkoff, Peder

    2018-04-01

    There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture

  11. Air conditioner

    International Nuclear Information System (INIS)

    Sato, Masaaki

    1993-01-01

    The present invention provides an air conditioner which can prevent an undesirable effects on a human body due to radon daughter nuclides in a closed space. That is, the concentration of the radon daughter nuclides in the air in the closed space is continuously measured. A necessary amount of ventilation air is determined based on the measured concentration to generate control signals. External air is introduced into the closed space by the generated control signals. With such procedures, necessary amount of external air is taken from the atmospheric air which can be regarded to have the radon daughter nuclide concentration substantially at zero, thereby enabling to reduce the concentration of the radon daughter nuclides in the closed space. As a result, undesired effects on the human body due to the radon daughter nuclides staying in the closed space can be prevented. According to simulation, the radon daughter nuclides are rapidly decreased only by ventilation only for three times or so in one hour. Accordingly, ventilation is extremely effective and convenient means as a countermeasure for the radon daughter nuclides. (I.S.)

  12. Ensuring clean air: Developing a clean air strategy for British Columbia

    International Nuclear Information System (INIS)

    1992-04-01

    In 1992, a clean air strategy will be developed to incorporate views of British Columbians on ways to meet goals related to air quality. A discussion paper is presented to provide information to those interested in participation in developing this strategy. The paper gives information on air quality issues important to the province, including local air quality, urban smog, ozone layer depletion, and global climate change. The views and concerns expressed by stakeholders who attended the Clean Air Conference in 1991 are summarized. The process used to develop the clean air strategy is outlined and some outcomes to be anticipated from the strategy are suggested, including policies and priorities for action to ensure clean air. Air pollutants of concern are total reduced sulfur, mainly from pulp mills and gas processing plants; smoke from wood burning; sulfur dioxide from pulp mills and gas plants; hydrogen fluoride from aluminum smelting; ground-level ozone in urban areas; and acid rain. Elements of a clean air strategy include a smoke management policy, management strategies for greenhouse gases and ozone smog, ozone layer protection measures, regional air quality management plans, and long-term planning efforts in energy use, transportation modes, community design, and land use. 12 refs., 14 figs., 2 tabs

  13. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  14. Air Land Sea Bulletin

    Science.gov (United States)

    2014-11-01

    Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based at Royal Air Force Honington, Suffolk (United...heavy as an actual weapon.4 Ideally, this practice imbued a soldier with more energy and stamina during real combat, given the feel of the genuine but...through tactical forces, to individual training. Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based

  15. The effect of air velocity on heat stress at increased air temperature

    DEFF Research Database (Denmark)

    Bjerg, B.; Wang, Xiaoshuai; Zhang, Guoqiang

    Increased air velocity is a frequently used method to reduce heat stress of farm animals housed in warm conditions. The main reason why the method works is that higher air velocity increases the convective heat release from the animals. Convective heat release from the animals is strongly related...... to the temperature difference between the surfaces of animals and the surrounding air, and this temperature difference declines when the air temperature approaches the animal body temperature. Consequently it can it by expected that the effect of air velocity decreases at increased air temperature. The literature...... on farm animals in warm conditions includes several thermal indices which incorporate the effect of air velocities. But, surprisingly none of them predicts a decreased influence of air velocity when the air temperature approaches the animal body temperature. This study reviewed published investigations...

  16. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  17. 14 CFR 399.86 - Payments for non-air transportation services for air cargo.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Payments for non-air transportation... Enforcement § 399.86 Payments for non-air transportation services for air cargo. The Board considers that... air carriers for non-air transportation preparation of air cargo shipments are for services ancillary...

  18. 21 CFR 211.46 - Ventilation, air filtration, air heating and cooling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Ventilation, air filtration, air heating and cooling. 211.46 Section 211.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Buildings and Facilities § 211.46 Ventilation, air filtration, air heating and cooling. (a) Adequate...

  19. Air conditioning systems to clean radioactive air

    International Nuclear Information System (INIS)

    Ganz, G.

    1987-01-01

    The author reports a study by the Institutes fuer Klimatechnik and Umweltschutz Giessen that shows that air conditioning systems not only make the atmosphere more comfortable, they also extract dust particles. This cleaning action is also valid for radioactively contaminated air. (G.T.H./Auth.)

  20. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  1. Air pollution meteorology

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Daoo, V J [Environmental Assessment Div., Bhabha Atomic Research Centre, Mumbai (India)

    2002-06-01

    This report is intended as a training cum reference document for scientists posted at the Environmental Laboratories at the Nuclear Power Station Sites and other sites of the Department of Atomic Energy with installations emitting air pollutants, radioactive or otherwise. Since a manual already exists for the computation of doses from radioactive air pollutants, a general approach is take here i.e. air pollutants in general are considered. The first chapter presents a brief introduction to the need and scope of air pollution dispersion modelling. The second chapter is a very important chapter discussing the aspects of meteorology relevant to air pollution and dispersion modelling. This chapter is important because without this information one really does not understand the phenomena affecting dispersion, the scope and applicability of various models or their limitations under various weather and site conditions. The third chapter discusses the air pollution models in detail. These models are applicable to distances of a few tens of kilometres. The fourth chapter discusses the various aspects of meteorological measurements relevant to air pollution. The chapters are followed by two appendices. Apendix A discusses the reliability of air pollution estimates. Apendix B gives some practical examples relevant to general air pollution. It is hoped that the document will prove very useful to the users. (author)

  2. Thermal conditions and perceived air quality in an air-conditioned auditorium

    Science.gov (United States)

    Polednik, Bernard; Guz, Łukasz; Skwarczyński, Mariusz; Dudzińska, Marzenna R.

    2016-07-01

    The study reports measurements of indoor air temperature (T) and relative humidity (RH), perceived air quality (PAQ) and CO2, fine aerosol particle number (PN) and mass (PM1) concentrations in an air conditioned auditorium. The measurements of these air physical parameters have been carried out in the unoccupied auditorium with the air conditioning system switched off (AC off mode) and in the unoccupied and occupied auditorium with the air conditioning system switched off during the night and switched on during the day (AC on/off mode). The average indoor air thermal parameters, CO2 concentration and the PAQ value (in decipols) were elevated, while average PM1 concentration was lower in the AC on/off mode. A statistically significant (p PAQ values and CO2 concentrations (r = 0.66 and r = 0.59, respectively) in that AC mode. A significant negative correlation has been observed between T and PN and PM1 concentrations (r = -0.38 and r = -0.49, respectively). In the AC off mode the above relations between T and the particle concentrations were not that unequivocal. These findings may be of importance as they indicate that in certain AC operation modes the indoor air quality deteriorates along with the variation of the indoor air microclimate and room occupation. This, in turn, may adversely affect the comfort and productivity of the users of air conditioned premises.

  3. CALCULATION OF AIR ION REGIME IN THE CASE OF ARTIFICIAL AIR IONIZATION

    Directory of Open Access Journals (Sweden)

    BILIAIEV M. M.

    2015-10-01

    Full Text Available Purpose. One of the major tasks in the field of labor protection is providing of the necessary qualitative composition of air in the working areas of office and industrial spaces. In order to maintain the necessary air ion level in the air space premises, the artificial ionization of air is used often in the premises. At present in Ukraine analytical model are used for the calculation of air ion regime in premises, influencing on the formation process of air ions concentration field. An alternative solution is the use of CFD models, developing including the air jets aerodynamics in the premise, the presence of furniture, equipment, transfer of ions under an electric field, and other physical factors, determining intensity and shape of air ions concentration field in the premise. Methodology. Influence of air flow was taken into account in the development of CFD models for calculation of air ion regime in the apartment, caused by operation of ventilation, diffusion, electric field impact, as well as the interaction of different polarity ions with each other, and their interaction with dust particles. The proposed model of calculation of air ion regime in premises based on the use of aerodynamics, electrostatics and mass transfer levels. This model allows operatively to calculate air ions concentration field with the influence of the walls, floor, ceiling and obstacles on the process of air ions dispersion, the specific location of different polarity ions emission and their interaction in the premise and work areas in conditions of artificial air ionization. Results. The calculated data were obtained and on their base could be estimated the concentration of air ion anywhere in the premise with artificial air ionization. Ions concentration field, being calculated using this CFD model, as concentration field isolines is presented. Originality. The results of the air ion regime calculation in the premise are presented, based on numerical 2D CFD model

  4. Danger in the Air: Air Pollution and Cognitive Dysfunction.

    Science.gov (United States)

    Cipriani, Gabriele; Danti, Sabrina; Carlesi, Cecilia; Borin, Gemma

    2018-01-01

    Clean air is considered to be a basic requirement for human health and well-being. To examine the relationship between cognitive performance and ambient pollution exposure. Studies were identified through a systematic search of online scientific databases, in addition to a manual search of the reference lists from the identified papers. Air pollution is a multifaceted toxic chemical mixture capable of assaulting the central nervous system. Despite being a relatively new area of investigation, overall, there is mounting evidence implicating adverse effects of air pollution on cognitive function in both adults and children. Consistent evidence showed that exposure to air pollution, specifically exposure to particulate matter, caused poor age-related cognitive performance. Living in areas with high levels of air pollution has been linked to markers of neuroinflammation and neuropathology that are associated with neurodegenerative conditions such as Alzheimer's disease-like brain pathologies.

  5. Air Sensor Toolbox

    Science.gov (United States)

    Air Sensor Toolbox provides information to citizen scientists, researchers and developers interested in learning more about new lower-cost compact air sensor technologies and tools for measuring air quality.

  6. CityAir app: Mapping air-quality perception using people as sensors

    Science.gov (United States)

    Castell, Nuria; Fredriksen, Mirjam; Cole-Hunter, Thomas; Robinson, Johanna; Keune, Hans; Nieuwenhuijsen, Mark; Bartonova, Alena

    2016-04-01

    Outdoor air pollution is a major environmental health problem affecting all people in developed and developing countries alike. Ambient (outdoor) air pollution in both cities and rural areas was estimated to cause 3.7 million premature deaths worldwide in 2012. In modern society, people are expending an increasing amount of time in polluted urban environments, thus increasing their exposure and associated health responses. Some cities provide information about air pollution levels to their citizens using air quality monitoring networks. However, due to their high cost and maintenance, the density of the monitoring networks is very low and not capable to capture the high temporal and spatial variability of air pollution. Thus, the citizen lacks a specific answer to the question of "how the air quality is in our surroundings". In the framework of the EU-funded CITI-SENSE project the innovative concept of People as Sensors is being applied to the field of outdoor air pollution. This is being done in eight European cities, including Barcelona, Belgrade, Edinburgh, Haifa, Ljubljana, Oslo, Ostrava and Vienna. People as Sensors defines a measurement model, in which measurements are not only taken by hardware sensors, but in which also humans can contribute with their individual "measurements" such as their subjective perception of air quality and other personal observations. In order to collect the personal observations a mobile app, CityAir, has been developed. CityAir allows citizens to rate the air quality in their surroundings with colour at their current location: green if air quality is very good, yellow if air quality is good, orange if air quality is poor and red if air quality is very poor. The users have also the possibility of indicating the source of pollution (i.e. traffic, industry, wood burning) and writing a comment. The information is on-line and accessible for other app users, thus contributing to create an air-quality map based on citizens' perception

  7. Final Environmental Assessment for the First Air Force Air Operations Center, First Air Force Headquarters/Air Force Forces Center, and Highway 98 Overpass at Tyndall Air Force Base, Florida

    Science.gov (United States)

    2004-01-01

    no comments regarding the Draft Environmental Assessment for the First Air Force Operations Center, First Air Force Headquarters/Air Force Forces...COUNCIL ] No Comment BAY - BAY COUNTY No Final Comments Received ENVIRONMENTAL POLICY UNIT - OFFICE OF POLICY AND BUDGET, ENVIRONMENTAL POLICY UNIT NO ...CONSERVATION COMMISSION [ NO COMMENT BY BRIAN BARNETT ON 4/12/04. [STATE - FLORIDA DEPARTMENT OF STATE [ No Comment [TRANSPORTATION - FLORIDA DEPARTMENT

  8. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  9. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  10. Air pollution engineering

    Science.gov (United States)

    Maduna, Karolina; Tomašić, Vesna

    2017-11-01

    Air pollution is an environmental and a social problem which leads to a multitude of adverse effects on human health and standard of human life, state of the ecosystems and global change of climate. Air pollutants are emitted from natural, but mostly from anthropogenic sources and may be transported over long distances. Some air pollutants are extremely stable in the atmosphere and may accumulate in the environment and in the food chain, affecting human beings, animals and natural biodiversity. Obviously, air pollution is a complex problem that poses multiple challenges in terms of management and abatements of the pollutants emission. Effective approach to the problems of air pollution requires a good understanding of the sources that cause it, knowledge of air quality status and future trends as well as its impact on humans and ecosystems. This chapter deals with the complexities of the air pollution and presents an overview of different technical processes and equipment for air pollution control, as well as basic principles of their work. The problems of air protection as well as protection of other ecosystems can be solved only by the coordinated endeavors of various scientific and engineering disciplines, such as chemistry, physics, biology, medicine, chemical engineering and social sciences. The most important engineering contribution is mostly focused on development, design and operation of equipment for the abatement of harmful emissions into environment.

  11. Indoor Air Quality

    Science.gov (United States)

    ... protect yourself and your family. Learn more Air Quality at Work Workers should breathe easy while on the job, but worksites with poor air quality put employees at risk. Healthy air is essential ...

  12. Machine & electrical double control air dryer for vehicle air braking system

    Science.gov (United States)

    Zhang, Xuan; Yang, Liu; Wang, Xian Yan; Tan, Xiao Yan; Wang, Wei

    2017-09-01

    As is known to all, a vehicle air brake system, in which usually contains moisture. To solve the problem, it is common to use air dryer to dry compressed air effectively and completely remove the moisture and oil of braking system. However, the existing air dryer is not suitable for all commercial vehicles. According to the operational status of the new energy vehicles in the initial operating period, the structure design principle of the machine & electric control air dryer is expounded from the aspects of the structure and operating principle, research & development process.

  13. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  14. Photochemical air pollution

    International Nuclear Information System (INIS)

    Te Winkel, B.H.

    1992-01-01

    During periods of severe photochemical air pollution (smog) the industry in the Netherlands is recommended by the Dutch government to strongly reduce the emissions of air pollutants. For the electric power generating companies it is important to investigate the adequacy of this policy. The purpose of this investigation is to determine the contribution of electric power plants to photochemical air pollution and to assess the efficacy of emission reducing measures. A literature survey on the development of photochemical air pollution was carried out and modelled calculations concerning the share of the electric power plants to the photochemical air pollution were executed

  15. Air-water screen

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.I.; Kutepov, A.I.

    1980-12-08

    The air-water screen based on inventor's certificate No. 577364 contains horizontal water and air lines with water and air nozzles. The air line is situated inside the water line eccentrically and contracts it in the area of the nozzle, whose orifices are situated along the line of contact, while the orifices of the water nozzle are situated symmetrically relative to the air orifices and are located at an acute angle to them. To raise the protective properties, on the end of the water line is a lateral nozzle water distributor is an additional nozzle, connected to this container.

  16. THE USE OF AIR LAYERS IN BUILDING ENVELOPES FOR ENERGY SAVING DURING AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available Since there are no large natural energy resources in Belarus, energy savings ought to be a point of the special attention. With this regard it is important to develop modern ways of savings during the process of air conditioning inside new buildings with an air layer in the enclosure, especially in translucent ones. The system of ventilation of air layers in the enclosure of a building has been introduced in which air movement is caused by the gravitational and aerodynamic forces. It makes it possible to arrange further ventilation – a natural, forced or a hybrid one. With the purpose of increasing and streamlining natural draught the partitions are used separating the different parts of air layers. For natural ventilation with the use of gravitational forces the holes in the upper and lower parts of the partitions between adjacent air layers are applied. Natural ventilation in the holes of the partitions is regulated by movable shutters, blinds or other adjusting devices. For combined or forced air exchange between adjacent zones of air layers fans are used pumping air from the air layer zones with a higher temperature to zones of air layers with lower temperature and vice versa. When air exchange is forced, in order to intensify the infiltration of air into zones of air layers jets are laid on a hard surface. In order to cool a multi-layered enclosure of a building, where the movement of air between the air layers (that have been formed by internal partitions is being fulfilled by a natural, forced or combined mode, a part of the air or the total air processed inside the building (i.e. conditioned or non-conditioned air cooler as compared with the outside one is being sent to these strata. Combined or forced flow of the air processed inside the building into the air layers is done through the ducts associated with the output channels of the air conditioners. The internal partitions are equipped with the air valve hole.

  17. CFD Parametric Studies for Global Performance Improvement of Open Refrigerated Display Cabinets

    Directory of Open Access Journals (Sweden)

    Pedro Dinis Gaspar

    2012-01-01

    Full Text Available A detailed CFD modelling of an open refrigerated display cabinet has been formulated in a previous study. Some modifications are introduced in order to perform parametric studies dealing with low-cost geometrical and functional characteristics for improvement of the global performance and energy efficiency. The parametric studies are devoted to the analysis of the thermal response and behaviour inside the food conservation space influenced by (1 air flow rate through the evaporator heat exchanger; (2 air curtain behaviour; (3 hole dimensions and distribution of the back panel; (4 discharge and return grilles angles; and (5 flow deflectors inside the internal duct. The analysis of the numerical predictions from the parametric studies allows the development of an optimized model for the conception of an open refrigerated display cabinet with a more adequate configuration. The numerical predictions of the optimized model show lower product temperature and reduced electrical energy consumption, allowing the improvement of the food safety and the energy rationalization of the refrigeration equipment.

  18. Simple air collectors for preheating fresh air

    NARCIS (Netherlands)

    Hensen, J.L.M.; Wit, de M.H.; Ouden, den C.

    1984-01-01

    In dwellings with mechanical ventilation systems the fresh air can easily be preheated by means of simple solar air systems. These can be an integral part of the building facade or roof and the costs are expected to be low. By means of computer experiments a large number of systems were evaluated.

  19. Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser

    Energy Technology Data Exchange (ETDEWEB)

    Hajidavalloo, E.; Eghtedari, H. [Mechanical Engineering Department, Shahid Chamran University, Golestan St., Ahvaz (Iran)

    2010-08-15

    Increasing the coefficient of performance of air conditioner with air-cooled condenser is a challenging problem especially in area with very hot weather conditions. Application of evaporatively cooled air condenser instead of air-cooled condenser is proposed in this paper as an efficient way to solve the problem. An evaporative cooler was built and coupled to the existing air-cooled condenser of a split-air-conditioner in order to measure its effect on the cycle performance under various ambient air temperatures up to 49 C. Experimental results show that application of evaporatively cooled air condenser has significant effect on the performance improvement of the cycle and the rate of improvement is increased as ambient air temperature increases. It is also found that by using evaporatively cooled air condenser in hot weather conditions, the power consumption can be reduced up to 20% and the coefficient of performance can be improved around 50%. More improvements can be expected if a more efficient evaporative cooler is used. (author)

  20. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...... floor heating system was simulated, the cooler ventilation air introduced to the room mixed well and created uniform conditions with a ventilation effectiveness of about 1.......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...

  1. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  2. Hazardous air pollutant handbook: measurements, properties, and fate in ambient air

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, C.W. (ed.); Gordon, S.M.; Kelly, T.J.; Holdren, M.W.; Mukund, R. [Battelle, Columbus, OH (United States)

    2002-07-01

    Focussing on the 188 hazardous air pollutants (HAPs) identified in the Title III of the US Clean Air Act Amendments, this work reviews the methods used to identify, measure, and locate the presence of toxics in ambient air. After a classification and characterization of the HAPs, the current status of ambient measurement methods are surveyed and categorized according to applicable, likely, and potential methods. The results of studies of ambient air concentrations of the HAPs are presented. Methods used to study atmospheric transformations of toxic air pollutants are reviewed and the concept of atmospheric lifetimes of HAPs is discussed.

  3. Controlled air incineration

    International Nuclear Information System (INIS)

    Seitz, K.A.

    1991-01-01

    From 1960 to 1970, incineration was recognized as an economical method of solid waste disposal with many incinerators in operation through the country. During this period a number of legislation acts began to influence the solid waste disposal industry, namely, the Solid Waste Disposal Act of 1965; Resource Conservation Recovery Act (RCRA) of 1968; Resource Recovery Act of 1970; and Clean Air Act of 1970. This period of increased environmental awareness and newly created regulations began the closure of many excess air incineration facilities and encouraged the development of new controlled air, also known as Starved-Air incinerator systems which could meet the more stringent air emission standards without additional emission control equipment. The Starved-Air technology initially received little recognition because it was considered unproven and radically different from the established and accepted I.I.A. standards. However, there have been many improvements and developments in the starved-air incineration systems since the technology was first introduced and marketed, and now these systems are considered the proven technology standard

  4. Oxidation behavior of stainless steel 430 and 441 at 800 C in single (air/air) and dual atmosphere (air/hydrogen) exposures

    Energy Technology Data Exchange (ETDEWEB)

    Rufner, J.; Gannon, P.; White, P.; Deibert, M.; Teintze, S. [Chemical and Biological Engineering, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States); Smith, R.; Chen, H. [Physics, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States)

    2008-02-15

    Intermediate temperature ({proportional_to}800 {sup o}C) planar solid oxide fuel cells (SOFCs) allow the use of ferritic stainless steel (FSS) interconnects. SOFC FSS interconnects are used to stack individual cells into series, and are simultaneously exposed to air on the cathode side and fuel on the anode side, creating a 'dual atmosphere' exposure. The thermally grown oxide (TGO) layers on the air side of FSSs 430 and 441 were analyzed as a function of simulated dual atmosphere exposures (moist air/moist hydrogen) for up to 300 h. FSS 430 showed some changes in oxidation behavior, with a slight Fe concentration increase and localized Fe{sub 2}O{sub 3} nodule formation observed in the dual atmosphere TGO layer relative to its single atmosphere (air/air) counterpart. Significantly accelerated and anomalous oxidation was observed with FSS 441 subjected to dual atmosphere exposures compared with air/air exposures. The TGO layer formed on the 441 exposed to air/air was comprised of Mn-rich, Cr and Fe-containing isomorphic spinel surface crystallites, with a Cr{sub 2}O{sub 3} (eskolaite)-based bottom layer, having a total TGO layer thickness of <2{mu} m after 300 h. In contrast, the TGO layer formed on 441 during dual atmosphere exposure was much faster-growing (>6{mu} m in 20 h) and exhibited a continuous, porous Fe{sub 2}O{sub 3}-rich surface layer with a relatively thin (<2{mu} m) sublayer of similar composition to the TGO layer formed during the air/air exposure. Spontaneous TGO layer spallation was also observed for the air side of 441 exposed to dual atmosphere for >100h. The observed oxidation behavior and TGO layer evolution of 441 in both air/air and dual atmosphere are presented, with possible mechanisms and implications discussed. (author)

  5. Air toxics and the 1990 Clean Air Act: Managing trace element emissions

    International Nuclear Information System (INIS)

    Chow, W.; Levin, L.; Miller, M.J.

    1992-01-01

    The US Environmental Protection Agency (EPA) has historically regulated air toxics (hazardous air pollutants) under Section 112 of the Clean Air Act. To date, EPA has established emission standards for 8 hazardous air pollutants (arsenic, asbestos, benzene, beryllium, mercury, radionuclides, coke oven emissions and vinyl chloride). The US electric utility industry was not determined to be a source category requiring regulation for any of the eight chemicals. Of the eight, radionuclides were the last species for which EPA established hazardous emissions standards. In this instance, EPA determined that the risks associated with electric utility fossil fuel power plant emissions were sufficiently low that they should not be regulated. However, the 1990 Clean Air Act Amendments require a new evaluation of the electric utility industry emissions of hazardous air pollutants. This paper summarizes the key features of the air toxics provisions of the Clean Air Act Amendments, describes EPRI's activities on the subject, and provides some preliminary insights from EPRI's research to date

  6. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  7. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    DEFF Research Database (Denmark)

    Nazaroff, W.; Weschler, Charles J.

    2004-01-01

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated...... by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals...... that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which...

  8. Large scale air monitoring: Biological indicators versus air particulate matter

    International Nuclear Information System (INIS)

    Rossbach, M.; Jayasekera, R.; Kniewald, G.

    2000-01-01

    Biological indicator organisms are widely used for monitoring and banking purposes since many years. Although the complexity of the interactions between bioorganisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Direct measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and uniform matrix characteristics of air particulates as a prerequisite for global monitoring of air pollution will be discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300 to 500 g each) from a number of hotels during a period of three to four months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per three months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichen such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Fig and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cr, Zn, and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10). (author)

  9. Air pollution and urban air quality management in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Santosa, Sri J. [Department of Chemistry, Faculty of Mathematics and Natural Sciences, Gadjah Mada University, Yogyakarta (Indonesia); Okuda, Tomoaki; Tanaka, Shigeru [Department of Applied Chemistry, Faculty of Science and Technology, Keio University, Yokohama (Japan)

    2008-06-15

    The trade-led industry and economic development after the Asian financial crisis a decade ago has been accelerated in Indonesia to improve the quality of life of its population. This rapid development of Indonesia was in fact heavily fueled by fossil fuels, especially oil, followed by natural gas and coal. The exploitation of fossil fuel in fueling the development resulted in significant environmental quality degradation. Air pollution is perhaps Indonesia's most severe environmental problem. Industry and transportation were the typical main sources of urban air pollutants. Moreover, Indonesia also failed to reach its original 2005 target for a complete phase-out of leaded gasoline. As a result, the level of Pb together with other pollutants such as CO, NO{sub x}, SO{sub 2}, and total suspended particulates has exceeded or at least approached the designated ambient air quality standards. The urban air pollution will not be lesser in extent, but surely will be more severe in the future. Unfortunately, the capability of the Indonesian authorities to manage the urban air quality is still very limited and the portion of the budget allocated to the improvement of urban air quality is still remarkably low, typically 1% of total. This is why the efforts to enhance the capability to manage the urban air quality could not be handled by the environmental authorities in Indonesia's cities themselves, but outside stimulation in the form of man power, consultant and equipment assistance along with financial support has been very important. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  10. AirCompare

    Data.gov (United States)

    U.S. Environmental Protection Agency — AirCompare contains air quality information that allows a user to compare conditions in different localities over time and compare conditions in the same location at...

  11. 12th Air Force > Home

    Science.gov (United States)

    Force AOR Travel Info News prevnext Slide show 76,410 pounds of food delivered to Haiti 12th Air Force the French Air Force, Colombian Air Force, Pakistan Air Force, Belgian Air Force, Brazilian Air Force

  12. Energy use, air infiltration, and indoor air quality in well-insulated residences

    International Nuclear Information System (INIS)

    Koontz, M.D.; Nagda, N.L.

    1989-01-01

    This paper reports two unoccupied bilevel houses of identical design and construction studied to determine the relationships among air exchange, energy consumption, and indoor air quality. The experimental house was retrofitted to increase building tightness and was equipped with an air-to-air heat exchanger; the control house was kept in its initial state of construction. Infiltration, energy, indoor air quality, and environmental parameters were monitored in both houses before and after the retrofit. It was found that the retrofit decreased air infiltration rates by nearly 25 percent, heating energy savings of 12 to 20 percent were achieved through the retrofit, and among the pollutants monitored, only radon and radon progeny increased in proportion to the reduced infiltration. Similarly, when the heat exchanger was operated, radon and radon progeny were the only pollutants reduced in proportion to the added air exchange

  13. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    Science.gov (United States)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  14. Air pollution

    OpenAIRE

    MacKenbach, JP; Henschel, S; Goodman, P; McKee, M

    2013-01-01

    The human costs of air pollution are considerable in Jordan. According to a report published in 2000 by the World Bank under the Mediterranean Environmental Technical Assistance Program (METAP), approximately 600 people die prematurely each year in Jordan because of urban pollution. 50-90% of air pollution in Jordanian towns is caused by road traffic. Readings taken in 2007 by Jordanian researchers showed that levels of black carbon particles in the air were higher in urban areas (caused by v...

  15. Air quality management: challenges and solutions in delivering air quality action plans

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, C.I.; Longhurst, J.W.S.; Woodfield, N.K.

    2000-07-01

    The Air Quality Strategy for England, Scotland, Wales and Northern Ireland (DETR, 2001) has the aim of showing how improved local air quality in the UK may be delivered. Through a process of reviewing and assessing local air quality in both urban and rural localities, a clear picture is emerging of areas of the UK where air quality objectives are not likely to be met. The next challenge will be the identification of the required actions and new ways of working to achieve specific air quality objectives. The declaration of air quality management areas, where objectives are not predicted to be met by their target years, involves co-ordinated local action and collaborative working, which can only be effective with support across local authority departments and external stake holders. This paper provides a background to the relevant legislation underpinning, local air quality management and summarises the review and assessment process. It then comments on future directions in relation to the designation of Air Quality Management Areas and considers the requirements of action plans to deliver the goal of cleaner air in the UK. It is concluded that the UK has developed a highly sophisticated system of air quality management over a relatively short period of time, and with it has brought a new way of local authority working. The challenge of the next stage of the process is likely to be in implementing cost effective and proportional solutions to identified problems at the local level. (Author)

  16. Air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, W; Mainwaring, S J

    1984-01-01

    This book deals with the nature of air pollution. The numerous sources of unwanted gases and dust particles in the air are discussed. Details are presented of the effects of pollutants on man, animals, vegetation and on inanimate materials. Methods used to measure, monitor and control air pollution are presented. The authors include information on the socio-economic factors which impinge on pollution control and on the problems the future will bring as methods of generating energy change and industries provide new sources of pollutants.

  17. Reshocks, rarefactions, and the generalized Layzer model for hydrodynamic instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Mikaelian, K O

    2008-06-10

    We report numerical simulations and analytic modeling of shock tube experiments on Rayleigh-Taylor and Richtmyer-Meshkov instabilities. We examine single interfaces of the type A/B where the incident shock is initiated in A and the transmitted shock proceeds into B. Examples are He/air and air/He. In addition, we study finite-thickness or double-interface A/B/A configurations like air/SF{sub 6}/air gas-curtain experiments. We first consider conventional shock tubes that have a 'fixed' boundary: A solid endwall which reflects the transmitted shock and reshocks the interface(s). Then we focus on new experiments with a 'free' boundary--a membrane disrupted mechanically or by the transmitted shock, sending back a rarefaction towards the interface(s). Complex acceleration histories are achieved, relevant for Inertial Confinement Fusion implosions. We compare our simulation results with a generalized Layzer model for two fluids with time-dependent densities, and derive a new freeze-out condition whereby accelerating and compressive forces cancel each other out. Except for the recently reported failures of the Layzer model, the generalized Layzer model and hydrocode simulations for reshocks and rarefactions agree well with each other, and remain to be verified experimentally.

  18. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  19. Pollution prevention for cleaner air: EPA's air and energy engineering research laboratory

    International Nuclear Information System (INIS)

    Shaver, E.M.

    1992-01-01

    The article discusses the role of EPA's Air and Energy Engineering Research Laboratory (AEERL) in pollution prevention research for cleaner air. For more than 20 years, AEERL has been conducting research to identify control approaches for the pollutants and sources which contribute to air quality problems. The Laboratory has successfully developed and demonstrated cost-effective sulfur dioxide, nitrogen oxides, and particulate control technologies for fossil fuel combustion sources. More recently, it has expanded its research activities to include indoor air quality, radon, organic control, stratospheric ozone depletion, and global warming. AEERL also develops inventories of air emissions of many types. Over the last several years, it has made substantial efforts to expand research on pollution prevention as the preferred choice for air emissions reduction

  20. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Energy Technology Data Exchange (ETDEWEB)

    El-Awad, Mohamed M. [Mechanical Engineering Department, the University of Khartoum, P.O. Box 321 Khartoum (Sudan)

    2011-07-01

    The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min) air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  1. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  2. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  3. Air Quality of Beijing and Impacts of the New Ambient Air Quality Standard

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2015-08-01

    Full Text Available Beijing has been publishing daily reports on its air quality since 2000, and while the air pollution index (API shows that the air quality has improved greatly since 2000, this is not the perception of Beijing’s residents. The new national ambient air quality standard (NAAQS-2012, which includes the monitoring of PM2.5, has posed stricter standards for evaluating air quality. With the new national standard, the air quality in Beijing is calculated using both NAAQS-2012 and the previous standard. The annual attainment rate has dropped from 75.5% to 50.7%. The spatial analysis of air quality shows that only a background station could attain the national standard, while urban and suburban stations exceed the national standard. Among the six pollutants included in the NAAQS-2012, PM2.5 is the major contributor to the air quality index (AQI comparing with the five other pollutants. The results indicate that under previous NAAQS without PM2.5 monitoring, the air quality has improved greatly in the past decade.  By considering PM2.5, the air quality attainment has dropped greatly. Furthermore, a great effort is needed for local government to bring down the PM2.5 concentration.

  4. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  5. Influence of local air velocity from air conditioner evaluated by salivary and skin biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Masaki; Takahashi, Takayuki; Yoshino, Yuichiro; Sasaki, Makoto [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Nishimiya, Hajime [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2010-11-15

    The purpose of this paper is to reveal both the psychosomatic and the physical effects of local air velocity from an air conditioner using biomarkers which can be collected noninvasively. Salivary {alpha}-amylase activity (SAA) and salivary cortisol were used as the indexes of psychosomatic effects. The total protein (TP) collected from stratum corneum was used as an index of the physical condition of dry skin. A continuous experiment over a 5 days period in summer was conducted using 8 healthy young male adults for 2-types of airflow conditioners, a whole ceiling-type air conditioner (without local air velocity) and a normal-type air conditioner (with local air velocity). The subjects felt cool, windy, dry and uncomfortable when under the normal-type air conditioner as determined in a subjective evaluation. The SAA under the normal-type air conditioner fluctuated more widely than with the whole ceiling-type air conditioner. The level of salivary cortisol decreased more in a day under the normal-type air conditioner than with the whole ceiling-type air conditioner. These results showed that reducing local air velocity may provide more healthy psychosomatic conditions over the long-term. Moreover, the TP of a drying-exposed skin area showed a significant change during this experiment whereas the TP of drying-protected area was relatively unchanged. It was indicated that one week's exposure to local air velocity conditions possibly influences the drying of facial skin. Thus, air movement at low velocity can be provides more comfortable conditions not only psychosomatically but also physically. (author)

  6. Beyond Close Air Support. Forging a New Air-Ground Partnership

    Science.gov (United States)

    2005-01-01

    the "eth- nic cleansing." Despite months of effort, air attacks did little damage to Serb forces. Those in Kosovo not only survived, they even...Blue Moon: Airmen in Theater Command, CADRE Paper No. 7, Air University Press, Maxwell Air Force Base, 2000. Biddle , Stephen, Afghanistan and the...Future of Warfare: Implications for Army and Defense Policy, Carlisle, PA: Strategic Studies Institute, U.S. Army War College, 2002. Biddle , Stephen

  7. Air Quality | Air Quality Planning & Standards | US EPA

    Science.gov (United States)

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  8. Help From Above: Air Force Close Air Support of the Army. 1946-1973

    Science.gov (United States)

    2003-01-01

    support as but one ele- ment within a larger package called tactical air support challenges the researcher . Even though close air support is but one of...of the prewar gaps in the close air support picture. Of all the close air support developments that emerged from the war, however, airmen looked upon...to reduce the AAF’s impressive World War II close air support capabilities to a token force in the short space of five years, these budgetary

  9. Air lasing

    CERN Document Server

    Cheng, Ya

    2018-01-01

    This book presents the first comprehensive, interdisciplinary review of the rapidly developing field of air lasing. In most applications of lasers, such as cutting and engraving, the laser source is brought to the point of service where the laser beam is needed to perform its function. However, in some important applications such as remote atmospheric sensing, placing the laser at a convenient location is not an option. Current sensing schemes rely on the detection of weak backscattering of ground-based, forward-propagating optical probes, and possess limited sensitivity. The concept of air lasing (or atmospheric lasing) relies on the idea that the constituents of the air itself can be used as an active laser medium, creating a backward-propagating, impulsive, laser-like radiation emanating from a remote location in the atmosphere. This book provides important insights into the current state of development of air lasing and its applications.

  10. Microfluidic liquid-air dual-gradient chip for synergic effect bio-evaluation of air pollutant.

    Science.gov (United States)

    Liu, Xian-Jun; Hu, Shan-Wen; Xu, Bi-Yi; Zhao, Ge; Li, Xiang; Xie, Fu-Wei; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-05-15

    In this paper, a novel prototype liquid-air dual gradient chip is introduced, which has paved the way for effective synergic effect bio-evaluation of air pollutant. The chip is composed of an array of the agarose liquid-air interfaces, top air gradient layer and bottom liquid gradient layer. The novel agarose liquid-air interface allows for non-biased exposure of cells to all the substances in the air and diffusive interactions with the liquid phase; while the dual liquid-air gradient provides powerful screening abilities, which well reduced errors, saved time and cost from repeated experiment. Coupling the two functions, the chip subsequently facilitates synergic effect evaluation of both liquid and air factors on cells. Here cigarette smoke was taken as the model air pollutant, and its strong synergic effects with inflammatory level of A549 lung cancer cells on their fate were successfully quantified for the first time. These results well testified that the proposed dual-gradient chip is powerful and indispensable for bio-evaluation of air pollutant. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Long-term Changes in Extreme Air Pollution Meteorology and the Implications for Air Quality.

    Science.gov (United States)

    Hou, Pei; Wu, Shiliang

    2016-03-31

    Extreme air pollution meteorological events, such as heat waves, temperature inversions and atmospheric stagnation episodes, can significantly affect air quality. Based on observational data, we have analyzed the long-term evolution of extreme air pollution meteorology on the global scale and their potential impacts on air quality, especially the high pollution episodes. We have identified significant increasing trends for the occurrences of extreme air pollution meteorological events in the past six decades, especially over the continental regions. Statistical analysis combining air quality data and meteorological data further indicates strong sensitivities of air quality (including both average air pollutant concentrations and high pollution episodes) to extreme meteorological events. For example, we find that in the United States the probability of severe ozone pollution when there are heat waves could be up to seven times of the average probability during summertime, while temperature inversions in wintertime could enhance the probability of severe particulate matter pollution by more than a factor of two. We have also identified significant seasonal and spatial variations in the sensitivity of air quality to extreme air pollution meteorology.

  12. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  13. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  14. 14 CFR 234.13 - Reports by air carriers on incidents involving animals during air transport.

    Science.gov (United States)

    2010-01-01

    ... involving animals during air transport. 234.13 Section 234.13 Aeronautics and Space OFFICE OF THE SECRETARY... REPORTS § 234.13 Reports by air carriers on incidents involving animals during air transport. (a) Any air... during air transport provided by the air carrier. (b) The report shall be made in the form and manner set...

  15. Effects of open-air temperature on air temperature inside biological safety cabinet.

    Science.gov (United States)

    Umemura, Masayuki; Shigeno, Katsuro; Yamamura, Keiko; Osada, Takashi; Soda, Midori; Yamada, Kiyofumi; Ando, Yuichi; Wakiya, Yoshifumi

    2011-02-14

    In Japan, biological safety cabinets (BSCs) are normally used by medical staff while handling antineoplastic agents. We have also set up a class II B2 BSC at the Division of Chemotherapy for Outpatients. The air temperature inside this BSC, however, decreases in winter. We assumed that this decrease is caused by the intake of open-air. Therefore, we investigated the effects of low open-air temperature on the BSC temperature and the time of admixtures of antineoplastic agents. The studies were conducted from January 1 to March 31, 2008. The outdoor air temperature was measured in the shade near the intake nozzle of the BSC and was compared with the BSC temperature. The correlation between the outdoor air temperature and the BSC temperature, the dissolution time of cyclophosphamide (CPA) and gemcitabine (GEM), and accurate weight measurement of epirubicin (EPI) solution were investigated for low and normal BSC temperatures. The BSC temperature was correlated with the open-air temperature for open-air temperatures of 5-20°C (p air is drawn from outdoors. We showed that the BSC temperature affects the dissolution rate of antineoplastic agents. Further, we suggested that the BSC temperature drop might delay the affair of the admixtures of antineoplastic agents and increase the waiting time of outpatients for chemotherapy.

  16. Comparison of desiccant air conditioning systems with different indirect evaporative air coolers

    International Nuclear Information System (INIS)

    Pandelidis, Demis; Anisimov, Sergey; Worek, William M.; Drąg, Paweł

    2016-01-01

    Highlights: • A numerical study of desiccant air conditioning systems is presented. • The ε-NTU model is used for the analysis. • Different arrangements of the desiccant systems were compared. • The systems were compared under different operating conditions. - Abstract: This paper presents a numerical analysis of three desiccant air-conditioning systems equipped with different indirect evaporative air coolers: (1) the cross-flow Maisotsenko cycle heat and mass exchanger (HMX), (2) the regenerative counter-flow Maisotsenko cycle heat and mass exchanger and (3) the standard cross-flow evaporative air cooler. To analyze the desiccant wheel and the indirect evaporative air coolers, the modified ε-NTU-model was used. The simulations were performed under assumption that the desiccant wheel is regenerated with air heated to relatively low temperature values (50–60 °C), which can be produced with solar panels in typical moderate climatic conditions. It was established that the main advantage of the presented solutions is that they can provide comfort conditions even with less effective dehumidification. The different systems were compared under variable selected operational factors (i.e. inlet air temperature, humidity and regeneration air temperature). The analysis allowed establishing the advantages and disadvantages of presented solutions and allowed estimating their application potential.

  17. A review of air exchange rate models for air pollution exposure assessments.

    Science.gov (United States)

    Breen, Michael S; Schultz, Bradley D; Sohn, Michael D; Long, Thomas; Langstaff, John; Williams, Ronald; Isaacs, Kristin; Meng, Qing Yu; Stallings, Casson; Smith, Luther

    2014-11-01

    A critical aspect of air pollution exposure assessments is estimation of the air exchange rate (AER) for various buildings where people spend their time. The AER, which is the rate of exchange of indoor air with outdoor air, is an important determinant for entry of outdoor air pollutants and for removal of indoor-emitted air pollutants. This paper presents an overview and critical analysis of the scientific literature on empirical and physically based AER models for residential and commercial buildings; the models highlighted here are feasible for exposure assessments as extensive inputs are not required. Models are included for the three types of airflows that can occur across building envelopes: leakage, natural ventilation, and mechanical ventilation. Guidance is provided to select the preferable AER model based on available data, desired temporal resolution, types of airflows, and types of buildings included in the exposure assessment. For exposure assessments with some limited building leakage or AER measurements, strategies are described to reduce AER model uncertainty. This review will facilitate the selection of AER models in support of air pollution exposure assessments.

  18. Railways: Gateways Between East and West in Europe

    Directory of Open Access Journals (Sweden)

    Hansjorg Kuster

    2003-07-01

    Full Text Available Railways have connected various far-flung parts of Europefor much of the last two centuries. Recent years, however, haveseen a decline in direct international connections. This is not somuch due to political developments (the Iron Curtain ceased toexist during the period in question, but rather technical advancesthat have resulted in the development of high-speed networksspecific to various countries. Problems associated withthe use of different gauges, and also electrical and sophisticatedelectronic systems in individual European countries have resultedin high-speed trains being confined mainly to individualstates. During the next years, it is highly desirable to re-establishan international European train or Transrapid network to avoidroad and air-traffic chaos as European integration proceedswith the planned eastwards expansion of the European Union.

  19. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  20. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  1. Integrating air-related health surveillance into air quality management: perceptions and practicalities

    CSIR Research Space (South Africa)

    Wright, C

    2012-06-01

    Full Text Available Health surveillance is presently not an integral part of air quality management in South Africa, although ambient air pollution standards are derived from health effects of personal exposure. In a survey to air quality officials and environmental...

  2. Analysis of Direct Outdoor Air Cooling Efficency for Combined Variable Air Volume Air-conditioning System in Stores in Cold Climates of China

    OpenAIRE

    Luo, Zhiwen

    2006-01-01

    Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive ...

  3. Local Air Quality Conditions and Forecasts

    Science.gov (United States)

    ... Monitor Location Archived Maps by Region Canada Air Quality Air Quality on Google Earth Links A-Z About AirNow AirNow International Air Quality Action Days / Alerts AirCompare Air Quality Index (AQI) ...

  4. AIR NCO's AND AIRMEN

    African Journals Online (AJOL)

    D.F.C. o Proceeded to Cape Town 9:5:22. Left Cape Town for. African Protectorate 25:2:22. J Left for South West African Protectorate 25:2:22. [ Left for South West African Protectorate. 1:6:22. Colonel: Director of Air Services. Air Directorate. 6th June 1922. SOUTH AFRICAN AIR FORCE. NOMINAL ROLL OF AIR W.O.'s,.

  5. Air quality

    International Nuclear Information System (INIS)

    1995-01-01

    This chapter of the 'Assessment of the state of the environment in Lebanon' describes the air quality and identifies the most important air quality issues. Baseline information about the factors affecting dispersion and the climate of Lebanon presents as well and overall estimation of total emissions in Lebanon. Emissions from vehicles, electricity and power plants generation are described. Industrial emitters of air pollutants are described for each kind of industry i.e.cement plants, Selaata fertilizer factory, sugar-beet factory, refineries and for those derived from the use of leaded fuel . Impact of economic and human activities on air quality in Lebanon (especially in Beirut and Tripoli) are quantified by quantities of CO 2 , SO 2 , NO x , total suspended particulates(TSP), deposition and their environmental effects on health. In abscence of emissions monitoring, data available are expressed in terms of fuel use, output and appropriate empirical factors, national output and workfores sizes. Finally key issues and some potential mitigation /management approaches are presented

  6. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  7. Clearing the air. Air quality modelling for policy support

    NARCIS (Netherlands)

    Hendriks, C.

    2017-01-01

    The studies presented in this thesis were performed to provide policy makers with more accurate information about the sources of air pollution and the possible consequences of future developments on air quality. This enables policy makers to make better informed decisions when formulating policies

  8. 77 FR 30087 - Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards

    Science.gov (United States)

    2012-05-21

    ... and 81 Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards; Implementation of the 2008 National Ambient Air Quality Standards for Ozone: Nonattainment Area Classifications...-9668-2] RIN 2060-AP37 Air Quality Designations for the 2008 Ozone National Ambient Air Quality...

  9. Applications Using AIRS Data

    Science.gov (United States)

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  10. Significance of air humidity and air velocity for fungal spore release into the air

    Science.gov (United States)

    Pasanen, A.-L.; Pasanen, P.; Jantunen, M. J.; Kalliokoski, P.

    Our previous field studies have shown that the presence of molds in buildings does not necessarily mean elevated airborne spore counts. Therefore, we investigated the release of fungal spores from cultures of Aspergillus fumigatus, Penicillium sp. and Cladosporium sp. at different air velocities and air humidities. Spores of A. fumigatus and Penicillium sp. were released from conidiophores already at air velocity of 0.5 ms -1, whereas Cladosporium spores required at least a velocity of 1.0 ms -1. Airborne spore counts of A. fumigatus and Penicillium sp. were usually higher in dry than moist air, being minimal at relative humidities (r.h.) above 70%, while the effect of r.h. on the release of Cladosporium sp. was ambivalent. The geometric mean diameter of released spores increased when the r.h. exceeded a certain level which depends on fungal genus. Thus, spores of all three fungi were hygroscopic but the hygroscopicity of various spores appeared at different r.h.-ranges. This study indicates that spore release is controlled by external factors and depends on fungal genus which can be one reason for considerable variation of airborne spore counts in buildings with mold problems.

  11. The microbiological quality of air improves when using air conditioning systems in cars.

    Science.gov (United States)

    Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F

    2010-06-01

    Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.

  12. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  13. Air pollution knows no boundaries: defining air catchment areas and making sense of physical and political boundaries in air quality management

    CSIR Research Space (South Africa)

    Scott, G

    2005-10-01

    Full Text Available Topics under discussion: Scales of transport and turbulence in the atmosphere; Examples of global, regional and local scale transports – concepts of an “air catchment”; Defining air quality management zones - international practice; Defining air...

  14. Kinetics of NO formation and decay in nanosecond pulse discharges in Air, H2-Air, and C2H4-Air mixtures

    International Nuclear Information System (INIS)

    Burnette, David; Shkurenkov, Ivan; Adamovich, Igor V; Lempert, Walter R

    2016-01-01

    Time-resolved, absolute NO and N atom number densities are measured by NO Laser Induced Fluorescence (LIF) and N Two-Photon Absorption LIF in a diffuse plasma filament, nanosecond pulse discharge in dry air, hydrogen-air, and ethylene-air mixtures at 40 Torr, over a wide range of equivalence ratios. The results are compared with kinetic modeling calculations incorporating pulsed discharge dynamics, kinetics of vibrationally and electronically excited states of nitrogen, plasma chemical reactions, and radial transport. The results show that in air afterglow, NO decay occurs primarily by the reaction with N atoms, NO  +  N  →  N 2   +  O. In the presence of hydrogen, this reaction is mitigated by reaction of N atoms with OH, N  +  OH  →  NO  +  H, resulting in significant reduction of N atom number density in the afterglow, additional NO production, and considerably higher NO number densities. In fuel-lean ethylene-air mixtures, a similar trend (i.e. N atom concentration reduction and NO number density increase) is observed, although [NO] increase on ms time scale is not as pronounced as in H 2 -air mixtures. In near-stoichiometric and fuel-lean ethylene-air mixtures, when N atom number density was below detection limit, NO concentration was measured to be lower than in air plasma. These results suggest that NO kinetics in hydrocarbon-air plasmas is more complex compared to air and hydrogen-air plasmas, additional NO reaction pathways may well be possible, and their analysis requires further kinetic modeling calculations. (paper)

  15. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    Directory of Open Access Journals (Sweden)

    Daniela Pinheiro da Silva

    2013-10-01

    Full Text Available Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acquired infections – HAI – as the air can be a potential source of infection, as well as assess the exposure of professionals and patients to different pollutants. Material and Methods: A literature review was performed in the LILACS, MEDLINE, SCIELO, SCIENCE DIRECT databases, CAPES thesis database and Ministry of Health – Brazil, including studies published between 1982 and 2008. The literature search was grouped according to the thematic focus, as follows: ventilation, maintenance and cleaning of systems that comprehend the environmental quality standard. Discussion and Conclusion: Outbreaks of hospital-acquired infections associated with Aspergillus, Acinetobacter, Legionella, and other genera such as Clostridium and Nocardia, which were found in air conditioners, were observed, thus indicating the need for air-conditioning quality control in these environments.

  16. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  17. Air pollution control in India

    International Nuclear Information System (INIS)

    Jain, S.K.

    1995-01-01

    Prior to rapid spurt in industrialization in India, people were used to inhale pure air containing about 78% nitrogen, 21% oxygen and some carbon dioxide. But afterwards this composition of pure air was disturbed as a result of increased economic activities. Air, now a days also contains sulphur dioxide, carbon monoxide, nitrogen oxides etc., etc. which are extremely harmful for human health. Virulence of air pollution was realised in late eighties after Bhopal Gas Tragedy (BGT) and an effective air quality management started taking shape in India afterwards. The basic components of air quality management are legislation and regulations, emission inventory, air quality standards and monitoring, air dispersion models and installation of pollution control equipment which are being discussed in this paper. (author). 15 refs., 5 tabs

  18. Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange

    Science.gov (United States)

    Haynes, Brian D.

    2015-01-01

    Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange is a two-year research effort to visualize the U. S. aviation industry at a point 50 years in the future, and to define potential communication solutions to meet those future data exchange needs. The research team, led by XCELAR, was tasked with identifying future National Airspace System (NAS) scenarios, determining requirements and functions (including gaps), investigating technical and business issues for air, ground, & air-to-ground interactions, and reporting on the results. The project was conducted under technical direction from NASA and in collaboration with XCELAR's partner, National Institute of Aerospace, and NASA technical representatives. Parallel efforts were initiated to define the information exchange functional needs of the future NAS, and specific communication link technologies to potentially serve those needs. Those efforts converged with the mapping of each identified future NAS function to potential enabling communication solutions; those solutions were then compared with, and ranked relative to, each other on a technical basis in a structured analysis process. The technical solutions emerging from that process were then assessed from a business case perspective to determine their viability from a real-world adoption and deployment standpoint. The results of that analysis produced a proposed set of future solutions and most promising candidate technologies. Gap analyses were conducted at two points in the process, the first examining technical factors, and the second as part of the business case analysis. In each case, no gaps or unmet needs were identified in applying the solutions evaluated to the requirements identified. The future communication solutions identified in the research comprise both specific link technologies and two enabling technologies that apply to most or all specific links. As a result, the research resulted in a new analysis approach, viewing the

  19. Iron-Air Rechargeable Battery

    Science.gov (United States)

    Narayan, Sri R. (Inventor); Prakash, G.K. Surya (Inventor); Kindler, Andrew (Inventor)

    2014-01-01

    Embodiments include an iron-air rechargeable battery having a composite electrode including an iron electrode and a hydrogen electrode integrated therewith. An air electrode is spaced from the iron electrode and an electrolyte is provided in contact with the air electrode and the iron electrodes. Various additives and catalysts are disclosed with respect to the iron electrode, air electrode, and electrolyte for increasing battery efficiency and cycle life.

  20. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  1. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  2. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  3. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  4. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  5. Air Pollution and Stroke.

    Science.gov (United States)

    Lee, Kuan Ken; Miller, Mark R; Shah, Anoop S V

    2018-01-01

    The adverse health effects of air pollution have long been recognised; however, there is less awareness that the majority of the morbidity and mortality caused by air pollution is due to its effects on the cardiovascular system. Evidence from epidemiological studies have demonstrated a strong association between air pollution and cardiovascular diseases including stroke. Although the relative risk is small at an individual level, the ubiquitous nature of exposure to air pollution means that the absolute risk at a population level is on a par with "traditional" risk factors for cardiovascular disease. Of particular concern are findings that the strength of this association is stronger in low and middle income countries where air pollution is projected to rise as a result of rapid industrialisation. The underlying biological mechanisms through which air pollutants exert their effect on the vasculature are still an area of intense discussion. A greater understanding of the effect size and mechanisms is necessary to develop effective strategies at individual and policy levels to mitigate the adverse cardiovascular effects of air pollution.

  6. Air Quality at Your Street

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Becker, Thomas; Ketzel, Matthias

    Citizens are frequently concerned about the air quality where they live, where they go to work, where their children go to kindergarten or where they want to move to. Municipalities may also have an interest in location based air quality information e.g. in relation to screening of complaints from...... concerned citizents, or in the context of localization of institutions, etc. The purpose of the project ‘Air Quality at Your Street’ is to create interactive air quality maps on the internet using webGIS to illustrate the geographical variation of air quality in Denmark for selected health related air...... pollutants. The maps show annual means of NO2, PM2.5 or PM10 for 2012. The user interface presents modelled air quality data on a map where the user can select map view, pan, zoom in and out, etc. It is also possible to get the air quality for a particular address by entering a specific address. Air quality...

  7. Optimizing the Air Dissolution Parameters in an Unpacked Dissolved Air Flotation System

    Directory of Open Access Journals (Sweden)

    Adam Dassey

    2011-12-01

    Full Text Available Due to the various parameters that influence air solubility and microbubble production in dissolved air flotation (DAF, a multitude of values that cover a large range for these parameters are suggested for field systems. An unpacked saturator and an air quantification unit were designed to specify the effects of power, pressure, temperature, hydraulic retention time, and air flow on the DAF performance. It was determined that a pressure of 621 kPa, hydraulic retention time of 18.2 min, and air flow of 8.5 L/h would be the best controlled parameters for maximum efficiency in this unit. A temperature of 7 °C showed the greatest microbubble production, but temperature control would not be expected in actual application. The maximum microbubble flow from the designed system produced 30 mL of air (±1.5 per L of water under these conditions with immediate startup. The maximum theoretical dissolved air volume of 107 mL (±6 was achieved at a retention time of 2 h and a pressure of 621 kPa. To isolate and have better control over the various DAF operational parameters, the DAF unit was operated without the unsaturated flow stream. This mode of operation led to the formation of large bubbles at peak bubble production rates. In a real-world application, the large bubble formation will be avoided by mixing with raw unsaturated stream and by altering the location of dissolved air output flow.

  8. Health Effects of Air Pollution

    Science.gov (United States)

    ... Health effects of air pollution Health effects of air pollution Breathing air that is not clean can hurt ... important to know about the health effects that air pollution can have on you and others. Once you ...

  9. Interactions between particulate air pollution and temperature in air pollution mortality time series studies

    International Nuclear Information System (INIS)

    Roberts, Steven

    2004-01-01

    In many community time series studies on the effect of particulate air pollution on mortality, particulate air pollution is modeled additively. In this study, we investigated the interaction between daily particulate air pollution and daily mean temperature in Cook County, Illinois and Allegheny County, Pennsylvania, using data for the period 1987-1994. This was done through the use of joint particulate air pollution-temperature response surfaces and by stratifying the effect of particulate air pollution on mortality by temperature. Evidence that the effect of particulate air pollution on mortality may depend on temperature is found. However, the results were sensitive to the number of degrees of freedom used in the confounder adjustments, the particulate air pollution exposure measure, and how the effects of temperature on mortality are modeled. The results were less sensitive to the estimation method used--generalized linear models and natural cubic splines or generalized additive models and smoothing splines. The results of this study suggest that in community particulate air pollution mortality time series studies the possibility of an interaction between daily particulate air pollution and daily mean temperature should be considered

  10. Comparison of personal air samplers and static air samplers

    International Nuclear Information System (INIS)

    Carter, M.W.; Lumsden, B.

    1979-01-01

    The authors demonstrate that radioactive air contamination levels calculated from PAS results will always be higher than air contamination levels calculated from SAS results, other conditions being equal. The most probable explanation seems to be in a relationship between the sampling velocity and the particle size of the dust sampled

  11. Desalinasi Air Laut Berbasis Energi Surya Sebagai Alternatif Penyediaan Air Bersih

    Directory of Open Access Journals (Sweden)

    I Gede Yogi Dewantara

    2018-03-01

    Full Text Available Penelitian ini berkonsentrasi pada kemampuan alat desalinasi tipe solar still dalam menyerap energi kalor matahari dan penggunaannya dalam proses kondensasi guna memproduksi air tawar untuk keperluan masyarakat. Alat desalinasi ini terdiri dari kotak distiller dengan plat absorber dan kain yang terdapat di dalamnya, serta kaca sebagai pentransmisian. Sistem kerja berawal dari air diteteskan melalui pipa dan jatuh pada kain yang akan menyerap air. Radiasi matahari akan memanaskan plat absober melalui kaca kemudian panas plat memanaskan air pada kain hingga menjadi uap dan menempel pada permukaan dalam kaca hingga terkonsensasi menjadi air suling. Pengukuran volume minimal dan maksimal alat sebesar 5 lt dan 7 lt dilakukan selama 4 hari. Melalui penelitian ini dapat disimpulkan bahwa intensitas matahari telah ada saat cahaya matahari mulai terlihat pada pukul 6 pagi dan difusi energi kalor matahari telah mulai dimanfaatkan pada waktu tersebut. Akan tetapi kinerja alat desalinasi masih sangat rendah, hal ini terlihat dari angka efisiensi yang hanya mencapai 4,45%.

  12. Perception of cabin air quality in airline crew related to air humidification, on intercontinental flights.

    Science.gov (United States)

    Lindgren, T; Norbäck, D; Wieslander, G

    2007-06-01

    The influence of air humidification in aircraft, on perception of cabin air quality among airline crew (N = 71) was investigated. In-flight investigations were performed in the forward part and in the aft part on eight intercontinental flights with one Boeing 767 individually, equipped with an evaporation humidifier combined with a dehumidifying unit, to reduce accumulation of condensed water in the wall construction. Four flights had the air humidification active when going out, and turned off on the return flight. The four others had the inverse humidification sequence. The sequences were randomized, and double blind. Air humidification increased relative air humidity (RH) by 10% in forward part, and by 3% in aft part of the cabin and in the cockpit. When the humidification device was active, the cabin air was perceived as being less dry (P = 0.008), and fresher (P = 0.002). The mean concentration of viable bacteria (77-108 cfu/m(3)), viable molds (74-84 cfu/m(3)), and respirable particles (1-8 microg/m3) was low, both during humidified and non-humidified flights. On flights with air humidification, there were less particles in the forward part of the aircraft (P = 0.01). In conclusion, RH can be slightly increased by using ceramic evaporation humidifier, without any measurable increase of microorganisms in cabin air. The cabin air quality was perceived as being better with air humidification. PRACTICAL IMPLICATION: Relative air humidity is low (10-20%) during intercontinental flights, and can be increased by using ceramic evaporation humidifier, without any measurable increase of microorganism in cabin air. Air humidification could increase the sensation of better cabin air quality.

  13. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  14. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  15. Baltimore Air Toxics Study (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, D.A. [Sullivan Environmental Consulting, Inc., Alexandria, VA (United States)

    1996-12-31

    The Baltimore Air Toxics Study is one of the three urban air toxics initiatives funded by EPA to support the development of the national air toxics strategy. As part of this project, the Air Quality Integrated Management System (AIMS) is under development. AIMS is designed to bring together the key components of urban air quality management into an integrated system, including emissions assessment, air quality modeling, and air quality monitoring. Urban area source emissions are computed for a wide range of pollutants and source categories, and are joined with existing point source emissions data. Measured air quality data are used to evaluate the adequacy of the emissions data and model treatments as a function of season, meteorological parameters, and daytime/nighttime conditions. Based on tested model performance, AIMS provides the potential to improve the ability to predict air quality benefits of alternative control options for criteria and toxic air pollutants. This paper describes the methods used to develop AIMS, and provides examples from its application in the Baltimore metropolitan area. The use of AIMS in the future to enhance environmental management of major industrial facilities also will be addressed in the paper.

  16. The role of open-air inhalatoria in the air quality improvement in spa towns.

    Science.gov (United States)

    Burkowska-But, Aleksandra; Kalwasińska, Agnieszka; Brzezinska, Maria Swiontek

    2014-08-01

    The present study was aimed at evaluating microbiological contamination of air in Ciechocinek and Inowrocław - Polish lowland spa towns. Additionally, the impact of open-air inhalatoria on the quality of air was evaluated. Air samples were collected seasonally in the urban areas, in the recreation areas and in the vicinity of inhalatoria in both towns using impaction. The numbers of mesophilic bacteria, staphylococci, hemolytic bacteria and actinomycetes were determined on media according to the Polish Standard PN-86/Z-04111/02. The number of moulds was determined on media according to the Polish Standard PN-86/Z-04111/03. While the highest numbers of microorganisms were noted at the sites located in the urban areas, the lowest numbers were noted in the vicinity of the open-air inhalatoria. In all the investigated air samples the values of bioaerosol concentrations were below the recommended TLVs (≤ 5000 CFU×m(-3) for both bacteria and fungi in outdoor environments). Location of the sampling site was invariably a decisive factor in determining the number of microorganisms in the air. The aerosol which is formed in the open-air inhalatoria has a positive influence on microbiological air quality. Owing to a unique microclimate and low air contamination, Ciechocinek and Inowrocław comply with all necessary requirements set for health resorts specializing in treating upper respiratory tract infections.

  17. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  18. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  19. Liberalisation of air cargo transport

    Science.gov (United States)

    2002-05-02

    Over a period of many years, international air cargo demand has continued to increase more rapidly than international air passenger demand. Air cargo arrangements need to be as efficient and expeditious as possible, to meet user requirements for air ...

  20. Infants Can Study Air Science.

    Science.gov (United States)

    Ward, Alan

    1983-01-01

    Provided are activities and demonstrations which can be used to teach infants about the nature of air, uses of air, and objects that fly in the air. The latter include airships, hot-air balloons, kites, parachutes, airplanes, and Hovercraft. (JN)

  1. RASDAQ: The final curtain

    OpenAIRE

    Cornelia POP; Cristina BALINT; Maria-Andrada GEORGESCU; Ioan Alin NISTOR

    2016-01-01

    The present paper continues the studies of Pop et al. (2014) and Pop et al. (2015) and completes the previous studies by presenting a brief survey of RASDAQ’s entire active life, the profile of RASDAQ indices, and focusing on the last 911 RASDAQ listed companies: their profile and their decision to be transferred on other market segments or to be delisted. The results of the present study confirms, from another viewpoint, the findings of Pop et al. (2014) and Pop et al. (2015):...

  2. Axisymmetric annular curtain stability

    International Nuclear Information System (INIS)

    Ahmed, Zahir U; Khayat, Roger E; Maissa, Philippe; Mathis, Christian

    2012-01-01

    A temporal stability analysis was carried out to investigate the stability of an axially moving viscous annular liquid jet subject to axisymmetric disturbances in surrounding co-flowing viscous gas media. We investigated in this study the effects of inertia, surface tension, the gas-to-liquid density ratio, the inner-to-outer radius ratio and the gas-to-liquid viscosity ratio on the stability of the jet. With an increase in inertia, the growth rate of the unstable disturbances is found to increase. The dominant (or most unstable) wavenumber decreases with increasing Reynolds number for larger values of the gas-to-liquid viscosity ratio. However, an opposite tendency for the most unstable wavenumber is predicted for small viscosity ratio in the same inertia range. The surrounding gas density, in the presence of viscosity, always reduces the growth rate, hence stabilizing the flow. There exists a critical value of the density ratio above which the flow becomes stable for very small viscosity ratio, whereas for large viscosity ratio, no stable flow appears in the same range of the density ratio. The curvature has a significant destabilizing effect on the thin annular jet, whereas for a relatively thick jet, the maximum growth rate decreases as the inner radius increases, irrespective of the surrounding gas viscosity. The degree of instability increases with Weber number for a relatively large viscosity ratio. In contrast, for small viscosity ratio, the growth rate exhibits a dramatic dependence on the surface tension. There is a small Weber number range, which depends on the viscosity ratio, where the flow is stable. The viscosity ratio always stabilizes the flow. However, the dominant wavenumber increases with increasing viscosity ratio. The range of unstable wavenumbers is affected only by the curvature effect. (paper)

  3. Perforating the Iron Curtain

    DEFF Research Database (Denmark)

    This collection, based upon contributions to the "Copenhagen Cold War Conference 2007", provides a detailed analysis of important aspects of the European détente process between East and West, as it is reflected in the most recent archival based research. It suggests that this process was far mor...

  4. APEX (Air Pollution Exercise) Volume 21: Legal References: Air Pollution Control Regulations.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Office of Manpower Development.

    The Legal References: Air Pollution Control Regulations Manual is the last in a set of 21 manuals (AA 001 009-001 029) used in APEX (Air Pollution Exercise), a computerized college and professional level "real world" game simulation of a community with urban and rural problems, industrial activities, and air pollution difficulties. The manual…

  5. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  6. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  7. Energy and air quality

    International Nuclear Information System (INIS)

    1981-12-01

    This is one of a series of handbooks designed to provide nontechnical readers with a general understanding of the interaction between energy development and environmental media and to provide a rudimentary data base from which estimates of potential future impacts can be made. This handbook describes the air quality impacts of energy development and summarizes the major federal legislation which regulates the potential air quality impacts of energy facilities and can thus influence the locations and timing of energy development. In addition, this report describes and presents the data which can be used as the basis for measurement, and in some cases, prediction of the potential conflicts between energy development and achieving and maintaining clean air. Energy utilization is the largest emission source of man-made air pollutants. Choices in energy resource development and utilization generate varying emissions or discharges into the atmosphere, the emissions are affected by the assimilative character of the atmosphere, and the resultant air pollutant concentrations have biological and aesthetic effects. This handbook describes the interrelationships of energy-related air emissions under various methods of pollution control, the assimilative character of the air medium, and the effects of air pollution. The media book is divided into three major sections: topics of concern relating to the media and energy development, descriptions of how to use available data to quantify and examine energy/environmental impacts, and the data

  8. Air Layer Drag Reduction

    Science.gov (United States)

    Ceccio, Steven; Elbing, Brian; Winkel, Eric; Dowling, David; Perlin, Marc

    2008-11-01

    A set of experiments have been conducted at the US Navy's Large Cavitation Channel to investigate skin-friction drag reduction with the injection of air into a high Reynolds number turbulent boundary layer. Testing was performed on a 12.9 m long flat-plate test model with the surface hydraulically smooth and fully rough at downstream-distance-based Reynolds numbers to 220 million and at speeds to 20 m/s. Local skin-friction, near-wall bulk void fraction, and near-wall bubble imaging were monitored along the length of the model. The instrument suite was used to access the requirements necessary to achieve air layer drag reduction (ALDR). Injection of air over a wide range of air fluxes showed that three drag reduction regimes exist when injecting air; (1) bubble drag reduction that has poor downstream persistence, (2) a transitional regime with a steep rise in drag reduction, and (3) ALDR regime where the drag reduction plateaus at 90% ± 10% over the entire model length with large void fractions in the near-wall region. These investigations revealed several requirements for ALDR including; sufficient volumetric air fluxes that increase approximately with the square of the free-stream speed, slightly higher air fluxes are needed when the surface tension is reduced, higher air fluxes are required for rough surfaces, and the formation of ALDR is sensitive to the inlet condition.

  9. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  10. Low cost solar air heater

    International Nuclear Information System (INIS)

    Gill, R.S.; Singh, Sukhmeet; Singh, Parm Pal

    2012-01-01

    Highlights: ► Single glazed low cost solar air heater is more efficient during summer while double glazed is better in winter. ► For the same initial investment, low cost solar air heaters collect more energy than packed bed solar air heater. ► During off season low cost solar air heater can be stored inside as it is light in weight. - Abstract: Two low cost solar air heaters viz. single glazed and double glazed were designed, fabricated and tested. Thermocole, ultraviolet stabilised plastic sheet, etc. were used for fabrication to reduce the fabrication cost. These were tested simultaneously at no load and with load both in summer and winter seasons along with packed bed solar air heater using iron chips for absorption of radiation. The initial costs of single glazed and double glazed are 22.8% and 26.8% of the initial cost of packed bed solar air heater of the same aperture area. It was found that on a given day at no load, the maximum stagnation temperatures of single glazed and double glazed solar air heater were 43.5 °C and 62.5 °C respectively. The efficiencies of single glazed, double glazed and packed bed solar air heaters corresponding to flow rate of 0.02 m 3 /s-m 2 were 30.29%, 45.05% and 71.68% respectively in winter season. The collector efficiency factor, heat removal factor based on air outlet temperature and air inlet temperature for three solar air heaters were also determined.

  11. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  12. Air-to-air heat pumps in real-life use

    DEFF Research Database (Denmark)

    Gram-Hanssen, Kirsten; Christensen, Toke Haunstrup; Petersen, Poul Erik

    2012-01-01

    This paper deals with individual air-to-air heat pumps in Danish dwellings and summerhouses and the question of to what extent they actually deliver savings of energy consumption. Results show that 20% of the expected reduction of electricity consumption is converted into increased comfort...... in the homes, including extended heating areas, keeping a higher temperature and a longer heating season and using the heat pump for air conditioning. Data include electricity consumption in 185 households before and after installation of heat pumps together with survey results of 480 households. Furthermore...... heating practices. These results have to be taken into account when making long-term energy planning for a sustainable energy system....

  13. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  14. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air......%. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion...... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  15. Mobile Air Monitoring Data Processing Strategies and Effects on Spatial Air Pollution Trends

    Science.gov (United States)

    The collection of real-time air quality measurements while in motion (i.e., mobile monitoring) is currently conducted worldwide to evaluate in situ emissions, local air quality trends, and air pollutant exposure. This measurement strategy pushes the limits of traditional data an...

  16. Exposure of Mammalian Cells to Air-Pollutant Mixtures at the Air-Liquid Interface

    Science.gov (United States)

    It has been widely accepted that exposure of mammalian cells to air-pollutant mixtures at the air-liquid interface is a more realistic approach than exposing cell under submerged conditions. The VITROCELL systems, are commercially available systems for air-liquid interface expo...

  17. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  18. 78 FR 63934 - Approval of Air Quality Implementation Plans; California; El Dorado County Air Quality Management...

    Science.gov (United States)

    2013-10-25

    ...] Approval of Air Quality Implementation Plans; California; El Dorado County Air Quality Management District... California for the El Dorado County Air Quality Management District (EDAQMD) portion of the California SIP... 24, 1987 Federal Register, May 25, 1988, U.S. EPA, Air Quality Management Division, Office of Air...

  19. AIRS/Aqua L2 Near Real Time (NRT) Cloud-Cleared Infrared Radiances (AIRS-only) V006 (AIRS2CCF_NRT) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Atmospheric Infrared Sounder (AIRS) Level 2 Near Real Time (NRT) Cloud-Cleared Infrared Radiances (AIRS-only) product (AIRS2CCF_NRT_006) differs from the routine...

  20. Solar air heaters and their applications

    Science.gov (United States)

    Selcuk, M. K.

    1977-01-01

    The solar air heater appears to be the most logical choice, as far as the ultimate application of heating air to maintain a comfortable environment is concerned. One disadvantage of solar air heaters is the need for handling larger volumes of air than liquids due to the low density of air as a working substance. Another disadvantage is the low thermal capacity of air. In cases where thermal storage is needed, water is superior to air. Design variations of solar air heaters are discussed along with the calculation of the efficiency of a flat plate solar air heater, the performance of various collector types, and the applications of solar air heaters. Attention is given to collectors with nonporous absorber plates, collectors with porous absorbers, the performance of flat plate collectors with finned absorbers, a wire mesh absorber, and an overlapped glass plate air heater.

  1. Air quality and disease

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Climate change is an important determinant of air quality. Climate change is an important determinant of air quality. Poor air quality associated with higher levels of respiratory and cardiovascular disease. Exposure to high levels of ground-level ozone associated with ...

  2. Air Force Leadership Diversity

    Science.gov (United States)

    2017-04-06

    served as a deputy maintenance group commander. Following Air War College he will take command of the 8th Maintenance Group, Kunsan Air Base, Korea ...discrimination in terms of 3 race, religion , sex, etc.: the demographics we have all heard about for years. Air Force Policy Directive (AFPD) 36

  3. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  4. Air Traffic Control Tools Assessment

    Directory of Open Access Journals (Sweden)

    Tomáš Noskievič

    2017-04-01

    Full Text Available Undoubtedly air transport in today’s world wouldn’t be able to exist without any air traffic control service. As the air transport has been coming through major changes and it has been expanding, it is assumed that its volume will be doubled in the next 15 years. Air traffic control uses strictly organised procedures to ensure safe course of air operations. With the skies covered with more airplanes every year, new tools must be introduced to allow the controllers to manage this rising amount of flying aircraft and to keep the air transport safe. This paper provides a comprehensive and organized material, which describes the newest tools and systems used by air traffic control officers. It proposes improvements for further research and development of ATC tools.

  5. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners

    International Nuclear Information System (INIS)

    Riffat, S.B.; Qiu Guoquan

    2004-01-01

    This paper compares the performance of three types of domestic air-conditioners, namely the vapour compression air-conditioner (VCAC), the absorption air-conditioner (AAC) and the thermoelectric air-conditioner (TEAC). The basic cycles of the three types of air-conditioning systems are described and methods to calculate their coefficients of performance are presented. General specification data for each type of air-conditioner are given, and performance characteristics are presented. The comparison shows that although VCACs have the advantages of high COP and low purchase price, use of these systems will be phased out due to their contribution to the greenhouse effect and depletion of the ozone layer. AACs are generally bulky, complex and expensive but operate on thermal energy, so their operational consumption is low. TEACs are environmental friendly, simple and reliable but still very expensive at present. Their low COP is an additional factor limiting their application for domestic cooling. TEACs however, have a large potential market as air-conditioners for small enclosures, such as cars and submarine cabins, where the power consumption would be low, or safety and reliability would be important

  6. Hiding in plain sight: Recognition and resistance in recent queer artists’ moving image

    OpenAIRE

    Guy, Laura

    2016-01-01

    In lieu of an abstract, here is the first paragraph of this article: Pauline Boudry and Renate Lorenz’s film Opaque (2014) opens with a monologue that establishes its speaker as a member of an unspecified underground faction. Concealed by a black curtain that hangs from a frame erected in the bluish depths of a disused swimming pool, at first all that we see of this fugitive is a vague outline. When the curtain is eventually pulled back, tugged slowly by a disembodied arm, it reveals another ...

  7. Evolution of fluid-like granular ejecta generated by sphere impact

    KAUST Repository

    Marston, Jeremy

    2012-05-01

    We present results from an experimental study of the speed and shape of the ejecta formed when a solid sphere impacts onto a granular bed. We use high-speed imaging at frame rates up to 100 000 f.p.s. to provide direct measurement of individual grain velocities and ejecta angles as well as the overall evolution of the granular ejecta. For larger grain sizes, the emergence velocities of the grains during the early stage flow, i.e. before the main ejecta curtain forms, increase with the kinetic energy of the impacting sphere but are inversely proportional to the time from impact. We also observe that the fastest grains, which can obtain velocities up to five times that of the impacting sphere (V g/V 0 = 5), generally emerge at the earliest times and with the lowest ejection angles. As the grain size is decreased, a more fluid-like behaviour is observed whereby the ejected material first emerges as a thin sheet of grains between the sphere and the bed surface, which is also seen when a sphere impacts a liquid pool. In this case, the sheet velocity is approximately double that of the impacting sphere (V s/V 0 = 2) and independent of the bulk packing fraction. For the finest grains we provide evidence of the existence of a vortex ring inside the ejecta curtain where grains following the air flow are entrained through the curtain. In contrast to predictions from previous studies, we find that the temporal evolution of the ejecta neck radius is not initially quadratic but rather approaches a square-root dependence on time, for the finest grains with the highest impact kinetic energy. The evolution therefore approaches that seen for the crown evolution in liquid drop impacts. By using both spherical glass beads and coarse sands, we show that the size and shape distribution are critical in determining the post-impact dynamics whereby the sands exhibit a qualitatively different response to impact, with grains ejected at lower speeds and at later times than for the glass

  8. Transportation and air quality

    International Nuclear Information System (INIS)

    Roseland, M.

    1992-01-01

    In the greater Vancouver regional district (GVRD), some 80% of the annual production of 600,000 tonnes of air pollutants come from motor vehicles. Three critical air quality issues in the GVRD are discussed: local air pollution, ozone layer depletion, and greenhouse gas emissions, all of which are fundamentally linked to transportation. Overall air quality in the GVRD has been judged acceptable by current federal standards, but ground-level ozone has exceeded maximum tolerable levels at some locations and concentrations of suspended particulates are above maximum acceptable levels. Serious deterioration in air quality has been predicted unless a concerted effort is made to manage air quality on an airshed-wide basis. The GVRD is developing Canada's first Air Management Plan with the goal of halving atmospheric emissions by 2000. GVRD transportation priorities stress public transit, walking, cycling, car pooling, and reducing of travel demand; however, the viability of such strategies depends on decisions made outside the transportation sector. Restricted authority and jurisdiction also hinder GVRD goals; the regional level of government has no authority over highways or transit and only has authority for pollution control in some parts of the Fraser Valley. Airshed quality management, using the Los Angeles example, is seen as a possible direction for future GVRD policymaking in the transportation sector. A single regional planning agency with responsibility for transportation, land use, and air quality management appears as the best option for an integrated approach to solve multiple problems. 19 refs

  9. Dioxin in Danish air

    Energy Technology Data Exchange (ETDEWEB)

    Vikelsoe, J.; Andersen, H.V. [National Environmental Research Inst., Roskilde (Denmark)

    2004-09-15

    To gain more knowledge about dioxin levels, sources and emissions in Denmark, the Danish government year 2001 initiated the Danish Dioxin Monitoring Program. The program is a series of investigations, comprising soil, compost, percolate, bio-ash, incineration of municipal and hazardous waste, deposition, air, lake and fjord sediment as well as cows milk and human milk. The present paper describes the preliminary results for the continued investigation of air. Deposition of dioxin over land or sea is of major importance for the human exposure, which takes place mainly from food intake. The dioxin are emitted mainly to the atmosphere, therefore air measurements are well suited for tracking the transport and fate of dioxin from sources to exposure. Whereas measurements from chimneys has been frequently used to estimate the industrial emission from point sources such as incinerators, air measurements also include emission from diffuse sources such as larger urban or industrial regions, residential quarters, and from evaporation. Furthermore, emission measurements must be done on known sources, whereas air measurements include contribution from unknown source. The major drawbacks of air measurements are the long duration required (years), and the results depends on meteorological conditions, such as temperature, rainfall, wind speed and direction. The purpose of the present study has been to measure dioxins in Danish air, emphasizing - background concentrations and annual variation - difference between urban, rural and residential zones - influence from local sources and long range transport - connection between dioxin in air and deposition.

  10. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Facilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  11. The Air University Pantheon of Air, Space, and Cyberspace Power Thinkers

    Science.gov (United States)

    2009-08-01

    Air Force would not have come as soon as it did. Learn more . . . • James J. Cooke, Billy Mitchell (Boulder, CO: L. Rienner, 2002). • Alfred F...Winter 1974): 18–25. • James Parton, “Air Force Spoken Here”: General Ira Eaker and the Command of the Air (Bethesda, MD: Adler and... Adler , 1986). 99 100 101 Dr. Theodore von Kármán (1881–1963) ♦ Father of supersonic flight ♦ Guggenheim Aeronautics Laboratory professor at the

  12. Our Nation's Air - annual air trends report, USA, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Annual air trends report in the form of an interactive web application. The report features a suite of visualization tools that allow the user to: -Learn about air...

  13. Air Pollution Training Programs.

    Science.gov (United States)

    Public Health Service (DHEW), Rockville, MD.

    This catalog lists the universities, both supported and not supported by the Division of Air Pollution, which offer graduate programs in the field of air pollution. The catalog briefly describes the programs and their entrance requirements, the requirements, qualifications and terms of special fellowships offered by the Division of Air Pollution.…

  14. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  15. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  16. Air quality in Europe - 2011 report

    Energy Technology Data Exchange (ETDEWEB)

    Guerreiro, C.; Larssen, S. (Norsk Inst. for Luftforskning (NILU), Lillestroem (Norway)); Leeuw, F. de (RIVM, Bilthoven (Netherlands)); Foltescu, V. (EEA, Copenhagen (Denmark))

    2011-11-15

    The annual report 'Air quality in Europe' summarises the most recent evaluation of Europe's air quality status. It is mainly based on air quality measurement data that have been made available officially by 32 EEA member countries as well as 6 EEA cooperating countries. The report includes maps and analyses of air quality status over the calendar year 2009. It also analyses air quality trends over the past years. The evaluation of the status and trends of air quality is based on ambient air measurements, in conjunction with reported anthropogenic emissions. The report summarizes the main effects of different air pollutants on human health, the environment and the climate. An overview of policies and measures at European level is also given for each pollutant. This report reviews progress towards meeting the requirements of the two air quality directives in force as well as the air quality guidelines set by the World Health Organization (WHO). The report is produced in support of European and national policy development and implementation in the field of air quality. It also supports air quality management and informs the general public on the current status and trends of air quality in Europe. (Author)

  17. Advanced air distribution

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2011-01-01

    The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...

  18. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  19. Natural Flow Air Cooled Photovoltaics

    Science.gov (United States)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  20. 49 CFR 570.57 - Air brake system and air-over-hydraulic brake subsystem.

    Science.gov (United States)

    2010-10-01

    ... the drain cocks in the service and supply reservoir on the truck or truck-tractor. Note the pressure.... Close the drain cocks, and, with the trailer(s) uncoupled, check air pressure buildup at the... brakes fully applied. (b) Air brake system hoses, tubes and connections. Air system tubes, hoses and...

  1. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  2. Air/Water Purification

    Science.gov (United States)

    1992-01-01

    After 18 years of research into air/water pollution at Stennis Space Center, Dr. B. C. Wolverton formed his own company, Wolverton Environmental Services, Inc., to provide technology and consultation in air and water treatment. Common houseplants are used to absorb potentially harmful materials from bathrooms and kitchens. The plants are fertilized, air is purified, and wastewater is converted to clean water. More than 100 U.S. communities have adopted Wolverton's earlier water hyacinth and artificial marsh applications. Catfish farmers are currently evaluating the artificial marsh technology as a purification system.

  3. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  4. Treatment of reverse osmosis (RO) concentrate by the combined Fe/Cu/air and Fenton process (1stFe/Cu/air-Fenton-2ndFe/Cu/air).

    Science.gov (United States)

    Ren, Yi; Yuan, Yue; Lai, Bo; Zhou, Yuexi; Wang, Juling

    2016-01-25

    To decompose or transform the toxic and refractory reverse osmosis (RO) concentrate and improve the biodegradability, 1stFe/Cu/air-Fenton-2ndFe/Cu/air were developed to treat RO concentrate obtained from an amino acid production plant in northern China. First, their operating conditions were optimized thoroughly. Furthermore, 5 control experiments were setup to confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and synergistic reaction between Fe/Cu/air and Fenton. The results suggest that the developed method could obtain high COD removal (65.1%) and BOD5/COD ratio (0.26) due to the synergistic reaction between Fe/Cu/air and Fenton. Under the optimal conditions, the influent and effluent of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and 5 control experiments were analyzed by using UV, FTIR, EEM and LC, which confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air. Therefore, the developed method in this study is a promising process for treatment of RO concentrate. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  6. Innovative application of air ejector as a pump for continuous air monitors

    International Nuclear Information System (INIS)

    Dhanasekaran, A.; Ajoy, K.C.; Santhanam, R.; Rajagopal, V.; Jose, M.T.

    2016-01-01

    Workplace monitoring, one of the key components of the radiation protection program is generally carried out by means of instruments installed permanently in respective areas or through portable air sampling instruments. Continuous air monitor (CAM) is one such monitor that constantly monitors the radionuclide concentration in air and triggers alarm as and when the air concentration goes above the pre-set levels. Conventional CAM system has a filter head, detector, display unit and a pump as four major parts. Pump may be either rotary vane or a vibrating diaphragm which are electrically driven using motors. Air lift pumps using ejectors are widely used where pump reliability and low maintenance are required, and where corrosive, abrasive, or radioactive fluids are handled. Since ejectors are uncomplicated alternative to vacuum pumps, an attempt was made to use the same as a pump for conventional CAMs. An ejector based sampling set up was made, tested and the results are represented in this paper

  7. Mobile Air Monitoring: Measuring Change in Air Quality in the City of Hamilton, 2005-2010

    Science.gov (United States)

    Adams, Matthew D.; DeLuca, Patrick F.; Corr, Denis; Kanaroglou, Pavlos S.

    2012-01-01

    This paper examines the change in air pollutant concentrations between 2005 and 2010 occurring in the City of Hamilton, Ontario, Canada. After analysis of stationary air pollutant concentration data, we analyze mobile air pollutant concentration data. Air pollutants included in the analysis are CO, PM[subscript 2.5], SO[subscript 2], NO,…

  8. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.

  9. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  10. Reduction of cooking oil fume exposure following an engineering intervention in Chinese restaurants.

    Science.gov (United States)

    Pan, Chih-Hong; Shih, Tung-Sheng; Chen, Chiou-Jong; Hsu, Jin-Huei; Wang, Shun-Chih; Huang, Chien-Ping; Kuo, Ching-Tang; Wu, Kuen-Yuh; Hu, Howard; Chan, Chang-Chuan

    2011-01-01

    A new engineering intervention measure, an embracing air curtain device (EACD), was used to increase the capture efficiency of cooker hoods and reduce cooking oil fume (COF) exposure in Chinese restaurants. An EACD was installed in six Chinese restaurants where the cooks complained of COF exposure. Before- and after-installation measurements were taken to compare changes in particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs) in kitchen air, and changes in levels of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) and malondialdehyde (MDA). The association between PM and PAHs in air and 8-OHdG and MDA in urine was evaluated by linear mixed-effects regression analysis. Results showed that geometric mean kitchen air levels of PM(10), PM(2.5), PM(1.0) and total particulate PAHs were significantly reduced after the EACDs were introduced. Urinary levels of 8-OHdG and MDA in cooks were also significantly lower after EACD instalment. PM(2.5), PM(1.0) and benzo(a)pyrene (BaP) levels were positively associated with urinary 8-OHdG levels after adjusting for key personal covariates. Urinary MDA levels in cooks were also positively associated with BaP levels after adjusting for key personal covariates. This study demonstrates that the EACD is effective for reducing COF and oxidative stress levels in cooks working in Chinese kitchens.

  11. 78 FR 53270 - Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality...

    Science.gov (United States)

    2013-08-29

    ... Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District... to the Sacramento Metropolitan Air Quality Management District (SMAQMD or District) portion of the..., Sacramento Metropolitan Air Quality Management District, Rule 214 (Federal New Source Review), Rule 203...

  12. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  13. Investigating air quality and air-related complaints in the City of Tshwane, South Africa

    CSIR Research Space (South Africa)

    Wright, C

    2011-12-01

    Full Text Available To determine the impact of implemented air quality interventions beyond ambient air pollution reductions, indicators need to be identified and appropriate health data need to be routinely collected to track air-related health. Presently, the only...

  14. Compressed air noise reductions from using advanced air gun nozzles in research and development environments.

    Science.gov (United States)

    Prieve, Kurt; Rice, Amanda; Raynor, Peter C

    2017-08-01

    The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.

  15. Study of compounds emitted during thermo-oxidative decomposition of polyester fabrics

    Directory of Open Access Journals (Sweden)

    Dzięcioł Małgorzata

    2016-03-01

    Full Text Available Compounds emitted during thermo-oxidative decomposition of three commercial polyester fabrics for indoor outfit and decorations (upholstery, curtains were studied. The experiments were carried out in a flow tubular furnace at 600°C in an air atmosphere. During decomposition process the complex mixtures of volatile and solid compounds were emitted. The main volatile products were carbon oxides, benzene, acetaldehyde, vinyl benzoate and acetophe-none. The emitted solid compounds consisted mainly of aromatic carboxylic acids and its derivatives, among which the greatest part took terephthalic acid, monovinyl terephthalate and benzoic acid. The small amounts of polycyclic aromatic hydrocarbons were also emitted. The emission profiles of the tested polyester fabrics were similar. The presence of toxic compounds indicates the possibility of serious hazard for people during fire.

  16. 22 CFR 228.22 - Air transportation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Air transportation. 228.22 Section 228.22... for USAID Financing § 228.22 Air transportation. (a) The eligibility of air transportation is... U.S. flag air carriers for all international air travel and transportation, unless such service is...

  17. Agriculture: Agriculture and Air Quality

    Science.gov (United States)

    Information on air emissions from agricultural practices, types of agricultural burning, air programs that may apply to agriculture, reporting requirements, and links to state and other federal air-quality information.

  18. Filtered air plastic chamber as an experimental facility to prove visible damage of crops due to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Y; Yoda, H; Omichi, S; Shiratori, K

    1975-01-01

    An experimental filtered air chamber was constructed to prove the visible damage of crops due to air pollution. The chamber was provided with another room into which non-filtered ambient air was introduced. The purified air was prepared by filtering ambient air with activated carbon. The average content of air pollutants in the purified air chamber was less than 10 to 20% of the ozone and 20% of the sulfur oxides in the ambient air. However, cultivated vegetables such as tobacco and spinach, which are susceptible to oxidant, showed no visible damage in the filtered air chamber, and showed the same damage in the nonfiltered air chamber as was seen in fields at the same time.

  19. Air void structure and frost resistance

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange

    2014-01-01

    ). This observation is interesting as the parameter of total surface area of air voids normally is not included in air void analysis. The following reason for the finding is suggested: In the air voids conditions are favourable for ice nucleation. When a capillary pore is connected to an air void, ice formation...... on that capillary pores are connected to air voids. The chance that a capillary pore is connected to an air void depends on the total surface area of air voids in the system, not the spacing factor.......This article compiles results from 4 independent laboratory studies. In each study, the same type of concrete is tested at least 10 times, the air void structure being the only variable. For each concrete mix both air void analysis of the hardened concrete and a salt frost scaling test...

  20. Air pollution - health and management

    Energy Technology Data Exchange (ETDEWEB)

    Klug, W; Runca, E; Suess, M J [eds.

    1984-01-01

    The proceedings of a joint workshop of the World Health Organization and the International Institute for Applied Systems Analysis are presented. The workshop was to review the interaction between man's industrial and urban activities and the environment, and the relationship between ambient air quality and human health, and to examine the effectiveness of proper management on the control and abatement of air pollution. The discussion topics included atmospheric processes and respective modelling, air pollution impact on human health, effects of air pollutants on aquatic and terrestrial ecosystems, air pollution episode cycles and management of control. A selected list of 11ASA and WHO/EURO publications related to air pollution is included. Separate abstracts were prepared for 15 papers in this book.

  1. Prototype Pompa Air Portable Tenaga Surya

    OpenAIRE

    Taufik, Mohammad

    2016-01-01

    Makalah ini menyajikan purwarupa pompa air portable tenaga surya. Sistem pompa air portable terdiri atas pompa air, panel surya, solar charge controller, battery, solar frame, tiang, dan box. Sistem dapat dirangkai, sehingga bersifat portable. Pompa air portable ini berguna untuk kolam, irigasi, dan penyediaan air bersih. Hasil optimasi memberikan spesifikasi pompa air berdaya 50 Watt dan tegangan 12 VDC, solar panel berdaya 50 Wp, battery berkapasitas 50 Ah dan tegangan 12 VDC, da...

  2. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  3. Dust-control for thick-seam wall mines.

    CSIR Research Space (South Africa)

    Belle, BK

    2002-02-01

    Full Text Available configuration and the belt curtains on the shearer. 3. Install, and evaluate the efficiency of, the physical shield curtains (conveyor belt or other flexible material) hanging from the shield structure inside the shield leg area at every 4th shield to reduce... and 1997, coal production hovered around the 50 million tonnes-a-year level (UK DTI, 2001). Currently, there are 16 producing underground mines in the UK, which includes 15 longwall faces, face lengths range from 250 m to 300 m (Creedy, 2001). Most...

  4. Clean air in the Anthropocene.

    Science.gov (United States)

    Lelieveld, Jos

    2017-08-24

    In atmospheric chemistry, interactions between air pollution, the biosphere and human health, often through reaction mixtures from both natural and anthropogenic sources, are of growing interest. Massive pollution emissions in the Anthropocene have transformed atmospheric composition to the extent that biogeochemical cycles, air quality and climate have changed globally and partly profoundly. It is estimated that mortality attributable to outdoor air pollution amounts to 4.33 million individuals per year, associated with 123 million years of life lost. Worldwide, air pollution is the major environmental risk factor to human health, and strict air quality standards have the potential to strongly reduce morbidity and mortality. Preserving clean air should be considered a human right, and is fundamental to many sustainable development goals of the United Nations, such as good health, climate action, sustainable cities, clean energy, and protecting life on land and in the water. It would be appropriate to adopt "clean air" as a sustainable development goal.

  5. Air quality and passenger comfort in an air-conditioned bus micro-environment.

    Science.gov (United States)

    Zhu, Xiaoxuan; Lei, Li; Wang, Xingshen; Zhang, Yinghui

    2018-04-12

    In this study, passenger comfort and the air pollution status of the micro-environmental conditions in an air-conditioned bus were investigated through questionnaires, field measurements, and a numerical simulation. As a subjective analysis, passengers' perceptions of indoor environmental quality and comfort levels were determined from questionnaires. As an objective analysis, a numerical simulation was conducted using a discrete phase model to determine the diffusion and distribution of pollutants, including particulate matter with a diameter air quality and dissatisfactory thermal comfort conditions in Jinan's air-conditioned bus system. To solve these problems, three scenarios (schemes A, B, C) were designed to alter the ventilation parameters. According to the results of an improved simulation of these scenarios, reducing or adding air outputs would shorten the time taken to reach steady-state conditions and weaken the airflow or lower the temperature in the cabin. The airflow pathway was closely related to the layout of the air conditioning. Scheme B lowered the temperature by 0.4 K and reduced the airflow by 0.01 m/s, while scheme C reduced the volume concentration of PM 10 to 150 μg/m 3 . Changing the air supply angle could further improve the airflow and reduce the concentration of PM 10 . With regard to the perception of airflow and thermal comfort, the scheme with an airflow provided by a 60° nozzle was considered better, and the concentration of PM 10 was reduced to 130 μg/m 3 .

  6. 78 FR 10589 - Revision of Air Quality Implementation Plan; California; Sacramento Metropolitan Air Quality...

    Science.gov (United States)

    2013-02-14

    ... Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District... Sacramento Metropolitan Air Quality Management District (SMAQMD or District) portion of the California State... sources within the areas covered by the plan as necessary to assure that the National Ambient Air Quality...

  7. Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as...

  8. Multifunction Lidar for Air Data and Kinetic Air Hazard Measurement, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ophir proposes to develop a multifunction, low-cost lidar capable of accurately measuring kinetic air hazards, and air data, simultaneously. The innovation is...

  9. 75 FR 65572 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2010-10-26

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY... Ohio Administrative Code (OAC) relating to the consolidation of Ohio's Ambient Air Quality Standards... apply to Ohio's SIP. Incorporating the air quality standards into Ohio's SIP helps assure that...

  10. Study of containment air cooler capacity in steam air environment during accident conditions

    International Nuclear Information System (INIS)

    Kansal, M.; Mohan, N.; Bhawal, R.N.; Bajaj, S.S.

    2002-01-01

    Full text: The air coolers are provided for controlling the temperature in the reactor building during normal operation. These air coolers also serve as the main heat sink for the removal of energy from high enthalpy air-steam mixture expected in reactor building under accident conditions. A subroutine COOLER has been developed to estimate the heat removal rate of the air coolers at high temperature and steam conditions. The subroutine COOLER has been attached with the code PACSR (post accident containment system response) used for containment pressure temperature calculation. The subroutine was validated using design parameters at normal operating condition. A study was done to estimate the heat removal rate for some postulated accident conditions. The study reveals that, under accident conditions, the heat removal rate of air coolers increases several times compared with normal operating conditions

  11. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile terminals mounted...... in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling-mounted diffuser...

  12. Process and apparatus for decontaminating air

    International Nuclear Information System (INIS)

    Reynolds, W.D.

    1993-01-01

    An apparatus for irradiating a contaminated air stream emanating from contaminated sources which contain mixtures of one or more volatile toxic and hazardous organic solvents or petroleum product vapors with ultraviolet wave energy below 200 nm is described comprising: a first means for passing the contaminated air stream via a tube into an enclosed empty air flow duct to allow free flow of said contaminated air stream; a second means for introducing a secondary fresh air stream into an inlet of said first means to dilute and maintain the contaminated air stream at a predetermined concentration level; a means for measuring a flow rate of said contaminated air stream; said air duct containing at least a first and second residence chambers separated by a wall divider; said divider containing at least one opening in which is mounted at least one centrally located ultraviolet wave energy source extending into said air stream to allow said contaminated air stream to pass around and in close contact with said wave energy source, wherein said contaminated air stream is irradiated by said wave energy source; an analyzer means for conducting on-line real time analysis of said diluted contaminated air stream in said first residence chamber, said analyzer means being capable of analyzing any residual contaminated mixtures in an effluent air stream from said second residence chamber; whereby said ultraviolet wave energy source functions to generate oxygen atom free radicals, other free radicals, ions, and ozone to react with the contaminated air strewn to produce unwanted acid gases, and wherein said effluent air stream containing the unwanted acid gases, being passed from said second residence chamber, can be disposed of in any manner known to the art

  13. New calculation method for thermodynamic properties of humid air in humid air turbine cycle – The general model and solutions for saturated humid air

    International Nuclear Information System (INIS)

    Wang, Zidong; Chen, Hanping; Weng, Shilie

    2013-01-01

    The article proposes a new calculation method for thermodynamic properties (i.e. specific enthalpy, specific entropy and specific volume) of humid air in humid air turbine cycle. The research pressure range is from 0.1 MPa to 5 MPa. The fundamental behaviors of dry air and water vapor in saturated humid air are explored in depth. The new model proposes and verifies the relationship between total gas mixture pressure and gas component pressures. This provides a good explanation of the fundamental behaviors of gas components in gas mixture from a new perspective. Another discovery is that the water vapor component pressure of saturated humid air equals P S , always smaller than its partial pressure (f·P S ) which was believed in the past researches. In the new model, “Local Gas Constant” describes the interaction between similar molecules. “Improvement Factor” is proposed for the first time by this article, and it quantitatively describes the magnitude of interaction between dissimilar molecules. They are combined to fully describe the real thermodynamic properties of humid air. The average error of Revised Dalton's Method is within 0.1% compared to experimentally-based data. - Highlights: • Our new model is suitable to calculate thermodynamic properties of humid air in HAT cycle. • Fundamental behaviors of dry air and water vapor in saturated humid air are explored in depth. • Local-Gas-Constant describes existing alone component and Improvement Factor describes interaction between different components. • The new model proposes and verifies the relationship between total gas mixture pressure and component pressures. • It solves saturated humid air thoroughly and deviates from experimental data less than 0.1%

  14. The user's influence on air change

    International Nuclear Information System (INIS)

    Kvisgaard, B.; Collet, P.F.

    1990-01-01

    Of the various parameters deciding the air change in a building, the influence of wind and the stack effect have in particular been focused on. Concurrently, with the increase in quality of buildings and the tightening of existing buildings, the influence of the climatic parameters is reduced, and other parameters gain a greater influence on the air change. One of the parameters having a great influence on the air change in tight buildings are the users. The air change rate is greatly influenced by the users not only in naturally ventilated buildings, but also in mechanically ventilated buildings. On the basis of continuous measurement of the air change in 28 dwellings, the proportion between the total air change (air change in house with occupants) and the basic air change (air change in a sealed house) is discussed. The air change in each of the dwellings has been measured for a period of about one week during occupancy. The measuring principle applied is the method with constant concentration of tracer gas

  15. Impacts of Lowered Urban Air Temperatures on Precursor Emission and Ozone Air Quality.

    Science.gov (United States)

    Taha, Haider; Konopacki, Steven; Akbari, Hashem

    1998-09-01

    Meteorological, photochemical, building-energy, and power plant simulations were performed to assess the possible precursor emission and ozone air quality impacts of decreased air temperatures that could result from implementing the "cool communities" concept in California's South Coast Air Basin (SoCAB). Two pathways are considered. In the direct pathway, a reduction in cooling energy use translates into reduced demand for generation capacity and, thus, reduced precursor emissions from electric utility power plants. In the indirect pathway, reduced air temperatures can slow the atmospheric production of ozone as well as precursor emission from anthropogenic and biogenic sources. The simulations suggest small impacts on emissions following implementation of cool communities in the SoCAB. In summer, for example, there can be reductions of up to 3% in NO x emissions from in-basin power plants. The photochemical simulations suggest that the air quality impacts of these direct emission reductions are small. However, the indirect atmospheric effects of cool communities can be significant. For example, ozone peak concentrations can decrease by up to 11% in summer and population-weighted exceedance exposure to ozone above the California and National Ambient Air Quality Standards can decrease by up to 11 and 17%, respectively. The modeling suggests that if these strategies are combined with others, such as mobile-source emission control, the improvements in ozone air quality can be substantial.

  16. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, AJ; Weusten, BLAM; Timmer, R; Akkermans, LMA; Smout, AJPM

    Background: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  17. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, A. J.; Weusten, B. L. A. M.; Timmer, R.; Akkermans, L. M. A.; Smout, A. J. P. M.

    2005-01-01

    BACKGROUND: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  18. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  19. 77 FR 12524 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY... Indiana State Implementation Plan (SIP) for lead (Pb) under the Clean Air Act (CAA). This submittal incorporates the National Ambient Air Quality Standards (NAAQS) for Pb promulgated by EPA in 2008. DATES...

  20. 75 FR 65594 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2010-10-26

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards AGENCY... the Ohio Administrative Code (OAC) relating to the consolidation of Ohio's Ambient Air Quality Standards (AAQS) into Ohio's State Implementation Plan (SIP) under the Clean Air Act. On April 8, 2009, and...

  1. 76 FR 72097 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-11-22

    ... Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This rule establishes air quality designations for most areas in the United States for the 2008 lead (Pb) National Ambient Air Quality Standards...

  2. Pure air-plasma bullets propagating inside microcapillaries and in ambient air

    KAUST Repository

    Lacoste, Deanna; Bourdon, Anne; Kuribara, Koichi; Urabe, Keiichiro; Stauss, Sven; Terashima, Kazuo

    2014-01-01

    This paper reports on the characterization of air-plasma bullets in microcapillary tubes and in ambient air, obtained without the use of inert or noble gases. The bullets were produced by nanosecond repetitively pulsed discharges, applied in a dielectric barrier discharge configuration. The anode was a tungsten wire with a diameter of 50 μm, centered in the microcapillary, while the cathode was a silver ring, fixed on the outer surface of the fused silica tube. The effects of the applied voltage and the inner diameter of the microcapillary tube on the plasma behavior were investigated. Inside the tubes, while the topology of the bullets seems to be strongly dependent on the diameter, their velocity is only a function of the amplitude of the applied voltage. In ambient air, the propagation of air bullets with a velocity of about 1.25 ×105 m s-1 is observed.

  3. Pure air-plasma bullets propagating inside microcapillaries and in ambient air

    KAUST Repository

    Lacoste, Deanna

    2014-11-04

    This paper reports on the characterization of air-plasma bullets in microcapillary tubes and in ambient air, obtained without the use of inert or noble gases. The bullets were produced by nanosecond repetitively pulsed discharges, applied in a dielectric barrier discharge configuration. The anode was a tungsten wire with a diameter of 50 μm, centered in the microcapillary, while the cathode was a silver ring, fixed on the outer surface of the fused silica tube. The effects of the applied voltage and the inner diameter of the microcapillary tube on the plasma behavior were investigated. Inside the tubes, while the topology of the bullets seems to be strongly dependent on the diameter, their velocity is only a function of the amplitude of the applied voltage. In ambient air, the propagation of air bullets with a velocity of about 1.25 ×105 m s-1 is observed.

  4. Air pollutant and greenhouse gas emissions - 'Namea-Air' - February 2017

    International Nuclear Information System (INIS)

    Baude, Manuel

    2017-02-01

    For the first time, the SOeS (Monitoring and Statistics Directorate of France's Ministry of the Environment) is publishing air pollutant emissions accounts in the National Accounting Matrix Including Environmental Accounts (NAMEA) format for the years 1990, 1995, 2000, 2005, and 2008 to 2014. Namea-Air is an inventory format breaking down emissions of greenhouse gases (GHG) and air pollutants into 64 branches of economic activity and identifying a 'direct household emissions' category. (author)

  5. Compressed Air Production Using Vehicle Suspension

    OpenAIRE

    Ninad Arun Malpure; Sanket Nandlal Bhansali

    2015-01-01

    Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are co...

  6. Dynamic Performance of a Residential Air-to-Air Heat Pump.

    Science.gov (United States)

    Kelly, George E.; Bean, John

    This publication is a study of the dynamic performance of a 5-ton air-to-air heat pump in a residence in Washington, D.C. The effect of part-load operation on the heat pump's cooling and heating coefficients of performance was determined. Discrepancies between measured performance and manufacturer-supplied performance data were found when the unit…

  7. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  8. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  9. 78 FR 19990 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality...

    Science.gov (United States)

    2013-04-03

    ... Promulgation of Air Quality Implementation Plans; Ohio; Ohio Ambient Air Quality Standards; Correction AGENCY... approved revisions to Ohio regulations that consolidated air quality standards in a new chapter of rules... State's air quality standards into Ohio Administrative Code (OAC) 3745-25 and modifying an assortment of...

  10. 77 FR 12482 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY... incorporates the National Ambient Air Quality Standards (NAAQS) for Pb promulgated by EPA in 2008. DATES: This... FR 66964) and codified at 40 CFR 50.16, ``National primary and secondary ambient air quality...

  11. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  12. Air Quality Guide for Ozone

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Air Quality Guide for Ozone Ground-level ozone is one of our nation’s most common air pollutants. Use the chart below to help reduce ...

  13. Lean in Air Permitting Guide

    Science.gov (United States)

    The Lean in Air Permitting Guide is designed to help air program managers at public agencies better understand the potential value and results that can be achieved by applying Lean improvement methods to air permitting processes.

  14. A directional passive air sampler for monitoring polycyclic aromatic hydrocarbons (PAHs) in air mass

    International Nuclear Information System (INIS)

    Tao, S.; Liu, Y.N.; Lang, C.; Wang, W.T.; Yuan, H.S.; Zhang, D.Y.; Qiu, W.X.; Liu, J.M.; Liu, Z.G.; Liu, S.Z.; Yi, R.; Ji, M.; Liu, X.X.

    2008-01-01

    A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test. - A novel directional passive air sampler was developed and tested for monitoring PAHs in air masses from different directions

  15. Air Quality Assessment Using Interpolation Technique

    Directory of Open Access Journals (Sweden)

    Awkash Kumar

    2016-07-01

    Full Text Available Air pollution is increasing rapidly in almost all cities around the world due to increase in population. Mumbai city in India is one of the mega cities where air quality is deteriorating at a very rapid rate. Air quality monitoring stations have been installed in the city to regulate air pollution control strategies to reduce the air pollution level. In this paper, air quality assessment has been carried out over the sample region using interpolation techniques. The technique Inverse Distance Weighting (IDW of Geographical Information System (GIS has been used to perform interpolation with the help of concentration data on air quality at three locations of Mumbai for the year 2008. The classification was done for the spatial and temporal variation in air quality levels for Mumbai region. The seasonal and annual variations of air quality levels for SO2, NOx and SPM (Suspended Particulate Matter have been focused in this study. Results show that SPM concentration always exceeded the permissible limit of National Ambient Air Quality Standard. Also, seasonal trends of pollutant SPM was low in monsoon due rain fall. The finding of this study will help to formulate control strategies for rational management of air pollution and can be used for many other regions.

  16. Joakim Helenius: Estonian Air võtku eeskuju airBalticust / Siim Sultson

    Index Scriptorium Estoniae

    Sultson, Siim

    2010-01-01

    Estonian Airi ühe võimaliku nõukogu esimehe Jaokim Heleniuse hinnangul on väikeste lennufirmade, nagu Estonian Air ja airBaltic jaoks päris palju tegutsemisruumi. Estonian Airil tuleb leida oma nišš ja kindel, kuid omanäoline strateegia

  17. Formation of free round jets with long laminar regions at large Reynolds numbers

    Science.gov (United States)

    Zayko, Julia; Teplovodskii, Sergey; Chicherina, Anastasia; Vedeneev, Vasily; Reshmin, Alexander

    2018-04-01

    The paper describes a new, simple method for the formation of free round jets with long laminar regions by a jet-forming device of ˜1.5 jet diameters in size. Submerged jets of 0.12 m diameter at Reynolds numbers of 2000-12 560 are experimentally studied. It is shown that for the optimal regime, the laminar region length reaches 5.5 diameters for Reynolds number ˜10 000 which is not achievable for other methods of laminar jet formation. To explain the existence of the optimal regime, a steady flow calculation in the forming unit and a stability analysis of outcoming jet velocity profiles are conducted. The shortening of the laminar regions, compared with the optimal regime, is explained by the higher incoming turbulence level for lower velocities and by the increase of perturbation growth rates for larger velocities. The initial laminar regions of free jets can be used for organising air curtains for the protection of objects in medicine and technologies by creating the air field with desired properties not mixed with ambient air. Free jets with long laminar regions can also be used for detailed studies of perturbation growth and transition to turbulence in round jets.

  18. The impact of draught related to air velocity, air temperature and workload.

    Science.gov (United States)

    Griefahn, B; Künemund, C; Gehring, U

    2001-08-01

    This experimental study was designed to test the hypotheses that the effects of draught increase with higher air velocity, with lower air temperature, and with lower workload. Thirty healthy young males were exposed to horizontal draught during 55 min while they operated an arm ergometer in a standing posture. Air velocity, air temperature, and workload were varied in 3 steps each, between 11 and 23 degrees C, 0.1 and 0.3 m/s, and 104 to 156 W/m2, respectively. The 27 combinations were distributed over subjects in a fractional factorial 3(3)-design. The participants were clothed for thermal neutrality. Workload was measured at the end of the sessions by respirometry. Draught-induced annoyance was determined every 5 min, separately for 10 body sites. Corresponding skin temperature was also recorded. The hypotheses were verified for the influence of air velocity and air temperature. Regarding workload, local heat production is probably decisive, meaning that draft-induced local annoyance is inversely related to workload in active but independent from workload in non-active body areas. To improve the situation for the workers concerned it is suggested to apply protective gloves that cover an as great area of the forearms as possible and to limit airflows to mean velocities of less than 0.2 m/s (with turbulence intensities of 50%).

  19. Perceived indoor air quality and its relationship to air pollutants in French dwellings.

    Science.gov (United States)

    Langer, S; Ramalho, O; Le Ponner, E; Derbez, M; Kirchner, S; Mandin, C

    2017-11-01

    Perception of indoor air quality (PIAQ) was evaluated in a nationwide survey of 567 French dwellings, and this survey was combined with measurements of gaseous and particulate matter (PM 10 and PM 2.5 ) indoor air pollutants and indoor climate parameters. The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors. Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. 77 FR 53779 - Reports by Air Carriers on Incidents Involving Animals During Air Transport

    Science.gov (United States)

    2012-09-04

    ... Involving Animals During Air Transport AGENCY: Office of the Secretary (OST), Department of Transportation... period of an NPRM on the reporting of incidents involving animals during air transport that was published... animal during air transport. The NPRM proposed to: (1) Expand the reporting requirement to U.S. carriers...

  1. Air Warfare

    Science.gov (United States)

    2002-03-01

    genus as its predecessor of pre-war days. It would, however, be erroneous to conclude from this that the military value of each new development was...the paucity of communications, its conduct, when acting alone, has of necessity to be somewhat stereotyped in nature, and to con- form to a pre...the air, the attack commander, provided his command be equipped with defensive air power, has a rôle to perform which is simple and stereotyped in

  2. Forced Air-Breathing PEMFC Stacks

    Directory of Open Access Journals (Sweden)

    K. S. Dhathathreyan

    2012-01-01

    Full Text Available Air-breathing fuel cells have a great potential as power sources for various electronic devices. They differ from conventional fuel cells in which the cells take up oxygen from ambient air by active or passive methods. The air flow occurs through the channels due to concentration and temperature gradient between the cell and the ambient conditions. However developing a stack is very difficult as the individual cell performance may not be uniform. In order to make such a system more realistic, an open-cathode forced air-breathing stacks were developed by making appropriate channel dimensions for the air flow for uniform performance in a stack. At CFCT-ARCI (Centre for Fuel Cell Technology-ARC International we have developed forced air-breathing fuel cell stacks with varying capacity ranging from 50 watts to 1500 watts. The performance of the stack was analysed based on the air flow, humidity, stability, and so forth, The major advantage of the system is the reduced number of bipolar plates and thereby reduction in volume and weight. However, the thermal management is a challenge due to the non-availability of sufficient air flow to remove the heat from the system during continuous operation. These results will be discussed in this paper.

  3. Air ions and aerosol science

    International Nuclear Information System (INIS)

    Tammet, H.

    1996-01-01

    Collaboration between Gas Discharge and Plasma Physics, Atmospheric Electricity, and Aerosol Science is a factor of success in the research of air ions. The concept of air ion as of any carrier of electrical current through the air is inherent to Atmospheric Electricity under which a considerable statistical information about the air ion mobility spectrum is collected. A new model of air ion size-mobility correlation has been developed proceeding from Aerosol Science and joining the methods of neighboring research fields. The predicted temperature variation of the mobility disagrees with the commonly used Langevin rule for the reduction of air ion mobilities to the standard conditions. Concurrent errors are too big to be neglected in applications. The critical diameter distinguishing cluster ions and charged aerosol particles has been estimated to be 1.4 endash 1.8 nm. copyright 1996 American Institute of Physics

  4. Air-breathing behavior and physiological responses to hypoxia and air exposure in the air-breathing loricariid fish, Pterygoplichthys anisitsi.

    Science.gov (United States)

    da Cruz, André Luis; da Silva, Hugo Ribeiro; Lundstedt, Lícia Maria; Schwantes, Arno Rudi; Moraes, Gilberto; Klein, Wilfried; Fernandes, Marisa Narciso

    2013-04-01

    Hypoxic water and episodic air exposure are potentially life-threatening conditions that fish in tropical regions can face during the dry season. This study investigated the air-breathing behavior, oxygen consumption, and respiratory responses of the air-breathing (AB) armored catfish Pterygoplichthys anisitsi. The hematological parameters and oxygen-binding characteristics of whole blood and stripped hemoglobin and the intermediate metabolism of selected tissue in normoxia, different hypoxic conditions, and after air exposure were also examined. In normoxia, this species exhibited high activity at night and AB behavior (2-5 AB h(-1)). The exposure to acute severe hypoxia elicited the AB behavior (4 AB h(-1)) during the day. Under progressive hypoxia without access to the water surface, the fish were oxyregulators with a critical O2 tension, calculated as the inspired water O2 pressure, as 47 ± 2 mmHg. At water O2 tensions lower than 40 mmHg, the fish exhibited continuous apnea behavior. The blood exhibited high capacity for transporting O2, having a cathodic hemoglobin component with a high Hb-O2 affinity. Under severe hypoxia, the fish used anaerobic metabolism to maintain metabolic rate. Air exposure revealed physiological and biochemical traits similar to those observed under normoxic conditions.

  5. Strategy Guideline: Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  6. Air Risk Information Support Center

    Energy Technology Data Exchange (ETDEWEB)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  7. Air Quality Management Process Cycle

    Science.gov (United States)

    Air quality management are activities a regulatory authority undertakes to protect human health and the environment from the harmful effects of air pollution. The process of managing air quality can be illustrated as a cycle of inter-related elements.

  8. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  9. Compressed Air Production Using Vehicle Suspension

    Directory of Open Access Journals (Sweden)

    Ninad Arun Malpure

    2015-08-01

    Full Text Available Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are collecting air in the cylinder and store this energy into the tank by simply driving the vehicle. This method is non-conventional as no fuel input is required and is least polluting.

  10. A Long-Life Lithium-Air Battery in Ambient Air with a Polymer Electrolyte Containing a Redox Mediator.

    Science.gov (United States)

    Guo, Ziyang; Li, Chao; Liu, Jingyuan; Wang, Yonggang; Xia, Yongyao

    2017-06-19

    Lithium-air batteries when operated in ambient air generally exhibit poor reversibility and cyclability, because of the Li passivation and Li 2 O 2 /LiOH/Li 2 CO 3 accumulation in the air electrode. Herein, we present a Li-air battery supported by a polymer electrolyte containing 0.05 m LiI, in which the polymer electrolyte efficiently alleviates the Li passivation induced by attacking air. Furthermore, it is demonstrated that I - /I 2 conversion in polymer electrolyte acts as a redox mediator that facilitates electrochemical decomposition of the discharge products during recharge process. As a result, the Li-air battery can be stably cycled 400 times in ambient air (relative humidity of 15 %), which is much better than previous reports. The achievement offers a hope to develop the Li-air battery that can be operated in ambient air. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  12. Infrequent air contamination with Acinetobacter baumannii of air surrounding known colonized or infected patients.

    Science.gov (United States)

    Rock, Clare; Harris, Anthony D; Johnson, J Kristie; Bischoff, Werner E; Thom, Kerri A

    2015-07-01

    Using a validated air sampling method we found Acinetobacter baumannii in the air surrounding only 1 of 12 patients known to be colonized or infected with A. baumannii. Patients' closed-circuit ventilator status, frequent air exchanges in patient rooms, and short sampling time may have contributed to this low burden.

  13. Air quality compliance improvements through operational management of air resources (OMAR)

    International Nuclear Information System (INIS)

    Goddard, W.B.; Goddard, C.B.

    1990-01-01

    Geothermal well fields and power plants require operational and emergency atmospheric venting. Venting activities are monitored for compliance with regulations which limit air pollutant emissions and Ambient Air Quality Standards (AAQS). Continuous compliance monitoring data which includes hydrogen sulfide (H2S) levels and meteorological conditions is only available moths after being compiled. In this paper an automated computerized system called OMAR is described in the following which checks data and allows users access to real-time and near real-time data reports. The data can then be used for managing necessary venting or other real-time data needs. The OMAR system hardware and software is descried and is in use at The Geysers and at the Coso KGRA geothermal developments in California. The system has been designed to assist developers, engineers, scientists, and the local air districts in their goal of maintaining ambient air quality within Federal, State and Local standards

  14. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  15. Ozone - Current Air Quality Index

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Current AQI Forecast AQI Loop More Maps AQI: Good (0 - 50) ... resources for Hawaii residents and visitors more announcements Air Quality Basics Air Quality Index | Ozone | Particle Pollution | Smoke ...

  16. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    Science.gov (United States)

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  17. Air compliance through pollution prevention at Air Force Materiel Command facilities.

    Energy Technology Data Exchange (ETDEWEB)

    Kolpa, R.; Ryckman, S.J. Jr.; Smith, A.E.

    1999-03-19

    Options for air compliance through pollution prevention (P2) have been identified at 14 facilities of the US Air Force Materiel Command, ranging from depots with significant light industrial activity to laboratories. Previous P2 efforts concentrated on reducing hazardous and solid wastes, with any reduction in air impacts generally being a collateral benefit. This work focused on reducing air emissions and air compliance vulnerabilities. P2 options were identified in three stages. First, potentially applicable P2 options were identified from Internet and published information. Attention was given to identifying the types of sources to which an option could be applied, the option's state of development, and constraints that could limit its application. Traditional P2 options involving technology or equipment changes and material substitution were considered. In addition, newer approaches based on administrative ''controls'' were considered. These included inserting P2 into operating permits in exchange for administrative relief, privatization, derating boilers, and reducing an installation's potential to emit and compliance vulnerability by separating sources not under the Air Force's ''common control.'' Next, criteria and toxic emissions inventories by source category were prepared from inventory data supplied by facilities. The major problems at this stage were differences in the levels of detail provided by facilities and in the categories used by different installations. Emitting categories were matched to P2 option categories to identify candidate options. Candidates were screened to account for local regulations and technical information about sources in the inventories. When possible, emission reductions were estimated to help facility personnel prioritize options. Some options identified are being actively pursued by facilities to determine their site-specific feasibility. Although much work has been

  18. Evaluation of AirGIS: a GIS-based air pollution and human exposure modelling system

    DEFF Research Database (Denmark)

    Ketzel, Matthias; Berkowicz, Ruwim; Hvidberg, Martin

    2011-01-01

    This study describes in brief the latest extensions of the Danish Geographic Information System (GIS)-based air pollution and human exposure modelling system (AirGIS), which has been developed in Denmark since 2001 and gives results of an evaluation with measured air pollution data. The system...... shows, in general, a good performance for both long-term averages (annual and monthly averages), short-term averages (hourly and daily) as well as when reproducing spatial variation in air pollution concentrations. Some shortcomings and future perspectives of the system are discussed too....

  19. The Assessment of Air Pollutant Concentrations and Air Quality Index in Shiraz during 2011-2013

    Directory of Open Access Journals (Sweden)

    Monireh Majlesi Nasr

    2016-06-01

    Full Text Available Background: Exposure to air pollutants can cause many problems, including the health effects in humans and animals. The aim of this study was to assay the air quality in the Shiraz city during 2011-2013. Methods: In this descriptive-analytical study, the air pollutant data during the study period were taken from Air Quality Co. for two main stations i.e. Darvazeh Kazeroun and Imam Hossein and then were analysed to determine air quality index. Results: The maximum (0.018 ppm and minimum (0.015 ppm annual concentration of SO2 were determined in 2011 and 2013, respectively. The maximum NO2 concentration was measured in summer 2011 with a value of 0.025 ppm. Regarding ozone, the highest average concentration was measured in the summer season of 2013 with the concentration of 0.068 ppm. In terms of air quality, the worst situation was experienced in 2011, which about 31 percent of the days have been marked as unhealthy, but during the last years of the study, the air quality get better. Conclusion: In general, the results of the study showed that SO2 concentration has been decreased during recent years due to strengthen of air pollution regulation but NO2 concentration was increased because the number of gas fuel automobile was also increased. With regard to air quality, it has an improving trend during the study period.

  20. Impacts of Changes of Indoor Air Pressure and Air Exchange Rate in Vapor Intrusion Scenarios.

    Science.gov (United States)

    Shen, Rui; Suuberg, Eric M

    2016-02-01

    There has, in recent years, been increasing interest in understanding the transport processes of relevance in vapor intrusion of volatile organic compounds (VOCs) into buildings on contaminated sites. These studies have included fate and transport modeling. Most such models have simplified the prediction of indoor air contaminant vapor concentrations by employing a steady state assumption, which often results in difficulties in reconciling these results with field measurements. This paper focuses on two major factors that may be subject to significant transients in vapor intrusion situations, including the indoor air pressure and the air exchange rate in the subject building. A three-dimensional finite element model was employed with consideration of daily and seasonal variations in these factors. From the results, the variations of indoor air pressure and air exchange rate are seen to contribute to significant variations in indoor air contaminant vapor concentrations. Depending upon the assumptions regarding the variations in these parameters, the results are only sometimes consistent with the reports of several orders of magnitude in indoor air concentration variations from field studies. The results point to the need to examine more carefully the interplay of these factors in order to quantitatively understand the variations in potential indoor air exposures.