WorldWideScience
 
 
1

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly ...

2009-02-01

2

Radiotherapy for nonfunctioning pituitary adenomas: from conventional to modern stereotactic radiation techniques  

British Library Electronic Table of Contents (United Kingdom)

The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...

2007-01-01

3

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV ...

2009-09-01

4

Repeat Stereotactic Radiosurgery for Acoustic Neuromas  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at ...

2010-02-01

5

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases  

International Nuclear Information System (INIS)

This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with ?4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10?20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a ...

2009-09-01

6

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic ...

2010-11-21

7

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

8

Radiotherapy for brain metastases from renal cell cancer. Should whole-brain radiotherapy be added to stereotactic radiosurgery? Analysis of 88 patients  

International Nuclear Information System (INIS)

Purpose: To evaluate the role of stereotactic radiosurgery (SRS) and whole-brain radiotherapy (WBRT) for the treatment of brain metastases in patients with renal cell cancer (RCC). Patients and methods: 88 patients were treated with either SRS (n = 51) or SRS + WBRT (n = 17) for one to three lesions, or with WBRT (n = 20) for more than three brain metastases. Overall survival (OS), intracerebral control (IC) and local control (LC) were retrospectively analyzed. Six potential prognostic factors were assessed: age, gender, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Results: The median times for OS, IC, and LC from the time of diagnosis were 11, 9, and 10 months. The median OS times for SRS, SRS + WBRT, and WBRT were 12, 16, and 2 months. Addition of WBRT to the SRS improved IC (p = 0.032) but not OS (p = 0.703). On multivariate analyses, ...

2010-04-01

9

Radiosurgery for metastatic brain tumors  

International Nuclear Information System (INIS)

Stereotactic radiosurgery (SRS) precisely delivers high-dose radiation to a small target (usually less than 3-4 cm in diameter), in a single session with steep dose-fall, employing various radiation methods. SRS provides good tumor control for small brain metastases from various primary cancers, with minimal untoward effects on surrounding normal brain. This excellent tumor control prevents neurological death and maintains good activity of daily life. Although surgery with whole-brain radiation therapy (WBRT) remains an important option for patients with a solitary brain metastasis, SRS with or without WBRT should be considered in patients with a limited number of small tumors and a good prognosis. Many reports, as well as both retrospective and prospective reviews, have shown WBRT before or after SRS to improve local control and reduce new distant lesion emergence. However, upfront WBRT does not improve survival. There are two major delivery ...

2009-08-01

10

Fractionated stereotactic radiotherapy in the treatment of pituitary macroadenomas  

UK PubMed Central (United Kingdom)

BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available

2008-12-01

11

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

14

Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose  

UK PubMed Central (United Kingdom)

PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available

15

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

16

Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

2005-01-01

17

Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report  

Energy Technology Data Exchange (ETDEWEB)

A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective ...

2001-08-01

18

Gamma Knife radiosurgery for vestibular schwannoma: case report and review of the literature  

UK PubMed Central (United Kingdom)

Vestibular schwannomas, also called acoustic neuromas, are benign tumors of the vestibulocochlear nerve. Patients with these tumours almost always present with signs of hearing loss, and many also experience...Full Text Available

19

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

20

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... 46 DOUGLAS BOCCUZZI, MS, DABR: There are some electromagnetic fields in the room, not strong. You can ... 5 weeks or is she feeling any side effects? 00:43:33 SUSAN Y. KIM, MD: She ...

 
 
 
 
21

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

22

Excessive Soft Tissue Reaction after Stereotactic Body Radiation Therapy in a Woman with Four Different Cancer Diagnoses  

UK PubMed Central (United Kingdom)

Patients experiencing several cancers can be a challenge, as optimal treatment options for the different cancers might interfere with each other. In this case report, we present a woman diagnosed with...Full Text Available

23

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

24

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...

2007-01-01

25

CyberKnife SRS: new technologies that enhance the treatment of cancer  

International Nuclear Information System (INIS)

The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision

2008-11-26

26

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors; Combined with hyperthermia  

Energy Technology Data Exchange (ETDEWEB)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation ...

1990-05-01

27

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors  

International Nuclear Information System (INIS)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation ...

1990-01-01

28

Dosimetric Evaluation of Heterogeneity Corrections for RTOG 0236: Stereotactic Body Radiation Therapy of Inoperable Stage I/II Non-Small Cell Lung Cancer  

UK PubMed Central (United Kingdom)

PurposeUsing a retrospective analysis of treatment plans submitted from multiple institutions accruing patients to the RTOG #0236 non-small cell SBRT protocol, this...Full Text Available

2009-03-15

29

Stereotactic body radiotherapy for unresectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A statistically significant association between ...

2010-01-01

30

Outcome of moderately dosed radiosurgery for limited brain metastases. Report of a single-center experience  

International Nuclear Information System (INIS)

Purpose: Efficacy and safety of the own single-center experience with moderately dosed radiosurgery (SRS) for limited (one to four) brain metastases were analyzed and correlated with patient- and treatment-related variables. Patients and Methods: Between 05/1998 and 10/2006, 93 patients received SRS for a total of 142 brain metastases. The median number of brain metastases treated per patient was one (range, one to four). 46 patients (49%) received initial SRS alone, 13 patients (14%) SRS with up-front whole-brain radiotherapy (WBRT), and 34 patients (37%) SRS for recurrent metastases after WBRT. Median dose was 16 Gy (range, 10-20 Gy). Results: Median overall survival (OS) was 7.5 months. The actuarial 6- and 12-month data for OS were 60% and 35%, for local brain control (LBC) 87% and 79%, and for distant brain control (DBC) 48% and 37%, respectively. Only ten of 46 patients (22%) with initial SRS alone ultimately received WBRT. Ten patients suffered from seizures ...

2010-02-01

31

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional variations were not ...

2007-06-01

32

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

33

(International Panel on 14 MeV Intense Neutron Source Based on Accelerators for Fusion Materials Study)  

Energy Technology Data Exchange (ETDEWEB)

Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.

1991-02-14

34

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors cisplatin containing ...

2001-09-01

35

Transmutations of nuclear waste. Progress report RAS programme 1995: Recycling and transmutation of actinides and fission products  

Energy Technology Data Exchange (ETDEWEB)

This report describes the progress of the Dutch RAS programme on `Recycling and Transmutation of Actinides and Fission Products` over the year 1995, which is the second year of the 4-year programme 1994-1997. An extensive listing of reports and publications from 1991 to 1995 is given. Highlights in 1995 were: -The completion of the European Strategy Study on Nuclear Waste Transmutation as a result of which the understanding of transmutation of plutonium, minor actinides and long-lived fission products in thermal and fast reactors has been increased significantly. Important ECN contributions were given on Am, {sup 99}Tc and {sup 129}I transmutation options. Follow-up contracts have been obtained for the study of 100% MOX cores and accelerator-based transmutation. - Important progress in the evaluation of CANDU reactors for burning very large amounts of transuranium mixtures in inert matrices. - The first RAS irradiation experiment in the HFR, in which the ...

1996-04-01

36

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...

1998-11-06

37

The compact linear collider CLIC  

CERN Document Server

A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A new test facility is being built at CERN for this purpose with the aim to demonstrate the key feasibility ...

2004-01-01

38

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...

39

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ionization chamber. The absorbed dose by BPL and ETAR, ...

2004-12-01

40

Preoperative MR-guided localization of suspicious breast lesions; MR-gesteuerte praeoperative Drahtmarkierung unklarer Mammalaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the lesion was 7.6{+-}2.6 mm (range 3-14 mm). Conclusion: Suspicious breast lesions detectable only in MR imaging can be accurately localized with a hook wire preoperatively ...

2000-09-01

 
 
 
 
41

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear techniques such as XRF, XRD, Gamma, Alpha, etc. for ...

2004-10-01

42

MTX final report  

Energy Technology Data Exchange (ETDEWEB)

The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma effects. It was consequently decided to adapt ...

1994-01-01

43

High-flux source of fusion neutrons for material and component testing  

Energy Technology Data Exchange (ETDEWEB)

The inner part of a fusion reactor will have to operate at very high neutron loads. In steady-state reactors the minimum fluence before the scheduled replacement of the reactor core should be at least l0-15 Mw.yr/m2. A more frequent replacement of the core is hardly compatible with economic constraints. A most recent summary of the discussions of these issues is presented in Ref. [l]. If and when times come to build a commercial fusion reactor, the availability of information on the behavior of materials and components at such fluences will become mandatory for making a final decision. This makes it necessary an early development and construction of a neutron source for fusion material and component testing. In this paper, we present information on one very attractive concept of such a source: a source based on a so called Gas Dynamic Trap. This neutron source was proposed in the mid 1980s (Ref. [2]; see also a survey [3] with discussion of the early stage of the ...

1999-01-07

44

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood; Aktuelle und zukuenftige Strategien in der interdisziplinaeren Therapie von Medulloblastomen, supratentoriellen PNET und intrakraniellen Keimzelltumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors cisplatin containing ...

2001-09-01

45

Fermilab Steering Group Report  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the proposed Fermilab plan ...

2007-01-01

46

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash images, respectively, good or very good ...

1997-03-01