WorldWideScience
1

Dependence of proton beam polarization on ion source transition configurations  

Energy Technology Data Exchange (ETDEWEB)

The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in ...

1997-11-11

2

Polarized electron sources  

Energy Technology Data Exchange (ETDEWEB)

Polarized electron sources for high energy accelerators took a significant step forward with the introduction of a new laser-driven photocathode source for the SLC in 1992. With an electron beam polarization of >80% and with {approximately}99% uptime during continuous operation, this source is a key factor in the success of the current SLC high-energy physics program. The SLC source performance is used to illustrate both the capabilities and the limitations of solid-state sources. The beam requirements for future colliders are similar to that of the SLC with the addition in most cases of multiple-bunch operation. A design for the next generation accelerator source that can improve the operational characteristics and at least minimize some of the inherent limitations of present sources is presented. Finally, the possibilities for producing highly ...

1995-05-01

3

Operation of the AGS polarized beam  

Energy Technology Data Exchange (ETDEWEB)

A polarized proton physics run took place during January, 1988, at the Brookhaven AGS. It is the purpose of this paper to review the tune-up period preceding that run. This was the third such run at the AGS; the others occurred in June of 1984 and February of 1986. Some comparisons will be drawn among these. A thorough review of the history and hardware associated with the acceleration of polarized protons at the AGS can be found in the proceedings of the last meeting of this group at Protvino and will not be repeated here. 2 refs., 6 figs., 1 tab.

1988-01-01

4

Uses of laser optical pumping to produce polarized ion beams  

Energy Technology Data Exchange (ETDEWEB)

Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.

1983-04-01

5

Coherent Smith-Purcell radiation in the far-infrared region from a short-bunched electron beam  

International Nuclear Information System (INIS)

Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.

1995-09-28

7

Production of polarized negative ion beams by collisional pumping  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1983-01-01

8

Production of polarized negative ion beams by ''collisional pumping''  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1984-03-01

9

Progress at LAMPF, 1992--1993  

Energy Technology Data Exchange (ETDEWEB)

This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP ...

1994-07-25

10

Beam stability study based on the beam trajectory jitter in the KEKB injector linac  

International Nuclear Information System (INIS)

... Tsukuba, Ibaraki (Japan) 389 p. PARTICLE ACCELERATORS beam monitoring

2001-08-01

11

Nuclear physics with a free electron laser  

International Nuclear Information System (INIS)

... radiation parity photonuclear reactions polarized beams resonance

12

Free electron laser and accelerator  

International Nuclear Information System (INIS)

The present report addresses several aspects of the free electron laser (FEL) and accelerator, including their features, potentials, mechanisms, beams emitted from undulator, FEL produced by helical mangnetic field, major problems with FEL, etc. In FEL, relativistic electron beams interact with an electromagnetic field with periodically changing intensity to produce coherent electromagnetic waves with variable wavelength. The capability of varying its wavelength represents the greatest advantage over conventional lasers. Any periodic magnetic field can serve as a wiggler. A wiggler can be used both in an amplifier and oscillator. A periodic magnetic field used may be either of a parallel type or of a helical type. The polarization of emitted beams depends on the shape of the magnet regardless of whether its field is parallel or helical. An equation is derived in the report which ...

1988-08-01

13

Polarizing a stored proton beam by spin flip?  

International Nuclear Information System (INIS)

We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.

2009-04-27

14

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

15

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

16

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

17

Electron-beam-plasma ion source as source of negative fluorine  

Energy Technology Data Exchange (ETDEWEB)

Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma ...

1997-11-01

18

Beam-forming system for electrostatic accelerator  

International Nuclear Information System (INIS)

A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.

1988-01-01

19

PIC Simulations Of Ion Acceleration By Linearly And Circularly Polarized Laser Pulses  

Science.gov (United States)

Linearly polarized laser radiation accelerates electrons to very high velocities and these electron form a sheath layer on the rear side of thin targets where preferentially protons are accelerated. When mass-limited targets are used, the lateral transport of the absorbed laser energy is reduced and the accelerating field is enhanced. For targets consisting of two ion species, heavier ions facilitate formation of quasi-monoenergetic bunch of lighter ions. For circularly polarized light, fast electron production is suppressed by the absence of the oscillatory component of the ponderomotive force. Ions are accelerated on the front side by the separation field and very thin foil can be accelerated as one massive quasi-neutral block. As all ion species acquire the same velocity, this acceleration mechanism is preferred for ...

2008-06-24

21

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

22

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

23

Production by surface sputtering and acceleration of heavy negative ions in tandem accelerators  

Energy Technology Data Exchange (ETDEWEB)

The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.

1992-10-05

25

Secure direct communication using the 'polarization' entangled atomic ensembles  

Energy Technology Data Exchange (ETDEWEB)

We propose a scheme with potential experimental realization to generate 'polarization' entanglement between two atomic ensembles and show one of the applications - a novel secure communication allowing asymptotically key distribution and quasisecure direct communication. The scheme involves laser manipulation of atomic ensembles, adjustable quarter- and half-wave plates, beam splitters, polarizing beam splitters and single-photon detectors, and well fits the status of the current experimental technology.

2004-02-14

26

Polarization characteristics of spontaneous emission and off-axis coherent gain in a free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

The polarization characteristics of spontaneous radiation from relativistic electrons moving through helical and planar wiggler fields are evaluated for imperfect beam injection. Maximum coherent gain in free-electron laser systems are seen to occur in optical fields having these polarization characteristics rather than those of the wiggler magnets. Coupling coefficients for an electron beam skewed at an angle to the optical mode are presented.

1995-11-01

27

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

28

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

29

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

30

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

31

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

32

A General Model of the Resistive Wall Instability in Linear Accelerators  

Energy Technology Data Exchange (ETDEWEB)

A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.

2007-01-08

34

Fourier Synthesization of Optical Pulses and "Polar'' Light  

CERN Document Server

It is shown that the direct Fourier synthesization of light beams allows one to create polarity-asymmetric waves, which are able, in the process of nonlinear interaction with a medium, to break its inversion symmetry. As a result, these "polar" waves may show the effect of optical rectification in nonlinear centrosymmetric media by generating light-induced dc electric polarization. At the same time, the waves of this type, due to their unusual symmetry properties, can be used for detecting the direction and sign of a dc electric field applied to the medium. The prospects of application of polar waves to data recording and processing are discussed.

2002-01-01

35

Status of LBL/LLNL FEL (free electron laser) research for two beam accelerator applications  

Energy Technology Data Exchange (ETDEWEB)

We review the status of free electron laser (FEL) research being conducted at LBL and LLNL as part of a broader program of research on two beam accelerators (TBAs). Induction accelerator-driven FELs for use as power sources for high-gradient accelerators are discussed, along with preliminary cost estimates for this type of power source. Finally, a promising new version of an FEL/TBA is described. 25 refs., 1 fig., 3 tabs.

1989-03-01

36

Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report  

International Nuclear Information System (INIS)

The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.

37

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at Geel, ORELA, or LANSCE/LANL; nuclear ...

1996-09-01

38

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

39

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

40

Polarized proton acceleration at the Brookhaven AGS  

Energy Technology Data Exchange (ETDEWEB)

At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.

1986-01-01

41

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

42

"Spin" and "Orbital" Flows in a Circularly Polarized Paraxial Beam: Orbital Rotation without Orbital Angular Momentum  

CERN Document Server

In light beams with circular or elliptic polarization, the transverse energy flow consists of the "spin" and "orbital" parts. Both of them can induce the orbital motion of microparticles suspended within the field of a light beam, and this should be taken into account in experiments on the spin-to-orbital angular momentum conversion. The character of the spin, orbital and total transverse energy flows in circular Laguerre-Gaussian beams is studied analytically; graphical representations of the flows in the beam cross section (flow maps) are calculated and analyzed. The spin circulatory flow can be directed oppositely to the orbital one and/or to the polarization handedness. As a result, the total transverse energy circulation of a beam with homogeneous circular polarization can be of different handedness in different ...

2009-01-01

43

Strong WW scattering at photon linear colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma}{yields}ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson. ((orig.)).

1995-02-01

44

Strong WW scattering at photon linear colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma} {yields} ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson.

1994-06-01

45

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

46

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

47

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced ...

2005-01-01

48

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

49

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

50

Polarization of high-energy electrons traversing a laser beam  

Energy Technology Data Exchange (ETDEWEB)

When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e{yields}{gamma} conversion for future {gamma}{gamma} colliders. (orig.). 16 refs.

1998-02-21

51

Polarization of high-energy electrons traversing a laser beam  

International Nuclear Information System (INIS)

When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e#->##gamma# conversion for future #gamma##gamma# colliders. (orig.).

52

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

53

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

54

IFA-2 collective ion accelerator experiments  

Energy Technology Data Exchange (ETDEWEB)

Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.

1985-10-01

55

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

56

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

57

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

58

Analysis of longitudinal bunching in an FEL driven two-beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

2000-08-01

59

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

60

Improved FNAL linac beam choppers  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.

1981-06-01

61

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy  

UK PubMed Central (United Kingdom)

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy...Full Text Available

2009-02-01

62

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

63

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

64

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

66

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

67

Electron accelerators, present and future applications  

International Nuclear Information System (INIS)

The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, ...

68

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

69

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion ...

1993-12-01

70

Optimal beam polarizations for new-physics search through {gamma}{gamma}{yields}t t-bar {yields}lX/bX  

Energy Technology Data Exchange (ETDEWEB)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-15

71

Optimal beam polarizations for new-physics search through #gamma##gamma##->#t t-bar #->#lX/bX  

International Nuclear Information System (INIS)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-01

72

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton ...

1999-01-01

73

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

74

PBG structures for multi-beam devices  

International Nuclear Information System (INIS)

Photonic band gap structures with single or multiple defects show potential for use in single-beam and multi-beam klystrons and particle accelerators. The primary concerns are the coupling between the modes at each individual defect site and the damping of unwanted higher order modes. A conceptual design of a PBG based, multi-beam klystron and methods to damp HOMs and to cool and tune the structure are presented.

2002-12-12

75

Electromagnetic effects in relativistic electron beam plasma interactions  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.

1985-02-13

76

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-01-01

77

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

78

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-04-01

79

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

80

Design study of longitudinal dynamics of the drive beam in 1 TeV relativistic klystron two-beam accelerator  

International Nuclear Information System (INIS)

In this paper the authors present a design study on the longitudinal dynamics of a relativistic klystron two-beam accelerator (RK-TBA) scheme which has been proposed as a power source candidate for a 1 TeV next linear collider (NLC). They address the issue of maintaining stable power output at desired level for a 300-m long TBA with 150 extraction cavities and present their simulation results to demonstrate that it can be achieved by inductively detuning the extraction cavities to counter the space charge debunching effect on the drive beam. They then carry out simulation study to show that the beam bunches desired by the RK-TBA can be efficiently obtained by first chopping an initially uniform beam of low energy into a train of beam bunches with modest longitudinal dimension and then using the open-quotes adiabatic captureclose quotes scheme to bunch and ...

1994-11-07

81

Free electron laser experiments using a long pulse induction linac  

International Nuclear Information System (INIS)

The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By ...

82

The polarized electron gun for the SLC  

International Nuclear Information System (INIS)

A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.

1992-03-24

83

Modulation instability of linearly polarized laser pulse in relativistic plasma  

International Nuclear Information System (INIS)

Based on the nonlinear dispersion relation of electromagnetic wave in relativistic plasma, the nonlinear controlling equation for linearly polarized mode is obtained using Karpman's method. The modulation instability of intense laser pulse propagating through relativistic plasma is analyzed and the modulation instability growth rate as a function of perturbation wave number for laser beam propagating through relativistic plasma is given. (authors)

2008-10-01

84

Assessment of the efficacy of braking radiation beam formation of electron accelerators  

International Nuclear Information System (INIS)

Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.

85

Twenty Years of Tevatron Operation  

Energy Technology Data Exchange (ETDEWEB)

The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode, accelerating a proton beam into stationary targets/detectors, as well as a Colliding Beam mode, continuously colliding counter rotating beams of protons and antiprotons. Upon completion, the Tevatron cryogenic system became the world's largest helium refrigeration system. In 1993, the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history, experiences and statistics of ...

2004-07-15

86

Development of mini-LIA and primary experiments  

International Nuclear Information System (INIS)

Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

2009-09-01

87

Multi-beamlet focusing of intense negative ion beams by aperture displacement technique  

Energy Technology Data Exchange (ETDEWEB)

Multi-beamlet focusing of an intense negative ion beam has been performed using the beamlet steering by the aperture displacement. The apertures of the grounded grid were displaced as all beamlets of 270 (18 x 15) in the area of 25 cm x 26 cm would be steered to a common point (a focal point) in both the two-stage and the single-stage accelerators. The multi-beamlets were successfully focused and the e-folding half width of 10 cm was achieved 11.2 m downstream from the ion source in both the accelerators. The corresponding gross divergence angle is 9 mrad. The negative ion beamlets are deflected by the magnetic field for the electron deflection at the extraction grid and the deflection direction oppositely changes line by line, resulting in the beam split in the deflection direction. This beamlet deflection was well compensated also using the beamlet steering by the aperture displacement of the grounded ...

1995-08-01

88

Lie Algebraic Treatment of Linear and Nonlinear Beam Dynamics  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to present a summary of new methods, employing Lie algebraic tools, for characterizing beam dynamics in charged-particle optical systems. These methods are applicable to accelerator design, charged-particle beam transport, electron microscopes, and also light optics. The new methods represent the action of each separate element of a compound optical system, including all departures from paraxial optics, by a certain operator. The operators for the various elements can then be concatenated, following well-defined rules, to obtain a resultant operator that characterizes the entire system. This paper deals mostly with accelerator design and charged-particle beam transport. The application of Lie algebraic methods to light optics and electron microscopes is described elsewhere (1, see also 44). To keep its scope within reasonable bounds, they restrict their ...

1988-12-01

89

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

90

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01

91

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-12-31

92

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-05-01

93

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode ...

94

Exclusive ?0 electroproduction on transversely polarized protons  

International Nuclear Information System (INIS)

The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum ...

2009-08-17

95

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

96

A beam funnelling demonstration: Experiment and simulation  

Energy Technology Data Exchange (ETDEWEB)

Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the ...

1990-01-01

97

Plasma production and flow in negative ion beams  

Science.gov (United States)

Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.

1977-09-21

98

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

99

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment ...

1995-03-01

100

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin ...

2008-08-01

101

Apparatus for producing controlled positive or negative corona discharge for semiconductor materials processing  

Energy Technology Data Exchange (ETDEWEB)

An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.

1984-09-01

102

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

103

The new Tevatron beam position monitor front-end software  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron is a proton anti-proton accelerator collider operating at the Fermi National Accelerator Laboratory. The machine is currently delivering beam for the CDF and D0 experiments, which expect increasing luminosity until the conclusion of Run II, planned for 2009. The Laboratory defined a plan for achieving higher luminosity, and one of the tasks is the upgrade of the accelerator's beam position monitor (BPM). The Tevatron was built during the early eighties and some of its control systems, including the BPMs, are still the original ones. This paper describes the front-end software of the Tevatron BPM upgrade, from the requirements to the implementation, and the underlying hardware setup. The front-end software designed is presented, emphasizing its modularity and reusability, allowing it to be applied to other Fermilab machines.

2005-05-01

104

Standing-Wave Free-Electron Laser Two-Beam Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set.

1991-02-01

105

Optical pressure on thin film caused by a Gaussian beam-generated evanescent wave  

International Nuclear Information System (INIS)

The optical pressure exerted o a thin film, which is locked in the evanescent field formed at the plane interface with a totally-reflected Gaussian beam, is investigated. Some calculations of the pressure on the film caused by the evanescent field are presented in the different conditions of film thickness, film position, incident angle and polarization of a gaussian beam. The results show that the pressure exertion on the thin film can change from pushing to pulling as the parameters are varied. In particular, we find that the direction of optical pressure can act oppositely at the different positions of the film surface in the evanescent field.

1994-11-01

106

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting ...

2008-09-01

107

Works on the start-up of an infrared free-electron laser in FIAN  

International Nuclear Information System (INIS)

The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL

2000-10-17

108

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion power plants are now projected to be cost-competitive with other conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization ...

1988-02-01

109

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

International Nuclear Information System (INIS)

A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion power plants conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are ...

110

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

111

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up ...

2006-01-01

112

Conceptual design of industrial free electron laser using superconducting accelerator  

International Nuclear Information System (INIS)

Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.

1995-08-21

113

The two-beam accelertor  

Energy Technology Data Exchange (ETDEWEB)

The Two-Beam Accelerator (TBA) consists of a long high-gradient accelerator structure (HGS) adjacent to an equal-length Free Electron Laser (FEL). In the FEL, a beam propagates through a long series of undulators. At regular intervals, waveguides couple microwave power out of the FEL into the HGS. To replenish energy given up by the FEL beam to the microwave field induction accelerator units are placed periodically along the length or the FEL. In this manner it is expected to achieve gradients of more than 250 MV/m and thus have serious option for a 1 TeV /times/ 1 TeV linear collider. The state of present theoretical understanding of the TBA is presented with particular emphasis upon operation of the ''steady-state'' FEL, phase and amplitude control of the rf wave, and suppression of sideband instabilities. Experimental work ...

1987-08-01

114

Air breakdown induced by a high-power short-pulse microwave  

Energy Technology Data Exchange (ETDEWEB)

At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for microwave-induced air breakdown and the experimental procedure are explained. The results ...

1996-05-01

115

Field emission dark current of technical metallic electrodes  

International Nuclear Information System (INIS)

In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.

2007-04-21

116

Proton G{sub E}/G{sub M} from beam-target asymmetry  

Science.gov (United States)

The ratio of the proton's electric to magnetic form factor, G{sub E}/G{sub M}, can be extracted in elastic electron-proton scattering by measuring cross sections, beam-target asymmetry, or recoil polarization. Separate determinations of G{sub E}/G{sub M} by cross sections and recoil polarization observables disagree for Q{sup 2}>1 (GeV/c){sup 2}. Measurement by a third technique might uncover an unknown systematic error in either of the previous measurements. The beam-target asymmetry has been measured for elastic electron-proton scattering at Q{sup 2} = 1.51 (GeV/c){sup 2} for target spin orientation aligned perpendicular to the beam momentum direction. This is the largest Q{sup 2} at which G{sub E}/G{sub M} has been determined by a beam-target asymmetry experiment. The result, {mu}G{sub E}/G{sub M}=0.884{+-}0.027{+-}0.029, is compared to previous ...

2006-09-15

117

High-Gain Lasing and Polarization Switch with a Distributed Optical-Klystron Free-Electron Laser  

International Nuclear Information System (INIS)

This Letter reports the first experimental results from the world's first distributed optical-klystron (DOK) free-electron laser (FEL), the DOK-1 FEL, at Duke University. The DOK-1 FEL is a hybrid system, comprised of four wigglers: two horizontal and two helical. With the DOK-1 FEL, we have obtained the highest FEL gain among all storage ring based FELs at 47.8% (#+-#2.7%) per pass. We have also demonstrated that the FEL gain can be enhanced by increasing electron bunching using wigglers with a different polarization. Furthermore, we have realized controlled polarization switches of the FEL beam by a nonoptical means through the manipulation of a buncher magnet.

2006-06-09

118

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

119

Particle acceleration by stimulated emission of radiation near a solid-state active medium  

British Library Electronic Table of Contents (United Kingdom)

We report acceleration of electrons moving in free space near an active Nd:YAG slab. The power of a non-relativistic beam of electrons has increased by more than 30% when the medium was excited. It is demonstrated experimentally that the energy gained by the electrons is linearly proportional to the energy stored in the medium. Moreover, the energy gain traces closely the population inversion inferred by monitoring the spontaneous radiation.

2011-01-01

120

High-brightness photoemitter development for electron accelerator injectors  

Energy Technology Data Exchange (ETDEWEB)

Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.

1985-01-01

121

BNL Neutral Beam Development Group. Progress report, FY 1983 and final report  

Energy Technology Data Exchange (ETDEWEB)

The BNL Neutral Beam Development Group has been active in the program for the development of high energy, high power neutral beam systems since 1973. These injectors are based on the production, acceleration and neutralization of negative hydrogen or deuterium ions and are supposed to be used for plasma heating and current drive in the next generation of fusion devices. Over the span of 10 years the group has studied plasma-surface type of negative hydrogen ion sources, transport and acceleration of negative ion beams and neutralization of negative ions in gases and plasmas. As the required source parameters (current, pulse length, efficiency) were changing over this period of time, the group developed several types of sources, resulting finally in the design of a steady state device operating with an excellent gas efficiency and having the possibility of scaling-up to the size ...

1984-03-16

122

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are ...

123

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of ...

2002-06-01

124

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage ...

2000-03-01

125

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...

1998-11-06

126

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the ...

2009-06-17

127

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams ...

2008-02-01

128

Summary and closing remarks  

Energy Technology Data Exchange (ETDEWEB)

A summary of the topics covered in papers presented at the 1995 Brookhaven joint conference on production, neutralization, and application of negative ion beams is given. The conference topics covered included plasma ion sources, plasma seeding of these sources for increased ion production, beam extraction and transport, computer simulation and design studies, and operation of existing and experimental ion source facilities. Application of the sources to accelerator, tokamak, and thin film deposition are discussed. (AIP) {copyright} {ital 1996 American Institute of Physics.}

1996-07-01

129

JAS'2000  

CERN Multimedia

Are you interested in beam dynamics? Do you work on the LHC injectors or CLIC or maybe feasibility studies fornew machines? Then this is for youJAS'2000: Joint CERN-Japan-JINR-Russia-US SchoolFrontiers of Accelerator Technology: High Quality Beams to be held on a river boat between St. Petersburg and Moscow 1 to 14 July 2000. For further information see eitherhttp://schools.web.cern.ch/Schools/CAS/ orhttp://www.indiana.edu/~uspas/programs/js/jas2000.html

2000-01-01

130

High gain 10.6-micron free-electron laser amplifier  

International Nuclear Information System (INIS)

A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.

1988-11-02

131

Implications of the Electrostatic Approximation in the Beam Frame on the Nonlinear Vlasov-Maxwell Equations for Intense Beam Propagation  

Energy Technology Data Exchange (ETDEWEB)

This paper develops a clear procedure for solving the nonlinear Vlasov-Maxwell equations for a one-component intense charged particle beam or finite-length charge bunch propagating through a cylindrical conducting pipe (radius r = r(subscript)w = const.), and confined by an applied focusing force. In particular, the nonlinear Vlasov-Maxwell equations are Lorentz-transformed to the beam frame ('primed' variables) moving with axial velocity relative to the laboratory. In the beam frame, the particle motions are nonrelativistic for the applications of practical interest, already a major simplification. Then, in the beam frame, we make the electrostatic approximation which fully incorporates beam space-charge effects, but neglects any fast electromagnetic processes with transverse polarization (e.g., light waves). The resulting Vlasov-Maxwell ...

2001-11-08

132

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

133

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1981-01-01

134

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

International Nuclear Information System (INIS)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1980-09-01

135

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, ...

2010-01-01

136

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

137

Relative luminosity measurement of the LHC with the ATLAS forward calorimeter  

CERN Document Server

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.

2010-01-01

138

Pencil-like mm-size electron beams produced with linear inductive voltage adders  

International Nuclear Information System (INIS)

We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.

139

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

1999-01-01

140

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

1999-08-31

141

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

142

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

143

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

144

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

145

Elise plans and progress  

International Nuclear Information System (INIS)

Elise is a heavy ion induction linear accelerator that will demonstrate beam manipulations required in a driver for inertial fusion energy. With a line charge density similar to that of heavy ion drivers, Elise will accelerate a #>=# 1 gs beam pulse of K"+ ions from an initial energy of 2 MeV to a final energy #>=# 5 MeV. In the present design, the Elise electrostatic quadrupoles (ESQ) will have a 2.33 cm radius aperture operating at #+-#59 kV. The half-lattice periods range from 21 cm to 31 cm. The entire machine will be approximately 30 m long, half of that is the induction accelerator and the remaining half is the injector (including the Marx generator) and the matching section. Elise will be built in a way that allows future expansion into the full ILSE configuration, therefore it will have an array of four ESQ focusing channels capable of transporting up to a total of 3.2 ...

1995-09-06

146

Distributed Grating-Assisted Coupler for Optical All-Dielectric Electron Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A Bragg waveguide consisting of multiple dielectric layers with alternating index of refraction becomes an excellent option to form electron accelerating structure powered by high power laser sources. It provides confinement of a synchronous speed-of-light mode with extremely low loss. However, laser field can not be coupled into the structure collinearly with the electron beam. There are three requirements in designing input coupler for a Bragg electron accelerator: side-coupling, selective mode excitation, and high coupling efficiency. We present a side coupling scheme using a distributed grating-assisted coupler to inject the laser power into the waveguide. Side coupling is achieved by a grating with a period on the order of an optical wavelength. The phase matching condition results in resonance coupling thus providing selective mode excitation capability. The coupling efficiency is limited by profile matching between ...

2005-09-23

147

Selection and design of ion sources for use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ...

1994-06-01

148

Tensor polarization of the residual nucleus in the "6Li (#alpha#, #alpha#') "6Li (2.18 MeV, 3"+) reaction at E_#alpha# = 27.2 MeV  

International Nuclear Information System (INIS)

The experiment on the determination of the tensor polarization of the residual nucleus is described for the reaction "6Li (#alpha#, #alpha#') "6Li. It is based on the unique connection of polarization tensors t_l_m of the residual nucleus for the reaction (#alpha#, #alpha#') and the angular correlation function W (#omega#_1, #omega#_2) for #alpha#'-particle and decay product of this nucleus, where #omega#_1, #omega#_2 are motion directions of #alpha#'-particle and decay product. The angular correlations of #alpha#'-particle and deuteron are measured for the "6Li (#alpha#, #alpha#', d)"4He reaction on the 27.2 MeV #alpha#-particle beam. The recording system consists of six silicon detectors and provides the energy resolution about 0.8 MeV and the angular resolution #+-# 3 deg. The polarization tensors of the residual nucleus "6Li (2.185 MeV, 3"+) are determined as the result of measuring the angular ...

1999-01-01

149

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

150

Depth profile of uncompensated spins in an exchange bias system  

Energy Technology Data Exchange (ETDEWEB)

We have used the unique spatial sensitivity of polarized neutron and soft x-ray beams in reflection geometry to measure the depth dependence of magnetization across the interface between a ferromagnet and antiferromagnet. The new uncompensated magnetization near the interface responds to applied field, while the uncompensated spins in the antiferromagnetic bulk are pinned, thus providing a means to establish exchange bias.

2005-05-17

151

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to ...

1988-07-01

152

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce ...

1988-01-01

153

Production of negative ions by electron impact. Final report 1 May 81-31 Oct 82  

Science.gov (United States)

Proposed future space-based beam weapons systems will most probably require an intense neutral particle beam for effective operation across geomagnetic field lines. Such neutral beams can most efficiently be obtained by stripping excess electrons from negative ion beams. The objective of this work is to study the process of dissociative attachment of electrons. Specifically, to measure the cross sections for polar dissociation and dissociative attachment for production of H(-). It is suspected that these dissociative attachment cross sections for the production of H(-) from alkali hydrides are large. The insight gained from this study will be extremely helpful in the fabrication of high current density H(-) beam sources for use in the production of intense neutral hydrogen beams. A selection of alkali hydride molecules will be investigated ...

1982-10-01

154

Production, transport and injection of a cold non-magnetized electron beam for the recirculating linac  

International Nuclear Information System (INIS)

A new foilless diode with a non-magnetically immersed cathode was recently designed and built for the Sandia Recirculating Linear Accelerator (RLA). Because there is also no radial component of electric field at the cathode, the electron beam starts almost parallel and is matched to a solenoidal transport system with minimum increase in divergence and radius. The electrode emission surface is specified by an area covered with felt which undergoes explosive electron emission at low electrical field stresses (60 kV/cm). The 1.7 MV, 4.8-kA produced beam is transported 1.5 meters to the injection region of the racetrack via a system of solenoids and focusing coils. The maximum transverse velocity component at injection point (1.5 m downstream from the cathode surface) is #beta# perpendicular = 0.03 and the radius r = 2.8 cm which give a quite small beam emittance #epsilon# = 0.08 rad-cm. Three- dimensional ...

1989-06-01

155

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the ...

1997-01-17

156

AECL IMPELA electron beam industrial irradiators  

International Nuclear Information System (INIS)

A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 ...

157

Micro-patterning of chemical functionality of anthracene-bis-resorcinol film using focused ion beam  

International Nuclear Information System (INIS)

Anthracene-bis-resorcinol is an interesting molecule as it forms a hydrogen-bonded network when guest molecules with weak polarity are included. Focused ion beam (FIB) was irradiated on a part of its amorphous film with low dose, and the film was exposed to the vapor of guest molecules. From fluorescence and AFM analyses of this film, it was found that no inclusion compound was formed in FIB irradiated area, i.e. FIB irradiation suppresses the ability to form the inclusion compounds. By utilizing this phenomenon, we succeeded in a microfabrication of relief structures consisting of inclusion compounds which has different fluorescence from its surrounding. Morphology, fluorescence, and IR absorption analyses indicated that hydroxyl or resorcin groups are damaged by ion beams, and consequently a formation of hydrogen-bonded networks, which play a role of a lattice caging guest molecules, becomes impossible.

2005-12-15

158

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that ...

159

The Fermilab Linac Upgrade  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Linac Upgrade is planned to increase the energy of the H- linac from 200 to 400 MeV. This is intended to reduce the incoherent space-charge tuneshift at injection into the 8 GeV Booster which can limit either the brightness or the total intensity of the beam. The Linac Upgrade will be achieved by replacing the last four 201.25 MHz drift-tube tanks which accelerate the beam from 116 to 200 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of abut 7.5 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. Each accelerator module will be driven with a klystron-based rf power supply. A prototype rf modulator has been built and tested at Fermilab, and a prototype 12 MW klystron is being fabricated by Litton Electron Devices. Fabrication of production accelerator modules is in progress. 8 ...

1991-02-01

160

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

161

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

162

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...

1991-10-02

163

The compact linear collider CLIC  

CERN Document Server

A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A ...

2004-01-01

164

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator ...

1992-03-16

165

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

166

PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.

2006-06-26

167

Noninvariance of space/time-scale ranges under a Lorentz transformation and the implications for the study of relativistic interactions  

International Nuclear Information System (INIS)

The summary of this report is: (1) The range of scales #LAMBDA# of a system is not a Lorentz invariant and can vary greatly for some systems. (2) There exists an optimum frame which minimizes #LAMBDA#. (3) We demonstrated speedup of x1000 for PIC simulation of relativistic beam interacting with electron background. (4) It is not in contradiction with the conventional scientific wisdom that 'complexity' is an invariant. (5) We identified three domains of application (laser-plasma acceleration, e-cloud in HEP accelerators, free electron lasers) for which speedup ranging from 2 to 4 orders of magnitude were demonstrated on toy problems.

168

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

169

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.

2009-10-19

170

Proposal for a free electron laser driven by the 7 MeV NILPRP linac  

International Nuclear Information System (INIS)

The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)

171

Los Alamos Advanced Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.

1991-01-01

172

Linac Coherent Light Source Experiments Commence  

British Library Electronic Table of Contents (United Kingdom)

The Linac Coherent Light Source [1] (LCLS) at SLAC National Accelerator Laboratory is preparing for the arrival of its first scientific users in the fall of 2009. LCLS is the world's first free-electron in the spectral range 800-8,000 eV, producing intense, sub-picosecond pulses of Xrays with very high spatial coherence. The accelerator facility has been commissioned in stages, beginning in April 2007 [2] with the injector linac and culminating in December 2008 [3] with the first transport of electrons through the complete beam path. On April 10, 2009, the LCLS Project team was rewarded for years of planning, design, construction, and checkout with a dream-come-true: as undulators were placed on the beam path one-by-one, the laser simply turned on without drama in the course of one hour [4...

2009-01-01

173

Developments of linacs for ADTT in the USA  

Energy Technology Data Exchange (ETDEWEB)

Interesting developments in linear accelerators have been attained over the past 45 years. The status of linear accelerators and future possibilities are described in context of demanding applications and technology maturity. Features of industrial or `factory`-type applications are high availability, economic operations, low investment cost and ease of running a facility. All features have been demonstrated in one manner or another at large operating facilities for the research community; within a different context that has been argued in the past to be not as demanding as for `factory` installation. In addition, comments are made relative to intense beam power levels and choices that can be made for power levels below 10 MW, on the assumption that a cw beam is required. 1 fig., 1 tab.

1997-09-01

174

Characteristics of the 18 MeV medical linear accelerator 'NELAC-1018', 2. Electron beams  

Energy Technology Data Exchange (ETDEWEB)

The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.

1983-11-01

175

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the ...

2002-01-01

176

State-of-the-Art developments in accelerator controls at the APS.  

Energy Technology Data Exchange (ETDEWEB)

The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control ...

1999-04-13

177

Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 5  

Energy Technology Data Exchange (ETDEWEB)

This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory Editing and changes to the authors` contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on nine presentations: ``The Energy Exchange and Efficiency Consideration in Klystrons``, ``Some Properties of Microwave RF Sources for Future Colliders + Overview of Microwave Generation Activity at the University of Maryland``, ``Field Quality Improvements in Superconducting Magnets for RHIC``, ``Hadronic B-Physics``, ``Spiking Pulses from Free Electron Lasers: Observations and Computational Models``, ``Crystalline Beams in Circular Accelerators``, ``Accumulator Ring for AGS & Recent AGS Performance``, ``RHIC Project Machine Status``, and ``Gamma-Gamma Colliders.``

1995-10-01

178

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

179

Programmed improvements of the alternating gradient synchrotron complex at Brookhaven National Laboratory, Upton, New York. Environmental assessment  

Energy Technology Data Exchange (ETDEWEB)

The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to ...

1994-03-01

180

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

Energy Technology Data Exchange (ETDEWEB)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H{sup 1+} alone up to Bi{sup 1+}, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He{sup -} and O{sup -} have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)

1993-07-01

181

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

International Nuclear Information System (INIS)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H1+ alone up to Bi1+, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He- and O- have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)

1993-09-22

182

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not ...

183

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy ...

184

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data ...

1999-07-01

185

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can ...

2008-02-21

186

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

187

A thermal hydraulic investigation on ADSR liquid lead target  

Energy Technology Data Exchange (ETDEWEB)

Computational fluid dynamics(CFD) code FLUENT was used to simulate the thermal hydraulic processes occurring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly. When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.

1998-05-01

188

Simulation of a Standing-Wave Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

The standing-wave free-electron laser (FEL) differs from a conventional linear-wiggler microwave FEL in using irises along the wiggler to form a series of standing-wave cavities and in reaccelerating the beam between cavities to maintain the average energy. The device has been proposed for use in a two-beam accelerator (TBA) because microwave power can be extracted more effectively than from a traveling-wave FEL. The standing-wave FEL is modeled in the continuum limit by a set of equations describing the coupling of a one-dimensional beam to a TE{sub 01} rectangular-waveguide mode. Analytic calculations and numerical simulations are used to determine the time variation of the reacceleration field and the prebunching required so that the final microwave energy is the same in all cavities. The microwave energy and phase are found to be insensitive to modest spreads in the beam energy ...

1990-09-01

189

Improved method for producing negative ion beams from the group IIA elements for tandem Van de Graaff applications  

Energy Technology Data Exchange (ETDEWEB)

A brief description of a method for producing relatively intense molecular negative ion beams for the difficult Group IIA elements is given which offers considerable improvement in terms of source operation and beam intensity stability over other methods conventionally utilized. It is particularly suited for use in cesium plasma sources such as the Aarhus geometry and axial geometry versions of the source. The method utilizes H/sub 2/ source feed gas for the production of a hydrogen-rich plasma discharge which sputters a negatively biased probe made of elemental or copper alloy material. Negative ion beams of MgH/sub 3//sup -/>=12 ..mu.. A have been realized during routine operation of the 25 MV tandem accelerator. Negative ion beam intensity data, typical source operational parameters, and examples of mass spectra associated with their production are given. Interesting ...

1983-06-01

190

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

191

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} ...

2002-01-01

192

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider ...

1994-11-14

193

Mott-Schwinger Scattering of Polarized Low Energy Neutrons up to Thermal Energies  

Energy Technology Data Exchange (ETDEWEB)

The availability of new, high-intensity, cold and thermal neutron sources has opened the possibility of performing high-precision fundamental neutron physics experiments, including measurements that study the hadronic weak interaction and standard model test measurements, using neutron decay. The observables in these experiments are usually correlated with the direction of neutron polarization and are often very small (10 8 10 6). Mott-Schwinger scattering of polarized neutrons can produce spin-dependent shifts in beam centroids, which has the potential to produce significant systematic effects for these types of experiments. An accurate calculation of this process for neutral atoms and basic molecules has not been carried out for low neutron energies. In this work, we derive a general expression for the electromagnetic (Mott-Schwinger) contributions to the analyzing power for low-energy neutron scattering. We obtain ...

2008-10-01

194

Measurements of single and double spin asymmetry in pp elastic scattering in the CNI region with a polarized atomic hydrogen gas jet target  

International Nuclear Information System (INIS)

Precise measurements of the single spin asymmetry AN, and the double spin asymmetry ANN, in proton-proton (pp) elastic scattering in the region of four-momentum transfer squared 0.0012 have been performed using a polarized atomic hydrogen gas jet target and the Relativistic Heavy Ion Collider (RHIC) polarized proton beam. We present measurements of AN and ANN at center-of-mass energies ?(s)=6.8 and 13.7 GeV. These spin-dependent observables are sensitive to the poorly known hadronic spin-dependent amplitudes. Comparing AN at different energies, a ?(s) dependence of the hadronic single spin-flip amplitude is suggested. A hadronic double spin-flip amplitude from the ANN data is consistent with zero within a 2-? level. We also present ??T, estimated from the measured ANN data. The results for ??T are consistent with zero. Our results provide significant constraints toward a comprehensive understanding of the reaction mechanism ...

2009-05-01

195

High-power, high-brightness pseudospark-produced electron beam driven by improved pulse line accelerator  

Energy Technology Data Exchange (ETDEWEB)

A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its ...

1995-12-31

196

Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM  

Energy Technology Data Exchange (ETDEWEB)

During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised ...

1995-12-31

197

High-power radio frequency pulse generation and extraction based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides  

International Nuclear Information System (INIS)

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power ...

198

Isobaric analog resonances in "8"9Y  

International Nuclear Information System (INIS)

Three resonances at the proton energies 7.0, 7.08, and 7.53 MeV on the target "8"8Sr were chosen to investigate the possibility of determining the amplitudes of the weak coupling experimentally. The corresponding "8"9Sr levels under investigation were 1.93 MeV ("5/_2"+), 2.00 MeV ("3/_2"+), and 2.46 MeV ("3/_2"+). Angular distributions were measured on resonance at 7.0, 7.08, and 7.53 MeV from proton inelastic scattering to the 1.84 MeV (2"+) state of "8"8Sr for differential cross section, analyzing power, spin-flip probability, and spin-flip asymmetry. A polarized beam of protons was used to obtain the analyzing power. The spin-flip probability was obtained from the coincidence of the prompt gamma rays from the (p,p'#gamma#) reaction with the scattered protons. With the polarized beam, the gamma coincidence technique was further used to obtain a spin-flip asymmetry measurement. From these measurements, ...

199

(Evaluation of the high intensity plasma sputer negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams)  

Energy Technology Data Exchange (ETDEWEB)

A working visit was made to the National Laboratory for High Energy Physics, Tsukuba, Japan, during the time periods May 16, 1988--June 15, 1988 for the purposes of further evaluation of the high intensity plasma sputter negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams. During the visit, the traveler worked in collaboration with Japanese scientists in installing and testing of the source on the University of Tsukuba tandem electrostatic accelerator injector. During the course of preliminary testing of the ion source and prior to actual injection into the accelerator, sparking began in one or more tube sections, which ultimately led to the decision to replace the damaged tube sections. This problem led to postponement of the scheduled tandem accelerator tests. The traveler ...

1988-07-06

200

SUSY at e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e{gamma} {yields} (e tilde)(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde and bar)(f tilde) could enable us to constrain the basic parameters in ...

1994-04-01

201

SUSY at e#gamma#/#gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e tilde)(Z tilde)_1 and #gamma##gamma# #-># (f tilde and bar)(f tilde) could enable us to constrain the basic parameters in the MSSM. This is ...

1994-04-01

202

Study of GaSb+Bi system by proton backscattering method  

International Nuclear Information System (INIS)

The thermal stability of diffusion barriers is explored on the basis of Bi films at different expedients of deriving of films. The examinations were conducted on the electrostatic accelerator at KNU of name Karazin V.N. under conditions of an isothermal bakeout directly under a proton beam of 1,85 MeV energy.

203

Research accomplishments and future goals in particle physics  

Energy Technology Data Exchange (ETDEWEB)

This document presents our proposal to continue the activities of Boston University researchers in eight projects in high energy physics research: Colliding Beams Physics; Accelerator Design Physics; MACRO Project; Proton Decay Project; Theoretical Particle Physics; Muon G-2 Project; and Hadron Collider Physics. The scope of each of these projects is presented in detail in this paper.

1990-01-05

204

Proceedings of the meeting on the technical study at KEK  

International Nuclear Information System (INIS)

Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)

2006-11-28

205

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

206

Planning and Operation of Commercial Application Center  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this R and D project are as follows : First, transferring developed technologies to outside companies and operating technology market to vitalize technology transactions, Second, developing commercial application projects to transfer technologies for commercial purposes and to solve interface problems in commercial applications, Third, enhancing commercial utilizations of developed accelerator and beam utilization technologies, Finally. preparing infra-structures for the development of over 30 venture- businesses based on achieved technologies through the Proton Engineering Frontier Project.

2003-06-15

207

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

208

Development of a new secondary beam separator and a new gas-jet target at Kyushu University  

International Nuclear Information System (INIS)

In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).

1994-06-01

209

A multi-megawatt X-band solid state microwave switch  

Energy Technology Data Exchange (ETDEWEB)

The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.

1995-12-31

210

The influence of target backing on ion-beam electron spectra  

International Nuclear Information System (INIS)

Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).

211

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a frequency broadening of ...

2002-05-20

212

Large-Scale Simulation of Beam Dynamics in High Intensity Ion Linacs Using Parallel Supercomputers  

CERN Document Server

In this paper we present results of using parallel supercomputers to simulate beam dynamics in next-generation high intensity ion linacs. Our approach uses a three-dimensional space charge calculation with six types of boundary conditions. The simulations use a hybrid approach involving transfer maps to treat externally applied fields (including rf cavities) and parallel particle-in-cell techniques to treat the space-charge fields. The large-scale simulation results presented here represent a three order of magnitude improvement in simulation capability, in terms of problem size and speed of execution, compared with typical two-dimensional serial simulations. Specific examples will be presented, including simulation of the spallation neutron source (SNS) linac and the Low Energy Demonstrator Accelerator (LEDA) beam halo experiment.

2000-01-01

213

CLUSTER: a high frequency H-mode coupled cavity linac for low and medium energies  

CERN Document Server

We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER, which stands for "Coupled-cavity Linac USing Transverse Electric Radial field". In order to compare the performance of this structure with other hadrontherapy linac designs involving high frequencies, a conceptual study has been performed for an operating frequency of 3 GHz. Moreover a proof of principle has been obtained through RF measurements on a prototype operating at 1 GHz. An accelerator complex using a CLUSTER linac is also considered for protontherapy purposes. The whole complex is called cyclinac and is ...

2006-01-01

214

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that ...

215

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

216

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, ...

2010-05-01

217

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the ...

2000-11-27

218

Pulse power considerations for the generation of 45 #mu#s, 200 keV electron beams for CO_2 lasers  

International Nuclear Information System (INIS)

A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is ...

1989-01-19

219

Optimal parameters for energy spectral calculations of mega voltage photon beam using Monte Carlo simulations  

International Nuclear Information System (INIS)

For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron ...

2005-06-01

220

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment  

Energy Technology Data Exchange (ETDEWEB)

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the ...

2009-01-29

221

Dynamics of a very intense pulsed electron beam  

Energy Technology Data Exchange (ETDEWEB)

A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be ...

1994-12-31

222

Using of beam spoilers in linear accelerators with photons of 10 MV  

International Nuclear Information System (INIS)

This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the ...

1998-11-22

223

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...

1995-08-21

224

High voltage high brightness electron accelerator with MITL voltage adder coupled to foilless diode  

International Nuclear Information System (INIS)

The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.

1995-10-13

225

Versatile high intensity plasma sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. Illustrative examples of ...

1988-07-01

226

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

Energy Technology Data Exchange (ETDEWEB)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 {mu}s) after reaching the stop band of the resonance. Dedicated ...

2010-07-01

227

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

International Nuclear Information System (INIS)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 #mu#s) after reaching the stop band of the resonance. Dedicated ...

2010-03-15

228

Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider  

Energy Technology Data Exchange (ETDEWEB)

Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...

2005-09-18

229

Electron diodes and cavity design for the new 4-MeV injector of the recirculating linear accelerator (RLA)  

International Nuclear Information System (INIS)

The authors have designed and constructed four types of electron-beam diodes for the new 4-MV RLA injector: a non-immersed foilless diode, a magnetically immersed foilless diode, a foil diode and an ion-focused foilless diode, They are tailored to fit the new injector cavity. The design goals were to produce high quality 10-kA to 20-kA electron beams with a #beta# perpendicular smaller than 0.2 and a beam radius of the order of 2 cm. These beams will be matched to the RLA IFR channel so #beta# perpendicular must be equal to or smaller than the square root of the ratio of the beam current versus Alfven current for f_e = 1. A reentrant anode geometry was selected for the injector cavity design, because it offers substantial savings on the required amount of feromagnetic cores. The inner radius of the outside shell, now only 30 cm, would have been twice as large (60 cm) if a coaxial ...

1991-03-01

230

Dipole response of {sup 88}Sr up to the neutron-separation energy  

Energy Technology Data Exchange (ETDEWEB)

Dipole and quadrupole excitations in the semimagic N{sup .} = 50 nucleus {sup 88}Sr were investigated at the superconducting electron linear accelerator ELBE with bremsstrahlung produced at electron energies of 9.0, 13.2, and 16.0 MeV. About 160 {gamma} transitions were identified up to 12 MeV. By using polarized photons linear polarizations of about 50 {gamma} transitions were measured. In the energy range of 6 - 12 MeV there is only one M1 transition while all other transitions have E1 character. Statistical methods were applied in order to filter out inelastic transitions and to correct the intensities of the ground-state transitions for their branching ratios. The photoabsorption cross section obtained in this way provides information about the extension of the Giant Dipole Resonance towards energies below the neutron-separation energy. The experimental results are compared with existing data beyond the ...

2007-07-01

231

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the ...

2008-02-15

232

Halogens for negative ion beams and ion-ion plasmas  

International Nuclear Information System (INIS)

Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of ...

2007-07-01

233

Microwave axial free-electron laser with enhanced phase stability  

International Nuclear Information System (INIS)

Free-electron laser (FEL) amplifiers have demonstrated high efficiencies and high output power at microwave wavelengths. However, measurements and simulations have indicated that the present level of phase stability for these devices is not sufficient for driving linear accelerators. Fluctuations in the diode voltage, which is needed to accelerate the electron beam, are the largest cause of the shifts in the phase of the output power. Pulse-power technology cannot keep the voltage fluctuations less than 1/4%. However, we have found a scheme that will make the output phase much less sensitive to these fluctuations by exploiting the traveling wave nature of the FEL interaction. In this paper we study the phase stability issue by analyzing the dispersion relation for an axial FEL, in which the rf field is transversely wiggled and the electron trajectories are purely longitudinal. The advantage of using the axial FEL ...

1995-08-21

234

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

235

e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics noteworthy in e#gamma# colliders, abnormal gauge coupling, the ...

1994-02-01

236

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and ...

1997-02-28

237

E{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is explained. As for the physics noteworthy in e{gamma} colliders, ...

1994-02-01

238

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials ...

2007-08-01

239

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.

1996-12-31

240

Energy saver A-sector power test results  

Energy Technology Data Exchange (ETDEWEB)

The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.

1982-09-15

241

Construction and development of a UV free electron laser under the cooperation of Nihon U, KEK, PNC, ETL and Tohoku U  

Energy Technology Data Exchange (ETDEWEB)

The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.

1995-12-31

242

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

243

TTF HOM Data Analysis with Curve Fitting Method  

Energy Technology Data Exchange (ETDEWEB)

To investigate the possibility of using HOM signals induced in SC cavities as beam and cavity diagnostics, narrow band (20 MHz) data was recorded around the strong TE111-6(6{pi}/9-like) dipole modes (1.7 GHz) in the 40 L-band (1.3 GHz) cavities at the DESY TTF facility. The analyses of these data have so far focused on using a Singular Value Decomposition (SVD) technique to correlate the signals with each other and data from conventional BPMs to show the dipole signals provide an alternate means of measuring the beam trajectory. However, these analyses do not extract the modal information (i.e., frequencies and Q's of the nearly degenerate horizontal and vertical modes). In this paper, we described a method to fit the signal frequency spectrum to obtain this information, and then use the resulting mode amplitudes and phases together with conventional BPM data to determine the mode polarizations and relative centers ...

2009-07-14

244

Smith-Purcell radiation in the highly relativistic regime  

International Nuclear Information System (INIS)

An electron moving over the surface of a diffraction grating will transfer a part of its kinetic energy to radiation via a velocity synchronous coupling with a slow space harmonic component of the field. Since the phase velocity of a slow space harmonic is less than the speed of light, the slow components decay exponentially, or evanesce, with distance above the grating and the evanescence scale is determined by the product of the relative velocity, #beta#, the relative energy, #gamma#, and the wavelength #lambda#. Thus, in the relativistic regime, good electron - grating coupling can be maintained at beam heights that are greater than the emitted wavelength. In order to explore this regime a series of experiments have been carried out with moderately energetic beams and an experiment with the 70-MeV beam at the Accelerator Test Facility is in the planning stage. The work has two basic goals: the first ...

1995-08-21

245

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) ...

1981-01-01

246

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

Energy Technology Data Exchange (ETDEWEB)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The ...

2009-06-15

247

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

International Nuclear Information System (INIS)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The ...

2009-06-01

248

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection ...

1997-02-01

249

Radioisotope production in the I.Ph.P.E. cyclotron for medical application  

International Nuclear Information System (INIS)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tu-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle ...

250

Radioisotope production in the I. Ph. P. E. cyclotron for medical application  

Energy Technology Data Exchange (ETDEWEB)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle ...

1982-01-01

251

Accelerator technology program. Progress report, April-December 1978  

Science.gov (United States)

This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and ...

1980-05-01

252

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...

2011-05-05

253

Beam Motes  

ScienceCinema

...english the ...

254

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

255

Production of radioisotopes in the ORNL 86-inch cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The radioisotope production facilities and programs of the 86-Inch Cyclotron are reviewed in this presentation. The 86-Inch Cyclotron is designed to accelerate protons to a maximum energy of 22 MeV for internal targets. These protons are used to bombard metals that are electroplated, potted or soldered to water-cooled plates. Additionally, metals and inorganic compounds are bombarded in water-cooled tube targets. High radioisotope production rates are obtained by beam currents as large as 3 mA. Production rates for /sup 11/C, /sup 57/Co, /sup 67/Ga, /sup 68/Ge, /sup 109/Cd, and other isotopes are presented. The production of /sup 11/C for the carboxyl labeling of amino acids in cooperation with Oak Ridge Associated Universities is discussed. The 86-Inch Cyclotron is used for those programs requiring a larger beam current than is available from commercial cyclotrons.

1981-04-01

256

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

257

Physical properties of wood-polymer composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

The dual characteristics in the performance of polymers in wood-polymer composites systems have been pursued with regard to the resolution of mechanical anisotropy of wood and the improvement in dimensional stability. The objective of the present study is to pursue the polymerization mechanism in wood under electron beam irradiation and the temperature dependence of polymer-wood interactions induced at various levels of higher order structure of wood in order to understand the polymer performance. Veneers used in the study were of rotary-cut beech (Fagus crenata Blume) 0.65 mm thick. All samples were oven-dried in vacuo at 80/sup 0/C for 30 hr. The monomers used in the study were methyl methacrylate, styrene, acrylic acid, acrylonitrile, and unsaturated polyester. Experimental details are given. Results are given and discussed.

1981-01-01

258

Nuclear astrophysics with radioactive ion beams  

International Nuclear Information System (INIS)

Nuclear astrophysics seeks for a possible explanation of the observed abundance distribution of various elements and their isotopes in the universe. Most of the relevant nuclear reactions take place in thermally equilibrium environments with bare nuclei, rather than accelerated and head-on colliding situations with low ionisation states of reactant atoms and molecules that are emulated in the laboratories. Moreover, the temperature of the astrophysical environments is quite often low compared to the centre-of-mass energy of the projectile nuclides, that is required for the reaction to be meaningfully investigated in the laboratory. Therefore, an extrapolation of the data on the reaction cross sections to very low energies and to extremely high density situations is generally called for, which are substantially altered every now and then for a number of astrophysically important reactions. The radioactive ion beams will provide us important data ...

259

2007 2008 ACADEMIC TRAINING PROGRAMME  

CERN Multimedia

LECTURE SERIES 14, 15, 17 January 2008 11:00 to 12:00 - Council Chamber, bldg. 503-1-001 Applications of accelerators to tumour therapy U. AMALDI, TERA Foundation & University of Milano Bicocca The first lecture is devoted to an historical review of the developments of the teletherapy techniques which make use of hadron beams and are collectively called "hadrontherapy". The main emphasis is on the use of protons and light ions, but also neutrons, pions and antiprotons are considered. The second lecture reviews the rationale behind the use of carbon ions in the treatment of radioresistant tumours and the results obtained both with proton and carbon ion beams on the 60 000 patients treated worldwide. The numbers of patients who would profit from hadrontherapy are presented together with the current landscape of running and planned hospital based centres. The main technical challenges set by this therapeutic modality are ...

2007-01-01

260

1. 55 [mu]m buried ridge stripe laser diodes grown by gas source molecular beam epitaxy  

Energy Technology Data Exchange (ETDEWEB)

Buried ridge stripe lasers have been grown on InP in two steps by gas source molecular beam epitaxy. The active structure consists of a compressively strained layer multi quantum well with an equivalent wavelength emission at 1.5 [mu]m. The stripe was defined by reactive ion etching. A threshold current of 22 mA was reproducibly obtained on a laser length of 500 [mu]m. A CW output power of 48 mW per facet was achieved. In addition, preliminary accelerated aging tests have shown the high reliability the structure. (orig.)

1993-02-01

261

The effect of the primary collimator and flattening filter on asymmetric fields for a Siemens PRIMUS linear accelerator  

CERN Document Server

Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under ...

2005-01-01

262

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, conventional cavities support a ...

2001-05-31

263

Versatile charged particle activation technique for the analysis of the noble metals  

Energy Technology Data Exchange (ETDEWEB)

The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements (PGE) and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a tandem Van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.

1982-01-01

264

Versatile charged particle activation technique for the analysis of the noble metals  

Energy Technology Data Exchange (ETDEWEB)

The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a Tandem van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.

1983-01-01

265

Transverse Resistive Wall Wakefunction with Inductive Bypass  

CERN Document Server

Charged particle beams in circular accelerators couple with their surroundings through induced electromagnetic fields. This interaction can be described by so-called coupling impedances. In the frequency domain the impedance in connection with the bunch spectrum allows for stability analysis and estimates. However, for simulation codes one usually needs the wakefunction, the equivalent of the impedance in time domain. Recently the transverse impedance of a cylindrical pipe with arbitrary surface impedance was given by L. Vos. An expression for the wakefunction of this transverse resistive wall impedance with inductive bypass is derived here.

2003-01-01

266

Self-seeded injection-locked FEL amplifier  

Energy Technology Data Exchange (ETDEWEB)

A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.

1998-12-01

267

Radiation control aspects of the civil construction for a high power free electron laser (FEL) facility  

International Nuclear Information System (INIS)

The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.

1996-11-06

268

Properties of composite materials on the base of radiation-hardening binders and metal powders  

International Nuclear Information System (INIS)

Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.

269

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

270

Interest of a two-dimensional matrix of detectors for the quality control of beams in static or dynamic mode; Interet d'une matrice bidimensionnelle de detecteurs pour le controle de qualite des faisceaux en mode statique ou dynamique  

Energy Technology Data Exchange (ETDEWEB)

A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)

2007-11-15

271

Identification of the #pi#g_9_/_2 band new levels in "1"2"1Cs  

International Nuclear Information System (INIS)

The #pi#g_9_/_2 band structure in "1"2"1Cs is obtained. The experiment was performed at the HI-13 MV tandem accelerator of China Institute of Atomic Energy. The excited states of "1"2"1Cs were populated via the reaction "1"1"2Sn("1"2C, p2n). The #gamma#-#gamma# coincidence data were taken with five BGO-AC HpGe detectors at beam energy of 60 Mev. The energy-level schemes of "1"2"1Cs is presented.

1992-01-01

272

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

273

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

274

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

275

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

276

CyberKnife SRS: new technologies that enhance the treatment of cancer  

International Nuclear Information System (INIS)

The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision

2008-11-26

277

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

278

Basic Science Beamline(TR104) at PEFP  

International Nuclear Information System (INIS)

PEFP(Proton Engineering Frontier Project) is developing beamlines for various application fields by using the high current 100MeV proton linear accelerator. Beamlines were characterized and categorized by the beam energy, average currents, and irradiation conditions. Among these beamlines the TR104 is designed for the basic science and the research of the aerospace. Before the construction and installation of beamlines, we try to practice and prepare the detail process of installation by the precedent study of TR104 beamline in KAERI site. By this work installation process was checked and confirmed for the same condition of the PEFP site

2010-10-01

279

Observations of plasma wave turbulence generated around large ionospheric spacecraft: Effects of motionally induced EMF and of electron beam emission  

International Nuclear Information System (INIS)

The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam ...

280

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer  

International Nuclear Information System (INIS)

Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. ...

1992-06-01

281

Charge and fluence lifetime measurements of a dc high voltage GaAs photogun at high average current  

Energy Technology Data Exchange (ETDEWEB)

GaAs-based dc high voltage photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. This paper describes techniques to maintain good vacuum while delivering beam, and techniques that minimize the ill effects of ion bombardment, the dominant mechanism that reduces photocathode yield of a GaAs-based dc high voltage photogun. Experimental results presented here demonstrate enhanced lifetime at high beam currents by: (a) operating with the drive laser beam positioned away from the electrostatic center of the photocathode, (b) limiting the photocathode active area to eliminate photoemission from regions of the photocathode that do not support efficient beam delivery, (c) using a large ...

2011-04-01

283

Fermilab Steering Group Report  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a ...

2007-01-01

284

Proton-proton scattering above 3 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

A large set of data on proton-proton differential cross sections, analyzing powers and the double-polarization parameter A{sub NN} is analyzed employing the Regge formalism. We find that the data available at proton beam momenta from 3GeV/c to 50GeV/c exhibit features that are very well in line with the general characteristics of Regge phenomenology and can be described with a model that includes the {rho}, {omega}, f{sub 2}, and a{sub 2} trajectories and single-Pomeron exchange. Additional data, specifically for spin-dependent observables at forward angles, would be very helpful for testing and refining our Regge model. (orig.)

2010-09-15

285

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

286

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

287

Modelling the effects of measured anode triple-phase boundary densities on the performance of micro-tubular hollow fiber SOFCs  

British Library Electronic Table of Contents (United Kingdom)

The percolated or active triple phase boundary (TPB) length per unit volume of Ni-YSZ anode hollow fibers (HFs) containing 60wt.% initial NiO and a spatially varying microstructure were measured using a focused ion beam (FIB)-SEM technique. The measured values of contiguous TPB density were interfaced with a 2-D distributed finite element model of a hollow fiber solid oxide fuel cell. The model was applied to simultaneously solve the ionic and electronic charge balances in the electrodes, which were modelled as overlying continuum materials with effective electronic and ionic conductivities. The model was used to predict the effects of anode microstructure on the distribution of current density, and anode activation polarization. Active TPB lengths of 2.63-8.63 m^-^2 were measured for the ...

2011-01-01

288

A concept for the experimental determination of the nucleon electric to magnetic form factor ratio at very low Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

Stationary target measurements of the nucleon form factors have been performed with high precision down to Q{sup 2} of {approx} 0.01 GeV{sup 2} for protons (G{sub E}{sup p}) and down to {approx} 0.1 GeV{sup 2} for neutrons (G{sub M}{sup n}). Conventional extraction using cross section and polarization measurement cannot be extended to very low values of Q{sup 2} due to inherent experimental limitations. We present a proposal for a new approach to a measurement, using colliding beams, which will extend the range of possible measurement at low Q{sup 2} by several orders of magnitude over stationary target limits.

2009-05-15

289

A concept for the experimental determination of the nucleon electric to magnetic form factor ratio at very low Q2  

International Nuclear Information System (INIS)

Stationary target measurements of the nucleon form factors have been performed with high precision down to Q2 of ? 0.01 GeV2 for protons (GEp) and down to ? 0.1 GeV2 for neutrons (GMn). Conventional extraction using cross section and polarization measurement cannot be extended to very low values of Q2 due to inherent experimental limitations. We present a proposal for a new approach to a measurement, using colliding beams, which will extend the range of possible measurement at low Q2 by several orders of magnitude over stationary target limits.

2009-05-01

290

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of calculation techniques were ...

2000-04-01

291

Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator  

International Nuclear Information System (INIS)

The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by ...

2002-09-21

292

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning  

CERN Document Server

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning

1998-01-01

296

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

297

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this ...

298

High-frequency electrostatic waves near Earth's bow shock  

International Nuclear Information System (INIS)

Electrostatic wave measurements from the Active Magnetospheric Particle Tracer Explorer Ion Release Module have been used to investigate the wave modes and their possible generation mechanisms in the Earth's bow shock and magnetosheath. It is demonstrated that electrostatic waves are present in the bow shock and magnetosheath with frequencies above the maximum frequency for Doppler-shifted ion acoustic waves, yet below the plasma frequency. Waves in this frequency range are tentatively identified as electron beam mode waves. Data from 45 bow shock crossings are then used to investigate possible correlations between the electrostatic wave properties and the near-shock plasma parameters. The most significant relationships found are anticorrelations with Alfven Mach number and electron beta. Mechanisms which might produce electron beams in the shock and magnetosheath are discussed in terms of the correlation study results. These mechanisms include ...

299

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-07-01

300

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-08-18

301

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and welding. By first method we could not ...

2006-11-01

302

CERN Academic Training Programme 2008/2009  

CERN Multimedia

LECTURE SERIES 8, 9, 10 11 & 12 June 2009 11:00-12:00 - Main Auditorium, Bldg. 500 Scenarios and Technological Challenges for a LHC Luminosity Upgrade: Introduction to the LHC Upgrade Program and Summary of Physics Motivations After a general introduction to the motivations for a LHC upgrade, the lectures will discuss the beam dynamics and technological challenges of the increase of the LHC luminosity, and the possible scenarios. Items such as a stronger final focus with larger aperture magnets, crab cavities, electron cloud issues, beam-beam interaction, machine protection and collimation will be discussed.Monday 8 June 2009 Introduction to the LHC upgrade program - L. Evans Summary of Physics Motivations - M. Mangano Tuesday 9 June 2009 The Dectector Upgrade and the Requirements on the Upgrade Scenarios - M. Nessi Wednesday 10 June 2009 Scenarios for the LHC Luminosity Upgrade - F. Zimmermann Thursday 11 June 2009 Main ...

2009-01-01

303

Demonstration of a wide-band compact free electron laser to the THZ imaging of bio samples  

International Nuclear Information System (INIS)

We have developed a compact terahertz (THz) free electron laser (FEL). The FEL operates in the wavelength range of 100-1200 #mu#m, which corresponds to 0.3-3 THz. THz radiation from the FEL shows much higher power of 100 W compared to the power level, <100 mW, of the table-top sources by conventional lasers. The THz FEL beam shows good performance in pulse-energy stability, polarization, spectrum and spatial distribution. The main application of the FEL is THz imaging for bio-medical researches. We demonstrated the THz imaging of bugs for living condition at 3 THz. The bugs were died just before experiments, so they were not dried. We could get transmitted information through the samples by using the THz FEL beam. In this paper, we will estimate and discuss the required power level of the THz source for the practical application of the imaging.

2007-05-21

304

Calibrating the energy of a 50x50 GeV muon collider using spin precession  

International Nuclear Information System (INIS)

The neutral Higgs boson is expected to have a mass in the region 90 endash 150thinspGeV /c"2 in various schemes within the minimal supersymmetric extension of the standard model. A first generation muon collider is uniquely suited to investigate the mass, width, and decay modes of the Higgs boson, since the coupling of the Higgs boson to muons is expected to be strong enough for it to be produced in the s channel mode in the muon collider. Because of the narrow width of the Higgs boson, it is necessary to measure and control the energy of the individual muon bunches to a precision of a few parts in a million. We investigate the feasibility of determining the energy scale of a muon collider ring with circulating muon beams of 50thinspGeV energy by measuring the turn by turn variation of the energy deposited by electrons produced by the decay of the muons. This variation is caused by the existence of an average initial polarization of the muon ...

1998-07-01

305

Development of a high-current microwave ion source for proton linac application systems  

International Nuclear Information System (INIS)

A microwave hydrogen ion source was developed to improve reliability, and to increase operation time of proton linac application systems. The ion source needs no filament in the discharge chamber, which leads to better reliability and less maintenance time. The developed source produced a maximum hydrogen ion beam current of 70 mA (high current density of 360 mA/cm2, beam energy of 30 keV) with a 5 mm diam extraction aperture and 1.2 kW microwave power. The proton fraction was increased with an increase in rf power and reached around 90% at 1 kW. Measured 90% beam normalized emittance was 0.4 #pi# mm mrad. Rise times of rf power and beam current to 90% of the final values were about 30 and 35 #mu#s, respectively, at a pulse operation mode with 400 #mu#s pulse width and 100 Hz repetition rate. The dynamic range of beam currents was enlarged (3-63 mA) in the pulse mode with a modified ...

2004-05-01

306

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, ...

2005-04-01

307

Higgs, SUSY and the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property of the scalar sector can be explored in ...

2001-10-11

308

Higgs, SUSY and the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by making use of linear ...

2001-10-11

309

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify ...

310

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and ...

2007-05-01

311

First Result of Induction Acceleration in the KEK Proton Synchrotron  

CERN Document Server

First Result of Induction Acceleration in the KEK Proton Synchrotron

2005-01-01

312

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

313

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...

314

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using ...

1995-08-21

315

Review of High Gain FELs  

Science.gov (United States)

For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons from the atoms contained in the crystal. Therefore, total power in ...

2007-01-19

316

Industrial applications of the Jefferson Lab high-power free-electron laser  

International Nuclear Information System (INIS)

In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already ...

1998-09-02

317

EB-curing of coatings on wood composite boards  

International Nuclear Information System (INIS)

The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, ...

1988-10-01

318

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...

2003-01-01

319

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

320

Photophysical properties of new psoralen derivatives: psoralens linked to adenine through polymethylene chains  

International Nuclear Information System (INIS)

The model compounds, 8-methoxypsoralen-CH_2O(CH_2)_n-adenine (MOPCH_2OC_nAd, n=2,3,5,6,8, and 10) in which 5 position of 8-methoxypsoralen (8-MOP) is linked by various lengths of polymethylene bridge to N"9 of adenine. UV absorption spectra are identical with the sum of MOPCH_2OC3 and adenine absorption spectra. Solvent effect on the UV absorption and fluorescence emission spectra indicate that the lowest excited singlet state is the (#pi##->##pi#"*) state. The spectral characteristics of the fluorescence of MOPCH_2OC_nAd are strongly dependent upon the nature of the solvents. The fluorescence emission spectra in aprotic solvents are broad and structrueless due to the excimer formation through the folded conformation accelerated by hydrophobic #pi#-#pi# stacking interaction. Increasing polarity of the protic solvents leads to higher population of unfolded conformation stabilized through favorable solvation and H-bonding, and consequently to ...

2002-10-01

321

VLEPP based photon linear collider 100x100 GeV with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

The possible parameters of a photon linear collider at its ultimate luminosity, based on the VLEPP physics and technology V.E. Balakin et al., Proc. 6th Nat. Conf. on Accelerators, Dubna, 1978; V.E. Balakin, Proc. 4th Int. Workshop on Next Generation Linear Colliders, Garmisch, 1992, are presented. At a photon energy of 100x100 GeV the maximum achievable luminosity is about 1x10{sup 36} cm{sup -2} s{sup -1}. Beam parameters, luminosity characteristics, and ways to reduce the background are considered as well. ((orig.)).

1995-02-01

322

TLA monitoring of an anodic protection system  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs.

1992-03-01

323

TLA monitoring of an anodic protection system  

International Nuclear Information System (INIS)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs.

324

Reversed light-dark cycle and cage enrichment effects on ethanol-induced deficits in motor coordination assessed in inbred mouse strains with a compact battery of refined tests  

British Library Electronic Table of Contents (United Kingdom)

The laboratory environment existing outside the test situation itself can have a substantial influence on results of some behavioral tests with mice, and the extent of these influences sometimes depends on genotype. For alcohol research, the principal issue is whether genotype-related ethanol effects will themselves be altered by common variations in the lab environment or instead will be essentially the same across a wide range of lab environments. Data from 20 inbred strains were used to reduce an original battery of seven tests of alcohol intoxication to a compact battery of four tests: the balance beam and grip strength with a 1.25g/kg ethanol dose and the accelerating rotarod and open-field activation tests with 1.75g/kg. The abbreviated battery was then used to study eight inbred str...

2011-01-01

325

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

326

Monte Carlo treatment planning for photon and electron beams  

British Library Electronic Table of Contents (United Kingdom)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...

2007-01-01

327

ITER baffle module small-scale mock-ups: first wall thermo-mechanical testing results  

International Nuclear Information System (INIS)

The EU-home team is in charge of the R and D related to the ITER baffle first wall. Five small-scale mock-ups, using Be, CFC and W tiles and different armour/heat-sink material joints under development, have been fabricated and thermomechanically tested in FE200 (Le Creusot) and JUDITH (Juelich) electron beam facilities. The small-scale mock-ups have been submitted to thermo-mechanical fatigue tests (up to failure using accelerating techniques). The objective was to determine the performances of the armour material joints under high heat flux cycles. (orig.)

1998-09-01

328

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The physics and technological issues involved in high gradient particle acceleration at high microwave (RF) frequencies are under study at MIT. The 17 GHz photocathode RF gun has a 1 1/2 cell ({pi} mode) room temperature cooper cavity. High power tests have been conducted at 5-10 MW levels with 100 ns pulses. A maximum surface electric field of 250 MV/m was achieved. This corresponds to an average on-axis gradient of 150 MeV/m. The gradient was also verified by a preliminary electron beam energy measurement. Even high gradients are expected in our next cavity design.

1995-12-31

329

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

330

Design and installation of a low particulate, ultrahigh vacuum system for a high power free-electron laser  

International Nuclear Information System (INIS)

A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.

1999-03-01

331

Coherent spontaneous radiation from highly bunched electron beams  

International Nuclear Information System (INIS)

Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.

1995-08-21

332

Modular coherence of protein dynamics in yeast cell polarity system  

UK PubMed Central (United Kingdom)

In this study, we investigated on a systems level how complex protein interactions underlying cell polarity in yeast determine the dynamic association of proteins with the polar cortical domain (PCD)...Full Text Available

2011-05-03

333

Establishment and expression of cellular polarity in fucoid zygotes.  

UK PubMed Central (United Kingdom)

Zygotes of fucoid algae have long been studied as a paradigm for cell polarity. Polarity is established early in the first cell cycle and is then expressed as localized growth and invariant cell division....Full Text Available

1992-06-01

334

Sub-wavelength localization of near-fields in coupled metallic spheres for single emitter polarization analysis  

CERN Document Server

We numerically demonstrate selective near-field localization determined by the polarization state of a single emitter coupled to plasmonic nano-cluster. Seven gold nanospheres are carefully arranged such that up to ten polarization states of the single emitter, including linear, circular, and elliptical polarizations, can be distinguished via the distinct field localization in four gaps. The ability to transform polarization state into field spatial localization may find application for single emitter polarization analysis.

2011-01-01

335

Verification of electron beam therapy with storage phosphor images: Precision of field placement  

Energy Technology Data Exchange (ETDEWEB)

Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis placed on this aspect ...

1990-04-01

336

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an ...

2007-04-01

337

Manufacture of wood/plastic composites by radiation  

International Nuclear Information System (INIS)

The manufacture and use of wood/plastic composite (WPC) as an example of wood matrix and wood sawdust/plastic composites (SDP) as an example of plastic matrix are reviewed. The raw material for WPC are mostly vinyl monomers, particularly methyl methacrylate and styrene. The reaction in WPC polymerization is radical polymerization. Researches on the radiation sources mostly resulted in gamma-ray. Electron beam can be applied only to thin products. The future use of WPC may be for furnitures, sporting goods, decorative parts and the like. Vital study on the reduction of manufacturing costs is required, for example, the improvement of reaction and the adoption of continuous process must be considered. The raw materials for SDP are wood sawdust, vinyl monomer (mostly methyl methacrylate) and resins. Electron beam accelerators are the most preferable radiation source because of its high efficiency and safe operation. SDP shows ...

1976-01-01

338

Electron beam processing of rubber wood fibers - polypropylene composites. Effects of reactive additives on the physical and mechanical properties  

International Nuclear Information System (INIS)

The purpose of this study is to determine the suitability of producing agro-fiber reinforced plastic composite (agro-FRPC) from rubber wood fiber blended in polypropylene matrix. The effects of varying fiber dimension and fiber content on the physical and mechanical properties of the composite were evaluated to provide an insight into the fiber matrix adhesion. The effects of reactive additives on the physical and mechanical properties of the composite were evaluated which provides the insight on the reinforcement of the composite. Rubber wood fiber used in this study is currently being used in the manufacturing of medium density fiber (MDF) board. Two sizes of rubber wood fiber were used i.e. 0.5-1.0 mm and 1.0-2.0 mm. Homopolymer polypropylene of MFI 14.0 was used as a matrix. The irradiation work was carried out using electron beam accelerator, 3.0 MeV, 3.0 mA. Various types of reactive additives (RA) with mono-functional, di-functional, ...

2000-03-13

339

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest ...

2007-03-15

340

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest that Al or Be as ...

2007-03-01

341

A conceptual design study of superconducting proton linac for Neutron Science Project. 1  

Energy Technology Data Exchange (ETDEWEB)

The Neutron Science Project at Japan Atomic Energy Research Institute has been proposed for the research of nuclear transmutation technology and the basic science with a spallation neutron source. The project calls for an 8MW proton linac which accelerates 5.3mA average current cw and pulsed beams up to 1.5GeV. The superconducting (SC) rf-cavity is the main option for the energy part from 100MeV to 1.5GeV because by using the SC structure, less power is consumed in cw operation than by using a normal conducting (NC) structure. A conceptual design study of the superconducting proton linac is reported. The SC linac is composed of 8 {beta} sections. Each section has the identical 5-cell cavities with the surface peak field of 16MV/m. The total number of cavities is 284, and the length of the SC linac is 690m. The lattice design is determined with the equipartitioned condition and the matched envelope equations for the minimum emittance growth. The ...

1998-09-01

342

Beam-beam compensation activities at Fermilab. R and D status  

International Nuclear Information System (INIS)

The beam-beam interaction in the Tevatron produce the betatron tune spread in each bunch and a bunch-to-bunch tune spread. The tune spread sets limits on bunch intensity and luminosity. The beam-beam effects for antiprotons are usually more severe since the proton bunch population is higher. The beam-beam effects for antiprotons can in principle be compensated with the use of an electron beam with a corresponding charge density. The status of studies of possibilities of the beam-beam compensation is reviewed in this paper.

1999-06-09

343

Phosphatidylinositol 4,5-bisphosphate Directs Spermatid Cell Polarity and Exocyst Localization in Drosophila  

UK PubMed Central (United Kingdom)

During spermiogenesis, Drosophila melanogaster spermatids coordinate their elongation in interconnected cysts that become highly polarized,...Full Text Available

2010-05-01

344

On the spontaneous emergence of cell polarity  

UK PubMed Central (United Kingdom)

Diverse cell polarity networks require positive feedback for locally amplifying distributions of signalling molecules at the plasma membrane1. Additional...Full Text Available

2008-08-14

345

Space charge field in a FEL with axially symmetric electron beam  

Energy Technology Data Exchange (ETDEWEB)

Nonlinear two-dimensional theory of the space charge of an axially symmetric electron beam propagating in combined right-hand polarized wiggler and uniform axial guide fields in a presence of high-frequency electromagnetic wave is presented. The well-known TE{sub 01} mode in a cylindrical waveguide for the model of radiation fields and paraxial approximation for the wiggler field are used. Space charge field components are written in the Lagrange coordinates by the twice averaged Green`s functions of two equally charged infinitely thin discs. For that {open_quotes}compensating charges{close_quotes} method is applied in which an electron ring model is substituted by one with two different radii and signs discs. On this approach the initial Green`s functions peculiarities are eliminated and all calculations are considerably simplified. Coefficients of a twice averaged Green`s function expansion into a Fourier series are obtained by use of ...

1995-12-31

346

Simultaneous production of "2"8Mg and "4"7Ca by high-energy heavy-ion irradiation for applications in biology  

International Nuclear Information System (INIS)

With the aim of preparing carrier-free "2"8Mg and "4"7Ca simultaneously, Ti, V and Fe targets were examined by irradiating with high-energy ions of "1"2C, "1"4N and "1"6O accelerated by the RIKEN ring cyclotron. Among the targets, V gave the highest cross section for the formation of both "2"8Mg and "4"7Ca irrespective of the kind of beams. The cross section for the formation of "2"8Mg by the reactions of Ti, V and Fe targets with ion beams increased in the order of "1"2C<"1"6O<"1"4N. On the other hand, the three beams exhibited almost the same cross sections for the formation of "4"7Ca by the reaction of a given target. Titanium and V were selected as prospective targets and "1"4N as a suitable beam for the production of "2"8Mg and "4"7Ca. Chemical separation procedures of the radiotracers in carrier- and salt-free states have been established by using cation exchange resins. ...

347

Silund Nanosecond High-Current Linear Induction Accelerator ...  

Science.gov (United States)

... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...

1972-07-13

348

Rayleigh Laser Guide Star Systems UnISIS Bow Tie Shutter and CCD39 Wavefront Camera  

CERN Document Server

Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.

2002-01-01

349

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the ...

2010-01-01

350

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

351

Characterization and nanopatterning of Ni{sub 2}MnIn Heusler films  

Energy Technology Data Exchange (ETDEWEB)

The Heusler alloy Ni{sub 2}MnIn is a promising material as spin injector because of its predicted half-metallicity at the interface to InAs. We grow thin films of this Heusler alloy by thermal coevaporation of Nickel and the alloy MnIn. The alloy is grown on Si{sub 3}N{sub 4} membranes and amorphous carbon films for transmission-electron microscopy (TEM) as well as on Si and InAs. The degree of the transport spin polarization of the films grown on Si(100), InAs(100) and in-situ cleaved (110) surfaces of InAs is determined by point-contact Andreev reflection spectroscopy (PCAR). The almost perfect lattice match between InAs and Ni{sub 2}MnIn supports highly oriented growth, as we have proven by electron diffraction under grazing incidence. Lateral spin valves with Heusler electrodes are lithographically defined. In view of the temperature-sensitivity of the optical and electron-beam resists, the samples are grown at substrate temperatures of 50 ...

2008-07-01

352

Monte Carlo simulation of electron cones used in electron beam therapy  

International Nuclear Information System (INIS)

A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. ...

1998-09-01

353

MTX final report  

Energy Technology Data Exchange (ETDEWEB)

The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma effects. It was ...

1994-01-01

360

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

361

Studies of accelerated compact toruses  

Energy Technology Data Exchange (ETDEWEB)

In an earlier publication we considered acceleration of plasma rings (Compact Torus). Several possible accelerator configurations were suggested and the possibility of focusing the accelerated rings was discussed. In this paper we consider one scheme, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focusing) during acceleration. Because the allowable acceleration force, F/sub a/ = kappaU/sub m//R where (kappa < 1), increases as R/sup -2/, the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case, however, since the accelerating flux can expand as the ring ...

1983-01-04

362

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose ...

2006-02-07

363

Implementation of an algorithm for absorbed dose calculation in high energy photon beams at off axis points  

International Nuclear Information System (INIS)

Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. ...

2008-10-19

364

Development of novel brasses to resist dezincification  

Energy Technology Data Exchange (ETDEWEB)

The effect of alloying Sn, Pb, As, Sb and P on the dezincification of commercial brass 60Cu-39Zn-1Pb has been investigated in 1% CuCl{sub 2} solution by immersion studies and electrochemical measurements. Specimens with a smooth surface finish exhibited more resistance to dezincification. Appreciable inhibitive effect on dezincification was observed for the 55Cu-40Zn-3Pb-2Sn brass composition. The galvanic coupling of lead phase with the matrix accelerated corrosion. To improve the dezincification resistance of the Sn containing brass, As, Sb and P were added at two different levels (0.05% and 0.1%). Brass of composition 48.95Cu-45Zn-5Pb-1Sn-0.05As was more resistant indicating the synergistic effect of Sn and As. The effect of 0.05 and 0.1% of arsenic addition with various concentrations of zinc was also studied. The alloy of composition 57.90Cu-40Zn-2Pb-0.1As showed better corrosion resistance than the alloy containing 1% Sn and 0.05% As ...

2007-03-15

367

Total skin electron beam therapy for cutaneous lymphomas and leukemias  

International Nuclear Information System (INIS)

Total skin electron beam therapy (TSEB) was used in the treatment of 33 patients with lymphoma and 13 patients with leukemia involving extensive segments of the skin surface. Twenty-two of 23 had lesions as a primary manifestation of lymphoma (primary cutaneous lymphoma-PCL) and 11 developed cutaneous lesions following disseminated nodal lymphoma (secondary cutaneous lymphoma-SCL). A once weekly fractionation scheme was employed to irradiate the entire skin surface with 3.5 to 4 MeV electron beam from a 6 MeV linear accelerator. During each weekly session, 400 rad were delivered to the entire skin and a complete course consisted of 4-6 consecutive weekly sessions. The majority of patients have been previously treated elsewhere for various periods and all patients have been at risk for a median of 12 months, range from 12-117 months following TSEB. Striking predominance of the diffuse pattern (76%) was demonstrated in both ...

368

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator ...

2003-08-17

369

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning ...

1995-10-01

370

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of gallium ions (Ga+) ...

2003-05-09

371

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, ...

2005-11-04

372

Four-fermion production at {gamma}{gamma} colliders: 1. Lowest-order predictions and anomalous couplings  

Energy Technology Data Exchange (ETDEWEB)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes {gamma}{gamma}{yields}4f and {gamma}{gamma}{yields}4f{gamma} in the standard model and extensions thereof by an effective {gamma}{gamma}H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes {gamma}{gamma}{yields}4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of various contributions to cross sections, ...

2004-08-01

373

Four-fermion production at #gamma##gamma# colliders: 1. Lowest-order predictions and anomalous couplings  

International Nuclear Information System (INIS)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes #gamma##gamma##->#4f and #gamma##gamma##->#4f#gamma# in the standard model and extensions thereof by an effective #gamma##gamma#H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes #gamma##gamma##->#4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of various contributions to cross sections, ...

2004-08-01

374

Stabilization of synchrotron radiation beam at HASYLAB  

Energy Technology Data Exchange (ETDEWEB)

At DORIS II/HASYLAB a vertical beam position control system is in regular operation. It controls the position and angle of a photon beam simultaneously, and can stabilize beam movements up to frequencies of 0.1 Hz. To suppress beam vibrations up to 50 Hz and above, a prototype beam stabilization system for these frequencies was built and tested successfully. The present beam oscillations at the HASYLAB beamlines are explained, the quality of the beam position control system and the results of the prototype test are presented.

1989-07-01

376

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

377

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

378

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white x-ray ...

1989-07-01

379

Study of in-medium $\\omega$ meson properties in Ap, pA and AA collisions  

CERN Document Server

We propose to investigate the in-medium properties of vector $\\omega$ mesons at the normal nuclear density in Ap(pA) collisions and at higher density in AA collisions at the ITEP accelerator facility TWAC. Using of the inverse Ap kinematics will permit us to study the $\\omega$ meson production in a wide momentum interval included the not yet explored range of small meson momenta relative to the projectile nuclei where the mass modification effect in nuclear matter is expected to be the strongest. Momentum dependence of the in-medium $\\omega$ meson width will be studied in the traditional pA kinematics. We intend to use the electromagnetic calorimeter for reconstruction of the $\\omega$ meson invariant mass by detecting photons from the $\\omega \\to \\pi^{0}\\gamma \\to 3\\gamma$ decay. The model calculations and simulations with RQMD generator show feasibility of the proposed experiment. Available now intensity of the ion beams provides a ...

2008-01-01

380

Structure and kinetics of Sn whisker growth on Pb-free solder finish  

Energy Technology Data Exchange (ETDEWEB)

Standard Leadframes used in surface mount technology are finished with a layer of eutectic SnPb for passivation and for enhancing solder wetting during reflow. When eutectic SnPb is replaced by Pb-free solder, especially the eutectic SnCu, a large number of Sn whiskers are found on the Pb-free finish. Some of the whiskers are long enough to become shorts between the neighboring legs of the leadframe. How to suppress their growth and how to perform accelerated test of Sn whisker growth are crucial reliability issues in the electronic packaging industry. In this paper, we report the study of spontaneous Sn whisker growth at room temperature on eutectic SnCu and pure Sn finishes. Both compressive stress and surface oxide on Sn are necessary conditions for whisker growth. Structure and stress analyses by using the micro-diffraction in synchrotron radiation are reported. Cross-sectional electron microscopy, with samples prepared by focused ion beam, ...

2002-07-11

381

State-in-the-art of applications of shock wave research and its future; Shogekiha no oyo gijutsu no genjo to shorai  

Energy Technology Data Exchange (ETDEWEB)

A shock wave appears when the release of accumulated energy is instantaneous. For instance, it accompanies gunpowder explosion, electric discharge, laser beam convergence, collision of high-speed objects, release of high-pressure gas, and supersonic flight. The shock wave research center of Institute of Fluid Science, Tohoku University, is engaged in researches to elucidate the basics of various shock wave phenomena and to apply the fruit to engineering, science, and medicine. In this report, some examples of recent application studies at the center are described, and the trend of shock wave researches in the future is introduced. The ultimate state of the stagnation point of a nozzle flow simulating a reentry into the atmosphere is produced by shock wave compression in a free piston shock tube which is a ground-borne experimental apparatus. Los Alamos National Laboratory, U.S., succeeded in generating metallic hydrogen of a crystalline structure by subjecting ...

1999-03-15

382

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University ...

1992-01-01

383

Proton exchange membranes prepared by grafting of styrene/divinylbenzene into crosslinked PTFE membranes  

International Nuclear Information System (INIS)

Thin PTFE membranes were prepared by coating the PTFE dispersion onto the aluminum films. Thus the thin crosslinked PTFE (RX-PTFE) membranes were obtained by means of electron beam irradiation above the melting temperature of PTFE under oxygen-free atmosphere. The RX-PTFE membranes were pre-irradiated and grafted by styrene with or without divinylbenzene (DVB) in liquid phase. The existence of DVB accelerated the initial grafting rate. The styrene grafted RX-PTFE membranes are white colored, on the other hand, the styrene/DVB grafted RX-PTFE membranes are colorless. The proton exchange membranes (PEMs) were obtained by sulfonating the grafted membranes using chlorosulfonic acid. The ion exchange capacity (IEC) values of the PEMs ranging from 1.5 to 2.8 meq/g were obtained. The PEMs made from the styrene/DVB grafted membranes showed higher chemical stability than those of the styrene grafted membranes under oxidative circumstance.

2005-07-01

384

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...

1997-12-31

385

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at ...

386

Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN  

CERN Document Server

CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine circumference [3]. This has requested the undertaking of an ...

1996-01-01

387

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

388

Construction of the ATLAS end cap electromagnetic calorimeter and study of its performances; Construction du bouchon du calorimetre electromagnetique d'ATLAS et etudes de ses performances  

Energy Technology Data Exchange (ETDEWEB)

ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam tests performed at ...

2002-09-01

389

Brookhaven highlights. [Fiscal year 1992, October 1, 1991--September 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides ...

1992-12-31

390

Brookhaven highlights  

Energy Technology Data Exchange (ETDEWEB)

This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides ...

1992-01-01

391

Vibrational population dynamics in liquids and glasses: IR pump-probe experiments from 10 K to 300 K  

Energy Technology Data Exchange (ETDEWEB)

The temperature dependent vibrational relaxation of the CO stretching mode of Rhodium dicarbonyl acetylacetonate (Rh(CO){sub 2}(acac)) and tungsten hexacarbonyl (W(CO){sub 6}) in dibutylphthalate (DBP) and 2-methylpentane (2-MP) were measured with IR pump and probe (P-P) experiments. The experiments were performed with {approximately}1.5 ps pulses generated by the Stanford superconducting accelerator pumped free electron laser (FEL). Measurements were performed on the Rh(CO){sub 2}(acac) CO asymmetric stretching mode at {lambda} = 4.98{mu}m from 10 K to 300 K. Both the parallel and magic angle probe polarizations decay curves are biexponential over the entire temperature range. The slow component (ranging from 40 ps at 300 K to 55 ps at 10K) is attributed to the population relaxations. For the fast component (ranging from 4-5 ps at 300 K to 13-15 ps at 10K), we propose a mechanism of spectral diffusion, in contrast to the previously proposed ...

1995-12-31

392

Mineralization of phenanthrene and fluoranthene in yardwaste compost  

International Nuclear Information System (INIS)

PAH biomineralization measurements of yardwaste compost samples indicated heterogeneous distribution of active microorganisms and substantial sequestration of the non-polar substrate in the compost matrix. - The purpose of the study was to evaluate the potential of phenanthrene and fluoranthene biodegradation in yardwaste compost materials. These polynuclear aromatic hydrocarbons were chosen for this work because they are relatively readily biodegradable and ubiquitous in the environment. Compost samples were incubated in biometers with "1"4C-labeled phenanthrene and the evolution of "1"4CO_2 was assessed as a measure of mineralization. The "1"4CO_2 evolution varied widely among replicate biometers, possibly as the result of (1) uneven and patchy colonization of phenanthrene-degrading microorganisms on compost particles, and (2) non-uniform dispersion of the labeled substrate spike into the yardwaste microenvironment. Mineralization of phenanthrene reached about ...

2003-07-01

393

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are ...

2004-11-01

394

Panel session: Transport of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)

1987-07-30

395

The pisa experiment: spallation products identified by bragg curve spectroscopy  

International Nuclear Information System (INIS)

In the framework of spallation neutron sources and accelerator-driven systems, the international PISA (Proton-induced Spallation) collaboration has initiated measurements of total- and double-differential cross-sections for products of spallation reactions in a wide range of target nuclei (GU) at the COSY proton accelerator in Julich (Germany). The purpose is to study secondary particle production created in structural, window and target materials via proton beams up to 2.5 GeV of incident kinetic energy. Residual nuclei [H, He up to intermediate mass fragment (IMF)] production cross-sections are of great importance for estimating the damage to target and structure materials involving the planned spallation neutron sources, given that the lifetime of window and target materials is directly associated to those cross-sections. The demand for reliable theoretical predictions on production cross-sections is by no means ...

2004-05-17

396

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have been introduced. To enable the use of a Monte Carlo treatment ...

2007-04-01

397

Design of a closed 4 MW spallation target module with heat removal system for an ADS system  

International Nuclear Information System (INIS)

At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the ...

398

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the detection of highly ...

2006-12-21

399

Vector Boson Scattering in the Standard Model an Overview of Formulae  

CERN Document Server

Tree-level scattering amplitudes of longitudinally polarized electroweak vector bosons in the Standard Model are calculated using Mathematica package Feyncalc. The modifications of low-energy theorems for longitudinally polarized W and Z in the Standard Model are discussed.

1997-01-01

400

The measurement of polarization in backward scattering for the reactions $\\pi^{+} p \\rightarrow p \\pi^{+},K^{+} p \\rightarrow p K^{+}$ and $\\;\\pi^{+} p \\rightarrow \\Sigma^{+} K^{+}$  

CERN Multimedia

The measurement of polarization in backward scattering for the reactions $\\pi^{+} p \\rightarrow p \\pi^{+},K^{+} p \\rightarrow p K^{+}$ and $\\;\\pi^{+} p \\rightarrow \\Sigma^{+} K^{+}$

2006-01-01

401

The Rab GTPase RabA4d Regulates Pollen Tube Tip Growth in Arabidopsis thaliana[W  

UK PubMed Central (United Kingdom)

During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available

2009-02-01

402

Lectin Binding of the Major Polar Tube Protein (PTP1) and its Role in Invasion  

Science.gov (United States)

... 2003)050[0600:LBOTMP]2.0.CO;2 Lectin Binding of the Major Polar Tube Protein (PTP1) ... PTP1. We, therefore, undertook a study ...

403

G?i generates multiple Pins activation states to link cortical polarity and spindle orientation in Drosophila neuroblasts  

UK PubMed Central (United Kingdom)

Drosophila neuroblasts divide asymmetrically by aligning their mitotic spindle with cortical cell polarity to generate distinct sibling cell types. Neuroblasts asymmetrically localize...Full Text Available

2007-09-04

404

Cell Polarity Regulator PARD6B Is Essential for Trophectoderm Formation in the Preimplantation Mouse Embryo1  

UK PubMed Central (United Kingdom)

In preimplantation mouse development, the first cell lineages to be established are the trophectoderm (TE) and inner cell mass. TE possesses epithelial features, including apical-basal cell polarity...Full Text Available

2010-09-01

405

Auxin Transport Is Required for Hypocotyl Elongation in Light-Grown but Not Dark-Grown Arabidopsis1  

UK PubMed Central (United Kingdom)

Many auxin responses are dependent on redistribution and/or polar transport of indoleacetic acid. Polar transport of auxin can be inhibited through the application of phytotropins such as 1-naphthylphthalamic...Full Text Available

1998-02-01

406

Acoustic transducer for acoustic microscopy  

Energy Technology Data Exchange (ETDEWEB)

A shear acoustic transducer-lens system in which a shear polarized piezoelectric material excites shear polarized waves at one end of a buffer rod having a lens at the other end which excites longitudinal waves in a coupling medium by mode conversion at selected locations on the lens.

1990-01-01

407

Thermally cleavable surfactants  

Energy Technology Data Exchange (ETDEWEB)

Two new surfactant molecules are reported which contain thermally labile Diels-Alder adducts connecting the polar and non-polar sections of each molecule. The two surfactants possess identical non-polar dodecyl tail segments but exhibit different polar headgroups. The surfactants become soluble in water when anionic salts are formed through the deprotonation of the surfactant headgroups by the addition of potassium hydroxide. When either surfactant is exposed to temperature above about 60.degree. C., the retro Diels-Alder reaction occurs, yielding hydrophilic and hydrophobic fragments or the aqueous solutions of the surfactants subsequently exhibit loss of all surface-active behavior.

2009-09-29

408

Thermally cleavable surfactants  

Energy Technology Data Exchange (ETDEWEB)

Two new surfactant molecules are reported which contain thermally labile Diels-Alder adducts connecting the polar and non-polar sections of each molecule. The two surfactants possess identical non-polar dodecyl tail segments but exhibit different polar headgroups. The surfactants become soluble in water when anionic salts are formed through the deprotonation of the surfactant headgroups by the addition of potassium hydroxide. When either surfactant is exposed to temperature above about 60.degree. C., the retro Diels-Alder reaction occurs, yielding hydrophilic and hydrophobic fragments or the aqueous solutions of the surfactants subsequently exhibit loss of all surface-active behavior.

2009-11-24

409

Thermally cleavable surfactants  

Energy Technology Data Exchange (ETDEWEB)

Two new surfactant molecules are reported which contain thermally labile Diels-Alder adducts connecting the polar and non-polar sections of each molecule. The two surfactants possess identical non-polar dodecyl tail segments but exhibit different polar headgroups. The surfactants become soluble in water when anionic salts are formed through the deprotonation of the surfactant headgroups by the addition of potassium hydroxide. When either surfactant is exposed to temperature above about 60.degree. C., the retro Diels-Alder reaction occurs, yielding hydrophilic and hydrophobic fragments and the aqueous solutions of the surfactants subsequently exhibit loss of all surface-active behavior.

2006-04-04

410

The structure of the 4.743 MeV state in "8"8Sr  

International Nuclear Information System (INIS)

... states gamma radiation mev range 01-10 photonuclear reactions polarization

412

Physics with Polarized Antiprotons  

Energy Technology Data Exchange (ETDEWEB)

Polarized antiprotons produced by spin filtering with an internal polarized gas target provide access to a wealth of single- and double-spin observables, thereby opening a window to physics uniquely accessible with the HESR at FAIR. This includes a first measurement of the transversity distribution of the valence quarks in the proton, and a first measurement of the moduli and the relative phase of the time-like electric and magnetic form factors G{sub E,M} of the proton. In polarized and unpolarized pp-bar elastic scattering open questions like the contribution from the odd charge-symmetry Landshoff-mechanism at large |t| and spin-effects in the extraction of the forward scattering amplitude at low |t| can be addressed.

2006-04-15

414

Gamma-ray Burst UV/optical afterglow polarimetry as a probe of Quantum Gravity  

CERN Document Server

A possible birefringence effect that arises in quantum gravity leads to a frequency-dependent rotation of the polarization angle of linearly polarized emission from distant sources. Here we use the UV/optical polarization data of the afterglows of GRB 020813 and GRB 021004 to constrain this effect. We find an upper limit on the Gambini & Pulin birefringence parameter $| \\eta | <2\\times 10^{-7}$. This limit is of 3 orders better than the previous limits from observations of AGNs and of the Crab pulsar. Much stronger limits may be obtained by the future observation of polarization of the prompt $\\gamma$-rays.

2007-01-01

415

Enabling Lightwave Electronics with Nanotechnology ...  

Science.gov (United States)

... Acousto-optic programmable dispersive filters (AOPDF) have been developed for optical signal processing, polarization switching in lasers, and ...

2011-03-29

416

Aliens in Antarctica - GCMD - NASA  

Science.gov (United States)

International Polar Year (IPY) Aliens in Antarctica will assess the threat of humans carrying non-native seeds and spores into Antarctica. ...

417

8"+ isomers in N=48 isotones and E2 polarization charges  

International Nuclear Information System (INIS)

... charges energy levels gamma spectra half-life isomeric nuclei kev range

1972-05-01

418

Optimization of shielding for a 60 MeV alpha particle accelerator  

International Nuclear Information System (INIS)

Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.

1988-04-18

419

Accelerated hyperfractionation (AHF) compared to conventional fractionation (CF) in the postoperative radiotherapy of locally advanced head and neck cancer: influence of proliferation  

UK PubMed Central (United Kingdom)

Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available

2002-02-12

420

Combined protection of metals by cathodic polarization and inhibitors  

Energy Technology Data Exchange (ETDEWEB)

A decrease of inhibitor concentration in a medium is always desirable even if the inhibitor is not toxic. In this connection, a sharp increase in the protective effect of certain corrosion inhibitors when cathodic polarization was applied to the metal is reviewed. The importance of a simultaneous account of the chemical structure of inhibitor and the nature of the metal corrosion under cathodic polarization is outlined. Some examples of applying this combined protection of metals are discussed.

1996-12-01

421

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by ...

2004-12-01

422

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system  

CERN Document Server

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system

2010-01-01

423

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project  

CERN Document Server

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project

1961-01-01

424

Accelerator technology program, January-June 1982. Status report  

International Nuclear Information System (INIS)

The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.

425

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

426

Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur  

International Nuclear Information System (INIS)

Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.

427

A connecting coupling  

Energy Technology Data Exchange (ETDEWEB)

The flexible, insulated, single strand cables are electrically connected with a cylindrical polar tip (PN) by means of cylindrical and conical shafts for the polar tips, which enter the faces of the divided, multiwire strand, clamped by tension half couplings. The flat ends of the polar tips being joined are positioned in two concentric mandrel bushings, an internal fixed one and an external, axially movable bushing (PV). The internal bushing is rigidly attached to the end of the left polar tip and equipped with three or four rounded, radial openings, whose diameter is determined by the external diameter of the locking device hinges (ShF) of the connecting couplings. The right polar tip is equipped with an annular channel of trapezoidal section into which the locking device hinges enter. The external movable bushing on the right side has a conical turning and on the left, a ...

1981-06-05

428

Time-Dependent Propagation of High-Energy Laser Beams ...  

Science.gov (United States)

... Law Parameter 28 Summary 28 6. CIRCULAR VS ANNULAR LASER BEAMS 29 7. HIGH-ENERGY LASER BEAM PROPAGATION THROUGH A ...

1977-12-14

429

Target stations and beam dumps for the CERN SPS  

International Nuclear Information System (INIS)

The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.

1977-03-16

431

Luminescence Properties of ScPO{sub 4} Single Crystals  

Energy Technology Data Exchange (ETDEWEB)

Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high temperatures, the band at 4.4 eV is dominant in the x-ray-excited TSL and afterglow spectra. ...

1999-08-16

432

Electroexcitation of the Roper resonance for 1.7 < Q**2 < 4.5 -GeV2 in vec-ep ---> en pi+  

Energy Technology Data Exchange (ETDEWEB)

DOI: http://dx.doi.org/10.1103/PhysRevC.78.045209
The helicity amplitudes of the electroexcitation of the Roper resonance are extracted for 1.7 < Q2 < 4.5 GeV2 from recent high precision JLab-CLAS cross section and longitudinally polarized beam asymmetry data for pi+ electroproduction on protons at W=1.15-1.69 GeV. The analysis is made using two approaches, dispersion relations and a unitary isobar model, which give consistent results. It is found that the transverse helicity amplitude A_{1/2} for the gamma* p -> N(1440)P11 transition, which is large and negative at Q2=0, becomes large and positive at Q2 ~ 2 GeV2, and then drops slowly with Q2. The longitudinal helicity amplitude S_{1/2}, which was previously found from CLAS ep -> eppi0,enpi+ data to be large and positive at Q2=0.4,0.65 GeV2, drops with Q2. Available model predictions for gamma* p -> N(1440)P11 allow us to conclude that these results provide strong ...

2008-10-01

433

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

437

ISR site  

CERN Document Server

A last look at the green field, in the triangular wedge of land stray radiation near the CERN accelerators.

1965-01-01

438

IEE, accelerated waste mgt, McM  

Science.gov (United States)

... in ATCM Recommendation XIV-2. The USAP's materials and waste management efforts are consistent with ...

440

Foreign Affair's: Fool's Gold  

Wastenet

aged gracefully: premature and accelerated corro - sion, erosion, and stress are raising maintenance costs.Last

442

Biophotonics and Bone Biology  

Science.gov (United States)

One of the more-serious side effects of extended space flight is an accelerated bone loss

2004-01-01

443

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge  

Science.gov (United States)

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge

2011-01-01

444

Production of a helium beam in a focused ion beam machine using an electron beam ion trap  

International Nuclear Information System (INIS)

Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.

2007-02-19

445

Low-energy high-current electron beam generation in plasma systems and beam-plasma interaction  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

447

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in ...

1997-06-01

448

Current results from the Texas A and M electron beam ion source  

International Nuclear Information System (INIS)

The electron beam ion source (EBIS) at Texas A and M University was constructed and is currently undergoing tests on the injection and transmission of the electron beam through the solenoid. Results of computer simulation of the electron beam are presented, as well as measurements of electron beam profiles using a pinhole beam analyzer.

449

Beam stability in a 6 GeV synchroton light source  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the effects of motion of beam components (quads, rf cavities and dipoles) on the beam and considers the properties of a compensation system from the perspective of users. The system departs from standard practice in considering active perturbation of the electron beam to verify beam corrections. The effects of local closed orbit perturbations to direct undulator beams at different experimental setups are also considered.

1985-10-01

450

Collective ion acceleration in systems with a virtual cathode  

International Nuclear Information System (INIS)

The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)

2002-11-30

451

Strain enhanced electron spin polarization observed in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements represent the first ...

1991-05-06

452

Carbon dioxide absorption methanol process  

Energy Technology Data Exchange (ETDEWEB)

A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier hydrocarbons from the carbon ...

1987-06-23

453

Carbon dioxide absorption methanol process  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the polar; separating the first stream in a third ...

1989-08-29

454

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam ...

1995-12-31

455

Probing anomalous top-quark couplings induced by dim.6 operators at photon colliders  

International Nuclear Information System (INIS)

Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized #gamma##gamma# colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar#gamma# and #gamma##gamma#H couplings. An optimal-observable analysis for the process #gamma##gamma##->#ttbar#->#l"#+-# was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.

2004-06-21

456

Parity nonconservation in "2"0"7Pb  

International Nuclear Information System (INIS)

Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.

457

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

458

Depolarization in the SLC collider arcs  

Energy Technology Data Exchange (ETDEWEB)

In the 1993 running cycle of the Stanford Linear Collider electron spin polarization measurements with a Moller polarimeter at the end of the linac and a Compton polarimeter near the interaction point (IP) indicated a relative polarization loss of up to 20% across the arc. We present calculations of the depolarizing effects where variations in energy, energy spread and transverse emittance as well as changes in orbit and initial spin orientation are taken into account. We compare our results with measurements and conclude that, in standard operating conditions, the relative polarization loss is only 3+/-2%.

1994-06-27

459

Brazing techniques for side-coupled electron accelerator structures  

Energy Technology Data Exchange (ETDEWEB)

The collaboration between the Los Alamos National Laboratory and the National Bureau of Standards (NBS), started in 1979, has led to the development of an advanced c-w microtron accelerator design. The four 2380-MHz NBS accelerating structures, containing a total of 184 accelerating cavities, have been fabricated and delivered. New fabrication methods, coupled with refinements of hydrogen-furnace brazing techniques described in this paper, allow efficient production of side-coupled structures. Success with the NBS RTM led to Los Alamos efforts on similar 2450-MHz accelerators for the microtron accelerator operated by the Nuclear Physics Department of the University of Illinois. Two accelerators (each with 17 cavities) have been fabricated; in 1986, a 45-cavity accelerator is being fabricated by private industry with some assistance from Los ...

1986-01-01

460

Unsteady MHD micro polar flow and heat transfer over a vertical porous moving plate with variable suction  

Energy Technology Data Exchange (ETDEWEB)

The unsteady two-dimensional laminar flow of a viscous incompressible electrically conducting micro polar fluid via a porous medium past a semi-infinite vertical porous moving plate in the presence of a transverse magnetic field is studied. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micro polar fluid with a suction velocity varying with time. The effects of material parameters on the velocity and temperature fields across the boundary layer are investigated. The method of solution can be applied for small perturbation approximation. Numerical results of velocity and temperature distributions of micro polar fluids are compared with the corresponding flow problems for a Newtonian fluid. (author)

2001-07-01

461

Study of an efficient application of the tagged bremsstrahlung in double-polarization experiments in the GeV range and the use of the inelastic electron scattering under extremely forward angles as alternative to the tagged bremsstrahlung; Studie eines effizienten Einsatzes der markierten Bremsstrahlung bei Doppelpolarisationsexperimenten im GeV-Bereich und der Nutzung der inelastischen Elektronstreuung unter extremen Vorwaertswinkeln als Alternative zur markierten Bremsstrahlung  

Energy Technology Data Exchange (ETDEWEB)

For the preparation of photonic probes for hadron physics the determination of energy and polarization of the photons is essential. In this dissertation in a first part a possibility of the determination of the degree of polarization by use of the asymmetry observables is presented. In a second part a possibility isd discussed to perform an energy and polarization tagging of nearly real photons in electron scattering under small Q{sup 2}. By this method it should be possible to tag billions of photons per second.

2006-03-15

462

Spontaneous radiation from relativistic electrons in a taper undulator. Technical report  

Science.gov (United States)

The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser ...

1983-06-01

463

Search for novel origins of cosmic-ray antiprotons and antimatter with BESS-Polar flight over Antarctica  

Energy Technology Data Exchange (ETDEWEB)

The primary aims of the BESS-Polar program are precise measurements of the low-energy antiproton spectrum and search for cosmologically significant antimatter, which would provide new clues to understand the early Universe. The second flight (BESS-Polar II) over Antarctica was successfully carried out in December 2007 - January 2008. We performed 24.5 days scientific observation just at the solar minimum. The payload worked well during the flight and 4.7 billion cosmic-ray events were collected, which corresponds to 10-20 times statistics of the BESS data taken in the previous solar minimum period (1995 and 1997). Based on the BESS-Polar II data, we will present recent preliminary results of cosmic-ray antiproton measurements and sensitive search for antimatter. (authors)

2010-07-01

464

Progress on polarized target materials with pure carbon background  

Science.gov (United States)

A previous note reviewed methods for the paramagnetic doping of materials for spin-polarized solid targets and some of the history of attempts to apply those methods to hydrocarbons. Since the earlier work on hydrocarbons had yielded, at best, rather mediocre results, that note also speculated on some ways to extend and, possibly, to improve upon the earlier work. The sharpest focus was on the light (number of carbons less than six) alkanes, since these are the hydrocarbons that have the highest hydrogen contents ([approx gt] 17wt %) and therefore require the least degree of polarization to be interesting. This present note summarizes the subsequent work done, to date, exploring some of the issues related to the chemical doping method. The main areas of progress have been in the literature search, experimental results on glass formation by alkanes, and a polarizing test of a prototype'' hydrocarbon.

1993-03-24

465

Progress on polarized target materials with pure carbon background  

Energy Technology Data Exchange (ETDEWEB)

A previous note reviewed methods for the paramagnetic doping of materials for spin-polarized solid targets and some of the history of attempts to apply those methods to hydrocarbons. Since the earlier work on hydrocarbons had yielded, at best, rather mediocre results, that note also speculated on some ways to extend and, possibly, to improve upon the earlier work. The sharpest focus was on the light (number of carbons less than six) alkanes, since these are the hydrocarbons that have the highest hydrogen contents ([approx gt] 17wt %) and therefore require the least degree of polarization to be interesting. This present note summarizes the subsequent work done, to date, exploring some of the issues related to the chemical doping method. The main areas of progress have been in the literature search, experimental results on glass formation by alkanes, and a polarizing test of a prototype'' hydrocarbon.

1993-03-24

466

Progress on polarized target materials with pure carbon background  

Energy Technology Data Exchange (ETDEWEB)

A previous note reviewed methods for the paramagnetic doping of materials for spin-polarized solid targets and some of the history of attempts to apply those methods to hydrocarbons. Since the earlier work on hydrocarbons had yielded, at best, rather mediocre results, that note also speculated on some ways to extend and, possibly, to improve upon the earlier work. The sharpest focus was on the light (number of carbons less than six) alkanes, since these are the hydrocarbons that have the highest hydrogen contents ({approx_gt} 17wt %) and therefore require the least degree of polarization to be interesting. This present note summarizes the subsequent work done, to date, exploring some of the issues related to the chemical doping method. The main areas of progress have been in the literature search, experimental results on glass formation by alkanes, and a polarizing test of a ``prototype`` hydrocarbon.

1993-03-24

467

Observation of strain-enhanced electron-spin polarization in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron-spin polarization in excess of 70% has been observed in photoemission from a 0.1-#mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x#approx#0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single-band transition.

468

Microfluidic local perfusion chambers for the visualization and manipulation of synapses  

UK PubMed Central (United Kingdom)

SummaryThe polarized nature of neurons as well as the size and density of synapses complicates the manipulation and visualization of cell biological processes that control synaptic...Full Text Available

2010-04-15

469

Korea IPY International Trans-Antarctic Scientific Expedition and ...  

Science.gov (United States)

Korea Polar Research Institute (KOPRI) has just ... initiated a program for glaciological activities. This is aimed at establishing infra structure and ...

470

Effect of mass transport on the determination of corrosion rates from polarization measurements  

Energy Technology Data Exchange (ETDEWEB)

Many methods have been proposed for the determination of the corrosion current density from polarization curves; the two most commonly used ones are the three-point method and the curve-fitting method. The basis of these methods is a polarization equation that was derived for the complete absence of mass-transport effect or considers the cathodic partial reaction to be under complete mass-transport control. The mixed-control case has been much less investigated, even though this case may quite frequently reflect practical situations. A completely generalized polarization equation is proposed that can be used as a basis for curve-fitting data evaluation under any conditions. This equation was used to determine the error caused by the neglect of mass-transport effect in conventional data evaluation.

1986-10-01

471

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

472

An efficient quantum secure direct communication scheme with authentication  

Science.gov (United States)

In this paper an efficient quantum secure direct communication (QSDC) scheme with authentication is presented, which is based on quantum entanglement and polarized single photons. The present protocol uses Einstein-Podolsky-Rosen (EPR) pairs and polarized single photons in batches. A particle of the EPR pairs is retained in the sender's station, and the other is transmitted forth and back between the sender and the receiver, similar to the ``ping-pong'' QSDC protocol. According to the shared information beforehand, these two kinds of quantum states are mixed and then transmitted via a quantum channel. The EPR pairs are used to transmit secret messages and the polarized single photons used for authentication and eavesdropping check. Consequently, because of the dual contributions of the polarized single photons, no classical information is needed. The intrinsic efficiency and total efficiency are both 1 ...

2007-07-01

473

Neutron cross-sections on minor actinides for next generation reactors: new data from n_TOF (CERN)  

International Nuclear Information System (INIS)

Full text: Climatic problems associated to the greenhouse effect have recently stimulated a renewed interest in nuclear energy production, and triggered new studies aimed at developing future generation systems that would address current major safety, proliferation and waste concerns. In particular a possible solution to the waste problem could come from transmutation of the highly radiotoxic nuclear waste in Accelerator Driven Systems or in Generation-IV fast nuclear reactors. The design and operation of the new systems require accurate cross-section data on a large number of isotopes, in particular plutonium, minor actinides, long-lived fission fragments and structural materials. An important contribution to the field is being provided since a few years by a new time of-flight facility operative at CERN, n_TOF. The main features of the neutron beam, in particular the wide energy spectrum, ranging from thermal energy to hundreds of MeV, the ...

2008-06-01

474

Transverse velocity modulated e-beam propagating through an undulator as a source of coherent spontaneous radiation  

International Nuclear Information System (INIS)

A new kind of e-beam bunching enabling the production of coherent spontaneous emission (CSE) is proposed and considered. It is shown that an e-beam in passing through an undulator will induce CSE along with incoherent spontaneous radiation on the same wavelength if the e-beam transverse velocity is modulated with a spatial period twice as long as the radiation wavelength. Such angular modulated beams can be regarded as alternatives to conventionally density modulated beams for CSE production. Requirements for e-beams are similar in both cases.

1999-06-01

475

Method and apparatus for efficient photodetachment and purification of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.

2008-02-26

476

Effect of Kerr nonlinearity on an Airy beam  

International Nuclear Information System (INIS)

The effect of Kerr nonlinearity on an Airy beam is investigated by using the nonlinear Schroedinger equation. Based on the moments method, the evolution of the Airy beam width in the rms sense is analytically described. Numerical simulations indicate that the central parts of the major lobe of the Airy beam initially give rise to radial compression during propagation in a focusing medium, even though the rms beam width broadens. The partial collapse of the center parts of the major lobe of the beam appear below the threshold for a global collapse. The evolutions of the field distributions of the Airy beams are different during propagation in different Kerr media while the beams still travel along the parabolic trajectory just as the beam propagates in free space.

2010-10-01

477

Two-gigawatt burst-mode operation of the intense microwave prototype (IMP) free-electron laser (FEL) for the microwave tokamak experiment (MTX)  

Energy Technology Data Exchange (ETDEWEB)

The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the ...

1993-10-06

478

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight techniques with ...

479

Optimization of Cs deposition in the 1/3 scale hydrogen negative ion source for LHD-NBI system  

Energy Technology Data Exchange (ETDEWEB)

A compact cesium deposition system was used for direct deposition of cesium atoms and ions onto the inner surface of the 1/3 scale Hydrogen Negative Ion Source for the LHD-NBI system. A small, well defined amount of cesium deposition in the range of 3-200 mg was tested. Negative ion extraction and acceleration were carried out both in the pure hydrogen operation mode and in the cesium mode. Single Cs deposition of 3-30 mg to the plasma chamber have produced temporary 2-5 times increases of H-yield, but the yield was decreased within several discharge pulses to the previous steady-state value. Two consecutive 30 mg depositions done within a 3-5 hours/60 shot interval, produced a similar temporary increase of H-beam, but reached a larger H-yield steady-state value. Deposition of larger 0.1-0.2 g Cs portions with a 20-120 hours/150-270 shot interval improved the H-yield for a long (2-5 days) period of operation. Directed depositions of Cs to the ...

1999-12-01

480

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. ...

2002-02-01

481

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m"2 could be removed ...

2001-04-08

482

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m{sup 2} could be ...

1997-03-01

483

Exotic nuclear spectroscopy: towards the doubly-magic Sn-100  

International Nuclear Information System (INIS)

Modern nuclear spectroscopy boosts the study of the nuclear matter towards extreme conditions: large excitation energies, high spins, and new nuclear species with unusual ratio between the numbers of neutrons and protons. One of the 'exotic' nuclear regions, practically not studied until now, is the upper part of the N=Z line, from about N#approx#Z#approx#36 to Sn-100, probably the heaviest bound nucleus with N=Z. These nuclei lie close to the proton-drip line. Due to their special composition, it is expected that their study will reveal some phenomena which are less encountered in the nuclei studied till now. In particular, of outstanding interest is the fact that these are the only nuclei which may provide information on the properties of the neutron-proton pairing forces. In spite of its large interest, this nuclear region is exceedingly difficult to reach with the present techniques. The lecture follows the latest results and efforts in the study of the heaviest nuclei with ...

2001-10-18

484

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

485

Activities performed within the program of Nuclear Safety Research on structural and cladding materials for innovative reactor systems able to transmute nuclear waste  

International Nuclear Information System (INIS)

Full text: The transmutation of nuclear waste to reduce the burden on a geological repository is a relevant topic within the Program of Nuclear Safety Research of the Research Centre Karlsruhe. Several studies have confirmed that a high efficiency of transmutation of actinides is reached in fast neutron spectrum reactor system. Therefore, an important effort is dedicated to the study of transmutation strategies with different fast reactors and their associated technologies. Moreover, in international contexts as Generation IV International Forum (GIF) and Sustainable Nuclear Energy Technology Platform (SNETP), fast reactors are considered in the frame of sustainable development of nuclear energy and reduction of waste. The systems that are currently under investigation, in the frame of the different fuel cycle scenarios, are liquid metal cooled and gas cooled fast reactors as well as Accelerator Driven Sub-critical Transmutation devices (ADS). These innovative ...

2009-10-05

486

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for ...

1997-01-05

487

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for ...

1996-09-01

488

(Fast neutron cross section measurements)  

Energy Technology Data Exchange (ETDEWEB)

In the 14 MeV Neutron Laboratory, we have continued the development of a facility that is now the only one of its kind in operation in the United States. We have refined the klystron bunching system described in last year's report to the point that 1.2 nanosecond pulses have been directly measured. We have tested the pulse shape discrimination capability of our primary NE 213 neutron detector. We have converted the RF sweeper section of the beamline to a frequency of 1 MHz to replace the function of the high voltage pulser described in last year's report which proved to be difficult to maintain and unreliable in its operation. We have also overcome several other significant experimental difficulties, including a major problem with a vacuum leak in the main accelerator column. We have completed additional testing to prove the remainder of the generation and measurement systems, but overcoming some of these experimental difficulties has delayed the ...

1991-01-01

489

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

490

Beam position monitor sensitivity for low-[beta] beams  

Energy Technology Data Exchange (ETDEWEB)

Design of a beam position monitor (BPM) which is sensitive to low velo charged particle beams is considered. Quantitative estimates are made for the corrections to the conventional approximations to solutions of the Laplace Equation in two-dimensions when a BPM is used to measure to position of low velocity (low-[beta]) beams. (AIP)

1994-10-10

491

Analytical validation of accelerator mass spectrometry for pharmaceutical development  

UK PubMed Central (United Kingdom)

The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available

2010-03-01

492

Accelerator technology program, January-June 1982. Status report  

Science.gov (United States)

The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.

1983-12-01

493

Accelerated surgical stay programs. A mechanism to reduce health care costs.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To increase cost-efficiency while maintaining the standard of medical care, an accelerated surgical stay program for patients having breast surgery was instituted. SUMMARY BACKGROUND DATA:...Full Text Available

1994-04-01