Abstract Objective: The aim of this investigation was to compare the healing of laser-irradiated and non-irradiated wounds covered by an occlusive dressing in mice. Background data: Many previous studies of the effects of laser irradiation of experimental wounds in mice and rats did not cover the wounds so that healing occurred mainly by contraction. Healing of covered wounds is slower and mimics more closely woundhealing in humans. Materials and Methods: Forty-seven diabetic and twenty non-diabetic mice were used. A single wound (5?mm diameter) was created on the left flank of each animal and covered by Tegaderm HP dressing (Day 1). Wounds were irradiated (660?nm) for 20?s using a lower power (18?mW) or higher power (80?mW) laser starting immediately ...
The inflammatory process has direct effects on normal and abnormal woundhealing. Hypertrophic scar formation is an aberrant form of woundhealing and is an indication of an exaggerated function of...Full Text Available
Aim:The effect of Tualang honey on woundhealing in bacterial contaminated full-thickness burn wounds was evaluated in 36 male Sprague Dawley rats.Materials...Full Text Available
Integumentary wounds in mammalian fetuses heal without scar; this scarless woundhealing is intrinsic to fetal tissues and is notable for absence of the contraction seen in postnatal (adult) wounds....Full Text Available
Studies in our wound ballistics laboratory have shown that excellent healing can occur in complicated assault rifle wounds that are free of tension and well drained. A conservative approach to debridement and excision of tissue in uncomplicated extremity wounds may be a valid and resource-saving technique. PMID:2366941
BackgroundDespite numerous treatments available for deteriorated cutaneous woundhealing such as a diabetic foot, there is still the need for more effective therapy. Adipose-derived...Full Text Available
BackgroundOne-stage implant placement has clinically acceptable treatment outcomes. Among other advantages, it may allow investigation of early woundhealing. The...Full Text Available
Abstract Objectives: This investigation reviewed experimental studies of laser irradiation of woundhealing in mice and rats published from 2003 to August 2008, respectively, to assess putative stimulatory effects of this treatment. Background: Animal models, including rodents, attempt to reflect human woundhealing and associated problems such as dehiscence, ischemia, ulceration, infection, and scarring. They have played a key role in furthering understanding of underlying mechanisms involved in impaired woundhealing, and in testing new therapeutic strategies including laser irradiation. Method: Original research papers investigating effects of laser or monochromatic light therapy on woundhealing in mice and rats and published from January 2003 to August 2008 were retrieved from library...
Retaining an appropriate level of moisture at the interface between a healingwound and an applied dressing is considered to be critical for effective woundhealing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time.A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate f...
The aim of this study was to observe both the clinical signs and symptoms of wounds at risk of infection, that is critically colonised (biofilm infected) and antimicrobial-performance of an ionic silver alginate/carboxymethylcellulose (SACMC) dressing, in comparison with a non silver calcium alginate fibre (AF) dressing, on chronic venous leg and pressure ulcers. Thirty-six patients with venous or pressure ulcers, considered clinically to be critically colonised (biofilm infected), were randomly chosen to receive either an SACMC dressing or a non silver calcium AF dressing. The efficacy of each wound dressing was evaluated over a 4-week period. The primary study endpoints were prevention of infection and progression to woundhealing. The SACMC group showed a statistically significant (P = 0.017) improvement to healing as indicated by a reduction in the surface area of the ...
The aim of this study was to observe both the clinical signs and symptoms of wounds at risk of infection, that is critically colonised (biofilm infected) and antimicrobial-performance of an ionic silver alginate/carboxymethylcellulose (SACMC) dressing, in comparison with a non silver calcium alginate fibre (AF) dressing, on chronic venous leg and pressure ulcers. Thirty-six patients with venous or pressure ulcers, considered clinically to be critically colonised (biofilm infected), were randomly chosen to receive either an SACMC dressing or a non silver calcium AF dressing. The efficacy of each wound dressing was evaluated over a 4-week period. The primary study endpoints were prevention of infection and progression to woundhealing. The SACMC group showed a statistically significant (P = ...
The interactions between biochemical processes and mechanical signaling play important roles during various cellular processes such as woundhealing, embryogenesis, metastasis, and cell migration. While...Full Text Available
Deficient woundhealing in diabetic patients is very frequent, but the cellular and molecular causes are poorly defined. In this study, we evaluate the hypothesis that high glucose concentrations inhibit...Full Text Available
Accumulation of molecular damage and increased molecular heterogeneity are hallmarks of cellular aging. Mild stress-induced hormesis can be an effective way for reducing the accumulation of molecular...Full Text Available
AbstractThree biologic dressings [split-thickness allogeneic skin (STS)], allogeneic peritoneum (P), and xenogenic porcine small intestinal submucosa (PSIS)] were...Full Text Available
Excess caveolin-1 has been reported to play a role in age-dependent hyporesponsiveness to growth factors in vitro. Therefore, we hypothesized that caveolin-1–dependent hyporesponsiveness...Full Text Available
Bacterial cellulose was produced by Acetobacter xylinum (strain TISTR 975). Bacterial cellulose is an interesting material for using as a wound dressing since it provides moist environment to a wound resulting in a better woundhealing. However, bacterial cellulose itself has no antimicrobial activity to prevent wound infection. To achieve antimicrobial activity, silver nanoparticles were impregnated into bacterial cellulose by immersing bacterial cellulose in silver nitrate solution. Sodium borohydride was then used to reduce the absorbed silver ion (Ag+) inside of bacterial cellulose to the metallic silver nanoparticles (Ag0). Silver nanoparticles displayed the optical absorption band around 420nm. The red-shift and broadening of the optical absorption band was observed when the mole rat...
Abuzakuk T, Coward P, Shenava Y, Kumar VS, Skinner JA. The management of wounds following primary lower limb arthroplasty: a prospective, randomised study comparing hydrofibre and central pad dressings. Abstract Wound care following lower limb arthroplasty has not been subject to in-depth clinical research, primarily because such wounds usually heal without complication. However, when prosthetic implants are used, serious wound problems can be disastrous (Whitehouse et al. Infect Control Hosp Epidemiol 2002;23:183-9; Lindwell OM. Clin Orthop Relat Res 1986;211:91-103). We report the results of a prospective, randomised, controlled trial comparing a hydrofibre (Aquacel) and central pad (Mepore) dressing in the management of acute wounds following primary total hip or knee arthroplasty left ...
Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healingwound than in the surrounding cornea.
Abstract: We tested the effects on the early-stage woundhealing of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) nanofiber matrices cultured with hair follicular cells. PHBV only, PHBV/collagen, and PHBV/gelatin at a 7/3 weight ratio were produced by electrospinning, and their in vitro cell culture and in vivo woundhealing as biological dressings were examined. In cell attachment and growth on matrices, dermal sheath (DS) cells attached to hydrophilic PHBV/collagen and PHBV/gelatin faster than hydrophobic PHBV at the early incubation stage (up to 6 h). From 6- to 24-h incubation, PHBV/collagen showed the best results in cell culture. Furthermore, PHBV/collagen cocultured for 3-5 days with DS and epithelial outer root sheath (ORS) cells expressed more extracellular materials, such a...
Abstract Purpose: We investigated the effects of various rinsing and healing protocols on corneal wound repair and inflammation following alkali burn in rabbits. Methods: We conducted in vitro, in vivo and ex vivo studies. First, different rinse solutions were tested in vitro after incubation of ocular cells with methanol or NaOH. Cell viability was then assessed using the neutral red test (cytofluorometry). Second, NaOH was applied to rabbit corneas and associations of rinse solutions (NaCl 0.9% or controlled ionization marine solutions) with N-acetylcysteine or vegetable oils (from Calophyllum inophyllum and Aleurites moluccana) were tested in vivo. The regeneration of the corneal epithelium and the infiltration of inflammatory cells were evaluated using in vivo confocal microscopy and e...
A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in woundhealing.
Recent advances in cell culture technology permit the generation of large stratified epithelial sheets appropriate for wound coverage. Autografts (sheets prepared from the patient's own skin) have proven life-saving in the treatment of large third-degree burns and have been successfully employed in the management of chronic ulcers. Allografts (sheets prepared from the skin of an unrelated donor) have also been used. In our experience, cultured allografts derived from neonatal foreskin provide a potent stimulus to healing in a variety of partial thickness wounds. Their application is a simple outpatient procedure which involves no discomfort for the patient. In contrast to autografting, no biopsy is necessary and use of cultured allogenic cells permits immediate grafts availability and possibility of stockpiling and preserving grafts for future use. Preparation of epithelial sheets suitable for grafting is also faster and ...
Non-thermal (low-temperature) physical plasma is under intensive study as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. The purpose of this study was to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma and to measure the effectiveness of plasma treatments against bacteria in biofilms and on wound surfaces. Overall, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, Burkholderia cenocepacia and Escherichia coli, there were no survivors among the initial 10(5) c.f.u. after a 5 min plasma treatment. The susceptibility of Gram-positive bacteria was species- and strain-specific. Streptococcus pyogenes was the most resistant with 17?% survival of the initial 10(5) c.f.u. after a 5 min plasma ...
Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.
The surgical management of osteoradionecrosis of the temporal bone has met with limited success because of the difficulty in accurate assessment of the viability of nonnecrotic bone intraoperatively. Failure to resect all nonviable bone results in recurrence of a necrotic focus. With the use of hyperbaric oxygen therapy to stabilize marginal bone and oral tetracycline to label viable bone preoperatively, removal of all nonviable bone can be accomplished. Postoperatively, a second course of hyperbaric therapy enhances woundhealing, thus assuring a successful outcome. This article details a successful systematic approach that was developed to resect a necrotic focus in the temporal bone of a 10-year-old boy who had undergone a full course of radiotherapy for treatment of a rhabdomyosarcoma.
Purpose. To examine the impact of residual limb osteomyelitis (RLO) on the rehabilitation of lower limb amputees. Method. Retrospective review of the casenotes of patients with RLO. Information sought included details of amputation, clinical features of investigations for and management of RLO and its effect on rehabilitation. Results. There were seven transfemoral and three transtibial amputees. Indications for amputation were vascular disease in nine cases, trauma in one. In each case, delayed woundhealing or residual limb pain prompted radiological, hematological and microbiological investigations. Average time between amputation and diagnosis was 187 days. One patient died before treatment commenced. Two transtibial amputees were treated with intravenous antibiotics while rehabilitati...
Despite a complex cascade of cellular events to reconstruct the damaged extracellular matrix, ligament healing results in a mechanically inferior scarred ligament. During normal healing, granulation...Full Text Available
In order to verify long-term reliability of amorphous alloy wound core distribution transformers, accelerated aging tests and field trials used by actual transformers were practiced. As for accelerated aging tests, short-circuit tests were added to imitate mechanical stress in operation on a utility's distribution system. As a result, even after the equivalent of 30 years, which was the normal expected transformer's life, magnetic characteristic was unchanged, so these transformers could be operated. Also, about field trials, two hundred transformers of four kinds were installed on a utility's distribution system to look into no-load characteristics. They were equipped with a mechanism to measure load current, background vibration and lightning surge current, so the influence for magnetic characteristic could be inspected. As a result, remarkable change wasn't seen even after six months.
Most papers appearing in the surgical literature dealing with wound ballistics concern themselves with wound management in the civilian setting. The pathophysiology of modern war wounds is contrasted with ballistic wounds commonly encountered in peacetime, but it should be noted that even in peacetime the modern terrorist may have access to sophisticated military weaponry, and that patients injured by them may fall within the catchment area of any civilian hospital. Management problems associated with both wound types are highlighted; areas of controversy are discussed. The orthodox military surgical approach to ballistic wounds is expounded and defended. PMID:1996857
Background Fracture healing in osteoporosis is delayed. Quality and speed of fracture healing in osteoporotic fractures are crucial with regard to the outcome of patients. The question arises whether established antiosteoporotic drugs can further improve fracture healing. Materials and methods Osteoporosis manifests predominantly in the metaphyseal bone. Nevertheless, an established metaphyseal fracture model is lacking. A standardized metaphyseal fracture-healing model with stable plate fixation was developed for rat tibiae. The healing process was analyzed by biomechanical, gene expression, and histomorphometric methods in ovariectomized (OVX) and sham-operated rats (SHAM), compared to standardized estrogen (E)- and raloxifene (R)-supplemented diets. Results Estrogen and raloxifene impro...
PurposeWound infection after an ileostomy reversal is a common problem. To reduce wound-related complications, purse-string skin closure was introduced as an alternative to conventional...Full Text Available
Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low rates of pathologic complete remission have ...
Thin, elastic foils of good resistance to the air exposure, patented as woundhealing aids, were prepared by evaporation of a blend of lecithin (L) and sodium hyaluronan (H) taken under varying proportions. The contact angle for water, glycerol, formamide, ethylene glycol and diiodomethane, was determined for these foils. The contact angle was correlated against the H:L foil composition. For all liquids but formamide the highest contact angle was noted for the H:L = 2:1 (g g{sup -1}) ratio. The contact angles provided estimation of the work of adhesion. At the same L:H ratio the work of adhesion was the lowest. It was suggested that lecithin cross-linked hyaluronan. Since the work of adhesion of the studied liquids was similar to that of diiodomethane, it could be concluded that almost all functional groups on the foil surface were completely blocked. Perhaps, at H:L = 2:1 (g g{sup -1}) a stoichiometric complex of hyaluronic acid with lecithin ...
Greenman J, Thorn RMS, Saad S, Austin AJ. In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings. Int Wound J 2006;3:322-329. Abstract The aim of this study was to develop an in vitro wound infection model that allows the comparison of the bacterial kill rate of antimicrobial wound dressings over the course of 3 days, with renewed microbial challenges each day, under realistic wound-like conditions. A test bed model of a moderately exuding wound was constructed from a hydrogel containing releasable foetal calf serum (FCS), and cellulose discs dosed with test microbes (Methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) suspended in 50% FCS applied at the interface between the test dressing and the hydrogel test bed. Freshly prep...
I review the past and present of wound ballistics research in China and look toward the future of this subject. The main points area as follows: (1) Before the 1970s, China did not conduct any experimental study on wound ballistics. (2) After the 1970s, experts in ordnance and medicine closely cooperated to conduct a series of experiments or tests on wound ballistics, such as wounding effects and the mechanism of various high-speed projectiles, the treatment of the protection from firearm wounds, high quality of ammunition design, lethality criterion, blast injuries, etc. Between 1981 and 1993, four national symposia on wound ballistics were held in China. In 1988, China sponsored the Sixth International Symposium on wound Ballistics. China has made great contributions to this subject. (3) As for the future of Chinese research on ...
In 18 piglets, weighing 10-15 kg, third-degree burns or full-thickness skin excisions of 4 X 4 cm were inflicted. The effect of five dressing materials on adhesiveness to the wounds, appearance, conformability, wound contraction, bacterial count, and morphology of the wound was studied at the end of the seventh and fourteenth days without dressing changes. In 11 piglets with a burn wound, the most adherent dressing was collagen sponge(CS), followed by polyurethane sponge (PU), pigskin xenograph (PS), and xeroform. CS more effectively debrided the wound from coagulated necrotic tissue than the other dressings. Wound contraction was maximal with CS dressing (52%), followed by PU (44%), xeroform (32%), and PS (27%). In another seven piglets with full-thickness excised wounds, a velour dressing made of polytetrafluoroethylene (PTFE) or PU ...
OBJECTIVE: We studied 22 dogs to examine the effect of basic fibroblast growth factor (bFGF) alone, in comparison with omental or muscular wrapping on airway healing in a tracheal autotransplantation...Full Text Available
Cimetidine 1 g daily is often continued for a fixed period beyond the time of healing of duodenal ulcer on the assumption that it might reduce the subsequent relapse rate. To test this, 194 patients...Full Text Available
The knowledge of wound ballistics and of wounding mechanisms is mandatory for the radiologist to interpret the CT findings of gunshot wounds. The severity of a bullet wound depends on the characteristics of the tissue it goes through, i.e., tissue elasticity, density, thickness of the wounded body part, the type of tissue, its specific gravity, internal cohesiveness and anatomical relationships, as well as on missile characteristics, i.e., mass, shape, fragmentation and deformation. Bullet velocity is certainly a major factor in wounding, but it is only one factor. Two major wounding mechanisms exist the crushing of the bullet-struck tissue (forming the permanent cavity) and radial stretching (forming a temporary cavity). Bullet "yaw" is defined as the angle between the long axis of the bullet and its flight path. The yaw is directly ...
This paper reports the characteristics and local management of 826 acute wounds identified during an audit across all health care providers serving the population of Bradford, UK. Of the wounds encountered 303 were traumatic wounds and 237 primary closures with smaller numbers of other acute wound types. Of the 303 traumatic wounds 174 occurred in women (57.4%). Men predominated in the under 45s (65M:26F), this being largely accounted for by hand and finger trauma (n=62) particularly in patients of working age (M32:F12). Women predominated in the over 65s (50M:130F), this being largely accounted for by lower limb traumatic wounds (M24:F91), the majority of these being in patients 65 and over (M14:F82). In this sub-group of 96 patients 25 had wounds of 6 weeks or longer duration, only 3 had...
Abstract Silver-impregnated wound dressings continue to be routinely used for the management of infected wounds, or wounds that are at risk of becoming infected. The ability of antimicrobials that have been incorporated into wound dressings to kill microorganisms within the dressing requires appropriate evaluation using in vitro models. In vitro models that have been exploited for this purpose have included the corrected zone of inhibition and the log reduction assay. However, these and other related culturable-based assays are purported to have poor correlation with the overall microbicidal barrier activity of an antimicrobial wound dressing. This is because culturable-based methods only retrospectively indicate bacterial cell death and do not take into account viable but nonculturable st...
We have previously observed that auxin can act as a repressor of the wound-inducible activation of a chimeric potato proteinase inhibitor II-CAT chimeric gene (pin2-CAT) in transgenic...Full Text Available
OBJECTIVE: The management and outcome of 138 abdominal shotgun wounds were examined over a 5-year period. SUMMARY BACKGROUND DATA: It has been proposed that exploratory laparotomy may be unnecessary...Full Text Available
Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, ...
The main objective of Phase I of this SBIR project was to demonstrate the feasibility for successful development of an antimicrobial wound dressing based on a hydrogel sustained release matrix. This goal has been achieved. In vitro studies of drug diffusi...
US Army casualty deaths in the Republic of Vietnam were analyzed to provide information on wound ballistics that may be used by interested branches of the services on the subjects of casualty reduction, wounding, mechanisms, and evaluation of hostile weap...
Instrumentation, equipment, and space requirements are outlined which would satisfy a portion of the needs of the Wound Ballistics Program of research into the terminal behavior of missiles from a variety of antipersonnel munitions (fragments, flechettes,...
The clinical manifestation of wounds of the heart is determined by the mode, site and size of the injury as well as the structure of the pericardial and myocardial lesion. Diagnosis can be confirmed by ECG and echocardiography. Only 20% of the patients with penetrating wounds of the heart live for more than 30 minutes. Pericardio-centesis should be used only to gain time for a safe sternotomy, cardiac decompression and suture of the wound of the heart. An aggressive surgical approach is mandatory. Cardiopulmonary bypass is necessary only to correct of concomitant lesions. PMID:1983618
Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound ...
Wound dressings impregnated with silver have a role to play in aiding to reduce both the dressing and wound microbial bioburden. It is therefore imperative that antimicrobial wound dressings have efficacy on a broad range of clinical significant microorganisms. Accordingly, this study aimed to determine the antimicrobial efficacy of a silver alginate dressing against 115 wound isolates that had been isolated routinely from patients at West Virginia University Hospital. Standardised corrected zones of inhibition (CZOIs) were performed on all clinical isolates. It was found that the silver alginate dressing was able to inhibit the growth of all microorganisms tested. In particular, the silver alginate dressing inhibited the growth of Candida albicans and yeasts with CZOI of 3-115 mm. All met...
The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary excretion patterns for ...
This paper presents the concept of a biological inspired reconfigurable hardware cell architecture which supports self-organisation and self-healing. Two fundamental processes in biology, namely fertilization-to-birth and cell self-healing have inspired the development of this cell architecture. In biology as well as in our hardware cell architecture it is the DNA which enables these processes. We propose a platform based on the electronic DNA (eDNA) and show through simulation, its capabilities as a new generation of robust reconfigurable hardware platforms. We have created a Java based simulator to simulate our self-organisation and self-healing algorithms and the results obtained from this looks promising.
BackgroundThe routine removal of orthopaedic fixation devices after fracture healing remains an issue of debate. There are no evidence-based guidelines on this matter, and little...Full Text Available
AimsTo assess whether frequency of placebo administration is associated with duodenal ulcer healing.MethodsA systematic literature...Full Text Available
Osteoporosis is accompanied by predominantly metaphyseal fractures with a delayed and qualitatively reduced healing process. This study addressed the question of whether fracture healing in the context of osteoporosis prophylaxis is improved with estrogen (E) or alendronate (ALN). Thirty-six ovariectomized and 12 sham-operated 12-week-old rats received soy-free (osteoporotic C, sham), E-, or ALN- supplemented diets. After 10?weeks, a metaphyseal tibia osteotomy and standardized T-plate fixation were performed. After a 5-week healing process, the fracture callus was evaluated qualitatively by biomechanical bending test and quantitatively in microradiographic sections. The time course of callus formation was examined using fluorochrome-labeled histological sections. Administration of E impro...
Abstract The healing of predominantly metaphyseal fractures in postmenopausal osteoporosis is delayed and comparatively poor. Due to the potential side effects of HRT, natural alternatives are appealing. The aim of this study was to determine whether Cimicifuga racemosa extract BNO 1055 improves metaphyseal fracture healing in severe osteopenic bone in rats. Thirty three 12 week old female rats developed severe osteopenia during 10 weeks after ovariectomy. After metaphyseal tibial osteotomy and standardized T plate osteosynthesis, the healing periods in ovariectomized rats (C), 17 estradiol (E) and Cimicifuga racemosa (CR) supplemented diets were assessed for 35 days. Changes in callus morphology were evaluated qualitatively by biomechanical testing and quantitatively in microradiographies...
Chinese and Chumash traditional medical approaches are similar in terms of disease causation, use of acupuncture or healing touch, plants, spiritual and philosophical approaches. This article provides...Full Text Available
Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)
A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with /sup 99m/Technetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio less than or equal to 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude ...
A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with "9"9"mTechnetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio #<=# 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude that "9"9"mTc-MDP ...
Initial CT grading of renal injury was correlated with the frequency of complications and the time course of healing in 35 children. All renal contusions (grade 1, 8) and small parenchymal lacerations (grade 2, 8) healed without complications. All lacerations extending to the collecting system (grade 3, 9) resulted in mild to severe loss of renal function with progressive healing over 4 months. One of four segmental infarcts (grade 4 A), and five of six vascular pedicle injuries (grade 4 B) resulted in severe loss of renal function. Complications, including urinoma (2), sepsis (1), hydronephrosis (1), and persistent hypertension (2), were limited to grade 3 and 4 injuries. Our results suggest that mild renal injuries do not require follow-up imaging. Major renal lacerations and vascular pedicle injuries, however, often result in loss of renal function and should be followed up closely due to the risk of delayed ...
The aim of our experiment was the testing of effects of common ammunition on usable and slightly accessible biological tissue thereby to create fundamental simple biological model for trials of wounded ballistic. Like objective tissue was elected biological material - pork and beef hind-limbs, pork head, pork bodily cavity. It was discovered that objective tissue is able to react to singles types of shots in all spectrum results namely simple smooth penetration wound as well as splintery fracture in dependence on kind of using ammunition. Pork hind-limb was evaluated like the most suitable biological material for given object. PMID:17172163
Objective Comorbidities predisposing cardiac surgical patients toward deep sternal wound infection, such as diabetes and obesity, are rising in the United States. Longitudinal analysis of risk factors, morbidity, and mortality was performed to assessed effects of these health trends on deep sternal wound infection rates. Methods In this retrospective analysis of all median sternotomies performed at a single institution from 1991 through 2006, demographic and surgical characteristics were identified from a prospective database. The cohort was separated into periods from 1992 through 2001 and 2002 through 2006 to identify longitudinal trends in risk factors for deep sternal wound infection. Univariate and matched multivariable analyses were performed. Results Overall, study population had in...
Purpose:This study investigated the penetration of lidocaine around and through a sutured incision following the application of iontophoretic and passive patches...Full Text Available
The purpose of this study was to compare the clinical outcomes and wound complications in coccygectomy with or without subperiosteal resection. This retrospective study included 25 patients who underwent...Full Text Available
ABSTRACT To date the effect of silver-containing wound dressings on biofilms, known to be present in chronic wounds, has not been determined or documented. In this current study, we aimed to determine the antimicrobial effect of a silver-containing dressing on biofilms grown in a chambered slide model. Before the addition of a wound dressing onto a 24-hour biofilm, composed of either Pseudomonas aeruginosa, Enterobacter cloacae, Staphylococcus aureus, or a mixed bacterial community, a fluorescent dye was applied. This enabled the viability of sessile bacteria to be monitored in real-time, using a rapid form of confocal laser scanning microscopy over a contact time period of 48 hours. By analyzing all the three-dimensional data generated from the confocal time-lapse sequences, 90% of all se...
Two kinds of Si3N4/SiC composite ceramics having different sintering auxiliaries were fabricated to investigate reproduction of crack healing phenomenon, effects of sintering auxiliaries on crack healing behavior, optimal crack healing conditions, and high-temperature strength characteristics of crack healed portions. The experiment used sinters added with SiC powder at 20% by volume, and hot-pressed under conditions of a sintering temperature of 1850 degC, time for two hours, and a pressure of 35 MPa. The sintering auxiliaries used are Y2O3 and Al2O3. In the experiment, pre-cracks were introduced into test specimens, and heat treatments were given in atmosphere and in argon gas atmosphere at 1300 degC for one hour. A four-point bending test was conducted in atmosphere as a strength test. The result of the experiment revealed that the materials which were heat-treated in atmosphere have greater crack ...
Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.
ABSTRACT Purpose: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. Material and Methods: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations i...
Mechanobiological theories have been introduced to illustrate the interaction between biology and the local mechanical environment during bone healing. Although several theories have been proposed, a quantitative validation using histomorphometric data is still missing. In this study, in vivo histological data based on an ovine animal experiment was quantified and used to validate bone healing simulations focussing on the endochondral ossification process. The bone formation at different callus regions (periosteal and endosteal bone at the medial and lateral side) was analyzed from in vivo data and quantitatively compared with in silico results. A histomorphometric difference was found in medial and lateral hard callus formation 3 weeks after osteotomy. However, the same amount of new bone...
(E)-α-Bisabolene synthase is one of two wound-inducible sesquiterpene synthases of grand fir (Abies grandis), and the olefin product of this cyclization reaction...Full Text Available
Tomato (Lycopersicon esculentum var. Better Boy) plants were transformed with a tomato leaf wound-inducible polygalacturonase (PG) β-subunit gene in the antisense orientation...Full Text Available
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...
In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The ...
The World Health Organization (WHO) estimates that as many as 80% of the world's more than six billion people rely primarily on animal and plant-based medicines. The healing of human ailments by using...Full Text Available
Osterix (Osx) is a zinc-finger-containing transcription factor that is expressed in osteoblasts of all endochondral and membranous bones. In Osx null ...Full Text Available
BackgroundDifferences in duration of bone healing in various parts of the human skeleton are common experience for orthopaedic surgeons. The reason for these differences is not obvious...Full Text Available
Background:The present study measured longitudinal changes in bone turnover markers in elderly patients with vertebral fracture and investigated the relationship among bone turnover...Full Text Available
We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)
A solid electrolytic capacitor having a solid electrolyte comprising manganese dioxide dispersed in an aromatic polyamide capable of further cure to form polyimide linkages, the solid electrolyte being disposed between a first electrode made of valve metal covered by an anodic oxide film and a second electrode opposite the first electrode. The electrolyte autogenously produces water, oxygen, and hydroxyl groups which act as healing substances and is not itself produced pyrolytically. Reduction of the manganese dioxide and the water molecules released by formation of imide linkages result in substantially improved self-healing of anodic dielectric layer defects.
The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.
... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...
Growing evidence suggests the Wnt family of secreted glycoproteins and their associated signaling pathways, linked to development, are recapitulated during wound repair and regeneration events. However,...Full Text Available
The growth regulating factor CTGF/CCN-2 is an integral factor in growth and development, connective tissue maintenance, wound repair and cell cycle regulation. It has recently been reported that CTGF/CCN-2...Full Text Available
BackgroundMedian sternotomy infection and bony nonunion are two commonly described complications which occur in 0.4 - 5.1% of cardiac procedures. Although relatively infrequent,...Full Text Available
... Previous Topic Pain Next Topic Scars and wounds Prostheses Prostheses (pross-THEE-sees) are man-made substitutes ... covered by medical insurance (this includes wigs). Breast prostheses: Contact your local chapter of the American Cancer ...
Beginning in 1990, gram-positive rods resembling Actinomyces pyogenes were found with increasing frequency in mixed cultures from various infectious processes, most of them from patients with otitis,...Full Text Available
Ballistics involves the study of the scientific properties of projectiles, their behavior and their terminal effects on biological tissues and other materials. Wound ballistics deals with the analysis of injuries caused by projectiles and the behavior of projectiles within human or other biological tissues. The nineteenth century witnessed the development of both of these areas with Kocher's hydrodynamic theory and the understanding of the significance of bullet deformation in causing tissue injury. The degree of traumatic disruption of tissues and organs was also related to direct energy transfer from projectiles. While subsequent research has concentrated on elucidating further mechanisms of injury, the exact cause of remote tissue damage from high energy projectiles is still the subject of ongoing research. Much of the contemporary literature regarding wound ballistics concentrates on the forensic aspects and their application for legal ...
This Military Working Dog (MWD) was shot in the chest during combat operations in Iraq. Military Working Dogs are critical to the safety and well- being of deployed troops in combat operations and, as such, they are triaged and treated in our combat hospi...
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.
The NCRP Wound Model, which describes the retention of selected radionuclides at the site of a contaminated wound and their uptake into the transfer compartment, has been combined with the ICRP element-specific systemic models for those radionuclides to derive dose coefficients for intakes via contaminated wounds. These coefficients can be used to generate derived regulatory guidance (i.e., the activity in a wound that would result in an effective dose of 20 or 50 mSv, or in some cases, a organ-equivalent dose of 500 mSv) and clinical decision guidance (i.e., activity levels that would indicate the need for consideration of medical intervention to remove activity from the wound site, administration of decorporation therapy or both). Data are provided for 38 radionuclides commonly encountered in various activities such as nuclear weapons, fuel fabrication or recycling, waste ...
In an earlier publication we considered acceleration of plasma rings (Compact Torus). Several possible accelerator configurations were suggested and the possibility of focusing the accelerated rings was discussed. In this paper we consider one scheme, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focusing) during acceleration. Because the allowable acceleration force, F/sub a/ = kappaU/sub m//R where (kappa < 1), increases as R/sup -2/, the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case, however, since the accelerating flux can expand as the ring ...
A scintimetric study using Tc-99m MDP was made of 54 patients with delayed union, nonunion, or late segmental collapse of the femoral head, 4-92 months after femoral neck fracture. In radiographically verified collapse, the radionuclide uptake ratio between the femoral head on the fractured and on the intact side (HHR) was significantly higher than in fractures resulting in delayed union or nonunion. On the basis of scintimetric and radiographic findings, the patients with healing disturbances could be divided into three groups, characterized by the following features: (1) Satisfactory post-reduction position of the fracture without subsequent redisplacement and a high HHR, which as a rule turned out to be delayed union; (2) The same radiographic pattern but with a lower HHR, which in most cases resulted in nonunion; (3) Inadequate reduction or early redisplacement of the fracture with a high HHR, which resulted in nonunion. The fractional precision in ...
Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or _9_9 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the ...
Forty-five patients with recent cervical hip fractures were included in a prospective, clinical, radiographic and sequential scintimetric study. Striking changes in radionuclide uptake over the entire hip region on the fracture side were found during the first 5 postoperative months. Fractures that healed without complications showed the highest relative femoral head uptake at 1 week and a peak value at 6 weeks, followed by a gradual decline at the subsequent examinations. Fractures with complications (redisplacement, nonunion, or late segmental collapse) showed a lower initial uptake and a more gradual increase and only a slight tendency towards increased uptake after 3 months. The accuracy in predicting nonunion with scintimetric examination alone is high both at 1 and at 6 weeks, and the accuracy is almost equally high with combined scintimetric, radiographic, and clinical assessment 3-5 months postoperatively.
Desiccation cracking is a common phenomenon in clay materials, which may considerably increase the hydraulic conductivity of soil. This issue is one of the main concerns in the design and construction of landfill covers, especially, in arid regions. For some highly plastic soils, permeability increases during cyclic drying and wetting are not significant, even though cracking may clearly be noticed in the soil. These cracks may self-heal during subsequent wetting and saturation processes. In the present study, large scale experimental models of various natural clayey soils with various plasticity indices were subjected to cyclic drying and wetting and hydraulic conductivity testing to better understand cracking behaviour and self-healing in fine-grained soils. The soils are candidate clay ...
Purpose The aim of this study was to evaluate the role of host periosteum and recipient bed perforation on the healing of an onlay graft to the mandible based on histologic and immunohistochemical analysis. Materials and methods Each of the 12 adult sheep used in the study received four iliac corticocancellous onlay bone grafts on the lateral surface of the mandible. In experiment 1, the block graft was placed in direct contact with the recipient bed and fixed with micro-screws, and in experiment 2, the recipient cortical bed was perforated before graft placement. The host periosteum around the graft was excised before flap replacement in experiment 3, and in experiment 4, a sheet of silicone membrane was placed between the graft and the recipient bed. The animals were euthanised at 4, 8, ...
The objective of this study was to evaluate the role of collagen membrane and Bio-Oss coverage in healing of an onlay graft to the mandible. Twelve adult sheep each received an onlay bone graft (experiment 1), bone graft+Bio-Gide (experiment 2), and bone graft+Bio-Oss/Bio-Gide (experiment 3) on the lateral surface of the mandible. The animals were euthanized at 4, 8, 12 or 16 weeks after surgery, and findings were analysed by routine microscopy and immunohistochemistry for proliferation (Ki67) and apoptotic (Caspase-3) markers. Grafts were fully incorporated in all specimens. Pronounced resorption was observed in experiment 1. Minimal loss of graft volume was seen in experiment 2 specimens without membrane displacement. A remarkable increase in the augmented region of the mandible was obse...
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with ...
DescriptionThis new research programme activity on Urban Atmospheric Science will deliver aspects of the NERC strategy: Next Generation Science for Planet Earth. It has been developed as part of the Environment, Pollution & Human Health theme. Research in the Environment, Pollution & Human Health theme is directed at elucidating key environmental processes that form part of a causal pathway between an environmental hazard and disease outcome, and providing a predictive capability of the risk to human heal [continued...
Complications of non-union and avascular necrosis during fracture healing process are the most important problems. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necorsis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of national Medical Center during the period form August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography one. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal ...
Bony craniofacial deficits resulting from injury, disease, or birth defects remain a considerable clinical challenge. In this study, microsphere-based scaffold fabrication methods were use to...Full Text Available
Following infection with the protozoan parasite Leishmania major, C57BL/6 mice develop a small lesion that heals spontaneously. Resistance to infection is associated with the development...Full Text Available
Recently, various types of allogeneic skin substitutes including cultured epidermal substitute (CES), cultured dermal substitute (CDS), and cultured skin substitute (CSS), which are composed of keratinocytes and/or fibroblasts as the cellular component(s), have been used as biological wound dressings. In our study, the allogeneic CDS was prepared by plating fibroblasts on a spongy collagen. The clinical evaluation was conducted using fresh or cryopreserved allogeneic CDS. In 145 of our clinical cases, 95% (138/145) of various wounds were evaluated as achieving good or excellent results, including 96% (22/23) of deep dermal burns (DDB) and dermal burns (DB), 100% (53/53) of partial-thickness donor wounds, 91% (21/23) of traumatic skin defects, 100% (5/5) of pressure ulcers, 82% (9/11) of chronic skin ulcers, 100% (6/6) of coverage for debrided DB, and 92% (22/24) of coverage for autologous meshed graft. The results obtained ...
Aminocyclopropane 1-carboxylic acid (ACC) synthase, a pyridoxal phosphate utilizing enzyme, catalyzes the conversion of S-adenosylmethionine to ACC, the rate limiting step in the biosynthesis of the plant hormone, ethylene. Ethylene, besides being involved in normal plant growth processes, is also produced in response to stress, e.g. wounding, pathogen infection, etc. The authors report the partial purification (400 fold) of ACC synthase from wounded pink tomato pericarp by classical techniques including ammonium sulfate precipitation, ion exchange and phenyl sepharose chromatography. Further purification results in a decrease in specific activity apparently due to the instability of the enzyme and the low levels present in plant tissue. Radiolabeling of a pyridoxal phosphate-utilizing protein in the ACC synthase enriched fraction was achieved. Evidence that this radiolabeled protein is ACC synthase will be presented. Amino acid sequence ...
Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with ...
Polyurethane (PU) foam was combined with protein drug-loaded pH-sensitive alginate-bentonite hydrogel for wound dressings. Alginate is a linear copolymer composed of 1?4-linked ?-D-mannuronic acid (M) and its c-5-epimer ?-Lguluronic acid (G). The amount of (M) and (G) and their sequential distribution are varied depending on the alginate source. Soluble sodium alginate can become a hydrogel when cross-linked with divalent cations and has widespread applications in the food, drink, pharmaceutical and bioengineering industries. Recently, it has been also proposed as a biomaterial for drug delivery systems. Bentonites are the natural inorganic polymers consisting of a large proportion of expandable clay minerals with a three-layer structure such as montmorillonite, beidellite, nontronite, etc...
Nitric oxide (NO) and related molecules such as peroxynitrite, S-nitrosoglutathione (GSNO), and nitrotyrosine, among others, are involved in physiological processes as well in the mechanisms of response to stress conditions. In sunflower seedlings exposed to five different adverse environmental conditions (low temperature, mechanical wounding, high light intensity, continuous light, and continuous darkness), key components of the metabolism of reactive nitrogen species (RNS) and reactive oxygen species (ROS), including the enzyme activities L-arginine-dependent nitric oxide synthase (NOS), S-nitrosogluthathione reductase (GSNOR), nitrate reductase (NR), catalase, and superoxide dismutase, the content of lipid hydroperoxide, hydrogen peroxide, S-nitrosothiols (SNOs), the cellular level of N...
Background This study aimed to evaluate laparoendoscopic single-site (LESS) adrenalectomy via the retroperitoneal approach using the Alexis wound retractor with standard laparoscopic instrumentation. Methods Since October 2009, seven LESS retroperitoneal adrenalectomies have been completed successfully with a homemade single port created using an Alexis wound retractor as an access platform through a 3-cm incision beneath the tip of the 12th rib. Results All the LESS procedures for these seven patients with adrenal tumors (size, 1.3?6.0?cm; 4 right, 1 left) were completed successfully without traditional laparoscopic conversion or complication. The average operative time was 159?min, and the estimated blood loss was 100?ml. The average hospital stay was 2?days (range, 1?3?days). Conclusion...
New nanofibers containing poly(vinyl pyrrolidone)-iodine complex (PVP-iodine) were obtained by electrospinning in order to prepare materials suitable for wound dressings. Different approaches were used: a one-step method based on electrospinning of PVP-iodine or poly(ethylene oxide)/PVP-iodine solutions and a three-step method based on electrospinning of PVP or poly(ethylene oxide)/PVP mixed solutions followed by photo-mediated crosslinking of the obtained nanofibers and subsequent complexation with iodine. The average diameters of the fibers were in the range 150-470nm depending on the composition and on the applied field strength (AFS) and increased with increasing the amount of PEO in the spinning solutions. Higher AFS resulted in greater fiber diameter and in size distribution broadeni...
Gelatine is a reliable tissue simulant in wound ballistic experiments. The projectile penetrating the gelatine transfers energy and causes radial cracks according to the temporary cavity. Thus the crack length is a function of the energy spent in the medium. In practice the fissures are poorly contrasted for which reason an enhancement of contrast was searched. A series of six shoots with expanding bullets (9mmx19 Action-5, 9mmx19 Quick Defense 1, 5.56mmx45 Styx Action) was realized on 10% gelatine blocks at 4^oC temperature. Three blocks were marked with acryl paint on the front, three blocks were shot native. The blocks were cut in slices of 1cm thickness and optically scanned. The evaluation was performed according to Fackler's wound profile, the total crack length method and the polygo...
Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hosp...
Abstract Aims: To develop an in vitro flat-bed perfusion biofilm model that could be used to determine the antimicrobial efficacy of topically applied treatments. Methods and Results: Pseudomonas aeruginosa and Staphylococcus aureus biofilms were grown within continuously perfused cellulose matrices. Enumeration of the biofilm density and eluate was performed at various sampling times, enabling determination of the biofilm growth rate. Two antimicrobial wound dressings were applied to the surface of mature biofilms and periodically sampled. To enable real-time imaging of biofilm growth and potential antimicrobial kinetics, a bioluminescent Ps. aeruginosa biofilm was monitored using low-light photometry. Target species produced reproducible steady-state biofilms at a density of c. 107 per b...
Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.
Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available
A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.
Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.
The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.
Transforming growth factor (TGF)-beta isoforms (TGF-beta 1, -beta 2, and -beta 3) regulate cell growth and differentiation and have critical regulatory roles in the process of tissue repair and remodeling....Full Text Available
The completed ribbon-winding theory, including temperature loading of the high-pressure compound vessel, was proposed. The influence of the bending stress in the wound ribbon is taken into account. Internal core of the compound vessel consists of matrix and ring, made of different materials. The relations were derived in analytical form, describing the radial distribution of necessary tangential prestressing.
The main aim of sanitary pass-control regime is to prevent propagation of radioactive contamination outside the area of emergency-rescue works and guarantee of sanitary treatment of all persons having radioactive contamination. The paper has studied the questions of organization of sanitary pass-control regime, arrangement of sanitary treatment of the injured persons and rendering first aid in case of radioactive contamination of wounds. 5 refs.
In the 21st century, eighty years after William Baer presented his groundbreaking work treating bone and soft tissue infections with live maggots, thousands of therapists around the globe have rediscovered...Full Text Available
A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.
Dialdehyde cellulose (DAC) was prepared by periodate oxidation of various cellulosic materials in the form of sutures and bandages. The suitability of using DAC for making bioabsorbable sutures and antimicrobial wound dressing bandages was studied. The investigations indicated that DAC combines the requisite mechanical strength with an inherent antimicrobial nature. It was found that the oxidation of cellulose to yield DAC also rendered it bioabsorbable. The DAC was coated with different concentrations of urea formaldehyde in order to improve the mechanical properties for making sutures. PMID:3719037
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
Penile rehabilitation has been an area of intense study and debate over the last decade. Interest in this topic was stimulated by the observation that erectile dysfunction remained a significant problem after radical prostatectomy despite meticulous nerve-sparing technique. Smooth muscle alterations and fibrotic changes in the penis were identified as the underlying causes of penile atrophy, veno-occlusive dysfunction, and Peyronie's-like changes that were observed after surgery. Initial observations that intracavernous injection therapies used on a regular basis postoperatively resulted in improvements in the return of spontaneous erectile function led to the development of penile rehabilitation protocols. Chronic dosing of oral type V phosphodiesterase inhibitors is now commonly used by urologists after radical prostatectomy despite a lack of convincing evidence from randomized, placebo-controlled clinical trials. Use of local therapies to heal the penis may have ...
Abstract Objectives: The purpose of this study was to evaluate the osseointegration of the dental implants placed into the mandible augmented with different techniques in pigs. Material and methods: Four adult domestic pigs were used. Horizontal augmentation of the mandible was performed in animals by using vascularized femur flap (VFF), non-vascularized femur graft (NVFG) and monocortical mandibular block graft (MG). After 5 months of healing 10 dental implants were placed into each augmented site. The pigs were sacrificed after 3 months of healing. Undecalcified sections were prepared for histomorphometric analysis. Results: Mean bone-implant contact (BIC) values for implants placed into MG, NVFG and VFF were 57.38 11.97%, 76.5 7.88%, 76.53 8.15%, respectively. The BIC values of NVFG and...
We review the status of free electron laser (FEL) research being conducted at LBL and LLNL as part of a broader program of research on two beam accelerators (TBAs). Induction accelerator-driven FELs for use as power sources for high-gradient accelerators are discussed, along with preliminary cost estimates for this type of power source. Finally, a promising new version of an FEL/TBA is described. 25 refs., 1 fig., 3 tabs.
We have performed molecular dynamics simulations of radiation damage in fused silica. In this study, we discuss the role of successive cascade overlap on the saturation and self-healing of oxygen vacancy defects in the amorphous fused silica network. Furthermore, we present findings on the topological changes in fused silica due to repeated energetic recoil atoms. These topological network modifications consistent with experimental Raman spectroscopic observation on neutron and ion irradiated fused silica are indicators of permanent densification that has also been observed experimentally.
We report a case of stress fracture of the clavicle associated with sternocostoclavicular hyperostosis. A 60-year-old man sustained a stress fracture of the right clavicle with no history of trauma. On radiography, hyperostosis of the anterior chest wall and ankylosis of the sternoclavicular joint were evident in addition to the fracture. Fracture healing was uneventful after 2.5 months. Ankylosis of the sternoclavicular joint may have caused increased stress at the midshaft of the clavicle by daily activity or minor trauma. Such a fracture is a rare complication of sternocostoclavicular hyperostosis. (orig.)
Linearly polarized laser radiation accelerates electrons to very high velocities and these electron form a sheath layer on the rear side of thin targets where preferentially protons are accelerated. When mass-limited targets are used, the lateral transport of the absorbed laser energy is reduced and the accelerating field is enhanced. For targets consisting of two ion species, heavier ions facilitate formation of quasi-monoenergetic bunch of lighter ions. For circularly polarized light, fast electron production is suppressed by the absence of the oscillatory component of the ponderomotive force. Ions are accelerated on the front side by the separation field and very thin foil can be accelerated as one massive quasi-neutral block. As all ion species acquire the same velocity, this acceleration mechanism is preferred for heavier ions.
Discussions were given on mullite/SiC composite ceramics as to crack size dependence of their crack healing behavior, and high-temperature strength properties. Test specimens used in the experiment are sinters of mullite powder added with SiC powder at 20% by volume, and hot-pressed under conditions of a sintering temperature of 1650 degC, time of four hours, and a pressure of 35 MPa. In the experiment, a pre-crack was introduced at the center of a test specimen by using a Vickers hardness meter, and a heat treatment was performed in atmosphere at 1300 degC for one hour. A four-point bending test was conducted in atmosphere as a strength test. Conditions in test specimens were investigated by using SEM observation, a laser microscope and X-ray diffraction. The following findings were obtained as a result of the experiment: the bending strength for the pre-cracked material is about 140 MPa against that of a smooth material of 342 MPa, but it increased to 517 MPa ...
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)
The collaboration between the Los Alamos National Laboratory and the National Bureau of Standards (NBS), started in 1979, has led to the development of an advanced c-w microtron accelerator design. The four 2380-MHz NBS accelerating structures, containing a total of 184 accelerating cavities, have been fabricated and delivered. New fabrication methods, coupled with refinements of hydrogen-furnace brazing techniques described in this paper, allow efficient production of side-coupled structures. Success with the NBS RTM led to Los Alamos efforts on similar 2450-MHz accelerators for the microtron accelerator operated by the Nuclear Physics Department of the University of Illinois. Two accelerators (each with 17 cavities) have been fabricated; in 1986, a 45-cavity accelerator is being fabricated by private industry with some assistance from Los ...
The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, electron beams, plasma, ...
Abuzakuk T, Coward P, Shenava Y, Kumar VS, Skinner JA. The management of wounds following primary lower limb arthroplasty: a prospective, randomised study comparing hydrofibre and central pad dressings. Pris en charge des plaies apres arthroplastie primaire du member inferieur: une etude randomisee prospective comparant hydrofibre et pansements central pad La prise en charge des plaies apres arthroplastie du member inferieur n'a pas fait l'objet de recherches approfondies, essentiellement car ces plaies cicatrisent habituellement sans complications. Cependant, lorsque des implants prothetiques sont utilizes, les serieux problemes de plaies peuvent devenir desastreux. Nous rapportons les resultants d'une etude prospective, randomisee, controlee comparant un hydrofibre et un pasnement centra...
The author resumes what is actually known about the behaviour of war projectiles in the target (wound ballistics). This is function of their nature, their velocity, their air trajectory. The difference between lesions due to slow moving bullets and these due to projectiles with a high kinetic energy is outlined. The last ones create, through the temporary cavitation effect, lesions at distance from the residual visible tract, particularly in the vascular conduits. The therapeutic conclusions, which derive from those ballistic behaviours, are briefly described in matter of repair of vascular war injuries [Acta chir. belg., 1982, 82, 457-461]. PMID:7148288
The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)
We propose unsteady-state reverse osmosis cell modelling in two dimensions. The convection-diffusion equation describing the concentration of the relevant chemical species is solved by a finite difference technique, while the velocity field is described by empirical expressions for spiral-wound membrane cells. A non-constant permeability is introduced to take into account the effects of membrane compaction at high operating pressures. The role of concentration polarization is discussed for different values of the parameters describing the global process. Finally, the model is applied to predict the effects of a pulsating flow where a cyclic pressure feed is adopted to enhance the permeate flux. In this context, an experimental validation of the model is proposed.
We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.
ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...
"American dominance in the study and development of high-energy particle physics may be seriously compromised, according to a report issued by the National Academy of Sciences, unless efforts are made to ensure that the next high-energy particle accelerator - the International Linear Collider (ILC) - will be constructed in the U.S.
Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy...Full Text Available
We describe the lethal, recessive accelerated-cell-death11 Arabidopsis mutant (acd11). Cell death in acd11 exhibits characteristics of animal apoptosis...Full Text Available
A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion power plants are now projected to be cost-competitive with other conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost ...
A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion power plants conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are presented and discussed, ...
This paper describes the needs, reasoning, approaches, and technical details to establish a practical accelerated weathering test (AWT) protocol for indoor testing of the photothermal stability of encapsulation materials and encapsulated solar cells and minimodules.
A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.
The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available
The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.
There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
OBJECTIVE: To increase cost-efficiency while maintaining the standard of medical care, an accelerated surgical stay program for patients having breast surgery was instituted. SUMMARY BACKGROUND DATA:...Full Text Available
Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) are promoting the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint project prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. It was originally written in English and translated into Japanese with some corrections. (author)
Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.
The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.
The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).
Tthe acceleration of a liquid from a cylindrical container by the products of instantaneous detonation of a superimposed explosive charge (implosion method) is studies numerically in a two-dimensional formulation. Analytical formulas for the asymptotic velocities of liquid expansion and acceleration of the container body were obtained using numerical calculations in a one-dimensional approximation. The effect of the fracture of the body on the velocity of liquid expansion was studied in a two-dimensional formulation.
The SciDAC2 accelerator project at SLAC aims to simulate an entire three-cryomodule radio frequency (RF) unit of the International Linear Collider (ILC) main Linac. Petascale computing resources supported by advances in Applied Mathematics (AM) and Computer Science (CS) and INCITE Program are essential to enable such very large-scale electromagnetic accelerator simulations required by the ILC Global Design Effort. This poster presents the recent advances and achievements in the areas of CS/AM through collaborations.
A prototype of a muffin-tin accelerating structure operating at 32 times the SLAC frequency (2.856 GHz) was built for research in high gradient acceleration. A traveling-wave design with single input and output feeds was chosen for the prototype which was fabricated by wire electrodischarge machining. Features of the mechanical design for the prototype are described. Design improvements are presented including considerations of cooling and vacuum.
The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.
Urticaria is one of the most common dermatoses during the childhood, but it is very rare in the neonates. A 17-day-old infant with a generalized urticaria was admitted to our pediatric emergency unit. The mother of the infant reported having applied water boiled with stinging nettle (Urtica dioica) onto her nipples twice a day (before and after each breastfeeding) for 2?days in order to heal her nipple cracks. Serum total immunoglobulin E (IgE) and specific IgE levels for stinging nettle were high in the infant and the mother. The rashes began to regress within the first day of the hospitalization and disappeared completely on the second day without treatment. The skin prick test with the water boiled with stinging nettle was positive for the infant with significant induration, but not for...
An asymptomatic pink discoloration of a maxillary right fourth premolar tooth was discovered during a routine oral examination on a 9 year-old Belgian Malinois dog. A radiolucent lesion was seen in the pulpal chamber on radiographic examination. The lesion had perforated the mesiobuccal root of the tooth. The primary differential diagnosis was idiopathic internal resorption. The tooth was treated by partial resection (removal of the mesiobuccal root and associated crown). A vital pulpotomy and amalgam restoration was performed on the remaining tooth structure. A follow-up 1 year later demonstrated a successful treatment outcome. The animal was asymptomatic and able to perform military duties. Clinical and radiographic signs of healing were evident and the tooth was functional. PMID:10518874
Two cases of tetracycline ulcers of the oesophagus are reported and compared with thirteen other cases from the literature. In most cases, the patients had taken their capsules with little or no fluid just before going to bed. Some hours later they developed retrosternal pain that was intensified by swallowing. Endoscopy showed sharply demarcated greyish-white areas of mucosal damage which represented layers of stratified squamous cells, separated by oedema, and a dense neutrophilic infiltration of the lamina propria and the muscularis mucosa. Roentgenology was unsuitable to detect the lesions. They healed without complications within one to six weeks. Prolonged retention of the capsules in the oesophagus is thought to cause the mucosal damage. Patients on oral tetracycline or doxycycline treatment should therefore be instructed to take their capsules with a meal or with copious water and not just before going to bed.
Scuffing damage is catastrophic and typically not self-healing. It severely affects the life and reliability of engineering components, such as cams, roller bearings, piston rings, cylinder bores and gears. Gray iron and 1080 steel are important materials for these extremely demanding structural components. There have been several scuffing studies done in the past with various types of steel and cast iron. However, in these studies there was no attempt to compare the scuffing resistance of cast iron and steel materials with similar matrices. In the present study, scuffing tests were performed with the matrices of gray iron and 1080 steel being fully pearlitic. This allows for a direct evaluation of the effect of the graphite flakes on scuffing resistance. The scuffing behavior for these ma...
The present paper describes the phytochemical investigation and biological activities of the chloroform, ethyl acetate and methanol extracts of leaf decocts of M. truncata Reiss (Celastraceae). Our studies afforded two flavonoid glycosides, quercetin-3-O-rhamnopyranosyl-O-glucopyranosyl- O-rhamnopyranosyl-O-galactopyranoside (1) and kampferol-3-O-rhamnopyranosyl-O-glucopyranosyl- O-rhamnopyranosyl-O-galactopyranoside (2) from the methanolic extract and dulcitol (3) from the ethyl acetate extract. Ethyl acetate and methanol extracts exhibited considerable antiulcerogenic and analgesic activities. The results of the phytochemical studies suggest that the healing activity of methanol extracts can be related to the presence of glycosyl flavonoids. (author)
IntroductionMost clinical studies on the outcome of apical surgery concentrate on periapical healing based on radiographic and clinical characteristics (signs and symptoms). This study focuses on long-term changes in periodontal parameters after apical surgery. MethodsPeriodontal parameters (ie, probing depth [PD], level of gingival margin [GM], and calculated clinical attachment level [CAL]) were collected at baseline and at 1 and 5 years after apical surgery. Changes in PD, GM, and CAL were calculated over time and were also evaluated in relation to patient-, tooth-, and treatment-related covariables. ResultsOne hundred eighty-six of 242 initially identified teeth could be evaluated. Significant changes in GM and CAL were observed at facial sites during the first year after surgery (mean...
Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)
AbstractBackground: So far, infliximab (IFX) therapy for the treatment of Crohn's disease (CD) has generally been guided by clinical symptoms. Data on treatment response as ascertained by endoscopy in IFX therapy are scarce. The aims of this study were to measure the endoscopic response rate during IFX induction and maintenance therapy in luminal CD, and also evaluate the role of endoscopy in monitoring IFX therapy. Methods: Data obtained from 71 patients with active luminal CD and treated with IFX were analyzed retrospectively. The endoscopy findings were scored according to mucosal activity as: 0 (remission), 1-2 (mild), 3-4 (moderate), and 5-6 (severe). A positive endoscopic response was determined by a decrease in score of at least two points and mucosal healing was assigned a score of...
Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This technique appears to be a ...
The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.
We consider a unified model of Fe ion acceleration in the solar corona. The model comprises charge-changing processes, Coulomb energy losses, and both regular and stochastic acceleration. At a given acceleration scenario, the type of acceleration is found to have a minor effect on the mean charge states, but the shapes of the charge-state distributions produced by regular acceleration and by stochastic acceleration are different. During a continual acceleration at coronal temperatures, iron ions typically follow rising trajectories on the charge-energy plane. These trajectories are situated below the mean equilibrium charge curve defined from the balance of ionization and recombination at fixed energy. During stopping, the iron ions cross the equilibrium charge curve and run through a series of charge states above the mean equilibrium charge ...
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new ...
With the aim of demonstrating the usefulness of computerised tomography (CT) findings in the planning of brain neurosurgery in gunshot victims, for prompt and successful treatment, 30 patients with brain gunshot wounds were examined with CT over 5 years. The mortality rate of firearm wounds of the skull base was 34% higher than that of the hemisphere; this is due to carotid hemorrhage and midbrain damage. Such traumas require emergency radiological diagnosis and neurosurgical treatment because of their severity and early irreversible complications. Complex operations and skilled surgeons may prevent disabling postoperative sequels. CT findings are indispensable and must be correctly interpreted. The radiologist and the neurosurgeon must collaborate closely and both must consider several diagnostic factors affecting surgical planning. [Italian] Scopo dello studio e' stato quello di dimostrare l'utilita' della ...
The main facets of professor N.I. Pirogov's professional activity are outlined. Forensic medicine (in the first place its organizational and practical aspects) was an integral component of his scientific and clinical work, along with applied anatomy and surgery. Landmark publications of N.I. Pirogov are listed with special reference to those concerned with forensic medical expertise of medical malpractice cases, postmortem inspection and intravital examination procedures, wound ballistics studies, the atlas of forensic pathology, etc. The surgeon and anatomist N.I. Pirogov can be justly regarded as a founder of forensic medicine in this country. PMID:21866839
Russian field surgery with its long history and distinctive characteristics has accumulated great experience in the long-time practice of warfare. Chinese field surgery was established and developed on the basis of studying from the Russian model, which opened up new areas of traffic medicine, molecular traumatology and assessment of biological effects on weapon destruction and carried out in-depth research on wound ballistics, blast injury, burns and combined injury etc. through decades of construction with continuous development and innovation, and a series of major achievements have been made in these fields. By making comparative study on the historical evolution, structure system, characteristics of campaigns and development of society between Chinese and Russian field surgery, it can be found that there are great gaps between them and we should strengthen the research for more rapid development. PMID:20510098
It is important for the trauma surgeon to understand the basic principles of terminal gunshot ballistics and the study of the projectile's effect on striking soft tissue. The amount of kinetic energy dissipated to the tissue is directly related to the mass and velocity of the projectile as follows: K = MV2/2. Doubling the velocity quadruples the energy, while doubling the mass only doubles the energy. A temporary tissue cavity is produced as the striking projectile compresses the surrounding tissue; the higher the energy release, the more extensive the inapparent compressive damage. The permanent cavity that remains is the result of extrusion of tissue from the pathway of the projectile. The higher the velocity, the higher the likelihood of extensive damage. If the missile expands or fragments within the tissues, more damage will occur. PMID:6847483
The objective of this Task Group is the coordination of research studies on biokinetic models and the evaluation of the implications of new biokinetic models on dose assessment and safety standards. For this the new ICRP models, which will be used for a revision of ICRP Publications 30, 54, 68 and 78, are implemented into six different computer codes in five European countries and quality assured by intercomparison procedures. The work has started with the implementation of the new ICRP Alimentary Tract Model. New systemic models and the new NCRP wound model will follow. The work also includes the evaluation of experimental results in terms of formulation by the new model structures and a quality assurance of model formulation. PMID:17556343
Many alternative therapies are used as first aid treatment for burns, despite limited evidence supporting their use. In this study, Aloe vera, saliva and a tea tree oil impregnated dressing (Burnaid) were applied as first aid to a porcine deep dermal contact burn, compared to a control of nothing. After burn creation, the treatments were applied for 20 min and the wounds observed at weekly dressing changes for 6 weeks. Results showed that the alternative treatments did significantly decrease subdermal temperature within the skin during the treatment period. However, they did not decrease the microflora or improve re-epithelialisation, scar strength, scar depth or cosmetic appearance of the scar and cannot be recommended for the first aid treatment of partial thickness burns. PMID:18603378
In a retrospective single-centre study 170 consecutive patients were included who received a Kotz modular prosthesis after resection of bone tumours of the proximal femur to evaluate the management of prosthetic infection. Infection occurred in 12 of 166 patients available for follow-up (six males; six females; mean age, 47?years; range, ten to 75?years) after a mean of 39?months (range, one to 166?months; infection rate, 7.2%). Mean follow-up was 54?months (range, four to 200?months). One patient died of septic shock. Two patients were treated by wound revision only. Treatment of infection in the remaining patients was one-stage revision in eight and hip disarticulation in one. Infection control by one-stage revision was achieved in five of eight patients; re-infection occurred in three p...
AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...
Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from ...
Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from ...
Particle physics is driven by five great topics. Neutrino oscillations and masses are now at the fore. The standard model with extensions to supersymmetry and a Higgs to generate mass explains much of the field. The origins of CP violation are not understood. The possibility of extra dimensions has raised tantalizing new questions. A fifth topic lurking in the background is the possibility of something totally different. Many of the questions raised by these topics require powerful new accelerators. It is not an overstatement to say that for some of the issues, the accelerator is almost the experiment. Indeed some of the questions require machines beyond our present capability. As this volume attests, there are parts of the particle physics program that have been significantly advanced without the use of accelerators such as the subject of neutrino oscillations and many aspects of the particle-cosmology interface. At this ...
A study was conducted under the auspices of the Coordinating Research Council, Inc. (CRC) to assess the potential effects of gasoline octane quality on vehicle acceleration performance. Twelve participating laboratories, representing both the oil and the automotive industries, tested a total of 182 vehicles as part of the 1989 CRC Octane Number Requirement Survey. The vehicles consisted of 78 with electronic knock control systems and 104 without. All testing was performed using the 1989/1990 CRC FBRU fuel series. The results showed that acceleration performance of vehicles with knock sensors was significantly affected by gasoline octane quality. Octane effects on acceleration performance were most pronounced at maximum-throttle (detent) conditions and at octane levels below the vehicles' octane requirements; however, some knock-sensor vehicles did show improved acceleration performance with ...
The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.
This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.
This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.
Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.
A one parameter family of iterative methods for the simultaneous approximation of simple complex zeros of a polynomial, based on a cubically convergent Hansen-Patricks family, is studied. We show that the convergence of the basic family of the fourth order can be increased to five and six using Newtons and Halleys corrections, respectively. Since these corrections use the already calculated values, the computational efficiency of the accelerated methods is significantly increased. Further acceleration is achieved by applying the Gauss-Seidel approach (single-step mode). One of the most important problems in solving nonlinear equations, the construction of initial conditions which provide both the guaranteed and fast convergence, is considered for the proposed accelerated family. These cond...
and propels the projectile to a velocity sufficient to reach ..... CLF3 + N2 4 .... 5 inches or greater accelerates a finned projectile to the veloc ...
The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode, accelerating a proton beam into stationary targets/detectors, as well as a Colliding Beam mode, continuously colliding counter rotating beams of protons and antiprotons. Upon completion, the Tevatron cryogenic system became the world's largest helium refrigeration system. In 1993, the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history, experiences and statistics of the Tevatron, with an emphasis on the cryogenic system, is ...
We study a two-level atom in interaction with a real massless scalar quantum field in a spacetime with a reflecting boundary. The presence of the boundary modifies the quantum fluctuations of the scalar field, which in turn modifies the radiative properties of atoms. We calculate the rate of change of the mean atomic energy of the atom for both inertial motion and uniform acceleration. It is found that the modifications induced by the presence of a boundary make the spontaneous radiation rate of an excited inertial atom oscillate near the boundary and this oscillatory behavior may offer a possible opportunity for experimental tests for geometrical (boundary) effects in flat spacetime. While for accelerated atoms, the transitions from ground states to excited states are found to be possible even in a vacuum due to changes in the vacuum fluctuations induced by both the presence of the boundary and the acceleration of atoms, ...
An almost linear optimization problem of importance in vibration isolation has been identified and algorithms were developed to minimize the forced vibrational response of structural systems. The constraints can be either displacements of accelerations. T...
A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.
Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, ...
Modern day accelerator development encompasses a myriad technologies required for their diverse needs. Whereas RF, high voltage, vacuum, cryogenics etc., technologies meet their functional requirements, high finish lapping processes, ceramic-metal joining, oven brazing, spark erosion or wire cutting etc., are a must to meet their fabrication requirements. Electromagnetic (EM) forming technique falls in the latter category and is developed as a special technology. It is currently catering to the development as a nuclear reactor technology, but has the potential to meet accelerator requirements too. This paper highlights the general principle of its working, simple design guidelines, advantages, and suggests some specific areas where this could benefit accelerator technologies
A compact proton accelerator for medical applications is being developed at Lawrence Livermore National Laboratory. The accelerator architecture is based on the dielectric wall accelerator (DWA) concept. One critical area to consider is the switch region. Electric field simulations and thermal calculations of the switch area were performed to help determine the operating limits of rmed SiC switches. Different geometries were considered for the field simulation including the shape of the thin Indium solder meniscus between the electrodes and SiC. Electric field simulations were also utilized to demonstrate how the field stress could be reduced. Both transient and steady steady-state thermal simulations were analyzed to find the average power capability of the switches.
Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)
Government policies that encourage exploitation--in particular excessive logging and clearing for ranches and farms--are largely to blame for the accelerating destruction of tropical forests. This paper surveys the problem in detail and briefly recommends potential solutions.
FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results ...
The next generation of particle accelerator is currently being designed at CERN. An understanding of the market forces in the computer industry will play a crucial role in the success of the project.
added to provide resistance to UV degradation, and vulcanization control. ...Sulphur is used to vulcanize the rubber ...additives and solvents age resistors, processing aids, accelerators, vulcanizing agents, softeners and fillers
This volume is based on the proceedings of the CERN Accelerator School's course on Applied Geodesy for Particle Accelerators held in April 1986. The purpose was to record and disseminate the knowledge gained in recent years on the geodesy of accelerators and other large systems. The latest methods for positioning equipment to sub-millimetric accuracy in deep underground tunnels several tens of kilometers long are described, as well as such sophisticated techniques as the Navstar Global Positioning System and the Terrameter. Automation of better known instruments such as the gyroscope and Distinvar is also treated along with the highly evolved treatment of components in a modern accelerator. Use of the methods described can be of great benefit in many areas of research and industrial geodesy such as surveying, nautical and aeronautical engineering, astronomical radio-interferometry, metrology of ...
magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...
An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)
In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power polymerization curved surface fitting. Master-slave reference frame is ...
New furnaces were built based on fused silica with NiChrome heating elements custom-wound on alumina ceramic to self-compensate for induced magnetic fields during operation. During tests these furnaces failed due to thermal stresses caused by the high temperature cement used to hold the alumina ceramic in place. As a third solution pieces of boron nitride have been procured from which new furnace bodies will be machined during the third quarter. In order to increase the in-house capacity for machining ceramic parts a small lathe was ordered. The implementation of the LabView data acquisition software from National Instruments, Inc. took more time than anticipated and is still not completed. Major difficulties had to be overcome during the integration of the separate positive and negative high voltage supplies ({plus_minus}1000V). It became apparent that a custom-designed switch had to be installed to safeguard the data acquisition modules and the Apple Macintosh ...
CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography technique. The reanimator was always presented to monitor the patients' ...
PurposeThis prospective study followed 61 patients who were partially dentulous and considered to have insufficient bone volume for routine implant treatment and consequently underwent sinus inlay bone grafting.Patients and MethodsThe patients were treated with maxillary sinus floor augmentation with particulated autogenous bone from the mandibular ramus/corpus. After a healing period, dental implants (n = 180) were installed.ResultsRadiographic examination revealed average residual vertical bone heights of 6.5 mm in the first premolar region, 3.8 mm in the second premolar region, 3.5 mm in the first molar region, and 2.6 mm in the second molar region. The average implant lengths were 12 mm in the first premolar region and 11 mm in the second premolar, first, and second molar regions. All ...
In the years 2004 and 2005, Korea became a prospective nation noteworthy in the world through the epochal development of genetic engineering in our country. Obstinate or incurable diseases were expected to be healed in a few years by a Korean geneticist. So many worldwide patients of obstinate or incurable diseases took notice of the research outcomes and organized an aid association to collect supporting funds. World renowned journals such as 'Nature' and 'Science' published Dr. Hwang's theses. A long and distant way remedy to obstinate diseases seemed to be closer at hand so early. However, a stem cell fraud case emerged throughout the world in late 2005, the pride of the Korean people was destroyed. With this as a momentum, voices of self reflection by scientific circles were raised. The purpose of this study is not in finding the truth of the stem cell research but to propose an effective management and control measures for the future in planning, implementing, ...
Severe damage to the pelvic viscera is a complication of irradiation therapy that, unfortunately, cannot always be avoided. Resulting rectal and rectocolonic strictures, rectovaginal fistulas, and shortening and stenosis of the vagina present very difficult problems that frequently require a colostomy for relief and may permanently impair sexual function. The authors present a new approach to correction of these unfortunate lesions based on the use of proximal nonirradiated colon which serves as a vascular pedicle graft to correct the defect without a complicated and massive resection. Twenty-two such operations have been done with 19 satisfactory to excellent results and two total failures (one death from small bowel complications). All patterns and combinations of irradiation injury have been found amenable to this technique of repair. These have included both web and linear strictures with and without fistulas. In half of the patients, it was possible to make use of normal colon ...
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).
135 patients with histologically proven Ewing's sarcoma, treated at the Institute Gustave Roussy between 1960-1974 were reviewed in order to establish the effectiveness and the complications associated with radiotherapy. In 133 patients, a dose of at least 60 Gy for long bones, 55 Gy for flat bones and 45 Gy for vertebrae was given. 26 major complications (of which more than one occured in certain patients) were observed: 12 cases of growth retardation, loss of joint function in 7 cases, 3 fractures, 2 osteonecroses, 2 cases of delayed healing, one massive soft tissue fibrosis, 1 abdominocutaneous fistula, 2 cases of symptomatic pulmonary fibrosis with associated infection, 2 cases of radiation enteropathy, 2 of mammary hypoplasia and 1 osteosarcoma developing in an irradiated zone. These complications necessitated 12 surgical interventions, including 4 disarticulations or amputations. The incidence of complications can be related to the age of the patient and to ...
Mesh network applications are used by utilities for metering, demand response, and mobile workforce management. This presentation provided an overview of a multi-dimensional mesh application designed to offer improved scalability and higher throughput in advanced metering infrastructure (AMI) systems. Mesh applications can be used in AMI for load balancing and forecasting, as well as for distribution and transmission planning. New revenue opportunities can be realized through the application's ability to improve notification and monitoring services, and customer service communications. Mesh network security features include data encryption, data fragmentation and the automatic re-routing of data. In order to use mesh network applications, networks must have sufficient bandwidth and provide flexibility at the endpoint layer to support multiple devices from multiple vendors, as well as support multiple protocols. It was concluded that smart meters will not enable energy response ...
This prospective study describes and evaluates a surgical approach for 3D reconstruction of the posterior maxilla with autogenous mandibular bone in 16 patients (mean age 51 years). Bone blocks were harvested from the mandible and used as lateral or vertical block grafts (onlay); they were also partially milled and used for sinus elevation (inlay). In 4 cases, anorganic bovine bone was added at the periphery of the blocks. 4 months after grafting, implants were placed in a second operation and loaded after 12 weeks. Lateral and vertical augmentations were measured immediately after grafting and at re-entry for implant placement. Mean lateral augmentation performed was 5.5mm, reduced to 4.3mm (p<0.01) after 4 months' healing. Mean vertical augmentation was 3.2mm, reduced to 2.1mm (p<0.01) a...
The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary site is suspicious for recurrence or secondary neoplasm. ...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate ...
This paper extends the development of a new formulation of the theory of tachyons to encompass the dynamics of tachyons. Energy and momentum are discussed along with the proper mass of a tachyon. The transformation of force in extended relativity (ER) is derived. Acceleration in ER is also discussed, as well as the relationship between force and acceleration. Two simple examples relating to the motion of a charged tachyon are discussed, followed by a brief explanation of why tachyons cannot emit Cerenkov radiation in a vacuum. 13 refs., 3 figs.
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).
Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.
The salient features of the near-infrared free-electron laser (FEL) that is under construction at the new Darmstadt superconducting 130-MeV electron accelerator are discussed. Special attention is given to the layout and the parameters of the accelerator, the layout of the planned FEL experiment, the characteristics of the electron gun, the subharmonic chopper-buncher system, and the hybrid undulator system of the Darmstadt FEL. A comparison of the planned Darmstadt FEL with conventional lasers, with respect to the pulse and wavelength region, is presented. 15 refs.
The motion of an accelerated charge in a vacuum is analyzed, via the superposition principle and Fourier analysis, into uniform-motion components, which include bradyonic as well as tachyonic contributions. It is shown that the former contribute only to the induction fields whereas the latter are the source of the radiation emitted by the charge, via the Sommerfeld-Cerenkov mechanism. This result calls for a reexamination of some recently formulated theories of superluminal particles.
The structure of the P-2, S-1 accelerator mode with one step, S-1, on double period, P-2 for systems, described by the Harper mapping as well as by standard mapping, is analyzed. Detailed analysis of stability criteria is given and comparison with the results of numerical analysis is performed. Three-period compression of the P-2, S-1 island is revealed in the standard mapping. Refs. 7, figs. 7.
Modern particle accelerators offer new opportunities to dramatically reshape the way we think about nuclear energy, and challenge some of the thorniest problems linked to its industrial use, e.g. nuclear waste. A powerful proton accelerator driving a sub-critical fission reactor could be used for producing energy more safely and burning up the extra spent fuel which so far has been stored in geological repositories.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
We report acceleration of electrons moving in free space near an active Nd:YAG slab. The power of a non-relativistic beam of electrons has increased by more than 30% when the medium was excited. It is demonstrated experimentally that the energy gained by the electrons is linearly proportional to the energy stored in the medium. Moreover, the energy gain traces closely the population inversion inferred by monitoring the spontaneous radiation.
This paper describes the conversion from an existing production control computer, an SEL 840, to a DEC VAX 11/780. The plan is to add a layer of hardware to accomplish a smooth and gradual transition from the 840 to the VAX while leaving the underlying equipment unchanged. The architecture of the control system software is discussed for a large linear accelerator from the standpoint of its requirements and the particular design philosophy chosen.
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.
This annual report describes research activities which have been performed with the JAERI tandem accelerator and the Van de Graaff accelerator from April 1, 2000 to March 31, 2001. Summary reports of 46 papers, and lists of publication, personnel and cooperative research with universities are contained. (author)
Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.
Accelerated aging tests such as high temperature burn-in, which are in current use on Bendix Kansas City Division's (BKC) purchased small and medium scale integrated circuits, were evaluated to determine if they are effective and necessary to ensure the required reliability. A theoretical analysis, a literature search, and a study of lot acceptance results were used to assess the value of integrated circuit burn-in.
Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.
An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.
An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.
This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeV electron capability, for total skin irradiation for mycosis fungoides. The 6 MeV electron energy...Full Text Available
Using an anti-receptor mAb that blocks the attachment of echovirus 7 and related viruses (echoviruses 13, 21, 29 and 33), we have isolated a complementary DNA clone that encodes the human decay-accelerating...Full Text Available
Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.
We argue that the occurrence of late-time acceleration can conveniently be described by first-order general relativity covariantly coupled to fermions. Dark energy arises as a gravitationally driven BCS condensate of fermions which forms in the early universe. At late times, the gap and chemical potential evolve to have an equation of state with effective negative pressure, thus naturally leading to acceleration.
The contribution of pulsar accelerated nuclei to the cosmic rays inside the Galaxy is calculated assuming that a significant part of the pulsar rotational energy is lost on acceleration of iron nuclei extracted from the surface of the neutron star. Different models of the galactic pulsar population are discussed. It is shown that the best description of the observed cosmic ray spectrum and the mass composition between a few 10{sup 15} eV and a few 10{sup 18} eV is obtained for the model B of Lorimer et al. (1993)
The accelerating flow of a lighter continuous phase through a heavier one is considered. Small nonuniformities grow into large ones due to the Rayleigh-Taylor instability. An experiment exemplifying the large bubble formation due to Rayleigh-Taylor instability was performed and simulated using the PHOENICS 84 computer code. The same numerical procedure was applied to the two-phase flow in a gun barrel. It shows that the acceleration provided by the movement of the projectile can cause initial nonuniformities to grow with time.
Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.
A bibliography is presented of unclassified published and in-house technical material written by members of the Accelerator Technology Division, Los Alamos National Laboratory, since its inception in January, 1978. The author and subject concordances in this report provide cross-reference to detailed citations kept in a computer database and a microfilm file of the documents. The citations include an abstract and other notes, and can be searched for key words and phrases.
Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.
An S-brane solution with two non-composite electric branes and a set of l scalar fields is considered. The intersection rule for branes corresponds to the Lie algebra A_2. The solution contains five factor spaces with the fifth one interpreted as ``our'' 3-dimensional space. It is shown that there exists a time interval where accelerating expansion of ``our'' 3-dimensional space is compatible with small enough value of effective gravitational ``constant'' variation.
There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
The applicability of Broyden's second method for accelerating the convergence of self-consistent electronic-structure calculations based on the linearized augmented-plane-wave method is discussed in terms of a W(001) surface calculation. It is found that its use results in a significant improvement in the convergence of the calculation, and based on this it is concluded that its use should increase the size of the systems for which such calculations are feasible.
The author discusses the accelerated aging tests performed using Hondo and Maya as aging resids with a commercial large pore hydrotreating catalyst. The results from these tests were compared with those obtained under a normal full life test. The test resid was a sample of a typical refinery charge and the activities for sulfur and vanadium removal were determined at 720"0F after successive brief periods of exposure to the heavier oils.
Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.
It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the ...
Multi-beamlet focusing of an intense negative ion beam has been performed using the beamlet steering by the aperture displacement. The apertures of the grounded grid were displaced as all beamlets of 270 (18 x 15) in the area of 25 cm x 26 cm would be steered to a common point (a focal point) in both the two-stage and the single-stage accelerators. The multi-beamlets were successfully focused and the e-folding half width of 10 cm was achieved 11.2 m downstream from the ion source in both the accelerators. The corresponding gross divergence angle is 9 mrad. The negative ion beamlets are deflected by the magnetic field for the electron deflection at the extraction grid and the deflection direction oppositely changes line by line, resulting in the beam split in the deflection direction. This beamlet deflection was well compensated also using the beamlet steering by the aperture displacement of the grounded grid. The beam ...
Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from ...
The purpose of this paper is to present a summary of new methods, employing Lie algebraic tools, for characterizing beam dynamics in charged-particle optical systems. These methods are applicable to accelerator design, charged-particle beam transport, electron microscopes, and also light optics. The new methods represent the action of each separate element of a compound optical system, including all departures from paraxial optics, by a certain operator. The operators for the various elements can then be concatenated, following well-defined rules, to obtain a resultant operator that characterizes the entire system. This paper deals mostly with accelerator design and charged-particle beam transport. The application of Lie algebraic methods to light optics and electron microscopes is described elsewhere (1, see also 44). To keep its scope within reasonable bounds, they restrict their treatment of accelerator design and ...
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with ...
The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the ...
An Otto cycle engine with internal and external irreversibilities of friction and heat leakage, in which the heat transfer between the working fluid and the environment obeys linear phenomenological heat transfer law [q ?? ?(T ?1)], is studied in this paper. The optimal piston motion trajectory for maximizing the work output per cycle is derived for the fixed total cycle time and fuel consumed per cycle. Optimal control theory is applied to determine the optimal piston trajectories for the cases of with and without piston acceleration constraint on each stroke and the optimal distribution of the total cycle time among the strokes. The optimal piston motion with acceleration constraint for each stroke consists of three segments, including initial maximum acceleration and final maximum decel...
The Tevatron is a proton anti-proton accelerator collider operating at the Fermi National Accelerator Laboratory. The machine is currently delivering beam for the CDF and D0 experiments, which expect increasing luminosity until the conclusion of Run II, planned for 2009. The Laboratory defined a plan for achieving higher luminosity, and one of the tasks is the upgrade of the accelerator's beam position monitor (BPM). The Tevatron was built during the early eighties and some of its control systems, including the BPMs, are still the original ones. This paper describes the front-end software of the Tevatron BPM upgrade, from the requirements to the implementation, and the underlying hardware setup. The front-end software designed is presented, emphasizing its modularity and reusability, allowing it to be applied to other Fermilab machines.
The discovery that the cosmic expansion is accelerating has been followed by an intense theoretical and experimental response in physics and astronomy. The discovery implies that our most basic notions about how gravity work are violated on cosmological distance scales. One simple fix is the introduction of a cosmological constant into the field equations for general relativity. However, the extremely small value of the cosmological constant, relative to theoretical expectations, has led theorists to explore a wide variety of alternative explanations that involve the introduction of an exotic negative-pressure fluid or a modification of general relativity. Here we briefly review the evidence for cosmic acceleration. We then survey some of the theoretical attempts to account for it, including the cosmological constant, quintessence and its variants, mass-varying neutrinos, and modifications of general relativity, such as scalar-tensor and $f(R)$ ...
The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the ...
The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control system of any size ...
A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set.
This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory Editing and changes to the authors` contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on nine presentations: ``The Energy Exchange and Efficiency Consideration in Klystrons``, ``Some Properties of Microwave RF Sources for Future Colliders + Overview of Microwave Generation Activity at the University of Maryland``, ``Field Quality Improvements in Superconducting Magnets for RHIC``, ``Hadronic B-Physics``, ``Spiking Pulses from Free Electron Lasers: Observations and Computational Models``, ``Crystalline Beams in Circular Accelerators``, ``Accumulator Ring for AGS & Recent AGS Performance``, ``RHIC Project Machine Status``, and ``Gamma-Gamma Colliders.``
Phosphate/chromate and accelerated chromate coatings were produced on commercially available aluminium. The Cr, P and Fe components of the conversion coatings were determined by radioactive tracer technique. The tracer technique was combined with ion-exchange and film-sectioning methods to determine the chromium(III)/total chromium ratio in the accelerated chromate coating. It was found that during the acidic dissolution of the conversion coating the chromium(III)/total chromium ratio may suffer changes. The film-forming components in the metal/bath interface are supersaturated and deposited onto the aluminium. The identified components of the accelerated chromate coatings are Cr(OH)sub(3), Cr(OH)CrOsub(4) and Crsub(4)(Fe(CN)sub(6))sub(3) and the chromium(III)/total chromium ratio was found to be cca. 2/3. (author). 11 refs.; 5 figs.
Polarized electron sources for high energy accelerators took a significant step forward with the introduction of a new laser-driven photocathode source for the SLC in 1992. With an electron beam polarization of >80% and with {approximately}99% uptime during continuous operation, this source is a key factor in the success of the current SLC high-energy physics program. The SLC source performance is used to illustrate both the capabilities and the limitations of solid-state sources. The beam requirements for future colliders are similar to that of the SLC with the addition in most cases of multiple-bunch operation. A design for the next generation accelerator source that can improve the operational characteristics and at least minimize some of the inherent limitations of present sources is presented. Finally, the possibilities for producing highly polarized electron beams for high-duty-factor accelerators are discussed.
This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.
Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed ...
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented ...
Mineral carbonation is based on the reaction of carbon dioxide with metal-oxide bearing minerals, usually containing magnesium or calcium silicate, to form hardly soluble carbonates and other solid byproducts. The concept is based on acceleration of the naturally occurring rock weathering process. In the present work the calcium silicate is present in the mineral, wollastonite. To accelerate the process and make it potentially useful for practical applications, mineral carbonation is conducted here using an indirect two-step route in which the reactive component (Ca^2^+ ions in considered case) is first extracted from the mineral matrix and afterwards carbonated. Two solid byproducts are formed in this process: silica in the extraction step and calcium carbonate in the carbonation step. In...
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.
This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.
Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.
This presentation focuses on the steps taken by the Westinghouse Hanford Company to meet an accelerated schedule for configuration and implementation of the MULTI LIMS in a multiple laboratory environment. The Westinghouse Hanford Company purchased the MULTI LIMS Laboratory Information Management System in August, 1993. Hardware delivery began in October, 1993. Less than four months later, the initial configuration was released for use in two Westinghouse Hanford Company laboratories. Several major obstacles were overcome during implementation. These include information gathering for base table loading, user training, acceptance of the new system by users of a legacy system, and hardware configuration issues. In summary, steps needed to be taken to meet the accelerated implementation schedule of the MULTI LIMS at the Hanford Site. The obstacles faced were overcome through the in-depth knowledge and help of the vendor and the dedication and ...
Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton beam from the Tevatron collider.
Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
This paper shows how molecular theory paves the way for accelerated aging tests of safety-related equipment in nuclear power plants, as required by NRC qualification programs. Arrhenius' model, based on an equation, provides useful information regarding the extent of molecular change as a function of time and temperature. Critical to determining the aging characteristics and qualified life of organic materials is the activation energy concept, which is derived from information gathered when the molecular reaction of the material is documented over the entire life cycle. In accelerated-aging applications, the importance of the model lies in characterizing the chemical related reactions of materials. The problem with the Arrhenius approach is that, in generating a testing period of reasonable duration, a rather high test temperature must be selected which may lead to an added and unrelated environmental effect.
This paper evaluates the performance of asphalt membranes by examining the chemical and permeability changes experienced by the asphalt during aging tests. The aging process was accelerated by exposing the asphalt to elevated temperatures, high oxygen concentrations, and increased strengths of aqueous oxidizing agents. The synergistic effects of the variables are evaluated by using a fractional factorial experimental design. The installation costs for a catalytically airblown asphalt liner are roughly half that of the typical polymeric materials, and also less than the rubberized asphalt membrane. The results of the initial accelerated aging tests of the asphalt membranes indicate that this material will provide stable, long-term leachate isolation in a mill tailings environment.
It is necessary to identify those measurable soil parameters which dictate the severity of the corrosion problem for coated irons and steels. When this is done, meaningful accelerated aging tests can be designed to validate the reduced corrosion rate for the planned coating. The following discussion introduces the important concepts and measurement parameters in the (a) design of accelerated aging tests, and (b) evaluation of the planned installation site for corrosion potential. Certain combinations of soil oxidation reduction potential (ORP) or electric potential (Eh), acidity (pH), fertilizer, water table, and soil hydraulic conductivity can result in severe corrosion of buried steel/iron vessels. If there are power lines nearby, additional loss of vessel material to the soil will occur. These factors are discussed.
Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.
Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.
Pain is necessary for survival but chronic pain is disabling and causes significant health and economic problems. This study provides an understanding of the future for spinal cord stimulation. Stimulation by means of chronically implanted electrodes, was carried out in 200 patients with pain of varied benign organic etiology. In 177 of them, pain was confined to the failed back syndrome. Most patients were referred by a Pain Management Service. 226 epidural implants were used: 80 unipolar, 59 Resume, 12 bipolar, and 75 quadripolar. Patients were followed for periods of 6 months to 12 years, with a mean follow-up of 44 months. 84 patients (42%) were able to control their pain by stimulation alone, 22 patients (11%) needed occasional analgesic supplements along with their stimulation program. Pain secondary to failed back syndrome, multiple sclerosis, peripheral vascular disease, sympathetic dystrophy and diabetic neuropathy responded favorably. Pain due to cauda equina injury, ...
Researchers at Lawrence Livermore National Laboratory are developing high-performance explosive firing vessels to contain (one time) explosive detonations that contain toxic metals and hazardous gases. The filament-wound polymer composite vessels are designed to contain up to 80 lb (TNT equivalent) explosive in a 2-meter sphere without leakage. So far, two half-scale (1-meter diameter) vessels have been tested; one up to 150% of the design explosive limit. Peak dynamic pressures in excess of 280 MPa (40 Ksi) in the vessel were calculated and measured. Results indicated that there was a small amount of gas and particle leakage past the first two of the seven o-ring seals. However, the remaining five seals prevented any transient leakage of the toxic gases and particulates out of the vessel. These results were later confirmed by visual inspection and particulate analysis of swipes taken from the sealing surfaces.
Several nuclear power plant sites have been wounded in the crossfire between two distinct corporate cultures. The traditional utility culture lies on one side and that of the nuclear navy on the other. The two corporate cultures lead to different perceptions of open-quotes safety culture.close quotes This clash of safety cultures obscures a very important point about nuclear plant operations: Safety depends on organizational learning. Organizational learning provides the foundation for a perception of safety culture that transcends the conflict between utility and nuclear navy cultures. Corporate culture may be defined as the knowledge, attitudes, and beliefs shared by employees of a given company. Safety culture is the part of corporate culture concerning shared attitudes and beliefs affecting individual or public safety. If the safety culture promotes behaviors that lead to greater safety, employees will tend to open-quotes do the right thingclose quotes even ...
A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight section was assembled and tested. This paper summarizes the status of ...
We performed histological examination of 69 samples of Acropora sp. manifesting different types of tissue loss (Acropora White Syndrome-AWS) from Hawaii, Johnston Atoll and American Samoa between 2002 and 2006. Gross lesions of tissue loss were observed and classified as diffuse acute, diffuse subacute, and focal to multifocal acute to subacute. Corals with acute tissue loss manifested microscopic evidence of necrosis sometimes associated with ciliates, helminths, fungi, algae, sponges, or cyanobacteria whereas those with subacute tissue loss manifested mainly wound repair. Gross lesions of AWS have multiple different changes at the microscopic level some of which involve various microorganisms and metazoa. Elucidating this disease will require, among other things, monitoring lesions over time to determine the pathogenesis of AWS and the potential role of tissue-associated microorganisms in the genesis of tissue loss. Attempts to experimentally induce AWS should ...
A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical NO-detector at variable gas flows. Correlations ...
Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeV electrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. Clinical and technical aspects of treatment are presented along ...
BACKGROUND: Although definitions vary, infected nonunion has been defined as a state of failure of union and persistence of infection at the fracture site for 6 to 8 months.>). Infected nonunions of the supracondylar region of the femur are uncommon and are mostly due to a severe open fracture with extensive comminution and segmental bone loss or after internal fixation of a comminuted closed fracture. Associated factors include exposed bone devoid of vascularized periosteal coverage for more than 6 weeks, purulent discharge, a positive bacteriological culture from the depth of the wound, and histologic evidence of necrotic bone containing empty lacunae. Soft-tissue loss with multiple sinuses, osteomyelitis, osteopenia, complex deformities with limb-length inequality, stiffness of the adjacent joint, polybacterial multidrug-resistant infection, and smoking all complicate treatment and recovery. Although uncommon in incidence, infected nonunions of the long bones ...
Bone matrix gelatin, prepared by sequential chemical treatment including decalcification with 0.6 N hydrochloric acid [9], was used as an alloimplant for the treatment of benign bone tumours, tumorous conditions of bone, acetabular dysplasia, delayed union, traumatic bone defects and other disorders. The bone matrix gelatin implanted into bone defects was incorporated successfully in 98% of implantations, excluding cases of infection, tumour recurrence and recurrence of tumorous conditions. The material was also implanted into ten bone sites as an onlay but in five it was resorbed without new bone formation. The incorporation of the bone matrix gelatin into the recipient bed was completed from 6 to 33 months (average 14.9 months) after implantation. Wound infection complicated 5 of 165 implantations (3%) in previously uninfected sites. Low grade fever persisting after the tenth post-operative day (a probable sign of immunological reaction) occurred in 4 of 160 ...
The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts containing circulating cooling fluid to cool the windings; polymer ...
There is a plethora of new silver-containing dressings on the market today. Various manufacturers attempt to show that their dressings are the most efficacious and therefore should be preferentially employed by health care workers based on the results of their in vitro tests. However, there have been no studies that clearly identify which tests are appropriate for comparison purposes. The purpose of this study was to determine which in vitro test is most appropriate for evaluating the antimicrobial efficacy of silver-containing dressings. This was done by testing seven silver-containing dressings and two non-silver-containing topical agents against 17 clinically relevant microorganisms using zone of inhibition assays and time-kill kinetic assays in complex media. The results for the two assays were then correlated to determine whether the methods generated similar results. It was determined that the two methods do not correlate at all. This is most likely a result of the silver ...
The massive stars in the Galactic center inner arcsecond share analogous properties with the so-called Hot Jupiters. Most of these young stars have highly eccentric orbits, and were probably not formed in-situ. It has been proposed that these stars acquired their current orbits from the tidal disruption of compact massive binaries scattered toward the proximity of the central supermassive black hole. Assuming a binary star formed in a thin gaseous disk beyond 0.1 pc from the central object, we investigate the relevance of disk-satellite interactions to harden the binding energy of the binary, and to drive its inward migration. A massive, equal-mass binary star is found to become more tightly wound as it migrates inwards toward the central black hole. The migration timescale is very similar to that of a single-star satellite of the same mass. The binary's hardening is caused by the formation of spiral tails lagging the stars inside the binary's Hill radius. We show ...
The ability to feed on vertebrate blood has evolved many times in various arthropod clades. Each time this trait evolves, novel solutions to the problem posed by vertebrate hemostasis are generated. Consequently, saliva of blood-feeding arthropods has proven to be a rich source of antihemostatic molecules. Vasodilators include nitrophorins (nitric oxide storage and transport heme proteins), a variety of peptides that mimic endogenous vasodilatory neuropeptides, and proteins that catabolize or sequester endogenous vasoconstrictors. A variety of platelet aggregation inhibitors antagonize platelet responses to wound-generated signals, including ADP, thrombin, and collagen. Anticoagulants disrupt elements of both the intrinsic and extrinsic pathways. Molecular approaches (termed 'sialomics') to characterize the full inventory of mRNAs transcribed in salivary glands have revealed a surprising level of complexity within a single species. Multiple salivary proteins may be ...
AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides several capabilities like performing calculations using modified Human Respiratory Tract Model parameters for the mechanical ...
The Two-Beam Accelerator (TBA) consists of a long high-gradient accelerator structure (HGS) adjacent to an equal-length Free Electron Laser (FEL). In the FEL, a beam propagates through a long series of undulators. At regular intervals, waveguides couple microwave power out of the FEL into the HGS. To replenish energy given up by the FEL beam to the microwave field induction accelerator units are placed periodically along the length or the FEL. In this manner it is expected to achieve gradients of more than 250 MV/m and thus have serious option for a 1 TeV /times/ 1 TeV linear collider. The state of present theoretical understanding of the TBA is presented with particular emphasis upon operation of the ''steady-state'' FEL, phase and amplitude control of the rf wave, and suppression of sideband instabilities. Experimental work has focused upon the development of a suitable HGS and the ...
The Fermilab Linac Upgrade is planned to increase the energy of the H- linac from 200 to 400 MeV. This is intended to reduce the incoherent space-charge tuneshift at injection into the 8 GeV Booster which can limit either the brightness or the total intensity of the beam. The Linac Upgrade will be achieved by replacing the last four 201.25 MHz drift-tube tanks which accelerate the beam from 116 to 200 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of abut 7.5 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. Each accelerator module will be driven with a klystron-based rf power supply. A prototype rf modulator has been built and tested at Fermilab, and a prototype 12 MW klystron is being fabricated by Litton Electron Devices. Fabrication of production accelerator modules is in progress. 8 figs., 4 tabs.
A review is presented of the quest for superheavy elements under the following headings - early history; physical and nuclear properties unique to superheavy elements; searches in nature; terrestrial samples; extra-terrestrial samples; and searches at accelerators. 72 references. (U.K.).
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Cytosol proteins prepared from castor bean endosperm (4-day-old) seedlings stimulate the exchange of [3H]phosphatidylethanolamine between liposomes and mitochondria. The acceleration of the...Full Text Available
A description of the FEL experiment underway at the 10 kA, 5 MeV Experimental Test Accelerator (ETA) is described. The facility has been designed to investigate the high-gain operation of an FEL.
The paper outlines the basic problems concerning creation of electron-positron linear colliders, as well as their present-day status. More details on the question can be found in the proceedings of recent workshops on linear colliders contained in the References. ((orig.)).
The stability of prothrombin and factor VII was studied using accelerated degradation tests in three preparations of freeze-dried pooled normal plasmas. In a previous report (Brozović, Gurd,...Full Text Available
This section of the report is concerned with the study of the metallisation, oxidation and doping of materials which are of importance to the micro-electronics industry. The Van de Graaff accelerator and radioactive tracers are used for studying surface and sub-surface behaviour of these materials.
The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.
When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.
Technical developments in the construction of high power accelerators have created new research activities on accelerator-driven transmutation technologies (ADTT) with main applications for energy production and nuclear waste transmutation. The on-going research was reported and discussed at the conference. The studies of energy production based on ADTT indicate possible important advantages compared to the present nuclear power reactors. Natural Uranium or Thorium is burned in a subcritical reactor with or without simultaneous incineration and transmutation of nuclear waste. High level radioactive wastes and weapons Plutonium constitute an environmental and proliferation problem. Studies were reported on the possibilities to use ADTT to considerably shorten the life-time and reduce the amount of long-lived radioactive waste in order to decrease the volumes needed for long-term geologic deposition. A panel discussed the ADTT impact on nuclear ...
The principal paradigm for gamma-ray bursts (GRBs) suggests that the prompt transient gamma-ray signal arises from multiple shocks internal to the relativistic expansion. This paper explores how GRB prompt emission spectra can constrain electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The array of possible high-energy power-law indices in accelerated populations is highlighted, focusing on how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. When encompassing the MeV-band spectral break, fits to BATSE/EGRET burst data indicate that the preponderance of electrons responsible for the prompt emission reside in an intrinsically non-thermal population. This differs markedly from typical populations generated in acceleration simulations; potential resolutions of this conflict such as the action ...
It has been discovered that iron(III) chloride complexes supported on activated charcoal oxidize phosphine under normal conditions. The process accelerates as the concentration of the chloride ions and the proton acid increases.
The discussion of energy usage falls naturally into three parts. The first is a review of what the problem is, the second is a description of steps that can be taken to conserve energy at existing facilities, and the third is a review of the implications of energy consumption on future facilities.
The mechanism of chemotherapy-induced acceleration of ovarian aging is not fully understood. We used doxorubicin, a widely used cancer chemotherapeutic, in a variety of in vivo xenograft,...Full Text Available
1. The mechanical power spent to accelerate the limbs relative to the trunk in level walking and running, Ẇint, has been measured at various `constant' speeds (3-33...Full Text Available
Obesity and metabolic syndrome result from excess calorie intake and genetic predisposition and are mechanistically linked to type II diabetes and accelerated body aging; abnormal nutrient and insulin...Full Text Available
The non-thermal supernova remnant RX J1713.7-3946 (G347.3-0.5) has recently been shown to be a site of cosmic ray (CR) electron acceleration to TeV energies (Muraishi et al. 2000). Here we present evidence that this remnant is also accelerating CR nuclei. Such nuclei can interact with ambient interstellar gas to produce high energy gamma-rays via the decay of neutral pions. We associate the unidentified EGRET GeV gamma- ray source 3EG J1714-3857 with a massive (~3*10 5 Mo) and dense (~500 nucleons cm -3) molecular cloud interacting with RX J1713.7-3946. Direct evidence for such interaction is provided by observations of the lowest two rotational transitions of CO in the cloud; as in other clear cases of interaction, the CO(J=2-1)/CO(J=1-0) ratio is significantly enhanced. Since the cloud is of low radio and X-ray brightness, CR electrons cannot be responsible for the bulk of its GeV emission there. A picture thus emerges where both electrons ...
Nuclear physics accelerators are powered by microwaves which must travel in waveguides between room-temperature sources and the cryogenic accelerator structures. The ohmic heat load from the microwaves is affected by the temperature-dependent surface resistance and in turn affects the cryogenic thermal conduction problem. Integrated EM & thermal analysis of this difficult non-linear problem is now possible with the VORPAL finite-difference time-domain simulation tool. We highlight thermal benchmarking work with a complex HOM feed-through geometry, done in collaboration with researchers at the Thomas Jefferson National Accelerator Laboratory, and discuss upcoming design studies with this emerging tool. This work is part of an effort to generalize the VORPAL framework to include generalized PDE capabilities, for wider multi-physics capabilities in the accelerator, vacuum electronics, plasma processing ...
Oxidative stress has been implicated in the etiology of age-related muscle loss (sarcopenia). However, the underlying mechanisms by which oxidative stress contributes to sarcopenia have not been thoroughly...Full Text Available
Hyperglycemia and hyperinsulinemia accelerate both aging and cancer. Antidiabetic biguanides such as metformin decrease glucose, insulin and IGF-1 level. Metformin increases lifespan and prevents cancer...Full Text Available
Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number density of UHECR ...
The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available
The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By smoothing the axial magnetic field profile in the accelerator ...
Physics and technology of free electron laser (FEL) are reviewed. Mechanisms of stimulated emission in FEL and its present status and future prospects are presented. Electromagnetic wiggler, two stage FEL and so on are also interpreted. Finally, accelerators and wigglers for FEL, recent FEL experiments and FEL applications are noted. (author).
The head of KEK expressed his dismay that SLAC has entered into a collaboration with 3 other US labs and proposes to build the next linear collider at Fermilab, Ilinois. KEK wants the next accelerator to be built somewhere in the Asian Pacific region (1 page).
The development of structural barriers for nuclear waste packages involves selection of candidate materials, their screening by mechanical and corrosion testing, rigorous accelerated testing, and evaluation and comparison with other package elements. This document presents results from work conducted on titanium and ferrous alloys.
The Los Alamos FEL requires tight control of the amplitudes and phases of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. This paper describes the accelerator control scheme and our model and discusses the control of noise in feedback loops, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes are shown and ...
Following a brief description of the SSC, the computing needs are discussed for both the accelerator design and the experimentation. The computing power required is considerably beyond that being used at present facilities, and parallel processing is expected to play an important role in supplying these needs.
In general, over the course of the time, the phenomenon of acceleration in physical development may be observed, i.e. the children and adults of the next generation are taller and heavier than in former generation. Our data presented in this paper show a regular trend of acceleration in the development on Vietnamese, but the trend is still slow and was mostly probably influenced by our difficulties in a long time of war. It is hoped that, the acceleration in the development may be increased in the future following the economical acceleration of our country, however it is known that the ratio between the length of different parts of human body is a specific characteristic for human race, sex and group age. Therefore we may estimate these ratio for the prolongation of the utilization of our measured physical data. The result of studies on water balance of Vietnamese living in comfortable environment air ...
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
The last of our series on the Task Forces. PS accelerator 'We had a clear mandate, which we could approach in a logical way', explains Steve Myers, Head of SL Division and convenor of Task Force 5, 'To avoid duplication of effort in the accelerator sector through a restructuring that would lead to greater efficiency and flexibility and so release resources for the LHC.' The implementation of all their recommendations is already underway, albeit with different time scales. In 2001 the accelerator sector involved more than 900 staff members in three divisions (LHC, PS and SL) and one unit (AC), working in 141 sections within 34 groups. The first step for the Task Force was to identify major activities within the sector and to set up inter-divisional working groups to review these activities (16 in all), identifying the technologies and the numbers of staff associated with each activity. The working groups were also asked ...
The honeybee has been the most important insect species for study of social behavior. The recently released draft genomic sequence for the bee will accelerate honeybee behavioral genetics. Although...Full Text Available
The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The results show that ...
Accelerated oxidation treatment technology is introduced for use in the treatment of poor quality water by ozone injected from the bottom of a pressurized ozone contact tank. Under study as oxidation accelerating processes using ozone center about an ozone/hydrogen peroxide treatment, ozone/UV treatment, ozone/hydrogen peroxide/UV treatment, etc. As the result of testing, important respects in accelerated oxidation are learned, which are stated below. In the ozone-aided treatment, there are some substances, such as chromatic matters, that can be removed more rapidly when in direct contact with gaseous ozone. In this case, the concentration of remnant ozone poses an important problem. In relation to the amount of injected hydrogen peroxide, what is important is the ozone/hydrogen peroxide injection ratio relative to the substance that is to be removed. In the use of UV rays, since the decomposition rate of dissolved ozone is ...
...global warming problem became undeniable ...as global warming are a number also review they world energy ...global warming temperatures on the models and people take what's called ...? story combat global warming conservation ...
Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety of test conditions, including temperature, aging time, and oxygen availability. These six test fuels were purposely chosen to ...
Biological membranes are lamellar structures composed of two leaflets capable of supporting different mechanical stresses. Stress differences between leaflets were generated during micromechanical experiments...Full Text Available
Based on preliminary studies, some conclusions can be drawn concerning the Accelerator Fuel Enricher and Fission Product Exterminator (APEX). APEX-1 and APEX-2 systems can destroy TU's, /sup 137/Cs, and /sup 90/Sr at acceptable cost and efficiency. The principal difference between APEX-1 and APEX-2 is the in-reactor and in-circuit inventory of /sup 137/Cs and /sup 90/Sr. Stable and low hazard wastes can be disposed of by burial. Accelerator breeders can effectively sustain a fission reactor economy indefinitely. Military waste can be blended into commercial fuel cycle for transmutation. Accelerator and target technologies appear practical and could be developed in a few years. More detailed studies are needed to better define the technical and economic features of the LAFER and APEX cycles, so that comparative assessments can be made between these cycles, as well as with other transmutation and waste disposal ...
The existence and importance of an accelerated adjacent segment disc degeneration (ASD) after lumbar fusion have previously not been demonstrated by RCTs. The objectives of this study were, to determine...Full Text Available
Frontotemporal lobar degeneration is a progressive neurodegenerative syndrome that is the second most common cause of early-onset dementia. Mutations in the progranulin gene are a major cause of familial...Full Text Available
The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.
Within about 10 years, microelectronic devices will be made with more than a billion (10"9) electronic components per chip. To implement such a sophisticated technology it will be essential to have a fundamental understanding of the solid state interaction between the different materials in thin film semiconductor structures. This is the main purpose of this research program. Characterization and analysis is carried out mainly by Rutherford backscattering spectrometry and channelling using accelerated nuclear particles from the Van de Graaff accelerator, while radioactive isotopes provide information about interaction mechanisms. 6 figs., 1 ref.
Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.
We perform a detailed phase-space analysis of various phantom cosmological models, where the dark energy sector interacts with the dark matter one. We examine whether there exist late-time scaling attractors, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. We find that all the examined models, although accepting stable late-time accelerated solutions, cannot alleviate the coincidence problem, unless one imposes a form of fine-tuning in the model parameters. It seems that interacting phantom cosmology cannot fulfill the basic requirement that led to its construction.
We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.
The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.
Closing and breaking of current in microsecond megaampere plasma opening switches are considered. Conductivity current scaling in the switch due to plasma acceleration by a magnetic piston is discussed and compared with experimental data. Two ways of determining the width of a current channel are taken up. This channel results from the diffusion of the magnetic field in the plane of the piston followed by the convective ejection of the field frozen in the accelerated plasma flow behind the shock wave into the bridge. Based on experimental data, a scaling law for the voltage on the switch according to the switch parameters is derived. The problem of reverse closing, which limits the efficiency of storage energy extraction into the load, is considered
The summary of this report is: (1) The range of scales #LAMBDA# of a system is not a Lorentz invariant and can vary greatly for some systems. (2) There exists an optimum frame which minimizes #LAMBDA#. (3) We demonstrated speedup of x1000 for PIC simulation of relativistic beam interacting with electron background. (4) It is not in contradiction with the conventional scientific wisdom that 'complexity' is an invariant. (5) We identified three domains of application (laser-plasma acceleration, e-cloud in HEP accelerators, free electron lasers) for which speedup ranging from 2 to 4 orders of magnitude were demonstrated on toy problems.
A calculation on the stabilization of the sideband instability in the free electron laser (FEL) and inverse FEL (IFEL) was completed. The issue arises in connection with the use of a tapered (''variable-parameter'') undulator of extended length, such as might be used in an ''enhanced efficiency'' traveling-wave FEL or an IFEL accelerator. In addition, the FEL facility at Columbia was configured as a traveling wave amplifier for a 10-kW signal from a 24-GHz magnetron. The space charge field in the bunches of the FEL was measured. Completed work has been published.
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.
The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.
This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process.
In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.
A feasibility on the development of a high energy proton accelerator to be used for R and D in the nuclear field of korea was studied. The proposed one is a proton linac with parameters of about 1 GeV, 20 mA which can supply enough neutrons by the spallation reaction to drive a subcritical reactor. It= is expected to solve the intrinsic problem in the nuclear field such as safety, nuclear waste, proliferation and resource. The study was carried out through a multi-institutional cooperation of universities, institute and industry for a national consensus. 5 refs., 8 tabs., 8 figs. (author)
The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.
The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).
The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.
We provide a both qualitative and quantitative comparison among different approaches aimed to solve the problem of non-linear diffusive acceleration of particles at shocks. In particular, we show that state-of-the-art models (numerical, Monte Carlo and semi-analytical), even if based on different physical assumptions and implementations, for typical environmental parameters lead to very consistent results in terms of shock hydrodynamics, cosmic ray spectrum and also escaping flux spectrum and anisotropy. Strong points and limits of each approach are also discussed, as a function of the problem one wants to study.
To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.
A discrete time control algorithm using the damped least squares is introduced for acceleration and energy exchange controls in nonlinear vibrating systems. It is shown that the damping constant of least squares and sampling time step of the controller must be inversely related to insure that vanishing the time step has little effect on the results. The algorithm is illustrated on two linearly coupled Duffing oscillators near the 1:1 internal resonance. In particular, it is shown that varying the dissipation ratio of one of the two oscillators can significantly suppress the nonlinear beat phenomenon.
We develop methods for accelerating metric similarity search that are effective on modern hardware. Our algorithms factor into easily parallelizable components, making them simple to deploy and efficient on multicore CPUs and GPUs. Despite the simple structure of our algorithms, their search performance is provably sublinear in the size of the database, with a factor dependent only on its intrinsic dimensionality. We demonstrate that our methods provide substantial speedups on a range of datasets and hardware platforms. In particular, we present results on a 48-core server machine, on graphics hardware, and on a multicore desktop.
Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.
Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.
This study was composed of three parts: a post cure study to optimize final properties of an ethylene-propylene-diene (EPDM) formulation, an accelerated aging study to compare the stress relaxation behavior of a butyl and an EPDM elastomer under compression, and a cursory evaluation of a new 70 Shore A EPDM. The optimum postcure for the EPDM was found to be 2 to 4 hours at 182{degrees}C in a vacuum. The EPDM was also shown to have superior aging characteristics compared to the butyl and is recommended for use instead of the butyl material. The physical properties for new 70 Shore A EPDM are satisfactory, and the stress relaxation behavior was only slightly inferior to the other EPDM.
A computer model of an electrothermal accelerator has been developed which applies to the plasma generator as well as the gun barrel, and it for the first time allows study of the interdependent physical processes in both components simultaneously. The code comprises a 2D transient description of the plasma arc, a 2D, two-phase interior ballistics module, and a preprocessor delivering the required plasma physical data. Some results on the flow field, pressure and temperature in a typical accelerator are presented, and probable limitations on the performance of such a system are discussed. The code is to be applied to different concepts of electrothermal chemical guns.
Mass shift of accelerated charges-sources of a massive vector and massive scalar fields, are considered in an approximation which is classical with respect to the charge motion but quantum with respect to their interaction with their proper field. For uniformly accelerated charges the mass shifts are expressed in terms of cylindrical functions of the quantum parameter ..mu..c/sup 3//h/2..pi..w/sub 0/ which is the ratio of the mass ..mu.. of the proper field quanta to the charge acceleration w/sub 0/. For finite positive values of the parameter both the imaginary and real parts of the shifts are nonvanishing and negative. For ..mu -->..0 the real part of the mass shift of a vector charge tends to the classical value -..cap alpha..h/2..pi..w/sub 0//2c/sup 3/ obtained earlier, thereas that of the scalar charge tends to zero. These and other properties of the shifts as functions of ..mu.. are studied by taking into account ...
This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and results on emittance ...
Atterberg limits, free swell, and hydraulic conductivity tests were conducted to assess how wet-dry cycling affects the plasticity and swell of bentonite, and the hydraulic conductivity of geosynthetic clay liners (GCLs) hydrated with deionized (DI) water (pH 6.5), tap water (pH 6.8), and 0.0125-M CaCl{sub 2} solution (pH 6.2). The plasticity of bentonite hydrated with DI water increased during each wetting cycle, whereas the plasticity of bentonite hydrated with tap water and CaCl{sub 2} decreased during each wetting cycle. Wet-dry cycling in DI water and tap water had little effect on swelling of the bentonite, even after seven wet-dry cycles. However, swelling decreased dramatically after two wetting cycles with CaCl{sub 2} solution. Hydraulic conductivity of GCL specimens remained low during the first four wetting cycles ({approximately}1 x 10{sup {minus}9} cm/s). However, within five to eight cycles, the hydraulic conductivity of all specimens permeated with the 0.0125-M CaCl{sub ...
We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. The increase of the current with the gamma radiation dose may be attributed partly to ...
The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the ...
The purpose of the Microelectronic Evaluation Laboratory at Sandia is to develop a program for evaluating CMOS LSI (complementary metal oxide silicon - large scale integrated) technology devices which are being used for the first time in a weapon system. These evaluations are based on accelerated aging studies and electrical tests to determine the reliability and life of the devices. In accelerated aging, specific, controlled stresses are applied to the device to accelerate time-to-failure. Data are used tin mathematical models to estimate life in acutal use. The stresses used for this technology are temperature and voltage. The devices are stored at temperatures with or without voltage applied (steady-state or cyclical) and periodically tested until at least 50% failures are encountered. Since most current technologies use epoxy-die-attachment, aging temperatures must be under 200/sup 0/C. This delays device failure, and a ...
The strong coupling of subsystem elements, such as the accelerator, wiggler, and optics, greatly complicates the understanding and design of a free electron laser (FEL), even at the conceptual level. To address the strong coupling character of the FEL the concept of an Integrated Numerical Experiment (INEX) was proposed. Unique features of the INEX approach are consistency and numerical equivalence of experimental diagnostics. The equivalent numerical diagnostics mitigates the major problem of misinterpretation that often occurs when theoretical and experimental data are compared. The INEX approach has been applied to a large number of accelerator and FEL experiments. Overall, the agreement between INEX and the experiments is very good. Despite the success of INEX, the approach is difficult to apply to trade-off and initial design studies because of the significant manpower and computational requirements. On the other hand, INEX provides a base ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...
A working visit was made to the National Laboratory for High Energy Physics, Tsukuba, Japan, during the time periods May 16, 1988--June 15, 1988 for the purposes of further evaluation of the high intensity plasma sputter negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams. During the visit, the traveler worked in collaboration with Japanese scientists in installing and testing of the source on the University of Tsukuba tandem electrostatic accelerator injector. During the course of preliminary testing of the ion source and prior to actual injection into the accelerator, sparking began in one or more tube sections, which ultimately led to the decision to replace the damaged tube sections. This problem led to postponement of the scheduled tandem accelerator tests. The traveler attended the Seventh ...
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. ...
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each ...
The Accelerator Transmutation Waste System is under development at the Los Alamos National Laboratory. The goal is to perform an independent verification of the feasibility of actinide and long-lived fission product burning in this system. The authors' work is divided into five tasks: (a) production of an actinide and long-lived fission product cross section library from JEF 2.2; (b) simulation using MCNP and KENO IV Monte Carlo codes, of the Accelerator Transmutation Waste System configurations existing in literature; (c) validation of HETC Monte Carlo code (production of spallation source); (d) validation of the cross sections by comparison of Keff and reaction rate results, calculated with MNCP and KENO IV, with experimental benchmarks and intercomparison between the authors' calculations of a PWR unit cell and the computations carried out with various codes and cross section libraries (NEACRP critically group data); and (e) simulation of ...
A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A new test facility is being built at CERN for this purpose with ...
The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s ...
We analytically work out the orbital effects caused by a Rindlertype extra-acceleration ARin which naturally arises in some recent models of modified gravity at large distances. In particular, we focus on the perturbations induced by it on the two-body range {\\rho} and range-rate {\\rho}\\cdot which are commonly used in satellite and planetary investigations as primary observable quantities. The constraints obtained for ARin by comparing our calculations with the currently available range and range-rate residuals for some of the major bodies of the solar system, obtained without explicitly modeling ARin, are 1 - 2 \\times 10-13 m s-2 (Mercury and Venus), 1 \\times 10-14 m s-2 (Saturn), 1 \\times 10-15 m s-2 (Mars), while for a terrestrial Rindler acceleration we have 5 \\times 10-16 m s-2 (Moon). Another approach which could be followed consists of taking into account ARin in re-processing all the available data sets with accordingly modified ...
Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion beams have been developed. Large plasma sources, the method of generating negative ions and the extraction of ...
Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with ...
This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP Division, which led to the loss of a large number of key people to positions elsewhere in the Laboratory. ...
ObjectivesThe overall scientific aim of this project is, through development of an appropriate numerical modelling tool, to identify and investigate the mechanisms that control the current observed rapid thinning and acceleration of Greenland outlet glaciers and to investigate their likely future behaviour in the context of climate warming. This aim is addressed through the four major specific objectives below. These objectives build on each and therefore the order of priority is driven by the order in wh [continued...]DescriptionCurrently, the Greenland ice sheet is undergoing rapid changes in the coastal regions which have been attributed to a general warming trend to the regions climate over the last decade. Several of the narrow and fast flowing outlet glaciers that drain the ice sheet into the sea are observed to have accelerated their flow and thinned. For instance, Jakobshavn Isbrae on the West coast of Greenland has almost doubled its ...
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and ...
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and ...
The paper presents the investigations of plasma streams generated by pulsed plasma gun 'Prosvet' operated with different gases: krypton (m=84) and helium (m=4). Contour parameters of working gas spectral lines (full intensities and half-widths) are used for determination of spatial distributions of the electron density and temperature. Temporal distributions of the spectral lines intensities (both neutrals and ions of working gas), impurity spectral lines and continuum intensities are analyzed. Plasma stream velocity was estimated by time-of-flight method between two monochromators (MUM) connected with photo-multiplier. longitudinal distributions of the plasma pressure for different time moments and varied distances from the accelerator output have been used for investigation of the plasma stream dynamics and study the plasma compression in the focus region for different operational regimes of plasma accelerator. Experiments show that operation ...
The present report addresses several aspects of the free electron laser (FEL) and accelerator, including their features, potentials, mechanisms, beams emitted from undulator, FEL produced by helical mangnetic field, major problems with FEL, etc. In FEL, relativistic electron beams interact with an electromagnetic field with periodically changing intensity to produce coherent electromagnetic waves with variable wavelength. The capability of varying its wavelength represents the greatest advantage over conventional lasers. Any periodic magnetic field can serve as a wiggler. A wiggler can be used both in an amplifier and oscillator. A periodic magnetic field used may be either of a parallel type or of a helical type. The polarization of emitted beams depends on the shape of the magnet regardless of whether its field is parallel or helical. An equation is derived in the report which expresses the wavelength of an electromagnetic wave produced by an undulator. An ...
Elise is a heavy ion induction linear accelerator that will demonstrate beam manipulations required in a driver for inertial fusion energy. With a line charge density similar to that of heavy ion drivers, Elise will accelerate a #>=# 1 gs beam pulse of K"+ ions from an initial energy of 2 MeV to a final energy #>=# 5 MeV. In the present design, the Elise electrostatic quadrupoles (ESQ) will have a 2.33 cm radius aperture operating at #+-#59 kV. The half-lattice periods range from 21 cm to 31 cm. The entire machine will be approximately 30 m long, half of that is the induction accelerator and the remaining half is the injector (including the Marx generator) and the matching section. Elise will be built in a way that allows future expansion into the full ILSE configuration, therefore it will have an array of four ESQ focusing channels capable of transporting up to a total of 3.2 A of beam current. Elise will also have ...
It is well known that the solubilization of coal can be accelerated by adding sulfur or hydrogen sulfide during direct liquefaction of difficult coals. From the studies of authors on the coal liquefaction under the conditions at rather low temperatures between 300 and 400{degree}C, liquefaction products with high quality can be obtained by suppressing the aromatization of naphthene rings, but it was a problem that the reaction rate is slow. For improving this point, results obtained by changing solvents have been reported. In this study, to accelerate the liquefaction reaction, Illinois No.6 coal was liquefied in tetralin at temperature range from 300 to 400{degree}C by adding a given amount of sulfur or hydrogen sulfide at the initial stage of liquefaction. The addition of sulfur or hydrogen sulfide provided an acceleration effect of liquefaction reaction at temperature range between 300 and 400{degree}C. The addition of ...
A Bragg waveguide consisting of multiple dielectric layers with alternating index of refraction becomes an excellent option to form electron accelerating structure powered by high power laser sources. It provides confinement of a synchronous speed-of-light mode with extremely low loss. However, laser field can not be coupled into the structure collinearly with the electron beam. There are three requirements in designing input coupler for a Bragg electron accelerator: side-coupling, selective mode excitation, and high coupling efficiency. We present a side coupling scheme using a distributed grating-assisted coupler to inject the laser power into the waveguide. Side coupling is achieved by a grating with a period on the order of an optical wavelength. The phase matching condition results in resonance coupling thus providing selective mode excitation capability. The coupling efficiency is limited by profile matching between the outgoing beam and ...
In this paper the authors present a design study on the longitudinal dynamics of a relativistic klystron two-beam accelerator (RK-TBA) scheme which has been proposed as a power source candidate for a 1 TeV next linear collider (NLC). They address the issue of maintaining stable power output at desired level for a 300-m long TBA with 150 extraction cavities and present their simulation results to demonstrate that it can be achieved by inductively detuning the extraction cavities to counter the space charge debunching effect on the drive beam. They then carry out simulation study to show that the beam bunches desired by the RK-TBA can be efficiently obtained by first chopping an initially uniform beam of low energy into a train of beam bunches with modest longitudinal dimension and then using the open-quotes adiabatic captureclose quotes scheme to bunch and accelerate these beam bunches into tight bunches at the operating energy of the drive ...
The fundamental mechanisms underlying the chemical degradation of polymers can change as a function of environmental stress level. When this occurs, it greatly complicates any attempt to use accelerated tests for predicting long-term material degradation behaviors. Understanding how degradation mechanisms can change at different stress levels facilitates both the design and the interpretation of aging tests. Oxidative degradation is a predominant mechanism for many polymers exposed to a variety of different environments in the presence of air, and there are two mechanistic considerations which are widely applicable to material oxidation. One involves a physical process, oxygen diffusion, as a rate-limiting step. This mechanism can predominate at high stress levels. The second is a chemical process, the time-dependent decomposition of peroxide species. This leads to chain branching and can become a rate-controlling factor at lower stress levels involving time-scales ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is ...
We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER, which stands for "Coupled-cavity Linac USing Transverse Electric Radial field". In order to compare the performance of this structure with other hadrontherapy linac designs involving high frequencies, a conceptual study has been performed for an operating frequency of 3 GHz. Moreover a proof of principle has been obtained through RF measurements on a prototype operating at 1 GHz. An accelerator complex using a CLUSTER linac is also considered for protontherapy purposes. The whole complex is called cyclinac and is composed of a ...
In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating ...
Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of ...
The deactivation rate of a resid hydrotreating catalyst is determined by a complex set of factors involving both chemical and physical changes in the catalyst structure. The various chemical changes that are associated with resid conversion involve thermal and catalytic steps of relatively large molecular weight species with the overall rates significantly affected by mass transfer limitations. The deposition of coke and the variation in the effective promoter level by the accumulation of metals deposited from the resid are the principal factors governing deactivation. The relative importance of mass transfer restrictions on activity and catalyst deactivation can be observed in studies where the average pore diameter of the catalyst has been varied. Several models have been proposed to characterize the deactivation of resid hydroprocessing catalysts. In this paper, the authors discuss some accelerated aging tests with a relatively large pore commercial ...
This document describes the results of accelerated aging tests to determine the long-term effectiveness of selected impoundment liner materials in a uranium mill tailings environment. The study was sponsored by the US Department of Energy under the Uranium Mill Tailings Remedial Action Project. The study was designed to evaluate the need for, and the performance of, several candidate liners for isolating mill tailings leachate in conformance with proposed Environmental Protection Agency and Nuclear Regulatory Commission requirements. The liners were subjected to conditions known to accelerate the degradation mechanisms of the various liners. Also, a test environment was maintained that modeled the expected conditions at a mill tailings impoundment, including ground subsidence and the weight loading of tailings on the liners. A comparison of installation costs was also performed for the candidate liners. The laboratory testing and cost ...
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault ...
The observation that Type Ia supernovae are fainter than expected given their red shifts has led to the conclusion that the expansion of the universe is accelerating. The widely accepted hypothesis is that this acceleration is caused by a cosmological constant or, more generally, some dark energy field that pervades the universe. This hypothesis presents a challenge to physics so severe that one is motivated to explore alternative explanations. In this paper, we explore whether the data from Type Ia supernovae can be explained with an idea that is almost as old as that of the cosmological constant, namely, that the strength of gravity varies on a cosmic timescale. This topic is an ideal one for investigation by an undergraduate physics major because the entire chain of reasoning from models to data analysis is well within the mathematical and conceptual sophistication of a motivated undergraduate.
Diesel passenger car is superior to gasoline engine car in the fuel economy, but it has some defects to improve: noise, startability, particulate and transient performance, etc. Among these problems, this paper presents particularly transient performance in a diesel engine and clarifies the causes of its decline at lower temperature operation. As the results, it is found that the transient torque at the early stage of acceleration is only 50% at -20/sup 0/C, and that when coolant temperature went up to 20/sup 0/C, the transient torque approaches to that of the warmed up engine. The transient response become worse with retarding the injection timing and with decreasing the engine speed. On the other hand, since the normal response is not obtained despite using high cetane number fuel, main cause of the inferior transient torque is not the poor combustion, but the increase of friction or cooling loss.
We present a HST/STIS spectroscopic and optical/radio imaging study of the Seyfert NGC 2110 aiming to measure the dynamics and understand the nature of the nuclear outflow in the galaxy. Previous HST studies have revealed the presence of a linear structure in the Narrow-Line Region (NLR) aligned with the radio jet. We show that this structure is strongly accelerated, probably by the jet, but is unlikely to be entrained in the jet flow. The ionisation properties of this structure are consistent with photoionisation of dusty, dense gas by the active nucleus. We present a plausible geometrical model for the NLR, bringing together various components of the nuclear environment of the galaxy. We highlight the importance of the circum-nuclear disc in determining the appearance of the emission line gas and the morphology of the jet. From the dynamics of the emission line gas, we place constraints on the accelerating mechanism of the outflow and discuss ...
The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.
We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.
In this paper the availability and properties of radioisotopes for both radioimmunodiagnosis (RAID) and radioimmunotherapy (RAIT) are discussed. Examples are provided for radioisotopes available via direct production in nuclear reactors and accelerators or as daughters obtained from radionuclide generator systems whose parents are either reactor or accelerator produced. Important factors which must be considered for the use of a particular radioisotope include availability, the physical half-life and decay properties, and chemical versatility for protein attachment. Although both direct'' and indirect'' methods are available for attachment of radioisotopes to antibodies, this broad field of research is not reviewed in detail. Practical issues related to the availability and use of a variety of radionuclides are described. 47 refs., 5 tabs.
We use the semi-classical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the non-relativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be non-local in time in contrast to the classical approximation.
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)
The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)
To investigate the origin and nature of inertia, we introduce a new concept of hypothetical 2D, so-called, "master-space" (MS), subject to certain rules. The MS, embedded in the background 4D-spacetime, is an indispensable individual companion to the particle of interest, without relation to every other particle. We argue that a deformation/(distortion of local internal properties) of MS is the origin of inertia. With this perspective in sight, we construct the alternative relativistic theory of inertia (RTI), which allows to compute the relativistic inertial force acting on an arbitrary point-like observer due to its "absolute acceleration". We go beyond the hypothesis of locality with an emphasis on distortion of MS, which allows to improve essentially the standard metric and other relevant geometrical structures related to the noninertial reference frame of an arbitrary accelerated observer. We compute the inertial force exerted on the ...
Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction mode of polyester-monomer systems in wood ...
Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction mode of polyester-monomer systems in wood ...
SUMMARY We construct a new class of granular landslide models in which avalanches are simulated with large numbers of independent particles moving under the influence of topographically derived gravitational and centripetal acceleration. Concurrently, the particles suffer deceleration due to basal and dynamic friction. The novel aspect of the calculation is that complex particle-to-particle interactions, fluctuating basal contacts, and unresolved topographic roughness within and below the deforming flow are mimicked by random perturbations in along-track and cross-slope acceleration. We apply the method to the 1980 May 18 Mount Saint Helens debris avalanche by constraining the initial geometry and structure of the slide mass from geological data, and the initial failure sequence from eyewi...
At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.
Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.
The Linac Coherent Light Source [1] (LCLS) at SLAC National Accelerator Laboratory is preparing for the arrival of its first scientific users in the fall of 2009. LCLS is the world's first free-electron in the spectral range 800-8,000 eV, producing intense, sub-picosecond pulses of Xrays with very high spatial coherence. The accelerator facility has been commissioned in stages, beginning in April 2007 [2] with the injector linac and culminating in December 2008 [3] with the first transport of electrons through the complete beam path. On April 10, 2009, the LCLS Project team was rewarded for years of planning, design, construction, and checkout with a dream-come-true: as undulators were placed on the beam path one-by-one, the laser simply turned on without drama in the course of one hour [4...
The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.
Four interrelated projects are underway whose purpose is to migrate the LAMPF-PSR Accelerator Complex control systems to a system with a common set of hardware and software components. Project goals address problems in performance, maintenance and growth potential. Front-end hardware, operator interface hardware and software, computer systems, network systems and data system software are being simultaneously upgraded as part of these efforts. The efforts are being coordinated to provide for a smooth and timely migration to a client-sever model-based data acquisition and control system. An increased use of the distributed intelligence at both the front-end and operator interface is a key element of the projects. 2 refs., 2 figs.
The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.
Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.
The effect of asymmetric laser pulses on electron yield from a laser wakefield accelerator has been experimentally studied using > 10{sup 19} cm{sup -3} plasmas and a 10 TW, > 45 fs, Ti:Al{sub 2}O{sub 3} laser. Laser pulse shape was controlled through non-linear chirp with a grating pair compressor. Pulses (76 fs FWHM) with a steep rise and positive chirp were found to significantly enhance the electron yield compared to pulses with a gentle rise and negative chirp. Theory and simulation show that fast rising pulses can generate larger amplitude wakes that seed the growth of the self-modulation instability and that frequency chirp is of minimal importance for the experimental parameters.
A systematic study of the effects of environmental factors on nylon 66 and Kevlar 29 strength degradation in parachute components is being conducted at Sandia National Laboratories. It includes: (1) accelerated aging studies in air, inert environments, humidity, ozone, and smog; (2) a 25-year surveillance program of parachutes in a variety of natural climatic environments; (3) moisture absorption as a function of humidity; (4) effects of surface coatings normally applied to parachutes; and (5) development of nondestructive evaluation techniques which can be used to map mechanical properties over the entire parachute surface. The accelerated aging and moisture absorption studies show that air, humidity, and smog contribute to degradation. Chemiluminescence, gas chromatographic pyrograms, and uv spectroscopy show promise as nondestructive evaluation techniques.
Interesting developments in linear accelerators have been attained over the past 45 years. The status of linear accelerators and future possibilities are described in context of demanding applications and technology maturity. Features of industrial or `factory`-type applications are high availability, economic operations, low investment cost and ease of running a facility. All features have been demonstrated in one manner or another at large operating facilities for the research community; within a different context that has been argued in the past to be not as demanding as for `factory` installation. In addition, comments are made relative to intense beam power levels and choices that can be made for power levels below 10 MW, on the assumption that a cw beam is required. 1 fig., 1 tab.
A new method for determining the year of birth, the year of death, and hence, the age at death, of post-bomb and recently deceased elephants has been developed. The technique is based on Accelerator Mass Spectrometry radiocarbon analyses of small-sized samples extracted from along the length of a ge-line of an elephant tusk. The measured radiocarbon concentrations in the samples from a tusk can be compared to the {sup 14}C atmospheric bomb-pulse curve to derive the growth years of the initial and final samples from the tusk. Initial data from the application of this method to two tusks will be presented. Potentially, the method may play a significant role in wildlife management practices of African national parks. Additionally, the method may contribute to the underpinnings of efforts to define new international trade regulations, which could, in effect, decrease poaching and the killing of very young animals.
In Randall-Sundrum-type brane-world cosmologies, the dynamical equations on the three-brane differ from the general relativity equations by terms that carry the effects of imbedding and of the free gravitational field in the five-dimensional bulk. Instead of starting from an ansatz for the metric, we derive the covariant nonlinear dynamical equations for the gravitational and matter fields on the brane. The local energy-momentum corrections are significant only at very high energies, and in this regime we show that fluid world-lines have a non-gravitational acceleration off the brane. The imprint on the brane of the nonlocal gravitational field in the bulk is more subtle, and we provide a careful decomposition of this effect. The nonlocal energy density determines the tidal acceleration in the off-brane direction, and can oppose singularity formation via the generalized Raychaudhuri equation. Unlike the nonlocal energy density and flux, the ...
The relativistic time dilation is reviewed in a cosmological context. We show that a clock or twin paradox does not arise if cosmic time is properly taken into account. The receding galaxy background provides a unique frame of reference, and the proper times of geodesic as well as accelerated observers can be linked to the universal cosmic time parameter. This suggests to compare the proper time differentials of the respective observers by determining their state of motion in the galaxy grid. In this way, each observer can figure out whether his proper time is dilated or contracted relative to any other. In particular one can come to unambiguous conclusions on the aging of uniformly moving observers, without reference to asymmetries in measurement procedures or accelerations they may have undergone.
Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion product and degradation of the plastic header.
The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.
Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.
Excessive physical activity plays an important role in the progression of anorexia nervosa (AN) by accelerating weight loss during dietary restriction. To search for mechanisms underlying this trait, a panel of mouse chromosome substitution strains derived from C57BL/6J and A/J strains was exposed to a scheduled feeding paradigm and to voluntary running wheel (RW) access. Here, we showed that A/J chromosomes 4, 12 and 13 contribute to the development of a disrupted RW activity in response to daily restricted feeding. This pattern is characterized by intense RW activity during the habitual rest phase and leads to accelerated body weight loss. Regions on mouse chromosomes 4, 12 and 13 display homology with regions on human chromosomes linked with anxiety and obsessionality in AN cohorts. The...
The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.
A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
Motion Camouflage (MC) is illuminated as a novel strategy in counterattacking anti-satellite by way of stealth trajectory scheduling. The dynamics model of MC in space is developed and a quadratic function with three boundary constraints is employed for trajectory determination. Based on the model a scenario is set to run the simulation. The results indicate given the designed acceleration input, the predator will be moved following a prescribed route, which precisely locates the predator between two objects at each time instant. In the last approaching phase, the motion is achieved with a big bumping rate which guarantees the power of this striking. Methods for deriving minimum fuel cost in the fixed approaching duration and the minimum approaching duration in limited acceleration input are proposed and are verified in the simulation. At last, camouflage is recognized as a multi-faceted affair, in which stealth trajectory design is considered ...
Two different reverse osmosis systems were investigated. The first was a 50-element plant-scale system that is used to treat 2200 m"3 of AECL liquid radwastes annually.It uses thin-film composite (TFC) membranes and operates at an applied pressure of 2760 kPa, with a fixed crossflow of about 40 L/min. The other system uses the same thin-film composite membranes for waste processing but is a two-element pilot-scale system. It is operated at pressures m ranging between 1500 and 7000 kPa, at a fixed crossflow of 55 L/min. The average lifetime of the thin-film composite membranes in the plant-scale processing application at AECL is about 3000 h. After this service life has expired the rejection efficiency declines rapidly from 99.5% to about 95% as the membranes become impaired from chemical cleaning procedures that are required after each 100 m"3 of waste is treated. The permeation flux for the plant-scale system decreases from about 2.2 L/min/element to below 0.5 L/min/element at the end ...
Burnaid is a sorbalene-based cream containing 40 mg/g of tea tree oil and 1 mg/g of triclosan. This investigation was carried out to determine the effect of Burnaid, a commercial tea tree oil preparation, against Enterococcus faecalis (ATCC29212), Staphylococcus aureus (ATCC29213), Escherichia coli (ATCC25922), and Pseudomonas aeruginosa (ATCC27853), with the activity of the base product in the commercial preparation. The organisms were suspended in sterile saline (0.5 McFarland Standard) and inoculated onto horse blood agar (E. faecalis and S. aureus) or Mueller-Hinton agar (E. coli and P. aeruginosa). One hundred microliters of Burnaid unsterilized, Burnaid sterilized and the base product (Tinasolve) were placed in duplicate in wells cut into the agar plates. Sterility and inactivation cultures were also performed on the samples. None of the samples were found to be contaminated with bacteria prior to testing. Only S. aureus and E. coli showed zones of growth inhibition around the ...
In the early 1980s, AECL built a Waste Treatment Centre (WTC) for managing low-level solid and aqueous liquid wastes for converting CANDU wastes. At present, two liquid waste streams are being treated at the WTC. The liquid waste streams are volume-reduced by a combination of continuous crossflow microfiltration (MF), spiral wound reverse osmosis (SWRO) and tubular reverse osmosis (TRO) membrane technologies. The concentrate produced from the TRO system and the volume-reduced MF backwash solutions are evaporated while simultaneously adding bitumen in a thin-film evaporator. A water-free product of chemical and radiochemical salts and bitumen is removed in 200-L galvanized steel drums for storage. The radiation field of product drums on contact typically has a value of 0.5 to 3 R/h depending upon the feed concentration of radioactivity to the evaporator. The total solids content in the 200-L drum ranges from 25 to 35%. Encapsulated in the bitumen matrix are a ...
This patent describes a preflush fluid for preventing lost circulation during the cementing of a well, the fluid consisting essentially of: (a) water; (b) about 10 to about 30 percent by weight of water (% BWOW) cement; (c) about 5 to about 30% BWOW calcium sulfate selected from the group consisting of calcium sulfate hemihydrate, calcium sulfate dihydrate, and mixtures thereof; and (d) an alkali metal-containing quick-hardening accelerator.
Very often in many textbooks the formalism of the general theory of relativity is applied to gravitational problems. We think that it would be didactically useful to show how it can be adopted also for describing physical situations in accelerated frames of reference by working out in detail a particular case. This choice will also offer an opportunity to discuss a classical topic of relativistic physics. Indeed, we deal analytically with a version of the so-called clock paradox in which the moving clock performs a circular motion. The rest clock is denoted as (1), the rotating clock is (2), the inertial frame in which (1) is at rest and (2) moves is I and, finally, the accelerated frame in which (2) is at rest and (1) rotates is A. By using the general theory of relativity in order to describe the motion of (1) as seen in A we will show the following features. (I) A differential ageing between (1) and (2) occurs at their reunion and it has an ...
A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.
The CLIC (Compact Linear Collider) high-gradient RF structure testing program has been carried out in order to gain insight into the physical processes involved in RF breakdown, determine the mechanisms that limit gradient and produce damage so that technical concepts can be developed which allow higher accelerating gradients. Two main paths towards higher gradients have emerged from this program, and the performances of two new structures which incorporate them are presented.