WorldWideScience
1

Accelerated hyperfractionation (AHF) compared to conventional fractionation (CF) in the postoperative radiotherapy of locally advanced head and neck cancer: influence of proliferation  

UK PubMed Central (United Kingdom)

Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available

2002-02-12

2

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

3

Evaluation on the clinical effect of lysozyme chloride in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Lysozyme chloride was administered to 84 patients of laryngeal cancer and the clinical effect was discussed. Lysozyme chloride delayed the appearance of swelling and white plaque while it accelerated that of inflammatory erythema in radiotherapy. No difference of the local inflammation was found between lysozyme administered groups and not administered groups when irradiation and chemotherapy were combined. Any side effect was not seen in blood picture of all cases by using lysozyme chloride.

1982-10-01

4

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

5

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

6

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion ...

1995-03-01

7

Monte Carlo treatment planning for photon and electron beams  

British Library Electronic Table of Contents (United Kingdom)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...

2007-01-01

8

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement ...

10

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

11

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

12

Development of power supplies for compact medical synchrotron  

International Nuclear Information System (INIS)

A compact medical synchrotron is being developed which aims to promote the advanced radiotherapy based on the accelerator. As it is small-sized, a high field dipole magnet of 3 T at 200 kA is used. It is excited by the discharge current of the capacitor bank of which waveform is half sinusoidal. To provide with the flat field of 10 - 20 #mu#s duration for the multi-turn injection an additional power supply is developed. For the quadrupole magnet a 100 kHz switch-mode power supply is adopted as it requires the fine tuning and accurate field tracking to the dipole field. (author)

2005-06-01

13

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target ...

1995-10-01

14

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have ...

2007-04-01

15

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a ...

2007-10-29

16

Neoadjuvant vs adjuvant pelvic radiotherapy for locally advanced rectal cancer: Which is superior?  

UK PubMed Central (United Kingdom)

The treatment of locally advanced rectal cancer including timing and dosage of radiotherapy, degree of sphincter preservation with neoadjuvant radiotherapy, and short and long term effects of radiotherapy...Full Text Available

2011-02-21

17

Radiation-induced large intracranial vessel occlusive vasculopathy.  

Science.gov (United States)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

18

Radiation-induced large intracranial vessel occlusive vasculopathy  

Energy Technology Data Exchange (ETDEWEB)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

19

A retrospective comparison of endoscopic stenting alone with stenting and radiotherapy in non-resectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Radiotherapy has been reported to be of benefit in prolonging the survival of patients with cholangiocarcinoma. This study examined whether radiotherapy in addition to endoscopic stenting improved survival. The survival advantage of radiotherapy in those with a type II/III stricture is seen only in the first 10 months after diagnosis. The costs of radiotherapy and significantly increased time spent in hospital, however, raise doubts over its routine use in the management of non-resectable cholangiocarcinoma. (Author).

20

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

21

Protons, heavy ions, radioactive beams: new ways for radiotherapy. Protons, ions lourds, faisceaux radioactifs: de nouvelles voies pour la radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the principles, applications and advantages of proton and heavy ion beams used for radiotherapy.

1993-07-01

22

Fractionated stereotactic radiotherapy in the treatment of pituitary macroadenomas  

UK PubMed Central (United Kingdom)

BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available

2008-12-01

23

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

24

Adaptive Radiation for Lung Cancer  

UK PubMed Central (United Kingdom)

The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such...Full Text Available

2011-01-01

25

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...

2003-08-17

26

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV shrinkage was 15.1%/40.7% ...

2009-09-01

27

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any ...

2009-02-01

28

Quality controls in radiotherapy. From experiences of the first course-debate  

International Nuclear Information System (INIS)

The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure.

1998-12-03

32

Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system  

UK PubMed Central (United Kingdom)

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available

2009-01-01

35

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax phantom. It was found that the ...

2001-04-01

36

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize radiobiological damages ...

2010-07-01

37

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize radiobiological damages ...

2010-08-18

38

Ewing's sarcoma family tumors of the humerus: Outcome of patients treated with radiotherapy, surgery or surgery and adjuvant radiotherapy  

International Nuclear Information System (INIS)

Background and purpose: Local treatment for non-metastatic Ewing's sarcoma family tumors (ESFTs) is controversial. Results achieved in a single institution in patients with ESFT of the humerus are presented. Materials and methods: Patients treated between 1983 and 2000 for ESFT of the humerus were included. The impact of local treatment (surgery, radiotherapy or both) on outcome was assessed. Results: 55 patients: 34 males (62%); 21 females (38%); mean age: 17.9 (range: 3-40). Local treatment: surgery in 27 patients (49%), radiotherapy in 17 (31%) and surgery followed by radiotherapy in 11 (20%). After a mean follow-up of 15 years (range: 7-25 years), 27 patients (49%) remained continuously disease free, 27 (49%) relapsed and one died of chemotherapy toxicity. The local recurrence rate was 13% overall: 18% (3/17) after radiotherapy, 7% (2/27) after surgery and 19% (2/11) after surgery followed by ...

2009-11-01

39

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of ...

2000-04-01

40

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning  

CERN Document Server

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning

1998-01-01

44

Radiotherapy in the management of Kaposi's sarcoma: comparison of 8 Gy versus 6 Gy.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate prospectively the efficacy of a single fraction of high-dose radiotherapy in patients with Kaposi's sarcoma. PATIENTS: Between 1994 and 2004, 47 patients with Kaposi's sarcoma...Full Text Available

2006-07-01

45

Radiation Therapy and Psychological Distress in Gynecologic Oncology Patients: Outcomes and Recommendations for Enhancing Adjustment  

UK PubMed Central (United Kingdom)

SummaryRadiotherapy is used commonly in the treatment of gynecologic malignancies. Many patients experience emotional distress prior to the initiation of radiotherapy, during...Full Text Available

1986-01-01

46

Objective assessment of deformable image registration in radiotherapy: A multi-institution study  

UK PubMed Central (United Kingdom)

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area...Full Text Available

2008-12-01

47

Intensity modulated radiotherapy: advantages, limitations and future developments  

UK PubMed Central (United Kingdom)

Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available

48

Early and late skin reactions to radiotherapy for breast cancer and their correlation with radiation-induced DNA damage in lymphocytes  

UK PubMed Central (United Kingdom)

IntroductionRadiotherapy outcomes might be further improved by a greater understanding of the individual variations in normal tissue reactions that determine tolerance. Most published...Full Text Available

2005-01-01

49

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

50

A Hybrid Strategy of Offline Adaptive Planning and Online Image Guidance for Prostate Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

The offline adaptive radiotherapy (ART) has been used to effectively correct and compensate the prostate motion and reduce the required margin. The efficacy depends on the characteristics of...Full Text Available

2010-04-21

51

Multidisciplinary management of Ewing's sarcoma : a pragmatic approach  

International Nuclear Information System (INIS)

Treatment of Ewing's sarcoma by radiotherapy, chemotherapy and surgery singly and in combination is reviewed.(M.G.B.).

52

First Result of Induction Acceleration in the KEK Proton Synchrotron  

CERN Document Server

First Result of Induction Acceleration in the KEK Proton Synchrotron

2005-01-01

53

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

54

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...

55

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ionization chamber. The absorbed dose by ...

2004-12-01

56

Production by surface sputtering and acceleration of heavy negative ions in tandem accelerators  

Energy Technology Data Exchange (ETDEWEB)

The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.

1992-10-05

57

Silund Nanosecond High-Current Linear Induction Accelerator ...  

Science.gov (United States)

... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...

1972-07-13

58

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...

2009-06-15

59

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

60

Biopsy examination during the course of radiotherapy. Progress report. [DNA content of tumor cells in biopsy samples determined by microfluorometric or multiangle light-scatter spectrometry  

Science.gov (United States)

Studies begun during the first year of this project on biopsies from spontaneous tumors in dogs and from human patients undergoing radiotherapy treatment were continued. The results indicate that significant fractions of the spontaneous tumors in dogs and cervical carcinomas in patients undergoing radiotherapy have a DNA content higher than normal diploid cells. The higher DNA content in tumor cells permits distinguishing them from normal cells in the biopsy material with the aid of flow microfluorometric (FMF) instrumentation or multiangle light-scatter spectrometry.

1977-12-01

61

Similar Treatment Outcomes for Radical Cystectomy and Radical Radiotherapy in Invasive Bladder Cancer Treated at a United Kingdom Specialist Treatment Center  

International Nuclear Information System (INIS)

Purpose: To conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer. Patients and Methods: Between March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data. Results: There was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences in the radiotherapy group (24 solitary), but there was no significant difference in distant recurrence-free ...

2008-02-01

62

Similar Treatment Outcomes for Radical Cystectomy and Radical Radiotherapy in Invasive Bladder Cancer Treated at a United Kingdom Specialist Treatment Center  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer.Patients and MethodsBetween March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data.ResultsThere was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences...

2008-01-01

63

Radiotherapy for nonfunctioning pituitary adenomas: from conventional to modern stereotactic radiation techniques  

British Library Electronic Table of Contents (United Kingdom)

The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...

2007-01-01

64

Orbital lymphoma: Role of radiation  

UK PubMed Central (United Kingdom)

The purpose of this article is to review the literature for clinical presentation, treatment, outcome and complications of using radiotherapy for the treatment of orbital lymphoma. For this, MEDLINE,...Full Text Available

2009-03-01

65

Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

2005-01-01

66

Green Tea Extract (Epigallocatechin-3-Gallate) Reduces Efficacy of Radiotherapy on Prostate Cancer Cells  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...

2011-01-01

67

Constitution of a centralised data base for the internal quality control in radiotherapy; Constitution d'une base de donnees centralisee pour le controle de qualite interne en radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)

2009-10-15

68

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

69

Adaptive Management of Liver Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available

2010-04-01

72

Studies of accelerated compact toruses  

Energy Technology Data Exchange (ETDEWEB)

In an earlier publication we considered acceleration of plasma rings (Compact Torus). Several possible accelerator configurations were suggested and the possibility of focusing the accelerated rings was discussed. In this paper we consider one scheme, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focusing) during acceleration. Because the allowable acceleration force, F/sub a/ = kappaU/sub m//R where (kappa < 1), increases as R/sup -2/, the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case, however, since the accelerating flux can expand as the ring ...

1983-01-04

73

The value of radiotherapy in the treatment of Ewing's sarcoma in children  

International Nuclear Information System (INIS)

Results of treatment of 30 children with Ewing's sarcoma irradiated in the First Radiotherapy Department, Cancer Center, Warsaw, in the period 1983-1992, are described. In 40% of patients NED survival from 1 till 10 years and in 70% the local control was obtained, and no serious radiations equelae were observed. (author).

74

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

75

Radiotherapy quality assurance review in a multi-center randomized trial of limited-disease small cell lung cancer: the Japan Clinical Oncology Group (JCOG) trial 0202  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of this study was to analyze the radiotherapy (RT) quality assurance (QA) assessment in Japan Clinical Oncology Group (JCOG) 0202, which was the first trial...Full Text Available

76

INL Advanced Radiotherapy Research Program Annual Report 2004  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.

2005-06-01

77

INEEL Advanced Radiotherapy Research Program Annual Report for 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-01

78

INEEL Advanced Radiotherapy Research Program Annual Report 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-23

79

Endocavitary radiotherapy of rectal tumours; Endokavitaer straalebehandling ved distale rectum tumorers  

Energy Technology Data Exchange (ETDEWEB)

The authors describe their experience of endocavitary radiotherapy of adenomas and carcinomas of the lower rectum. The method is an alternative for patients who cannot undergo standard surgical procedure or do no want a permanent colostomy. This method is cheap, fast and causes little discomfort to the patients, gives reasonable long-term results and has low morbidity. 11 refs., 4 figs., 2 tabs.

1997-02-01

80

Physical aspects of quality assurance in radiotherapy: A protocol for quality control  

International Nuclear Information System (INIS)

In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a ...

2009-06-21

81

Ewing's sarcoma: a combined approach in the management  

International Nuclear Information System (INIS)

Twenty-seven histologically confirmed cases of localised Ewing's sarcoma were treated by two different regimes. Radiotherapy alone was used in 13 cases and a combination of chemotherapy and radiotherapy in 14. Single agent chemotherapy (cyclophosphamide) was given sequentially in nine patients and cyclophosphamide and actinomycin-D in five. There is a significant difference in the response to these different regimes. Only 69.2% of patients treated by radiotherapy alone were disease-free, for a median period of 10.4 months and metastases were noticed in 53.8% of cases. The disease-free survival in patients treated by combination therapy (radiotherapy and chemotherapy) was 18.4 months and metastases were seen in only 42.9%. However, no metastases were seen in patients who received cyclophosphamide and actinomycin-D, during a period of 14 months and only one patient showed residual disease. It is concluded ...

82

Radiotherapy versus surgery in good-risk Ewing's sarcoma. An analysis of the CESS 86-data  

International Nuclear Information System (INIS)

The evaluation of radiotherapy and surgery as exclusive local treatment in comparably selected subgroups of patients with Ewing's sarcoma on the basis of the CESS 86-data. In the German multicenter Ewing's sarcoma study CESS 86, treatment consisted for four 9-week-courses of VACA- or VAIA-chemotherapy plus local therapy. VACA (vincristine, actinomycin D, cyclophosphamide, adriamycin) was given in low-risk extremity tumors with a tumor volume below 100 cm"3. Highrisk patients with central lesions or a tumor volume >100 m"3 received VAIA (ifosfamide instead of cyclophosphamide). Local therapy started after one complete chemotherapy course in week 10. Based on an individual decision in each patient, local therapy was either radical surgery or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy. Because of poor results with radiotherapy in a preceeding study, it was intended to restrict ...

83

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France; Ameliorer la qualite et la securite de la radiotherapie: un objectif conjoint de l'A.S.N. et de l'Agence regionale de l'hospitalisation Ile de France. Reflexions sur une cooperation feconde en Ile de France  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...

2009-02-15

84

Radiation therapy in Ewing's sarcoma: an update of the CESS 86 trial  

International Nuclear Information System (INIS)

Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and ...

1995-07-15

85

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...

2009-01-01

86

Optimization of shielding for a 60 MeV alpha particle accelerator  

International Nuclear Information System (INIS)

Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.

1988-04-18

87

A General Model of the Resistive Wall Instability in Linear Accelerators  

Energy Technology Data Exchange (ETDEWEB)

A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.

2007-01-08

88

IFA-2 collective ion accelerator experiments  

Energy Technology Data Exchange (ETDEWEB)

Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.

1985-10-01

89

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system  

CERN Document Server

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system

2010-01-01

90

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project  

CERN Document Server

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project

1961-01-01

91

Accelerator technology program, January-June 1982. Status report  

International Nuclear Information System (INIS)

The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.

94

Scalp Angiosarcoma Remission with Bevacizumab and Radiotherapy without Surgery: A Case Report and Review of the Literature  

UK PubMed Central (United Kingdom)

Angiosarcoma (AS) is a rare and aggressive vascular neoplasm with very poor prognosis. Patients with extensive cutaneous AS who are not surgical candidates have very limited options since there is no...Full Text Available

2011-01-01

95

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

96

Range and modulation dependencies for proton beam dose per monitor unit calculations  

UK PubMed Central (United Kingdom)

Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available

2009-02-01

97

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

98

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

99

Quality controls in radiotherapy. From experiences of the first course-debate; Controlli di qualita' in radioterapia. Dalle esperienze del primo corso-dibattito  

Energy Technology Data Exchange (ETDEWEB)

The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure. [Italian] Questo documento e' dedicato al primo corso-dibattito sui controlli di qualita' in radioterapia svoltosi a Roma il 3-4 dicembre 1998 e il 3-5 maggio 1999 in collaborazione tra l'Istituto Superiore di Sanita' e l'Istituto Regina Elena. Esso presenta gli argomenti ritenuti critici per l'assicurazione di qualita' in radioterapia in relazione all'intera procedura radioterapica, in base alle esperienze dei partecipanti.

2000-07-01

100

Prevention and treatment of functional and structural radiation injury in the rat heart by pentoxifylline and alpha-tocopherol  

UK PubMed Central (United Kingdom)

PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available

2008-09-01

101

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

102

PLESIOTHERAPY FOR NON-MELANOMA SKIN CANCER: INNOVATING TO OVERCOME!  

UK PubMed Central (United Kingdom)

Background:The non-surgical management of non-melanoma skin cancers is an area requiring clinical investigation. Radiotherapy has a role in treatment for a defined subset...Full Text Available

2010-10-01

103

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

104

Metastatic tumor of thoracic and lumbar spine: prospective study comparing the surgery and radiotherapy vs external immobilization with radiotherapy; Metastases do segmento toracico e lombar da coluna vertebral: estudo prospectivo comparativo entre o tratamento cirurgico e radioterapico com a imobilizacao externa e radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Bone metastases at the thoracic and lumbar segment of the spine are usually presented with painful sensation and medullar compression. The treatment is based on the clinical and neurological conditions of the patient and the degree of tumor invasion. In the present study, 32 patients with spinal metastasis of thoracic and lumbar segment were prospectively analyzed. These patients were treated by decompression and internal stabilization followed by radiotherapy or irradiation with external immobilization. The election of the groups was in accordance with the tumor radiotherapy sensitivity, clinical conditions, spinal stability, medullar or nerve compression and patient's decision. The Frankel scale and pain visual test were applied at the moment of diagnosis and after 1 and 6 months. The surgical group had better results with preserving the ambulation longer and significant reduction of pain.(author)

2007-09-15

105

Estimation of cancer risks from radiotherapy of benign diseases  

Energy Technology Data Exchange (ETDEWEB)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-15

106

Estimation of cancer risks from radiotherapy of benign diseases  

International Nuclear Information System (INIS)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-01

107

Development of a Novel Post-processing Treatment Planning Platform for 4D Radiotherapy  

UK PubMed Central (United Kingdom)

The aim of this study is to develop an Automatic Post-processing Tool for four-dimensional (4D) treatment planning (APT4D) that enables the user to perform some necessary procedures related...Full Text Available

2008-04-01

108

Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available

109

Combined chemotherapy and radiotherapy of localized and metastasizing Ewing's sarcoma  

International Nuclear Information System (INIS)

Between 1973 and 1978 combined radiotherapy and chemotherapy were given to 22 patients with histologically proven Ewing's sarcoma. The combined chemotherapy consisted of cyclophosphamide, vincristin, adriamycin, as well as dacarbazine in some cases. The neoplasm was a localized one at the beginning of treatment in 14 of the 22. These patients received high-voltage rediotherapy to the primary focus at a focal dose between 42 and 55 Gray (4200-5500 rad), followed by chemotherapy. After 6-8 treatment cycles, adriamycin was replaced by methotrexate. Nine of the 14 patients survived without recurrence for 12 to over 59 months. Eight patients had extensive metastases at the beginning of treatment: they at first received only chemotherapy, followed by radiotherapy or operation, as indicated. Full clinical remission was achieved in five of them: in three this remission has now lasted for more than 18, 40 and 44 months, respectively. These results ...

110

Challenge and Hope in Radiotherapy of Hepatocellular Carcinoma  

UK PubMed Central (United Kingdom)

Hepatocellular carcinoma (HCC) is one of the most critical global health issues. With frequent association of viral liver disease, HCC is highly complex, harboring both cancer and chronic liver disease....Full Text Available

2009-10-31

111

An optimization method for reference dose point of rectum in brachytherapy of gynecological neoplasms  

International Nuclear Information System (INIS)

Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose ...

2002-05-01

112

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting ...

2001-09-01

113

A viral vaccine encoding PSA induces antigen spreading to a common set of self proteins in prostate cancer patients  

UK PubMed Central (United Kingdom)

PurposeWe previously reported a randomized phase II clinical trial combining a poxvirus-based vaccine encoding PSA with radiotherapy in patients with localized prostate...Full Text Available

2010-08-01

114

A systematic review to investigate the effectiveness and acceptability of interventions for moist desquamation in radiotherapy patients  

Energy Technology Data Exchange (ETDEWEB)

Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice ...

2009-08-15

115

Therapy of children with Ewing's sarcoma  

International Nuclear Information System (INIS)

Combined treatment of 131 patients aged 3-16 with local form of Ewing's sarcoma is carried out. Survival rate per year was studied in patients without diagnosed metastases depending on chemiotherapy method. It is stated that improved results of treatment of children with Ewing's sarcoma may be achieved by combining radiotherapy with long-term systemic polychemotherapy. The most efficient and expedient method of radiotherapy of long bone sarcoma in children is dialy three-field irradiation with 2 Gy at SFD to the tumor 60 Gy, and adjacent tissues - 40 Gy.

116

A dose computation algorithm used in MLC conformal treatment  

International Nuclear Information System (INIS)

A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)

2007-12-01

117

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France  

International Nuclear Information System (INIS)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...

2009-02-01

118

Implementation of an algorithm for absorbed dose calculation in high energy photon beams at off axis points  

International Nuclear Information System (INIS)

Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...

2008-10-19

120

Status of LBL/LLNL FEL (free electron laser) research for two beam accelerator applications  

Energy Technology Data Exchange (ETDEWEB)

We review the status of free electron laser (FEL) research being conducted at LBL and LLNL as part of a broader program of research on two beam accelerators (TBAs). Induction accelerator-driven FELs for use as power sources for high-gradient accelerators are discussed, along with preliminary cost estimates for this type of power source. Finally, a promising new version of an FEL/TBA is described. 25 refs., 1 fig., 3 tabs.

1989-03-01

121

ISR site  

CERN Document Server

A last look at the green field, in the triangular wedge of land stray radiation near the CERN accelerators.

1965-01-01

122

IEE, accelerated waste mgt, McM  

Science.gov (United States)

... in ATCM Recommendation XIV-2. The USAP's materials and waste management efforts are consistent with ...

124

Foreign Affair's: Fool's Gold  

Wastenet

aged gracefully: premature and accelerated corro - sion, erosion, and stress are raising maintenance costs.Last

126

Biophotonics and Bone Biology  

Science.gov (United States)

One of the more-serious side effects of extended space flight is an accelerated bone loss

2004-01-01

127

A multidisciplinary study investigating radiotherapy in Ewing's sarcoma: end results of POG no. 8346  

International Nuclear Information System (INIS)

Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone radiation to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy, and the ...

1998-08-01

128

PIC Simulations Of Ion Acceleration By Linearly And Circularly Polarized Laser Pulses  

Science.gov (United States)

Linearly polarized laser radiation accelerates electrons to very high velocities and these electron form a sheath layer on the rear side of thin targets where preferentially protons are accelerated. When mass-limited targets are used, the lateral transport of the absorbed laser energy is reduced and the accelerating field is enhanced. For targets consisting of two ion species, heavier ions facilitate formation of quasi-monoenergetic bunch of lighter ions. For circularly polarized light, fast electron production is suppressed by the absence of the oscillatory component of the ponderomotive force. Ions are accelerated on the front side by the separation field and very thin foil can be accelerated as one massive quasi-neutral block. As all ion species acquire the same velocity, this acceleration mechanism is preferred for heavier ions.

2008-06-24

129

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

130

Collective ion acceleration in systems with a virtual cathode  

International Nuclear Information System (INIS)

The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)

2002-11-30

131

Brazing techniques for side-coupled electron accelerator structures  

Energy Technology Data Exchange (ETDEWEB)

The collaboration between the Los Alamos National Laboratory and the National Bureau of Standards (NBS), started in 1979, has led to the development of an advanced c-w microtron accelerator design. The four 2380-MHz NBS accelerating structures, containing a total of 184 accelerating cavities, have been fabricated and delivered. New fabrication methods, coupled with refinements of hydrogen-furnace brazing techniques described in this paper, allow efficient production of side-coupled structures. Success with the NBS RTM led to Los Alamos efforts on similar 2450-MHz accelerators for the microtron accelerator operated by the Nuclear Physics Department of the University of Illinois. Two accelerators (each with 17 cavities) have been fabricated; in 1986, a 45-cavity accelerator is being fabricated by private industry with some assistance from Los ...

1986-01-01

132

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation doses (1-100 mGy) ...

2007-09-15

133

The role of surgical margins in treatment of Ewing's sarcoma family tumors: Experience of a single institution with 512 patients treated with adjuvant and neoadjuvant chemotherapy  

International Nuclear Information System (INIS)

Purpose: To evaluate the importance of surgical margins for local and systemic control of Ewing's sarcoma family tumors (ESFT). Methods and Materials: Between 1979 and 1999, 512 patients with ESFTs entered 4 different adjuvant and neoadjuvant studies performed at a single institution. Of these patients, 335 were treated with surgery alone (196) or surgery followed by radiotherapy at doses of 44.8 Gy (139). We compared their outcome with that of the 177 patients who were locally treated by radiotherapy at 60 Gy. Results: Local control (88.8% vs. 80.2%, p < 0.009) and 5-year disease-free survival (63.8% vs. 47.6%, p < 0.0007) were significantly better in patients treated with surgery and, among them, in those with adequate surgical margins (96.6% vs. 71,7%, p < 0.0008, and 69.6% vs. 46.3%, p < 0.0002). Nonetheless, better results were observed only in extremity tumors. Conclusions: Surgery is better than ...

2006-07-01

134

The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months ...

2009-12-01

135

Renal artery stenosis after radiotherapy for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been ...

2008-09-01

136

Radiotherapy in Ewing's sarcoma and PNET of the chest wall: results of the trials CESS 81, CESS 86 and EICESS 92  

International Nuclear Information System (INIS)

Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...

1998-12-01

137

A randomised controlled trial of intervention site radiotherapy in malignant pleural mesothelioma  

International Nuclear Information System (INIS)

Background and purpose: To assess the effectiveness of radiotherapy in preventing tumour seeding after chest drain or pleural biopsy in patients with malignant mesothelioma and to determine, if tract metastases appear, whether they are tender or troublesome to patients. Patients and methods: Patients with a histological diagnosis of pleural mesothelioma and an invasive procedure within the preceding 21 days were stratified by age, performance status and treatment centre. Randomisation was performed between immediate drain site radiotherapy 21 Gy in three fractions (XRT arm) or best supportive care (BSC) with follow-up to 12 months. Patients were asked to complete questionnaires on treatment toxicity and on symptoms from any tract metastases detected. Results: Sixty-one patients were recruited from two centres between 1998 and 2004; 56 men, 5 women, median age 70. 31 were allocated to drain site radiotherapy. Seven patients ...

2007-07-01

138

Electron accelerators, present and future applications  

International Nuclear Information System (INIS)

The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, electron beams, plasma, ...

139

Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)  

Energy Technology Data Exchange (ETDEWEB)

The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...

1988-04-01

140

Woven polydioxanone biodegradable stents: a new treatment option for benign and malignant oesophageal strictures  

International Nuclear Information System (INIS)

We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. The BD stents need to be loaded into a conventional pull-back delivery system but are then placed in a standard fashion. Pre-dilatation should be avoided to reduce the risk of migration, however if migration occurs the stents can be left to dissolve in the stomach. The stents are radiolucent but easily identified on CT with minimal artefact and thus might even aid with radiotherapy planning. BD stents offer an exciting new strategy for therapy-resistant benign strictures as well as a supportive measure for oesophageal cancer undergoing non-surgical treatment. (orig.)

2010-05-01

141

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

142

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

143

Local control of Ewing's sarcoma: an analysis of 67 patients  

International Nuclear Information System (INIS)

Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).

144

Fitness of equipment used for medical exposure to ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which ...

1992-05-01

145

Eosinophilia after radiotherapy for non-resected cervical cancer  

International Nuclear Information System (INIS)

The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).

1982-01-01

146

U of C site vies for new particle accelerator  

CERN Multimedia

"American dominance in the study and development of high-energy particle physics may be seriously compromised, according to a report issued by the National Academy of Sciences, unless efforts are made to ensure that the next high-energy particle accelerator - the International Linear Collider (ILC) - will be constructed in the U.S.

2006-01-01

147

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy  

UK PubMed Central (United Kingdom)

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy...Full Text Available

2009-02-01

148

Knockout of Arabidopsis ACCELERATED-CELL-DEATH11 encoding a sphingosine transfer protein causes activation of programmed cell death and defense  

UK PubMed Central (United Kingdom)

We describe the lethal, recessive accelerated-cell-death11 Arabidopsis mutant (acd11). Cell death in acd11 exhibits characteristics of animal apoptosis...Full Text Available

2002-02-15

149

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion power plants are now projected to be cost-competitive with other conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost ...

1988-02-01

150

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

International Nuclear Information System (INIS)

A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion power plants conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are presented and discussed, ...

151

Development of an Accelerated Weathering Protocol using Weatherometers for Reliability Study of Mini-Modules and Encapsulation Materials  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the needs, reasoning, approaches, and technical details to establish a practical accelerated weathering test (AWT) protocol for indoor testing of the photothermal stability of encapsulation materials and encapsulated solar cells and minimodules.

2000-01-01

152

Beam-forming system for electrostatic accelerator  

International Nuclear Information System (INIS)

A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.

1988-01-01

153

Analytical validation of accelerator mass spectrometry for pharmaceutical development  

UK PubMed Central (United Kingdom)

The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available

2010-03-01

154

Accelerator technology program, January-June 1982. Status report  

Science.gov (United States)

The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.

1983-12-01

155

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

156

Accelerated surgical stay programs. A mechanism to reduce health care costs.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To increase cost-efficiency while maintaining the standard of medical care, an accelerated surgical stay program for patients having breast surgery was instituted. SUMMARY BACKGROUND DATA:...Full Text Available

1994-04-01

157

The joint project for high-intensity proton accelerators  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) are promoting the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint project prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. It was originally written in English and translated into Japanese with some corrections. (author)

2000-02-01

158

Operational status of the Brookhaven National Laboratory Accelerator Test Facility  

International Nuclear Information System (INIS)

Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.

1990-06-11

160

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

161

Heavy-ion accelerators and predicted lifetimes of highly stripped ions  

International Nuclear Information System (INIS)

(Sep 1973). United Kingdom Sinanoglu, O. Luken, W. Yale Univ., New Haven,

1973-01-01

163

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

164

Beam stability study based on the beam trajectory jitter in the KEKB injector linac  

International Nuclear Information System (INIS)

... Tsukuba, Ibaraki (Japan) 389 p. PARTICLE ACCELERATORS beam monitoring

2001-08-01

165

Accelerated aging tests for radiation degradation of organic materials  

International Nuclear Information System (INIS)

(Jun 1984). United States Clough, RL Gillen, KT Sandia Nat'l Laboratories

1984-06-03

166
167

Explosive acceleration of liquid from a cylindrical container using the implosive technique  

British Library Electronic Table of Contents (United Kingdom)

Tthe acceleration of a liquid from a cylindrical container by the products of instantaneous detonation of a superimposed explosive charge (implosion method) is studies numerically in a two-dimensional formulation. Analytical formulas for the asymptotic velocities of liquid expansion and acceleration of the container body were obtained using numerical calculations in a one-dimensional approximation. The effect of the fracture of the body on the velocity of liquid expansion was studied in a two-dimensional formulation.

2011-01-01

168

Enabling Technologies for Petascale Electromagnetic Accelerator Simulation  

Energy Technology Data Exchange (ETDEWEB)

The SciDAC2 accelerator project at SLAC aims to simulate an entire three-cryomodule radio frequency (RF) unit of the International Linear Collider (ILC) main Linac. Petascale computing resources supported by advances in Applied Mathematics (AM) and Computer Science (CS) and INCITE Program are essential to enable such very large-scale electromagnetic accelerator simulations required by the ILC Global Design Effort. This poster presents the recent advances and achievements in the areas of CS/AM through collaborations.

2007-11-09

169

Design and fabrication of a traveling-wave muffin-tin accelerating structure at 90 GHz  

Energy Technology Data Exchange (ETDEWEB)

A prototype of a muffin-tin accelerating structure operating at 32 times the SLAC frequency (2.856 GHz) was built for research in high gradient acceleration. A traveling-wave design with single input and output feeds was chosen for the prototype which was fabricated by wire electrodischarge machining. Features of the mechanical design for the prototype are described. Design improvements are presented including considerations of cooling and vacuum.

1997-05-01

170

Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report  

International Nuclear Information System (INIS)

The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.

171

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

172

Use of absorbable mesh to displace bowel and avoid radiation enteropathy, during therapy of pelvic Ewing's sarcoma  

International Nuclear Information System (INIS)

The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).

173

Synergistic activity of the proteasome inhibitor PS-341 with non-myeloablative 153-Sm-EDTMP skeletally targeted radiotherapy in an orthotopic model of multiple myeloma  

UK PubMed Central (United Kingdom)

Multiple myeloma is a highly radiosensitive skeletal malignancy, but bone-seeking radionuclides have not yet found their place in disease management. We previously reported that the proteasome inhibitor...Full Text Available

2006-05-15

174

Radiotherapy and multimodality management of cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in multivariate analysis ...

1999-04-01

175

Quality assurance in radiotherapy: Proposal of guidelines concerning clinical and technological aspects; Assicurazione di qualita` in radioterapia: Proposta di linee guida in relazione agli aspetti clinici e tecnologici  

Energy Technology Data Exchange (ETDEWEB)

The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.

1996-12-01

176

NADPH oxidase-mediated reactive oxygen species production activates hypoxia-inducible factor-1 (HIF-1) via the ERK pathway after hyperthermia treatment  

UK PubMed Central (United Kingdom)

Hyperthermia (HT) is a strong adjuvant treatment with radiotherapy and chemotherapy because it causes tumor reoxygenation. However, the detailed molecular mechanisms of how HT enhances tumor oxygenation...Full Text Available

2010-11-23

177

Localization of 131I-labeled p97-specific Fab fragments in human melanoma as a basis for radiotherapy.  

UK PubMed Central (United Kingdom)

33 patients with advanced malignant melanoma were studied after intravenous administration of 131I-labeled Fab fragments specific for p97, an oncofetal glycoprotein of human melanoma. In all, 47 gamma...Full Text Available

1983-12-01

178

Irradiation with and without razoxane in the treatment of incompletely resected or inoperable recurrent rectal cancer. Results of a small randomized multicenter study  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, and toxicity. Results: The combined ...

2007-07-15

179

Ewing's sarcoma in childhood and adolescence  

International Nuclear Information System (INIS)

A review of main issues in diagnosing, complex treatment and prognosis of Ewing's sarcoma is presented. Current trend in chemotherapy, radiotherapy and surgery of the disease is discussed. Unfavourable prognosis is attributed to the systematic character of the disease, necessitating a complex therapeutic approach. Attempts to make an optimal combination of the three therapeutic methods in order to improve survival and reduce the rate of post-treatment complications are analyzed. 37 refs., 4 tabs. (author).

180

Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric...Full Text Available

2008-01-01

181

Dose specification and quality assurance of RTOG protocol 95-17; a cooperative group study of 192Ir breast implants as sole therapy  

UK PubMed Central (United Kingdom)

PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available

2007-12-01

182

Bullous pemphigoid after radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.

1988-02-01

183

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

184

Dynamical Cycles in Charge and Energy for Iron Ions Accelerated in a Hot Plasma  

Science.gov (United States)

We consider a unified model of Fe ion acceleration in the solar corona. The model comprises charge-changing processes, Coulomb energy losses, and both regular and stochastic acceleration. At a given acceleration scenario, the type of acceleration is found to have a minor effect on the mean charge states, but the shapes of the charge-state distributions produced by regular acceleration and by stochastic acceleration are different. During a continual acceleration at coronal temperatures, iron ions typically follow rising trajectories on the charge-energy plane. These trajectories are situated below the mean equilibrium charge curve defined from the balance of ionization and recombination at fixed energy. During stopping, the iron ions cross the equilibrium charge curve and run through a series of charge states above the mean equilibrium charge ...

2001-08-01

185

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new ...

2009-06-17

186

Proposal of procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions; Proposta de procedimentos para evitar erros em radioterapia baseados em licoes aprendidas de exposicoes acidentais  

Energy Technology Data Exchange (ETDEWEB)

In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...

2007-07-01

187

Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategies  

Energy Technology Data Exchange (ETDEWEB)

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...

2008-03-21

188

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

Energy Technology Data Exchange (ETDEWEB)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from ...

1992-10-01

189

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from ...

1992-01-01

190

Future Accelerators, Muon Colliders, and Neutrino Factories  

Energy Technology Data Exchange (ETDEWEB)

Particle physics is driven by five great topics. Neutrino oscillations and masses are now at the fore. The standard model with extensions to supersymmetry and a Higgs to generate mass explains much of the field. The origins of CP violation are not understood. The possibility of extra dimensions has raised tantalizing new questions. A fifth topic lurking in the background is the possibility of something totally different. Many of the questions raised by these topics require powerful new accelerators. It is not an overstatement to say that for some of the issues, the accelerator is almost the experiment. Indeed some of the questions require machines beyond our present capability. As this volume attests, there are parts of the particle physics program that have been significantly advanced without the use of accelerators such as the subject of neutrino oscillations and many aspects of the particle-cosmology interface. At this ...

2001-12-19

191

Effect of gasoline octane quality on vehicle acceleration performance  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted under the auspices of the Coordinating Research Council, Inc. (CRC) to assess the potential effects of gasoline octane quality on vehicle acceleration performance. Twelve participating laboratories, representing both the oil and the automotive industries, tested a total of 182 vehicles as part of the 1989 CRC Octane Number Requirement Survey. The vehicles consisted of 78 with electronic knock control systems and 104 without. All testing was performed using the 1989/1990 CRC FBRU fuel series. The results showed that acceleration performance of vehicles with knock sensors was significantly affected by gasoline octane quality. Octane effects on acceleration performance were most pronounced at maximum-throttle (detent) conditions and at octane levels below the vehicles' octane requirements; however, some knock-sensor vehicles did show improved acceleration performance with ...

1991-07-01

192

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

193

Hydrogen flame acceleration and transition to detonation  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-01-01

194

Hydrogen flame acceleration and transition to detonation  

International Nuclear Information System (INIS)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-10-23

195

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

196

An efficient higher order family of root finders  

British Library Electronic Table of Contents (United Kingdom)

A one parameter family of iterative methods for the simultaneous approximation of simple complex zeros of a polynomial, based on a cubically convergent Hansen-Patricks family, is studied. We show that the convergence of the basic family of the fourth order can be increased to five and six using Newtons and Halleys corrections, respectively. Since these corrections use the already calculated values, the computational efficiency of the accelerated methods is significantly increased. Further acceleration is achieved by applying the Gauss-Seidel approach (single-step mode). One of the most important problems in solving nonlinear equations, the construction of initial conditions which provide both the guaranteed and fast convergence, is considered for the proposed accelerated family. These cond...

2008-01-01

197

Why the US should spend billions on a new particle accelerator  

CERN Multimedia

"The US must develop a compelling bid to host the International Linear Collider in order to safeguard American science." (1,5 page)

2006-01-01

198

VOLUME I! - NASA Technical Report Server (NTRS)  

Science.gov (United States)

and propels the projectile to a velocity sufficient to reach ..... CLF3 + N2 4 .... 5 inches or greater accelerates a finned projectile to the veloc ...

199

Twenty Years of Tevatron Operation  

Energy Technology Data Exchange (ETDEWEB)

The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode, accelerating a proton beam into stationary targets/detectors, as well as a Colliding Beam mode, continuously colliding counter rotating beams of protons and antiprotons. Upon completion, the Tevatron cryogenic system became the world's largest helium refrigeration system. In 1993, the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history, experiences and statistics of the Tevatron, with an emphasis on the cryogenic system, is ...

2004-07-15

200

Spontaneous excitation of an accelerated atom in a spacetime with a reflecting plane boundary  

Science.gov (United States)

We study a two-level atom in interaction with a real massless scalar quantum field in a spacetime with a reflecting boundary. The presence of the boundary modifies the quantum fluctuations of the scalar field, which in turn modifies the radiative properties of atoms. We calculate the rate of change of the mean atomic energy of the atom for both inertial motion and uniform acceleration. It is found that the modifications induced by the presence of a boundary make the spontaneous radiation rate of an excited inertial atom oscillate near the boundary and this oscillatory behavior may offer a possible opportunity for experimental tests for geometrical (boundary) effects in flat spacetime. While for accelerated atoms, the transitions from ground states to excited states are found to be possible even in a vacuum due to changes in the vacuum fluctuations induced by both the presence of the boundary and the acceleration of atoms, ...

2005-09-15

201

Optimization for Vibration Isolation.  

Science.gov (United States)

An almost linear optimization problem of importance in vibration isolation has been identified and algorithms were developed to minimize the forced vibrational response of structural systems. The constraints can be either displacements of accelerations. T...

1983-01-01

202

Open-source software accelerates bioinformatics  

UK PubMed Central (United Kingdom)

A report on the Wellcome Trust/Cold Spring Harbor Genome Informatics meeting, Cold Spring Harbor, USA, 7-11 May 2003.

2003-01-01

204

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

205

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, ...

2010-01-01

206

Electromagnetic forming - a potentially viable technique for accelerator technology  

International Nuclear Information System (INIS)

Modern day accelerator development encompasses a myriad technologies required for their diverse needs. Whereas RF, high voltage, vacuum, cryogenics etc., technologies meet their functional requirements, high finish lapping processes, ceramic-metal joining, oven brazing, spark erosion or wire cutting etc., are a must to meet their fabrication requirements. Electromagnetic (EM) forming technique falls in the latter category and is developed as a special technology. It is currently catering to the development as a nuclear reactor technology, but has the potential to meet accelerator requirements too. This paper highlights the general principle of its working, simple design guidelines, advantages, and suggests some specific areas where this could benefit accelerator technologies

2003-02-03

207

ELECTROMAGNETIC AND THERMAL SIMULATIONS FOR THE SWITCH REGION OF A COMPACT PROTON ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

A compact proton accelerator for medical applications is being developed at Lawrence Livermore National Laboratory. The accelerator architecture is based on the dielectric wall accelerator (DWA) concept. One critical area to consider is the switch region. Electric field simulations and thermal calculations of the switch area were performed to help determine the operating limits of rmed SiC switches. Different geometries were considered for the field simulation including the shape of the thin Indium solder meniscus between the electrodes and SiC. Electric field simulations were also utilized to demonstrate how the field stress could be reduced. Both transient and steady steady-state thermal simulations were analyzed to find the average power capability of the switches.

2007-06-15

208

Development of mini-LIA and primary experiments  

International Nuclear Information System (INIS)

Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

2009-09-01

209

Deforestation in the Tropics  

Science.gov (United States)

Government policies that encourage exploitation--in particular excessive logging and clearing for ranches and farms--are largely to blame for the accelerating destruction of tropical forests. This paper surveys the problem in detail and briefly recommends potential solutions.

1990-04-01

210

Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results ...

1986-09-01

211

CERN scientists confront data deluge  

CERN Multimedia

The next generation of particle accelerator is currently being designed at CERN. An understanding of the market forces in the computer industry will play a crucial role in the success of the project.

1998-01-01

212

BC  

Wastenet

added to provide resistance to UV degradation, and vulcanization control. ...Sulphur is used to vulcanize the rubber ...additives and solvents age resistors, processing aids, accelerators, vulcanizing agents, softeners and fillers

213

Applied geodesy  

Energy Technology Data Exchange (ETDEWEB)

This volume is based on the proceedings of the CERN Accelerator School's course on Applied Geodesy for Particle Accelerators held in April 1986. The purpose was to record and disseminate the knowledge gained in recent years on the geodesy of accelerators and other large systems. The latest methods for positioning equipment to sub-millimetric accuracy in deep underground tunnels several tens of kilometers long are described, as well as such sophisticated techniques as the Navstar Global Positioning System and the Terrameter. Automation of better known instruments such as the gyroscope and Distinvar is also treated along with the highly evolved treatment of components in a modern accelerator. Use of the methods described can be of great benefit in many areas of research and industrial geodesy such as surveying, nautical and aeronautical engineering, astronomical radio-interferometry, metrology of ...

1987-01-01

214

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

215

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

216

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...

1991-11-01

217

Stereotactic body radiotherapy for unresectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A statistically significant association between ...

2010-01-01

218

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, ...

1981-11-01

219

Proximal cholangiocarcinoma. Prognostic factor and effectiveness of post operative radiotherapy  

International Nuclear Information System (INIS)

To define the prognostic factors after surgical resection and evaluate the effectiveness of Post Operative Radiotherapy (PORT) in cases with cholangiocarcinoma, 44 cases with proximal cholangiocarcinoma were examined. The mean observation period was 20.6 months, and the survival rates 1, 3 and 5 years after the resection were 79.9%, 59.8% and 39.3%, respectively. Univariate analysis revealed that the presence of lymph node metastasis and absence of PORT were significant poor prognostic factors. Multivariate analysis revealed that the absence of PORT was a significant poor prognostic factor. The survival rates for 1 and 3 years after the resection were 80.0% and 40.0% in the curable A/B and PORT (-) group, and 100% and 53.3% in curable C and PORT (+) group. There were no local reccurences in the pathologically classified hm2 and em2 patients who underwent PORT. Even when the surgical margin is positive for the carcinoma pathologically, it is possible to avoid local ...

2000-10-01

220

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of non-malignant diseases because ...

1983-01-01

221

Local control and survival of Ewing's sarcoma in children with radiotherapy and chemotherapy without radical surgery  

International Nuclear Information System (INIS)

The present study was undertaken in 27 children with localized Ewing's sarcoma treated at our hospital. In 9 cases the lesion was central and in 18 peripheral. Treatment consisted of: 1) Chemotherapy with 6 drugs (vincristine, cyclophosphamide, methotrexate, bleomycin, dactinomycin and doxorubicin) for one year in all patients; 2) Radiotherapy in 24 patients at a dose of 30-40 Gy in the entire bone with a booster dose of 10-15 Gy in the lesion. In 7 patients debulking surgery was performed followed by irradiation. Two cases with tumor in expendable bones and one with extensive destructive lesion in the tibia underwent radical surgery. One patient suffered local recurrence (femur) and 6 developed distant metastases. The remaining 20 (74%) patients were alive and tumor-free after follow-up periods of 17-80 months. Among the 12 patients with extremity lesions who were alive, 7 (58%) had minimal or mild treatment sequelae, 2 moderate, and 3 severe sequelae but no ...

222

Lessons drawn from the accidents occurred in the framework of conventional external radiotherapy;Lecons tirees des accidents survenus dans le cadre de la radiotherapie externe conventionnelle  

Energy Technology Data Exchange (ETDEWEB)

This study examines some radiation accidents occurred in the past. This information has been systematically assessed to get global lessons. The experience feedback shows that the most of accidents happened in certain conditions. These conditions can be distributed in four categories: 1- perception and vigilance in occupation: accidental exposure happened by lack of vigilance in details and lack of vigilance and perception; 2- procedures: accidental exposure happened following a lack of procedures or control that were not enough complete, not enough documented or not completely implemented; 3- training and understanding: accidental exposures happened because the personnel was not enough qualified and educated, did not get the general training nor the the necessary specialized training; 4- liabilities: accidental exposures happened following lacks and ambiguity in the definition of functions of the personnel and in the hierarchy liabilities. In these precise cases the safety tasks have ...

2009-12-15

223

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...

224

Intracavity irradiation with deferred radioactive load technique, remote control high activity sources  

Energy Technology Data Exchange (ETDEWEB)

From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant ...

1988-01-01

225

Hyperfractionated radiotherapy with simultaneous chemotherapy in Ewing's sarcoma  

International Nuclear Information System (INIS)

In 1981, the German Society of Pediatric Oncology initiated a multi-institutional study for the treatment of Ewing's sarcoma. The protocol (Cooperative Ewing's Sarcoma Study, CESS 81) consisted of four courses of a four-drug-regimen (VACA), each course taking nine weeks. Local therapy (radical surgery or resection plus irradiation or radiotherapy alone) was performed after the second course. The results of CESS 81 can be summarized as follows: VACA-chemotherapy is effective in controlling systemic disease. Initial tumor mass and response to initial chemotherapy are of major prognostic value for local control and survival. Permanent local control is a problem, especially in irradiated patients. The high local failure rate in irradiated patients in CESS 81 could be attributable to the following reasons: Late start of local therapy (after 18 weeks of chemotherapy), uneven distribution of prognostic parameters: Large tumors were more often irradiated than operated, ...

226

Ewing's sarcoma. Evaluation of radiotherapy and control of the primary tumor  

International Nuclear Information System (INIS)

From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).

227

Bilateral femoral neck fractures following pelvic irradiation  

International Nuclear Information System (INIS)

Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was ...

228

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

229

The reirradiation of the cavum cancer. Experience of the oncology center Ibn-Rochd of Casablanca (C.O.I.R.); La reirradiation du cancer du cavum. Experience du centre d'oncologie Ibn-Rochd de Casablanca (COIR)  

Energy Technology Data Exchange (ETDEWEB)

The radiotherapy is the prime treatment for the cavum cancer. It is also useful to treat the tumor recurrences, in this case the reirradiation stays the only efficient therapy option to give a correct local control. The reirradiation, exclusive or in association with other therapies can contribute to the local control of cavum cancer recurrences with a survival rate at five years of 36 to 58%. (N.C.)

2006-11-15

230

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers and physicians. (author)

231

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

232

Palliation of radiation-related mucositis  

Energy Technology Data Exchange (ETDEWEB)

Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.

1990-01-01

233

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

234

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They were enrolled on ...

2000-01-15

235

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

236

Computer-assisted rotation and multiple stationary irradiation technique  

International Nuclear Information System (INIS)

A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).

237

Acute lymphoblastic leukemia with multiple cytogenetic abnormalities secondary to treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-06-01

238

A case of Ewing's sarcoma treated successfully with chemotherapy and radiotherapy  

International Nuclear Information System (INIS)

We encountered a case of Ewing's sarcoma. The patient was a 19 year-old girl, who visited a local physician because of pain in the left scapular region, and was referred to us. Roentgenograms of her left scapula revealed an irregular moth-eaten shadow which was suspected to be a malignant bone tumor. The histological diagnosis of Ewing's sarcoma was comfirmed by needle biopsy. The initial stage of treatment consisted of radiation therapy (6000 rads) and chemotherapy (VAC and ADR). At the end of the initial stage, the symptoms were improved, the size of the local lesion was reduced on the roentgenogram and there was no evidence of distant metastases. (author).

239

Semi-automated segmentation of the sigmoid and descending colon for radiotherapy planning using the fast marching method  

International Nuclear Information System (INIS)

A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon centre line between ...

2010-09-21

240

Radiotherapy for brain metastases from renal cell cancer. Should whole-brain radiotherapy be added to stereotactic radiosurgery? Analysis of 88 patients  

International Nuclear Information System (INIS)

Purpose: To evaluate the role of stereotactic radiosurgery (SRS) and whole-brain radiotherapy (WBRT) for the treatment of brain metastases in patients with renal cell cancer (RCC). Patients and methods: 88 patients were treated with either SRS (n = 51) or SRS + WBRT (n = 17) for one to three lesions, or with WBRT (n = 20) for more than three brain metastases. Overall survival (OS), intracerebral control (IC) and local control (LC) were retrospectively analyzed. Six potential prognostic factors were assessed: age, gender, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Results: The median times for OS, IC, and LC from the time of diagnosis were 11, 9, and 10 months. The median OS times for SRS, SRS + WBRT, and WBRT were 12, 16, and 2 months. Addition of WBRT to the SRS improved IC (p = 0.032) but not OS (p = 0.703). On multivariate analyses, improved OS was ...

2010-04-01

241

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority ...

2006-02-01

242

Phase I Study of Conformal Radiotherapy and Concurrent Full-Dose Gemcitabine with Erlotinib for Unresected Pancreatic Cancer.  

Science.gov (United States)

PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting toxicity, except for Grade 3 anorexia or Grade 3 fatigue alone. RESULTS: A total of 20 patients were ...

2011-05-01

243

Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice  

International Nuclear Information System (INIS)

A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse cytophotometry, "3H-thymidine uptake labeling ...

244

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E/sub ...

1981-12-01

245

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E2 (19 +/- 8 ...

1981-12-01

246

Concurrent Chemoradiotherapy in Resected Extrahepatic Cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: Extrahepatic cholangiocarcinoma is a rare malignancy. Despite radical resection, survival remains poor, with high rates of local and distant failure. To clarify the role of radiotherapy with chemotherapy, we performed a retrospective analysis of resected patients who had undergone chemoradiotherapy. Methods and Materials: A total of 45 patients (13 with proximal and 32 with distal disease) underwent resection plus radiotherapy (median dose, 50.4 Gy). All but 1 patient received concurrent fluoropyrimidine-based chemotherapy. The median follow-up was 30 months for all patients and 40 months for survivors. Results: Of the 45 patients, 33 underwent adjuvant radiotherapy, and 12 were treated neoadjuvantly. The 5-year actuarial overall survival, disease-free survival, metastasis-free survival, and locoregional control rates were 33%, 37%, 42%, and 78%, respectively. The median survival was 34 months. No patient died ...

2009-01-01

247

The physics of tachyons. Pt. 2  

International Nuclear Information System (INIS)

This paper extends the development of a new formulation of the theory of tachyons to encompass the dynamics of tachyons. Energy and momentum are discussed along with the proper mass of a tachyon. The transformation of force in extended relativity (ER) is derived. Acceleration in ER is also discussed, as well as the relationship between force and acceleration. Two simple examples relating to the motion of a charged tachyon are discussed, followed by a brief explanation of why tachyons cannot emit Cerenkov radiation in a vacuum. 13 refs., 3 figs.

248

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

249

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

250

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

251

The Darmstadt near-infrared free-electron laser  

International Nuclear Information System (INIS)

The salient features of the near-infrared free-electron laser (FEL) that is under construction at the new Darmstadt superconducting 130-MeV electron accelerator are discussed. Special attention is given to the layout and the parameters of the accelerator, the layout of the planned FEL experiment, the characteristics of the electron gun, the subharmonic chopper-buncher system, and the hybrid undulator system of the Darmstadt FEL. A comparison of the planned Darmstadt FEL with conventional lasers, with respect to the pulse and wavelength region, is presented. 15 refs.

1989-04-24

252

Tachyons and the radiation of an accelerated charge  

Energy Technology Data Exchange (ETDEWEB)

The motion of an accelerated charge in a vacuum is analyzed, via the superposition principle and Fourier analysis, into uniform-motion components, which include bradyonic as well as tachyonic contributions. It is shown that the former contribute only to the induction fields whereas the latter are the source of the radiation emitted by the charge, via the Sommerfeld-Cerenkov mechanism. This result calls for a reexamination of some recently formulated theories of superluminal particles.

1982-10-15

253

Structure of an accelerator island with one step on double period of conserving area mapping  

International Nuclear Information System (INIS)

The structure of the P-2, S-1 accelerator mode with one step, S-1, on double period, P-2 for systems, described by the Harper mapping as well as by standard mapping, is analyzed. Detailed analysis of stability criteria is given and comparison with the results of numerical analysis is performed. Three-period compression of the P-2, S-1 island is revealed in the standard mapping. Refs. 7, figs. 7.

254

Recent developments in nuclear data for ADS  

Energy Technology Data Exchange (ETDEWEB)

Modern particle accelerators offer new opportunities to dramatically reshape the way we think about nuclear energy, and challenge some of the thorniest problems linked to its industrial use, e.g. nuclear waste. A powerful proton accelerator driving a sub-critical fission reactor could be used for producing energy more safely and burning up the extra spent fuel which so far has been stored in geological repositories.

2001-01-01

255

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

256

Particle acceleration by stimulated emission of radiation near a solid-state active medium  

British Library Electronic Table of Contents (United Kingdom)

We report acceleration of electrons moving in free space near an active Nd:YAG slab. The power of a non-relativistic beam of electrons has increased by more than 30% when the medium was excited. It is demonstrated experimentally that the energy gained by the electrons is linearly proportional to the energy stored in the medium. Moreover, the energy gain traces closely the population inversion inferred by monitoring the spontaneous radiation.

2011-01-01

257

On-line replacement of a particle accelerator control computer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the conversion from an existing production control computer, an SEL 840, to a DEC VAX 11/780. The plan is to add a layer of hardware to accomplish a smooth and gradual transition from the 840 to the VAX while leaving the underlying equipment unchanged. The architecture of the control system software is discussed for a large linear accelerator from the standpoint of its requirements and the particular design philosophy chosen.

1981-01-01

258

Long term accelerated aging tests on distribution cables under wet conditions  

Energy Technology Data Exchange (ETDEWEB)

Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.

1996-10-01

259

JAERI TANDEM annual report 2000. April 1, 2000 - March 31, 2001  

Energy Technology Data Exchange (ETDEWEB)

This annual report describes research activities which have been performed with the JAERI tandem accelerator and the Van de Graaff accelerator from April 1, 2000 to March 31, 2001. Summary reports of 46 papers, and lists of publication, personnel and cooperative research with universities are contained. (author)

2001-11-01

260

High-brightness photoemitter development for electron accelerator injectors  

Energy Technology Data Exchange (ETDEWEB)

Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.

1985-01-01

261

Evaluation of high temperature accelerated aging tests used on integrated circuits. Final report  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests such as high temperature burn-in, which are in current use on Bendix Kansas City Division's (BKC) purchased small and medium scale integrated circuits, were evaluated to determine if they are effective and necessary to ensure the required reliability. A theoretical analysis, a literature search, and a study of lot acceptance results were used to assess the value of integrated circuit burn-in.

1986-04-01

262

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

263

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

264

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

265

Early Experience in Using an 18 MeV Linear Accelerator for Mycosis Fungoides at Howard University Hospital  

UK PubMed Central (United Kingdom)

This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeV electron capability, for total skin irradiation for mycosis fungoides. The 6 MeV electron energy...Full Text Available

1977-04-01

266

Decay-accelerating factor CD55 is identified as the receptor for echovirus 7 using CELICS, a rapid immuno-focal cloning method.  

UK PubMed Central (United Kingdom)

Using an anti-receptor mAb that blocks the attachment of echovirus 7 and related viruses (echoviruses 13, 21, 29 and 33), we have isolated a complementary DNA clone that encodes the human decay-accelerating...Full Text Available

1994-11-01

267

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

268

Cosmological BCS condensate as dark energy  

CERN Document Server

We argue that the occurrence of late-time acceleration can conveniently be described by first-order general relativity covariantly coupled to fermions. Dark energy arises as a gravitationally driven BCS condensate of fermions which forms in the early universe. At late times, the gap and chemical potential evolve to have an equation of state with effective negative pressure, thus naturally leading to acceleration.

2009-01-01

269

Contribution of pulsars to the cosmic rays in the Galaxy  

Energy Technology Data Exchange (ETDEWEB)

The contribution of pulsar accelerated nuclei to the cosmic rays inside the Galaxy is calculated assuming that a significant part of the pulsar rotational energy is lost on acceleration of iron nuclei extracted from the surface of the neutron star. Different models of the galactic pulsar population are discussed. It is shown that the best description of the observed cosmic ray spectrum and the mass composition between a few 10{sup 15} eV and a few 10{sup 18} eV is obtained for the model B of Lorimer et al. (1993)

2004-11-15

270

Computer modeling of two-phase flow  

Science.gov (United States)

The accelerating flow of a lighter continuous phase through a heavier one is considered. Small nonuniformities grow into large ones due to the Rayleigh-Taylor instability. An experiment exemplifying the large bubble formation due to Rayleigh-Taylor instability was performed and simulated using the PHOENICS 84 computer code. The same numerical procedure was applied to the two-phase flow in a gun barrel. It shows that the acceleration provided by the movement of the projectile can cause initial nonuniformities to grow with time.

1986-10-01

271

Assessment of the efficacy of braking radiation beam formation of electron accelerators  

International Nuclear Information System (INIS)

Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.

272

Annotated bibliography of Accelerator Technology Division research and development, 1978-1985  

International Nuclear Information System (INIS)

A bibliography is presented of unclassified published and in-house technical material written by members of the Accelerator Technology Division, Los Alamos National Laboratory, since its inception in January, 1978. The author and subject concordances in this report provide cross-reference to detailed citations kept in a computer database and a microfilm file of the documents. The citations include an abstract and other notes, and can be searched for key words and phrases.

273

Analysis of longitudinal bunching in an FEL driven two-beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

2000-08-01

274

An S-brane solution with acceleration and small enough variation of G  

CERN Document Server

An S-brane solution with two non-composite electric branes and a set of l scalar fields is considered. The intersection rule for branes corresponds to the Lie algebra A_2. The solution contains five factor spaces with the fifth one interpreted as ``our'' 3-dimensional space. It is shown that there exists a time interval where accelerating expansion of ``our'' 3-dimensional space is compatible with small enough value of effective gravitational ``constant'' variation.

2007-01-01

275

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

276

Accelerating the convergence of self-consistent linearized augmented-plane-wave calculations  

International Nuclear Information System (INIS)

The applicability of Broyden's second method for accelerating the convergence of self-consistent electronic-structure calculations based on the linearized augmented-plane-wave method is discussed in terms of a W(001) surface calculation. It is found that its use results in a significant improvement in the convergence of the calculation, and based on this it is concluded that its use should increase the size of the systems for which such calculations are feasible.

277

Accelerated aging tests with a resid hydrotreating catalyst  

International Nuclear Information System (INIS)

The author discusses the accelerated aging tests performed using Hondo and Maya as aging resids with a commercial large pore hydrotreating catalyst. The results from these tests were compared with those obtained under a normal full life test. The test resid was a sample of a typical refinery charge and the activities for sulfur and vanadium removal were determined at 720"0F after successive brief periods of exposure to the heavier oils.

1988-12-02

278

Accelerated aging speeds test of instrument reliability  

International Nuclear Information System (INIS)

Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.

1982-01-01

279

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood; Aktuelle und zukuenftige Strategien in der interdisziplinaeren Therapie von Medulloblastomen, supratentoriellen PNET und intrakraniellen Keimzelltumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting ...

2001-09-01

280

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the ...

2010-01-01

281

Multi-beamlet focusing of intense negative ion beams by aperture displacement technique  

Energy Technology Data Exchange (ETDEWEB)

Multi-beamlet focusing of an intense negative ion beam has been performed using the beamlet steering by the aperture displacement. The apertures of the grounded grid were displaced as all beamlets of 270 (18 x 15) in the area of 25 cm x 26 cm would be steered to a common point (a focal point) in both the two-stage and the single-stage accelerators. The multi-beamlets were successfully focused and the e-folding half width of 10 cm was achieved 11.2 m downstream from the ion source in both the accelerators. The corresponding gross divergence angle is 9 mrad. The negative ion beamlets are deflected by the magnetic field for the electron deflection at the extraction grid and the deflection direction oppositely changes line by line, resulting in the beam split in the deflection direction. This beamlet deflection was well compensated also using the beamlet steering by the aperture displacement of the grounded grid. The beam ...

1995-08-01

282

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from ...

1994-01-01

283

Lie Algebraic Treatment of Linear and Nonlinear Beam Dynamics  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to present a summary of new methods, employing Lie algebraic tools, for characterizing beam dynamics in charged-particle optical systems. These methods are applicable to accelerator design, charged-particle beam transport, electron microscopes, and also light optics. The new methods represent the action of each separate element of a compound optical system, including all departures from paraxial optics, by a certain operator. The operators for the various elements can then be concatenated, following well-defined rules, to obtain a resultant operator that characterizes the entire system. This paper deals mostly with accelerator design and charged-particle beam transport. The application of Lie algebraic methods to light optics and electron microscopes is described elsewhere (1, see also 44). To keep its scope within reasonable bounds, they restrict their treatment of accelerator design and ...

1988-12-01

284

The optimal path of piston motion for Otto cycle with linear phenomenological heat transfer law  

British Library Electronic Table of Contents (United Kingdom)

An Otto cycle engine with internal and external irreversibilities of friction and heat leakage, in which the heat transfer between the working fluid and the environment obeys linear phenomenological heat transfer law [q ?? ?(T ?1)], is studied in this paper. The optimal piston motion trajectory for maximizing the work output per cycle is derived for the fixed total cycle time and fuel consumed per cycle. Optimal control theory is applied to determine the optimal piston trajectories for the cases of with and without piston acceleration constraint on each stroke and the optimal distribution of the total cycle time among the strokes. The optimal piston motion with acceleration constraint for each stroke consists of three segments, including initial maximum acceleration and final maximum decel...

2009-01-01

285

The new Tevatron beam position monitor front-end software  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron is a proton anti-proton accelerator collider operating at the Fermi National Accelerator Laboratory. The machine is currently delivering beam for the CDF and D0 experiments, which expect increasing luminosity until the conclusion of Run II, planned for 2009. The Laboratory defined a plan for achieving higher luminosity, and one of the tasks is the upgrade of the accelerator's beam position monitor (BPM). The Tevatron was built during the early eighties and some of its control systems, including the BPMs, are still the original ones. This paper describes the front-end software of the Tevatron BPM upgrade, from the requirements to the implementation, and the underlying hardware setup. The front-end software designed is presented, emphasizing its modularity and reusability, allowing it to be applied to other Fermilab machines.

2005-05-01

286

The Physics of Cosmic Acceleration  

CERN Document Server

The discovery that the cosmic expansion is accelerating has been followed by an intense theoretical and experimental response in physics and astronomy. The discovery implies that our most basic notions about how gravity work are violated on cosmological distance scales. One simple fix is the introduction of a cosmological constant into the field equations for general relativity. However, the extremely small value of the cosmological constant, relative to theoretical expectations, has led theorists to explore a wide variety of alternative explanations that involve the introduction of an exotic negative-pressure fluid or a modification of general relativity. Here we briefly review the evidence for cosmic acceleration. We then survey some of the theoretical attempts to account for it, including the cosmological constant, quintessence and its variants, mass-varying neutrinos, and modifications of general relativity, such as scalar-tensor and $f(R)$ ...

2009-01-01

287

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the ...

2002-01-01

288

State-of-the-Art developments in accelerator controls at the APS.  

Energy Technology Data Exchange (ETDEWEB)

The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control system of any size ...

1999-04-13

289

Standing-Wave Free-Electron Laser Two-Beam Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set.

1991-02-01

290

Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 5  

Energy Technology Data Exchange (ETDEWEB)

This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory Editing and changes to the authors` contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on nine presentations: ``The Energy Exchange and Efficiency Consideration in Klystrons``, ``Some Properties of Microwave RF Sources for Future Colliders + Overview of Microwave Generation Activity at the University of Maryland``, ``Field Quality Improvements in Superconducting Magnets for RHIC``, ``Hadronic B-Physics``, ``Spiking Pulses from Free Electron Lasers: Observations and Computational Models``, ``Crystalline Beams in Circular Accelerators``, ``Accumulator Ring for AGS & Recent AGS Performance``, ``RHIC Project Machine Status``, and ``Gamma-Gamma Colliders.``

1995-10-01

291

Radioanalytical study of the chromate conversion coating formed on aluminium  

Energy Technology Data Exchange (ETDEWEB)

Phosphate/chromate and accelerated chromate coatings were produced on commercially available aluminium. The Cr, P and Fe components of the conversion coatings were determined by radioactive tracer technique. The tracer technique was combined with ion-exchange and film-sectioning methods to determine the chromium(III)/total chromium ratio in the accelerated chromate coating. It was found that during the acidic dissolution of the conversion coating the chromium(III)/total chromium ratio may suffer changes. The film-forming components in the metal/bath interface are supersaturated and deposited onto the aluminium. The identified components of the accelerated chromate coatings are Cr(OH)sub(3), Cr(OH)CrOsub(4) and Crsub(4)(Fe(CN)sub(6))sub(3) and the chromium(III)/total chromium ratio was found to be cca. 2/3. (author). 11 refs.; 5 figs.

1985-09-16

292

Polarized electron sources  

Energy Technology Data Exchange (ETDEWEB)

Polarized electron sources for high energy accelerators took a significant step forward with the introduction of a new laser-driven photocathode source for the SLC in 1992. With an electron beam polarization of >80% and with {approximately}99% uptime during continuous operation, this source is a key factor in the success of the current SLC high-energy physics program. The SLC source performance is used to illustrate both the capabilities and the limitations of solid-state sources. The beam requirements for future colliders are similar to that of the SLC with the addition in most cases of multiple-bunch operation. A design for the next generation accelerator source that can improve the operational characteristics and at least minimize some of the inherent limitations of present sources is presented. Finally, the possibilities for producing highly polarized electron beams for high-duty-factor accelerators are discussed.

1995-05-01

293

Operating experience with a new accelerator control system based upon microprocessors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

1981-03-01

294

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed ...

2004-04-01

295

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented ...

2010-11-11

296

Mineral carbonation accelerated by dicarboxylic acids as a disposal process of carbon dioxide  

British Library Electronic Table of Contents (United Kingdom)

Mineral carbonation is based on the reaction of carbon dioxide with metal-oxide bearing minerals, usually containing magnesium or calcium silicate, to form hardly soluble carbonates and other solid byproducts. The concept is based on acceleration of the naturally occurring rock weathering process. In the present work the calcium silicate is present in the mineral, wollastonite. To accelerate the process and make it potentially useful for practical applications, mineral carbonation is conducted here using an indirect two-step route in which the reactive component (Ca^2^+ ions in considered case) is first extracted from the mineral matrix and afterwards carbonated. Two solid byproducts are formed in this process: silica in the extraction step and calcium carbonate in the carbonation step. In...

2011-01-01

297

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

298

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

299

Evaluation of HVDC cables for the St. Lawrence crossing of Hydro-Quebec 500 kV DC Line. Part 1; Dielectric and accelerated aging tests on prototypes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.

1992-04-01

300

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

1998-01-01

301

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

1998-10-13

302

Coherent Smith-Purcell radiation in the far-infrared region from a short-bunched electron beam  

International Nuclear Information System (INIS)

Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.

1995-09-28

303

Case study: Accelerated schedule for MULTI LIMS installation  

Energy Technology Data Exchange (ETDEWEB)

This presentation focuses on the steps taken by the Westinghouse Hanford Company to meet an accelerated schedule for configuration and implementation of the MULTI LIMS in a multiple laboratory environment. The Westinghouse Hanford Company purchased the MULTI LIMS Laboratory Information Management System in August, 1993. Hardware delivery began in October, 1993. Less than four months later, the initial configuration was released for use in two Westinghouse Hanford Company laboratories. Several major obstacles were overcome during implementation. These include information gathering for base table loading, user training, acceptance of the new system by users of a legacy system, and hardware configuration issues. In summary, steps needed to be taken to meet the accelerated implementation schedule of the MULTI LIMS at the Hanford Site. The obstacles faced were overcome through the in-depth knowledge and help of the vendor and the dedication and ...

1994-05-01

304

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton beam from the Tevatron collider.

1999-01-01

305

Accelerator mass spectrometry: state of the art  

Energy Technology Data Exchange (ETDEWEB)

Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

1996-12-31

306

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

307

Accelerated aging speeds test of instrument reliability  

International Nuclear Information System (INIS)

This paper shows how molecular theory paves the way for accelerated aging tests of safety-related equipment in nuclear power plants, as required by NRC qualification programs. Arrhenius' model, based on an equation, provides useful information regarding the extent of molecular change as a function of time and temperature. Critical to determining the aging characteristics and qualified life of organic materials is the activation energy concept, which is derived from information gathered when the molecular reaction of the material is documented over the entire life cycle. In accelerated-aging applications, the importance of the model lies in characterizing the chemical related reactions of materials. The problem with the Arrhenius approach is that, in generating a testing period of reasonable duration, a rather high test temperature must be selected which may lead to an added and unrelated environmental effect.

1982-01-01

308

Accelerated aging of catalytically airblown asphalt membranes under simulated uranium mill tailings impoundment conditions  

International Nuclear Information System (INIS)

This paper evaluates the performance of asphalt membranes by examining the chemical and permeability changes experienced by the asphalt during aging tests. The aging process was accelerated by exposing the asphalt to elevated temperatures, high oxygen concentrations, and increased strengths of aqueous oxidizing agents. The synergistic effects of the variables are evaluated by using a fractional factorial experimental design. The installation costs for a catalytically airblown asphalt liner are roughly half that of the typical polymeric materials, and also less than the rubberized asphalt membrane. The results of the initial accelerated aging tests of the asphalt membranes indicate that this material will provide stable, long-term leachate isolation in a mill tailings environment.

1982-12-01

309

Accelerated aging corrosion tests for buried metal structures  

Energy Technology Data Exchange (ETDEWEB)

It is necessary to identify those measurable soil parameters which dictate the severity of the corrosion problem for coated irons and steels. When this is done, meaningful accelerated aging tests can be designed to validate the reduced corrosion rate for the planned coating. The following discussion introduces the important concepts and measurement parameters in the (a) design of accelerated aging tests, and (b) evaluation of the planned installation site for corrosion potential. Certain combinations of soil oxidation reduction potential (ORP) or electric potential (Eh), acidity (pH), fertilizer, water table, and soil hydraulic conductivity can result in severe corrosion of buried steel/iron vessels. If there are power lines nearby, additional loss of vessel material to the soil will occur. These factors are discussed.

1996-10-01

310

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01

311

(International Panel on 14 MeV Intense Neutron Source Based on Accelerators for Fusion Materials Study)  

Energy Technology Data Exchange (ETDEWEB)

Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.

1991-02-14

312

Second malignancies after treatment for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: Some former retrospective studies have suggested that patients with Ewing's sarcoma might have a very high risk for developing secondary sarcomas if treated with radiotherapy. We have evaluated the risk of second malignancies (SM) in patients treated in the German Cooperative Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and methods: From January 1981 through June 1991, a total number of 674 patients was registered in the two multicentric Ewing's sarcoma trials CESS 81 (1981 through 1985) and CESS 86 (1986 through June 1991). The systemic treatment consisted in both studies of a four-drug-chemotherapy (VACA= vincristine, actinomycin D, cyclophosphamide and adriamycin; or VAIA= vincristine, actinomycin D, ifosfamide and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy was either complete surgery or surgery plus postoperative radiotherapy with 36-46Gy or ...

313

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

314

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for implementing a dose ...

2003-01-01

315

Surgical management of osteoradionecrosis of the temporal bone  

Energy Technology Data Exchange (ETDEWEB)

The surgical management of osteoradionecrosis of the temporal bone has met with limited success because of the difficulty in accurate assessment of the viability of nonnecrotic bone intraoperatively. Failure to resect all nonviable bone results in recurrence of a necrotic focus. With the use of hyperbaric oxygen therapy to stabilize marginal bone and oral tetracycline to label viable bone preoperatively, removal of all nonviable bone can be accomplished. Postoperatively, a second course of hyperbaric therapy enhances wound healing, thus assuring a successful outcome. This article details a successful systematic approach that was developed to resect a necrotic focus in the temporal bone of a 10-year-old boy who had undergone a full course of radiotherapy for treatment of a rhabdomyosarcoma.

1988-03-01

316

Surgical aspects of intestinal injury due to pelvic radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.

1985-04-01

317

Second malignancies after treatment for Ewing's sarcoma: a report of the CESS-studies  

International Nuclear Information System (INIS)

Purpose: During recent years, more intensified systemic and local treatment regimens have increased the 5-year survival figures in localized Ewing's sarcoma to more than 60%. There is, however, concern about the risk of second malignancies (SM) in long-term survivors. We have analyzed the second malignancies in patients treated in the German Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and Methods: From January 1981 through June 1991, 674 patients were registered in the two sequential multicentric Ewing's sarcoma trials CESS 81 (recruitment period 1981-1985) and CESS 86 (1986-1991). The systemic treatment in both studies consisted of a four-drug-regimen (VACA = vincristine, actinomycin D, cyclophosphamide, and adriamycin; or VAIA = vincristine, actinomycin D, ifosfamide, and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy in curative patients was either complete surgery (n = 162), surgery plus ...

1998-09-01

318

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

319

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

320

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 tabs., 138 refs.

1988-01-01

321

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a patient and deposited in a phantom at a large ...

2004-12-01

322

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

323

Optimizing the conditioning regimen for allogeneic stem-cell transplantation in acute myeloid leukemia; dose intensity is still in need  

British Library Electronic Table of Contents (United Kingdom)

Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...

2011-01-01

324

Oligodendroglioma occurring after radiation therapy for pituitary adenoma  

Energy Technology Data Exchange (ETDEWEB)

A 38 year old male dentist developed an oligodendroglioma of the left medial temporal lobe and parasellar region 12 years after radiotherapy with 6600 rads for acromegaly. The 30 cases of radiation-induced gliomas reported in the English literature are reviewed and analysed. The criteria for defining radiation-induced tumours of the central nervous system are proposed as follows: the tumour has a long quiescent ''latency period'', a location in the previously irradiated field, a verified histological difference from a primary condition, and does not arise from a primary condition associated with a genetic syndrome such as neurofibromatosis or tuberous sclerosis. The reported case fulfilled these criteria but appears to be the only reported radiation-induced oligodendroglioma.

1987-12-01

325

New procedures. Comprehensive staging of lung cancer by MRI  

International Nuclear Information System (INIS)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.)

2010-08-01

326

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.

327

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

328

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

329

Ewing's Sarcoma : a study of 38 cases  

International Nuclear Information System (INIS)

A retrospective study of Ewing's Sarcoma at The Armed Forces Malignant Diseases Treatment Centre, Command Hospital, Pune, is presented. A total of 38 cases over a period of thirteen years have been studied. Males predominate slightly, and the common age group on presentation has been in the second and third decade. Humerus, pelvis and femur are the bones commonly affected. The initial line of management has been primarily radiotherapy, which has been over the years supplemented by combination chemotherapy. All the cases achieved remission, though only 32 cases (84 per cent) had complete remission, and the remaining only partial remission. The overall survival in those offered aggressive therapy has been over 50 per cent in two years. The present policy in the management of these cases is discussed. (author). 4 tabs.

330

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

331

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

332

Chemoradiotherapy of unresectable and recurrent cholangiocarcinoma  

International Nuclear Information System (INIS)

This study is for chemoradiotherapy of unresectable and recurrent cholangiocarcinoma (CCC). Between April 2005 and March 2007, 5 patients were evaluated for unresectable and recurrent CCC. All patients were performed percutaneous transhepatic biliary drainage (PTBD) and treated with chemoradiotherapy. The radiation method was an external beam radiotherapy (EBRT) and remote after loading system (RALS). The chemotherapy was 5-fluorouracil (FU) and gemcitabine by intravenous injection. Three patients had unresectable and 2 had recurrent CCC. As for the side effects, 4 patients had a slight neutropenia and 1 had an uncontrollable gastric bleeding. No patient had cholangitis. The mean survival time for unresectable and recurrent CCC was 13.7 months and 17 months, respectively. Our results indicated that chemoradiotherapy had been consistent with efficacy in patients with unresectable and recurrent CCC. (author)

2007-11-01

333

Alpha particles for treatment of disseminated melanoma  

International Nuclear Information System (INIS)

Invading melanoma spreads to local and unpredictable distant location at the early stages of its development. It is justifiable, therefore, to classify the disease as a systemic disorder. This requires a systemic treatment that reaches all melanoma cells irrespective of whether they are singly dispersed and in circulation or already forming solid tumours of various sizes. Targeted radiotherapy affects directly and selectively cancer cells provided an appropriate radionuclide and its carrier are chosen. Melanoma is a pigmented tumour. Methylene blue (MTB)) accumulates selectively in melanoma cells due to its exceptionally high affinity to melanin. MTB serves, therefore, as a carrier for radionuclides. "2"1"1At-MTB has proved to be particularly effective in treating disseminated melanoma when administered systemically and, at the same time, non-toxic to normal non-pigmented and pigmented organs. (authors)

334

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

335

The two-beam accelertor  

Energy Technology Data Exchange (ETDEWEB)

The Two-Beam Accelerator (TBA) consists of a long high-gradient accelerator structure (HGS) adjacent to an equal-length Free Electron Laser (FEL). In the FEL, a beam propagates through a long series of undulators. At regular intervals, waveguides couple microwave power out of the FEL into the HGS. To replenish energy given up by the FEL beam to the microwave field induction accelerator units are placed periodically along the length or the FEL. In this manner it is expected to achieve gradients of more than 250 MV/m and thus have serious option for a 1 TeV /times/ 1 TeV linear collider. The state of present theoretical understanding of the TBA is presented with particular emphasis upon operation of the ''steady-state'' FEL, phase and amplitude control of the rf wave, and suppression of sideband instabilities. Experimental work has focused upon the development of a suitable HGS and the ...

1987-08-01

336

The Fermilab Linac Upgrade  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Linac Upgrade is planned to increase the energy of the H- linac from 200 to 400 MeV. This is intended to reduce the incoherent space-charge tuneshift at injection into the 8 GeV Booster which can limit either the brightness or the total intensity of the beam. The Linac Upgrade will be achieved by replacing the last four 201.25 MHz drift-tube tanks which accelerate the beam from 116 to 200 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of abut 7.5 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. Each accelerator module will be driven with a klystron-based rf power supply. A prototype rf modulator has been built and tested at Fermilab, and a prototype 12 MW klystron is being fabricated by Litton Electron Devices. Fabrication of production accelerator modules is in progress. 8 figs., 4 tabs.

1991-02-01

337

Superheavy elements - the quest in perspective  

International Nuclear Information System (INIS)

A review is presented of the quest for superheavy elements under the following headings - early history; physical and nuclear properties unique to superheavy elements; searches in nature; terrestrial samples; extra-terrestrial samples; and searches at accelerators. 72 references. (U.K.).

338

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

339

Stimulation of Phosphatidylethanolamine Exchange by Castor Bean Cytosol Proteins 1  

UK PubMed Central (United Kingdom)

Cytosol proteins prepared from castor bean endosperm (4-day-old) seedlings stimulate the exchange of [3H]phosphatidylethanolamine between liposomes and mitochondria. The acceleration of the...Full Text Available

1980-02-01

340

Status of the Lawrence Berkeley Laboratory and Lawrence Livermore National Laboratory free electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

A description of the FEL experiment underway at the 10 kA, 5 MeV Experimental Test Accelerator (ETA) is described. The facility has been designed to investigate the high-gain operation of an FEL.

1983-09-19

341

Status of electron accelerators for linear colliders  

Energy Technology Data Exchange (ETDEWEB)

The paper outlines the basic problems concerning creation of electron-positron linear colliders, as well as their present-day status. More details on the question can be found in the proceedings of recent workshops on linear colliders contained in the References. ((orig.)).

1995-02-01

342

Stability of prothrombin and factor VII in freeze-dried plasma  

UK PubMed Central (United Kingdom)

The stability of prothrombin and factor VII was studied using accelerated degradation tests in three preparations of freeze-dried pooled normal plasmas. In a previous report (Brozović, Gurd,...Full Text Available

1971-11-01

343

Solid state and materials research: metal-semiconductor interactions  

International Nuclear Information System (INIS)

This section of the report is concerned with the study of the metallisation, oxidation and doping of materials which are of importance to the micro-electronics industry. The Van de Graaff accelerator and radioactive tracers are used for studying surface and sub-surface behaviour of these materials.

344

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

345

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

346

Proceedings of the 2. international conference on accelerator-driven transmutation technologies and applications  

International Nuclear Information System (INIS)

Technical developments in the construction of high power accelerators have created new research activities on accelerator-driven transmutation technologies (ADTT) with main applications for energy production and nuclear waste transmutation. The on-going research was reported and discussed at the conference. The studies of energy production based on ADTT indicate possible important advantages compared to the present nuclear power reactors. Natural Uranium or Thorium is burned in a subcritical reactor with or without simultaneous incineration and transmutation of nuclear waste. High level radioactive wastes and weapons Plutonium constitute an environmental and proliferation problem. Studies were reported on the possibilities to use ADTT to considerably shorten the life-time and reduce the amount of long-lived radioactive waste in order to decrease the volumes needed for long-term geologic deposition. A panel discussed the ADTT impact on nuclear ...

1996-06-03

347

Probes of Diffusive Shock Acceleration using Gamma-Ray Burst Prompt Emission  

CERN Document Server

The principal paradigm for gamma-ray bursts (GRBs) suggests that the prompt transient gamma-ray signal arises from multiple shocks internal to the relativistic expansion. This paper explores how GRB prompt emission spectra can constrain electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The array of possible high-energy power-law indices in accelerated populations is highlighted, focusing on how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. When encompassing the MeV-band spectral break, fits to BATSE/EGRET burst data indicate that the preponderance of electrons responsible for the prompt emission reside in an intrinsically non-thermal population. This differs markedly from typical populations generated in acceleration simulations; potential resolutions of this conflict such as the action ...

2009-01-01

348

Oxidation of phosphine by iron(III) chloride complexes supported on activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

It has been discovered that iron(III) chloride complexes supported on activated charcoal oxidize phosphine under normal conditions. The process accelerates as the concentration of the chloride ions and the proton acid increases.

1988-06-01

349

Minimizing energy consumption of accelerators and storage ring facilities  

Science.gov (United States)

The discussion of energy usage falls naturally into three parts. The first is a review of what the problem is, the second is a description of steps that can be taken to conserve energy at existing facilities, and the third is a review of the implications of energy consumption on future facilities.

350

Mechanisms of chemotherapy-induced human ovarian aging: double strand DNA breaks and microvascular compromise  

UK PubMed Central (United Kingdom)

The mechanism of chemotherapy-induced acceleration of ovarian aging is not fully understood. We used doxorubicin, a widely used cancer chemotherapeutic, in a variety of in vivo xenograft,...Full Text Available

351

Mechanical work and efficiency in level walking and running  

UK PubMed Central (United Kingdom)

1. The mechanical power spent to accelerate the limbs relative to the trunk in level walking and running, Ẇint, has been measured at various `constant' speeds (3-33...Full Text Available

1977-06-01

352

McMaster PLUS: A Cluster Randomized Clinical Trial of an Intervention to Accelerate Clinical Use of Evidence-based Information from Digital Libraries  

UK PubMed Central (United Kingdom)

BackgroundPhysicians have difficulty keeping up with new evidence from medical research.MethodsWe developed the McMaster Premium...Full Text Available

2006-11-01

353

Mammalian life-span determinant p66shcA mediates obesity-induced insulin resistance  

UK PubMed Central (United Kingdom)

Obesity and metabolic syndrome result from excess calorie intake and genetic predisposition and are mechanistically linked to type II diabetes and accelerated body aging; abnormal nutrient and insulin...Full Text Available

2010-07-27

354

Is the Supernova Remnant RX J1713.7-3946 a Hadronic Cosmic Ray Accelerator ?  

CERN Document Server

The non-thermal supernova remnant RX J1713.7-3946 (G347.3-0.5) has recently been shown to be a site of cosmic ray (CR) electron acceleration to TeV energies (Muraishi et al. 2000). Here we present evidence that this remnant is also accelerating CR nuclei. Such nuclei can interact with ambient interstellar gas to produce high energy gamma-rays via the decay of neutral pions. We associate the unidentified EGRET GeV gamma- ray source 3EG J1714-3857 with a massive (~3*10 5 Mo) and dense (~500 nucleons cm -3) molecular cloud interacting with RX J1713.7-3946. Direct evidence for such interaction is provided by observations of the lowest two rotational transitions of CO in the cloud; as in other clear cases of interaction, the CO(J=2-1)/CO(J=1-0) ratio is significantly enhanced. Since the cloud is of low radio and X-ray brightness, CR electrons cannot be responsible for the bulk of its GeV emission there. A picture thus emerges where both electrons ...

2001-01-01

355

Integrated EM & Thermal Simulations with Upgraded VORPAL Software  

Energy Technology Data Exchange (ETDEWEB)

Nuclear physics accelerators are powered by microwaves which must travel in waveguides between room-temperature sources and the cryogenic accelerator structures. The ohmic heat load from the microwaves is affected by the temperature-dependent surface resistance and in turn affects the cryogenic thermal conduction problem. Integrated EM & thermal analysis of this difficult non-linear problem is now possible with the VORPAL finite-difference time-domain simulation tool. We highlight thermal benchmarking work with a complex HOM feed-through geometry, done in collaboration with researchers at the Thomas Jefferson National Accelerator Laboratory, and discuss upcoming design studies with this emerging tool. This work is part of an effort to generalize the VORPAL framework to include generalized PDE capabilities, for wider multi-physics capabilities in the accelerator, vacuum electronics, plasma processing ...

2011-03-01

356

Increased superoxide in vivo accelerates age-associated muscle atrophy through mitochondrial dysfunction and neuromuscular junction degeneration  

UK PubMed Central (United Kingdom)

Oxidative stress has been implicated in the etiology of age-related muscle loss (sarcopenia). However, the underlying mechanisms by which oxidative stress contributes to sarcopenia have not been thoroughly...Full Text Available

2010-05-01

357

If started early in life, metformin treatment increases life span and postpones tumors in female SHR mice  

UK PubMed Central (United Kingdom)

Hyperglycemia and hyperinsulinemia accelerate both aging and cancer. Antidiabetic biguanides such as metformin decrease glucose, insulin and IGF-1 level. Metformin increases lifespan and prevents cancer...Full Text Available

358

High-energy cosmic-ray nuclei from high- and low-luminosity gamma-ray bursts and implications for multi-messenger astronomy  

CERN Document Server

Gamma-ray burst (GRB) is one of the candidates of high-energy cosmic-ray acceleration sites. They may be also ultra-high-energy (above 3 EeV) cosmic-ray (UHECR) sources. In this paper, we discuss possibilities and implications of high-energy cosmic-ray acceleration in GRBs. (1) First, we show that not only protons but also heavier nuclei can be accelerated up to ultra-high energies in both usual high-luminosity (HL) and low-luminosity (LL) GRBs by using the Geant4. LL GRBs may also make a significant contribution to the observed UHECR flux if they form a distinct population, and we investigate cosmic-ray acceleration in LL GRBs in detail. (2) Second, we discuss implications of the GRB-UHECR hypothesis (and Hypernova-UHECR hypothesis) to cosmic-ray astronomy. HL GRBs and LL GRBs will lead to different source number densities as UHECR sources, so that the determination of the number density of UHECR ...

2008-01-01

359

Genetic screening: The vista of genomic medicine  

UK PubMed Central (United Kingdom)

The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available

2011-01-01

360

Free electron laser experiments using a long pulse induction linac  

International Nuclear Information System (INIS)

The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By smoothing the axial magnetic field profile in the accelerator ...

361

Free electron laser  

International Nuclear Information System (INIS)

Physics and technology of free electron laser (FEL) are reviewed. Mechanisms of stimulated emission in FEL and its present status and future prospects are presented. Electromagnetic wiggler, two stage FEL and so on are also interpreted. Finally, accelerators and wigglers for FEL, recent FEL experiments and FEL applications are noted. (author).

362

Emotions run high in race for collider  

CERN Multimedia

The head of KEK expressed his dismay that SLAC has entered into a collaboration with 3 other US labs and proposes to build the next linear collider at Fermilab, Ilinois. KEK wants the next accelerator to be built somewhere in the Asian Pacific region (1 page).

2001-01-01

363

Development of engineered structural barriers for nuclear-waste packages  

Energy Technology Data Exchange (ETDEWEB)

The development of structural barriers for nuclear waste packages involves selection of candidate materials, their screening by mechanical and corrosion testing, rigorous accelerated testing, and evaluation and comparison with other package elements. This document presents results from work conducted on titanium and ferrous alloys.

1981-09-01

364

Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

The Los Alamos FEL requires tight control of the amplitudes and phases of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. This paper describes the accelerator control scheme and our model and discusses the control of noise in feedback loops, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes are shown and ...

1986-06-02

365

Computing needs of the superconducting super collider  

Energy Technology Data Exchange (ETDEWEB)

Following a brief description of the SSC, the computing needs are discussed for both the accelerator design and the experimentation. The computing power required is considerably beyond that being used at present facilities, and parallel processing is expected to play an important role in supplying these needs.

1984-01-01

366

Compilation of anatomical, physiological and metabolic characteristics for a reference Vietnamese man  

International Nuclear Information System (INIS)

In general, over the course of the time, the phenomenon of acceleration in physical development may be observed, i.e. the children and adults of the next generation are taller and heavier than in former generation. Our data presented in this paper show a regular trend of acceleration in the development on Vietnamese, but the trend is still slow and was mostly probably influenced by our difficulties in a long time of war. It is hoped that, the acceleration in the development may be increased in the future following the economical acceleration of our country, however it is known that the ratio between the length of different parts of human body is a specific characteristic for human race, sex and group age. Therefore we may estimate these ratio for the prolongation of the utilization of our measured physical data. The result of studies on water balance of Vietnamese living in comfortable environment air ...

1998-02-01

367

COSPIN-ANISOTROPY TELESCOPE for ULY - PDS - NASA  

Science.gov (United States)

To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...

368

CHANGE@CERN:Task Force 5 : Restructuring the accelerator sector  

CERN Multimedia

The last of our series on the Task Forces. PS accelerator 'We had a clear mandate, which we could approach in a logical way', explains Steve Myers, Head of SL Division and convenor of Task Force 5, 'To avoid duplication of effort in the accelerator sector through a restructuring that would lead to greater efficiency and flexibility and so release resources for the LHC.' The implementation of all their recommendations is already underway, albeit with different time scales. In 2001 the accelerator sector involved more than 900 staff members in three divisions (LHC, PS and SL) and one unit (AC), working in 141 sections within 34 groups. The first step for the Task Force was to identify major activities within the sector and to set up inter-divisional working groups to review these activities (16 in all), identifying the technologies and the numbers of staff associated with each activity. The working groups were also asked ...

2002-01-01

369

Behavioral genomics of honeybee foraging and nest defense  

UK PubMed Central (United Kingdom)

The honeybee has been the most important insect species for study of social behavior. The recently released draft genomic sequence for the bee will accelerate honeybee behavioral genetics. Although...Full Text Available

2007-04-01

370

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The results show that ...

1987-10-01

371

Advanced water purification facility; Kodo josui shori gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Accelerated oxidation treatment technology is introduced for use in the treatment of poor quality water by ozone injected from the bottom of a pressurized ozone contact tank. Under study as oxidation accelerating processes using ozone center about an ozone/hydrogen peroxide treatment, ozone/UV treatment, ozone/hydrogen peroxide/UV treatment, etc. As the result of testing, important respects in accelerated oxidation are learned, which are stated below. In the ozone-aided treatment, there are some substances, such as chromatic matters, that can be removed more rapidly when in direct contact with gaseous ozone. In this case, the concentration of remnant ozone poses an important problem. In relation to the amount of injected hydrogen peroxide, what is important is the ozone/hydrogen peroxide injection ratio relative to the substance that is to be removed. In the use of UV rays, since the decomposition rate of dissolved ozone is ...

1997-12-19

372

Accelerator Driven Nuclear Energy - The Thorium Option  

ScienceCinema

...global warming problem became undeniable ...as global warming are a number also review they world energy ...global warming temperatures on the models and people take what's called ...? story combat global warming conservation ...

373

Accelerated stability test techniques for middle distillate fuels  

Energy Technology Data Exchange (ETDEWEB)

Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety of test conditions, including temperature, aging time, and oxygen availability. These six test fuels were purposely chosen to ...

1981-01-01

374

Accelerated interleaflet transport of phosphatidylcholine molecules in membranes under deformation.  

UK PubMed Central (United Kingdom)

Biological membranes are lamellar structures composed of two leaflets capable of supporting different mechanical stresses. Stress differences between leaflets were generated during micromechanical experiments...Full Text Available

1996-09-01

375

APEX accelerator cycle for transmutation of long-lived fission wastes  

Energy Technology Data Exchange (ETDEWEB)

Based on preliminary studies, some conclusions can be drawn concerning the Accelerator Fuel Enricher and Fission Product Exterminator (APEX). APEX-1 and APEX-2 systems can destroy TU's, /sup 137/Cs, and /sup 90/Sr at acceptable cost and efficiency. The principal difference between APEX-1 and APEX-2 is the in-reactor and in-circuit inventory of /sup 137/Cs and /sup 90/Sr. Stable and low hazard wastes can be disposed of by burial. Accelerator breeders can effectively sustain a fission reactor economy indefinitely. Military waste can be blended into commercial fuel cycle for transmutation. Accelerator and target technologies appear practical and could be developed in a few years. More detailed studies are needed to better define the technical and economic features of the LAFER and APEX cycles, so that comparative assessments can be made between these cycles, as well as with other transmutation and waste disposal ...

1980-01-01

376

A prospective randomised study on the long-term effect of lumbar fusion on adjacent disc degeneration  

UK PubMed Central (United Kingdom)

The existence and importance of an accelerated adjacent segment disc degeneration (ASD) after lumbar fusion have previously not been demonstrated by RCTs. The objectives of this study were, to determine...Full Text Available

2009-08-01

377

A neurodegenerative disease mutation that accelerates the clearance of apoptotic cells  

UK PubMed Central (United Kingdom)

Frontotemporal lobar degeneration is a progressive neurodegenerative syndrome that is the second most common cause of early-onset dementia. Mutations in the progranulin gene are a major cause of familial...Full Text Available

2011-03-15

378

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

379

Solid state and materials research  

International Nuclear Information System (INIS)

Within about 10 years, microelectronic devices will be made with more than a billion (10"9) electronic components per chip. To implement such a sophisticated technology it will be essential to have a fundamental understanding of the solid state interaction between the different materials in thin film semiconductor structures. This is the main purpose of this research program. Characterization and analysis is carried out mainly by Rutherford backscattering spectrometry and channelling using accelerated nuclear particles from the Van de Graaff accelerator, while radioactive isotopes provide information about interaction mechanisms. 6 figs., 1 ref.

380

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

381

Phase-space analysis of interacting phantom cosmology  

CERN Document Server

We perform a detailed phase-space analysis of various phantom cosmological models, where the dark energy sector interacts with the dark matter one. We examine whether there exist late-time scaling attractors, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. We find that all the examined models, although accepting stable late-time accelerated solutions, cannot alleviate the coincidence problem, unless one imposes a form of fine-tuning in the model parameters. It seems that interacting phantom cosmology cannot fulfill the basic requirement that led to its construction.

2008-01-01

382

Phantom dark energy with varying-mass dark matter particles: acceleration and cosmic coincidence problem  

CERN Document Server

We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

2009-01-01

383

PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.

2006-06-26

384

Operation principle of microsecond plasma opening switches  

International Nuclear Information System (INIS)

Closing and breaking of current in microsecond megaampere plasma opening switches are considered. Conductivity current scaling in the switch due to plasma acceleration by a magnetic piston is discussed and compared with experimental data. Two ways of determining the width of a current channel are taken up. This channel results from the diffusion of the magnetic field in the plane of the piston followed by the convective ejection of the field frozen in the accelerated plasma flow behind the shock wave into the bridge. Based on experimental data, a scaling law for the voltage on the switch according to the switch parameters is derived. The problem of reverse closing, which limits the efficiency of storage energy extraction into the load, is considered

2009-01-01

385

Noninvariance of space/time-scale ranges under a Lorentz transformation and the implications for the study of relativistic interactions  

International Nuclear Information System (INIS)

The summary of this report is: (1) The range of scales #LAMBDA# of a system is not a Lorentz invariant and can vary greatly for some systems. (2) There exists an optimum frame which minimizes #LAMBDA#. (3) We demonstrated speedup of x1000 for PIC simulation of relativistic beam interacting with electron background. (4) It is not in contradiction with the conventional scientific wisdom that 'complexity' is an invariant. (5) We identified three domains of application (laser-plasma acceleration, e-cloud in HEP accelerators, free electron lasers) for which speedup ranging from 2 to 4 orders of magnitude were demonstrated on toy problems.

386

Inverse free electron laser beat-wave accelerator research  

International Nuclear Information System (INIS)

A calculation on the stabilization of the sideband instability in the free electron laser (FEL) and inverse FEL (IFEL) was completed. The issue arises in connection with the use of a tapered (''variable-parameter'') undulator of extended length, such as might be used in an ''enhanced efficiency'' traveling-wave FEL or an IFEL accelerator. In addition, the FEL facility at Columbia was configured as a traveling wave amplifier for a 10-kW signal from a 24-GHz magnetron. The space charge field in the bunches of the FEL was measured. Completed work has been published.

387

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

388

Influence of the humidity on leakage current under accelerated aging of polymer insulating materials  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.

1996-12-31

389

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

390

HINS Linac front end focusing system R&D  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process.

2008-08-01

391

Field emission dark current of technical metallic electrodes  

International Nuclear Information System (INIS)

In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.

2007-04-21

392

Feasibility study on the development of proton accelerator  

Energy Technology Data Exchange (ETDEWEB)

A feasibility on the development of a high energy proton accelerator to be used for R and D in the nuclear field of korea was studied. The proposed one is a proton linac with parameters of about 1 GeV, 20 mA which can supply enough neutrons by the spallation reaction to drive a subcritical reactor. It= is expected to solve the intrinsic problem in the nuclear field such as safety, nuclear waste, proliferation and resource. The study was carried out through a multi-institutional cooperation of universities, institute and industry for a national consensus. 5 refs., 8 tabs., 8 figs. (author)

1996-10-01

393

Development of a motion analysis system using acceleration sensors for tennis and its evaluations  

British Library Electronic Table of Contents (United Kingdom)

The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.

2011-01-01

394

Complex radiation degradation behaviour of PVC materials under accelerated aging conditions  

International Nuclear Information System (INIS)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).

1982-10-01

395

Complex radiation degradation behavior of PVC materials under accelerated aging conditions  

Energy Technology Data Exchange (ETDEWEB)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.

1983-07-01

396

Comparison of Different Methods for Nonlinear Diffusive Shock Acceleration  

CERN Document Server

We provide a both qualitative and quantitative comparison among different approaches aimed to solve the problem of non-linear diffusive acceleration of particles at shocks. In particular, we show that state-of-the-art models (numerical, Monte Carlo and semi-analytical), even if based on different physical assumptions and implementations, for typical environmental parameters lead to very consistent results in terms of shock hydrodynamics, cosmic ray spectrum and also escaping flux spectrum and anisotropy. Strong points and limits of each approach are also discussed, as a function of the problem one wants to study.

2010-01-01

397

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

398

Acceleration Control in Nonlinear Vibrating Systems based on Damped Least Squares  

CERN Document Server

A discrete time control algorithm using the damped least squares is introduced for acceleration and energy exchange controls in nonlinear vibrating systems. It is shown that the damping constant of least squares and sampling time step of the controller must be inversely related to insure that vanishing the time step has little effect on the results. The algorithm is illustrated on two linearly coupled Duffing oscillators near the 1:1 internal resonance. In particular, it is shown that varying the dissipation ratio of one of the two oscillators can significantly suppress the nonlinear beat phenomenon.

2011-01-01

399

Accelerating Nearest Neighbor Search on Manycore Systems  

CERN Document Server

We develop methods for accelerating metric similarity search that are effective on modern hardware. Our algorithms factor into easily parallelizable components, making them simple to deploy and efficient on multicore CPUs and GPUs. Despite the simple structure of our algorithms, their search performance is provably sublinear in the size of the database, with a factor dependent only on its intrinsic dimensionality. We demonstrate that our methods provide substantial speedups on a range of datasets and hardware platforms. In particular, we present results on a 48-core server machine, on graphics hardware, and on a multicore desktop.

2011-01-01

400

Accelerated-aging tests for predicting radiation degradation of organic materials  

Energy Technology Data Exchange (ETDEWEB)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-03-01

401

Accelerated-aging tests for predicting radiation degradation of organic materials  

International Nuclear Information System (INIS)

Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.

1984-01-01

402

Accelerated aging of EPDM and butyl elastomers  

Energy Technology Data Exchange (ETDEWEB)

This study was composed of three parts: a post cure study to optimize final properties of an ethylene-propylene-diene (EPDM) formulation, an accelerated aging study to compare the stress relaxation behavior of a butyl and an EPDM elastomer under compression, and a cursory evaluation of a new 70 Shore A EPDM. The optimum postcure for the EPDM was found to be 2 to 4 hours at 182{degrees}C in a vacuum. The EPDM was also shown to have superior aging characteristics compared to the butyl and is recommended for use instead of the butyl material. The physical properties for new 70 Shore A EPDM are satisfactory, and the stress relaxation behavior was only slightly inferior to the other EPDM.

1996-06-01

403

A comprehensive, numerical model of electro-thermal propulsion  

Science.gov (United States)

A computer model of an electrothermal accelerator has been developed which applies to the plasma generator as well as the gun barrel, and it for the first time allows study of the interdependent physical processes in both components simultaneously. The code comprises a 2D transient description of the plasma arc, a 2D, two-phase interior ballistics module, and a preprocessor delivering the required plasma physical data. Some results on the flow field, pressure and temperature in a typical accelerator are presented, and probable limitations on the performance of such a system are discussed. The code is to be applied to different concepts of electrothermal chemical guns.

1993-01-01

404

Change of the mass of an accelerated charge as a dynamic manifestation of the clock paradox  

Energy Technology Data Exchange (ETDEWEB)

Mass shift of accelerated charges-sources of a massive vector and massive scalar fields, are considered in an approximation which is classical with respect to the charge motion but quantum with respect to their interaction with their proper field. For uniformly accelerated charges the mass shifts are expressed in terms of cylindrical functions of the quantum parameter ..mu..c/sup 3//h/2..pi..w/sub 0/ which is the ratio of the mass ..mu.. of the proper field quanta to the charge acceleration w/sub 0/. For finite positive values of the parameter both the imaginary and real parts of the shifts are nonvanishing and negative. For ..mu -->..0 the real part of the mass shift of a vector charge tends to the classical value -..cap alpha..h/2..pi..w/sub 0//2c/sup 3/ obtained earlier, thereas that of the scalar charge tends to zero. These and other properties of the shifts as functions of ..mu.. are studied by taking into account ...

1982-05-01

405

Accelerator technology program. Progress report, April-December 1978  

Science.gov (United States)

This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and results on emittance ...

1980-05-01

406

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly due to the contribution to viscosity from polymer entanglement becoming dominant over that from mean ...

2010-04-15

407

The Differentially Expressed Genes by Radiotherapy in the Patients with Uterine Cervix Cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA fragments. Expression pattern of down-regulated clone was examined using RT-PCR in ...

2001-12-15

408

Role of radiation therapy in the management of nonmetastatic Ewing's sarcoma of bone. Report of the intergroup Ewing's sarcoma study  

International Nuclear Information System (INIS)

The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in detail. Distant ...

409

Radiation therapy for gastrointestinal lymphomas: indications and techniques  

International Nuclear Information System (INIS)

Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...

410

Prognostic factors in the treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

From 1981 up to February 1985, a total of 93 protocol patients entered the study CESS 81. The protocol recommended an initial 18-week period of polychemotherapy (VACA) followed by local therapy and two additional cycles of chemotherapy. Local therapy consisted either of radical surgery or of incomplete resection plus postoperative irradiation with 36 Gy or of radiotherapy alone (46 and 60 Gy). Centrally located lesions were always irradiated with 60 Gy. This article summarizes the data after 5 years. Data of 93 patients were analysed in October 1986 after a median follow-up of 37 months. The projected 5-year survival is 50%. The relapse rate was 42%, distant relapses occurred in 19%, local (plus distant) relapses in 23%. Most of the relapses occurred during the first 3 years of observation. Failure rate was high in patients undergoing irradiation alone (44%). Initial tumour mass (> 100 ml) and histopathologic response to initial chemotherapy were identified as ...

411

Primary spinal epidural extraosseous Ewing's sarcoma: Report of five cases and literature review  

International Nuclear Information System (INIS)

Ewing's sarcoma is the most common malignant bone tumour occurring in children and adolescents and exists in two different clinico pathological entities: osseous Ewing's sarcoma (OES) and extraosseous Ewing's sarcoma (EES). Five cases of primary epidural EES are described, which presented with non-specific symptoms leading to a long diagnostic delay. The median age at diagnosis was 22 years (range 13-36 years). The median diagnostic delay was 3 months. All patients had one or more neurological deficits. All underwent surgical exploration with a laminectomy and partial resection followed by adjuvant radiotherapy to a dose of 46-50 Gy and chemotherapy with VAC (vincristine, adriamycin and cyclophosphamide) alternating with ICE (ifosphamide, cisplatin and etoposide) for at least six cycles. The mean follow-up period is 21.2 months (range 11-32 months). Four of the five patients achieved a complete remission and are disease free at the time of writing this report. Two ...

2001-08-01

412

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...

2006-01-15

413

Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated X-ray beams vs. intensity-modulated proton beams  

International Nuclear Information System (INIS)

Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for all targets and OAR with both treatment ...

2000-07-01

414

Impact of more intensive written information in patients having radical radiation therapy: Results of a prospective randomized phase III trial  

International Nuclear Information System (INIS)

Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of radiotherapy. A second ...

2010-08-01

415

Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal ...

2009-02-21

416

Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning  

International Nuclear Information System (INIS)

This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density matrix. It is ...

2003-09-07

417

Ewing's sarcoma treatment in Scandinavia 1984-1990. Ten-year results of the Scandinavian sarcoma group protocol SSGIV  

International Nuclear Information System (INIS)

A report on the long-term follow up of the first cooperative Scandinavian Sarcoma Group study in Ewing's sarcoma of bone is presented. Fifty-two previously untreated patients entered the study between 1984 and 1990. Half of the tumors were located in the extremities and one quarter in the pelvis. The combined modality treatment consisted of 5 cycles of chemotherapy - including vincristine, methotrexate, doxorubicin, cyclophosphamide, bleomycin and dactinomycin. The first two cycles were followed by local resection or amputation in 35 patients and by radiotherapy alone in 17 patients. When surgery was not performed, was incomplete or yielded poor margins radiotherapy was given at a dose of 40-60 Gy. Local tumor relapses developed in 10 patients and in all but one patient were accompanied by metastatic disease. Five patients had metastasis at diagnosis and distant metastases developed after primary treatment in 27 patients after a median of 14 ...

418

Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients  

Energy Technology Data Exchange (ETDEWEB)

Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...

2010-10-15

419

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The ...

2003-07-21

420

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases  

International Nuclear Information System (INIS)

This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with ?4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10?20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a contrast-enhanced brain CT was reviewed. ...

2009-09-01

421

Combined chemotherapy and radiotherapy: from biology to bed-side  

International Nuclear Information System (INIS)

Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle redistribution. In clinical ...

422

Clinical utility of serum ferritin levels in patients with malignant tumors treated by radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for ...

1983-10-01

423

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

International Nuclear Information System (INIS)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT investigations were planned to ...

2005-03-01

424

An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy  

International Nuclear Information System (INIS)

Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition dose model is used to compute dose during each iteration. Results: Two clinically ...

1995-07-15

425

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...

2010-10-15

426

A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy  

International Nuclear Information System (INIS)

Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information. Conclusions: ...

2006-06-01

427

Fermilab Steering Group Report  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the ...

2007-01-01

428

Sandia LSI accelerated aging and data acquisition techniques  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the Microelectronic Evaluation Laboratory at Sandia is to develop a program for evaluating CMOS LSI (complementary metal oxide silicon - large scale integrated) technology devices which are being used for the first time in a weapon system. These evaluations are based on accelerated aging studies and electrical tests to determine the reliability and life of the devices. In accelerated aging, specific, controlled stresses are applied to the device to accelerate time-to-failure. Data are used tin mathematical models to estimate life in acutal use. The stresses used for this technology are temperature and voltage. The devices are stored at temperatures with or without voltage applied (steady-state or cyclical) and periodically tested until at least 50% failures are encountered. Since most current technologies use epoxy-die-attachment, aging temperatures must be under 200/sup 0/C. This delays device failure, and a ...

1980-04-01

429

Integrated Numerical Experiments (INEX) and the Free-Electron Laser Physical Process Code (FELPPC)  

International Nuclear Information System (INIS)

The strong coupling of subsystem elements, such as the accelerator, wiggler, and optics, greatly complicates the understanding and design of a free electron laser (FEL), even at the conceptual level. To address the strong coupling character of the FEL the concept of an Integrated Numerical Experiment (INEX) was proposed. Unique features of the INEX approach are consistency and numerical equivalence of experimental diagnostics. The equivalent numerical diagnostics mitigates the major problem of misinterpretation that often occurs when theoretical and experimental data are compared. The INEX approach has been applied to a large number of accelerator and FEL experiments. Overall, the agreement between INEX and the experiments is very good. Despite the success of INEX, the approach is difficult to apply to trade-off and initial design studies because of the significant manpower and computational requirements. On the other hand, INEX provides a base ...

1990-07-01

430

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...

1998-11-06

431

(Evaluation of the high intensity plasma sputer negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams)  

Energy Technology Data Exchange (ETDEWEB)

A working visit was made to the National Laboratory for High Energy Physics, Tsukuba, Japan, during the time periods May 16, 1988--June 15, 1988 for the purposes of further evaluation of the high intensity plasma sputter negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams. During the visit, the traveler worked in collaboration with Japanese scientists in installing and testing of the source on the University of Tsukuba tandem electrostatic accelerator injector. During the course of preliminary testing of the ion source and prior to actual injection into the accelerator, sparking began in one or more tube sections, which ultimately led to the decision to replace the damaged tube sections. This problem led to postponement of the scheduled tandem accelerator tests. The traveler attended the Seventh ...

1988-07-06

432

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

433

rf system for the Los Alamos free-electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. ...

1983-01-01

434

rf system for the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each ...

1983-03-21

435

Tridimensional analysis of the accelerator transmutation waste system  

International Nuclear Information System (INIS)

The Accelerator Transmutation Waste System is under development at the Los Alamos National Laboratory. The goal is to perform an independent verification of the feasibility of actinide and long-lived fission product burning in this system. The authors' work is divided into five tasks: (a) production of an actinide and long-lived fission product cross section library from JEF 2.2; (b) simulation using MCNP and KENO IV Monte Carlo codes, of the Accelerator Transmutation Waste System configurations existing in literature; (c) validation of HETC Monte Carlo code (production of spallation source); (d) validation of the cross sections by comparison of Keff and reaction rate results, calculated with MNCP and KENO IV, with experimental benchmarks and intercomparison between the authors' calculations of a PWR unit cell and the computations carried out with various codes and cross section libraries (NEACRP critically group data); and (e) simulation of ...

436

The compact linear collider CLIC  

CERN Document Server

A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A new test facility is being built at CERN for this purpose with ...

2004-01-01

437

The RF system for the Los Alamos free electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s ...

438

Solar system constraints on a Rindler-type extra-acceleration from modified gravity at large distances  

CERN Document Server

We analytically work out the orbital effects caused by a Rindlertype extra-acceleration ARin which naturally arises in some recent models of modified gravity at large distances. In particular, we focus on the perturbations induced by it on the two-body range {\\rho} and range-rate {\\rho}\\cdot which are commonly used in satellite and planetary investigations as primary observable quantities. The constraints obtained for ARin by comparing our calculations with the currently available range and range-rate residuals for some of the major bodies of the solar system, obtained without explicitly modeling ARin, are 1 - 2 \\times 10-13 m s-2 (Mercury and Venus), 1 \\times 10-14 m s-2 (Saturn), 1 \\times 10-15 m s-2 (Mars), while for a terrestrial Rindler acceleration we have 5 \\times 10-16 m s-2 (Moon). Another approach which could be followed consists of taking into account ARin in re-processing all the available data sets with accordingly modified ...

2010-01-01

439

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion beams have been developed. Large plasma sources, the method of generating negative ions and the extraction of ...

1993-12-01

440

RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS  

International Nuclear Information System (INIS)

Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with ...

2010-10-10

441

Progress at LAMPF, 1992--1993  

Energy Technology Data Exchange (ETDEWEB)

This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP Division, which led to the loss of a large number of key people to positions elsewhere in the Laboratory. ...

1994-07-25

442

Numerical testing of hypotheses for the recent thinning and acceleration of Greenland outlet glaciers  

Environmental Research Database

ObjectivesThe overall scientific aim of this project is, through development of an appropriate numerical modelling tool, to identify and investigate the mechanisms that control the current observed rapid thinning and acceleration of Greenland outlet glaciers and to investigate their likely future behaviour in the context of climate warming. This aim is addressed through the four major specific objectives below. These objectives build on each and therefore the order of priority is driven by the order in wh [continued...]DescriptionCurrently, the Greenland ice sheet is undergoing rapid changes in the coastal regions which have been attributed to a general warming trend to the regions climate over the last decade. Several of the narrow and fast flowing outlet glaciers that drain the ice sheet into the sea are observed to have accelerated their flow and thinned. For instance, Jakobshavn Isbrae on the West coast of Greenland has almost doubled its ...

2008-01-31

443

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and ...

1994-12-31

444

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and ...

1994-05-01

445

Investigations of Pulsed Plasma Streams Generated by 'Prosvet' device Operated with Different Gases  

International Nuclear Information System (INIS)

The paper presents the investigations of plasma streams generated by pulsed plasma gun 'Prosvet' operated with different gases: krypton (m=84) and helium (m=4). Contour parameters of working gas spectral lines (full intensities and half-widths) are used for determination of spatial distributions of the electron density and temperature. Temporal distributions of the spectral lines intensities (both neutrals and ions of working gas), impurity spectral lines and continuum intensities are analyzed. Plasma stream velocity was estimated by time-of-flight method between two monochromators (MUM) connected with photo-multiplier. longitudinal distributions of the plasma pressure for different time moments and varied distances from the accelerator output have been used for investigation of the plasma stream dynamics and study the plasma compression in the focus region for different operational regimes of plasma accelerator. Experiments show that operation ...

2006-01-01

446

Free electron laser and accelerator  

International Nuclear Information System (INIS)

The present report addresses several aspects of the free electron laser (FEL) and accelerator, including their features, potentials, mechanisms, beams emitted from undulator, FEL produced by helical mangnetic field, major problems with FEL, etc. In FEL, relativistic electron beams interact with an electromagnetic field with periodically changing intensity to produce coherent electromagnetic waves with variable wavelength. The capability of varying its wavelength represents the greatest advantage over conventional lasers. Any periodic magnetic field can serve as a wiggler. A wiggler can be used both in an amplifier and oscillator. A periodic magnetic field used may be either of a parallel type or of a helical type. The polarization of emitted beams depends on the shape of the magnet regardless of whether its field is parallel or helical. An equation is derived in the report which expresses the wavelength of an electromagnetic wave produced by an undulator. An ...

1988-08-01

447

Elise plans and progress  

International Nuclear Information System (INIS)

Elise is a heavy ion induction linear accelerator that will demonstrate beam manipulations required in a driver for inertial fusion energy. With a line charge density similar to that of heavy ion drivers, Elise will accelerate a #>=# 1 gs beam pulse of K"+ ions from an initial energy of 2 MeV to a final energy #>=# 5 MeV. In the present design, the Elise electrostatic quadrupoles (ESQ) will have a 2.33 cm radius aperture operating at #+-#59 kV. The half-lattice periods range from 21 cm to 31 cm. The entire machine will be approximately 30 m long, half of that is the induction accelerator and the remaining half is the injector (including the Marx generator) and the matching section. Elise will be built in a way that allows future expansion into the full ILSE configuration, therefore it will have an array of four ESQ focusing channels capable of transporting up to a total of 3.2 A of beam current. Elise will also have ...

1995-09-06

448

Effect of sulfur or hydrogen sulfide on initial stage of coal liquefaction in tetralin; Sekitan ekika shoki katei ni okeru io to ryuka suiso no hatasu yakuwari  

Energy Technology Data Exchange (ETDEWEB)

It is well known that the solubilization of coal can be accelerated by adding sulfur or hydrogen sulfide during direct liquefaction of difficult coals. From the studies of authors on the coal liquefaction under the conditions at rather low temperatures between 300 and 400{degree}C, liquefaction products with high quality can be obtained by suppressing the aromatization of naphthene rings, but it was a problem that the reaction rate is slow. For improving this point, results obtained by changing solvents have been reported. In this study, to accelerate the liquefaction reaction, Illinois No.6 coal was liquefied in tetralin at temperature range from 300 to 400{degree}C by adding a given amount of sulfur or hydrogen sulfide at the initial stage of liquefaction. The addition of sulfur or hydrogen sulfide provided an acceleration effect of liquefaction reaction at temperature range between 300 and 400{degree}C. The addition of ...

1996-10-28

449

Distributed Grating-Assisted Coupler for Optical All-Dielectric Electron Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A Bragg waveguide consisting of multiple dielectric layers with alternating index of refraction becomes an excellent option to form electron accelerating structure powered by high power laser sources. It provides confinement of a synchronous speed-of-light mode with extremely low loss. However, laser field can not be coupled into the structure collinearly with the electron beam. There are three requirements in designing input coupler for a Bragg electron accelerator: side-coupling, selective mode excitation, and high coupling efficiency. We present a side coupling scheme using a distributed grating-assisted coupler to inject the laser power into the waveguide. Side coupling is achieved by a grating with a period on the order of an optical wavelength. The phase matching condition results in resonance coupling thus providing selective mode excitation capability. The coupling efficiency is limited by profile matching between the outgoing beam and ...

2005-09-23

450

Design study of longitudinal dynamics of the drive beam in 1 TeV relativistic klystron two-beam accelerator  

International Nuclear Information System (INIS)

In this paper the authors present a design study on the longitudinal dynamics of a relativistic klystron two-beam accelerator (RK-TBA) scheme which has been proposed as a power source candidate for a 1 TeV next linear collider (NLC). They address the issue of maintaining stable power output at desired level for a 300-m long TBA with 150 extraction cavities and present their simulation results to demonstrate that it can be achieved by inductively detuning the extraction cavities to counter the space charge debunching effect on the drive beam. They then carry out simulation study to show that the beam bunches desired by the RK-TBA can be efficiently obtained by first chopping an initially uniform beam of low energy into a train of beam bunches with modest longitudinal dimension and then using the open-quotes adiabatic captureclose quotes scheme to bunch and accelerate these beam bunches into tight bunches at the operating energy of the drive ...

1994-11-07

451

Degradation mechanisms and accelerated aging test design  

Energy Technology Data Exchange (ETDEWEB)

The fundamental mechanisms underlying the chemical degradation of polymers can change as a function of environmental stress level. When this occurs, it greatly complicates any attempt to use accelerated tests for predicting long-term material degradation behaviors. Understanding how degradation mechanisms can change at different stress levels facilitates both the design and the interpretation of aging tests. Oxidative degradation is a predominant mechanism for many polymers exposed to a variety of different environments in the presence of air, and there are two mechanistic considerations which are widely applicable to material oxidation. One involves a physical process, oxygen diffusion, as a rate-limiting step. This mechanism can predominate at high stress levels. The second is a chemical process, the time-dependent decomposition of peroxide species. This leads to chain branching and can become a rate-controlling factor at lower stress levels involving time-scales ...

1985-01-01

452

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is ...

1992-03-16

453

CLUSTER: a high frequency H-mode coupled cavity linac for low and medium energies  

CERN Document Server

We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER, which stands for "Coupled-cavity Linac USing Transverse Electric Radial field". In order to compare the performance of this structure with other hadrontherapy linac designs involving high frequencies, a conceptual study has been performed for an operating frequency of 3 GHz. Moreover a proof of principle has been obtained through RF measurements on a prototype operating at 1 GHz. An accelerator complex using a CLUSTER linac is also considered for protontherapy purposes. The whole complex is called cyclinac and is composed of a ...

2006-01-01

454

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating ...

455

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of ...

456

Accelerated aging tests with a resid hydrotreating catalyst  

Energy Technology Data Exchange (ETDEWEB)

The deactivation rate of a resid hydrotreating catalyst is determined by a complex set of factors involving both chemical and physical changes in the catalyst structure. The various chemical changes that are associated with resid conversion involve thermal and catalytic steps of relatively large molecular weight species with the overall rates significantly affected by mass transfer limitations. The deposition of coke and the variation in the effective promoter level by the accumulation of metals deposited from the resid are the principal factors governing deactivation. The relative importance of mass transfer restrictions on activity and catalyst deactivation can be observed in studies where the average pore diameter of the catalyst has been varied. Several models have been proposed to characterize the deactivation of resid hydroprocessing catalysts. In this paper, the authors discuss some accelerated aging tests with a relatively large pore commercial ...

1987-04-01

457

Accelerated aging tests of liners for uranium mill tailings disposal  

Energy Technology Data Exchange (ETDEWEB)

This document describes the results of accelerated aging tests to determine the long-term effectiveness of selected impoundment liner materials in a uranium mill tailings environment. The study was sponsored by the US Department of Energy under the Uranium Mill Tailings Remedial Action Project. The study was designed to evaluate the need for, and the performance of, several candidate liners for isolating mill tailings leachate in conformance with proposed Environmental Protection Agency and Nuclear Regulatory Commission requirements. The liners were subjected to conditions known to accelerate the degradation mechanisms of the various liners. Also, a test environment was maintained that modeled the expected conditions at a mill tailings impoundment, including ground subsidence and the weight loading of tailings on the liners. A comparison of installation costs was also performed for the candidate liners. The laboratory testing and cost ...

1981-11-01

458

Varying-G Cosmology with Type Ia Supernovae  

CERN Document Server

The observation that Type Ia supernovae are fainter than expected given their red shifts has led to the conclusion that the expansion of the universe is accelerating. The widely accepted hypothesis is that this acceleration is caused by a cosmological constant or, more generally, some dark energy field that pervades the universe. This hypothesis presents a challenge to physics so severe that one is motivated to explore alternative explanations. In this paper, we explore whether the data from Type Ia supernovae can be explained with an idea that is almost as old as that of the cosmological constant, namely, that the strength of gravity varies on a cosmic timescale. This topic is an ideal one for investigation by an undergraduate physics major because the entire chain of reasoning from models to data analysis is well within the mathematical and conceptual sophistication of a motivated undergraduate.

2009-01-01

459

The transient performance during acceleration in a passenger car diesel engine at the lower temperature operation  

Energy Technology Data Exchange (ETDEWEB)

Diesel passenger car is superior to gasoline engine car in the fuel economy, but it has some defects to improve: noise, startability, particulate and transient performance, etc. Among these problems, this paper presents particularly transient performance in a diesel engine and clarifies the causes of its decline at lower temperature operation. As the results, it is found that the transient torque at the early stage of acceleration is only 50% at -20/sup 0/C, and that when coolant temperature went up to 20/sup 0/C, the transient torque approaches to that of the warmed up engine. The transient response become worse with retarding the injection timing and with decreasing the engine speed. On the other hand, since the normal response is not obtained despite using high cetane number fuel, main cause of the inferior transient torque is not the poor combustion, but the increase of friction or cooling loss.

1985-01-01

460

The Nuclear Outflow in NGC 2110  

CERN Document Server

We present a HST/STIS spectroscopic and optical/radio imaging study of the Seyfert NGC 2110 aiming to measure the dynamics and understand the nature of the nuclear outflow in the galaxy. Previous HST studies have revealed the presence of a linear structure in the Narrow-Line Region (NLR) aligned with the radio jet. We show that this structure is strongly accelerated, probably by the jet, but is unlikely to be entrained in the jet flow. The ionisation properties of this structure are consistent with photoionisation of dusty, dense gas by the active nucleus. We present a plausible geometrical model for the NLR, bringing together various components of the nuclear environment of the galaxy. We highlight the importance of the circum-nuclear disc in determining the appearance of the emission line gas and the morphology of the jet. From the dynamics of the emission line gas, we place constraints on the accelerating mechanism of the outflow and discuss ...

2010-01-01

461

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

462

TeV gamma-rays from the Northern sky pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.

2005-12-01

463

Radioisotopes for radioimmunodetection (RAID) and radioimmunotherapy (RAIT)---current and new perspectives  

Energy Technology Data Exchange (ETDEWEB)

In this paper the availability and properties of radioisotopes for both radioimmunodiagnosis (RAID) and radioimmunotherapy (RAIT) are discussed. Examples are provided for radioisotopes available via direct production in nuclear reactors and accelerators or as daughters obtained from radionuclide generator systems whose parents are either reactor or accelerator produced. Important factors which must be considered for the use of a particular radioisotope include availability, the physical half-life and decay properties, and chemical versatility for protein attachment. Although both direct'' and indirect'' methods are available for attachment of radioisotopes to antibodies, this broad field of research is not reviewed in detail. Practical issues related to the availability and use of a variety of radionuclides are described. 47 refs., 5 tabs.

1991-01-01

464

Quantum corrections to the Larmor radiation formula in scalar electrodynamics  

CERN Document Server

We use the semi-classical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the non-relativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be non-local in time in contrast to the classical approximation.

2009-01-01

465

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

466

Proposal for a free electron laser driven by the 7 MeV NILPRP linac  

International Nuclear Information System (INIS)

The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)

467

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

468

Probing the origin of inertia behind spacetime deformation  

CERN Document Server

To investigate the origin and nature of inertia, we introduce a new concept of hypothetical 2D, so-called, "master-space" (MS), subject to certain rules. The MS, embedded in the background 4D-spacetime, is an indispensable individual companion to the particle of interest, without relation to every other particle. We argue that a deformation/(distortion of local internal properties) of MS is the origin of inertia. With this perspective in sight, we construct the alternative relativistic theory of inertia (RTI), which allows to compute the relativistic inertial force acting on an arbitrary point-like observer due to its "absolute acceleration". We go beyond the hypothesis of locality with an emphasis on distortion of MS, which allows to improve essentially the standard metric and other relevant geometrical structures related to the noninertial reference frame of an arbitrary accelerated observer. We compute the inertial force exerted on the ...

2011-01-01

469

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction mode of polyester-monomer systems in wood ...

1981-01-01

470

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

International Nuclear Information System (INIS)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction mode of polyester-monomer systems in wood ...

1980-09-01

471

Particulate kinematic simulations of debris avalanches: interpretation of deposits and landslide seismic signals of Mount Saint Helens, 1980 May 18:  

British Library Electronic Table of Contents (United Kingdom)

SUMMARY We construct a new class of granular landslide models in which avalanches are simulated with large numbers of independent particles moving under the influence of topographically derived gravitational and centripetal acceleration. Concurrently, the particles suffer deceleration due to basal and dynamic friction. The novel aspect of the calculation is that complex particle-to-particle interactions, fluctuating basal contacts, and unresolved topographic roughness within and below the deforming flow are mimicked by random perturbations in along-track and cross-slope acceleration. We apply the method to the 1980 May 18 Mount Saint Helens debris avalanche by constraining the initial geometry and structure of the slide mass from geological data, and the initial failure sequence from eyewi...

2006-01-01

472

Los Alamos Advanced Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.

1991-01-01

473

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.

2006-01-01

474

Linac Coherent Light Source Experiments Commence  

British Library Electronic Table of Contents (United Kingdom)

The Linac Coherent Light Source [1] (LCLS) at SLAC National Accelerator Laboratory is preparing for the arrival of its first scientific users in the fall of 2009. LCLS is the world's first free-electron in the spectral range 800-8,000 eV, producing intense, sub-picosecond pulses of Xrays with very high spatial coherence. The accelerator facility has been commissioned in stages, beginning in April 2007 [2] with the injector linac and culminating in December 2008 [3] with the first transport of electrons through the complete beam path. On April 10, 2009, the LCLS Project team was rewarded for years of planning, design, construction, and checkout with a dream-come-true: as undulators were placed on the beam path one-by-one, the laser simply turned on without drama in the course of one hour [4...

2009-01-01

475

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.

1996-12-31

476

Future directions in controlling the LAMPF-PSR Accelerator Complex at Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Four interrelated projects are underway whose purpose is to migrate the LAMPF-PSR Accelerator Complex control systems to a system with a common set of hardware and software components. Project goals address problems in performance, maintenance and growth potential. Front-end hardware, operator interface hardware and software, computer systems, network systems and data system software are being simultaneously upgraded as part of these efforts. The efforts are being coordinated to provide for a smooth and timely migration to a client-sever model-based data acquisition and control system. An increased use of the distributed intelligence at both the front-end and operator interface is a key element of the projects. 2 refs., 2 figs.

1991-01-01

477

Energy saver A-sector power test results  

Energy Technology Data Exchange (ETDEWEB)

The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.

1982-09-15

478

Embedded systems for vacuum control at PEFP  

International Nuclear Information System (INIS)

Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.

2005-05-26

479

Electron yield enhancement in a laser wakefield accelerator driven by asymmetric laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The effect of asymmetric laser pulses on electron yield from a laser wakefield accelerator has been experimentally studied using > 10{sup 19} cm{sup -3} plasmas and a 10 TW, > 45 fs, Ti:Al{sub 2}O{sub 3} laser. Laser pulse shape was controlled through non-linear chirp with a grating pair compressor. Pulses (76 fs FWHM) with a steep rise and positive chirp were found to significantly enhance the electron yield compared to pulses with a gentle rise and negative chirp. Theory and simulation show that fast rising pulses can generate larger amplitude wakes that seed the growth of the self-modulation instability and that frequency chirp is of minimal importance for the experimental parameters.

2002-08-01

480

Effect of material aging on parachute pack life: a synopsis of Sandia National Laboratories studies  

Energy Technology Data Exchange (ETDEWEB)

A systematic study of the effects of environmental factors on nylon 66 and Kevlar 29 strength degradation in parachute components is being conducted at Sandia National Laboratories. It includes: (1) accelerated aging studies in air, inert environments, humidity, ozone, and smog; (2) a 25-year surveillance program of parachutes in a variety of natural climatic environments; (3) moisture absorption as a function of humidity; (4) effects of surface coatings normally applied to parachutes; and (5) development of nondestructive evaluation techniques which can be used to map mechanical properties over the entire parachute surface. The accelerated aging and moisture absorption studies show that air, humidity, and smog contribute to degradation. Chemiluminescence, gas chromatographic pyrograms, and uv spectroscopy show promise as nondestructive evaluation techniques.

1984-01-01

481

Developments of linacs for ADTT in the USA  

Energy Technology Data Exchange (ETDEWEB)

Interesting developments in linear accelerators have been attained over the past 45 years. The status of linear accelerators and future possibilities are described in context of demanding applications and technology maturity. Features of industrial or `factory`-type applications are high availability, economic operations, low investment cost and ease of running a facility. All features have been demonstrated in one manner or another at large operating facilities for the research community; within a different context that has been argued in the past to be not as demanding as for `factory` installation. In addition, comments are made relative to intense beam power levels and choices that can be made for power levels below 10 MW, on the assumption that a cw beam is required. 1 fig., 1 tab.

1997-09-01

482

Dating Studies of Elephant Tusks Using Accelerator Mass Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

A new method for determining the year of birth, the year of death, and hence, the age at death, of post-bomb and recently deceased elephants has been developed. The technique is based on Accelerator Mass Spectrometry radiocarbon analyses of small-sized samples extracted from along the length of a ge-line of an elephant tusk. The measured radiocarbon concentrations in the samples from a tusk can be compared to the {sup 14}C atmospheric bomb-pulse curve to derive the growth years of the initial and final samples from the tusk. Initial data from the application of this method to two tusks will be presented. Potentially, the method may play a significant role in wildlife management practices of African national parks. Additionally, the method may contribute to the underpinnings of efforts to define new international trade regulations, which could, in effect, decrease poaching and the killing of very young animals.

2002-10-03

483

Cosmological dynamics on the brane  

CERN Document Server

In Randall-Sundrum-type brane-world cosmologies, the dynamical equations on the three-brane differ from the general relativity equations by terms that carry the effects of imbedding and of the free gravitational field in the five-dimensional bulk. Instead of starting from an ansatz for the metric, we derive the covariant nonlinear dynamical equations for the gravitational and matter fields on the brane. The local energy-momentum corrections are significant only at very high energies, and in this regime we show that fluid world-lines have a non-gravitational acceleration off the brane. The imprint on the brane of the nonlocal gravitational field in the bulk is more subtle, and we provide a careful decomposition of this effect. The nonlocal energy density determines the tidal acceleration in the off-brane direction, and can oppose singularity formation via the generalized Raychaudhuri equation. Unlike the nonlocal energy density and flux, the ...

2000-01-01

484

Cosmic time dilation: The clock paradox revisited  

Energy Technology Data Exchange (ETDEWEB)

The relativistic time dilation is reviewed in a cosmological context. We show that a clock or twin paradox does not arise if cosmic time is properly taken into account. The receding galaxy background provides a unique frame of reference, and the proper times of geodesic as well as accelerated observers can be linked to the universal cosmic time parameter. This suggests to compare the proper time differentials of the respective observers by determining their state of motion in the galaxy grid. In this way, each observer can figure out whether his proper time is dilated or contracted relative to any other. In particular one can come to unambiguous conclusions on the aging of uniformly moving observers, without reference to asymmetries in measurement procedures or accelerations they may have undergone.

2004-05-01

485

Corrosion of gold bridgewire in electronic components  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion product and degradation of the plastic header.

1986-01-01

486

Construction and development of a UV free electron laser under the cooperation of Nihon U, KEK, PNC, ETL and Tohoku U  

Energy Technology Data Exchange (ETDEWEB)

The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.

1995-12-31

487

Conceptual design of industrial free electron laser using superconducting accelerator  

International Nuclear Information System (INIS)

Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.

1995-08-21

488

Chromosomal mapping of excessive physical activity in mice in response to a restricted feeding schedule  

British Library Electronic Table of Contents (United Kingdom)

Excessive physical activity plays an important role in the progression of anorexia nervosa (AN) by accelerating weight loss during dietary restriction. To search for mechanisms underlying this trait, a panel of mouse chromosome substitution strains derived from C57BL/6J and A/J strains was exposed to a scheduled feeding paradigm and to voluntary running wheel (RW) access. Here, we showed that A/J chromosomes 4, 12 and 13 contribute to the development of a disrupted RW activity in response to daily restricted feeding. This pattern is characterized by intense RW activity during the habitual rest phase and leads to accelerated body weight loss. Regions on mouse chromosomes 4, 12 and 13 display homology with regions on human chromosomes linked with anxiety and obsessionality in AN cohorts. The...

2010-01-01

489

Characteristics of the 18 MeV medical linear accelerator 'NELAC-1018', 2. Electron beams  

Energy Technology Data Exchange (ETDEWEB)

The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.

1983-11-01

490

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

491

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

492

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

493

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

494

A new strategy of counterattacking anti-satellite based on motion camouflage  

Science.gov (United States)

Motion Camouflage (MC) is illuminated as a novel strategy in counterattacking anti-satellite by way of stealth trajectory scheduling. The dynamics model of MC in space is developed and a quadratic function with three boundary constraints is employed for trajectory determination. Based on the model a scenario is set to run the simulation. The results indicate given the designed acceleration input, the predator will be moved following a prescribed route, which precisely locates the predator between two objects at each time instant. In the last approaching phase, the motion is achieved with a big bumping rate which guarantees the power of this striking. Methods for deriving minimum fuel cost in the fixed approaching duration and the minimum approaching duration in limited acceleration input are proposed and are verified in the simulation. At last, camouflage is recognized as a multi-faceted affair, in which stealth trajectory design is considered ...

2010-08-01